bergen-power pipe supports, inc.
Transcription
bergen-power pipe supports, inc.
BERGEN-POWER PIPE SUPPORTS, INC. A wholly owned subsidiary of The Paterson Group, Inc. PIPE SUPPORTS FOR NUCLEAR CONSTRUCTION CATALOG NF09. • Certified Design Report Summaries • Load Capacity Data Sheets • Product Information Sheets • Ordering Instructions DRAFT COPY FOR REFERENCE ONLY Quality Standard Supports Meeting ASME Section III Subsection NF Requirements. 3 4 5 CATALOG 09.5NF - INDEX SHEET REV Part Number 1000 1001 1003 1047 1052 1200 2015 2250 2252 2420 2421 2440 2825-4" 2825-6" 2825-10" 2826-4" 2826-6" 2826-10" 2830-4" 2830-6" 2830-10" 2831-4" 2831-6" 2831 10" 2831-10" 2860-4" 2860-6" 2860-10" 2870-4" 2870-6" 2870-10" 3100 3100 Type GB 3200 Rev. 0 0 0 0 2 0 0 0 0 1 0 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 Description Restraint End Connection Restraint End Attachment Snubber Bracket and Pin Welded Beam Attachment Welding Lug Washer Plate Rigid Rod Strut Adjustable Rigid Strut Field Adjustable Rigid Strut Short Strut Assembly with MSA by PSC (Size 0.35 to 15) Short Strut Assembly with MSA by PSC (Size 50 and 120) Strut Assembly with PSC MSA Short STC Hydraulic Snubber Assembly (2 to 60 kips) Short STC Hydraulic Snubber Assembly (2 to 60 kips) Short STC Hydraulic Snubber Assembly (2 to 60 kips) Short STC Hydraulic Snubber Assembly (100 to 250 kips) Short STC Hydraulic Snubber Assembly (100 to 250 kips) Short STC Hydraulic Snubber Assembly (100 to 250 kips) Standard STC Hydraulic Snubber Assembly (2 to 60 kips) Standard STC Hydraulic Snubber Assembly (2 to 60 kips) Standard STC Hydraulic Snubber Assembly (2 to 60 kips) Standard STC Snubber Assembly (100 to 250 kips) Standard STC Snubber Assembly (100 to 250 kips) Standard STC Snubber Assembly (100 to 250 kips) Short STC Mechanical Snubber Assembly Short STC Mechanical Snubber Assembly Short STC Mechanical Snubber Assembly Standard STC Mechanical Snubber Assembly Standard STC Mechanical Snubber Assembly Standard STC Mechanical Snubber Assembly Variable Support Hanger Variable Support Hanger Variable Support Hanger 0 1 2 End of Index Page REV BERGEN-POWER PIPE SUPPORTS, INC. TRANSMITTAL INDEX SHEET Sheet 1 of 4 DATE: ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) 3 4 5 CATALOG 09.5NF - INDEX SHEET 0 1 2 REV Part Number Rev. 3200 Type GB 3201 3400 0 0 1 3400 Type GB 3401 4000 SHT. 1 4000 SHT. 2 4000 SHT. 3 4000 SHT. 4 4000 SHT. 5 4000 SHT. 6 4000 SHT. 7 4000 SHT. 8 4000 SHT. 9 4000 SHT. 10 4004 4007 4100 SHT. 1 4100 SHT. 2 4100 SHT. 3 4100 SHT. 4 4100 SHT SHT. 5 4100 SHT. 6 4100 SHT. 7 4100 SHT. 8 4100 SHT. 9 5000 5006 5100 5110 5130 5131 6015 SHT. 1 6015 SHT. 2 6015 SHT. 3 6100 0 0 0 1 2 2 2 1 N/A N/A 0 0 2 2 1 2 2 2 1 NA NA 0 0 0 0 0 0 0 0 0 0 0 0 Description Variable Support Hanger Variable Support Hanger Variable Support Hanger Variable Support Hanger Variable Support Hanger Constant Support Constant Support Constant Support Constant Support Constant Support Constant Support Not Used Not Used Constant Support Constant Support TC-4 Connection TC-7 Connection Constant Support Constant Support Constant Support Constant Support Constant Support Not Used Not Used Constant Support Constant Support Machine Thread Rod All Thread Rod Forged Steel Turnbuckle Forged Steel Clevis Forged Steel Weldless Eye Nut-RH Forged Steel Weldless Eye Nut-LH Friction Type Anchor Friction Type Anchor Friction Type Anchor Two Bolt Pipe Clamp End of Index Page REV BERGEN-POWER PIPE SUPPORTS, INC. CATALOG INDEX SHEET Sheet 2 of 4 DATE: ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) 3 4 5 CATALOG 09.5NF - INDEX SHEET REV Part Number 6101 6140 6150 6152 6175-0.7 6175-1.5 6175-4 6175-7 6175-12 6175-25 6175-35 6175-60 6175-80 6175-130 6202-.35 6202-.65 6202-0.7 6202-1.5 6202-4 6202-6 6202-7 6202-12 6202-15 6202 25 6202-25 6202-35 6202-50 6202-60 6202-80 6202-120 6202-130 6202-200 6242 6243 6252-.35 6252-.65 6252-0.7 6252-1.5 6252-4 Rev. 0 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Description Heavy Two Bolt Pipe Clamp Pipe Saddle Three Bolt Pipe Clamp Heavy Three Bolt Pipe Clamp Yoke Type Restraint Pipe Clamp Yoke Type Restraint Pipe Clamp Yoke Type Restraint Pipe Clamp Yoke Type Restraint Pipe Clamp Yoke Type Restraint Pipe Clamp Yoke Type Restraint Pipe Clamp Yoke Type Restraint Pipe Clamp Yoke Type Restraint Pipe Clamp Yoke Type Restraint Pipe Clamp Yoke Type Restraint Pipe Clamp Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Clamp for Strut Assemblies Pipe Strap Pipe Strap Off-Axis Pipe Clamp for Strut Assemblies Off-Axis Pipe Clamp for Strut Assemblies Off-Axis Pipe Clamp for Strut Assemblies Off-Axis Pipe Clamp for Strut Assemblies Off-Axis Pipe Clamp for Strut Assemblies 0 1 2 End of Index Page REV BERGEN-POWER PIPE SUPPORTS, INC. Sheet 3 of 4 CATALOG INDEX SHEET DATE: ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) 3 4 5 CATALOG 09.4NF - INDEX SHEET 0 1 2 REV Part Number 6252-6 6252-7 6252-12 6252-15 6252-25 6252-35 6252-50 6252-60 6280-0.7 6280-1.5 6280-4 6280-7 6280-12 6280-25 6280-35 6280-60 6300-0.73 6300-1.35 6300-3.23 6363 6439 6440 6441 6500 SHT SHT. 1 6500 SHT. 2 6502 SHT. 1 6502 SHT. 2 6504 SHT. 1 6504 SHT. 2 6525-0.7 6525-1.5 6526-0.7 6526-1.5 8460 8520 8560 8820 8821 8822 8823 8827 8828 8840 8860 Rev. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 1 1 1 0 0 0 0 0 0 0 0 0 Description Off-Axis Pipe Clamp for Strut Assemblies Off-Axis Pipe Clamp for Strut Assemblies Off-Axis Pipe Clamp for Strut Assemblies Off-Axis Pipe Clamp for Strut Assemblies Off-Axis Pipe Clamp for Strut Assemblies Off-Axis Pipe Clamp for Strut Assemblies Off-Axis Pipe Clamp for Strut Assemblies Off Axis Pipe Clamp for Strut Assemblies Restraint Riser Clamp Restraint Riser Clamp Restraint Riser Clamp Restraint Riser Clamp Restraint Riser Clamp Restraint Riser Clamp Restraint Riser Clamp Restraint Riser Clamp Riser Clamp Riser Clamp Riser Clamp Straight Pin & Cotter Pins Bolted Pipe Strap Pipe Strap Pipe Strap Long Tangent U U-Bolt Bolt Long Tangent U-Bolt Long Tangent U-Bolt Long Tangent U-Bolt Variable Tangent U-Bolt Variable Tangent U-Bolt U-Bolt Restraint Clamp U-Bolt Restraint Clamp U-Bolt Restraint Clamp U-Bolt Restraint Clamp U-Bolt Slide Guide Clamp Slide Clamp Slide Plate with Graphite Slide (Welded) Pre-Insulated Slide w/ No Strap Pre-Insulated Slide w/ Strap Pre-Insulated Slide w/ U-Bolt Pre-Insulated U-Bolt Guide Assy. Pre-Insulated Strap Guide Assy. Plate with Graphite Slide (Bolted) Graphite Guide Base (Welded) End of Index Page REV BERGEN-POWER PIPE SUPPORTS, INC. Sheet 4 of 4 CATALOG INDEX SHEET DATE: ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) tit r, CERTIFIED DESIGN REPORT SUMI'JIARY for N NUCLEAR POWER PLANT STANDARD SUPPORTS - . RESTRA'A'T END ATTACHMENT PART NUMBER |OOO SIZES 7 THROUGH SIZES .7 THROUGH 4 2OO <-__-_____> FORCE J ._ ._ --1 1g"J FORCE FORCE Temperature: no"t Design Spec. No. D91000 Design Repoft No. DR-1000 Kip Size I certify this CDRS complies with rcquirements of the applicaHe ,0r' the test condition (Hydro)the maximum temperature is 1000F, For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Condition Level A Operating Conditions Level B Level C Test Condition {see Note) Level D 1,315 931 2,819 1,995 700 700 931 1,050 1.5 1,500 1,500 1,995 2,250 4 4,000 4,000 5,320 6.000 7,516 5,320 7 7,000 7.000 9,310 10:500 13,153 9,310 0.7 12 12,000 12,000 15,960 18,000 22,il8 15,960 25 25,000 25,000 33,250 37,500 46,975 33,250 46,550 35 35,000 35,000 46,550 52,500 65,765 60 60,000 60,000 79,800 90,000 112,740 79,800 80 90,000 80,000 106,400 120,000 150,320 106,400 172,900 195,000 244,270 172,900 375,800 300,000 266,000 //bsl for Classes 1.2,3 & MC -oads (lbs) 266,000 130 130,000 130,000 200 200,000 200,000 CONTROLREFNO. be ode 3500F MATERIALS 1018 CW (CC N-71) Gr Plate: 3A-36, A108 Bolts: N/A Nuts: N/A Pin: SA 564 TYP 630 1()(l(} The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Bergen Power Pipe Supporfs, lnc. Studs: N/A Product Engineering DePaftment ilemptCotter pins, Washers, Retainers (NF-21 21) REVISIONS 4,{'>/.d'fr SEAL | /a/r7/a? lslGNED /o\ Oriqinal lssue 10/27109 /r\ /\ BERGEru POWER PIPE SUPPORIS, INC, /^ /^ /J SHEET 1 OF r REV. A PART NO. l(l(}(l CDRS CATALOG INFORMATION SHEET RESTRA''VI END ATTACHMENT . PART NUMBER |OOO SIZE 7 THROUGH 2OO SIZE .7 THROUGH 4 I @ __J T l. KIP SIZE E tt L 0.7 17t8 1t2 1118 N 9/1 6 1.5 2114 5/8 1112 3t4 4 21t4 27t8 5/8 11t2 3t4 7 12 25 27lB 3718 1 7t8 7t8 3112 3/8 5 3112 1112 11t2 21t8 23t8 R T 3/8 7t8 1t2 1112 1.0 1 1t8 1t2 13t4 2.5 1118 1t2 1314 2.5 3t4 1 118 314 3.0 3t4 11t8 15t8 314 31t4 31t4 1 4114 3.0 17 t8 1114 5 3.0 23t8 25t8 1112 6 6.6 314 7.2 13t4 8718 23t4 111t2 8.0 11t2 11t2 1 4114 1 5 5/8 111116 71t4 80 6114 9114 3 5/8 130 8112 2 11 5/8 4 518 21t2 3 3/8 5114 3 4118 60 200 10 3t4 112 113118 2 111 5/16 5 314 15 3 1314 7 *---J K* P 11t4 11t2 13t4 35 W *l 3.0 nla *xloE lb/in. NOTES: 1.) All dimensions are in inches' 2.) Dimbnsions are provided for user application only' plate' 3,) Spring rate (K) is for loads applied perpendicular to the base 2250,2252,2525,2530,2420,2421&2440' parts 2015, 4.)This assembly is to be use with BPPS ORDERING INSTRUCTIONS: Designation. Specify: part Number, CDRS Revision Number, and Kip Size DGMPLE: 1000-R/0-60 lssue 10/27109 BERGEN POWER PIPE SUPPORTS' INC, PART NO. lO(lO CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS RESIRII'fVT END ATTACHMENT . PART NUMBER 1OO1 SIZES15 THROUGH 120 SIZES .65 THROUGH 6 1 80" .+ <----)> FORCE FORCE J <___-__--__> H- -l FORCE FORCE 1oo--J Temperature: Nott' Design Report No. DR-1000 Size 0.65 the test condition (Hydro)the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature Fo1. Desion Soec. No. DS-1000 Kip 3500F shown for the Operating Condition' Design Gondition 650 Level A Operating Conditions Level C Level B 650 865 975 1,995 2,250 Test Condition Level D {see Note} 1,221 865 2,819 1,995 1.s 1,500 1,500 6 6,000 6,000 7,980 9,000 11,274 7,980 15 15,000 15,000 19,950 22,500 2E,185 19,950 50 50,000 50,000 66,500 75,000 93,950 66,500 120 120,000 120,000 159,600 180,000 225,480 159,600 Rated Loads (lhs) for Classes 1,2,3 &MC I certily this CDRS NO. comdies wilh he rcquirements of the applicable code ffir1o18cw(ccN-71 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Bergen Power PiPe SuPPods' lnc. Product Engineering DePartment ffiRetainers(NF-2121 REVISIONS BERGEN POWERPIPE SUPPORTS, INC, CDRS CATALOG INFORMATION SHEET RESIRII'TIJT END ATTACHMENT - PART NUMBER 1AO1 SIZE 15 THROUGH 120 SIZE.65 THROUGH 6 R-r \- I I L-*--l t.' KIP SIZE E 0.65 1 3/8 0.42 1.5 1314 0.52 L 1 11t2 N 3/8 1118 1t2 1112 3t4 11t2 5/8 2114 4114 0.77 2114 1118 1.01 5 21t8 8112 2.07 1114 7t8 1t2 3718 120 W 3t8 2114 1.70 T 1t2 6 5 5/8 R 3t4 15 50 P 3 7 114 115t8 4 5t8 1 1 3/8 1 11t2 2318 1112 6 21t2 3 3/8 1314 8718 NOTES: 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only' replacement rear brackets for 3.) For use with pacific scientific company manufactured struts and as BPPS Parls 2420,2421, and 2444' ORDERING INSTRUCTIONS: specify: Part Number, CDRS Revision Number, and Kip size Designation' DGMPLE: 1001-R/0-50 lssue 10/27109 BERGEN POWER PIPE SUPPORTS, INC. CDRS CATALOG INFORMATION SHEET SfVUBBER BRACKET and PIN - PART NUHBER 1003 r'l ,,,,,*nllhlllil,u" KIP SIZE 1 3/4 !{iin*. .'i11 2 .r4$P3 Ir' illtu' 't{ "||ll*$ ..af {ullilfl" 'll}lu" .url *{lll#ll,} 718 3/14"'- ulInk#il $dl, Iti,dfilt nxr$lF0 t" q"nn,p 1 1 5/16 L 1112 21t8 2 9t16 "r5'1/4 I 3/8 3718 1ffi 31t4 37t8 1 7t8 411t16 4 9/16 6718 2 3t4 61t4 P R T w 112 u4 5/10 11t2 9/16 I 11t4 9/16 11t16 1 1 1 17t8 2114 13/3 43t8 3 1 9/16 5 11/16 2 1.)Alldimensions are in inches. ire provided for user application only. 3.) This assembly is to be use wiilt B'P Parts 2825 and 2830. ORDERING INSIRUCTIOI{S: Specfy: Part Number, CDRS Revision Number, and Kip Size Designation. BERGEN',POWERHPE SUPPORT$ r tc. 3 3ffi 9/16 2.) Dimensions 1003'R/0-60 7t8 1 7t16 3/16 -$ffiffi $fiMPLE: 5/8 1ffi 2 2 1/10 ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) tiE, CERTIFIED DESIGN REPORT SUMMARY for d* dY NUCLEAR POWER PLANT STANDARD SUPPORTS WELDED BEAM ATTACHMENT TYPE . PART NUMBER 1047 TYPE 2 1 __i ri_ DIRECTION OF LOADING Temperature: N*t' Design Spec. No. D91047 Design Report No. DR-1047 Fol, the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Size Design Gondition 3/8 730 0perating Conditions Test Condition (see Note) Level A Level B Level C 730 971 1,095 1,153 971 2,025 2,133 1,796 Level D 1t2 1,350 1,350 1,796 5'8 2,160 2,160 2,873 3,240 3,413 2,873 3,230 4,296 4,845 5,103 4,296 3t4 3,230 5,900 1 3500F - 5,900 7,847 8,850 9,322 7,847 9,500 12,635 14,250 15,010 12,635 11t4 11t2 13,800 13,800 18,354 20,700 21,804 19,354 1314 18,600 18,600 24,738 27,900 29,388 24,738 9,500 2 24,600 24,600 32,718 36,900 38,868 32,718 21ll4 32,300 32,300 42,959 48,450 51,034 42,959 21n 39,800 39,800 52,934 59,700 62,884 52,934 Rated Loads ilbd for Classes 1,2,3 & MC CONTROL REF NO. lcertify this CDRS complies with he rcquircments of the aPPlicabh code MATERIALS The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Plate: 3A-36 Bolts: N/A Nuts: N/A Pin: SA-193 Gr 87 Bergen Power PlPe SuPPorts,lnc, Studs: N/A E-xemtt-otter pins, Was hers, 1047 Reta i n ers (N F-2 Product Engineering DePartment 1?]) REV|StONS 4-4;,.-/.M*G, /d, Oriqinal lssue 1 0/27109 /1' /) lpfr*f lslcNED BERGEN POWER PIPE SUPPORTS, INC, s'Ear /J /t /i SHEET 1 0F I REv. a PARTNO. 1047 CDRS CATALOG INFORMATION SHEET WELDED BEAM ATTACHMENT . PART NUfrIIBER 1047 TYPE 2 -J-J-- t_ r:= rt-Yt J+-+L P f-c -*1 --l w I --*l oL T 1t2 1t4 2 27t8 27t8 5/8 114 2 3t4 114 2 7t8 3/8 2112 11t8 1t2 3 1 3/8 5/8 4 5 E1 E G H 3'8 2 1718 1114 2718 1 1t4 2 112 2 5/8 314 1 13t4 13t4 1114 2 1314 3 2314 2 3 1/8 4112 2112 5 1112 w P ROD SIZE 11//4 3 27lB 11//2 4 4 3 6112 1518 3t4 7 314 314 1314 5 5 33t4 2 5 5114 3314 8114 21|4 6 6114 9112 2112 6 6114 41t4 41t2 17t8 21t4 21t2 I314 2314 E 314 6 3t4 6 314 6 NOTES: L)All dimensions are in inches' 2) Dimensions are provided for user application only' ORDERING INSTRUCTIONS: Specify: part Number, CDRS Revision Number, and Rod Size and Type EXAMPLE: 1047-R/0-3/4"-Type 1 (or) 2 inallssue 10127109 PART AENOEN POWER PIPE SUPPORTS' 'NC' NO. 1047 LOAD CAPACITY DATA SHEET for NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS WELDING LUG o DIRECTION OF LOADING TEMPERATURE: Load ratinq DESIGNED BY: 350 oF LOAD RATTNG (LBS) for Class 1,2,3 & MC srzE a EIIJ> 3/8 1/2 UPSET EMERGENCY 610 610 1 130 1 130 810 500 915 695 1 1 1810 1810 2400 2715 2710 4065 1 1t4 1 1t2 4960 8000 11630 1 5700 4960 8000 11630 1 5700 3600 6600 1 0600 1 5500 20900 20700 27200 20700 27200 33500 580 41 2 21/4 2 112 >I url EI ol z1 ==J <l al <l ul UJ LEVEL C NORMAL 2710 ol <l FD FI o ol t2 <l t ol JI o (, LEVEL B 314 13t4 url t2 I tr ltl OPERATING CONDMONS LEVEL A 5/8 1 JI DESIGN CONDITION 33500 580 50580 60480 2 314 41 3 50580 3114 60480 31t2 71280 71280 3 314 82890 95400 82890 95400 4 27600 36200 44600 55400 67400 80600 95000 1 1 0500 127200 7440 12000 17445 23550 31 050 40800 50250 62370 75870 90720 1 06920 124335 1 431 00 LEVEL D FAULTED 1220 2260 3620 5420 9920 1 6000 23260 31 400 41400 54400 67000 831 60 101160 1 20960 142560 1 65780 1 90800 TEST CONDITION 810 500 1 2400 3600 6600 1 0600 1 5500 20900 27600 36200 44600 55400 67400 80600 95000 1 1 0500 127204 >l z rJ,t I ul clI C) ol ()I g urI tr FI <t o al o-I I 4fl 4 N NOI E: I cenify that this LUUU comphes with the requirements of the applicable code. Materials: Stress calculations or test data for this Droduct werc perlormed ln accordance with: ASME BPVC CENTII"IN III CIINCEI1TI..IN NFNNMDT1NFNT Plate: SA-36 .< EIIJ> fiueeOnTs 2007 Edltlon and are on file at: BEBGEN.POWEB PIPE SUPPORTS, INL. J FilF o Product Engineering Department Cotter Pins, Washers, Retainers Exempt ( NF-2121) nlS -EI sONTROLREF. BERGEN-aIwER ptpE suppo+Ts, tvc. LoAD cAPActw DATA sHEET NO. 1052 Sheet j!_of 1 REV A PART NO. 1 052 BY CUSTOAAER ROD SIZE 3/8 112 9/1 6 518 3/4 1 3t4 11/16 13/16 15/16 2114 1 1 1 114 3 112 31t4 1 3/4 2 3 1t4 21/4 2 112 2 314 4 3 3 1t4 3112 3 3t4 4 4 114 R H 1 112 1 1/2 1/2 NorES: E 1 114 1 1t2 1314 2 2 3/8 2 5/8 1 114 1 1t4 1 1/4 1114 2 1t2 2 112 2 112 2 1t2 1/4 1 1t2 1/2 3 2 5/8 3/4 4 2 1/2 2 1/2 3 3 4 1 4 6 3 3/8 3 5/8 3 7/8 6 6 41t8 4 3t8 41/2 41t2 41t2 5 3/4 5 5 6 314 6 314 1 5 5 1/4 3/8 4 5 w 114 27t8 31t8 4112 T 1 114 1114 8 8 8 I 1 112 I 1 314 1 3/4 9 10 I 3',',1$3[1,"-l],1""11.lilii", "=", """,,"",,"" "",". ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation. EXAMPLE: IETS ru HJ 1052-Rl2- 314" BERGEN.POWER PIPE SUPPORTS INC. CATALOG INFORMATION SHEET PART DATE 1052 3/3/e3 tit CERTIFIED DESIGN REPORT SUMMARY for ], rul E NUCLEAR POWER PLANT STANDARD SUPPORTS WASHER P4I/.TE. PART NUMBER 12OO I O I DIRECTION OF LOADING Temperature: Nott' Design Spec. No. DS-1200 Design Repoil No. DR-1200 Size For, the test condition (Hydro)the maximum temperature is 1000F, For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Condition Level A Operating Conditions Level C Level B Test Condition (see Note) Level D 318 730 730 971 1,095 1,372 971 112 1,350 1,350 1,796 2,025 2,537 1,796 518 2,160 2.160 2,873 3,240 4,059 2,873 4,296 4,845 6,069 4,296 3,230 3,230 1 5,900 5,900 7,847 8,850 11,086 7,847 11ll4 9,500 9,500 12,635 14,250 17,851 12,635 3t4 1112 13,800 13,800 18,354 20,700 25,930 18,354 13|,4 18,600 18,600 24,738 27.900 34,949 24,738 2 24,600 24,600 32,718 36,900 46,223 32,718 2114 21//2 32,300 32,300 42,959 48,450 60,692 42,959 39,800 52.934 59.700 74,784 52,934 39,800 Rated Loads /lbs) for I certify 3500F ,2, CONTROLREFNO. lhis CDRS comdies with lhe requirements of lhe applicable code MATERIALS Plate: 5A-36 Bolts: N/A Nuts: N/A 12(l(l The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: N/A Bergen Power Pipe Supports,lnc, Studs: N/A Product Engineering DePailment Exempt N/A REVISIONS /'d"fr /o\ Orioinal lssue 1 0/27109 /i lp/n/a' lslGNED /^ BERGEN POWER PIPE SUPPORTS, NC, s(AL /s\ /l /J sHEEr 1 OF 1 REV. A PART NO. 12OO trl I, JI-.. CDRS CATALOG INFORMATION SHEET FJ WASHER PLATE - PART NUMBER 12OO -@I L tt H GAP HOLE 7t16 3 1t2 11t2 11t2 9/16 3 1t4 5/8 1112 11t16 3 3/8 13t16 4 3/8 1/1 6 4 1t2 ROD SIZE 3/8 314 NOTES: . 2 L&W T 1t4 1 21t2 11/,4 3 1 3/8 5 1t2 11t2 1 5/8 5 5/8 1314 31t2 31t2 1718 5 5/8 2 4 5 314 211,4 4 21t8 23t8 6 314 2112 4112 2518 6 3t4 1 __-] L)Alldimensions are in inches' 2.) Dimensions are provided for user application only. ORDERING INSTRUCTIONS: specify: Part Number, Revision Number, and Rod size Designation. EXAMPLE: 1200-R/0-3/8" REVISIONS /) /1' A Oriqinal lssue 10/27109 /t\ /i /i BERGEN POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV. A PART NO. 12OO titJ, CERTIFIED DESIGN REPORT SUMMARY for r* b NUCLEAR POWER PLANT STANDARD SUPPORTS RIGID RAD STRUI Y . PART NUMBER 2015 Ir ilil \) ,A Itl (z DnECnoil 0F DIRECTIOI{ OF LOADIiIG LOADING 10' .,e ...-------------- Temperature: Nott' Design Spec. No. D92010 Design Report No. DR-2015 3500F Fol. the test condition (Hydro)the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to fie temperature shown for the Operating Condition. Size Strut Lensth * Design Condition 0.7 2',-gu 700 Level A OperatinE Conditions Level B Level G 700 931 Test Condition Level D (see Note) 1,050 1,315 931 1,995 5,320 1.5 2'-9" 1,500 1,500 1,995 2,250 2,819 4 3'-0u 4,000 4,000 5,320 6.000 7,516 Rated Loads (lbs) for Classes 1,2,3 &MC * I certify this CDRS Maximum strut length (without adjustment)for rated loads shown with transverse acceleration 1G. CONTROLREFNO. 2015 mmflies with $e requirements of the applicable code < MATERIALS Plate: SA-36, A108 Gr 1018 CW (CC N-71) The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection Bolts: N/A Nuts: 5A-563 Gr A NF 2007 Edition and are on file at: Pin: 5A-564 TYP 630 Bergen Power Pipe Supporfg /nc. Rod: 5A-36 Product Engineering DePartment Exempt Cotter pins, Washers, Retainers, (NF-2121) REVtSt0NS E--bK'4'.e SEAL ln/zz/ai lslGNED /d, Oriqinal lssue 1 0/27109 /i BERGEA' POWER PIPE SUPPORTS, INC, ) /i l/ It i SHEET 1 OF 1 REV. A PART NO. 2015 lit r, CDRS CATALOG INFORMATION SHEET d b RIGID ROD STRUT . PART NUMBER 2015 Strut Length (P-P) irlr rrlt I L_V_ +-lrlrt --a-- -e -l-: _!- --.1- t l Swing Rad. KIP srzE 0.7 1.5 A B 3t4 1t2 314 4 1 . . D L E a P.P P MIN MAX FT.LBS 7t16 1718 1 118 3/8 10314 33 15 5/8 1t2 21t4 1t2 10 3t4 33 15 5/8 1t2 21t4 11t2 11t2 112 131t4 36 35 R s T W 1 1 1t2 1t2 11t2 13t4 1t2 11t2 13t4 13t4 11t8 11t4 1t2 X +l-314 23t4 23t4 3 5/8 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only, 3.) P-P dimensions given allow for a +l'1-112'adjustment. 4.) Set adjustment at the desired P-p and tighten the nuts to the nominal torque value (Q) as specified in the table above 5.)This strut is compatible with B-P Parts 6175,6202,6252,6280, 6525 and 6526. ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, Kip Size Designation, and P-P Length, EMMPLE: 2015-R/0-4k P-P = 24" REVISIONS i0\ Oriqinal lssue 10/27109 /z\ A /+\ /^ /5' BERGEN PAWER PIPE SUPPORTS, INC, SHEET 1 OF 1 REV. A PARTNO. 2015 CERTIFIED DESIGN REPORT SUMMARY tiJ J, for ,d NUCLEAR POWER PLANT STANDARD SUPPORTS - ADJUSTABLE RIGID STRUT (t . PART NUMBER 2250 2" Adjustment) DIREGTION OF LOADING DIRECTION OF LOADING .+ ...H> Temperature: Design Spec. No. DS-2100 Design Report No. DR-2250 3500F For the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Size Strut Length 0.7 * Design Condition 700 9'-4n Test Condition Operating Conditions (see Note) Level A Level B Level C Level D 700 931 1,050 1,315 931 2,819 1,995 5,320 1.5 9'-4n 1,500 1,500 1,995 2,250 4 10'-0' 4,000 4,000 5,320 6,000 7,516 10,500 13,153 9,310 15,960 7 10'-0" 7,000 7,000 9,310 12 10'-0" 12,000 12,000 15,960 18,000 22,548 25 10'-0n 25,000 25,000 33,250 37,500 46,975 33,250 46,550 35 10'-0' 46,550 52,500 65,765 10'-0' 35,000 60,000 35,000 60 60,000 79,800 90,000 112,740 79,800 80 10'-0n 90,000 80,000 106,400 120,000 150,320 106,400 130 10'-0* 130,000 130,000 172,900 195,000 244,270 172,904 200 10'-0' 200,000 200,000 266,000 300,000 375,800 266,000 Rated Loads (lbs) for Classes 1,2,3 & ML * I Maximum strut length with adjustment, for rated loads shown, 2250 CONTROL REF NO. certify this CDRS complies with the MATERIALS requirements of the applicable code Plate: SA-36, SA515 Gr 70 Rod: 5A-36, 4108 Gr 1018 (CC N-71) Nuts: 54-563 Gr A Pin: S4-564 TYP 630 Pipe: 54-106 Gr B, SA-53 Gr B Exempt Cotter pins, Washers, Retainers (NF-2121) The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Bergen Power Pipe SuPPods, lnc. Product En gineerin g DePartment REVISIONS b*fr,&ffi pa/27/af SEAL ISIGNED /o\ Oriqinal lssue 10/27109 /r' /z\ BERGE J POWER PIPE SUPPORTS, lNC. /i 4\ /s\ SHEET 1oF 1 | nev. /o\ I PART No. 2250 CDRS CATALOG INFORMATION SHEET ADJUSTABLE RIGID STRUT - PART NUMBER 2250 P-P (± 2" Adjustment) By Customer (Typ.) P A Q Torque (Typ.) D Size 0.7 through 12 R Swing Rad. Pipe (Nominal Dia.) A C Size 25 through 200 S E T Part 1000 B 10° U KIP A SIZE 0.7 1 1/8 1.5 1 1/2 4 1 1/2 *7 3 1/2 * 12 3 1/2 25 5 35 5 3/4 60 7 1/4 80 9 1/4 130 11 5/8 200 15 B C 1 1/2 1 3/4 1 3/4 3 1/4 3 1/4 4 1/4 5 6 7 3/4 8 7/8 11 1/2 9/16 3/4 3/4 1 1/2 1 1/2 2 1/8 2 3/8 3 3 5/8 4 5/8 5 1/4 D E 1/2 1 7/8 1/2 2 1/4 1/2 2 1/4 3/4 2 7/8 3/4 2 7/8 1 3 7/8 1 1/4 4 1/4 1 1/2 5 5/8 1 3/4 6 1/4 1 3/4 8 1/2 2 3/4 10 3/4 MIN 20 20 26 26 26 28 32 34 38 44 56 P-P MAX 112 112 120 120 120 120 120 120 120 120 120 PIPE Q R S T U 1 1/2 S/40 1 1/2 S/40 S/80 2 2 1/2 S/80 2 1/2 S/80 S/80 3 3 1/2 S/80 S/80 5 S/80 6 S/80 8 8 S/160 15 25 50 100 100 100 100 100 100 100 100 1 1 1/8 1 1/4 2 2 2 5/8 2 5/8 3 5/8 4 1/8 6 7 1/8 1 1/2 1 3/8 1 9/16 1 3/16 1 3/16 3 3 1/2 3 1/2 4 5 1/4 6 1/4 1/2 5/8 5/8 7/8 7/8 1 3/8 1 1/2 1 11/16 1 13/16 2 1/16 2 5/16 7/16 1/2 1/2 5/8 5/8 1 1 1/4 1 1/4 1 1/2 1 1/2 2 NOTES: 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only. 3.) P-P dimensions given allow for a + 2 " adjustment. 4.) Set strut at desired P-P and tighted nut to the nominal torque value (Q) for locking. 5.) This strut is compatible with B-P Parts 6175, 6202, 6252, 6280, 6525, and 6526. * 6.) The 7/12 kip strut use the welded type end attachment. ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, Kip Size Designation, and P-P Length. EXAMPLE: 2250-R/0-4k P-P = 30" REVISIONS 0 1 2 Original Issue 10/27/09 .7k "C", 7k "B", Added Note #6 8/3/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202 Pipe Size 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 5 6 8 10 Pipe Size 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 5 6 8 10 12 6202 Clamp 3.50E+05 3.68E+05 3.18E+05 3.33E+05 2.92E+05 2.33E+05 2.50E+05 1.84E+05 1.63E+05 1.35E+05 1.21E+05 1.25E+05 Max 114 1.42E+04 1.42E+04 1.41E+04 1.42E+04 1.41E+04 1.39E+04 1.40E+04 1.37E+04 1.36E+04 1.33E+04 1.32E+04 1.32E+04 Size 0.7 (700 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 1.43E+04 1.45E+04 1.47E+04 1.49E+04 1.44E+04 1.46E+04 1.48E+04 1.50E+04 1.43E+04 1.45E+04 1.47E+04 1.49E+04 1.43E+04 1.45E+04 1.47E+04 1.49E+04 1.42E+04 1.44E+04 1.46E+04 1.48E+04 1.40E+04 1.42E+04 1.44E+04 1.46E+04 1.41E+04 1.43E+04 1.45E+04 1.47E+04 1.38E+04 1.40E+04 1.42E+04 1.44E+04 1.37E+04 1.39E+04 1.40E+04 1.42E+04 1.35E+04 1.36E+04 1.38E+04 1.40E+04 1.33E+04 1.35E+04 1.36E+04 1.38E+04 1.33E+04 1.35E+04 1.37E+04 1.39E+04 Min 18 1.52E+04 1.52E+04 1.51E+04 1.51E+04 1.50E+04 1.48E+04 1.49E+04 1.46E+04 1.44E+04 1.42E+04 1.40E+04 1.41E+04 6202 Clamp 9.38E+05 7.14E+05 5.77E+05 6.00E+05 6.25E+05 5.56E+05 5.00E+05 4.17E+05 5.00E+05 3.66E+05 2.31E+05 1.65E+05 2.68E+05 Max 114 1.86E+04 1.85E+04 1.84E+04 1.84E+04 1.84E+04 1.84E+04 1.83E+04 1.82E+04 1.83E+04 1.81E+04 1.75E+04 1.70E+04 1.77E+04 Size 1.5 (1,500 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 1.88E+04 1.92E+04 1.95E+04 1.99E+04 1.87E+04 1.91E+04 1.94E+04 1.98E+04 1.86E+04 1.89E+04 1.93E+04 1.96E+04 1.86E+04 1.90E+04 1.93E+04 1.97E+04 1.87E+04 1.90E+04 1.93E+04 1.97E+04 1.86E+04 1.89E+04 1.93E+04 1.96E+04 1.85E+04 1.88E+04 1.92E+04 1.95E+04 1.84E+04 1.87E+04 1.90E+04 1.94E+04 1.85E+04 1.88E+04 1.92E+04 1.95E+04 1.83E+04 1.86E+04 1.89E+04 1.93E+04 1.77E+04 1.80E+04 1.84E+04 1.87E+04 1.72E+04 1.75E+04 1.78E+04 1.81E+04 1.79E+04 1.82E+04 1.86E+04 1.89E+04 Min 18 2.03E+04 2.02E+04 2.00E+04 2.01E+04 2.01E+04 2.00E+04 1.99E+04 1.98E+04 1.99E+04 1.96E+04 1.90E+04 1.84E+04 1.93E+04 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 6 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202 Pipe Size 2 1/2 3 4 5 6 8 10 12 14 16 18 20 24 30 36 6202 Clamp 1.14E+06 1.38E+06 1.25E+06 1.54E+06 1.05E+06 1.03E+06 7.55E+05 8.16E+05 6.78E+05 6.15E+05 5.71E+05 5.00E+05 6.06E+05 4.40E+05 3.74E+05 Max 122 5.52E+04 5.56E+04 5.54E+04 5.59E+04 5.49E+04 5.49E+04 5.38E+04 5.41E+04 5.34E+04 5.30E+04 5.26E+04 5.19E+04 5.29E+04 5.12E+04 5.02E+04 Size 4 (4,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 5.69E+04 5.86E+04 6.04E+04 6.23E+04 5.74E+04 5.91E+04 6.10E+04 6.29E+04 5.72E+04 5.89E+04 6.07E+04 6.26E+04 5.77E+04 5.94E+04 6.12E+04 6.32E+04 5.67E+04 5.84E+04 6.01E+04 6.20E+04 5.66E+04 5.83E+04 6.00E+04 6.19E+04 5.55E+04 5.71E+04 5.88E+04 6.06E+04 5.58E+04 5.74E+04 5.92E+04 6.10E+04 5.50E+04 5.66E+04 5.83E+04 6.01E+04 5.46E+04 5.61E+04 5.78E+04 5.95E+04 5.42E+04 5.58E+04 5.74E+04 5.91E+04 5.35E+04 5.50E+04 5.66E+04 5.82E+04 5.45E+04 5.61E+04 5.77E+04 5.94E+04 5.27E+04 5.42E+04 5.57E+04 5.73E+04 5.16E+04 5.30E+04 5.45E+04 5.60E+04 Min 24 6.39E+04 6.46E+04 6.42E+04 6.49E+04 6.36E+04 6.35E+04 6.21E+04 6.25E+04 6.16E+04 6.10E+04 6.05E+04 5.96E+04 6.09E+04 5.87E+04 5.73E+04 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 2 OF 6 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202 Pipe Size 3 4 5 6 8 10 12 14 16 18 20 24 30 32 36 Pipe Size 3 4 5 6 8 10 12 14 16 18 20 24 30 32 36 6202 Clamp 1.27E+06 1.30E+06 1.89E+06 1.49E+06 1.21E+06 1.25E+06 1.00E+06 8.43E+05 7.87E+05 6.73E+05 5.93E+05 4.86E+05 5.47E+05 3.80E+05 4.07E+05 Max 122 1.57E+05 1.58E+05 1.64E+05 1.60E+05 1.56E+05 1.57E+05 1.52E+05 1.48E+05 1.46E+05 1.42E+05 1.38E+05 1.31E+05 1.35E+05 1.22E+05 1.25E+05 Size 7 (7,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 1.67E+05 1.77E+05 1.88E+05 2.00E+05 1.67E+05 1.77E+05 1.88E+05 2.01E+05 1.74E+05 1.85E+05 1.97E+05 2.11E+05 1.70E+05 1.80E+05 1.92E+05 2.05E+05 1.66E+05 1.75E+05 1.86E+05 1.99E+05 1.67E+05 1.76E+05 1.87E+05 2.00E+05 1.61E+05 1.70E+05 1.80E+05 1.92E+05 1.56E+05 1.65E+05 1.75E+05 1.85E+05 1.54E+05 1.63E+05 1.72E+05 1.82E+05 1.49E+05 1.57E+05 1.66E+05 1.76E+05 1.45E+05 1.52E+05 1.61E+05 1.70E+05 1.38E+05 1.44E+05 1.52E+05 1.60E+05 1.42E+05 1.49E+05 1.57E+05 1.66E+05 1.28E+05 1.33E+05 1.39E+05 1.46E+05 1.30E+05 1.36E+05 1.43E+05 1.50E+05 Min 24 2.11E+05 2.12E+05 2.24E+05 2.17E+05 2.10E+05 2.11E+05 2.02E+05 1.95E+05 1.92E+05 1.84E+05 1.78E+05 1.67E+05 1.73E+05 1.52E+05 1.56E+05 6202 Clamp 2.18E+06 2.22E+06 3.24E+06 2.55E+06 2.07E+06 2.14E+06 1.71E+06 1.45E+06 1.35E+06 1.15E+06 1.02E+06 8.33E+05 9.38E+05 6.52E+05 6.98E+05 Max 122 2.70E+05 2.70E+05 2.81E+05 2.75E+05 2.68E+05 2.69E+05 2.61E+05 2.54E+05 2.51E+05 2.43E+05 2.36E+05 2.25E+05 2.32E+05 2.09E+05 2.14E+05 Size 12 (12,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 2.99E+05 3.32E+05 3.73E+05 4.26E+05 3.00E+05 3.33E+05 3.75E+05 4.28E+05 3.13E+05 3.50E+05 3.96E+05 4.55E+05 3.05E+05 3.40E+05 3.83E+05 4.39E+05 2.97E+05 3.29E+05 3.70E+05 4.22E+05 2.98E+05 3.31E+05 3.72E+05 4.25E+05 2.88E+05 3.19E+05 3.57E+05 4.05E+05 2.80E+05 3.08E+05 3.43E+05 3.88E+05 2.76E+05 3.04E+05 3.38E+05 3.80E+05 2.67E+05 2.93E+05 3.24E+05 3.63E+05 2.59E+05 2.83E+05 3.12E+05 3.48E+05 2.45E+05 2.67E+05 2.92E+05 3.24E+05 2.53E+05 2.76E+05 3.04E+05 3.39E+05 2.26E+05 2.45E+05 2.66E+05 2.92E+05 2.32E+05 2.51E+05 2.74E+05 3.01E+05 Min 24 4.81E+05 4.83E+05 5.18E+05 4.97E+05 4.75E+05 4.79E+05 4.54E+05 4.32E+05 4.23E+05 4.02E+05 3.84E+05 3.54E+05 3.72E+05 3.17E+05 3.27E+05 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 3 OF 6 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202 Pipe Size 4 5 6 8 10 12 14 16 18 20 24 30 36 Pipe Size 8 10 12 14 16 18 20 24 30 36 6202 Clamp 3.25E+06 3.62E+06 3.47E+06 2.98E+06 2.96E+05 2.78E+06 2.66E+06 2.38E+06 2.25E+06 2.07E+06 1.75E+06 1.27E+06 1.32E+06 Max 122 5.03E+05 5.11E+05 5.08E+05 4.96E+05 1.97E+05 4.90E+05 4.86E+05 4.76E+05 4.71E+05 4.62E+05 4.44E+05 4.05E+05 4.10E+05 Size 25 (25,000 lbf) ** Assembly Pin - Pin (inches) 40 100 80 60 5.83E+05 6.82E+05 8.21E+05 1.03E+06 5.94E+05 6.97E+05 8.43E+05 1.07E+06 5.90E+05 6.91E+05 8.35E+05 1.05E+06 5.74E+05 6.69E+05 8.03E+05 1.00E+06 2.09E+05 2.20E+05 2.33E+05 2.47E+05 5.66E+05 6.59E+05 7.87E+05 9.79E+05 5.61E+05 6.52E+05 7.78E+05 9.64E+05 5.47E+05 6.34E+05 7.52E+05 9.24E+05 5.40E+05 6.24E+05 7.39E+05 9.04E+05 5.29E+05 6.09E+05 7.17E+05 8.73E+05 5.05E+05 5.78E+05 6.75E+05 8.11E+05 4.56E+05 5.14E+05 5.89E+05 6.90E+05 4.62E+05 5.21E+05 5.99E+05 7.03E+05 Min 26 1.26E+06 1.31E+06 1.29E+06 1.21E+06 2.58E+05 1.18E+06 1.16E+06 1.10E+06 1.07E+06 1.03E+06 9.44E+05 7.84E+05 8.01E+05 6202 Clamp 4.27E+06 3.80E+06 3.18E+06 3.24E+06 2.78E+06 2.69E+06 2.27E+06 2.08E+06 1.88E+06 1.73E+06 Max 122 6.34E+05 6.23E+05 6.03E+05 6.06E+05 5.87E+05 5.83E+05 5.61E+05 5.49E+05 5.34E+05 5.21E+05 Size 35 (35,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 7.39E+05 8.70E+05 1.06E+06 1.35E+06 7.24E+05 8.49E+05 1.03E+06 1.30E+06 6.98E+05 8.13E+05 9.75E+05 1.22E+06 7.01E+05 8.17E+05 9.80E+05 1.22E+06 6.76E+05 7.84E+05 9.33E+05 1.15E+06 6.71E+05 7.77E+05 9.23E+05 1.14E+06 6.41E+05 7.38E+05 8.68E+05 1.05E+06 6.25E+05 7.17E+05 8.39E+05 1.01E+06 6.06E+05 6.91E+05 8.04E+05 9.62E+05 5.90E+05 6.70E+05 7.76E+05 9.22E+05 Min 30 1.56E+06 1.49E+06 1.39E+06 1.40E+06 1.31E+06 1.29E+06 1.18E+06 1.13E+06 1.07E+06 1.02E+06 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 4 OF 6 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202 Pipe Size 10 12 14 16 18 20 24 30 36 Pipe Size 10 12 14 16 18 20 24 30 36 6202 Clamp 5.04E+06 5.08E+06 4.69E+06 4.20E+06 4.41E+06 3.92E+06 3.39E+06 3.02E+06 2.48E+06 Max 122 9.39E+05 9.40E+05 9.26E+05 9.05E+05 9.15E+05 8.92E+05 8.61E+05 8.34E+05 7.87E+05 Size 60 (60,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 1.08E+06 1.24E+06 1.46E+06 1.78E+06 1.08E+06 1.24E+06 1.46E+06 1.78E+06 1.06E+06 1.22E+06 1.43E+06 1.73E+06 1.03E+06 1.18E+06 1.38E+06 1.66E+06 1.04E+06 1.20E+06 1.40E+06 1.69E+06 1.01E+06 1.16E+06 1.35E+06 1.62E+06 9.74E+05 1.11E+06 1.28E+06 1.52E+06 9.40E+05 1.06E+06 1.22E+06 1.44E+06 8.81E+05 9.88E+05 1.12E+06 1.30E+06 Min 32 1.95E+06 1.95E+06 1.89E+06 1.81E+06 1.85E+06 1.75E+06 1.64E+06 1.55E+06 1.39E+06 6202 Clamp 7.55E+06 6.67E+06 6.50E+06 5.80E+06 5.63E+06 4.76E+06 4.68E+06 3.79E+06 3.51E+06 Max 122 1.49E+06 1.45E+06 1.45E+06 1.41E+06 1.40E+06 1.34E+06 1.33E+06 1.25E+06 1.22E+06 Size 80 (80,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 1.75E+06 2.07E+06 2.54E+06 3.28E+06 1.70E+06 2.00E+06 2.43E+06 3.10E+06 1.69E+06 1.98E+06 2.41E+06 3.07E+06 1.63E+06 1.91E+06 2.31E+06 2.90E+06 1.62E+06 1.89E+06 2.28E+06 2.86E+06 1.54E+06 1.78E+06 2.12E+06 2.62E+06 1.53E+06 1.77E+06 2.11E+06 2.59E+06 1.42E+06 1.63E+06 1.90E+06 2.29E+06 1.38E+06 1.57E+06 1.83E+06 2.19E+06 Min 36 3.49E+06 3.29E+06 3.25E+06 3.06E+06 3.01E+06 2.75E+06 2.72E+06 2.39E+06 2.28E+06 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 5 OF 6 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202 Pipe Size 14 16 18 20 24 30 36 Pipe Size 16 18 20 24 30 36 6202 Clamp 8.90E+06 8.44E+06 7.78E+06 7.22E+06 6.91E+06 6.07E+06 5.10E+06 Max 122 1.95E+06 1.93E+06 1.89E+06 1.86E+06 1.84E+06 1.77E+06 1.68E+06 Size 130 (130,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 2.23E+06 2.57E+06 3.03E+06 2.20E+06 2.53E+06 2.97E+06 2.16E+06 2.47E+06 2.89E+06 2.11E+06 2.41E+06 2.80E+06 2.08E+06 2.37E+06 2.76E+06 2.00E+06 2.27E+06 2.61E+06 1.88E+06 2.11E+06 2.41E+06 Min 42 3.60E+06 3.52E+06 3.40E+06 3.29E+06 3.23E+06 3.03E+06 2.77E+06 6202 Clamp 1.39E+07 1.38E+07 1.40E+07 1.31E+07 1.50E+07 1.50E+07 Max 122 3.11E+06 3.10E+06 3.11E+06 3.06E+06 3.16E+06 3.16E+06 Size 200 (200,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 3.51E+06 3.99E+06 4.62E+06 3.51E+06 3.99E+06 4.61E+06 3.52E+06 4.00E+06 4.63E+06 3.46E+06 3.92E+06 4.53E+06 3.58E+06 4.08E+06 4.74E+06 3.58E+06 4.08E+06 4.74E+06 Min 52 4.93E+06 4.92E+06 4.95E+06 4.83E+06 5.07E+06 5.07E+06 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 6 OF 6 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175 Pipe Size 3 4 5 6 8 10 12 Pipe Size 3 4 5 6 8 10 12 6175 Clamp 1.17E+06 1.00E+06 7.78E+05 7.00E+05 5.00E+05 4.12E+05 3.89E+05 Max 114 1.46E+04 1.46E+04 1.45E+04 1.45E+04 1.44E+04 1.43E+04 1.43E+04 Size 0.7 (700 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 1.48E+04 1.50E+04 1.52E+04 1.54E+04 1.47E+04 1.49E+04 1.51E+04 1.54E+04 1.47E+04 1.49E+04 1.51E+04 1.53E+04 1.46E+04 1.48E+04 1.50E+04 1.53E+04 1.45E+04 1.47E+04 1.49E+04 1.51E+04 1.44E+04 1.46E+04 1.48E+04 1.50E+04 1.44E+04 1.46E+04 1.48E+04 1.50E+04 Min 18 1.56E+04 1.56E+04 1.55E+04 1.55E+04 1.54E+04 1.53E+04 1.52E+04 6175 Clamp 1.36E+06 1.15E+06 8.33E+05 7.50E+05 5.56E+05 4.41E+05 2.24E+05 Max 114 1.87E+04 1.87E+04 1.86E+04 1.85E+04 1.84E+04 1.82E+04 1.75E+04 Size 1.5 (1,500 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 1.90E+04 1.93E+04 1.97E+04 2.00E+04 1.89E+04 1.93E+04 1.96E+04 2.00E+04 1.88E+04 1.91E+04 1.95E+04 1.98E+04 1.87E+04 1.91E+04 1.94E+04 1.98E+04 1.86E+04 1.89E+04 1.93E+04 1.96E+04 1.84E+04 1.87E+04 1.91E+04 1.94E+04 1.77E+04 1.80E+04 1.83E+04 1.86E+04 Min 18 2.04E+04 2.04E+04 2.03E+04 2.02E+04 2.00E+04 1.98E+04 1.90E+04 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 6 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175 Pipe Size 3 4 5 6 8 10 12 14 16 6175 Clamp 2.11E+06 1.74E+06 1.29E+06 1.14E+06 9.09E+05 7.14E+05 7.02E+05 6.15E+05 4.82E+05 Max 122 5.64E+04 5.61E+04 5.55E+04 5.52E+04 5.45E+04 5.36E+04 5.35E+04 5.30E+04 5.17E+04 Size 4 (4,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 5.83E+04 6.00E+04 6.19E+04 6.39E+04 5.79E+04 5.97E+04 6.15E+04 6.35E+04 5.73E+04 5.90E+04 6.08E+04 6.27E+04 5.69E+04 5.86E+04 6.04E+04 6.23E+04 5.62E+04 5.79E+04 5.96E+04 6.15E+04 5.53E+04 5.69E+04 5.86E+04 6.03E+04 5.52E+04 5.68E+04 5.85E+04 6.03E+04 5.46E+04 5.61E+04 5.78E+04 5.95E+04 5.33E+04 5.48E+04 5.63E+04 5.80E+04 Min 24 6.56E+04 6.52E+04 6.43E+04 6.39E+04 6.30E+04 6.19E+04 6.18E+04 6.10E+04 5.94E+04 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 2 OF 6 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175 Pipe Size 3 4 6 8 10 12 14 16 18 20 24 Pipe Size 3 4 6 8 10 12 14 16 18 20 24 30 6175 Clamp 1.15E+06 1.43E+06 1.27E+06 1.15E+06 8.33E+05 7.78E+05 6.19E+05 4.83E+05 3.70E+05 2.92E+06 3.93E+05 Max 122 1.55E+05 1.59E+05 1.57E+05 1.55E+05 1.48E+05 1.46E+05 1.39E+05 1.31E+05 1.21E+05 1.69E+05 1.23E+05 Size 7 (7,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 1.65E+05 1.74E+05 1.85E+05 1.97E+05 1.69E+05 1.79E+05 1.91E+05 2.04E+05 1.67E+05 1.77E+05 1.88E+05 2.00E+05 1.65E+05 1.74E+05 1.85E+05 1.97E+05 1.56E+05 1.65E+05 1.74E+05 1.85E+05 1.54E+05 1.62E+05 1.72E+05 1.82E+05 1.47E+05 1.54E+05 1.62E+05 1.72E+05 1.37E+05 1.44E+05 1.51E+05 1.59E+05 1.26E+05 1.32E+05 1.38E+05 1.45E+05 1.80E+05 1.92E+05 2.05E+05 2.20E+05 1.29E+05 1.35E+05 1.41E+05 1.48E+05 Min 24 2.08E+05 2.15E+05 2.11E+05 2.08E+05 1.94E+05 1.91E+05 1.80E+05 1.66E+05 1.51E+05 2.33E+05 1.54E+05 6175 Clamp 1.97E+06 2.45E+06 2.18E+06 1.97E+06 1.43E+06 1.33E+06 1.06E+06 8.28E+05 6.35E+05 5.00E+06 6.74E+05 4.27E+05 Max 122 2.66E+05 2.73E+05 2.70E+05 2.66E+05 2.53E+05 2.50E+05 2.39E+05 2.24E+05 2.07E+05 2.90E+05 2.11E+05 1.79E+05 Size 12 (12,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 2.95E+05 3.27E+05 3.67E+05 4.17E+05 3.04E+05 3.38E+05 3.81E+05 4.36E+05 2.99E+05 3.32E+05 3.73E+05 4.26E+05 2.95E+05 3.27E+05 3.67E+05 4.17E+05 2.79E+05 3.08E+05 3.43E+05 3.87E+05 2.75E+05 3.03E+05 3.37E+05 3.79E+05 2.61E+05 2.86E+05 3.16E+05 3.54E+05 2.44E+05 2.66E+05 2.92E+05 3.23E+05 2.24E+05 2.42E+05 2.64E+05 2.89E+05 3.24E+05 3.63E+05 4.13E+05 4.79E+05 2.29E+05 2.48E+05 2.70E+05 2.97E+05 1.91E+05 2.04E+05 2.19E+05 2.36E+05 Min 24 4.70E+05 4.93E+05 4.81E+05 4.70E+05 4.31E+05 4.22E+05 3.90E+05 3.53E+05 3.13E+05 5.49E+05 3.22E+05 2.52E+05 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 3 OF 6 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175 Pipe Size 6 8 10 12 14 16 18 20 24 30 36 Pipe Size 12 14 16 18 20 24 30 36 6175 Clamp 3.09E+06 2.84E+06 2.10E+06 2.08E+06 1.54E+06 1.40E+06 1.00E+06 8.45E+05 7.02E+05 7.72E+05 6.30E+05 Max 122 4.99E+05 4.92E+05 4.64E+05 4.63E+05 4.30E+05 4.17E+05 3.74E+05 3.49E+05 3.22E+05 3.36E+05 3.06E+05 Size 25 (25,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 5.78E+05 6.75E+05 8.10E+05 1.01E+06 5.69E+05 6.62E+05 7.92E+05 9.86E+05 5.31E+05 6.12E+05 7.21E+05 8.79E+05 5.30E+05 6.10E+05 7.19E+05 8.76E+05 4.87E+05 5.54E+05 6.42E+05 7.64E+05 4.71E+05 5.33E+05 6.15E+05 7.26E+05 4.16E+05 4.64E+05 5.25E+05 6.03E+05 3.86E+05 4.27E+05 4.78E+05 5.42E+05 3.53E+05 3.87E+05 4.28E+05 4.79E+05 3.70E+05 4.07E+05 4.53E+05 5.11E+05 3.34E+05 3.64E+05 4.00E+05 4.45E+05 Min 26 1.23E+06 1.19E+06 1.04E+06 1.03E+06 8.80E+05 8.31E+05 6.74E+05 5.98E+05 5.23E+05 5.61E+05 4.82E+05 6175 Clamp 2.99E+06 2.50E+06 2.38E+06 2.33E+06 2.03E+06 2.11E+06 1.47E+06 1.47E+06 Max 122 5.96E+05 5.74E+05 5.67E+05 5.65E+05 5.45E+05 5.50E+05 4.94E+05 4.94E+05 Size 35 (35,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 6.88E+05 8.00E+05 9.56E+05 1.19E+06 6.58E+05 7.60E+05 9.00E+05 1.10E+06 6.50E+05 7.49E+05 8.84E+05 1.08E+06 6.46E+05 7.44E+05 8.77E+05 1.07E+06 6.21E+05 7.11E+05 8.31E+05 1.00E+06 6.28E+05 7.20E+05 8.43E+05 1.02E+06 5.56E+05 6.27E+05 7.19E+05 8.42E+05 5.56E+05 6.27E+05 7.19E+05 8.42E+05 Min 30 1.35E+06 1.24E+06 1.21E+06 1.20E+06 1.11E+06 1.14E+06 9.21E+05 9.21E+05 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 4 OF 6 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175 Pipe Size 12 14 16 18 20 24 30 36 Pipe Size 12 14 16 18 20 24 30 36 6175 Clamp 7.79E+06 6.59E+06 6.52E+06 5.22E+06 3.33E+06 3.06E+06 2.47E+06 1.97E+06 Max 122 1.01E+06 9.82E+05 9.80E+05 9.45E+05 8.57E+05 8.38E+05 7.86E+05 7.28E+05 Size 60 (60,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 1.16E+06 1.36E+06 1.63E+06 2.03E+06 1.13E+06 1.31E+06 1.57E+06 1.94E+06 1.13E+06 1.31E+06 1.56E+06 1.93E+06 1.08E+06 1.25E+06 1.47E+06 1.80E+06 9.69E+05 1.10E+06 1.27E+06 1.51E+06 9.45E+05 1.07E+06 1.23E+06 1.45E+06 8.80E+05 9.86E+05 1.12E+06 1.30E+06 8.07E+05 8.96E+05 1.01E+06 1.15E+06 Min 32 2.25E+06 2.14E+06 2.13E+06 1.97E+06 1.63E+06 1.56E+06 1.39E+06 1.22E+06 6175 Clamp 1.07E+07 1.14E+06 1.05E+07 9.52E+06 9.64E+06 7.69E+06 7.21E+06 6.61E+06 Max 122 1.58E+06 7.08E+05 1.58E+06 1.56E+06 1.56E+06 1.50E+06 1.48E+06 1.45E+06 Size 80 (80,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 40 1.88E+06 2.25E+06 2.82E+06 3.76E+06 7.61E+05 8.16E+05 8.80E+05 9.55E+05 1.87E+06 2.25E+06 2.81E+06 3.74E+06 1.84E+06 2.20E+06 2.73E+06 3.61E+06 1.84E+06 2.20E+06 2.74E+06 3.63E+06 1.76E+06 2.08E+06 2.56E+06 3.31E+06 1.73E+06 2.04E+06 2.50E+06 3.22E+06 1.69E+06 1.99E+06 2.42E+06 3.09E+06 Min 36 4.03E+06 9.72E+05 4.01E+06 3.86E+06 3.88E+06 3.52E+06 3.41E+06 3.27E+06 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 5 OF 6 REV. 1 PART NO. 2250 SPRING RATE INFORMATION SHEET ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175 Pipe Size 14 16 18 20 24 30 36 6175 Clamp 1.57E+07 1.59E+07 1.44E+07 1.40E+07 1.23E+07 1.13E+07 9.42E+06 Max 122 2.16E+06 2.16E+06 2.13E+06 2.12E+06 2.08E+06 2.05E+06 1.98E+06 Size 130 (130,000 lbf) ** Assembly Pin - Pin (inches) 100 80 60 2.50E+06 2.94E+06 3.55E+06 2.51E+06 2.94E+06 3.56E+06 2.47E+06 2.89E+06 3.48E+06 2.46E+06 2.87E+06 3.45E+06 2.40E+06 2.79E+06 3.34E+06 2.36E+06 2.74E+06 3.26E+06 2.26E+06 2.61E+06 3.08E+06 Min 42 4.37E+06 4.38E+06 4.27E+06 4.22E+06 4.05E+06 3.94E+06 3.68E+06 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Strut, End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 6 OF 6 REV. 1 PART NO. 2250 rfi J, CERTIFIED DESIGN REPORT SUMMARY for d ? NUCLEAR POWER PLANT STANDARD SUPPORTS ADJUSTABLE RIGID STRUT (t . PART NUMBER 2252 4. Adjustment) DIRECTION OF LOADING DIRECTIOI{ OF LOADING fu) .H t ..H T emperature: Design Spec. No. DS-2100 Design Report No. DR-2250 3sooF For the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Size Strut Lenqth * Design Condition 0.7 9',-2n 700 700 Test Condition (see Note) 1,050 1,315 931 2,819 7,516 5,320 9'-2n 1,500 1,500 1,995 2,250 4 9'-10u 4,000 4,000 5,320 6,000 1,995 7 9'-10" 7,000 7,000 9,310 10,500 13,153 9,310 12 9'-10'. 