Tracheostomy Tubes and Accessories Catalogue
Transcription
Tracheostomy Tubes and Accessories Catalogue
Tracheostomy Tubes and Accessories Catalogue 1 2 Tracheostomy Catalogue Contents Shiley™ tracheostomy tubes . . . . . . . . . . . . . 4 Shiley™ DCT & DFEN & PERC™ cuffed . . . . . . . . 5 Shiley™ DCFS & DCFN cuffed . . . . . . . . . . . . . 6 Shiley™ LPC & FEN cuffed . . . . . . . . . . . . . . 7 Shiley™ CFS, CFN and LGT cuffed . . . . . . . . . . 8 Shiley™ PED, PDC, PLC and NEO . . . . . . . . . . . 9 Tracheosoft™ . . . . . . . . . . . . . . . . . . . . 10 Tracheosoft™ Standard . . . . . . . . . . . . . . . . 11 SealGuard™ . . . . . . . . . . . . . . . . . . . . . 12 EVAC concept . . . . . . . . . . . . . . . . . . . . 13 Lanz™ System . . . . . . . . . . . . . . . . . . . . 14 Tracheosoft™ Reinforced . . . . . . . . . . . . . . . 15 Tracheosoft™ EVAC & Pitt™ . . . . . . . . . . . . . 16 Tracheosoft™ PERC™ . . . . . . . . . . . . . . . . . 17 Tracheosoft™ XLT . . . . . . . . . . . . . . . . . . 18 Argyle™ Silicone . . . . . . . . . . . . . . . . . . . 20 TLT kit . . . . . . . . . . . . . . . . . . . . . . . . 21 Accessories . . . . . . . . . . . . . . . . . . . . . 22 3 Shiley™ tracheostomy tubes World leader for more than 30 years Shiley™ brand tracheostomy tubes have been manufactured for all clinical indications for more than 30 years. Thanks to patient orientated design, Shiley™ tracheostomy tubes have earned an excellent reputation all over the world. Every Shiley™ tube meets strict international standards and is subjected to intense quality controls. The result is a reliable, quality product for use in both hospitals and home care applications. The special manufacturing process which makes both the outer and inner cannula simultaneously, means that Shiley™ reusable inner cannula tubes are an exceptional fit to the outer cannula. This results in major benefits for both patients and staff. This helps prevent secretions from tracking between the inner and outer cannula, and prevents tissue overgrowth into the distal tip of the tube. Innovation in cuff technology will enable us over the next couple of years to commence an ongoing programme of adding the SealGuard™ cuff technology to some products. SealGuard™ cuff technology is an ultra-thin strong polyurethane material that allows sealing at lower cuff pressures and through the reduced channelling effect, has potential to reduce Ventilator Associated Pneumonia. Unusual anatomy sometimes means that standard tubes are not suitable. We are able to supply custom made products meeting individual specific requirements. 4 Tracheostomy Catalogue Shiley™ DCT & DFEN & PERC™ Cuffed tracheostomy tubes with disposable inner cannula Pack includes: DCTDisposable Low Pressure Cuffed Tracheostomy Tube provides the convenience of a disposable inner cannula for a wide variety of applications. DFENDisposable Fenestrated Low Pressure Cuffed Tracheostomy Tube offers inner cannula disposability, permitting to breathe through upper airway if desired. PERC™ Disposable Low Pressure Cuffed Percutaneous Tracheostomy Tube (PERC™) is specially designed to work with Cook™* PERC™ Percutaneous Tracheostomy Introducer Sets (same set configuration as DCT).1 a.Disposable Inner Cannula (DIC) has integral 15 mm snap-lock connector for quick and safe disposal after a single use. b.Smooth, rounded-tip obturator facilitates insertion. c.Disposable Decannulation Plug (DDCP) closes the proximal end of the DCFS, DCFN and DFEN permitting the patient to breathe through the fenestration and the upper airway. 1 Introducer sold separately by Cook Critical Care, Bloomington, IN ™* Cook is a trademark of Cook Critical Care, Bloomington, IN. Ordering information: REF Size I.D. (mm) O.D. (mm) Length (mm) Cuff Ø (mm) DCT 4DCT 4 5,0 9,4 62 20 6DCT 6 6,4 10,8 74 24 8DCT 8 7,6 12,2 79 27 10DCT 10 8,9 13,8 79 29 DFEN 4DFEN 4 5,0 9,4 62 20 6DFEN 6 6,4 10,8 74 24 8DFEN 8 7,6 12,2 79 27 10DFEN 10 8,9 13,8 79 29 PERC™ 6PERC 6 6,4 10,8 74 8PERC 8 7,6 12,2 79 Carton Quantity: 1 REF Size Required for use with DIC 4DIC 4 4DCT 4DFEN 6DIC 6 6DCT 6DFEN 6PERC 8DIC 8 8DCT 8DFEN 8PERC 10DIC 10 10DCT 10DFEN Carton Quantity: 10 Shiley™ tracheostomy tubes and Disposable Inner cannula (DIC) are single packed and sterile. 