VisualSonics
Transcription
VisualSonics
VisualSonics The Vevo® 770 MicroUltrasound System 進階生物科技 產品專員 張昕淳 V1.0 Presentation Overview • Introduction to VisualSonics Vevo system • Understanding Ultrasound for Preclinical Imaging • Overview of Key Research Areas Cancer Imaging Developmental Biology Abdominal & Reproductive Imaging Cardiovascular Research Other Species One Platform, Multiple Applications ImageGuided Techniques Anatomical Functional/ Physiological Contrast Benefits of High-Resolution Micro-Ultrasound • High Spatial Resolution Down to 30 microns • Real-Time • Non-Invasive Same animal imaged longitudinally as its own control • High throughput screening and quantification • Detailed anatomical, functional, physiological and now molecular analysis Total Small Animal Solution • Real-time • Longitudinal Studies • Measure Physiological parameters • Contrast/Molecular Imaging • Translatable to man RMV™ Scanhead , Rail & Physiological Monitoring System Interchangeable Mouse and Rat Handling Platforms Mouse Platform Rat Platform Anesthesia device Optimized Workflow Rapid Time-to-Results Step 1: Quick Imaging Set-Up Step 2: Real Time Visualization Step 3: Rapid Quantification How Ultrasound Works Simply Ultrasound Transducer • Sound with frequency > 30 MHz • Above human hearing Gel Area of interest Properties Medium Speed (m/s) Acoustic impedance (g/cm2x10^-5) Air 330 0.0004 Amniotic fluid 1510 1.51 Blood 1570 1.61 Bone 3500 7.8 Fat 1460 1.38 Liver 1550 1.65 Water 1480 1.48 •Ultrasound has difficulty penetrating bone. •Ultrasound waves do not pass through air. Ultrasound & Frequency Low Frequency Time High Frequency Time Higher Frequency = High Resolution = Lower Penetration Depth Clinical (human) scanners 2-13 MHz Small animal scanners up to 85 MHz Comparison of Human Fetus and Mouse Embryo in Utero 3 - 15 MHz Conventional clinical ultrasound (human fetus) 20cm Cantaloupe 30 – 80 MHz 3cm Coffee bean Micro ultrasound (mouse fetus) Conventional vs. Vevo® Imaging Cardiac – Short Axis (14 MHz Probe) (40 MHz Probe) Video Loops Conventional vs. Vevo® Imaging Cardiac – M-mode Septum/Anterior Wall Left Ventricle LV Posterior Wall Adapted Clinical System 13MHz Slide: Kimball, T., Cincinnati Children’s Hospital Image*: Zhou, YQ, Mouse Imaging Centre Dedicated Mouse System 30MHz Conventional vs. Vevo® Imaging Pulse Wave Doppler Conventional vs. Vevo® Imaging Intra-Observer Variability Clinical Clinical Vevo Vevo Analysis courtesy of Homma, S, Columbia U., 2005 Clinical Vevo Study involved complete cardio phenotyping with Vevo (30MHz) and Sequoia (13MHz) of 20 CD-1 mice (10x Normal, 10x myocardial infarction) Embryo through to adulthood Embryo Adult Phenotypic Screening from Embryonic Stage to Adulthood Video Loops Vevo MicroMarker Contrast Agents Exclusive Partnership: Bracco Group Joint development and manufacturing of MicroMarker™ kits Video Loop Targeted Microbubbles MicroMarker Target-Ready Microbubbles conjugated with antibody Microbubble PEG Layer Biotin Antibody` Antibody Streptavidin Adapted from N. Ferrara & R.S. Kerbel "Angiogenesis as a therapeutic target: advances and prospects." Nature, 438: 967-974, 2005 Cancer Imaging Subcutaneous Tumor – Blood Flow Regular Contrast Overlay MIP Contrast Overlay Cancer Imaging Subcutaneous Tumor – VEGFR2 Isotype Control Relative Expression of VEGFR2 in MeWo Tumor Model Change in Contrast Amplitude 1.2 1 0.8 0.6 0.4 0.2 0 VEGFR2 VEGFR2 Isotype Control Anteroapical Infarction in a Mouse (Short-Axis View) 10 min delayed Image sequence courtesy of Lindner, J., Oregon Health Sciences Centre, 2005 Color-coded enhancement Cancer Research • Screen for pre-palpable tumors • Quantification in 2D and 3D • Quantification in vascularity using Color Doppler Power Doppler Contrast Agents (MicroMarker) • Quantification of Biomarkers (VEGFR2, Integrins…) Cancer Imaging Orthotopic Tumor – B-Mode Imaging Pre-Palpable Tumor (60 mm3) Earliest Palpable Tumor (180 mm3) *Images and histology courtesy of Dr. Marris & Nick Rhodin, Children's Hospital of Philadelphia Quantification of Pre-Palpable Mammary Tumors 1 mm *WAP-TAg Mouse Model Image courtesy of Cotarla I. and Furth, P., Lombardi Cancer Centre, Georgetown University Cancer Imaging Subcutaneous Tumor Cancer Imaging Subcutaneous Tumor – 3D Volume = 115.95mm2 Paper Review: 3D Ultrasound Imaging in Preclinical Studies of Prostate Cancer in Mice Images: Wirtzfeld et al., Cancer Research 65: 6337-6345, 2005 Cancer Imaging Subcutaneous Tumor – Blood Flow Color Doppler Power Doppler Cancer Imaging Subcutaneous Tumor – 3D Power Day 1 PV = 3.18% Image sequence courtesy of Hastie, Chambers, Lacefield and Fenster, Robarts Research Institute, London, 2005 Day 4 PV = 11.22% Cancer