Industrial Catalogue

Transcription

Industrial Catalogue
DISEGNO OLC3105 INDUSTRIAL CATALOGUE COVER C M Y K PMS877 PMS REFLEX BLUE spot uv gloss
Australia Head Office 207 Sunshine Road Tottenham
Victoria 3012 Australia Phone 613 9281 4444
INDUSTRIAL
Cable Sales Phone 1300 CABLES
New Zealand Paraite Road Bell Block
New Plymouth New Zealand Phone 646 755 9800
www.olex.co.nz
South East Asia 401 Macpherson Road
#02-07 Hotel Windsor Singapore 368125
Phone 65 688 70200
China Room 5410 Building 4, Xiyuan Hotel
Beijing China 100044 Phone 86 10 6835 1019
For more information see
www.olex.com.au
LOW VOLTAGE
INDUSTRIAL
HIGH VOLTAGE
FIRE RATED
DATA/COMMS
MINING
a Nexans company
a Nexans company
INDUSTRIAL
World leader in indus
Olex has been designing and manufacturing cables
And now as part of the world’s largest cable manufacturer,
Nexans, Olex are able to provide an even greater range of
in Australia for over half a century delivering
specialised industrial cables for the demanding Australian market.
New to the Olex industrial offer is the Titanex ® range of
superior performance in design, quality engineering
flexible cables to complement the existing Olex range which
includes Powerlex,™ Versolex ® and Flexolex.®
excellence, distribution and customer service.
Contents
Introduction
Flexible Power Cable Selection Criteria
2
Flexible Power
3
Powerlex™ PVC Flexible Cords 4–5
Versolex® HD Single Core Power/Welding
6
Versolex® HD Unscreened Power/Submersible
7
Versolex® HD Braid Screen VSD/Submersible
8
Varolex® Copper Tape Screened VSD
9
NEW Titanex® H07RN-F Single Core
10
NEW Titanex® H07RN-F Multi Core
11
Flexolex® HD 2, 3, 4 & 5 Core Cords/Cables, Unscreened
12
Flexolex® HD-S 4 & 5 Core Cords/Cables, Screened
13
Flexolex® SP Single Core Power & Welding Cables
14
Technical Data – Flexible Conductors
15–16
Flexible Control & Specialist Applications
17
NEW Rheyflex Y PVC Flexible Control Cable
18
NEW Rheyflex YCY PVC–EMC Flexible Control Cable
19
PVC Flexible Drag Chain Cable
20
Robotics Cable
21
NEW H07VVH6-F PVC Flat Cable
22
NEW VCVH6-F Screened PVC Flat Cable
23
NEW Rheyflat®-N / NGFLGOEU-J Rubber Flat Festoon Cable 24
NEW Rheyflat®-N / (N)GFLCGOEU-J
Screened Rubber Flat Festoon Cable
25
NEW Boitalyon®R PVC Pendant Overhead Crane Cable
26
NEW Buflex® X’Prem Reeling Cable
27
NEW Rheyhalon NSHXAFOE EN
28
Silicone Single Core Cable Halogen Free
29
Silicone Multicore Cable Flexible Halogen Free
30
Stranding and Current Ratings
31
Bus Technology Cables
32–33
Current Carrying Capacity for
H07VVH6-F, HCVH6-F, Rheyflat®-N, Boitalyon®R
34
Bending Radius
34
trial cable
Also new to Olex is a comprehensive range of flexible control
and specialist application cables.
This catalogue represents our complete range of industrial cables.
For more information on any of these products, or for information
on any other Olex cables, visit www.olex.com.au.
Instrolex® Instrumentation
35
Instrument Cable Technology
Instrolex® Cable Construction
Instrolex® Cable Characteristics
Instrolex® Unscreened & Overall Screened Pairs
Instrolex® Individually & Overall Screened Pairs
Instrolex® Overall Screened SWA Pairs
Instrolex® Individually & Overall Screened SWA Pairs
Instrolex® Triples
The Olex Cable Range
36
37
38
39
40
41
42
43
44
Flexible Power Cable Selection Criteria
Flexibility
Operating Temperature
Doesn’t kink. Compact and lightweight
Withstands cold and heat, sustaining
for both fixed and flexible applications.
flexibility from –40 to +90°C.
Flexolex®
Flexolex®
Titanex
®
Titanex®
Versolex®
Versolex®
Powerlex™
Powerlex™
Water Immersion
Physical Toughness
Permanently submersible.
Durable and resistant to cut-through,
Water and moisture resistant.
crush and abrasion.
Flexolex®
Flexolex®
Titanex
®
Titanex®
Versolex
®
Versolex®
Powerlex™
Powerlex™
Oils/Fuels/Solvents
Acids/Bases
Resistant to a range of common oils
Resistant to a range of common acid
and solvents.
and alkaline chemicals.
Flexolex®
Flexolex®
Titanex®
Titanex®
®
Versolex
Versolex®
Powerlex™
Powerlex™
Heat Environment
Environmental Exposure
Flame retardant. Tested to IEC 60332.1
Resistant to ozone and UV.
and AS/NZS 1660.5.6.
Flexolex®
Flexolex®
Titanex
®
Titanex®
Versolex®
Versolex®
Powerlex™
Powerlex™
Electromagnetic Compatibility
Note Selection criteria graphs are
Screened range designed for
a guide only. For further data, please
applications with EMC requirements.
contact the Olex Technical Support
on 03 9281 4600.
2
Contents
Powerlex™ PVC Flexible Cords 4–5
Versolex® HD Single Core Power/Welding
6
Versolex® HD Unscreened Power/Submersible 7
Versolex® HD Braid Screen VSD/Submersible 8
Varolex® Copper Tape Screened VSD
9
NEW Titanex® H07RN-F Single Core
10
NEW Titanex® H07RN-F Multi Core
11
Flexolex® HD 2, 3, 4 & 5 Core Cords/Cables,
Unscreened
12
Flexolex® HD-S 4 & 5 Core Cords/Cables,
Screened
13
Flexolex® SP Single Core Power &
Welding Cables
14
Technical Data – Flexible Conductors
15–16
Flexible
Power
Olex offers flexibility in design and flexibility
in choice.
The addition of the Titanex ® range of H07 flexible single core
and multi-core cables to the Olex range means you can now source
the best value solution for any flexible power cable application,
all from one supplier.
So whether it be a simple PVC cord or an all purpose rubber flex,
Olex has the cable you need.
Now, more than ever, Olex is your flexible power cable specialist.
3
Powerlex PVC Flexible Cords
V90 Single Core
™
Construction 0.6/1kV, PVC insulated, flexible cord to AS/NZS 3191, copper conductors. Maximum 75°C continuous.
Nominal
conductor
area
Average
insulation
thickness
mm 2
mm
0.5
0.75
1.0
1.5
2.5
4.0
0.8
0.8
0.8
0.8
0.9
1.0
Nominal
Approximate
overall
mass
diameter mm
kg/100m 2.6
1.1
2.8
1.5
3.0
1.7
3.2
2
3.7
3
5.0
6
Product code
BAAR01AA001
BAAR02AA001
BAAR03AA001
BAAR04AA001
BAAR05AA001
BAAR06AA001
Note V-90HT available.
Powerlex PVC Flexible Cords
Light Duty 2 and 3 Core
™
Construction 250/250V, PVC insulated, PVC sheathed, flexible cord to AS/NZS 3191 and AS/NZS 60227,
copper conductors. Maximum 75°C continuous.
Number
of cores
2 Core
3 Core
Nominal
conductor
area
mm 2
0.75
0.75
Standard colours Refer page 6.
Technical data Refer pages 15 and 16.
INDUSTRIAL
4
Average insulation
thickness
mm
0.5
0.5
Average
sheath
thickness
mm
0.6
0.6
Nominal
overall
diameter
mm
5.7
5.8
Approx.
mass
kg/100m
5
6
Product code
CBER02AA002
EBER02AA003
Powerlex PVC Flexible Cords
Ordinary Duty 2, 3, 4 & 5 Core
™
Construction 250/440V, PVC insulated, PVC sheathed, flexible cord to AS/NZS 3191 and AS/NZS 60227,
copper conductors. Maximum 75°C continuous. Prescribed Article Approval No. V/1017.
Nominal
conductor
area
mm 2
2 Core
0.75
1.0
1.5
2.5
4.0
3 Core (2+E )
0.75
1.0
1.5
2.5
4.0
4 Core (3+E )
0.75
1.0
1.5
2.5
4.0
5 Core (4+E )
0.75
1.0
1.5
2.5
4.0
Product code
Average
insulation
thickness
mm
Average
sheath
thickness
mm
Nominal
overall
diameter
mm
Approx.
mass
0.6
0.6
0.7
0.8
0.8
0.8
0.8
0.8
1.0
1.0
6.3 6.6
7.6
9.4
10.5
6
7
9
14
19
CAHR02AA002
CAHR03AA002
CAHR04AA002
CAHR05AA002
CAHR06AA002
0.6
0.6
0.7
0.8
0.8
0.8
0.8
0.9
1.1
1.1
6.6
7.0
8.3
10.1
11.4
7
8
11
17
24
EAHR02AA003
EAHR03AA003
EAHR04AA003
EAHR05AA003
EAHR06AA003
0.6
0.6
0.7
0.8
0.8
0.8
0.9
1.0
1.1
1.1
7.2
7.8
9.2
11.0
12.4
8
10
14
21
29
GAHR02AA004
GAHR03AA004
GAHR04AA004
GAHR05AA004
GAHR06AA004
0.6
0.6
0.7
0.8
0.8
0.9
0.9
1.1
1.2
1.2
8.1
8.5
10.3
12.3
13.8
10
12
17
26
36
APAR02AA005
APAR03AA005
APAR04AA005
APAR05AA005
APAR06AA005
kg/100m
Standard colours Refer page 6.
Technical data Refer pages 15 and 16.
5
Versolex HD Single Core
Power/Welding
®
Construction 0.6/1kV cables, flexible XLPE insulated and TPE sheathed to AS/NZS 5000.1 and AS/NZS 1995,
copper conductors. Maximum 90°C continuous.
Nominal
conductor
area
mm 2
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
Maximum
diameter
of wires
mm
0.21
0.21
0.21
0.21
0.31
0.31
0.31
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
Nominal
overall diameter
mm
8.5
9.8
11.3
12.6
14.2
16.2
18.3
20.7
22.6
24.6
27.7
31.0
35.4
40.0
44.0
Approximate
mass
kg/100m
14.0
20.2
29.7
39.5
53.6
74.4
99.3
125
150
179
240
290
389
498
629
Product code
BDSX01AA001
BDSX02AA001
BDSX03AA001
BDSX04AA001
BDSX05AA001
BDSX06AA001
BDSX07AA001
BDSE87AA001
BDSE88AA001
BDSE89AA001
BDSE90AA001
BDSE91AA001
BDSE92AA001
BDSE93AA001
BDSE94AA001
Standard colours
Conductor size
All sizes
Single Core SDI 2 Core
≤4 mm 2
2 Core + Earth
≤4 mm 2
≥6 mm 2
3 Core + Earth
≤4 mm 2
3 Core + 3 Earth
≥6 mm 2
4 Core + Earth
≤4 mm 2
≥6 mm 2
INDUSTRIAL
6
Standard sheath colour (metre marked)
Orange
Black
Black
Black
Black
Black
Black
Black
Code
Insulation colours
Code
OM
CX
CX
CX
CX
CX
CX
CX
Natural
Brown, light blue
Brown, light blue, green/yellow
Red, black, green/yellow
Brown, white, light blue, green/yellow
Red, natural, blue, green/yellow
Brown, orange, white, light blue, green/yellow
Red, natural, blue, black, green/yellow
NA
JJ
KA
TD
SA
PF
SB
LR
Versolex HD Unscreened
Power/Submersible
®
Construction 0.6/1kV cords and cables, flexible XLPE insulated and TPE sheathed to AS/NZS 3191 (cords) and where
applicable AS/NZS 5000.1 (cables), copper conductors. Maximum 90°C continuous.
Nominal
conductor area
mm 2
2C
1
1.5
2.5
4
3C (2C+E)
1
1.5
2.5
4
6
4C (3C+E or 3C+3E)
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
5C (4C+E)
1
1.5
2.5
4
6
10
16
25
35
50
70
Approximate
mass
Product code
Maximum
diameter of wires
mm
Nominal
insulation
thickness
mm
Nom.
sheath
thickness
mm
Nominal
overall
diameter
mm
0.21
0.26
0.26
0.31
0.7
0.7
0.7
0.7
1.3
1.5
1.7
1.8
7.9
8.9
10.2
11.5
8
10
14
19
CFGR03AA002
CFGR04AA002
CFGR05AA002
CFGR06AA002
0.21
0.26
0.26
0.31
0.31
0.7
0.7
0.7
0.7
0.7
1.4
1.6
1.8
1.9
1.8
8.6
9.5
10.9
12.3
14.7
9
12
17
24
32
EFGR03AA003
EFGR04AA003
EFGR05AA003
EFGR06AA003
FEHR07AA003
0.21
0.26
0.26
0.31
0.31
0.21
0.21
0.21
0.21
0.31
0.31
0.31
0.51
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.9
0.9
1.0
1.1
1.1
1.2
1.5
1.7
1.9
2.0
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.2
2.2
9.4
10.5
12.0
13.5
14.5
16.6
18.9
22.1
25.4
28.2
33.1
37.4
41.3
11
15
21
29
33
48
71
105
144
200
268
363
442
GFGR03AA004
GFGR04AA004
GFGR05AA004
GFGR06AA004
FTAR07AA003
FTAX01AA003
FTAX02AA003
FTAX03AA003
FTAX04AA003
FTAX05AA003
FTAX06AA003
FTAX07AA003
FTAE87AA003
0.21
0.26
0.26
0.31
0.31
0.21
0.21
0.21
0.21
0.31
0.31
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.9
0.9
1.0
1.1
1.6
1.8
2.0
2.2
1.8
1.8
1.8
1.8
1.9
2.1
2.3
10.6
11.7
13.4
15.5
17.5
19.2
22.1
26.8
31.0
35.1
41.0
13
17
23
34
44
67
97
146
198
276
386
BWBR03AA005
BWBR04AA005
BWBR05AA005
BWBR06AA005
BWBR07AA005
BWBX01AA005
BWBX02AA005
BWBX03AA005
BWBX04AA005
BWBX05AA005
BWBX06AA005
kg/100m
Standard colours Refer page 6.
