42BJ ICM - Sizes 1.3 - 2.3 - 4.4 Individual Comfort - AHI
Transcription
42BJ ICM - Sizes 1.3 - 2.3 - 4.4 Individual Comfort - AHI
42BJ ICM - Sizes 1.3 - 2.3 - 4.4 Individual Comfort Module for variable air flow systems Fresh air inlet Hot/chilled water inlet/outlet Thermophonic ducting Supply/return ModuBoot ICM Selection manual The photo shown on the front cover is solely for information, and not contractually binding. The manufacturer reserves the right to make changes without previous notification. Contents 1 - INTRODUCTION..............................................................4 1.1 - Comfort ............................................................................4 1.2 - Air quality .........................................................................4 1.3 - Carrier QUALITY PLUS..................................................5 8 - CARRIER NUMERIC CONTROLLER.......................22 9 - TECHNICAL SPECIFICATIONS.................................23 9.1 - Valves ..............................................................................23 9.2 - Flexible water pipes ........................................................24 2 - FEATURES.........................................................................5 2.1 - Physical and electrical data...............................................6 2.2 - Dimensional drawings.......................................................7 10 - ACCESSORIES ..............................................................24 10.1 - Electromechanical controller accessories .....................24 10.2 - Carrier numeric controller accessories .........................25 3 - SAFETY CONSIDERATIONS.......................................11 3.1 - General ............................................................................11 3.2 - Precautions against electrocution....................................11 3.3 - Installation Recommendations........................................11 3.4 - Conformity......................................................................11 11 - PERFORMANCE DATA...............................................26 11.1 - Cooling capacities - cold water coil .............................26 11.2 - Heating capacities - hot water coil ...............................29 11.3 - Coil pressure drop.........................................................34 11.4 - Valve pressure drop.......................................................36 11.5 - Electric heater performance..........................................37 11.6 - Sound power level.........................................................39 11.7 - Electrical data ...............................................................41 11.8 - Air flow/static pressure available characteristics ..........43 11.9 - Pressure diaphragm characteristics...............................46 4 - APPLICATION ................................................................12 4.1 - Multi-zone buildings with varying load .........................12 4.2 - Cooling............................................................................12 4.3 - Heating ............................................................................13 4.4 - Air distribution................................................................13 5 - SYSTEM DESCRIPTION ..............................................13 5.1 - Air conditioning system ..................................................13 5.2 - Water chiller ....................................................................13 5.3 - Fresh air handling unit ....................................................13 6 - MAIN COMPONENTS OF THE ICM .........................14 6.1 - Fresh air controller..........................................................14 6.2 - Filter and access..............................................................14 6.3 - Water coil ........................................................................15 6.4 - Condensate pan ...............................................................15 6.5 - PTC electric heater .........................................................15 6.6 - Flow measurement device...............................................15 7 - CARRIER ELECTROMECHANICAL CONTROLLER WITH FAN SPEED CONTROLLER ...............................................................16 7.1 - Description ......................................................................16 7.2 - Speed controller ..............................................................17 7.3 - General characteristics ....................................................17 7.4 - Available ICM configurations.........................................18 7.5 - Technical specifications for the heating/cooling changeover switch ...........................................................21 7.6 - Room thermostats ...........................................................21 12 - ICM CODIFICATION ..................................................48 13 - SPECIFICATION GUIDE ............................................51 1 - INTRODUCTION The Carrier 42BJ ICM is a compact fan coil designed specifically to air condition individual rooms ranging in area between 25 and 50 m2. There are three sizes and three possible motor drive selections. The main components of the unit are a centrifugal fan, a fresh air inlet with adjustable air quantity, a throw-away filter, a chilled water cooling coil and a hot water heating coil and/or an electric resistance heater. Flexible, thermally and acoustically insulated ducts connect ICM units to one or more plenums in the ceiling void which feed unobtrusive linear ceiling diffusers (typically Carrier Moduboot 35BD/35SR units) supplying the individual rooms or zones. The total air conditioning system comprises one or more Carrier air- or water-cooled chillers and one air handler which supplies fresh air to the Carrier 42BJ ICMs. The ICMs may be installed above false ceilings or floor voids but away from occupied zones, ideally in centre areas where they are easily connected to hot water and chilled water circuits as well as to the fresh air supply. These circuits, normally installed in the corridors and halls, never pass through the conditioned spaces. Only the passive elements of the system, the 35BD/35SR diffusers and their relatively short connecting ducts, are within the space which they serve. Noise levels, or precisely the absence of noise, are a critical criterion in determining the design of an air conditioning system and its components. Low inherent noise was a key factor in the design of the ICM. This and its high available static pressure, enabling it to be installed well away from especially noise-sensitive areas, expand its field of application to embrace study rooms, consultation rooms and like areas where ambient noise is itself naturally very low. Low noise and remoteness from the space which it serves, permitting easy servicing, are key attributes influencing the selection of an air conditioning system. Supply/return ModuBoot Hot/chilled water inlet/outlet Further, with these models, connection to a building energy management system (BMS) allows all units to be controlled centrally to satisfy overriding criteria or to respond to local selections. The central energy management system controls, continuously, the comfort level in each zone and gives instant reaction to system inputs to achieve optimum energy usage without disturbing individual comfort level selections. 1.2 - Air quality 1.2.1 - Fresh air All ICMs models have a fresh air inlet with an air volume regulator for precise control of the fresh air admitted, in accordance with local health codes. The level of fresh air introduced can be set exactly to take account of the room occupancy. In spaces which must be air conditioned, such as totally enclosed or windowless rooms, or rooms with high heat gains, the controllable fresh air supply of the ICM will make an important contribution towards achieving the required air quality. 1.2.2 - Air filtration The cleanliness of the supply air is one of the primary functions of air treatment giving the most basic and important measure of ‘air quality’ essential to our health. The air which we breathe contains a wide diversity of particles, pollens and dusts, all possible allergens, which have varying effects upon the health of individuals. They come from many sources both within and outside the building. Air filtration protects people against the health hazards of these pollutants, and protects furnishings and equipment against contamination and damage which they can cause. ICM fan coils have high efficiency (F5 type) return air filters or optional F6 type filters, according to applicable standards. Indoor Air Quality (IAQ) In the last ten years Carrier has been committed to developing an Indoor Air Quality (IAQ) control system that is integrated into the air conditioning units. This is a major innovation, and the beginning of a new era in air conditioning. It means that each individual comfort module (ICM) is equipped with a high-tech fresh air intake and filtration control system to effectively combat any type of pollutant. This guarantees optimised indoor air quality in three stages, as described below: 1 - High-efficiency filtration with filter type F6 2 - Air purification: Purification or elimination of contaminants is achieved by degradation of the gases present and deactivation of potentially irritating airborne substances. 1.1 - Comfort The top of the range ICM can have a Carrier Maestro Zone controller with each room occupant having his or her own Zone User Interface, on a wall or desk, with which to select the preferred comfort level: • Room ambient temperature • Lighting on or off • Venetian blinds raised or lowered and their inclination • Control ventilation air • Select Occupied or Unoccupied mode at each ICM to control energy usage. 4 3 - Modulation of the fresh air flow. In order to control the air flow supplied to a room, Carrier air conditioners can be equipped with a fresh air flow modulation system. Three objectives: To adjust the ventilation rate to the actual occupation in the rooms - To maintain good indoor air quality in order to ensure comfort and hygiene for the occupants. - To control energy consumption due to the air renewal in the rooms and adjust it to avoid “overventilation” of the building, and to minimise the operating costs especially during unoccupied periods. Operating pinciples The occupants of a room release on average 0.0045 l/s (16,2 l/h) CO2 A CO2 sensor, placed in the return air duct of the terminal, checks the concentration in the air conditioned room. The measured concentration indicates the actual occupation of the room. The sensor sends a signal to the numerical Carrier controller which in turn passes an action signal to the fresh air valve: if the CO2 concentration is below a threshold value: the fresh air flow is minimal or zero, - if it is above: the fresh air flow is increased up to the specified maximum. For more information on the Air4Life system, used in the 42BJ ICM, contact your local Carrier office. 1.2.3 - Operating environment The 42BJ has been designed for internal application in “urban” conditions having a non-corrosive, dust free and non-marine environment. The concentrations of the following chemicals must not be exceeded in any event: • SO2 • H2S • NO, NO2 • NH3 • N2O < 0,02 ppm < 0.02 ppm < 1 ppm < 6 ppm < 0.25 ppm 1.3 - Carrier QUALITY PLUS The Carrier Quality Plus philosophy embraces the product itself, its conception, its design and the integrity of its declared performance (proven in rigourous laboratory tests) as well as the manufacturing processes, materials and components used to create the product. Carrier has carried LRQA quality certification to ISO 9001 since 1989. 2 - FEATURES The modular design of the ICM allows the fan coil to be used efficiently, singly or in multiples, to heat or cool small to medium spaces. With an overall depth of only 270 mm (except size 4, depth: 345 mm), they are easily installed in the voids above suspended ceilings or below false floors. Their casings are built of 10/10 galvanized sheet steel with a lining of 13 mm fibre wool matting which in turn is protected by a layer of erosion-resisting neoprene. The fan motor access door is coated with 13 mm of fibre wool blanket. The air filter access panel is covered with 5 mm of foam. NOTE: Operating limits: Supply air temperature 12°C, when the unit is installed where ambient temperature is 27°C dry bulb and 70% relative humidity. NOTE: To arrive at the total supply air flow, add the fresh air flow to the air flow read from the diagram. 5 2 - FEATURES (CONTINUED) 2.1 - Physical and electrical data 42BJ ICM Size 1.3 Size 2.3 Nominal air flow l/s (m3/h) 144 (520) 189 (680) Size 4.4 264 (950) Total cooling capacity - cold water coil* kW 2.88 4.44 6.01 Heating capacity - hot water coil** kW 1.68 2.50 3.79 Power supply 230 V - 1 ph - 50 Hz U% ± 10 ± 10 ± 10 Operating weight (6 row coil and control) kg 31 40 60 Water coil With 3/8 in copper tubes, aluminium fins at 1.6 mm spacing, purge valve and 1/2 in. screw connection: • Test pressure • Operating pressure kPa kPa 2400 1600 2400 1600 2400 1600 5-row coil: • Number of passes • Water content l 2 0.90 3 1.20 3 1.50 5 1 5 1 5 1 2 1 3 1 3 1 l l 0.90 0.20 1.20 0.29 1.50 0.45 kW A 1.70 11 1.90 11 1.76 11 W 80 80 80 l/s (m3/h) Pa single inlet 144 (520) 145 double inlet 189 (680) 120 double inlet 264 (950) 85 W V A A 175 80 0.77 3.04 240 80 1.04 4.44 181 80 0.81 3.36 240 x 400 240 x 550 315 x 550 30 35 40 mm l/s (m3/h) l/s (m3/h) 125 8.3 (30) 44.4 (160) 125 8.3 (30) 44.4 (160) 125 8.3 (30) 44.4 (160) Pa Pa 50 - 200 70 - 200 50 - 200 70 - 200 50 - 200 70 - 200 Monobloc 6-row coil: • No. of rows - Cooling - Heating • No. of passes: - Cooling - Heating • Water content - Cooling - Heating Electric heater • Maximum capacity • Current draw ± 15% • VDE, CE, UL and CSA approved • Power input at zero flow Fan • Forward-curved blade centrifugal fan, single wheel: • Max. air flow • Static pressure at nominal air flow*** (without electric heater) Fan motor 230 V - 1 ph - 50 Hz, 2-pole asynchronous, permanent capacitor, inherent overload protection, class B insulation, varnish class F, IP 44 • Maximum power input at 230 V*** • Minimum output voltage from electronic speed controller • Nominal current*** • Starting current Air filter Throwaway, 55 mm thick, fire rating medium M1, metal frame • Dimensions mm • High efficiency filter type F5 • Pressure drop, clean, nominal air flow Pa Fresh air connection: • Outside diameter • Constant minimum air flow (-10% ; + 20%) • Constant maximum air flow (-10% ; + 20%) • ∆P (upstream/downstream) - Controller at 8.3 l/s (30 m3/h) - Controller at 44.4 l/s (160 m3/h) ICM Water connections ICM modules are designed and tested for 16 bar operating pressure. The total operating circuit of the ICM is guaranteed for an operating pressure of 10 bar. Contact your local Carrier representative for advice when an application calls for an operating pressure of 16 bar. Legend: * Based upon water entering at 6°C, room air at 25°C dry bulb, 50% relative humidity, 