1020 Series - Bloom Engineering
Transcription
1020 Series - Bloom Engineering
Bloom Engineering Company, Inc. April 2013 1020 Series Fixed Thermal Release (FTR) Cold Air Refractory Baffle Burner APPLICATIONS Steel Reheating Furnaces Ladle Dryers Ingot Heaters Air Heaters Hot Metal Mixers Boilers Copper and Aluminum Melting & Holding Furnaces Many other Applications FEATURES Rugged fabricated construction Refractory baffle stabilization shields the burner internals from flame and is a selfsupporting stable structure Suitable for operation at furnace temperatures up to 2600 ˚F Heat resistant alloy nozzle CAPABILITIES High heat release rates with moderate air pressure Good turndown with flame characteristics and direction maintained Stable flame shapes tailored to the job www.bloomeng.com CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations 1020 Series Bulletin Bloom Engineering Company, Inc. Table 1 - Performance and Selection Chart - Fast Heat Release1 (Short Flame) - 12" w.c. (30 mbar) Air Pressure* Burner Designation 1020 - ___ Max Air Capacity 2 at 12" w.c. (30 mbar) Air Pressure scfh Oil Burner Size Nm3/hr FET 1820- LP 1920- Pilot Part Number 3 3001-___ -040 30,800 825 20 20 -050 -060 46,200 1,238 30 30 -050 -065 61,600 1,651 30 45 -050 -080 93,300 2,500 60 60 -050 -085 116,600 3,124 80 60 -050 -100 155,000 4,153 100 100 -100 -120 217,800 5,836 125 150 -100 -140 264,000 7,074 140 175 -100 -160 330,000 8,843 175 220 -150 -180 407,000 10,906 240 220 -150 -200 484,000 12,969 300 330 -150 -220 583,000 15,622 300 330 -150 -240 682,000 18,275 400 330 -150 * See Table 3 for Flame Dimension Options Table 2 - Performance and Selection Chart - Fast Heat Release1 (Short Flame) - 6" w.c. (15 mbar) Air Pressure* Burner Designation 1020 - ___ Max Air Capacity 2 at 6" w.c. (15 mbar) Air Pressure scfh Nm3/hr FET 1820- LP 1920- Pilot Part Number 3 3001-___ -040 22,000 590 15 15 -050 -060 33,000 884 20 20 -050 -065 44,000 1,179 30 30 -050 -080 66,000 1,769 45 45 -050 -085 82,500 2,211 45 45 -050 -100 110,000 2,948 60 60 -100 -120 154,000 4,127 80 100 -100 -140 220,000 5,895 125 150 -100 -160 264,000 7,074 140 175 -150 -180 330,000 8,843 175 220 -150 -200 412,000 11,040 240 220 -150 -220 500,000 13,398 300 330 -150 -240 590,000 15,809 300 330 -150 Oil Burner Size * See Table 4 for Flame Dimension Options 1 Heat release tailored to suit application 2 at 100˚F (38˚C) Air Temperature 3 Pilots operate at 4" w.c. mixture pressure at the tip CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations 2 1020 Series Bulletin Bloom Engineering Company, Inc. Table 3 - Flame Dimensions - Fast Heat Release1 (Short Flame) - 12" w.c. (30 mbar) Air Pressure* Baffle: straight holes w/ standard port Flame Length 2 Baffle: 15˚ spin holes w/ standard port Flame Diameter 2 Flame Length 2 Flame Diameter 2 Burner Designation 1020 - ___ feet meters feet meters feet meters feet meters -040 5 1.5 1.5 0.5 3.5 1.1 2.5 0.8 -060 6.5 2.0 1.5 0.5 5 1.5 2.5 0.8 -065 7.5 2.3 2 0.6 5.5 1.7 2.5 0.8 -080 10 3.0 2 0.6 7.5 2.3 3 0.9 -085 11.5 3.5 2 0.6 9 2.7 3.5 1.1 -100 14.5 4.4 3 0.9 11 3.4 4 1.2 -120 18 5.5 3.5 1.1 13 4.0 4.5 1.4 -140 20 6.1 3.5 1.1 14.5 4.4 5 1.5 -160 22 6.7 4 1.2 16 4.9 5.5 1.7 -180 24.5 7.5 4.5 1.4 17.5 5.3 6 1.8 -200 27 8.2 4.5 1.4 19.5 5.9 6.5 2.0 -220 29 8.8 4.5 1.4 21.5 6.6 6.5 2.0 -240 31 9.4 5 1.5 22.5 6.9 7 2.1 Baffle: 25˚ spin holes w/ standard port Flame Length 2 