Technical data Refer pages 15 and 16.
7
Versolex HD Braid Screen
VSD/Submersible
®
Construction 0.6/1kV cables, flexible XLPE insulated, TPE bedded, copper wire braid screened, TPE sheathed to
AS/NZS 3191 (cords) and AS/NZS 5000.1 (cables) 3 earths, copper conductors. Maximum 90°C continuous.
For flexible application
Nominal
Maximum
conductor
diameter
area
of wires
mm 2
mm
4C (3C+E or 3C+3E)
1.5
0.26
2.5
0.26
4
0.31
6
0.31
10
0.21
16
0.21
25
0.21
35
0.21
50
0.31
70
0.31
95
0.31
120
0.50
150
0.50
185
0.50
240
0.50
300
0.50
5C (4C+E)
1.5
0.26
2.5
0.26
4
0.31
6
0.31
10
0.21
16
0.21
25
0.21
35
0.21
50
0.31
70
0.31
Approximate
mass
Product code
Nominal
insulation
thickness
mm
Combined
earth
size
mm
Nominal diameter Nominal
under
sheath
braid
thickness
mm
mm
Nominal
overall
diameter
mm
kg/100m
0.7
0.7
0.7
0.7
0.7
0.8
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
1.5
2.5
4.0
4.5
4.5
7.5
12
18
30
30
48
48
75
75
105
150
9.1
10.2
11.6
13.8
15.0
17.4
20.5
23.2
27.1
31.1
35.2
40.2
44.7
49.7
55.8
62.0
1.7
1.9
2.0
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.2
2.2
2.3
2.5
2.7
2.8
13.9
15.2
17.0
18.7
20.0
22.8
26.0
28.9
32.9
37.6
41.9
47.7
52.5
57.9
64.5
69.7
24
31
41
42
66
96
137
174
237
331
428
526
642
756
988
1206
GETR04AA004
GETR05AA004
GETR06AA004
FTTR07AA003
FTTX01AA003
FTTX02AA003
FTTX03AA003
FTTX04AA003
FTTX05AA003
FTTX06AA003
FTTX07AA003
FTTE87AA003
FTTE88AA003
FTTE89AA003
FTTE90AA003
FTTE91AA003
0.7
0.7
0.7
0.7
0.7
0.8
0.9
0.9
1.0
1.1
–
–
–
–
–
–
–
–
–
–
10.1
11.4
12.8
15.6
17.2
21.7
24.9
28.5
33.7
38.4
1.8
2.0
2.2
1.8
1.8
1.8
1.8
1.9
2.1
2.3
15.1
16.6
18.4
21.1
22.5
26.4
30.1
33.7
39.9
43.9
28
36
46
63
83
124
143
247
344
406
BWTR04AA005
BWTR05AA005
BWTR06AA005
BWTR07AA005
BWTX01AA005
BWTX02AA005
BWTX03AA005
BWTX04AA005
BWTX05AA005
BWTX06AA005
Standard colours Refer page 6. Technical data Refer pages 15 and 16.
Alco VSD Cable Gland
Bead chain
Metal screen
Body
Inner seal (C)
Neoprene seal (A or B)
Sleeve
Fibre washer
Gland nut
Applications
 Fixed (Varolex ®) or flexible (Versolex ®) cable
Thread dia.
Dim. OA
 Indoor or outdoor use
Function
 Provides seal on cable sheath
 Provides contact between screen and earth (body)
Approvals
INDUSTRIAL
 Degree of protection against ingress of water IP66/68 (30m)
 Complies with AS 1939–1990
8
Thread
length
Dim. Q
Dim. P
Gland length
Weatherproof gland for tape or braided
screened Variable Speed Drive (VSD) cable
Varolex Copper Tape
Screened VSD
®
Construction 0.6/1kV cables, XLPE insulated, fixed conductors, laid up with the three earths disposed in interstices
of the power cores, PVC bedded, collective copper tape screened and PVC sheathed, complying with AS/NZS 5000.1,
copper conductors. Maximum 90°C continuous.
For fixed application
Power cores
Nominal
conductor area
mm 2
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
Nominal
Combined
Nominal diameter
insulation
earth size
under screen
thickness
mm
mm
mm
0.7
2.5*
10.8
0.7
4.5 12.8
0.7
4.5
13.7
0.7
4.5
14.7
0.7
7.5
16.7
0.9
12
19.2
0.9
18
22.0
1.0
30
25.2
1.1
30
28.5
1.1
48
33.2
1.2
48
38.3
1.4
75
42.0
1.6
75
46.8
1.7
105
52.9
1.8
150
58.8
Nominal
overall diameter
Approximate
mass
mm
14.5
16.5
17.4
18.4
20.3
22.8
25.6
28.8
32.1
36.9
42.0
45.8
50.8
57.2
63.5
kg/100m
33
41
49
62
86
122
162
215
280
385
465
582
703
915
1153
Product code
FTDP07AA003
FTDP09AA003
FTDP11AA003
FTDP13AA003
FTDP15AA003
FTDC17AA003
FTDC18AA003
FTDC19AA003
FTDC20AA003
FTDC22AA003
FTDP23AA003
FTDP24AA003
FTDP25AA003
FTDP26AA003
FTDP27AA003
*Split earth not required, therefore a single earth conductor is utilised.
Standard colours
Power cores: Red, White, Blue. Earth cores: Green/Yellow. Sheath: Black.
Electrical data AS/NZS 3008.1.
Current ratings AS/NZS 3008.1.
Alco gland selection chart
Item
number
ALCEMC16
ALCEMC20
ALCEMC25
ALCEMC32
ALCEMC40
ALCEMC50
ALCEMC63
ALCEMC75A
ALCEMC75B
Mounting
Tightening
thread
torque
diameterlength
mm
Nm
M1612
9
M2012
13
M2512
21
M3212
34
M4015
53
M5015
83
M6319
132
M7519
188
M7519
188
Diameter
Gland length
Cable details
across
uncompressed compressed
Varolex ®
Versolex ® 4C
Versolex ® 5C
flats
product
product
product
mm
mm
mm
code
code
code
27.5
58
43
32.5
58
43
FTDP07,P09
GETR04,R05,R06 BWTR04,R05
37.5
61
45
FTDP11,* P13,P15 FTTR07,X01
BWTR07
37.5
62
46
FTDC17,C18
FTTX02,X03
BWTX01,X02
47.5
72
54
FTDC19,C20
FTTX04,X05
BWTX03,X04
57.5
80
60
FTDC22
FTTX06,X07
BWTX05
70
96
75
FTDP23,P24
FTTE87
BWTX06
85
105
80
FTDP25
FTTE88
85
111
83
FTDP26
FTTE89
PVC
shroud
(orange)
ALCSG2
ALCSG3
ALCSG3
ALCSG3
ALCSG5
ALCSG6
ALCSG7
9
Titanex H07RN-F
Single Core
®
Construction 0.6/1kV cables, cross-linked synthetic EPR rubber insulated and sheathed, lead free. Copper conductors
to DIN VDE 0295 class 5. Core identification to HD 308 S2.
Application Titanex® flexible cable is intended for installations with moving equipment, electric appliances and
for building sites. This cable can be installed in open air or buried (with extra mechanical protection).
Cross
section
mm 2
6
10
16
25
35
50
70
95
120
150
185
240
300
Perm. Current
rating open air
A
56
77
102
136
168
203
254
315
363
416
475
559
637
Min. outer
diameter
mm
7.9
9.5
10.8
12.7
14.3
16.5
18.6
20.8
22.8
25.2
27.6
30.6
33.5 Max. outer diameter
mm
9.8
11.9
13.4
15.8
17.9
20.6
23.3
26.0
28.6
31.4
34.4
38.3 41.9
Approx.
weight
kg/km
109
182
256
369
482
662
895
1164
1430
1740
2160
2730 3480
Marking
Cores identifications
1 core: Black (preferential)
USE<HAR>H07RN-F
2 cores: Brown+Blue
Nb X (ou G) S
3 cores: Green/Yellow+Blue+Brown (G)
TITANEX
Brown+Black+Grey (X S>4mm2)
X = without G/Y
Blue+Brown+Black (X S 1.5 & 2.5mm2)
G = with G/Y
4 cores: Green/Yellow+Brown+Black+Grey (G)
S = cross section (mm 2)
Blue+Brown+Black+Grey (X S 1.5 & 2.5mm2)
5 cores: Green/Yellow+Blue+Brown+Black+Grey
Standards
>5 cores: 1 Green/Yellow+the other Black (numbered)
International IEC 60245-4 type 66
Europe CENELEC HD 22-4
National NF C 32-102-4
INDUSTRIAL
Note Other sizes available upon request.
10
Product
code
HAR1X6
HAR1X10
HAR1X16
HAR1X25
HAR1X35
HAR1X50
HAR1X70
HAR1X95
HAR1X120
HAR1X150
HAR1X185
HAR1X240
HAR1X300
Titanex H07RN-F
Multi Core
®
Construction 0.6/1kV cables, cross-linked synthetic EPR rubber insulated and sheathed, lead free. Copper conductors
to DIN VDE 0295 class 5. Core identification to HD 308 S2.
Application Titanex® flexible cable is intended for installations with moving equipment, electric appliances and
for building sites. This cable can be installed in open air or buried (with extra mechanical protection).
No. cores &
cross-sec.
mm 2
2C
1
1.5
2.5
2C+E
1
1.5
2.5
4
6
3C+E
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
4C+E
1.5
2.5
4
6
10
16
25
35
6C+E
1.5
2.5
11C+E
1.5
2.5
18C+E
1.5
26C+E
1.5
35C+E
2.5
Perm. Current
rating open air
A
Approx.
weight
kg/km
Product
code
Min. outer
diameter
mm
Max. outer diameter
mm
18
23
32
7.7
8.5
10.2
10.0
11.0
13.1
99
111
161
HAR2X1
HAR2X1.5
HAR2X2.5
18
23
32
43
56
8.3
9.2
10.9
12.7
14.1
10.7
11.9
14.0
16.2
18.0
117
134
195
290
346
HAR3G1
HAR3G1.5
HAR3G2.5
HAR3G4
HAR3G6
16
21
29
38
50
68
92
122
150
182
232
281
325
9.6
10.2
12.5
14.0
15.7
20.8
23.8
28.9
32.5
37.7
42.7
48.4
53.0
12.0
13.1
15.5
18.0
20.0
26.5
30.1
36.6
41.1
47.5
54.0
61.0
66.0
144
165
245
357
443
818
1150
1700
2180
3030
3990
5360
6500
HAR4G1
HAR4G1.5
HAR4G2.5
HAR4G4
HAR4G6
HAR4G10
HAR4G16
HAR4G25
HAR4G35
HAR4G50
HAR4G70
HAR4G95
HAR4G120
21
29
38
50
68
92
122
168
11.2
13.3
15.6
17.5
22.9
26.4
32.0
35.8
14.4
17.0
19.9
22.2
29.1
33.3
40.4
45.1
238
297
453
557
1001
1430
2096
2770
HAR5G1.5
HAR5G2.5
HAR5G4
HAR5G6
HAR5G10
HAR5G16
HAR5G25
HAR5G35
15
21
14.7
17.1
18.7
22.0
365
490
HAR7G1.5
HAR7G2.5
11
15
17.6
20.6
22.1
26.2
510
676
HAR12G1.5
HAR12G2.5
9
20.9
26.5
765
HAR19G1.5
7
24.9
31.5
1015
HAR27G1.5
9
33.2
41.8
1862
HAR36G2.5
Note Other sizes available upon request.
11
Flexolex HD 2, 3, 4 & 5 Core
Cords/Cables, Unscreened
®
Construction 0.6/1kV EPR insulated and CPE sheathed heavy duty flexible cords to AS/NZS 3191 and AS/NZS 60245.3,
with bunched tinned copper conductors. Class 5 to AS/NZS 1125 and IEC 60228. Maximum 90°C continuous.
Cords
Nominal
conductor area
mm 2
3 Core (2+E )
0.75
1.0
1.5
2.5
4.0
4 Core (3+E )
1.5
2.5
4.0
5 Core (4+E )
1.5
2.5
4.0
Maximum
wire size
mm
Thickness
of insulation
mm
Thickness
of sheath
mm
Nominal overall diameter
mm
Approximate
mass
kg/100m
Product code
0.21
0.21
0.26
0.26
0.31
0.8
0.8
0.8
0.9
1.0
1.4
1.4
1.6
1.8
1.9
8.8
9.1
10.1
12.0
13.9
11
12
15
22
31
RDER52AA003
RDER53AA003
RDER54AA003
RDER55AA003
RDER56AA003
0.26
0.26
0.31
0.8
0.9
1.0
1.7
1.9
2.0
11.2
13.2
15.3
19
27
39
RDER54AA004
RDER55AA004
RDER56AA004
0.26
0.26
0.31
0.8
0.9
1.0
1.8
2.0
2.2
12.3
14.5
17.0
23
33
48
RDER54AA005
RDER55AA005
RDER56AA005
Maximum
wire size
mm
Thickness
of insulation
mm
Thickness
of sheath
mm
Nominal overall diameter
mm
Approximate
mass
kg/100m
Product code
Cables
Nominal
conductor area
mm 2
4 Core (3+E )
6
10
16
25
35
50
70
95
120
5 Core (4+E )
6
10
16
25
35
50
0.31
0.41
0.41
0.41
0.41
0.41
0.68
0.68
0.68
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
1.8
2.2
3.4
3.6
4.0
4.3
4.8
5.2
5.7
6.1
17.9
24.4
27.4
32.9
37.0
42.7
48.4
54.2
60.1
55
97
135
204
265
352
478
593
745
RDHR57AA004
RDHR58AA004
RDHR59AA004
RDHR60AA004
RDHR61AA004
RDHR62AA004
RDHR63AA004
RDHR64AA004
RDHR65AA004
0.31
0.41
0.41
0.41
0.41
0.41
1.0
1.2
1.2
1.4
1.4
1.6
2.4
3.6
3.8
4.3
4.6
5.1
19.9
26.8
30.2
36.4
40.6
47.2
68
118
164
251
322
431
RDHR57AA005
RDHR58AA005
RDHR59AA005
RDHR60AA005
RDHR61AA005
RDHR62AA005
INDUSTRIAL
12
Flexolex HD-S 4 & 5 Core
Cords/Cables, Screened
®
Construction 0.6/1kV EPR insulated, EPR bedded, collectively screened and CPE sheathed heavy duty flexible cords
to AS/NZS 3191 and AS/NZS 60245.3 where applicable, with bunched tinned copper conductors class 5 to AS/NZS 1125
and IEC 60228 and tinned copper braid screen. Maximum 90°C continuous.