5 K ∆T and nominal air flow. ** Based upon water entering at 50°C, room air at 19°C, 10 K ∆T and nominal air flow. *** Refer to extended electrical data table 6 2.2 - Dimensional drawings 2.2.1 - Required service space, mm Size 1.3 REMOVABLE DRAIN PAN AND COIL ASSEMBLY FILTER ACCESS SIDE DOOR FAN MOTOR ACCESS DOOR CLEARANCE FOR LOWER FILTER ACCESS PANEL Size 2.3 REMOVABLE DRAIN PAN AND COIL ASSEMBLY FILTER ACCESS SIDE DOOR FAN MOTOR ACCESS DOOR CLEARANCE FOR LOWER FILTER ACCESS PANEL 7 2.2 - Dimensional drawings (continued) 2.2.1 - Required service space, mm Size 4.4 REMOVABLE DRAIN PAN AND COIL ASSEMBLY FILTER ACCESS SIDE DOOR FAN MOTOR ACCESS DOOR CLEARANCE FOR LOWER FILTER ACCESS PANEL 8 2.2 - Dimensional drawings (continued) 2.2.2 - Dimensions, mm Size 1.3 PRESSURE TAP ON FLOW MEASUREMENT DIAPHRAGM Ø 16 CONDENSATE OUTLET FRESH AIR OPTION (DOWNSTREAM FROM COIL) GROMMET DETAIL ITEM 1 PTC ELECTRIC HEATER Legend: 1. Suspension lugs 2. Coil hot/chilled water 3. Speed controller or controller 4. Air filter 5. Hot/cold water supply and return connections 6. Fresh air connection 7. Return air connection 8. Supply air duct connection 9. Water flow control valves 10. Filter access door 11. Fan access door 12. Fan/motor assembly 13. Recyclable condensate drain pan 14. Electric heater Size 2.3 PRESSURE TAP ON FLOW MEASUREMENT DIAPHRAGM Ø 16 CONDENSATE OUTLET FRESH AIR OPTION (DOWNSTREAM FROM COIL) GROMMET DETAIL ITEM 1 Legend: 1. Suspension lugs 2. Coil hot/chilled water 3. Speed controller or controller 4. Air filter 5. Hot/cold water supply and return connections 6. Fresh air connection 7. Return air connection 8. Supply air duct connection 9. Water flow control valves 10. Filter access door 11. Fan access door 12. Fan/motor assembly 13. Recyclable condensate drain pan 14. Electric heater 9 2.2 - Dimensional drawings (continued) 2.2.2 - Dimensions, mm Size 4.4 PRESSURE TAP ON FLOW MEASUREMENT DIAPHRAGM 110 9 1100 157.5 207.5 345 Ø 249 155 600 86 84 1040 7 8 125 110 Ø 8.5 600 DETAIL ITEM 1 220 Ø 8.5 650 GROMMET Ø 124 14 6 11 4 2 12 25 3 FRESH AIR OPTION (DOWNSTREAM FROM COIL) Ø 16 CONDENSATE OUTLET 1 13 5 660 720 1000 10 211 10 24 Ø1 Legend: 1. Suspension lugs 2. Coil hot/chilled water 3. Speed controller or Zone Controller 4. Air filter 5. Hot/cold water supply and return connections 6. Fresh air connection 7. Return air connection 8. Supply air duct connection 9. Water flow control valves 10. Filter access door 11. Fan access door 12. Fan/motor assembly 13. Recyclable condensate drain pan 14. Electric heater 3 - SAFETY CONSIDERATIONS 3.3 - General installation recommendations 3.1 - General IMPORTANT: The controller, power module, controls loops with speed controllers or in general units fitted with controls loops must have an isolating device upstream (for example a double-pole circuit breaker). If necessary, an easily operated emergency stop device (such as a punch-button switch) must cut off the power to all equipment. These safety devices shall be sized and installed in accordance with IEC Recommendation 364, corresponding to Europe HD 384, France NFC 15 100 and UK IEE Wiring Regulations. These devices are not supplied by Carrier. Installing, commissioning and servicing of the various components which make up the different control loops can be dangerous unless certain aspects of the installation, such as the presence of mains electricity and hot or chilled-water in the air conditioning equipment, are taken into account. Only specially trained and qualified technicians and installers who have been fully trained on the product concerned are authorised to install, commission and service this equipment. During servicing work, it is essential to apply all recommendations and instructions given in service leaflets, on labels or in the instructions delivered with the equipment, and to comply with any other relevant instructions. In general terms the following rules must be applied: - Units must be provided with overvoltage protection upstream (not supplied by Carrier) Definition of the pictograms used Upstream overvoltage protection Unit without electric heater T2A Unit with electric heater T16A Electrical Danger - Units must be protected by a differential type earth leakage current device (not supplied by Carrier) Caution hand hazard General Danger Comply with all the safety rules and regulations currently in force. Wear eye protectors and work gloves. Take care when moving or positioning equipment. 3.2 - Precautions against electrocution Only electricians who are qualified to the level recommended by the IEC (International Electrotechnical Commission) in its standard IEC 364, corresponding to Europe HD 384, France NFC 15 100 and UK IEE Wiring Regulations, may have access to electrical components. In particular it is obligatory to disconnect all electrical power supplies to the unit and its accessories before carrying out any work. Disconnect the main power supply with an isolating device (not supplied by Carrier). IMPORTANT: The components, which make up the different control loops described in this manual include electronic items. As such, they may generate or be harmed by electromagnetic interference unless they are installed and used in accordance with these instructions. The components making up these control systems conform to the requirements of electromagnetic compatibility in residential and industrial areas. They also comply with the low-voltage directive. - The power disconnexion device must be clearly labelled to identify which items of equipment are connected to it. - The wiring of the components which make up the different control systems and the communication buses must be carried out in accordance with the latest rules and regulations by professional installers. - The power supply cable must be doubly insulated and fixed using an appropriate cable clamp or the cable clamp supplied with the controller. The cable must be clamped on the outer insulation. - The control loop components must be installed in an environment, which conforms to their index of protection (IP). The maximum level of pollution is normally pollutant (level 2) and installation category II. - The low-voltage wiring (communication bus) must be kept physically separate from the power wiring. - In order to avoid interference with the communication links: • Keep low-voltage wiring away from power cables and avoid using the same cable run (a maximum of 300 mm in common with the 230 VAC, 30 A cable) • Do not pass low-voltage wires through loops in the power cables • Do not connect heavy inductive loads to the same electrical supply (circuit breaker) used by the controllers, power modules or speed controllers. • Use the screened cable type recommended by Carrier and make sure all cables are connected to the controllers and power modules. 3.4 - Conformity This equipment has been declared to be in conformity with the main requirements of the directive by virtue of using the following standards: - Electromagnetic compatibility: 89/336/EEC - Low-voltage directive: 73/23/EEC 11 4 - APPLICATION 4.1 - Multi-zone buildings with varying loads When establishing the thermal load schedule, the following thermal gains and losses in the peripheral areas of the building must be considered: • Losses through the outside walls and glazing • Solar gains and heat gains from lighting, people and machinery (computers, copiers etc.). The concept of the ICM, as an individual comfort module, rests upon its use of two separate fluids which are controlled together to compensate for variations in cooling and heating loads imposed in the peripheral areas of the building. dependent upon the amount of external glazing and the structure of the building. The combined effects of sun, lights and people can change an apparent heating load into a cooling load, even in winter with very low outdoor air temperatures. These varying cooling and heating loads (Fig. 3) show the need for a system which uses two fluids such that it can maintain acceptable conditions in all areas of the building at all times. 4.2 - Cooling Supply air from the 42BJ ICM cools and mixes with outdoor air from a central air handler and is ducted to diffusers (35BD/35SR for example) in the false ceiling of the room. An appropriate volume of chilled, dehumidified air is introduced into the room to compensate for the total gains from the sun, people, lights, machinery and cooling losses. The sensible cooling load to be considered is required to counter the solar gains, lighting gains and gains from people all of which vary with the occupancy and the orientation of the building (Fig. 1). Transmission gains, on the other hand, depend only upon the temperature difference between the interior of the building and the outdoors (Fig. 2). Since the internal and external loads vary, the ICM must vary, automatically, its flow of cooled air so as to maintain constant the air temperature in the conditioned space. Cooling Lights, people and solar gains n tio ec nv o c WEST EAST Heating Sensible heat (W/m2) Outdoor air temperature, time of day, exposure and season together enable the cooling and heating capacities required to be calculated. Thus it is known that the maximum thermal gains in the north hemisphere for rooms with easterly or westerly exposures will arise in July or August. Those with southerly exposures will have their maximum thermal gains in November, Sensibl eat (W/m2) The two fluids are chilled air and heated air which are both generated within the ICM and delivered to strategically positioned diffusers. Outdoor air temperature (°C) Fig 2: Typical building convection load Lights and people Sensibl eat (W/m2) Lights Cooling SOUTH n su Heating s ht lig s nt pa cu oc July Fig. 1: Typical building loads 12 ion ct ve n co Outdoor air temperature (°C) Fig 3: Typical air conditioning load 4.3 - Heating When the heat losses exceed the internal gains from people, lights etc, the supply air from the ICM increases proportionally to maintain the selected setpoint. 4.4 - Air distribution Carrier linear diffusers are recommended to be used with the ICM. They have an internal movable damper controlled by an internal thermostat (calorstat). Movement of the damper changes the direction of the air flow from the diffuser. When the temperature of the air from the diffuser is higher than 24°C, the air flow is directed towards the window. When it is lower than 20°C, the air flow is directed towards the interior of the space. The diffuser has three air delivery slots, one discharges warm air towards the window, the other direct cold air towards the interior of the room. ICM provides warm or cold air supply paths an return air path. Carrier recommends a double plenum in galvanized steel insulated on the inside with a 13 mm fibre wool blanket which itself is protected against erosion by the air flow with a neoprene skin. Both compartments of the plenum have a round lateral connection spigot to which the supply and return air ducts are connected. The ducts may be flexible or semi-rigid and are insulated to prevent thermal gains and losses within the ceiling void and to attenuate any noise which could be distributed around the building from their surface. Duct runs through the ceiling void should be as short and as straight as possible to reduce pressure losses, heat gains and losses and to minimise the risk of noise nuisance from the air flows. NOTE: Other Carrier linear diffusers can be used. Refer to the 35BD/35SR Product Data. When considering diffusers from other manufacturers, remember that Carrier diffusers maintain the Coanda effect with as little as 15% of the nominal air flow. Heating air flow Cooling air flow Air distribution with Carrier Optimix linear diffusers 5 - SYSTEM DESCRIPTION diversity factor and variable loads deriving from the exposure of the building and the individual room and zone loads. 5.1 - Air conditioning system An air conditioning system which uses 42BJ ICMs can comprise an air handling unit, to handle the outdoor air, one or more water chillers, an air distribution system for the primary air from the air handling unit, one or more heating devices (heat pumps or boilers), chilled water and hot water distribution systems, 42BJ ICMs and linear diffusers to deliver the air to the individual room or zones. 5.2 - Water chiller Any Carrier water chiller can be used with 42BJ ICMs. Chilled water for the fan coils and for the central air handling unit can be supplied from the same chiller. The chiller is selected with the cooling and heating load estimates as its basis. 5.3 - Fresh air handling unit This is the central air handler which provides the total fresh air supply required to supply all the 42BJ ICMs. It is usual to allow 7-8.3 l/s (25-30 m3/h) of fresh air for each room occupant in the conditioned space. The fresh air supplied to each fan coil will be at a constant flow rate and temperature with the temperature only being reset at seasonal changeovers. These air handling unit are usually monobloc units. That is, they are supplied from the factory as a fully assembled, complete unit with a chilled water coil, a hot water coil or an electric heater, a return air filter with an efficiency rating to satisfy local codes with respect to air supplied to the type of activity under consideration, and a fan and motor assembly to drive the air through the distribution ductwork. An integral control system can set and maintain the supply air temperature. For example, if the total cooling load is 650 kW the chiller will be selected to supply this load taking account also of the 13 6 - MAIN COMPONENTS OF THE ICM The fan motor assembly is the main component of the unit. In the ICM size 1 it can have a capacity of 144 l/s (520 m3/h). ICM size 2 can have only one fan motor with a capacity of 189 l/s (680 m3/h). The capacity of the size 4 is 950 m3/h (264 l/s). NOTE: In order to simplify maintenance, the motorised fan is held in position by three lugs and one screw. Electrical connections use a quick connector to prevent wiring errors and significantly reduce maintenance time. IMPORTANT: If the ICM is fitted with a return air temperature sensor, the constant fresh air flow rate must not exceed 50% of the air flow rate delivered by the unit at minimum speed. NOTE: To operate correctly, the 8.3 l/s or 30 m3/h constant fresh air flow controller requires a differential pressure in the range 50 Pa to 200 Pa. The 16.6 l/s or 60 m3/h constant fresh air controller requires a differential pressure in the range 70 Pa to 200 Pa. 6.2 - Filter and access 6.1 - Fresh air controller The 42BJ ICM is fitted with a high efficiency F5 type filter. The ICM unit can be fitted with a constant fresh air flow controller allowing the number of air changes to be controlled accurately. It is vital to choose the correct constant fresh air flow controller for the use to which the room or zone concerned will be put. The following range of controllers is available: - 8.3 l/s or 30 m3/h (- 10%; + 20%) - 16.6 l/s or 60 m3/h (- 10%; + 20%) The fresh air supply is located upstream of the water coil. The 125 mm collar which houses the