communication system hcc-07.2

Transcription

communication system hcc-07.2
COMMUNICATION SYSTEM HCC-07.2
Nurse Call
COMMUNICATION SYSTEM HCC-07.2 Nurse Call
THE NEW MODEL SERIES WITH A TOUCH SCREEN INITIATES AN
ENTIRELY NEW TREND IN HOSPITAL COMMUNICATIONS SYSTEMS
The system offers a highly comfortable and clearly organised graphical user environment combined with simplicity of
operation and control by function keys directly on the touch screen.
This new system provides patients with high-quality, convenient voice communication with attending staff, connection
of calls from the public telephone network to their bedside, and access to entertainment programs by the use of
a bedside unit. Recording the history of all types of calls, precise localisation of the calling site and the operator’s
response time are a matter of course.
The system is designed primarily for health care and for social care facilities – hospital inpatient departments, medical
institutions and sanatoria. This up-to-date communications equipment complies, in its basic principles, with all the
European standards that are required of similar devices used in hospital-type environments.
Main terminal MT-07.2
The systems installed in individual departments can be connected as an integrated operational whole, which facilitates
the creation of larger functional units with centralised management, e.g. during night hours.
THE MAJOR ADVANTAGES OF THE MAIN TERMINAL MT-07.2
■ Clearly organised service panel with direct touch-screen control
■ Clearly legible colour LCD display
■ Unlimited number of calling sites
■ Calling a subscriber by speed dial
■ Option of discrete or speaker-on voice communication between medical staff and patients
■ Speaker-on transmission of information to all rooms within one department
(central announcements)
■ Visual representation and localisation of staff presence on the terminal display
■ Connecting of calls coming through a public network to an in-patient’s bed
■ Records of the history of all types of calls
■ Recording the user’s name
■ Night operation
MT-07D.2
55°
ERGONOMIC DESIGN
TOUCH SCREEN
WALL INSTALLATION
NEW FEATURES
■ Communication with the main terminal by means of LAN through the use
of up-to-date VoIP technology
■ 10.4” LCD panel (main terminal) with direct control on the touch screen
■ Ergonomic positioning of the terminal
■ Variable positions – on the table or on the wall
■ LAN interface for connection to the computer network
■ USB port for data backup and SW upgrade
■ Visual representation of the location of registered personnel (NURSE PRESENCE)
■ Transferring operation to another department – support for joining departments
into larger units with centralised management of up to 10 departments (WARD COUPLING)
■ Time filters for displaying calls (TIME ZONE NURSING)
■ Extended records of the history of calls (times of call activation and of call processing)
■ PHP server, on-line visual representation of the current status of main terminal, displaying the history of calls directly on the PC
SPEED DIAL
USB - INTERFACE
VoIP - LAN
CLEAR ARRANGEMENT AND EASE OF OPERATION
Listening unit
PB-07.2
■ Centralised listening to an entertainment program heard
by all users through their communication units
Entrance-door voice communication unit
HV-07.2
■ ‘Call a nurse’ activation button
■ Two-way speaker-on voice communication
■ A full substitute for a so-called electronic doorkeeper at
the entrance door; with the possibility of activation of an
electric lock
LED signal light
SS-07L
■ Optical indication whereby types of calls are differentiated
In-room control box
CB-07.2
■ Emergency call activation button
■ ‘BLUE CODE’ activation to summon a doctor
or another helper
■ Detecting the presence of a staff person in a room
■ Receiving all types of calls from other rooms
In-room control communication box
CB-07H.2
■ ‘Call a nurse’ activation button
■ ‘BLUE CODE’ activation to summon a doctor
or another helper
■ Detecting the presence of a staff person in a room
■ Receiving all type of calls from other rooms
■ Two-way speaker-on voice communication
■ Communication with any calling subscriber
■ Listening to the central announcements transmitted from
the main terminal
In-room control box with a display
CB-07D.2
■ ‘Call a nurse’ activation button
■ ‘BLUE CODE’ activation to summon a doctor
or another helper
■ Detecting the presence of a staff person in a room
■ Receiving all type of calls from other rooms
■ Two-way speaker-on voice communication
■ Communication with any calling subscriber
■ Displaying the type of call and the caller’s localisation
■ Listening to the central announcements transmitted from