Cords
Nominal
Maximum
Thickness
Thickness
Thickness
conductor area wire size
of insulation
of bedding
of sheath
mm 2
mm
mm
mm
mm
4 Core (3+E )
1.5
0.26
0.8
1.0
1.8
2.5
0.26
0.9
1.0
1.9
4.0
0.31
1.0
1.0
2.2
5 Core (4+E )
1.5
0.26
0.8
1.0
1.9
2.5
0.26
0.9
1.0
2.1
4.0
0.31
1.0
1.0
2.3
Product code
Nominal diameter
under screen
overall Approximate
mass
mm
mm
kg/100m
9.7
11.3
13.2
14.7
16.5
19.0
30
40
54
RDLR54AA004
RDLR55AA004
RDLR56AA004
10.6
12.4
14.5
15.8
18.0
20.5
35
48
64
RDLR54AA005
RDLR55AA005
RDLR56AA005
Cables
Nominal
Maximum
Thickness
Thickness
Thickness
conductor area wire size
of insulation
of bedding
of sheath
2
mm mm
mm
mm
mm
4 Core (3+E )
6
0.31
1.0
1.0
2.4
10
0.41
1.2
1.0
3.5
16
0.41
1.2
1.0
3.8
25
0.41
1.4
1.0
4.2
35
0.41
1.4
1.0
4.5
50
0.41
1.6
1.2
4.9
5 Core (4+E )
6
0.31
1.0
1.0
2.6
10
0.41
1.2
1.0
3.7
16
0.41
1.2
1.0
4.0
25
0.41
1.4
1.0
4.4
35
0.41
1.4
1.2
4.8
50
0.41
1.6
1.2
5.3
Product code
Nominal diameter
under screen
overall Approximate
mass
mm
mm
kg/100m
15.3
19.2
21.8
26.4
29.6
34.6
21.8
28.4
31.6
36.7
40.5
46.3
76
126
168
240
302
395
RDXR57AA004
RDXR58AA004
RDXR59AA004
RDXR60AA004
RDXR61AA004
RDXR62AA004
16.9
21.2
24.2
29.3
33.2
38.4
23.9
30.8
34.4
40.1
44.8
51.0
92
150
201
290
370
480
RDXR57AA005
RDXR58AA005
RDXR59AA005
RDXR60AA005
RDXR61AA005
RDXR62AA005
Flexolex® Cords
Flexolex® Cables
Standard core colours
Standard core colours
2 Core: Brown, Blue.
3 Core+3 Earths: Red, White, Blue and 3Green/Yellow.
3 Core: Brown, Blue, Green/Yellow.
4 Core: Red, White, Blue, Green/Yellow.
4 Core: Brown, Black, Blue, Green/Yellow.
5 Core: Red, White, Blue, Black, Green/Yellow.
5 Core: Brown, Black, White, Blue, Green/Yellow.
(Other colours available upon request, subject to minimum
ordering quantities.)
13
Flexolex SP Single Core
Power & Welding Cables
®
Construction 0.6/1kV CPE composite insulated and protected flexible cable to AS/NZS 1995 and AS/NZS 5000.1
where applicable, with taped multiple stranded plain copper conductors. Maximum 90°C continuous.
Application Designed suitable not only as a welding flexible but also for LV mains connected equipment
(e.g. switchgear), internal wiring or open jumper leads in restricted access areas requiring flexible connections.
Nominal
Maximum
conductor wire size
area
mm 2
mm
10
0.21
16
0.21
25
0.21
35
0.21
50
0.21
70
0.21
95
0.21
120
0.51
150
0.51
185
0.51
240
0.51
Nominal
conductor
diameter
mm
4.5
5.7
6.5
7.8
9.6
11.7
13.7
15.2
16.5
19.4
22.9
Thickness of
insul./protec.
covering
mm
2.0
2.0
2.0
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
Nominal overall
diameter
mm
8.9
10.1
10.9
12.2
14.4
16.9
19.4
21.3
23.1
26.4
30.3
Other sizes are available upon request, subject to minimum ordering quantities.
Standard colour
Black (other colours are available upon request, subject to minimum ordering quantities).
Additional data
For further data and recommendations see pages 15 and 16.
INDUSTRIAL
14
Approx.
mass
kg/100m
6.5
23
32
42
60
83
109
136
168
211
266
Product code
RDWX01AA001
RDWX02AA001
RDWX03AA001
RDWX04AA001
RDWX05AA001
RDWX06AA001
RDWX07AA001
RDWX08AA001
RDWX09AA001
RDWX10AA001
RDWX11AA001
Technical Data
Flexible Conductors
Current carrying capacity
Versolex® single core cables
Conductor
Unenclosed
area
Spaced
Spaced
Spaced
Touching
from surface
Three phase voltage drop
Trefoil
Laid flat
mm2
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
mV/A.m
4.22
2.68
1.73
1.23
0.868
0.621
0.480
0.386
0.322
0.277
0.229
0.203
0.179
0.165
0.155
mV/A.m
4.22
2.68
1.73
1.24
0.873
0.628
0.489
0.397
0.335
0.291
0.246
0.222
0.200
0.188
0.178
A
A
A
92 120 160 200 250 315 375
445
510 590 710 810 980 1140 1340 80 105 140 175 225 285 340
405 470
540 650 750 910 1060 1260 69
92
120
150
190
240
290
345
400
460
550
640
760
880
1030
Current carrying capacity
Versolex® in Fixed installation
Current carrying capacity
Flexible cords
Nominal
conductor area
mm 2
Current carrying capacity
A
Voltage drop 1 phase
mV/A.m
Voltage drop
3 phase
mV/A.m
0.75
1.0
1.5
2.5
4.0
7.5
10
15
20
25
63.3
47.5
32.3
19.4
12.0
54.8
41.1
28.0
16.8
10.4
Current carrying capacity
Flexible installation
Nominal
conductor area
Single phase Protected
Exposed
from sun
to sun
Three phase
Protected
from sun
Exposed
to sun
mm 2
A
A
A
A
6
10
16
25
35
50
70
95
120
54
74
99
135
165
195
250
290
340
43
58
77
105
125
145
185
210
245
46
63
85
115
140
165
215
250
290
37
50
66
88
105
125
155
180
210
Technical Data continues page 16.
A
65
86
115 140 180 225 270 325
375
425
510
590
710
820
960
Conductor Unenclosed area
Spaced
2
mm A
Single Phase (2 Core)
1
19
1.5
24
2.5
33
4
43
6
55
Three Phase (3 and 4 Core)
1
17
1.5
20
2.5
27
4
37
6
46
10
65
16
86
25
115
35
140
50
180
70
230
95
275
120
320
Unenclosed Touching
A
Voltage drop
mV/a.m
18
22
30
41
51
49.8
34.0
20.3
12.6
8.42
15
19
25
34
43
61
81
105
130
170
215
255
295
43.1
29.4
17.6
10.9
7.29
4.38
2.68
1.62
1.19
0.902
0.608
0.485
0.387
Welding Cables current ratings: Versolex® & Flexolex®
Current ratings for 5 minute period duty cycle
Nominal
cond. area
mm 2
Maximum duty cycle (AS 1966)
Continuous
Heavy
100%
60%
Light industrial
30%
Limited input
25%
10
16
25
35
50
70
95
120
150
185
240
90
125
165
205
260
325
390
455
535
600
715
114
169
239
309
407
523
644
762
904
1027
1236
121
181
257
334
440
567
700
829
985
1120
1348
96
137
188
238
308
391
476
559
661
747
895
15
Technical Data
Flexible Conductors
Conductor resistances
Recommendations
For the range of conductors covered in this catalogue.
The minimum bending radius or maximum pulling tension (and the
Nominal
Max. DC resistance at 20°C (AS 1125)
conductor
area Plain
Tinned
mm 2
Ω/km
Ω/km
Flexible Cords and Cables other than Type SP
0.50
39.0
40.1
0.75
26.0
26.7
1.0
19.5
20.0
1.5
13.3
13.7
2.5
7.98
8.21
4
4.95
5.09
6
3.30
3.39
10
1.91
2.02
16
1.21
1.24
25
0.780
0.795
35
0.554
0.565
50
0.386
0.393
70
0.272
0.277
95
0.206
0.210
120
0.161
0.164
150
0.129
0.132
185
0.106
0.108
240
0.0801
0.0817
300
0.0641
400
0.0486
500
0.0384
630
0.0287
like) a cable can withstand without detriment are subject to site
Conversion mm to AWG
2
mm 0.05
0.08
0.14
0.25
0.34
0.38
0.5
0.75
1
1.5
2.5
4
6
10
2
variations such as speed of bending or rate of application of tension.
To guard against damage and to ensure reasonable cable life, the
following are the Olex recommendations:
Minimum bending radii
Expressed in multiples of the cable overall diameter, D, following are
minimum recommended:
(a) Fixed (not subject to flexing) . . . . . . . . . . . . . . . . . . . . . . . 4 D
(b) Free flexing (not under tension) . . . . . . . . . . . . . . . . . . . . . 6 D
(c) Repetitive reeling (on/off drum) (1). . . . . . . . . . . . . . . . . . . 10 D
(d) Festoon (hangers) at cable saddles. . . . . . . . . . . . . . . . . . . 5 D
Maximum working tension
When a flexible cable is repetitively reeled, or pulled by a mobile
machine (powered by the cable), the maximum working tension on
cable at any time of an operating cycle, determined as a function
AWG
mm 30
16
28
25
26
35
24
50
22
70
21
95
20
120
18
150
17
185
16
240
14
300
12
400
10
500
8
2
AWG
6
4
2
1/0
2/0
3/0
4/0
300MCM
350MCM
500MCM
600MCM
800MCM
1000MCM
of the total main conductor cross-sectional area in the cable, should
not exceed the following recommended safe values:
(a) Multicore control cables. . . . . . . . . . . . . . . . . . . . . 15 N/mm 2
(b) Power cables (2) . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 N/mm 2
Notes
1 Where reeling of cables involves forced guiding (directional
changes, e.g. with cable axis changing from right angle to
parallel to the drum axis, or in-between, or where the cable is
subjected to an ‘S’ bend), the straight section of cable between
two adjacent bending points at sheaves or rollers shall be not
less than 20D.
2 Any control core components or reduced size conductors
(e.g. earth, pilot) located in the interstices of the laid-up
core assembly or any screens are not to be included in the
calculations.
INDUSTRIAL
16
Contents
NEW Rheyflex Y PVC Flexible Control Cable
18
NEW Rheyflex YCY PVC–EMC Flexible
Control Cable
19
PVC Flexible Drag Chain Cable
20
Robotics Cable
21
NEW H07VVH6-F PVC Flat Cable
22
NEW VCVH6-F Screened PVC Flat Cable
23
NEW Rheyflat®-N / NGFLGOEU-J
Rubber Flat Festoon Cable
24
NEW Rheyflat -N / (N)GFLCGOEU-J
Screened Rubber Flat Festoon Cable
25
NEW Boitalyon®R PVC
Pendant Overhead Crane Cable
26
NEW Buflex® X’Prem Reeling Cable
27
NEW Rheyhalon NSHXAFOE EN
28
Silicone Single Core Cable Halogen Free
29
®
Silicone Multicore Cable Flexible Halogen Free 30
Stranding and Current Ratings
Bus Technology Cables
Flexible Control
and Specialist
Applications
31
32–33
Current Carrying Capacity for H07VVH6-F,
HCVH6-F, Rheyflat®-N, Boitalyon®R
34
Bending Radius
34
Needing to push, pull, pick, place, lift, reel,
submerse, weld, pack, transport, measure,
inform or control more than ever?
Now, as a Nexans company, Olex has access to the world’s largest
cable range, enabling us to provide more cables and more solutions
to meet your ever increasing industrial cable demands.
Our new range of products includes cables for festoon systems,
cranes, reeling, locomotives and rolling stock, which complement
our existing range of control, high temperature, drag chain and
BUS cables. With Olex and Nexans you will stay in control.
17
Rheyflex Y
PVC Flexible Control Cable
Construction 300/500V cables, flexible PVC insulated and PVC sheathed to DIN VDE 0281 part 1 and HD 21.1, PVC
self extinguishing and flame retardant to test method B IEC 60332-1, copper conductors to DIN VDE 0295 class 5
and IEC 60228 class 5, flexing –5°C to 80°C, fixed –40°C to 80°C. Minimum bending radius 7.5cable o.d.
Application These cables are designed for flexible use involving medium mechanical stresses with free movement
in dry, moist and wet rooms, as measuring and control cables in tool machines, conveyor belts and production lines
in machinery production, in air conditioning and steel production. Not suitable for open air applications.
