Plasmacluster protects
Transcription
Plasmacluster protects
Cassette Type Air Conditioner Sharp’s NEW cassette type air conditioner, ideal for office and home Its innovative design fits perfectly to your preferred enviconment giving you the utmost cooling comfort. Plasmacluster protects you and your family... The washable filter can be cleaned easily. It ensures that routine maintenance is kept to the simplest steps. The highly durable motor protects and prolongs the lifespan of the air conditioner. Indulge into a soothing environment with cool air that is discharged quietly and circulated evenly. Call us! Ask us! Consult us! 1800-888-678 www.sharp.com.my/A-Force Plasmacluster...Only From SHARP SHARP-ROXY SALES & SERVICE COMPANY (M) SDN.BHD. (8394-W) Its innovative compact design fits perfectly to your home or office giving you a lovely cooling environment. Sharp’s cassette type air conditioner is easy to maintain, providing cool environment without a fuss. The child lock function prevents from tempering the settings unnecessarily. www.sharp.com.my HEAD OFFICE: No.1A, Persiaran Kuala Langat, Section 27, 40400 Shah Alam, Selangor Darul Ehsan Product Enquiry Tel: 03-5102 5369 Service Enquiry Tel: 1800 888 678 (Toll Free) Fax: 03-51025329 E-mail [email protected] BRANCH OFFICE: • PULAU PINANG No.76-2, Persiaran Bayan Indah, Sungei Nibong, 11900 Penang Tel: 04-644 3642 (Pilot Line) Fax:04-645 2677 • IPOH No.37B, Medan ipoh 1A, Medan Ipoh Bistari, 31400 Ipoh, Perak. Tel: 05-546 0846 / 547 0984 Fax: 05-546 5929 • JOHOR BAHRU No.39, 39A, Jalan Molek 2/4, Taman Molek, 81100 Johor Bahru Tel: 07-353 6066 / 353 6067 Fax: 07-353 6071 • KUANTAN No.A75, Tingkat 1, Jalan Air Putih, 25300 Kuantan, Pahang Darul Makmur Tel: 09-566 1055 / 566 1431 Fax: 09-566 5435 • MALACCA No.387 & 387A, Taman Peringgit Jaya, 75400 Malacca Tel: 06-283 6540 / 282 7753 Fax: 06-283 6527 • KUCHING No.30, Jalan Penrissen, 5th Mile, Hakka Avenue Estate, 93250 Kuching, Sarawak Tel: 082-450 281 / 450 282 / 450 297 Fax: 082-450 276 (Office), 082-450 279 (Service) • KOTA KINABALU Lot 17, Ground Floor & loT 16, 1ST Floor, Millennium Centre, Jalan Millinnium, 88200 Kota Kinabalu, Sabah. Tel: 088-211 616 / 211 612/ 211 613 Fax: 088-211 619 (Office) 088-211 615 (Service) • KOTA BHARU No.4706-D, Jalan Long Yunus, Taman Maju, 15200 Kota Bharu, Kelantan Tel: 09-743 2572 Fax: 09-746 1716 Air Conditioners 2014 Feature Descriptions: Split Type Laundry Function To dry and deodorize hanging clothes inside the house with Poweful jet and HD7000PCI. Nature Wing The Nature Wing fan design is modeled after nature and creates a more efficient airflow that results in energy-saving operation (in both indoor and outdoor units). Inverter Controlled Operation This function features a quick cooling operation and decreases fluctuation in temperature and reduces power consumpton. Super Jet Super Jet delivers powerful cool air downward and cools the room and your body quickly. FULL POWER TURBO Full Power Mode In this operation, the air conditioner works at the maximum power to rapidly cool the room. Turbo Operation In this operation, the air conditioner works at “Extr-high” speed to cool the room quickly. Powerful Jet Realizing A Harmony Of Energy Savings And Convenience Room temp. Inverter Technology Non-inverter type Inverter type Air Conditioner operation is controlled to achieve a considerable reduction in power consumption, maintaining a pleasant room temperature. While inverter air conditioners have a full-output operation mode, they drastically reduce energy consumption when used in energy-saving operation mode. The inverter circuitry modifies and maintains room temperature by switching the compressor between high