flow controller is made of ABS. The 16.6 l/s or 60 m3/h fresh air controller may be modified on site by relocating or removing two plastic restricters in order to increase its constant fresh air flow capacity to a maximum of 44.4 l/s or 160 m3/h. A label on the ICM shows how to readjust the two plastic restricters. FRESH AIR CONTROLLER 14 Fire rating medium M1, metal frame Three filter access options are provided on the ICM: • From above for units in false floor voids • From below for units in false ceiling voids • From the side (all applications) 6.3 - Water coil The water coil has aluminium fins mechanically bonded to 3/8" diameter copper tubes by expansion. Water inlet and outlet connections are threaded 1/2" gas. Air purge valves are standard. The coil is integral with the drain pan and coil access door to ease removal for service. Coils available are: • 5 rows for two-pipe systems with changeover or for use with electric heater. • 6 rows with 5 rows cooling and 1 row heating. • Nitrate [NO3-] • Dissolved iron • Dissolved oxygen • Carbon dioxide [CO2] • Resistivity • pH = 0 mg/l < 0.5 mg/l 4 < [O2] < 9 mg/l < 30 mg/l 2000<Resistivity<5000 Ωcm 6.9 < pH < 8 6.5 - PTC electric heater (positive temperature coefficient) These are high-performance PTC electric heaters which make use of two technologies: electric heating and surface temperature limitation (a state-of-the-art technology based on the use of ceramics). The true dissipated power is then dependent on the temperature and flow rate of the incoming air. The technology ensures totally safe self-regulation of the dissipated power. In addition, each electric heater is fitted with a self-resetting safety thermostat of the normally closed type which cuts out when the temperature rises to 70°C with an average differential of 20°C. 6.4 - Thermoformed ABS condensate pan, 3 mm thick CAUTION: It is vital to disconnect the ICM from the general power supply before carrying out any work on the electric heater. The main pan is below the coil with an auxiliary below the valves. The monobloc construction prevents leaks. With the coil on the suction side of the fan to facilitate drainage, condensate has to be drained through a non-return flap valve. The difference in height between the main and auxiliary drain pans is enough to overcome the depression within the unit and dispenses with the need for an in-built siphon. The auxiliary pan is insulated with 4 mm foam. The drain stub itself has 16 mm external diameter. 6.6 - Flow measurement device A diaphragm in the return air spigot measures the return air flow through the unit. Recommended coil water quality At installation handover, and then periodically every year, it is advised to analyse the water for bacteria (detection of ferrobacterias, H2S producing and sulphate reducing bacteria) and chemicals (in order to avoid problems due to corrosion and scaling). The water circuit must include all the necessary elements for the treatment of the water: filters, additives, intermediate exchangers, purges, drains, isolating valves, etc., according to the analysis results. The total air flow through the unit is the sum of the return air flow and the fresh, ventilation, air flow. The measuring diaphragm is both reliable and accurate and gives a quick, noise-free indication of the air flow. Connect an electronic manometer and interpolate on the diagram stuck to the unit to obtain the actual air flow (flow tolerance ± 20%). NOTE: A straight length, upstream of the diaphragm, of at least 4 duct diameters is essential in order to obtain an accurate air flow reading. The results must be in accordance with the values shown below: • Total hardness in French degrees:10 < TH < 15 • Chloride [CL-] < 10 mg/l • Sulphate [SO42-] < 30 mg/l 15 7 - CARRIER ELECTROMECHANICAL CONTROLLER WITH FAN SPEED CONTROLLER 7.1 - Description The basic version of the ICM is fitted with an electromechanical controller with a fan speed controller developed by Carrier. This speed controller has two different control inputs (preselected speed or 0-10 V according to choice), making it highly flexible and fully responsive. Each 42BJ ICM has a water flow control valve or valves of the “on/off ” type, flexible water pipes to simplify the connection of units to the primary hot and/or chilled water circuits, and in appropriate cases a power relay for controlling the electric heater. The optional electromechanical controller also includes a male-female quick connect terminal block for connecting the various cables that come from the three-speed fan motor, the valve actuators, the electric heater power relay and, if appropriate, from the heating/cooling changeover configuration switch for 42BJ ICMs fitted with a single “hot or cold” coil. The male-female quick connect terminal block and the electric heater power relay are mounted on a DIN rail and protected by an ABS cover. The DIN rail is made large enough to accept a bipolar disconnecting switch and integral fuse holder, not supplied by Carrier (contact your Carrier representative). The quick connect terminal block and flexible water pipes will be appreciated when servicing work is being carried out, since they enable service times to be significantly reduced. Replacing or moving a unit becomes a simple matter. A wall-mounted room thermostat can be supplied with the ICM as an accessory. This thermostat will be connected directly to the female side of the quick connect terminal block (see section describing room thermostats). Wiring diagrams 16 7.2.2 - Control input 0-10 V d.c. 7.2 - Speed controller Control voltage This signal has two operating bands: • between 0 and 2 V (± 150 mV), the output is zero • between 2 V (± 150 mV) and 10 V, the output ranges from 80 V (± 15 V) to 225 V (± 15 V), for an input voltage of 230 V a.c. Supply network (supply to fan motor) WARNING: Only one of the 2 different control inputs should be selected, otherwise the fan speed controller will be damaged. Input 230 VAC - 50 Hz 7.3 - General characteristics Factory— wired Field— wired Blue Adjustable potentiometers 0—10V Input Screening 7.2.1 - Inputting a preselected speed This input gives three speed settings to the speed controller. The speeds are each adjustable by a potentiometer on the face of the controller. Setting the speed is achieved when the supply power is applied to one of the 3 input pre-selections. Speed control potentiometer ranges are: - low speed 80 to 120 V (± 15 V) - medium speed 110 to 170 V (± 15 V) - high speed 160 to 225 V (± 15 V) Selection of inputting a preselected speed or control input 0 to 10 V is automatic. A LED on the face of the controller shows when it is on. NOTE: Note that the controller has a circuit which forces the selection of high speed for two seconds when: • Power is switched on • An input control signal from 0 to 10 V at a level higher than 2 V is established • A speed is selected • Power supply: 230 V ± 10% • Output voltage range: 80 to 225 V (± 15 V) • Screw terminal connections: size 2 x 1.5 mm2 • Full load starting capability • Overload capacity: + 50% of maximum power for one minute • DIN enclosure, 12 screw terminals • IP 201 protection • Operating environment: + 5°C to + 40°C, 85% to 40% RH • Power input 2.5 VA • CE compliance: - in accordance with EMC directive 89/336/EEC, - in accordance with low-voltage directive 73/23/EEC dated 19/02/73 as amended by directive 93/68/EEC dated 22/07/93. The output ranges are given for a supply network input voltage of 230 V a.c. (RMS). 17 7.4 - The various ICM configurations available Each ICM can be fitted with one or two on/off valves, two or three ways and flexible water pipes, depending how the unit is configured. NOTE: The features of the valves and flexible pipes are given in the chapter called “Technical specifications”. 7.4.1 - The ICM is fitted with a 5-row cooling coil which operates in cooling mode only (2 pipes). Operates in “cooling” mode only. This option includes a speed controller, a 2-way on/off valve and two insulated flexible water pipes. 5-row cooling coil Speed 1 (LS) Speed 2 Speed 3 (HS) Cooling valve open L: Thermostat supply (230 V a.c.) Cooling valve N: Thermostat supply (230 V a.c.) Fan Blue 6 x 0.75 mm2 Supply: 230 V, 50 Hz, 1 phase 3G1, 5 mm2 Protection: T2A 18 7.4.2 - The ICM is fitted with a 5-row cooling or heating coil (2 pipes with changeover). Operates in cooling or heating mode. This application is of the heat pump type. This option includes a speed controller, a 3-way on/off valve, a heating/cooling changeover switch and two insulated flexible water pipes. 5-row cooling coil with heating/cooling changeover Speed 1 (LS) Speed 2 Speed 3 (HS) Changeover Cooling valve Heating valve L: Thermostat supply (230 V a.c.) N: Thermostat supply (230 V a.c.) Fan Blue 7 x 0.75 mm2 Supply: 230 V, 50 Hz, 1 phase 3G1, 5 mm2 Protection: T2A 7.4.3 - The ICM is fitted with a 5-row cooling coil and a 1-row heating coil (4 pipes). Operates in cooling and heating mode in sequence. This option includes a speed controller, two 2-way on/off valves, and 4 flexible water pipes, 2 of which are insulated and 2 uninsulated. 5-row cooling coil and 1-row heating coil Speed 1 (LS) Speed 2 Speed 3 (HS) Cooling valve open Heating valve open L: Thermostat supply (230 V a.c.) Heating valve N: Thermostat supply (230 V a.c.) Fan 7 x 0.75 mm2 Blue Cooling valve Supply: 230 V, 50 Hz, 1 phase 3G1, 5 mm2 Protection: T2A 19 7.4.4 - The ICM is fitted with a 5-row cooling coil and an electric heater (2 pipes and 2 wires). Operates in cooling mode or heating mode with electric heater in sequence. This option includes a speed controller, a 2-way on/off valve, 2 insulated flexible water pipes and 1 power relay for controlling the electric heater. 5-row cooling coil with heating/cooling changeover Speed 1 (LS) Speed 2 Cooling valve Speed 3 (HS) Cooling valve open Electric heater control L: Thermostat supply (230 V a.c.) N: Thermostat supply (230 V a.c.) Fan 6 x 0.75 mm2 Blue Relay Electric heater Supply: 230 V, 50 Hz, 1 phase 3G1, 5 mm2 Protection: T2A NOTE: The speed controller, the power relay for controlling the electric heater, as well as the terminal box are protected by a plastic cover. 20 7.5 - Technical specification for the heating/cooling changeover switch The heating/cooling changeover switch is designed to be installed straight onto the couplings of the 3-way valves on the ICM. It detects temperature changes in the fluid circulating in the primary water circuit. A changeover switch operates according to the water temperature in accordance with the diagram below. WIRE LENGTH: 1000 mm Features: • steel body and clip • leak proof • interrupting current - 5 A at 230 Va.c. with resistive load - 2.9 A at 230 Va.c. with inductive load • temperature range 18.3 - 29.4 °C • differential 11.1 K ± 3.3 When a heating/cooling changeover switch is connected between the room thermostat and the water flow control valve, the changeover between heating and cooling modes takes place automatically in accordance with the following diagram. HM CM ∆: Differential 11.1 K ± 3.3 CM: Cooling Mode HM: Heating Mode θ: Water temperature in °C 7.6 - Room thermostats The 42BJ ICM cam be controlled by a Carrier room thermostat, but also by Carrier numeric controllers, installed on the 42BJ ICM and tested in the factory. On special request other types of controllers can be factory-installed on the units (supplied by Carrier or by the customer). Carrier room thermostat CONTROL Other controls available on request from the factory NOTE : For further details on the Carrier controllers, mentioned above, please refer to the technical documentation on each of these controllers. 21 8 - CARRIER NUMERIC CONTROLLER At the top of the range, ICMs will be fitted with a Carrier communicating numeric controller with programmable parameters. The controller will be attached directly to each ICM. The control system will then consist of the following: a Carrier numeric controller, - one or two water flow control valves, depending how the ICM is configured, complete with their flexible water pipes, - a user interface or wall-mounted thermostat located in the air conditioned zone from which commands can be sent to the controller (available as accessories), - a Power Module (Pm) for controlling lights and window blinds in the air conditioned zone (available as an accessory) can be added to the system to further enhance comfort. Depending on the required configuration, a room temperature sensor (available as an accessory) and/or a changeover sensor (optional) may be supplied. Most of electrical connections use quick connectors to simplify maintenance work and reduce servicing costs. The controller is available with the following functions: Two pipes - Two pipes with changeover - Four pipes - Two pipes/two wires - Two pipes/two wires with changeover (please consult your Carrier representative for this application) The main functions of the controller are: Controlling room temperature. Temperature is measured either by the temperature sensor incorporated in the user interface or wall-mounted thermostat, or by a room temperature sensor. - Selecting occupied or unoccupied mode through the user interface or wall-mounted thermostat. - Controlling the occupied setpoint through the user interface or wall-mounted thermostat. - Controlling room air renewal (available through the user interface only). - Halting the control function if an open window is detected (the parameters for this function are programmable). If a Power Module is associated with the controller, the following additional functions are accessible from the user interface: Turning a lighting source on or off, - Turning a controlled output on or off, - Raising, lowering and adjusting the angle of window blinds. For complete information on the Carrier numeric controller (Maestro) consult the specific documentation (order No. 18173-76). 22 9.1.2 - Two-way valve body 6.5 mm 9.1 - Valves Note that whether the type of controller used is electromechanical or numerical, the valve body + actuator assembly is identical. 6.5 mm travel 9 - TECHNICAL SPECIFICATIONS 9.1.1 - Electrothermal actuator (on/off type) This on/off type of actuator is used with the electromechanical controller and with the Carrier numeric controller. 9.1.1.1 - Features • Compact design • Long lasting • Easy installation without toolkit • Completely silent in operation • Complete with connector cable 9.1.1.2 - Operation Linear movement is controlled by expansion and contraction of a wax element heated by an electrical resistor. 9.1.1.3 - Specifications Power supply Inrush current Holding current Power Maximum travel Operating temperature Degree of protection Opening time Closing time Connection cable Dimensions Permitted differential pressure 230 V a.c. (± 15%) - 1 ph-50 Hz) 0.7 A 0.013 A 3W 8 mm 0 to 50°C IP43 if installed vertically IP40 if installed horizontally 4 min. Maximum 7 min. depending on actuator heating-up time (ambient temperature 20°C) 1 m, 2 x 0.75 mm2 Diameter 50 mm Height 68.5 mm 1.5 bar (3-way valve) 2.5 bar (2-way valve) 9.1.2.1 - Features • G1/2” flat-joint thread • Straight valve body in non-nickel plated Rg5 bronze with arrow indicating direction of flow embossed on valve body. • Stainless steel stem • Brass valve • MEPD seating joint (modified ethylene-propylene-diene) • Nominal size 15 • Kvs value: 1 • Fluid: water and water glycolated to max. 40% • Temperature: 2-90°C • Leak rate: 0.02% of Kvs • Travel: 6.5 mm • Closing height: 18 mm • Flow curve: linear • Maximum pressure: PN 16 bar 9.1.2.2 - Pressure drop See chapter 11.4. 