Burner Designation 1020 - ___ feet meters -040 2.5 -060 4 -065 -080 -085 Baffle: 25˚ spin holes w/ special port Flame Diameter 2 feet meters 0.8 3 1.2 3.5 4.5 1.4 3.5 6 1.8 4 7 2.1 -100 8.5 -120 10.5 -140 -160 -180 Flame Length 2 Flame Diameter 2 feet meters feet meters 0.9 2 0.6 3.5 1.1 1.1 2.5 0.8 4 1.2 1.1 3 0.9 4 1.2 1.2 4.5 1.4 4.5 1.4 4.5 1.4 5 1.5 5 1.5 2.6 5 1.5 6.5 2.0 5.5 1.7 3.2 6 1.8 8 2.4 6.5 2.0 11.5 3.5 6.5 2.0 9 2.7 7 2.1 13 4.0 7 2.1 10 3.0 8 2.4 14.5 4.4 7.5 2.3 11 3.4 8.5 2.6 -200 16 4.9 8.5 2.6 12 3.7 9 2.7 -220 17.5 5.3 9 2.7 13 4.0 10 3.0 -240 18.5 5.6 9.5 2.9 14 4.3 10.5 3.2 * See Table 1 for Performance and Selection 1 Heat release tailored to suit application 2 Flame lengths and diameters are approximate with 10% excess air CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations 3 1020 Series Bulletin Bloom Engineering Company, Inc. Table 4 - Flame Dimensions - Fast Heat Release1 (Short Flame) - 6" w.c. (15 mbar) Air Pressure Baffle: straight holes w/ standard port 2 Baffle: 15˚ spin holes w/ standard port 2 Flame Length 2 Flame Diameter 2 Burner Designation 1020 - ___ feet meters feet meters feet meters feet meters -040 6 1.8 1.5 0.5 3.5 1.1 2.5 0.8 -060 7.5 2.3 1.5 0.5 5 1.5 2.5 0.8 -065 9 2.7 2 0.6 5.5 1.7 2.5 0.8 -080 11 3.4 2 0.6 7.5 2.3 3 0.9 -085 13 4.0 2 0.6 9 2.7 3 0.9 -100 16 4.9 2.5 0.8 11 3.4 3.5 1.1 -120 21 6.4 3 0.9 13 4.0 4 1.2 -140 26 7.9 3.5 1.1 16.5 5.0 4.5 1.4 -160 28 8.5 3.5 1.1 18 5.5 5 1.5 -180 31 9.4 4 1.2 20.5 6.2 5.5 1.7 -200 34 10.4 4.5 1.4 23 7.0 6 1.8 -220 36 11.0 4.5 1.4 25.5 7.8 6.5 2.0 -240 38 11.6 4.5 1.4 27.5 8.4 6.5 2.0 Flame Length Flame Diameter Baffle: 25˚ spin holes w/ standard port 2 Baffle: 25˚ spin holes w/ special port 2 Flame Length 2 Flame Diameter 2 Burner Designation 1020 - ___ feet meters feet meters feet meters feet meters -040 2.5 0.8 3 0.9 2 0.6 2 0.6 -060 4 1.2 3 0.9 2.5 0.8 2.5 0.8 -065 4.5 1.4 3 0.9 3 0.9 3 0.9 -080 6 1.8 3.5 1.1 4.5 1.4 4.5 1.4 -085 7 2.1 4 1.2 5 1.5 5 1.5 -100 8.5 2.6 4.5 1.4 6.5 2.0 6.5 2.0 -120 10.5 3.2 5 1.5 8 2.4 8 2.4 -140 13 4.0 6 1.8 10.5 3.2 10.5 3.2 -160 14.5 4.4 6.5 2.0 11.5 3.5 11.5 3.5 -180 16 4.9 7 2.1 13 4.0 13 4.0 -200 18 5.5 8 2.4 14.5 4.4 14.5 4.4 -220 20 6.1 8.5 2.6 16 4.9 16 4.9 -240 22 6.7 9 2.7 17.5 5.3 17.5 5.3 Flame Length Flame Diameter * See Table 2 for Performance and Selection 1 Heat release tailored to suit application 2 Flame lengths and diameters are approximate with 10% excess air CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations 4 1020 Series Bulletin Bloom Engineering Company, Inc. Table 5 - Performance and Selection Chart - Slow Heat Release1 (Long Flame) - 3" w.c. (7.5 mbar) Air Pressure Max Air Capacity2 at 3" w.c. (7.5 mbar) Air Pressure scfh Nm3/hr FET 1820- LP 1920- feet meters feet meters Pilot Part Number 3 3001-___ -040 22,000 590 15 15 8 2.4 1.5 0.5 -050 -060 33,000 884 20 20 9 2.7 1.5 0.5 -050 -065 44,000 1,179 30 30 12 3.7 2 0.6 -050 -080 66,000 1,769 45 45 16 4.9 2 0.6 -050 -085 82,500 2,211 45 45 18 5.5 2 0.6 -050 -100 110,000 2,948 60 60 21 6.4 2.5 0.8 -100 -120 154,000 4,127 80 90 28 8.5 3 0.9 -100 -140 220,000 5,895 125 120 36 11.0 3 0.9 -100 -160 264,000 7,074 140 180 39 11.9 3.5 1.1 -150 -180 330,000 8,843 175 180 43 13.1 4 1.2 -150 -200 412,000 11,040 240 240 46 14.0 4 1.2 -150 -220 500,000 13,398 300 240 46 14.0 4 1.2 -150 -240 590,000 15,809 300 - 46 14.0 4 1.2 -150 Burner Designation 1020 - ___ Oil Burner Size Flame Length 4 Flame Diameter 4 Table 6 - Performance and Selection Chart - Slow Heat Release1 (Long Flame) - 6" w.c. (15 mbar) Air Pressure 1 Max Air Capacity2 at 3" w.c. (7.5 mbar) Air Pressure scfh Nm3/hr FET 1820- LP 1920- feet meters feet meters Pilot Part Number 3 3001-___ -040 22,000 590 15 15 8 2.4 1.5 0.5 -050 -060 33,000 884 20 20 9 2.7 1.5 0.5 -050 -065 44,000 1,179 30 30 12 3.7 2 0.6 -050 -080 66,000 1,769 45 45 16 4.9 2 0.6 -050 -085 82,500 2,211 45 45 18 5.5 2 0.6 -050 -100 110,000 2,948 60 60 21 6.4 2.5 0.8 -100 -120 154,000 4,127 80 90 28 8.5 3 0.9 -100 -140 220,000 5,895 125 120 36 11.0 3 0.9 -100 -160 264,000 7,074 140 180 39 11.9 3.5 1.1 -150 -180 330,000 8,843 175 180 43 13.1 4 1.2 -150 -200 412,000 11,040 240 240 46 14.0 4 1.2 -150 -220 500,000 13,398 300 240 46 14.0 4 1.2 -150 -240 590,000 15,809 300 - 46 14.0 4 1.2 -150 Burner Designation 1020 - ___ Oil Burner Size Flame Length 4 Flame Diameter 4 Heat release tailored to suit application 2 at 100˚F (38˚C) Air Temperature 3 Pilots operate at 4" w.c. mixture pressure at the tip 4 Flame lengths and diameters are approximate with 10% excess air CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations 5 1020 Series Bulletin Table 7 - Burner Dimensions K—dia. 4 holes Observation Port H G Square H Bloom Engineering Company, Inc. 125# Standard Air Flange Data: R—O.D. , O—B.C., P—Dia. S—Holes equally spaced straddling centerlines T C A air D AB AA 2” Customer to have a good seal 2” E B gas N M Port block by customer. Surface must be smooth and free of irregularities B—125# Standard Flange Connection 12 9/16 NOTE: General Dimension Information. See Bloom Representative for certified dimensions for construction CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations 6 1020 Series Bulletin Bloom Engineering Company, Inc. Table 8 - Gas Line Size Chart Table 9 - Excess Air Limits Rich Gaseous Fuels Burner Air Static Pressure Rating Baffle Design Oil (LP Burner) Oil (FET Burner) "w.c. mbar No Spin 25˚ Spin Distillate Distillate Residual 3 7.5 1500 - 2000% - N/A N/A N/A 6 15 400 - 500% 500 - 750% 100 - 150% 100 - 150% 50 - 60% 12 30 200 - 300% 300 - 500% 100 - 150% 100 - 150% 50 - 60% Table 10 - Standard Port Block Dimensions B square A F D G NOTES: General Dimension Information. See Bloom Representative for certified dimensions for construction The port block is normally rammed as an integral portion of the furnace wall. However, refractory port blocks are available at extra cost CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations 7 1020 Series Bulletin Bloom Engineering Company, Inc. Table 11 - Spare Parts List Flame Safety Lighting Hole Lighting Hole Flame Safety Part Number 01 02 03 06 07 Description Body Baffle Nozzle Assembly Observation Port Port Block Part Number Must be Preceded by Catalog Number (EXAMPLE: To Order Baffle Part 02 for 1020-080 Burner, specify 1020-080-02) Table 12 - Lighting Hole and Flame Safety Connection Sizes and Details * Please consult Bloom Representative for selection of direct spark igniter type NOTE: General Dimension Information. See Bloom Representative for certified dimensions for construction CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations 8 1020 Series Bulletin Bloom Engineering Company, Inc. Application Guidelines * FUEL CAPABILITIES **: Natural Gas LP Gas Coke Oven Gas Blast Furnace Gas #2 through #6 Oil