and low operation modes, instead of switching it on and off completely as non-inverter models do. The inverter model keeps the compressor running and simply reduces output when the room reaches the desired temperature, enabling comfortable, even temperature control. Even temperature control Set temperature Time High-power operation Energy-saving operation Operation In this operation, the air conditioner delivers incredibly strong and cool air to cool the room instantly. Baby Sleep Mode Gentle, healthy cooling for delicate people such as babies and mothers-to-be. Comfort Mode keeps you cool and comfortable Comfort Mode Cooling comfort is enhanced by suppressing temperature variations and humidity increases. Gentle Cool Air System Energy-saving design dramatically reduces the electric bill Low Wattage Type The "Comfort Eco" Series is designed to raise energy efficiency, and greatly reduces power consumption compared to conventional air conditioners, even though it is not an inverter type. This function provides cold air traveling up the ceiling during cooling operation in order to avoid direct airflow. Highly efficient evaporators and condensers enable these models to operate with greater energy efficiency. Lower Room Temperature Setting (from 16˚C) Power consumption (9,000 BTU) In cooling operation, room temperature can be set from 16˚C. Electric bill 24% down* Computerized Dry Mode Operation The indoor fan motor and the compressor are controlled by the microcomputer to maintain room humidity without dropping the room temperature. Auto Operation Mode In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature. 900 w 690 w Nomal AC Comfort Eco Auto & 3-Step Fan Speed Settings Auto fan speed and 3-step (HIGH/LOW/SOFT) manual fan speed are available. Auto Restart Function Control Convenience Microcomputer Control LCD Wireless Remote Control Nomal Mode Comfort Mode Nomal Mode “Awakening” Function ON ON OFF “Auto Sleep” Function ON OFF ON ON OFF ON ON OFF OFF OFF Comfort Mode When the OFF Timer is set, the temperature setting is automatically adjusted to prevent the room from becoming excessively hot or cold while you sleep. Gentle, healthy cooling for delicate people such as babies and mothers-to-be. 13.0 12.3 Conventional air conditioners sometimes stop cooling (switch the compressor OFF) for long periods of time to adjust the temperature. This was a cause for discomfort, but with the new control software, the OFF time is significantly reduced to achieve finer cooling comfort. When the ON Timer is set, the unit will turn on prior to the set time to allow the room to reach the desired temperature by the programmed time. Sleep Mode EER 690 W 900 W Comfort 2 The "Comfort Eco" Series is equipped with precise fan control software and new temperature control software to reduce the temperature variation that causes discomfort in conventional air conditioners. 12-Hour ON/OFF Timer SLEEP MODE Power Consumption * Compared to our products. Comfort 1 When power failure occurs and after power recovery, the unit will automatically restart in the same setting which was active before the power failure. Capacity 9,000 BTU 12,000 BTU Temperature variation is reduced by 20%. OFF time is reduced by 30%. Air Quality Auto Swing Louver (UP/DOWN) Automatic vertical airflow is available in order to make the room uniformly cool. High-Density Plasmacluster Ions Easy Clean Mesh Filter Dust is easily removed for simple cleaning. Anti-Mold, Detachable & Washable Air Filter All-Aluminum Heat Exchanger Additional Features The All-Aluminum Heat Exchanger supports durability for long, reliable use High-Density Plasmacluster Ions clean the room air powerfully and quickly. Plasmacluster