2003 Zoning Systems

Transcription

2003 Zoning Systems
2003 Zoning Systems
THIS BOOK CONTAINS ALL INFORMATION NEEDED TO ORDER THE
FOLLOWING ZONING PRODUCTS:
EnviraCom Zoning “Zone of Greatest Demand Technology” ........
Zone Control Panels ...........................................................................
System Saver Kits...............................................................................
Zone Dampers .....................................................................................
Thermostats ........................................................................................
Accessories.........................................................................................
Zoning Demonstrators .......................................................................
Training Materials ...............................................................................
Product List of 24-Hr Delivery Status ...............................................
Zoning Control Panel Selection Guide .............................................
Technical Support...............................................................................
2
6
9
10
13
14
15
16
17
18
19
For technical support: call 1-800-TAT-Temp (1-800-828-8367).
For Internet access: www.HoneywellZoning.com
To download Zoning literature: http://hbctechlit.honeywell.com
Zone Control Panels
®U.S. Registered Trademark
Copyright © 2003 Honeywell Inc. • All RIghts Reserved
70- 0855- 2
ENVIRACOM ZONING “ZONE OF GREATEST DEMAND TECHNOLOGY”
W8835A1004 EnviraZone™ System (3H/2C)
New advanced zoning control system using the EnviraCom™
communications protocol. The most advanced and easiest to
install zoning system in the industry. New control algorithm
reduces and regulates plant cycles, decreases damper cycles,
and increases efficiency.
• Creates a networked zoning system when combined with three
T8635L Microelectronic Communicating Programmable
Thermostats.
• Expandable to nine zones with additional W8703 Damper Interface
Modules and Thermostats.
• Compatible with conventional gas, oil, electric or heat pump systems
up to 3H/2C.
• Unsurpassed ease-of-wiring with only three wires to connect
between devices.
• True communicating system using standard thermostat wire.
• Networked zoning enables these features:
— Time synchronization.
— Shared-filter indication.
— Outdoor temperature display in all zones with only one C7089B
Outdoor Temperature Sensor connected.
— Vacation Hold in all zones.
— Check LED in all zones.
— Auto-changeover by zone.
— Individual fan control in each zone.
— Selectable high and low equipment protection settings.
— Adjustable stage timing.
— Adjustable purge timing and damper positions.
— Expandable up to nine zones with W8703 Damper Interface
Module.
— Single network can use up to nine T8635L Thermostats and two
W8703 Damper Interface Modules to control nine zones.
— Telephone access when used with optional W8735B Telephone
Access Modules.
— Uses Zone of Greatest Demand Intelligence.
— Allows use of EnviraCom furnace board or traditional furnace
boards.
— Optional use of two transformers for power when many dampers
are needed.
W8835A1004
EnviraZone System Saver Kits
EnviraZone System Saver Kits contain individual components
that are required for installing your complete zoning system at a
15% cost savings: W86835A Zone Manager, C7835A Discharge
Air Temperature Sensor, plate-mounted transformer and T8635L
Thermostats.
Y8835A1002
• Y8835A is for two zone system. Kit includes two T8635L
Thermostats, one W8835A Zone Manager, one C7835A Discharge
Air Temperture Sensor and one AT140D System Transformer.
• Y8835B is for three zone system. Kit includes three T8635L
Thermostats, one W8835A Zone Manager, one C7835A Discharge
Air Temperture Sensor and one AT140D System Transformer.
Number of Zones
Y8835A1010
70-0855—2
2
Y8835A1002
2
Y8835A1010
3
ENVIRACOM ZONING “ZONE OF GREATEST DEMAND TECHNOLOGY”
T8635L1013 Microelectronic Communicating
Programmable Thermostat
Supports W8835A EnviraZone™ System for 3H/2C conventional
or heat pump applications or conventional gas, oil, heat pump or
electric applications when used with W8635A for 2H/2C
conventional applications or W8635B for 2H/1C heat pump
applications.
• Use three thermostats with required W8635A,B EIM and optional
W8703A Damper Interface Module or W8835A EnviraZone™System
to enable these features:
— Seven-day programmable.
— Programmable fan.
— On-demand/continuous backlight display.
— Filter indication timer.
— One-touch Daylight Savings Time key.
• Premier White® color.
