2003 Zoning Systems
Transcription
2003 Zoning Systems
2003 Zoning Systems THIS BOOK CONTAINS ALL INFORMATION NEEDED TO ORDER THE FOLLOWING ZONING PRODUCTS: EnviraCom Zoning “Zone of Greatest Demand Technology” ........ Zone Control Panels ........................................................................... System Saver Kits............................................................................... Zone Dampers ..................................................................................... Thermostats ........................................................................................ Accessories......................................................................................... Zoning Demonstrators ....................................................................... Training Materials ............................................................................... Product List of 24-Hr Delivery Status ............................................... Zoning Control Panel Selection Guide ............................................. Technical Support............................................................................... 2 6 9 10 13 14 15 16 17 18 19 For technical support: call 1-800-TAT-Temp (1-800-828-8367). For Internet access: www.HoneywellZoning.com To download Zoning literature: http://hbctechlit.honeywell.com Zone Control Panels ®U.S. Registered Trademark Copyright © 2003 Honeywell Inc. • All RIghts Reserved 70- 0855- 2 ENVIRACOM ZONING “ZONE OF GREATEST DEMAND TECHNOLOGY” W8835A1004 EnviraZone™ System (3H/2C) New advanced zoning control system using the EnviraCom™ communications protocol. The most advanced and easiest to install zoning system in the industry. New control algorithm reduces and regulates plant cycles, decreases damper cycles, and increases efficiency. • Creates a networked zoning system when combined with three T8635L Microelectronic Communicating Programmable Thermostats. • Expandable to nine zones with additional W8703 Damper Interface Modules and Thermostats. • Compatible with conventional gas, oil, electric or heat pump systems up to 3H/2C. • Unsurpassed ease-of-wiring with only three wires to connect between devices. • True communicating system using standard thermostat wire. • Networked zoning enables these features: — Time synchronization. — Shared-filter indication. — Outdoor temperature display in all zones with only one C7089B Outdoor Temperature Sensor connected. — Vacation Hold in all zones. — Check LED in all zones. — Auto-changeover by zone. — Individual fan control in each zone. — Selectable high and low equipment protection settings. — Adjustable stage timing. — Adjustable purge timing and damper positions. — Expandable up to nine zones with W8703 Damper Interface Module. — Single network can use up to nine T8635L Thermostats and two W8703 Damper Interface Modules to control nine zones. — Telephone access when used with optional W8735B Telephone Access Modules. — Uses Zone of Greatest Demand Intelligence. — Allows use of EnviraCom furnace board or traditional furnace boards. — Optional use of two transformers for power when many dampers are needed. W8835A1004 EnviraZone System Saver Kits EnviraZone System Saver Kits contain individual components that are required for installing your complete zoning system at a 15% cost savings: W86835A Zone Manager, C7835A Discharge Air Temperature Sensor, plate-mounted transformer and T8635L Thermostats. Y8835A1002 • Y8835A is for two zone system. Kit includes two T8635L Thermostats, one W8835A Zone Manager, one C7835A Discharge Air Temperture Sensor and one AT140D System Transformer. • Y8835B is for three zone system. Kit includes three T8635L Thermostats, one W8835A Zone Manager, one C7835A Discharge Air Temperture Sensor and one AT140D System Transformer. Number of Zones Y8835A1010 70-0855—2 2 Y8835A1002 2 Y8835A1010 3 ENVIRACOM ZONING “ZONE OF GREATEST DEMAND TECHNOLOGY” T8635L1013 Microelectronic Communicating Programmable Thermostat Supports W8835A EnviraZone™ System for 3H/2C conventional or heat pump applications or conventional gas, oil, heat pump or electric applications when used with W8635A for 2H/2C conventional applications or W8635B for 2H/1C heat pump applications. • Use three thermostats with required W8635A,B EIM and optional W8703A Damper Interface Module or W8835A EnviraZone™System to enable these features: — Seven-day programmable. — Programmable fan. — On-demand/continuous backlight display. — Filter indication timer. — One-touch Daylight Savings Time key. • Premier White® color. • Required accessory (not included): — W8635A EIM for up to 2H/2C conventional systems. — W8635B EIM for up to 2H/1C heat pump systems. — W8835A EnviraZone™System. • Optional accessories: — C7089B Outdoor Temperature Sensor for outdoor temperature display. — W8703A Damper Interface Module for up to three control zones. • When combined with Networked Zoning, uses Zone of Greatest Demand intelligence. T8635L1013 C7835A1009 Discharge Air Temperature Sensor A duct-mounted temperature probe used to provide capacity control of heating and cooling equipment. • Used only with Honeywell Networked Zoning. • Mounts in the supply air duct to sense the delivered air temperature and cuts off the heating or cooling when the delivered air temperature goes above or below normal operating limits. • Compares discharge air temperature to the room temperatures and, if out of tolerance, a