technology is Sharp’s original air purifying technology that removes suspended airborne mold and viruses. Resistant to corrosion and highly durable prevent tube corrosion and fridgerant leakage. Quiet Operation Self Cleaning Function SELF CLEAN operation provides the effect of reducing the growth of mold fungus, and dries the inside of the air conditioner unit with Plasmacluster Ions. Dual Drain Setting Rightward and Leftward Drain hose setting is available for easy installation. LED Display On Front Panel Scan here for more information The "Comfort Eco" Series uses an all-aluminum heat exchanger that dramatically reduces the loss in efficiency caused by rust. This saves energy and reduces cost. Advantages of the All-Aluminum Heat Exchanger Volume of refrigerant reduced by approx. 50% Weight reduced by 40% Sorting before recycling is unnecessary 1. Cost-Saving Design Higher energy efficiency reduces cost. Comparison of Accelerated Test* Results All-aluminum Copper-aluminum 2. Space-Saving Design Smaller and lighter design saves space. 3. Long-Life Design Higher durability extends the lifetime. 0 hours 2000 hours The fins are damaged by rust. 0 hours 2000 hours Degradation of the fins is extremely low, so high efficiency is maintained and energy is saved. * Accelerated salt spray test (SST) conditions: JIS Z 2371. Live Comfortably. Stay Cool. Save Energy. Inverter Plasmacluster Single Type Wall Mounted I AHXP10/13NRV 5 Model AHXP10NRV AHXP13NRV Outdoor unit AHXP13NRV AUX13NV Capacity *1 Cool 2.80 3.60 Cool COP Cool Power input Dimensions (WXHXD) AHXP18MV AHXP24MV Outdoor Outdoor unit Model Indoor Capacity *1 Cool Power input COP Sound pressure level *2 AU-X24MV Dimensions (WXHXD) mm Indoor Pipe diameter Liquid side inch Gas side inch 920 X 290 X 240 920 X 290 X 240 598X 495X 265 730 X 540 X 250 (Min.-Max.) New 5 Produk ini Menggunakan 25.21% Kurang Tenaga Daripada Produk Biasa This product consume 25.21% Less Energy Than An Average Product kW 9 Capacity *1 Cool 2.64 3.50 5.00 6.00 1/4 1/4 Power supply 1-15 1-15 Cool Dry 7 7 Model 28 1/2 ˚C 7.5 R410A 21–43 *1 Rating conditions Inside air temperature: Outside air temperature: 27˚C D.B. 19˚C W.B. 35˚C D.B. 24˚C W.B. *2 Sound pressure level is measured according to JIS C 9612. AUX24MV 6.25 (1.70-7.10) 220-240-1ø-50 198–264 7.0 A dB 44 45 m3/min 15.2 Indoor Outdoor 53 dB mm mm Indoor Pipe diameter 1050 X 313 X 250 1050 X 313 X 250 780 X 540 X 269 850 X 710 X 330 12 35 Cooling Operation Capacity COP kW (Min.-Max.) 3.38 2.64 (0.90–2.73) 3.30 3.50 (0.90–3.60) 3.33 5.00 (1.60–5.50) 3.16 6.00 (1.70–6.80) Outdoor unit 4 Specifications Indoor Outdoor Cool Voltage range Running current Power input Outdoor unit COP Cool Cool Cool (WXHXD) Indoor Outdoor A W m3/min 1/4 1/4 1-15 1-15 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2868/14 AHAP9RHV AHAP12RHV AUA9RHV AUA12RHV 2.64 3.50 m 10 10 7.5 m ˚C Sound pressure Indoor (Hi) level *2 AU-X9NEV 3.61-3.54 8.6 10.6 R410A (WXHXD) Penyaman Udara Model Indoor Capacity *1 Cool Power supply 3 Outdoor 730 X 540 X 250 Running current AHAP18MMV AHAP24MMV Power input COP Sound pressure level *2 Cool Cool Cool Indoor (Hi) Outdoor Airflow volume (Cool/Indoor) Dimensions (WXHXD) AU-A18MMV AU-A24MMV kW V-ph-Hz Indoor Outdoor A W dB dB m3/min mm mm SHARP AH-XP18MV-1 Penyaman Udara 2 2014 Outdoor W mm Produk ini Menggunakan 26.37% Kurang Tenaga Daripada Produk Biasa This product consume 26.37% Less Energy Than An Average Product MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2872/14 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number :2870/14 AHAP24MMV AUA18MMV AUA24MMV 5.01 6.70 220-240-1ø-50 8.2-7.8 1740-1790 2.88 46 53 16.0 Maximum height difference m 39 44 45 47 