the main terminal
Calling cord with
a microphone VS-07M.2
■ ‘Call a nurse’ activation button
■ Speaker-on call and listening to
entertainment programmes through
a speaker by means of a socket
■ Volume control for entertainment
programmes
■ Receiving phone calls from the public
telephone network
■ Easy identification of the call activation
button during night hours (NIGHT BUTTON)
Calling cord with a light
control VS-07L.2
■ ‘Call a nurse’ activation button
■ Speaker-on call through a speaker by
means of a socket
■ Receiving phone calls from the public
telephone network
■ Control of two lighting fixtures
■ Easy identification of the call activation button
during night hours (NIGHT BUTTON)
NIGHT
■ Emergency call acoustic activation
t
■ Emergency call activation by means of
a pneumatic switch socket
Acoustic switch
AS-07.2
Nigh
Pneumatic switch
PS-01.2
od
e
m
■ ‘Call a nurse’ activation button
■ Discrete voice communication and
listening to entertainment programmes
■ Speaker-on call and listening to an
entertainment programmes through
a speaker by means of a socket
■ Volume control for entertainment programmes
■ Receiving phone calls from the public telephone network
■ Control of two lighting fixtures
■ Easy identification of the call activation button during
night hours (NIGHT BUTTON)
N
TO
Bedside communication unit
with a light control SL-07L.2
BU
T
RELIABLE OPERATION
Bedside socket with a speaker
ZP-07R.2
■ Connection of bedside voice communication and signalisation components
■ Discrete or speaker-on voice communication
■ Speaker-on function for entertainment programmes and
central announcements
■ Usually installed on a lighting and installation panel above
the patient’s bed
Bedside socket
ZP-07.2
■ Connection of bedside voice communication and signalisation components (variant without a speaker)
■ Usually installed on a lighting and installation panel above
the patient’s bed
Pneumatic switch socket
ZS-07.2
■ Connection of a pneumatic switch for the activation of
emergency calls
Bedside socket with a holder for a receiver
and/or button and with speaker ZP-07DR
■ Connection and suspension of bedside
voice-communication and signalisation components
■ Discrete or speaker-on voice communication
■ Speaker-on function for entertainment programmes and
for central announcements
Bedside socket with a holder for a receiver
and/or button ZP-07D
■ Connection and suspension of bedside
voice-communication and signalisation components
(variant without a speaker)
Holder for a receiver and/or button DS-07
■ Suspension of bedside voice-communication and
signalisation components
Speaker unit
RJ-07
■ Listening to central announcements transmitted from
the main terminal
Light and installation panel
k
Socket Z
P-
R
07
t
ke
c
o
with a ho
lde
r
ZP
S
.2
So
c
Socket Z
P-
r
DR
-07
D
-07
So
c
h a hold
e
.2
07
wit
et
ZP
h a hold
wit
er
et
ZP
k
GREATER USER COMFORT
wa
ll
Hold
er
e
DS
7DR
-0
nstalled on
i
7
th
-0
Information display
DI-07
■ Date and time display
■ Identification of all types of calls and
localisation of origin of call
Emergency call button
TK-07.2
Emergency call button and
drawstring TH-07.2
■ Emergency call activation button
■ Emergency call activation button and
drawstring
Cordless portable button
BT-07.2
■ Cordless activation of emergency calls
■ Worn suspended round the neck or attached
to the arm
■ in connection with either
ZP-07.2 or ZP-07R.2
3
4
5
3
MODEL LOCATION OF COMPONENTS
4
Nurse station
Examination room
12
1
Doctor’s
room
13
Corridor
7
3
4
9
1
2
Bedside socket with
a holder for a receiver and/
or button and with speaker
ZP-07DR
Calling cord with a
microphone VS-07M.2
3
In-room control
communication box
CB-07H.2
5
Listening unit
PB-07.2
6
Entrance-door voice
communication unit
HV-07.2
8
Emergency call
button and
drawstring TH-07.2
9
11
Room control box
CB-07.2
12
Entrance
7
9
4
3
8
2
Bedside
communication unit
with light control
SL-07L.2
6
7
Bedside socket with
a holder for a receiver
and/or button ZP-07D
4
11
In-room control
box with a display
CB-07D.2
8
7
8
Patient room
Patient room
1
2
LED signal light
SS-07L
9
Ward bathroom
10
8 10
Pneumatic switch socket
ZS-07.2
Pneumatic switch
PS-01.2
Main terminal
MT-07.2
VARIANTS
1
2
13
3
4
8 10
Information display
DI-07
Emergency call
button TK-07.2
BUSINESS
DIVISION
DATACOM Systems, s.r.o.
Křížkovského 112, 757 01 Valašské Meziříčí
Czech Republic
tel.: +420 571 615 910, fax: +420 571 615 920
cell phone: +420 777 555 655, (Petr Nachtigal, Ph.D)
e-mail: [email protected], [email protected]
www.dcs-cz.eu
w w w . c o d a c o . c z
PR 0007 2010/03
CREATORS OF ELECTRONIC SYSTEMS
ISO 9001:2008