5 Shiley™ DCFS & DCFN Cuffless tracheostomy tubes with disposable inner cannula Pack includes: DCFSDisposable Cuffless Tracheostomy Tube provides the convenience of a Disposable Inner Cannula for a wide variety of applications. DCFNDisposable Cuffless Fenesrated Tracheostomy Tube allows the convenience of inner cannula disposability, while permitting the patient to breathe through the upper airway if desired. a.Disposable Inner Cannula (DIC) with integral 15 mm snap-lock connector for quick and safe disposal after a single use. b.Smooth, rounded-tip obturator facilitates insertion. c.Disposable Decannulation Plug (DDCP) closes the proximal end of the DCFS, DCFN and DFEN to permit breathing through the fenestration and the upper airway. 6 Ordering information: REF Size I.D. (mm) O.D. (mm) Length (mm) DCFS 4DCFS 4 5,0 9,4 62 6DCFS 6 6,4 10,8 74 8DCFS 8 7,6 12,2 79 10DCFS 10 8,9 13,8 79 DCFN 4DCFN 4 5,0 9,4 62 6DCFN 6 6,4 10,8 74 8DCFN 8 7,6 12,2 79 10DCFN 10 8,9 13,8 79 Carton Quantity: 1 REF Size Required for use with DIC 4DIC 4 4DCFS 4DCFN 6DIC 6 6DCFS 6DCFN 8DIC 8 8DCFS 8DCFN 10DIC 10 10DCFS 10DCFN Carton Quantity: 10 Shiley™ tracheostomy tubes are single packed and sterile. Tracheostomy Catalogue Shiley™ LPC & FEN Cuffed tracheostomy tube with reusable inner cannula Pack includes: LPCLow Pressure Cuffed Tracheostomy Tube protects delicate tissue with its cylindrical cuff and is manufactured of high-quality, compliant material that softens at body temperature. FENFenestrated Low Pressure Cuffed Tracheostomy Tube allows for weaning of patient from tube by facilitating upper airway breathing. a.Inner Cannula with integral 15 mm twist-lock connector permits connection of ancillary equipment and is translucent for easy inspection. b.Fenestrated Inner Cannula with green 15 mm connector and white 15 mm-cap. c.Smooth, rounded-tip obturator facilitates insertion. d.Decannulation Plug (DCP) is connected to the outer cannula to permit upper airway breathing. Ordering information: REF Size I.D. (mm) O.D. (mm) Length (mm) LPC 4LPC 4 5,0 9,4 65 6LPC 6 6,4 10,8 76 8LPC 8 7,6 12,2 81 10LPC 10 8,9 13,8 81 FEN 4FEN 4 5,0 9,4 65 6FEN 6 6,4 10,8 76 8FEN 8 7,6 12,2 81 10FEN 10 8,9 13,8 81 Carton Quantity: 1 Shiley™ tracheostomy tubes are single packed and sterile. Cuff Ø (mm) 20 24 27 29 20 24 27 29 7 Shiley™ CFS, CFN and LGT Cuffless tracheostomy tubes with reusable inner cannula Pack includes: CFSCuffless Tracheostomy Tube is designed for general pulmonary hygiene and for use with spontaneously breathing patients. CFNCuffless Fenestrated Tube is designed for pulmonary hygiene and, when used in conjunction with the Decannulation Plug (DCP), use of a speaking valve, directs breathing through the upper airway. LGTLaryngectomy Tube is made with high-quality, compliant material, and is a comfortable, convenient alternative to metal tubes. a.Inner Cannula with integral 15 mm twist-lock connector permits connection of ancillary equipment and is translucent for easy inspection. b.Inner Cannula with open lumen and low-profile connector reduces bulk at stoma. (Caution: low profile inner cannula is not adaptable to ventilator equipment.) c.Inner Cannula with closed lumen and low-profile connector is supplied with the CFS and directs breathing through the upper airway. d.Fenestrated Inner Cannula with green 15 mm connector and white 15 mm-cap e.Smooth, rounded-tip obturator facilitates insertion. f.Decannulation Plug (DCP) closes the proximal end of the CFN to permit breathing through the fenestration and upper airway. 