8.7 53 10.8 Maximum chargeless length Refrigerant Operating range Cool (Outdoor) 54 15.2 Liquid side inch Gas side inch 3.16 38 15.6 *1 Rating conditions 920 X 290 X 240 920 X 290 X 240 965 X 313 X 250 965 X 313 X 250 598 X 495 X 265 730 X 540 X 250 780 X 540 X 269 850 X 710 X 330 AHX12NEV AHX18MEV AHX24MEV AUX9NEV AUX12NEV AUX18MEV AUX24MEV 8 9 11.5 11.5 1/4 1/4 1/4 1/4 1-15 1-15 1-15 1-15 7 7 10 10 kg m 1900 3.33 Outdoor Min-Max pipe length 1500 3.30 Single Type m 22 3/8 7.5 28 35 1/2 50 1/2 7.5 5/8 7.5 7.5 R410A ˚C 21–43 Inside air temperature: 27˚C D.B. 19˚C W.B. Outside air temperature: 35˚C D.B. 24˚C W.B. *2 Sound pressure level is measured according to JIS C 9612. Penyaman Udara Model Indoor Capacity *1 Cool AHA9RDV AHA12RDV AHA12RDV AHA12RDV 3.83 3.61 Cool A 3.2-3.1 W Cool 690-710 mm Model Indoor Net weight Indoor Pipe diameter Liquid side inch Gas side inch Outdoor Outdoor Min-Max pipe length AHA12RDV 9 10 1/4 1/4 1-10 1-15 24 28 3/8 1/2 7.5 m Refrigerant Operating range (Outdoor)Cool *1 Rating conditions AHA12RDV AHA9RDV kg m Maximum height difference 598 X 495 X 265 730 X 540 X 250 AHA9RDV kg m Maximum chargeless length 38 8.6 9 877 X 292 X 222 mm Outdoor 4.5-4.3 1290 3.83-3.72 m3/min Airflow volume (Cool/Indoor) Indoor Dimensions (WXHXD) 220-240-1ø-50 198–264 Standard 2014 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2869/14 V I SHARP AH-X9NEV-1 4 Produk ini Menggunakan 14.13% Kurang Tenaga Daripada Produk Biasa This product consume 14.13% Less Energy Than An Average Product MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2869/14 AHA9RDV kW Cool Penyaman Udara 2014 Produk ini Menggunakan 14.13% Kurang Tenaga Daripada Produk Biasa This product consume 14.13% Less Energy Than An Average Product AHA9RDV V-ph-Hz COP Outdoor unit SHARP AH-X9NEV-1 4 Outdoor Power input Cooling Operation Capacity COP kW BTU/h 3.83 9,000 3.83-3.72 3.61 12,000 3.61-3.54 Wall Mounted I Specifications Voltage range Model 7.5 5 R22 ˚C 7 21–43 Inside air temperature: 27˚C D.B. 19˚C W.B. Outside air temperature: 35˚C D.B. 24˚C W.B. AUA12RDV Outdoor Indoor Outdoor kg kg m Maximum chargeless length Maximum height difference m Operating range (Outdoor) Cool ˚C *1 Rating conditions AUA9RHV AUA12RHV 9 10 Model Indoor 1/4 1/4 Capacity *1 Cool 1/2 1-10 1-15 5 7 7.5 R22 Inside air temperature: 27˚C D.B. 19˚C W.B. Outdoor Outside air temperature: 35˚C D.B. 24˚C W.B. Cool Dry Model AHA18MEV AHA24MEV Cooling Operation Capacity kW BTU/h COP 5.01 6.70 17100 22900 Outdoor unit 2.88 2.79 Cool W Sound pressure Indoor (Hi) dB COP Cool level *2 Outdoor AHA9/12/18/24PCV Model Indoor Net weight Indoor Pipe diameter 11.5-11.3 2400-2500 Min-Max pipe length Outdoor Maximum chargeless length 54 Refrigerant 46 Maximum height difference 16.0 Operating range (Outdoor) 780 X 540 X 269 850 X 710 X 330 *1 Rating conditions kg kg Liquid side inch Gas side inch 2.79 1050 X 313 X 250 1050 X 313 X 250 AHAP18MMV AHAP24MMV Outdoor m m m Cool ˚C AUA18MMV AUA24MMV 12 12 35 R22 10 21–43 Inside air temperature: Outside air temperature: 27˚C D.B. 19˚C W.B. 35˚C D.B. 24˚C W.B. *2 Sound pressure level is measured according to JIS C 9612. Model Indoor Capacity *1 Cool Power input 7.5 Cool Dry Model AHA9PCV AHA12PCV AHA18PCV AHA24PCV Cooling Operation Capacity kW BTU/h COP 2.7 2.5 8700 2.73 3.5 12000 2.79 5.3 18000 2.81 6.4 21,800 Outdoor unit kW V-ph-Hz 220-240-1ø-50 8.2-7.8 198–264 11.5-11.3 1740-1790 2400-2500 46 44 2.88 2.79 53 54 16.0 mm 16.0 965 X 313 X 250 1050 X 313 X 250 mm 2 SHARP AH-XP24MV-1 Produk ini Menggunakan 26.37% Kurang Tenaga Daripada Produk Biasa This product consume 26.37% Less Energy Than An Average Product MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number :2870/14 