No. cores &
Nominal
Approx.
cross-sec.
diameter
mass
2
mm mm
kg/km
2C
0.5
4.8
40
0.75
5.2
46
1
5.5
60
1.5
6.3
70
2.5
7.6
112
4
9.2
195
2C+E
0.5
5.1
46
0.75
5.5
54
1
6
72
1.5
6.7
90
2.5
8.3
148
4
9.9
230
6
11.7
355
10
15
540
3C
0.5
5.1
46
0.75
5.5
54
1
6
72
1.5
6.7
90
2.5
8.3
148
3C+E
0.5
5.7
56
0.75
6.2
66
1
6.6
86
1.5
7.3
109
2.5
9.1
178
4
11
295
6
13
424
10
16.8
701
4C
0.5
5.7
56
0.75
6.2
66
1
6.6
86
1.5
7.3
109
2.5
9.1
178
4C+E
0.5
6.2
65
0.75
6.8
80
1
7.2
104
1.5
8.2
131
2.5
10.2
221
4
12.1
361
6
14.5
525
10
18.7
858
5C
0.5
6.2
65
0.75
6.8
80
1
7.2
104
1.5
8.2
131
2.5
10.2
221
18
Product
code
CC2X0.5
CC2X0.75
CC2X1
CC2X1.5
CC2X2.5
CC2X4
CC3G0.5
CC3G0.75
CC3G1
CC3G1.5
CC3G2.5
CC3G4
CC3G6
CC3G10
CC3X0.5
CC3X0.75
CC3X1
CC3X1.5
CC3X2.5
CC4G0.5
CC4G0.75
CC4G1
CC4G1.5
CC4G2.5
CC4G4
CC4G6
CC4G10
CC4X0.5
CC4X0.75
CC4X1
CC4X1.5
CC4X2.5
CC5G0.5
CC5G0.75
CC5G1
CC5G1.5
CC5G2.5
CC5G4
CC5G6
CC5G10
CC5X0.5
CC5X0.75
CC5X1
CC5X1.5
CC5X2.5
No. cores &
cross-sec.
mm 2
6C+E
0.5
0.75
1
1.5
2.5
4
6
11C+E
0.5
0.75
1
1.5
2.5
17C+E
0.5
0.75
1
1.5
2.5
24C+E
0.5
0.75
1
1.5
2.5
41C+E
0.5
0.75
1
1.5
2.5
64C+E
0.5
0.75
1
1.5
Nominal
diameter
mm
Approx.
mass
kg/km
Product
code
7.4
8.1
8.6
9.8
12.1
13.3
16
80
110
141
184
306
458
625
CC7G0.5
CC7G0.75
CC7G1
CC7G1.5
CC7G2.5
CC7G4
CC7G6
9.1
9.9
10.7
12.1
15.2
135
179
230
309
498
CC12G0.5
CC12G0.75
CC12G1
CC12G1.5
CC12G2.5
10.7
11.9
12.7
14.5
18.1
196
257
343
440
764
CC18G0.5
CC18G0.75
CC18G1
CC18G1.5
CC18G2.5
13
14.5
15.6
17.8
22.2
270
365
485
620
1044
CC25G0.5
CC25G0.75
CC25G1
CC25G1.5
CC25G2.5
15.8
17.6
18.9
21.4
27.2
449
612
810
1007
1790
CC42G0.5
CC42G0.75
CC42G1
CC42G1.5
CC42G2.5
19.4
21.5
22.8
26
682
895
1180
1602
CC65G0.5
CC65G0.75
CC65G1
CC65G1.5
G = with green-yellow earth core.
X = without green-yellow earth core (OZ).
Note Black cores with continuous white numbering according
to DIN VDE 0293. Other configurations available upon request.
Rheyflex YCY
PVC – EMC Flexible Control Cable
Construction 300/500V cables to 1.5mm & 450/750V at 2.5mm & above, flexible PVC insulated, tinned copper braided
with transparent PVC sheath, copper conductors to DIN VDE 0295 class 5, flexing –5°C to 80°C, fixed –40°C to 80°C.
Cores available in either black with white numbering or coloured cores. Minimum bending radius 10cable o.d.
Application For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for
electronics. The high level of screening ensures a high degree of interference protection. The screening density assures
disturbance free transmission of all signals and impulses.
No. cores &
Nominal
Approx.
cross-sec.
diameter
mass
2
mm mm
kg/km
2C
0.5
6.9
67
0.75
7.6
87
1
7.9
97
1.5
8.4
130
2.5
10
180
2C+E
0.5
7.2
83
0.75
7.8
98
1
8.2
103
1.5
9
152
2.5
10.7
216
4
12.3
340
6
14.2
450
3C+E
0.5
7.8
94
0.75
8.3
113
1
8.9
146
1.5
9.6
168
2.5
11.4
267
4
13.4
410
6
15.6
559
4C+E
0.5
8.3
108
0.75
9.1
130
1
9.5
169
1.5
10.5
202
2.5
12.5
347
4
14.8
502
6
17
702
6C+E
0.5
9.5
136
0.75
10.4
184
1
11
219
1.5
12.1
304
2.5
15
407
4
16.2
638
6
18.7
907
11C+E
0.5
11.3
195
0.75
12.5
292
1
13.1
350
1.5
14.9
434
2.5
18
722
17C+E
0.5
13.1
277
0.75
14.3
358
1
15.4
514
24C+E
0.5
15.7
407
0.75
17.4
508
1
18.3
689
Product
code
CY2X0.5
CY2X0.75
CY2X1
CY2X1.5
CY2X2.5
CY3G0.5
CY3G0.75
CY3G1
CY3G1.5
CY3G2.5
CY3G4
CY3G6
CY4G0.5
CY4G0.75
CY4G1
CY4G1.5
CY4G2.5
CY4G4
CY4G6
CY5G0.5
CY5G0.75
CY5G1
CY5G1.5
CY5G2.5
CY5G4
CY5G6
CY7G0.5
CY7G0.75
CY7G1
CY7G1.5
CY7G2.5
CY7G4
CY7G6
CY12G0.5
CY12G0.75
CY12G1
CY12G1.5
CY12G2.5
CY18G0.5
CY18G0.75
CY18G1
CY25G0.5
CY25G0.75
CY25G1
No. cores &
cross-sec.
mm 2
40C+E
0.5
0.75
1
60C+E
0.5
0.75
1
Coloured Cores
2C + E
1
1.5
2.5
4
6
10
3C+E
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
4C+E
1
1.5
2.5
4
6
10
16
25
35
50
Nominal
diameter
mm
Approx.
mass
kg/km
Product
code
19
21.2
22.1
671
971
1092
CY41G0.5
CY41G0.75
CY41G1
22.9
25
26.2
850
1290
1370
CY61G0.5
CY61G0.75
CY61G1
8.2
9
10.7
12.3
14.2
17.8
103
152
216
340
450
750
CY3G1JB
CY3G1.5JB
CY3G2.5JB
CY3G4JB
CY3G6JB
CY3G10JB
8.9
9.6
11.4
13.4
15.6
19.7
22.6
28.9
32.2
38.2
46.8
51
56
63.5
68
146
168
267
410
559
1020
1380
1890
2390
3315
4600
6060
7315
9340
11120
CY4G1JB
CY4G1.5JB
CY4G2.5JB
CY4G4JB
CY4G6JB
CY4G10JB
CY4G16JB
CY4G25JB
CY4G35JB
CY4G50JB
CY4G70JB
CY4G95JB
CY4G120JB
CY4G150JB
CY4G185JB
9.5
10.5
12.5
14.8
17
21.6
25.2
31.8
36.4
43
169
202
347
502
702
1115
1553
2270
2885
4150
CY5G1JB
CY5G1.5JB
CY5G2.5JB
CY5G4JB
CY5G6JB
CY5G10JB
CY5G16JB
CY5G25JB
CY5G35JB
CY5G50JB
G = with green-yellow earth core.
X = without green-yellow earth core (OZ).
JB = coloured cores.
Note Black cores with continuous white numbering according
to DIN VDE 0293.
19
PVC Flexible
Drag Chain Cable
Construction 300/500V cables, flexible PVC insulated and PVC sheathed to DIN VDE 0281 part 1 and HD 21.1, PVC
self extinguishing and flame retardant to test method B IEC 60332-1, copper conductors to DIN VDE 0295 class 6
and IEC 60228 class 6, flexing –5°C to 80°C, fixed –40°C to 80°C. Minimum bending radius 7.5cable o.d.
Application Drag chain cables are ideal for use in the machine tool industry, in robotics and machine production
and anywhere high flexibility is essential. These cables have shown excellent performance in cable chain systems.
Suitable for flexible use for medium mechanical stresses with free movements.
No. cores &
cross-sec.
mm 2
2C
0.5
0.75
1
1.5
2.5
2C+E
0.5
0.75
1
1.5
2.5
4
3+E
0.5
0.75
1
1.5
2.5
4
6
10
4C+E
0.5
0.75
1
1.5
2.5
4
6
10
6C+E
0.5
0.75
1
1.5
2.5
Approx.
mass
kg/km
Product
code
5
5.4
5.7
6.4
7.7
46
58
65
91
130
HF2X0.5
HF2X0.75
HF2X1
HF2X1.5
HF2X2.5
5.3
5.7
6
6.8
8.4
10.4
57
73
84
117
160
221
HF3G0.5
HF3G0.75
HF3G1
HF3G1.5
HF3G2.5
HF3G4
5.7
6.4
6.8
7.4
9.1
11.4
13.3
17.7
70
77
113
147
200
260
392
642
HF4G0.5
HF4G0.75
HF4G1
HF4G1.5
HF4G2.5
HF4G4
HF4G6
HF4G10
6.4
7
7.4
8.3
10.2
12.7
14.5
19.7
93
119
137
181
269
318
481
780
HF5G0.5
HF5G0.75
HF5G1
HF5G1.5
HF5G2.5
HF5G4
HF5G6
HF5G10
7.5
8.3
8.8
9.9
12.2
127
165
192
273
357
HF7G0.5
HF7G0.75
HF7G1
HF7G1.5
HF7G2.5
Nominal
diameter
mm
G = with green-yellow earth core.
X = without green-yellow earth core (OZ).
Note Black cores with continuous white numbering
according to DIN VDE 0293.
No. cores &
cross-sec.
mm 2
11C+E
0.5
0.75
1
1.5
2.5
17C+E
0.5
0.75
1
1.5
2.5
24C+E
0.5
0.75
1
1.5
2.5
41C+E
0.5
0.75
1
1.5
2.5
64C+E
0.75
1
1.5
Nominal
diameter
mm
Approx.
mass
kg/km
Product
code
9.2
10.2
10.8
12.1
15.2
177
247
295
391
572
HF12G0.5
HF12G0.75
HF12G1
HF12G1.5
HF12G2.5
11.1
12.1
13
14.5
18.1
284
356
420
590
800
HF18G0.5
HF18G0.75
HF18G1
HF18G1.5
HF18G2.5
13.4
14.9
15.8
17.8
22.5
363
498
600
801
1100
HF25G0.5
HF25G0.75
HF25G1
HF25G1.5
HF25G2.5
16.1
18.1
19.3
21.5
27.4
575
600
948
1290
1800
HF42G0.5
HF42G0.75
HF42G1
HF42G1.5
HF42G2.5
24.7
23.7
27.6
841
1400
1994
HF65G0.75
HF65G1
HF65G1.5
G = with green-yellow earth core.
X = without green-yellow earth core (OZ).
Note Black cores with continuous white numbering according
to DIN VDE 0293.
Flexible drag chain cables also available with PUR sheath to class 6
stranding. Variations including braided construction also available in
both PVC and PUR materials.
Please consult your Olex sales office or the Olex website
for further information.
20
Robotics Cable
Construction 300/500V cables, flexible PVC insulated and polyurethane sheathed, PUR sheath flame retardant to test
method B IEC 60332-1, copper conductors to DIN VDE 0295 class 6 and IEC 60228 class 6, flexing –30°C to 80°C, fixed
–40°C to 80°C. Minimum bending radius 7.5cable o.d.
Application These special robotic power and control cables are specially designed for torsion and bending stresses
found in robotic applications.
No. cores
cross-sec.
mm 2
70.25 250.25 20.34 30.34 12 G 0.5 18 G 0.5 25 G 0.5 4 G 0.75 12 G 0.75 14 G 0.75 21 3 G 1 4 G 1 7 G 1 12 G 1 18 G 1 25 G 1 34 G 1 41 G 1 12 G 1.5 18 G 1.5 25 G 1.5 3 G 2.5 4 G 2.5 3 G 4 3 G 10 3 G 16 3 G 25 3 G 35
Nominal
diameter
mm
5.8
10.4
4.0
4.0
10.4
12.7
14.2
6.0
11.5
12.8
6.0
6.0
6.3
8.5
12.5
15.4
17.4
21.3
23.2
15.5
19.3
21.8
8.4
9.1
10.3
15.6
18.2
22.9
26.5
Approx.
mass
kg/km
48
143
28
34
90
121
256
63
171
200
48
60
78
131
216
306
432
569
694
356
445
636
136
170
227
518
722
1180
1600
Product
code
RCC7X0.25
RCC25X0.25
RCC2X0.34
RCC3X0.34
RCC12G0.5
RCC18G0.5
RCC25G0.5
RCC4G0.75
RCC12G0.75
RCC14G0.75
RCC2X1
RCC3G1
RCC4G1
RCC7G1
RCC12G1
RCC18G1
RCC25G1
RCC34G1
RCC41G1
RCC12G1.5
RCC18G1.5
RCC25G1.5
RCC3G2.5
RCC4G2.5
RCC3G4
RCC3G10
RCC3G16
RCC3G25
RCC3G35
No. cores
cross-sec.
mm 2
120.14 180.14 250.14 120.25 180.25 250.25 120.34 180.34 250.34 12 G 0.5 18 G 0.5 25 G 0.5 12 G 0.75 18 G 0.75 25 G 0.75 12 G 1 18 G 1 25 G 1 12 G 1.5 18 G 1.5 25 G 1.5
Nominal
diameter
mm
7.8
9.7
10.9
8.3
10.1
11.1
8.8
10.8
12.1
11.2
13.6
14.8
11.8
15.0
16.6
13.0
16.1
18.0
16.2
20.3
22.5
Approx.
mass
kg/km
95
120
158
126
164
215
160
210
305
175
231
347
220
305
415
265
390
540
345
485
710
Product
code
RCY12X0.14
RCY18X0.14
RCY25X0.14
RCY12X0.25
RCY18X0.25
RCY25X0.25
RCY12X0.34
RCY18X0.34
RCY25X0.34
RCY12G0.5
RCY18G0.5
RCY25G0.75
RCY12G0.75
RCY18G0.75
RCY25G0.75
RCY12G1
RCY18G1
RCY25G1
RCY12G1.5
RCY18G1.5
RCY25G1.5
G = with green-yellow earth core.