8 Ordering information: REF Size I.D. (mm) O.D. (mm) CFS 4CFS 4 5,0 9,4 6CFS 6 6,4 10,8 8CFS 8 7,6 12,2 10CFS 10 8,9 13,8 CFN 4CFN 4 5,0 9,4 6CFN 6 6,4 10,8 8CFN 8 7,6 12,2 10CFN 10 8,9 13,8 LGT 6LGT 6 6,4 11,1 8LGT 8 7,6 12,6 10LGT 10 8,9 13,7 Carton Quantity: 1 Shiley™ tracheostomy tubes are single packed and sterile. Length (mm) 65 76 81 81 65 76 81 81 50 50 50 Tracheostomy Catalogue Shiley™ PED, PDC, PLC and NEO Cuffed and cuffless paediatric and neonatal tracheostomy tubes Pack includes: •All Shiley™ Neonatal and Paediatric Tracheostomy Tubes have a recessed area behind the connector to provide greater comfort. •The Neonatal Tracheostomy Tube (NEO) features a lower flange angle to improve fit. •The Long Paediatric Tracheostomy Tube (PDL) offers a longer cannula to fit larger paediatric patients. •The economical Cuffed Paediatric Tracheostomy Tube (PDC) and the Cuffed Long Paediatric Tracheostomy Tube (PLC) feature gentle cylindrical cuffs. Ordering information: REF Size I.D. (mm) Ordering information: O.D. (mm) NEO 3.0NEO 3,0 3,0 4,5 3.5NEO 3,5 3,5 5,2 4.0NEO 4,0 4,0 5,9 4.5NEO 4,5 4,5 6,5 PED 3.0PED 3,0 3,0 4,5 3.5PED 3,5 3,5 5,2 4.0PED 4,0 4,0 5,9 4.5PED 4,5 4,5 6,5 5.0PED 5,0 5,0 7,1 5.5PED 5,5 5,5 7,7 PDL 5.0PDL 5,0 5,0 7,1 5.5PDL 5,5 5,5 7,7 6.0PDL 6,0 6,0 8,3 6.5PDL 6,5 6,5 9,0 Carton Quantity: 1 Shiley™ tracheostomy tubes are single packed and sterile. Length (mm) 30 32 34 36 39 40 41 42 44 45 REF Size PDC 4.0PDC 4,0 4.5PDC 4,5 5.0PDC 5,0 5.5PDC 5,5 PLC 5.0PLC 5,0 5.5PLC 5,5 6.0PLC 6,0 6.5PLC 6,5 Carton Quantity: 1 I.D. (mm) O.D. (mm) Length (mm) Cuff Ø (mm) 4,0 4,5 5,0 5,5 5,9 6,5 7,1 7,7 41 42 44 46 12.4 12.5 15.0 14.9 5,0 5,5 6,0 6,5 7,1 7,7 8,3 9,0 50 52 54 56 15.0 14.9 19.3 19.3 50 52 54 56 9 Tracheosoft™ Advanced technology for better safety Tracheosoft™ tracheostomy tubes are designed to minimise trauma, maximise patient comfort and for ease of use. Accurate manufacturing using high quality materials and excellent design helps to ensure maximum safety in our tracheostomy tubes. All Tracheosoft™ tubes are made from soft thermosensitive material and have flexible shapes. The large low-pressure, thin-walled cuff presents features that ensure a seal at low cuff pressures avoiding complications due to tracheal mucosal damage. Some products in the Tracheosoft™ tube range are fitted with the Lanz™ system, which actively regulates cuff pressure and prevents tracheal damage by compensating for both increases and decreases in cuff pressures. Innovation in cuff technology enables us to offer you the NEW SealGuard™ cuff technology. SealGuard™ is an ultra-thin strong polyurethane material that allows sealing at lower cuff pressures and through the reduced channelling effect, has potential to reduce Ventilator Associated Pneumonia.1 Patients with full or thick necks as well as those with long tracheal anatomies, tracheal stenosis or malacia may require extra-long tracheostomy tubes in order to achieve a proper fit. With extra length in the proximal or distal portions the Tracheosoft™ XLT tube accomodates different anatomical challenges. References: 1 Poelaert J, Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: a pilot. study; J Thorac Cardiovasc Surg. 2008 Apr;135(4):771-6 10 Tracheostomy Catalogue Tracheosoft™ Standard Standard tracheostomy tubes Pack includes: ATracheosoft™ standard tracheostomy tube with HI-LO™ cuff. BTracheosoft™ standard tracheostomy tube with HI-LO™ cuff and Lanz™ system for automatic cuff pressure regulation. CTracheosoft™ standard tracheostomy tube with adjustable flange and HI-LO™ cuff. DTracheosoft™ standard tracheostomy tube with adjustable flange, HI-LO™ cuff and Lanz™ system for automatic cuff pressure regulation. Further set components: a Obturator to facilitate insertion. not illustrated: fixation tape Ordering information: REF A B 138-50 138-60 139-60 138-70 139-70 138-75 139-75 138-80 139-80 138-85 139-85 138-90 139-90 138-10 139-10 Carton Quantity: 10 I.D. (mm) 5,0 6,0 7,0 7,5 8,0 8,5 9,0 10,0 O.D. (mm) 7,0 8,3 9,6 10,3 11,0 11,6 12,3 13,3 Length (mm) 45 54 65 70 76 82 89 97 Cuff Ø (mm) 19 21 23 24 26 28 30 33 REF I.D. O.D. Length Cuff Ø C D (mm) (mm) (mm) (mm) 100-50-1 101-50-1 5.0 7.0 72 19 100-60-1 101-60-1 6.0 8.3 81 21 100-70-1 101-70-1 7.0 9.6 90 27 100-80-1 101-80-1 8.0 10.9 94 31 100-90-1 101-90-1 9.0 12.3 99 34 100-10-1 101-10-1 10.0 13.3 110 34 Carton Quantity: 10 Tracheosoft™ tracheostomy tubes are single packed and sterile. 