780 X 540 X 269 850 X 710 X 330 2.5 3.5 48 52 Dimensions Indoor mm Airflow volume (Cool/Indoor) m3/min mm 2014 Penyaman Udara 3 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2872/14 925 39 8 5.3 Indoor Net weight Indoor Pipe diameter Liquid side inch Gas side inch Outdoor Outdoor Min-Max pipe length kg kg m m Maximum chargeless length AHA18MEV AHA24MEV AUA18MEV AUA24MEV 11.5 11.5 1/4 1/4 1-15 1-15 35 1/2 Refrigerant Operating range (Outdoor)Cool 5/8 7.5 m Maximum height difference 52 7.5 10 R22 ˚C 10 21–43 *1 Rating conditions Inside air temperature: Outside air temperature: 27˚C D.B. 19˚C W.B. 35˚C D.B. 24˚C W.B. *2 Sound pressure level is measured according to JIS C 9612. 2014 6.4 Model AHA9PCV AHA12PCV AHA18PCV AHA24PCV Indoor AHA9PCV AHA12PCV AHA18PCV AHA24PCV Outdoor Net weight Indoor Outdoor kg kg Liquid side inch Gas side inch 9 10 13 15.5 1/4 1/4 1/4 1/4 25 35 45 51 8.81 10.56 Pipe diameter 9.52 9.59 Min-Max pipe length m 1-15 1-15 1-20 1-20 Maximum height difference m 3 5 10 10 822 1250 38 47 9 Model SHARP AH-XP18MV-1 Produk ini Menggunakan 25.21% Kurang Tenaga Daripada Produk Biasa This product consume 25.21% Less Energy Than An Average Product 220-240-1ø-50 9.60 dB SHARP AH-XP18MV-1 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2872/14 AHA12PCV AHA18PCV AHA24PCV 10.58 dB 3 Produk ini Menggunakan 25.21% Kurang Tenaga Daripada Produk Biasa This product consume 25.21% Less Energy Than An Average Product AHA12PCV AHA18PCV AHA24PCV (btu/h)/w Outdoor Penyaman Udara AHA9PCV 5.80 W 2014 AHA9PCV 3.65 level *2 Outdoor Penyaman Udara A Cool Sound pressure Indoor (Hi) 2014 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2872/14 Outdoor Cool SHARP AH-XP18MV-1 Produk ini Menggunakan 25.21% Kurang Tenaga Daripada Produk Biasa This product consume 25.21% Less Energy Than An Average Product EER (WXHXD) AH-A9/12PCV AH-A18/24PCV 3 Specifications Running current Cool 1-15 7.5 Penyaman Udara Power supply 5/8 1-15 10 New 1/4 1/2 6.70 AU-A24MEV 53 1/4 5.01 m3/min Outdoor 2014 AUA24MEV dB Airflow volume (Cool/Indoor) Indoor Dimensions SHARP AH-XP24MV-1 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number :2870/14 AHA24MEV A Power input 2 Produk ini Menggunakan 26.37% Kurang Tenaga Daripada Produk Biasa This product consume 26.37% Less Energy Than An Average Product V Cool Running current Penyaman Udara 2014 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2872/14 AUA18MEV V-ph-Hz Voltage range SHARP AH-XP18MV-1 Produk ini Menggunakan 25.21% Kurang Tenaga Daripada Produk Biasa This product consume 25.21% Less Energy Than An Average Product AHA18MEV kW Power supply 7.5 21–43 3 Specifications 28 3/8 m Penyaman Udara AHAP12RHV 24 Liquid side inch inch Gas side AHA18/24MEV AHAP9RHV 2014 AHAP18MMV 198–264 Pipe diameter AHX9NEV kg Indoor 9.0 1060 46 dB 7.2 780 3.38 dB mm Net weight (1.70-6.80) 220-240-1ø-50 Power supply SHARP AH-XP24MV-1 Produk ini Menggunakan 25.21% Kurang Tenaga Daripada Produk Biasa This product consume 25.21% Less Energy Than An Average Product V Voltage range Outdoor unit Indoor Outdoor 198–264 A (WXHXD) Specifications Cooling Operation Capacity COP kW BTU/h 2.88 5.01 17100 2.79 6.70 22900 Outdoor New AHA9/12RDV Cool Dry AUA12RHV AHAP18/24MMV Model 5.5 (1.60-5.50) Indoor AU-X24MEV Standard Model AU-A18MEV Cool Dry 3.8 V Airflow volume (Cool/Indoor) m3/min Dimensions (0.90-3.60) Running current Deluxe I Refrigerant 877 X 292 X 222 598 X 495 X 265 AU-X12NEV 21–43 Indoor Min-Max pipe length 970-990 3.83-3.72 Model Pipe diameter 4.5-4.3 690-710 Cool 7.5 *1 Rating conditions Inside air temperature: Outside air temperature: 27˚C D.B. 19˚C W.B. 35˚C D.B. 24˚C W.B. *2 Sound pressure level is measured according to JIS C 9612. Net