Spa Install Instructions
Transcription
Spa Install Instructions
COPACABANA MOJITO MARGARITA PINA COLADA PORTABLE VERSION AND PORTABLE WITH REMOTE INSTALLED SPA PACK INSTALLATION AND OPERATING INSTRUCTIONS To be read carefully and kept for future reference. You have just acquired a portable spa from the PROCOPI range, thank-you for placing your trust in us. All out spas provide an effective massage of the whole body and are very reliable and hard wearing. Please read this document carefully before attempting to install or use your spa. It contains important recommendations concerning the various functions along with the operating instructions. Keep this document and ensure it is read by all users. 2007/06 - Version : H - code : 0037811 SITING AND SAFETY RECOMMENDATIONS SITING RECOMMENDATIONS Carry the spa carefully to the installation site, this usually requires four people. The ground under the spa should be stable and perfectly level (check using a spirit level. If necessary use wedges to level the spa having first ensured that these wedges are strong enough to support the weight of the filled spa). Check that the ground, balcony or terrace will bear the total weight of the spa (plus water, plus occupants, see the table below) without any ill effect. We recommend that the spa be wired by a qualified professional. Refer to the French standard C15-100 for the the volumes that should be respected with regard to the installation of electrical appliances in the area surrounding the spa. If the spa is located outdoors: - the spa should be located at least 3.5m from any plug directly accessible and not protected by an obstacle. - the power line must be protected by a 30mA differential circuit breaker installed upstream and outside the protected volumes (0 to 3) (see the diagrams describing protected volumes around swimming pools on page 4). If the spa is located indoors: - the spa should be located at least 3.5m from any plug directly accessible and not protected by an obstacle. - the power line must be protected by a 30mA differential circuit breaker installed upstream and outside the protected volumes (0 to 3) (see the diagrams describing protected volumes around swimming pools on page 3). In accordance with French national regulations, there must be a total disconnect mechanism must be installed on the power line. If there is no isolating switch incorporated into the electrical connection between the differential circuit breaker and the spa, the circuit breaker must be capable of fulfilling this function is accordance with the stipulations of the French standard C15-100. Leave a space at least 80 cm wide around the entire periphery of the spa in case it is necessary to gain access to the area under the surround structure. - If the spa is installed in a small room, install a dehumidification system. SAFETY RECOMMENDATIONS - Always check the water temperature before getting into the spa. - Enter and leave the spa slowly and carefully. Wet surfaces could be slippery. - Never bring an electrical appliance into or near the spa. Never use an electrical appliance in the spa or if you are wet. - Do not use the spa if the drains (located at the bottom of the spa) are damaged or incomplete. - Exercise prudence and good sense when using the spa. Prolonged exposure to high temperatures can induce a rise in body temperature leading to dizziness, nausea, fainting, sleepiness or impaired consciousness which could lead to drowning. - People under the influence of alcohol or drugs should refrain from using the spa. Using the spa in this condition could have serious consequences. - People suffering from heart disease, diabetes, high or low blood pressure, or any condition monitored by a doctor, along with pregnant women, older people and young children should seek medical advice before using a spa. - Young children must be supervised by a responsible adult at all times. - Family pets should not be allowed in the spa. - Install the cover when the spa is not is use. - Damaged power cables should only be dealt with by your qualified installer. - Always cut the power supply to the spa before beginning any intervention on the electrical parts. - The wooden box (steps) protecting the spa pack (pump and other electrical components) must always be in place, except during maintenance when access to the spa pack may be necessary. 