11 SealGuard™ Silent aspiration causes the most concern with regard to Ventilator Associated Pneumonia (VAP) in long-term intubated patients. Conventional cuffs are often overinflated for appropriate tracheal sealing. SealGuard™ tubes are different! The New Generation of SealGuard™ tubes with its ultra-thin cuff wall and the new tapered cuff sealing philosophy is designed to solve these issues. SealGuard™ tube in combination with EVAC helps to prevent early and late onset of Ventilator Associated Pneumonia.1, 2 With the new generation of SealGuard™ tracheal and tracheostomy tubes, Covidien presents a unique solution to intubation-related complications. The New Generation of SealGuard™ tube – a milestone for future Airway Management. References: 1 Lorente L.. Influence of an Endotracheal Tube with Polyurethane Cuff and Subglottic Drainage on Pneumonia. Am J Respir Crit Care Med, 2007 Sep 13 2 Poelaert J, Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: a pilot. study; J Thorac Cardiovasc Surg. 2008 Apr;135(4):771-6 12 Special functional cuff design for better sealing performance. Tracheostomy Catalogue EVAC concept One of the major causes of bronchopulmonary infections in patients undergoing long-term ventilation is aspiration from the subglottic space. Drainage of the subglottic space can significantly reduce the risk of infection in the airway during prolonged ventilation. Several scientific studies have demonstrated that regular drainage of the subglottic space using the HI-LO EVAC™ tube can reduce the incidence of Nosocomial Pneumonia in the ICU during prolonged intubation by as much as 50%.3 HI-LO EVAC™ Tracheostomy tubes are equipped with an additional lumen for improved access to the subglottic space. The lumen is integrated into the wall of the tracheostomy tube ending in a dorsal opening, proximal to the cuff. It allows suctioning of the subglottic space and the simple and rapid removal of secretions from this critical area. The additional lumen can be connected to a continuous or intermittent suction device to allow automatic suctioning of the subglottic space. If you require further information regarding the use of this prevention strategy or if you should require copies of scientific studies, please contact your Covidien representative. 3 Smulders K.,A Randomized Clinical Trial of Intermittent Subglottic Secretion Drainage in Patients Receiving Mechanical Ventilation; CHEST 2002; 121:858–862 13 Lanz™ System Automatically controls and limits cuff pressure for the entire duration of intubation and ventilation It is good practice to monitor cuff pressure to prevent tracheal complications in all patients with a cuffed tube. The Lanz™ system is designed to regulate cuff pressure automatically to minimise the risk of mucosal damage.1 Features and benefits: How does the Lanz™ System work? 1. A syringe is used to fill the Lanz™ system with •The Lanz™ external pilot balloon and the about 40 ml of air. Following this procedure adjustment valve continually regulate cuff cuff pressure will reach 30 - 34 cm H2O. pressure and prevent over or under inflation. mm Hg 2. A fter removing the syringe, the system •The automatically maintains cuff pressure below 34 cm H2O. 3. The special built-in control valve automatically 120external pilot balloon provides immediate 100 confirmation of cuff inflation. visual 80 60 •The40Lanz™ system eliminates manual control 20 Lanz of tracheal5tube10cuff pressure (although this is60 ml 20 30 40 50 always possible) if necessary. regulates pressure in the cuff and the Lanz™ pilot balloon. •Maintains Syringes or pressure gauges must not be connected permanently to the Lanz™ System; otherwise it will not function correctly. safe cuff pressure at different altitudes during air transport. •The Lanz™ system is permanently bonded into the tube to avoid the risk of disconnection. The Lanz tube compared with four other tracheal tubes without automatiche pressure regulation. mm Hg 120 100 80 60 40 20 A 5 14 10 Lanz 20 B 30 40 50 60 ml A C References: 1. Abud TM; The Lanz endotracheal tube decreases tracheal injury in dogs; Can J Anaesth. 