Plasmacluster Ion Generator Sales of Products Equipped with Sharp’s Plasmacluster Ion Technology Has Reached * Worldwide Powerfully Inactivate Airborne Substances High Density Plasmacluster Technology Incorporated Design and specifications subject to change without notice. Sharp is a registered trademark of Sharp Corporation. All other trademarks and registered trademarks are property of their respective holders. SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road East, Mississauga, Ontario L4Z 1W9 (905) 890-2100 • www.sharp.ca ©2009 Sharp Electronics of Canada Ltd. Printed in Canada. M6442 Airborne molds and allergens are problems the more crowded a place is. Plasmacluster technology There are many hazardous substances around us that are invisible to the eye. Air quality has become an issue in places where people Plasma discharge generates and emits the same positive and negative ions that occur in nature. Plasmacluster technology is Sharp’s original air disinfecting technology that inactivates suspended airborne mold and viruses. gather such as offices, stores, hotels, schools, hospitals and so forth. The airborne molds, viruses and allergens that permeate these places are a major cause of discomfort to guests and people who work there. Because of these times, Sharp developed proprietary Plasmacluster technology that powerfully inactivates harmful airborne substances that permeate indoor air environments. Winner of the Invention Prize at the 2008 National Invention Awards Ceremony held by the Japan Institute of Invention and Innovation (JIII) What Sharp hopes for is to contribute in whatever way it can to making business environments healthier and more comfortable. Patented by Sharp (patent No. 3680121) Inactivates airborne molds, allergens and even viruses. Welcome the Plasmacluster Ion Generator for a healthier and more comfortable workplace. Sharp’s Plasmacluster is the only technology that uses positive and negative ions to disinfect the air. High density and long-lasting ions make a powerful attack on dirty air across the entire room. How Plasmacluster ions are generated Positive and negative voltages are applied to discharge electrodes in order to electrically breakdown water and oxygen molecules in the air. This produces positive hydrogen ions and negative oxygen ions. Plasmacluster ions are the same positive and negative ions found in nature. The ions are long lasting as surrounded by water molecules, and are released into the air. Positive hydrogen ion H+ Mold Spores Negative oxygen ion O 2- H+ O 2- Airborne water Airborne oxygen H 2O Hydroxide (OH) radical H 2O O2 O2 Viruses Hydrogen (H) Discharge electrode (+) Plasma area Discharge electrode (-) Plasma area Protein The airborne water molecules cluster around the ions like a bunch of grapes, transforming each ion into a stable cluster ion. Dust Mite Feces The ions form hydroxide radicals that are highly oxidizing only when they adhere to the surfaces of mold and viruses. They instantly remove the hydrogen from the surface proteins, breaking them down. The formed ions are unstable on their own. Positive ion Negative ion H+ H 2O H 2O H 2O H+ H 2O O 2- H 2O H 2O H 2O O 2- H2O H 2O H 2O “High density Plasmacluster ion generating unit” Water molecules cluster around the ion to stabilize it. The hydroxide (OH) radicals combine with hydrogen (H) to form water (H2O) which returns to the air. When Plasmacluster ions stick to the surface of the airborne substances, they instantly form OH radicals of strong standard oxidation potential that robs hydrogen from the protein of the airborne substances. Inactivation of mold Sharp continues research into air purification because of growing social awareness, with the primar y wish of bringing cleaner air to the world. Sharp’s original Plasmacluster technology inactivates harmful airborne substances, and that performance has been steadily improved since its development in 2000. From the home to the office. From Japan to the world. We pursue even higher performance as the means for bringing cleaner air to more places. We want to spread this new culture of air purification around the world. Inactivation of Inactivation of viruses allergens Inactivation of adhering odour Plasmacluster ions generate OH radicals. Oxidized substance (Substance robbed of H+) Chemical formula Standard oxidation potential (Power to steal H+) Oxygen radical • OH 2.81 Oxygen atom O 2.42 Ozone O3 2.07 Hydrogen peroxide H2 O 2 1.78 Oxygen molecule O2 1.23 Source: Ozone Fundamentals and Applications • To enable stable emission of high-density Plasmacluster ions, the Plasmacluster ion generating unit module will need to be replaced periodically*. * Replacement is required approximately every 17,500 hours, roughly 2 years when operated continuously for 24 hours a day. Unit will stop operating after about 19,000 hours (2 years and 2 months) if the Plasmacluster ion generating unit is not replaced. 