2/20 2007/06 - Version : H - code : 0037811 Protected volumes as defined in the French standard C15-100 Part 7 (Bath) Figure 701A - Dimensions of the volumes (plan) with fixed partitions at least 2.5 m high a) Bath Baignoire Outside safety volumes 1 0.60 m 0 2.25 m 2 2.25 m 3.00 m 3 Base: bottom ofla the bath Base : fond de baignoire Base de salle d'eau Base: bottom ofla the bathroom Space under bath 1 or 3 Espace sous lathe baignoire (voir (see701.320.5) 701.320.5) 2.40 m Volume 0 Volume 1 Volume 2 Volume 3 Figure 701B - Dimensions of the protected volumes (seen from above) a) Bath, with stationary partition a) Bath Volume 0 Volume 2 0.60 m Volume 3 2,40 m Volume 1 Volume 2 0.60 m Volume 3 2.40 m 0.60 m Volume 1 Volume 0 3/20 2007/06 - Version : H - code : 0037811 Protected volumes as defined in the French standard C-15-100 part 7 (pool) NOTE : Volume dimensions are delimited by walls and fixed partitions Figures 702B - Volume dimensions for above-ground pools Figures 702C - Example of volume dimensions (view from above) with fixed partitions at least 2.5 m high 4/20 2007/06 - Version : H - code : 0037811 Make sure that the ground will be able to bear the total weight of the spa (see the table). Ensure that a gap at least 80 cm wide has been left around the entire periphery of the spa to allow for access in the event of maintenance. PROVIDE FOR DRAINAGE 80 cm 80 cm 80 cm 80 cm Dimensions and reservations SPA W(mm) L (mm) H (mm) Weight (kg) * Copacabana 2210 2210 795 2300 Mojito 1955 1955 675 1620 Massage pump 1640 2090 675 1240 * SPA filled with water and the maximum number of occupants 80 cm 80 cm 80 cm 80 cm Dimensions and reervations SPA Margarita l (mm) L (mm) 1954 700 5/20 H (mm) 795 Weight (kg) * 1800 2007/06 - Version : H - code : 0037811 PREPARATION BEFORE COMMISSIONING ASSEMBLING THE TO SPA AND SPA PACK (PORTABLE VERSION) OPERATE CORRECTLY, THE SPA PACK DELIVERED WITH THE SPA SHOULD NOT BE INSTALLED REMOTELY BUT SHOULD BE INSTALLED ADJOINING THE SPA AS INTENDED BY THE MANUFACTURER. ANY MODIFICATION WILL ENTAIL THE ENTIRE RESPONSIBILITY OF THE PERSON WHO MADE THE MODIFICATION AND THE CANCELLATION OF THE GUARANTEE. Open the packet of seals and locking tubes delivered with the spa pack and identify the various items: Drain valve adaptor Blower hose locking screw Ozonator union o-ring Pump union o-rings (2 per pump) Ozonator tube Water return pump 3 (depending on the model) Suction pump 3 Water return pump 2 Suction pump 2 Blower (depending on the model) (depending on the model) (depending on the model) (depending on the model) Suction pump 1 Water return pump 1 Place the spa pack opposite the opening left for its connection at the base of the spa. The male connections of the spa pack should align perfectly with the female connections on the spa pack mounting plate. If necessary, alter the height of the anti-vibration pads (up to 8 mm) and loosen the pump screws to allow adjustment. LINES AND PIPES: Each union on the spa pack aligns with its corresponding circuit in the spa. Insert an o-ring and assemble each union with its corresponding part. Hand tighten the screws. The flexible vinyl hose belongs to the ozonator circuit. Join its union to the corresponding part of the same diameter on the spa. Use the small o-ring in the union. Connect the two tubes marked “OZONE”, one to the venturi on the hose, the other to the hose coming from the ozonator. There is no specific order of connection, the two tubes may be interchanged without any effect. Blower : Pull on the air tube and push the smooth union as far as possible into the mouth of the blower, do not glue. Insert the locking screw into the blower hole and tighten in order to lock the blower in position. 6/20 2007/06 - Version : H - code : 0037811 PREPARATION BEFORE COMMISSIONING ASSEMBLING THE THE SPA AND SPA PACK (PORTABLE SPAS WITH REMOTE INSTALLED SPA PACK) SPA PACK DELIVERED WITH THE SPA MAY BE INSTALLED EITHER ADJOINING THE SPA OR AT A DISTANCE OF UP TO 7.50 M FROM THE SPA. WHATEVER THE ASSEMBLING THE OPTION CHOSEN, THE SPA PACK MUST BE BELOW THE SPA WATER LEVEL. REMOTE INSTALL SPA PACK DIRECTLY AGAINST THE SPA: - The spa pack must be installed in a closed, dry location protected from the weather, vibrations, impacts, dust and water. - Due to the modifications made to allow remote installation of the spa pack it cannot be housed in the step. It must be installed against any of the other three sides. Open the packet of seals and locking tubes delivered with