• Required accessory (not included):
— W8635A EIM for up to 2H/2C conventional systems.
— W8635B EIM for up to 2H/1C heat pump systems.
— W8835A EnviraZone™System.
• Optional accessories:
— C7089B Outdoor Temperature Sensor for outdoor temperature
display.
— W8703A Damper Interface Module for up to three control zones.
• When combined with Networked Zoning, uses Zone of Greatest
Demand intelligence.
T8635L1013
C7835A1009 Discharge Air Temperature Sensor
A duct-mounted temperature probe used to provide capacity
control of heating and cooling equipment.
• Used only with Honeywell Networked Zoning.
• Mounts in the supply air duct to sense the delivered air temperature
and cuts off the heating or cooling when the delivered air temperature
goes above or below normal operating limits.
• Compares discharge air temperature to the room temperatures and,
if out of tolerance, a heating or cooling alert is issued.
• Requires three wires. Uses normal 18-22 gauge thermostat wire.
C7835A1009
3
70-0855—2
ENVIRACOM ZONING “ZONE OF GREATEST DEMAND TECHNOLOGY”
W8635A1006, W8635B1004 Equipment Interface Module
• W8635A controls gas, oil or electric heat conventional systems.
• W8635B controls single-stage or multi-stage heat pumps.
Check LED in all zones (W8635B for heat pumps).
W8635A1006
(conventional)
W8635B1004
(heat pump)
Provides 24 Vac control of single or multistage HVAC equipment
when used with a T8635L Microelectronic Communicating
Thermostat. The W8635A can be used with up to 2 heat/2 cool
conventional applications. The W8635B can be used with up to 2
heat/1 cool heat pump applications.
W8703A1003 Damper Interface Module
• Create a networked zoning system when combined with three
T8635L Microelectronic Communicating Programmable Thermostats
and a W8635A,B EIM. Networked zoning enables these features:
— Time synchronization.
— Shared-filter indication.
— Outdoor temperature display in all zones with only one C7089B
Outdoor Temperature Sensor connected.
— Vacation Hold in all zones.
— Check LED in all zones (with W8635B Equipment Interface
Module for heat pumps).
— System switch setting automatically changes in all zones.
— Individual fan control in each zone.
— A single network can use up to nine T8635L Thermostats and
three W8703 Damper Interface Modules to control of nine zones.
• Uses Zone of Greatest Demand intelligence.
Expand W8835A1004
EnviraZone Panel from
3 to 6 or 9 zones!
Controls up to three zones when used with T8635L
Microelectronic Communicating Programmable Thermostats and
W8635 Equipment Interface Module (EIM).
W8703A1003
ZD Series Dampers
70-0855—2
4
ENVIRACOM ZONING “ZONE OF GREATEST DEMAND TECHNOLOGY”
W8735B1003 Telephone Access Module
•
•
•
•
•
•
•
•
W8635A or B Equipment Interface Module and a W8703 Damper
Interface Module or a W8835A EnviraZone™ System for zoned
applications.
Used with a variety of applications including conventional, singlestage, multi-stage, heat pump and networked zoning.
Installs quickly and easily.
Dial-in using touch-tone phone and passcode to check the
temperature, change the status of the HVAC system, and perform
other thermostat-related functions.
Dials-out if there is an extended power outage, extreme hot/cold
temperature condition or other heating and cooling problem.
Monitors and reports HVAC performance problems using a C7835A
Discharge Air Temperature Sensor.
Calls up to three pre-designated telephone numbers (one can be
contractor monitoring) to report possible heating/cooling problems.
Gives remote control over thermostat-related functions.
Optional auxiliary sensor input for any normally-open sensor to
detect flooding, open doors or monitor other security areas.
Provides the benefits of secure, remote access to and control of
HVAC systems.
• Used with the T8635L Microelectronic Programmable Thermostat
and either a W8635A or W8635B Equipment Interface Module for
non-zoned applications. Can also be used with T8635L Thermostats,
(Qty 1)
(Qty 10)
W8735B1003
C7089B1000 Outdoor Temperature Sensor
• Senses outdoor temperature for display at the touch of a key.
• Encapsulated to protect against water and contaminants.
• Includes 60 in. leadwires.
C7089B1000
Used with T8500 and T8600 Thermostat families on models with
outdoor temperature option.