1 • The final product appearance may differ from the product photos and unit photos in this catalogue. 2 Airborne molds and allergens are problems the more crowded a place is. Plasmacluster technology There are many hazardous substances around us that are invisible to the eye. Air quality has become an issue in places where people Plasma discharge generates and emits the same positive and negative ions that occur in nature. Plasmacluster technology is Sharp’s original air disinfecting technology that inactivates suspended airborne mold and viruses. gather such as offices, stores, hotels, schools, hospitals and so forth. The airborne molds, viruses and allergens that permeate these places are a major cause of discomfort to guests and people who work there. Because of these times, Sharp developed proprietary Plasmacluster technology that powerfully inactivates harmful airborne substances that permeate indoor air environments. Winner of the Invention Prize at the 2008 National Invention Awards Ceremony held by the Japan Institute of Invention and Innovation (JIII) What Sharp hopes for is to contribute in whatever way it can to making business environments healthier and more comfortable. Patented by Sharp (patent No. 3680121) Inactivates airborne molds, allergens and even viruses. Welcome the Plasmacluster Ion Generator for a healthier and more comfortable workplace. Sharp’s Plasmacluster is the only technology that uses positive and negative ions to disinfect the air. High density and long-lasting ions make a powerful attack on dirty air across the entire room. How Plasmacluster ions are generated Positive and negative voltages are applied to discharge electrodes in order to electrically breakdown water and oxygen molecules in the air. This produces positive hydrogen ions and negative oxygen ions. Plasmacluster ions are the same positive and negative ions found in nature. The ions are long lasting as surrounded by water molecules, and are released into the air. Positive hydrogen ion H+ Mold Spores Negative oxygen ion O 2- H+ O 2- Airborne water Airborne oxygen H 2O Hydroxide (OH) radical H 2O O2 O2 Viruses Hydrogen (H) Discharge electrode (+) Plasma area Discharge electrode (-) Plasma area Protein The airborne water molecules cluster around the ions like a bunch of grapes, transforming each ion into a stable cluster ion. Dust Mite Feces The ions form hydroxide radicals that are highly oxidizing only when they adhere to the surfaces of mold and viruses. They instantly remove the hydrogen from the surface proteins, breaking them down. The formed ions are unstable on their own. Positive ion Negative ion H+ H 2O H 2O H 2O H+ H 2O O 2- H 2O H 2O H 2O O 2- H2O H 2O H 2O “High density Plasmacluster ion generating unit” Water molecules cluster around the ion to stabilize it. The hydroxide (OH) radicals combine with hydrogen (H) to form water (H2O) which returns to the air. When Plasmacluster ions stick to the surface of the airborne substances, they instantly form OH radicals of strong standard oxidation potential that robs hydrogen from the protein of the airborne substances. Inactivation of mold Sharp continues research into air purification because of growing social awareness, with the primar y wish of bringing cleaner air to the world. Sharp’s original Plasmacluster technology inactivates harmful airborne substances, and that performance has been steadily improved since its development in 2000. From the home to the office. From Japan to the world. We pursue even higher performance as the means for bringing cleaner air to more places. We want to spread this new culture of air purification around the world. Inactivation of Inactivation of viruses allergens Inactivation of adhering odour Plasmacluster ions generate OH radicals. Oxidized substance (Substance robbed of H+) Chemical formula Standard oxidation potential (Power to steal H+) Oxygen radical • OH 2.81 Oxygen atom O 2.42 Ozone O3 2.07 Hydrogen peroxide H2 O 2 1.78 Oxygen molecule O2 1.23 Source: Ozone Fundamentals and Applications • To enable stable emission of high-density Plasmacluster ions, the Plasmacluster ion generating unit module will need to be replaced periodically*. * Replacement is required approximately every 17,500 hours, roughly 2 years when operated continuously for 24 hours a day. Unit will stop operating after about 19,000 hours (2 years and 2 months) if the Plasmacluster ion generating unit is not replaced. 1 • The final product appearance may differ from the product photos and unit photos in this catalogue. 