the spa pack and identify the various items: Union o-rings (2 per pump) Drain valve adaptor Ozonator union oring Pump union orings (2 per pump) Blower hose locking screw Place the spa pack opposite the opening left for its connection at the base of the spa. The male connections of the spa pack should align perfectly with the female connections on the spa pack mounting plate. If necessary, insert wedges under the spa pack or alter the height of the anti-vibration pads and loosen the pump screws to allow adjustment (refer to the previous paragraph). LINES AND PIPES: Each union on the spa pack aligns with its corresponding circuit in the spa. Insert an o-ring and assemble each union with its corresponding part. Hand tighten the screws. The flexible vinyl hose belongs to the ozonator circuit. Join its union to the corresponding part of the same diameter on the spa. Use the small o-ring in the union. Suspend the ozonotor hose loop at a point higher than the spa water level. Take care to ensure that the hose is not pinched or otherwise constricted. Blower : Pull on the air tube and push the smooth union as far as possible into the mouth of the blower, do not glue. Insert the locking screw into the blower hole and tighten in order to lock the blower in position. 7/20 2007/06 - Version : H - code : 0037811 REMOTE INSTALLATION OF THE SPA PACK (MAXIMUM 7.50 M) (OPTION) REMOTE SP 1200 (3 pumps) - : INSTALLATION KIT COMPOSITION SP 800X (2 pumps) 6 Spirabel water hoses 7.50 m / Ø 50 6 barbed half-unions with nut 6 barbed half-unions (threaded part) 1 solvent union Ø 25 10 meters of cristal hose Ø 26 1 pot of Pool-Tite glue 12 SS TORRO 40/60 clamps - SP 800 (1 pump) 4 Spirabel water hoses 7.50 m / Ø 50 4 barbed half unions with nut 4 grooved half unions (threaded part) 1 solvent union Ø 25 10 meters of cristal hose Ø 26 1 pot of Pool-Tite glue 8 SS TORRO 40/60 clamps - 2 Spirabel water hoses 7.50 m / Ø 50 2 barbed half-unions with nut 2 barbed half-unions (threaded part) 1 solvent union Ø 25 10 meters of cristal hose Ø 26 1 pot of Pool-Tite glue 4 SS TORRO 40/60 clamps Spa pack with Blower Remote install kits for spa packs with the Blower option include the following additional items: - 1 barbed union Ø 32 mm - 2 SS TORRO 20/40 clamps - 10 meters of air hose Ø 32 mm Female half-union Male half-union Barbed union SS TORRO 20/40 clamp Pumps: Use 1 barbed union at each pump outlet (2 per pump): - Screw the female half-union (with nut) onto a pump outlet (suction or return). - The other part of the half union (male) is screwed to the corresponding nut on the spa pack. Cut the Spirabel hose Ø 50 mm to the correct length and connect the two half-unions (secure on the barbed unions using the SS TORRO 40/60 clamps). Blower (spas with blower): Loosen the clamp and remove the hose (photo opposite). - On the spa pack side, slide the air hose , Ø 32 mm, onto the blower’s barbed union. - On the spa side, use the barbed union to connect the air hose, Ø32 mm, to that already in position on the spa. To facilitate sliding of the air hose onto the barbed unions, soften the ends by soaking them in water at about 40°C. Secure the hoses in position on the barbed unions using the TORRO 20/40 clamps. NB, spa packs sold separately: to protect the equipment, make a loop in the blower hose at the spa outlet. Ozonator: Use a solvent union Ø 25 mm Separate the two parts of the union: - screw the half-union with nut onto the male outlet of the spa pack. - secure the other part of the union to the end of the ozonator’s vinyl air hose. Cut the air hose, Ø 32 mm, to the correct length, glue each end to the half-unions with Pool Tite. 8/20 2007/06 - Version : H - code : 0037811 ELECTRICITY: Remove the front panel from the control panel to carry out the connections. Panel/spa connections Pull the spa’s electrical cables into the panel through the slots located on the right-hand side. Cables are colour coded according to their function. The following cables must be connected: - temperature probe (1) - Red - blower (depending on the spa model) - Yellow - underwater light(s) (1 or 2 depending on the spa model) - Blue - Touch pad(s) (1 or 2 depending on the spa model). Carefully connect each cable to its corresponding terminal in the upper right hand section of the electrical panel as described below. If there are several compatible terminals available (underwater lights, control panels) choose any, they all have the same function. underwater light(s) Blower Temperature probe Touch pad(s) Caution, under no circumstances should you touch the “DIP SWITCHES” circuit breakers located under the terminals. These control spa configuration and any manipulation could lead to malfunction. 