12,000 12,000 15,960 18,000 22,548 15,960 25 9'-10' 25,000 25,000 46,975 33,250 9'-10' 35,000 35,000 33,250 46,550 37,500 35 52,500 65,765 46,550 60 9'-10" g',-10' 60,000 60,000 79,800 90,000 112,740 79,800 80 80,000 80,000 106,400 120,000 150,320 106,400 130 9'-10' 130,000 130,000 172,900 195,000 244,270 200 9'-10n 200,000 375,800 266,000 300,000 Rated Loads (lbs) for Classes 1,2,3 &MC 200,000 172,900 266,000 Maximum strut length with adjustment, for rated loads shown. 2252 CONTROL REF NO. this CDRS complies with the requirements of Level D 931 r.5 * lcertit Level A Operating Conditions Level B Level C he applicable code MATERIALS The Design Report & Design Specification are in Plate: SA-36, SA515 Gr 70 Rod: SA-36, A108 Gr 1018 (CC N-71) Nuts: 3A-563 Gr A accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 5A-564 TYP 630 Pipe: SA-106 Gr B, SA-53 Gr B Exempt: Cotter pins, Washers, Retainers Bergen Power Pipe Supporfs, lnc. Product Engineering Department {Ifi?l?]l REVISIONS {, /N ,e' -r- SEAL r(r&.* l747gz/al ISIGNED Oriqinal lssue 1 0/27109 A /z\ BERGEN POWERPIPE SUPPORTS, INC. /J A /J SHEET 1oF I I nev. /o\ I PART No. 2252 CDRS CATALOG INFORMATION SHEET ADJUSTABLE RIGID STRUT - PART NUMBER 2252 P-P (± 4" Adjustment) Cut Length (note 3) P A Q Torque (Typ.) D Size 0.7 through 12 W Pipe (Nominal Dia.) R Swing Rad. E70XX Note 6 (Typ.) A C Size 25 and 35 S Part 1000 Note 7 Cut Length (note 3) E T B 10° U N By Customer (Typ.) KIP SIZE 0.7 1.5 4 *7 * 12 25 35 60 80 130 200 M W Size 60, 80, 130, 200 P-P PIPE Q M N R S MIN 1 1/8 1 1/2 9/16 1/2 1 7/8 3/8 22 1 1/2 S/40 15 1 1 1/2 1 1/2 1 3/4 3/4 1/2 2 1/4 1/2 22 1 1/2 S/40 25 - 1 1/8 1 3/8 S/80 2 1 1/2 1 3/4 3/4 1/2 2 1/4 1/2 28 50 - 1 1/4 1 9/16 3 1/2 3 1/4 1 1/2 3/4 2 7/8 3/4 28 2 1/2 S/80 100 2 1 3/16 3 1/2 3 1/4 1 1/2 3/4 2 7/8 3/4 28 2 1/2 S/80 100 2 1 3/16 S/80 3 5 4 1/4 2 1/8 1 3 7/8 1 30 100 - 2 5/8 3 5 3/4 5 2 3/8 1 1/4 4 1/4 1 1/4 34 3 1/2 S/80 100 - 2 5/8 3 1/2 S/80 5 7 1/4 6 3 1 1/2 5 5/8 1 1/2 36 100 2 3/4 5/8 3 5/8 3 1/2 S/80 6 9 1/4 7 3/4 3 5/8 1 3/4 6 1/4 1 3/4 40 100 3 1/2 5/8 4 1/8 4 S/80 8 11 5/8 8 7/8 4 5/8 1 3/4 8 1/2 2 1/2 46 100 4 1/8 3/4 6 5 1/4 8 S/160 100 15 11 1/2 5 1/4 2 3/4 10 3/4 3 58 5 5/8 1 1/8 7 1/8 6 1/4 NOTES: 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only. 3.) Cut length = Desired "P-P" - X. All struts are supplied at maximum. 4.) Set strut at desired P-P and tighted nut to the nominal torque value (Q) for locking. 5.) This strut is compatible with B-P Parts 6175, 6202, 6252, 6280, 6525, and 6526. 6.) Weld "W" performed by others after cutting the pipe to suit the desired P-P. 7.) Drill 3/8" dia. sight hole at "M" on cut end only, sizes 60 thru 200. 8.) Configuration is the same on both ends for sizes 25 thru 200 . * 9.) The 7/12 kip strut use the welded type end attachment. A B C D E P E70XX Note 6 (Typ.) T U 1/2 5/8 5/8 7/8 7/8 1 3/8 1 1/2 1 11/16 1 13/16 2 1/16 2 5/16 7/16 1/2 1/2 5/8 5/8 1 1 1/4 1 1/4 1 1/2 1 1/2 2 W X 1/8 10 7/8 1/8 10 7/8 3/16 12 1/4 1/4 15 1/4 15 1/4 18 5/16 20 3/8 14 9/16 3/8 15 11/16 1/2 19 11/16 7/8 24 1/4 ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, Kip Size Designation, and P-P Length. EXAMPLE: 2252-R/0-4k P-P = 30" REVISIONS 0 1 2 Original Issue 10/27/09 .7k "C", Added Note #9 8/3/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV. 1 PART NO. 2252 til {Ctl:77 LOAD CAPACITY DATA SHEET for PIAI{T COTAPONENT STAHDAND SHORT STRUT ASSEMBLY T{ITIT MSA BY PSC NUCTEAR POWEN SUPPC'TTS DIRECTION c)F TOADING LOAD RATING DESIGNED BY: & 1949_RAING_[bd cl. r,2.3,8MC LINEAR ANALYSIS TEMPERAruRE .35 "65 1.5 6"0 Ig\ 15- 0 DESIGN I.EVEI A & B CONDITION NORMAT & UPSET 350 350 650 1 500 550 1 500 6000 6000 15000 15000 oF CONDITIONS OPERATING SIZE 350 IEVEI C TEVEI D E,MERGENCY FAUTTED 450 450 2000 8000 20000 500 850 2100 9000 22140 q I u c\ I \l o !- o o }J = 3tnr colcul.floir ce torl ddc lor thb producr ren prr{ororrd ln occoedcnco wllh: Moierlolr: \ As.m.e sECilON ilt.SUtStCnOil ilt COmAOil:tfT $l?lOr|ll (dctr C lrrr oad orooa lllo cl: -ri Mechanical Snubber: Pacific ll, lcientific Iaa 2 g 4 o FSffi? DR1501 l-t7) fuBEncEN-PArERsoN I;Effi I ttco*it BCNGEN?A'CNSON PIPESUPPOn? CORP. lolo catAcltl Dltl 3tlttt ot2te -u 3 xcr xtttttraG ! CONTROL REF. ,,^:'wutffi] t ^ NO. 2420 $l:r.t 1ot1 b ?Attllo. 2420 --l i 4ET j EF ra ?o gwrrfG RADIUS PARt toot TORQUE T' I n s r (A PSA SIZE "35 "65 1.5 PART NO. STK 1801104-05 4 (PsA- 1/4 ) 180r104-07 2; (PSA-1/2) 180 I 102-05 4 I ti 1 i 4 5 tln ,l 180 1 rO3-0? 6 5- PSA-3 ) 1801106-05 (PSA-3)' 15 (PSA-101 c B i ( 6 NOTES. A D 'l J 2 8 1 L I ) L L 4 .'* 2; I 1J 8 L MTN ,* 7.5 15 ll 4 E ,i 14.-t 3t 1'7 . *:t l=f, nin. * set DosiEion r r i b ru I I P It{ IN- R LBS. J ,* 9 2 R ^l F A r. I BY BP. $tzE 6,t5 q 8 ,l II 3+ I € I4 'i 2 I T S U 22 !I 1* 22 Z 1: B I2 11 2 : I I4 lI 7 1 8 1 45 1 120 ,i ,: ,1e i 440 1 T s l: rJ l4 3 8 Itt :l z :5 ,S ) l4 I 1. Rll dimensions are in inches. 2. Dimensions provided for user applicatj_L-on onlv. 3. Each PSA snubber has a scale to indicate the numlir of inches of extension. The scale is uncovered as the snubber is extended- To determine the scale reading (set position) at instaltation use the appli.cation formula. stroke - moyement (Use if thermaL movement from cold to hot will cause the snubber to extend. ) (Use if thernral movement from colcl + For retraction, set position - stro\e movement to hot will cause the snubber to ret.ract. ) For extension, set position 4. = This assenbly is compatible with BP Parrs 6175, 62Q2, 6252, 628Q, 6520 , 6es23, 6526, 6410, 1000. ORDERING INSTRUCIIONS 6521 , : Specify Part No., Load Capacity Data Sheet Rev. Irle-, Size Designition, .Stroke, Thernal Mvt. .(Extension or Retraction), "L". Dim., & P-P at S€C position - ex : 242O-R1'l -6 , stroke=S", tilvt=l-1/2" E:;f-t., L=l6", p-p.*18-t/4". BENGEN+ATERSC'N PIPE SUPPIOIT CORP. DATE 4-1-87 IOAD CAPACITY DATA SHEET lor NUCLEAI POWER PLAilT COT,IPOilEilT STAT{DAID SUPPONTS SHORT STRUT ASSEI{BI,Y WITH MSA BY PSC DIREC'ION OF LOADING LOAD RATING & DESIGNED 8Y: srzE. 50 120 LINEAR AIIALYSIS 0br.l cl. r,2.3, tMc DESIGN OPERATING rEvEt A t I LOAO RATING NORMA! CONDITION 50000 120000 1 t TEMPERATUR6 tEvE[ c IEVET D FAUTTED 72400 66600 50000 20000 o6 CONDITIONS EMERG€NCY UPSET 350 160000 1 Strrrt cokuldlont o?l.d lere podonnrd 60000 ff. ior filr producl ln ociordonco wlti: AJ-m.:. 3ECfl Oil fi . 3U!SCCnO!{ Hr ss: ut :, lt, I o c o fr' Pin: 5A-564, TYP. cbflFoilalfi 3rt?'o|t3 (dolr ol lttl,. 630 rad rrrcrl[e 7.1.77) ct: Mechanical Snubbbi! Pacific BERGEN.PATERSON Scientific. per PSC CDRS DR1601 LACOdrl ,t atua(qt corDutTo| NCd dttathtaa cJz.t CONTROL REF. NO. 2421 ttnGt lr.PAftrtoN PlPtsuPPOrt conP tolDCrrrclrl oeri $lttl , r- t 4 onorrEot zo FT-LBs l- nwll{o FAOltlg I A /r:-leuil llZE !'-ltUil FAFT t00t ,TL KIP SIZE PSA PART 50 !,1O. 18011i9-09 6 /psl- r nnr A B c 5e Mi1n D L E on* o5 ?* 6 tt; * L+ s* 24 6 45 '8 LI 8+ 29 tt ,8 * NOTES. 3, Dinensions are providgd 4- Each PSA Snubber has 12O - to + '+ a scale to indicate the T -5 5F 5 _L ,1i -L6 6 -1 -4 -16 t+ ,+ P-P (lutax) = P-P be torqued for user application S U w 4 L+ 9 + hln 3 1- Q=150 ft. lbs. Size 50 and Size 2- All dinensions are in inches. 'R r_P P' M min 6 1 rpsa- iq) t20 STK 12-09 1801 60 tlZE l2O .,L (tlin) + St,roke at installation. only. nurnber of inches of extension. is uncovered as the snubber is extencied. To deter:nine the scale reading (Set position) at installation, use the applicable .forrnuia. For extension, set position = Stroke-Movenent - (Use if therslal novernent from cold to ilot wiil 2 cause the snubber to The scale extend. ) For retracti.on, set position = Stroke + Movement- 2 (Use if thernal move!;rent from cold to hot uill cause the snubber to retract 5. This assereb'ly is conpatible'with . ) B/P Farts 6175, 6202, 6252, 628Q, 1000. Ordering Instructions : Specify Part No., Load Canacity Data Sheet Rev". No., Size designation, stroke, thermal novenent (Extension or Retraction), [Lrr Dimension, and Pin to Pin at set position. EXAITIPLE: Patt 2421-R/0, Stroke=6ri, l'lvt=2t' (P.etraction),L=28",P-P=58f' BGNGEilfATENSON PIPE SUPFOffi CONP. PAnf 242t IOAD CAPACITY DATA SHEET lor NUCLEAN POWEN PTANT COTiPONENT STANDARD SUPPOTTS STRUT ASSEI'IBLY WITH PSC MSA DlnECNON OF TOADINC OCSIGNEDBY: Linear Analysis S TRUT *a 7' 7t .35 .65 - 6 l5 0r' 1-2t - 0rr 6000 ltr nll 15000 50000 120000 - 13' - 50 l4r - 12o' o" 0rr 300 EMERGENCY FAUTTED 450 850 500 850 350 ott 0,t 550 !.500 l0' l-5 TEMpERATURS op O P E R A T I N'G C O N D I T IO N S r.EvEt c I,EVEt D tEvct A I I NORMAT & UPSEI LEN GTH stzE RAING (lbg.l cl. r.2.3,8MC LOAD 2000 8000 20000 66600 160000 2LOA 9000 22LOO 72400 160000 d 6 L o r, qt € k (u .-, 0{ c +r q, o Ff 0, rJ .J .b & A. .i* Max. strut length for rated Ioads shsrn with transverse acceleration ( lc Code Case N-55 lpplies. A ftlotorlob: Plate: sA36 , SA5I5Gr. Rod: 5A36'A108 Gr.1018 * pipe: SA.53. 6t.3 *(Co<ie Case i{ l:l tll D rA I E E o ^lirF6^ {.r"rrS Pin: 5A564 TYP. bolts: A574 (Code Case Nuts: SA3O7 Gr.B N-249 tlrrlr cdculdlorr cr tll r.r. drlo EEROEll-PAtEnSClll LC)IO Clract?l DltA llltlT lilr poducl A.t-mr. $cflo}l n. tursrctlor ilt )COFoilEm $t?om3 (dd. ol hr. 7-l.m cdcrlcrlllorr: M"rrGEN-PArERsoN I ?tzatatatca,/ril.tton x^aatdtre tarx^aatdtrE ot2.a.u L^CO'at.^ ta, 0t2.a.u CONTROL REF. NO. 2440 tlt/t;..orto 0or tarlonnoa In cccdorco wlilr: -- trfitr 1or I s a ^ J P-P(r2") PIPE FRW.35&.65 (NOM. DIA) BYBP USTOMER -1.5-15 M Y TA'r FRW (SW ING RADIUS} srzEs .95-15 w R BY BP \ 1 / QT (NOTE 4'. Q2 (NOTE 5'' P BY CUSTOMER L** E PIPE M l*s BY BP TYP. (NOM. DIA) TW Ll TT ol BY BP TYP.. (srzEs r s-i aoi Q2 L** BY BP stzEs 50&120 BY BP **.L_{ MINhSET POSITION .:,.-- THIS CONFIGURATION sr4Es so8120 oNLY KIP SIZE [ote D-D L PSC I PAnt ilo. B c .trll t{ rt 9 zl rI D E 3 0^ ,11""" rrilss s tlt u.Ax P 23 a4 rt, s/40 r5 2 -l 3 2l 84 7.5 aE 6 rt" s/40 I5 2 I rt zl 2 r$ rt 4 6 P !t IPE R rI STROKE T I U 7 .35 t80 r 104-05 I rI 1 3 7 6 .65 18011 o4-0? I rt 2 6 I z Q II { z L 23 L2( rt" sroo 35 4 z! 14.5 al 3 4 29 L41 et" srao 100 l0 2 zl 5 6 1 { r?. r sl t zl 3 6 r$ rI .5 z4 t6 6 -16 .1r rI 6 ^I -r6 r! I 1.5 l80rlo2-05 rt rI 3 h 6 r80r 106-05 zL6 -I .T rI r5 l80l 103-07 5 tl zI 50 r80ll12-rl fi 6 3 e$ e] t 120 t80rlr9-11 r16 3 5 E rf { ,o 6 C 3 6 34 144 3n s/80 100 36 rI q6 .56 5F S/80 100 150 'i { ,! 55 t68 8i roo r50 6 r6 '2 BERCEI{fATERSOil PIPE SUPP|ORT CORP. s/80 -l t6 lt DATE "n-rs-eJ 2 ie I 5 7 7 16 I 2 5 6 NOTES: 1. All dimensions are in inches. 2. Di:nensions are Provided for user aPglication onllz' 3. P-P uinirouu will be increased bv the set position' 4- Set P-P at desired position and tighten nut to nominal torgue "ttt" (=Qf) for locking. 5. Torgue at installation to nominal torque value t=QZ)' inches of extension6. Each pSA snubber has a scale to indicate the number of the scale To determine is extended. snubber the as uncovered is The scale formulaapPlicable the reading (set position) at installation use Forextension,setposi'tio,'=#.:ilu'|".ffiffil'l":il::..fi.' For retraction, set Position = snubber to extend. ) stroke + qolgneg! (use if thermal movement from cold to hot $rill cause the snubber to retract. ) 7. This assenbly is compatible with B-P Parts 10oo; 6L75,6202,6252' 6280,6525r 6526. ORDERING INSTRUCTIONS : specify Part. No., Load ca.pacity Data sheet Revision No' , Slze Designation. Slroke, Thermal Movement (Extension or Retraction), "L" Dimension, and P-P at set position. ( Pricing wilt be in two parts. ie: Attachnents and PSA urnits. ) Exanrple: ParL2440-R/'3- 6- StrOke = 5", Mvt. = 2" Ext" L=16tr' P-P= 36" BERGENfATERSON PIPE SUPP(ORT CORP. PARI 2440 DATE rI-r.g-sz ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) tit J' CDRS CATALOG INFORMATION SHEET d b SHORT HYDRAUUC S'I'U8BER ASSEI'BLY - PARr NUHBER 2826.6" fA L PART 1OO3 tB L fi:;:l$Mmffi* .,,,,,,utllJlll1,,,, A KIP SIZE 6 100 illfl, .,rrl|lt1/4\ 150 250 .,1611x" tgllP l}',il u'k&, ilrl.,sfiItll0 E P 13 3/8 71t4 161t2 14314 8718 21t2 21t2 18112 16 3/4 11 3 7 7/8nifilh|Ill'15 8 5/8*l{' D * R 1t16 7 3t8 P.P 55 57 114 61114 748 I5/8 T w 2 1116 2 1t16 2 5t16 1 112 1 112 2 Preset Equetion't Tendon = Stoke-Movement Compresslon = Stoke + Mqrvement in inches and torque in foot pounds. 2 irted lor user application only. 2" is compatible with B-P Parts 1000, 6175,6202,6252, and 6280. 2 maintenance manual lor installation and operation instructions. ' the P-P [rAX dimoGslon is b6ed o0 lhe Pisbn d cenEr strok8' 7.)'The Cy'inder Sfol6 21.2 x irowment. 6.) oRDERtirc [rsTRucIloils: gze D€signalion, Diruclirn (Comprcsion/fensbn), Specify: Part Number, CDRS RoYision Number, Kip Prulct ffd Movement EXA PLE: PrcImhw 2826{-R/0-100 lssue,ln7rlo Dirsdion = Tension Presct= 21/f I'lt l/r\l /t /] A BERGE U.POWER PIPE SUPPORTS, INC, /il Mwttt=11// SHEET I OF I REv. a PART NO. 2E2S6 lir J, CDRS CATALOG INFORMATION SHEET d E SHORT HYDRAUL'C STUBBERASSEI'BLY . PART NUMBER 282610" t- t A PART L R Swing 1OO3 Rad. fB L KIP SIZE tm 6 150 A '*hlh," rn'' t ,ir$iilI1/4"til 250 .rrlil$"' 1..0tlF' {,'u,$, D E P 13 3/8 7114 21n 16112 143t4 8718 18112 18 3/4 11 tn'qg$$.15 I5/ft*w l,il.*rflill6 P.P * w T R 601t2 7 3/8 2 1t16 2ffi 62ffi 7 3t8 2 1/16 3 66 1/2 I5/8 2 5/16 11t2 11t2 2 PF**,Equation'r Tenglon = Stoke-Movement Compreeelon = Stoke+ Movement in indtes and torque in loot Pounds, for user application only. 2: 2 is compatible with B-P Parts 1000, 6175,6202,6252, and 6280. 2 maintenance manual lor installation and operation instructions. ' dimalgm is basod on he Pist 1.2 x Mov€mcnt. Sfrols 6.) The P-P MAX 7.) The Cy'hder at slbr strcke : ORDERI]IG II{STRUGTIOIIS: sp€city: Part Numbsf, CDRS Revinlln Number, lcp sik6 D€ignalion, Dir€C{On (comPression/Tensbo), Pteset and Mo\iemenl. EIA /r\ ZT PLE: 282F1FR/['1m Di€c{00 = Tension PEset =11/4' MYmt=I1E /t /J BERG EN''POWER PIPE SUPPORT$, lNC. SHEET 1 OF r REv. a PART No. 2826.10 SPRING RATE INFORMATION SHEET HYDRAULIC STRUT ASSEMBLY with CLAMP 6202 Pipe Size 2 1/2 3 4 5 6 8 10 12 14 16 18 20 24 30 36 Pipe Size 2 1/2 3 4 5 6 8 10 12 14 16 18 20 24 30 36 6202-4k Clamp 1.14E+06 1.38E+06 1.25E+06 1.54E+06 1.05E+06 1.03E+06 7.55E+05 8.16E+05 6.78E+05 6.15E+05 5.71E+05 5.00E+05 6.06E+05 4.40E+05 3.74E+05 Max 66 1.84E+04 1.85E+04 1.84E+04 1.85E+04 1.84E+04 1.84E+04 1.83E+04 1.83E+04 1.82E+04 1.82E+04 1.81E+04 1.80E+04 1.81E+04 1.79E+04 1.78E+04 Size 2 (2,000 lbf) **Assy. Pin - Pin (inches) 50 1.85E+04 1.86E+04 1.86E+04 1.86E+04 1.85E+04 1.85E+04 1.84E+04 1.84E+04 1.83E+04 1.83E+04 1.82E+04 1.82E+04 1.83E+04 1.81E+04 1.79E+04 Min 38 1.86E+04 1.87E+04 1.87E+04 1.87E+04 1.86E+04 1.86E+04 1.85E+04 1.85E+04 1.84E+04 1.84E+04 1.84E+04 1.83E+04 1.84E+04 1.82E+04 1.80E+04 6202-4k Clamp 1.14E+06 1.38E+06 1.25E+06 1.54E+06 1.05E+06 1.03E+06 7.55E+05 8.16E+05 6.78E+05 6.15E+05 5.71E+05 5.00E+05 6.06E+05 4.40E+05 3.74E+05 Max 66 4.40E+04 4.43E+04 4.41E+04 4.44E+04 4.38E+04 4.38E+04 4.31E+04 4.33E+04 4.29E+04 4.26E+04 4.24E+04 4.19E+04 4.25E+04 4.14E+04 4.08E+04 Size 3 (3,000 lbf) **Assy. Pin - Pin (inches) 50 4.48E+04 4.51E+04 4.49E+04 4.52E+04 4.46E+04 4.46E+04 4.39E+04 4.41E+04 4.36E+04 4.33E+04 4.31E+04 4.26E+04 4.33E+04 4.21E+04 4.14E+04 Min 38 4.54E+04 4.57E+04 4.55E+04 4.58E+04 4.52E+04 4.52E+04 4.44E+04 4.46E+04 4.42E+04 4.39E+04 4.36E+04 4.32E+04 4.38E+04 4.26E+04 4.19E+04 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke. 4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 4 REV. 1 PART NO. 2830 SPRING RATE INFORMATION SHEET HYDRAULIC STRUT ASSEMBLY with CLAMP 6202 Pipe Size 3 4 5 6 8 10 12 14 16 18 20 24 30 32 36 Pipe Size 4 5 6 8 10 12 14 16 18 20 24 30 36 6202-12k Clamp 2.18E+06 2.22E+06 3.24E+06 2.55E+06 2.07E+06 2.14E+06 1.71E+06 1.45E+06 1.35E+06 1.15E+06 1.02E+06 8.33E+05 9.38E+05 6.52E+05 6.98E+05 Max 90 1.07E+05 1.07E+05 1.08E+05 1.07E+05 1.06E+05 1.07E+05 1.05E+05 1.04E+05 1.03E+05 1.02E+05 1.01E+05 9.88E+04 1.00E+05 9.57E+04 9.66E+04 Size 9 (9,000 lbf) **Assembly Pin - Pin (inches) 70 50 1.11E+05 1.15E+05 1.11E+05 1.15E+05 1.12E+05 1.17E+05 1.11E+05 1.16E+05 1.10E+05 1.14E+05 1.10E+05 1.15E+05 1.09E+05 1.13E+05 1.08E+05 1.12E+05 1.07E+05 1.11E+05 1.06E+05 1.10E+05 1.04E+05 1.08E+05 1.02E+05 1.06E+05 1.04E+05 1.07E+05 9.88E+04 1.02E+05 9.98E+04 1.03E+05 Min 43 1.16E+05 1.16E+05 1.18E+05 1.17E+05 1.16E+05 1.16E+05 1.15E+05 1.13E+05 1.13E+05 1.11E+05 1.10E+05 1.07E+05 1.09E+05 1.03E+05 1.04E+05 6202-25k Clamp 3.25E+06 3.62E+06 3.47E+06 2.98E+06 2.96E+05 2.78E+06 2.66E+06 2.38E+06 2.25E+06 2.07E+06 1.75E+06 1.27E+06 1.32E+06 Max 111 1.74E+05 1.75E+05 1.75E+05 1.73E+05 1.13E+05 1.72E+05 1.72E+05 1.71E+05 1.70E+05 1.69E+05 1.66E+05 1.61E+05 1.61E+05 Size 16 (16,000 lbf) **Assembly Pin - Pin (inches) 90 70 1.81E+05 1.88E+05 1.82E+05 1.89E+05 1.81E+05 1.88E+05 1.80E+05 1.87E+05 1.16E+05 1.19E+05 1.79E+05 1.86E+05 1.79E+05 1.85E+05 1.77E+05 1.84E+05 1.76E+05 1.83E+05 1.75E+05 1.82E+05 1.73E+05 1.79E+05 1.66E+05 1.72E+05 1.67E+05 1.73E+05 Min 47 1.96E+05 1.98E+05 1.97E+05 1.95E+05 1.22E+05 1.94E+05 1.94E+05 1.92E+05 1.91E+05 1.90E+05 1.87E+05 1.79E+05 1.80E+05 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke. 4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 2 OF 4 REV. 1 PART NO. 2830 SPRING RATE INFORMATION SHEET HYDRAULIC STRUT ASSEMBLY with CLAMP 6202 Pipe Size 4 5 6 8 10 12 14 16 18 20 24 30 36 Pipe Size 8 10 12 14 16 18 20 24 30 36 6202-25k Clamp 3.25E+06 3.62E+06 3.47E+06 2.98E+06 2.96E+05 2.78E+06 2.66E+06 2.38E+06 2.25E+06 2.07E+06 1.75E+06 1.27E+06 1.32E+06 6202-35k Clamp 4.27E+06 3.80E+06 3.18E+06 3.24E+06 2.78E+06 2.69E+06 2.27E+06 2.08E+06 1.88E+06 1.73E+06 Max 111 2.17E+05 2.18E+05 2.18E+05 2.16E+05 1.30E+05 2.15E+05 2.14E+05 2.12E+05 2.11E+05 2.09E+05 2.05E+05 1.96E+05 1.98E+05 Max 146 3.11E+05 3.08E+05 3.03E+05 3.04E+05 2.99E+05 2.98E+05 2.92E+05 2.89E+05 2.84E+05 2.81E+05 Size 25 (25,000 lbf) **Assembly Pin - Pin (inches) 90 70 2.28E+05 2.39E+05 2.29E+05 2.40E+05 2.29E+05 2.40E+05 2.26E+05 2.37E+05 1.34E+05 1.38E+05 2.25E+05 2.36E+05 2.24E+05 2.35E+05 2.22E+05 2.32E+05 2.21E+05 2.31E+05 2.19E+05 2.29E+05 2.15E+05 2.24E+05 2.05E+05 2.14E+05 2.06E+05 2.15E+05 Min 49 2.51E+05 2.53E+05 2.53E+05 2.50E+05 1.42E+05 2.48E+05 2.47E+05 2.45E+05 2.43E+05 2.41E+05 2.36E+05 2.24E+05 2.26E+05 Size 40 (40,000 lbf) ** Assembly Pin - Pin (inches) 120 100 80 60 3.27E+05 3.40E+05 3.55E+05 3.71E+05 3.24E+05 3.37E+05 3.52E+05 3.67E+05 3.18E+05 3.31E+05 3.45E+05 3.61E+05 3.19E+05 3.32E+05 3.46E+05 3.61E+05 3.14E+05 3.26E+05 3.40E+05 3.55E+05 3.13E+05 3.25E+05 3.39E+05 3.53E+05 3.06E+05 3.18E+05 3.31E+05 3.45E+05 3.02E+05 3.14E+05 3.27E+05 3.40E+05 2.98E+05 3.09E+05 3.21E+05 3.34E+05 2.94E+05 3.05E+05 3.17E+05 3.29E+05 Min 54 3.76E+05 3.72E+05 3.65E+05 3.66E+05 3.59E+05 3.58E+05 3.49E+05 3.45E+05 3.39E+05 3.33E+05 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke. 4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 3 OF 4 REV. 1 PART NO. 2830 SPRING RATE INFORMATION SHEET HYDRAULIC STRUT ASSEMBLY with CLAMP 6202 Pipe Size 10 12 14 16 18 20 24 30 36 6202-60k Clamp 5.04E+06 5.08E+06 4.69E+06 4.20E+06 4.41E+06 3.92E+06 3.39E+06 3.02E+06 2.48E+06 Max 170 4.25E+05 4.25E+05 4.22E+05 4.18E+05 4.20E+05 4.15E+05 4.08E+05 4.02E+05 3.91E+05 Size 60 (60,000 lbf) ** Assembly Pin - Pin (inches) 140 120 100 80 4.61E+05 4.89E+05 5.20E+05 5.55E+05 4.62E+05 4.89E+05 5.20E+05 5.56E+05 4.58E+05 4.85E+05 5.16E+05 5.51E+05 4.53E+05 4.79E+05 5.09E+05 5.43E+05 4.55E+05 4.82E+05 5.12E+05 5.47E+05 4.49E+05 4.76E+05 5.05E+05 5.38E+05 4.41E+05 4.67E+05 4.95E+05 5.27E+05 4.34E+05 4.59E+05 4.86E+05 5.17E+05 4.21E+05 4.44E+05 4.70E+05 4.99E+05 Min 58 6.00E+05 6.01E+05 5.95E+05 5.86E+05 5.90E+05 5.81E+05 5.67E+05 5.56E+05 5.34E+05 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke. 4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 4 OF 4 REV. 1 PART NO. 2830 SPRING RATE INFORMATION SHEET HYDRAULIC STRUT ASSEMBLY with CLAMP 6202 6202-80k Clamp 7.55E+06 6.67E+06 6.50E+06 5.80E+06 5.63E+06 4.76E+06 4.68E+06 3.79E+06 3.51E+06 Max 170 5.40E+05 5.35E+05 5.34E+05 5.29E+05 5.27E+05 5.18E+05 5.17E+05 5.04E+05 4.99E+05 Size 100 (100,000 lbf) ** Assembly Pin - Pin (inches) 140 120 100 80 5.67E+05 5.87E+05 6.08E+05 6.30E+05 5.62E+05 5.81E+05 6.01E+05 6.23E+05 5.60E+05 5.79E+05 6.00E+05 6.22E+05 5.55E+05 5.73E+05 5.93E+05 6.15E+05 5.53E+05 5.72E+05 5.91E+05 6.13E+05 5.43E+05 5.61E+05 5.80E+05 6.01E+05 5.42E+05 5.60E+05 5.79E+05 5.99E+05 5.28E+05 5.45E+05 5.63E+05 5.82E+05 5.22E+05 5.38E+05 5.56E+05 5.75E+05 Min 70 6.42E+05 6.35E+05 6.33E+05 6.26E+05 6.24E+05 6.11E+05 6.10E+05 5.92E+05 5.85E+05 Pipe Size 6202-130k Clamp 14 5.48E+06 16 5.19E+06 18 4.79E+06 20 4.44E+06 24 4.26E+06 30 3.74E+06 36 3.14E+06 Max 122 6.66E+05 6.61E+05 6.54E+05 6.48E+05 6.43E+05 6.30E+05 6.10E+05 Size 150 (150,000 lbf) ** Assembly Pin - Pin (inches) 110 100 90 80 6.82E+05 6.96E+05 7.10E+05 7.25E+05 6.77E+05 6.91E+05 7.05E+05 7.20E+05 6.70E+05 6.83E+05 6.97E+05 7.12E+05 6.63E+05 6.76E+05 6.89E+05 7.04E+05 6.58E+05 6.71E+05 6.85E+05 6.99E+05 6.45E+05 6.57E+05 6.70E+05 6.83E+05 6.24E+05 6.36E+05 6.48E+05 6.60E+05 Min 72 7.38E+05 7.33E+05 7.24E+05 7.16E+05 7.10E+05 6.94E+05 6.71E+05 Pipe Size 10 12 14 16 18 20 24 30 36 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke. 4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 2 REV. 1 PART NO. 2831 SPRING RATE INFORMATION SHEET HYDRAULIC STRUT ASSEMBLY with CLAMP 6202 Pipe Size 6202-200k Clamp 16 1.39E+07 18 1.38E+07 20 1.40E+07 24 1.31E+07 30 1.50E+07 36 1.50E+07 Max 122 9.61E+05 9.61E+05 9.62E+05 9.57E+05 9.66E+05 9.66E+05 Size 250 (250,000 lbf) ** Assembly Pin - Pin (inches) 110 100 90 80 9.81E+05 9.97E+05 1.01E+06 1.03E+06 9.80E+05 9.97E+05 1.01E+06 1.03E+06 9.81E+05 9.98E+05 1.02E+06 1.03E+06 9.76E+05 9.93E+05 1.01E+06 1.03E+06 9.86E+05 1.00E+06 1.02E+06 1.04E+06 9.86E+05 1.00E+06 1.02E+06 1.04E+06 Min 82 1.03E+06 1.03E+06 1.03E+06 1.02E+06 1.03E+06 1.03E+06 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke. 4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 2 OF 2 REV. 1 PART NO. 2831 SPRING RATE INFORMATION SHEET HYDRAULIC STRUT ASSEMBLY with CLAMP 6202 6202-80k Clamp 7.55E+06 6.67E+06 6.50E+06 5.80E+06 5.63E+06 4.76E+06 4.68E+06 3.79E+06 3.51E+06 Max 170 5.40E+05 5.35E+05 5.34E+05 5.29E+05 5.27E+05 5.18E+05 5.17E+05 5.04E+05 4.99E+05 Size 100 (100,000 lbf) ** Assembly Pin - Pin (inches) 140 120 100 80 5.67E+05 5.87E+05 6.08E+05 6.30E+05 5.62E+05 5.81E+05 6.01E+05 6.23E+05 5.60E+05 5.79E+05 6.00E+05 6.22E+05 5.55E+05 5.73E+05 5.93E+05 6.15E+05 5.53E+05 5.72E+05 5.91E+05 6.13E+05 5.43E+05 5.61E+05 5.80E+05 6.01E+05 5.42E+05 5.60E+05 5.79E+05 5.99E+05 5.28E+05 5.45E+05 5.63E+05 5.82E+05 5.22E+05 5.38E+05 5.56E+05 5.75E+05 Min 70 6.42E+05 6.35E+05 6.33E+05 6.26E+05 6.24E+05 6.11E+05 6.10E+05 5.92E+05 5.85E+05 Pipe Size 6202-130k Clamp 14 5.48E+06 16 5.19E+06 18 4.79E+06 20 4.44E+06 24 4.26E+06 30 3.74E+06 36 3.14E+06 Max 122 6.66E+05 6.61E+05 6.54E+05 6.48E+05 6.43E+05 6.30E+05 6.10E+05 Size 150 (150,000 lbf) ** Assembly Pin - Pin (inches) 110 100 90 80 6.82E+05 6.96E+05 7.10E+05 7.25E+05 6.77E+05 6.91E+05 7.05E+05 7.20E+05 6.70E+05 6.83E+05 6.97E+05 7.12E+05 6.63E+05 6.76E+05 6.89E+05 7.04E+05 6.58E+05 6.71E+05 6.85E+05 6.99E+05 6.45E+05 6.57E+05 6.70E+05 6.83E+05 6.24E+05 6.36E+05 6.48E+05 6.60E+05 Min 72 7.38E+05 7.33E+05 7.24E+05 7.16E+05 7.10E+05 6.94E+05 6.71E+05 Pipe Size 10 12 14 16 18 20 24 30 36 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke. 4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 2 REV. 1 PART NO. 2831 SPRING RATE INFORMATION SHEET HYDRAULIC STRUT ASSEMBLY with CLAMP 6202 Pipe Size 6202-200k Clamp 16 1.39E+07 18 1.38E+07 20 1.40E+07 24 1.31E+07 30 1.50E+07 36 1.50E+07 Max 122 9.61E+05 9.61E+05 9.62E+05 9.57E+05 9.66E+05 9.66E+05 Size 250 (250,000 lbf) ** Assembly Pin - Pin (inches) 110 100 90 80 9.81E+05 9.97E+05 1.01E+06 1.03E+06 9.80E+05 9.97E+05 1.01E+06 1.03E+06 9.81E+05 9.98E+05 1.02E+06 1.03E+06 9.76E+05 9.93E+05 1.01E+06 1.03E+06 9.86E+05 1.00E+06 1.02E+06 1.04E+06 9.86E+05 1.00E+06 1.02E+06 1.04E+06 Min 82 1.03E+06 1.03E+06 1.03E+06 1.02E+06 1.03E+06 1.03E+06 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke. 4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 2 OF 2 REV. 1 PART NO. 2831 SPRING RATE INFORMATION SHEET HYDRAULIC STRUT ASSEMBLY with YOKE CLAMP 6175 6175-80k Clamp 1.07E+07 1.14E+07 1.05E+07 9.52E+06 9.64E+06 7.69E+06 7.21E+06 6.61E+06 Max 170 5.52E+05 5.54E+05 5.51E+05 5.48E+05 5.49E+05 5.41E+05 5.38E+05 5.35E+05 Size 100 (100,000 lbf) ** Assembly Pin - Pin (inches) 140 120 100 80 5.80E+05 6.00E+05 6.22E+05 6.46E+05 5.82E+05 6.03E+05 6.25E+05 6.48E+05 5.79E+05 6.00E+05 6.22E+05 6.45E+05 5.76E+05 5.96E+05 6.18E+05 6.41E+05 5.76E+05 5.97E+05 6.18E+05 6.42E+05 5.68E+05 5.87E+05 6.08E+05 6.31E+05 5.65E+05 5.84E+05 6.05E+05 6.28E+05 5.61E+05 5.80E+05 6.01E+05 6.23E+05 Min 70 6.58E+05 6.61E+05 6.58E+05 6.53E+05 6.54E+05 6.43E+05 6.39E+05 6.34E+05 Pipe Size 6175-130k Clamp 14 9.64E+06 16 9.76E+06 18 8.89E+06 20 8.60E+06 24 7.55E+06 30 6.96E+06 36 5.80E+06 Max 120 7.03E+05 7.03E+05 6.98E+05 6.97E+05 6.89E+05 6.84E+05 6.70E+05 Size 150 (150,000 lbf) ** Assembly Pin - Pin (inches) 90 80 110 100 7.18E+05 7.33E+05 7.49E+05 7.66E+05 7.18E+05 7.34E+05 7.50E+05 7.67E+05 7.13E+05 7.28E+05 7.44E+05 7.61E+05 7.11E+05 7.26E+05 7.42E+05 7.59E+05 7.03E+05 7.18E+05 7.33E+05 7.49E+05 6.98E+05 7.12E+05 7.27E+05 7.43E+05 6.84E+05 6.98E+05 7.12E+05 7.28E+05 Min 72 7.80E+05 7.81E+05 7.75E+05 7.72E+05 7.63E+05 7.56E+05 7.40E+05 Pipe Size 12 14 16 18 20 24 30 36 NOTES: 1.) Spring Rates = lbs. / inch. ** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length. The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp. 3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke. 4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units. REVISIONS 0 1 2 Original Issue 9/21/10 Revised all Spring Rates 10/1/10 3 4 5 BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV. 1 PART NO. 2831 ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) lire GDRS CATALOG INFORMATION SHEET IfiECHANICAT SHORT STRUT. PART NUMBER 28ffi4" Swing Rad. 2 1/,16 11 7t16 Premt Eouation'r for user application only. compatible with B-P Parb 1()ff), 6175, 6202, 6252, and 6280. 4.1 * ' Tension = Stoke- Moveme,n! Compnsslon = Stoke+ Movement the maintenance manualfor installation and operation instructions. 5.) L=Lmin+SetPosition. 2 6.) P-P MlN. dimension based on the Snubber set at Zero on he scale. 2 ORDERIilO INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, Kip Size Designation, Direc{ion (Compression/Tension), Movement, the'L' dimension and Pin D$MPLE: 2860-4-R/0-9 . Pin at the set dimension. Direction = Tension Mvmt = 1112' L = 17 5/8" P'P = 20 7E REVTSTOf{S /o\ Aefminary lssue 4126110 /i /r\ /1\ J /z\ /i BERG EN.POWER PIPE SUPPORTS, INC. SHEEI 1 OF I REV. A PART NO. 2860"f ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) tflJ., dJ, J CDRS CATALOG INFORMATION SHEET i ITECHANICAI. SHORTSTRUT. PART NUTBER 2860.6" Swing Rad, I 11/16 4311116 51 15/16 Pnget Eouation'g for user application only. 'compatible witr B-P Parts '1000, 6175, 6202,6252, and 6280. 4) * 5,) Tentlon = Stohq -.Movement Comprerrion = Stoke +Movement the maintenance manualfor installation and operation insfuctions. 2 L=Lmin+SetPosition. . 6.) P-P MlN. dimension based on the Snubber set at Zero on fie scale. 2 ORDERING INSTRUCTIONE: Specity: Part Number, CDRS Revision Number, Kip Size Designation, Direction (Compression/Tension), Movement, ilre "L'dimension and Pin. Pin at the set dimension, DGITIPLE: 2860-6-R/0-g AlPnliminary lssp /l\ A 'f26li0 Direction = Tension Mvmt = 1112' L = 21" P-P = 24-114 l,/N /t /\ BERG EN.POWER PIPE SUPPORTS, INC, SHEET 1 OF I REv. a PART ltlO. 2860'6 ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) lit D' CDRS CATALOG d fl SHEET 'NFORIIIAT'ON TTECHANICAI SHORT STRUT- PART NU'TBER 2860-10" Swlrq Rad. 111t16 11 7116 Prcrt for user application only, compatible wifi B-P Parts 1000, 6175, 6202,6252, and 6280. 4,)Ri ' 5.)Di Tension = Stoke- Movement Comprecrion = 2 Stoke + Mowment he maintenance manualfor installation and operation instructions, L=Lmin+SetPosition. - 6.) P-P MlN. dimension based on he Snubber set at Zero on ttre scale, Equatlon'e 2 OROERING IilSTRUCTIONS: Specify: part Numbel, CDRS Revision Number, Kip Size Designation, Direction (Compression/Tension), Movement, he'L'dimension and Pin - Pin atthe set dimension. D(AMpLE: Z8O&10-R/0-9 /t\ A Direction = Tension Mvmt = 1 112' l= 2F112' P-P = 2S3/4' /t /J BERG EN-POWER PIPE SUPPORTS,//NC. SHEET 1 0F I Rry. A PART t{O. 2860-10 ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) tir I' CDRS CATALOG INFORMATION SHEET ? MECHANICAL LONG STRUT. PART NUMEER 28704" Part 1003 1* Palt 2850 Swing Rad. ifrn'-*ql KIP B stzE I 1 1 2 3 I 2 D E 1t2 1t2 3 2 5112 7t16 61/8 16 3 7112 25 31t2 40 4 3/8 11 60 ,l00 5 11/16 12 7 7t8 14 15{t 8 5/8 11 250 7116 8 Mtil 123t8 1?3t8 13t4 5/8 4 144 2 15 3/16 25t8 31t4 3/16 3 7/8 4 ,lr. s 7/81 ,*lllXUII/8 ri{lllNr,, Irrrr.. M -"luul p20 m3878 5'l '{t,tfr,,112'ni 3T'll 350'.?/16 .*ir,1 1'"lllilir,J.,'$ll{1 3/8 o QI R T w $r. 50 45 11t4 5/8 1t2 1t2 50 "rtIl59 ffi 50 45 45 11t4 11t4 5/8 5/8 1t2 1t2 314 5/8 100 120 2 718 76 9/16 1 100 120 2518 1 3/8 87 7t16 11t4 100 Afi 2 5/8 11t2 1 1023t4 1m 100 440 3 5/8 111t16 11t4 'il 4A 1t8 , ,P 1t2 29'T ''t{l&" PI Ih36 5/8 16 3/8'll$l'qffi0z 7/8'tt[lllr*1162 5/8 ,illiE,1/4 15 3/4.,rrllll} Srq!10. illtlllttnr slllilil**,.- 9/1ff1'r'1trhh.23 5718 2S$lp" P.FIII L 1 49 3/4 107 1U4 100 440 41t8 I 13/16 1 1t4 58 1/8 1241416 100 44 748 128 3t8 100 4N 7 3/8 723t4 154 3 100 440 I5/8 2 1/16 2 1116 2 5/16 11t2 61 2/3 21t2 21t2 1112 2 rl NOTES: tuque in foot pounds. 1.)Ail user application only. 2.) 5,)This 6.) Reler to at Preaet Eouetion's 2" adiustment. and tighted nut to the nominaltorque value (Q)br locking, is compatible with B-P parb 1000,6175, 6202, 6252,and6280. manual for installation and operation instructions. allow for 3.) P 4.) * 7,) Dimension L L min + Set Position. = ' 8.) P-P MlN. dimension based on Tension = Stoke-Movement Compreeslon = 2 Stoke + Movement tre Snubber set at Zero on the scab' 2 ORDERING INSTRUCTIONS: Part Number, CDRS Revision Number, Kip Size Designation, Direction (Compressim/Tension), Movement, the 'Ln dimension and Pin - Pin at he set dimension, Speciff HGIIPLE: 28704-R/0-9 Direction = Tension Mvmt = 1 llt L = 17 5/8" P'P = 34'1/8' RB/|S!ONS /; /r\ Prel imi narv lssue 4/26/1 0 /t\ /r\ /i A BERGEIV-POWER PIPE SUPPORTq, lNC. sHEEr 1 oF t REv. a PART NO. 2870-4 ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) CDRS CATALOG INFORMATION SHEET MECHANICAL LONG STRUT. PART NUITBER 2870.6" 1ffi3 Part Part 2850 lth.ull KIP B stzE 11t2 1 1 2 2 9 7t16 3 16 31t2 25 4 40 318 5 11/.16 60 100 7 7t8 150 I5/8 250 3 11 7116 25t8 31t4 71t2 37/8 3/16 20'1/js, ,{ilrH$r**l/4.F{llrdo 1/8 '0&'5/8 r. S$lil/$ 41 1'14 ,ffiirl#.. n 5718 12 14 3/4,d ill'' h, uri .Iffi,*uu,rf{l$ 4 g/16ltnlllltr,,, Z6,ql 11 15 *qufi|ld 14314 17 USrullll'. 31.Ii | 85 t/4"t1[lr*ll)'66 1/E 18314 1314 3t16 6 1/8 1l o'tllil$0 ll,.1l4 35{ 8i'Tlfl *7;314 ,'dhl1 "'ll ql 80 1/8 91 o Q1 R T 1t2 50 45 1t2 50 11t4 11t4 5/8 45 5/8 1n 50 45 114 5/8 1t2 1t2 3t4 I 100 120 2 7t8 5/8 100 120 25t8 1 3/8 100 u0 2 5/8 1 112 3 5/8 41t8 1 13/16 1114 1/16 1ffi 1t2 1114 46112 106 1/4 11t2 100 440 il. 52 1/4 110 5/8 1U4 100 440 61112 H',11/16 64 75 1283t8 131 ft8 157 112 w P Mtl#lfirrn r,,,,,.lllilll,,. 143t4 2 5ffi 8 lilN 13t4 5/8 4 1t2 2 3 E D P-P'rlffilho. L 21t2 21t2 3 I 1 1 11t4 11/16 100 MO 7 3/8 2 100 440 7 318 2 1t16 11t2 440 I 2 5/16 2 100 5/8 ,d NOTES: torque in foot pounds, 1.) All user application only. 2.1 3,) 4.) 5,)This 6.) Refer to t 2' adiustment. and tighted nut to the nominal torque value (Q) for loc*ing is compatible with B-P parts 1000,6175,6202, 6252,and 6280manual for installation and operation instructbns. allow for a * 7,) Dimension L = L min + Set Position, ' Preaet Eguatlon's Tension = Stoke' Movement Compretslon = Stoke +Movernent 2 2 8.) P-P MlN, dimension based on fte Snubber set at Zero on the scale. ORIIERING IT{SI RUCTIONS : Specify: part Number, CDRS Revision Number, Kip Size Designation, Direction (Compression/Tension), Movement, the "L' dimenSion and Pin - Pin at he set dimension' EXAilIPLE: 2870-6.R/0.9 Direction = Tension Mvmt = 1112' BERG EN.POWER PIPE SUPPORTS,'IUC. L = 21" P-P = 37-112' ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) lir *,, - CDRS CATALOG INFORMATION SHEET MECHANICAL LONG SIRUT. PART NUMBERaSTO-10" Part 1003 Swing Rad. -'uqililli llh' KIP D B slzE 1ffi I 1ffi 2 3 2 I 2 t6 7t16 3 I 25 31t2 {0 4 3/8 11 2 60 5 11/16 12 7 718 14 1flt I5/8 11 7t16 15 0 Q1 R T w 1t2 50 45 1t2 45 45 5/8 'g['l,7/8 50 50 11t4 11t4 5/8 1t2 1t2 1t4 5/8 1t2 1t2 8S U4"ll F1 7t16 3t4 100 120 2 718 5/8 3fi1iil5'rr 85 100 120 13/8 5/16 1 11/16 .38,4 5t16 221141 3114 3718 Mll*$ttlltr "l|Sr*/5 20 7/8xllllr, 35 S 3t16 25t8 3/16 100 18 18 #l*flI;1,6 b 261lllfl15{i Ilti ,{I11f,.'.1/4 srQtg. 3/4..rrl 2oillll"' .aiir11''tlj h 'n il4 OSur]flS ils 7t16 44 4'l8 961/4 444 111 5/8 11t4 11t2 100 50 100 440 3 5/8 55213 116 144 100 440 41tg 64 133 5/8 2112 100 440 7 3/8 417 137 1t4 21t2 100 440 7 3t8 78 5/8 1627t8 3 100 440 I5/8 3ltuil#tl 43n13116 ,u".'Mlilu 25t8 25t8 4 9/161"'{Illrr'291fi 'Str'7116"i 5 7/8 .d1 ri P tTtil 13t4 13t4 5/8 7112 3 250 E 4 5112 6 1/8 P-FIllllhL L 69 7t16 1 1 11t2 1 1114 11t4 1 13/16 2 1t16 2 1t16 2 5/16 1 112 1ffi 2 Ir NOTES: torque in foot pounds. 1.) All user application only. 2.) Di t 3) 4.1 5.)This allow for a 2' adjustment. :P and tighted nut lo the nominaltorque value (Q) for locking. is compatible witr B-P parts 1000, 6175,6202,6252, and 6280. manual for installation and operation instuctions. 6,) Refer to ' 7.) Dimension L = L min + Set Position, ' 8.) P-P MlN. dimension based on the Snubber set at Zero on the scale. Prsret Eouatont = Stoke- Movement 2 Compreoelon = Stgke t Movement Tenslon 2 ORDERIIII G IT{ST RUCTIONS: Specify: Part Number, CDRS Revision Number, Kip Size Designation, Directbn (Compression/Tension), nL* dimension and Pin - Pin at the set dimension. Movement, the DGIIPLE: /o\ n A ffi 2870-10-FU0-9 Direction = Tension Mvmt = l1l2' L=26-112" P-P = 43" REV|StONS J t\ /t BERG EN',POWER PIPE SUPPORIS, INC. SHEET 1 OF I REV, A PART NO. 2870.10 ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) UE}I I IFIEU UEsiI(iN HEP(JiI I 5UMMA]{Y for NUCLEAR POWER PLANT STANDARD SUPPORTS VARIAELE SUPPORT HANGER 31OO GE DIRECTION OF LOADING Temperature: ,IAAX. Note: e 7 E] The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DS-31OOGB RO DR.31OOGB RO DESIGN SPEC NO.: DESIGN REPORT NO.: a Rated Loads REV Size 350f . c-c MAx. 1 9',-2" 2 8"6" 3 4 5 6 7 8 9 10 7',-11" 7'.-5" 6'.9" 6',-2" 5"9" 5''3" 4',-9" 5'-8" 11 5"0" 12 4',-11" 13 14 15 4"8" 4"3" 4"8" 16 6'.11" 17 18 6''4" 5''9" Design Condition 196 260 OPERATING CONDITIONS Level A Level B Level C 196 196 260 196 260 344 260 344 458 610 810 1078 1434 1906 2534 3770 4480 5956 7380 10530 14000 18620 24750 for Classes 1,2,3 & MC 810 344 458 610 810 1078 1078 1434 1434 1906 1906 2534 2534 3770 4480 5956 7380 10530 14000 18620 24750 344 458 610 3770 44W 5956 7380 10530 14000 18520 24750 458 610 810 1078 1434 1906 2534 3770 4480 5956 7380 10530 14000 18620 24750 Test Condition Level D (see Note) 196 392 260 344 458 610 520 688 916 1220 810 1620 1078 1434 2156 2868 1906 3812 2534 3770 4480 5956 5068 7540 8960 11912 14760 21060 28000 37240 49500 7380 10530 14000 18620 24750 Thg tempelaturc as specilbd is rclatsd to tho mosl sEvore loadlng condltlon and doos not take into account the temperatjro eltect on the spring coil' ffifis-''d-rffi'l rquiremenb dth€ applcaue Cods. I The Design Report & Design Specification Materlals: N o o Plate. Load Pin & Channel: 5A-36 Studs: SA-36 Iurnbuckle: ASTM 4-668 CL C per CC N-71 o) IIJ f a o 2006 Addenda and are on file at Bergen Power Pipe Supports, lnc. J Product Engineerlng Depanment z Spring Coil Exempt (NF-1110) o (r o REV are in accordance with ASME Section lll, Subsection NF, 2004 Edition with CONTROLREFNO. 31OO Certification BERGEN.POWER PIPE SUPPORTS, INC. Sheet REV. 1of1 /O\ PART NO. 3100-GB VARIABLE SUPPORT HANGER 31OO GB HETGHT AT AAAX LOAD li I stzE A 1t2 1t2 1t2 1t2 1t2 1t2 5t8 5t8 1 2 3 4 5 6 7 8 9 10 REV NO to K 4 3t8 47t8 4 4 7t8 4 7t8 5 5/8 5 5/8 5 5/8 6 5/8 6 5/8 6 5/8 6 5/8 6 5/8 I 5/8 8 5/8 8 5/8 8 5/8 11 5/8 11 5/8 11 5/8 11 5/8 11 3/8 11 3/8 12 12 12 15 15 16 318 4 314 4 314 5 5 5/8 3t4 61t2 314 1 6112 6718 1 7 1 1114 1114 11t2 11t2 3100-68 c B 5112 5112 6112 11 12 13 14 15 16 17 18 Lc 118 81/8 8 7t8 91/8 10114 11 5/8 101/8 101/8 101/8 N w z c-c MAx. 3 3 3 3 3 3 9'-2" 8'-6" 87t8 314 I7 t8 3t4 87t8 314 8 7t8 314 I5/8 I5/8 314 91/8 91/8 91/8 161/8 161t2 21 181t2 19 3/8 1 3 1 3 3 4 4 4 4 4 4 1 12 12 1 127t8 1 1t2 1 112 1 112 127 t8 13 13 114 17 1t4 16 3/4 314 15 15 5/8 1 'l 112 7',-11" 7',-5" 6'-9" 6'-2" 5''9" 5'-3" 4'-9" 5',-8" 5t'0" 4'-11" 4'-8" 4'-3" 4'-9" 6'-11" 7 2 2 6t'4" 7 7 2112 5r-orr 1. All dimensions are in inches. 2. Dimensions are orovided for user application onlv. 3. This product is of welded construction. Q o, ]U J o a J z o tr o ORDERING INSTRUCTIONS : Specify Part No.; CDRS Rev. No., Size & Designation. Also Operating Load (HL), Thermal Mvt. & Direction (Up or Down) from Cold to Hot & C'C Dim. EXAMPLE: 3100-GB-R/0- 6 HL = 373#; MVT. ar ; Cto C = 2"0" I REV ET H =1l4" DOWN BERG EN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART DATE SHEET 1 OF 2 31OO.GB 9t112007 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS / --., ffi \,.' f \ ill fl \ 3?oo-GB I]c-c_ I DIRECTION OF l LOADING Temperature: 350oF tr11AX. Note: The temperature shown above is for Design and Operating Conditions. For the Test Gondition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DS.3lOOGB DESIGN SPEC NO.: DESIGN REPORT NO.: I g'-2" 8'-6" | 5 | | 7'-5" 6'-9" ffi + 5'-9" I | | | I | g | 10 | 11 | 12 | tg I | | |- | 16 | 17 | 1g | z m | 4 ffi | 7 ffi l Rated Loads (lbs) lor Classes 1,2,3 & MC oPERAnNGcoNDrnoNS ffi r,onqluo" I (.tee Nure, I t-t- lgqalg++lgqqlgqqlgttloeall lcsel45s1458 1458 letolsrol610l610l610l1220ll I 1458 1916 lsrolarolSl0larolsroltezoll I I rozs I rozs I rozs I roze I toze 1434 ll I , , , llgq 1e06 zssq 3T7O 4480 sgse I | I | | I I | I | | | 1434 1e06 zsgq 3r7O 4480 5e56 I | I | | | 1434 1e06 2534 3770 4480 5e56 I | | | | | 1e06 2534 3770 4480 5e56 | | | | | | zgeo I zgso I zgso I zseo I zgeo I I 10s30 10530 10530 10530 tosgo 4'-8" | | I tcooo I 6'-11" I rsszo I 6'-4" 5'-9" I zqtso I , ll;gt 1so6 zsgt 3770 4480 sgse , | | | rqooo I 14000 I 14000 I reezo I 18620 I 18620 I z+zso I 24750 I 24750 I | 14000 I 18620 I 24750 I ztso | 2868 3812 5068 7540 8e60 11e12 | | | | | | tlzeo | 21060 28000 |I 37240 | 49500 | 'l *The temperat ure as specified is related to the most severe loading condition and does not take into accounl the temperatut re effect on the spring coil. cenrry rnrs uuHD requirements of the applicable Code. r "oroffi The Design Report & Design Specification ilaterials: to o )late, Load Pin & Channel: 54-36 Studs:5A-36 o) t! lq lurnbuckle:ASTM A-668 CL C per CC are in accordance with ASME BPVC Section lll Subsection NF, 2007 Edition and are on file at N-71 a furgen Power Pipe Supports, lnc. J Product Engineering llepartment z (5 Spring (r Coil Exempt (NF-1110) coNTRoLREF o BERGEN.POWER PIPE SUPPORTS, INC. REV Certification I L--!- I 4'-9" | 5'-8" I 5'-0" | 4'-11" | 4'-8" It----.! ffi | ls RO DR-31OOGB RO Itt "*T-".u*. | 1 | I * Sheet l-of l- NO. 32OO REV. PART NO. ,6. 