2 Progressing further, high-density Plasmacluster technology. Higher ion density for an increased effect. “Plasmacluster” is an original technology of Sharp for purifying air by discharging highly stable + and – ions similar to those that exist in the natural world. It inactivates a number of airborne substances such as molds, viruses and allergens. Its effect has been verified by public testing institutions around the world. Proven Effectiveness of Plasmacluster Ions Effectiveness rises with increasing density. Inactivation of viruses Increasing viruses inactivation performance by increasing ion density Reduction of airborne viruses High-density Plasmacluster ions are highly effective at inactivating suspended viruses. They inactivate 99.9% of suspended viruses. (Experimental result for 1 m3 box) Without Plasmacluster ions Reduction of airborne viruses Percent remaining : 100% (Experimental result for 1 m3 box) With Plasmacluster ions 99% inhibited in about 10 minutes. (7,000 ions/cm3) 10% 50% Natural attenuation 60 With Plasmacluster ions (3,000 ions/cm3) 40 20 0 30 60 90 120 150 180 195 (Min.) • Tested by: Ishikawa Health Service Association • Test method: Plasmacluster ions were emitted into an experimental chamber with a floor area of about 13 m2, and the suspended mold was measured with an air sampler. Sharp has graphed the results using approximate figures. (Plasmacluster ion density: 3,000 ions/cm3) Inactivation of adhering odour 0.1% 1% Identification of ion types 100% The types of Plasmacluster ions have been identified and verified to be the same as naturally existing ions. • Tested by: Japan Food Research Laboratories • Test results: No. 208070713-001 of July 23, 2008 • Test method: Sharp generated ions in a space of 2.6 m3, grew mold on PVC plates for 5 days, and entrusted them to test institution. Mold growth areas were compared as directed by JIS Z2911. Sharp plotted the results. (Plasmacluster ion density: 50,000 ions/cm3) Mold exposed to Plasmacluster ions 3 (50,000 ions/cm ) * The ion density generated when operated at the HIGH airstream setting, measured a horizontal distance of 2 meters (in the direction of ion emission), at a height of 1.2 meters from the floor. 50 to 100% of total 4 The same type of ions as those in nature 3 Plasmacluster ions are positive and negative ions that adhere to the surfaces of suspended airborne microbes and form highly oxidizing hydroxide radicals that physically break down and remove the proteins on the surfaces of suspended microbes. Since they are the same as naturally occurring ions while airborne, they can exist in higher densities in homes. 0 to 25% of total 2 1 0 Mold exposed to Plasmacluster ions Mold allowed to grow naturally (50,000 ions/cm3)* Mold allowed to grow naturally GLP*-compliant test facilities have gathered highly reliable safety data on Sharp’s Plasmacluster technology. • Skin irritation/corrosion test • Eye irritation/corrosion test • Inhalation toxicity test (lung tissue genetic impact assessment) Tested by: Mitsubishi Chemical Safety Institute * GLP (Good Laboratory Practice) is a system of management controls for test facilities and test procedures designed to ensure the reliability of chemical safety assessment tests. Increase in adhering odour removal speed: Approx. doubled* High-density Plasmacluster ions increase deodorizing speed. They reduced cigarette smoke odour in a room to an unnoticeable level in about 60 minutes. Removing cigarette smoke odour Reducing cigarette smoke odour from cloth Deodorizes to unnoticeable level in about 2 hours. 2.0 2 5 • Tested by: Japan Spinners Inspecting Foundation • Test method: The deodorizing effectiveness on a cloth swatch impregnated with cigarette smoke odour components was evaluated by the six-level odour intensity indication method. Sharp has converted and calculated the results. 4 Odour intensity 3.1 1 Ratio of suspended viruses remaining: Inactivated by 99.9% in about 10 minutes. Reduction of growth of adhering mold Elimination Percent remaining (%) 80 0 The ions react only with the protein on the surface of airborne substances without affecting internal cells, etc. High-density Plasmacluster ions inactivate suspended mold and reduce the growth of adhered mold. 100 (5,000 ions/cm3) 1% Reducing growth of adhering mold Reduction of airborne mold With Plasmacluster ions Highly reliable safety data has already been obtained by GLP* (Good Laboratory Practice) compliant test institutes. With Plasmacluster ions (50,000 ions/cm3)* 0.1% Natural decrease Identification of active mechanism Ratio of suspended viruses remaining: 99% inactivated in about 10 minutes. * The ion density generated when operated at the HIGH airstream setting, measured a horizontal distance of 2 meters (in the direction of ion emission), at a height of 1.2 meters from the floor. Inactivation of mold Obtaining of safety data With Plasmacluster ions (7,000 ions/cm3) 100% • Tested by: Retroscreen Virology Ltd., UK • Test method: Viruses were suspended in the air in a 1 m3 box, and the percentage of airborne viruses inactivated was measured. (Plasmacluster ion density: 7,000 ions/cm3) Safety verification of Plasmacluster Percent remaining: 100% • Tested by: Retroscreen Virology Ltd., UK • Test method: Viruses were suspended in the air in a 1 m3 box, and the percentage of airborne viruses inactivated was measured. Area of mold filaments grown Without Plasmacluster ions Plasmacluster ions are the same as ions found in nature, and their safety has been verified. 