X = without green-yellow earth core (OZ).
21
H07VVH6-F
PVC Flat Cable
Construction 450/750V cables, PVC insulated and PVC sheathed. Insulation includes threads in each group of cores
to assist when stripping the outer sheath. Plain copper conductors to IEC 60228 Class 5.
Application These power and control cables can be used on festoon systems on handling equipment, e.g. overhead
cranes. Specially designed for indoor and outdoor applications.
No. cores
cross-sec.
mm 2
Power
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50
4 G 70
4 G 95
5 G 4
5 G 6
5 G 10
5 G 16
7 G 4
7 G 6
Control
4 G 1.5
4 G 2.5
5 G 1.5
5 G 2.5
7 G 1.5
7 G 2.5
8 G 1.5
8 G 2.5
10 G 1.5
12 G 1.5
12 G 2.5
12 G 4
14 G 1.5
16 G 1.5
18 G 1.5
Approx. outer
dimensions
mm
Approx.
weight
kg/km
Product
code
216.5
237
299
3711
4613.5
5114.8
5616.5
6318
7320.5
256.5
287
359
4311
376.5
417
300
390
620
990
1550
2030
2650
3650
4550
380
480
780
1200
550
700
FC4G4
FC4G6
FC4G10
FC4G16
FC4G25
FC4G35
FC4G50
FC4G70
FC4G95
FC5G4
FC5G6
FC5G10
FC5G16
FC7G4
FC7G6
155
18.56
185
226
265
326
295
356
355
40.55
50.56
576.5
485
545
585
150
210
180
260
260
380
300
405
360
420
620
880
490
560
620
FC4G1.5
FC4G2.5
FC5G1.5
FC5G2.5
FC7G1.5
FC7G2.5
FC8G1.5
FC8G2.5
FC10G1.5
FC12G1.5
FC12G2.5
FC12G4
FC14G1.5
FC16G1.5
FC18G1.5
Mechanical Properties
Tensile stress of the conductor
static
15N/mm 2
dynamic
30N/mm 2
Bending radii
Refer to page 34
Tests
Bending test
Travelling festoon speed
up to 120m/min
Electrical and Thermal Properties
Nominal voltage
U o /U
450/750V
Um
750V
Maximum operating voltage
in AC systems
Test Voltage:
2.5k/V–50Hz in AC
Current Rating
Refer to page 34
Max. temperature at the conductor:
in service
+70°C
in short-circuit
+150°C
Max. surface temperature fixed installations –35°C up to +60°C
mobile operation –25°C up to +60°C
Cores Identifications
In accordance with HD 308 S2
4 cores: black, grey, green/yellow, brown
5 cores: black, grey, green/yellow, brown, blue
>5 cores: black with white printed numbers+green/yellow
INDUSTRIAL
22
VCVH6-F
Screened PVC Flat Cable
Construction 300/500V (control) and 0.6/1 (1.2)k/V (power) cables, PVC insulated and outer sheath, screened with
plain copper braid (control) and plain copper spinning on phase cores - earth core is unscreened (power), plain copper
conductors to IEC 60228 Class 5.
Application These power and control cables can be used for hoisting control systems in festoons on overhead cranes.
Copper screens are efficient against electro magnetic disturbances caused by power and control cables.
No. cores
cross-sec.
mm 2
Power
4 G 4
4 G 6
4 G 10
4 G 16
4 G 25
4 G 35
Control
41.5
81.5
121.5
Approx. outer
dimensions
mm
Approx.
weight
kg/km
Product
code
237
299
3711
4614
5014.5
5516
360
580
900
1280
1800
2300
FCY4G4
FCY4G6
FCY4G10
FCY4G16
FCY4G25
FCY4G35
185.5
345.5
505.5
220
430
650
FCY41.5
FCY81.5
FCY121.5
Mechanical Properties
Tensile stress of the conductor
static
15N/mm2
dynamic
30N/mm2
Bending radii
Refer to page 34
Tests
Bending test
Travelling festoon speed
up to 120m/min
Electrical and Thermal Properties
Test Voltage:
control
2.0k/V–50Hz in AC
power
2.5k/V–50Hz in AC
Current Rating
Refer to page 34
Max. temperature at the conductor:
in service
+70°C
in short-circuit
+150°C
Max. surface temperature fixed installations –35°C up to +60°C
mobile operation –25°C up to +60°C
Cores Identifications
Power: black, grey, brown, green/yellow
Control: black with white printed numbers
23
Rheyflat-N / NGFLGOEU-J
Rubber Flat Festoon Cable
®
Construction 300/500V cables, EPR rubber compound insulated, PCP rubber compound outer sheath, plain copper
conductors, ≤ 25mm2 extra flexible stranded class 6, ≥ 35mm2 flexible stranded class 5, to IEC 60228/DIN VDE 0295.
Application These cables are used for festoon and handling systems, machine tools, lifts and e-chain cable carrier
systems. For applications with high mechanical stress and frequent bending in one plane only
No. cores
cross-sec.
mm 2
Power
4 G 4
5 G 4
7 G 4
4 G 6
5 G 6
7 G 6
4 G 10
5 G 10
4 G 16
5 G 16
4 G 25
5 G 25
7 G 25
4 G 35
7 G 35
4 G 50
4 G 70
4 G 95
4 G 120
Control
4 G 1.5
5 G 1.5
7 G 1.5
8 G 1.5
10 G 1.5
12 G 1.5
24 G 1.5
4 G 2.5
5 G 2.5
7 G 2.5
8 G 2.5
12 G 2.5
24 G 2.5
Approx. outer
dimensions
mm
Approx.
weight
kg/km
Product
code
926
932
942
9.529
9.535
9.542
1133
1144
1338
1350
1549.5
1660
1680
1755
1788
1963
2271
2580
2786
410
560
700
600
650
850
800
1000
1150
1450
1700
2200
3060
2200
3900
3000
4000
5300
6400
RFC44
RFC54
RFC74
RFC46
RFC56
RFC76
RFC410
RFC510
RFC416
RFC516
RFC425
RFC525
RFC725
RFC435
RFC735
RFC450
RFC470
RFC495
RFC4120
6.217.5
6.2215
6.229
6.231.5
6.540
6.547
12.555
7.521
7.527
7.535
7.539
856
1668
200
240
360
370
520
620
1300
280
400
520
550
800
1850
RFC41.5
RFC51.5
RFC71.5
RFC81.5
RFC101.5
RFC121.5
RFC241.5
RFC42.5
RFC52.5
RFC72.5
RFC82.5
RFC122.5
RFC242.5
INDUSTRIAL
24
Mechanical Properties
Tensile stress of the conductor
static
15N/mm 2
dynamic
30N/mm 2
Bending radii
Refer to page 34
Tests
Bending test
Travelling festoon speed
up to 180m/min
Electrical and Thermal Properties
Test Voltage: 2.0k/V–50Hz in AC
Current Rating
Refer to page 34
Max. temperature at the conductor:
in service
+90°C
under short-circuit conditions +250°C
Max. surface temperature
fixed installations
–50°C up to +80°C
mobile operation
–35°C up to +80°C
Cores Identification
DIN VDE 0293 part 308/HD 308 S2
4 cores: black, grey, green/yellow, brown
5 cores: black, grey, green/yellow, brown, blue
>5 cores: black with white printed numbers & green/yellow
Rheyflat-N / (N)GFLCGOEU-J
Screened Rubber Flat Festoon Cable
®
Construction 300/500V cables, EPR rubber compound insulated, PCP rubber compound outer sheath, tinned copper
braid screen with >80% coverage, flame retardant, plain copper conductors, ≤ 25mm2 extra flexible stranded class 6,
≥ 35mm2 flexible stranded class 5, to IEC 60228/DIN VDE 0295.
Application These cables are used for festoon and handling systems, machine tools, lifts and e-chain cable carrier
systems. For applications with high mechanical stress and frequent bending in one plane only. Copper screens are
efficient against electro magnetic disturbances caused by power cables.
No. cores
cross-sec.
mm 2
Power
4 G 4 C
4 G 6 C 4 G 10 C 4 G 16 C
4 G 25 C 4 G 35 C
4 G 50 C
Control
4 G 1.5 C
8 G 1.5 C
12 G 1.5 C
4 G 2.5 C
12 G 2.5 C
Bus
4(21) C
Approx. outer
dimensions
mm
Approx.
weight
kg/km
Product
code
2910.5
3110.5
3611.5
41.513.5
4715
5517
6620.5
505
605
840
1180
1605
2520
3000
RFCY44C
RFCY46C
RFCY410C
RFCY416C
RFCY425C
RFCY435C
RFCY450C
18.56.5
367.5
54.58.5
22.57.5
69.59.5
220
470
745
320
1180
RFCY41.5C
RFCY81.5C
RFCY121.5C
RFCY42.5C
RFCY122.5C
3712.5
640
RFCY421C
Mechanical Properties
Tensile stress of the conductor
static
15N/mm2
dynamic
30N/mm2
Bending radii
Refer to page 34
Tests
Bending test
Travelling festoon speed
up to 180m/min
Electrical and Thermal Properties
Test Voltage: 2.0k/V in AC
(according to DIN VDE 0250 part 809)
Current Rating
Refer to page 34
Max. temperature at the conductor:
in service
+90°C
under short-circuit conditions +250°C
Max. surface temperature
fixed installations
–50°C up to +80°C
mobile operation
–35°C up to +80°C
Cores Identification
DIN VDE 0293 part 308/HD 308 S2
4 cores: black, grey, green/yellow, brown
5 cores: black, grey, green/yellow, brown, blue
>5 cores: black with white printed numbers & green/yellow
25
Boitalyon R
PVC Pendant Overhead Crane Cable
®
Construction 300/500V cables, flexible XLPE insulated with twin figure 8 PVC outer sheathed, plain copper conductors
to IEC 60228 Class 5.
Application These cables are specially designed with lateral suspension strands and are used in remote control
overhead cranes from push button boxes. They can also be used for installations where the hanging length of the cable
does not exceed 50m.
No. cores
cross-sec.
mm 2
51.5
81.5
121.5
12 G 1.5
161.5
201.5
20 G 1.5
301.5
Approx. outer
dimensions
mm
209.5
2412.5
2412.5
2412.5
25.514.5
2715.5
2715.5
3019
Approx.
weight
kg/km
210
300
350
350
440
520
520
700
Product
code
RPC51.5
RPC81.5
RPC121.5
RPC12G1.5
RPC161.5
RPC201.5
RPC20G1.5
RPC301.5
Mechanical Properties
Max. tensile load of the two steel supports
1000N
Bending radii
10D (cable diameter)
Tests
Alternating/reversed bending test,
torsional resistance test
Electrical and Thermal Properties
Nominal voltage
Uo/U
300/500V
Um
500V
Maximum operating voltage
in AC systems
Test Voltage: 2.5k/V in AC
Current Rating
Refer to page 34
Max. temperature at the conductor:
in service
+90°C
in short-circuit
+250°C
Max. surface temperature mobile operation –25°C up to +60°C
INDUSTRIAL
26
Buflex X’Prem
Reeling Cable
®
Construction 0.6/1kV cables, XLPE insulated with double layer anti-twisting reinforced polyurethane outer sheath,
plain copper conductors to IEC 60228 Class 5. Includes central strength member.
Application Buflex X’Prem cables with polyurethane sheath are specially designed for reeling applications, with high
mechanical stresses and severe environmental conditions such as torsion, tension, torque and abrasion. Reeling speed
up to 150m/min.
No. cores cross-sec. weight mm 2 Power
4 G 2.5
4 G 4
4 G 6
4 G 10
4 G 16
325+3 G 6
335+3 G 6
350+3 G 10
370+3 G 16
395+3 G 16
3120+3 G 25
3150+3 G 25
3185+3 G 35
3240+3 G 50
3300+3 G 50
5 G 2.5
5 G 4
5 G 6
5 G 10
5 G 16
5 G 25
5 G 35
Control
71.5
121.5
181.5
241.5
361.5
72.5
122.5
182.5
242.5
362.5
422.5
262.5+(42.5)C
Outer diameter
Approx.
Min.
Max.
mm mm
kg/km
Max. tensile
load (N)
Product
Code
10
11.5
13
15.5
19.5
23.5
27
30
35
39
44
49
54.5
60.5
68.5
11
13
15
18
22
27
31
11.5
13
14.5
17
21.5
25.5
29.5
32.5
37.5
42
47
52.5
58.5
64.5
72.5
12.5
14.5
16.5
20
24
29.5
33.5
180
260
370
580
920
1240
1640
2240
3100
3890
5080
6160
7680
9870
12300
220
320
450
700
1100
1550
2050
250
400
600
1000
1600
1960
2650
3750
5250
7150
9000
11250
13800
18000
22500
310
500
750
1250
2000
3100
4350
BXP4G2.5
BXP4G4
BXP4G6
BXP4G10
BXP4G16
BXP325.3G6
BXP335.3G6
BXP350.3G10
BXP370.3G16
BXP395.3G16
BXP3120.3G25
BXP3150.3G25
BXP3185.3G35
BXP3240.3G50
BXP3300.3G50
BXP5G2.5
BXP5G4
BXP5G6
BXP5G10
BXP5G16
BXP5G25
BXP5G35
11.5
16
16
19
22
12.5
18.5
18.5
22.5
25
27
24.5
13
17.5
17.5
21.5
24
14
20.5
20.5
24.5
28
29.5
27
210
330
410
680
900
30
610
740
1050
1430
1500
1260
260
450
670
900
1350
430
750
1120
1500
2250
2620
1870
BXP71.5
BXP121.5
BXP181.5
BXP241.5
BXP361.5
BXP72.5
BXP122.5
BXP182.5
BXP242.5
BXP362.5
BXP422.5
BXP262.5PLUS
Mechanical Properties
Max. tensile load 25N/mm 2 of phases copper cross section
Bending radii
Fixed: 6d
Mobile: 8d
S-shape deflection: 20d
Tests
Bending test, torsional test, reeling test
Reeling speed
up to 150m/min (for higher speed contact us)
Electrical and Thermal Properties
Test Voltage: Power 3.5k/V in AC
Control 2.5k/V in AC
Current Rating
in accordance with IEC 60354-5-52-12
Max. temperature at the conductor:
in service
+90°C
under short-circuit conditions +250°C
Max. surface temperature fixed installation –40°C up to +80°C
Cores Identification
Control: white with printed numbers
Power 4 cores: black, brown, grey, green/yellow
(3 earth cores for sizes >25mm 2)
Power 5 cores: black, brown, grey, blue, green/yellow
27
Rheyhalon
4GKW EN
Construction 1.8/3 (3.6)k/V cables designed to EN 50264-3-1 table 3, special cross-linked EPR, rubber type EI 110
insulation and special cross-linked EPR rubber type EI 104 sheath according to EN 50264-1, flexible stranded tinned
copper conductor according to DIN VDE 0295/IEC 60228/HD 383 class 5, conductor wrapping optional.