2005 Oct;52(8):878-82 Tracheostomy Catalogue Tracheosoft™ Reinforced Tracheostomy tubes with HI-LO™ or SealGuard™ cuff Pack includes: ATracheosoft™ reinforced tracheostomy tube with adjustable flange and HI-LO™ cuff. BTracheosoft™ reinforced tracheostomy tube with adjustable flange, HI-LO™ cuff and Lanz™ system for automatic cuff pressure regulation. CSealGuard™ reinforced Tracheosoft™ tracheostomy tube with adjustable flange and ultra thin cuff. Further set components: a Obturator to facilitate insertion. not illustrated: fixation tape Ordering information: REF I.D. O.D. A B C (mm) (mm) 135-60 136-60 135860 6,0 8,3 135-70 136-70 135870 7,0 9,6 135-80 136-80 135880 8,0 10,9 135-90 136-90 135890 9,0 12,2 135-10 136-10 135810 10,0 13,6 135-11 136-11 135811 11,0 14,9 Carton Quantity: 10 Tracheosoft™ tracheostomy tubes are single packed and sterile. MAX Length (mm) 92 93 95 106 112 115 Cuff HI-LO version Ø (mm) 23 28 31 34 35 35 Cuff SealGuard™ version Ø (mm) 20 22 24 26 29 31 C 15 Tracheosoft™ EVAC & Pitt™ EVAC & Pitt™ tracheostomy tubes with HI-LO™ or SealGuard™ cuff Pack includes: ATracheosoft™ EVAC tracheostomy tube with HI-LO™ cuff and additional lumen for suctioning of subglottic secretions. BTracheosoft™ EVAC tracheostomy tube with HI-LO™ cuff and Lanz™ system for automatic cuff pressure regulation and additional lumen for suctioning of subglottic secretions. CTracheosoft Pitt™ speaking tube with HI-LO™ cuff and additional lumen for supplying air required for phonation. DTracheosoft™ EVAC tracheostomy tube with SealGuard™ cuff and additional lumen for suction of supra-glottic secretions. Further set components: a Obturator to facilitate insertion. not illustrated: fixation tape D Ordering information: REF I.D. O.D. A B C D (mm) (mm) 313-60 314-60 112-60 313860 6,0 8,3 313-70 314-70 112-70 313870 7,0 9,7 313-80 314-80 112-80 313880 8,0 11,0 313-90 314-90 112-90 313890 9,0 12,3 313-10 314-10 112-10 313810 10,0 13,7 Carton Quantity: 10 Tracheosoft™ tracheostomy tubes are single packed and sterile. 16 Length (mm) 77 80 91 92 100 Cuff HI-LO version Ø (mm) 23 27 31 34 35 Cuff SealGuard™ version Ø (mm) 20 22 24 26 29 Tracheostomy Catalogue Tracheosoft™ PERC™ PERC™ tracheostomy tubes, with HI-LO™ or SealGuard™ cuff tapered tip Pack includes: For use in percutaneous dilatational tracheostomy as per Ciaglia ATracheosoft™ PERC™ standard tracheostomy tube with HI-LO™ cuff. BTracheosoft™ PERC™ reinforced tracheostomy tube with adjustable flange and HI-LO™ cuff. CTracheosoft™ PERC™ reinforced tracheostomy tube with adjustable flange, HI-LO™ cuff and Lanz™ system for automatic cuff pressure regulation. DTracheosoft™ PERC™ reinforced tracheostomy tube with adjustable flange and SealGuard™ cuff. Further set components: a Obturator to facilitate insertion. not illustrated: fixation tape D Ordering information: REF I.D. O.D. Length A 134-80 134-90 Carton Quantity: 10 (mm) 8,0 9,3 (mm) 11,6 13,3 (mm) 81 97 REF I.D. O.D. B C D (mm) (mm) 137-80 1371-80 137880 8,0 11,7 137-90 1371-90 137890 9,3 13,6 Carton Quantity: 10 Tracheosoft™ tracheostomy tubes are single packed and sterile. Cuff Ø HI-LO version Ø (mm) 28 33 MAX Length (mm) 98 98 Cuff HI-LO version Ø (mm) 32 34 Cuff SealGuard™ version Ø (mm) 24 27 17 Tracheosoft™ XLT Extra-long flexible tracheostomy tube with disposable inner cannula PACK INCLUDES (DEPENDING ON VERSION): •Choice of distal or proximal extensions to fit unusual anatomies. •Flexible inner and outer cannula further improve fit. •High-volume, low-pressure cuff meets all published cuff criteria. •Extended-Length, Cuffless Tracheostomy Tube with extra length in proximal portion. •Extended-Length, Cuffed Tracheostomy Tube with extra length in proximal portion. •Extended-Length, Cuffless Tracheostomy Tube with extra length in distal portion. •Extended-Length, Cuffed Trachesotomy Tube with extra length in distal portion. •Extended-Length, Disposable Inner Cannula with integral 15 mm twist-lock connector. •Smooth, rounded-tip obturator facilitates insertion. Full or thick neck, choose Shiley™ Tracheosoft™ XLT tube with proximal extension (XLTCP or XLTUP). Long tracheal anatomies, tracheal stenosis or malacia, choose Shiley™ Tracheosoft™ XLT tube with distal extension (XLTCD or XLTUD). 