3 Odour intensity Inactivation effectiveness for dust mite allergens in suspended house dust Plasmacluster ions cut through and remove proteins in suspended allergens generated by dust mite feces and dead mites, reducing their effects. Dust mite feces Dead dust mite Natural decrease Sales of Products Equipped with Sharp’s Plasmacluster Ion Technology Has Reached 20 Million* Units Worldwide. 2 0 Plasmacluster ions (ion density: 20,000 ions/cm3) Deodorizing speed: Approx. doubled* 60 minutes 2 hours later 2 Density change in airborne dust mite allergens (pg/cm3) Inactivation of allergens from dead dust mites and dust mite feces * Comparison of 5,000 ions/cm3 and 20,000 ions/cm3 Plasmacluster ion densities Reduces odour to unnoticeable level in about 60 minutes. 3 1 • Tested by: Japan Spinners Inspecting Foundation • Test method: The deodorizing effectiveness on a cloth swatch impregnated with cigarette smoke odour components was evaluated by the six-level odour intensity indication method. Sharp has converted and calculated the results. (Plasmacluster ion density: 5,000 ions/cm3) Plasmacluster ions (ion density 5,000 ions/cm3) Increase Without Plasmacluster ions Stops allergens increasing. With Plasmacluster ions (3,000 ions/cm3) Initial value 1 • Tested by: Hiroshima University Graduate School of Advanced Sciences of Matter • Test method: The effect of dust mite allergens in an uncleaned room (with a floor area of about 13 m2) was measured in an actual home by the ELISA (Enzyme-Linked ImmunoSorbant Assay) method. Sharp converted the results and calculated the average value. (Plasmacluster ion density: 3,000 ions/cm3) * Total number of Sharp Plasmacluster products and Plasmacluster ion generating devices shipped within Japan and overseas between October 2000 and December 2008. • While it can inactivate suspended viruses and other contaminants, it cannot create a completely sterile environment. Sharp does not guarantee its ability to prevent microbial infection. • Actual numbers of ions and disinfecting/purifying effectiveness will vary according to the room conditions and operating method. 3 4 Progressing further, high-density Plasmacluster technology. Higher ion density for an increased effect. “Plasmacluster” is an original technology of Sharp for purifying air by discharging highly stable + and – ions similar to those that exist in the natural world. It inactivates a number of airborne substances such as molds, viruses and allergens. Its effect has been verified by public testing institutions around the world. Proven Effectiveness of Plasmacluster Ions Effectiveness rises with increasing density. Inactivation of viruses Increasing viruses inactivation performance by increasing ion density Reduction of airborne viruses High-density Plasmacluster ions are highly effective at inactivating suspended viruses. They inactivate 99.9% of suspended viruses. (Experimental result for 1 m3 box) Without Plasmacluster ions Reduction of airborne viruses Percent remaining : 100% (Experimental result for 1 m3 box) With Plasmacluster ions 99% inhibited in about 10 minutes. (7,000 ions/cm3) 10% 50% Natural attenuation 60 With Plasmacluster ions (3,000 ions/cm3) 40 20 0 30 60 90 120 150 180 195 (Min.) • Tested by: Ishikawa Health Service Association • Test method: Plasmacluster ions were emitted into an experimental chamber with a floor area of about 13 m2, and the suspended mold was measured with an air sampler. Sharp has graphed the results using approximate figures. (Plasmacluster ion density: 3,000 ions/cm3) Inactivation of adhering odour 0.1% 1% Identification of ion types 100% The types of Plasmacluster ions have been identified and verified to be the same as naturally existing ions. • Tested by: Japan Food Research Laboratories • Test results: No. 208070713-001 of July 23, 2008 • Test method: Sharp generated ions in a space of 2.6 m3, grew mold on PVC plates for 5 days, and entrusted them to test institution. Mold growth areas were compared as directed by JIS Z2911. Sharp plotted the results. (Plasmacluster ion density: 50,000 ions/cm3) Mold exposed to Plasmacluster ions 3 (50,000 ions/cm ) * The ion density generated when operated at the HIGH airstream setting, measured a horizontal distance of 2 meters (in the direction of ion emission), at a height of 1.2 meters from the floor. 