23 9.2 - Flexible water pipes 6.5 mm travel 9.1.3 - Three-way valve body 9.1.3.1 - Features 9.2.1 - Materials • Pipes: MEPD-based elastomer (modified ethylenepropylene-diene) • G1/2” flat-joint thread • Braid: 304L stainless steel • Valve body in non-nickel plated Rg5 bronze with arrow indicating direction of flow engraved on valve body. • Insulation: cell foam rubber to M1 fire rating (chilled water pipes only, 9 mm thick). • Stainless steel stem • Brass valve • MEPD seating joint 9.2.2 - Features • Minimum bending radius: 35 mm non-insulated, 75 mm insulated • Nominal size 15 • • Kvs value: flow A-AB = 1, bypass B-AB = 0.63 • Fluid: water and water glycolated to max. 40% The flexible water pipes are designed to carry treated or untreated water (maximum 40% concentration of ethylene glycol or propylene glycol). • Temperature: 2-90°C • Maximum hot water temperature 90°C • Leak rate: 0.02% of Kvs • Operating pressure: 16 bar • Travel: 6.5 mm • Test pressure: 24 bar • Closing height: 18 mm • Connections: 1/2” BSP threaded nut • Flow curve: percentage A-AB, linear for bypass B-AB • Length: 1 m for the pipes connected to the coil and 930 mm for those connected to the water valves. • Nominal pressure: PN 16 bar 9.1.3.2 - Pressure drop See chapter 11.4. 24 10 ACCESSORIES 10.2 - Carrier numeric controller accessories A broad range of accessories is available to allow the ICM to be installed in a wide range of applications. 10.2.1 - Condensate drain pump 10.1 - Electromechanical controller accessories A 42BJ ICM can be fitted with a condensate drain pump, preferably before but if necessary after the unit has been installed in a false floor or ceiling. 10.1.1 - Electromechanical room thermostat for operating in heating mode only or cooling mode only With setback for two-pipe systems with three-speed fan control and on/off switch. 10.1.2 - Electromechanical room thermostat for operating in heating mode and cooling mode (manual) With setback for two-pipe systems with changeover, four-pipe systems or two or four-pipe systems with electric heater, it has a two-position manual switch for summer/winter setting, three speed fan control and on/off switch. 10.1.3 - Electromechanical room thermostat for operating in heating mode and cooling mode (automatic) 10.2.1.1 - Introduction 10.2.1.2 - Operation See Installation, Operation and Maintenance Instructions, order No. 14218-76. 10.2.2 - Adjustable feet for installing an ICM in a false floor A 42BJ ICM may be installed in a false floor. Adjustable feet are available as optional extras intended to be fitted on site. For further information please contact your local representative. 10.2.2.1 - Procedure for fitting With setback for two-pipe systems with changeover, four-pipe systems or two or four-pipe systems with electric heater, it has a three-speed fan control and on/off switch.There is a 1 K dead band between the heating stage and the cooling stage. HIGH POSITION HIGH POSITION LOW POSITION Fixing holes for adjustable feet 25 11 - 42BJ ICM PERFORMANCES 11.1 - Cooling capacities - cold water coil, kW 11.1.1 - Size 1.3, 5-rows cooling 6-11 7-12 8-13 10-15 Air flow, l/s (m3/h) 55.5 (200) 83.3 (300) Data type** Water temp. in-out* Relative humidity 40 % TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE kW kW °C l/h kW kW °C l/h kW kW °C l/h kW kW °C l/h 94.4 (340) 111.1 (400) 125.0 (450) 139.0 (500) 153.0 (550) 167.0 (600) Entering air dry bulb temperature, °C 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 1.11 1.01 9.7 191 0.96 0.94 10.7 164 0.94 0.94 10.8 162 0.82 0.82 12.7 140 1.35 1.35 10.1 232 1.25 1.25 11.0 214 1.14 1.14 12.0 196 0.93 0.93 13.8 160 1.04 1.04 10.0 179 0.93 0.93 10.9 161 0.83 0.83 11.7 143 0.62 0.62 13.6 107 1.90 1.90 10.7 327 1.78 1.78 11.6 306 1.66 1.66 12.5 285 1.41 1.41 14.3 243 1.53 1.53 10.6 263 1.41 1.41 11.5 242 1.29 1.29 12.4 221 1.04 1.04 14.2 179 1.16 1.16 10.4 200 1.04 1.04 11.3 179 0.92 0.92 12.2 158 0.69 0.69 13.9 118 2.09 2.09 11.0 359 1.95 1.95 11.9 336 1.82 1.82 12.8 313 1.54 1.54 14.6 266 1.67 1.67 10.9 288 1.54 1.54 11.8 264 1.40 1.40 12.7 241 1.13 1.13 14.5 194 1.26 1.26 10.7 217 1.13 1.13 11.6 194 0.99 0.99 12.5 171 0.73 0.73 14.2 126 2.27 2.27 11.3 391 2.12 2.12 12.2 365 1.97 1.97 13.1 340 1.67 1.80 15.1 309 1.81 1.81 11.2 312 1.66 1.66 12.1 286 1.51 1.51 13.0 260 1.21 1.29 15.0 222 1.35 1.35 11.0 233 1.20 1.20 11.9 207 1.06 1.06 12.7 182 0.77 0.81 14.6 139 2.45 2.45 11.5 422 2.29 2.29 12.4 394 2.26 2.13 13.3 366 1.80 1.80 15.1 309 1.95 1.95 11.4 335 1.78 1.78 12.3 306 1.51 1.62 13.2 278 1.29 1.29 15.0 222 1.44 1.44 11.2 248 1.28 1.28 12.1 220 1.06 1.12 13.0 193 0.81 0.81 14.6 139 2.63 2.63 11.8 452 2.45 2.45 12.7 422 1.97 2.27 13.5 391 1.92 1.92 15.3 391 2.08 2.08 11.7 357 1.90 1.90 12.5 326 1.51 1.72 13.4 296 1.36 1.36 15.2 296 1.53 1.53 11.5 262 1.35 1.35 12.3 232 1.06 1.18 13.2 203 0.84 0.84 14.8 203 0.88 0.88 8.8 152 0.82 0.82 9.7 141 0.76 0.76 10.6 131 0.63 0.63 12.5 109 0.70 0.70 8.6 121 0.64 0.64 9.5 110 0.57 0.57 10.5 99 0.44 0.44 12.5 76 1.49 1.44 10.5 257 1.41 1.41 10.8 242 1.31 1.31 11.8 226 1.13 1.13 13.6 194 1.22 1.22 9.8 211 1.13 1.13 10.7 195 1.04 1.04 11.6 179 0.85 0.85 13.5 147 0.95 0.95 9.6 163 0.86 0.86 10.5 148 0.77 0.77 11.4 132 0.58 0.58 13.3 99 1.64 1.61 10.7 282 1.56 1.56 11.1 268 1.45 1.45 12.1 250 1.25 1.25 13.9 214 6-11 7-12 8-13 10-15 Air flow, l/s (m3/h) 55.5 (200) 83.3 (300) Data type** Water temp. in-out* Relative humidity 50 % TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE kW kW °C l/h kW kW °C l/h kW kW °C l/h kW kW °C l/h 94.4 (340) 111.1 (400) 125.0 (450) 139.0 (500) 153.0 (550) 167.0 (600) Entering air dry bulb temperature, °C 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 1.46 1.02 9.6 251 1.30 0.95 10.7 223 1.13 0.88 11.7 195 0.78 0.74 13.8 135 1.38 1.28 10.7 238 1.25 1.23 11.2 214 1.14 1.14 12.0 196 0.93 0.93 13.8 160 1.04 1.04 10.0 179 0.93 0.93 10.9 161 0.83 0.83 11.7 143 0.62 0.62 13.6 107 2.60 1.89 10.7 446 2.26 1.75 11.8 389 1.90 1.60 12.9 327 1.41 1.41 14.3 243 1.54 1.46 11.1 265 1.41 1.41 11.5 242 1.29 1.29 12.4 221 1.04 1.04 14.2 179 1.16 1.16 10.4 200 1.04 1.04 11.3 179 0.92 0.92 12.2 158 0.69 0.69 13.9 118 2.88 2.09 10.9 495 2.50 1.94 12.0 429 2.08 1.77 13.1 358 1.54 1.54 14.6 266 1.67 1.60 11.3 287 1.54 1.54 11.8 264 1.40 1.40 12.7 241 1.13 1.13 14.5 194 1.26 1.26 10.7 217 1.13 1.13 11.6 194 0.99 0.99 12.5 171 0.73 0.73 14.2 126 3.15 2.29 11.1 541 2.72 2.12 12.2 469 2.26 2.09 13.3 389 1.67 1.67 14.9 288 1.79 1.74 11.6 308 1.66 1.66 12.1 286 1.51 1.62 13.0 260 1.21 1.21 14.8 208 1.35 1.35 11.0 233 1.20 1.20 11.9 207 1.06 1.12 12.7 182 0.77 0.77 14.4 133 3.41 2.48 11.4 586 2.95 2.30 12.4 508 2.43 2.09 13.5 418 1.80 1.80 15.1 309 1.91 1.88 11.8 329 1.78 1.78 12.3 306 1.62 1.62 13.2 278 1.29 1.29 15.0 222 1.44 1.44 11.2 248 1.28 1.28 12.1 220 1.12 1.12 13.0 193 0.81 0.81 14.6 139 3.66 2.67 11.6 630 3.17 2.47 12.6 546 2.26 2.62 13.7 451 1.92 1.92 15.3 451 2.04 2.01 12.0 350 1.90 1.90 12.5 326 1.51 1.72 13.4 296 1.36 1.36 15.2 296 1.53 1.53 11.5 262 1.35 1.35 12.3 232 1.06 1.18 13.2 203 0.84 0.84 14.8 203 0.97 0.82 9.7 167 0.82 0.75 10.7 141 0.76 0.73 11.0 131 0.63 0.63 12.5 109 0.70 0.70 8.6 121 0.64 0.64 9.5 110 0.57 0.57 10.5 99 0.44 0.44 12.5 76 2.04 1.46 10.3 351 1.79 1.36 11.3 308 1.52 1.25 12.4 262 1.13 1.11 13.9 194 1.27 1.15 10.5 219 1.13 1.10 11.1 195 1.04 1.04 11.6 179 0.85 0.85 13.5 147 0.95 0.95 9.6 163 0.86 0.86 10.5 148 0.77 0.77 11.4 132 0.58 0.58 13.3 99 2.27 1.64 10.4 390 1.98 1.52 11.5 341 1.62 1.37 12.8 279 1.25 1.23 14.0 214 6-11 7-12 8-13 10-15 * ** Air flow, l/s (m3/h) 55.5 (200) 83.3 (300) Data type** Water temp. in-out* Relative humidity 60 % TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE kW kW °C l/h kW kW °C l/h kW kW °C l/h kW kW °C l/h 94.4 (340) 111.1 (400) 125.0 (450) 139.0 (500) 153.0 (550) 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 1.81 1.02 9.5 311 1.65 0.96 10.6 284 1.49 0.89 11.6 256 1.13 0.75 13.7 194 1.90 1.29 10.6 327 1.61 1.17 11.7 277 1.31 1.05 12.7 225 0.93 0.91 14.0 160 1.04 0.95 10.7 179 0.93 0.91 11.1 161 0.83 0.83 11.7 143 0.62 0.62 13.6 107 3.34 1.93 10.4 575 3.03 1.79 11.4 521 2.69 1.66 12.5 462 1.90 1.36 14.7 328 2.16 1.49 10.9 372 1.82 1.35 11.9 312 1.46 1.21 13.0 251 1.04 1.04 14.2 179 1.13 1.07 11.0 195 1.04 1.04 11.3 179 0.92 0.92 12.2 158 0.69 0.69 13.9 118 3.70 2.13 10.7 637 3.36 1.99 11.6 579 2.98 1.84 12.7 512 2.10 1.50 14.9 361 2.38 1.65 11.1 410 1.98 1.48 12.1 341 1.57 1.32 13.2 270 1.13 1.13 14.5 194 1.20 1.17 11.3 207 1.13 1.13 11.6 194 0.99 0.99 12.5 171 0.73 0.73 14.2 126 4.05 2.33 10.9 697 3.67 2.17 11.9 631 3.26 2.01 12.9 560 2.28 1.64 15.2 425 2.59 1.80 11.2 446 2.15 1.62 12.3 370 1.69 1.43 13.4 290 1.21 1.21 15.0 222 1.27 1.26 11.5 219 1.20 1.20 11.9 207 1.06 1.06 12.7 182 0.77 0.77 14.6 139 4.37 2.51 11.2 751 3.98 2.35 12.1 684 3.53 2.18 13.0 607 2.47 1.91 15.2 425 2.81 1.94 11.4 483 2.32 1.75 12.5 398 1.80 1.54 13.6 309 1.29 1.39 15.0 222 1.44 1.44 11.2 248 1.28 1.28 12.1 220 1.12 1.12 13.0 193 0.81 0.84 14.6 139 4.64 2.68 11.5 798 4.24 2.52 12.3 730 3.26 3.79 13.2 652 2.66 1.91 15.4 652 3.02 2.09 11.6 519 2.48 1.87 12.7 427 1.69 1.91 13.8 329 1.39 1.39 15.2 329 1.53 1.53 11.5 262 1.35 1.35 12.3 232 1.06 1.18 13.2 203 0.84 0.84 14.8 203 1.26 0.82 9.7 217 1.10 0.75 10.7 189 0.93 0.68 11.8 160 0.58 0.54 13.9 99 0.78 0.63 9.7 134 0.61 0.56 10.8 106 0.57 0.54 11.0 99 0.44 0.44 12.5 76 2.59 1.49 10.0 446 2.35 1.38 11.1 405 2.10 1.27 12.2 360 1.52 1.05 14.4 262 1.72 1.16 10.4 296 1.47 1.05 11.5 253 1.21 0.95 12.5 208 0.85 0.82 13.8 147 Water temperature, inlet-outlet, °C TC - Total cooling capacity, kW SHC - Sensible heat capacity, kW TSA - Air discharge, °C DE - Water flow, l/h 0.97 0.86 10.5 167 0.86 0.81 11.0 148 0.77 0.77 11.4 132 0.58 0.58 13.3 99 2.90 1.66 10.2 498 2.63 1.55 11.2 452 2.33 1.43 12.3 401 1.68 1.17 14.6 289 NOTES: Operating limit: air discharge temperature 12 °C, when the unit is installed where room temperature is 27 °C dry bulb and relative humidity 70 %. To convert l/h to l/s, please divide by 3600. 26 167.0 (600) Entering air dry bulb temperature. °C 25 22 19 25 22 19 25 11.1 - Cooling capacities - cold water coil, kW (cont.) 11.1.2 - Size 2.3, 5-rows cooling 6-11 7-12 8-13 10-15 Air flow, l/s (m3/h) 55.5 (200) 83.3 (300) Data type** Water temp. in-out* Relative humidity 40 % TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE kW kW °C l/h kW kW °C l/h kW kW °C l/h kW kW °C l/h 111.1 (400) 139.0 (500) 153.0 (550) 189.0 (680) 167.0 (600) 194.0 (700) Entering air dry bulb temperature, °C 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 1.24 1.07 8.8 214 1.09 1.00 9.9 187 1.02 0.98 10.2 175 0.89 0.89 11.6 153 1.69 1.69 9.3 291 1.56 1.56 10.3 269 1.44 1.44 11.3 247 1.18 1.18 13.1 204 1.32 1.32 9.3 226 1.19 1.19 10.2 205 1.06 1.06 11.1 183 0.80 0.80 13.0 138 2.39 2.36 10.8 412 2.34 2.34 10.9 402 2.18 2.18 11.8 375 1.86 1.86 13.8 320 2.01 2.01 10.0 346 1.85 1.85 10.9 319 1.69 1.69 11.9 291 1.38 1.38 13.8 237 1.53 1.53 9.9 264 1.38 1.38 10.8 237 1.23 1.23 11.7 211 0.92 0.92 13.6 158 2.90 2.87 10.5 499 2.71 2.71 11.3 466 2.52 2.52 12.3 434 2.14 2.14 14.2 368 2.31 2.31 10.5 398 2.12 2.12 11.4 365 1.93 1.93 12.4 333 1.56 1.56 14.2 268 1.74 1.74 10.4 299 1.55 1.55 11.4 267 1.37 1.37 12.3 235 1.01 1.01 14.0 175 3.21 3.21 10.7 553 3.00 3.00 11.7 516 2.78 2.78 12.6 479 2.35 2.35 14.5 405 2.55 2.55 10.8 438 2.33 2.33 11.7 401 2.12 2.12 12.7 364 1.69 1.69 14.6 291 1.89 1.89 10.8 325 1.68 1.68 11.7 289 1.47 1.47 12.6 253 1.08 1.08 14.3 186 2.90 2.87 10.5 499 2.71 2.71 11.3 466 2.52 2.52 12.3 434 2.14 2.14 14.2 368 2.31 2.31 10.5 398 2.12 2.12 11.4 365 1.93 1.93 12.4 333 1.56 1.56 14.2 268 1.74 1.74 10.4 299 1.55 1.55 11.4 267 1.37 1.37 12.3 235 1.01 1.01 14.0 175 3.29 3.29 10.8 566 3.07 3.07 11.7 528 2.85 2.85 12.7 490 2.41 2.41 14.6 414 2.60 2.60 10.9 448 2.38 2.38 11.8 410 2.16 2.16 12.8 372 1.72 1.72 14.6 296 1.92 1.92 10.9 331 1.71 1.71 11.8 294 1.50 1.50 12.7 258 1.10 1.10 14.4 189 0.96 0.95 7.8 165 0.90 0.90 8.6 154 0.83 0.83 9.6 143 0.70 0.70 11.6 120 0.90 0.68 8.9 155 0.70 0.70 8.6 121 0.63 0.63 9.6 109 0.49 0.49 11.7 85 1.65 1.51 9.7 285 1.53 1.47 10.2 264 1.44 1.43 10.6 247 1.24 1.24 12.5 214 1.35 1.35 8.6 232 1.25 1.25 9.5 216 1.16 1.16 10.5 199 0.96 0.96 22.0 166 1.07 1.07 8.5 184 0.97 0.97 9.4 167 0.87 0.87 10.4 150 0.67 0.67 12.4 115 2.03 1.94 10.3 350 1.95 1.92 10.5 335 1.82 1.82 11.3 313 1.56 1.56 13.2 269 6-11 7-12 8-13 10-15 Air flow, l/s (m3/h) 55.5 (200) 83.3 (300) Data type** Water temp. in-out* Relative humidity 50 % TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE kW kW °C l/h kW kW °C l/h kW kW °C l/h kW kW °C l/h 111.1 (400) 139.0 (500) 153.0 (550) 189.0 (680) 167.0 (600) 194.0 (700) Entering air dry bulb temperature, °C 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 1.58 1.07 8.8 272 1.42 1.00 9.9 244 1.26 0.93 10.9 217 0.91 0.79 13.0 156 1.73 1.55 10.4 298 1.56 1.49 10.9 269 1.44 1.44 11.3 247 1.18 1.18 13.1 204 1.32 1.32 9.3 226 1.19 1.19 10.2 205 1.06 1.06 11.1 183 0.80 0.80 13.0 138 3.40 2.43 10.3 584 2.94 2.24 11.4 506 2.46 2.05 12.6 423 1.86 1.83 14.0 320 2.00 1.87 10.8 344 1.85 1.81 11.2 319 1.69 1.69 11.9 291 1.38 1.38 13.8 237 1.53 1.53 9.9 264 1.38 1.38 10.8 237 1.23 1.23 11.7 211 0.92 0.92 13.6 158 3.98 2.86 10.6 685 3.44 2.63 11.7 591 2.84 2.40 12.9 489 2.14 2.14 14.2 368 2.26 2.16 11.2 389 2.12 2.12 11.4 365 1.93 1.93 12.4 333 1.56 1.56 14.2 268 1.74 1.74 10.4 299 1.55 1.55 11.4 267 1.37 1.37 12.3 235 1.01 1.01 14.0 175 4.44 3.19 10.8 764 3.83 2.94 12.0 659 3.15 2.67 25.0 542 2.35 2.35 14.5 405 2.46 2.39 11.5 424 2.33 2.33 11.7 401 2.12 2.12 12.7 364 1.69 1.69 14.6 291 1.89 1.89 10.8 325 1.68 1.68 11.7 289 1.47 1.47 12.6 253 1.08 1.08 14.3 186 3.98 2.86 10.6 685 3.44 2.63 11.7 591 2.84 2.40 12.9 489 2.14 2.14 14.2 368 2.26 2.16 11.2 389 2.12 2.12 11.4 365 1.93 1.93 12.4 333 1.56 1.56 14.2 268 1.74 1.74 10.4 299 1.55 1.55 11.4 267 1.37 1.37 12.3 235 1.01 1.01 14.0 175 4.56 3.27 10.9 784 3.93 3.01 12.0 675 3.23 2.73 13.2 556 2.41 2.41 14.6 414 2.51 2.44 11.6 432 2.38 2.38 11.8 410 2.16 2.16 12.8 372 1.72 1.72 14.6 296 1.92 1.92 10.9 331 1.71 1.71 11.8 294 1.50 1.50 12.7 258 1.10 1.10 14.4 189 1.11 0.88 8.8 190 0.94 0.81 9.9 163 0.77 0.73 11.0 132 0.70 0.70 11.6 120 0.77 0.74 8.1 132 0.70 0.70 8.6 121 0.63 0.63 9.6 109 0.49 0.49 11.7 85 2.20 1.54 9.5 379 1.95 1.43 10.6 335 1.68 1.31 11.8 290 1.15 1.10 13.9 198 1.44 1.22 9.8 248 1.21 1.13 10.8 208 1.16 1.11 11.0 199 0.96 0.96 12.4 166 1.07 1.06 8.5 184 0.97 0.97 9.4 167 0.87 0.87 10.4 150 0.67 0.67 12.4 115 2.80 1.99 10.0 482 2.45 1.84 11.1 421 2.08 1.68 12.3 358 1.56 1.49 13.7 269 6-11 7-12 8-13 10-15 Air flow, l/s (m3/h) 55.5 (200) 83.3 (300) Data type** Water temp. in-out* Relative