Imaging Subcutaneous Tumor – Blood Flow Volume = 115.72mm3, PA = 14.75% Cancer Imaging Subcutaneous Tumor – VEGFR2 Isotype Control PA = 12.29% VEGFR2 PA = 41.52% Paper Review: Self-destruction of Melanomas after Pulsed Electric Fields Day 0 Day 16 Before After Images: Nuccitelli et al., Biochemical and Biophysical Research Communications 343: 351-360, 2006 Poster Review (presented at AACR 2008): Visualization and Quantification of Relative Perfusion in 3D volume Cancer Imaging Transgenic Tumor – 3D Day 0 Volume = 9.86mm3 Day 5 Volume = 13.42mm3 Tumor images courtesy of Robarts Research Institute, 2008 Cancer Imaging Transgenic Tumor – Blood Flow Color Doppler Power Doppler Volume = 7.13mm3, PV=3.13% Tumor images courtesy of Robarts Research Institute, 2008 Cancer Imaging Transgenic Tumor – Blood Flow Tumor images courtesy of Robarts Research Institute, 2008 Cancer Imaging Collagen Plug – Blood Flow Contrast Intensity MicroMarker Bolus Wash-in Curve for Collagen Plug 60 50 40 30 20 12 13 14 15 16 Time (Sec) Images Courtesy of: Fortune Fry Micro-Ultrasound Core Indiana Center for Vascular Biology and Medicine IU School of Medicine (2007) 17 18 19 20 Cancer Imaging Matrigel – Blood Flow Growth Factor Images Courtesy of: M. Tjwa, Molecular Cardiology University of Frankfurt, 2008 No Growth Factor Cancer Imaging Matrigel – Blood Flow Growth Factor Flow Growth Factor No Flow Untargeted Contrast Agent Matrigel Model Growth Factor - Flow Growth Factor - No Flow No Growth Factor No Growth Factor Contrast Intensity 100 80 60 40 20 0 13 14 15 16 17 Time (sec) Images Courtesy of: M. Tjwa, Molecular Cardiology University of Frankfurt, 2008 18 19 20 Cancer Imaging Image-Guided Needle Injection/Extraction Cancer Imaging Subcutaneous Tumor – Power Doppler Image sequence, mouse model and therapeutic courtesy of Cheung A., Brown AS, Cucevic V, Roy M, Yang V, Needles A, Hicklin DJ, Kerbel RS, Foster FS, Sunnybrook and Women’s CHSC and Imclone Systems Inc. Developmental Biology Embryonic Mouse Development at E7.5 Amniotic Cavity 1 mm Coelomic Cavity Atlas of Mouse Development, MH Kaufman Foster FS et al., Ultrasound in Med and Biol, 28:1165-1172, 2002 Ectoplacental Cavity Sagittal Profile at E12 Video Loop Quantification of Embryonic Valvular Function at E12.5 A B C D HR 280 bpm HR 281 bpm The ventricular septum, the dark region visible between the left and right ventricles, is forming but incomplete . View of heart (A, B) at 12.5 days. The division of the inflow tract is visible. Yellow boxes in (A) and (B) show sample volume locations for Doppler flow spectra from mitral orifice in (C) and from tricuspid orifice in (D). Images from Zhou YQ et al., Physiol Genomics 10:113-126, 2002; Illustration from Heart Development by Harvey and Rosenthal Injection into brain at E12 Video Loop Profile at E17 Video Loop Abdominal & Reproductive Imaging • • • • • Midline Abdominal Landmarks Adrenal Glands Kidney Pancreas Ovary Midline Abdominal Landmarks Video Loop Adrenal Gland Video Loops Mouse Left Kidney Video Loop Injection into the Kidney Video Loop Flow within the Mouse Pancreas Video Loops Ovary Imaging Video Loops Cardiovascular Research Long-axis EKV® Mode PSSA Normal vs. Infarct Video Loops Parasternal Long Axis View of Left Ventricle in Adult Mouse using EKV™ Normal Heart Image by VisualSonics Infarct Heart Video Loop Scale: mm Parasternal Short Axis Video Loops M-Mode Normal vs. Infarct Infarct Normal Infarct Image courtesy of Kovacs, A., Washington U., 2005 Normal Image by VisualSonics, 2006 Mitral Valve Doppler Video Loop High Aortic Velocity and Regurgitation Ao Doppler sample volume just above the aortic valves LV Aortic valves Doppler sample volume just beneath the aortic valves High aortic velocity over 2000mm/s Regurgitation Image by Yuqing Zhou, MICE Carotid Artery Video Loops Adult Cardiac Injection Plaque Build-up in Carotid Arteries in Adult Mouse 1 mm 10 w ApoE/LDLr DKO mouse CCA Image sequence courtesy of Gan et al, University of Gothenburg, Sweden 40 w ApoE/LDLr DKO mouse CCA 80 w ApoE/LDLr DKO mouse CCA Other Species… Chick Embryo Zebra Fish Axolotl Salamander Goby Fish Finch Egg Advancing preclinical research 3080 yonge street suite 6100 box 66 toronto canada M4N 3N1 WEBSITE > www.visualsonics.com TOLL FREE (North America) > 1.866.416.4636 TOLL FREE (Europe) > + 800.0751.2020 Cardiovascular Cancer Developmental Biology Diabetes Neurobiology Reproductive Biology Regenerative Medicine Ophthalmology Molecular Imaging Orthopedic Elastography Gene Delivery
Similar documents
Flow Cytometer 原理(PDF)
FL 1 : (525 nm BP) for green dyes FL 2 : (575 nm BP) for yellow dyes FL 3 : (615 nm BP) for orange dyes FL 4 : (675 nm BP) for red dyes
More information