3200-GB | I | I | | | | | I I I I VARIABLE SUPPORT HANGER 32OO GB c-c l HETGHT AT ,IAAX LOAD t l w Fc- 3200-GB i A 1t2 1t2 1t2 1t2 1t2 1t2 SIZE 1 2 3 4 5 6 REV 7 6 5/8 6 5/8 7 114 7 1t4 7 718 7 7t8 81t2 I I 5/8 5/8 5/8 I3t4 10 3t4 I314 11 314 I3t4 8112 5 5 5 6 6 6 6 6 5/8 5/8 5/8 5/8 5/8 5/8 5/8 5/8 1 1t2 1 112 15 314 17 5t8 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 314 314 3t4 314 11t2 24 2 2 257t8 19 7t8 21t2 10 1/8 10 1/8 10 1/8 17 3t4 3t4 16 1t2 16 314 18114 18 1t2 13 718 I5/8 129t8 123t8 129t8 123t8 121t8 121t8 1112 1 112 21 1t2 21 3t4 11 1 z 157t8 161/8 197t8 197t8 8 5/8 1 W 1 12 318 13 314 10 3/8 N 12 5t8 12 5t8 12 5t8 15 3/8 15 3/8 20 5t8 1 18 4718 47t8 47t8 K 16 5/8 16 5/8 16 5/8 16 5/8 16 3/8 16 3/8 17 1t8 17 1t8 17 118 I5/8 I5/8 12 13 14 15 16 11t4 11t4 c B 207t8 231t2 1 1 1 I 1 112 c-c MAx. 9',-2" 8'-6" 7',-11" 7'-5" 6'-9" 6',-2" 5'-9" 5'-3" 4'-9" 5"8" 5"0" 4',-11" 4'-8" 4'-3" 4"8" 6'-11" 6'-4" 5'-9" 7 7 7 lO 1. All dimensions are in inches. to o 2. Dimensions are orovided for user application onlv. 3. This product is of welded construction. o, l )RDERING INSTRUCTIONS : a a Specify Pafi No.; CDRS Rev. No., Size & Designation. Also Operating Load (HL), Thermal Mvt. J & Direction (Up or Down) from Gold to Hot & C'C Dim. TU z g tr o EXAMPLE: 3200-GB-R/0-6 HL= 373#; MVT. =114" DOWN; GtoC=2"0" ffi REV Ef, fr B ERG EN-POWER PI PE SU PPOBTS CDRS CATALOG INFORMATION SHEET PART DATE 32OO.GB 9t1t2007 CERTIFIED DESIGN REPORT SUMMARY lor NUCLEAR POWER PLANT STANDARD SUPPORTS TAHIABLE SUPPORT HANGER 34OO GB 3400-GB DIRECTION OF c-c LOADING A,IAX. Note: K * The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Gondition. DESIGN SPEC {! Temperature: 350oF NO.: NO.: DESIGN REPORT DS.31OOGB RO DR-31OOGB RO Rated Loads (lbs) for Classes 1,2,3 & MC REV Size c-c MAx. 1 2 3 4 5 6 OPERATING CONDITIONS Design Condition Level A Level B Level C Level D g'.-2" 196 195 8'-6" 260 260 196 260 196 260 196 260 TEST CONDITION (See Note) 392 520 688 916 7',-11 344 344 344 344 344 7"5" It58 458 610 610 810 5''9" 458 610 810 1078 810 1078 458 610 810 1078 458 610 810 1078 5'-3" 1434 1434 1434 1434 1434 9 10 4''9" 5''8" 1906 1906 1906 1906 1906 3812 253/. 5'-0" 2534 3770 2534 3770 2534 3770 5068 11 2534 3770 12 13 4'-l1" 6''4" 4480 5956 7380 10530 14000 18620 44J,,0 18620 4480 5956 7380 10530 14000 18620 4480 5956 7380 10530 14000 18620 4480 5956 7380 10530 14000 18620 5'-9" 24750 24750 24750 24750 24750 6'-9" 6'-2" 7 I 4'-8" 4'-3" 4t'8" 14 15 16 6'-11 17 18 1078 3770 5956 7380 10530 1lm00 1220 1620 2156 2868 7540 8960 11912 14760 21060 28000 37240 49500 *The temperature as specified is related to the most severe loading condition and does not take into accou the temperature effect on the spring coil. I certity this CDRS complies with the I requirements of the applicable Code. I Materials: t\ o Plate, Load Pin & Channel: 54-36 a o, Studs:5A-36 uJ The Design Report & Design Specification are in accordance with ASME Section lll, Subsection NF, 2004 Edition with 2006 Addenda and are on file at Bergen Power Plpe Suqqorts, Inc. Turnbuckle:ASTM A-668 CL C per CC N-71 f a o J Product Engineering DePartment o = Sprins Coil Exempt (NF-1 1 10) E 3ONTROL REF o Sheel BERGEN.POWER PIPE SUPPORTS, INC. REV Certilication 1of 1 NO. 34OO REV. PART NO. /N 3400-GB VARIABLE SUPPORT HANGER 31OO GB i.+ I HEIGHT AT c-c AAAX LOAD / t_ w 3400-GB A SIZE REV B 1t2 1t2 1 112 11 2 1t2 1t2 1t2 1t2 1t2 11 I 5/8 5/8 14112 I 5t8 10 314 17 17 11 3t4 3 4 5 6 12 114 12 1t4 13 3t4 13 3t4 c K N w z 4 718 19 7t8 137t8 3t4 3 3 3 3 3 3 3 3 3 47t8 47t8 5 5/8 5 5/8 5 5/8 12 13 14 15 16 1 1114 23 6 5/8 6 5/8 6 5/8 6 5/8 6 5/8 8 5/8 8 5/8 I 5/8 I 5/8 10 1/8 17 18 1 112 1 112 27 30 101/8 101/8 7 1 1 11t4 141t2 17 18 18 114 20 3t4 23112 197t8 13 718 314 19 7t8 19 7t8 137t8 137t8 3t4 3t4 19 5/8 19 5/8 13 5/8 13 5/8 314 19 7t8 19 718 137t8 137t8 137t8 197t8 227t8 227t8 24 3t8 24 3t8 241t2 24 3t4 29 114 27 1t2 28 5t8 3t4 1 1 1 16 5/8 16 5/8 17 7t8 17 7t8 18 18 114 22 20 2 2 21 118 21t2 c-c 8'-6" 7',-11" 7'.-5" 6"9" 6',-2" 5'-9" 5'-3" 4'-9" 5"8" 5"0" 4 4 4 4 4 4 7 7 7 1 1 1 112 1 1t2 1 112 1 112 MAx. 9',-2" 4',-11" 4'-9" 4'-3" 4"8" 6'-11" 6'-4" 5'-9" lO 1. All dimensions are in inches. F- 2. Dimensions are provided for user application onlv. 3. This product is of welded construction. o o d lrJ f )RDERING INSTRUCTIONS: o a Specify Part No.; CDRS Rev. No., Size & Designation. Also Operating Load (HL), Thermal Mvt. J & Direction (Up or Down) from Gold to Hot & C'C Dim. z g tr o EXAMPLE: 3400-GB-R/0-O HL= 373#; MVT. =114" DOWN; CtoC=2'-0" I REV ET H BERG EN-POWER PI PE SU PPOBTS CDRS CATALOG INFORMATION SHEET PART DATE SHEET 1 OF 2 34OO.GB 911t2007 f.rtttttt IOAD CAPACITY DATA [or SHEET NUCTEAR POWER PTANT COIAPONENT STANDARD SUPPORTS CONSTANT SUPPORT HANGER DIRECTION OF TOADING DESIGNED BY: LOAD RATING_(lh,s.) cl. r, 2. 3, t Mc Linear Analysis TEMpERATURE 3 5 0* oF CONDITIONS OPERATING DESIGN I clrr> LEVEI. A & 8 NORMAI & UPSET CONDITION stzE 3 4 5 6 7 TEVEL D FAUTTED 130 17s 235 325 445 500 755 130 130 L75 235 325 445 600 755 2 TEVEL C EMERGENCY L75 235 32s 44s 600 755 130 17s 235 325 445 600 755 in inches- ltA"YIMtrM RATED InAD in pounds FoR EAGI SIZE (lhe ninimqsr load is the load for the preceeding size- Ex: the full for size 5 at 5" tR. is frorn 110* to lsOlt) TOTAL TRAI/EL Loads shown permit stress values. * '^'i \ /'t 3e> tlt f rJ a/, .t, @ -l 9R &l oN Load t,/' tft' load field adjustnent of up to t 15t without exceeding allowable rating for all components except for temperature effect on spring coil. Molcrlolt: 5A-36, SA-307GrB SA-193GrB7 A-668CL I or F A-108-Gr10t8** ** 3lmrr colculctlonr or lod ddo lor thh producl wrn prdormod ln occordoncr wlth: A.S*tr.E. SECTION lll -SUlSECrlON il; COllPOl{EilT SUP"OITS (dorr of lnoo 7.1.771 oad orron llb ot: , (Spring coil, bearings, washers' rinqs M"ERGEN-PA,ER*,N ruW LA CON tA. NEJt tl^atrSH exempt NF-2L?I) **Code Case lJ-71 coNTROt EENGEN.PATERSON PIPESUPPORT CORP. IOAD CAPACIIY DATA 3HC3I REF. NO. SlrcEf t A E 0t2.6 U, S a. 4000 ro;lo /0- PATTilO. 4000 sttEs 1-? lldtgEf, Srzl l-l a-? ? BT 1i. aL tit BI lL rf, ti. D G 2; I 2 t 2 z| 2 i I 2 I 2 E 7 at r t 2e 7 1 el I ri I 'For tLr I + lrrr .1r.. 5 to 7 tlrrcd rrqutruntF ?' l-i. thr.d f.ottb tor 9310 Fil OnDBrnt tISlGlIClSr tatlFtl at ?ae tl al rnd th IElcl|.t_ frr- tEiilf rzr l 3 t I tri .L tt I I ao rrl. I sl t 26 21 I sf ao l5 I d 2 rod ll'ntcr tt 2l ,t ZL E t t i 5P'. BENCEN+ATENSO}I PIPE SUPrcRT G(ORP. (lDPloI.l rmronr I 2 ri I?PGS (tll thc.dr ottlqrel co.n PART 12 40oo fltl . IOAD CAPACITY DATA SHEET for TUGIEAN FOWER PTAT'IT COMPOiIENT STANDAND SUPPOffiI CONSTANT SUPPORT HANGER 4000-A1 4 00 400 4000-c1 0-81 F 4000-Dl ! 0-Bla Dnccnolt OF toADll{o Linear Analvsis rr-- IOAO nAnNG flbcJ cl. 1,2.3, tl,lc TEMpERATURE OPERATING srzE NORTAAT CONDMON I t 905 905 9 rc90 10 13 10 13 10 L2 1465 L620 L465 L620 1I C E,TAERGENCY UPSET r090 CONDITIONS Level Level A & B OESIGN 350*-op Level 0 FAUTTED NOT APPLICABLE total t,rave I Tabulated loads shown are maxirnum rated values at mini-mum on Sheets Table Selection Size to Refer size. unit each offered for g & 10 for Load-Travel combinations ' Loadsshovrrperuiifieldloadadjustmen!ofuPtoJl5lwithoutexceeding al.I,owable stress values. *Load rating for all components except for temperature effect on sPring coil. 3={:36 5A-!9ZE A-519 Gr 10!.8 Cl'j** A.-553 CLC & F** tlrrrr crlnJrtlat tlrrr d.0.lotr{rlr 9€4lst rrr pedmrrd h rcrldrecr wllh: A.3-r.:. Stcne{ n -3u]3tctKrr ilt CWtDrl:flT $.FFOII3 (dci. ol lrrrr t'l'77) A-108 Gr 1014a SA-193 Gr 87 & SA-194 Gr rino coil beari W"W ffia* trl J (n cn (\ r- HI C'\ rl CIN F{ F{ & o --i:;!c-rT i r"ne l,.= =S =,1 flAtru =--*,'/nonuil iR =rffi srlr le-1-17 sEP ffiF,212! ' 2H n,a..._9tth*- **Code Case 1644-6 Control Ref. $fir ATERIiC'II PIPCSUPFONT CORP. ? LOTD CA'ACI'Y DA'A $ltrl etla 'TR6CN+ No. 4000 oEtctQ. r." I rycD !o lrr llLBllllctrtE a'l $''om30 Eof aal HAI.IGERSIZE t- c Bt tz a'-r. rolc.ogl ir t llcriot,r- dirronlicr. fr; t'at?-' F G g/. T *".:ED tilr ElrElrttrrtra.a DIrrEXSIONS in lnchcs N It L t lt c.L l'/, l'/. !|. 2 ^EYE lfi. (Aeeor.) Lbr. s So T w 7'.l. Ncr 5hc. 60 75 dirnrlorr Dlmenciom Provl&d R fbcrfpilcado t = Fa Only x nod Selcctton-thc tot.l tleld lord tord rlruld !tr|uts rn rddltloml t5l for D6stblc il,,illtl^gt th'crds mtromr corrtt fz rrt)' 'djuttllnt Ri:"hl?:9.:TrHlh:',rffi BERGEN+ATCISON PIPC SUPPORT CORP. FOR ORDERI I.IG I NSTRUCT T ONS SEE SHEETS 9 &10 PARr 4OOO DAIE 8-18-8s LOAD CAPACTTY DATA SHEET lor NUGI,EAT POWEN PTANT COXIPC'NET.IT $fAilDARD SUP?ONTS CONSTANT SUPPORT HAT{GER :: i- FI h* V 4 ! J {000{1 000-81 4 0 00-BIa ooo-A1 4 4 000-Dl DINCCilOl{ OF TOADING DESIGT{S tY: 13 18 10 t4 I5 2240 1810 2 000 2240 247 5 277 A 247 5 271 0 340 0 20 37 35 4729_ 2l I o fn I N c-l 4500 4950 5 400 5940 6480 22 23 24 25 26 27 28 5 Level c Eriehbixcv 3060 3400 3735 4L20 4500 495A s4 00 59 40 648 0 5710 6234 3060 I9 TEITPERATURE 35.d,OT OPERAI ING CONDITIONS NORIAAL ccrNDlncrN 16 L7 18 r\ t\ cl. l, 2, 3, t lAc &ea LevelI UPS T D€SIGN srzE IOAD RAflNG flbf.) Li,near furalvs i s 7I0 6230 Level A ra D I FAULTED L9) 2240 18l.n 2000 ?240 z:47 5 t i?'c 18 10 2t00 277 s 277 0 30,50 3{,0 0 37,35 r00 t) 3ro0 495 0 1735 1120 4500 4 950 5400 54m 594 0 59{O 648 0 64 8I) 4:l2O 4500 5;7L 0 sTlo 62'30 6 230 rated.values at minimum total travel tabulated load! shown are maximrur Table on sheetg of,fered for eacb o"it litt'-- nefer to size seiection ;-;-10-ia; Ioac-Travel cobinationg' to + t5t ttj'thout exceedIoadE shoen Per.mj.t field load adjusuBent of, up ing atloable stress values ' *I€ad ratlng for all conPonents excePt for iemPerature effect on sPr:'ng coil. A-568 CLC .9 Fthhda t:fse-til-ffitrde Qggg-H-Z,l SA-193 Gr 87 14 st glF Hf- I Ci \o HI Eto ,# l.Ar z / a/z Sorinq coil beariogS, washers Slnr cdadcttcr ct t .t dcll ior lill prodrrl wur fer{ccnrd la ecccrdncrwlltl l3.I.1.3rctKf,l l[ -3utslcnoil ilt COillOll0ff 3lt?tO[t! (dc.. c{ lgro 7.1.77) ndrroerlFcti W control Ref. llo. - COIP. t:noal.PArER3oH PIP:SUPFOS| tlltlll to^Dclt crroltA 3HEf ?- or lo 4000 PAtt llct. 4000 #s J Lb ioo tArE-out Prodrct of wscd Cmr&rc{on ITiFtsT I orefiqr gaD lo raY lrr aalrialggtlnll I Er Hlrt{It FE6cl fwFpr-llmvt ttE Jttort[o G,il I l' llrt: I IrrnE'|rr Al t Blo HAIGER SIZE 13. tt 5V, It.a lftf Itt 5t/t CV, SlttorrtD -lii- (A-.or-l I hr. Dilt ]ti ffi a ?p€ lt/, 14 t/, ,ta v, ta Slrorg. l3l 150 l8 200 81, cl ADI HGR. SIZE up lrovrl, dirnonrlonr rhorn lhould t tlorarun dknorler lor 7anP. 13. ,r .a noo olereten 16 11.79 rt/.-(tat2le, -(&3 rnl tnt 2t- ol' t7.-(2 Tn) |,/.-lla.t? 4t4.t rRl TRI l6-tz-''ArRl -(.{!4 rRt I 7.-(7.12 TO --Dlrebo tbcr APD[cado otttY FOR ORDERTNG INSTRUCTIONS SEE SHEETS BEROI}I+ATTTSO}I PIPI 3I.IPPogT GOTP. ProvldFor .9 E I,O DATE 8-2T-C2 LOAD CAPACITY DATA SHEET M,CI.EAT PC'WET PtAffi lor COTIPONENT STAIIIDARD SI.l?PONns CONSTANT SUPPORT HANGER 4000-81 4000-A1 400 F 4000-c1 ! 4000-D1 0-Bla DnEcrroN o; tOADlllG DESIGNED BY: Linear Analvsis roeo nenxc nu.t cl. l. 2, 3, & MC __j OPERATING srzE f\ F a: t o c3 I (Vt ac I @ (\t F{ 29 30 31 32 33 34 35 36 Level A & oeircN coNofnof{ 684 5 7 645 8650 NORr,lAt z 645 86 50 9480 r05 15 I17 00 7 10515 117 00 107 00 11750 Shown EMERGENCT UPSET r# D FAUTTED z - -9 E H F l-{ c) rlt \- r 11750 rnaximum Level -i 107 00 are 350*oP CONDITIONS Level C B 684 5 9{80 abulated loads I TETAPERATSP ru L.l rated values at minimrrn total travel offered for each unit size. Refer 'r-o Si-ze Selection Table on Sheets 9 & 10 for Load-Travel cornbinations. Loads shown pernit field load adjustrnent of up to I lst without exceeding allowable stress valuesiLoad rating for all comPonents except for temperature eifect on spring i]. . o L A-519 611018 C!{** A-668 CLC & F** r 1018** tr ('Jr\ vtt t{ rt rr{ ol l'.t o &,d o $il crlrrdc{or oe tret a.t lc" thh pcArcl rre fdcmd h rcordlrcr ;llh: A.s.*L 3GItO?a n -$Ngrctrtil ilt COpOilttff 3lJt?OfG (dob ol hnr 7'l'74) sndrrcllilrct- SA-193 Gr 87 Sori nq coi 1 beari nQs J{alh€r! s exempt i{F, **Code Case 1644-6 ontrol BINCT*PATERSON PIPESUPFOffi CORP. to^ocltrclw Dlll $ltt? Ref. No. - 4000 i-R #,Tr I I G w ol I R t@ Prcdrct ot wdftd Cotrrmcton lEregil % +Ci ffi! oncln ral I InlD ro rtt rttlf,L^?.|.o.'mw tffiT [trfli ''-..-H Er Ll *T3- ITffiI I TDI tll'lrcr E? IN it rim turtomfe Gfl EEnFttElrry.! ; Rca-riil.cor li-trot ilin rrrvrl (ccld rc t lfurtrrn dirroria lc reqrr.. . .Bl, cl eDl lrcn. stzE 29-tf, no'o tt c )L DtAnETET__(n 29 -3f2 3l I h-r:=fypEpr I tFE grprofircD rtorf. tl;ltl rhoold 5o iocreorod by cclucl lrcvrl dhcaricrrr. D F H a T 7 DlrfFXSlO}lS lr lnchrr 3 3o x T t lrr JA */. lrl, r% 3L t!A x l!-Gep-:erJut. llrt U Y U ltA I t2i.a Dt-;L* .36 r16-t2'+r rnl t'4-0'#3 TRI rU-{3,t,-.UTRI t7.-(rr&s rnl rnt | -(5%16 rRl t%-tS-Z'{ I -.r-ra tRl noc setdiitor.-tiii tout to.a grotd i*rucr.i tiitrdilITst urd th. nlght of thr urrlt for type Al only' iiiiit-nii i il'riiti- id' i. r. u'iii rinitrr' irlt tt'@ T I 3$- 3t0 3.0 Prrovtdcd For tbcr Appficafrm ()rrtY FOR ORDERING INSTRUCTIONS tor p:rlbtc rlcld lord dJul*rt - BERGEN+ATTIR'I'Oil PIPE 3U PFORT GORP. SEESHEETSg&10 PARr 4OOO DATE 8- 1.8-83 TOAD CAPACITY DATA SHEET lflr€tEAt POWEn lor H.Affi comP{oNENT STANOARD SUPPOnnS CONSTANT SUPPORT HANGER El i Io #.Jil ? 4000-81 4000-Al 4 4ooo-cL F ! 4000-DI - 000-BIa DINECNON OF tOADIilG Oe16NEgy, Linear Analvsis DESIGN rl I (lbr.l LOAD RAnNG cl. l,2,3,&lc OPERATING Level A srzE CONDMON NORAAAT & UPSET 37 38 1305 5 4 3s0 13055 39 40 1598s t7615 ffi 4l l9 19 10 CONDITIONS Level Leve I B 22L80 24000 46 23250 C EMERGENCT FAUTTED z IItJfU i5-eE'5 o zo 3ro E }' tt vU H ra E r{ H 1000 22L80 24000 21700 21250 2 42 43 44 45 350*oP TEMPERATURE H v@ o }'td trl H (1 F rl - at llinlmum total tf,avel Eabulated loads shown are maxlnqa rated-values Refer ro size selection rable on sheets ,roit ;E;;Al";-"icr, coobinations ' t-e-10 for r.ad-Travel"i".. IoadssbownperritfleldloadadjustmentofuPtoll5twithoutexceedvalues ing allowable stress ' *tpadratingforallcouPonentsexceptfortenPeratureeffectonspring coil. ffi;'-A-35, -Ir> ?-t o -I r* +{ Q t{ f\ t\ rl Ci tn xr Oo HF{ ilAr a / n/n SA:!02-Gr-E A-519 Gr A-668 CLC & F** Sorinq coil bearings' washers $rrr. cdcrdcdcm ct t d ddc 0cr thlr fc*rcr rer prdonnrd ln rcccdcocr wllh: AS.n"a, $cnoil lll .3ulsfctpil NF C0mtOilfl|| 3rt''tOlll! (dob o{ rre7'r'77) and crr on llh c$ BENGEN.PATEN.SON c1o'ptilUlfpx "'plarD"ull H tranrra LACOTTA Aat conEof Ref . rreode Case 1644-6 3llEf ITROEH-PAIIRSOil PIPCSUPPOffi COIP' tct ocltactrtoAtA$trr 5. or 1o otraJ' No. - u t .. 4oo0 ?AlTllo. 4000 P roduc s truc rhs J Prodrct ol W€lded fT/-YPElil Cornrucffn l-wr-FBil tv1r I ffiIU grE llt TAV Irr lllttt.l. rnmtB t :1 P l t P cl or t@t frvp-E-l tTffii-l ttc $ttqTfo ctor aa r''tt ltrrlE?t.irlr lEt-trqr lrt aarrf, r rpc lt.?roi?ED r.Orf in lnchrr lacroorod by octuc! trcvrl dirnenlicor. rg trovol dirnrnrioar rhown r ir for lorr llovr ? llorirnu- dlmrnriqr lor grcuP. qr Rod tsko.ooi , Dldor Pnovld For ' Ulcr App[cailo Onty to ROD D1A. (Rl LOAD. noa S.t*tt--th. totll tv rrt ua z 2rA 8.000 I I .630 l s.700 20.700 27 200 lord rhorrtd 'lacludl rn rddltlon'l l5t for Porrlblc flSllti^tt rhrurdc nrHoarr co*rc 12 lltlr*l*&l.l5ry*rirffi ltlcllrl+AttrSOll Pf PC flcld lord rdJushnt flt). IUP|rOIT (gE)l?' FOR ORDERING INSTRUCTIONS SEE SHEETS I t 10 LOAD CAPACITY DATA SHEET lor ilt CtEAn POWET P[Arr comPoNErf sfAl{DARD SlrP?Orrs CONSTANT SUPPORT HANGER 4 000-A1 4 ffiF! 000-81 tl000-Bla D|ICCTION OF LOADIl.G LOAO RAIING (lbr.) Linear ir-nalvsis ct. l,2,3,tlc TETTAPERATURE OPERATING Le'vel A & NORAAA! t CONDITIONS Level B zo zo 'tt F rtr rT' (') c) rJ -l 3059C 33065 33065 l-{ l-l 387 35 387 35 57 I 0 FAUTTED UPSET -22325 22325 5O | 350* oP' tt @ F fil F rfl 44I AZrS 50250 53700 54000 5J250 53700 naxirirum rated. valueg at minimun total travel tabulated loads shsrgn are gi.ze. Refer to slze selection Table on sheets ;E;;;1";-eictr-"nii i r fO for Load-Tlavel conblnations ' toads shown perurit field load adjustment of uP to t Lst without exceeding allowable stress values ' *Load rating for all conPonents except for temperature effect on sPring .. coil. morrrtolr: 5A-36 ' SA-307 GI-q A-519 Gr 10 A-668 CLC & Fffi Gr 1018** SA-193 Gr 87 sori ne coi 1 beari ngs--t1e5-hg-fs ld Dr\ rn.t\ gtt HO 14 ur HSI C,A o 3rlr 1L- 3c- i1 sop 3lnrr cdculCtocr ct ffi tza r^J2tHtte **Code Case L6,U-6 Control Ref. No. lEtonr+ ArEn3Ctt{ PlPt3UPPCtn conPLOTO CA'ACII' DAIA 3TCt? dorc lor rhh p.oduct rarl ;.rfotild la ccccedcm drh: A.3.tI. 3lcnoil lll - Surstcnora flt @PCtilGtlT Slr?iCttl! (d.r. oa irrrr 7.1.7?) ori crqrf,lo cr:- ct2ae.u t ^ l El iOO tlrC.Olrt Rrodrt ot Wdded Ccffitry FTFF6II r-A , Er attE-' lfr"E st"l lEarrctrylt ti g.ari! f lr-qr rtxllffo 'pa FlEFlr'FltE.l litf efoduqt of Welded Constructien. I : I c n :[lcrirnn &DI dlrcarigr l* go,og. Bl, cl HGR. SIZE |/-fu sr-60 7 t* clrt tzv. t/. eSX_ ROD DIA. LOAD. 'inoc (Rl t0 0 to tX 7 t'{ 60 | tlt tx 2 2\ 2h I t -630 r5-700 20.700 27,200 33..00 s"t*ttoo-thc totri toU rtroold lrcluda ur rddltloael l5l for postuic flrld lord ih;;iirit or thc-ittia-tb; @ g orlr. . .r, l;J iffi;in&;iiifrti-Ie;'i.r.-irril'i-.tq'dt''trtt :h'._d:_yjtg] BINGIil+ATTTSO}I TA rs I r% It tn 1610 I rrao Icads exceeding max specified reguire non-standard rod connectiong. ffultnnt- Tf. l.111!,: PIPE SUPP'OTT GOTP. %l tt- (Aooror.l Lbr. Net I Shoo. --'# l2s0 I 1300 FOR ORDERING INSTRUCTTONS & IO SEE SHEETS e 8-1 8-83 IOAD CAPACITY DATA SHEET lor NUCI."EAR PC'WER PTANT COTiFONCiIT STAI.IOARD SUPPORNS CONSTANT SUPPORT SIZE SELECTION TABLE f tr..drti (!! uarlr o'c'isblr rr rrrr 16' esv .tt" il9 unrrr rglrci tc tcgrotica lrcr rcbl'' i 6;;;;"';i"i +Tq. !-8 Orderinq Instructions : Specify-Part No., TyPe, Load Capacity_Data sheet niv, N6. , Size Designation, l{ark No - Operating Load, Total Travel, Thermal Mvt., and Directicn C to H, Dia. and l4aterial of Supporting Rod (C-S- or H.s. ) . Example: 4000-BL-R/1-9, rYk. RHH-7, O.L. 620*' !{VT .2-L/2 " UP , Rod Dia T . T . 3-J-/ 2" 5/8', C.S, r"? I 7/6/ta ' IENGTN.PATERSON PI PESUPPC'ffi CORP. tolo Grtlctrr oAlA SHln Fildr#c TOAD CAPACITY DATA SHEET lor NUCTEAR POWCN PTANT COTiFONENT STANDATD SUP?ORTS CONSTANT SUPP-ORT S I.ZE SELECT I ON CHART - F.r Tln lc:ll l-l tanolt.ir. l0.t l0'tf.i NOTE: Carrrcrt SsPeorrl rhcold br rllocted ritt rgffi. cnr-t?avd lc ingrc cn odrqrrrr lrcvd lrrrrrr tfisr providiq tor ony porribb Giaatt dircrgctcy betrrr rhoc' reiiccl qrd ccruol pipial moYata'lr. <,rL Pt.t -a ,.Ar llCllt $om : ordering Instructions Capacity _Data Sheet iil;i;y'eii[ -No. , tttpe , LoadMark Operati+g nlV. N6., Slze Desiination, Mvt. No. Dj'rection and I il;a,- Total Travel, Thermalof Supporting Roq (C.S. E-t"'ff, Dia. and, llaterial or H.S.). Example; 4OO0-BL-R/1-9, !4k. RHH-7 r O.L. 620* ' t.T. 3-I/2", !{\t\t.2-L/2" UP, Rod Dia' 5/8u C . S. SEnGE'|+ATEnSON PIPCSUPPTORT CORP. tolD cltActll ortA 3Httr frtli TOAD CAPACITY DATA SHEET NUCTEAR POWER PLANT COTAPONENT STANDARD SUPPOTTS TC-4 CONNECTION ++ ! DTR ECTION OF ro ADING DE5IGNED gy. Linear AnalYsis LO,{D RATING (lbs.) ct. l. 2, 3, & MC 350 TEMPERATURE op OPERATINGCONDITIONS LEVEL o€stcN 'l ..'l t'.1'.i'.r L CONDITION 'i lt) 5 6 755 1520 5480 11760 755 t5 20 5480 11760 240 00 57 2AO 75000 87500 7 I A& B NORMAL & UPSET C LEVEL EMERGENCY FAULTED LEVEL 1000 l4 l0 210 0 3040 D 8500 155 00 2210 24 000 32000 572 75000 87500 7 4sI20 I07530 14I000 62A0 100000 115 500 0 154500 Slrur coiculctlom or lorl ddo lor thh product wrc potiorrned ln cccordonct wilh: As-S-E- SECTIOX lll - SUtlSECTlOll Hf {dorr ol .A '/1. \ z3z HAROLD I:OF.TEN JR. { fr.o oD r\ HI cn .;N Hl oi cl O Fi Nc. i36 oLZ uz'. lnt'- = l7 t ,4. ,v{ 9-\ l",rtr4 .svs '.-\ S ..\\IKT. --- LAcoHta ^t€frhaAttsxtnL oJ2a5 Ccnt=ol Ref. No. 11{A 1il1 to L \--rf J lruo 7.1---l I rcr{@ | rtnceN-PATEnsox PlPEsuPPoRr coRP.l rolD c^r?lclTv Drtl 3Hrrt I SHCET rorl (/ s 4004 PAm xo. 4004 ! -|l-i A I 4-C+D T? f I I --r I I I I +l) B v -T F I l- L-s-I{OLE r-H.LE J H SIZEI HANGER SIZE A 1 lcsH l-ToT 4+ 2 1 CSH 8 rol2 5 trl 3 I CSH L3 ro28 r2 4 lCSH29 ro 36i 7 5 I csH 37 ro45i loi 6 jcsH 47 rosotrz+ 7 I (,SH 6C ro54 14+ 8 | csH 55 ro58 L5+ F HOLE HOLE T 2i 2L n n B C D 2 1 )L_ "2 T 2 1 3 T T 3 3 T 8- 16 1l 3 1+ 29 3 T 29 n T 4 Li 4 1i IL32 rl )z 3+ 5 2+ o2 or 5 5 j+ o3 c4 5 8 5 I I 3 I I ONDERING INSTP.UCTIONS S B o3 OT 2T 3 ,3_ o ,q 1u" 3 2L 3 G 1 3 .It- l-32 T 3 I T T 5 -L32 1+ L 16- ^L7 L32 1r L32 * 8- !32 2 z ,L7 t- fiiJ ll n25 )4 .' ') ') -)/- z3 )T 11 .E LJ L32 .9 L32 3 I I lc !-g : Specify Part }lo., Load CaPacitY Data Sheet Revrsron No. r Size DesignationPart 4004 R/ 2-4 Example: PART 4OO BERGEN-PATERSON PIPE SUPPORT CORP. 4 DATE s / 3/ s4 ano F n !t-xf 6 LOAD CAPACITY DATA SHEET for NUCTEAR POWER PLANT COMPONENT STANDARD SUPPORTS TC-7 CONNECT I ON DIRECTION OF I LOADING DESIGNED BY: Linear Analvsis LOAD R6TING_(lbs.') cl. 1.2.3.&MC 350 TEMPERATURE oF CONDITIONS OPERATING LEVEL C LEVEL A & B LEVEL D DESIGN NORMAT 8 UPSET CONDITION 1620 5480 6480 1175 0 1r750 4'24ooolz4oooi32ooo'45120 200 750 875 5720A 75000 87500 37 EMERGENCY FAUTTED 210 0 3040 i218 22!0 8600 15500 7 0 0 107530 6200 i41000 154500 56 t-. r-. I ca I I c-'l I & Bar 5A-36 .i!;ntiz ,; \ -- ,/ 1m =. r-l =,^ i-; fn 9r ./ (N C-r =: | ; Strerr cqlculoiionr or lert dato for ihlr product wcrc pcrlormcd in sccordonce wilh: A.S.M.E. SECTION m . SUESECnON NF COAAPONENT SUPPORTS (dorc ond ore on t-er: i,l l ,- ri., jF: fr= sEAt i?-?3'i6 itEl | ';' 7't'i7) - L4J gJ BERGEA-PA.TERSAN fr rl LACOPta P IP E S U Ne roAD cAPActrY DATA SHEET PPORf C-ON Re PORA| OH ' wHaJaSHtnt I Control. BERGEN.PATERSON PIPESUPPORT CORP. siorreo of isruc lile ot: f. OtZttE U . 40A7 No sHEEr I RF^v' I I l- oF I Al S A- renr Ho. 4oo7 rz1 lrr = i I I ! ' HANGER SIZE 11 2 3 4 H.HOLI A SIZE 112 7 13 28 29 36 4 37 116 I sl r+7 60 ; 61 64 is? i sl *DO NoT usE oN csv - T J 6' T 3l 16 3 I T T 29 1+ 3 S 2L T q 3 1? L32 (r )2 ,r L2 t#l r q ; t2 10 -)L z$l z 7 s* c25l L32 | tt- g 65 I I 4 t, - H HOLE 3 ? 3 5 D B T T ,w fe 5 J 6!) 1 5 58 ORDERING INSTRUCTIONS: specify Part No. , Load capacity Data sheet 3ev. No,, and S:-ze Designation. Part 4007 9.i 2'4 Example: BERGEN.PATERSON PIPE SUPPORT CORP. I eanr 4oo7 loare s/:/st LOAD CAPACITY DATA SHEET lor NUCLEAR POWER PTANT COMPONENT STANDARD SUPPORTS CONSTATIT SUPPOI?T HA|\IG ER 6l I-,n"d t=E ii' 4I0O-LBI 4I00-LBla DIRECTION of LOAOING DESIGNED BY: Linear AnaL',zs'i s LOAO RATING (lbs-) cl. r. 2. 3. 8 Mc TEMpERATURE OPERATINGCONDITIONS Level Levei A & 3 NORMAI. & UPSET srzE C i EM€RGENCY i l-090 350* op Leve'l D FAULTED NOT ;\PPLICABLE * :naxi.:num rated vai-ues at ninirer:::l total i.ravel Refer to Size Selection Tabie on Sbeets u!:it si=e. offer:c :cr each g&9 :or Lcad-T=3"el ccnbj.nalicns. loai,s s ho'*6 per#.t ilei.d load ac.y: us-;nent oi sp to + t5* 'tithout exceeding altowable str3ss l'a1';es. iLoaC 33t:::g f or aJ,1 ccmi:cnents esce9t f o iernPera--u:e ei:ect on s!:rr ng ':abulated. ioads shown are . Ln L ccr-1 - 1J i IlI> Moteriok: 5A-36, 5A-307 A-519 Gr 10i8 Chl** i A-668 CLC & F** ,4.-1:8 Gr lo!.8** i ri ncs exesi.'lt ilF , 2!2! **Ccde Case 1644-6 G,- o. lort dcto for fill prorirrct won grr{omrrd in occordcncr wiit: AsJ,r.a SECnON m . SUgSEg;rOll ilF COmFOilEilt SLr?PCtt.llt (dcl. of irrre 7.f.77) Slrrr colcrrlatlor gnd crronfile sl: ij: r- U]rHI (n ri ijl N 3 t'4gr,ll'il,l sEAr. I L-q'11 iBERGEN+ATERSON PTPESUPPIORT CORP-| scilto itoAocAPAclr?DArlsHEt?lIorv." ., *'t" t-/; rls r;1iF .B J,ffi tAxE<lrT _j; I ffi 5Y- *Same as coxN Ecr oN LBl except top tus rotated. e0 desree.q-,. tt"g**[ffi"d Product of Welded Construction ,ld bc increoscd bY ocruol trovcl dimen3ion.Turnb.cklc ond bolr not iurnished with rhcsc gnits; connccling rod lo bc furnishcd wirh lull ond holf nut lor 5Y'Contccr,ott- NS in LAI & LBI f Mor. dirncarioa lor R lnc 9roup. D t/ta ficld load adiusuent rn roditional 15! for oo3sible Selec:ion-the ictal loed shosid ineludc ror t:/pelAl qnlr:--. iii ii"-r"isht of thc uait q.x.'.nriro lenqttr (Ai'i :hretds nrtional coarse J2 frt). -Roo rhr:ro Requirem"nts'iZ; Dimensions Provided For User APPlication OntY FOR ORDEF.ING INSTRUCTIONS SEESHEETSB&9 BERGEN.PATERSON PIPE SUPFORT CORP. PARr 4tOO DATE 8-1e-83 LOAO CAPACITY DATA SHEET for NUCLE.AR POWER PTANT COMPONENT STANDARD SUPPORTS CONSTANT SUPPORT n 410 DESIGNED BY: o_r.Ar HAN GE R o DIRECTION OF i lB B:lBi" (lbs.) U?AD RATING Linear AnaI'rs!s ct. 1.2,3.&MC OPERATING Levei A & I DESIGN NORMAT CONDITICN lqln LOADING I UPSET IEMpERATURE 350*oe CONDITIONS Levei Level C EMERGENCY D FAULTED 18 L0 I 2 _' 7 ! -; I 3400 c 't -c-l i/ i I i cC' ,c\ I L a) I ! ,I I ! 4950 23 I i- l l ?'1 -.- :l i': -1 t I zt ,s shorrtn are naximr:$ rated vai-ues at !::i :riaricl lctal trave l offeraci io! eacn unii size. Refer to size selecticn Table on sheets I & 9 for Load-T:a"'el combinatlous Load€ shor,{n permit f ielC loa<i ad justment o l- uo to + 15 a wi--hout exceeding allowable stress values. Tabulatei, ioads all- components except iot temperature eii3C-r- oI1 sprir.g *Loai, rating cci'l . ilvlolrriob: SA-35. SA,-3Cj 3rBi t w 'J: t-- 'n r\ ;,1 -668 qLC, t,.f** ffi8** S/ZZ srcucD SA-193 Gr B7 , (sorino coii beann(rs, ffiqs e.te:not i'lF, 2\2i i A.s-U.E. SECTION ilr - SUSSECnON Nf COr,l?Of{CnT SUP?Of,f:S (dctr of iruo 7.1cnd orc on file ot: ?7) i 1 sEAr. ? / i calculntion! or lrrt doro {or rhir pro<iucr wero periomrrd in occotdcncr wilh: Stlrr fidA- I washet"s BEEGEN-PATERSON AzeauaFoe, Contrcl cot^ntltox .100t 3.e=. t"t8ERGEN-PATERSON PIPESUPPORT CORP.I i 2 lolo GAPAC'IY DAIA SH:EI o, .9 i i {,is rifF l-Mr l+l _T 'ri, Eo lll€-qJY ffi I A tr^L..-= .'H + fr rq'ii S * Sarne as LBI except toP lug rotated 9 Y - coHN ECTI oN 0 declrees Product of Welded Construction. . Product of Welded Comtrustion ffio".l(cotarohol|;foruptrovcl,dimcnrion:rhornrhogldbcincrcorcdbyocruollrovcldimenrion. tTurnbuckle ond boir not furnichcd with thcrc unitr; connccling rod to be furnirhcd wirh full cnd holf nur for SY.Connccraon. in LAI & LBI lnche t Mor. dimcnrion f or group. l6 l3 ttla Rod ROD DIAMETER (R) 21 -21 17.20 TR) It/,-tlV.tz l -{2-3 TR) tat r"i-{2 -(2%-4 TR) r,i-{l7rtz rR} Dimensions Provided For 25-28 I User Application Onty z-{2-31i rR) -(l-o7r tR) r 'l-lt-t2 TR) total lo.d should include an addit'lonel l5t for possible field load edjustmnt ieight ot the unit for typerAl only. Selection-thc and the Thread Reguireoents-12.'R.H. thread length (A]l threads national coarse rZ fit). FOR ORDER I NG SEE SHEETS BERGEN.PATERSON PIPE SUPPORT CORP. 8 I NSTRUCT I ONS &9 PART 4IOO DATE R-1R-R.r LOAD CAPACITY DATA SHEET for NUCLEAR POWER PTANT COMPONENT STANDARD SUPPORTS CONSTANT SUPPORT HANGER n G [-]f -l-....1_.{ t_l 410 0-I"A t 100-LBl 0-LBIa 4 410 DIRECTION OF LOADING DESIGNED 8Y: i, ine a r Ana '1. '.zS is @ ct. l, 2, 3, & Mc OPERATING Levei A & B OESIGN NORMAL & UPSET CONDITION SIZE 6E 3t 32 ?? 350* CONDITIONS Levei Level C oP D FAUTTED EiAERGENCY > > 45 7545 8650 7645 8550 9480 10515 30 TEJVIpERATURE I r.l F; I I 94 i- - r0515 i H - Tabuf,ated loads shown are maxi:rum rated values at iiininum total travei for each unit size. Refer to Size Selecticn TabLe on sheets "fi"""a gg9 icr ioaci-T:avel combj'nations ' Loads shown ;enit f iei-d Load adjustlen: oi up to + 153 eithout esceeding allowabie stress values . *Load rati-ng icr ali ccnponents excEpt for temperatrire ei:ect on sPrlngf coii - I Matrrislr: S}.- -16 , -cA- A-5i9 Gr i'li3 C:'l** i A-559 ctc ! F** tA-108 Gr lflS** i in F-r r\ I o r<t p.e I sEAr tC/t4h7 srcnEo beerli A.SJrr.E- SECflON lll - SUSSECltOttl xF COTIPONCNT SUPPOf,nS (dcre oi krue qad srr on 7.1.7? lib ot: EERGEN-?ATERSON ,DEsurFntcorrn ron e:cenrct lF, 2L2L\ **Ccde Case 1644-5 lContrcl P.er. No. sHEgf I ^:i I ggncgN+ATERSoN PIPESUPPoET coRP2"'i sHCEI DATA toro cAPActrY I ffi r\ U-i h-. SA-19 3 Gr (s3r:-rls ecil Slrar colcslstlonr or ttrt dcto lor thlr product woc prr{ornrrd in occotdorrcr wiltr: Lori-l - 4000 PAIT NO. di00 ) ,i 'll .;:t ' r ?F{ *- -a h.o Z- ?^rtaltf t{ r'l 5Y- *Same as LBl excePt top lug rotated 90 degrees. Product of Welded Consfrusticn Product of Welded ConstructionLAI & LBI HANGER SIZE i-2,,..i Z 29 to 36 'Rod toke.our rs lor .t coxN Ecrl oN r;___'l,rfu.,, 11S?, rc its lts nq4 tatAlt4 llr tr8% ltSi imcn:ionr rhown shol e increorco by ocruoi lrovcl drmen!rort. t Turnbtrckle ond bolr nor lurnishcd wirh thcse unils; connccling rod to bc furaishcd with lull ond holf nut {or SY-Connccrion. LAI & LBI ROD DIAftTETER (R possible ieiectron-the tatal loro snouid 'inciudc atr addition.a l5Z for cf ihe unit 'cr :yoctJl oniy:.. rA iiitrJa-niquirenents-12" R.H. thra.o lengtn (All !hret63 nttional colrsr f,oo anc :lre weight rield !ord rdjustmnt frtl. Dimensions Provided For User Application OntY FOR ORDERING INSTRUCT IONS SEE SHEETS BERGEN.PATERSON PIPE SUPPORT CORP. B &9 PART 4ICO DATE B-18-83 LOAD C.APACITY DATA SHEET for NUCTEAR POWER PTANT COMPONENT STANDARD SUPPOTTS CONSTANT SUPPORT HANGER 4l0c-LA1 4100-LB1 4100-LB1a DIRECTION OF LOADING DESIGNED 8Y: Linear Anal'zsis Lo@ cl. 1,2,3, &MC ONDITIONS PERATING LEVEL OESIGN LEVEL A&B LEVEL C EiAERGENC/ NORMAL & UPSET coNolTloN ':l<l< D FAUTTED r_3055 13053 14350 15985 350*OF TEMPERATURE I z ry l_4350 15985 r7515 FO Fd 310 21000 19 I o Fi o Fl \t F rH FO H o o I -l {, F EI t -t I i I atr' ninirnun total trave-lTabuiatec loads shown are maxi:nun rateo vaL':es Tabie on Sheecs Sel-ection Size to Refer offereo for each unit size. 8&gforLoao-Travel cornbinaticns + 15t *ithout exceedLoads shown pernit fieiC load adj ustment of u! tc rng allcwable st:ess r,'aJ-ues. *Load r3ti:ig :cr aiJ. ccnFonenEs except for t3srperature eii=ct on spri::g coil. Motrriolrr Sri-35. SA-307 Cr ot l.lt deto lor rhir producr wore prrforrned in qccordoncr wilh: Slrrr colculotlorr 3 !!?r,-'' .€- SECITON il. SUUTECTTON NF COIIPIONENT SUP?Of,nS (dctr o{ lrrre A.Sl snri cre on (J,lc- i,Odill r^ J3 tu Fs..." : HT\ I Uot Hl <o\ 7/77 srGNGO 7-l-ll .l 08 Gl. 1',1 lEli Cr 3; :SA.-i93 lr'BERGEN-PATERSON l ( Scr :no cc'i l , bearings ,washers ' i ri ncs exenDt l,lF-2i21 Conc=ci Ref. No. - 4t-rC0 l**Code Case 1644-6 PAf,I NO. i eenoeN+ATERSoN PIPESUPPoRT coRP. 1100 sHtET oltA .olocAPAClTl | ,A- i HAROTD ,J; {ih ct: ) rls r;irbF J,-ffi TAx€-d.tT o ffi A ITYPE LBr"l * IIYPE LBrl S -_l Y . cOxN EcTI oN Product of Welded Product of Welded Construction. Constnrctbn * Same as LBI except top lug rotated 9 0 degrees . Torl L TRAvEL in LAI & LBI HANGER SIZE DIM. 37 to Jtj 5 4, 3'/f 116!t 16i 9',/r' 9. 8t!r' 22 q/. v' 9'/t 4 'Es a. 3it: 'Eb 9Vr' K f1, 4l Rod toxc-our rs t Tsrnbucklc ond LAI & LBI I{ANGFP (I7F 2l\ ? 22 l0:" ld, A l6 6\ l6 I l5'( l5'4 l5 21'/, 2'l 2l 2l ll ll I 1l loche s 9% 20'i, t0 t014t I I I l4 lt3 r3 t 9'i I9"119 t9 l5 I d": l4 l4 20'i 20 20 I d'.. 1 t?l l3'l r3 t4 12 13 I 2';l't 2 I5 ll l8 I6", 16t./, l9t" r8 t7 l7 17", l8 t8' I I I I 2"il 2", It ctuoi trcvei oimensron 4"" l5 l5 l5 l6 ll l'4 I I a/. I I a iocrcosco by should be iocrcosco i"t oo-" r.oici (cold ro hot); lor up trovai. dimcorronr:hown 3llo bolr nor l,.rrnirhcd wirh tharc uaits; connccting rod to bc furnirhcd wirh full ond holl nur lor SY-Conncction. tA tB c rlvlCFlJl -9.i --u.i Ll F -Tt L TITI N 5f, Wt, (Approx.) Lbs ','1 I W Nei l 5'r 650 {',/. !/" l'/. 25'A aAf. I a'/, 37 - 6. t Mdr- diF...io lr grogt. di6'n'ic'r tTc6ct.r.d dimnri.6 do oor crpl, t6 unir. J!6or.d by (a) ir si.G s.l.dion cho'r F 819. l.stollihs 7',/, I ROD 5ELECTION CXINT ROD DIA. (R) lth rr5 lt/t .'a 'Yoil'llG 5hpo. 680 o' ccalication' ffi 2 '2Y. rs700 I 20.700 I 27.200 r.630 8.000 field load adjustmnt for l5t an Possible addltlonal lnclude Rod Selection-the total load should ino irti-reieht of the unit for typerA.f onlyr(All -fit). {? thrrads national coarse i'ii"io-niiui"enents-tz; R-H- tnriia lensth LOAD. Dimensions Provided For User APPlication OntY FOR ORDERING INSTRUCTIONS SEESHEETSs&9 BERGEN+ATERSON PIPE SUPPORT CORP. PART 4IOO DATE 6'l'r g-g3 LOAD CAPACITY DATA SHEET for NUCTEAR POWER PLANT COMPONENT STANDARD SUPPOTTS CONSTANT SUPPOI?T HANGES. {1 16'l 4100-LAl 4100-LBl 4100-rBIa DIRECTION OF LOADING LOAD RATING (lbs-.) cl. l, 2. 3, & MC DESTGNED By: i:::-ear i.nal'zs i s TEMPERATURE ]-? Le,rel .l 1 -l {8 5C 53 coNotiloN 22325 24290 2520A zELL5 30590 Le,rel B D -- 28lL5 33065 35900 'i- 41400 44100 t .. I An -{.lrUU I FAULTED z, -J4gV 35900 Leve C EftTERGENCY 22325 24290 )G)nn 4L{cc i A,1., NORMAL & UPSET "-OT CONDITIONS OPERATING OESIGN O 4.7 L3 0 >t 58 50253 60 54 C00 30250 3700 54000 jj700 lailuflte<i lcacis siown are maxinum rated values at m:-ni::rl5o total travei offer:i fc= each uni-. size- F.efer to size Sel ect:cn Table on Sheets 6 3,9 icr :oad-T:al'e1 combinations Loads siloH:r per:3d r-- :-ielC load ad justnen;- of up tc + i51 '"/ithou*- exceeiirg alictrable st:ess ',-alues. rload rai:::g for all com-Ecnents exceP+- ior '.emperature eiiect on sprinE coiL. Stnr caiculctionr or t.d doto for thir prcdu<f wccr por{orrnrd in cccordomr with: A.Slr.E SECnON m. SUE36CnON Nf COlllPOt{€llT SUPPOT$ (dcrr ot ixtuo 7.1cnd orooa lilo cr: 1-5:9 3r i018 C't** i , SA-133 Cr" 87 (scrino coil 3 r\ U:I cn i rn li l.- 1CE r:r ) f** :{r i n1 Q*:f, at Sle'.{F bear':ngs, r )lF. 2\21 rina **Cooe Case I tlf'-6 1.'as EEEGEN-PATERSON Iers.i i &lcor i ,t?csazFottawtntnod t4 ttcr,la(ttutac.0traa.4 s I Consrol CORP. BERGEN.PATERSON PIPESUPPORT gHCfT IOAO CAPACITI DAIA li) - ^ 4000 PATI HO. 4100 B / iL sil I ,,'fioA ri rls rJFF ,lr .5\r .?Y1 rffi llxe{r? I ; rll I --6- ;o---r- ffi "-, Same as LB1 l^Ielded '*" I lt 5 Y - CONN Product of -a TAx€ -OrJT rAxE-qrr Eo * Lo * l. Eb ECTI ON except toP 1ug rotated 90 degrees. Produst of weHed Comtntcdott Construction. LAI & LB 22',/,122 I I '/,'129 |.29 21 l'22 l2l:, l2l 27 128 .|20",120.,\ 126"\ 20 il9'."119 llSi; 26 126 125';125 124"\121 od tokc-oul is lor down rrovel (cold to hot); lot up ?rovcl, dimenrionr sho*n rhosld bc increosed by ocruol irovel dttn.naroo. 'Turnbucklc ond bolt nor furnirhcd with thcsc unilr: connccting rod to bc futnished with full ond holl nur for SY-Conncction. LAI & LBI ll&:_- dimcnrion lor group. ROD SELECTION cH A R_l lY. RoD DtA. (R) I tlr LOAD- I 11.630 ls700 17 to 6A 2 I zo.zoo I ) 2V ztt zz,zoo :t3 d00 Selection-the total load should lnclude an additional 15t for possible and the reight of the unit for typeul only. Thread Requirennnts-le' R.H. rhread length (All threads national coarse l2 Rod field Loads exceeoing load adjustment fit). nn'ax specifj-ed require non-standard rod conlrections. Dimensions hovided For User Application OntY FOR ORDER I I.IG I I'ISTRUCTI SEESHEETSB&9 BERGEN.PATERSON PIPE SUPPORT CORP. PART 4ICO DATE 8-i 8-83 ON F!{n 6t.xFa LOAD CAPACITY DATA SHEST for NUCLEAR POWER PTANT COMPONENT STANDARD SUPPOffiS S I ZE SELECT I .t.r-r - rtlXll Utr RATE lood lor tt'. ol!!!4i!!-!.!s-3.4 4r', I-| 5ti FOR SIZES I THRU 7 SEE PAGE I'. CONSTANT SUPPORT {Tho aiaiova tooo rr rh. 605 773 | I 13sl 38ol s20 I {55 I 505 505 J35 .r05 los-l- ,rs t 2is srot 540 18 -T I I 1655 I l4l5 2.t.t5 I 20{5 272OT- 7255 I -1060 ll4 1335 i- ledo I 1670 r- ees I t230 r36s I eoo I lslg I 3600 I 1000 :4001 {320r I I 5l85 I r :05 I 135 I { 500 r 560 99J I | leo 230 il 15 I 1020 I 1175t I 1070 i2701 i385 r i ll80l 1285 1. I r2C0 r 15,15 1700 I l{40 1855 I 1730 I :sosI 3{:sl:ttoi 2a5s | ?435 I ?1r5 I 75 I 3190 raro r 1330 I 3e35 i j!q0l--:-l-l-q-L--j!.!gl :235 l2lr0 I I le65l 1525 1665 I l60r 19801 ls30l I 2160 | 1995 i }!le 2e70J I {65 l_fgoI 2575 t rrgs | 2t5 I t60l 3 se{o-T- 17s5T 3960 | 2801 2601 2151 :010 t22S t650 I 23s I al5l | lll0 I I i 30sl 3651 r30l I-oso-T 1605 ON TABLE IT-i" 1100 I ll 16 I 7215 | 6l 9640 I ?t 11 J. I n -i i i il7oorl d5l r ll760rt : 8265 7EI'6-T- zoSS 10060 :l3055rlll80l i 5260t !7aO I r aars o-ZE-T--T3E5-T--d725 {t I s8so | I 7ee5 !610 i r{10 )430 | 60301 I 737st 5040 jllsl t :600 51701 .t8e5 6ry91-__9 tlgll0^ll ' i 2r700^l icosoel 16925 r 70rl st---l---- i s70ot 783ti-71201 65301 9790 trs3t 11301 iaast i : I r:gt ts i lJo l3390lt2l70tlll60 mi5-T-mEs fll825 I 6295 I 14815 18100 ffi I 17 195 I '.14990 10910 I l0l3s I e{50 I EE6o l5 19.25 i -i I r 3 zro ! _]_2_Dl_i_11!t9_illl d9a5 I 2 ?rir75 2al9o t2960 | llgto I 13100 I I i :edoo I J5,{50 I r1550 I Conrtont SuPPocrr :hogid bc rciccted wirh :uifi' cicnt ovcr.trovci lo ingulr on I i6320 | :8910 I 176.O t9l 15 | iExo-T-:rooo NOT E: 13870 i i7{t0 : i i la,l.o r llo3o I I ao€ouote trovci rctcrvs thul 2?r!5 7ro0 ;roviding for ony porribla I zs2oo I 2 I t2710 I :05 I 53300 I re800 I {6t50 oircrcooncy bctwccn thco' rcrrcoi onri octuol piping I rc 'lo, I i':n:::l L]3 rt'r: :vorrtora'" lor c3/ onq ii3 s..t ;ubta€r to ,crlcllon t i.cqrroat rlaf, tttr?3. Oraering Inst:uctions : Specriy- Par+- Nc - , TYPe, Loai ,:apaci:: Data Sheec ?.ev. No. , S j-ze Desig:racion, )la.r:< )lo. Cperatiagr Load., Tctal Travel, thermal i'!vt . , anc Direct i.cn C to ,': , Dia. ano Material of S uppor=ing Rocr (C.S. or li.S.) IxannnLe: .i10C-LBl-R/1 -9, l1k- PJIS-7, O'L' 5201r, T.T. 3-L/2", l'Ivt .2-L/2" ii?, P.od Dia. 5/8" SEAI q /t/tt C.S- i BERGEN-PATERSON PI PESUPPORT CORP. SIGI{ED LOAO CAPACTTY OATA SI{TCI i srssr I ^::' * o, 9 ! 'oj PARTHO. d100 tlrn C?.IFI LOAD CAPACITY DATA SHEET for NUCLEAR POWER PTANT COMPONENT STANDARD SUPPOffiS SIZE SELECTION TABLE CONSTANT SUPPOP.T r.., - gr, ftt. t"t! i*.--.---,." I I f' lo rTol 160l lsot f"oa to"q. t"t.,.. li ron EAcl{ 5lz€ ! NOTE: Conrtonl SuPporrr rhould be rcicctcd with luifi' i-3EFi lso i 330,1---flu9l | !36-T--i6-l-Toi l5Er {3oi 3eo IOSO ;j65 :{30 I | t9t0 I provrriing [or cny Porriblr di:crcocnqT bct*ccn rheo' :75 rcricol onci octuoi rlo 720 t 6t5 1035 i ?e0 I I I I 10401 lll0l I 1040 1200t llr0 r3'i0!!??0 lll40 ll lt ld90 I i8 I 2020! 13751 ,i ' "r ---lt-. :l.i.l cua> Piping movGmca?- r5 I il90 I I cient over.trovcl to in:urc on odrquota trovcl relcrve t{rul l{15 | 970 l 1750 'l I I 12551 :seot:ltol 301 45!5 I . : I r.55 I irc65 I rrrio i r36Jo | 1870 12935 i I r u2r Ll 35. | , ;.ras I 3a6o I I !! ri:roir3.r3ot tq | 54 a99o in"66o t tot9s t 9620 1 3710 l 3160 r 12525 1 11525 | l! l?C20 ffifor ltgtoI t5o!5rltr25 lr tsgrot 180051 l7lr0l iTlB.rol-2oteo t0185 tolrr970lll050r! 16160|15500Il{790|l{ iiii ao65 .t I 7 ?{ ffiiLotu_l__:l!9_l5l tJsr0 t t3t8o I 12580 I llTr I I | 6550 I lee?t I 17900 ieo6o r I 16520 l7 ; i5310 20650 i- rrooTl?{co I 37300 l 3:600 61a001583001553t0 I *rlr> ! 1==- / ls. I lr Oree::-:lg Inst,=uctj-cns : Par-- )Io - , T!'Pe , Load Capacat:'Dat,a Sheet Spec \:l Re-r. )lo.r Size Desigracj-on, Mark -\..o. Ogeracing Loai, 'Total T=a';el, lhennal M'/t. , and, Direction C to J, Dia. aio Material of Supgortlag F.cC (C.S. or I{.S.) - SxampIe: ,1100-LBI-R'i 1-9, :'Ik. R-HH-?, O.L ' 520i ' T.T. 3-L/2",Ilvt.2-L/2" UP, Rod Dj-a. - 5/8" a /.t/-- C.S BERG EN.P AT.ERS.OTTI PI P€5 YTSO RT CO RP. ! SHEET 9 --3 PATT ilO. ;! I i1,n CERTIFIED DESIGN REPORT SUMMARY rH; H lor NUCLEAR POWER PLANT STANDARD SUPPORTS MACHINE THREAD ROD Hd DIRECTION OF LOADING Temperature:ff Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) For higher temperatures in the Test Condition use Level B loads the maximum temperature is 100 f. up to the temperature shown for the Operating Condition. v 7 q, DESIGN SPEC NO.: DESIGN REPORT NO.: DS-5000 R0 DR-5000 R0 Rated Loads (lbs) for Classes 1,2,3 & MC REV OPERATING CONDITIONS Design Size Condition Level B Level C 810 1500 140 810 1695 2120 1500 2715 4065 3400 s090 9320 15040 21860 29510 38910 51130 62980 2400 3600 5600 3/8 610 610 1t2 1130 1810 1130 1810 2710 4960 8000 2710 4960 8000 5t8 314 1 1-1t4 1-1t2 1-3t4 2 2-1t4 2-1t2 1 1630 15700 20700 27200 33500 Test Condition (see Note) Level D Level A 1 1630 15700 20700 27200 33500 24/J,O 3500 6600 10600 15500 20900 27600 36200 44600 915 744o 12000 17445 23550 31050 40800 50250 1 10600 15500 20900 27600 36200 44600 NOTE: SA- 307 Gr. B hex nuts may be used as a part of this component standard support at the above load ratings. lc"^"Yry equirements of the applicable Code. I Materials; to o Rod: 54-36 o) The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: ul :) o a Bergen Power Pipe Supports, lnc. J Product Englneering Deparlment z (, ro REV ]ONTROL REF Certitication BERcEN-powER ptpE NO. s.tppo?rs, rNc.I i:Tl I K 5OOO PART NO, 5000 MACHINE THREAD ROD ROD SIZE THREAD A s \sf STD. THREAD LENGTH T{ T2 3t8 3/8 16 UNC -2A 6 6 1t2 1t2 13 UNC -2Al 6 6 5/8 5/8 11 UNC - 2A 6 6 314 3t4 - 10 UNC -2Al 6 6 1 1 8 UNC.2A 6 6 { REV 1-114 1-114 - 7 UNC -2A 6 6 1-1t2 1-1t2 - 6 UNC -2A 6 6 1-314 1-314 -s UNC -2A_ 12 12 4-112 UNC - 2A 12 12 - 4-112 UNC - 2A 12 12 12 12 2 2-114 2-112 22-1t4 2-1t2 -4 UNC -2A NOTES: All dimensions are in inches. 2. Dimensions are provided for user application only. 3. Part No. 5000 as shown. (right hand threads, both ends) 4. Part No. 5001 with special thread. (right and/or left hand threads) 5. Quantity of hex nuts must be specified if required. 1. o o o, l! f a U) J z o e o <" G IEV nns H Orderinq lnstructions: Specify part No., CDRS revision No., and size designation. Example: Part 5000 - FU0.1" x 3' ' 8" Lg. BERGEN-POWER PIPE SUPPORTS Hd CDRS CATALOG INFORMATION SHEET PART DATE 5OOO 91112007 ffi CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS EONTINUOUS THREAD ROD E DIRECTION OF LOADING Temperature: NOte: @iE The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. (', 7 7 (a) { DESIGN SPEC NO.: DESIGN REPORT NO.: REV Size Design Condition 610 1130 1810 2710 4960 8000 11630 15700 20700 27200 33500 3/8 1t2 5/8 314 1 1-1t4 1-112 1-3t4 2 2-1t4 2-1t2 DS-5000 R0 DR-5000 R0 cl Rated Loads (lbs) lor Classes ,2,3 & MC OPERATING CONDITIONS Level A 610 Level B Level C 810 1130 1810 1500 915 1695 24AO 2715 2710 4960 8000 3600 6600 10600 15500 20900 27600 36200 44600 4065 1630 15700 1 20700 27200 33500 744fJ/ 12000 17445 23550 31050 40800 50250 Test Condition (see Note) Level D 1 810 140 1500 2120 3400 5090 9320 15040 21860 29510 38910 51130 62980 2400 3600 6600 10600 15500 20900 27600 36200 44600 NOTE: sA- 307 Gr. B hex nuts may be used as a part of this component standard support at the above load ratings. I Cenrry Inrs uuFtD 'equirements of the applicable Code. I "ornp@ r\ o o o, Materials: The Design Report & Design Specilication Rod: 5A-36 are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: uJ f a a Bergen Power Pipe Supports,lnc. J Producl Englneering DePartment o = 3ONTROLREFNO. E o REV Certification BERGEN-POWER PIPE SUPPONTS, INC. Sheet lof REV. 5006 PAtt I NU. 5006 1 ^\ CONTINUOUS THREAD ROD A l-_ r L L ROD SIZE THREAD A {t rI/4" MIN. MAX. 3/8 3/8 16 UNC -2A_ 6 6'-0" 112 112 13 UNC -2A- 6 6'-0" 5/8 5/8 11 UNC - 2A 6 6"0" 3t4 3t4 10 UNC -2A- 6 6'-0" 6 6',-0" sl - 8 UNC -2A 1 1 1-114 1-1t4 - 7 UNC -2A- 6 6',-0" 1-112 1-112 - 6 UNC -2A- 6 6'-0" 1-314 1-314 - 5 UNC -24 12 6"0" -2A 12 6'-01' - 4-112 UNC - 2A 12 6'-0" - 4 UNC -2A. 12 6''0" REV 2 2-114 2-112 22-1t4 4-112 UNC 2-112 NOTES: All dimensions are in inches. 