Opposed Blade and Round
Dampers
5
70-0855—2
ZONE CONTROL PANELS
TZ-4 TotalZone® Zone Control Panel (3H/2C)
Four-zone panel designed to provide first call changeover from
any zone thermostat. For most HVAC systems including singlestage and up to three stages of heating and two stages of cooling
and heat pump.
New Features
• Four zones for the price of three.
• Dual fuel capacity for add-on heat pump applications.
• Compatible with multi-stage and heat pump thermostats.
Features
• Expandable using TotalZone® Add-A-Zone™ Panels.
• Controls up to 28 zones.
• Uses any Honeywell four-wire thermostat to control any type of
equipment including the T8611G2051 Heat Pump Thermostats and
Honeywell Multistage Thermostats.
• Controls additional stages of heating and cooling based on:
— Time, adjustable from 5 to 30 minutes.
— Percent of zones calling.
— Thermostat.
• Built-in Emergency Heat switch eliminates need for expensive heat
pump thermostat on each zone to reduce total system cost.
• Zone-A-Lone™ allows zone 1 thermostat to set back all zones during
unoccupied periods.
• When opposite calls exist, the TZ panel services the mode that called
first and either satisfies that call within 20 minutes or drops it and
switches over to the opposite mode to satisfy that demand.
• When all calls are satisfied, the TZ panel allows fan operation from
any zone through the Fan switch on each thermostat.
— Setting the Fan switch to On from any thermostat turns on the fan
and closes the damper to zones with Fan switches set to Auto.
• Additional features:
— Resettable circuit breaker protects the panel.
— Visible LED indicators communicate operation.
— Adjustable stage control timer.
— Adjustable heating and cooling temperature limits for optional
C7735A1000 Discharge Air Temperature Sensor.
— Adjustable purge timings.
— Option of using two transformers for power when many dampers
are needed.
TZ-4K System Saver Kit is the one-box solution kit that
contains the TZ-4 Panel, C7735A Discharge Air
Temperature Sensor and AT140D Transformer at a
10% cost savings.
TZ-4
TZ-4K
TotalZone® Add-A-Zone™ (TAZ) Zone Control Panel
• Controls up to 32 zones
TAZ-4 adds four zones per TAZ Panel to the TZ-4 Zone
Control Panel.
TAZ-4
Zone panel used to add zones to TZ-4.
C7735A1000 Discharge Air Temperature Sensor
• Used only with Honeywell zoning solutions including TZ-3, MABS
EZ-2 and -4, and EMM-3 and EMM-3U control panels.
• Mounts in the supply air duct to sense the delivered air temperature
and cut off the heating or cooling when the delivered air temperature
goes above or below normal operating limits.
• Requires only two wires.
— Uses normal 18 to 22 gauge thermostat wire for shorter runs.
— Uses shielded cable for longer runs or when wiring near line
voltage.
• Replaces ZoneMAX Sensor.
A duct-mounted temperature probe used to provide capacity
control of the heating and cooling equipment.
C7735A1000
Zone Thermostats
70-0855—2
6
ZONE CONTROL PANELS
EMM-3U Universal Electronic MiniZone™ Panel (2H/2C)
• Optional ZoneMax Sensor or C7735A1000 Discharge Air
Temperature Sensor for capacity control.
• System and Zone LEDs indicate system status.
• Automatic zone changeover with 20-minute changeover timer.
• Individual zone fan control.
• Thermal circuit breaker protects panel and transformer from damage
if miswired.
• Purge timer protects equipment between calls for heating and
cooling.
• Uses spring-open/power-closed, spring-closed/power-open, and
power-open/power-closed dampers.
• Interfaces with single or dual transformer equipment.
• Replaces MABSEZ Series.
EMM-3UK System Saver Kit is the one-box solution kit
that contains the EMM-3U Panel, C7735A Discharge Air
Temperature Sensor, and AT140D Transformer at a
15% cost savings.
Controls single-stage, multi-stage, conventional or heat pump
heat/cool equipment and is used on two- and three-zone
applications.
• Compatible with single-stage, multi-stage, conventional or heat pump
applications.
• Uses virtually any Honeywell four-wire, single-stage, multi-stage, or
Trol-A-Temp heat pump thermostat.
EMM-3U
EMM-3UK
EMM-3 Electronic MiniZone™ Control Panel (1H/1C)
• Automatic zone changeover with 20-minute changeover timer.