18 Tracheostomy Catalogue Ordering information: REF I.D. (mm) O.D. (mm) Total Proximal Radial Distal Length Length Length Length (mm) (mm) (mm) (mm) Shiley™ Tracheosoft™ XLT Cuffed tracheostomy tube- Extended distal 50XLTCD 5,0 9,6 90 5 37 48 60XLTCD 6,0 11,0 95 8 38 49 70XLTCD 7,0 12,3 100 12 39 49 80XLTCD 8,0 13,3 105 15 40 50 Shiley™ Tracheosoft™XLT Uncuffed tracheostomy tube- Extended distal 50XLTUD 5,0 9,6 90 5 37 48 60XLTUD 6,0 11,0 95 8 38 49 70XLTUD 7,0 12,3 100 12 39 49 80XLTUD 8,0 13,3 105 15 40 50 Shiley™ Tracheosoft™ XLT Cuffed tracheostomy tube- Extended proximal 50XLTCP 5,0 9,6 90 20 37 33 60XLTCP 6,0 11,0 95 23 38 34 70XLTCP 7,0 12,3 100 27 39 34 80XLTCP 8,0 13,3 105 30 40 35 Shiley™ Tracheosoft™ XLT Uncuffed tracheostomy tube- Extended proximal 50XLTUP 5,0 9,6 90 20 37 33 60XLTUP 6,0 11,0 95 23 38 34 70XLTUP 7,0 12,3 100 27 39 34 80XLTUP 8,0 13,3 105 30 40 35 Cuff Ø (mm) Pack Quantity 29 31 35 35 1 1 1 1 29 31 35 35 1 1 1 1 29 31 35 35 1 1 1 1 29 31 35 35 1 1 1 1 How to measure. This diagram illustrates how the proximal, radial and distal measurements are determined for proper sizing. REF I.D. Pack / Quantity (mm) Shiley™ Tracheosoft™ XLT Replacement inner cannula 50XLTIN 5,0 10 60XLTIN 6,0 10 70XLTIN 7,0 10 80XLTIN 8,0 10 Tracheosoft™ tracheostomy tubes are single packed and sterile. 19 Argyle™ Silicone Tracheostomy tubes with cuff, in pure silicon •In pure, non-reactive, non-adherent silicon to minimise tissue irritation and mucous trauma and reduce the accumulation of secretions. •Radio-opaque. •Flexible •Pilot connected collar for greater security and comfort. balloon in pure silicon, pressure-sensitive, with positive Ordering information: seal valve. •Soft REF tip. •Silicon cuff adhering to the tube for easier insertion or removal •Conformity •Includes to ISO standards. a swivel connector (15 mm), obturator, two tracheostomy linings, fixation tape. Description 8888242008 Version with Cuff 8888242016 Version with Cuff 8888242024 Version with Cuff 8888242032 Version with Cuff 8888242040 Version with Cuff 8888242057 Version with Cuff Carton Quantity: 5 Argyle™ Silicone Paediatric tracheostomy tubes without cuff, in pure silicon •In pure, non-reactive, non-adherent silicon. •Radio-opaque. •Anatomical curvature with bevelled soft tip for easy tracheal insertion. •Soft tip. •Flexible connected collar for greater security and comfort. •Conformity •Includes to ISO standards. a thin-walled swivel connector (15 mm), tracheostomy tissue lining, fixation tape. 20 Ordering information: REF Description Paediatric version without cuff Paediatric version 8888241026 without cuff Paediatric version 8888241034 without cuff Paediatric version 8888241042 without cuff Paediatric version 8888241059 without cuff Paediatric version 8888241067 without cuff Paediatric version 8888241075 without cuff Paediatric version 8888241083 without cuff Carton Quantity: 5 8888241018 I.D. (mm) O.D. (mm) Length (mm) 2,5 4,0 31,0 3,0 4,7 32,0 3,5 5,4 34,0 4,0 6,0 36,0 4,5 6,6 40,0 5,0 7,3 46,0 5,5 7,8 50,0 6,0 8,5 54,0 I.D. (mm) 5,0 6,0 7,0 8,0 9,0 9,5 O.D. (mm) 7,3 8,7 10,0 11,0 12,3 13,3 Length (mm) 52,0 62,0 65,0 68,0 78,0 83,0 Tracheostomy Catalogue TLT kit Procedure kit for translaryngeal tracheostomy Content of the kit: 1 Rigid tracheoscope with cuff. 2 Tube extension. 3 Needle for initial puncture. 4 Flexible guide wire (J-Guide). 5 TLT tracheal tube, extra long. 6Reinforced tracheostomy tube with integrated dilator, angeled or straight. 7 Inflation line for cuff. 8 Handle for extraction. 9 Scalpel. 10 Obturator. 11 Neck flange for fixation. 12 15 mm connector. 13 Neck band. Ordering information: REF Size of tube angled tube straight tube size (mm) 403/10151 403/10178 9,5 403/10149 403/10177 8,5 403/10147 7,5 403/10145 6,5 403/10143 5,5 Carton quantity: 1 single sterile packed, for single use only ID (mm) 9,5 8,5 7,5 6,5 5,5 OD (mm) 12,1 11,2 10,2 8,7 7,3 Length (mm) 157 157 147 131 123 21 Accessories A Stoma Pad B Necktape IAnatomical fixation tape with comfortable securing system Polyurethane tracheostomy pad. C Necktape IIStandard fixation tape with adjustable securing system. D Necktape IIIAnatomical, comfortable fixation tape with double adjustable and adjustable closure. closure in two parts. E TTH Tracheostomy tube holder in two parts. F Tracheolife™ IIHME with O2 and suction port for spontaneously breathing G Hygrolife™ II H Swivel connectordouble swivel connector with access for bronchoscopy and A B C D E F G H patients. HME with CO2 sampling port for use with ventilated patients. tracheobronchial suction, sterile. I HI-LO™ hand pressure gauge (not sterile). For cuff inflation and cuff pressure measurement/adjustment Ordering