humidity 60 % TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE kW kW °C l/h kW kW °C l/h kW kW °C l/h kW kW °C l/h 111.1 (400) 139.0 (500) 153.0 (550) 189.0 (680) 167.0 (600) 194.0 (700) Entering air dry bulb temperature, °C 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 1.94 1.08 8.7 333 1.78 1.01 9.7 306 1.61 0.94 10.8 277 1.26 0.80 13.0 216 2.35 1.57 10.2 405 2.00 1.42 11.4 344 1.65 1.28 12.4 284 1.18 1.11 13.7 204 1.33 1.16 10.4 230 1.19 1.11 10.8 205 1.06 1.05 11.2 183 0.80 0.80 13.0 138 4.39 2.51 9.9 755 3.96 2.31 11.0 681 3.51 2.13 12.1 604 2.47 1.73 14.5 425 2.81 1.91 10.6 484 2.36 1.72 11.7 405 1.89 1.53 12.8 325 1.38 1.34 14.0 237 1.48 1.37 10.9 255 1.38 1.34 11.1 237 1.23 1.23 11.7 211 0.92 0.92 13.6 158 5.17 2.95 10.1 890 4.67 2.74 11.2 803 4.13 2.52 12.3 710 2.87 2.04 14.7 493 3.27 2.24 10.8 563 2.70 2.01 12.0 465 2.13 1.78 13.1 366 1.56 1.56 14.2 268 1.64 1.58 11.2 282 1.55 1.55 11.4 267 1.37 1.37 12.3 235 1.01 1.01 14.0 175 5.76 3.28 10.4 990 5.21 3.05 11.4 896 4.61 2.81 12.5 793 3.19 2.27 14.9 549 3.63 2.49 11.0 625 2.98 2.23 12.2 513 2.31 1.96 13.4 398 1.69 1.69 14.6 291 1.73 1.72 11.5 298 1.68 1.68 11.7 289 1.47 1.47 12.6 253 1.08 1.08 14.3 186 5.17 2.95 10.1 890 4.67 2.74 11.2 803 4.13 2.52 12.3 710 2.87 2.04 14.7 493 3.27 2.24 10.8 563 2.70 2.01 12.0 465 2.13 1.78 13.1 366 1.56 1.56 14.2 268 1.64 1.58 11.2 282 1.55 1.55 11.4 267 1.37 1.37 12.3 235 1.01 1.01 14.0 175 5.90 3.36 10.5 1015 5.34 3.13 11.5 919 4.73 2.88 12.6 813 3.27 2.33 15.0 563 3.73 2.55 11.1 641 3.05 2.28 12.3 525 2.36 2.01 13.4 406 1.72 1.72 14.6 296 1.92 1.87 11.1 331 1.71 1.71 11.8 294 1.50 1.50 12.7 258 1.10 1.10 14.4 189 1.39 0.88 8.8 239 1.23 0.81 9.9 212 1.07 0.74 10.9 183 0.69 0.59 13.2 119 0.90 0.68 8.9 155 0.72 0.60 10.0 125 0.63 0.57 10.6 109 0.49 0.49 11.7 85 2.77 1.56 9.3 476 2.52 1.45 10.4 433 2.25 1.34 11.5 388 1.68 1.11 13.8 289 1.89 1.23 9.7 324 1.63 1.12 10.8 281 1.37 1.01 11.9 236 0.85 0.81 13.9 146 1.15 0.94 9.7 198 0.91 0.83 10.8 156 0.87 0.82 10.9 150 0.67 0.67 12.4 115 3.59 2.03 9.6 617 3.25 1.89 10.8 558 2.88 1.74 11.9 496 2.08 1.42 14.2 357 NOTES: * ** Water temperature, inlet-outlet, °C TC - Total cooling capacity, kW SHC - Sensible heat capacity, kW TSA - Air discharge, °C DE - Water flow, l/h Operating limit: air discharge temperature 12 °C, when the unit is installed where room temperature is 27 °C dry bulb and relative humidity 70 %. To convert l/h to l/s, please divide by 3600. 27 11.1 - Cooling capacities - cold water coil, kW (continued) 11.1.3 - Size 4.4 - 5-rows cooling 6-11 7-12 8-13 10-15 Air flow, l/s (m3/h) 69.0 (250) 97.0 (350) Data type** Water temp. in-out* Relative humidity 40 % TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE kW kW °C l/h kW kW °C l/h kW kW °C l/h kW kW °C l/h 125.0 (450) 153.0 (550) 181.0 (650) 208.0 (750) 236.0 (850) 264.0 (950) Entering air dry bulb temperature, °C 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 1.50 1.31 9.1 258 1.29 1.22 10.2 222 1.20 1.19 10.6 206 1.05 1.05 12.3 180 1.86 1.86 9.7 319 1.72 1.72 10.6 295 1.58 1.58 11.5 271 1.30 1.30 13.4 223 1.44 1.44 9.5 248 1.30 1.30 10.4 224 1.17 1.17 11.3 201 0.88 0.88 13.2 152 2.74 2.64 10.5 471 2.52 2.52 11.2 434 2.35 2.35 12.1 405 2.01 2.01 13.9 347 2.18 2.18 10.1 375 2.01 2.01 11.1 346 1.84 1.84 12.0 317 1.50 1.50 13.8 258 1.67 1.67 10.0 288 1.50 1.50 10.9 258 1.33 1.33 11.8 229 1.00 1.00 13.6 172 3.13 3.06 10.8 539 2.90 2.90 11.5 498 2.70 2.70 12.4 465 2.30 2.30 14.3 396 2.49 2.49 10.5 429 2.29 2.29 11.4 395 2.09 2.09 12.4 360 1.69 1.69 14.2 291 1.89 1.89 10.4 325 1.69 1.69 11.3 290 1.49 1.49 12.2 256 1.10 1.10 14.0 189 3.52 3.46 11.1 606 3.26 3.26 11.9 561 3.03 3.03 12.8 522 2.58 2.58 14.6 444 2.79 2.79 10.9 480 2.56 2.56 11.8 441 2.33 2.33 12.7 401 1.87 1.87 14.5 322 2.09 2.09 10.7 359 1.86 1.86 11.7 320 1.63 1.63 12.5 281 1.19 1.19 14.3 205 3.91 3.84 11.3 672 3.61 3.61 12.2 620 3.35 3.35 13.1 577 2.84 2.84 14.9 489 3.08 3.08 11.2 529 2.82 2.82 12.1 485 2.56 2.56 13.0 441 2.04 2.04 14.8 352 2.28 2.28 11.0 393 2.03 2.03 11.9 349 1.77 1.77 12.8 305 1.27 1.27 14.6 218 4.28 4.22 11.6 735 3.94 3.94 12.5 678 3.66 3.66 13.4 630 3.10 3.10 15.1 533 3.35 3.35 11.4 577 3.07 3.07 12.3 528 2.78 2.78 13.2 479 2.21 2.21 15.0 380 2.47 2.47 11.3 424 2.18 2.18 12.2 376 1.90 1.90 13.1 327 1.34 1.34 14.8 231 1.13 1.13 8.4 195 1.06 1.06 9.4 182 0.98 0.98 10.3 168 0.82 0.82 12.2 141 0.91 0.91 8.3 156 0.83 0.83 9.2 142 0.75 0.75 10.2 129 0.58 0.58 12.1 100 1.92 1.76 9.8 330 1.71 1.69 10.5 295 1.61 1.61 11.1 277 1.39 1.39 13.0 240 1.51 1.51 9.1 259 1.40 1.40 10.0 241 1.29 1.29 11.0 222 1.08 1.08 12.8 185 1.19 1.19 8.9 205 1.08 1.08 9.8 186 0.97 0.97 10.8 167 0.74 0.74 12.7 128 2.33 2.21 10.2 401 2.13 2.13 10.7 366 1.99 1.99 11.6 342 1.71 1.71 13.5 295 6-11 7-12 8-13 10-15 Air flow, l/s (m3/h) 69.0 (250) 97.0 (350) Data type** Water temp. in-out* Relative humidity 50 % TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE kW kW °C l/h kW kW °C l/h kW kW °C l/h kW kW °C l/h 125.0 (450) 153.0 (550) 181.0 (650) 208.0 (750) 236.0 (850) 264.0 (950) Entering air dry bulb temperature, °C 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 1.91 1.31 9.2 328 1.72 1.23 10.2 296 1.51 1.14 11.2 260 1.20 1.19 10.6 206 1.99 1.76 10.3 343 1.61 1.60 11.4 277 1.58 1.58 11.5 271 1.58 1.58 11.5 271 1.44 1.44 9.5 248 1.30 1.30 10.4 224 1.17 1.17 11.3 201 0.88 0.88 13.2 152 3.77 2.70 10.2 649 3.32 2.51 11.2 571 2.82 2.30 12.3 485 2.35 2.35 12.1 405 2.30 2.10 10.6 396 2.01 1.99 11.2 346 1.84 1.84 12.0 317 1.84 1.84 12.0 317 1.67 1.67 10.0 288 1.50 1.50 10.9 258 1.33 1.33 11.8 229 1.00 1.00 13.6 172 4.37 3.13 10.4 751 3.82 2.90 11.5 656 3.24 2.67 12.6 558 1.20 1.19 10.6 206 2.61 2.41 10.9 448 2.29 2.29 11.4 395 2.09 2.09 12.4 360 0.98 0.98 10.3 168 1.89 1.89 10.4 325 1.69 1.69 11.3 290 1.49 1.49 12.2 256 1.10 1.10 14.0 189 4.94 3.54 10.7 849 4.33 3.29 11.7 745 3.66 3.02 12.8 629 1.61 1.61 11.1 277 2.90 2.72 11.2 500 2.56 2.56 11.8 441 2.33 2.33 12.7 401 1.29 1.29 11.0 222 2.09 2.09 10.7 359 1.86 1.86 11.7 320 1.63 1.63 12.5 281 1.19 1.19 14.3 205 5.52 3.95 10.9 949 4.81 3.66 12.0 828 4.06 3.36 13.0 699 1.99 1.99 11.6 342 3.20 3.01 11.4 551 2.82 2.82 12.1 485 2.56 2.56 13.0 441 1.58 1.58 11.5 271 2.28 2.28 11.0 393 2.03 2.03 11.9 349 1.77 1.77 12.8 305 1.27 1.27 14.6 218 6.01 4.32 11.3 1034 5.28 4.01 12.2 908 4.46 3.69 13.3 767 2.35 2.35 12.1 405 3.46 3.29 11.7 595 3.07 3.07 12.3 528 2.78 2.78 13.2 479 1.84 1.84 12.0 317 2.47 2.47 11.3 424 2.18 2.18 12.2 376 1.90 1.90 13.1 327 1.34 1.34 14.8 231 1.32 1.07 9.2 226 1.12 0.98 10.2 193 0.91 0.89 11.3 156 0.98 0.98 10.3 168 0.91 0.89 8.4 156 0.83 0.83 9.2 142 0.75 0.75 10.2 129 0.58 0.58 12.1 100 2.54 1.78 9.6 437 2.26 1.66 10.7 389 1.97 1.53 11.8 339 1.61 1.61 11.1 277 1.67 1.42 9.8 287 1.38 1.30 10.9 238 1.29 1.27 11.2 222 1.29 1.29 11.0 222 1.19 1.19 8.9 205 1.08 1.08 9.8 186 0.97 0.97 10.8 167 0.74 0.74 12.7 128 3.17 3.24 9.9 544 2.79 2.08 11.0 481 2.40 1.91 12.1 412 1.99 1.99 11.6 342 6-11 7-12 8-13 10-15 * ** Air flow, l/s (m3/h) 69.0 (250) 97.0 (350) Data type** Water temp. in-out* Relative humidity 60 % TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE TC SHC TSA DE kW kW °C l/h kW kW °C l/h kW kW °C l/h kW kW °C l/h 125.0 (450) 153.0 (550) 181.0 (650) 208.0 (750) 236.0 (850) 22 19 25 22 19 25 22 19 25 22 19 25 22 19 25 22 19 2.33 1.31 9.2 401 2.14 1.23 10.1 369 1.95 1.15 11.2 335 1.51 0.97 13.3 260 2.69 1.79 10.1 463 2.30 1.62 11.2 397 1.90 1.46 12.3 327 1.30 1.23 13.8 223 1.51 1.31 10.4 260 1.30 1.23 10.9 224 1.17 1.17 11.3 201 0.88 0.88 13.2 152 4.44 2.72 10.0 820 4.35 2.55 11.0 748 3.90 2.36 12.0 670 2.85 1.95 14.3 490 3.18 2.14 10.4 548 2.70 1.94 11.5 465 2.19 1.73 12.6 377 1.50 1.47 14.0 258 1.70 1.54 10.7 293 1.50 1.46 11.1 258 1.33 1.33 11.8 229 1.00 1.00 13.6 172 5.52 3.17 10.3 950 5.04 2.96 11.2 867 4.51 2.75 12.2 776 3.28 2.28 14.4 565 3.64 3.48 10.6 627 3.09 2.25 11.7 532 2.47 2.00 12.8 426 1.69 1.69 14.2 291 1.90 1.77 10.9 326 1.69 1.69 11.3 290 1.49 1.49 12.2 256 1.10 1.10 14.0 189 6.25 3.58 10.6 1075 5.70 3.35 11.5 980 5.10 3.11 12.5 878 3.71 2.58 14.6 638 4.14 2.81 10.8 712 3.48 2.54 11.9 599 2.76 2.25 13.0 475 1.87 1.87 14.5 322 2.04 1.96 11.3 351 1.86 1.86 11.7 320 1.63 1.63 12.5 281 1.19 1.19 14.3 205 6.87 3.95 11.0 1181 6.31 3.71 11.8 1085 5.71 3.47 12.7 982 4.13 2.87 14.8 710 4.60 3.12 11.0 790 3.86 2.82 12.1 664 3.03 2.49 13.2 522 2.04 2.04 14.8 352 2.20 2.16 11.5 379 2.03 2.03 11.9 349 1.77 1.77 12.8 305 1.27 1.27 14.6 218 7.44 4.28 11.4 1280 6.83 4.03 12.2 1174 6.18 3.77 13.0 1062 4.53 3.15 15.0 779 5.04 3.42 11.2 866 4.23 3.09 12.3 728 3.31 2.73 13.4 570 2.21 2.21 15.0 380 2.36 2.34 11.7 405 2.18 2.18 12.2 376 1.90 1.90 13.1 327 1.34 1.34 14.8 231 1.66 1.07 9.2 286 1.47 0.98 10.3 253 1.27 0.90 11.3 218 0.80 0.71 13.5 138 1.06 0.83 9.2 183 0.85 0.73 10.3 146 0.75 0.69 10.8 129 0.58 0.58 12.1 100 3.16 1.79 9.5 544 2.90 1.67 10.6 498 2.61 1.55 11.6 449 1.97 1.30 13.8 339 2.19 1.44 9.7 376 1.90 1.31 10.8 327 1.59 1.18 11.9 274 0.96 0.93 14.0 165 Water temperature, inlet-outlet, °C TC - Total cooling capacity, kW SHC - Sensible heat capacity, kW TSA - Air discharge, °C DE - Water flow, l/h 1.31 1.08 9.9 225 1.03 0.95 10.9 177 0.97 0.94 11.1 167 0.74 0.74 12.7 128 3.98 2.26 9.8 684 3.63 2.11 10.8 625 3.26 1.96 11.8 561 2.41 1.63 14.0 415 NOTES: Operating limit: air discharge temperature 12 °C, when the unit is installed where room temperature is 27 °C dry bulb and relative humidity 70 %. To convert l/h to l/s, please divide by 3600. 28 264.0 (950) Entering air dry bulb temperature, °C 25 22 19 25 22 19 25 11.2 - Heating capacities - hot water coil, kW Air flow, l/s (m3/h) 27.7 (100) 55.5 (200) Data type** Water temp. in-out* 11.2.1 - Size 1.3 - 1-row heating 60 - 55 P TSA DE 60 - 50 P TSA DE 60 - 45 P TSA DE 50 - 45 P TSA DE 50 - 40 P TSA DE 45 - 40 P TSA DE 40 - 35 P TSA DE 40 - 30 P TSA DE kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h 83.3 (300) 94.4 (340) 111.1 (400) 125.0 (450) 139.0 (500) 167.0 (600) Entering air dry bulb temperature, °C 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 1.13 52.5 198 1.02 49.3 89 0.87 44.6 50 0.83 43.6 145 0.67 39.0 58 0.67 38.7 115 0.50 33.7 86 0.38 30.3 33 2.49 40.3 435 2.25 38.0 196 1.95 35.0 113 1.86 34.1 322 1.57 31.3 136 1.54 31.0 266 1.22 27.9 211 0.78 23.6 67 2.69 39.0 469 2.45 36.6 213 2.18 34.0 126 2.05 32.8 356 1.79 30.3 155 1.73 29.7 300 1.41 26.6 244 0.97 22.4 84 2.45 40.3 427 2.19 38.1 191 1.84 35.0 107 1.77 34.4 308 1.44 31.6 125 1.43 31.5 249 1.10 28.5 190 0.63 24.5 55 2.66 38.9 464 2.39 36.6 209 2.09 34.0 121 1.98 33.0 343 1.69 30.5 146 1.64 30.1 284 1.30 27.2 224 0.82 23.1 71 2.87 37.5 500 2.60 35.2 227 2.33 32.9 135 2.18 31.6 379 1.90 29.2 165 1.84 28.7 319 1.50 25.8 260 1.03 21.8 89 2.65 38.6 463 2.36 36.5 206 2.01 33.9 117 1.92 33.2 333 1.58 30.7 137 1.55 30.5 269 1.18 27.8 205 0.67 24.0 58 2.88 37.1 502 2.58 34.9 225 2.28 32.7 132 2.14 31.7 371 1.83 29.4 159 1.77 29.0 307 1.40 26.3 242 0.88 22.4 76 3.11 35.5 542 2.81 33.4 245 2.50 31.2 145 2.36 30.1 410 2.05 27.9 178 1.99 27.4 345 1.62 24.7 280 1.11 21.1 96 2.81 37.5 489 2.49 35.4 217 2.14 33.1 124 2.03 32.3 352 1.68 30.0 145 1.64 29.8 283 1.25 27.2 216 0.70 23.6 60 3.04 35.8 531 2.72 33.7 237 2.40 31.6 139 2.26 30.7 392 1.93 28.5 167 1.87 28.2 324 1.48 25.6 255 0.92 22.0 79 3.28 34.2 572 2.96 32.1 258 2.64 30.0 153 2.50 29.1 433 2.16 26.9 187 2.10 26.5 364 1.71 24.0 296 1.18 20.6 102 2.94 36.4 513 2.61 34.4 227 2.25 32.3 131 2.12 31.6 368 1.77 29.5 153 1.71 29.1 297 1.30 26.7 226 0.72 23.3 62 3.19 34.7 557 2.85 32.7 249 2.51 30.7 145 2.37 29.9 411 2.01 27.8 175 1.96 27.5 339 1.55 25.1 267 0.96 21.6 83 3.44 33.0 600 3.10 31.0 270 2.75 29.0 160 2.62 28.2 454 2.26 26.1 196 2.20 25.8 382 1.79 23.4 309 1.24 20.2 107 3.18 34.7 555 2.81 32.9 245 2.43 31.0 141 2.29 30.3 398 1.90 28.4 165 1.78 28.6 309 1.41 25.9 243 0.77 22.8 66 3.45 32.9 602 3.08 31.0 268 2.69 29.2 156 2.56 28.5 444 2.17 26.6 188 2.04 26.9 353 1.67 24.1 288 1.03 21.1 89 3.72 31.0 649 3.34 29.2 291 2.96 27.3 172 2.83 26.7 491 2.43 24.8 211 2.29 25.1 397 1.93 22.3 334 1.35 19.5 116 1.23 52.0 215 1.13 49.1 98 0.97 44.3 56 0.93 43.2 161 0.77 38.6 67 0.77 38.5 133 0.60 33.5 103 0.46 29.6 40 1.33 51.5 232 1.23 48.8 108 1.07 44.0 62 1.02 42.7 178 0.87 38.3 76 0.87 38.2 150 0.70 33.2 121 0.55 28.9 47 1.82 46.0 318 1.65 43.5 144 1.35 39.0 78 1.33 38.6 230 1.06 34.6 92 1.08 35.0 187 0.80 30.9 139 0.52 26.7 45 1.98 45.0 345 1.81 42.5 157 1.53 38.4 89 1.48 37.7 257 1.23 34.0 107 1.23 34.0 213 0.97 30.2 168 0.65 25.5 56 2.14 44.0 373 1.96 41.5 171 1.71 37.7 99 1.63 36.7 284 1.41 33.4 122 1.38 33.1 240 1.13 29.4 196 0.79 24.5 69 2.30 41.7 401 2.06 39.3 179 1.71 35.9 99 1.66 35.4 289 1.34 32.3 117 1.35 32.3 233 1.03 29.2 178 0.60 25.0 52 60 - 55 P TSA DE 60 - 50 P TSA DE 60 - 45 P TSA DE 50 - 45 P TSA DE 50 - 40 P TSA DE 45 - 40 P TSA DE 40 - 35 P TSA DE 40 - 30 P TSA DE * ** Air flow, l/s (m3/h) 55.5 (200) 83.3 (300) Data type** Water temp. in-out* 11.2.2 - Size 2.3 - 1-row heating kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h 111.1 (400) 139.0 (500) 167.0 (600) 189.0 (680) 194.0 (700) Entering air dry bulb temperature, °C 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 2.04 49.2 356 1.89 47.0 165 1.65 43.4 96 1.50 41.2 260 1.28 38.0 111 1.23 37.2 213 0.95 33.0 164 0.63 28.3 55 3.38 40.8 589 3.09 38.6 269 2.78 36.4 161 2.53 34.5 439 2.22 32.3 193 2.11 31.4 365 1.68 28.3 291 1.18 24.7 102 3.64 39.4 636 3.35 37.3 292 3.05 35.1 177 2.79 33.2 485 2.48 31.0 215 2.36 30.1 410 1.94 27.0 335 1.50 23.8 129 3.50 39.7 610 3.16 37.7 275 2.80 35.6 163 2.55 34.1 442 2.19 32.0 190 2.07 31.3 359 1.59 28.4 275 0.99 24.9 85 3.79 38.2 662 3.45 36.2 301 3.10 34.1 180 2.84 32.6 492 2.48 30.5 215 2.36 29.8 408 1.88 27.0 325 1.34 23.8 116 4.09 36.7 713 3.75 34.7 326 3.39 32.7 197 3.13 31.1 543 2.77 29.1 240 2.65 28.4 459 2.17 25.6 375 1.70 22.8 147 3.82 37.9 667 3.44 36.0 300 3.04 34.0 176 2.78 32.7 482 2.37 30.7 206 2.26 30.1 391 1.73 27.5 300 1.08 24.3 93 4.14 36.2 723 3.76 34.4 327 3.36 32.4 195 3.09 31.1 537 2.69 29.1 233 2.57 28.6 445 2.04 26.0 354 1.47 23.2 127 4.47 34.6 779 4.08 32.7 355 3.68 30.8 213 3.41 29.5 592 3.01 27.5 261 2.89 26.9 500 2.36 24.4 408 1.87 22.0 161 4.05 36.6 706 3.63 34.8 317 3.20 32.9 186 2.94 31.8 510 2.50 29.9 217 2.39 29.4 413 1.83 27.0 317 1.14 24.0 99 4.39 34.9 765 3.97 33.1 346 3.54 31.3 205 3.27 30.1 568 2.84 28.2 246 2.72 27.7 471 2.16 25.3 374 1.57 28.0 136 4.73 33.2 825 4.31 31.4 376 3.88 29.5 225 3.61 28.4 627 3.17 26.5 275 3.05 26.0 529 2.49 23.6 431 1.99 21.5 172 4.31 37.2 752 3.87 35.4 337 3.42 33.5 198 3.13 32.2 543 2.67 30.3 231 2.18 28.2 126 1.95 27.2 336 1.46 25.2 126 4.67 35.6 815 4.23 33.7 368 3.77 31.8 219 3.48 30.6 605 3.02 28.6 262 2.54 26.6 147 2.30 25.6 397 1.81 23.6 156 5.04 33.9 878 4.59 32.0 400 4.13 30.1 240 3.84 28.9 667 3.38 27.0 293 2.90 25.0 167 2.65 24.0 458 2.16 22.0 187 2.21 48.4 386 2.06 46.2 180 1.85 43.1 107 1.67 40.4 290 1.47 37.6 128 1.40 36.4 242 1.12 32.4 194 0.80 27.7 69 2.39 47.6 417 2.24 45.4 195 2.04 42.7 119 1.84 39.7 319 1.67 37.1 144 1.57 35.7 271 1.29 31.7 223 0.98 27.2 85 2.65 45.1 462 2.42 42.9 211 2.16 40.3 125 1.93 38.1 336 1.68 35.6 146 1.58 34.6 273 1.22 31.1 211 0.77 26.6 67 2.87 44.0 501 2.64 41.8 230 2.40 39.4 139 2.15 37.0 374 1.91 34.7 166 1.80 33.5 311 1.44 30.0 249 1.01 25.8 87 Water temperature, inlet-outlet, °C TC - Total cooling capacity, kW SHC - Sensible heat capacity, kW TSA - Air discharge, °C DE - Water flow, l/h 3.10 42.9 540 2.87 40.7 250 2.62 38.4 152 2.38 36.0 413 2.13 33.6 185 2.02 32.5 349 1.66 29.0 286 1.26 25.2 109 3.12 42.1 544 2.83 39.9 246 2.52 37.7 146 2.27 35.8 394 1.97 33.5 170 1.85 32.7 320 1.43 29.6 247 0.89 25.6 77 NOTES To avoid all risk of stratification, Carrier advises to keep discharge air temperature below 35 °C. To convert l/h to l/s, please divide by 3600. ATTENTION To discharge temperature must not exceed 55 °C to avoid damage to the unit fan motor. 