2. Dimensions are provided for user application only. 3. Longer lengths availablre, if required , on special order. 1. F- o o o, lrJ f U) 9, J z G o e. o G Orderinq lnstructions : Specify part No., CDRS revision No., and size designation. Example: Part 5006 - R/0-1" x 3' ' 8" Lg. REV ffi H BERGEN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART DATE 5006 91112007 tit J. CERTIFIED DESIGN REPORT SUMMARY for ri E NUCLEAR POWER PLANT STANDARD SUPPORTS FORGED SIEET TURNBUCKLE. PART NUMBER 51OO DIRECNON OF LOADING t Nott' Design Spec. No. DS-5100 Design Report No. DR-5100 For, the test condition (Hydro) the maximum temperature is 1000F. For higher shown for Size Design Condition 3'8 $e Operating Condition. Test Condition OperatinE Conditions Level A Level B Level C Level D 730 730 971 1,095 1,460 971 112 1,350 1,350 1,796 2,Azs 2,700 1,796 5'8 2,130 2,130 2.833 3,195 4,260 2,833 3t4 3,230 3,230 4.296 4,845 6,460 4,296 lsee Note) 1 5,900 5,900 7,847 8,850 11,800 7,947 1114 9,500 9,500 12,635 14,250 19,000 12,635 11t2 13,800 13,800 18,354 20,700 27,600 18,354 13//4 18,600 18,600 24,738 27,900 37,200 24,738 2 24,600 24,600 32,718 36,900 49,200 32,718 21t4 21t2 32,300 32,300 42,959 48,450 64,600 42,959 39,800 52,934 59,700 79,600 52,934 39,800 loads (lbs) for C/asses 1,2,3 &MC CONTROLREFNO. fie requirements ol the applicatk code 3500F temperatures in the Test Condition, use Level B loads up to the temperature Rated I cerlify this CDRS complies with Temperature: MATERIALS Forqino: ASTM 4-668 CI-ASS C/D (CC N-249) Bolts: N/A Nuts: N/A Pin: N/A Studs: N/A Exempt N/A 51()() The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Bergen Power Pipe Supports,lnc. Product Engineering Department REVISIONS /i Oriqinal lssue 1 0/27109 /t /t\ sEpJ- Va/zzhf lslGNED /z\ BERGEN POWER PIPE SUPPORTS, INC. /i SHEET 1 OF 1 REv. a PARTNO. 51(l(} litJ, CDRS CATALOG INFORMATION SHEET al FORGED STEET TURNBUCKLE. PART NUMBER'I0,O ROD T S DIAMTER 3t8 71t8 9t16 1t2 7 1t2 7 7t8 15/16 81t4 11t8 5/8 3t4 3t4 1 I 1 1t4 I 1 I3t4 17 t8 1314 10112 2 111t2 21t4 23t4 21t4 12314 3 3/8 21t2 131t2 33t4 112 1112 1 1/8 9t16 1.)Alldimensions are in inches. . 2.) Dimensions are provided for user application only. 3.) One end is right hand tap, one end is left hand tap' ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Rod Size. DGMPLE: 5100-R/0-3/4" REVISIONS /0\ Oriqinal lssue 10/27109 /3' 'l /A /2\ /s' BERGEN POWER PIPE SUPPARTS, NC. SHEET 1 OF 1 REV. A PART NO. 51OO CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS FORGED SIEET CTEYIS . PART NUMBER 5110 DIRECTION OF LOADII{G I I i Note: Design Spec. No. D95110 Design Report No. pR-lfllll 3500F For the test condition (Hydro)the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Rated Loads I certify this CDRS complies with Temperature: 1,2,3 &MC $e requirements of the applicable code ASTM A-668 CLASS C/D (CC The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Bergen Power Pipe Supports, lnc. Retainers NF-2121 Product Engineering Department lssue 10/27109 BERGEV POWERPIPE SUPPORTS, INC, PART NO. 5110 lir ft CDRS CATALOG INFORMATION SHEET :J I . FORGED STEET CLEY'S PART NUMBER 5110 raoFt-t.) I 1 Grip Equals Thickness of Plate Plus/t" ,-- Grip TAP stzE E 1 5/8 1 5/8 1 3112 31t2 4 21t2 5 3 1112 1 5/16 3112 I 1 114 PIN F 1t2 1 5/16 1 5t16 1 5t16 5/8 1 11t8 BLANK slzE GRIP 1t2 2 1t2 5/8 2 5/8 5/8 3t4 2 7t8 21t2 3t4 1t2 11t8 3 7t8 5/16 111/4 5 3 1 1t2 1 5t16 1t2 1 3/8 3 1 1112 6 31t2 1314 1518 1t2 1 5/8 31t2 1t2 17t8 21t4 21t2 23t4 4 6 11t4 11t4 11t2 11t2 6 1314 13//4 6 4 2 2 7 5 2112 13t4 21t4 5i8 21t4 I 6 e rJ 2314 3t4 6 3 23t4 3t4 2112 . D 5/8 3t4 ' c 1 7t16 1 7116 1 7t16 318 NOTES: A I 5 1.)Alldimensions are in inches. 2.) Dimensions are provided for user application only. ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Tap Size' DGMPLE: 5110-R/0-3/4' Part Number 5111is for Left Hand Threads. REVISIONS /o\ Oriqinal lssue A ./ z\ /3\ /4\ /s\ BERGEN POWER PIPE SUPPORIS, INC, SHEET 1 OF I REV. A PART NO. 5110 tit f' CERTIFIED DESIGN REPORT SUMMARY for d b NUCLEAR POWER PLANT STANDARD SUPPORTS FORGED STEET WELDLESS EYE VUT RIGHT HAND . PART NUMBER 5130 ---r-I DIRECTION I OF I LOADING I I i Nott' Design Spec. No. D95130 Design Report No. DR-5130 Temperafure: Fo, the test condition (Hydro)the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Size Design Condition 3'8 730 Level A 730 1t2 1,350 1,350 5'8 2,160 2,160 3t4 3,230 3,230 Test Gondition Operatinq Gonditions Level C Level B (see Note) Level D 971 1,095 1,460 971 1,796 2,025 2,700 1,796 2,873 3,240 4,320 2,873 4,296 4,845 6,460 4,296 5,900 5,900 7,847 8,850 11,800 7,847 11Il4 9,500 9,500 12,635 14,250 19,000 12,635 11t2 13,800 13,800 18,354 20,700 27,600 18,354 13t4 18,600 18,600 24,738 27,900 37,200 24,738 2 24,600 24,600 32,718 36,900 49,200 32,718 32,300 32,300 42,959 48,450 64,600 42,959 79,600 59,700 52,934 39.800 Rafed Loads (lbs) for C/asses 1,2,3 & MC 52,934 1 2114 2112 39,800 CONTROLREFNO. lcertify this CDRS oomplies with he MATERIALS rcquirements of the applicable code 3500F 'orqinq: ASTM A-668 CLASS C/D (CC N-249) Bolts: N/A Nuts: N/A 5130 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: N/A Bergen Power Pipe Supports, lnc. Studs: N/A Product Engineering Department Exempt N/A REVISIONS ea-hK.C66 *.Al Vo,/zz/a? /o\ Orioinal lssue 10/27109 /) A /a, ISIGNED /z\ BERGEN POWER PIPE SUPPORTS, NC, /i SHEET 1 OF 1 REV. A PARTNO. 5130 ti7 r, CDRS CATALOG INFORMATION SHEET J b FORGED SIEET WELDLESS EYEA'UT RIGHT HAND. PART NUMBER il34 - --l- I I TAP SIZE B c 11t2 11t2 11t2 11t2 1 3116 1t2 2 1 3/8 11t16 1 1 1 3/16 112 2 1 3/8 11116 3/16 112 2 1 3/8 11t16 3/16 2 1 3/8 1 2 111t16 1t2 3t4 11/i4 2112 1 13/16 11//2 21t2 113116 13,4 4 2 4 21t4 4 4 A 3/8 1t2 5/8 3t4 21t2 4 E D G F 11t16 25t8 115t16 1 3 3/8 2318 1 3 3/8 23t8 4 1112 6114 4 4 11t2 11t2 61t4 61t4 61t4 4 11t4 11t4 21t4 21t4 4 2114 4 21t4 4 1112 1 1,) All dimensions are in inches. 2.) Dimensions are provided for user application only' ORDERING INSTRUCTIONS : Specify: Part Number, CDRS Revision Number, and Tap Size' DGMPLE: 5130-Rl0-3/4' REVISIONS /il /t Oriqinal lssue 1 0/27109 /t\ /i\ /s\ BERGEN POWER PIPE SUPPORTS, INC. SHEET 1 0F 1 REV. A PART NO. 5130 tit CERTIFIED DESIGN REPORT SUMMARY for ], d Y NUCLEAR POWER PLANT STANDARD SUPPORTS FARGED SfEEt WELDLESS EyElrUT - PART NUMBER 5131 . Left Hand Tap _f DIRECTION I OF I LOADING I I t Temperature: *ott' Design Spec. No. D95130 Design Report No. DR-5130 Size ,0r' the test condition (Hydro)the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Condition 3'8 Level A 730 Test Condition Operating Gonditions Level C Level B Level D (see Note) 1,460 971 1,796 730 971 1,095 2,025 2,700 3,240 4,320 2,873 4,945 6,460 4,296 1t2 1,350 1,350 1,796 5'8 2,160 2,160 3t4 3,230 3,230 2,873 4,296 1 5,900 5,900 7,847 8,850 11,800 7,847 1114 9,500 9,500 12,635 14,250 19,000 12,635 11//2 13,800 13,800 18,354 20,700 27,600 19,354 13//4 18,600 18,600 24,738 27,900 37,200 24,738 2 24,600 24,600 32,718 36,900 49,200 32,718 2114 2112 32,300 32,300 42,959 48,450 64,600 42,959 39,800 39,800 52.934 59,700 79,600 52,934 Rated Loads I certify {JbsJ for Classes t,2,3 & MC CONTROLREFNO. fris CDRS complies with lhe MATERIALS requirements of the applicabh code 3500F Foiqins: ASTM A-668 CLASS C/D (CC N-249) Bolts: N/A Nuts: N/A 5131 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: N/A Bergen Power Pipe $upports,lnc, Studs: N/A Product Engineering DePartment Exempt N/A REVISIONS At-*/,&.% senl I lslcNED /N I Orioinal lssue 1 0/27109 /t /i BERGETV POWER PIPE SUPPORTS, INC. /3\ /il iJ SHEET 1 0F I REV. A PARTNO. 5131 CDRS CATALOG INFORMATION SHEET FARGED SIEET WELDLESS EyE JUT ' PART NUMBER 5131 ' Left Hand Tap _l_ I I TAP SIZE A B c 318 11t2 1t2 1t2 1t2 F l.t 2 1 3/8 11t16 2 1 3/B 11t16 2 1 3/8 11t16 1t2 2 1 3/8 314 25t8 1 15/16 1 1 D E 112 1 112 5/8 1112 314 11t2 1 3t16 1 3/16 1 3i16 1 3116 1 2 1 11116 1114 21t2 21t2 1 13/16 1 3 3i8 11t2 113116 1 3 3/8 23t8 23t8 13t4 4 4 1112 6114 4 11t2 11t2 11t2 6114 4 6114 4 21t4 21t4 21t4 61t4 4 2114 2 4 4 214 4 4 2112 4 4 11t16 114 1 1t4 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only' ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Tap Size' DGMPLE: 5131-R/0-3/4" REVISIONS ioinallssue 10127109 BERG EN POWER PIPE SUPPORIS, INC. SHEET 1 OF 1 PART NO. 5131 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS FRICTION TYPE ANCHOR DIRECTION OF LOADING LOADIN€ DIA6RAA,I Note: Temperature:650 " F The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: K 7 { DESIGN REPORT NO.: DS-6015 R0 DR-6015 R0 REV FA (LBS) / MA (|N-LBS) Rated Loads (lbs) for Classes 1,2,3 & MC PIPE SIZE OPERATING CONDITIONS Design Test Condition Condition Level A Level B Level C Level D (see Note) 3t8 120/1000 120/1000 160/1333 180/1500 240t2000 160/1333 1t2 200/1600 200/1600 266t2133 300t2400 400t3200 266t2133 3t4 200/1600 200/1 600 266t2333 300t2400 400t3200 266t2333 1 400t3200 400t3200 533/4266 600/4800 800/6400 533t4266 11t4 600/4500 600/4500 800/6000 900/6750 1200/9000 800/6000 11t2 800/5500 800/5500 1066t7333 1200t8250 1600/1 1000 1066fl333 2 1000/7800 1000t7800 1330/10400 1500/11700 2000t15600 1330/10400 lcertify this CDRS complies with the requirements of the applicable Code. t\ o a o) Materials: Plate: 5A-36 Bar: 5A-36 UJ Studs: SA-193 GR 87 a Nuts: SA-194 GR 2H Washers: SA-325 Ty 1 f a J z Itr o REV The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports,lnc. Product Engineering Department CONTROL REF BERGEN.POWEN PIPE SUPPORTS, INC. NO. Sheet lof 3 601 5 A REV. PAHI N(,. 6015 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS FRICTION TYPE ANCHOR DIRECTION OF LOADING LOADINo DIAERA'I,I NOte: 'F The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: rp Temperature: 650 DS-6015 R0 DR-6015 R0 REV FB (LBS) / MA (|N-LBS) Rated Load ls (lbs) for Classes 1,2,3 & MC PIPE SIZE OPERATING CONDITIONS Level C Level B Design Test Condition Level D (see Note) 180/1500 240t2000 160/1333 266t2133 300/2400 400t3200 266t2133 200/1600 266t2333 300/2400 400/3200 266t2333 400/3200 400/3200 533/4266 600/4800 800/6400 533t4266 11t4 600/4800 600/4800 800/6400 900/6750 1200/9600 800/6400 11t2 800/6000 800/6000 1066/8000 1200/9000 2 1000/8000 1000/8000 1330/10666 1500/11700 Gondition Level A 3t8 120/1000 120/1000 160/1333 1t2 200/1600 200/1600 3t4 200/1600 1 1 600/1 1000 1066/8000 1330/10666 2000t16000 I certify this CDRS complies with the requirements ol the applicable Code. Plate: 5A-36 Bar: 5A-36 o, Lu Studs: SA-193 GR 87 Nuts: SA-194 GR 2H f a a J Washers: SA-325 Ty z g tr Bergen Power Pipe SupPorts,lnc. Product Englneerlng DePartment 1 CONTROLREFNO. 6015 o REV The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Materials: io o Certification BEBGEN.POWER PIPE SUPPORTS, INC. Sheet /ot 3 PART NO. /N 6015 CERTIFIED DESIGN REPORT SUMMARY TFA lor NUCLEAR POWER PLANT STANDARD SUPPORTS FRICTION TYPE ANCHOR Nd H DIRECTION OF LOADING Temperature:ff Lq4AtM E49B4r NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: tp DS-6015 R0 DR-6015 R0 REV FC (LBS) / MA (|N-LBS) Rated Loads (lbs) for Classes 1,2,3 & MC PIPE SIZE OPERATING CONDITIONS Level C Level B Design Test Condition Level D (see Note) 180/1500 240t2000 160/1333 266t2133 300/2400 400/3200 266t2133 200/1600 266t2333 300t2400 400/3200 266t2333 400/3200 400t3200 533t4266 600/4800 800/6400 533/4266 11t4 600/4800 600/4800 800/6400 900/6750 1200/9600 800/6400 11t2 800/6000 800/6000 1066/8000 1200/9000 1600/1 1000 1066/8000 2 1000/8000 1000/8000 1330/10666 1500/1 1700 2000t16000 1330/10666 Condition Level A 3t8 120/1000 120/1000 160/1333 1t2 200/1600 200/1600 3t4 200/1600 1 rcenrryInrs uuHD "o.o@ Code. I equirements of the applicable Plate: 5A-36 Bar: 5A-36 Studs: SA-193 GR 87 Nuts: SA-194 GR 2H o) TU fa a J Washers: SA-325 Tv z g tr are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, lnc. Product Engineerlng Department 1 CONTROLREFNO. 6015 o EV The Design Report & Design Specification Materials: t\ o o Certification BERGEN.POWER PIPE SUPPORTS, INC. Sheet lof 3 A PART NO. 6015 FRICTION TYPE ANCHOR STUD DIA. I -f [, 6 6 REO'0. TORQUE REV PIPE A B c D E F G 5 315/16 3ffi 3 3t4 4 3ffi 23t4 23t4 3 3t4 458 4 7t8 3112 23t4 3 3t4 3112 31t4 3 3t4 1 3/16 1 1t4 1 1t4 1 5/8 5 5 5 31n 3314 3 314 H SIZE 1t2 5 41t4 41t4 3t4 5 4114 5 43t4 3/8 1 11t4 5 5114 1ffi 5 5112 2 5 6114 1/8 1/8 3112 4 3 3t4 3/8 3ffi 43t4 3 314 2 STUD PER BOLT DIA. IN-LBS. 5/8 170 5/8 290 5/8 140 5/8 260 2 5/8 300 1n6 5/8 290 5/8 330 2ffi NOTE 1. All dimensions are r- o o in inches and are provided for user application only. ORDERING INSTRUCTIONS: Specify Part Number, CDRS Rev. No. and Pipe Size o) UJ :f a ct> E)GMPLE: 6015-R0-2" J z 0 tr o - G <" REV ffi H BERGEN-POWER PIPE SUPPORTS INC. CDRS CATALOG INFORMATION SHEET PART 6015 DATE 911 t2007 CERTIFIED DESIGN REPORT SUMMARY rH; fl for NUCLEAR POWER PLANT STANDARD SUPPORTS 2-BOLT PIPE CLAMP Hd DIRECTION OF LOADING Temperature:ff NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown lor the Operating Condition. DESIGN SPEC NO.: K ft DESIGN REPORT NO.: DS-6100 R0 DR-6100 R0 Rated Loads (lbs) for Classes 1,2,3 & MC REV Size Design Gondition Level A 1000 1000 1600 1600 1000 1000 1600 1600 2400 2400 2400 2400 3000 3000 3000 3500 2400 4 5 6 I 10 12 14 16 18 20 24 30 OPERATING CONDITIONS Level C Level B 240/0 2400 1330 1330 1500 1500 2128 2128 3192 3192 3192 2400 2400 3600 3600 3600 3600 4500 4500 4500 5250 24AO 3192 3000 3000 3000 3500 3990 3990 3990 11655 Test Condition (see Note) Level D 2000 2000 3200 3200 4800 4800 4800 4800 6000 6000 6000 7000 1330 1330 2128 2128 3192 3192 3192 3192 3990 3990 3990 4555 '*""ttW equirements of the applicable Code. I The Design Report & Design Specification Materials: tr o Plate:5A-36 are in accordance with ASME BPVC Section lll, o) Studs:5A-36 Subsection NF, 2007 Edition and are on file at: L.IJ cn a -.'] 1 tr SE REV ffi CLOUTIER Certilication Nuts: 5A-563 Gr. A Bergen Power Pipe Supports, Inc. Bolts: SA-307 Gr. B Product Engineering Department Cotter pins, Washers, Retainers Exempt (NF-l1 10) SONTROL REF BERGEN.POWER PIPE SUPPORTS, INC. NO. Sheet l-or ! /N 175 PART NO. 6100 2-BOLT PIPE CLAMP UP5ET THREAD5 AFTER TNSTALLATTON (NF-4725) 6i 6i IEV F- o o CD LrJ f a U) J z o & o G G Pipe Size A c D E F 4 4-318 314 4.a,B 3-5/8 5t8 1l4x 5 4-15116 314 4-15t16 4-3tI6 5/8 114x 1-112 6 5-718 7//8 5-718 5 314 318x1-112 I 7 1 7 6-1/8 314 318x1-112 10 8-9/16 1 8-9/16 7-7116 7t8 112x2 12 9-9/16 1 9-9/16 8-7116 718 1li2x2 14 10-s/8 1-1//8 10-5/8 9-1t4 7t8 112x2-112 16 11-518 1-1t8 11-5/8 10-1t4 7t8 112x2-112 18 13 1-114 13 11-518 1 518x2-112 20 14-118 1-3/8 14-118 12-3t4 1 518x2-112 24 16-718 1-5/8 16-7t8 15-1t4 1-1t4 5/8x3 30 20-314 2 20-3t4 18-1t2 1-112 314x4 Stock Size 1-112 NOTES: 1. Clamp shown with bolts. Studs may be used at manufacture's option. ln that case, upset threads at ends after installation. 2. Dimensions provided for user information only. Orderinq lnstructions : Specify part No., CDRS revision No., and size designation. Example: Part 6100 - R/0 - I REV r77f, BERGEN-POWER PIPE SUPPORTS Hfl U CDRS CATALOG INFORMATION SHEET PART 61 OO DATE 91112007 CERTIFIED DESIGN REPORT SUMMARY rf,n fr for NUCLEAR POWER PLANT STANDARD SUPPORTS HEAVY 2-BOLT PIPE CLAMP Hd DIRECTION OF LOADING Temperature:650 Note: f The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) 100f. For higher temperatures in the Test Condition use Level B loads the maximum temperature is up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: F tEV Design Size Condition 3 3-112 4 5 6 8 10 12 14 16 18 3400 3400 3550 3550 4900 4900 6000 8700 50 50 91 50 91 50 91 91 20 DS-6100 R0 DR-6100 R0 Rated Loads (lbs) for Classes 1,2,3 & MC OPERATING CONDITIONS Level C Level B Level A 51 00 4522 3400 4522 51 00 3400 5325 4722 3550 4722 5325 3550 7350 4900 651 7 7350 4900 651 7 7980 9000 6000 1 3050 11571 8700 13725 12170 91 50 13725 12170 91 50 13725 12170 91 50 13725 12170 91 50 Test Condition (see Note) Level D 6800 6800 71 4522 4522 4722 4722 651 7 651 7 7980 11571 12170 00 7100 9800 9800 1 2000 17400 18300 18300 18300 18300 12170 12170 12170 -"ry 'equiremenls of the applicable Code. I The Design Report & Design Specification Materials: Plate:5A-36 are in accordance with ASME BPVC Section lll, Studs: 54-36 Nuts: SA-307 Gr. B Subsection NF, 2007 Edition and are on file at: Bolts: SA-307 Gr. Bergen Power Pipe Supports, lnc. B Product Englneering Department Cotter pins, Washers, Retainers Exempt (NF-11 10) SONTROLREFNO. REV Certification BERGEN.POWEN PIPE SUPPORTS, INC, Sheet lofl 298 REV. PART NO. /a\ 6101 HEAVY 2.BOLT PIPE CLAMP II c UPSET THREADS AFTER TNSTALLATTON (NF-4725) \lJ) 6 tEV Pipe Size A c D E F Stock Size 3 4 7t8 4 3-1/8 3t4 318x2 3-1t2 4-1t4 7t8 4-1t4 3-3/8 314 318x2 4 4-7tA 1 4-7t8 3-3t4 7t8 318x2 5 5-1t2 1 5-1t2 7t8 318x2 6 6-5/8 1-1t8 6-5/8 5-1t4 1 112 x 2-112 I 7-5t8 1-1t8 7-5t8 6-1t4 1 112 x 2-112 10 9-1/8 1-3/8 9-1/8 7-3t4 1-1t4 5/8 x 2-112 12 10-7t8 1-5/8 10-7t8 9-114 1-1t2 314x3 14 11-7t8 1-5l8 11-7t8 10 1-1t2 314 x 3-112 16 12-7t8 1-5t8 12-7 t8 11 1-1t2 314 x 3-112 18 13-7t8, 1-5/8 13-7t8 12 1-1t2 314 x 3-112 20 14-7t8 1-5/8 14-7t8 13 1-1t2 314 x 3-112 NOTES: l- o o F o, 1. Clamp shown with bolts. Studs may be used at manufacture's option. ln that case, upset threads at ends after installation. 2. Dimensions are provided for user application only. uJ f U) a z Orderino lnstructions: Specify part No., CDRS revision No., and size designation. (, [E o G G Example: Part 6101 - R/0 - 10 IEV ffi fl BERGEN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART DATE 6101 9t1t2007 LOAD CAPACITY DATA SHEET for NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS PIPE SADDLE -\- I ./l:r - I DIRECTION rof,iruc TEMPERATURE:650 LOAD RATING DESIGNED BY: T LOAD RATTNG (LBS) for Class 1,2,3 & MC SIZE DESIGN LEVEL A CONDITION NORMAL {o {o \< EUI> 4 6 8 i- o I I ct) ]u d] F zJ- o o J o lu U) ff-t 2 o (9 I (\l 10 12 14 16 18 1 1 000 1 000 200 1 500 2000 2500 3500 4000 6000 7500 11000 11000 OPERATING CONDITIONS LEVEL D LEVEL C EMERGENCY FAULTED 1500 1 500 1500 1 500 1 800 330 1 330 1 330 1 596 1 995 2250 2660 3325 4655 5320 7980 9975 1 4630 3000 3750 5250 6000 9000 1 1250 1 6500 1 1 2000 2500 3500 4000 6000 7500 20 24 30 36 '1330 000 1 000 000 1 000 1 000 1 000 1 200 1 500 1 5 LEVEL B UPSET 1 TEST CONDITION 880 330 330 1 330 1 330 1 596 1 995 2660 3325 4655 5320 7980 9975 14630 1 880 1880 1 880 1 1 2256 2820 3760 4700 6580 7520 11280 14100 20680 uJ E o z E IU @I C\l I o o o L E o E o () UJ ul F- o E(U o o t o) (6 IU o 2 o (L rU tr o = 6 EIJJ> NOTE: I certify that this LCDS complies with the requirements of the applicable code. Materials: gllEo9 Plate: 54-36 Bolts: 9l fg-f gElq rga llll- Prvs! Pin: BERGEN-POWEB PIPE SUPPORTS, INC. \uts: IU Studs: = o o 3otter pins, Washers, Retainers Exempt (NF-1110) g E o wql9ulqtlvll- performed in accordance wlth: ASME BPVC SECTION lll, SUBSECTION NF COMPONENT SUPPORTS 2007 Editlon and are on file at: IFT] ?rI A Product Engineering Department CONTROLREF. BERGEN-IowER ptpE suppo+rs, INc. LoAD cAPActrY DATA SHEET NO. Sheet _!of 1 A REV. 6140 ,ART N( 61 40 COVERING THfCKNESS PIPE Tr VIEW A-A NOTES: = 4" c stzE 4 61t2 5 L 4 oo T T, 7t16 20" 3/16 7 413t16 20" 3/16 6 7 1t2 5 3/16 20" 3/16 8 8 3t4 6 20" 1t4 10 I3t4 611/16 20" 1t4 12 10 3t4 11 15/16 30" 3/16 3/16 14 11 1t4 12 9t16 30., 1t4 3/16 16 12 1t4 131t2 30" 1t4 1t4 18 131t4 14 5t8 30" 1t4 1t4 20 141t4 15 3t4 30" 1t4 1t4 24 161t2 30" 3/8 3/8 30 191t2 21 1t2 300 3/8 3/8 36 221t2 30" 3/8 3t8 18 25 1. All dimensions are in inches. 2. Dimensions are orovided for user application onlv. ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation. EXAMPLE: r77; H HJ 6140-R/3- 8" BERGEN.POWER PIPE SUPPORTS INC. CATALOG INFORMATION SHEET PART DATE 6140 9t112007 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS 3.BOLT PIPE CLAMP DIRECTION OF LOADING Temperature: 650 Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100 F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: REV Size f Design Condition 500 500 1 500 1 500 1 500 2500 2500 2800 2800 3200 3200 4300 4300 4300 5500 6000 8000 8000 1-112 2 2-112 3 3-112 1 1 4 5 6 8 10 12 14 16 18 20 24 30 36 DS-6100 R0 DR-6100 R0 Rated Loads (lbs) for Classes 1,2,3 & MC OPERATING CONDITIONS Level C Level B Level A 2250 1 995 1 500 2250 1 995 1 500 2250 1995 1 500 2250 1 995 1 500 2250 1 995 1 500 3325 3750 2500 2500 2800 2800 3200 3200 3325 4300 4300 571 3724 3724 4256 4256 I 5719 5719 7315 4300 5500 6000 8000 8000 7980 1 0640 1 0640 3750 4200 4200 4800 4800 6450 6450 6450 8250 9000 1 2000 1 2000 Test Condition (see Note) Level D 3000 3000 3000 995 995 1995 1995 1995 1 1 3000 3000 5000 5000 5600 5600 3325 3325 3724 3724 4256 4256 6400 6400 8600 I I 571 I 571 8600 8600 11000 571 7315 7980 0640 1 0640 2000 1 6000 1 6000 1 1 I certify this CDRS complies with the equirements of the applicable Code. The Design Report & Design Specilication Materials: tr o o Plate:5A-36 Pin:54-36 o) uJ f U) 9. J z Bergen Power Pipe Supports, lnc. Bolts: SA-307 Gr. Product Englneering Department B loNlH9L HEF NO. 304 PATII N(,. R REV Studs: 5A-36 Nuts: 5A-563 Gr. A Cotter pins, Washers, Retainers Exempt (NF-1110) 0 tr o \\ are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: BERGEN-POWER PIPE SUPPORTS, INC. Certification Sheet lofl K 6150 3.BOLT PIPE CLAMP -.l LJI F I F c f 6 PIPE G c D E 1-112 1-1/16 +7t8 +1t8 2 1.1n6 5-7t8 2.1t2 1.1/16 3 F S 114x1-112 5/8 2.3t8 5-1/8 114x1-112 5/8 2.3t4 6-1/4 5-112 114r1-112 5/8 3-1/16 1.1/16 6-11/16 5-15/16 114x1-112 5/8 3-3/8 3-112 1.1/16 6-15/16 G3/16 114x1-112 5/8 3-5/8 4 1-1/16 7-5t8 6-112 318x2 3t4 4.112 5 1.1 /1 6 8-1/8 7 318x2 3t4 5 6 1-7t16 10 8-5/8 318x2-112 1 6.3/16 I 1.7t16 1&15/16 9-9/16 318x2-112 1 7-1t8 10 1-7t16 12.1t8 10-5/8 112x2-112 1 8-3/4 12 1.7116 13-114 11-7t8 112x2-112 1 9.1t2 14 2 14.5/8 13 5/8x3 1-114 11 16 2 15-7/16 13.13/16 5/8x3 1,114 18 2 16-1t2 14-718 5/8x3 1-114 12.7t8 20 2 17.7t8 16-1/4 3/4x3 1-112 1e3/8 24 2 19.11/16 18.1/16 314x4 1-112 16-3/16 30 2 26-1t2 24 1x5 1-314 20 36 2 30 27.1t2 1x5 1-3t4 2X1t2 srzE Stock STOCK srze UP5ET THREAD5 AFTER TNSTALLATTON (NF-4725) 6 6 lEV l- o o o, [! :) F 1 1.13/1 6 NOTE: studs instead of bolts. 2. Dimensions provided for user application only. 1. Sizes 30 & 36 use U) I J z (, (f s o G lEV E7; U Orderinq lnstructions: Specily part No., CDRS revision No., and size designation. Example: Part 6150- R/0 - 4 BERGEN-POWER PIPE SUPPORTS Hd CDRS CATALOG INFORMATION SHEET PART DATE 6150 9t1t2007 ffi CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS HEAVY 3-BOLT PIPE CLAMP E DIRECTION OF LOADING Temoerature: 650 NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC 7 (') NO.: NO.: DS.61OO RO DR.61OO RO DESIGN REPORT Rated Loads 0bs for Classes 1,2,3 & MC OPERATING CONDITIONS Level C Level B Level A 2250 1 995 1 500 2250 1 995 1 500 2250 1 995 1 500 REV Size Design Condition 500 500 1 500 5000 8000 8000 11000 11000 314 1 1 1 1-114 5 6 8 10 12 14 16 18 20 24 28 30 36 5000 8000 8000 1 1000 11000 12700 12700 12700 12700 12700 12700 5000 1 5000 1 5000 1 5000 1 5000 1 5000 1 5000 1 5000 1 5000 1 5000 1 equirements of the applicable Code. 6891 6891 1 6891 7500 2000 1 2000 16500 1 6500 1 9050 1 9050 1 9050 9950 9950 1 9950 1 9950 1 9950 22500 22500 22500 22500 22500 6650 0640 1 0640 1 4630 1 4630 1 1 1 1 1 1 o o Pin:54-36 o, Test Condition (see Note) Level D 1995 1995 1995 6650 1 0640 1 0640 1 4630 1 4630 3000 3000 3000 0000 6000 1 6000 22000 22000 25400 25400 25400 30000 30000 30000 30000 30000 1 1 6891 6891 1 6891 1 1 9950 19950 1 9950 1 9950 1 9950 1 I Materials: )late: 54-36 t-. The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: uJ l Studs: 5A-36 U) I J z Nuts: SA-307 Gr. B Bergen Power PiPe SuPPorts, lnc. Bolts: SA-307 Gr. B Cotter pins, Washers, Retainers Exempt (NF-1110) Product Englneerlng DePartment q E o ffi f L;ON IHL)L HEF 91 PART NO. R REV NU. BERGEN.POWER PIPE SUPPORTS, INC. Certification Sheet Lor ! /il. 6152 3-BOLT PIPE CLAMP F tJr - f PIPE c D E F s Stock Size 5/8 4.7t16 3-1ln6 5/8 1-15n6 114x1-112 1 5t8 4-5/8 3-7t8 5/8 2.1t8 114x1-112 1-1t4 5/8 4-3t4 4 5/8 2-1t4 114x1-112 5 1.1t2 9-3/4 7-3t4 1.114 6 112x3 6 1.3t4 11.1t4 I FN 7.3t4 112x4 8 1-3t4 12-1t4 10 fin 8-5/8 112x4 10 2 14.3/8 12 1-3t4 10-3/4 314x4 12 2 15-3/8 13 1.3t4 11-5/8 314x4 14 2.1t4 16-7/8 14 2 12-1t2 7l8xh1l2 16 2-114 17.7t8 15 2 13.1t2 718x4-112 18 2-1t4 18.7/8 16 2 fl.1n 718x4-112 20 2-1t4 21 18 2 16-1t4 1x5 24 2-114 23 20 2 ft-1n 1-1/8 x 6 2g 2-1t4 27.1n 24 2 20-1t2 1-1/8 x 6 30 2-1t4 28-1t2 25 2 21-112 1-1/4 x 6 36 2-1t4 31.1t2 28 2 24.1t2 1-1/4 x 6 stzE 314 G sTOCK STZ;E UP5ET THREADS AFTER INSTALLATTON (NF-4725) cl 6x REV ro o d uJ :) a a J (t = (r o AKrc NOTE: 1. Glamp shown with bolts. Studs may be used at manufacture's option. 2. Dimensions provided for user application only. Orderino lnstructions : Specify part No., CDRS revision No., and size designation. Example: Part 6152- R/0 - 4 REV ffi Y BERGEN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART 61 52 DATE 9t1t2007 tit L CERTIFIED DESIGN REPORT SUMMARY for d b NUCLEAR POWER PLANT STANDARD SUPPORTS YOKE CIAMP RESTM'NT af-- . PART NUMBER 6T75..7K af-- 10' 10' DIRECTION OF LOADING I I I I Temperature: *o"t Design Spec. No. DS-6175 Design Report No. DR-6175 Fo, the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Condition 3 700 700 931 4 700 700 931 Level A Test Gondition (see Notel 1,050 1,106 931 1,050 1,106 931 1,106 931 700 700 931 1,050 6 700 700 931 1,050 1,106 931 I 700 700 931 1.050 1,106 931 10 700 700 931 1,050 ,106 931 12 700 700 931 1,050 1,106 931 Rated loads (lbs) for C/asses 1,2,3 &MC CONTROLREFNO. certfy 0ris CDRS complies wilh $e requircments of lhe applcable Level D Operating Conditions Level B Level C Size 5 I 6500F mde MATERIALS 6175 The Design Report & Design Specification are in Yoke: SA-515 Gr70 U-Bolt SA-193 87 Nuts: SA-194 2H accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 5A-564 TYP 630 Bergen Power Pipe Supports,lnc. Studs: N/A Product Engineering DePartment Exempt Cofters, Washers, Retainers, Shims (NF-2121) REVISIONS *sL,(.4'e $EAL l/a/tz/ag lslGNED /il Orioinal lssue 10/27109 A /^ BERGEfV POWER PIPE SUPPORTS, INC, /J /i /i SHEET 1 OF 1 REv. a PART N0. 6175..7 CDRS CATALOG INFORMATION SHEET YOKE CAMP RESTRA'NT . PART NUMBER 6175.,7K *Q PIPE SIZE c D E t, P 3 51t2 3t4 6 1t2 3/8 7,5 1 61t2 112 3/8 7.5 1 3/8 7.5 1 FT.LBS T 4 6 3/8 3t4 5 7 3t4 7 1t16 112 6 I3t4 314 7 9116 1t2 3/8 7.5 1 9/16 1t2 3/B 7.5 1 518 I 314 3t4 10 12718 3t4 10 5/8 112 3/8 7.5 1 12 147t8 314 11 5/8 1t2 3/8 7.5 1 8 10 1.)Alldimensions are in inches. * 2.) Dimensions are provided for user application only' 3.) Minimum spring rate by test = 500 kips / in' 4.)This Clamp is compatible with B-P Parts 2015,2250,2252,2420 and2440. 5.) Torque Q tolerance = +l'10o/o ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size. EMMPLE: 6175-.7-R/0-8. Oriqinal Issue 1 0/27109 BERG SHEET 1 OF EN POWER PIPE SUPPORTS, 'NC. 1 PART N0. 6175..7 titD, CERTIFIED DESIGN REPORT SUMMARY for d H NUGLEAR POWER PLANT STANDARD SUPPORTS YOKE CUMP RESIRA''VT. PART NUMBER6l75-1.5K ar- aF- 10" 10" DIRECTION OF LOADING I I I Temperature: No"' Design Spec. No. D96175 Design Report No. DR-6175 Size Fo, the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Gondition Level A Operating Conditions Level B Level G Level Test Condition (see Notel D 1,995 3 1,500 1,500 1,995 2,250 2,370 1 1,500 1,500 ,l,500 1,995 2,250 2,370 1,995 1,995 2,250 2,370 1,995 5 1,500 6 1,500 1,500 1,995 2,250 2,370 1,995 8 1,500 1,500 1,995 2,250 2,370 1,995 10 1,500 1,500 1,995 2,250 2,370 1,995 12 1,500 1,500 1,995 2,250 2,370 1,995 Rated Loads (lbs) for C/asses 1,2,3 I certity this CDRS complies with 6sooF &MC CONTROLREFNO. he MATERIALS mquirements of the applicable code 6175 The Design Report & Design Specification are in Yoke: SA-515 Gr70 U-Bol[ SA-193 87 Nuts: SA-194 2H accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on flle at: Pin: 5A-564 TYP 630 Bergen Power Pipe Supports , lnc. Studs: N/A xempt: Cotters, Washers, Retainers, Shims (NF-2121) Product Engineering DePartment REVtSt0NS Eeit,(.il,,e SEAL l/a,hz/af ISIGNED /il Oriqinal lssue 10/27109 /^ BERGEfV POWER PIPE SUPPORTS, INC, /t /^ /J SHEET 1 OF 1 REv. a PART N0. 6175.1.5 CDRS CATALOG INFORMATION SHEET . YOKE CLAMP RESTRIIINT PART NUMBER 6175.1.5K *Q E t, 314 6 5/8 1t2 32 1 3t4 6112 5/8 1t2 32 1 5/8 1t2 32 1 c D 3 51t2 4 6 3/8 5 7 518 3t4 6 8314 3t4 PIPE SIZE 7 1t16 P FT.LBS T 314 3t4 7 9t16 I 9/16 10 12718 3t4 10 5/8 5/8 1t2 32 1 12 147t8 3t4 11518 5/8 1t2 32 1 I 10 5/8 1t2 32 1 5/8 1t2 32 1 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only' 3.) Minimum spring rate by test = 600 kips / in' 4.) This Clamp is compatible with B-P Parts 2015,2250,2252,2420 and 2440' * 5.) Torque Q tolerance = +l- 10o/o ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size' DGMPLE: 6175-1,5-R/0-8" REVISIONS lssue 10/27109 BERG EN POWER PIPE SUPPORTS, INC. PART NO. 6175.1.5 I CERTIFIED DESIGN REPORT SUMMARY i"l NJ, for b NUCLEAR POWER PLANT STANDARD SUPPORTS YOKE CLAMP RESTRII'NT . PART NUMBER 6175.4K -1f-- "iF_ i- 10" DIRECTION OF LOADING I I I I Temperature: Nott' Design Spec. No. DS-6175 Design Report No. DR-6175 For, the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Size Design Condition Level A OperatinE Gonditions Level B Level G Level D Test Condition (see Notc) 3 4,000 4,000 5.320 6,000 6,320 5,320 4 4,000 4,000 5,320 6,000 6,320 5,320 5 4,000 4,000 5,320 6,000 6,320 5,320 6 4,000 4,000 5,320 6,000 6,320 5,320 I 4,000 4,000 5,320 6,000 6,320 5,320 10 4,000 4,000 5,320 6,000 6,320 5,320 12 4,000 4,000 5,320 6,000 6,320 5,320 14 4,000 4,000 5,320 6,000 6,320 5,320 16 4,000 4,000 5,320 6,000 6,320 5,320 Rated Loads (lbs) for C/asses 1,2,3 I certify this CDRS 6500F &MC CONTROLREFNO. mmdies wi$ he MATERIALS rcquirements of lhe applicable code 6175 The Design Report & Design Specification are in Yoke: SA-515 Gr70 accordance with ASME BPVC Section lll, Subsection U-Bolt SA-193 87 Nuts: SA-194 2H NF 2007 Edition and are on file at: Pin: SA-564 TYP 630 Bergen Power Pipe Supports, lnc. Studs: N/A Product Engineering Department Exempt: Cotters, Washers, Retainers, Shims (NF-2121) REVISIONS t#hR.(4fr SEAL lza /zz,/af I SIGNED /dr I Orioinal lssue 1 /3\ 0/27109 /i /i 1 l/z\ BERGEN POWER PIPE SUPPORTS, SHEETl OF 1 'NC. REV. A PART N0. 6175-4 CDRS CATALOG INFORMATION SHEET YOKE CLAMP RESIRA'AJT - PART NUMBER 6175.4K *Q P 6 5/8 6112 5/8 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 D 3 51t2 3t4 4 6 3/B 3t4 5 7 5t8 314 7 1t16 5/8 6 8 314 3t4 7 9/16 5/8 8 10 3t4 314 9/16 5/8 10 12718 314 10 5/8 5/8 12 147t8 3t4 115t8 5/8 14 16 1/8 3t4 12114 5/8 3t4 131t4 5/8 16 * t c PIPE SIZE 18 1/8 E I FT.LBS T 32 11t4 11t4 11t4 32 1 1t4 32 32 32 32 11t4 11t4 11t4 32 1 1t4 32 1 1t4 32 1.) All dimensions are in inches' 2.) Dimensions are provided for user application only' 3,) Minimum spring rate by test = 1000 kips / in. 4.)This Clamp is compatible with B-P Parts 2015,2250,2252,2525 and 2530. 5.) Torque Q tolerance = +l'10o/o ORDERING INSTRUCTIONS : Specify: Part Number, CDRS Revision Number, and Pipe Size' EXAMPLE: 61754-R/0-8" BERG EN POWER PIPE SUPPORTS, INC, PARr N0. 6175.4 tit t, CERTIFIED DESIGN REPORT SUMMARY for d H NUCLEAR POWER PLANT STANDARD SUPPORTS YOKE CLAMP RESIM"VT . PART NUMBER 6175.7K ar- "1D- 10' DIRECTION OF LOADING + I I I Temperature: t No"' Design Spec. No. D96175 Design Report No. DR-6175 6sooF Fo, the test condition (Hydro)the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition, Size Design Condition Level A Operating Gonditions Level B Level G Level D Test Condition (see Notel 3 7,000 7,000 9,310 10,500 11,060 9.310 4 7,000 7,000 9,310 10,500 11,060 9.310 5 7,000 7,000 9,310 10,500 11,060 9,310 6 7,000 7,000 9.310 10,500 11,060 9,310 8 7,000 7,000 9,310 10,500 11,060 9,310 10 7,000 7,000 9,310 10,500 11.060 9,310 12 7,000 7,000 9,310 10,500 11,060 9,310 14 7,000 7,000 9,310 10,500 11,060 9.310 9,310 10,500 11,060 9,310 9,310 t6 7,000 7,000 18 7,000 7.000 9,310 10,500 11,060 20 7,000 7,000 9,310 10,500 11,060 9,310 24 7,000 7,000 9,310 10.500 11,060 9,310 30 7,000 7,000 9,310 10,500 11.060 9,310 Rated Loads (lbs) tor C/asses 1,2,3 &MC I cerlify this CDRS CONTROLREFNO. mmplies with he requirements of the applicable code MATERIALS 6175 The Design Report & Design Specification are in Yoke: SA-515 Gr70 U-Bolt SA-193 87 Nuts: SA-194 2H accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 5A-564 TYP 630 Bergen Power Pipe Supports, Inc. Studs: NiA Product Engineering Department Exempt Cotters, Washers, Retainers, Shims (NF-2121) REV|St0NS e4'kr(.U'e /il Oriqinal lssue 1 0/27109 A lopz/ol lsrcNED /^ BERGEfV POWER PIPE SUPPORTS, INC, s1n /3\ /t\ /J SHEET 1 OF 1 REV. A PART NO. 6175.7 CDRS CATALOG INFORMATION SHEET . YOKE CLAMP RESTRAI'VT PART NUMBER 6175.7K t_ I D I E I t I *Q PIPE SIZE c D E IJ P FT.LBS T 3 6 314 1 1t4 I 7t8 314 125 4 7 314 1 1t4 81t2 7t8 3t4 125 1314 6 9718 1114 9 718 3t4 125 11t4 11t4 11t4 10 7t8 314 125 3t4 125 314 125 8 11718 10 14 12 16 9/16 9/16 13t4 314 125 3t4 125 13t4 13t4 13t4 13t4 13t4 13t4 3t4 19114 1 1t4 14114 18 21114 11t4 15114 7t8 7t8 7t8 7t8 7t8 125 1314 20 231t4 1 1t4 16114 7t8 3t4 125 1314 24 27 1 1t4 18114 7t8 3t4 125 30 33114 1 23114 7t8 3t4 125 13t4 13t4 14 16 17 114 114 1 1t4 114 11518 12518 13114 1.) All dimensions are in inches. 2,) Dimensions are provided for user application only' 3.) Minimum spring rate by test = 1500 kips / in. * 4.)This Clamp is compatible with B-P Parts 2250,2252,2420,2440,2525 and 2530' 5,) Torque Q tolerance = +l- 10o/o ORDERING INSTRUCTIONS : Specify: Paft Number, CDRS Revision Number, and Pipe Size' DGMPLE: 6175-7-R/0-B' inal lssue 10127109 SHEET 1 OF BERGEN POWER PIPE SUPPORTS, 'NC. 1 PART N0. 6175-7 titr, CERTIFIED DESIGN REPORT SUMMARY for ffif E NUCLEAR POWER PLANT STANDARD SUPPORTS YOKE CUMP RESTRA'TVT . PART NUMBER 617&12K ,-1f'- -1f-'- 10" DIRECTION OF LOADING I I I I *ottt Design Spec. No. D96175 Design Report No. DR-6175 6sooF ,0r, the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Test Gondition Operating Gonditions Level C Level B Size Design Condition 3 12,000 12,000 15.960 4 12,000 12,000 5 12,000 6 Level D (see Note) 18,000 18,960 15,960 15,960 18.000 18,960 15,960 12.000 15,960 18.000 18.960 15,960 12,000 12,000 15,960 18,000 18,960 15,960 I 12,000 12,000 15,960 18,000 18,960 15,960 10 12,000 12,000 15,960 18,000 18,960 15,960 12,000 12,000 15,960 18,000 18,960 15,960 14 12,000 12,000 15,960 18,000 18,960 15,960 16 12,000 12,000 15,960 18.000 18,960 15,960 18 12,000 12,000 15,960 18,000 18,960 15,960 20 12,000 12,000 15,960 18,000 18,960 15,960 24 12,000 12,000 15,960 18,000 18,960 15,960 30 12,000 12,000 15,960 18,000 18,960 15,960 12 Rated I certify this CDRS complies Temperature: Level A foads (lbs) for C/asses 1,2,3 &MC CONTROLREFNO. wih he MATERIALS rcquirements of the applicaHe code 6175 The Design Report & Design Specification are in Yoke: SA-515Gr70 U-Bolt SA-193 87 accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Nuts: SA-194 2H Pin: 3A-564 TYP 630 Bergen Power Pipe SuPqorts,lnc, Studs: N/A Exemptfotters, Washers, Retainers, Shims (N F-2 1 Produc't Engineering Department 21 ) REVISIONS t4;qft.4,e $EAL Va/22/a?lslGNED /i' /3\ Oriqinal lssue 1 0/27109 /T /A /^ /s\ BERGEN POWER PIPE SUPPORTS, SHEET 1 ''VC. 0F 1 REv. a PART N0. 6175.12 CDRS CATALOG INFORMATION SHEET YOKE CLAIIIP RESTRA'NT . PART NUMBER 6175.12K 1[-10" i ir E I I I i l<_ T I *Q PIPE SIZE c E D I G P 7t8 7t8 3t4 3t4 3t4 3t4 3t4 3 63t4 1 4 7 314 11t4 6 97t8 1 1t4 I 9/16 7t8 1 10 9/16 7t8 11 5/8 I 11718 10 14 12 16 14 17 16 191t4 18 114 21114 114 114 81t2 125 1314 125 3t4 125 3t4 125 125 125 1314 125 1314 13t4 13t4 114 13114 1 1t4 141t4 7t8 1 1t4 15114 7t8 7t8 3t4 3t4 3t4 1 125t8 12s 125 125 20 23114 11t4 161t4 24 27 1 114 181t4 7t8 3t4 125 30 33114 1 1t4 23114 7t8 3t4 125 114 T 13t4 13t4 13t4 13t4 13t4 13t4 13t4 7t8 7t8 7t8 11t4 11t4 FT.LBS NOTES: 1.) All dimensions are in inches. 2,) Dimensions are provided for user application only' * 3.) Minimum spring rate by test = 1500 kips / in. 4.) This Clamp is compatible with B-P Parts 2250,2252,2525 and 2530. 5.) Torque Q tolerance = +l- 10o/o ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size' EMMPLE: 6175-12-R/0-8" REVISIONS PART BERGEN POWER PIPE SUPPORTS, 'NC. NO. 6175-12 ti/It CERTIFIED DESIGN REPORT SUMMARY for d Y NUCLEAR POWER PLANT STANDARD SUPPORTS YOKE CLAMP RESTRA'IVT - PART NUMBER 6175.25K -1f- -1r.-- 10' DIRECTION OF LOADING I I I I nott' Design Spec. No. D96175 Design Report No. DR-6175 certify this CDRS complies with 6sooF For' the test condition (Hydro)the maximum temperature is 100oF. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition, Size Design Condition 6 25,000 Level A Test Condition Operating Gonditions Level B Level G Level D {see Note} 33,250 25,000 33,250 37,500 39,500 37,500 39,500 33,250 39,500 33,250 8 25,000 25.000 33,250 10 25,000 25,000 33,250 37,500 12 25,000 25,000 33,250 37,500 39,500 33,250 14 25,000 25,000 33,250 37,500 39,500 33,250 16 25,000 25,000 33,250 37,500 39,500 33,250 18 25,000 25,000 33,250 37,500 39,500 33,250 20 25,000 25,000 33,250 37,500 39,500 33.250 24 25,000 25,000 33,250 37,500 39,500 33,250 30 25,000 25,000 33,250 37,500 39,500 33,250 36 25,000 25,000 33,250 37.500 39.500 33,250 Rated I Temperature: loads (lbs)for C/asses 1,2,3 &MC CONTROL REF NO. fte MATERIALS requirements ol the applicaFrle code 6175 The Design Report & Design Specification are in Yoke: SA-515Gr70 U-Bolt SA-193 87 accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Nuts: SA-194 2H Pin: 5A-564 TYP 630 Bergen Power Pipe Supports, Inc. Studs: N/A Product Engineering Department Exempl Cotters, Washers, Retainers, Shims (NF-2121) REV|S|ONS SEAL lta,/zt,/,t f ISIGNED /il, lOriqinal lssue 1 0/27109 /3\ /N /t\ /t\ /A BERGEfV POWER PIPE SUPPORTS, SHEET 1 OF 'NC, t REv. a PART NO. 6175.25 CDRS CATALOG INFORMATION SHEET YOKE CLAMP RESIRA'NT . PART NUMBER 6175.25K L-l f- 10' D I L TJ i *Q * PIPE SIZE c D 6 10 5/8 8 T E G P 2 10 9/16 1 3/8 1 200 21t2 125t8 2 11 9/16 1 3/8 1 200 21t2 10 14 314 2 5/8 1 3/8 1 200 2112 12 16314 2 12 13 5/8 1 3/8 1 200 21t2 14 18 2 14 1t4 1 3/8 1 200 2112 16 20 2 200 21t2 22 2 13t8 13t8 1 18 1 200 21t2 20 24 2 1 3/8 1 200 24 28 2 1 3/8 1 200 21t2 21t2 30 34 2 1 3/8 1 200 2112 36 40 2 15 114 16 114 17 1t4 21 114 24 114 27 114 1 3/8 1 200 21t2 FT.LBS 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only' 3.) Minimum spring rate by test = 2000 kips / in' 4.)This Clamp is compatible with B-P Parts 2250,2252,2420,2440,2525 and 2530. 5.) Torque Q tolerance = +l'100/o ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size. EXAMPLE: 6175-25-R/0-8' lssue 10/27109 BERG EN POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 PART N0. 6175-25 til I' CERTIFIED DESIGN REPORT SUMMARY for d b NUCLEAR POWER PLANT STANDARD SUPPORTS YOKE CLATIIP RESIRA'IVT '1f.-- . PART NUMBER 6175.35K -1f'-- 10" 10' DIRECTION OF LOADING Temperature: 6500F For the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature Design Spec. No. DS-6175 Design Report No. DR-6175 shown for the Operating Condition. Size Design Condition Level A Operatins Conditions Level C Level B Level D Test Condition (see Notel 46,550 12 35,000 35,000 46,550 52,500 55,300 14 35,000 35,000 46,550 52,500 55,300 46,550 16 35,000 35,000 46,550 52,500 55,300 46,550 18 35,000 35,000 46,550 52,500 55,300 46,550 20 35,000 35,000 46,550 52.500 55,300 46,550 24 35,000 35,000 46,550 52,500 55,300 46,550 30 35,000 35,000 46,550 52,500 55,300 46,550 36 35,000 35,000 46,550 52,500 55,300 46,550 Rated Loads (lbs) for C/asses 1,2,3 & MC I ceftify this CDRS complles CONTROLREFNO. wifi the MATERIALS rcquirements of the applicable code 6175 The Design Report & Design Specification are in Yoke: SA-515 Gr70 accordance with ASME BPVC Section lll, Subsection U-Bolh SA-193 87 Nuts: SA-194 2H NF 2007 Edition and are on file at: Pin: 3A-564 TYP 630 Bergen Power Pipe Supports,lnc. Studs: N/A Product Engineeilng Department Eiempt Cotters, Washers, Retainers, Shims (NF-2121) REVISI0NS 8.jt:.".tr.&6 /il\ Orioinal lssue 10/27109 /^ A /t sEAt lta/tz/d?ISIGNED /z\ /5\ BERGEII, POWERPIPE SUPPORTS, NC. SHEET 1 0F I REv. a PARTNo. 6175.35 titJ, CDRS CATALOG INFORMATION SHEET d YOKE CLATTP RESIRA'NT . PART NUFIIBER 6175-35K *Q PIPE SIZE c D T t5 P 13 3/8 11t2 1 1t4 600 3 14 1 1t2 1114 600 3 15 11t4 11t4 11t4 600 3 600 3 600 3 E FT.LBS 18 21t2 18 314 21t2 20 314 21t2 223t4 21t2 20 24 314 2112 17 11t2 11t2 11t2 24 28 3t4 2112 20 1112 1 1t4 600 3 30 34 314 2112 24 1114 600 3 36 40 314 21t2 27 1t4 11t2 11t2 11t4 600 3 12 14 16 17 1t2 16 NOTES: 1.)Alldimensions are in inches. 