50 to 100% of total 4 The same type of ions as those in nature 3 Plasmacluster ions are positive and negative ions that adhere to the surfaces of suspended airborne microbes and form highly oxidizing hydroxide radicals that physically break down and remove the proteins on the surfaces of suspended microbes. Since they are the same as naturally occurring ions while airborne, they can exist in higher densities in homes. 0 to 25% of total 2 1 0 Mold exposed to Plasmacluster ions Mold allowed to grow naturally (50,000 ions/cm3)* Mold allowed to grow naturally GLP*-compliant test facilities have gathered highly reliable safety data on Sharp’s Plasmacluster technology. • Skin irritation/corrosion test • Eye irritation/corrosion test • Inhalation toxicity test (lung tissue genetic impact assessment) Tested by: Mitsubishi Chemical Safety Institute * GLP (Good Laboratory Practice) is a system of management controls for test facilities and test procedures designed to ensure the reliability of chemical safety assessment tests. Increase in adhering odour removal speed: Approx. doubled* High-density Plasmacluster ions increase deodorizing speed. They reduced cigarette smoke odour in a room to an unnoticeable level in about 60 minutes. Removing cigarette smoke odour Reducing cigarette smoke odour from cloth Deodorizes to unnoticeable level in about 2 hours. 2.0 2 5 • Tested by: Japan Spinners Inspecting Foundation • Test method: The deodorizing effectiveness on a cloth swatch impregnated with cigarette smoke odour components was evaluated by the six-level odour intensity indication method. Sharp has converted and calculated the results. 4 Odour intensity 3.1 1 Ratio of suspended viruses remaining: Inactivated by 99.9% in about 10 minutes. Reduction of growth of adhering mold Elimination Percent remaining (%) 80 0 The ions react only with the protein on the surface of airborne substances without affecting internal cells, etc. High-density Plasmacluster ions inactivate suspended mold and reduce the growth of adhered mold. 100 (5,000 ions/cm3) 1% Reducing growth of adhering mold Reduction of airborne mold With Plasmacluster ions Highly reliable safety data has already been obtained by GLP* (Good Laboratory Practice) compliant test institutes. With Plasmacluster ions (50,000 ions/cm3)* 0.1% Natural decrease Identification of active mechanism Ratio of suspended viruses remaining: 99% inactivated in about 10 minutes. * The ion density generated when operated at the HIGH airstream setting, measured a horizontal distance of 2 meters (in the direction of ion emission), at a height of 1.2 meters from the floor. Inactivation of mold Obtaining of safety data With Plasmacluster ions (7,000 ions/cm3) 100% • Tested by: Retroscreen Virology Ltd., UK • Test method: Viruses were suspended in the air in a 1 m3 box, and the percentage of airborne viruses inactivated was measured. (Plasmacluster ion density: 7,000 ions/cm3) Safety verification of Plasmacluster Percent remaining: 100% • Tested by: Retroscreen Virology Ltd., UK • Test method: Viruses were suspended in the air in a 1 m3 box, and the percentage of airborne viruses inactivated was measured. Area of mold filaments grown Without Plasmacluster ions Plasmacluster ions are the same as ions found in nature, and their safety has been verified. 3 Odour intensity Inactivation effectiveness for dust mite allergens in suspended house dust Plasmacluster ions cut through and remove proteins in suspended allergens generated by dust mite feces and dead mites, reducing their effects. Dust mite feces Dead dust mite Natural decrease Sales of Products Equipped with Sharp’s Plasmacluster Ion Technology Has Reached 20 Million* Units Worldwide. 2 0 Plasmacluster ions (ion density: 20,000 ions/cm3) Deodorizing speed: Approx. doubled* 60 minutes 2 hours later 2 Density change in airborne dust mite allergens (pg/cm3) Inactivation of allergens from dead dust mites and dust mite feces * Comparison of 5,000 ions/cm3 and 20,000 ions/cm3 Plasmacluster ion densities Reduces odour to unnoticeable level in about 60 minutes. 