29 11.2 - Heating capacities - hot water coil, kW (continued) 60-55 60-50 60-45 55-50 55-45 55-40 50-45 50-40 50-35 45-40 45-35 45-30 40-35 40-30 * ** Air flow, l/s (m3/h) 69.0 (250) 97.0 (350) Data type** Water temp. in-out* 11.2.3 - Size 4.4 - 1-row heating P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h 125.0 (450) 153.0 (550) 181.0 (650) 208.0 (750) 236.0 (850) 264.0 (950) Entering air dry bult temperature, °C 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 2.71 51.1 473 2.56 49.3 223 2.38 47.2 138 2.36 47.0 411 2.20 45.1 191 1.96 42.2 113 2.01 42.8 349 1.84 40.8 159 1.51 36.9 87 1.66 38.6 287 1.43 35.9 124 1.06 31.6 61 1.30 34.4 225 0.99 30.7 86 4.34 44.3 757 4.05 42.3 352 3.73 40.3 216 3.81 40.8 662 3.51 38.8 305 3.17 36.7 184 3.28 37.3 569 2.96 35.3 257 2.59 32.8 149 2.74 33.9 475 2.42 31.7 209 1.87 28.2 108 2.21 30.4 382 1.82 27.8 157 4.68 43.1 816 4.38 41.2 382 4.07 39.2 236 4.14 39.7 721 3.84 37.8 334 3.51 35.6 203 3.61 36.3 626 3.30 34.2 286 2.95 32.0 170 3.07 32.8 532 2.75 30.7 238 2.27 27.6 131 2.54 29.3 439 2.20 27.1 190 4.49 43.2 784 4.15 41.3 361 3.77 39.3 219 3.90 40.0 678 3.54 38.1 308 3.15 35.9 182 3.30 36.8 573 2.93 34.8 254 2.47 32.3 142 2.70 33.6 468 2.32 31.5 200 1.64 27.8 95 2.10 30.3 364 1.61 27.7 139 4.87 41.9 849 4.52 40.1 394 4.15 38.1 240 4.27 38.7 743 3.91 36.8 340 3.52 34.8 204 3.67 35.6 637 3.30 33.6 286 2.89 31.4 167 3.07 32.4 532 2.69 30.3 233 2.10 27.2 121 2.47 29.2 427 2.04 26.9 177 5.25 40.7 915 4.90 38.8 427 4.52 36.9 262 4.64 37.5 808 4.29 35.6 372 3.90 33.6 226 4.04 34.3 702 3.67 32.4 319 3.27 30.2 189 3.44 31.1 596 3.06 29.1 265 2.55 26.5 147 2.84 28.0 490 2.44 25.9 211 4.92 41.4 858 4.52 39.6 394 4.10 37.7 238 4.26 38.4 742 3.86 36.6 335 3.41 34.5 197 3.61 35.4 626 3.19 33.5 276 2.70 31.3 156 2.95 32.4 511 2.51 30.5 218 1.79 27.2 103 2.29 29.5 397 1.77 27.0 153 5.33 40.0 929 4.93 38.2 429 4.51 36.3 261 4.67 37.1 812 4.26 35.2 370 3.82 33.2 221 4.01 34.1 696 3.59 32.2 311 3.13 30.1 181 3.35 31.1 581 2.92 29.2 253 2.30 26.4 133 2.69 28.1 466 2.24 26.1 193 5.74 38.6 1001 5.34 36.8 465 4.92 34.9 285 5.08 35.7 884 4.67 33.8 406 4.23 31.9 245 4.42 32.7 767 4.00 30.8 347 3.54 28.8 205 3.76 29.8 651 3.32 27.8 288 2.80 25.5 161 3.09 26.8 535 2.64 24.8 228 5.29 39.9 923 4.85 38.2 423 4.38 36.3 254 4.58 37.1 798 4.13 35.3 359 3.64 33.4 211 3.88 34.3 673 3.41 32.5 296 2.90 30.4 167 3.17 31.5 549 2.69 29.6 233 1.93 26.6 111 2.46 28.7 426 1.91 26.5 165 5.73 38.4 999 5.29 36.7 461 4.82 34.8 280 5.02 35.6 873 4.57 33.9 397 4.08 32.0 236 4.31 32.8 748 3.85 31.0 334 3.34 29.1 193 3.60 30.1 624 3.12 28.2 270 2.48 25.7 143 2.89 27.3 500 2.39 25.3 206 6.17 36.9 1077 5.73 35.2 499 5.26 33.4 305 5.46 34.1 950 5.01 32.4 435 4.53 30.5 262 4.75 31.4 824 4.28 29.6 371 3.78 27.6 219 4.03 28.6 699 3.56 26.7 308 3.01 24.7 174 3.32 28.8 574 2.82 23.9 244 5.62 38.6 981 5.14 36.9 448 4.64 35.1 269 4.87 36.0 847 4.38 34.3 381 3.85 32.4 223 4.12 33.3 715 3.61 31.6 313 3.06 29.7 177 3.36 30.7 583 2.84 28.9 246 2.05 26.2 118 2.61 28.1 451 2.03 26.1 176 6.09 37.0 1062 5.61 35.3 489 5.10 33.6 296 5.33 34.4 928 4.84 32.7 421 4.32 30.9 250 4.58 31.8 795 4.07 30.0 353 3.53 28.2 204 3.82 29.2 662 3.30 27.4 286 2.64 25.1 152 3.06 26.6 530 2.52 24.7 218 6.56 35.4 1144 6.08 33.7 529 5.57 32.0 323 5.80 32.8 1009 5.31 31.1 461 4.79 29.3 277 5.04 30.2 875 4.54 28.5 393 4.00 26.6 231 4.28 27.6 742 3.76 25.8 326 3.20 23.9 184 3.52 25.0 609 2.99 23.2 258 5.92 37.5 1033 5.41 35.9 471 4.86 34.2 282 5.13 35.0 892 4.60 33.3 400 4.04 31.6 234 4.33 32.5 753 3.79 30.8 329 3.20 29.0 185 3.54 30.0 613 2.98 28.3 258 2.17 25.8 125 2.74 27.5 474 2.15 25.7 185 6.41 35.8 1119 5.90 34.2 514 5.36 32.5 311 5.62 33.3 977 5.09 31.7 442 4.53 30.0 262 4.82 30.9 836 4.28 29.2 371 3.70 27.4 214 4.02 28.4 697 3.46 26.7 300 2.79 24.6 161 3.22 25.9 557 2.64 24.2 228 6.91 34.1 1205 6.39 32.5 557 5.85 30.9 339 6.11 31.6 1063 5.58 30.0 485 5.02 28.3 291 5.31 29.2 921 4.77 27.5 413 4.19 25.8 242 4.51 26.8 781 3.95 25.1 342 3.35 23.2 193 3.70 24.3 641 3.13 22.6 270 2.94 50.5 513 2.79 48.7 243 2.61 46.6 151 2.59 46.3 450 2.43 44.5 211 2.21 41.9 128 2.23 42.2 388 2.06 40.2 179 1.77 36.7 102 1.88 38.0 325 1.67 35.6 145 1.31 31.4 76 1.52 33.8 263 1.24 30.6 107 3.17 49.8 554 3.02 48.0 263 2.84 46.0 165 2.82 45.7 490 2.66 43.8 231 2.47 41.6 143 2.46 41.5 427 2.29 39.6 199 2.03 36.5 117 2.10 37.4 364 1.92 35.3 166 1.57 31.2 90 1.74 33.2 302 1.49 30.3 129 3.42 48.0 597 3.20 46.0 278 2.94 43.9 171 2.97 44.2 518 2.74 42.2 238 2.46 39.8 142 2.52 40.4 438 2.28 38.3 197 1.88 34.9 109 2.07 36.6 359 1.79 34.2 155 1.28 29.9 74 1.62 32.7 281 1.23 29.4 106 3.71 47.1 647 3.48 45.2 303 3.23 43.0 187 3.26 43.3 567 3.02 41.3 263 2.76 39.1 160 2.81 39.5 487 2.56 37.4 222 2.21 34.5 128 2.35 35.7 408 2.10 33.5 181 1.61 29.5 93 1.90 31.9 329 1.56 29.0 134 Water temperature, inlet-outlet, °C P - Heating capacity, kW TSA - Air discharge temperature, °C DE - Water flow, l/h 4.00 46.2 698 3.77 44.3 329 3.52 42.2 204 3.55 42.5 617 3.31 40.4 288 3.05 38.2 176 3.09 38.6 537 2.85 36.6 247 2.54 34.1 147 2.64 34.8 457 2.38 32.7 206 1.95 29.1 112 2.18 31.1 377 1.88 28.6 162 4.00 45.3 698 3.71 43.4 323 3.39 41.3 197 3.48 41.9 605 3.17 39.9 276 2.84 37.7 164 2.95 38.4 511 2.63 36.3 228 2.20 33.4 127 2.42 34.9 419 2.09 32.7 181 1.47 28.7 85 1.88 31.4 326 1.43 28.4 124 NOTES To avoid all risk of stratification, Carrier advises to keep discharge air temperature below 35 °C. To convert l/h to l/s, please divide by 3600. ATTENTION To discharge temperature must not exceed 55 °C to avoid damage to the unit fan motor. 30 11.2 - Heating capacities - hot water coil, kW (continued) 55 - 50 P TSA DE 55 - 45 P TSA DE 55 - 40 P TSA DE 50 - 45 P TSA DE 50 - 40 P TSA DE 50 - 35 P TSA DE 45 - 40 P TSA DE 45 - 35 P TSA DE 45 - 30 P TSA DE 40 - 35 P TSA DE * ** Air flow, l/s (m3/h) 27.7 (100) 55.5 (200) Data type** Water temp. in-out* 11.2.4 - Size 1.3 - 5-row changeover kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h 83.3 (300) 94.4 (340) 111.1 (400) 125.0 (450) 139.0 (500) 167.0 (600) Entering air dry bult temperature, °C 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 1.03 49.4 178 1.01 48.9 88 0.98 48.0 57 0.88 45.1 153 0.86 44.5 75 0.82 43.4 48 0.74 40.8 128 0.71 40.1 62 0.66 38.6 38 0.59 36.5 102 3.25 47.7 565 3.13 46.5 272 2.83 43.6 164 2.82 43.5 489 2.64 41.8 229 2.29 38.3 132 2.38 39.3 413 2.14 36.9 185 1.76 33.2 101 1.94 35.0 336 3.54 47.2 616 3.42 46.1 297 3.15 43.4 182 3.10 43.0 539 2.95 41.5 256 2.61 38.2 151 2.67 38.8 462 2.44 36.6 212 2.07 33.0 119 2.23 34.5 385 3.32 47.9 577 3.16 46.5 275 2.78 43.2 161 2.84 43.7 492 2.61 41.7 226 2.16 37.8 125 2.35 39.5 407 2.03 36.6 175 1.57 32.7 91 1.85 35.1 320 3.64 47.3 633 3.48 46.0 303 3.14 43.1 182 3.15 43.2 547 2.95 41.4 256 2.52 37.7 146 2.66 38.9 461 2.37 36.5 206 1.92 32.5 110 2.17 34.7 376 3.96 46.8 689 3.81 45.5 331 3.51 42.9 203 3.47 42.6 603 3.29 41.1 286 2.89 37.6 167 2.98 38.4 516 2.72 36.2 236 2.27 32.3 131 2.48 35.1 430 3.83 47.3 666 3.62 45.8 314 3.17 42.5 184 3.27 43.2 567 3.00 41.2 260 2.44 37.0 141 2.70 39.0 468 2.31 36.1 200 1.73 31.8 100 2.13 34.8 369 4.19 46.7 730 3.99 45.2 347 3.60 42.4 208 3.63 42.6 630 3.39 40.9 294 2.86 37.0 165 3.06 38.4 530 2.72 35.9 236 2.14 31.6 123 2.49 34.2 431 4.57 46.1 795 4.37 44.7 380 4.02 42.2 233 4.00 42.0 694 3.78 40.4 328 3.29 36.9 190 3.43 37.9 594 3.13 35.7 271 2.55 31.5 147 2.85 33.7 494 4.23 46.8 736 3.97 45.2 345 3.49 42.0 202 3.61 42.7 626 3.31 40.8 287 2.66 36.5 153 2.98 38.6 516 2.54 35.7 220 1.86 31.2 107 2.35 34.4 406 4.64 46.2 807 4.39 44.6 381 3.96 41.8 229 4.01 42.1 696 3.73 40.3 324 3.14 36.4 181 3.38 38.0 585 3.00 35.5 260 2.31 31.0 133 2.74 33.9 474 5.05 45.6 879 4.80 44.0 418 4.43 41.6 256 4.42 41.5 767 4.15 39.7 360 3.62 36.3 209 3.78 37.4 655 3.45 35.2 299 2.38 30.9 160 3.14 33.3 544 4.62 46.3 803 4.32 44.6 375 3.80 41.5 220 3.93 42.3 682 3.60 40.3 312 2.87 36.0 166 3.24 38.2 562 2.77 35.4 239 1.97 30.7 114 2.55 34.1 441 5.06 45.7 881 4.76 43.9 414 4.31 41.3 250 4.37 41.6 759 4.05 39.7 351 3.40 35.9 196 3.68 37.6 637 3.27 35.1 283 2.47 30.5 143 2.98 33.5 516 5.51 45.0 959 5.22 43.3 454 4.82 41.0 279 4.82 41.0 837 4.50 39.1 390 3.93 35.8 227 4.12 36.9 714 3.76 34.8 326 2.99 30.4 173 3.42 32.8 592 5.34 45.3 929 4.95 43.4 430 4.37 40.6 253 4.54 41.4 788 4.11 39.3 357 3.28 35.2 189 3.74 37.4 647 3.19 34.7 276 2.19 29.8 126 2.93 33.4 506 5.86 44.6 1019 5.47 42.7 475 4.97 40.3 288 5.05 40.7 877 4.63 38.6 402 3.90 35.1 225 4.24 36.7 735 3.77 34.4 326 2.79 29.6 161 3.43 32.8 593 6.38 43.8 1110 5.99 42.0 521 5.52 39.7 319 5.57 39.9 967 5.16 37.9 447 4.52 34.9 261 4.75 36.0 824 4.31 33.8 373 3.41 29.5 196 3.94 32.0 681 1.12 48.9 195 1.11 48.5 96 1.08 47.6 62 0.98 44.6 170 0.96 44.1 83 0.93 43.1 53 0.83 40.4 144 0.81 39.7 70 0.77 38.5 44 0.68 36.1 118 1.22 48.4 213 1.21 48.1 105 1.18 47.2 68 1.08 44.2 187 1.06 43.7 92 1.03 42.8 59 0.93 39.9 161 0.91 39.3 78 0.87 38.2 50 0.78 35.6 135 2.03 49.0 353 1.95 47.8 169 1.79 45.4 103 1.74 44.7 302 1.63 43.1 141 1.45 40.5 84 1.44 40.4 250 1.30 38.3 113 1.12 65.0 36 1.14 35.9 197 2.22 48.5 386 2.15 47.5 187 2.00 45.2 115 1.93 44.3 335 1.83 42.8 159 1.66 40.3 96 1.64 40.0 283 1.50 38.0 130 1.33 76.0 35 1.33 35.5 230 Water temperature, inlet-outlet, °C P - Heating capacity, kW TSA - Air discharge temperature, °C DE - Water flow, l/h 2.42 48.0 421 2.35 47.1 205 2.21 45.0 128 2.12 43.8 369 2.03 42.5 176 1.87 40.1 108 1.83 39.5 317 1.71 37.8 148 1.53 88.0 35 1.53 35.1 264 2.96 48.3 516 2.83 46.9 246 2.51 43.7 145 2.54 44.0 440 2.34 42.1 203 1.97 38.4 114 2.11 39.8 365 1.83 37.0 158 1.45 33.3 84 1.66 35.3 286 NOTES To avoid all risk of stratification, Carrier advises to keep discharge air temperature below 35 °C. To convert l/h to l/s, please divide by 3600. ATTENTION To discharge temperature must not exceed 55 °C to avoid damage to the unit fan motor. 31 11.2 - Heating capacities - hot water coil, kW (continued) 55 - 50 P TSA DE 55 - 45 P TSA DE 55 - 40 P TSA DE 50 - 45 P TSA DE 50 - 40 P TSA DE 50 - 35 P TSA DE 45 - 40 P TSA DE 45 - 35 P TSA DE 45 - 30 P TSA DE 40 - 35 P TSA DE * ** Air flow, l/s (m3/h) 55.5 (200) 83.3 (300) Data type** Water temp. in-out* 11.2.5 - Size 2.3 - 5-row changeover kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h 111.1 (400) 139.0 (500) 167.0 (600) 189.0 (680) 194.0 (700) Entering air dry bult temperature, °C 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 2.10 50.2 366 2.04 49.2 177 1.91 47.3 110 1.80 45.7 313 1.71 44.4 149 1.58 42.4 91 1.50 41.2 260 1.39 39.6 121 1.25 37.5 72 1.19 36.6 206 4.48 48.8 779 4.30 47.5 374 3.87 44.3 224 3.88 44.4 674 3.63 42.6 315 3.12 38.8 180 3.29 40.1 569 2.92 37.4 253 2.39 33.5 138 2.67 35.6 462 4.87 48.3 848 4.72 47.2 410 4.32 44.3 250 4.28 44.0 742 4.05 42.4 351 3.56 38.8 206 3.67 39.6 637 3.35 37.3 290 2.81 33.4 162 3.07 35.3 531 4.99 48.6 869 4.74 47.1 412 4.13 43.4 239 4.27 44.3 741 3.90 42.1 338 3.16 37.7 183 3.53 39.9 612 3.00 36.8 260 2.26 32.4 130 2.78 35.5 481 5.47 48.1 952 5.23 46.7 455 4.68 43.4 271 4.74 43.8 823 4.42 41.9 383 3.71 37.8 215 4.00 39.5 694 3.54 36.7 306 2.78 32.3 160 3.26 35.1 564 5.96 47.6 1038 5.73 46.2 498 5.24 43.4 303 5.22 43.3 907 4.94 41.7 428 4.27 37.8 247 4.48 39.0 776 4.07 36.6 352 3.31 32.2 191 3.73 34.7 646 5.85 47.9 1017 5.51 46.2 479 4.79 42.7 278 4.99 43.6 866 4.56 41.5 395 3.62 36.9 209 4.12 39.3 714 3.49 36.2 302 2.52 31.4 145 3.25 35.0 562 6.41 47.3 1116 6.08 45.7 528 5.45 42.6 316 5.54 43.1 962 5.17 41.2 448 4.29 36.9 248 4.67 38.8 810 4.12 36.1 357 3.13 31.3 181 3.80 34.5 657 6.98 46.8 1215 6.66 45.2 578 6.11 42.5 353 6.11 42.5 1061 5.75 40.8 499 4.96 37.0 286 5.23 38.3 907 4.75 36.0 411 3.77 31.2 218 4.35 34.0 753 6.49 47.3 1130 6.08 45.5 529 5.31 42.1 307 5.53 43.1 960 5.06 41.0 439 3.97 36.3 229 4.56 38.9 791 3.86 35.8 334 2.70 30.8 156 3.59 34.6 621 7.12 46.7 1239 6.71 44.9 583 6.04 42.0 350 6.15 42.5 1068 5.71 40.6 495 4.73 36.4 273 5.18 38.3 897 4.57 35.7 396 3.40 30.7 196 4.20 34.1 726 7.76 46.1 1350 7.35 44.4 639 6.77 41.9 392 6.78 41.9 1177 6.34 40.1 550 5.48 36.4 317 5.80 37.7 1005 5.27 35.5 456 4.13 30.6 238 4.82 33.5 833 6.65 47.1 1157 6.22 45.3 541 5.43 42.0 314 5.66 42.9 983 5.18 40.9 449 4.06 36.2 234 4.67 38.8 809 3.95 35.7 342 2.75 30.6 159 3.67 34.5 635 7.29 46.5 1269 6.87 44.7 597 6.19 41.9 358 6.30 42.4 1093 5.84 40.4 506 4.83 36.2 279 5.30 38.2 918 4.68 35.6 405 3.47 30.5 200 4.30 34.0 743 7.94 45.9 382 7.52 44.2 654 6.93 41.7 401 6.94 41.8 1205 6.49 39.9 563 5.61 36.2 324 5.94 37.6 1029 5.40 35.4 467 4.22 30.5 243 4.93 33.4 852 2.31 49.8 401 2.24 48.9 195 2.12 47.1 123 2.00 45.4 348 1.92 44.1 167 1.79 42.2 103 1.70 40.9 294 1.60 39.4 138 1.46 37.4 84 1.39 36.4 240 2.51 49.4 437 2.45 48.6 213 2.34 46.9 135 2.21 45.0 383 2.13 43.9 185 2.00 42.0 115 1.90 40.5 329 1.80 39.1 156 1.67 37.3 96 1.59 36.0 275 3.12 49.8 543 2.98 48.4 259 2.69 45.6 156 2.68 45.4 465 2.48 43.5 215 2.16 40.3 125 2.22 40.9 384 1.96 38.4 170 1.66 35.4 96 1.74 36.2 302 3.42 49.4 595 3.30 48.2 287 3.02 45.5 175 2.97 45.0 516 2.79 43.3 242 2.48 40.2 143 2.51 40.6 436 2.28 38.2 197 1.97 35.2 113 2.04 36.0 353 Water temperature, inlet-outlet, °C P - Heating capacity, kW TSA - Air discharge temperature, °C DE - Water flow, l/h 3.72 49.0 648 3.61 47.9 314 3.35 45.4 194 3.27 44.6 568 3.11 43.1 270 2.81 40.1 162 2.82 40.2 488 2.60 38.1 225 2.28 35.0 131 2.34 35.7 406 4.08 49.2 711 3.89 47.8 338 3.42 44.4 198 3.50 44.9 607 3.21 42.7 278 2.68 38.8 155 2.90 40.5 503 2.49 37.5 216 1.99 33.7 114 2.27 35.8 393 NOTES To avoid all risk of stratification, Carrier advises to keep discharge air temperature below 35 °C. To convert l/h to l/s, please divide by 3600. ATTENTION To discharge temperature must not exceed 55 °C to avoid damage to the unit fan motor. 