Application These cables are used for rolling stock (locomotives, trains, trolleybusses, etc), switching stations and
control panel applications.
Cross section mm 2 2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
Approx. outer
diameter min.
mm 6.2
6.8
7.4
8.7
9.8
10.3
11.4
13.3
15.3
17.0
19.3
21.6
23.5
26.6
29.3
34.1
Approx. outer
diameter max.
mm
6.5
7.2
7.9
9.2
10.6
10.9
12.0
13.9
15.9
17.6
19.9
22.2
24.1
27.2
30.1
34.9
Electrical Properties
Nominal voltage
Uo/U (Umax)=1.8/3.0 (3.6)kV
Maximum operating voltage in
DC installations, one-sided earthed
Vo=2.7kV DC
Testing AC Voltage (5 minutes): U=6.5kV
Max. operating temperature at the conductor:
conductor at normal operation ≤ 90°C/100,000h
≤ 120°C/20,000h
overload
≤160°C/50h
conductor under short-circuit conditions (tinned) ≤ 200°C
Min. permissable ambient temperature
operating in cold ≥ –40°C
Min bending radii
fixed installation ≥ 5D
free moved
INDUSTRIAL
28
≥ 10D
D=cable Ø
Caloric load
approx.
kWh/m
0.22
0.25
0.3
0.35
0.45
0.40
0.46
0.60
0.75
0.85
1.10
1.35
1.50
1.90
2.20
3.50
Approx.
weight
kg/km
60
80
100
160
230
290
400
550
750
970
1250
1550
1900
2450
3050
4000
Product
Code
RSHXAFOE1X2.5BLK
RSHXAFOE1X4BLK
RSHXAFOE1X6BLK
RSHXAFOE1X10BLK
RSHXAFOE1X16BLK
RS4GKW-EN1X25BLK
RS4GKW-EN1X35BLK
RS4GKW-EN1X50BLK
RS4GKW-EN1X70BLK
RS4GKW-EN1X95BLK
RS4GKW-EN1X120BLK
RS4GKW-EN1X150BLK
RS4GKW-EN1X185BLK
RS4GKW-EN1X240BLK
RS4GKW-EN1X300BLK
RS4GKW-EN1X400BLK
Silicone Single Core Cable
Halogen Free
Construction 500V cables, fixed or flexible conductor silicone insulated with or without glass fibre braiding, halogen
free to IEC 60754-2, tinned copper conductors to DIN VDE 0295 class 5 and IEC 60228 class 5, fixed –60°C to 180°C.
Min. bending radius 15cable o.d.
Application Silicone cables are suitable wherever cables are subjected to extreme temperature changes. They are used
mainly in the steel producing and aviation industries as well as in ship building, cement, glass and ceramic factories.
These cables are halogen free and especially suitable for use in power stations.
Cross
Nominal
section
diameter
mm 2
mm
Type SiF – Tinned copper conductors, silicone core insulation
0.25
1.9
0.5
2.1
0.75
2.4
1
2.5
1.5
2.8
2.5
3.4
4
4.2
6
5.2
10
7.0
16
8.4
25
10.3
35
11.6
50
13.9
70
16.0
95
18.4
120
20.0
150
23.0
185
24.9
Type SiF/GL – As SiF plus glass fibre braiding
0.25
2.4
0.5
2.6
0.75
2.9
1
3.0
1.5
3.3
2.5
3.9
4
4.7
6
5.7
10
7.5
16
8.9
25
10.8
35
12.1
50
14.4
G = with green-yellow earth core.
X = without green-yellow earth core (OZ).
Approx.
mass
kg/km
Product
code
5.5
8.6
11.8
13.5
18.5
30.0
47.3
71.1
119.4
187.7
289.6
398.3
559.7
765.8
1031.5
1284.6
1563.4
1858.2
SIF232
SIF233
SIF234
SIF235
SIF236
SIF237
SIF238
SIF239
SIF246
SIF247
SIF248
SIF23953
SIF23954
SIF23955
SIF23956
SIF23957
SIF23958
SIF23959
7.7
12.4
16.2
18.2
23.4
35.2
53.5
77.4
129.2
198.4
303.0
413.2
577.8
SIF/GL47001
SIF/GL47002
SIF/GL47003
SIF/GL47004
SIF/GL47005
SIF/GL47006
SIF/GL47007
SIF/GL47008
SIF/GL47009
SIF/GL47010
SIF/GL47011
SIF/GL47012
SIF/GL47013
Silicone single and multicore resistances
to oil and acids




High molecular oils
Fats from vegetables and animals
Alcohols
Plasticisers




Diluted acids
Salt dissolution
Oxidation substances
Oxygen and UV
29
Silicone Multicore Cable
Flexible Halogen Free
Construction 300/500V cables, silicone insulated, silicone sheathed, halogen free to IEC 60754-2, tinned copper
conductors to DIN VDE 0295 class 5 and IEC 60228 class 5, fixed –60°C to 180°C (peak 220°C). Min. bending radius
7.5cable o.d.
Application Silicone cables are suitable wherever cables are subjected to extreme temperature changes. They
are used mainly in the steel producing and aviation industries as well as in ship building, cement, glass and ceramic
factories. These cables are halogen free and especially suitable for use in power stations.
No. cores &
cross-sec.
mm 2
2C
0.5
0.75
1
1.5
2.5
2C+E
0.5
0.75
1
1.5
2.5
4
6
3C+E
0.5
0.75
1
1.5
2.5
4
6
4C+E
0.5
0.75
1
1.5
2.5
4
6
6C+E
1
1.5
2.5
4
11C+E
1
1.5
2.5
G = with green-yellow earth core.
X = without green-yellow earth core (OZ).
INDUSTRIAL
30
Approx.
mass
kg/km
Product
code
5.5
6.4
6.6
7.6
9.2
42
53
59
81
134
SF2X0.5
SF2X0.75
SF2X1
SF2X1.5
SF2X2.5
5.8
6.8
7.4
8
9.7
11.4
14.2
44
63
77
98
152
224
338
SF3G0.5
SF3G0.75
SF3G1
SF3G1.5
SF3G2.5
SF3G4
SF3G6
6.2
7.8
8
8.8
10.6
13.1
16.2
58
83
94
122
188
295
441
SF4G0.5
SF4G0.75
SF4G1
SF4G1.5
SF4G2.5
SF4G4
SF4G6
6.8
8.5
8.8
9.6
11.6
14.4
17.7
62
101
115
147
228
359
535
SF5G0.5
SF5G0.75
SF5G1
SF5G1.5
SF5G2.5
SF5G4
SF5G6
9.5
10.4
13
16.2
144
187
320
479
SF7G1
SF7G1.5
SF7G2.5
SF7G4
11.5
14.6
17.8
231
314
502
SF12G1
SF12G1.5
SF12G2.5
Nominal
diameter
mm
Stranding and Current Ratings
Stranding to DIN VDE 0295, IEC 60228
Cross-section
Class 2 VDE 0295
Class 5 VDE 0295 Class 6 VDE 0295
Stranded Wires
Multi Str. Wires
Fine Wires
Extra Fine Wires
Extra Fine Wires
Extra Fine Wires
mm 2
0.05
140.07
0.08
0.09
240.07
0.14
180.1
180.1
360.07
0.25
140.15
320.1
650.07
0.34
70.25
190.15
420.1
880.07
0.38
70.27
120.2
210.15
1000.07
0.5
70.30*
70.30
160.2
280.15
1310.07
0.75
70.37
70.37
240.2
420.15
960.1
1950.07
1.0
70.43
70.43
320.2
560.15
1280.1
2600.07
1.5
70.52
70.52
300.25
840.15
1920.1
3920.07
2.5
70.67
190.41
500.25
1400.15
3200.1
6510.07
4
70.85
190.52
560.3
2240.15
5120.1
10400.07
6
71.05
190.64
840.3
1920.2
7680.1
15600.07
10
71.35
490.51
800.4
3200.2
12800.1
26000.07
16
71.70
490.65
1280.4
5120.2
20480.1
25
72.13
840.62
2000.4
8000.2
32000.1
35
72.52
1330.58
2800.4
11200.2
50
191.83
1330.69
4000.4
7050.3
70
192.17
1890.69
3560.5
9900.3
95
192.52
2590.69
4850.5
13400.3
120
372.03
3360.67
6140.5
16900.3
150
372.27
3920.69
7650.5
21230.3
185
372.52
4940.69
9440.5
14700.4
240
612.24
6270.70
12250.5
19050.4
300
612.50
7900.70
15300.5
23850.4
400
612.89
20350.5
500
613.23
17680.6
630
912.97
22280.6
*No. of wirescross-section.
Extra Fine wires
260.05
400.05
720.05
1280.05
1740.05
1940.05
2560.05
3840.05
5120.05
7680.05
12800.05
Current carrying capacity for control cables & silicone cables
Cross-section
mm 2
0.5
0.75
1
1.5
2.5
4
6
10
16
25
35
50
70
95
†
Flexible Control cables †
Ambient temp. up to 30°C
In open or ventilated conduits
A
8
11
13
16
23
30
39
54
72
95
120
150
180
220
Silicone High Temp. cables ‡
Ambient temp. up to 150°C
Single cores laid in duct
A
6
9
12
16
21
28
36
49
65
85
105
140
175
210
Single cores laid in open air
A
10
15
19
24
32
42
54
73
98
129
158
198
245
292
Multicore laid in open air
A
7
12
15
18
26
34
44
61
82
108
135
168
207
250
Multicore cables, PVC and PUR sheathed.
‡
Current ratings for ambient temperature over 150°C
Temperature
°C
up to 150°C
over 150 to 155
over 155 to 160
over 160 to 165
over 165 to 170
over 170 to 175
Current carrying capacity
%
100
91
82
71
58
41
31
Bus Technology Cables
Profibus L2
Profibus L2
Application
Construction
Fixed Indoor/Outdoor
Industry & Drag Chain
120.64mm
120.64mm Industry 120.64mm (7 wire)
120.64mm Drag Chain
120.64mm
120.65mm Stranded
Core insulation 1
Core insulation 2
Core colours
Stranding elements
Shielding 1
Shielding 2
Overall shielding
Outer sheath
External diameter
Outer sheath colour
PE
PE
PE
PE
–
–
–
–
Rd/Gn
Rd/Gn
Rd/Gn
Rd/Gn
2 cores+2 fillers
2 cores+2 fillers
2 cores+2 fillers
2 cores+2 fillers
Foil
Foil
Foil
Foil
Foil Alu lined
Foil Alu lined
Foil Alu lined
Foil Alu lined
Tinned Cu braided
Tinned Cu braided
Tinned Cu braided
Tinned Cu braided
PVC or PE
PUR
PVC
PUR & PVC
7.8 or 8.0mm
8.0mm
7.8mm
8mm
Grey, Black or Violet
Light Blue
Violet
Violet or Light Blue
150 Ohm +/– 10%
150 Ohm +/– 10%
150 Ohm +/– 10%
150 Ohm +/– 10%
55 Ohm/km max.
55 Ohm/km max.
55 Ohm/km max.
66.5 Ohm/km max.
1.0 GOhmkm min.
1.0 GOhmkm min.
1.0 GOhmkm min.
1.0 GOhmkm min.
30nF/km nom.
30nF/km nom.
30nF/km nom.
30nF/km nom.
1.5kV
1.5kV
1.5kV
1.5kV
9.6kHz <2.5dB/km
38.4kHz <4.0dB/km
4MHz <22.0dB/km
16MHz <42.0dB/km
9.6kHz <2.5dB/km
38.4kHz <4.0dB/km
4MHz <22.0dB/km
16MHz <42.0dB/km
9.6kHz <3.0dB/km
38.4kHz <5.0dB/km
4MHz <25.0dB/km
16MHz <52.0dB/km
9.6kHz <3.0dB/km
38.4kHz <5.0dB/km
4MHz <25.0dB/km
16MHz <51.0dB/km
Weight
Min. bending radius
Operating temperature
Applicable standards
International standards
70kg/km
81kg/km
55kg/km
80kg/km
120mm
120mm
110mm
100mm
–40/+70°C
–40/+70°C
–40/+70°C
–5/+60°C
Profibus DIN 19245
Profibus DIN 19245
Profibus DIN 19245
Profibus DIN 19245
UL 2571
UL 2571
UL 2571
UL1685
Product codes
OLX80384
OLX81003
OLX800648
OLX800109
OLX81448
OLX81905
OLX800649
OLX81903
OLX81906
OLX81904
BUS44475989
BUS44476389
BUS44477919
Electrical data
Characteristic impedance
Conductor resistance
Insulation resistance
Mutual capacitance
Test voltage
Attenuation
Profibus L2
7 Wire
Profibus L2
Torsion/Mobile
 Other BUS cables available include E-BUS, I-BUS, A-BUS, Industrial Ethernet, CC-Link & ProfiNet.