• Individual zone fan control.
• Thermal circuit breaker protects panel and transformer from damage
if miswired.
• Purge timer protects equipment between calls for heating and
cooling.
• Uses spring-open/power-closed, spring-closed/power open, and
power-open/power-closed dampers.
• Interfaces with single or dual transformer equipment.
• Replaces MM2 and MM3 panels.
EMM-3K System Saver Kit is the one-box solution kit
that contains the EMM-3 Panel, C7735A Discharge Air
Temperature Sensor, and AT140D Transformer at a
20% cost savings.
Controls single-stage heat/cool equipment for two- and threezone applications.
• Uses any Honeywell four-wire thermostat.
• Optional ZoneMax Sensor or C7735A1000 for capacity control.
• SYSTEM and ZONE damper status LED indicate system status.
EMM-3
EMM-3K
AT140D1046 Plate-Mounted Transformer 40 VA
• Provides low voltage power source for any Trol-A-Temp control panel
or damper.
• Powers up to five ZD, AOBD or ARD damper motors from
one 40 VA transformer.
24-volt, 40 VA transformer.
AT140D1046
7
70-0855—2
ZONE CONTROL PANELS
T8665A Chronotherm® IV Wireless Thermostat
• Supports up to three zones with Honeywell zone panel:
— EMM-3 Electronic MiniZone™Panel.
— EMM-3U Universal Electronic MiniZone™Panel.
• Required accessory (not included):
— W8665A RF Reciever Module for 1H/1C conventional singlezone systems.
— W8665E RF Receiver Module for up to 3H/2C single stage,
multistage, or heat pump systems with up to three zones.
• Optional accessory:
— 20965A Universal Cover Plate to cover old thermostat marks.
Supports conventional gas, oil or electric applications (1H/1C)
when used with the W8665A Receiver Module (RM). Supports
single or multistage conventional gas, oil or electric applications
and heat pumps with auxiliary heat (up to 3H/2C) for up to three
zones when used with the W8665E Receiver Module and a
Honeywell zone panel.
T8665A
W8665A,E RF Receiver Modules
W8665E1000
• W8665A can be used with 1H/1C single-zone conventional
applications.
• W8665E can be used with up to three zones when used with a
Honeywell EMM-3 Electronic MiniZone™ Panel, EMM-3U Universal
Electronic MiniZone™ Panel, or TZ-4 TotalZone® Control Panel.
• Use with T8665A Chronotherm® IV Wireless Thermostat.
• Three-zone wireless control.
W8665A1009
W8665E1000
W8665A1009
Provides 24 Vac control of HVAC equipment when used with a
T8665A Chronotherm® IV Wireless Thermostat.
By-Pass Dampers
70-0855—2
8
SYSTEM SAVER KITS
TotalZone® TZ-4K System Saver Kit
• Includes all you need for a zoning system except the dampers and
thermostats.
• Kit design:
— Simplifies ordering.
— Costs less than ordering the components separately.
IMPORTANT
Does not include thermostats.
TZ-4K System Saver Kit is the one-box solution kit that
contains the TZ-4 Panel, C7735A Discharge Air Temperature Sensor and AT140D Transformer at a 10%
cost savings.
Single Kit
TZ-4K
Includes the TotalZone® Control Panel, AT140D1046 Transformer
and C7735A1000 Sensor.
EMM-3UK System Saver Kit
EMM-3UK System Saver Kit is the one-box solution kit
that contains the EMM-3U Panel, C7735A Discharge Air
Temperature Sensor and AT140D Transformer at a 15%
cost savings.
IMPORTANT
Does not include thermostats.
Single Kit
EMM-3UK
EMM-3K System Saver Kit
EMM-3K System Saver Kit is the one-box solution kit
that contains the EMM-3 Panel, C7735A Discharge Air
Temperature Sensor and AT140D Transformer at a 20%
cost savings.
IMPORTANT
Does not include thermostats.
Single Kit
EMM-3K
Zone Control Accessories
9
70-0855—2
ZONE DAMPERS
ZD Series Dampers
•
•
•
•
•
•
•
Parallel blade design for low leakage performance.
Quieter operation with fewer blades.
Simple, easy-to-wire, two-wire installation.