230 volt 1ph power supply A H07RN-F cable must be used to connect the spa to the mains. Pull the 230 V + earth power cable into the panel through the cable gland located on the left side of the control panel. The cross section of this cable should be sized for all the spa equipment (refer to the table below), and protected upstream by a 30mA differential circuit breaker (French electrical standard C15-100). Connect the power cable to the terminal in the upper left section of the control panel. Replace the front panel. Connections should be checked at least three times a year. Dirty or incorrectly tightened connections could create short circuits and damage the control panel. SPA/Control panel wiring diagram SPA pack terminals Circuit breaker/fuse (provided by the client) P N P N Power supply 230V Power cabe Earth 9/20 2007/06 - Version : H - code : 0037811 CURRENT CABLE ABSORBED BY THE SPA PACKS AND CORRESPONDING CABLE CROSS SECTIONS LENGTH SP 1200-B SP 1200-SB SP 800-B Current (A) absorbed 29 A 23 A 14 A 12 A 21 A 16 A 5 metres 4 mm2 4 mm2 2.5 mm2 2.5 mm2 4 mm2 4 mm2 10 metres 6 mm2 4 mm2 2.5 mm2 2.5 mm2 4 mm2 4 mm2 15 metres 6 mm2 6 mm2 4 mm2 4 mm2 6 mm2 6 mm2 20 metres 10 mm2 6 mm2 4 mm2 4 mm2 6 mm2 6 mm2 35A 25A 16A 16A 25A 20A Electrical Not adjustable protection Adjustable SP 800-SB SP 800-XB SP 800X-SB Set the device to trip at the upper value + 2A The SP1200 spa pack is only used with the COPACABANA The SP800X spa pack can be used with the MOJITO and MARGARTIA TheSP800 spa pack can be used with the PINACOLADA Spa pack composition SP 1200-B SP 1200-SB SP 800-XB SP 800-XSB SP 800-B SP 800-SB Spa pack support plate 1 1 1 1 1 1 2-speed pump 1 1 1 1 1 1 Massage pump 2 2 1 1 - - Heater 3,5 kW 3,5 kW 2 kW 2 kW 2 kW 2 kW Control panel SP1200 SP1200 SP800 SP800 SP800 SP800 Touch pad 2 2 1 1 1 1 LED underwater light 2 2 1 1 1 1 Blower 1 - 1 - 1 - Power consumed by the various spa componants : Heater SP 1200 : Heater SP 800 : 2-speed pump : Massage pump : Blower : LED underwater light : Ozonator : 3.5 kW 2.0 kW 0.19 kW / 1.5 kW 1.5 kW 0.94 kW 0.035 kW 0.005 kW 10/20 2007/06 - Version : H - code : 0037811 FILLING THE SPA Open all the gate valves between the spa and the spa pack. Position the gate valve locking pins to hold the valves open. To ensure leak-tightness, make sure that the diverting valves are correctly tightened before filling the spa. (These valves may be loosened by vibration during transport.) Check that the spa gravity drain valve is closed and that the plug has been tightened correctly onto the valve. Note: leaktightness is ensure by the gasket at the bottom of the plug. Fill the spa The optimum water level with all users in the spa is indicated by the “WATER LEVEL” mark engraved on the skimmer frame. The low water level when no users are in the spa should be above the lower part of the skimmer mouth to avoid air being drawn in by the skimmer while spa water is being filtered. Water used: municipal water is the most reliable for filling the spa. Well water should be avoided due to the high concentrations of phosphates, nitrates, iron, manganese and, possibly, bacteria. If a water softener is available, fill the spa entirely or partially with softened water to avoid the build up of calcium deposits on the walls. If water is harder (Th) than usual (20°f) the water will need to be treated with a suitable product (AQUACAL) as soon as the spa is filled. Exposure to hard water can lead to yellowing of the plastic components (jets, skimmer, air control, etc.) located both above and below the water line. Start treating the water as soon as the spa is filled (refer to page 16). Check the water level regularly and adjust if necessary. Avoid over-filling the spa, otherwise the spa could overflow when people get in entailing irreversible damage to the blower and ozonator. Close the spa cover while the spa is not in use to prevent evaporation, heat loss and pollution of the spa water. EMPTYING PORTABLE SPAS All the spa models are fitted with gravity drains: - pull on the plug located on the left hand side of the spa pack and remove the drain hose. - Check that the valve is closed. - Unscrew