2.) Dimensions are provided for user application only. 3.) Minimum spring rate by test = 3000 kips / in. 4.)This Clamp is compatible with B-P Parts 2250,2252,2525 and 2530. * 5.) Torque Q tolerance = +l- 10o/o ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size' EXAMPLE: 6175-35-R/0-20" REVISIONS /i\ I Oriqinal lssue 10127 109 /3\ /1' /i A /s' BERGEN POWER PIPE SUPPORTS, NC, SHEET 1 OF 1 REV. A PART N0. 6175.35 tit*L CERTIFIED DESIGN REPORT SUMMARY for Y NUCLEAR POWER PLANT STANDARD SUPPORTS YOKE CUMP RESIRA'IVT . PART NUMBER 6175.60K -1f-- -1;-_ 10' DIRECTION OF LOADING I I l I t Temperature: Nott' Design Spec. No. D96175 Design Report No. DR-6175 Fo, the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Test Condition Operatins Conditions Level C Level B Size Design Condition 12 60,000 60,000 79,800 14 60,000 60,000 16 60,000 18 Level D (see Note) 90,000 94,800 79,800 79,800 90,000 94,800 79,800 60,000 79,800 90,000 94.800 79,800 60,000 60,000 79,800 90,000 94,800 79,800 20 60,000 60,000 79,800 90,000 94,800 79.800 24 60,000 60.000 79,800 90,000 94,800 79,800 30 60,000 60,000 79,800 90,000 94,800 79,800 60,000 60,000 79,800 90,000 94,900 79,800 36 6500F Level A Rated Loads (lbs)for Classes 1,2,3 &MC NO. CONTROLREF I certify this CDRS complies with the IIATERIALS rcquirements of the applicabh code 6175 The Design Report & Design Specification are in Yoke: SA-515 Gr70 U-Bolt SA-193 87 Nuts: SA-194 2H accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 5A-564 TYP 630 Bergen Power Prpe Sup porh, lnc, Studs: N/A Product Engineering Department Exempt Cotters, Washers, Retainers, Shims {NF-2121) REV|St0NS &.>/,&a /o\ Oriqinal lssue 1 0/27109 /i #.AL Va/zz/a/lslGNED /i BERGEN POWERPIPE SUPPORTS, NC, /i /r\ /s\ SHEET 1 OF 1 REV. A PART N0. 6175.60 JJtrj I' CDRS CATALOG INFORMATION SHEET rd bd YOKE CLAMP RESTRN'NT . PART NUMBER 6175.60K *Q * t: P 15 1/8 111116 1112 1000 3112 2112 16 111t16 1000 31t2 21t2 21t2 21t2 17 1t4 111116 1000 181t2 111t16 19 3t4 111116 3112 3112 3112 2112 2112 2112 22114 111t16 26 111116 11t2 11t2 11t2 11t2 11t2 11t2 29 111t16 1112 1 PIPE SIZE c D E 12 181t4 21t2 14 16 191t2 211t2 18 23112 20 25112 24 291t2 30 35112 36 411t2 T FT.LBS 1000 1000 1000 31t2 1000 3112 3112 000 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only' 3.)This Clamp is cornpatible with B-P Parts 2250,2252,2421,2440,2525 and 2530. 4.)Torque Q toleranca= +l- 100/o ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size' DGMPLE: 6175-60-R/0-20" REVISIONS Al6qrnal lsa ie lOtZt tOg 3 /r\, /N )\ /s\ ,/ BERGEfV POWER PIPE SUPPORTS, INC, SHEET 1 0F 1 REV. A PART N0. 6175.60 tit D, CERTIFIED DESIGN REPORT SUMMARY for d H NUCLEAR POWER PLANT STANDARD SUPPORTS YOKE CLATtrP RESTRA''VT . PART NUMBER 6175.80K af-- il'-- to' DIRECTION OF LOADING I I + Temperature: Nott' Design Spec. No. D96175 Design Report No. DR-6175 Size 12 6sooF Fo, the test condition (Hydro)the maximum temperature is 1000F, For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Condition 80,000 Level A Test Condition Operating Conditions Level C Level B {see Note) Level D 80,000 106,400 120,000 126,400 106,400 120,000 126,400 106,400 14 80,000 80,000 106,400 16 80,000 80,000 106,400 120,000 126,400 106,400 18 80,000 80,000 106,400 120,000 126,400 106,400 20 80,000 80,000 106,400 120,000 126,400 106,400 24 80,000 90,000 106.400 120,000 126,400 106,400 30 80,000 80,000 106,400 120,000 126,400 106,400 36 80,000 80,000 106,400 120,000 126,400 106,400 Rated Loads (lbs) for C/asses 1,2,3 & MC I certity CONTROL REF NO. ttis CDRS complies with fie requirements of the applicable ode MATERIALS 6175 The Design Report & Design Specification are in Yoke: SA-515 Gr 70 U-Bolt SA-193 87 Nuts: SA-194 2H accordance with ASME BPVC Section lll, Subsection Pin: 3A-564 TYP 630 Bergen Power Pipe SuPPot{g lnc. NF 2007 Edition and are on file at: Studs: N/A Product Engineering DePartment fxernptl Cotters, Washers, Retainers, Shims (NF-z121) REV|StONS fuK,&a SEAL ltaAz/o? /d\ Oriqinal lssue A lslGNED /z\ |/i 10/27109 ) -T BERGEAJ POWERPIPE SUPPORTS, INC. t, J $HEET 1 0F I REV. A PART N0. 6175.80 CDRS CATALOG INFORMATION SHEET YOKE CLAMP RESTruI'AJT . PART NUMBER 6175.80K i_ 1l-'o' L- r P *Q PIPE SIZE c D E 12 18112 3114 T TJ P 15 3/8 113t16 1314 525 6 31t4 17 113116 525 6 22 3114 18 113116 52s 6 18 24 31t4 19 113t16 13t4 13t4 13t4 525 6 20 26 3114 20 1 13/16 1314 525 6 24 30 31t4 23 113t16 525 6 30 36 3114 27 1 13/16 525 6 36 42 31t4 321t2 113t16 13t4 13t4 13t4 525 6 14 16 20 FT.LBS 1,) All dimensions are in inches. 2.) Dimensions are provided for user application only' 3.)This Clamp is compatible with B-P Parts 2250, and2252' * 4.) Torque Q toleranca = +l^ 10o/o ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size. DGMPLE: 6175-80-R/0-20" PART BERGEN POWER PIPE SUPPORTS, 'NC. N0. 6175.80 tit*J, CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS E YOKE CLAMP RESTRA'IVT . PART NUMBER6175.13OK ar- -1l-- 10" DIRECTION OF LOADING i I I i *ottt Design Spec. No. D96175 Design Report No. DR-6175 Size Temperature: 6500F the test condition (Hydro) the maximum temperature is 100oF, For higher ,0, temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Condition Level A Operating Conditions Level B Level C Level D Test Condition (see Note) 14 130,000 130,000 172,900 195,000 205,400 172,900 16 130,000 130,000 172,900 195,000 205,400 172,900 18 130,000 130,000 195,000 205,400 172,900 20 130,000 130,000 fi2,904 fi2,904 195,000 205,400 172,900 24 130,000 130.000 172,900 195,000 205,400 172,900 30 130,000 130,000 172,900 195,000 205,400 172,900 36 130,000 130,000 172,900 195,000 205.400 fi2,904 Rated Loads (lbs) for Classes 1,2,3 & MC I certify this CDRS complies with CONTROLREFNO. fie MATERIALS requirements of the applicabb code 6175 The Design Report & Design Specification are in Yoke: SA-515 Gr70 accordance with ASME BPVC Section lll, Subsection U-Bolt SA-193 87 NF 2007 Edition and are on file at: Nuts: SA-194 2H Pin: 3A-564 TYP 630 Bergen Power Ptpe Supports,lnc. Studs: N/A Product Engineering DePartment Exempt Cotters, Washers, Retainers, Shims (NF-2121) REVISIONS *-rfu K,&& $F/rt Vo/zt /ct? lslGNED /il ) Orioinal lssue 10/27109 l/4\ A /i --_1, BERGEN POWER PIPE SUPPORTS, INC, A SHEET 1 0F 1 REV. A PART NO. 6175.130 jJ- ,rl I, CDRS CATALOG INFORMATION SHEET 4 -/ YOKE CLAMP RESIRII'NT . PART NUMBER 6175.130K *Q PIPE SIZE c D E 14 20 4 19 2 P FT.LBS 1t16 2112 835 T I I 16 22314 4 20 2 1t16 21t2 835 18 25 4 21 2 1t16 2112 835 27 4 23 21t2 835 I 31 4 25 2 1t16 2 1116 835 8 30 37 4 29 2 1t16 36 43 4 32 2 1116 21t2 21t2 21t2 20 24 * t I 835 I 835 I 1,) All dimensions are in inches. 2.) Dimensions are provided for user application only' 3.)This Clamp is compatible with B-P Parts 2250,2252,2421and2440. 4,) Torque Q toleran ca = +l' 10o/o ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size' EXAMPLE: 6175-130-R/0-20" REVISIONS /N I Orioinal lssue / 1\ l) 10127 109 /i /A /s\ BERGEN POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV. A PART N0. 6175-130 jJ- ,TJ CERTIFIED DESIGN REPORT SUMMARY *J, for d NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CUMP for SIRUIS by P.S.C. - PART NUMBER 6202-,35k DIRECTION OF LOADING I I I I I t Nott' Design Spec. No. D$6202 Design Report No. DR-6202 Size Temperature: For, the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Condition Level A Operating Conditions Level B Level C Level D Test Condition (see Note) 350 350 466 525 658 466 I 350 350 466 525 658 466 1114 1112 350 350 466 525 658 466 350 350 466 525 658 466 2 350 350 466 525 658 466 21t2 350 350 466 525 658 466 31,4 6500F 3 350 350 466 525 658 466 4 350 350 466 525 658 466 5 350 350 466 525 658 466 6 350 350 466 525 658 466 8 350 350 466 525 658 466 10 350 350 466 525 658 466 Rated Loads (lbs) for C/asses 1,2,3 & MC * I certify this CDRS Use only with mechanicalstruts manufactured by Pacific Scientific Co. per Bulletin PSA4 6202 CONTROL REF NO. mmplies with he MATERIALS rcquirements of the applicabh code >late: 3A-36 Solts: SA-307 Gr B The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Nuts: 5A-563 GrA Pin: 5A-564 TYP 630 Bergen Power Pipe Supports, lnc. Studs: SA-36 Product Engineering Department Eiempt Cotter pins, Washers, Retainers (NF-2121) REV|SIONS 8,9tk 14,46. 5E L Vo/zt/o? lslGNED /; Orioinal lssue 1 0/27109 I /^ BERGEAJ POWER PIPE SUPPORTS, INC. /t\ /r\ /i SHEET 1 0F I REV. A PART N0. 6202..35 CDRS CATALOG INFORMATION SHEET ptPE 1LAMP for SIRUIS by P,S.C, - PART NUMBER 6202-,35k 10' _l I STOCK PIPE SIZE D E u P S 3t4 5/8 41t4 13t32 3/8 1 5/8 114 1 5/8 4112 13t32 3/8 1718 11//4 1112 5/8 43t4 13t32 3t8 114x1112 114x1112 5/8 4314 13132 3/8 21t8 21t4 2 TxW x1 112 114 x1 112 2 5/8 5 13t32 3/8 2112 5/8 5 314 13t32 3/8 2718 114x1112 114x1112 3 5/8 6 13t32 3/8 3114 114 3/8 3314 4 3t8 114x1112 114x1112 114x1112 9116 x1 4 5/8 7 13t32 5 5/8 71t2 13t32 3/8 6 5/8 8 13t32 3/8 4718 I 5/8 91t2 13t32 3/8 57t8 114 10 5/8 11 13t32 3/8 7 114 1.) All dimensions are in inches' 118 112 x2 x2 : 2.) Dimensions are provided for user application only' 3,)This Clamp is compatible with PSA 1/4' place. 4,) lnstallation: Tension bolts to remove slack, plus 1/2 turn of nut, then lock in ORDERING INSTRUCTIONS: specify: Part Number, oDRS Revision Number, and Pipe size. D(AMPLE: 6202-.35-R/04" ioinal lssue 10127109 BERG EN POWER PIPE SUPPORTS, INC, PART N0. 6202-.35 lit f' CERTIFIED DESIGN REPORT SUMMARY for d b NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CIAIIIP for SIRUIS by P,S.C, - PART NUMBER 6202-,65k DIRECTION OF LOADING I I I I i Nott' Design Spec. No. D$6202 Design Report No. PR-6202 Temperature: 6sooF For, the test condition (Hydro)the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Operating Gonditions Level B Level C Size Design Condition 314 650 650 865 1 650 650 11t4 650 650 Level A Test Gondition Level D (see Note) 975 1,221 865 865 975 1,221 865 865 975 1,221 865 11//2 650 650 865 975 1,221 865 2 650 650 865 9i5 1,221 865 21t2 6s0 650 865 975 1,221 865 9i5 1,221 865 3 650 650 865 4 650 650 865 975 1,221 865 5 650 650 865 975 1,221 865 6 650 650 865 975 1,221 865 I 650 650 865 975 1,221 865 10 650 650 865 975 1,221 865 Ratedloads (lbs)for Classes 1,2,3 &MC * Use only with mechanicalstruts manufactured by Pacific Scientific Co. per Bulletin PSA4 CONTROLREFNO. I certify this CDRS complies with the requirements of the applicable code MATERIALS Plate: SA-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A 6202 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 54-564 TYP 630 Bergen Power Pipe Supports,lnc. Studs: SA-36 Product Engineering Department Exempt Cotter pins, Washers, Retainers (NF-2121) REVISIONS 8.ti*/,&fr, sEAt lta/92/a9lslGNED /l Orioinal lssue 10/27109 /t\ /il /i /^ /5\ BERGEAJ POWERPIPE SUPPORTS, NC, SHEET 1. OF 1 REV. A PART N0. 6202..65 CDRS CATALOG INFORMATION SHEET P|PE CLAMP for STRIIIS by P.S.C. ' PART NUMBER 6202'.65k 10" G-:r Ih-,ru ilrl ]' u PIPE SIZE D E 3t4 5/8 41t4 13t32 STOCK P s 3/8 1 5/8 114x1112 TxW x1 112 112 2718 x1 114 x 1 114 x I 114 x I 3114 114 112 3 3t4 x1 114 x1 3/8 4 318 114 112 13t32 3/8 9112 13t32 3/8 47t8 57t8 x1 114 x 1 11 13132 3/8 7 1t8 1 5/8 4112 13t32 3/8 1718 114 1tt4 5t8 4314 13132 3/8 114 1112 5/8 43t4 13t32 3i8 21t8 21t4 2 5/8 5 13132 3i8 2 9116 2112 5/8 5 314 13t32 3/8 6 13t32 3/8 5/8 7 13132 3/8 5 5/8 7112 13t32 6 5/8 I I 5/8 10 5/8 3 4 5/8 112 112 112 112 112 x2 114 x2 114 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only. 3,)This Clamp is compatible with PSA 1/2' 4.) lnstallation: Tension bolts to remove slack, plus ll2turn of nut, then lock in place' ORDERING INSTRUCTIONS: specify: Part Number, CDRS Revision Number, and Pipe size. E)(AMPLE: 6202-.65-R/04" REVISIONS inal lssue 10127109 BERGE'\' POWER PIPE SUPPORTS, INC, SHEET 1 OF 1 PART N0. 6202..65 tit CERTIFIED DESIGN REPORT SUMMARY for ,, d b NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CLAMP for SIRUIASSEMBT,ES - PART NUMBER 6202-,7k DIRECTION OF LOADING Temperature: No"' Design Spec. No, D96202 Design Report No. DR-6202 6500F For" the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Test Condition Operatins Conditions Level C Level B Size Design Condition 3t4 750 750 998 1 750 750 1114 750 1112 Level D {see Note} 1,125 1,409 998 998 1,125 1,409 998 750 998 1,125 1,409 998 750 750 998 1.125 1,409 998 2 750 750 998 1,125 1,409 998 21//2 750 750 998 1,125 1,409 998 3 750 750 998 1,125 1,409 998 4 750 750 998 998 5 750 750 998 ,125 1.125 1,409 1,409 998 6 750 750 998 1,125 1,409 998 8 750 750 998 1,125 1.409 998 10 750 750 998 1,125 1,409 998 Level A Rated Loads (lbs) for C/asses 1,2,3 &MC I certify this CDRS complies with CONTROL REF NO. he MATERIALS requirements of the applicable code Plate: 5A-36 Bolts: SA-307 Gr B Nuts: 54-563 Gr A Pin: 5A-564 TYP 630 6202 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Bergen Power Pipe Supports, lnc. Studs: SA-36 Product Engineering Department Exempt Cotter pins, Washers, Retainers (NF-2121) REV|S|ONS e'4t>K,&..6, sEAr- lta/az/a / ISIGNED /o\ Oriqinal lssue 1 0/27109 /i 1 /r\ 2 /c BERGEN POWER PIPE SUPPORTS, INC, sHEETloFl I nev. A PART N0. 6202..7 CDRS CATALOG INFORMATION SHEET PIPE CLAMP fOT SIRUTASSEMBT'ES PIPE SIZE 3t4 1 1114 NOTES: ' E 5/8 41t4 5/8 4112 5/8 4 3t4 4 3t4 PART NUMBER 6202-.7K STOCK P s 17t32 3/8 1 5/8 114 3/8 17t8 114 112 17t32 3/8 2118 x1 x1 114 x1 112 17t32 17t32 3/8 21t4 114x1112 tt D . TxW 112 11t2 5/8 2 5/8 5 17t32 3/8 2 9t16 114 21112 5/B 17t32 3/8 2718 114 112 3 5/8 6 17t32 3/8 3114 4 5/8 7 17t32 3/8 33t4 x1 x1 114 x1 114 x1 112 5 3t4 5 5/8 71t2 17t32 3/8 4 3t8 114 x1 112 6 5/8 17t32 3/8 x1 112 5/8 9112 17t32 3/8 47t8 57t8 114 I I 10 5/8 11 17t32 3/8 7 1t8 112 112 114x2 114xZ L ) All dimensions are in inches. 2.) Dimensions are provided for user application only' 3.)This Clamp is compatible with B-P Pads 2015,2250,2252,2440 and2420' 4.) lnstallation: Tension bolts to remove slack, plus ll2lurn of nut, then lock in place. ORDERING INSTRUCTIONS : Specify: Part Number, CDRS Revision Number, and Pipe Size. EMMPLE: 6202'J'N04' REVISIONS BERGEN POWER PIPE SUPPORTS, INC. PART N0, 6202..7 titJ' CERTIFIED DESIGN REPORT SUMMARY for d b NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CUMP for SIRUI ASSEMBTTES - PART NUMBER 6202'1.sk DIRECTION OF LOADING I Temperature: no"' Design Spec. No. DS-6202 Design Repoil No, DR-6202 Size Fo, the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition, Design Condition Level A Test Gondition Operating Gonditions Level C Level B Level D (see Note) 1,500 1,500 1,995 2,250 2,819 1,995 1 1,500 1,500 1,995 2,250 2,819 1,995 11t4 1,500 1,500 1.995 2,250 2,819 1,995 1,500 1,500 1,995 2,250 2,819 1,995 1,500 1,500 1,995 2,250 2,819 1,995 21t2 1,500 1,500 1,995 2,250 2,819 1,995 3 1,500 1,500 1.995 2,250 2,919 1,995 4 1,500 1,500 1.995 2,250 2,819 1.995 5 1,500 1,500 1.995 2,250 2,819 1,995 6 1,500 1,500 1,995 2,250 2,819 1,995 I 1,500 1,500 1,995 2,250 2.819 1,995 10 1,500 1,500 1,995 2,250 2,819 1,995 12 1,500 1,500 1,995 2,250 2,819 1,995 314 1112 2 650'F Rated Loads (lbs) for C/asses 1,2,3 &MC I 6202 CONTROL REF NO. certifl this CDRS complies with the MATERIALS requiremenb ol the applicable code Plate: 3A-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 5A-564 TYP 630 Bergen Power Pipe SupPorts, Inc. Studs: SA-36 Product Engineering DePartment Exempt Cotter pins, Washers, Retainers (NF-2121) REVISIONS /r-.>,&,il*fr#.AL Va/zzlot /i 0riqinal lssue 1 0/27109 lslGNED /z\ BERGEA' POWERPIPE SUPPORTS, INC. /3\ /t /s\ SHEET 1 0F 1 REv. a PART N0. 6202.1.5 CDRS CATALOG INFORMATION SHEET P|PE CLAMP for STRTJIASSEMBLTES ' PART NUMBER 6202'1,5k PIPE SIZE D E st ^* 3t4 P s 21t32 21t32 1t2 17t8 21t8 23t8 25t8 STOCK TxW x2 x2 114 x2 114 x2 1 3t4 41t4 41t2 1114 1112 314 4314 21132 1t2 3t4 4314 21132 1t2 2 3t4 5 21t32 1t2 3 3t4 5314 21t32 1t2 31t4 114 6 21t32 1t2 31t2 114x2 7 21132 1t2 4114 3lB 112 21t32 1t2 413116 3ii4 2112 1t2 114 114 114x2 x2 3 314 4 3t4 5 3t4 6 314 I 21132 1t2 s 3/8 I 3t4 9112 21t32 1t2 6 3/8 10 3t4 11 21t32 1t2 7 318 318x2 318x2 318x2 318x2 12 3t4 12 21132 1t2 8 5/8 112x2 7 x2 NOTES: 1.) All dimensions are in inches' 2.) Dimensions are provided for user application only' 3.)This Clamp is compatible with B-P Parts 2015,2250,2252,2440 and2420. place. 4.) lnstallation: Tension bolts to remove slack, plus ll2lurn of nut, then lock in * 5.) G = 112", when used with PSA-1' ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, Pipe Size and "G" Dimension' EMMPLE: 6202-1.5-R/04' G= 21132" ioinal lssue 10127109 BERG EN POWER PIPE SUPPORIS, INC. SHEET 1 OF 1 PART N0. 6202-1.5 tit f' CERTIFIED DESIGN REPORT SUMMARY for * b NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CUMP for SIRUTASSEMBT,ES . PART NUMBER 6202-4k DIRECTION OF I LOADING Temperature: Nottt Design Spec. No. DS-6202 Design Report No. DR-6202 Fol, the test condition (Hydro)the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Test Condition Operating Gonditions Level C Level B Size Design Condition 2112 4,000 4,000 5,320 3 4,000 4,000 4 4,000 5 Level D (see Note) 6,000 7,516 5,320 5,320 6,000 7,516 5,320 4,000 5,320 6,000 7,516 5,320 4,000 4,000 5,320 6,000 7,516 5,320 6 4,000 4,000 5,320 6,000 7,516 5,320 E 4,000 4,000 5,320 6,000 7,516 5,320 5,320 Level A 4,000 5,320 6,000 7,516 4,000 4,000 5,320 6,000 7,516 5,320 14 4,000 4,000 5,320 6,000 7,516 5,320 16 4,000 4,000 5,320 6,000 7,516 5,320 18 4,000 4,000 5,320 6,000 7,516 5,320 20 4,000 4,000 5,320 6,000 7,516 5,320 24 4,000 4,000 5.320 6,000 7,516 5,320 30 4,000 4,000 5,320 6,000 7,516 5,320 36 4,000 4,000 5,320 6,000 7,516 5,320 10 12 6500F 4,000 Rated Loads ilb$ for Classes 1,2,3 &MC CONTROLREFNO. I certify this CDRS complies with the MATERIALS rcquirements of the applicable code Plate: 5A-36 Bolts: SA-307 Gr B Nuts: 5A-563 GrA 6202 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 3A-564 TYP 630 Bergen Power Pipe SuPqorts,lnc. Studs: SA-36 Product Engineering DePartment Exempt Cottei pins, Washers, Retainers (NF-2121) REVIStONS futuK,aur,a SEAL I ISIGNED /; Orioinal lssue 10/27109 /3\ A /A /z\ /s\ BERGEN POWER PIPE SUPPORTS, INC. SHEET 1 0F I REV. A PART N0. 6202-4 tijT, CDRS CATALOG INFORMATION SHEET d E PIPE CIAMP fOr SIRUIASSEMBT'ES . PART NUMBER 6202.4K IG; L---_l I D PIPE SIZE D E G 2112 71t4 21t32 1t2 7 3t4 21t32 4 7t8 7t8 7t8 81t4 5 718 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 3 6 I 10 12 14 16 18 20 24 30 36 P s STOCK TxW 518 x2-112 1t2 41t4 41t2 518 x2-112 21t32 1t2 5 1/8 518x2-112 8314 21t32 1t2 53t4 6 3/8 7 3t8 91t2 zil32 1t2 101t2 21t32 1t2 12 21t32 1t2 81t2 13 21t32 1t2 9718 14 21132 1t2 10 5/8 15 21t32 1t2 11518 5/8x3 5/8x3 5/8x4 518 x4 5/8x5 314 x4 314 x4 16 21t32 1t2 125t8 314x4-112 17 21t32 1t2 13 19 21t32 1t2 16118 23 21t32 1t2 19114 1x4-112 1x4-112 26 21t32 1t2 22114 1x5 314 3/4x5 NOTES: 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only' 3.)This Clamp is compatible with B-P Parts 2015,2250,2252,2525 and 2530' 4.) lnstallation: Tension bolts to remove slack, plus 1/2 turn of nut, then lock in place. ORDERING INSTRUCTIONS: specify: Part Number, CDRS Revision Number, and Pipe size, DGMPLE: 6202-4-R/04" REVISIONs Albrtqrnal tssue t OlZZlOg /s\ /1' /A /r\ /N BERG EN POWER PIPE SUPPORTS, INC, SHEET L 0F l- REV. A PARr N0. 6202-4 tit r, CERTIFIED DESIGN REPORT SUMMARY for d E NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CUMP for SIRUIS by P.S,C. - PART NUMBER 6202-6k DIRECTION OF LOADING Temperature: V Nott' Design Spec. No. DS-6202 Design Repoil No. DR-6202 6500F For' the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Size Design Condition Level A OperatinE Gonditions Level B Level C Level 0 Test Condition (see f.lotel 3 6,000 6,000 7,980 9,000 11,274 7,980 4 6,000 6,000 7,980 9.000 11.274 7,980 5 6,000 6,000 7.980 9,000 11,274 7.980 6 6,000 6,000 7,990 9.000 11.274 7.980 E 6,000 6,000 7,990 9,000 11,274 7,980 10 6.000 6,000 7,980 9,000 11,274 7,980 12 6,000 6.000 7,980 9,000 11,274 7,980 14 6,000 6,000 7,980 9,000 11,274 7,980 9,000 11,274 7,980 16 6,000 6,000 7,980 18 6,000 6,000 7,980 9,000 11,274 7,980 7,980 20 6,000 6,000 7,980 9,000 11,274 24 6,000 6,000 7,980 9,000 11,274 7,980 30 6,000 6.000 7,980 9,000 11,274 7,980 36 b,000 6,000 7,980 9,000 11,274 7,980 Rated Loads (lbs)for C/asses 1,2,3 &MC * Use only with mechanical struts manufactured by Pacific Scientific Co. per Bulletin PSA4 CONTROLREFNO. I certify this CDRS complies with the requhements of tte applicable code [IATERIALS 6202 The Design Report & Design Specification are in Plate: 34-36 Bolts: SA-307 Gr B Nuts: 5A-563 GrA Pin: 5A-564 WP 630 Studs: 34-36 accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Bergen Power Pipe Supporfg lnc. Product Engineering Depailment Exempt Cotter pins, Washers, Retainers (NF-2121) REVISIONS AlOriginal E-i-"K,&.ffi AI#,nr l/a/zz/as lslGNED /) lssue 10/27109 7, BERGETV POWER PIPE SUPPORTS, ll/J i t, J NC. SHEET 1 0F 1 REV. A PARTN0. 6202.6 CDRS CATALOG INFORMATION SHEET P|PE CLAMP for SIRUIS by P.S.C' ' PART NUMBER 6202-6k 10' c-]l ffi, W STOCK PIPE SIZE 3 4 D 11t8 1 1t8 E 7 314 G 13132 P S 314 4112 518 x2-112 518 x2-112 8114 13t32 314 5 1/8 I314 13t32 3t4 5314 TxW 5/8x3 5/8x3 9112 13t32 314 6 3/8 I 11t8 11t8 11t8 10112 13t32 314 7 318 518x4 10 1118 12 13t32 3t4 8112 12 13 13t32 3t4 g7t8 14 13t32 314 10 5/8 15 13132 3t4 11 5/8 16 13132 3t4 125t8 17 13132 3t4 13 3t4 3/4x5 19 13t32 3t4 161/8 30 11t8 11t8 11t8 11t8 11t8 11t8 11t8 5/8x4 5/8x5 23 13t32 3t4 1x4-112 1x4-112 36 1118 26 13t32 3t4 191t4 221t4 5 6 14 16 t8 20 24 314x4 314x4 314 x4-112 1x5 NOTES: 1.) All dimensions are in inches' 2')Dimensionsareprovidedforuserapplicationonly' 3.)This Clamp is compatible with PSA-3 place. 4.) lnstallation: Tension bolts to remove slack, plus 1l2lum of nut, then lock in ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size' EXAMPLE: 6202-6-R/04- al lssue 10127109 BERGEN POWER PIPE SUPPORTS, INC. tltI' CERTIFIED DESIGN REPORT SUMMARY for ffiJ ry NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CUMP for STRUIASSE?|BLIES - PART NUMBER 6202-7k DIRECTION I OF l I LOADING Temperature: I Nott' Design Spec. No. DS-6202 Fol. the test condition 6500F (Hydro)the maximum temperature is 100"F. For higher temperatures in the Test Condition, use Level B loads up to the temperature Design Report No. DR-6202 shown for the Operating Condition. Size Design Condition 3 0peratino Conditions Test Gondition Level A Level B Level G Level D (see Note) 7,000 7,000 9,310 10,500 13,153 9,310 I 7,000 7,000 9,310 10,500 13,153 9,310 5 7,000 7,000 9.310 10,500 13,153 9,310 6 7,000 7,000 9,310 10,500 13,153 9,310 8 7.000 7,000 9,310 10,500 1 3,1 53 9,310 t0 7,000 7,000 9,310 10,500 13,153 9,310 12 7,000 7,000 9,310 10,500 1 3.1 53 9.310 14 7,000 7,000 9,310 10,500 13,153 9,310 16 7,000 7,000 9,310 10,500 13,153 9,310 18 7,000 7,000 9,310 10,500 13,153 9,310 20 7,000 7,000 9,310 10,500 1 3,1 53 9,310 24 7,000 7,000 9,310 10,500 13,153 9,310 30 7,000 7,000 9,310 10.500 1 3,1 53 9,310 36 7,000 7,000 9,310 10,500 13,153 9.310 Rated Loads (lbs)for Classes 1,2,3 & MC I certify this CDRS CONTROL REF NO. mmplies with $e requirements of the applicable code MATERIALS 6202 The Design Report & Design Specification are Plate: 5A-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 5A-564 TYP 630 Bergen Power Pipe Supports, lnc. Studs: SA-36 Product Engineering Department Exempt Cotter pins, Washers, Retainers (NF-2121) REV|StONS /il t4rbK,d*fr /t\ *.AL lta/qz/dq /s\ lOrioinal lssue $127109 /t /i ISIGNED /z\ BERGETV POWER PIPE SUPPORTS, NC, sHEErl 0F I REV. A PART NO. 6202.7 ti7 T, CDRS CATALOG INFORMATION SHEET FJ E PIPE CLAMP fOr SIRUT ASSEMBI'ES u PIPE SIZE D E 3 1 1t4 7 314 1t4 8114 . P s 3t4 4 3t4 STOCK TxW 3t4 51t4 5/8x5 5/8x5 3t4 6 5/16 718 x4-112 3t4 67t8 718x4-112 3t4 I 718x4-112 5 1 114 8314 6 1 1t4 9112 I 1114 101t2 29t32 29t32 29t32 29t32 29t32 10 1 1t4 12 29132 314 12 1114 13 14 1 1t4 14 29t32 29t32 16 1 114 15 4 PART NUMBER 6202.7K I 5/16 1x5 3t4 10 3/8 1x5 314 111t4 29132 3t4 12114 131t4 1x5 1x5 1x5 1x5 18 1114 16 29132 3t4 20 1114 17 29132 3t4 14114 24 1114 19 29132 3t4 16 3t4 30 1 114 23 29ts2 314 20 1-114 x6 36 1 1t4 26 29t32 3t4 23 1-114 xE 1xO 1.) All dimensions are in inches. 2.) Dimensions are provided for usrir application only' 3.) This Clamp is compatible with B-P Parts 2250,2252,2440 and2420' 4.) lnstallation: Tension bolts to remove slack, plus ll2lurn of nut, then lock in place' ORDERING INSTRUCTIONS: specify: Part Number, 0DRS Revision Number, and Pipe size. DGMPLE: 6202-7-N0-4' REVISIONS /N Oriqinal lssue 1 0/27109 /t\ /a\ /s\ /^ BERG EN POWER PIPE SUPPORTS, INC. SHEET 1 0F 1 REV. A PART N0. 6202-7 J,tJl CERTIFIED DESIGN REPORT SUMMARY r, for d H NUCLEAR POWER PLANT STANDARD SUPPORTS - PART NUMBER 6202-12k PIPE CLAMP for SIRUI ASSEIfBIIES _l DIRECTION OF I LOADING Temperature: Nott' Design Spec. No. DS-6202 Design Report No. DR-6202 For the test condition (Hydro) the maximum temperature is 100oF. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Size Design Condition 3 12,000 Test Condition (see Note) 12,000 15,960 18,000 18.000 22,548 15,960 15,960 4 12,000 12,000 5 12,000 12,000 15,960 18.000 22,548 15,960 6 12,000 12,000 15,960 18,000 22,548 15,960 I 12,000 12,000 15,960 18,000 22,548 15.960 10 12,000 12,000 15,960 18,000 22,548 15,960 12 12,000 12,000 15,960 18,000 22,548 15,960 14 12,000 12,000 15,960 18,000 22,548 15,960 16 12,000 12,000 15,960 18.000 22,548 15,960 18 12,000 12,000 15,960 18,000 22,548 15,960 20 12,000 12,000 15,960 18,000 22,548 15,960 15,960 30 36 12,000 15,960 18,000 22,548 12,000 12,000 15.960 18,000 22,548 15,960 12,000 12,000 15,960 18,000 22,548 15,960 12,000 Rated loads (lbs) for C/asses 1,2,3 &MC CONTROLREFNO. I certify this CDRS complies with the requirements of the apflicable Operating Conditions Level C Level B Level D 22,U8 Level A 15,960 24 6500F ode MATERIALS Plate: 5A-36 Bolts: SA-307 Gr B Nuts: 3A-563 Gr A 6202 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 5A-564 WP 630 Bergen Power Pipe Suppotts,lnc. Studs: SA-36 Product Engineering Department Eiempt Cotter pins, Washers, Retainers (NF-2121) REV|StONS LhK,&.fr, 9EAL Va/z2/oflSlGNED /il Oriqinal lssue 1 0127/09 A /i BERGETI, POWER PIPE SUPPORTS, INC, /^ A /i SHEET 1 0F 1 REV. A PART N0. 6202.12 JJ-, ,lJ r, CDRS CATALOG INFORMATION SHEET #l PIPE CUMP fOT SIRUIASSEMBI.'ES - PART NUMBER 6202.12K I t- D E G P c STOCK PIPE SIZE 3 1114 7 3t4 29t32 3t4 4 3t4 5/Bx5 1114 1t4 81t4 29t32 3t4 51t4 5/8x5 8 3t4 29t32 3t4 6 5/16 718 x4-112 4 NOTES: TxW 5 1 6 1 1t4 9112 29t32 3t4 6718 718 x4-112 29t32 3t4 8 718 x4-112 8 1 1t4 10112 10 1 1t4 12 29t32 3t4 12 1 114 13 29132 3t4 10 3/8 14 1 114 14 29t32 3t4 111t4 16 15 29132 3t4 12114 18 11t4 11t4 16 29t32 314 20 1 1t4 17 29t32 3t4 131t4 141t4 I 24 1 1t4 19 29t32 3t4 16 3/4 30 1 1t4 23 29t32 3t4 20 1x5 1x5 1x5 1x5 1x5 1x5 1x6 1-114 x6 36 1 1t4 26 29t32 3t4 23 1-114 5/16 x6 ' 1,) All dimensions are in inches. . 2.) Dimensions are provided for user application only. 3.) This Clamp is compatible with B-P Parts 2250,2252,2525 and 2530. 4.) lnstallation: Tension bolts to remove slack, plus ll2turn of nut, then lock in place. ORDERING INSTRUCTIONS : Specify: Part Number, CDRS Revision Number, and Pipe Size' D(AMPLE: 6202-12-N04' REVISIONS /N I Oriqinal lssue 10127 109 /i iil /4\ /o\ /5' BERGEN POWER PIPE SUPPORTS, INC, SHEET 1 0F 1 REV. A PART N0. 6202-12 ti| J' CERTIFIED DESIGN REPORT SUMMARY for d k NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CLAMP for SIRUIS by P.S.C. - PART NUMBER 6202'15k DIRECTION OF LOADING I Temperature: Nott' Design Spec. t{o. D96202 Design Report No. DR-6202 For the test condition (Hydro) the maxirnum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Size Design Condition 3 Test Condition Operating Conditions (see Note) Level A Level B Level C Level 15,000 15,000 19,950 22,500 28,185 19,950 4 15,000 15,000 19,950 22,500 28,185 19,950 5 15,000 15,000 19,950 22,500 28,185 19,950 6 15,000 15,000 19,950 22,500 28,185 19,950 8 15,000 15,000 19.950 22,500 28,185 19,950 10 15,000 15,000 19,950 22,500 28,185 19,950 15,000 19,950 22,500 28,185 19,950 15,000 15,000 19,950 22,500 28,185 19,950 15,000 15,000 19,950 22,500 28,185 19,950 19.950 22,500 28,185 19,950 15,000 12 14 16 6500F D 18 15,000 15,000 20 15,000 15,000 19,950 22,5A0 28,185 19,950 24 15,000 15.000 19,950 22,500 28,185 19,950 30 15,000 15,000 19,950 22,540 28,185 19,950 36 15,000 15,000 19,950 22,500 28,185 19,950 Rated Loads (lhs) for C/asses 1,2,3 & MC * Use only with mechanical struts manufactured by Pacific Scientific Co. per Bulletin PSA4 CONTROLREFNO. I certify this CDRS complies with the MATERIALS requirements ol the appfrcable code Plate: 5A-36 Bolts: SA-307 Gr B Nuts: 5A-563 GrA 6202 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: S4-564 TYP 630 Bergen Power Pipe SuPPorts,lnc. Studs: SA-36 Product Engineering DePartment Exempt Cotter pins, Washers, Retainers (NF-2121) REVISI0NS &->,tr,U"fr SEAL lz/zz/a9 ISIGNED /N 0riqinal lssue 10/27109 it A 4\ /^ /s\ BERGEAJ POWER PIPE SUPPORTS, INC. SHEET 1 0F I REv. a PART N0, 6202.15 CDRS CATALOG INFORMATION SHEET ptPE 1LAMP for SIRUIS by P.S.C. - PART NUMBER 6202-15k E D PIPE SIZE 11t4 11t4 7 314 4 5 1114 8 3/4 6 1 114 91t2 8 1 1t4 10112 10 11t4 12 12 1 1t4 13 14 1114 14 16 1 1t4 15 18 1114 16 20 11t4 11t4 11t4 11t4 17 3 24 30 36 8114 19 23 26 STOCK t, P S 1 3132 1 3132 1 3t32 1 3132 1 3132 1 3t32 1 3t32 1 3132 1 3132 1 3132 1 3t32 1 3132 1 3t32 1 3t32 I 5 1/8 5114 1 1 6 5/16 TxW 5/8x5 5/8x 5 718 x4-112 1 6718 718 x4-112 1 8 718 x4-112 1 I 5/16 1 10 3/8 1 11114 1 12114 1 13114 1 14114 1 16 314 1x5 1x5 1x5 1x5 1x5 1x5 1x6 1 20 1-114 1 23 1-114 x6 x6 1.)Alldimensions are in inches' 2.) Dimensions are provided for user application only' 3,)This Clamp is compatible with PSA-10 in place. 4.) lnstallation: Tension bolts to remove slack, plus 1/2 turn of nut, then lock ORDERING INSTRUCTIONS: specify: Part Number, 0DRS Revision Number, and Pipe size. DGMPLE: 62a2-15-R/04" BERGEN POWER PIPE SUPPORTS, INC. PART N0. 62A245 titr, CERTIFIED DESIGN REPORT SUMMARY for d Y NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CLAMP for SIRUTASSEMBTTES 'l * I ----'t'---- - PART NUMBER 6202'25k DIRECTION - OF I LOADING t No"' Design Spec. No. DS-6202 Design Report No. DR-6202 Temperature: For. the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition, Operating Gonditions Level C Level B Size Design Condition 4 25,000 25,000 33,250 5 25,000 25,000 33,250 6 25,000 25,000 33,250 I 25,000 25,000 33,250 Level A Test Gondition Level D (see Note) 37,500 46,975 33,250 37,500 46,975 33,250 37,500 46,975 33,250 37,500 46,975 33,250 33,250 33,250 25,000 33.250 37,500 46,975 25,000 25,000 33.250 37,500 46,975 14 25,000 25,000 33,250 37,500 46,975 33,250 16 25,000 25,000 33,250 37,500 46,975 33,250 10 12 25,000 18 25,000 25,000 33,250 37,500 46,975 33,250 2g 25,000 25,000 33,250 37,500 46.975 33,250 24 25,000 25,000 33,250 37,500 46,975 33,250 30 25,000 25,000 33,250 37,500 46,975 33,250 36 25,000 46,975 33,250 I certify this CDRS oomplies with the 37.500 33,250 25,000 Rated Loads (lbs) for Classes 1,2,3 &MC CONTROL REF NO. MATERIALS requircments of ths applicable code 6500F Plate: 3A-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A Pin: S4-564 WP 630 Studs: SA-36 Exempt Cotter pins, Washers, Retainers (NF-2121) 6202 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Bergen Power Pipe SuPPods, lnc. Product Engineering DePartment REVISIONS tt:,* 4,&.#' Stet lra/zz/ol lslGNED /o\ Oriqinal lssue 10/27109 A /^ BERGET'J POWER PIPE SUPPORTS, INC, /i 4\ /n SHEET L OF l- REV. A PART N0, 6202.25 CDRS CATALOG INFORMATION SHEET PIPE CUMP fOr STRIJIASSEMBT'ES . PART NUMBER PIPE SIZE D 4 2114 91t4 5 2114 10 6 8 21t4 21t4 11 10 2114 131t2 12 21t4 14112 14 2114 16 16 17 18 21t4 21t4 20 2114 19 24 2114 22 30 36 21t4 2114 l|:| E 12 18 25 28 1 7116 1 7t16 I 1 I 7t16 7t16 7t16 7t16 1 1 7116 1 7t16 1 7116 1 7t16 1 7t16 1 7116 1 7116 6202-25K STOCK P D 1 7 1 7 3t4 1-114 1 8 3/8 1-114 I 1-114 1 TiW 1-114x5 5/8 x5 x5 x5 x5 x5 1 10 3t4 1-114 1 11718 1-114 1 131t8 1 14118 1-112x5 1-112x5 1-112x6 1-112x6 1 151t4 1 16 3/8 1 183t4 1-314 x5 1 22 1^314 I 251t8 1-314 x5 x7 NOTES: 1.) All dimensions are in inches. ' 2.) Dimensions are provided for user application 2530' 2525 and 2420,2440, 2250,2252, Parts B-P 3.) This Ctamp is compatible with place' 4.) lnstallation: Tension bolts to remove slack, plus ll2lurn of nut, then lock in only' ORDERING INSTRUCTIONS : Specify: Part Number, CDRS Revision Number, and Pipe Size. DGMPLE: 6202-25-N04', inallssue 10127109 BERG EN POWER PIPE SUPPORTS, INC, SHEET 1 0F 1 PART N0. 6202-25 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CUMP for STRUIASSEMBTTES - PART NUMBER 6202-35k DIRECTION OF LOADING Temperature: *ott' Design Spec. No. D96202 Design Report No. DR-6202 6500F For" the test condition (Hydro)the maximum temperature is 100oF. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Size Design Condition Level A Operatins Conditions Level C Level B Level D Test Gondition (see Note) I 35,000 35,000 46,550 52,500 65,765 46,550 10 35,000 35,000 46,550 52,500 65,765 46,550 12 35,000 35,000 46,550 52,500 65,765 46,550 35,000 46,550 52,500 65,765 46,550 35,000 35,000 46,550 52,500 65,765 46,550 46,550 52,500 65,765 46,550 14 l6 35,000 18 35,000 35,000 20 35,000 35,000 46,550 52,500 65,765 46,550 24 35,000 35,000 46,550 52,500 65,765 46,550 30 35,000 35,000 46,550 52,500 65,765 46,550 36 35,000 35,000 46,550 52,500 65,765 46,550 Rated Loads (lbs) for Classes 1,2,3 &MC I cortify this CDRS complies with CONTROL REF NO. he MATERIALS r€quirements of the applcable code 6202 The Design Report & Design Specification are in Plate: 5A-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 5A-564 TYP 630 Bergen Power Pipe Suppodg lnc. Studs: SA-36 Product Engineering Department Exempt Cotter pins, Washers, Retainers (NF-21 21) REV|SIONS t*>K,&,.fr SFAL lta/Zz,/a? ISIGNED /dr I Oriqinal lssue 1 0/27109 J /.r\ /^ BERGEN POWER PIPE SUPPORTS, INC. -L i /r\ i SHEET 1 0F 1 REV. A PART NO. 6202.35 CDRS CATALOG INFORMATION SHEET PIPE CLAMP fOT SIRUTASSEMBT'ES . PART NUMBER 6202'35K STOCK E G P S 2518 12 11t4 10 2518 13112 117t32 117t32 101t4 113t4 12 2518 141t2 117132 14 2518 16 117132 133t4 1-112xB 16 25t8 17 117132 11t4 11t4 11t4 14 3t4 1-112x6 PIPE SIZE 8 D 1114 TxW 1-114 x6 1-112x5 1-112x5 12718 18 25t8 18 117132 1 1t4 157t8 1-112x7 20 2518 19 117t32 1 1t4 17 1-112x7 24 22 117132 1 114 191t2 1-314 x6 30 2 518 2 518 25 1 1t4 22518 1-314 xT 36 25t8 28 117t32 117t32 1 25 5t8 1-314x8 114 1.) All dimensions are in inches. 2.) Dimensions are provided for user applbation only' 3.)This Clamp is compatible with B-P Parts 2250,2252,2525 and 2530. place' 4.) lnstallation: Tension bolts to remove slack, plus ll2lurnof nut, then lock in ORDERING INSTRUGTIONS : Specify: Part Number, CDRS Revision Number, and Pipe Size. DGMPLE: 6202-35-R/0-16" inallssue 10127109 BERGETV POWER PIPE SUPPORTS, INC. SHEET 1 0F 1 tir r, CERTIFIED DESIGN REPORT SUMMARY for d b NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CUMP for STRUIASSEII4BL,ES - PART NUMBER 6202-50k b @@ DIRECTION OF LOADING + o@ Nott' Design Spec. No. D96202 Design Report No. DR-6202 I I I 1 Temperature: 6500F For the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Level D Test Gondition (see Note) 75,000 93,950 66,500 75,000 93,950 66.500 75,000 93,950 66.500 66,500 75,000 93,950 66,500 50,000 66,500 75,000 93,950 66,500 50,000 50,000 66,500 75,000 93,950 66,500 66,500 Operating Gonditions Level B Level C Size Design Condition 10 50,000 50,000 66.500 12 50,000 50,000 66,500 14 50,000 50,000 66,500 16 50,000 50,000 18 50,000 20 Level A 24 50,000 50,000 66.500 75,000 93,950 30 50,000 50,000 66,500 75,000 93.950 66,500 36 50,000 50,000 66,500 75,000 93.950 66,500 Rated Loads (lbs) for C/asses 1,2,3 & MC * I Two bolt configuration is for Pipe Size 10 Only. CONTROLREFNO. certfy this CDRS complies with $e requirements of the applicatrle code MATERIALS Plate: 5A-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A 6202 The Design Repoil & Design Specification are in accodance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: SA-564 TYP 630 Bergen Power Prpe Supporls,lnc. Studs: SA-36 Product Engineering Department Exempt Cotter pins, Washers, Retainers (NF-2121) REV|S|ONS /t\ /t\ /t\ lslGNED /z\ /J e4-htr,d'fr $EAL l/dh?/ot /t Orioinal lssue 10/27109 BERGE,\J POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV. A PARTNO. 6202-50 CDRS CATALOG INFORMATION SHEET PIPE CUMP fOr SIRUIASSEMBT'ES . PART NUMBER 6202.50K 10' r'il[ b oo E I t_ I I I : S .,4t919 -,4. PIPE SIZE D STOCK E t(t P s 141t4 11t2 11t2 101t4 113t4 1-112x6 TxW {0 2114 12 2114 15114 13t4 13t4 14 21t4 16314 1314 1112 127t8 1-112 16 2114 17 314 13t4 11t2 13314 1-112x7 18 2114 18 314 1314 1112 143t4 1-314 20 193t4 1314 1112 15718 1-314x7 22314 19112 1-314 36 2114 283t4 1314 11t2 11t2 11t2 1-3i4 x 8 2s314 13t4 13t4 17 30 21t4 21t4 21t4 225t8 1-314x10 24 1-112x7 x7 x7 x9 NOTES: * 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only. 3.) This Clamp is compatible with PSA-35 and B-P Parls 2440,2525 and 2530' 4.) lnstallation: Tension bolts to remove slack, plus ll2turn of nut, then lock in place, 5.) Two bolt configuration is for Pipe Size 10 Only' ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size' DGMPLE: 6202-50-R/0-16" REVISIONS inal lssue 10127109 BERGEAJ POWER PIPE SUPPORTS, INC, PART N0. 6202.50 tit f' CERTIFIED DESIGN REPORT SUMMARY for d b NUCLEAR POWER PLANT STANDARD SUPPORTS PI PE CLAMP for SIRUI A SSE ItBt,ES - PART NU MBER 6202-60k b oo DIRECTION OF LOADING I @@ no"' Design Spec. No. DS-6202 Design Repoft No. DR-6202 Size Temperature: 6500F Fo, the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Condition Level A Operatins Conditions Level B Level C Level D Test Condition (see Note) 10 60,000 60,000 79,800 90,000 112.740 79,800 12 60,000 60,000 79,800 90,000 112,740 79,800 14 60,000 60.000 79,800 90,000 112,740 79,800 16 60,000 60,000 79,800 90,000 112,740 79,800 79,800 90,000 112,740 79,800 18 60,000 60,000 20 60,000 60,000 79,800 90,000 112.740 79,800 24 60,000 60,000 79,800 90,000 112,740 79,800 30 60,000 60,000 79,800 90,000 112,740 79,800 36 60,000 60,000 79,800 90,000 112,740 79,800 Rated Loads (lbs) for C/asses 1,2,3 &MC * Two bolt configuration is for Pipe Size 10 Only. I certify CONTROLREFNO. this CDRS complies with lhe rcquirements of the applicable code MATERIALS Plate: 3A-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A 6202 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 3A-564 TYP 630 Bergen Power Pipe Supports, lnc. Studs: 3A-36 Product Engineering Department xempt Cotter pins, Washers, Retainers (NF-2121) REVtStONS A*'tu/,(%,fr' SEAL 176/22/a9 /o\ Oriqinal lssue 10/27109 ZT ISIGNED /z\ BERGEfV POWERPIPE SUPPORTS, INC. /i /t /) SHEET 1 OF I REV. A PART N0, 6202,60 litr, CDRS CATALOG INFORMATION SHEET nl PIPE CLAMP for SIRUIASSEMBTTES - PART NUMBER 6202'60k 10' 1,tr b 4HFJ' L oo _l I o@ PIPE SIZE D t E P s STOCK TxW 10 21t4 141t8 1314 1112 11 1t2 1-3/4 x 6 12 21t4 15114 14 13112 1-314 x7 x7 16 21t4 21t4 17 314 11t2 11t2 11t2 1-314 16 3t4 13t4 13t4 13t4 125t8 2114 14 9/16 1-314 xT 18 3t4 1314 1112 16 1t16 21t4 19 3t4 21t4 223t4 13t4 13t4 13t4 13t4 18 20 24 30 36 21t4 21t4 2s3t4 283t4 11t2 2x7 2x7 2xB 17 1t8 19 1112 11t2 11t2 7116 22112 2x9 25 5t8 2x10 NOTES: 1.) All dimensions are in inches. 2,) Dimensions are provided for user application only. 3,)This Clamp is compatible with B-P Parts 2250,2252,2421,2440,2525 and2530. 4.) lnstallation: Tension bolts to remove slack, plus ll2turn of nut, then lock in place. * 5.)Two bolt configuration ORDERING INSTRUCTIONS is for Pipe Size 10 Only. : Specify: Part Number, CDRS Revision Number, and Pipe Size. EXAMPLE: 6202-60-R/0-16" REVISIONS /o\ Oriqinal lssue 1 0/27109 /s\ /4' /2' /i BERG EN POWER PIPE SUPPORTS, INC. SHEET 1 0F 1 REV. A PART N0. 6202.60 titL CERTIFIED DESIGN REPORT SUMMARY for * H NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CUMP Ior STRUTASSE,I'BIIES . PART NUMBER 6202.80K b e@ DIRECTION OF LOADING Temperature: No*t' Design Spec. No. D$6202 Design Report No. DR-6202 6500F Fo, the test condition (Hydro)the maximum temperature is 1000F, For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition, Size Design Condition Level A Operatino Conditions Level C Level B Level D Test Condition (see Note) 10 80,000 80,000 106,400 120,000 150,320 106,400 12 80,000 80,000 106,400 120,000 150,320 106,400 14 90,000 90,000 106,400 120,000 150,320 106.400 16 80,000 80,000 106,400 120,000 150,320 106,400 18 80,000 80,000 106,400 120,000 150,320 106,400 20 80,000 80,000 106,400 120,000 150,320 106,400 24 80.000 80,000 106,400 120,000 150,320 106,400 30 80,000 80,000 106,400 120,000 150,320 106,400 36 80,000 80,000 106,400 120,000 150,320 106,400 Rated Loads (lbs) for C/asses 1,2,3 & MC I certify this CDRS complies with CONTROLREFNO. he requiremenG of the applicable code MATERIALS Plate: 5A-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A 6202 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 3A-564 TYP 630 Bergen Power Pipe Supporfs, lnc. Studs: SA-36 Product Engineering Department Exempt Cotter pins, Washers, Retainers (NF-21 21) REVISIONS At>R,&.