Reliable, strong, 24-volt spring-return motor.
Fail-safe, normally open operation.
Rated up to 1 in. wc static pressure.
Power closed/spring open.
Ordering Instructions
24-volt, spring return, power closed damper motor used to control
circulating air in heating, cooling, and ventilating systems.
• Kevlar gearing and cup-point set screw reduce wear, more than
doubling damper life.
• Adjustable minimum position stops.
• Mechanical visual position indicator for damper status.
• Riveted corners.
• Solid construction using extruded aluminum frame and blades.
6 in.
8 in.
10 in.
12 in.
• Order ZD (dimension 1) x (dimension 2). (Motor is always
mounted on dimension 2 side.)
— For example, ZD10x8 is a 10 in. x 8 in. damper with the motor on
the 8 in. side; but a ZD8x10 is a 8 in. x 10 in. damper that has the
motor on the 10 in. side.
— Note that the damper can be installed in any orientation
(mounting side can be on either the bottom or the side of the
duct).
• For replacement motor, see Accessories.
14 in. 16 in. 18 in. 20 in. 22 in. 24 in. 26 in. 28 in. 30 in. 32 in. 34 in. 36 in.
6 in.
8 in.
10 in.
12 in.
14 in.
16 in.
18 in.
20 in.
22 in.
24 in.
26 in.
28 in.
30 in.
32 in.
34 in.
36 in.
32006184-001 Filler Strip Kit
Used to install dampers in odd-sized ducts.
• Includes 1-1/8 in. x 3/4 in. adhesive-backed foam strips.
• Adhesive-backed foam strips supplied in 37 in. lengths.
• Example: for an 11x35 size damper requirement, order two kits. Cut
the strip sizes to fit and attach to the top and back of the damper.
70-0855—2
10
32006184-001
ZONE DAMPERS
Automatic Round Dampers (ARD)
• Shipped as power closed/spring return open damper, for use with
Honeywell Zoning Systems.
• Easily field-convertible to power open/spring return closed damper
when used as an independent zone or fresh air intake.
• Blade closes tightly against gasket for minimal leakage.
• Rated to operate up to 1 in. wc.
• For replacement motor, see Other Accessories.
5 in.
Round damper with 24-volt, spring-return damper motor, used to
control circulating air in heating, cooling, and ventilating
systems.
New Features for 2002
•
•
•
•
6 in.
7 in.
8 in.
9 in.
Kevlar gearing reduces wear, more than doubling damper life.
Adjustable minimum position stops.
Mechanical visual position indicator for damper status.
Heavier blade construction for longer life.
10 in.
12 in.
Features
14 in.
• A galvanized steel damper in a complete range of sizes.
• Single-blade damper.
16 in.
18 in.
Modulating Automatic Round Damper (MARD)
5 in.
6 in.
7 in.
8 in.
9 in.
10 in.
Single-blade modulating round damper.
12 in.
• Uses 90-second open to closed motor.
• Can be used as a zone damper.
• For replacement motor, see Other Accessories.
14 in.
16 in.
18 in.
Replacement Motor
Part No.
ML6161B2024
Description
Replacement Motor for
MARD
Static Pressure Control (SPC)
• Operates from 0.1 to 4.0 in. wc with fixed differential.
• On pressure rise, modulates damper open; on pressure fall,
modulates damper closed.
• Use with MARD for round ductwork or CDO-51 for rectangular
ductwork.
Used to sense supply air static pressure and control MARD to
maintain a set system pressure.
SPC
11
70-0855—2
ZONE DAMPERS
Static Pressure Regulating Damper (SPRD)
• New longer adjustment arm allows greater control.
• For replacement arm and weight, see Other Accessories.
Rectangular and Square Sizes
Single-blade, steel barometric damper used to bypass excess air
when majority of zone dampers are closed.
• Counter-balanced weighted arm to control bypass air for zoned
systems.
• Available in rectangular/square and round sizes.
• Air pressure in duct system increases as zone dampers close,
pushing the SPRD open automatically.
• Arm and weight both adjustable to control amount of air bypassed.
• Recommended for low pressure systems with less than 0.5 in. wc.
• Additional weights can be ordered separately.
• For larger systems and tighter pressure control, use modulating
dampers and static pressure controller (SPC).
cfm
12 in. x 8 in.