weight 220-240-1ø-50 198-264 3.2-3.1 Cool 5/8 2014 Produk ini Menggunakan 11.86% Kurang Tenaga Daripada Produk Biasa This product consume 11.86% Less Energy Than An Average Product MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2869/14 mm mm 4 2014 COP (0.90-2.73) Model SHARP AH-X12NEV-1 Produk ini Menggunakan 14.13% Kurang Tenaga Daripada Produk Biasa This product consume 14.13% Less Energy Than An Average Product V Airflow volume (Cool/Indoor) Dimensions kW V-ph-Hz Penyaman Udara SHARP AH-X9NEV-1 Power input kW V-ph-Hz Running current Cool 50 1/2 m Wall Mounted I 12 Liquid side inch Gas side inch Refrigerant Operating range (Outdoor)Cool 54 AUX24MV kg Maximum chargeless length 15.6 AHXP24MV AUX18MV kg Outdoor Maximum height difference Indoor (Hi) Outdoor Net weight AHXP18MV Outdoor 3.32 1880 3.66 Indoor Min-Max pipe length 1440 Cool Model 8.9 W (Min.-Max.) Voltage range AHX9NEV AHX12NEV AHX18MEV AHX24MEV 2014 AUX18MV V 2014 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2858/14 AUX24MEV Outdoor Standard SHARP AH-X24MEV-1 Produk ini Menggunakan 27.04% Kurang Tenaga Daripada Produk Biasa This product consume 27.04% Less Energy Than An Average Product AHX24MEV MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number :2870/14 5.27 5 I SHARP AH-XP24MV-1 AHXP24MV (1.60-6.00) Penyaman Udara 2014 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2846/14 AUX18MEV Produk ini Menggunakan 26.37% Kurang Tenaga Daripada Produk Biasa This product consume 26.37% Less Energy Than An Average Product MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2872/14 Cool Power supply AUA9RHV Penyaman Udara 2014 AHXP18MV V-ph-Hz Cool SHARP AH-XP18MV-1 5 SHARP AH-X18MEV-1 5 Produk ini Menggunakan 22.12% Kurang Tenaga Daripada Produk Biasa This product consume 22.12% Less Energy Than An Average Product AHX18MEV 7.5 m Penyaman Udara 2014 AUX12NEV 3/8 m SHARP AH-X12NEV-1 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2868/14 AHX12NEV 22 m 4 Produk ini Menggunakan 11.86% Kurang Tenaga Daripada Produk Biasa This product consume 11.86% Less Energy Than An Average Product AUX9NEV 8 kg Outdoor Penyaman Udara 2014 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2869/14 AHX9NEV AUX13NV kg SHARP AH-X9NEV-1 Produk ini Menggunakan 14.13% Kurang Tenaga Daripada Produk Biasa This product consume 14.13% Less Energy Than An Average Product Indoor AHXP13NRV AUX10NV AUA9RDV Capacity *1 AHAP9RHV AHAP12RHV mm Net weight Refrigerant Operating range (Outdoor)Cool 47 4 Wall Mounted I Model AHXP10NRV Outdoor Maximum chargeless length 10.8 Penyaman Udara Model Model 8.7 Single Type Plasmacluster Cooling Operation Capacity COP kW BTU/h 2.64 9,000 3.83-3.72 3.50 12,000 3.61-3.54 m3/min Outdoor Airflow volume (Cool/Indoor) AU-X18MV Cool Dry 39 Specifications Running current AHAP9/12RHV Indoor Indoor Maximum height difference 38 46 Model 3.13 dB Penyaman Udara Specifications Min-Max pipe length 1150 dB AHX9/12NEV I AHX18/24MEV 6.10 890 3.15 Single Type AU-X18MEV Voltage range Model Indoor (Hi) Outdoor 198–264 4.3 A W (0.90–4.00) 220-240-1ø-50 Penyaman Udara Power supply Cooling Operation Capacity COP kW (Min.-Max.) 3.66 5.27 (1.60–6.00) 6.25 (1.70–7.10) 3.32 (0.90–3.10) V Cool Airflow volume (Cool/Indoor) AU-X13NV kW V-ph-Hz Running current level *2 AHXP18/24MV Cool Dry (Min.-Max.) Inverter 2014 AUX10NV Outdoor Super Deluxe SHARP AH-XP13NRV-1 MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2871/14 AHXP10NRV Sound pressure AU-X10NV 5 Produk ini Menggunakan 16.23% Kurang Tenaga Daripada Produk Biasa This product consume 16.23% Less Energy Than An Average Product MS ISO5151 , 2004 No. Kelulusan COA/COA Approval Number : 2873/14 Indoor Voltage range Cooling Operation Capacity COP kW (Min.