 For further product codes and data, contact Olex.
32
Profibus L2
CAN Bus
INTERBUS
ASI Bus
Desina
Fixed Indoor/Drag Chain Actuator/Sensor/Interface Sensor Actuator
DeviceNet
Fixed Indoor/Drag Chain
Haz./Non Hazardous
Fixed Indoor/Hi Flexible
121.0/2.55mm
120.22/0.50mm Indoor 320.22mm
410.22/0.50mm Indoor +–31mm
120.25mm Hi Flex.
410.25mm Hi Flex.
21.5mm
40.34mm
12AWG18
+–12AWG15
12AWG24
+–12AWG22
PE
PE
PE
Rubber
PP
PE
–
–
–
–
–
PVC
Rd/Gn
Wh/Bn/Gn/Ye
Wh/Bn, Gn/Rd,Ye/Gn
Bu/Bn
Wh,Bu,Bk,Bn
Light Bu/Wh
2 cores+2 fillers
Double or star quad
Double core
Star quad
Double core
Foil
Polyester foil
Polyester foil
Foil Alu lined
–
Tinned Cu braided
Tinned Cu braided
PVC
PVC
PVC & PUR
7.8mm
5.4, 7.1 or 8.5mm
7.0, 7.6 or 8.0mm
Blue or Black
Violet
Blue
100 Ohm +/– 10%
120 Ohm +/– 10%
120 Ohm +/– 10%
22 Ohm/km max.
87 Ohm/km max.
87 Ohm/km max.
13.7 Ohm/km max.
60 Ohm/km Max.
90 Ohm/km max.
1.0 GOhmkm min.
1.0 GOhmkm min.
1.0 GOhmkm min.
1.0 GOhmkm min.
1.0 GOhmkm min.
0.02 GOhmkm min.
55nF/km nom.
50–65nF/km nom.
50–65nF/km nom.
2.5kV
1.5kV
1.5kV
1.5kV
2kV
PETP fleece
EPDM, PUR & PVC
Yellow or Black
TPM
PVC & PUR
4.7mm
6.9, 7, 12 & 12.2mm
Black
Grey or Violet
120 Ohm +/– 10%
125kHz <0.42dB/100m
500kHz <0.81dB/100m
256kHz <1.5dB/100m
772kHz <2.4dB/100m
1MHz <2.7dB/100m
4MHz <5.2dB/100m
10MHz <8.4dB/100m
16MHz <11.2dB/100m
20MHz <11.9dB/100m
39kHz <3dB/km
80kg/km
B/W 38–105kg/km
B/W 70–107kg/km
70kg/km
33kg/km
192 & 67kg/km
140mm
81–128mm
110–130mm
30mm
75mm
190 & 110mm
–20/+70°C
–40/+70°C
–40/+70°C
–40/+85°C
–50/+80°C
–20/+80°C
Profibus DIN 19245
Profibus DIN 19245
Interbus Spec 1.1 & 1.2 ASI Standard
DESINA
ODVA Devicenet
UL 2571
UL 2571
UL 2571
OLX82835
OLX82836
OLX800650
OLX800715
BUS44473419
BUS44473459
OLX80778
OLX81286
OLX81287
OLX81202
OLX800571
OLX81557
OLX800685
OLX81203
OLX81911
OLX82696
OLX81912
UL 758 / CSA 214
OLX80824
OLX80825
OLX82434
OLX82822
BUS48210165
BUS48210116
33
Current Carrying Capacity for
H07VVH6-F, VCVH6-F, Rheyflat -N, Boitalyon R
®
®
Current Carrying Capacity
Nominal
Single core cable
cross-sec.
free in air in acc.
of conductor with EN 50 355
mm 2
A
XLPE or EPR
1.5
29
2.5
38
4
53
6
69
10
98
16
127
25
173
35
219
50
276
70
345
95
414
120
489
150
564
185
644
240
776
Multi core cable three
loaded cores free in air
type E in acc. with
IEC 60 364-5-52-12
A
PVC
19
25
34
43
60
80
101
126
153
196
238
276
318
362
424
Multi core cable three
loaded cores free in air
in acc. with
IEC 60 364-5-52-12
A
XLPE or EPR
23
31
42
54
75
100
127
158
192
246
298
346
395
450
538
Multi core cable three
loaded cores free on
ground in acc. with
IEC 60 364-5-52-12
A
XLPE or EPR
22
29
40
51
71
95
121
150
182
234
283
329
375
428
511
Correction factors for
ambient air temperature
Ambient
PVC
Temp.
insulation
°C
Temp: 70°C
10
1.22
15
1.17
20
1.12
25
1.06
30
1.00
35
0.94
40
0.87
45
0.79
50
0.71
55
0.61
60
0.50
65
70
75
80
XLPE or
EPR insulation
Temp: 90°C
1.15
1.12
1.08
1.04
1.00
0.96
0.91
0.87
0.82
0.76
0.71
0.65
0.58
0.50
0.41
Note Correction factor for ambient air temperature table to the right.
XLPE or EPR Conductor Temperature: 90°C / Reference ambient temperature of 30°C.
PVC Conductor Temperature: 70°C / Reference ambient temperature of 30°C.
Bending Radius
Cable application
Cable Type
Entry bell
Festoon e-chain
application
Reeling operation
Cable tender
Deflection pulleys
s-shape
deflection
BUFLEX DGR
6 x d
BUFLEX SEM
BUFLEX SC
10 x d
H07VVH6-F
PVC FLAT
RHEYFLAT-N
6 x d
6 x d
8 x d
8 x d
8 x d
20 x d
10 x d
10 x d
10 x d
15 x d
15 x d
20 x d
d = outer diameter
t = thickness
INDUSTRIAL
34
10 x t
10 x t
Contents
Instrument Cable Technology
36
Instrolex® Cable Construction
37
Instrolex® Cable Characteristics
38
Instrolex® Unscreened &
Overall Screened Pairs
39
Instrolex® Individually &
Overall Screened Pairs
40
Instrolex® Overall Screened SWA Pairs
41
Instrolex® Individually &
Overall Screened SWA Pairs
42
Instrolex® Triples
43
Instrolex
Instrumentation
®
Olex has been manufacturing instrumentation cable
in Australia for more than 40 years.
Olex instrumentation cables were re-branded in 2007 to Instrolex,®
however the cable has remained unchanged.
Olex Instrolex ® is the exact same instrumentation product you have
bought from Olex in the past, with the same product design,
technical experience and local stock support. And best of all,
Instrolex ® continues to be Australian made, as always.
So when you think instrumentation, think Olex Instrolex.®
35
Instrument Cable Technology
Instrumentation cables are required to transmit ‘clean’ signals
and another conductor. The most effective method of reducing
within industrial environments, often where there is a high level of
interference of electrostatic and electromagnetic origin is to form
electromagnetic interference through potentially hazardous areas.
the two wires carrying the instrument into a twisted pair. This
In order to achieve accurate process control, it is important that
ensures the voltages induced in the two wires are approximately
signals to and from machines are uncorrupted.
equal and opposite, so that they cancel each other out.
The challenge: Noise rejection
Additional protection against electrostatic interference is achieved
Common Mode noise occurs due to a difference in potential
by the use of a total coverage conducting screen.
between conductors used for earthing the system at different
The solution: Olex Instrolex® design
locations. This potential difference causes currents to flow in the
Olex Instrolex ® screened instrumentation cables are screened with
conductors of screens of the cable, which interfere with the signal.
a tape of aluminium-coated polyester film. For multipair applications
This type of noise is normally prevented by using a common earth
where electrostatic crosstalk is likely, such as where some pairs
for all parts of the system, prefereably at the equipment end, to
operate at higher potential than others, cables are available with the
which all circuits and screens are connected.
pairs individually screened with aluminium-coated polyester films.
Crosstalk is the transfer of signal from one pair to another in the
All screens in cables are provided with a tinned annealed copper
same cable due to electromagnetic and/or electrostatic effects.
drain wire to equalise potential along the screen and to allow easy
This is reduced by making the lay lengths with which the pairs are
connection to earth. Individual screens are electrically separated
twisted differ between adjacent pairs, so that in a long length of
from each other by a polyester separator tape to prevent circulating
cable each conductor is subject to the same influence from every
currents which could cause common mode noise.
other conductor and any induced noise is cancelled.
Transmission characteristics
The pairs and triples of Olex Instrolex ® cables are twisted to a lay
length of not more than 75mm for single pair and single triple cable.
In the multipair overall screened cables the lays are staggered to
minimise the crosstalk.
Electromagnetically induced noise is due to an induced e.m.f.
in the signal-carrying conductor due to an alternating magnetic field
such as that existing around a conductor carrying a heavy electric
current. Although such currents are generally at 50Hz, which can
be filtered out in the equipment, harmonics of very much higher
frequencies can be produced, particularly where electric motors and
welding plants are in use.
Electrostatically induced noise is due to an induced e.m.f. in
the signal-carrying conductor due to the capacitance between it
INDUSTRIAL
36
The low conductor resistance, inductance and capacitance of
Instrolex ® make it ideal for direct current and alternating current
frequencies up to 10kHz, distances of up to 10 kilometres and
low-medium speed digital transmission.
For frequencies exceeding 10kHz or for high speed data transmission
over long distances, Instrolex ® cables can be supplied with low loss
insulation materials subject to special order.
Intrinsic safety
The identification colour light blue is specified for the sheathing of
cables containing intrinsically safe circuits. Olex Instrolex ® cables
can be supplied with a light blue instead of a black sheath, subject
to special order.
Instrolex Instrumentation
Cable Construction
®
1. Plain annealed copper conductor.
OD than braid-shielded products and permits longer length.
2.Primary insulation is V-90RP which provides excellent physical
Ease of termination and freedom from insulation puncture
and electrical properties. Colour coded and numbered for easy
(such as with broken braid ends). Adjacent shields are
identification.
electrically isolated and tested in combinations.
3.Tinned copper drain wire for pair shield. Provides ease of
6.Tinned copper drain wire for overall shield provides ease
terminating shield.
of terminating shield.
4.Individual pair shields are aluminium/polyester tape. Gives
7.Ripcord simplifies field strip back without damage from
additional protection against static, noise, common mode noise
cutting tools.
and crosstalk.
8. Outer V-90RP sheath or bedding for armour.
5.Overall shield comprises aluminium/polyester tape for initial
9. Galvanised steel wire armour (optional).
protection against noise. The helically applied laminate tape
10.Outer V-90RP sheath.
shield provides 100 percent coverage while allowing a smaller
1
2
3
4
7
6
5
8
9
10
37
Instrolex Instrumentation
Cable Characteristics
®
Physical
Conductor
AWG
Conductor
size
stranding
Nominal
conductor
diameter
Nominal
insulation
thickness
Nominal
core
diameter
Nominal
screen
thickness
Drain wire
stranding
0.5
mm
no/mm
0.9
1.5
0.4
0.4
1.7
2.2
0.009
0.009
7/0.20
7/0.20
Mutual
capacitance
cond to cond
unscreened
nF/100m
8.5
11.0
Mutual
capacitance
cond to cond
screened
nF/100m
14.5
20.0
Capacitance
both wires
cond to screen
screened
nF/100m
24.0
30.0
L / R ratio
at 1000Hz
mm 2
1.5
no/mm
20
16
7/0.30
7/0.50
mm
mm
mm
Electrical
Conductor
size
mm 2
0.5
1.5
Conductor
Nominal
Maximum
resistance
voltage
current
at 20°C
rating
rating
each wire
Ohm/100m
a.c./d.c.
Amperes
3.84
110/150
3
1.36
110/150
13
Conductor
Induction
size
at
1000Hz
mm 2
µH/100m
0.5
110
1.5
95
Characteristic
impedance
at 1000Hz
unscreened
Ohm
450
350
Characteristic
impedance
at 1000Hz
screened
Ohm
350
260
Crosstalk
attenuation between
pairs @ 1000Hz
unscreened
dB/100m
100
–
Crosstalk
attenuation between
pairs @ 1000Hz
screened
dB/100m
125
–
Attenuation @ 1000Hz
between 600 Ohm
terminations
unscreened
dB/100m
0.09
0.07
µH/Ohm
15.7
36.5
Attenuation @ 1000Hz
between 600 Ohm
terminations
screened
dB/100m
0.11
0.09
Testing
Insulation integrity verified by spark test at 6kV a.c.
H.V. test on cable: between conductors and conductors to screen at 2kV a.c. for 1 minute.
Colour code
Pairs: Black and white. Each pair is numbered.
Triples: Black, white and red. Each triple is numbered.
Availability
This catalogue provides details of the standard range of instrumentation cables. Generally, these are stock items, however some items may be
subject to minimum production runs. Enquire at any Olex sales office to obtain the status of any particular item.
INDUSTRIAL
38
Instrolex Instrumentation
Unscreened &
Overall Screened Pairs
®
Construction Plain annealed copper conductor, V-90RP PVC insulated, twisted pairs, unscreened or overall screened
with aluminium polyester tape plus tinned copper drain wire, rip cord, V-90RP PVC sheathed.
Pairs
Nominal
outside
diameter
mm
Conductor 0.5mm 2 (7/0.30mm) screened
1
5.2
2
7.8
4
8.4
6
10.0
8
11.2
10
12.5
12
13.4
16
15.1
20
16.8
24
18.1
36
22.0
50
25.6
C onductor 1.5mm 2 (7/0.50mm) screened
1
6.6
2
9.9
4
10.9
6
13.0
8
14.6
10
16.3
12
17.5
16
20.0
20
22.3
24
24.1
36
29.2
50
34.2
Conductor 1.5mm 2 (7/0.30mm) unscreened
1 Pair
6.4
Minimum
bending
radius
mm
Maximum
pulling
tension
kN
Approximate
mass
Product code
kg/100m
31
47
50
60
67
75
80
91
101
109
132
153
0.07
0.14
0.28
0.42
0.56
0.70
0.84
1.12
1.40
1.68
2.52
3.50
3.5
6.3
9.4
13
17
21
24
31
38
45
66
90
IEB183AA001
IEC183AA002
IEC183AA004
IEC183AA006
IEC183AA008
IEC183AA010
IEC183AA012
IEC183AA016
IEC183AA020
IEC183AA024
IEC183AA036
IEC183AA050
40
60
65
78
88
98
105
120
134
145
175
205
0.21
0.42
0.84
1.26
1.68
2.10
2.52
3.36
4.20
5.04
7.56
10.50
6.0
11
18
26
33
41
48
63
79
93
137
188
IEB184AA001
IEC184AA002
IEC184AA004
IEC184AA006
IEC184AA008
IEC184AA010
IEC184AA012
IEC184AA016
IEC184AA020
IEC184AA024
IEC184AA036
IEC184AA050
39
0.21
5.6
IEA184AA001
39
Instrolex Instrumentation
Individually &
Overall Screened Pairs
®
Construction Plain annealed copper conductor, V-90RP PVC insulated, twisted pairs, individually and overall screened
with aluminium polyester tape plus tinned copper drain wire, rip cord, V-90RP PVC sheathed.