1,000
12 in. x 10 in.
1,200
12 in. x 12 in.
1,400
20 in. x 8 in.
1,600
20 in. x 10 in.
2,000
20 in. x 12 in.
3,000
Round Sizes
7 in.
300
8 in.
400
9 in.
600
10 in.
750
12 in.
1,200
14 in.
1,800
16 in.
2,400
SPRD Replacement Accessories
Accessories and Replacement Parts
Part No.
Description
32005689-001
SPRDARM-6 inch
32005689-002
SPRDARM-8 inch
32005689-003
SPRDARM-10 inch
32005689-004
SPRDARM-12 inch
32005688-001
SPRD Weight
Using A By-Pass Damper
In these applications, a damper is used to bypass excess
airflow from the supply duct into the return duct or into a dump
zone. On systems up to five tons, a Static Pressure
Regulating Damper (SPRD) is used; on larger systems, a
Modulating Automatic Round Damper (MARD) is used with a
Static Pressure Switch (SPC) for static pressure regulation.
Size supply duct systems to handle the total airflow when all
zones are open while using a damper to bypass any excess
air when only the smallest zone is calling. Bypass the excess
air into the return air duct or dump it into a hallway, false
ceiling, or basement. Size the bypass by subtracting the cfm
of the smallest zone from the total system cfm. For example,
on a four-ton (1600 cfm) system, with the smallest zone
designed to handle only 300 cfm, the bypass must be
designed to handle 1300 cfm airflow.
70-0855—2
12
CFM system – CFM smallest zone = CFM bypass
As the zone dampers open, the air pressure in the system
decreases. This reduction of air pressure automatically closes
the SPRD. As zone dampers close, the air pressure increases
and the SPRD automatically opens, bypassing the excess
airflow from the system.
This method of duct design is also a great way to control
excess humidity in the home, especially in Southern climates.
Bypassing air from the supply duct into the return duct
accelerates the dehumidification ability of the equipment,
creating greater homeowner comfort.
Fresh Air Controls
THERMOSTATS
T8601D2027 Programmable Setback Thermostat
• Can be used only on zone 1 of Mini-Zone™ System and on any zone
of TZ-3, TZ-4, EMM-3 or EMM-3U Systems.
• Requires minimum of five and maximum of nine wires, depending on
system controlled and features used.
• 24-volt power from control panel.
• Requires no batteries.
• White color.
• Terminals W, R, Y, O, G, B, C, OC, OC, OT, OT.
Single-stage setback thermostat for heating and cooling. Fieldconfigurable for manual or automatic changeover.
• Built-in occupied/unoccupied terminals control Zone-A-Lone™ TZ-3
feature.
T8601D2027
T8611G2051 Heat Pump Programmable Setback Thermostat
•
•
•
•
Provides zone control of second stage heating and emergency heat.
Field-configurable for manual or automatic changeover.
24-volt power from control panel and requires no batteries.
Requires maximum of nine wires.
T8611G2051
Heat pump, 7-day programmable setback thermostat for use on
any zone of a TotalZone or EMM-3U Honeywell Heat Pump system.
Freeze Protection Control (FPC)
• Breaks Y circuit to compressor below 36°F and remakes it at 46°F.
FPC
Protects air conditioning coil from freezing due to low airflow or
excessive bypass air.
Motor Switch Terminal (MSTN)
MSTN
Replacement actuator used with all AOBD, AOBD-BM, IOBD,
SRTD, MVRH, MVRV, ARCD and ASCD models.
Plug-In Replacement Relay (PIRR)
• Four-pole, double throw, plug-in relay.
Can be used as spare or replacement for any plug-in relay on any
Mini-Zone, older style Mastertrol panel or accessory relay control
panel.
13
PIRR
70-0855—2
ACCESSORIES
Four-Pole, Double-Throw Relay (4PDT-R)
4PDT-R
Relay and socket for use in multiple applications.
• Replaceable plug-in relay system control.
M847D Replacement Damper Motor Actuator
M847D1012
Replacement motor for ZD and ARD series dampers.
Slave Damper Control Relay (SDCR)
• Controls up to four dampers.
• Use multiple relays to control any number of dampers.
• Recommend one PMT-40 for each relay.
Used when three or more dampers are simultaneously controlled
with single switch, thermostat or zone control panel.