the plug and replace it with the adapter that will accept the drain hose, then open the valve to empty the spa. The adapter is included with the spa pack. Valve 11/20 Adaptator 2007/06 - Version : H - code : 0037811 FIXING THE STEPS TO THE SPA CAUTION: POSITION AND BALANCE THE STEP CAREFULLY BEFORE FIXING THE STEP TO THE SPA Once the step is correctly positioned and balanced, screw it to the spa (through the two pre-drilled holes) using two screws VB FZ ST 5.0x80x50 SS A2 (screw driver + phillips head) 12/20 2007/06 - Version : H - code : 0037811 PRIMING THE PUMPS Prime the pumps before using the spa: - the filter cartridges should be removed from the skimmer to facilitate priming (see page 16). - loosen the union nut located on the pump suction line (horizontal pipe) in order to allow air to vent until water flows from the nut. - tighten the union connection and switch the pump on. The pump should prime and a burst of air should issue from the massage jets. - if the pump does not prime quickly, switch it off and start again. The spa pack may contain one, two or three pumps depending on the model. Repeat this procedure to prime each pump. Once the pumps have been primed, replace the filter cartridges. Massage pump 1 stop/start Filtration/massage : stop/start low/high speed Massage pump 2 stop/start Pump start/stop keys on the SP1200 touch pad Filtration/massage : Massage pump start /stop (depending on the model) stop/start low/high speed Pump start/stop keys on the SP800 / SP800X touch pads REFER TO THE SPA PACK TECHNICAL NOTICE FOR DETAILED INFORMATION CONCERNING THE VARIOUS FUNCTIONS. 13/20 2007/06 - Version : H - code : 0037811 USING THE SPA Each pump feeds massage jets in specific zones as marked out below. Pump 1 is a two-speed pump used alternately for filtration and hydrotherapy massage. Some zones are supplied by the same pump in an alternating sequence. Depending on its position, a diverting valve directs the flow from the pump to one zone or another. If the diverting valve is held in an intermediate position between two zones, this can create turbulence in the circuit and cause the jets to “whistle”. Switch the diverting valve completely to one position or another to silence this noise. Each zone features an Air Control that may be used to regulate the air flow through the massage jets. Note: A suction noise may be heard while the Air Control is set to allow air pass through the massage jets. IMPORTANT ! A FEW BUBBLES MAY ESCAPE FROM THE JETS WHILE THE AIR CONTROL IS CLOSED, THIS IS NORMAL. NEVER CLOSE ALL THE MASSAGE JETS IN ONE ZONE AT THE SAME TIME. LEAVE AT LEAST 3 JETS OPEN TO AVOID PLACING THE PUMPS UNDER UNNESSECCARY STRAIN WHICH COULD LEAD TO DAMAGE. A DELAY MAY BE NOTED BETWEEN THE OPENING OF THE AIR CONTROL AND THE ISSUING OF AIR BUBBLES FORM THE MASSAGE JETS, THIS DELAY IS NORMAL, IT CORRESPONDS TO THE TIME TAKEN TO PURGE THE JETS FURTHEST FROM THE AIR CONTROL. Below, the various zones with their corresponding air controls and diverting valves: COPACABANA touch pad Pump 1 Position 1 air control Pump 3 diverting valve fragrance diffuser (spas with blowers only) Pump 1 Position 2 Pump 2 Diverting valve pump 1 MOJITO Diverting valve pump 2 touch pad Pump 1 Position 2 air control Diverting valve fragrance diffuser Pump 1 Position 1 (spas with blowers only) Pump 2 Position 2 Pump 2 Position 1 Diverting valve pump 2 14/20 2007/06 - Version : H - code : 0037811 MARGARITA Diverting valve pour pump 2 Diverting valve pour pump 1 Pump 1 Position 1 touch pad air control Pump 2 Position 1 Pump 2 Position 2 Pump 2 Position 2 Pump 1 Position 2 Diverting valve fragrance diffuser (spas with blowers only) PINA COLADA Diverting valve pour pump 1 touch pad air control Diverting valve Pump 1 Position 1 fragrance diffuser (spas with blowers only) Pump 1 Position 2 Designation Description Diverting valve Allows the flow to be directed from the pump to one zone or another. air control Control the flow of air bubbles to the massage jets. Multi-directional jets 70 mm and 90 mm Multi-directional massage jets. The flow rate of each jet is controlled by turning the outer ring. Rotating jets, single or double jets Rotating massage jets. The flow rate of each jet is controlled by turning the outer ring. See maintenance page 16. Mini jet Constant flow rate stationary jets fragrance diffuser (spas with blowers only) Reservoir containing a fragrance released into the air while the blower is operational. IMPORTANT ! NEVER LEAVE AT LEAST 3 CLOSE ALL THE MASSAGE JETS IN ONE ZONE AT THE SAME TIME. JETS OPEN TO AVOID PLACING THE PUMP UNDER UNNECESSARY STRAIN THAT COULD LEAD TO DAMAGE 15/20 . 