information: REF 340 320-01 320-05 321-01 321-05 322 TTH 353/19004 353S19007 109-02 109-05 610/5257 Description Stoma Pad Necktape I, small Necktape I, large Necktape II, small Necktape II, large Necktape III Tracheostomy tube holder Tracheolife™ II Hygrolife™ II HI-LO™ hand pressure gauge Connection line for HI-LO™ hand pressure gauge Swivel connector Unit of sales 25 10 10 10 10 10 10 25 25 1 10 10 I 22 Tracheostomy Catalogue Accessories aDisposable inner cannula (DIC) with snap-lock 15 mm connector for use with DCT, DFEN, DCFS and DCFN tubes. bFenestrated disposable inner cannula (DICFEN) with 15mm snap-lock connector for use with DFEN and DCFN tubes. cSpare inner cannula (SIC) with 15 mm twist-lock connector for temporary use with LPC, FEN, CFS and CFN tubes, e.g. during cleaning of reusable inner cannula. dDecannulation plug (DCP) for use with FEN and CFN cannulae. eDecannulation plug (DDCP) for use with DFEN, DCFS and DCFN tubes. fCap (CAP) for use on reusable fenestrated inner cannulae of FEN and CFN cannulae. gShiley™ speaking valve (SSV) with silicone diaphragm. hShiley™ speaking valve (SSVO) with silicone diaphragm and integral O2 port. Ordering information: REF Size 4DIC 4 6DIC 6 8DIC 8 10DIC 10 4DICFEN 6DICFEN 8DICFEN 10DICFEN 4 6 8 10 4SIC 4 6SIC 6 8SIC 8 10SIC 10 For use with 4DCT, 4DFEN, 4DCFS, 4DCFN 6DCT, 6DFEN, 6DCFS, 6DCFN 8DCT, 8DFEN, 8DCFS, 8DCFN 10DCT, 10DFEN, 10DCFS, 10DCFN 4DFEN, 4DCFN 6DFEN, 6DCFN 8DFEN, 8DCFN 10DFEN, 10DCFN 4LPC, 4FEN, 4CFS, 4CFN 6LPC, 6FEN, 6CFS, 6CFN 8LPC, 8FEN, 8CFS, 8CFN 10LPC, 10FEN, 10CFS, 10CFN Unit of sales 10 10 10 10 10 10 10 10 REF 4DCP 6DCP 8DCP 10DCP DDCP CAP SSV SSVO Size 4 6 8 10 For use with 4FEN, 4CFN 6FEN, 6CFN 8FEN, 8CFN 10FEN, 10CFN DCFS, DCFN and DFEN Any size cannulae Any size FEN and CFN cannulae Any cannula with 15 mm connector Any cannula with 15 mm connector Unit of sales 10 10 10 10 10 10 2 2 10 10 10 10 23 Content in numerical order: REF Page REF Page REF Page REF Page REF Page REF Page REF Page 322 . . . . . . . . . . . 22 100-70-1 . . . . . . . 11 134-80. . . . . . . . . 17 139-90. . . . . . . . . 11 403/10175. . . . . . 21 6.0PLC. . . . . . . . . . 9 80XLTUD . . . . . . . 19 340 . . . . . . . . . . . 22 100-80-1 . . . . . . . 11 134-90. . . . . . . . . 17 3.0NEO . . . . . . . . . 9 403/10176. . . . . . 21 6.5PDL. . . . . . . . . . 9 80XLTUP. . . . . . . . 19 135810. . . . . . . . . 15 100-90-1 . . . . . . . 11 135-10. . . . . . . . . 15 3.0PED . . . . . . . . . 9 403/10177. . . . . . 21 6.5PLC. . . . . . . . . . 9 8CFN . . . . . . . . . . . 8 135811. . . . . . . . . 15 101-10-1 . . . . . . . 11 135-11. . . . . . . . . 15 3.5NEO . . . . . . . . . 9 403/10178. . . . . . 21 60XLTCD . . . . . . . 19 8CFS. . . . . . . . . . . . 8 135860. . . . . . . . . 15 101-50-1 . . . . . . . 11 135-60. . . . . . . . . 15 3.5PED . . . . . . . . . 9 4CFN . . . . . . . . . . . 8 60XLTCP. . . . . . . . 19 8DCFN. . . . . . . . . . 6 135870. . . . . . . . . 15 101-60-1 . . . . . . . 11 135-70. . . . . . . . . 15 313-10. . . . . . . . . 16 4CFS. . . . . . . . . . . . 8 60XLTIN. . . . . . . . 19 8DCFS . . . . . . . . . . 6 135880. . . . . . . . . 15 101-70-1 . . . . . . . 11 135-80. . . . . . . . . 15 313-60. . . . . . . . . 16 4DCFN. . . . . . . . . . 6 60XLTUD . . . . . . . 19 8DCP. . . . . . . . . . 23 135890. . . . . . . . . 15 101-80-1 . . . . . . . 11 135-90. . . . . . . . . 15 313-70. . . . . . . . . 16 4DCFS . . . . . . . . . . 6 60XLTUP. . . . . . . . 19 8DCT . . . . . . . . . . . 5 137880 . . . . . . . . 17 101-90-1 . . . . . . . 11 136-10. . . . . . . . . 15 313-80. . . . . . . . . 16 4DCP. . . . . . . . . . 23 610/5257. . . . . . . 22 8DFEN. . . . . . . . . . 5 137890 . . . . . . . . 17 109-02 . . . . . . . . 22 136-11. . . . . . . . . 15 313-90. . . . . . . . . 16 4DCT . . . . . . . . . . . 5 6CFN . . . . . . . . . . . 8 8DIC. . . . . . . . . . . . 5 313810. . . . . . . . . 16 109-05 . . . . . . . . 22 136-60. . . . . . . . . 15 314-10. . . . . . . . . 16 4DFEN. . . . . . . . . . 5 6CFS. . . . . . . . . . . . 8 8DIC. . . . . . . . . . . . 6 313860 . . . . . . . . 16 10CFN . . . . . . . . . . 8 136-70. . . . . . . . . 15 314-60. . . . . . . . . 16 4DIC. . . . . . . . . . . . 5 6DCFN. . . . . . . . . . 