Low Btu/Calorific Mixed Gas **Please Consult a Bloom Representative for availability of other fuel types BURNER IGNITION: Pilot Direct Spark Manual CONTROL: Volumetric Fuel/Air Ratio Pressure Balance Ratio Regulators Tandem Valves NOTE: Because low gas pressure the burner design, it is recommended that gas distribution orifice plates are installed at each burner in multiple burner zones FLAME MONITORING: UV Detector NOTE: Please contact your Bloom Representative for flame monitoring with residual oils OPTIONS: Round mounting flange Round mounting flange Clean-out Doors or Couplings Vertical Firing Removable end plate Angled Mounting flange Alloy patch plate Burner block / tile Air or gas lance for increased turndown Angled air riser * NOTE: Due to continual developments in the Bloom Laboratory and results from field research, the applicability of different fuels and other options listed above are constantly being updated. Please consult a Bloom Representative to inquire about the availability of any guidelines/options that are not shown above. SPARE OR REPLACEMENT PARTS Spare Parts and Replacement parts are available for virtually all industrial burners and combustion systems supplied by Bloom Engineering in the past 50 years. Spare and replacement parts are manufactured to original dimensions and tolerances to ensure performance is maintained. For more information, please visit our website at www.bloomeng.com/burner-spare-parts. CAUTION: The improper use of combustion equipment can result in a condition hazardous to people and property. Users are urged to comply with National Safety Standards and/or Insurance Underwriters recommendations 99 1020 Series Bulletin Bloom Engineering Company, Inc. To REQUEST A QUOTE *, Please Contact your local representative at www.bloomeng.com/locate-arep and provide the following information: INFORMATION UNITS General Information: Application - Burner Input (MMBtu/hr; kcal/hr; kW) in (HHV or LHV) Quantity of Burners - Ignition Type and Fuel - Main Fuel Information: Fuel (s) and Heating Value (s) (Btu/ft3; kcal/Nm3; MJ/Nm3) in (HHV or LHV) Fuel Flow (scfh; Nm3/hr) Available Fuel Pressure (“w.c.; psi; mbar; kPa) Fuel Constituents - Combustion Air Information: Combustion Air Temperature (˚F; ˚C) Combustion Air Pressure Available (“w.c.; psi; osi; mbar; kPa) Minimum / Maximum Excess Air Required (%) Flame Information: Desired Flame Length (feet; inches; m; mm) Desired Flame Diameter (feet; inches; m; mm) Furnace / Combustion Chamber Information: Wall thickness (feet; inches; m; mm) Burner Assembly / Connection Requirements - Furnace / Chamber Dimensions or Drawings for Emissions estimate - POC (Products of Combustion) / Furnace Temperature (˚F; ˚C) Other Information: Operational / Control Requirements (i.e. Turndown, Control Type) - Emissions Requirements (NOx, CO) - Chamber Backpressure - Oil / Atomizing agent Details - Any other special requirements - * NOTE: Information required to process a quote includes, but may not be limited to, the information specified above. Additional details may also be required to quote a combustion control system. Bloom Engineering Company, Inc. For more details and a complete listing of products, please visit our website at: www.bloomeng.com/industrial-burners Corporate Headquarters 5460 Horning Road Pittsburgh, PA 15236-2822 Main: 412-653-3500 Email: [email protected] Web: www.bloomeng.com 1010