2007/06 - Version : H - code : 0037811 MAINTENANCE FILTRATION Spa water is filtered through two filter cartridges located in the skimmer body. Cartridges need to be cleaned periodically, or replaced if required. We recommend that you use two sets of filter cartridges alternately so that each set of cartridges may be cleaned properly while the other is installed in the skimmer. Periodic maintenance may be programmed using the spa pack’s electronic timer. The timer will then remind the user to clean the cartridges at the set time. (See maintenance timer configuration in the spa pack manual). The cleaning interval may vary from one spa to another depending on several criteria (indoor, outdoor installation, number of users, frequency of use, water temperature, etc.). At the outset, filter cartridges should be checked every week if the spa is installed outdoors and every 2 weeks if the spa is installed indoors. Afterwards, depending on the extent of filter clogging, the user will adapt the interval based on experience. A drop in the flow rate of the massage jets supplied by pump 1 is a typical indication that the filter cartridges are clogged and require cleaning. Fig. 1 Removal / replacement of the filter cartridges: - Stop pump 1 (filtration / massage) if it is in operation. - Holding the skimmer weir, pull the outer frame of the skimmer upwards to release and remove it (Fig. 1). - Pull out the basket sliding it horizontally towards the inside of the spa (Fig. 2). The cartridges are now visible. - Unscrew the cartridges, turning them anticlockwise (Fig. 3). Repeat the procedure in the reverse order to replace the clean cartridges. Cleaning the filter cartridges: Leave the cartridges steeping in a solution of AQUAFILTER diluted to 25% for 12 hours. Remove the cartridges and rinse them abundantly using a water jet to remove all trace of residue (do not use a high pressure water jet). Allow them to dry and then brush them gently with a hard bristle brush. Store them in a dry place for future use. Fig. 2 Fig. 3 OZONATOR The ozonator should be replaced every 3 to 4 years depending on usage. If the ozonator is not replaced, bubbles will continue to be released from the ozone return jet, but will not have an efficient ozonating action. BLOWER The blower has a service life of 3 to 4 years depending on usage. It should be replaced before this interval expires and the blower breaks down. FRAGRANCE DIFFUSER The fragrance dispenser perfumes the air expelled by the blower. A fragrance pellet will last for 30 hours of blower operation. To replace a used fragrance pellet or change the fragrance, unscrew the cap of the container on the edge of the spa. Make sure that the cover of the fragrance dispenser is screwed on correctly to ensure leaktightness. An incorrectly closed cover can allow air to escape and can allow water to penetrate into the blower causing irreparable damage. Only use the aromatherapy bars provided with the spa or sold by Procopi. Never re-impregnate a bar with essential oils. Some oils, not approved by Procopi, can have an adverse effect on plastics. ROTATING JETS The rotating jets are fitted with plastic ball bearings that are inclined to become clogged over time, preventing the rotation of the jet. To clean the rotating jets: - insert a screwdriver into one of the notches in the periphery of the rotating part. - turn the rotating jet gently until you feel the inner locking tab at the tip of the screw driver. - with one hand, push the screw driver forwards, without forcing, to release the front face and pull this with the other hand. - clean by injecting compressed air into the rear duct of the jet until it can rotate freely. - replace the jet: push it in and rotate, pushing gently until the locking “click” is heard. If water is hard (Th>20°f) and it is not treated, a calcium deposit can build up on the body of the jet and its bearing, preventing rotation of the jet or interfering with adjustment of the flow-rate by the jet face plate. 