32 11.2 - Heating capacities - hot water coil, kW (continued) 60-55 60-50 60-45 55-50 55-45 55-40 50-45 50-40 50-35 45-40 45-35 45-30 40-35 40-30 * ** Air flow, l/s (m3/h) 69.0 (250) 97.0 (350) Data type** Water temp. in-out* 11.2.6 - Size 4.4 - 5-row changeover P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE P TSA DE kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h kW °C l/h 125.0 (450) 153.0 (550) 181.0 (650) 208.0 (750) 236.0 (850) 264.0 (950) Entering air dry bult temperature, °C 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 19 16 13 3.03 54.9 529 2.99 54.5 261 2.88 53.2 167 2.63 50.2 458 2.59 49.6 225 2.46 48.2 143 2.27 45.8 393 2.19 45.0 190 2.04 43.2 118 1.89 41.4 328 1.79 40.2 155 1.62 38.2 93 1.51 36.9 262 1.38 35.3 119 5.79 53.7 1011 5.67 52.9 494 5.42 51.3 315 5.09 49.2 886 4.97 48.4 432 4.65 46.3 269 4.43 44.8 768 4.25 43.7 369 3.83 41.0 221 3.76 40.5 651 3.50 38.8 303 2.99 35.5 173 3.08 36.1 533 2.68 33.5 232 6.25 53.3 1091 6.13 52.5 534 5.91 51.1 343 5.55 48.7 965 5.43 48.0 472 5.14 46.2 298 4.87 44.4 846 4.72 43.4 409 4.33 40.9 250 4.20 40.0 727 3.97 38.6 344 3.50 35.5 202 3.52 35.7 608 3.16 33.4 274 6.42 53.6 1120 6.22 52.5 542 5.89 50.7 342 5.60 49.1 974 5.40 48.1 469 4.95 45.7 287 4.80 44.8 832 4.54 43.4 393 3.92 40.1 227 3.99 40.5 691 3.60 38.4 312 2.87 34.5 166 3.17 36.1 549 2.57 32.8 222 6.96 53.1 1215 6.77 52.1 590 6.47 50.5 376 6.13 48.7 1067 5.94 47.7 516 5.55 45.6 321 5.32 44.4 924 5.10 43.2 442 4.54 40.2 262 4.51 40.0 781 4.18 38.3 362 3.49 34.6 201 3.69 35.7 639 3.16 32.8 273 7.52 52.6 1312 7.32 51.6 638 7.05 50.2 409 6.68 48.2 1162 6.49 47.2 564 6.15 45.4 356 5.86 43.9 1018 5.65 42.8 490 5.15 40.2 298 5.04 39.6 873 4.75 38.1 411 4.11 34.7 237 4.22 35.2 730 3.75 32.8 324 7.45 52.9 1299 7.17 51.7 625 6.79 49.9 394 6.50 48.6 1132 6.23 47.4 541 5.71 45.0 331 5.56 44.3 966 5.25 42.9 455 4.49 39.5 260 4.62 40.0 800 4.15 37.9 360 3.23 33.7 186 3.67 35.7 634 2.92 32.3 252 8.08 52.4 1409 7.80 51.2 680 7.44 49.5 431 7.13 48.1 1240 6.86 46.9 596 6.41 44.9 371 6.18 43.9 1073 5.88 42.5 510 5.22 39.5 301 5.23 39.6 906 4.83 37.8 418 3.96 33.9 228 4.27 35.3 739 3.62 32.3 313 8.72 51.9 1521 8.45 50.7 736 8.09 49.1 469 7.76 47.6 1350 7.49 46.4 651 7.10 44.7 411 6.80 43.4 1181 6.51 42.1 565 5.94 39.5 343 5.84 39.1 1013 5.50 37.5 476 4.70 34.0 271 4.88 34.8 844 4.32 32.3 373 8.42 52.2 1469 8.06 50.8 702 7.59 49.0 441 7.37 48.1 1282 7.01 46.7 609 6.43 44.4 372 6.29 43.8 1093 5.90 42.3 512 5.04 38.9 291 5.22 39.6 904 4.68 37.5 405 3.56 33.1 205 4.13 35.3 715 3.25 31.8 281 9.13 51.7 1593 8.78 50.3 765 8.32 48.5 483 8.07 47.5 1405 7.72 46.2 671 7.22 44.2 418 6.99 43.3 1214 6.61 41.8 573 5.87 38.9 339 5.91 39.1 1023 5.45 37.3 472 4.41 33.2 254 4.82 34.8 833 4.06 31.9 351 9.86 51.1 1720 9.50 49.7 828 9.06 48.0 525 8.79 47.0 1530 8.44 45.6 734 7.98 43.9 462 7.70 42.8 1337 7.32 41.3 635 6.68 38.8 386 6.61 38.5 1145 6.19 36.9 536 5.26 33.3 303 5.51 34.3 953 4.85 31.8 419 9.34 51.5 1629 8.90 50.0 775 8.34 48.1 484 8.19 47.5 1424 7.75 46.0 673 7.12 43.8 412 6.99 43.3 1213 6.50 41.7 564 5.56 38.4 321 5.78 39.1 1002 5.18 37.1 449 3.88 32.5 224 4.37 34.9 791 3.57 31.4 309 10.13 50.9 1767 9.69 49.4 844 9.15 47.5 531 8.97 46.9 1561 8.54 45.4 742 7.97 43.5 461 7.76 42.8 1348 7.29 41.1 632 6.49 38.4 375 6.55 38.6 1135 6.03 36.8 522 4.85 32.7 279 5.33 34.4 922 4.48 31.4 387 10.94 50.3 1908 10.50 48.8 915 9.96 47.0 578 9.77 46.3 1700 9.34 44.9 812 8.79 43.0 509 8.55 42.2 1485 8.09 40.6 702 7.39 38.2 427 7.33 38.0 1270 6.82 36.3 591 5.80 32.8 334 6.10 33.8 1056 5.36 31.3 463 10.22 50.8 1782 9.69 49.2 844 9.05 47.2 525 8.97 46.9 1560 8.44 45.3 734 7.76 43.2 449 7.65 42.8 1327 7.08 41.1 614 6.06 37.9 350 6.32 38.7 1095 5.66 36.7 490 4.19 32.1 242 4.99 34.5 862 3.88 31.1 335 11.08 50.2 1933 10.56 48.6 920 9.92 46.6 576 9.83 46.3 1710 9.31 44.7 809 8.65 42.7 500 8.50 42.2 1475 7.94 40.5 689 7.08 37.8 409 7.16 38.1 1241 6.55 36.2 567 5.26 32.2 303 5.82 34.0 1007 4.88 31.0 422 11.96 49.5 2086 11.44 47.9 996 10.81 46.0 627 10.70 45.7 1862 10.19 44.1 885 9.54 42.1 552 9.36 41.6 1625 8.81 39.9 764 8.07 37.6 466 8.02 37.5 1389 7.42 35.7 642 6.32 32.3 364 6.67 33.4 1154 5.85 30.9 505 3.29 54.6 574 3.26 54.2 284 3.15 53.0 183 2.88 49.8 502 2.84 49.3 247 2.73 48.0 158 2.51 45.5 436 2.45 44.7 212 2.31 43.1 133 2.14 41.0 370 2.05 40.0 177 1.89 38.1 109 1.76 36.6 304 1.64 35.2 141 3.55 54.2 620 3.52 53.8 307 3.43 52.8 199 3.14 49.4 546 3.10 49.0 270 3.00 47.8 174 2.76 45.1 480 2.71 44.4 235 2.58 42.9 149 2.39 40.7 413 2.31 39.7 200 2.15 38.0 124 2.00 36.2 346 1.90 35.0 164 4.21 54.6 734 4.14 54.0 360 3.93 52.3 228 3.66 50.0 637 3.57 49.2 310 3.33 47.2 193 3.14 45.6 546 3.01 44.4 261 2.71 41.9 156 2.62 41.2 455 2.42 39.5 210 2.08 36.6 120 2.09 36.7 361 1.81 34.3 156 4.57 54.2 797 4.50 53.7 392 4.31 52.1 250 4.01 49.6 698 3.93 48.9 341 3.71 47.1 215 3.49 45.2 605 3.37 44.2 292 3.09 41.9 179 2.96 40.8 514 2.79 39.3 241 2.46 36.6 142 2.43 36.3 420 2.18 34.2 188 Water temperature, inlet-outlet, °C P - Heating capacity, kW TSA - Air discharge temperature, °C DE - Water flow, l/h 4.93 53.8 860 4.86 53.3 424 4.70 51.9 273 4.36 49.2 759 4.29 48.6 373 4.09 46.9 237 3.84 44.8 666 3.73 43.9 324 3.48 41.8 201 3.31 40.4 574 3.15 39.1 273 2.85 36.6 164 2.78 36.0 480 2.55 34.1 220 5.34 54.1 932 5.21 53.3 454 4.93 51.5 286 4.65 49.6 809 4.52 48.7 392 4.16 46.4 241 3.99 45.2 693 3.79 43.9 328 3.33 40.9 192 3.32 40.5 576 3.02 38.9 262 2.49 35.4 144 2.64 36.4 457 2.20 33.5 190 NOTES To avoid all risk of stratification, Carrier advises to keep discharge air temperature below 35 °C. To convert l/h to l/s, please divide by 3600. ATTENTION To discharge temperature must not exceed 55 °C to avoid damage to the unit fan motor. 33 11.3 - Coil pressure drop Pressure drop (kPa) Water flow, (l/h) 11.3.1 - Water pressure drop curves, ICM size 1.3 Cooling Heating Pressure drop (kPa) Water flow, (l/h) 11.3.2 - Water pressure drop curves, ICM size 2.3 Cooling Heating Pressure drop (kPa) NOTES : The curves are plotted for the following conditions : - entering hot water temperature 50°C - entering chiled water temperature 6°C To convert l/h to l/s, please divide by 3600. 34 11.3 - Coil pressure drop, continued Water flow, (l/h) 11.3.3 - Water pressure drop curves, ICM size 4.4 5 rows 1 row Pressure drop (kPa) NOTES : The curves are plotted for the following conditions : - entering hot water temperature 50°C - entering chiled water temperature 6°C To convert l/h to l/s, please divide by 3600. 35 11.4 - Valve pressure drops Water flow, (l/h) Water pressure drop across the 2-way valve s Kv low .F :1 A- AB Pressure drop (kPa) Water flow, (l/h) Water pressure drop across the 3-way valve s: Kv s Kv 1. w Flo A- AB B ss pa By . .63 :0 B -A Pressure drop (kPa) NOTE To convert l/h to l/s, please divide by 3600. 36 11.5 - Electrical coil performenco 11.5.1 - ICM sizes 1.3 and 2.3 W 5 elements 4 elements Capacity, W 3 elements 2 elements 1 element l/s Flow volume, Qv NOTE Data obtained with an entering air temperatur of 19 °C Supply voltage : 230 V 37 11.5 - Electrical coil performance (continued) 11.5.2 - ICM size 4.4 W 5 elements Capacity, W 4 elements 3 elements 2 elements 1 element l/s Flow volume, Qv NOTE Data obtained with an entering air temperatur of 19 °C Supply voltage : 230 V 38 11.6 - Sound power level 11.6.1 - ICM size 1.3 11.6.2 - ICM size 2.3 Octave band frequency, Hz U (V) 230 200 180 150 120 Octave band frequency, Hz 125 250 500 1K 2K dBA SOU 188.8-680-120 REP RAD 66.7 55.3 57.8 62.6 49.2 46.8 63.1 46.8 42.6 67.2 39.3 40.9 60.7 29.1 31.5 68.9 47.1 46.5 SOU 230 130.45-470-330 REP RAD 71.8 59.6 59.8 66.7 52.7 53.1 64.9 48.8 44.9 67.3 39.3 41.4 62.9 27.1 33.9 70.0 49.7 49.2 U (V) Qv-P Type (l/s-m3/h-Pa) Qv-P Type (l/s-m3/h-Pa) 125 250 500 1K 2K dBA SOU 155.5-560-30 REP RAD 72.0 64.3 61.1 68.2 60.3 55.1 67.8 53.6 45.5 67.2 51.8 40.7 64.0 38.0 33.3 70.9 56.8 49.9 SOU 145.8-525-120 REP RAD 64.4 56.8 58.3 62.2 55.6 50.3 63.4 50.8 42.9 65.8 50.5 39.9 62.1 36.6 32.6 68.4 53.6 47.3 SOU 136.9-493-161 REP RAD 66.7 61.1 57.7 62.5 57.4 51.6 63.5 51.5 45.3 66.1 51.5 43.0 62.5 36.5 37.3 68.7 55.0 48.9 72.2-260-479 SOU REP RAD 76.7 63.9 63.0 71.4 55.8 56.7 68.5 51.4 48.0 68.7 40.9 43.3 64.3 29.2 35.3 72.4 52.8 52.2 SOU 125.0-450-50 REP RAD 61.9 53.1 60.3 58.4 51.1 49.5 60.7 47.5 42.5 62.3 46.4 36.2 58.1 32.1 29.0 64.9 49.7 47.1 158.3-570-91 SOU REP RAD 61.7 53.5 59.9 58.0 44.6 46.4 58.6 42.4 40.1 62.2 35.7 38.5 54.4 23.6 26.0 63.8 43.3 46.2 SOU 123.3-444-90 REP RAD 61.0 58.8 58.0 58.5 52.5 47.2 60.8 48.5 42.5 62.5 47.3 40.1 57.8 33.3 32.8 65.0 50.6 46.4 SOU 122.2-440-252 REP RAD 69.2 57.6 58.3 64.1 49.2 50.6 62.3 45.5 42.4 65.8 36.8 39.5 58.3 23.6 30.1 67.8 46.8 46.9 SOU 120.8-435-113 REP RAD 64.3 58.7 56.6 59.8 55.4 50.4 61.8 50.5 43.9 63.8 49.3 41.4 58.9 34.6 34.6 66.2 53.1 47.4 69.4-250-419 SOU REP RAD 75.1 62.6 61.7 70.0 54.5 54.9 67.2 50.4 46.4 67.5 40.1 42.0 64.1 27.5 34.1 71.4 51.6 50.6 SOU 113.9-410-30 REP RAD 57.8 51.6 58.8 54.1 49.0 48.1 57.7 47.1 40.7 58.9 45.4 34.4 54.8 29.8 26.6 61.7 48.7 45.6 125.0-450-57 SOU REP RAD 56.8 52.4 57.2 53.3 40.1 41.3 54.4 37.8 35.9 58.6 32.3 34.6 48.3 15.6 * 59.8 40.1 42.9 SOU 108.3-390-60 REP RAD 58.2 51.6 58.5 55.8 49.6 45.4 58.6 47.4 40.6 59.5 45.4 37.5 54.6 30.2 29.7 62.1 48.9 45.1 SOU 102.7-370-178 REP RAD 65.4 55.9 56.5 59.6 44.7 46.6 58.3 42.1 38.6 61.2 33.7 36.1 53.2 19.0 24.8 63.3 43.7 44.0 SOU 102.8-370-110 REP RAD 61.7 56.5 56.9 57.6 52.9 46.5 60.4 49.4 41.5 61.4 47.0 38.1 56.3 32.3 31.3 63.9 51.1 45.3 61.1-220-346 SOU REP RAD 72.7 60.7 59.4 67.2 52.1 52.6 64.4 48.2 44.3 65.9 38.5 40.1 58.6 23.5 30.6 68.7 49.6 48.4 50.4 47.9 60.2 48.6 44.2 40.4 53.4 45.6 35.4 51.4 39.1 27.4 47.9 22.6 * 55.3 44.7 44.5 94.4-340-35 73.6-265-50 SOU REP RAD SOU REP RAD 52.3 52.2 55.3 47.7 35.9 36.3 51.2 34.1 32.8 48.9 26.2 29.1 40.6 * * 52.2 38.0 40.2 53.8 48.3 58.4 51.8 45.2 41.4 55.7 46.7 38.3 54.0 39.7 31.8 48.8 24.8 23.8 57.5 45.6 43.8 75.0-270-115 88.9-320-15 SOU REP RAD SOU REP RAD 59.6 53.2 57.5 53.1 39.2 40.2 52.8 37.6 33.8 54.8 30.0 33.2 45.0 * * 56.8 40.0 42.5 56.7 51.8 57.7 53.2 48.4 43.7 56.9 48.8 38.3 55.4 42.6 32.9 50.3 27.5 24.1 58.8 48.3 43.6 48.6-175-239 86.1-310-39 SOU REP RAD SOU REP RAD 67.6 56.3 60.6 61.3 45.9 48.6 59.4 42.2 40.3 59.8 33.1 37.1 52.4 17.6 25.4 62.9 44.1 46.9 47.5 45.4 57.7 46.7 41.0 40.1 49.9 40.0 36.1 45.9 32.9 23.4 41.1 * * 50.4 39.8 42.1 66.6-240-17 83.3-300-62 SOU REP RAD SOU REP RAD 47.4 45.6 * 42.3 30.0 * 46.2 30.1 * 41.2 18.2 * 30.5 * * 45.8 35.2 * 48.8 45.9 56.9 47.8 42.5 41.4 50.9 41.9 33.4 46.7 33.6 25.5 41.9 * * 51.3 40.9 41.8 54.1-195-50 66.7-240-10 SOU REP RAD SOU REP RAD 52.0 50.4 50.6 46.2 32.5 38.6 47.5 32.5 28.4 44.8 20.7 31.9 35.1 * * 48.5 35.9 37.6 51.4 47.9 56.1 48.7 45.0 39.1 52.4 45.3 37.1 48.2 35.9 27.2 43.2 20.9 * 52.7 44.2 41.3 34.7-125-121 59.7-215-35 SOU REP RAD SOU REP RAD 58.5 51.5 56.6 52.6 38.5 40.7 51.7 35.9 34.0 50.2 26.5 32.6 41.0 * * 53.7 38.3 41.8 200 170 140 110 Legend : U Qv-P SOU REP RAD - Fan motor power Air flow/available static pressure Supply (dB re = 10-12 W) Return (dB re = 10-12 W) Radiated (dB re = 10-12 W) * Value too low for conversion to sound power level. In the case of ICMs fitted with electric heaters (in suction side), the values are identical for the same air flow. Frequency (Hz) 125 250 500 1k 2k A Correction +2 +2 +1 0 + 0,5 + 05 Measurements are based on the usual ISO standards. Any calculation of sound pressure level within a room must take account of the sound deadening effect (absorption) in the duct, plenum, room and ceiling. 39 11.6 - Sound power level (continued) 11.6.3 -ICM size 4.4 Octave band frequency, Hz U (V) Qv-P Type (l/s-m3/h-Pa) 125 250 500 1K 2K dBA Legend : SOU REP RAD 67.5 59.2 64.8 7.6 51.5 46.1 58.4 41.7 38.6 56.0 36.3 32.0 52.3 27.1 22.8 60.7 47.1 49.3 SOU 184.7-665-180 REP RAD 67.7 61.6 63.0 58.1 51.7 47.0 57.6 40.4 38.4 54.8 35.4 32.6 49.8 23.1 23.7 59.7 48.1 47.9 U Qv-P SOU REP RAD SOU 111.1-400-205 REP RAD 68.0 61.6 64.5 58.5 53.3 49.7 58.4 40.4 38.2 53.9 33.9 31.8 49.2 22.0 26.2 59.7 48.5 49.2 SOU 238.8-860-85 REP RAD 66.0 57.0 60.1 56.2 49.0 43.5 57.5 40.9 36.0 54.8 34.5 30.6 51.1 24.8 16.8 59.5 45.1 45.0 SOU 175.0-630-151 REP RAD 66.3 59.9 61.3 57.2 49.7 44.8 57.1 39.3 36.3 53.9 34.0 31.2 49.1 21.3 - 58.9 46.4 46.0 SOU 105.5-380-195 REP RAD 66.4 60.8 61.9 58.0 52.2 48.4 58.2 39.5 37.2 53.5 33.2 30.4 48.8 20.9 - 59.2 47.5 46.6 SOU 216.6-780-61 REP RAD 62.3 54.0 57.1 53.0 46.2 40.5 55.4 38.7 34.4 51.5 32.6 29.9 48.2 20.4 - 56.7 42.4 41.9 SOU 155.5-560-139 REP RAD 65.0 58.7 57.1 55.9 48.5 43.1 56.0 38.5 34.1 52.4 33.2 30.7 47.5 19.6 - 57.6 45.2 42.5 97.2-350-185 SOU REP RAD 65.8 60.5 58.6 57.6 51.6 48.4 57.6 39.3 34.5 52.6 32.4 29.3 48.1 20.3 - 58.5 47.1 44.7 177.7-640-42 SOU REP RAD 57.8 48.5 54.1 48.5 40.5 36.7 51.9 34.1 31.0 46.9 26.1 24.0 43.2 - 52.4 37.2 38.9 SOU 134.7-485-109 REP RAD 61.5 55.1 54.6 53.1 45.3 40.3 54.0 36.0 33.1 48.9 30.0 25.7 44.2 - 54.7 41.9 39.8 80.5-290-167 SOU REP RAD 63.7 58.9 54.4 56.2 49.5 46.8 56.5 37.6 32.7 51.1 30.7 26.6 46.4 17.8 - 57.1 45.3 41.5 120.8-435-22 SOU REP RAD 49.4 41.3 47.9 42.3 34.3 31.2 45.1 27.9 28.0 40.2 22.4 - 33.6 - 45.2 30.7 33.0 102.7-370-66 SOU REP RAD 54.9 48.4 48.8 47.0 39.1 34.4 48.8 30.5 29.9 42.7 23.7 23.6 36.7 - 48.8 35.6 34.7 66.6-240-126 SOU REP RAD 59.7 54.9 48.8 52.6 45.1 41.7 53.2 33.9 30.5 47.4 27.3 26.2 42.0 - 53.5 41.2 36.9 69.4-250-11 SOU REP RAD 37.0 32.8 - 35.1 27.0 - 37.3 22.6 - 29.4 - 17.0 - 35.9 23.1 26.5 58.3-210-29 SOU REP RAD 43.4 39.8 43.8 38.0 29.4 335.1 39.5 23.0 30.9 32.0 15.4 - 22.6 - 38.6 26.8 32.1 25.0-90-87 SOU REP RAD 50.5 45.6 47.0 43.7 35.5 36.5 44.5 24.9 29.0 38.6 19.4 - 29.5 - 44.3 31.8 33.5 266.6-960-80 230 200 170 140 110 80 40 - Fan motor power Air flow/available static pressure Supply (dB re = 10-12 W) Return (dB re = 10-12 W) Radiated (dB re = 10-12 W) * Value too low for conversion to sound power level. In the case of ICMs fitted with electric heaters (in suction side), the values are identical for the same air flow. Frequency (Hz) 125 250 500 1k 2k A Correction +2 +2 +1 0 + 0,5 + 05 Measurements are based on the usual ISO standards. Any calculation of sound pressure level within a room must take account of the sound deadening effect (absorption) in the duct, plenum, room and ceiling. 