-Max.) 3.15 2.80 (0.90–3.10) 3.60 (0.90–4.20) 3.13 Penyaman Udara 2014 Produk ini Menggunakan 19.84% Kurang Tenaga Daripada Produk Biasa This product consume 19.84% Less Energy Than An Average Product Model Power supply Cool Dry SHARP AH-XP10NRV-1 Penyaman Udara Specifications I 56 14 2277 48 Maximum chargeless length m 14 Refrigerant Operating range Cool (Outdoor) ˚C 56 790 X 265 X 170 845 X 275 X 180 940 X 200 X 298 1007 X 219 X 315 720X 428 X 320 845X 540 X 320 848 X 540 X 320 955 X 700 X 396 3/8 - 1/2 1/2 - - R22 18–43 *1 Rating conditions Inside air temperature: Outside air temperature: 27˚C D.B. 19˚C W.B. 35˚C D.B. 24˚C W.B. *2 Sound pressure level is measured according to JIS C 9612. 5/8 - Plasmacluster Technology Purifies Air With The Same Ions As In Nature INVERTER PLASMACLUSTER INVERTER NON-INVERTER AHXP10/13NRV AHXP18/24MV AHX9/12NEV AHX18/24MEV AHAP9/12RHV AHAP18/24MMV AHA9/12RDV AHA18/24MEV AH-A9/12/18/24PCV Plasmacluster mechanism to remove microbes O 2– Type Hydroxide (OH) radical O 2– H+ H2O H+ Hydroxide (OH) radical (Indoor) Hydrogen (H) Hydrogen (H) (Indoor) (Indoor) Ions are released The ions act on airborne microbes Plasmacluster ions, the same positive and negative ions found in nature, are generated by plasma discharge and released into the air. The ions form hydroxide (OH) radicals that are highly oxidizing only when they adhere to the surfaces of mold and viruses. They instantly remove the hydrogen from the surface proteins, breaking them down. The broken-down components return to the air as water The hydroxide (OH) radicals combine with hydrogen (H) to form water (H 2O), which returns to the air. Panel Power Supply 99.7 Reduces % of airborne viruses With Plasmacluster Ions 0 1% 50% 100% OOUTDOOR UNIT • Test method: A Plasmacluster Ion generator is placed in a 1 m3 box. Airborne viruses are suspended in the air inside the box followed by the release of Plasmacluster Ions. • Reduction method: Generate Plasmacluster Ions in the air. • This test was performed by the Kitasato Institute Medical Center Hospital and Kitasato Research Center of Environmental Sciences in Japan. • Test Report No.: 00313 GUA24PVC AZ-A24PCV AZ-A24PCV AZ-A24PCV 12.80 10.00 7.00 Btu/h 43670 34120 23880 W/W 2.56 2.29 2.75 380-415-50-3 220-240-50-1 220-240-50-1 kW 5.000 4.360 2.550 Rated Input Cooling kW 7.000 5.820 3.500 Sound Pressure Level (H/M/L)* dB (A) 63/–/– 60/–/– 59/–/– Sound Power Level (H/M/L)* dB (A) 73/–/– 70/–/– 69/–/– Outline (WxDxH) mm 1032x412x1250 1018x412x840 1018x412x695 Package (LxWxH) mm 1113x453x1400 1103x453x1000 1103x453x770 Net/Gross kg Outdoor Unit Dimension Without Plasmacluster Ions (Spontaneous attenuation) 60 40 With Plasmacluster Ions 20 Fan Motor 45 (min.) • Mode of operation: Plasmacluster Ion generator single operation in an experimental room of approximately 13.0 square meters. • Temperature inside the room: 21˚C, Humidity: 53% RH. • Measurement method: Air samples measuring the quantity of mold were taken from the center of the room. • Reduction method: Without a , generate Plasmacluster Ions in the air. • Test performed by the Ishikawa Health Service Association in Japan. • Test Report No.: 1503691 INDOOR UNIT Powerful Jet mode delivers a powerful blast of cool air. This mode is recommended for quick cooling after being in hot and humid conditions, or after exercising or other activities. Powerful Jet is for occasions when a direct flow of cool air is desired. 