16/20 2007/06 - Version : H - code : 0037811 WATER TREATMENT Water pH: The water pH should be kept between 7.2 and 7.4 to ensure effective sterilisation and avoid damage to users’ skin. Test the pH regularly and use AQUAPLUS and AQUAMINUS to raise or lower the water pH. Correct by adding these products in small quantities to avoid swinging to the opposite extreme. Ozonator: The spa pack includes an ozonator that generates ozone from the air. Ozone is a powerful oxidising and disinfecting agent that participates in the sterilisation of the water and thus reduces the quantity and cost of sterilising chemicals required. The ozonator is slaved to spa filtration, switching on automatically during filtration periods. A dedicated jet in the base of the spa releases bubbles of ozone. The reaction time of ozone is approximately 1/10 of a second, water treatment therefore occurs in the tube and the ozone is no longer reactive once released by the jet. It is absolutely essential to maintain the correct pH and sterile conditions. Ozone complements chemical treatment but does not replace it. The ozonator has a service life of 3 to 4 years after which it should be replaced. Active oxygen (mono potassium persulphate - OXYSPA) : Caution, this should not be confused with hydrogen peroxide, another oxygenated compound, that could cause serious damage to the spa. Due to its powerful anti-microbial action and the fact it is odourless, active oxygen is the most suitable sterilising agent for spas. Dose : 20g per 1000 litres water. Add a dose once or twice a week depending on the spa’s frequency of use. The dose should be added into the skimmer basket while the filter is on, 30 minutes before entering the spa. Shock chlorination: Carry out a shock chlorination treatment of the spa every month to irradicate any trace of bacteria that could evolve to resist the treatment used and lodge in inaccessible areas (air and water circuits). Product : AQUACHOC 60 Dose : 20 g per 1000 litres water. Pour the dose into the skimmer while the filter is on. Preferably, this should be done after using the spa to allow the chlorine time to act and to be eliminated before the spa is next used. The use of hydrogen peroxide to treat water in spas is strictly and formally prohibited. This chemical could cause damage both to the shell itself and to any plastic fittings. The use of bromine is also prohibited (bromine is not compatible with PVC). NEVER POUR ANY CHEMICALS DIRECTLY INTO THE SPA SHELL. THESE SHOULD ALWAYS BE POURED OR PLACED IN THE SKIMMER TO AVOID ANY DAMAGE TO THE ACRYLIC SHELL THE THIS SPA SHOULD BE EMPTIED AND REFILLED WITH “FRESH” WATER ON A REGULAR BASIS. SHOULD BE DONE AT AN INTERVAL OF 10 TO 30 DAYS DEPENDING ON THE NUMBER OF USERS AND THE FREQUENCY OF USE. SPA VOLUMES COPACABANA 1,400 litres MOJITO PINA 1,000 litres COLADA 750 litres 17/20 MARGARITA 1,100 litres 2007/06 - Version : H - code : 0037811 THE ACRYLIC SHELL To keep the shell surface in good condition, heed the following advice: - Use standard, NON ABRASIVE household products for most cleaning. Rinse well and dry with a clean cloth. - NEVER use abrasive cleaning products. - Do not allow contact with products such as acetone (solvent), nail varnish, dry cleaning products, varnish, turpentine, etc. - Remove dust and dry dirt with a soft, damp cloth. - Use isopropyl alcohol on a soft cloth to clean grease, oil, paint and ink stains. - Do not use razor blades or any other sharp object that could scratch the surface. Small scratches may be repaired by applying a thin layer of car polish and buffing gently with a clean cloth. For deeper scratches, rub the surface lightly with 400 grit sand paper (moistened with water), finish with a fine grain sand paper (1000 or 1200) apply polish and buff to a shine. - Shell accessories (massage jet suction parts, diverting valves, air controls, fragrance diffusers, etc.) should only be cleaned with a wet sponge. - The isothermal cover is recommended for outdoor spas. This protects the acrylic shell from temperature variations between the areas above and below the water line. The shell is vacuum thermoformed, with this manufacturing process the following particularities are normal: - slight whitening of the deeper parts of the shell. - a variation of ± 6 mm in the height of the spa edge. - a slight crimping of the upper section that can occur when the polyester reinforcement is removed. - variations in the appearance of acrylic shell surface, it can be granulated or smooth. THE WOOD SURROUND The portable version of the spa features a solid red cedar surround that intimates the charm and quality of a