11.7 - Electrical data 11.7.1 - ICM size 1.3 with electrical heater, and 5-row coil 11.7.3 - ICM size 4.4 without electrical heater, and 5-row cooling coil U (V) I (A) P (W) r/s Qv m3/h Qv l/s Pressure Pa U (V) I (A) P (W) r/s Qv m3/h Qv l/s Pressure Pa 230 230 230 230 0.95 0.94 0.93 0.89 217 216 214 202 32 33 35 37 561 544 517 515 156 151 144 143 30 50 101 140 200 200 200 0.86 0.84 0.80 170 169 160 29 31 35 450 444 408 125 123 113 50 90 150 170 170 170 0.77 0.74 0.72 129 125 123 24 29 31 369 365 335 103 101 93 30 81 125 230 230 230 230 230 230 230 230 230 0.85 0.82 0.80 0.77 0.74 0.71 0.68 0.65 0.61 189 183 176 171 162 154 144 131 126 21 21 21 22 22 22 23 23 24 1012 961 898 837 752 645 522 400 188 281 267 249 233 209 179 145 111 52 59 78 100 119 141 166 190 205 229 140 140 140 0.63 0.63 0.61 88 87 85 21 25 28 299 254 224 83 71 62 31 81 130 110 110 110 0.50 0.50 0.50 55 54 55 17 19 22 204 175 150 57 49 42 26 50 75 80 80 0.37 0.37 29 29 14 17 111 69 31 19 25 51 200 200 200 200 200 200 200 200 200 0.82 0.78 0.75 0.72 0.69 0.65 0.60 0.53 0.50 164 155 149 142 135 128 117 101 95 19 20 20 21 21 22 22 23 24 988 911 859 784 718 629 491 258 100 274 253 239 218 199 175 136 72 28 31 65 85 112 131 153 180 210 230 170 170 170 170 170 170 170 170 0.73 0.70 0.67 0.64 0.58 0.51 0.46 0.44 124 119 114 108 99 86 77 75 18 19 19 20 21 22 23 23 783 732 687 627 518 349 197 98 217 203 191 174 144 97 55 27 62 84 101 120 149 185 206 219 140 140 140 140 140 140 140 0.66 0.62 0.57 0.51 0.45 0.42 0.40 92 86 79 71 64 59 57 16 18 19 21 21 22 22 608 541 464 354 226 124 39 169 150 129 98 63 34 11 59 91 120 153 180 199 210 110 110 110 110 110 0.56 0.50 0.45 0.41 0.39 60 55 49 46 43 14 17 19 20 21 387 307 203 121 19 108 85 56 34 5 57 103 139 161 185 80 80 80 80 0.44 0.43 0.41 0.38 34 34 32 30 11 13 14 16 215 210 135 24 60 58 37 7 31 33 72 108 11.7.2 - ICM size 2.3 without electrical heater, and 5 + 1 row coil U (V) I (A) P (W) r/s Qv m3/h Qv l/s Pressure Pa 230 230 230 230 230 230 230 230 230 1.04 0.98 0.92 0.86 0.82 0.78 0.73 0.70 0.67 240 223 207 193 180 171 156 146 135 32 36 38 40 41 42 43 44 45 682 615 551 480 404 344 265 206 134 189 171 153 133 112 96 74 57 37 120 194 258 320 390 438 475 490 499 200 200 200 200 200 200 200 200 0.96 0.92 0.86 0.80 0.76 0.71 0.66 0.63 194 185 172 158 148 137 124 116 29 32 35 38 40 41 43 44 570 527 461 388 321 253 184 115 158 146 128 108 89 70 51 32 91 162 234 297 354 416 460 472 170 170 170 170 170 170 170 0.86 0.82 0.78 0.73 0.68 0.64 0.60 148 140 132 124 115 106 98 24 28 32 35 38 40 41 449 410 350 285 225 173 94 125 114 97 79 63 48 26 57 128 200 271 340 384 426 140 140 140 140 140 140 0.73 0.72 0.69 0.66 0.61 0.57 104 102 98 94 86 80 20 22 26 30 34 37 330 303 252 202 134 70 92 84 70 56 37 19 40 76 138 207 282 336 110 110 110 110 0.58 0.56 0.54 0.52 68 65 62 59 15 20 27 29 236 161 90 48 66 45 25 13 18 82 166 199 80 80 80 0.42 0.41 0.40 36 35 34 11 14 17 140 92 30 39 26 8 11 37 65 Legend U I P : Fan motor power supply : Current draw : Power input to the fan motor, numeric controller or speed controller r/s : Fan motor rotation speed (seconds) Qv : Air flow Pressure : Available static pressure 41 11.7.4 - ICM size 4.4 with electrical heater, and 5-row cooling coil U (V) I (A) P (W) r/s Qv m3/h Qv l/s Pressure Pa 230 230 230 230 230 230 230 230 230 230 0.82 0.78 0.76 0.72 0.69 0.66 0.64 0.62 0.61 0.60 182 182 168 159 151 142 136 130 127 125 21 22 22 22 23 23 23 23 24 24 964 862 811 708 603 499 405 311 239 171 268 239 225 197 168 139 112 86 67 47 37 80 98 130 156 178 195 210 218 227 230 200 200 200 200 200 200 200 200 0.59 0.75 0.72 0.67 0.59 0.55 0.52 0.50 0.49 123 150 143 133 117 109 101 97 96 24 20 21 21 22 23 23 23 24 97 873 812 695 506 396 277 178 109 66 242 226 193 140 110 77 49 30 237 46 70 114 164 184 202 214 222 170 170 170 170 170 170 170 170 0.71 0.67 0.62 0.57 0.52 0.48 0.46 0.44 121 114 106 98 89 83 78 75 18 19 20 21 22 22 23 23 761 700 596 498 396 304 218 125 211 194 166 138 110 84 61 35 46 77 114 142 166 183 197 208 140 140 140 140 140 140 0.65 0.59 0.53 0.46 0.43 0.41 90 82 74 65 62 58 17 18 20 21 22 22 595 497 404 287 204 95 165 138 112 80 57 26 47 95 132 164 182 199 110 110 110 110 110 0.55 0.51 0.45 0.43 0.40 61 56 50 48 48 14 17 19 20 20 404 325 233 179 82 112 90 65 50 23 43 87 127 143 169 80 80 80 80 0.43 0.41 0.41 0.39 34 33 3 31 11 13 14 15 216 180 146 69 60 50 64 19 33 52 64 79 Legend U I P : Fan motor power supply : Current draw : Power input to the fan motor, numeric controller or speed controller r/s : Fan motor rotation speed (seconds) Qv : Air flow Pressure : Available static pressure 42 11.8 - Air flow/available static pressure data 11.8.1 - ICM size 1.3 Available static pressure curve (Pa) as a function of air flow (m3/h or l/s) Pa 450 400 350 Available pressure, Pa 300 250 200 150 100 50 U=80 V U=140 V U=110 V U=170 V U=200 V U=230 V 0 14 28 42 56 70 84 98 112 126 140 154 168 182 l/s Air flow, Qv Legend U Without electric heater (with 6-row water coil) Fan motor power supply 43 11.8 - Air flow/available static pressure data (continued) 11.8.2 - ICM size 2.3 Available static pressure curve (Pa) as a function of air flow (m3/h or l/s) Available pressure, Pa Pa U=110 V U=140 V U=170 V U=200 V U=230 V U=80 V l/s Air flow, Qv Legend U 44 Without electric heater (with 6-row water coil) With electric heater (with 5-row water coil) Fan motor power supply 11.8 - Air flow/available static pressure data (continued) 11.8.3 - ICM size 4.4 Available static pressure curve (Pa) as a function of air flow (m3/h or l/s) Available pressure, Pa Pa l/s Air flow, Qv Legend U Without electric heater (with 6-row water coil) With electric heater (with 5-row water coil) Fan motor power supply 45 11.9 - Pressure diaphragm characteristics 11.9.1 - ICM sizes 1.3 and 2.3, 200 mm spigot diameter Pressure drop (Pa) as a function of air flow (m3/h or l/s) ∆P (Pa) 65 60 60 55 52 50 44 36 31 30 20 20 15 11 21 8 3 0 0 28 100 200 1 300 5 5 13 400 10 56 200 83 300 Air flow, Qv 46 30 600 25 0 650 35 700 40 500 Available pressure, Pa 45 111 400 139 500 167 600 194 l/s 700 m3/h 11.9 - Pressure diaphragm characteristics (continued) 11.9.2 - ICM size 4.4, 250 mm spigot diameter Pressure drop (Pa) as a function of air flow (m3/h or l/s) ∆P (Pa) 40 36 35 30 29 25 24 20 900 23 19 800 Available pressure, Pa 30 18 14 15 700 13 11 10 9 7 5 5 500 6 1 0 0 0 56 200 111 167 400 600 222 800 278 l/s 1000 m3/h Air flow, Qv 47 12 - CODIFICATION Characters Codification Type of unit Size of unit Air flow range Control Coil type Air filter access Fresh air controller Packaging Modification status Product source: Montluel Specials (digits 15,16 - reserved for the factory) Digit Codification Designation Digit 1, 2, 3, 4 ICM Type of unit 7,8 1 2 4 Size of unit ICM Size 1 ICM Size 2 ICM Size 4 5 6 Designation Electromechanical controller with fan speed controller B1 4P - Unit with fan speed controller protected by plastic cover with two on/off two-way water valve. B2 2P+2W - Unit with fan speed controller and electric heater relay protected by plastic cover, with on/off two-way water valve. B3 2P - Unit with fan speed controller protected by plastic cover with one on/off two-way water valve + flexible water pipes. Air flow range 3 144 l/s (520 m3/h), size 1.3 3 189 l/s (680 m3/h), sizes 2.3 4 264 l/s (950 m3/h), size 4.4 7,8 48 Codification Electromechanical controller with fan speed controller A0 2P/4P - Unit without valve, for two or four-pipe system with fan speed controller protected by plastic cover. B4 A1 2P+2W - Unit without valve, for two-pipe and two-wire system with fan speed controller and electric heater relay protected by plastic cover. 4P - Unit with fan speed controller protected by plastic cover with one on/off two-way water valve + flexible water pipes. B5 2P+2W - Unit with fan speed controller and electric heater relay protected by plastic cover, with one on/off two-way water valve + flexible water pipes. Digit Codification Designation Digit Codification Designation C3 2P/CO - Unit with fan speed controller protected by plastic cover with 1 on/off three-way water valve and changeover switch. E2 2P+2W - Unit with communicating controller, fitted with a return air sensor, 1 two-way on/off valve and electric heater control. C8 2P/CO - Unit with fan speed controller protected by plastic cover with 1 on/off three-way water valve and changeover switch + flexible water pipes. E3 2P - Unit with communicating controller, fitted with a return air sensor and 1 two-way on/off valve + flexible water pipes. E4 4P - Unit with communicating controller, fitted with a return air sensor and 2 two-way on/off valve + flexible water pipes. E5 2P+2W - Unit with communicating controller, fitted with a return air sensor, 1 two-way on/off valve and electric heater control + flexible water pipes. H0 2PC/O - Unit with communicating controller, fitted with 1 three-way on/off valve, complete with changover sensor. H1 2PC/O - Unit with communicating controller, fitted with 1 three-way on/off valve, complete with changover sensor + flexible water pipes. H2 2PC/O - Unit with communicating controller, fitted with a return air sensor and 1 threeway on/off valve, complete with changover sensor. H3 2PC/O - Unit with communicating controller, fitted with a return air sensor and 1 threeway on/off valve, complete with changover sensor + flexible water pipes. 7, 8 Carrier communicating controller D0 2P - Unit with communicating controller, fitted with 1 twoway on/off valve. D1 4P - Unit with communicating controller, fitted with 2 twoway on/off valves. D2 2P+2W - Unit with communicating controller, fitted with 1 two-way on/off valve, with electric heater control. D3 2P - Unit with communicating controller, fitted with 1 twoway on/off valve and flexible water pipes. D4 4P - Unit with communicating controller, fitted with 2 twoway on/off valves and flexible water pipes. D5 2P+2W - Unit with communicating controller, fitted with 1 two-way on/off valve, electric heater control and flexible water pipes. E0 2P - Unit with communicating controller, fitted with a return air sensor and 1 two-way on/off valve. E1 4P - Unit with communicating controller, fitted with a return air sensor and 2 two-way on/off valves. 49 Digit Codification 7, 8 Designation Codification Special control system XX 9 Unit with special control system. Plastic collar 6-row coil (consisting of 5 cooling rows and 1 heating row) B 5-row coil E 5-row coil and PTC electric heater. X 10 Designation Fresh air controller on fan motor access door (downstream of coil) Coil type A O 8 l/s (30 m3/h) P 17 l/s (60 m3/h), modifiable on site to 21, 28, 36 or 44 l/s U Without fresh air controller. 12 Packaging 5 10 units palletised 13 B Modification status 14 M Montluel factory Special coil Air filter access 1 Lateral access (polyvalent version) 2 Access from below (false ceiling version) 3 Top access (false floor version) 11 Fresh air controller 9 Basic unit with no fresh air inlet Fresh air controller in standard position (upstream of coil) 50 Digit A 8 l/s (30 m3/h) B 17-44 l/s (60-160 m3/h) (Modifiable on site to 21, 28, 36 or 44 l/s) G Without fresh air controller 15, 16 Specials 13 - SPECIFICATION GUIDE • Supply ICM fan coil units for VAV systems in accordance with the certified drawings. • The performance of each ICM unit supplied shall conform to the published technical and performance data. • The casings of ICMs units shall be made of galvanised steel 1 mm thick, thermally and accoustically insulated, and shall provide adequate access to all components for maintenance and repair. All ICMs units shall have suspension lugs with flat rubber pieces to absorb shock and vibration. • • • The electronic fan speed controller shall be compliant with most current commercial regulations (independent module). • It shall be possible to connect any ICM unit to electromechanical controllers (wall-mounted thermostats) which will enable the user to change the fan speed manually so as to adjust the unit’s heating and cooling capacity. • Electrical connections carried out on ICMs units shall be the quick connection type in order to simplify maintenance. The connection strip shall be protected by a recyclable ABS plastic cover. • The communicating Carrier numeric controller shall use the CCN (Carrier Comfort Network) communication protocol. The connection collar for supply and return air (2 x 199 mm diameter, 86 mm long for sizes 1.3 and 2.3 and 2 x 249 mm diameter, 86 mm long for size 4.4) shall be integral with each ICM unit. This controller shall provide the following functions: Control fan speed on the ICM between a parameterised minimum and maximum hot or cold air flow Control the flow of water through the two or threeway, on/off type valves by reference to internal and external loads to maintain a constant ambient temperature in the air conditioned space Provide on/off control or electric heater capacity (PTC) Turn lighting sources on and off Adjust window blinds (raise/lower/angle) Be controlled by a Zone User Interface with numric display or by a wall-mounted thermostat. The fresh air connection collar shall be 125 mm in diameter and shall be integral with each ICM unit. The collar shall be located : - upstream of the air filter and upstream of the exchange coils to enable the fresh air to be conditioned. - downstream of the air filter and exchange coils if the fresh air is pre-conditioned and filtered. It shall be connected to the main primary air distribution duct via the extending flexible pipe which is available as an optional extra. The fresh air flow must be between 30 and 160 m3/h (8.3 and 44.4 l/s). • Each ICM unit supplied shall be fitted with a changeover heating or cooling coil, or a monobloc heating or cooling coil, or a cooling coil in association with an electric heater. Water coils shall have manual bleed valves. • Five-row cooling coils and one-row heating coils shall be made of copper tubes with 3/8" external diameter and aluminium fins. The operating pressure for water shall not exceed 10 bar. • The condensate drain pan beneath the coil and valves shall be monobloc and made of ABS to prevent the possibility of leaks. • The two-way or three-way motorised water flow control valves shall be provided with flexible water pipes fitted with 1/2" threaded nuts to simplify site connections and maintenance work. Actuators shall be of the on/off electrothermal type. • Each ICM unit shall have a disposable, high-performance air filter type F5 and M1 fire rating. • The power supply to the controller shall be 230 V a.c. 10%, single-phase, 50 Hz, to avoid the need for a transformer. The electric heater shall be controlled directly by the Carrier numeric controller to avoid the need for a power triac. Access to the filter shall be from the top, bottom or side of the unit according to choice. • The fan shall be a centrifugal, single-wheel type with single or double inlet. The available static pressure shall be sufficient to enable units to be installed outside the air conditioned space (i.e. greater than 100 Pa) in order to simplify maintenance. • The direct-drive fan motor shall be connected to a fan speed controller or integrated with the communicating numeric controller. It shall be protected against overloads. Motor connections shall conform to Class B for insulation and Class F for varnish, and shall have IP44 electrical protection. 51 Carrier S.A.S. Demonstration Suite Whether you live in the tropics or in Greenland Whether you suffer from the heat, from the cold or from lack of air CARRIER has the solution and can show it to you in the demonstration suite The programmes available ✔ simulation of the climate in your region ✔ simulation of the heating and cooling loads according to your needs ✔ measuring, storing and display of the air temperatures and the air distribution pattern taking into account your climatic and architectural constraints - even at climatic extremes ✔ optimisation of the physical location of the air terminals in your building walls or ceilings ✔ determination and control of the sound level in every room ✔ simulation of the control system of your terminals and their link to your BMS system ✔ and finally, simulation of how your interior will look, with a floor plan, lights and blinds to ensure true quality Experience a real preview of your future installation No 14227-20, 05.2005 - Supersedes No: 14217-20, 07.2002. Manufacturer reserves the right to change any product specification without notice. Manufacturer: Carrier s.a., Montluel, France Printed in France
Similar documents
ETON America - Get 2 It Sales, LLC
All information, illustrations, directions and specifications included in this publication are based on the latest product information available at the time of approval for printing. E-TON Dynamic ...
More information