*, $EAL /NlOriqinal lssue 10/27109 /t 147a774t ISIGNED /i BERGEN POWER PIPE SUPPORTS, INC, /3\ /t /s\ SHEET 1 OF 1 REV. A PART N0. 6202.80 CDRS CATALOG INFORMATION SHEET PIPE CUMP fOr SIRUIASSEMBI'ES . PART NUMBER 6202.80K b oo I oo PIPE SIZE 10 D E G P s 3 15 17t8 13t4 11st8, STOCK TxW 1-314x9 1-3/4 x 9 12 3 16 1718 13t4 12 3t4 14 3 17 1311t16 1-314 16 3 18 17t8 17t8 14314 1-314 157t8 1-314 17 1-314 18 3 19 1718 20 3 20 1718 24 3 23 30 3 26 17t8 17t8 13t4 13t4 13t4 13t4 13t4 13t4 36 3 291t4 1718 1314 2x11 2x11 19 1 1/16 2213116 26 x 10 x 10 x 11 x 11 5/16 2-114 x 11 NOTES: 1.)Alldimensions are in inches. 2.) Dimensions are provided for user application only. 3.) This Clamp is compatible with B-P Parts 2250,2252,2525 and 2530. 4.) lnstallation: Tension bolts to remove slack, plus ll2lurn of nut, then lock in place. ORDERING INSTRUCTIONS : Specify: Part Number, CDRS Revision Number, and Pipe Size' DGMPLE: ffizzlog /t /z\ 6202-80-R/0-16" REVISIONS /i /A /i BERGEA' POWER PIPE SUPPORIS, INC. SHEET 1 OF 1 REV. A PARr N0. 6202.80 til J, CERTIFIED DESIGN REPORT SUMMARY for * NUCLEAR POWER PLANT STANDARD SUPPORTS H PIPE CUMP for STRUI ASSEMBTTES - PART NUMBER 6202.120k b 9-9 DIRECTION OF LOADING € oo + Nott' Design Spec. No. DS-6202 Design Report No. DR-6202 Temperature: 6500F Fol. the test condition (Hydro)the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Condition 11 120,000 120,000 159,600 16 120,000 120,000 159,600 18 120,000 120.000 159,600 20 120,000 120.000 159,600 24 30 36 Level A Level D Test Gondition (see Note) 180.000 225,480 159,600 180,000 225,480 159,600 180,000 225,480 159,600 180,000 225,480 159,600 159,600 Operating Conditions Level C Level B Size 120,000 159.600 180,000 225,480 120,000 120,000 159,600 180,000 225,480 159,600 120,000 120,000 159,600 180.000 225,480 159,600 120,000 Rated Loads (lbs) for C/asses 1,2,3 & MC I certify CONTROL REF NO. tris CDRS complies with lhe rcquirements of lhe applicable ode MATERIALS Plate: 5A-36 Bolts: SA-307 Gr B 6202 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Nuts: 5A-563 Gr A Pin: SA-564 TYP 630 Bergen Power Pipe Suppods, lnc. Studs: SA-36 Product Engineering DePartment Exempt Cotter pins, Washers, Retainers (NF-2121) REVtStONS eq:* ft,d^'#" /o\ Oriqinal lssue 10/27109 SEtt lp/p>/ogIS]GNED /^ BERGEN POWERPIPE SUPPORTS, INC. /J /t\ /] SHEET 1 OF 1 REV. A PART N0. 6202.120 CDRS CATALOG INFORMATION SHEET PIPE CLAMP for SIRUIASSEI4BLIES ' PART NUMBER 6202'120k 10" b oo -.: oo PIPE SIZE D E 14 3 1/8 19114 16 3 1/8 20114 18 3 1/8 21114 20 3 1/8 221t4 24 3118 24 3t4 30 31t8 28114 36 31t8 31112 G P s 2 3132 2 3132 2 3t32 2 3132 2 3t32 2 3132 2 3t32 2112 137t8 STOCK TxW 1-3/4 x 10 x10 21t2 15 2112 161t8 1-3/4 x'10 21t2 17 1t8 1'3/4 x 10 2112 19112 1-314x14 2112 22518 21t2 26 1-314 1-314x14 1-314 x15 NOTES: 1.)Alldimensions are in inches' 2')DimensionSareprovidedforuserapplicationonly. 3')ThisClampiscompatiblewithPsA-100andB.PPart'2440. place. 4.) lnstallation: Tension bolts to remove slack, plus 1/2 tum of nut, then lock in ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size. DGMPLE: 6202-120-R/0-16" al lssue 10127109 BERGEN POWER PIPE SUPPORTS, INC' SHEET 1 oF 1 PART N0. 6202-120 titr, CERTIFIED DESIGN REPORT SUMMARY for * b NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CLAMP for SIRUI ASSEIfBITES - PART NUMBER 6202'130k b o@ DIRECTION OF LOADING oo .E- I Nott' Design Spec. No. D$6202 Temperature: 6500F Fol. the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Report No. DR-6202 Level D Test Gondition (see Note) 195,000 244,270 172,900 195.000 244,270 172,900 172,900 195,000 244,270 172,900 172,900 Operating Conditions Level C Level B Size Design Condition 14 130,000 130,000 172,900 16 130,000 130,000 172,900 1E 130,000 130,000 Level A 20 130,000 130,000 172,900 195,000 244,219 24 130,000 130,000 172,900 195,000 244,270 172,900 30 130,000 130,000 172,900 195,000 244,270 172,900 36 130,000 130,000 172,900 195,000 244,274 172,900 Rated Loads (lbs) tor C/asses 1,2,3 & MC I certify this CDRS complies with CONTROL REF NO. he MATERIALS requirements of the applicable code The Design Report & Design Specification are in Plate: 3A-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A Pin: 54-564 TYP 630 Studs: 5A-36 ile {4":,*/'&,A SEAL Va/zt/ot lslGNED rn pt p in Wa accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Bergen Power Pipe SupPorts, lnc. she -Cotter /o\ Oriqinal lssue /\ s, 6202 rs, Reta i ne rs ( N F-2 1 2 Product Engineering DePailment !L REVISIONS 1 0/27109 /t\ BERGETV POWER PIPE SUPPORTS, INC, /J /t /i SHEET 1 0F I REV, A PART NO. 6202.130 CDRS CATALOG INFORMATION SHEET PIPE CLAtrIIP fOr STRUTASSEMBTIES . PART NUMBER 6202'130K \^\4 oo %' Tvp, -: oo PIPE SIZE D E 14 3112 19114 16 3112 20114 18 31t2 21114 24 3112 3112 22114 30 31t2 28114 36 3112 20 24 314 31112 STOCK lo P s 2 3132 2 3132 2 3132 2 3132 2 3132 2 3t32 2 3132 2112 13718 1-3/4 x 10 21t2 21t2 21t2 15 1-3/4 x 10 16 1/8 1-3/4 x 10 17 118 1-il4 x10 2112 19112 1-314x14 2112 22518 2112 26 TxW 1-314 x14 1-3/4 x 15 NOTES: 1.) All dimensions are in inches' 2.) Dimensions are provided for usei application only' and2530' 3,)This Clamp is compatible with B-P Parts 2250,2252,2421,2440,2525 in place' lock then nut, plus of l12lurn 4.) lnstallation: Tension bolts to remove slack, ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size. EXAMPLE: 62A2'130-R/0-16- nallssue 10127109 AERGflV POWER PIPE SUPPORIS' INC. SHEET 1 0F 1 PART N0. 6202'130 tit f' CERTIFIED DESIGN REPORT SUMMARY for r* H NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE CLAIIIP for SIRUIASSEMBLTES - PART NUMBER 6202'200k b q9 -T DIRECTION OF LOADING : Nott' Design Spec. t{o. DS-6202 Design Report No. DR-6202 @o Temperature: 6500F Fo1. the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Size Design Condition Level A Operating Conditions Level C Level B Level D Test Condition (see Note) 16 200,000 200,000 266,000 300,000 375,800 266,000 18 200,000 200,000 266,000 300,000 375,800 266,000 20 200,000 200,000 266,000 300,000 375,800 266,000 300,000 375,800 266,000 266,000 266,000 24 200,000 200,000 200,000 30 200,000 36 266,000 200,000 266,000 300,000 375,800 200,000 266,000 300,000 375,800 Ratedloads (lbs) for C/asses 1,2,3 & MC I certify this CDRS complies with 6202 CONTROL REF NO. he MATERIALS requirements of lhe applicable code The Design Report & Design Specification are in Plate: 5A-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: 5A-564 TYP 630 Bergen Power PtPe SuPPorts, Inc. Studs: SA-36 Exempt Totter pins, Washers, Retaine1g Product Engineering DePartment l!F-!l!]) REVIS|ONS Le*hR,&,ffi /il Orioinal lssue 10/27109 /1\ Ster lto/tz/o?lslcNED /z\ BERGEN POWER PIPE SUPPORTS, NC. /J /\ /i SHEET 1 0F 1 REV. A PART NO. 6202-200 CDRS CATALOG INFORMATION SHEET PIPE CLAMP for SIRUI ASSEMBTTES 'PART NUMBER 6202-204R 10" AL b 4HF]' oo 7/n /8 Tttp. oo # _]-l l-_f PIPE SIZE D E G P s 4 16114 17 112 STOCK TxW 16 6 21 31t2 18 6 22 3112 4 20 6 23 3112 4 18 112 1-314x12 1-314x12 1-314x12 24 6 26 3112 4 207t8 1-314 x14 30 6 29 4 24118 1-314 x14 36 6 32114 3112 3112 4 27 112 1-3/4 x 15 NOTES: 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only' 3.)This Clamp is compatible with B-P Parts 2250,2252,2421,2440,2525 and2530. lock in place. 4.) lnstallation: Tension bolts to remove slack, plus 1/2 turn of nut, then ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size. DGMPLE: 6202-200-R/0-16' al lssue 10127l\g BERGEN POWER PIPE SUPPORTS, INC, PART N0. 6202-200 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS PART NAME DIRECTION OF LOADING Temperature:-1Q50'lf Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100T. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DS-6242 R0 DR-6242 R0 Rated Loads (lbs) for Classes 1,2,3 & MG )ESIGN SPEC NO.: e1 K :SIGN REPORT NO.: REV PIPE SIZE OPERATING CONDITIONS Design Test Condition Condition Level A Level B Level C Level D {see Note) 125 125 125 125 166 166 166 188 188 188 250 300 300 300 450 450 450 500 300 399 399 399 599 599 599 665 450 450 450 675 675 675 166 166 166 399 399 399 599 599 599 665 1/2 314 1 1 1t4 1 112 2 2112 3 4 6 125 125 300 300 450 450 450 500 750 250 250 600 600 600 900 900 900 1 000 I certify this CDRS complies with the requirements of the applicable Code. The Design Report & Design Specification Materials: Plate: a a (D Irl f, a a J z o E o REV ffi CLOUTIER Certification 5A-36 are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports,lnc. Product Englneerlng Department CONTROL REF BERGEN.POWER PIPE SUPPORTS, INC. Sheet 1of1 NO. 6242 A PART NO. 6242 LATERAL RESTRAINT PIPE STRAP T/16" CLR. w f "o" A B T w r/2" 1r' 3tt 2" 3/4" 1 3/16" 3" r/4" r/4" r/4" 3/9" 3/9" 3/8" 3" 3" /2" I /?" 3" 4" 4" PIPE { sv IEV ----r STZ;E 1" 1 r/4" 1 r/2" 3 r/4" 1 r3/1 6" 3 r/?" 17/16" ?,, 4" 2" 2 r/2" 4 r/2" 2 r/2" 3t' 5" 3t' 3 5/9" 4 5/8" 6 3/4" 5 r/2" 6 r/2" 8 r/2" 4" 6" 2" 2" 3r' t r/2" r /2" 6" NOTES: N o o 1. All dim ensions are in inches. 2. Dimensions are provided for user application only. 3. A full penetration weld may be used in lieu of tillet weld both sides. ct tIJ f a a Orderino lnstructions: Specity part No., CDRS revision No., and size designation. J z CI E o G Example: Part 6242 - R/0 - 4" \o tEV TiH fl BERGEN-POWER PIPE SUPPORTS HJ CDRS CATALOG INFORMATION SHEET PART DATE 6242 91112007 CERTIFIED DESIGN REPORT SUMMARY for TT7l. H NUCLEAR POWER PLANT STANDARD SUPPORTS PART NAME Hd DIRECTION OF LOADING Temperature:650 Note: 'F The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DS-6243 DR-6243 )ESIGN SPEC NO.: :SIGN REPORT NO.: Rated Loads (lbs) for classes 1,2,3 & MC F iE'v OPERATING CONDITIONS Design PIPE SIZE Condition Level A Level B Level C 600 600 600 1 500 1 500 1 500 2500 2800 2800 3000 600 798 600 798 798 900 900 900 995 995 1 995 2500 3325 2800 3724 3724 3990 1/2 314 1 1 114 1 1t2 2 2112 3 4 6 600 1 500 1 1 500 1 1 500 2800 3000 Test Condition Level D (see Note) 200 200 1 200 798 798 798 2250 2250 2250 3000 3000 3000 3750 4200 4200 4500 5000 5600 5600 6000 995 995 1 995 3325 3724 3724 3990 1 1 1 1 *itn tn" I I certify this CDRS applicable Code. I requirements of the "otOfi"t o a O) IU :f a U) The Design Report & Design Specification Materials: N Plate: EUGENE 5A-36 are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at R. CLOUTIER Bergen Power Pipe Supports, lnc. J Product Engi neerlng DePartment z (, tr CONTROLREFNO. 6243 o qKK REV Certification BERGEN.POWER PIPE SUPPONTS, INC. Sheet REV. PAt{ | N(,. 1of /a\. 6243 1 VERTICAL RESTRAINT PIPE STRAP w--l { \ s lEV PIPE STZE A B T w r/2" 3tt 29/32" 2" 3/4" 3 r/2" 1" 4" 1 r/8" 1 3/8" r/4" r/4" r/4" 1 r/4" 1 r/2" 4 r/2" 1 3/4" 5" 2" 2" 5 r/?" 2 7 /16" 3/8" 3/8" 3/8" 2 r/2" 6" 2 r5/t6" 3" 3" 3" 3" 4" 4" 3" 4" 6" 6 r/2" 3 9/16" 7 r/2" 4 9/16" 9 3/4" 5 r5/t6" 2t' ?,, r/2" r/2" r/2" r/2" 6t' NOTES: 1. All dim ensions are in inches. F- O o 2. Dimensions are provided for user application only. 3. A full penetration weld may be used in lieu of fillet weld both sides. O) uJ l a 2 Orderinq lnstructions : Specify part No., CDRS revision No., and size designation. J z g E o G Example: Part 6243 - R/0 - 4" (o REV m fl BERGEN.POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART DATE 6243 9t112007 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS OFF. AXIS PIPE CLAMP FOR STRUTS BY P.S.C. l {---} DIRECTION OF LOADING I Note: DS-6202 R3 DR-6202 R0 Rated Loads (lbs) for Glasses 1,2,3 & MC DESIGN SPEC NO.: DESIGN REPORT NO.: 6i 7 -$ REV PIPE SIZE Design Condition Level A 350 350 350 3s0 21t2 350 3 350 350 350 350 350 350 350 350 350 350 350 350 11t2 2 4 5 350 6 350 350 I 10 12 14 16 350 350 350 350 NOTE: OPERATING CONDITIONS Level B Level C 466 466 466 456 466 466 525 525 525 525 525 525 466 52s 466 525 525 525 525 525 rt66 466 466 466 Test Condition Level D (see Note) 650 466 466 466 466 466 466 466 466 466 466 466 466 650 650 650 650 650 650 650 650 650 650 650 For use only with Mechanical Struts manufactured by Pacific Scientific Company per bulletin PSA-4. This product must be used with shear lugs ,welded to the pipe, mounted at 90oto each other and 45'from the vertical centerline of the clamp. Supplied by others. lc"ry requirements of the applicable Code. I Materials: t\ o o Plate: Bolts: o, ) Pin: UJ U) Nuts: Studs: L J z o E o REV remperature: 650 " F The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. The Design Report & Design Specification SA-36 SA-307 GR B SA-654 TYPE 630 5A-563 GR A Bergen Power Pipe Supports, lnc. 54-36 Cotter pins, Washers, Retainers Exempt (NF-l110) Certification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Product Engineering Department CONTROLREFNO. BERGEN.POWER PIPE SUPPORTS, INC. 6252 Sheet REV. PAIII NU. l /a\. 6252-.95 of 1 OFF-AXIS PIPE CLAMP FOR STRUTS BY P.S.C. D .no. d O -::T::I +I PIPE SIZE 1 1t2 2 21t2 3 4 5 6 I 10 12 14 16 F- o o F o, uJ f U) L J z g o CE D E 7t16 4 3t4 5 7t16 7116 5 314 7t16 6 7 7t16 7t16 7 1t2 7t16 8 7t16 9112 7t16 11 7t16 12 7t16 13 7t16 14 G P 13t32 13t32 13t32 13t32 13t32 13t32 13t32 13t32 13t32 13t32 13t32 13t32 3t8 3/8 3t8 3t8 3t8 3/8 3/8 3t8 3t8 3t8 3/8 3/8 s STOCK 3 1/8 1t2X2 31t2 1t2 X2 1t2 3 7t8 4 3t8 1t2X2 1t2 5 1t2X2 1t2 1t2X3 SIZE TXW 1t2X 2 213t16 5112 6 13/16 8 3/16 9112 10 1/8 11 1t4 1t2 X2 112 1t2 X3 5/8 X3 5/8 X3 s/8 x3 5/8 X3 NOTES: 1 . All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with B-PPS Parts 2440 and PSA- 114. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut. then lock in place ORDERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No. and Pipe size. EXAMPLE: Part 6252-.35--Rl0-2" BERGEN.POWER PIPE SUPPONTS INC. CDRS CATALOG INFORMATION SHEET PART 6252-.35 DATE 9/01 t2007 a nls H CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS OFF - AXIS PIPE CLAMP FOR STRUTS BY P.S.C. Hd 90" --r {* DIRECTION OF LOADING I Note: 'F DS-6202 R3 DR-6202 R0 DESIGN SPEC NO.: DESIGN REPORT NO.: Rated Loads (lbs) tor classes 1,2,3 & MG a RRV femperature: 650 The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100oF. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. PIPE SIZE Test Condition Condition Level A Level B Level C Level D (see Note) 650 650 650 650 650 650 650 650 650 650 650 650 650 650 650 650 650 650 650 650 650 650 650 650 865 865 865 865 865 865 865 865 865 865 865 865 975 975 975 1220 1220 1220 1220 1220 1220 1220 1220 1220 1220 1220 1220 865 865 865 865 865 865 865 865 865 865 865 865 11t2 2 21t2 3 4 5 6 8 10 12 14 16 NOTE: OPERATING CONDMONS Design 975 975 975 975 975 975 975 975 975 For use only with Mechanical Struts manufactured by Pacific Scientific Company per bulletin PSA-4. This product must be used with shear lugs ,welded to the pipe, mounted at 90oto each other and 45ofrom the vertical centerline of the clamp. Supplied by others. -".ry requirements of the applicable Code. I The Design Report & Design Specification Materials: r\ O Plate: Bolts: Pin: Nuts: Studs: <) o) LU l a a J z sA-36 SA-307 GR B 5A-654 TYPE 630 5A-563 GR A SA-36 are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, lnc. Product Engineering Department CI CE (K Ootter pins, Washers, Retainers Exempt (NF-1 110) o 7 e REV Certification CONTROLREFNO. BERGEN.POWEN PIPE SUPPORTS, INC. 6252 Shest REV. PAH| N(,. l /a\. 6252-.65 of 1 OFF-AXIS PIPE CLAMP FOR STRUTS BY P.S.C. G 10" _t D --P nno. d O I + I 6 6 lEV PIPE SIZE 1 112 2 2 1t2 3 4 5 6 8 10 12 14 16 F- c) o o, TIJ l ct) a J z 0 E o G G D 7t16 7t16 7t16 7t16 7t16 7t16 7t16 7t16 7116 7t16 7t16 7t16 E G 4 314 13t32 13t32 5 5 314 13t32 13t32 6 13t32 7 7 1t2 13t32 13t32 8 91t2 13t32 11 13t32 13t32 12 13t32 13 13t32 14 STOCK P S SIZE TXW 3t8 213t16 1t2X2 3/8 3 1/8 3t8 3t8 3t8 31t2 1t2X 2 1t2X2 1t2 1t2 X2 112 1t2X2 112 1t2X2 1t2 1t2X3 3/8 3/8 3t8 3t8 3/8 3/8 3t8 3 7t8 4 3t8 5 5112 6 13/16 3/16 8 9112 10 1/8 11 1t4 1t2 X3 5/8 X3 s/8 x3 5/8 X3 5/8 X3 NOTES: 1 . All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with B-PPS Parts 2440 and PSA- 112. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut. then lock in place ORDERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No. and Pipe size. EXAMPLE: Part 6252-.65--Rl0-2" REV rns fl BERGEN.POWER PIPE SUPPORTS INC. PART 6252-.65 CDRS CATALOG INFORMATION SHEET DATE 9/01t2007 Hf a ms H CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES Hd 90" \ <+ DIRECTION OF LOADING I DESIGN SPEC NO.: DESIGN REPORT NO.: SI F IRV remperature:-U The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. Note: PIPE SIZE DS-6252 Rated Loads (lDs) ror glasses 1r2r3 & M(; OPERATING CONDITIONS Design Condition Level A Level B 1 1t2 700 2 700 931 931 112 700 700 700 700 700 700 700 700 700 700 700 700 700 700 2 3 700 700 700 4 5 6 I 700 700 700 700 10 12 14 16 700 NOTE: Test Condition Level C Level D (see Note) 050 1 050 1 050 1 050 1 050 1 050 1 050 1 050 1 050 1 050 1 050 1 050 1300 1300 1300 1300 1 300 1 300 1 300 1300 1300 1300 1300 1 300 931 931 931 931 931 931 931 931 931 931 931 931 931 931 931 931 931 931 931 931 931 931 1 This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each other and 45'from the vertical centerline of the clamp. Supplied by others. requirements of the applicable Code. o o Plate: Bolts: Pin: Nuts: Studs: o, t.U f a a ) z g tr o REV The Design Report & Design Specification Materials: N lotter pins, Washers, Retainers Exempt Certification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at 5A-36 SA-307 GR B 5A-654 TYPE 630 S4-563 GR A 5A-36 Bergen Power Pipe Supports, lnc. Product Engineering DePartment (NF-1 110) CONTROLREFNO. BERGEN.POWER PIPE SUPPORTS, INC. Sheet 1of1 REV. ,A 6252 PART NO. 6252-.7 OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES D d 7l\ \to I 6 lEV PIPE SIZE 1 112 2 2 112 3 4 5 6 I 10 12 14 16 ro o F CD LU f ct) a J z 0 E o <" G E D t16 4 314 7 t16 5 7 t16 5 314 7 t16 6 7 7 7116 7116 7 112 7116 8 t16 7 t16 7 t16 7 t16 7 t16 7 I 112 11 12 13 14 .no. I G P 17132 17132 17132 17132 17132 17132 17132 17132 17132 17132 17132 17132 3/8 3/8 3/8 318 3/8 318 318 318 STOCK SIZE TXW 1l2X 2 213116 1lzx 2 3 1/8 112X2 112 3 112 112X2 112 3 718 4 3t8 1t2X2 112 112X2 112 5 S 5 112 6 13/1 6 318 8 3116 I 112 318 318 101/8 11 114 318 1t2X3 1t2X3 5/8 5/8 5/8 5/8 X3 X3 X3 X3 NOTES: 1 . All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420 and 2440. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut. then lock in place ORDERING INSTRUCTIONS : Specify Part No. ,Size Designation, CDRS Rev. No. and Pipe size. EXAMPLE: Part 6252-.7 -Rl0-2" lEV fi75 E BERGEN-POWER PIPE SUPPORTS INC. HN CDRS CATALOG INFORMATION SHEET PART 6252-.7 DATE 9/01t2007 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS OFF - AXIS PIPE CLAMP FOR STRUT ASSEMBLIES .e DIRECTION OF LOADING I Note: femperature: 650 " F is for Design and Operating Conditions. For the Test Condition (Hydro) The temperature shown above the maximum temperature is 100'F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: DS-6202 R3 DR-6202 R0 HateilL6eds (lbs) tor Classes 1,2,3 & MC RRV Design PIPE SIZE Condition Level A 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 2 21t2 3 4 5 6 8 10 12 14 16 18 20 NOTE: OPERATING CONDMONS Level C Level B 1995 1995 1995 1995 1995 1995 1995 1995 1995 1995 1995 1995 1995 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 Test Gondition Level D (see Note) 2820 2820 2820 2820 2820 2820 2820 2820 2820 2820 2820 2820 1995 1995 1995 1995 1995 1995 1995 1995 1995 1995 1995 1995 1995 2821 This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each other and 45ofrom the vertical centerline of the clamp. Supplied by others. I certify this CDRS complies with the requirements of the applicable Code. o o o, LU :) a @ The Design Report & Design Specification Materials: F- EUGENE R. CLOUTIER J Plate: Bolts: Pin: Nuts: Studs: 5A-36 SA-307 GR B 5A-654 TYPE 630 5A-563 GR A 5A-36 g = (r Cotter pins, Washers, Retainers Exempt (NF-1 110) o REV Certification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, lnc. Product Engineering DePartment CONTROLREFNO. BERGEN.POWER PIPE SUPPORTS, INC. Sheot lof 1 REV. ,/N 6252 PART NO. 6252-1.5 OFF-AXIS PIPE CLAMP FOR STRUT ASSEMBLIES 10" D d 0 I +- 5 C \(Y) REV D E G* 2 518 2112 5/8 5/8 5 5 314 6 7 21132 21132 21132 21132 21132 21132 21132 21132 21132 21132 21132 21132 21132 20 N o o o, uJ l a U) J z o (E o G G lEV TFTS U I PIPE SIZE 3 4 5 6 8 10 12 14 16 18 .no. 518 5/8 5/8 5/8 5/8 5/8 5/8 5/8 518 5/8 7 I 112 8 112 11 12 13 14 15 16 S P 3 112 112 112 112 112 112 112 112 112 112 112 112 112 STOCK SIZE TXW 114 3 5/8 4 415116 5 9/1 6 6 112 7 13116 I 114 10 3/8 11 12 13 14 5/8X3 5/8X3 5/8X3 314X3 314X3 314X3 3t4X3 314X4 314X4 314X4 314X4 314X5 314X5 NOTES: 1 . All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440,2525 2530 and PSA-1 per PSA Bulletin PSA-4. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut. then lock in place 4. * G=1/2" when used with PSA-1. ( Use alternate washers supplied.) ORDERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size. and "G" Required. EXAMPLE: Part 6252-1.5-Rl0-2" G= 21132" BERGEN-POWER PIPE SUPPORTS INC. H* CDRS CATALOG INFORMATION SHEET PART 6252-1 .5 DATE 9/01 t2007 ffi ru CERTIFIED DESIGN REPORT SUMMARY lor NUCLEAR POWER PLANT STANDARD SUPPORTS OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES f----- 90" _\ {* DIRECTION OF I Note: The temperature shown above is for Design and Operating Conditions. For the Test Condi the maximum temperature is 100'F. For higher temperatures in the Test Condition use Level B loads Temperature: 650 up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: LOADING 'F DS-6202 R3 DR-6202 R0 Rated Loads (lbs) for Classes 1,2,3 & MC PIPE SIZE tEr F t\ Level A Level B Level C Level D (see Note) 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 4000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 5600 5600 5600 5600 5600 5600 5600 5600 5600 5600 5600 5600 5600 5600 4000 4000 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 5600 5320 5320 5320 5320 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 4000 4000 4000 34 36 NOTE: r cenry rnrs uu.D Test Condition Condition 3 I OPERATING CONDITIONS Design 4000 4000 4000 4000 5320 5320 5600 5600 5600 5600 5320 This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each other and 45ofrom the vertical centerline of the clamp. Supplied by others. "oroffiTl Code. I equirements of the applicable The Design Report & Design Specification Materials: N Plate: Bolts: Pin: Nuts: Studs: o o O) tu l a a J z are in accordance with ASME B PVC Section lll, Subsection NF, 2007 Edition and are on file at 5A-36 SA-307 GR B 5A-654 TYPE 630 54-563 GR A Bergen Power Pipe Supports, lnc. Product Engineering Department SA-36 (9 tE ]otter pins, Washers, Retainers Exempt o REV Certification (NF-1 110) CONTROLREFNO. BERGEN.POWER PIPE SUPPORTS, INC. Sheet 1of 1 REV. ,4. 6252 PART NO. 6252-4 a OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES 10" .P I -T t-l 16" THRU 36" ONLY PIPE SIZE 3 4 5 6 I C \ct) REV to o F o, 10 12 14 16 18 20 22 24 26 28 30 32 34 36 D E G P S 7t8 7t8 7t8 7t8 7t8 7 3t4 8114 8 314 I 1t2 10 112 21t32 21t32 21t32 21t32 4 3t4 6 1t4 6 7t8 7 5t8 7t8, 12 13 14 15 16 17 18 19 20 22 23 24 25 26 21t32 21t32 21t32 21t32 21t32 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 7t8 7t8 7t8 7ta 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 21132 21132 21t32 21t32 21132 21t32 21t32 21t32 21t32 21t32 1X6 1114X5 114 11t4X5 11t4)(5 11t4)(5 10 1/2 1114)(6 115/8 121t4 11t4X6 I 1 STOCK SIZE TXW 1 13/16 131/8 14 3t8 15 3/8 16 15/16 18 114 19 114 20 3t8 21 3t8 22 3t8 23 3t8 1114)(6 11t4X7 11t4X7 11t4X7 11t4X7 11t2X7 11t2)(7 1112)(7 11t2X7 11t2X7 11t2)(7 11t2X8 NOTES: 1 . All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2525 and 2530. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12turn of the nut. then lock in place 4.4 Bolt configuration for pipe sizes 16" through 36" only. uJ f U) U) z o E o G ORDERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size. EXAMPLE: Part 6252-4-Rl0-4" s G IEV ffi fl BERGEN-POWER PIPE SUPPORTS INC. CDRS CATALOG INFORMATION SHEET PART 6252.4 DATE 9t1t2007 a CERTIFIED DESIGN REPORT for NUCLEAR POWER PLANT STANDARD SUPPORTS Note: + DIRECTION lor Condi LOADING The temperature shown above is for Design and Operating Conditions. For the Test the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads Temperature: 650 o F up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: DS-6202 R3 DR-6202 R0 Rated Loads (lbs) for Classes 1,2,3 & MC PIPE SIZE 3 4 5 6 I 10 12 14 16 18 20 22 24 26 28 30 32 34 36 NOTE: I certify OPERATING CONDITIONS Design Condition Level A Level B Level G this CDRS complies with the The Design Report & Design Specification o o O) l U) U) J z (t (E o (see Note) 7980 1 1208 7980 9000 6000 7980 11208 7980 9000 6000 7980 7980 11208 9000 6000 7980 7980 1 1208 9000 6000 7980 11208 7980 9000 6000 7980 1 1208 7980 9000 6000 7980 11208 7980 9000 6000 7980 11208 7980 9000 6000 7980 7980 9000 1 1208 6000 7980 11208 7980 9000 6000 7980 11208 7980 9000 6000 7980 11208 7980 9000 6000 7980 11208 7980 9000 6000 7980 11208 7980 9000 6000 7980 1 1208 7980 9000 6000 7980 1 1208 7980 9000 6000 7980 11208 7980 9000 6000 7980 1 1208 7980 9000 6000 7980 1 1208 7980 9000 6000 per Pacific Company manufactured Scientific by For use only with Mechanical Struts bulletin PSA-4. This product must be used with shear lugs ,welded to the pipe, mounted at 90oto each other and 45ofrom the vertical centerline of the clamp. Supplied by others. 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 N tIJ Test Condition Level D ffi CLOUTIER Bolts: Pin: Nuts: SA-307 GR B 5A-654 TYPE 630 5A-563 GR A are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, lnc. Product Engineering Department Washers, Retainers Exempt (NF-111 BERGEN.POWER PIPE SUPPORTS, INC. OFF-AXIS PIPE CLAMP FOR STRUTS BY P.S.C. l-e l* wt 10" l ;P D.^0. t T t-l 16" THRU 36" ONLY \to 6 lEV F* o o F ct) uJ f U) PIPE SIZE D 3 1 4 1 5 6 1 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 E 7 3t4 f31t4 8 3t4 G 13/16 13/16 13/16 91t2 13/16 10 1t2 13t16 12 13/16 13/16 13 13/16 14 13t16 15 16 13/16 17 13/16 18 13/16 19 13/16 13/16 20 13/16 22 23 13/16 13/16 24 25 13t16 13/16 26 P S 3t4 3t4 4 314 314 314 314 6 7t8 7 5t8 9114 10 1t2 61t4 3t4 314 314 314 314 314 314 3t4 3t4 314 314 314 314 3t4 115/8 12 114 1 13/16 13 1t8 14 3t8 15 3/8 16 15/16 18 114 19 1t4 20 3t8 21 3t8 22 3t8 23 3t8 1 STOCK SIZE TXW 1X6 11t4X5 11t4X5 1114)(5 11t4)(5 11t4X6 11t4)(6 11t4X6 11t4X7 1 1t4 X7 1114)(7 1 114 X7 1 1t2X7 11t2X7 1 1t2X7 1 1t2X7 1 1t2X7 1 1t2X7 11t2X8 NOTES: 1 . All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with PSA-3. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12turn of the nut. then lock in place. 4.4 Bolt configuration for pipe sizes 16" through 36" only. U' J z 0 o ORDERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size. CT G G EXAMPLE: Part 6252-6-R l0-4" IEV ffi fl BERGEN-POWER PIPE SUPPORTS INC. CDRS CATALOG INFORMATION SHEET PART 6252.6 DATE 9t1t2007 ms H CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS OFF - AXIS PIPE CLAMP FOR STRUT ASSEMBLIES Nd go" t {--} rl Note: The temperature shown DIRECTION OF LOADING is for Design and Operating Conditions. For the Test Condi "oorl" is 100'F. For higher temperatures in the Test Condition use Level B loads the maximum temperature Temperature: up to the temperature shown for the Operating Condition. 650 'F DS-6202 R3 DR-6202 R0 DESIGN SPEC NO.: DESIGN REPORT NO.: Rated Loads (lbs) for Classes 1,2,3 & MC PIPE SIZE G 4 RRV 5 Design Condition Level A 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 NOTE: 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 Test Condition Level D (see Note) 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 This product must be used with shear lugs,welded to the pipe, mounted at 90'to each other and 45'from the vertical centerline of the clamp. Supplied by others. *"*ry requirements of the applicable Code. I The Design Report & Design Specification Materials: I- o o Plate: Bolts: Pin: Nuts: Studs: o, r.rJ f a a J z 0 E o EKK REV OPERATING CONDMONS Level C Level B 5A-36 SA-193 SA-654 SA-194 SA-193 GR 87 TYPE 630 GR 2H GR 87 Ootter pins, Washers, Retainers Exempt (NF-1 110) Certification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, lnc. Product Engineering DePartment CONTROLREFNO. BERGEN.POWEB PIPE SUPPORTS, INC. Sheet REV. 1of /a\. 1 6252 PART NO. 6252-7 OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES G 10" tIP -f t-l PIPE SIZE 4 5 6 I \lJ) 6 lEV 10 12 14 16 18 20 22 24 26 28 30 32 34 36 l- o o CD D E G 1 1t4 8114 29t32 1 1t4 8 314 29t32 1 114 I 112 29t32 1 114 10 1t2 29t32 29t32 12 1 114 29t32 13 1 114 14 29t32 1 1t4 29t32 15 1 114 16 29t32 1 1t4 17 29t32 1 114 18 29t32 1 114 29t32 19 1 114 29t32 1 114 20 29t32 1 114 22 29t32 1 114 23 29t32 24 1 114 29t32 1 114 25 29t32 1 114 26 P s 314 5 314 3t4 61t2 314 314 314 314 314 7 1t8 3t4 314 3t4 3t4 314 3t4 3t4 314 3t4 3t4 314 8 3/8 I314 1 1 1116 12 3t8 13 3/8 14 1t2 15 1t2 16 5/8 17 5t8 18 314 20 5t8 21 314 22 314 23 3t4 24 3t4 STOCK srzE Txw 11t2X7 1 1t2 X7 1112X7 11t2X7 11t2X8 11t2X8 13t4X7 13t4X7 13t4X7 13t4X8 13t4X8 13t4X8 13/4X9 2X8 2X8 2X8 2X9 2X9 NOTES: 1. All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440, 2525 and 2530. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut. then lock in place. ) r.rJ U) U) J z 0 E o G G tEV ffi H OR DERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size EXAMPLE: Part 6252-7-RlO-4" BERGEN-POWER PIPE SUPPORTS INC. CDRS CATALOG INFORMATION SHEET PART 6252.7 DATE 9t1t2007 ffi CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS OFF. AXIS PIPE CLAMP FOR STRUT ASSEMBLIES H 90" l<+ -]-l DIRECTION OF Note: The temperature shown "oorl," LOADING is for Design and Operating Conditions. For the Test Condi the maximum temperature is 100'F. For higher temperatures in the Test Condition use Level B loads Temperature: up to the temperature shown for the Operating Condition. 650 'F DS-6202 R3 DR-6202 R0 DESIGN SPEC NO.: DESIGN REPORT NO.: Rated Loads (lbs) lor Classes 1,2,3 & MC PIPE SIZE Design Gondition 4 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 5 6 F IRV I 10 12 14 16 18 20 22 24 26 28 30 32 34 36 NOTE: OPERATING CONDITIONS Level B Level C Level D (see Note) 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 18000 18000 18000 18000 18000 18000 18000 18000 18000 18000 18000 18000 18000 18000 18000 18000 18000 18000 16800 16800 16800 16800 16800 16800 16800 16800 16800 16800 16800 16800 16800 16800 16800 16800 16800 16800 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 15960 This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each other and 45ofrom the vertical centerline of the clamp. Supplied by others. *" requirements of the applicable Code. I The Design Report & Design Specification Materials: Ptate: Bolts: Pin: Nuts: Studs: sA-36 SA-193 GR 87 5A-654 TYPE 630 SA-194 GR 2H SA-193 GR 87 Cotter pins, Washers, Retainers Exempt (NF-1 110) REV Test Condition Level A Certification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, Inc. Product Engineering Department CONTROLREFNO. BERGEN.POWER PIPE SUPPORTS, INC. Sheet lof1 REV. ,/N 6252 PART NO. 6252-12 OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES G 10" IP t I d6 I f ---r--- t-l \l{) 6 lEV to F o o, uJ PIPE SIZE 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 D E G 1 114 8114 29t32 1 114 8 314 29t32 1 114 91t2 29t32 1 114 10 112 29t32 12 29t32 1 114 29t32 13 1 114 29t32 14 1 114 29t32 15 1 1t4 29t32 16 1 114 29t32 17 1 114 29t32 18 1 1t4 29t32 19 1 114 29t32 1 114 20 29t32 1 114 22 11t4 23 29t32 29t32 1 114 24 29t3,2 1 114 25 29t32 1 114 26 STOCK P S SIZE TXW 3t4 5 314 6112 7 118 I 3/8 11t2X7 1 1t2 X7 314 314 3t4 3t4 3t4 314 3t4 314 314 314 3t4 314 3t4 314 3t4 3t4 314 I314 1 1 1t16 12 3t8 13 3/8 14112 15 1t2 16 5/8 17 518, 18 3t4 20 5t8 21 3t4 22 3t4 23 3t4 24 3t4 1112X7 11t2X7 11t2X8 11t2X8 1314X7 X7 X7 13t4X8 13t4X8 13t4X8 13t4X9 1 3t4 1 3t4 2X8 2){8 2X8 2X9 2X9 NOTES: 1 . All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440, 2525 and 2530. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12turn of the nut. then lock in Place. = U) I z <" g (r o G ORDERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size . EXAMPLE: Part 6252'12'Rl0'4" EV ffi E BERGEN-POWER PIPE SUPPORTS INC. CDRS CATALOG INFORMATION SHEET PART 6252-12 DATE 9t1t2007 rn; H CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS OFF. AXIS PIPE CLAMP FOR STRUTS BY P.S.C. Nd 90" I -]-t DIRECTION OF Note: The temperature shown "oo,l" LOADING is for Design and Operating Conclitions. For the Test Condi the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads Temperature: up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: PIPE SIZE Design Condition 4 qt F iR 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 NOTE: 650 'F DS-6202 R3 DR-6202 R0 Rated Loads (lbs) lor Classes 1,2,3 & MC OPERATING CONDITIONS Test Condition Level A Level B Level C Level D (see Note) 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 15000 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 22500 22500 22500 22500 22500 28200 28200 28200 28200 28200 28200 28200 28200 28200 28200 28200 28200 28200 28200 28200 28200 28200 28200 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 19950 22sOO 22500 22500 22500 22500 22500 22500 22500 22500 22500 22500 22500 22500 For use only with Mechanical Struts manufactured by Pacific Scientific Company per bulletin PSA-4. This product must be used with shear lugs ,welded to the pipe, mounted o at 90 o to each other and 45 from the vertical centerline of the clamp. Supplied by others. r cenry Inrs uuFrD requirements of the applicable "otiffiTfi Code. I Plate: Bolts: Pin: Nuts: Studs: o, Irl f a a J z 0 E. o REV The Design Report & Design Specification Materials: r\ o o lotter pins, Washers, Retainers Exempt Cerlification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at 5A-36 SA-193 GR 87 SA-194 GR 2H SA-193 GR 87 5A-36 Bergen Power Pipe Supports, lnc. Product Engineering Department (NF-1 110) CONTROL BERGEN.POWER PIPE SUPPORTS, INC. REFNO. Sheet lof 1 A 6252 PART NO. 6252-15 OFF-AXIS PIPE CLAMP FOR STRUTS BY P.S.C. w __+.1 D r^o. dd - T------ r __t]__ tt tt 6 6 REV F- o o o) uJ f a PIPE SIZE 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 E D 7t8 7t8 7t8 7/8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 1 I3t4 1 I 1t2 1 10 1t2 1 12 1 1 13 14 1 1 15 1 16 1 17 1 18 1 19 1 20 1 22 1 23 24 1 1 25 1 26 I 114 G 3t32 3t32 3t32 3t32 3t32 3t32 3t32 3t32 3t32 3t32 3t32 3t32 s STOCK SIZE TXW 1 5 314 6 1t2 7 1t8 8 7t8 1 I3t4 1 1t2X7 1 1t2X7 1 1t2X7 1 1t2X7 1 1t2X 8 P 1 1 1 1 1 1 1116 1 12 3t8 13 3/8 1 141t2 1 1 1 1 3132 1 3t32 3t32 3t32 3t32 3t32 1 1 1 1 1 15 1t2 16 5/8 17 5t8 18 3t4 20 5t8 21 3t4 22 3t4 23 3t4 24 3t4 11t2X8 1 314 X7 1 314 X7 13t4X7 13t4X8 13t4 X I 13t4 X I 13t4 X 9 2X8 2X8 2X8 2X9 2X9 NOTES: 1 . All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with PSA-10. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut. then lock in place. a J z q IE o G G lEV ri\f, fl ORDERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size . EXAMPLE: Part 6252-15-R/0-4" BERGEN-POWER PIPE SUPPORTS INC. Hd CDRS CATALOG INFORMATION SHEET PART 6252-15 DATE 9t1t2007 ffi CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES E dd I € T -' +t DIRECTION OF Note: LOADING is for Design and Operating Conditions. For the Test Condi The temperature shown "oorl. the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads Temperature: up to the temperature shown for the Operating Condition. 650 'F DS-6202 R3 DR-6202 R0 DESIGN SPEC NO.: DESIGN REPORT NO.: Rated Loads (lbs) for Classes 1,2,3 & MC PIPE SIZE Level A Level B Level C Level D (see Note) 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 25000 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 25000 25000 25000 25000 25000 33250 33250 33250 33250 37500 37500 37500 37500 37500 37500 37500 37500 37500 37500 37500 37500 37500 37500 37500 37500 37500 37500 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 5 6 E I 10 12 14 16 18 20 22 24 26 28 30 32 25000 25000 34 36 NOTE: 25000 25000 25000 33250 0 This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each other and 45ofrom the vertical centerline of the clamp. Supplied by others. *" equirements of the applicable Code. I The Design Report & Design Specification Materials: F- o o Plate: Bolts: Pin: Nuts: o, tu f a a Studs: J z o tr o S4-36 SA-193 5A-654 SA-194 SA-193 GR 87 TYPE 630 GR 2H GR 87 Cotter pins. Washers, Retainers Exempt (NF-1110) P REV Test Condition Condition 4 F OPERATING CONDITIONS Design are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, lnc. Product Engineering Department CONTROLREFNO. BERGEN.POWER PIPE SUPPORTS, INC. Gertification Sheet l_of 1 A 6252 PARI NO. 6252-25 a OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES 10" ;P I D pno. --r l-l tt PIPE stzE \lr)l 6 lEV 5 6 I 10 12 14 16 18 20 24 30 36 f- o o CD uJ l U) a J z g E o D E 2114 10 21t4 11 12 2 1t4 2 114 13 1t2 2 114 15 21t4 2114 2 114 2 1t4 2 1t4 2 114 2114 16 17 18 19 22 25 28 1 1 1 1 G P S 7116 7116 1 6 7t8 I 1t8 9 3/8 10 5/8 11 718 12 1t2 13 5/8 14 3t4 15 718 18 1t8 21 5t8 24 3t4 7t16 7t16 7t16 7t16 1 1 17t16 1 7t16 1 7116 17t16 1 1 7t16 7t16 1 1 1 1 1 1 1 1 1 1 1 STOCK SIZE TXW 1 3t4 X 2X8 2X9 I 2X 10 2X 11 2X 11 2X 12 2X 12 2X 12 2X 14 2X 15 2X 16 NOTES: 1 . AII dimensions are in inches and are provided for user information only. 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440, 2525 and 2530. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut. then lock in place. ORDERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size . EXAMPLE: Part 6252-25-R/0-6" G lEV fi\; BERGEN-POWER PIPE SUPPORTS INC. Hfl fl CDRS CATALOG INFORMATION SHEET PART 6252-25 DATE 9t1t2007 CERTIFIED DESIGN REPORT SUMMARY E\n ru for NUCLEAR POWER PLANT STANDARD SUPPORTS OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES Hd 90" | +-+ rl DIRECTION OF Note: The temperature shown "ooJ" LOADING is for Design and Operating Oonditions. For the Test Condi the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads Temperature: up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: 650 'F DS-6202 R3 DR-6202 R0 Rated Loads (lbs) lor Classes 1,2,3 & MC PIPE SIZE G RRV 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 4 5 6 8 10 12 14 16 18 20 22 24 26 28 35000 35000 35000 35000 35000 30 32 34 36 NOTE: OPERATING CONDMONS Design Condition Test Condition Level A Level B Level C Level D (see Note) 35000 35000 35000 35000 46550 46550 46550 46550 46550 52500 52500 52500 52500 49000 49000 49000 49000 49000 49000 49000 49000 49000 49000 49000 49000 49000 49000 49000 49000 49000 49000 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 35000 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 46550 52500 52500 52500 52500 52500 52500 52500 52s00 52500 52500 52500 52500 52500 52500 This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each other and 45"from the vertical centerline of the clamp. Supplied by others. I certify this CDRS complies with the requirements of the applicable Code. o o Plate: l a Bolts: Pin: z Studs: o) uJ Nuts: IJ g o CE SA-36 SA-193 5A-654 SA-194 SA-193 GR 87 TYPE 630 GR 2H GR 87 Cotter pins, Washers, Retainers Exempt (NF-1 110) qKK REV The Design Report & Design Specification Materials: F* Certification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, lnc. Product Engineering Department CONTROLREFNO. BERGEN.POWER PIPE SUPPORTS, INC. Sheet l_of 1 REV. /a\. 6252 PART NO. 6252-35 OFF-AXIS PIPE CLAMP FOR STRUT ASSEMBLIES !<__ w ---- 10" I 1 D ;P L n^0. -T C, 6 IEV l- o o F o, IIJ f v) I J z (t E o G PIPE SIZE 8 10 12 14 16 18 20 24 30 36 D E G P 2 5t8 2 5t8 2 5t8 2 5t8 2 5t8 2 5t8 2 5t8 2 5t8 2 5t8 2 5t8 13 14 1 17t32 1 17t32 1 17t32 1 17t32 1 17t32 1 17t32 1 17t32 1 17t32 1 17t32 1 17t32 1 1t4 1 1t4 1 1t4 1 1t4 1 1t4 1 1t4 1 1t4 1 1t4 1 1t4 1 1t4 15112 16 17 18 19 1t2 22 1t2 25 1t2 29 S I 114 10 1t2 11 3t4 12 1t2 13 5/8 14 3t4 15 7t8 19 1t4 22 3t8 25 1t2 STOCK SIZE TXW 2X 13 2X 14 2X 15 2X 15 2X 15 2X 15 2X 16 21t2 X 16 21t2 X 16 21t2 X 16 NOTES: 1 . All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440, 2525 and 2530. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut. then lock in place. ORDERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size . EXAMPLE: Part 6252-35-R/0-10" REV ffi fl BERGEN-POWER PIPE SUPPORTS INC. CDRS CATALOG INFORMATION SHEET PART 6252-35 DATE 911t2007 CERTIFIED DESIGN REPORT SUMMARY E7; H lor NUCLEAR POWER PLANT STANDARD SUPPORTS OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES Hd 90" -Y- \ 64 {* _I-I - ftDIRECTION OF Note: The temperature shown "oo,l" LOADING is for Design and Operating Conditions. For the Test Condi the maximum temperature is 100oF. For higher temperatures in the Test Condition use Level B loads Temperature: up to the temperature shown for the Operating Condition. 