3 1 • Tested by: Japan Spinners Inspecting Foundation • Test method: The deodorizing effectiveness on a cloth swatch impregnated with cigarette smoke odour components was evaluated by the six-level odour intensity indication method. Sharp has converted and calculated the results. (Plasmacluster ion density: 5,000 ions/cm3) Plasmacluster ions (ion density 5,000 ions/cm3) Increase Without Plasmacluster ions Stops allergens increasing. With Plasmacluster ions (3,000 ions/cm3) Initial value 1 • Tested by: Hiroshima University Graduate School of Advanced Sciences of Matter • Test method: The effect of dust mite allergens in an uncleaned room (with a floor area of about 13 m2) was measured in an actual home by the ELISA (Enzyme-Linked ImmunoSorbant Assay) method. Sharp converted the results and calculated the average value. (Plasmacluster ion density: 3,000 ions/cm3) * Total number of Sharp Plasmacluster products and Plasmacluster ion generating devices shipped within Japan and overseas between October 2000 and December 2008. • While it can inactivate suspended viruses and other contaminants, it cannot create a completely sterile environment. Sharp does not guarantee its ability to prevent microbial infection. • Actual numbers of ions and disinfecting/purifying effectiveness will vary according to the room conditions and operating method. 3 4 Discharges a high density Plasmacluster ions across a wide area to quickly and powerfully inactivate airborne substances and purify air in crowded places. The delivery mechanism is Sharp's original technology for applying flow control. Technology for delivering high density Plasmacluster around people A high density of Plasmacluster ions inactivate airborne substances and purify air across a wide area where people are active. Ions follow the layer of air across the room. The layer of air presses on the ions. The airflow blown from the highest louver creates a layer of air that presses on the ions to ensure a high density reaches far across the room. It simultaneously generates a large quantity of Plasmacluster ions and delivers them far across the entire room. Delivered in high density, the Plasmacluster ions powerfully inactivate airborne molds and viruses. Efficiently releases a high density ions across wide areas. Wide louver for high output. The wide louver the product employs efficiently releases a high density of Plasmacluster ions across wide areas such as lobbies and waiting rooms. The airflow near the Plasmacluster ion generating unit increases to produce more ions. Delivery range of high density Plasmacluster ions Applicable floor surface area: Approx. 50 m2 Approx. 6 m Applicable floor surface area: Approx. 50 m2 Airflow is evenly divided by the Coanda effect of the internal walls of the air channel. 480 mm *What is the Coanda effect? It is a characteristic of air and liquid jets that, when blown along surfaces, tend to follow the surface even if exhausted or curved downstream. Approx. 8 m Applicable floor surface area: Approx. 23 m2 Approx. 3 m Approx. 7.5 m •Actual numbers of ions and disinfecting/purifying effectiveness will vary according to the room conditions and operating method. Applicable floor surface area: Approx. 23 m2 940 mm Higher ion densities with a Plasmacluster ion generating unit. The Plasmacluster ion generating device has been built and incorporated as a detachable modular unit, which both increases the density of the ion flow and ensures a stable consistent flow of ions at all times. A lamp on the front panel of the product notifies the user when it is time to replace the unit. 480 mm Wall surface Profile 60 mm or more 230 mm Plasmacluster ion generating unit for replacement (Plasmacluster ion generating unit will need to be replaced periodically.) *After about 17,500 total hours of operations (about 2 years when run continuously 24 hours a day), a lamp on the front panel starts flashing to notify the user that it is time to replace the unit. Filter cleaning lamp Unit replacement lamp Air volume lamp 594 mm Plasmacluster ion generating unit replacement •The Plasmacluster ion generating unit will need to be replaced periodically to enable continuous stable emission of high-density Plasmacluster ions. •The product stops running after about 19,000 hours (approx. 2 years and 2 months) if the unit is not replaced. •The Plasmacluster ion generating unit may need to be replaced sooner when used in some environments or locations (such as locations of suspended cooking oil droplets or other oil components, dusty or humid locations, or locations where sprays or chemicals are used). Designed for both low power consumption and quiet operation for comfortable use year-round The product is designed to consume about 10 W*. Furthermore, the operating noise is the same 34 db* demanded for libraries, so the product can be used comfortably all year-round. 5 • The final product appearance may differ from the product photos and unit photos in this catalogue. Breaker interlock to prevent unnecessary running If the breaker interlock switch is set in the ON position and then the product is accidentally unplugged or the breaker trips during use, the last used operating mode resumes automatically when power is restored. 