6 8DIC. . . . . . . . . . . 23 313870 . . . . . . . . 16 10CFS . . . . . . . . . . 8 136-80. . . . . . . . . 15 314-70. . . . . . . . . 16 4DIC. . . . . . . . . . . . 6 6DCFS . . . . . . . . . . 6 8DICFEN. . . . . . . . 23 313880 . . . . . . . . 16 10DCFN . . . . . . . . . 6 136-90. . . . . . . . . 15 314-80. . . . . . . . . 16 4DIC. . . . . . . . . . . 23 6DCP. . . . . . . . . . 23 8FEN . . . . . . . . . . . 7 313890 . . . . . . . . 16 10DCFS . . . . . . . . . 6 1371-80. . . . . . . . 17 314-90. . . . . . . . . 16 4DICFEN. . . . . . . . 23 6DCT . . . . . . . . . . . 5 8LGT . . . . . . . . . . . 8 8888241018 . . . . 20 10DCP. . . . . . . . . 23 1371-90. . . . . . . . 17 320-01. . . . . . . . . 22 4FEN . . . . . . . . . . . 7 6DFEN. . . . . . . . . . 5 8LPC. . . . . . . . . . . . 7 8888241026 . . . . 20 10DCP. . . . . . . . . 23 137-80. . . . . . . . . 17 320-05. . . . . . . . . 22 4LPC. . . . . . . . . . . . 7 6DIC. . . . . . . . . . . . 5 8PERC . . . . . . . . . . 5 8888241034 . . . . 20 10DCT . . . . . . . . . . 5 137-90. . . . . . . . . 17 321-01. . . . . . . . . 22 4SIC. . . . . . . . . . . 23 6DIC. . . . . . . . . . . 23 8SIC. . . . . . . . . . . 23 8888241042 . . . . 20 10DFEN. . . . . . . . . 5 138-10. . . . . . . . . 11 321-05. . . . . . . . . 22 5.0PDC. . . . . . . . . . 9 6DICFEN. . . . . . . . 23 CAP. . . . . . . . . . . 23 8888241059 . . . . 20 10DIC. . . . . . . . . . . 5 138-50. . . . . . . . . 11 353/19004. . . . . . 22 5.0PDL. . . . . . . . . . 9 6FEN . . . . . . . . . . . 7 DDCP. . . . . . . . . . 23 8888241067 . . . . 20 10DIC. . . . . . . . . . . 6 138-60. . . . . . . . . 11 353S19007. . . . . . 22 5.0PED. . . . . . . . . . 9 6LGT . . . . . . . . . . . 8 SSV. . . . . . . . . . . . 23 8888241075 . . . . 20 10DIC. . . . . . . . . . 23 138-70. . . . . . . . . 11 4.0NEO. . . . . . . . . . 9 5.0PLC. . . . . . . . . . 9 6LPC. . . . . . . . . . . . 7 SSVO . . . . . . . . . . 23 8888241083. . . . . 20 10DICFEN. . . . . . . 23 138-75. . . . . . . . . 11 4.0PDC. . . . . . . . . . 9 5.5PDC. . . . . . . . . . 9 6PERC . . . . . . . . . . 5 TTH . . . . . . . . . . . 22 8888242008 . . . . 20 10FEN . . . . . . . . . . 7 138-80. . . . . . . . . 11 4.0PED. . . . . . . . . . 9 5.5PDL. . . . . . . . . . 9 6SIC. . . . . . . . . . . 23 8888242016 . . . . 20 10LGT . . . . . . . . . . 8 138-85. . . . . . . . . 11 4.5NEO. . . . . . . . . . 9 5.5PED. . . . . . . . . . 9 70XLTCD . . . . . . . 19 8888242024 . . . . 20 10LPC. . . . . . . . . . . 7 138-90. . . . . . . . . 11 4.5PDC. . . . . . . . . . 9 5.5PLC. . . . . . . . . . 9 70XLTCP. . . . . . . . 19 8888242032. . . . . 20 10SIC. . . . . . . . . . 23 139-10. . . . . . . . . 11 4.5PED. . . . . . . . . . 9 50XLTCD . . . . . . . 19 70XLTIN. . . . . . . . 19 8888242040 . . . . 20 112-10. . . . . . . . . 16 139-60. . . . . . . . . 11 403/10143. . . . . . 21 50XLTCP. . . . . . . . 19 70XLTUD . . . . . . . 19 8888242057 . . . . 20 112-60. . . . . . . . . 16 139-70. . . . . . . . . 11 403/10145. . . . . . 21 50XLTIN. . . . . . . . 19 70XLTUP. . . . . . . . 19 100-10-1 . . . . . . . 11 112-70. . . . . . . . . 16 139-75. . . . . . . . . 11 403/10147. . . . . . 21 50XLTUD . . . . . . . 19 80XLTCD . . . . . . . 19 100-50-1 . . . . . . . 11 112-80. . . . . . . . . 16 139-80. . . . . . . . . 11 403/10149. . . . . . 21 50XLTUP. . . . . . . . 19 80XLTCP. . . . . . . . 19 100-60-1 . . . . . . . 11 112-90. . . . . . . . . 16 139-85. . . . . . . . . 11 403/10151. . . . . . 21 6.0PDL. . . . . . . . . . 9 80XLTIN. . . . . . . . 19 24 Tracheostomy Catalogue Notes 25 26 Tracheostomy Catalogue 27 COVIDIEN, COVIDIEN with Logo and TM marked brands are trademarks of Covidien AG or an affiliate. ©2008 Covidien. All rights reserved. Photos on pages 1 and 2: © Getty Images C-AN-UKTR1/GB - 12/2008 Covidien (UK) Commercial Ltd 154 Fareham Road Gosport Hampshire PO 13 OAS United Kingdom (UK) +44 (0) 1329 224226 [t] +44 (0) 1329 224334 [f] www.covidien.com
Similar documents
Shiley™ Tracheostomy Products Quick Reference Guide
1C. Tracheostomy Tube Cuffed with Disposable Inner Cannula (DCT) provides the convenience of a disposable inner cannula for a wide variety of applications. 1B. Tracheostomy Tube Cuffed with Dispo...
More information