650 o F DS-6202 R3 DR-6202 R0 DESIGN SPEC NO.: DESIGN REPORT NO.: Rated Loads (lbs) lor Glasses 1,2,3 & MC PIPE SIZE G 4 RRV 5 6 Design Condition 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 I 10 12 14 16 18 20 22 24 26 28 30 32 34 36 NOTE: OPERATING CONDMONS Test Condition Level A Level B Level C Level D 50000 66500 66500 66500 66500 66500 66500 66500 66500 56500 66500 66500 66500 75000 75000 75000 75000 75000 75000 7s000 75000 75000 75000 75000 75000 75000 75000 75000 75000 75000 75000 94000 94000 94000 94000 94000 94000 94000 94000 94000 94000 94000 94000 94000 94000 94000 94000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 50000 66s00 66500 66500 66500 66500 66500 (see Note) 0 66500 66500 65500 66500 66500 66500 66500 66500 66500 66s00 66500 66500 66500 66500 66500 66500 66500 9r1000 94000 This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each other and 45ofrom the vertical centerline of the clamp. Supplied by others. equirements of the applicable Code. I The Design Report & Design Specification Materials: N o o Plate: Bolts: Pin: Nuts: 3tuds: o) ul l U) IJ z 5A-36 SA-193 GR 87 5A-654 TYPE 630 SA-194 GR 2H SA-193 GR 87 are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe SupPorts, lnc. Product Engineering Department g (r Sotter pins, Washers, Retainers Exempt (NF-1 110) o CONTROL REFNO. Sheet REV Certification BERGEN.POWER PIPE SUPPORTS, INC. lof 1 A 6252 PAHI N(J. 6252-50 OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES D PIPE stzE C 6 lEV l- o o F CD [! :) ct) a J z (, E 10 12 14 16 18 20 22 24 26 28 30 32 34 36 D E G P S 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 14 1t4 15 3t4 16 3t4 17 3t4 18 3t4 20 21 3t4 13t4 13t4 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 10 3/8 11 5/8 1 3t4 1 3t4 13t4 13t4 13t4 223t4 13t4 23 3t4 13t4 25 1t2 13t4 26 3t4 13t4 27 3t4 13t4 28 3t4 13t4 29 3t4 13t4 p^o. STOCK SIZE TXW 123t8 13 1t2 14 5t8 157t8 18 19 1/8 20 1t8 221t8 231t4 241t4 25 3t8 26 3t8 2X 2X 16 18 2 X 19 2 X 19 2X20 21t4 21t2 21t2 21t2 23t4 23t4 23t4 23t4 23t4 X 20 X 16 X 16 X 16 X 16 X 16 X 16 X 16 X 16 NOTES: 1 . All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440, 2525,2530 and PSA-35 (as per bulletin PSA-4. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut. then lock in place. ORDERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size . o G G EXAMPLE: Part 6252-50-Rl0-12" lEV TFA BERGEN-POWEN PIPE SUPPORTS INC. Hd H CDRS CATALOG INFORMATION SHEET PART 6252-50 DATE 9t1t2007 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES f-- dd 90" -\ G-* T=- -]-t NOte: The temperature shown "oorl,, DIRECTION OF LOADING is for Design and Operating Conclitions. For the Test Condi the maximum temperature is 100oF. For higher temperatures in the Test Condition use Level B loads Temperature: up to the temperature shown for the Operating Condition. Design Condition Level A 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 4 RRV 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 NOTE: 'F DS-6202 R3 DR-6202 R0 Rated Loads (lbs) for Classes 1,2,3 & MC DESIGN SPEC NO.: DESIGN REPORT NO.: PIPE SIZE 650 OPERATING CONDMONS Level C Level B 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 Test Condition Level D (see Note) 112800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 112800 112800 12800 12800 1 12800 1 12800 1 12800 1 12800 1 12800 1 12800 1 12800 1 12800 1 12800 1 12800 1 12800 1 1 112800 112800 This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each other and 45ofrom the vertical centerline of the clamp. Supplied by others. -"*ry requirements of the applicable Code. I The Design Report & Design Specification Materials: N Plate: Bolts: Pin: Nuts: Studs: o o O) )a ul a J z 54-36 SA-193 SA-654 SA-194 SA-193 GR 87 TYPE 630 GR 2H GR 87 are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, lnc. Product Engineering DePartment (9 (r ]otter pins, Washers, Retainers Exempt (NF-1 110) o \KK REV Certification CONTROLREFNO. BERGEN.POWER PIPE SUPPORTS, INC. Sheet l-of 1 A REV. 6252 PART NO. 6252-60 OFF-AXIS PIPE CLAMP FOR STRUT ASSEMBLIES D n^o. t-t tt Jr) 6 lEV N o o o, TIJ f U) a J z o E o <' G lEV PIPE SIZE 10 12 14 16 18 20 22 24 26 28 30 32 34 36 D E G P S 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 21t4 141t4 13t4 15 3t4 16 3t4 17 3t4 18 3t4 20 21 3t4 22 3t4 23 3t4 25 1t2 26 3t4 27 3t4 28 3t4 29 3t4 1 3t4 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 10 3/8 11 5/8 13t4 13t4 1 3t4 1 3t4 13t4 13t4 13t4 13t4 13t4 13t4 13t4 13t4 STOCK SIZE TXW 21t4 X 16 123t8 13 1t2 14 5t8 157t8 18 19 1/8 20 1t8 221t8 23 1t4 24 1t4 25 3t8 26 3t8 23t4 23t4 23t4 23t4 23t4 X X X X X 16 16 16 16 16 NOTES: 1 . All dimensions are in inches and are provided for user information only. 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440, 2525 and 2530. 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut. then lock in place. ORDERING INSTRUCTIONS: Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size . EXAMPLE: Part 6252-60-Rl0-12" INC. TF1; BERGEN-POWER PIPE SUPPORTS u 2X 18 2X19 2X19 2X20 21t4X20 21t2X 16 21t2X 16 21t2X 16 Ht' CDRS CATALOG INFORMATION SHEET PART 6252-60 DATE 9t1t2007 ffi ru CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS RESTRAINT RISER CLAMP DIRECTION OF LOADING I NOte: G 'F The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC p Temperature: 650 NO.: DS.628O DESIGN REPORT NO.: Rated Loads (lbs) lor Classes 1,2,3 & MC REV PIPE SIZE Design Condition 3t4 700 OPERANNG CONDITIONS 700 700 700 700 700 700 700 700 1 11t4 11t2 2 21t2 3 4 5 6 8 10 12 Test Condition Level A Level B Level C Level D (see Note) 700 700 700 700 700 700 931 931 931 931 931 931 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300 931 931 700 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 700 700 700 931 931 931 931 700 700 700 700 700 700 931 931 931 700 931 931 931 931 931 931 931 931 931 931 931 & bottom, mounted at 90"to each other and 450 from the vertical centerline of the clamp, supplied by others. Each pin supports the full design condition load. NOTE: This product must be used with shear lugs top equirements of the applicable o o o, l U) a J z CI TE o qKK REV I The Design Report & Design Specification Materials: N UJ Code. ffi Certification Plate: Bolts: Pin: Nuts: sA-36 SA-307 GR B 5A-6564 TYP. 630 SA-563 GR A are in accordance with ASME Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe SupPorts, lnc. Product Engineering Department Studs: Cotter pins, Washers, Retainers Exempt (NF-1 110) CONTROL REF BERGEN.POWER PIPE SUPPORTS, INC. NO. Sheet lof 1 6280 PAlt I N(,. /a\. 6280-.7 RESTRAINT RISER CLAMP + l PIPE SIZE -G L_l -.il t,, @ @ I I Gt) T + W t \to \(f) REV PIPE SIZE 3t4 1 1 1t4 1 1t2 2 21t2 3 4 5 6 8 10 12 F- o o CD c-c MIN 5 5112 6 61t2 7 8 8112 9 11 12 1t2 141t2 16 1t2 19 MAX 24 24 24 24 24 24 24 24 24 30 30 36 36 D G P 3t4 3t4 3t4 3t4 3t4 3t4 3t4 3t4 3t4 3t4 3t4 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 314 3t4 STOCK w T 1t2 4 1t2 4 4 1t2 4 1t2 4 1t2 1t2 4 1t2 4 1t2 4 1t2 4 1t2 4 4 1t2 1t2 4 1t2 1t2 4 1t2 NOTES: 1 . All dimensions are in inches and are provided for user application onlv. 2. This clamp is compatible with BPPS Parts 2015,2250,2252,2420 and 2440. 3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place. uJ f a q J g = TT o ORDERING INSTRUCTIONS: Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required. EXAMPLE: Part 6280-.7-R0-3"-C-C= 10" G lEV TFN BERGEN-POWER PIPE SUPPORTS PART 6280-.7 CDRS CATALOG INFORMATION SHEET DATE 9t1t2007 Hd fl CERTIFIED DESIGN REPORT SUMMARY lor NUCLEAR POWER PLANT STANDARD SUPPORTS RESTRAINT RISER CLAMP 0 DIRECTION OF LOADING Temperature:.$Qlf Note: The temperature shown above is for Design and Operating Gonditions. For the Test Condition (Hydro) the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DS-6280 R0 DR-6280 RO Rated Loads (lbs) lor Classes 1,2,3 & MC DESIGN SPEC NO.: DESIGN REPORT NO.: 3l F E ,l be used with shear lugs top & bottom, mounted at 90"to each other and 45 from the vertical centerline of the clamp, supplied by others. Each pin supports the full design condition load. NOTE: This product must 'equirements of the applicable o o o, f @ a J z CI (E o qKTA REV I Materials: Fr uJ Code. ffi CLOUTIER Certification Plate: Bolts: Pin: Nuts: SA-36 SA-307 GR B 54-6564 TYP. 630 5A-563 GR A The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe SuPPorts, lnc. Product Engineering DePartment Studs: Cotter pins, Washers, Retainers Exempt (NF-1 1 10) CONTROL REF BERGEN.POWER PIPE SUPPORTS, INC. Sheet l-of 1 NO. K 6280 PART NO. 6280-1.5 RESTRAINT RISER CLAMP c-c PIPE SIZE I r I ,_ I eouio oR sruDu + \ct, REV 21t2 3 4 5 6 I 10 12 14 16 l- o o o) MIN 9 10 11 12 13 1t2 15 1t2 17 1t2 20 21 23 1t2 e+ @ I c-c PIPE SIZE { r> MAX 24 24 24 26 30 30 32 34 36 38 D G P 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 5t8 5/8 5t8 5t8 5/8 5t8 5t8 5/8 5/8 5/8 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 1t2 STOCK W T 314 3t4 3t4 3t4 3t4 3t4 314 3t4 3t4 3t4 4 4 4 4 4 5 5 5 5 5 NOTES: 1 . All dimensions are in inches and are provided for user application onlv. 2. This clamp is compatible with BPPS Parts 2015,2250,2252,2420 and 2440. 3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place. r,rJ f @ I J z g (r o F ORDERING INSTRUCTIONS: Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required. EXAMPLE: Part 6280-1 .5-R0-3"-C-C= 10" \o lEV TFI; U BERGEN.POWER PIPE SUPPORTS Irdtd CDRS CATALOG INFORMATION SHEET PART 6280-1 .5 DATE 9t1t2007 rn; U CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS RESTRAINT RISER CLAMP H* DIRECTION OF LOADING I Note: Temperature: 650 'F The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f . For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. - DESIGN SPEC NO.: DESIGN REPORT NO.: DS-6280 R0 DR-6280 RO Rated Loads (lbs) for Classes 1,2,3 & Mc REV PIPE SIZE OPERATING CONDITIONS Design Condition Level A Level B 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 21t2 3 4 5 6 8 10 12 14 16 Level G 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 Level Test Gondition (see Note) D 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 5320 5320 5320 5320 5320 5320 5320 5320 5320 5320 NOTE: This product must be used with shear lugs top & bottom, mounted at 90" to each other and 45" from the vertical centerline ol the clamp, supplied by others. Each pin supports the lull design condition load. -"*ry equirements of the applicable Code. I Plate: o b Bolts: Pin: Nuts: LlJ f a L J 5A-36 SA-307 GR B 5A-6564 ryP. 630 54-563 GR A are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, lnc. Product Englneerlng Department Studs: z Itr REV The Design Report & Design Specification Materials: to Cotter pins, Washers, Retainers Exempt (NF-1110) Certilication CONTROLREFNO. BERGEN-POWER PIPE SUPPORTS, INC. 1of 1 6280 PART NO. Sheet ,,4. 6280-4 TO P${ Ii rii tf l' :1 '1_ il1il -1-il ilOTES: I. 2. Al in D i I d imens ions are imens ions are prov 3. This clamp is i nches. ded f or user cornpatible with B-P Parts 2015, 2250, 2252, 2525 and 2530. ORDERI I{G II(STRUCTIOITS : Specify Part l{o., Load Size ignet ion, Load Capac i ty Data. Sheet Revision No., Pipe Size and C-C required EXAiIPUE: Part 6280-4-nl4'6'-'-C-g=15,". Des I IOiI NOTE: Tension bolts }ISTALLAT to remove slack plus l/2 turn of the nut. lock in place. ItilCEI+ATTrIO}I PIPE sUPFlOnr GORP. DltE 11-19-E7 Then ffi CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS RESTRAINT RISER CLAMP H DIRECTION OF LOADING Temperature: 650 " F NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: 7 7 \+ DESIGN REPORT NO.: REV Design Condition PIPE SIZE 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 4 5 6 I 10 12 14 16 18 20 22 24 26 28 28 28 DS-6280 R0 DR-5280 RO Rated Loads lor Classes ,2,3 & MC OPERANNG CONDITIONS Test Condition Level A Level B Level C Level D (see Note) 7000 7000 7000 7000 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 10500 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 14000 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 9310 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 7000 NOTE: This product must be used with shear lugs top & bottom, mounted at 90'to each other and 45" from the vertical centertine of the clamp, supplied by others. Each pin supports the full design condition load. rcenrylnrs uuFrD "oto@ Code. I equirements of the applicable The Design Report & Design Specification Materials: Fr f Plate: Bolts: Pin: ) Studs: o o q) Lll a a Nuts: SA-36 SA-307 GR B SA-6564 TYP. 630 5A-563 GR A are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe SuPPorts, lnc, Product Engineering Department g = E lotter pins, Washers, Retainers Exempt (NF-1110) o REV CONTROL REF BERGEN.POWER PIPE SUPPORTS, INC. Gertification Sheet lof 1 NO. A 6280 PAft I N(,. 6280-7 RESTRAINT RISER CLAMP c-c sIzE PIPE --l I I -I T I BOLTA ORI 5TUDZ ! l* ----->1 t,, --T- @ @ I + I W i PIPE SIZE 4 6 6 IEV 5 6 8 10 12 14 16 18 20 22 24 26 28 30 36 N o r o o, uJ l a c-c MIN 141t2 16 17 20 23 25 26 29 1t2 112 1t2 1t2 31 34 36 37 1t2 40 42 44 50 MAX 25 28 30 30 36 36 36 48 48 48 48 48 50 25 23 60 D G P 1 1t2 1 1t2 1 112 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 3t4 3t4 3t4 3t4 3t4 11t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 314 3t4 3t4 3t4 314 3r4 314 314 3t4 314 3t4 STOCK W T 1 1t2 6 7 1 1t2 7 1 1t2 7 1314 7 1 3t4 7 1314 1 1t2 8 9 1 3t4 9 1314 9 1314 10 1 1t2 10 1 1t2 10 1 1t2 1 1t2 10 10 1 1t2 11 1 1t2 NOTES: 1 . All dimensions are in inches and are provided for user application onlv. 2. This clamp is compatible with BPPS Parts 2250,2252,2420,2440,2525 and 2530. 3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place. I J z ORDERING INSTRUCTIONS: Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required. G EXAMPLE: Part6280-7-R0-6"-C-C=20" g IT o G lEV ffl; BERGEN-POWER PIPE SUPPORTS Hd fl CDRS CATALOG INFORMATION SHEET PART 6280.7 DATE 9t112007 CERTIFIED DESIGN REPORT SUMMARY f*l lor llt NUCLEAR POWER PLANT STANDARD SUPPORTS I I , i:- - - r 0 rolo,,-i-_, DIRECTION OF LOADING Temperature:-.QSf I NOte: The temperature shown above is for Design and Operating Conditions. For the Test Gondition (Hydro) the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DS-6280 R0 DR-6280 RO Rated Loads (lbs) for Glasses 1,2,3 & MC DESIGN SPEC NO.: DESIGN REPORT NO.: REV Des.is.n oPERATING CONDITIONS -l l r"", condition (see Note) I I lol12000ltzoooltsgeol18000l22500l15960l lal12000lreooolt5960l18000l22500l15960l I ro I 12000 I 12000 I t5960 I 18000 I 22500 | I rz I 12000 I 12000 I 15960 I 18000 I 22500 | 15960 15960 I l;rr= .*T I tI vons*ren I a" l+lrzoooltzoooltsgeolteooolzzsooltsg0ol lsl12000lrzoooltsgeoltsoool22500l15960l I r+ | I re I tzooo I tzooo I tsgeo I teooo I rzooo I tzooo I tsgso I taooo I rzooo I tzooo | 15960 I t8000 | I rs I zzsoo zzsoo I I 22500 | tsg0o tsgoo 15960 I I I | l-.-.+ NOTE: This product must be used with shear lugs top & bottom, mounted at 90'to each other and 45 from the vertical centerline ol the clamp, supplied by others. Each pin supports the full design condition load. *tiffiT*-; r cenrry Inrs uuFrD requirements of the applicable The Design Report & Design Specification Materials: F- Plate: Bolts: Pin: Nuts: o o o, TIJ :) a a J are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at 54-36 SA-307 GR B SA-6564 TYP. 630 SA-563 GR A Bergen Power Pipe Supports, lnc, Product Engineering DePartment Studs: z a (f, o Cotter pins, Washers, Retainers Exempt (NF-1 \K.F REV Code. I Certification 1 10) CONTROL REF BERGEN.POWER PIPE SUPPORTS, INC. Sheet 1of 1 NO. A FEV. 6280 PART NO. 6280-12 RESTRAINT RISER CLAMP >t I D - Ir -G t,, l -->] -T @ @ I + W i PIPE SIZE 4 6 \(t) REV 5 6 8 10 12 14 16 18 20 22 24 26 28 30 36 F- o o o, r! f F U) c-c MIN 14112 16 17 1t2 20 1t2 23 25 1t2 26 1t2 29 31 34 36 37 40 42 44 50 112 MAX 25 28 30 30 36 36 36 48 48 48 48 48 50 25 23 60 D G P 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 112 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 7t8 3t4 3t4 314 3t4 3t4 3t4 3t4 3t4 3t4 314 3t4 314 3t4 3t4 3t4 314 STOCK T w 1 1t2 6 7 112 1 7 1 1t2 7 1 3t4 7 1 3t4 7 1 3t4 1 1t2 8 9 1 3t4 13t4 13t4 1 1t2 1 1t2 1 112 1 1t2 1 1t2 1 1t2 I 9 10 10 10 10 10 11 NOTES: 1 . All dimensions are in inches and are provided for user application onlv. 2. This clamp is compatible with BPPS Parts 2250,2252,2525 and 2530. 3. Tension bolts to remove slack plus l12turn of nut. Then lock in place. a J z Itr ORDERING INSTRUCTIONS: Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required. o G G lEV rn; fl EXAMPLE: Part6280-12-R0-6"-C-C= 20" BERGEN-POWER PIPE SUPPORTS Hd CDRS CATALOG INFORMATION SHEET PART 6280-12 DATE 911t2007 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS RESTRAINT RISER CLAMP DIRECTION OF LOADING Temperature:1Q5O '' E Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: REV PIPE SIZE 6 I 10 12 14 16 18 20 22 24 26 28 30 36 Design Condition 25000 25000 25000 25000 25000 25000 25000 25000 25000 2s000 25000 25000 25000 25000 DS-6280 R0 DR-6280 RO Rated Loads (lbs) lor Glasses 102,3 & MC OPERANNG CONDITIONS Test Condition Level A Level B Level G Level D (see Note) 25000 25000 25000 25000 37500 37500 37500 47000 47000 47000 47000 33250 25000 25000 25000 25000 33250 33250 33250 33250 33250 33250 33250 33250 33250 33250 47000 47000 47000 33250 33250 33250 33250 33250 25000 33250 25000 25000 33250 33250 33250 37500 37500 25000 25000 25000 37500 37500 37500 37500 37500 37500 33250 33250 33250 47000 47000 37500 37500 37500 47000 47000 47000 33250 33250 47000 47000 33250 33250 33250 NOTE: This product must be used with shear lugs top & bottom, mounted at 90'to each other and 45" lrom the vertical centerline ol the clamp, supplied by others. Each pin supports the full design condition load. I certify this CDRS complies with the I requirements of the applicable Code. I o o o) UJ :) U) a -J z o E o qKK REV The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Materials: N ffi I CLOUTIER Certification Plate: SA-36 Bolts: Pin: Nuts: SA-307 GR B 5A-6564 TYP. 630 SA-563 GR A Bergen Power Pipe SuPPorts, lnc. Product Engineering Department Studs: Cotter pins, Washers, Retainers Exempt (NF-1 1 10) CONTROL REF BERGEN.POWER PIPE SUPPORTS, INC. Sheet Lof 1 NO. REV. /a\ 6280 PART NO. 6280-25 RESTRAINT RISER CLAMP c-c PTPE SIZE I --T @ @ + + I W I \to s tEV r- O r o O) LrJ f U) PIPE SIZE 6 8 10 12 14 16 18 20 22 24 26 28 30 36 c-c MIN 20 1t2 23 25 27 28 31 112 112 112 112 34 36 38 1t2 40 112 42 112 45 47 53 MAX 30 35 42 42 42 48 48 48 48 D 2114 2114 2114 2114 2114 2114 2114 21t4 2114 51 21t4 60 60 60 63 2114 21t4 21t4 2114 1 1 1 1 1 1 1 1 1 1 1 1 1 1 G P 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1 1 1 1 1 1 1 1 1 1 1 1 1 1 STOCK W T 2 7 2 7 2 7 2 7 2 8 2 2 2 2 1 314 2 2 2 1 314 I 9 I 10 10 10 10 10 11 NOTES: 1 . All dimensions are in inches and are provided for user application onlv. 2. This clamp is compatible with BPPS Parts 2250,2252,2420,2440,2525 and 2530. 3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place. a J z E ORDERING INSTRUCTIONS: Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required. cc o <" G EXAMPLE: Part 6280-25-R0-8"-C-C= 28" IEV rilfl, fl BERGEN-POWER PIPE SUPPORTS Hd CDRS CATALOG INFORMATION SHEET PART 6280-25 DATE 911t2007 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS RAINT RISER CLAMP 0 DIRECTION OF LOADING Temperature: 650 " F Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DS-6280 R0 DR-6280 RO DESIGN SPEC NO.: DESIGN REPORT NO.: q9 Rated Loads (lbs) lor Classes 1,2,3 & MC REV F;T.ff;:fl:" oPERAT|NG lsl35000l . lalssoool I tz I ssooo gsooo . I I II . . r+ | ro I zo I zz I I z+ I . I I . zs I za I go I I ge I I . gsooo gsooo gsooo gsooo 35000 35000 gsooo gsooo CONDITIONS I I I I I I I I I I I Test Condition I (see 3s000 I 3s000 I 3s000 | 35000 I 35000 | 35000 | 35000 I 35000 | 35000 I 35000 I 35000 I 35000 I 35000 I 46550 I +esso I 46ss0 | 46s50 I 465s0 | 46s50 I +osso I 46550 | 46550 I 465s0 I +osso I +0sso I 46550 I 52500 I szsoo I 52s00 I 52500 | 52500 I 52500 | szsoo I 52500 | 52500 | SZSOO I szsoo I s2500 I s2500 I 65800 | 65800 | 65800 | 65800 I 65800 | 6s800 65800 65800 65800 65800 6s800 65800 65800 | | | | | I I | Note) 46550 l I 465s0 I 46550 I 465s0 | 46550 | 46550 | 46550 I 46s50 | 46550 | 46550 I 46550 I 46550 | 46550 I I n nust be used with shear lugs top & bottom, mounted at 90'to each other and 45 lrom the vertir cal centerline of the clamp, supplied by others. Each pin supports the full design condition load, NOTE: This product I certify this CDRS complies with the requirements of the applicable Code. J z 0 (E o REV I The Design Report & Design Specification Materials: F- o o b ul f a a I ffi CLOUTIER Certification Plate: Bolts: Pin: Nuts: 5A-36 SA-307 GR B 5A-6564 TYP. 630 54-563 GR A Studs: Cotter pins, Washers, Retainers Exempt (NF-!!19L are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe SuPPorts, Inc. Product Engineering DePartment CONTROL REF Sheet BERGEN-POWER PIPE SUPPORTS, INC, Lof 1 NO. A 6280 PAffT NO. 6280-35 RESTRAINT RISER CLAMP ->l t -I T-i BoLra R STUD@ OR + \lf) g tEV I 10 12 14 16 18 20 22 24 26 28 30 36 l- o o ct tIl l a a J G PIPE SIZE 6 -J ! l<I -r @ @ t,, + I W L c-c MAX 21 1t2 32 24 36 26 1t2 38 41 29 31 1t2 42 47 34 48 36 50 38 53 40 42 1t2 53 44 112 66 46 112 66 48 112 66 66 55 MIN D G P 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1t2 1 112 1 112 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 1t2 1 112 1 1t2 1 1t2 1 1t2 1 114 1 114 1 114 1 114 1 114 1 114 1 114 1114 1114 1 114 STOCK W T 2 2 2 2 2 2 2 2 2 2 11t4 21t4 1 1t4 21t4 1 1t4 2114 1 1t4 21t4 12 14 15 16 16 18 18 18 18 18 20 20 20 20 NOTES: 1 . AII dimensions are in inches and are provided for user application onlv. 2. This clamp is compatible with BPPS Parts 2250,2252,2525 and 2530. 3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place. z OR DERING INSTRUCTIONS: g (f o Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required. G EXAMPLE: Part 6280-35-R0-14"-C-C = 32" REV rF\; fl BERGEN.POWER PIPE SUPPORTS Hd CDRS CATALOG INFORMATION SHEET PART 6280-35 DATE 911t2007 GERTIFIED DESIGN REPORT SUMMARY lor NUCLEAR POWER PLANT STANDARD SUPPORTS RESTRAINT RISER CLAMP DIRECTION OF LOADING Temperature: 650 Note: 'F The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100 For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. f. DESIGN SPEC NO,: DESIGN REPORT NO.: REV PIPE SIZE DS-6280 R0 DR-6280 RO Rated Loads for ctasses 1,2.3 & MC Design Condltion Level A Level B Level C Level D (see Note) 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 90000 112800 112800 112800 112800 112800 112800 1 1 2800 112800 112800 112800 112800 112800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 79800 10 12 14 16 18 20 22 24 26 28 30 36 OPERANNG CONDII1ONS Test Condition NOTE: This product must be used with shear lugs top & bottom, mounted at 90.to each other and 45" from the vertical centerline of the clamp, supplied by others. Each pin supports the full design condition load. I certify this CDRS complies wimrn-ll requirements ol the applicable Code. I Materials: ro o b rlate: 3olts: rin: \,luts: tIl f a a J 5A-36 SA-307 GR B 5A-6564 TYP. 630 5A-563 GR A z ituds: o )otter pins, Washers, Retainers Exempt (NF-1 1 10) Itr K REV Certilication The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF. 2007 Edition and are on file at Bergen Power Pipe Supports, lnc. Product Engineering Department CONTROL REF BEBGEN-POWER PIPE SUPPORTS, INC. Sheet 1of 1 NO. 6280 rAr I ,4. NU. 6280-60 RESTRAINT RISER CLAMP c-c I I t I T I G G1 PA @ @ + I \lJ) \(f) REV fO o ct r.rJ l q PIPE SIZE 10 12 14 16 18 20 22 24 26 28 30 36 c-c MIN 29 1t2 32 33 36 38 40 43 45 1t2 47 1t2 49 1t2 51 112 58 MAX 40 44 48 49 50 51 56 56 66 66 66 68 D 2 2 2 2 2 2 2 2 2 2 2 2 3t4 3t4 3t4 3t4 3t4 3t4 3t4 3t4 3t4 3t4 3t4 3t4 G 1 11t16 1 11t16 1 1 1/16 1 1 1/16 1 11t16 1 11t16 1 11t16 1 11t16 1 11t16 1 11t16 1 11t16 1 1 1/16 STOCK W T 16 1 1t2 2 3t4 18 1 1t2 21t2 1 1t2 21t2 20 1 1t2 21t2 20 1 1t2 21t2 20 20 1 1t2 21t2 20 1 1t2 2 3t4 1 1t2 21t2 22 22 1 1t2 2 3t4 1 1t2 2 3t4 22 22 1 1t2 2 3t4 22 1 1t2 2 3t4 P NOTES: 1 . All dimensions are in inches and are provided for user application onlv. 2. This clamp is compatible with BPPS Parts 2250,2252,2421,2440,2525 and 2530. 3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place. U) J z g tE ORDERING INSTRUCTIONS: Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required. o G { G EXAMPLE: Part6280-60-R0-16"-C-C=38" lEV ffi fl BERGEN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART 6280-60 DATE 9t1t2007 tit I' CERTIFIED DESIGN REPORT SUMMARY for d E NUCLEAR POWER PLANT STANDARD SUPPORTS CUMP. R'SER PART NUMBER630/0,.,73K s .lll lll .P DIRECTION OF LOADING I I I Y Temperature: No"t Design Spec. No. DS-6300 Design Report No. DR-6300 6500F For' the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in fre Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Test Condition Operatins Conditions Level B Level G Size Design Condition 3t4 730 971 1 730 730 730 11t4 730 1112 2 21//2 Level D (see Note) 1,095 1,278 971 971 1,095 1,278 971 730 971 1,095 1,27E 971 730 730 971 1,095 1,278 971 730 730 971 1,095 1,278 971 730 730 971 1,095 1,278 971 3 730 730 971 1,095 1,278 971 4 730 730 971 1,095 1,278 971 730 971 1,095 1,278 971 1,095 1,278 971 Level A 730 5 6 730 730 971 8 730 730 971 1,095 1,278 971 t0 730 730 971 1,095 1,278 971 12 730 730 971 1,095 1,278 971 Rated Loads (lbs) for Classes 1,2,3 &MC This product must be used with shear lugs, mounted at 900 to each other and 450 from the vertical centerline of the clamp, lugs will be supplied by others. Each pin supprts the full design condition. I cenify this CDRS CONTROLREFNO. comflies with he MATERIALS requirements of the apflicable code Plate: SA-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A 6300 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: SA-193 87 Bergen Power Pipe Supports,lnc. Studs: N/A Product Engineering DePartment Exempt Cotter pins, Washers, Retainers (NF-2121) REV|St0NS A-tu/,&"fr $EAL vdhr/aglslcNED /J, Oriqinal lssue 10/27109 /3\ /1\ /i BERGEAJ POWER PIPE SUPPORTS, INC, /s\ SHEET 1 0F 1 REV. A PART N0. 6300..73 CDRS CATALOG INFORMATION SHEET RISER CLAMP . PART NUMBER 6300..73K PIN to PIN (C-C) T L r _+ G --l _1 PIN O .lll . p -1 I I W lll I -J PIPE SIZE c.c D PIN DIA. VW. LBS. (MAX C.Cl \J W 3t4 3t4 112 4 32 3t4 1t2 4 MAX 6 18 1 1t2 18 3t4 1 6112 18 1 1t2 18 3t4 1114 7 18 1 1t2 18 3t4 1112 7 1t2 18 1 112 18 3t4 24 1 31 3t4 24 1 1t2 1t2 31 1 112 32 3t4 I I 2 2112 9112 3 24 sTocK slzE T 1t2 1t2 1t2 1t2 1t2 1t2 MIN 3 3 3 3 4 4 4 101t2 24 1 1t2 5 12 30 1 1t2 49 3t4 5/8 4 13112 30 1 1t2 50 3t4 5/8 4 1 1t2 60 3t4 5/8 4 6 8 16 36 10 18112 48 1 1t2 79 3t4 5t8 4 '12 20112 48 1 1t2 81 3t4 5/8 4 NOTES: 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only. 3.) For use with BPPS parts 5130 and 5131 eyenuts. ORDERING INSTRUCTIONS : Specify: Part Number, CDRS Revision Number, Pipe Size and C-C dimension. DGMPLE: 6300-.73-R/04" C-C= 20" REVISIONS lssue 10/27109 PART BERGEN POWER PIPE SUPPORTS, 'NC' N0. 6300..73 tit r, CERTIFIED DESIGN REPORT SUMMARY for *b NUGLEAR POWER PLANT STANDARD SUPPORTS R'SER CLAMP . PART NUMBER 6300.1,35K s .lll lll .s DIRECTION OF LOADING I I I V Temperature: Nottt Design Spec. No. D96300 Design Report No. DR-6300 Size ,0l' the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Condition Level A Test Condition Operating Conditions Level C Level B {see Note) Level D 1,350 1,350 1,796 2,025 2,363 1,796 1 1,350 1,350 1,796 2,025 2,363 1,796 11t4 11t2 1,350 1,350 1,796 2,025 2,363 1,796 1,350 1,350 1,796 2,025 2,363 1,796 3//4 2 1.350 1,350 1,796 2,025 2.363 1,796 2112 1,350 1,350 1,796 2,025 2.363 1,796 3 1,350 1,350 1,796 2,025 2,363 1,796 4 1,350 1,350 1,796 2,025 2,363 1,796 5 1,350 1,350 1,796 2,025 2,363 1,796 1,350 1,350 1,796 2,025 2,363 1,796 I 1,350 1,350 1,796 2,025 2,363 1,796 10 1,350 1,350 1,796 2,025 2,363 1,796 12 1,350 1,350 1,796 2,025 2.363 1,796 6 6sooF Rated Loads (lbs) for C/asses 1,2,3 &MC This product must be used with shear lugs, mounted at 900 to each other and 450 from the vertical centerline of the clamp, lugs will be supplied by others, Each pin supports the full design condition. I CONTROL REF NO. certify this CDRS complies with the rcquirements of lhe applicable code MATERIALS Plate: 5A-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A 6300 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: SA-193 87 Bergen Power Pipe Suppods, Inc. Studs: N/A Exempt Cotter pins, Washers, Retainers (NF-2121) Product Engineering DePartment REV|SIONS etLl'Affi /il Oriqinal lssue 1 0/27109 Senr 1ru722/o7lslGNED /z\ BERGEAJ POWERPIPE SUPPORTS, NC, /3\ /n /i SHEET 1 OF 1 REv. a PART N0. 6300.1.35 lit r, CDRS CATALOG INFORMATION SHEET d b R'SER CUMP . PART NUMBER 6300-1,35K I __J G -t PIN O .il| lll . p --l I I W I I _J PIPE SIZE c-c PIN MIN ruAx 7 1 8 1114 D DIA. WT. LBS. (MAX C-C) IJ STOCK SIZE T W 24 1 1t2 34 3t4 3t4 3 24 1 1t2 34 3t4 3t4 3 8112 24 1 35 3t4 3t4 3 11t2 o 24 1 35 314 3t4 3 2 9112 24 1 35 3t4 314 4 2112 101t2 36 1 67 314 3t4 4 3 11 36 1 1t2 1t2 1t2 1t2 1t2 67 3t4 3t4 4 4 121t2 36 1 1t2 68 3t4 314 4 5 14 36 1 1t2 70 3t4 3t4 4 1 1t2 71 3t4 314 4 36 1 1t2 73 314 4 48 1 1t2 119 314 3t4 3t4 48 1 1t2 122 314 3t4 4 3t4 6 I 10 12 15 16 18 112 21 36 4 NOTES: 1.) All dimensions are in inches. 2,) Dimensions are provided for user application only' 3.) For use with BPPS parts 5130 and 5131 eyenuts. ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, Pipe Size and GC dimension. E)(AMPLE: 6300-1.35-R/0-4' C-C = 20" REVISIONS /r\ Oriqinal lssue i,r\ /z\ 1 0/27109 /t\ /il /il BERGEN POWER PIPE SUPPORTS, INC. SHEETl OF 1 REV. A PART N0. 6300.1.35 tit f' CERTIFIED DESIGN REPORT SUMMARY for A t NUCLEAR POWER PLANT STANDARD SUPPORTS R'SER CUMP . PART NUMBER 6300.3,23K s .lll DIRECTION OF LOADING P il|. I I I Temperature: Nottt Design Spec. No. D96300 Design Report No. DR-6300 For. the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown forthe Operating Condition. Size Design Condition 2112 3,230 3,230 3 3,230 3,230 4 3,230 3,230 5 3,230 3,230 Level A Operatins Conditions Level B Level C 4,845 4,296 Level D Test Condition (see Notel 5,653 4,296 4,845 5,653 4,296 4,296 4,845 5,653 4,296 4.296 4,845 5,653 4,296 4,296 6 3.230 3,230 4.296 4,845 5,653 4,296 8 3,230 3,230 4,296 4.U5 5,653 4,296 10 3,230 3,230 4,296 4,945 5,653 4,296 12 3,230 3,230 4,296 4,845 5,653 4,296 3,230 4,296 4,845 5,653 4,296 3,230 4,296 4,845 5,653 4,296 14 16 6500F 3,230 3.230 Rated loads (bs) for C/asses 1,2,3 & MC This product must be used with shear lugs, mounted at 900 to each other and 450 from the vertical centerline of the clamp, lugs will be supplied by others. Each pin supports the full design condition, I certify this CDRS complies with CONTROLREFNO. fie MATERIALS rcquirements of the applicable code Plate: SA-36 Bolts: SA-307 Gr B Nuts: 5A-563 Gr A 6300 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: SA-193 87 Bergen Pawer Pipe Sup ports, lnc. Studs: N/A ExempL Cotter pins, Washers, Retainers (NF-2121) Product Engineering Depailment REVISIONS /o\ Oriqinal lssue 10/27109 A SEAL Va/L2/ot ISIGNED /t\ BERGEfV POWER PIPE SUPPORTS, INC, /s\ /r\ /t SHEETl OF 1 REV. A PART N0. 6300'3.23 Jr,,J dT, CDRS CATALOG INFORMATION SHEET t R'SER CLAMP . PART NUMBER 6300.3.23K PIN to PIN (C-C) L J- _l u -t PIN O .il| lll . I p I W I __l PIPE SIZE c.c PIN D IJ STOCK SIZE MIN MAX T W 21t2 11112 36 1 3t4 7t8 1 6 3 121t2 36 1 3t4 1118 1 6 4 14 36 1 3t4 1 6 5 15 36 I 3t4 1 6 6 161t2 36 1 3t4 1 6 8 18112 36 1 3t4 11t8 11t8 11t8 11t8 11t8 1 6 6 DIA. 211t2 48 1 3t4 24 48 1 3t4 1118 11t4 11t4 14 25 60 1 3t4 11tB 1 1t4 6 16 27 60 1 3t4 1 1t8 11t4 6 10 12 NOTES: 6 inches. : 1.) All dimensions are in 2.) Dimensions are provided for user application only. 3.) For use with BPPS parts 5130 and 5131 eyenuts. ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, Pipe Size and C-C dimension. E)(AMPLE: 6300-3.23-R/0-4" C-C = 20" REVISIONS vr /^ /r\ /i A BERG EN POWER PIPE SUPPORTS, SHEET 1 'NC, 0F 1 REV. A PART NO. 6300-3.23 tit*T, CERTIFIED DESIGN REPORT SUMMARY for H NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE STMP . PART NUMBER 6UO DIRECTION OF LOADING Temperature: *ottt Design Spec. No. DS-6440 Design Report No. DR-6440 Size 4000F For. the test condition (Hydro) the maximum temperature is 1000F, For higher temperatures in the Test Condition, use Level B loads up to the temperature showrt for the Operating Condition, Design Condition Level A Operating Gonditions Level C Level B Level D Test Condition (see Note) 1,689 1t2 1,270 1,270 1.689 1.905 2.386 314 1.045 1,045 1,390 1.568 1.964 1,390 850 850 1,131 1,275 1,597 1.131 2,265 2,265 3,012 3,398 4,256 3,012 2,015 2,015 2,680 3,023 3,786 2,680 2 1,620 1,620 2,430 3,0M 2,155 2112 2,385 2,385 2,155 3,172 3,578 4,481 3,172 3 2,630 2,630 3.498 3,945 4.942 3,498 4 2,060 2,060 3,090 3,871 2,740 5 2,095 2,095 2,740 2,796 3,143 3,937 2,786 6 2,115 2,115 2,813 3,173 3,974 2,813 8 1,630 1,630 2,168 2,M5 3,063 2,168 10 2,730 2,730 3.631 4.095 5,130 3,631 12 3,320 3,320 4,416 4.980 6.238 4.416 1 11t4 1112 Ratedloads (lbs) for Classes 1,2,3 & MC CONTROL REF I certify this CDRS complies with the MATERIALS requkements of the applicable code Plate: 5A-36 Bolts: N/A Nuts: N/A Pin: N/A NO. 6440 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Bergen Power Pipe Supporfs Studs: N/A , lnc. Product Engineering Department Exempt N/A REV|S|ONS f,n*K,e/e sEat lq2z/o? /d\ I Oriqinal lssue 1 0i27l09 lslGNED /z\ BERGETV POWERPIPE SUPPORTS, INC. /t /t /i SHEET 1 OF r REv. a PARTNO. 6440 CDRS CATALOG INFORMATION SHEET PIPE STRAP . PART NUMBER 6440 I I r-_==l PIPE SIZE A 1t2 I 3/i4 1 1114 1112 1 3t16 1 7t16 113t16 2 2 2 112 21//2 3 B T W 29t32 1t4 2 1 1t8 1t4 2 1 1t4 2 125t32 131t32 3/8 3 3t8 3 2 3/8 3 3/8 7116 215116 1t2 3 1t2 4 1t2 4 112 5 1t2 6 3 5/8 4 4 5 s 11116 3 9/16 4 9t16 5 5/8 6 6 314 611116 8 B 314 8 11/16 112 6 718 10 13/16 5/8 I 718 1213116 3t4 8 3 10 12 10 12 518 NOTES: 1.) All dimensions are in inches. 2,) Dimensions are provided for user application only' 3.) A full penetration weld on both sides can be used in lieu of a fillet weld. ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size. E/.AMPLE: 6440-R/0-4" al lssue 10127109 BERG EN POWER PIPE SUPPORTS, INC, tit r, CERTIFIED DESIGN REPORT SUMMARY for N H NUCLEAR POWER PLANT STANDARD SUPPORTS PIPE STRAP. PART NUMBER644f DIRECTION OF LOADING Temperature: 4000F Nott' Design Spec. No. DS-6440 Design Report No. DR-6440 Size Fo, the test condiilon (Hydro)the maximum temperature is 1000F, For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Design Condition Level A Test Condition Operatinq Gonditions Level C Level B (see Note) Level D 1//2 847 847 1,127 1,271 1,694 847 3t4 697 697 927 1,046 1,394 697 567 567 7il 85'l 1,134 567 1114 1.510 1,510 2,008 2,265 3,020 1,510 11t2 1,343 1,343 1,786 2,015 2,686 1,343 1,080 1,080 1,436 1,620 2,160 1,080 21t2 1,590 1,590 2,115 2,385 3,180 1,590 3 1,753 1,753 2,331 2,630 3,506 1,753 4 1,373 1,373 1,826 2,060 2,746 1,373 1 2 5 1,397 1,397 1,858 2,096 2,794 1,397 6 1,410 1,410 1,875 2,115 2,820 1,410 8 1,087 1,087 1,446 1,631 2,174 1,087 10 1,820 1,820 2,421 2,730 3,640 1.820 12 2,213 2,213 2.943 3,320 4,426 2,213 Rated Loads ilbd for C/asses 1,2,3 &MC I certify this CDRS comflies with CONTROLREFNO. $e MATERIALS rcquirements of the applicable code Plate: SA-240 TYP 304 Bolts: N/A Nuts: N/A 6441 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: N/A Bergen Power Pipe Suppods, lnc. Studs: N/A Product Engineering Department Exempt N/A REVISIONS t*h4.M.6 SEAI lp/z2/al lslGNED /o\ Orioinal lssue 10/27109 /i /I BERGEfV POWERPIPE SUPPORTS, INC, /3\ /\ /i SHEET I OF 1 REV. A PART NO, 6U1 titr, CDRS CATALOG INFORMATION SHEET d PIPE SIMP . PART NUMBER644| l yyJ 1 11//4 11/,2 2 1t4 ll 1t4 2 1 3/8 1t4 2 113t16 125t32 3/8 3 2 131132 3/8 3 112 2 7t16 3/8 3 3 215t16 1t2 3 3 9/16 4 9t16 5 5/8 1t2 4 1t2 4 112 5 3/4 611t16 1t2 6 3/4 I 2 4 5 511t16 I 10 12 29t32 1t8 3 4 6 W 1 1 21/,2 3 T 1 3/16 1 7116 11,2 314 B A PIPE SIZE 6 8 10 12 5/B 5/8 112 6 718 10 13/16 5/8 8 718 1213116 3t4 I 11/16 I 1.) All dimensions are ih inches. 2.) Dimensions are provided for user application only. 3.) A full penetration weld on both sides can be used in lieu of a fillet weld. ORDERING INSTRUCTIONS : Specify: Part Number, CDRS Revision Number, and Pipe Size. EMMPLE: 6441-R/0-4" REVISIONS /il Oriqinal lssue 1 0/27109 ii /N A /) BERGEN POWER PIPE SUPPORIS, INC. SHEET 1 OF 1 REV. A PARTNO. 6441 titf' CERTIFIED DESIGN REPORT SUMMARY for # a NUCLEAR POWER PLANT STANDARD SUPPORTS . LONG TANGENT U.BOLT Condition PART NUMBER 6500 I DIRECTION OF LOADING DIRECTION OF LOADING .: I Temperature: 6500F I Nottt Design Spec. No. DS-6500 Design Report No. DR-6500 Size Fol. the test condition (Hydro) the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shoum for the Operating Condition. I Level A 600 240 690 210 Cond.ll 112 600 240 3//4 690 210 1 1,070 150 1.070 11t4 11t2 1,290 160 1,290 1,150 130 Test Condition Operating Gonditions Level B Level G Desiqn Condition Cond. (see Note) Level D 790 310 900 360 1,200 480 790 910 270 1,030 310 1,380 420 910 270 150 1,420 200 1,600 220 2,140 300 1,420 200 160 1.710 210 1,930 240 2,580 320 1,710 210 310 ,150 1,170 130 1.530 170 1,720 190 2,300 260 1,530 170 120 1,550 160 1,750 180 2,340 240 1,550 160 220 1 2 1,170 120 21//2 2,010 170 2,010 170 2,670 220 3,010 250 4,020 340 2,670 3 2,920 140 2,920 140 3,880 180 4,390 210 5,840 280 3,880 180 31t2 1,850 120 1,850 120 2,460 160 2,770 180 3,700 240 2,460 160 4 3,040 110 3,040 110 4.040 140 4,560 160 6,080 220 4,040 140 5 2,830 90 2,830 90 3,760 120 4,240 130 5,660 180 3,760 120 6 4,1 30 150 4,130 150 5,490 200 6.190 220 8,260 300 5,490 200 Rated Loads (lbs) for Classes 1,2,3 &MC Loads for Condition I are listed first, Condition For simultaneous loading: Condition I ll are listed second. Load .@ ConditionlAllowable lcertify this CDRS comdies wifi ConditionllAllowable CONTROL REF NO. fie MATERIALS requirements of the applicable code Plate: N/A U-Bolt 5A-36, A-108 1018 CW (CC N-249) 6500 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Nuts: 5A-563 Gr A Pin: N/A Studs: N/A Bergen Power Pipe Suppodq lnc. Product Engineering Department Exempl N/A REVISIONS /; {,4.>/,Mr.ffi /r\ $EAL Va/lt/ag lslcNED Orioinal lssue 1 0/27109 /) BERGEAJ POWER PIPE SUPPORTS, INC, /J /t /5\ SHEET 1 OF 2 REV. A PART NO. 6500 CERTIFIED DESIGN REPORT SUMMARY ti7 ,, for d b NUCLEAR POWER PLANT STANDARD SUPPORTS LO'VG IA'VGE VT U.BOLT . PART NUMBER 6500 Plate Supplied by Others Condition I DIRECTION OF LOADING DIRECTION OF LOADING I Temperature: 6500F I Nottt Design Spec. No, D96500 Design Report No. DR-6500 Fo, the test condition (Hydro)the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition, Detisn Condition I Cond.ll Size Test Condition Operating Conditions Level B Level C Level A Cond. Level (see Note) D I 6,490 120 6,490 120 8,630 160 9,730 180 12,980 240 8,630 160 10 9,280 180 9,280 180 12,340 230 13,920 270 18,560 360 12,340 230 370 12 12,170 280 12.170 280 1 6,1 80 370 18,250 420 24,340 560 16,180 14 12,550 250 12,550 250 16,690 330 18,820 340 25,100 500 16,690 330 16 13,370 200 13,370 200 17,780 260 20,050 300 26,740 400 17,780 260 18 12,170 250 12,170 250 16,180 330 18.250 370 24,340 500 16,180 330 20 14,660 260 14,660 260 19,490 340 21,990 390 29.320 520 19,490 340 19,390 340 25,860 460 17.190 300 24 12,930 230 12,930 230 17,190 300 15,350 190 20,410 250 23,020 280 30,700 380 20,410 250 180 21,080 230 23,770 270 31,700 360 21,080 230 26 15,350 190 28 15.850 180 15,850 30 15,790 130 15,790 130 21.000 170 23,680 190 31,580 260 21,000 170 36 12,070 150 12,070 150 16,050 200 18.100 220 24,140 300 16,050 200 Rated loads (lbs) for Classes 1,2,3 & MC Loads for Condition I are listed first, Condition ll are listed second. Forsimultaneous I certify this CDRS complies with rcquirements of the applicable loading: Condition I Load ConditionlAllowable^ @ ConditionllAllowable MATERIALS Plate: N/A U-Bolt SA-36, A-108 1018 CW (CC N-249) Nuts: 5A-563 GrA Pin: N/A See Sheet I NO. cot{TRoL REF he ode 6500 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Bergen Power Pipe Supports,lnc, Studs: N/A Product Engineering Department Exempt N/A REVISIONS /il A Orioinal lssue 10/27109 I ISIGNED /i BERGEfV POWER PIPE SUPPORTS, INC, SEAL /3\ 4\ /t SHEET ZOF 2 REv. a PART NO. 6500 JJ,rJ *f, - CDRS CATALOG INFORMATION SHEET LONG TANGETVT U.BOLT . PART NUMBER 6500 PIPE c srzE 1t2 A B 3/8 15/16 3t4 3/8 1118 3/8 1 3/8 3/8 1 11t4 1 5t16 13t4 3 3 5/8 2718 3 3t4 3 3 3 2314 3/8 2 2 3/8 2 7t16 2112 112 215t16 213t16 3 7t16 3 1t2 3 9/16 4 1t16 3112 1t2 4 1t16 4 9t16 4 4 9/16 E 1t16 5 1t2 1t2 6 5t16 4 3 41t4 41t2 3 3/8 3 3i8 6 1/8 5 3 3/8 s/8 6 3/4 7 3/8 6 1/8 3 3i4 I 5/8 I I 7 1t8 33t4 10 314 115t8 8 3/8 12 7t8 7t8 7t8 107t8 127t8 141t8 13314 I 15 10114 16 1/8 17 11 114 41t4 41t4 41t4 18118 19 1/8 12518 4 3t4 21 1t8 13 5/8 4 314 251t8 15 5/8 43t4 27 1t8 16 5/8 4314 4314 I I 14 I 16 -J 314 5t16 5 5/8 ---1 i 21t4 2 2 3 5/8 2518 1112 tri 21t2 11t2 13t4 21t8 2318 I L D 3/4 3/B 5/8 4 18 1 20 1 24 1 26 1 201t8 241t8 261t8 28 1 28118 291t8 17 5t8 30 1 30 1/8 31 1/8 18 5/8 43t4 36 1 361/8 37 1t8 21s18 4 314 NOTES: t.; nll dimensions are in inches. 2.) Dimensions are provided for user application only. 3.) When using as a Guide (Condition ll), upset threads after installation per NF-4725. 