6 Discharges a high density Plasmacluster ions across a wide area to quickly and powerfully inactivate airborne substances and purify air in crowded places. The delivery mechanism is Sharp's original technology for applying flow control. Technology for delivering high density Plasmacluster around people A high density of Plasmacluster ions inactivate airborne substances and purify air across a wide area where people are active. Ions follow the layer of air across the room. The layer of air presses on the ions. The airflow blown from the highest louver creates a layer of air that presses on the ions to ensure a high density reaches far across the room. It simultaneously generates a large quantity of Plasmacluster ions and delivers them far across the entire room. Delivered in high density, the Plasmacluster ions powerfully inactivate airborne molds and viruses. Efficiently releases a high density ions across wide areas. Wide louver for high output. The wide louver the product employs efficiently releases a high density of Plasmacluster ions across wide areas such as lobbies and waiting rooms. The airflow near the Plasmacluster ion generating unit increases to produce more ions. Delivery range of high density Plasmacluster ions Applicable floor surface area: Approx. 50 m2 Approx. 6 m Applicable floor surface area: Approx. 50 m2 Airflow is evenly divided by the Coanda effect of the internal walls of the air channel. 480 mm *What is the Coanda effect? It is a characteristic of air and liquid jets that, when blown along surfaces, tend to follow the surface even if exhausted or curved downstream. Approx. 8 m Applicable floor surface area: Approx. 23 m2 Approx. 3 m Approx. 7.5 m •Actual numbers of ions and disinfecting/purifying effectiveness will vary according to the room conditions and operating method. Applicable floor surface area: Approx. 23 m2 940 mm Higher ion densities with a Plasmacluster ion generating unit. The Plasmacluster ion generating device has been built and incorporated as a detachable modular unit, which both increases the density of the ion flow and ensures a stable consistent flow of ions at all times. A lamp on the front panel of the product notifies the user when it is time to replace the unit. 480 mm Wall surface Profile 60 mm or more 230 mm Plasmacluster ion generating unit for replacement (Plasmacluster ion generating unit will need to be replaced periodically.) *After about 17,500 total hours of operations (about 2 years when run continuously 24 hours a day), a lamp on the front panel starts flashing to notify the user that it is time to replace the unit. Filter cleaning lamp Unit replacement lamp Air volume lamp 594 mm Plasmacluster ion generating unit replacement •The Plasmacluster ion generating unit will need to be replaced periodically to enable continuous stable emission of high-density Plasmacluster ions. •The product stops running after about 19,000 hours (approx. 2 years and 2 months) if the unit is not replaced. •The Plasmacluster ion generating unit may need to be replaced sooner when used in some environments or locations (such as locations of suspended cooking oil droplets or other oil components, dusty or humid locations, or locations where sprays or chemicals are used). Designed for both low power consumption and quiet operation for comfortable use year-round The product is designed to consume about 10 W*. Furthermore, the operating noise is the same 34 db* demanded for libraries, so the product can be used comfortably all year-round. 5 • The final product appearance may differ from the product photos and unit photos in this catalogue. Breaker interlock to prevent unnecessary running If the breaker interlock switch is set in the ON position and then the product is accidentally unplugged or the breaker trips during use, the last used operating mode resumes automatically when power is restored. 6 Plasmacluster Ion Generator Sales of Products Equipped with Sharp’s Plasmacluster Ion Technology Has Reached * Worldwide Powerfully Inactivate Airborne Substances High Density Plasmacluster Technology Incorporated Design and specifications subject to change without notice. Sharp is a registered trademark of Sharp Corporation. All other trademarks and registered trademarks are property of their respective holders. SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road East, Mississauga, Ontario L4Z 1W9 (905) 890-2100 • www.sharp.ca ©2009 Sharp Electronics of Canada Ltd. Printed in Canada. M6442
Similar documents
Plasmacluster
chamber (diameter: 5.5 cm, length: 20 cm) through which airborne influenza (approx. 2,000 pts per 300 L of air) are passed at the speed of approx. 4 m/sec and the inactivation rate is measured. Thi...
More information