15600 11700 7550 Power Input W 4590 3750 2380 Locked Rotor Amp A 62.7 112 60 Drive Type – Direct Direct Direct Power Output PH 0.123 0.123 0.123 Power Supply v-Hz-Ph 220-240-50-1 220-240-50-1 220-240-50-1 kW 0.155 0.155 0.11 V 198/264 198/264 198/264 Power Cord Spec mm2xpcs 1.0x3 1.0x3 1.0x3 A 3.15 3.15 3.15 Sound Pressure Level (H/M/L)* dB (A) 53/51/48 53/51/48 47/45/43 Sound Power Level (H/M/L)* dB (A) 63/61/58 63/61/58 57/55/53 CFM 977/924/883 977/924/883 694/636/589 m3/h 1660/1570/1500 1660/1570/1500 1180/1080/1000 Outline Dimension (WxDxH) mm 840x840x320 840x840x320 840x840x240 Package Dimension (WxDxH) mm 963x963x409 963x963x409 963x963x325 Net Weight kg 32 32 27 Gross Weight kg 43 36 36 Outline Dimension (WxDxH) mm 950x950x60 950x950x60 950x950x60 Package Dimension (WxDxH) mm 1028x1043x130 1028x1043x130 1028x1043x130 Net Weight kg 6.5 6.5 6.5 Gross Weight kg 10 10 10 Liquid Pipe Inch 0.5 0.375 0.5 Gas Pipe Cooling Air Flow Volume (rated EXP) Weight PANEL Panel Dimension (AHAP24MEV) Gentle Cool Air Outer Diameter CONNECTION PIPE All-embracing airflow from the ceiling to the walls. 63/67 Constant Speed Rotary Min/Max Voltage Dimension (AHAP24MMV) 95/100 Constant Speed Scroll W Fuse (A) Powerful Jet mode gives you one-button cooling 105/114 Constant Speed Scroll Capacity Power Input 1 Electrical Data The number in this technology mark indicates the approximate number of ions supplied into air of 1 cm3 of air, which is measured near the center of a room (1.5 m above the floor) at the maximum wind volume, when an air conditioner using the high-density Plasmacluster Ion generating device is placed in a room with the applicable floor area. This product is equipped with a device corresponding to this capacity. Cool air spreads throughout the room, creating a pleasant environment for everyone. Its indirect breeze makes this mode ideal for use when pregnant women, the elderly, and others who may be sensitive to low temperatures are present. The soft flow of air also makes it easy to sleep. GUA36PVC V-Hz-Ph Compressor 80 30 GUA48PVC kW Type 100 15 GXA24PCV Cooling Effects on airborne mold spores 0 GXA36PCV Power Input Electrical Data Residual rate (%) Without Plasmacluster Ions Cooling EER Effective against airborne viruses and mold spores 100 % GXA48PCV Outdoor The air inside ordinary houses contains invisible, harmful organisms such as bacteria and viruses. Plasmacluster technology uses the actions of positive and negative ions to clean up these airborne contaminants and create pleasant living spaces. Residual rate Cassette Model Plasmacluster Ions purify the air to reduce contaminants and odors Effects on airborne viruses Cassette H2O Total Capacity The actual reduction rate may differ according to room conditions and the model in use. Cassette Indoor (Indoor) Protein Protein *Verified in Sharp test comparisons of ions not surrounded by water molecules. Scan here for more information Technical Specifications: Cassette Type Max Distance Inch 0.75 0.625 0.75 Height m 30 15 30 Length m 50 30 50 Note: 1. The cooling stated above is measured under following conditions: Indoor Condition: 27ºC (81ºF) DB/19ºC(66.6ºF)WB; Outdoor Condition: 35ºC(95.4ºF) DB/24ºC (75.6ºF) WB. 2. Noise is tested in the semi-anechoic room, so it should be slightly higher in the actual Operation due to enviromental change. 3. “1” is tested under standard condition.“2” is tested under rated condition according to CE/Eurovent standard. 4. *Fan different speed. * Design and specifications are current as of April 2014, but are subject to change without prior notice. * Actual colors may differ slightly from colors in this catalog. * Design and Specification are current as of April 2014, but subjet to change without prior notice. * Actualcolours may differ slightly in this catalogue.
Similar documents
Products Catalogue in PDF
The noise level reaches as low as 21 dB(A), which is 3-6 dB(A) lower than conventional air
More information