SDCR
Timed Make-up Air Control (TMACII)
• Opens motorized damper and turns on HVAC fan to draw in outside
air for building circulation.
• Low-voltage contacts activate exhaust fan or auxiliary controls.
• Timer face accessible from control front without opening cover.
• Meets ventilation codes in Washington, Oregon and Montana.
24-volt control used to provide programmed intake of outdoor air.
• 24-hour timer can be set in minimum 15-minute intervals.
TMACII
Timed Ventilation Control (TVC)
• Opens motorized damper and turns on HVAC fan to draw in outside
air for building circulation.
• Line voltage contacts activate exhaust fan or auxiliary control.
• Timer face accessible from control front without opening cover.
• Meets ventilation codes in Washington, Oregon and Montana.
• UL approved.
Line voltage control used to provide programmed intake of
outdoor air.
TVC
• 24-hour timer can be set in minimum 15-minute intervals.
AG Inventory
70-0855—2
14
ZONING DEMONSTRATORS
DSP3525 Zoning Demonstrator
and C7735A100 DATS, and T84 Thermostat. A T8665A1002 RF
Thermostat is included but not attached.
• Available as Suitcase (S) model that includes tabletop model and
case or Countertop (C) model (be sure to order correct model).
• Countertop model fits into existing DSP3524 suitcase.
New in 2003
DSP3525-S
DSP3525-C
• Includes TZ-4 Control Panel, W8665E1000 RF Receiver Module (3zone), ARD (5 in.) and ZD (8x) Dampers, AT140D1046 Transformer
DSP3540 Zoning Countertop Demonstrator
DSP3540
DSP3541 Zoning Countertop Demonstrator
• Includes EMM-3U; T8601, T8400 and T8001 Thermostats; three
dampers, C7735A Discharge Air Temperature Sensor and system
indicator panel.
• Attractive display panel.
• Includes EMM-3; T8601, T8400 and T8001 Thermostats; three
dampers, C7735A Discharge Air Temperature Sensor and system
indicator panel.
• Attractive display panel.
• New for 2003: two ARD dampers and one ZD damper.
New in 2003
DSP3541
DSP3580 Networked Zoning Suitcase Demonstrator
• Includes T8635 Thermostat, W8635A, W8635B Equipment Interface
Modules; and W8703 Damper Interface Module and W8735B
Telephone Access Module.
• Convenient suitcase design.
DSP3580
15
70-0855—2
TRAINING MATERIALS
Training Materials
Item
Number
Literature Training Envelope
50-8701
Zoning Systems Reference Manual (Binder)
63-7067
Contractor Networked Zoning Video
VH-090
Homeowner Networked Zoning Video
VH-091
Zoning Training CD
63-E7120
Forced Air Zoning System Design Manual
69-1547
Zoning
Reference
Manual
Zoning
Training CD
Copyright © Honeywell 2002
63-E7120
10-02
http:/customer.honeywell.com
M20868
by Honeywell
M20869
70-0855—2
16
PRODUCT LIST OF 24-HR DELIVERY STATUS
STOCKED INVENTORY (ALL ITEMS CAN SHIP WITHIN 24 HOURS)
EnviraZone Products
T8635L1013
W8635A1006
W8635B1004
W8703A1003
W8735B1003
C7835A1009
W8835A1004
Y8835A1002
Y8835A1010
ARD7
ARD16
ARD8
ARD18
ARD9
ARD10
MARD6
MARD14
MARD7
MARD16
MARD8
MARD18