handcrafted finish. RED CEDAR has a reputation as one of the most hard-wearing and long-lasting types of wood. Water and damp proof, 100% solid, “clear 2”, uniform colour, no knots. Density 450 Kg/m3 Slat thickness:15 mm. The wood panelling for the spas is delivered untreated. It is neither painted nor varnished in order to allow the final user choose the finish. We recommend that the wood be treated with a wood saturator designed to protect softwoods like Red Cedar. The saturator penetrates deeply into the wood and forms a layer that nourishes and protects the wood over time. The wood saturator is rich in natural raw materials, it creates a mat finish similar to that achieved with oil, thus enhancing the natural elegance of the wood. Comment: A small gap may be observed between the vertical or horizontal slats of the wood surround. Similarly, some variations may be observed in the colour. Wood is a living material that works naturally. This natural process may be accelerated if the wood surround is subject to significant variations in temperature or humidity. 18/20 2007/06 - Version : H - code : 0037811 ISOTHERMAL COVER We recommend that the isothermal cover be kept on the spa while it is not in use. The cover fulfils several functions: - prevents heat loss, generating energy savings - reduces the quantities of chemicals required - prevents pollution - ensures the safety of young children - protects the acrylic shell Covers are UV treated. They should only be cleaned with water or soapy water. Do not use any other cleaning products. Each cover comes with lockable clips. Installing the cover: After unfolding the cover and placing it on the spa, screw the fasteners to the edge (the screws and the key are provided in a sachet enclosed with the cover). 19/20 2007/06 - Version : H - code : 0037811 LIMITED GUARANTEE The spas belonging to the SPAFRANCE range are protected by a limited guarantee. This guarantee only extends to the original purchaser of the spa. Guarantee coverage: 5 years against any flaw in the shell or shell surface – The spa shell is guaranteed against leaks attributable to a structural defect for a period of five (5) years as of the initial date of purchase of the spa. The acrylic surface of the spa is guaranteed against blistering, cracking and delamination caused by a manufacturing or material defect for a period of five (5) years as of the initial date of purchase of the spa. 2 years against defective component and plumbing – The spa pack components and plumbing components installed during manufacture are guaranteed for a period of two (2) years as of the first date of purchase of the spa. Installation of the spa pack at more than 7.5 m from the spa, or use of cables or extensions other than those provided to remotely install the spa pack will entail cancellation of the guarantee. Cover The cover is guaranteed for a period of two (2) years as of the initial date of purchase of the spa. Deformation caused by excess loads on the cover are not covered by the guarantee. Wood surround The portable spa surround is made of solid Red Cedar. Wood is a living substance, consequently it is entirely normal to observe variations in the colour of the slats. Depending on its environment wood can work; the wood surround is therefore not covered by a guarantee. GUARANTEE LIMITATIONS The owner of the spa will be held entirely responsible for any repairs to the spa carried out by a person other than an accredited representative of SpaFrance. Any modification, incorrect maintenance or inappropriate use of the spa, or any repair performed by a person other than an accredited representative of SPAFRANCE, will result in the immediate cancellation of this guarantee. Specifically: damage caused by operating the spa at a temperature outside the range 1°C to 42°C, operating the spa below 230V or above 240V, damage due to clogged or dirty filters, damage resulting from the absence of the rigid cover, damage caused by using chemically unbalanced water or water with an unsuitable pH. Do not leave the spa in direct sunlight while it is empty, this can lead to overheating of the acrylic surface and subsequent delamination or blistering. Certificate of Compliance These Spas comply with the stipulations set out in NF EN 60335-1 and NF EN 60335-2-60 PLC with a share capital of €7,000,000 Register of commerce Rennes B 333263846000 37 20/20 2007/06 - Version : H - code : 0037811