Pairs
Nominal
outside
diameter
mm
2
Conductor 0.5mm (7/0.30mm)
2
8.1
4
10.4
6
12.2
8
13.9
10
14.6
12
16.0
16
18.0
20
20.1
24
21.9
36
26.3
50
30.6
Conductor 1.5mm 2 (7/0.50mm)
2
10.3
4
13.4
6
16.1
8
18.2
10
19.3
12
20.9
16
23.9
20
26.5
24
29.0
36
35.1
50
40.8
Refer page 38 for electrical and physical details.
INDUSTRIAL
40
Minimum
bending
radius
mm
Maximum
pulling
tension
kN
49
62
73
84
88
96
108
120
131
158
184
0.14
0.28
0.42
0.56
0.70
0.84
1.12
1.40
1.68
2.52
3.50
62
81
97
109
116
125
143
159
174
210
245
0.42
0.84
1.26
1.68
2.10
2.52
3.36
4.20
5.04
7.56
10.50
Approximate
mass
Product code
kg/100m
7.3
12
17
22
26
31
39
48
57
83
112
IED183AA002
IED183AA004
IED183AA006
IED183AA008
IED183AA010
IED183AA012
IED183AA016
IED183AA020
IED183AA024
IED183AA036
IED183AA050
13
22
32
40
49
57
75
92
110
162
220
IED184AA002
IED184AA004
IED184AA006
IED184AA008
IED184AA010
IED184AA012
IED184AA016
IED184AA020
IED184AA024
IED184AA036
IED184AA050
Instrolex Instrumentation
Overall Screened SWA Pairs
®
Construction Plain annealed copper conductor, V-90RP PVC insulated, twisted pairs, overall screened with aluminium
polyester tape plus tinned copper drain wire, rip cord, PVC bedding, steel wire armour, V-90RP PVC sheathed.
Pairs
Nominal
over
bedding
mm
2
Conductor 0.5mm (7/0.30mm)
2
7.4
4
8.0
6
9.4
8
10.6
10
11.7
12
12.6
16
14.3
20
15.8
24
17.1
36
20.5
50
23.9
Conductor 1.5mm 2 (7/0.50mm)
1
6.2
2
9.4
4
10.3
6
12.2
8
13.8
10
15.2
12
16.5
16
18.8
20
20.8
24
22.6
36
27.7
50
32.3
Maximum
pulling
tension
kN
Approximate
mass
Product code
Nominal
over
armour
mm
Nominal
outside
diameter
mm
Minimum
bending
radius
mm
9.2
9.8
11.2
12.4
13.5
14.4
16.1
18.3
19.6
23.0
26.4
11.4
12.0
13.6
14.8
16.1
17.0
18.9
21.1
22.7
26.3
29.9
137
144
164
178
193
204
227
253
272
316
359
2.3
2.4
2.8
3.1
3.4
3.6
4.2
6.4
6.9
8.2
9.5
25
28
36
42
48
54
65
86
97
127
160
IEG183AA002
IEG183AA004
IEG183AA006
IEG183AA008
IEG183AA010
IEG183AA012
IEG183AA016
IEG183AA020
IEG183AA024
IEG183AA036
IEG183AA050
8.0
11.2
12.1
14.0
15.6
17.7
19.0
21.3
23.3
25.1
30.2
35.5
10.2
13.6
14.5
16.6
18.2
20.6
22.1
24.4
26.6
28.6
34.4
39.7
123
163
174
199
219
247
265
292
319
344
413
477
2.0
2.8
3.1
3.6
4.0
6.2
6.7
7.5
8.3
9.0
11.0
16.4
22
34
42
55
65
87
99
119
140
161
223
307
IEF184AA001
IEG184AA002
IEG184AA004
IEG184AA006
IEG184AA008
IEG184AA010
IEG184AA012
IEG184AA016
IEG184AA020
IEG184AA024
IEG184AA036
IEG184AA050
kg/100m
41
Instrolex Instrumentation
Individually &
Overall Screened SWA Pairs
®
Construction Plain annealed copper conductor, V-90RP PVC insulated, twisted pairs individually & overall screened with
aluminium polyester tape plus tinned copper drain wire, rip cord, PVC bedding, steel wire armour, V-90RP PVC sheathed.
Pairs
Nominal
over
bedding
mm
2
Conductor 0.5mm (7/0.30mm)
2
7.7
4
9.8
6
11.6
8
13.1
10
13.8
12
15.0
16
17.0
20
18.8
24
20.4
36
24.6
50
29.1
Conductor 1.5mm 2 (7/0.50mm)
2
9.7
4
12.6
6
15.1
8
17.1
10
18.1
12
19.6
16
22.4
24
27.5
Nominal
outside
diameter
mm
Minimum
bending
radius
mm
Maximum
pulling
tension
kN
Approximate
mass
9.5
11.6
13.4
14.9
15.6
16.8
19.5
21.3
22.9
27.1
31.6
11.7
14.0
16.0
17.5
18.2
19.6
22.6
24.4
26.2
30.6
35.8
141
168
192
210
219
235
271
293
315
368
430
2.4
2.9
3.4
3.8
4.0
4.3
6.9
7.5
8.2
9.8
11.5
26
35
45
52
58
66
91
104
118
155
202
IEH183AA002
IEH183AA004
IEH183AA006
IEH183AA008
IEH183AA010
IEH183AA012
IEH183AA016
IEH183AA020
IEH183AA024
IEH183AA036
IEH183AA050
11.5
14.4
17.6
19.6
20.6
22.1
24.9
30.0
13.9
17.1
20.4
22.7
23.7
25.4
28.4
33.9
167
205
245
272
284
305
341
407
2.9
3.6
6.2
6.9
7.4
7.9
9.0
11.0
36
51
78
92
103
116
143
194
IEH184AA002
IEH184AA004
IEH184AA006
IEH184AA008
IEH184AA010
IEH184AA012
IEH184AA016
IEH184AA024
Refer page 38 for electrical and physical details.
INDUSTRIAL
42
Product code
Nominal
over
armour
mm
kg/100m
Instrolex Instrumentation
Triples
®
Construction Plain annealed copper conductor, V-90RP PVC insulated, twisted triples, unscreened or overall screened
with aluminium polyester tape plus tinned copper drain wire, rip cord, V-90RP PVC sheathed.
Unscreened and Overall Screened Triples
Triples
Nominal
outside diameter
mm
Conductor 0.5mm 2 (7/0.30mm) screened
4
10.0
6
11.7
12
16.1
16
18.1
36
26.4
Conductor 1.5mm 2 (7/0.50mm) screened
1
6.9
4
13.0
6
15.6
12
21.1
16
24.1
36
35.4
Conductor 1.5mm2 (7/0.30mm) unscreened
1 Triple
6.8
Minimum
bending radius
mm
Maximum
pulling tension
kN
Approximate
mass
kg/100m
Product code
60
70
96
109
159
0.42
0.63
1.26
1.68
3.78
13
19
35
45
96
IGC183AA004
IGC183AA006
IGC183AA012
IGC183AA016
IGC183AA036
42
78
93
126
145
212
0.32
1.26
1.89
3.78
5.04
11.30
7.8
26
38
71
93
202
IGB184AA001
IGC184AA004
IGC184AA006
IGC184AA012
IGC184AA016
IGC184AA036
41
0.32
7
IGA184AA001
66
79
102
116
169
0.42
0.63
1.26
1.68
3.78
16
22
40
52
111
IGD183AA004
IGD183AA006
IGD183AA012
IGD183AA016
IGD183AA036
85
102
135
154
225
1.26
1.89
3.78
5.04
11.30
29
42
78
103
223
IGD184AA004
IGD184AA006
IGD184AA012
IGD184AA016
IGD184AA036
Individually and Overall Screened Triples
Conductor 0.5mm 2 (7/0.30mm) screened
4
11.0
6
13.1
12
17.0
16
19.4
36
28.2
Conductor 1.5mm 2 (7/0.50mm) screened
4
14.2
6
17.1
12
22.4
16
25.6
36
37.6
Overall Screened SWA Triples
Triples
Nominal diameter
over bedding
mm
Conductor 0.5mm 2 (7/0.30mm)
4
9.4
12
15.0
16
17.1
Conductor 1.5mm 2 (7/0.50mm)
1
6.6
4
12.2
12
19.8
Approximate
mass
kg/100m
Product code
Nominal diameter
over armour
mm
Nominal outside
diameter
mm
Minimum bending
radius
mm
Maximum pulling
tension
kN
11.2
16.8
19.6
13.6
19.7
22.7
164
236
272
2.8
4.3
6.9
36
70
97
IGG183AA004
IGG183AA012
IGG183AA016
8.4
14.0
22.3
10.6
16.6
25.6
127
199
307
2.0
3.6
8.0
24
55
132
IGF184AA001
IGG184AA004
IGG184AA012
14.6
21.3
23.7
175
256
284
3.1
6.5
7.4
40
88
107
IGH183AA004
IGH183AA012
IGH183AA016
17.9
26.7
214
321
3.9
8.3
60
140
IGH184AA004
IGH184AA012
Individually and Overall Screened SWA Triples
Conductor 0.5mm 2 (7/0.30mm)
4
10.4
12.2
12
15.9
18.4
16
18.1
20.6
Conductor 1.5mm 2 (7/0.50mm)
4
13.4
15.2
12
21.0
23.5
43
The Olex Cable Range
Low Voltage power and
control cables
Flexible power and
control cables
Specialised Industrial cables
Building wires
Versolex ® – XLPE/TPE
– Primary and secondary cables
Airport lighting cables:
Flats
– Power
Automation cables
PVC/PVC SDIs
– Welding
Offshore Oil and gas cables
XLPE/PVC single cores
– EMC/VSD
Defence cables – AO 14,000
PVC/PVC circulars
– Submersible
– VG cables
XLPE/PVC multicores
Flexolex ® EPR/CPE power
Armoured PVC/PVC circulars
Titanex
Rolling stock cables
Armoured XLPE/PVC multicores
PVC/PVC power
Materials handling cables
Multicore control
PVC/PVC control
Marine cables
Armoured multicore control
– Milspec cables
Wind turbine cables
Neutral screened
Data & communications cables
HV transmission cables
Aerial
Datolex ® – Security
Extra High Voltage U/G XLPE to 330kV
Varolex ® screened VSD/EMC
Fire performance cables
Pyrolex™ C eramifiable ® Fire Rated (FR)
– single core ES110
(joints, terminations, engineering services,
– Category 5e
condition monitoring)
– Coaxial
Bare overhead conductors
Gardolex™ Garden Lighting
– All Aluminium
Audiolex™ – Speaker
– All Aluminium alloy 1120
– multicore ES90
Fire Safe (FS) power
– Figure 8
– Coaxial
Fibre – Multi Mode
Rolling stock
– Single Mode
Locomotive
Telephone – Internal
Envirolex ®
– External
– ACSR
– S teel earth wire and stay wire
(galvanised or aluminium clad)
HV distribution cables
U/G XLPE to 33kV
Paper insulated lead covered to 33kV
Data
Instrolex®
Instrumentation cables
Mining cables (flexible) to‑33kV
(metallic and non-metallic screened)
Overall screened
Reeling and trailing cables
Covered Conductor
Overall screened armoured
to AS/NZS 1802 and 2802
Single Point Suspension
Individual & overall screened
Feeder cables
HV submarine cables
Individual & overall screened armoured
Machine cables
11kV to 33kV (EHV also)
Thermocouple extension wire
Aerial bundled cable XLPE to 33kV
XLPE, EPR or PILC insulation
Radial water barrier:
– A l/HDPE, LAS, stainless steel sheath
Mechanical protection:
– S ingle, double wire armour, HDPE,
hessian served
INDUSTRIAL
44
Olex reserves the right to change or vary the construction of any of their products without notice.
Every care has been taken in the printing of this publication but Olex accepts no liability of any
kind resulting from the information provided herein.
Olex Australia Pty Limited A.B.N. 61 087 542 863 Printed in Australia 6/2010 Disegno OLC4289
Olex widens
its range of
Industrial cables
Olex now has access to the Nexans range of proven industrial
products and can deliver these directly to you.
For more information on these, or any other Olex products,
please call 1300 CABLES or visit www.olex.com.au
DISEGNO OLC3105 INDUSTRIAL CATALOGUE COVER C M Y K PMS877 PMS REFLEX BLUE spot uv gloss
Australia Head Office 207 Sunshine Road Tottenham
Victoria 3012 Australia Phone 613 9281 4444
INDUSTRIAL
Cable Sales Phone 1300 CABLES
New Zealand Paraite Road Bell Block
New Plymouth New Zealand Phone 646 755 9800
www.olex.co.nz
South East Asia 401 Macpherson Road
#02-07 Hotel Windsor Singapore 368125
Phone 65 688 70200
China Room 5410 Building 4, Xiyuan Hotel
Beijing China 100044 Phone 86 10 6835 1019
For more information see
www.olex.com.au
LOW VOLTAGE
INDUSTRIAL
HIGH VOLTAGE
FIRE RATED
DATA/COMMS
MINING
a Nexans company
a Nexans company