MARD9
MARD10
ZD8X10
ZD8X22
ZD10X14
ZD12X10
ZD14x8
ZD16X12
ZD20x8
ZD24x10
ZD8X12
ZD8X24
ZD10X16
ZD12x12
ZD14x10
ZD16x14
ZD20x10
ZD30x8
ZD8X14
ZD8x30
ZD10X18
ZD12X14
ZD14x12
ZD16x16
ZD20X12
ZD8X16
ZD10X8
ZD10X20
ZD12x16
ZD14x14
ZD18x8
ZD20x14
ZD8X18
ZD10X10
ZD10X24
ZD12x18
ZD16x8
ZD18x10
ZD22x8
SPRD9
SPRD12X8
SPRD10
SPRD12X10
SPRD12
SPRD12x12
C7735A1000
MSTN
PIRR
Zoning Control Panels
TZ-4
TAZ-4
EMM-3
EMM-3U
Thermostats and Subbases
T8601D2027
T8611G2051
MARD Dampers (Round)
ARD5
ARD12
ARD6
ARD14
ARD Dampers (Round/Modulating)
MARD5
MARD12
ZD Dampers
ZD8X8
ZD8X20
ZD10X12
ZD12X8
ZD12x20
ZD16x10
ZD18x12
ZD24x8
Static Pressure Regulating Dampers (Round and Rectangular)
SPRD6
SPRD14
SPRD20X8
SPRD7
SPRD16
SPRD20x10
SPRD8
SPRD20X12
EMM-3UK
EMM-3K
Zoning Kits
TZ-4K
Accessories/Miscellaneous
4PDT-R
SDCR
FPC
SPC
AT140AD1046
17
70-0855—2
ZONING CONTROL PANEL SELECTION GUIDE
ZONING CONTROL PANEL SELECTION GUIDE
CONVENTIONAL ZONE PANEL SELECTION GUIDE
APPLICATION
AUTOMATIC
CHANGEOVER
USES ANY 4-WIRE THERMOSTAT
CAPABLE UP TO 32 ZONES
AUTOMATIC
CHANGEOVER
USES ANY 4-WIRE THERMOSTAT
SINGLE STAGE
MULTISTAGE
HEAT PUMP
1-HEAT/1-COOL
2-HEAT/2-COOL
2-HEAT/1-COOL
HEAT PUMP/
MULTI-STAGE
3-HEAT/2-COOL OR
DUAL FUEL 2 HEAT/2-COOL
TZ-4 TOTALZONE
TZ-4 TOTALZONE
TZ-4 TOTALZONE
TZ-4 TOTALZONE
ORDER TAZ PANELS
WHEN MORE THAN
4 ZONES ARE REQUIRED
ORDER TAZ PANELS
WHEN MORE THAN
4 ZONES ARE REQUIRED
ORDER TAZ PANELS
WHEN MORE THAN
4 ZONES ARE REQUIRED
ORDER TAZ PANELS
WHEN MORE THAN
4 ZONES ARE REQUIRED
EMM-3U
UNIVERSAL
ELECTRONIC MINIZONE
(UP TO 2-HEAT/2-COOL)
EMM-3
ELECTRONIC MINIZONE
UNIVERSAL
ELECTRONIC MINIZONE
EMM-3U
M20865
EnviraCom ZONING SELECTION GUIDE
CONVENTIONAL/
HEAT PUMP
AUTOCHANGEOVER
SINGLE STAGE
MULTISTAGE
HEAT PUMP
1-HEAT/1-COOL
2-HEAT/2-COOL
2-HEAT/1-COOL
THERMOSTAT
T8635L1013
T8635L1013
T8635L1013
T8635L1013
EQUIPMENT INTERFACE
MODULE
W8635A1006
W8635A1006
W8635B1004
W8835A1004
APPLICATION
DAMPER INTERFACE
MODULE
UP TO 9 ZONES TOTAL
3-HEAT/2-COOL
USE EnviraCom
THERMOSTATS
W8703A1003
W8703A1003
W8703A1003
3 ZONES EACH
3 ZONES EACH
3 ZONES EACH
INCLUDED WITH W8835A
FOR ZONES 1-3
ONE W8703A FOR EVERY
3 ZONES FROM 4-9
DISCHARGE AIR
TEMPERATURE SENSOR
DATS
C7835A1009
C7835A1009
C7835A1009
C7835A1009
TELEPHONE
ACCESS MODULE
W8635B1003
W8635B1003
W8635B1003
W8635B1003
M20866
70-0855—2
18
TECHNICAL SUPPORT
ZONING SIMPLIFIED TECHNICAL SUPPORT
Call 1-800-TAT-Temp (1-800-828-8367) for Honeywell Zoning technical support.
Call Dave, Nick and Arnie for all your zoning needs.
Benefit from more than 20 years of HVAC experience!
For Internet access:
www.honeywellzoning.com
To download Zoning literature:
http://hbctechlit.honeywell.com
19
70-0855—2
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
70-0855—2 G.H.
Rev 1-03
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario
M1V 4Z9
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer paper fibers.
www.honeywell.com/yourhome