4.) lVtren using U-Bolt sizes 1/2" through 1-112" as a Guide (Condition ll). A spacer, supplied by others, is recommended between the pipe and supporting member, tack welded in place. Spacer = 114" xll{." x 1" lg. ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size' D(AMPLE: 6500-Rl0-5" REVISIONS Al0rlqinal lssue /1\ /z\ 10/27109 /) /; /i BERGFN POWER PIPE SUPPORIS, INC. SHEETl OF 1 REV. A PART NO. 6500 ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) tit L CERTIFIED DESIGN REPORT SUMMARY for d b NUCLEAR POWER PLANT STANDARD SUPPORTS . TANGENT U.BOLT TOTVG Condition PART NUMBER 6502 I DIRECTION OF LOADING DIRECTION OF LOADING I <---_---> TemPerature: I No"t Design Spec. No. DS-6500 Design Report No. DR-6502 6500F Fo, the test condition (Hydro) the maximum temperature is 100oF. For higher temperatures in the Test Condition, use Level B loads up to the temperature shou'n for the Operating Condition. Test Condition (see Note) 1t2 1,340 170 1,340 170 Operating Conditions Level C Level B 250 220 2.010 1,780 2,680 340 1,780 3/,4 1,530 90 1.530 90 2,030 120 2,29A 130 3,060 180 2,030 120 1 1,360 80 1,360 80 1,800 100 2,040 120 2.720 160 1,800 100 11/i4 2,850 360 2,850 360 3,790 470 4,270 540 5.700 724 3,790 470 11//2 2,540 310 2,540 310 3,370 410 3,810 460 5,080 620 3.370 410 3,450 280 Size Desisn Condition Cond.ll Cond. I Level A Level D 220 2 2,600 210 2,600 210 3,450 280 3,900 310 5,200 420 2',112 4,430 420 4,430 424 5,890 550 6,640 630 8,860 840 5,890 550 9,690 400 12,920 540 8,590 350 3 6,460 270 6,460 270 8,590 350 31i/2 4 4,070 260 4,070 260 5,410 340 6,100 390 8,140 520 5,410 340 6,710 220 6,710 220 8.920 10,060 330 13,420 440 8,920 290 5 6,260 210 6,260 210 8,320 290 270 9,390 310 12,520 420 8,320 270 6 9,130 340 9,1 30 340 12,140 450 13.690 510 18,260 680 12,140 450 Rated Loads (lbs) for Classes 1,2,3 &MC Loads for Condition I are listed first, Condition ll are listed second. For simultaneous loading: Condition I Condition I I certify ihis CDRS complies wiih Load * Allowable Condition ll Load CONTROL REF NO, fie MATERIALS mquirements ol the applicabh oode Plate: N/A U-Bolt: 5 Condition ll Allowable 6502 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection sA-193 87 NF 2007 Edition and are on file at: Nuts: SA-194 2H Pin: N/A Bergen Power Ptpe Sup ports, lnc. Studs: N/A Product Engineering Department Exempt N/A REV|SIONS fu;*K,&77 $epg \rc,ltz/of ISIGNED /d, Oriqinal lssue 1 0/27109 /i BERGEN POWER PIPE SUPPORTS, INC. /i /t /) SHEET |OF 2 REV. A PART NO. 6502 tit*r, CERTIFIED DESIGN REPORT SUMMARY for b NUGLEAR POWER PLANT STANDARD SUPPORTS . LONG TA'VGE VT U.BOLT PART NUMBER 6502 DIRECTION OF LOADING DIRECTION OF LOADING -e I Temperature: 6500F I nott' Design Spec. No. DS-6500 Design Report No. DR-6502 Fol. the test condition (Hydro)the maximum temperature is 1000F. For higher temperatures in the Test Condition, use Level B loads up to the temperature shown for the Operating Condition. Cond. I Test Gondition (see Note) Operating Gonditions DesiEn Condition Size Level A Cond.ll Level D Level C Level B 8 14,520 270 14,520 270 19,310 350 21,780 400 29,040 540 19,310 350 10 20,610 400 20,610 400 27,410 530 30,910 600 41,220 800 27,410 530 12 27j60 630 27,160 630 36,120 830 40.740 940 36,120 830 14 27.860 560 27,860 560 37,050 740 41.790 840 54,320 1,260 55,720 1,120 37,050 740 16 29,620 440 29,620 440 39,390 580 44,430 660 59,240 880 39,390 580 18 26,820 570 26,820 570 35,670 750 40,230 850 53,640 1,140 35,670 750 20 32,380 580 32.380 580 43,060 770 48,570 870 64,760 1,160 43,060 770 1,040 37,770 690 24 28.400 s20 28,400 520 37,770 690 42.600 780 56,800 51.130 640 68,180 860 45,340 570 530 26 34,090 430 34,090 430 45,340 570 28 34,950 400 34,950 400 46,480 530 52,420 600 69,900 800 46,480 46,130 390 52,030 450 69,380 600 46,130 390 35,470 450 40,000 sl0 53,340 680 35,470 450 30 36 34,690 300 34,690 300 26,670 340 26,670 340 Rated loads (lbs) for C/asses 1,2,3 & MC Loads for Condition I are listed first, Condition ll are listed second. gondition I Condition ll Load For simultaneous Load loading: * ConditionlAllounable I certify this CDRS complies ConditionllAllowable CONTROL REF NO, wifi he MATERIALS requirements of the applicable code Plate: N/A U-Bolt SA-193 87 Nuts: SA-194 2H The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF 2007 Edition and are on file at: Pin: N/A See Sheet 1 6502 Bergen Power Pipe SuPPorts, lnc. Studs: N/A Product Engineering DePartment Exempt N/A REV|StONS io\ Oriqinal lssue 10/27109 /1\ I ISIGNED /i BERGEIV POWER PIPE SUPPORTS, INC, SEAL /3\ /i /il SHEET ?OF 2 REV. A PART NO. 6502 tit ,, CDRS CATALOG INFORMATION SHEET d E . LONG IANGENT U.BOLT PART NUT|f/BER 6502 PIPE c A B 112 1t4 15/16 314 1t4 11t8 1 3/8 2 5t8 23t4 27t8 SIZE 1 3/16 1 1t4 1 3/8 1 5/8 1114 3/8 13t4 11t2 3/8 2 D E 2112 21t4 23t8 23t8 3 21t2 21t2 2 3/8 21t2 21t8 23t8 27t8 31t4 21t2 2112 1t2 3 31t2 3 3t4 3 3 1t2 3 5/8 41t8 4 3 3112 1t2 4 5/8 41t4 3 1t2 41t8 4 5t8 5 1/8 4112 3 5 1t2 5 5i8 6 1t8 5 3 6 5/8 6 3t4 7 3t8 61/8 33t4 33t4 4 I E I 5i8 8 3t4 9 3t8 71t8 10 314 115t8 8 3/8 12 7t8 13314 I 14 7tB 107t8 127t8 141t8 15 10114 16 7t8 16 1/8 17 111t4 18 1/8 19 1/8 12518 21 1t8 13 5/8 25118 15 5/8 27 16 5/8 5/8 4 41t4 41t4 41t4 4 3t4 4 314 18 1 20 1 24 1 201t8 241t8 26 I 26118 28 1 281t8 291t8 17 30 1 30 1/8 31 118 18 5/8 43t4 43t4 43t4 43t4 36 1 36 1/8 37 1t8 215t8 4 3t4 118 518 NOTES: 1.) All dimensions are in inches. 2.) Dimensions are provided for user application only. 3.) When using as a Guide (Condition ll), upset threads after installation per NF-4725. 4.)When using U-Boltsize 112" as a Guide (Condition ll). Jam nuts are required on top of the steel, instead of full nuts, , ORDERING INSTRUCTIONS: Specify: Part Number, CDRS Revision Number, and Pipe Size. E)(AMPLE: 6502-FU0-5" REVISIONS /il r\ /2' 1Orlqinal lssue 10/27109 /t' /r\ /t BERGE,\J POWER PIPE SUPPORTS, INC. SHEET 1 0F 1 REV. A PART NO. 6502 ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) LOAD CAPACITY DATA SHEET for NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS U.BOLT RESTRAINT CLAMP l LOAD -+* ,l' 100 (ryP) I ,\l.. ! F il -,(. d \) b DESIGNED BY: DIRECTION OF LOADING TEMPERATURE:650 Load Rating f LOAD RATTNG (LBS) for Glass 1,2,3 & MC SIZE .{9 -p s EUJ> 1t2" 314" 1 N ? I 1 114 1 112 2 DESIGN CONDITION OPERATING CONDITIONS LEVEL D LEVEL C EMERGENCY FAULTED LEVEL A LEVEL B UPSET NORMAL 700 700 700 700 700 700 700 700 700 700 930 930 930 930 930 930 700 700 TEST CONDITION 400 400 1 400 1 400 1 400 1 400 050 050 1 050 1 050 1 050 1 050 1 1 1 1 931 931 931 931 931 931 CD ul J (n F o o J o uJ a l.U E o z tr. ]U lIJ o o O lu F o 0f l< EIII> H* dE (ll - gb E, o NOTE: I certify that this LCDS complies with the requirements of the applicable code. Materials: I lg-t wts rvr tralc Pr 9vr )tate: sA-36 perlormed in accordance with: ASME BPVC SECTION lll, 5A-564 TYPE 630 J-Bolt: 5A-36 \uts: SA-307 GR B n ,/1 \ )in: SUBSECTION NF COMPONENT SUPPORTS 2OO7 EditiON and are on file at: BERGEN.POWER PIPE SUPPORTS, INC. Product Englneerlng DePartment Sotter pins, Washers, Retainers Exempt (NF-1110) Il|f, ?LE ]ONTROLREF. NO. BERcEN-powER ptpE s.tppoars, tNc. Sheet LOAD CAPACITY DATA SHEET _!_ol1 6525 A REV. PART NO 6525-0.7 R G l i-- SWIN6 RADIUS TORQUE l ---I ffi I /i7>' k fftl-ttt loot'vp \/ L \$\' 4 E + -I li Iq t \ \ () )' -\,- -T- 6 I A b 3 11/16 NOTES: 1. All dimensions are in inches. 2. Minimum sprino rate by test = 500 Kips/in. 3. This assembly to be used with Parts 2015,2250,2252 &2440. 3. Dimensions are provided for user application only. ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation. EXAMPLE: 6525-.7'R 11' 1" EERGEN-POWER PIPE SUPPORTS INC. CATALOG INFORMATION SHEET PART 6525-0.7 DATE 91112007 LOAD CAPACITY DATA SHEET for NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS U.BOLT RESTRAINT CLAMP A LOAD ;f_ lOoorpl \ i '\.{( -\ ft X (' \: b DIRECTION OF LOADING TEMPERATURE:650 Load Rating ESIGNED BY: f LOAD RATTNG (LBS) for Glass 1,2,3 & MC srzE € -s, sr EIU> 112' 314" 1 1 1/4 F* o I I 1 112 2 DESIGN CONDITION OPERATING CONDITIONS LEVEL C LEVEL D LEVEL B EMERGENCY FAULTED UPSET LEVEL A NORMAL 2000 2000 2000 2000 2000 2000 500 1 500 1 500 1 500 1 500 1 500 500 1 500 1 500 1 500 1 500 1 500 1 1 2250 2250 2250 2250 2250 2250 TEST CONDITION 995 995 1 995 1 995 1 995 1 995 3000 3000 3000 3000 3000 1 1 3000 ct) uJ J m F o o J o lIJ U) lU E o z E UJ lrJ o o O UJ F o (L f NOTE: I certify that this LCDS complies with the requirements of the applicable code. gb tr o Nuts: SA-307 ffi perrormed in SUBSECTION NF COMPONENT SUPPORTS 2OO7 EditiON and are on llle at: "ccoro"n""?;fft'ffi;i"-Ji.ttot,,,, 5A-564 TYPE 630 7\ U-Bolt: SA-36 EIJI> 6E A- Plate: 5A-36 Pin: G H* Materials: BENGEN-POWER PIPE SUPPORTS, INC. GR B Product Engineerlng Department CLOUTIER Ootter pins, Washers, Retainers Exempt (NF-1110) ms HJ - 3ONTROLREF. BERGEN.POWER PIPE SUPPORTS, INC. LOAD CAPACITY DATA SHEET NO. Sheet 1ol1 6525 A REV. t ART NO 6525-1.5 R :I G I f ffi ffi-ttt' P \ loornp: \t \K. r.J( E + t' n L T n I 7) / 5WIN6 RADIU5 TORQUE \ \ /) (/ )t It b l> 3 13/16 3 15/16 NOTES: 1. All dimensions are in inches. 2. Minimum soring rate by test = 500 Kips/in. 3. This assembly to be used with Parts 2015,2250,2252 & 2440. 3. Dimensions are provided for user application only. ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation. EXAMPLE: 6525-.1 .5-R/1- 1" BER6EN.POWER PIPE SUPPORTS INC. CATALOG INFORMATION SHEET PART DATE 6525-1 .5 91112007 LOAD CAPACITY DATA SHEET lor NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS -tr B R E I I b \., DIRECTION OF LOADING SIGNED BY: SIZE G al 'ltz" EUJ> 314" 1 l- o I I 1 114 1 112 2 TEMPERATURE:650 Load Rating DESIGN CONDITION LOAD RATTNG (LBS) for Class 1,2,3 & MC OPERATING CONDITIONS LEVEL D LEVEL C LEVEL A B LEVEL EMERGENCY FAULTED NORMAL UPSET 700 700 700 700 700 700 700 700 700 700 700 700 930 930 930 930 930 930 TEST CONDITION 931 1400 1400 1400 1400 1 400 1 400 050 050 1 050 1 050 1 050 1 050 1 1 f 931 931 931 931 931 CD lrJ J dt F o o J o lu I lIJ tr o z E UJ IU o o O ]u F o tL f EIJI> IJJ f@ o, gS o Materials: tif.Ti"tto",t,, Plate: 5A-36 Pin: 5A-564 TYPE 630 U-Bolt: 5A-36 Nuts: SA-307 GR B perrormed tn accordancffiffiti* SUBSECTION NF COMPONENT SUPPORTS 2007 Editlon and are on fite at: n ,/1 \ BERGEN.POWER PIPE SUPPORTS, INC. Product Engineering DePartment Cr) aa U'< E, NOTE: I certify that this LCDS complies with the requirements of the applicable code. Cotter pins, Washers, Retainers Exempt (NF-1110) IH; :1 OONTROLREF. BERcEN-powER ptpE suPPoRTs, tNc. LoAD cAPActrY DATA sHEET NO. 6525 Sheet -!ot 1 REV. ,/\ ,ART NO 6526-0.7 R 5WIN6 RADIU5 lOotrvp> i- {- TORQUE /'.\ 15 FT-LBS. !4 ^1 (T/P) I i 1 -'-\ { \l-/, \\\; ///// , 3 11/16 NOTES: 1. All dimensions are in inches. 2. Minimum sprinq rate bv test = 500 Kips/in. 3. This assembly to be used with Parts2015, 2250,2252 &2440. 3. Dimensions are provided for user application only. ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation. EXAMPLE: 6526-.7-R 11- 1" BERGEN.POWER PIPE SUPPORTS INC. CATALOG INFORMATION SHEET PART 6526-0.7 DATE 9t112007 LOAD CAPACITY DATA SHEET lor NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS ,l LOAD V -fr tR ,/ /t 5 1 ..\ I i--T-, \ I I ( b "-2 DIRECTION OF LOADING TEMPERATURE:650 Load Rating SIGNED BY: T LOAD RATTNG (LBS) for Class 1,2,3 & MC stzE 6 EUJ> 1tz" 314" 1 F- o t I 1 114 1 112 2 DESIGN CONDITION LEVEL A 500 1 500 1 500 1 500 1 500 1 500 150t) 1 500 1 500 1 500 1 500 1 500 1 OPERATING CONDITIONS LEVEL D LEVEL C LEVEL B EMERGENCY FAULTED UPSET NORMAL 2000 2000 2000 2000 2000 2000 2250 2250 2250 2250 2250 2250 TEST CONDITION 995 995 1 995 1 995 1 995 1 995 3000 3000 1 1 3000 3000 3000 3000 CD IIJ J d) F o o J o IJJ 9, ]JJ E o z E lrJ ]U o o O Lu F o L l EIJJ> IJJ Materials: )late: )in: 5A-36 S4-564 TYPE 630 J-Bolt: SA-36 \uts: Stress calculations or tesl data for this product were perlormed ln accordance with: ASME BPVC SECTION lll, SUBSECTION NF COMPONENT SUPPORTS 2007 Editlon n O) ES E, and are on lile at: ,/1\ BERGEN.POWER PIPE SUPPORTS, INC. SA-307 GR B Product Engineerlng Department Cr) f@ aa (r) < o NOTE: I certify that this LCDS complies with the requirements of the applicable code. Sotter pins, Washers, Retainers Exempl(l',1!- l!_lQ) sONTROLREF. BERGEN-POWER PIPE SUPPORTS, INC. LOAD CAPACITY DATA SHEET NO. 6525 Sheet 1of 1 A REV. 'ART NO 6526-1.5 R 5WIN6 RADIUS lQot"yp> l l . /'&\ I wj( / 1, { ---\ \l-/, \\\; , --l/// 3 13/16 3 15/16 NOTES: 1. All dimensions are in inches. 2. Minimum sprino rate bv test = 500 Kips/in. 3. This assembly to be used with Parts2015,2250,2252 &2440. 3. Dimensions are provided for user application only. ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation. EXAMPLE: 6526-1.5-R/1- 1" TERGEN-POWER PIPE SUPPOBTS INC. CATALOG INFORMATION SHEET PART DATE 6526-1 .5 9t112007 CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS U.BOLT CRADLE GUIDE DIRECTION OF LOADING Temperature-: Note: 600'F The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: DS-8460 R0 DR-8460 R0 Rated Loads (lbs) for Classes 1,2,3 & MC F lE' v PIPE SIZE Condition Level A Level B Level C Level 10000 10000 10000 10000 15000 15000 15000 15000 15000 20000 20000 20000 25000 25000 10000 10000 10000 10000 15000 15000 15000 15000 15000 20000 20000 20000 25000 25000 13300 13300 13300 13300 19950 19950 19950 19950 19950 26600 26600 26600 33250 33250 15000 15000 15000 15000 20000 20000 20000 20000 30000 30000 30000 30000 30000 40000 40000 40000 50000 50000 2 2112 3 4 5 6 8 10 12 14 16 18 20 24 rcenrymrs uuHD OPERATING CONDITIONS FL Design 22500 22500 22500 22500 22500 30000 30000 30000 37500 37500 Test D Condltion (see Note) 13300 13300 13300 13300 19950 19950 19950 19950 19950 26600 26600 26600 33250 33250 "otp@ equirements ol the applicable Code. I t\ o Materials: Q Round Bar::5A-36 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: Plate:54-36 O) lLl Nuts:54-563 GR A f a a Bergen Power Pipe Supports, Inc. J Producl Engineerlng Department z o E o Slide Bearings Exempt (NF-11 10) ]ONTROL REF a REV Certification =.RGEN-POWER PIPE SUPPORTS, ''V NO. 8460 Sheet REV. 1of 3 ,/d\ PAfI I N(,. 8460 ms H CERTIFIED DESIGN REPORT SUMMARY for Hd NUCLEAR POWER PLANT STANDARD SUPPORTS U.BOLT CRADLE GUIDE +DIRECTION OF LOADING Temperature:_.@9--T_ Note: rp The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: 7 7 DESIGN REPORT NO.: -t DS-8460 R0 DR-8460 R0 Rated Loads (lbs) for Classes 1,2,3 & MC REV PIPE SIZE Condition Level A Level B Level C Level D 500 500 500 500 1500 1500 2000 2000 2000 4000 4000 4000 5000 5000 500 750 750 750 750 1000 1000 1000 1000 3000 3000 3000 4000 4000 8000 8000 8000 10000 10000 2 21t2 3 4 5 6 I 10 12 14 16 18 20 24 r cenrry mrs oDRS OPERATING CONDITIONS FL Design 500 665 665 665 665 1500 1995 1500 1995 500 500 1500 1995 2250 2250 2250 2000 2660 2660 5320 5320 5320 6650 6650 3000 3000 6000 6000 6000 7500 7500 2000 4000 4000 4000 5000 5000 Test Condition (see Note) 665 665 665 665 1995 1995 1995 2660 2660 5320 5320 5320 6650 6650 "otpffiTil equirements of the applicable Code. I The Design Report & Design Specification Materials: N o o are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: Plate:5A-36 Round Bar::5A-36 Nuts:5A-563 GR A o, TU f, o a Bergen Power Pipe Supports, lnc. J Product Engineering Department 1 Itr Slide Bearings Exempt (NF-11 10) SONTROL REF o REV Certilication NO. 8460 PART NO. Sheet =.RGEN.POWEB PIPE SUPPORTS, ''V 2of3 ,/d\ 8460 tCERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS U.BOLT CRADLE GUIDE DIRECTION OF LOADING Temperature: 600 " F Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: S DS-8460 R0 DR-8460 R0 Rated Loads (lbs) lor Classes '|.,2,3 IE V PIPE SIZE Condition Level A Level B Level C 250 250 250 250 250 375 375 375 375 2500 333 333 333 333 665 665 1995 1330 1330 2660 2660 2660 3325 1500 1500 3000 3000 3000 3750 2500 3325 3750 2 2 1t2 3 4 500 500 500 1000 1000 2000 2000 2000 2500 2500 5 6 I 10 12 14 16 18 20 24 MC OPERATING CONDITIONS FL Design 250 250 250 500 500 1500 1000 1000 2000 2000 2000 750 750 2250 Level Test D Condition (see Note) 333 333 333 333 665 665 1995 1330 1330 2660 2660 2660 3325 500 500 500 500 1000 1000 3000 2000 2000 4000 4000 4000 5000 5000 3325 I certify this CDRS .otpli"t with the I 'equirements ol the applicable Code. I Materials: t\ o o Plate:5A-36 Round Bar::54-36 o, r.u f, a a The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: Nuts:3A-563 GR A Bergen Power Pipe Supports, Inc. J Product Engineering Department z g Slide Bearings Exempt (NF-11 10) tr CONTROL REF NO. 8460 PAHT NO. Sheet REV Certification :RGEN.POWER PIPE SUPPORTS, IN 3of3 i6'( 8460 U.BOLT CRADLE GUIDE rrArr -r I i* 116, !- - PIPE STZ;E 2 21t2 \s \lr, { REV 3 4 5 6 I 10 12 14 16 18 20 24 NOTES: F- o o 1 r--trltFil i A c D E 4 4 4 4 4 4 4 4 4 4 4 7 7 7 7 1t4 7 1t4 7 1t4 7 1t4 7 1t4 7 1t4 7 1t4 7 1t4 7 1t4 7 1t4 7 1t4 10 3t4 10 3t4 10 3t4 4 5 5 5 5 5 5 5 5 5 5 5 5 5 1t2 61t2 7 5t8 91/8 11 1t4 14 16 3t4 18 19 3t4 22 24 28 5112 5112 5 1t2 L 5 5 3/16 7t16 5 3t4 6114 6 13/16 5/16 5/16 7 I I 3/8 10 3/8 11 12 13 14 16 . All dimensions are in inches. 2. Dimensions are provided for user application onlv. F o) ORDERING INSTRUCTIONS: [U f CD a J z g E o Specify Part No.; CDRS Rev. No. & Size Designation. EXAMPLE: 9460-R/0- 6" (o G REV rFls Hd H BERGEN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART DATE 8460 91112007 m; H CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS UN]SLIDE CLAMP CRADLE SLIDE WITH BONDED SLIDE PLATE Hd DIRECTION OF LOADING Temperature: 350F NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: DS-8520 RO DR-8520 R0 Rated Loads (lbs) for Classes 1,2,3 & MC REV OPERATING CONDITIONS Design PIPE SIZE Condition 10000 10000 10000 10000 15000 15000 15000 15000 15000 20000 20000 20000 20000 20000 2 2 112 3 4 5 6 I 10 12 14 16 18 20 24 Level A 10000 10000 10000 10000 15000 15000 15000 15000 15000 20000 20000 20000 20000 20000 Level B 13300 13300 13300 13300 19950 19950 19950 19950 19950 26600 26600 26600 26600 26600 Test Condition Level C Level 15000 15000 15000 15000 20000 20000 20000 20000 30000 30000 30000 30000 30000 40000 40000 40000 40000 40000 22500 22500 22500 22500 22500 30000 30000 30000 30000 30000 (see Note) D 13300 13300 13300 13300 19950 19950 19950 19950 19950 26600 26600 26600 26600 26600 I certify this CDRS complies with the I 'equirements of the applicable Code. I Materials: r\ o o b uJ f @ a J Plate: 5A-36 EUGENE R. CLOUTIER Bolts: SA-307 GR B are in accordance with ASME Section lll, Subsection NF, 2007 Edition and are on file at: \uts:5A-563 GR A Studs:SA-36 Bergen Power Pipe Supports, lnc. Product Englneerin g Department z CI Exempt (NF-l110) Graphite Slide, Cotter Pins, o Washers, Retainers (r REV The Design Report & Design Specification Certification OONTROLREFNO. 8520 BERGEN-POWER PIPE SUPPORTS, INC. PABT NO. Sheet l-of 8520 1 ^\ UNISLIDE CLAMP CRADLE SLIDE WITH BONDED SLIDE PLATE WELD ilDil + ! a D E L 2" 4" 12" 5 3/8" 5" 5 3/16" 2 t/?" 4" 72" 6 t/?" 5r' 5 7 /16" 3rt 4" 12" 7" 5" 5 3/4" 4" 4" t?" 8 3/4" 5" 6 t/4" 5r' 4" t?" g7/9" 5" 6 3/4" 6" 4" t?" tl 3/4" 5" gt' 4" l?" 14" 5r' 10" 4" t2" 77 t/8" 5r' 7 5/t6" g 5/16" g 5/16" 12" 4" 12" 19 t/8', 5r' 70 3/9" 14" 4" t2" ?7 t/4', 5" 11" 16" 4" t?" 23 l/4" 5rt 12" 19" 7" 15" ?6" 5 t/?" 13" 20" 7" 15" 2g l/4" 5 7/?" 14" 24" 7" 15" 33 3/4', 5 1/?" t6" N O) l a a J z g (r o G -12 c lEV TIJ -] A \(t) o o "e" STZ:E PIPE \lo {ir ryPE NOTES: dimensions are in inches. 2. Dimensions are provided for user application onlv. 1 . All ORDERING INSTRUCTIONS: Specify Part No.; CDRS Rev. No. & Size Designation. EXAMPLE: 8520-R/0- 6" \o lEV TFA BERGEN-POWER PIPE SUPPORTS Hi H CDRS CATALOG INFORMATION SHEET PART DATE 8520 9t1t2007 m; H CERTIFIED DESIGN REPORT SUMMARY lor NUCLEAR POWER PLANT STANDARD SUPPORTS CLAMP CRADLE GUIDE Md DIRECTION OF LOADING Temperature-1Q@f NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. E) DESIGN SPEC NO.: 2 q DESIGN REPORT NO.: DS-8560 R0 DR-8560 RO Rated Loads (lbs) for Classes 1,2,3 & MC REV PIPE SIZE 2 2 112 3 4 5 6 I 10 12 14 16 18 20 24 OPERATING CONDITIONS FL Design Test Condition Gondition Level A Level B Level C Level D (see Note) 10000 10000 10000 10000 15000 15000 15000 15000 15000 20000 20000 20000 25000 25000 10000 10000 10000 10000 15000 15000 15000 15000 15000 20000 20000 20000 25000 25000 13300 13300 13300 13300 19950 19950 19950 19950 19950 26600 26600 26600 33250 33250 15000 15000 15000 15000 22500 20000 20000 20000 20000 30000 30000 30000 30000 30000 40000 40000 40000 50000 50000 13300 13300 13300 13300 19950 19950 19950 19950 19950 26600 26600 26600 33250 33250 22500 22500 22500 22500 30000 30000 30000 37500 37500 requirements of the applicable Code. I The Design Report & Design Specification Materials: Ir o o are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: Plate:5A-36 Round Bar::54-36 ct) Lu \uts:5A-563 GR A f C) Bergen Power Pipe Supports, lnc. a J Product Engineerlng DePartment z o E o Slide Bearings Exempt (NF-1 10) SONTROL REF EKF REV 1 Cerlilication BERGEN-POWER PIPE SUPPORTS, INC. Sheet NO. 8560 REV. PART NO. 8560 l_of 3 ^\ nfr H CERTIFIED DESIGN REPORT SUMM ARY for Hf, NUCLEAR POWER PLANT STANDARD SUPPORTS CLAMP CRADLE GUIDE DIRECTION OF LOADING Temperature: 600 NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: 4 'F DESIGN REPORT NO.: DS-8560 R0 DR-8560 RO Rated Loads (lbs) for Classes 1,2,3 & MC REV OPERATING CONDITIONS FL Design Condition Level A Level B Level C Level D Test Condition (see Note) 500 750 500 665 665 665 665 1500 1995 1500 1995 1995 2660 2660 5320 5320 2250 2250 2250 16 500 500 500 500 1500 1500 2000 2000 2000 4000 4000 3000 3000 6000 6000 1000 1000 1000 1000 3000 3000 3000 4000 4000 8000 8000 665 665 665 665 1995 1995 1995 2660 2660 5320 5320 18 20 24 4000 5000 5000 5320 6650 6650 6000 7500 7500 8000 10000 10000 5320 6650 6650 PIPE SIZE 2 2 1t2 3 4 5 6 I 10 12 14 500 500 1500 2000 2000 4000 4000 4000 5000 5000 750 750 750 equirements of the applicable Code. I Materials: to o Plate:5A-36 o, Round Bar::54-36 IU Nuts:5A-563 GR A l a Bergen Power Pipe Supports, lnc. 9. J Producl Engineering Department z g (r o REV The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: Slide Bearings Exempt (NF-1 1 10) CONTROL REF Certitication BERGEN.POWER PIPE SUPPORTS, INC. Sheet 2ot 3 NO. 8560 K PART NO. 8560 CERTIFIED DESIGN REPORT SUMMARY r7l; U for NUCLEAR POWER PLANT STANDARD SUPPORTS CLAMP CRADLE GUIDE Hd DIRECTION OF LOADING Temperature: 600 Note: 'F The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: DS-8560 R0 DR-8560 RO Rated Loads REV PIPE SIZE for Classes 1,2,3 & MC OPERATING CONDITIONS FL Design Gondition Level A Level B Level C 2 250 250 2 1t2 250 3 250 250 375 375 375 4 250 250 5 6 500 500 500 1000 1000 2000 2000 2000 2500 2500 500 2500 333 333 333 333 665 665 1995 1330 1330 2660 2660 2660 3325 2500 3325 I 10 12 14 16 18 20 24 250 500 1500 1000 1000 2000 2000 2000 375 750 750 2250 1500 1500 3000 3000 3000 3750 3750 Level Test Gondition (see Note) D 333 333 333 333 665 665 1995 1330 1330 2660 2660 2660 3325 3325 500 500 500 500 1000 1000 3000 2000 2000 4000 4000 4000 5000 5000 rcenrry mrs uuFrD equirements of the applicable Code. I "otp@ Materials: t\ Q F Plate:54-36 b Round Bar::54-36 \uts:5A-563 GR A o lU l a a Bergen Power Pipe Supports, lnc. - Product Engineering Department z o Slide Bearings Exempt (NF-11 10) E sONTROL REF IO 7 (\ REV The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: Certification BERGEN.POWER PIPE SUPPORTS, INC. Sheet lof 3 NO. 8560 K PAt{ r N(,. 8560 CLAMP CRADLE GUIDE 6 PIPE 5,TZE A c D E 2 4 4 4 4 4 4 4 4 4 4 4 7 7 7 7 1t4 7 1t4 71t4 7 1t4 7 114 7 1t4 7 1t4 7 1t4 7 1t4 7 1t4 7 1t4 10 3t4 10 3t4 5 1t2 1t4 11 1t2 13 1t2 14 19 1t4 23 25 27 5 5 5 5 5 5 5 5 5 5 5 5 112 10 3t4 31 1t2 51t2 2 1t2 3 4 5 6 8 10 12 14 16 18 20 24 lEV NOTES: l- o o o) 1 6 7 1t4 8 114 I 21 L 5 5 3t16 7t16 5 314 6114 6 13/16 7 8 5/16 5/16 9 3/8 10 3/8 11 5112 12 13 14 16 . All dimensions are in inches. 2. Dimensions are provided for user application onlv. ORDERING INSTRUCTIONS : tU l U) a J z (, E Specify Part No.; CDRS Rev. No. & Size Designation. EXAMPLE: 8560-R/0- 6" o G (o 1EV m E BERGEN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART 8560 DATE 91112007 m; CER\IFIED DES\GN REPORT SUtltiltARY lor NUCLEAR POWER PLANT STANDARD SUPPORTS GRAPHITE SLIDE PLATE WELDED TYPE Nd fl DIRECTION OF LOADING Temperature:ff NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DS-8820 R0 DR-8820 RO Rated Loads (lbs) lor Classes 1,2,3 & MC DESIGN SPEC NO.: 6 4 DESIGN REPORT NO.: REV stzE 1 2 3 4 5 6 7 8 I 10 11 12 13 14 15 16 17 18 OPERATING CONDITIONS Design Condition Level A 40000 56000 40000 56000 88000 1 36000 1 84000 88000 136000 84000 232000 280000 328000 376000 472000 568000 1 26000 1 1 232000 280000 328000 376000 472000 568000 1 26000 1 53000 1 80000 53000 80000 207000 243000 207000 243000 261 000 261 000 324000 324000 1 -" equirements of the applicable Code. Level C Level D (see Note) 53200 60000 84000 80000 2000 1 76000 53200 11 74480 117040 627760 755440 1 67580 203490 239400 229500 270000 275310 31 3231 90 364500 391 500 486000 80880 308560 372400 436240 500080 347130 430920 1 89000 0500 272000 368000 464000 560000 656000 752000 944000 1 1 36000 252000 306000 360000 1 80880 244720 308560 372400 436240 500080 627760 755440 1 67580 203490 239400 4000 275310 486000 522000 648000 3231 90 347',130 41 430920 The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Slide Bearino: Graphite Bergen Power Pipe Supports, lnc. J Product Englneering DePartment o = tr Slide Bearinq Exempt (NF-1 o REV 74480 117040 I Plate: 5A-36 o b IU l o a 132000 204000 276000 348000 420000 492000 564000 708000 852000 1 244720 Materials: r\ o Test Condition Level B Certification 1 10) CONTROL REF BERGEN.POWER PIPE SUPPORTS, INC. Sheet lof 1 NO. A 8820 PART NO. 8820 GRAPHITE SLIDE PLATE WELDED TYPE l/2" f, t t/2" >< l ilFil ! t/ 2" Tr4" ffi l il T I uc' 3/8" t6"5" 7" 8" 4 19" 9 36" 42" 48" 6 6 IEV 35" 41" 47" 59" 71" t2 t4" 15" 5 t/2" 4" 4" 4" 4 7/2" 13 t6 t7 f.r o o o, NOTES: ?8" 30" 27" 29" 5 5 5 5 5 t/2" 7/?" l/2" t/2" t/2" 4 t/?" 4 t/2" 4 t/2" 4 t/2" 4 t/?" 1. All dimensions are in inches. 2. Dimensions are provided for user application onlv. lrJ f U) U) ORDERING INSTRUCTIONS: J z g E o G Specify Part No.; CDRS Rev. No. & Size Designation. EXAMPLE: 8820-R/0- 6" REV r77n Hd fl BERGEN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART DATE 8820 91112007 m CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS Pre-lnsulated Ptpe Slide H ) O \r' Et- DIRECTION OF LOADING Temperature: 650 o F is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. Note: The temperature shown above DESIGN SPEC e NO.: NO.: DESIGN REPORT REV PIPE SIZE Design Condition 314" 1" OPERATING CONDITIONS 2" 810 3tt 1140 1810 810 1 140 1810 2260 2750 2260 2750 C\I AI o t o REV 798 900 931 1050 1077 1516 2407 3006 3658 1215 1710 2715 3390 4125 798 931 1077 1516 2407 2280 3620 3006 3658 4520 5500 *tp, Code. I Materials: E 505 652 700 Plate: z 760 980 1200 1400 1620 11t2" (o J 735 1114" o a 570 652 490 600 700 @ U) 505 380 490 600 cenrry tnrs CDRS equirements of the applicable :) (see Note) 380 6rt IU Level D Level B 5rt Test Condition Level C Level A 4" r DS.8821 RO DR.8821 RO Rated Loads (lbs) for Classes ,2,3 & MC ffi Certification Bolts: lnsulation Nuts: Studs: Outer Clamp 5A-36 SA-307 GR B HD Calcium Silicate 54-563 GR A The Design Report & Design Specification are in accordance with ASME BPVC Section lll Subsection NF, 2007 Edition and are on file at Bergen Power PiPe SuPPorts,lnc. Product Engineering DePartment 54-36 54-36 Slide Plates Exempt (NF-1 1 10) CONTROL REF BERGEN.POWER PIPE SUPPORTS, INC. Sheet l of 1 NO. A REV. 8821 PART NO. 8821 Pre-lnsulated Pipe Slide i/i t/i, (: ,,. :/,rz I ,r' ') ['-r" -] l i I -f \lr) \(r) lEV PIPE SIZE B c 4" 1 112" 4" 2" 2" 1 1t4" 4" 2" 1 1t2" 4" 2" 4" 21t2" 21t2" 4t' 21t2 4" 3" 3" 4" 4" 4tt 4" 4112" 5" 4" 5112" 6" 314" 1rt @ E 4 7 t16" 4 11/16" 5 1/1 6" 5114'' 57t8" 6 3/8" 6 13/1 6" I 3/16" 9 1/16 9 15/16" 3'' THK INSUL. 2'' THK INSUL. 1'' THK INSUL. L c B 6" 4tt 6" 4" 6" 4" 6" 4" clrr 4" g" 4" cltr 4" 12" 4" 12" 4" 12" 4" E L 2112" 6 1/8" 3rt 6 5/16" 6" 6" B c E N/A 611/16" 6rt 6 3t4" 6" 7 3t8" g" 6tt 5 112" I 1/1 6" 4 1t2" 7 15116" g" 6" 5112" 9 9/16" 4 112" 8 7 t16" clrr 6tt 5 1t2', 10 3/16" 6" 11 1t2" 5rt 9 13/16" 12" 6tt g" 12318" 6tt 12" 1 1/16 5" 0 g" 13114" 7 112" 1 1 9/16" 12" 6" 3" 4" 4" L g, gt' g" 12" 12" 12" 1. All dimensions are in inches. NOTES: o 2. @ Dimensions are provided for user application only. ol (\I uJ l U) I J ORDERING INSTRUCTIONS: Specify Part No.; CDRS Rev. No. & Size Designation and lnsulation Thickness. z o E o sr EXAMPLE: 8821-3"X2"-R/0 (o ]EV ffi U BERGEN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART 8821 DATE 2t26t2008 CERTIFIED DESIGN REPORT SUMMARY TFli- for NUCLEAR POWER PLANT STANDARD SUPPORTS Pre-lnsulated Pipe Slide Hd H lFd v,,/; 'lrJ;2 i/ii iil2 DIRECTION OF LOADING Temperature:.Qflf NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: ra DS-8821 R0 DR-8821 R0 Rated Loads (lbs) for Glasses 1,2,3 & MC REV Design PIPE SIZE Condition Fd OPERATING CONDITIONS Level A 3rt 1 4" 1810 380 490 600 700 810 1140 1810 c 2260 2750 2260 2750 380 490 600 700 810 314" 1tt 1114" 1112" 2" 6" 140 Test Gondition Level C Level D (see Note) 505 570 652 735 798 900 1050 760 980 1200 1400 1620 505 652 798 Level B 931 1077 1516 2407 3006 3658 1215 1710 2715 3390 4125 2280 3620 4520 5500 931 1077 1516 2407 3006 3658 fd+fl NOTE: For simultaneous loading Fd allowable Fl allowable I certify this CDRS complies with the I requirements ol the applicable Code. I @ Materials: (o Plate: o C! Bolts: lnsulation Nuts: Studs: N o tIJ f a L J z g Cuter tr SA-36 SA-307 GR B HD Calcium Silicate 5A-563 GR A 5A-36 5A-36 Slide Plates Exempt (NF-1 1 10) o REV Clamp The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, lnc. Product Engineerlng DePartment CONTROL REF BERGEN.POWER PIPE SUPPORTS, INC. Certification Sheet 1of 3 NO. 8822 PART NO. /N 8822 rn; H CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS Pre-lnsulated Pipe Slide H* -FU DIRECTION OF LOADING Temperature: 650 " F NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: DS-8821 R0 DR-8821 R0 Rated Loads (lbs) for Classes 1,2,3 & MC REV uesrgn PIPE SIZE OPERATING CONDITIONS Gondition Fu Level A Level B Level G Level D 380 490 600 700 810 1 140 1810 380 490 600 700 810 1 140 1810 505 570 735 760 980 1200 1400 1620 2260 2750 2260 2750 3t4 1rt 11t4" 11t2" 2" 3rt 4" 5rt 6rt 652 900 1050 798 931 1077 1516 2407 3006 3658 1215 1710 2715 3390 4125 2280 3620 4520 5500 Test Gondition (see Note) 505 652 798 931 1077 1516 2407 3006 3658 fu+fl NOTE: For simultaneous loading Fu allowable Fl allowable lcertity this CDRS .otpti". with the I requirements ol the applicable Code. I The Design Report & Design Specification Materials: @ O b ot N o Plate: SA-36 SA-307 GR B HD Calcium Silicate SA-563 GR A z Bolts: lnsulation Nuts: Studs: o Slide Plates Exempt (NF-1 1 10) lll f a a J It REV Outer Certification Clamp 5A-36 5A-36 are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe Supports, Inc. Product Englneerlng Departmenl CONTROLREFNO. BERGEN.POWER PIPE SUPPONTS, INC. Sheet 2ol3 A 8822 PART NO, 8822 m; H CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS Pre-lnsulated Pipe Slide Hd Fl #-----) Fl v'r't'< z'i ,, /4 /l tr4 i/t /i2 DIRECTION OF LOADING Temperature:.lQ!0 'f NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: 7 { DESIGN REPORT NO.: DS-8821 R0 DR-8821 R0 Rated Loads (lbs) for Classes 1,2,3 & MC F lE' 7 ueslgn PIPE SIZE 3t4" 1" 1114" 1112" 2" 3" 4" 5rt 6" OPERATING CONDITIONS Condition Fl Level A Level B Level G 380 490 600 700 810 1 140 1810 380 490 600 700 810 1 140 1810 505 570 735 2260 2750 2260 2750 652 798 931 1077 1516 2407 3006 3658 900 1050 1215 Test Condition Level D 760 980 1200 1400 1620 1710 2280 2715 3620 4520 5500 3390 4125 (see Note) 505 652 798 931 1077 1516 2407 3006 3658 I certify this CDRS compties wnn tne I 'equirements of the applicable Code. I @ Materials: (o Plate: o E C\I o IU f, U) I J z (5 (r o REV Bolts: lnsulation Nuts: Studs: Clamp sA-36 SA-307 GR B HD Calcium Silicate 5A-563 GR A 5A-36 5A-36 Cuter Slide Plates Exempt (NF-1110) The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Bergen Power Pipe SupPorts, lnc. Product Engineerlng DePartment CONTROLREFNO. BERGEN-POWER PIPE SUPPORTS, INC. She€t 3_of 3 8822 PART NO. /N 8822 nsulated Pipe Guide g r>' TT t7 1'' THK INSUL. T -fr -J L- 2'' THK INSUL. 411116" 6 11/16" 10 1 1/1 6" 13114" NOTES: dimensions are in inches. are provided for user application only. penetration weld specify optional beveled ends. 3. For full 1 . All 2. Dimensions @ o (o c\I c! uJ :) U) I J z g (r OR DERING INSTRUCTIONS: Specify Part No.; CDRS Rev. No. & Size Designation, lnsulation Thickness and Beveled Ends if required. o EXAMPLE: 8822-3"X2"-R/0 BERGEN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART 8822 DATE 2t26t2008 nsulated Pipe Guide fi"cun. \ A T- A +l/16"AHOLES BY CUsT. 1t' MAX. NOTES: 1 . All dimensions are in inches. 2. Dimensions are provided for user application only. @ o (o N c\l I.U l U) I J z ORDERING INSTRUCTIONS: Specify Part No.; CDRS Rev. No. & Size Designation, lnsulation Thickness. g IL o EXAMPLE: 8823-3"X2"-R/0 BERGEN.POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART 8823 DATE 2t2612008 ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) CERTIFIED DESIGN REPORT SUMMARY TT7; g for NUCLEAR POWER PLANT STANDARD SUPPORTS GRAPHITE SLIDE PLATE BOLTED TYPE Hd DIRECTION OF LOADING Temperature:ff NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition' 7 K REV DS-8840 R0 DR-8840 R0 Rated Loads (lbs) for classes 1,2,3 & Mc DESIGN SPEC NO.: DESIGN REPORT NO.: SIZE 1 2 3 4 5 6 7 I 9 10 11 12 13 14 15 16 17 18 OPERATING CONDITIONS Design Condition Level A Level B Level C 48000 48000 64000 96000 1 20000 144000 1 92000 240000 288000 63840 72000 851 20 96000 144000 1 80000 21 6000 64000 96000 20000 1 44000 1 1 92000 240000 288000 336000 432000 528000 1 35000 1 62000 89000 21 6000 1 234000 270000 288000 -" 'equirements of the applicable 127680 59600 1 91 520 1 63840 851 20 202500 270000 215460 251370 287280 311220 243000 283500 324000 351 000 324000 378000 432000 468000 270000 3591 00 288000 383040 405000 432000 540000 576000 528000 1 35000 1 62000 1 89000 21 6000 234000 1 127680 240000 288000 384000 480000 79550 336000 432000 1 1 255360 31 9200 383040 446880 574560 702240 1 79550 215460 251370 287280 311220 576000 672000 864000 1 59600 91 520 056000 3591 00 383040 Code. I The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at Slide Bearino: Graphite o, 96000 28000 1 92000 1 383040 446880 574560 702240 9200 Plate:34-36 o (see Note) 288000 360000 432000 504000 648000 792000 255360 31 Materials: to Test Condition Level D ul f U) L Bergen Power Pipe Supports, lnc. J Product Englneering Deparlment z o tr o REV Slide Bearino Exempt (NF-1 Certification 1 10) 3ONTROLREFNO. BERGEN.POWER PIPE SUPPOBTS, INC. Sheet l_of 1 A REV. 8840 PAHI N(,. 8840 GRAPHITE SLIDE PLATE WELDED TYPE ,'H" HOLE !- 3" -l ryP. n ilF.. A.. l/4" __ ilBil 3/9" l---- \ro \(f) lEV o o F o, 16" 5" 5" 5" 19' 21" 5rt 4" 1" t3/t6" ?4" 5" 4" 1" t3/16" 6" 10" ?l g" 12" 3, tzu 4 15" i 18" i 22" 4" 4" 4" 6 24" 28" 30" 5" 4u 1r' t3/16" 7 30" 34" 36" 5" 4" 1" 73/t6', 8 36" 40" 4?" 5" 4" 1" 9 42" 46" 49" 5" 4" 1" t3/t6" t3/t6" 10 54" 59" 60" , 5" 4" 1tt 13/16" n 66" 70" 72" 5rt 4" lrt 13/16" t2 15" 5 l/2" 4 t/2" 19" 5 l/2" 4 t/2" t/4' t/4' t4 21" 5 t/?u 4 t/2" 1/4" t5/16" t5 24" 27 5 l/2" 4 t/z', t6 26u 32" 5 l/z', 4 7/2" l/4" l/4" t7 30" l/2" 29 t/?" 33 l/2" t t t t t 15/t6" 13 tg l/2" 2t l/2" ?4 t/z', 36" 5 t/?' 4 t/zu 7 t/4', t t/8' t t/9" I t/9" 32', 35t/2" 38" 5 t/?' 4 l/2" tl/4" 18 f- rrErr t?" t4" 1g" t 5 I NOTES: " 2t" 24" ?7" 30" : " "i t5/16" " tt/8" 1 . All dimensions are in inches. 2. Dimensions are provided for user application onlv. r.rJ f U) I ORDERING INSTRUCTIONS: J z g E o G G lEV TFTN v- U Specify Part No.; CDRS Rev. No. & Size Designation. EXAMPLE: 8840-R/0- 6" BERGEN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART DATE 8840 9/1 12007 CERTIFIED DESIGN REPORT SUMMARY {FA E for bd NUCLEAR POWER PLANT STANDARD SUPPORTS GUIDE BASE WELDED TYPE DIRECTION OF LOADING Temperature: 600" F NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: DS-8860 R0 DR-8860 R0 lor Classes 1,2,3 & MC Rated Loads F lE' PIPE SIZE OPERATING CONDITIONS FV Design Test Condition Condition Level A Level B Level C Level D (see Note) 10000 10000 10000 10000 15000 15000 15000 15000 15000 20000 20000 20000 25000 25000 10000 10000 10000 10000 15000 15000 15000 15000 15000 20000 20000 20000 25000 25000 13300 13300 13300 13300 19950 19950 19950 19950 19950 26600 26600 26600 33250 33250 15000 15000 15000 15000 20000 20000 20000 20000 30000 30000 30000 30000 30000 40000 40000 40000 50000 50000 13300 13300 13300 13300 19950 19950 19950 19950 19950 26600 26600 26600 33250 33250 2 2 112 3 4 5 6 8 10 12 14 16 18 20 24 22500 22500 22500 22500 22500 30000 30000 30000 37500 37500 I certify this CDRS complies with the requirements of the applicable Code. Materials: N o o Plate:3A-36 b tU f Slide Bearinos: Graphite @ U) Bergen Power Pipe Supports, lnc. J Product Engineerlng DePartment z o tr o REV The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: Slide Bearings Exempt (NF-11 10) CONTROLREFNO. 8860 Certification BERGEN.POWER PIPE SUPPOBTS, INC. Sheet lof 3 n\ PART NO. 8860 CERTIFIED DESIGN REPORT SUMMARY rflfH for NUCLEAR POWER PLANT STANDARD SUPPORTS GUIDE BASE WELDED TYPE Hd DIRECTION OF LOADING Temperature: 600 NOte: 'F The temperature shown above is for Design and Operating Conditions. For the Test Gondition (Hydro) 100f. For higher temperatures in the Test Condition use Level B loads the maximum temperature is up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: 7 s DESIGN REPORT NO.: DS-8860 R0 DR-8860 R0 Rated Loads (lbs) lor Classes 1,2,3 & MC REV PIPE SIZE FL Design Gondition Level A 500 14 16 500 500 500 500 1500 1500 2000 2000 2000 4000 4000 18 20 24 4000 5000 5000 2 2 1t2 3 4 5 6 I 10 12 500 500 500 1500 1500 1500 2000 2000 4000 4000 4000 5000 5000 OPERATING CONDITIONS Level C Level B 665 665 665 665 1995 1995 1995 2660 2660 5320 5320 5320 6650 6650 750 750 750 750 2250 2250 2250 Test Condition Level (see Note) D 3000 3000 6000 6000 1000 1000 1000 1000 3000 3000 3000 4000 4000 8000 8000 665 665 665 665 1995 1995 1995 2660 2660 5320 5320 6000 7500 7500 8000 10000 10000 5320 6650 6650 rcenrry Inrs uuhD equirements of the applicable Code. I "o.o@ Materials: to )late:5A-36 o Slide Bearinqs: Graphite o) The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: Llt f o a Bergen Power Pipe Supports, lnc. J Product Engineering Department z Itr Slide Bearings Exempt (NF-11 10) ]ONTROL REF o REV Certilication BERGEN.POWER PIPE SUPPORTS, INC. NO. 8860 PART NO. Sheet 8860 Zot 3 ^\ IM H CERTIFIED DESIGN REPORT SUMMARY for NUCLEAR POWER PLANT STANDARD SUPPORTS GUIDE BASE WELDED TYPE Hd DIRECTION OF LOADING Temperature: 600 " F Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro) the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads up to the temperature shown for the Operating Condition. DESIGN SPEC NO.: DESIGN REPORT NO.: DS-8860 R0 DR-8860 R0 Rated Loads (lbs) lor Glasses 1,2,3 & MC REV PIPE SIZE OPERATING CONDITIONS FL Design Condition Level A Level B Level C Level D 250 250 250 250 250 375 375 375 375 500 500 500 1000 1000 2000 2000 2000 2500 2500 500 2500 333 333 333 333 665 665 1995 1330 1330 2660 2660 2660 3325 2500 3325 500 500 500 500 1000 1000 3000 2000 2000 4000 4000 4000 5000 5000 2 21t2 3 4 5 6 I 10 12 14 16 18 20 24 250 250 250 500 1500 1000 1000 2000 2000 2000 750 750 2250 1500 1500 3000 3000 3000 3750 3750 Test Condition (see Note) 333 333 333 333 665 665 1995 1330 1330 2660 2660 2660 3325 3325 lcertity this CDRS compnes witn tne I requirements of the applicable Code. I Materials: to rlate:5A-36 o 3lide Bearinos: Graohite O) lrJ f, a Bergen Power Pipe Supports, Inc. L J Product Englneerlng DePartment I(r Slide Bearings Exempt (NF-11 10) = 3ONTROLREFNO. 8860 o REV The Design Report & Design Specification are in accordance with ASME BPVC Section lll, Subsection NF, 2007 Edition and are on file at: Certilication BERGEN.POWER PIPE SUPPORTS, INC. Sheet lof 3 A REV. PART NO. 8860 'f' GUIDE BASE WELDED TYPE r/4" 7/ /8 l//2 ,, ,, TYP. PIPE STZE 2" -16" Ct -?o" 24" 19" 6 lEV NOTES: F- o o F 1 A c 4" 7" 7" 7 r/4" ]F 10 3 /4" n r/4" 5" 4" 4" 4" . All dimensions are in inches. 2. Dimensions are Drovided for user application onlv. 3. For use with 8460 & 8560. o) I.JJ f U) U) J z g (E o G ORDERING INSTRUCTIONS: Specify Part No.; CDRS Rev. No. & Size Designation EXAMPLE: 8860-R/0- 6" REV ffi fl BERGEN-POWER PIPE SUPPORTS CDRS CATALOG INFORMATION SHEET PART DATE 8860 9t112007 ( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ) EXECUTIVE OFFICES MASSACHUSETTS 225 Merrimac Street Woburn, MA 01801 Tel: 781.935.9550 Fax: 781.938.0026 e-mail: [email protected] MANUFACTURING PLANT PENNSYLVANIA 484 Galiffa Drive Donora Industrial Park Donora, PA 15033 Tel: 724.379.5212 Fax: 724.379.9363