heating or cooling alert is issued. • Requires three wires. Uses normal 18-22 gauge thermostat wire. C7835A1009 3 70-0855—2 ENVIRACOM ZONING “ZONE OF GREATEST DEMAND TECHNOLOGY” W8635A1006, W8635B1004 Equipment Interface Module • W8635A controls gas, oil or electric heat conventional systems. • W8635B controls single-stage or multi-stage heat pumps. Check LED in all zones (W8635B for heat pumps). W8635A1006 (conventional) W8635B1004 (heat pump) Provides 24 Vac control of single or multistage HVAC equipment when used with a T8635L Microelectronic Communicating Thermostat. The W8635A can be used with up to 2 heat/2 cool conventional applications. The W8635B can be used with up to 2 heat/1 cool heat pump applications. W8703A1003 Damper Interface Module • Create a networked zoning system when combined with three T8635L Microelectronic Communicating Programmable Thermostats and a W8635A,B EIM. Networked zoning enables these features: — Time synchronization. — Shared-filter indication. — Outdoor temperature display in all zones with only one C7089B Outdoor Temperature Sensor connected. — Vacation Hold in all zones. — Check LED in all zones (with W8635B Equipment Interface Module for heat pumps). — System switch setting automatically changes in all zones. — Individual fan control in each zone. — A single network can use up to nine T8635L Thermostats and three W8703 Damper Interface Modules to control of nine zones. • Uses Zone of Greatest Demand intelligence. Expand W8835A1004 EnviraZone Panel from 3 to 6 or 9 zones! Controls up to three zones when used with T8635L Microelectronic Communicating Programmable Thermostats and W8635 Equipment Interface Module (EIM). W8703A1003 ZD Series Dampers 70-0855—2 4 ENVIRACOM ZONING “ZONE OF GREATEST DEMAND TECHNOLOGY” W8735B1003 Telephone Access Module • • • • • • • • W8635A or B Equipment Interface Module and a W8703 Damper Interface Module or a W8835A EnviraZone™ System for zoned applications. Used with a variety of applications including conventional, singlestage, multi-stage, heat pump and networked zoning. Installs quickly and easily. Dial-in using touch-tone phone and passcode to check the temperature, change the status of the HVAC system, and perform other thermostat-related functions. Dials-out if there is an extended power outage, extreme hot/cold temperature condition or other heating and cooling problem. Monitors and reports HVAC performance problems using a C7835A Discharge Air Temperature Sensor. Calls up to three pre-designated telephone numbers (one can be contractor monitoring) to report possible heating/cooling problems. Gives remote control over thermostat-related functions. Optional auxiliary sensor input for any normally-open sensor to detect flooding, open doors or monitor other security areas. Provides the benefits of secure, remote access to and control of HVAC systems. • Used with the T8635L Microelectronic Programmable Thermostat and either a W8635A or W8635B Equipment Interface Module for non-zoned applications. Can also be used with T8635L Thermostats, (Qty 1) (Qty 10) W8735B1003 C7089B1000 Outdoor Temperature Sensor • Senses outdoor temperature for display at the touch of a key. • Encapsulated to protect against water and contaminants. • Includes 60 in. leadwires. C7089B1000 Used with T8500 and T8600 Thermostat families on models with outdoor temperature option. Opposed Blade and Round Dampers 5 70-0855—2 ZONE CONTROL PANELS TZ-4 TotalZone® Zone Control Panel (3H/2C) Four-zone panel designed to provide first call changeover from any zone thermostat. For most HVAC systems including singlestage and up to three stages of heating and two stages of cooling and heat pump. New Features • Four zones for the price of three. • Dual fuel capacity for add-on heat pump applications. • Compatible with multi-stage and heat pump thermostats. Features • Expandable using TotalZone® Add-A-Zone™ Panels. • Controls up to 28 zones. • Uses any Honeywell four-wire thermostat to control any type of equipment including the T8611G2051 Heat Pump Thermostats and Honeywell Multistage Thermostats. • Controls additional stages of heating and cooling based on: — Time, adjustable from 5 to 30 minutes. — Percent of zones calling. — Thermostat. • Built-in Emergency Heat switch eliminates need for expensive heat pump thermostat on each zone to reduce total system cost. • Zone-A-Lone™ allows zone 1 thermostat to set back all zones during unoccupied periods. • When opposite calls exist, the TZ panel services the mode that called first and either satisfies that call within 20 minutes or drops it and switches over to the opposite mode to satisfy that demand. • When all calls are satisfied, the TZ panel allows fan operation from any zone through the Fan switch on each thermostat. — Setting the Fan switch to On from any thermostat turns on the fan and closes the damper to zones with Fan switches set to Auto. • Additional features: — Resettable circuit breaker protects the panel. — Visible LED indicators communicate operation. — Adjustable stage control timer. — Adjustable heating and cooling temperature limits for optional C7735A1000 Discharge Air Temperature Sensor. — Adjustable purge timings. — Option of using two transformers for power when many dampers are needed. TZ-4K System Saver Kit is the one-box solution kit that contains the TZ-4 Panel, C7735A Discharge Air Temperature Sensor and AT140D Transformer at a 10% cost savings. TZ-4 TZ-4K TotalZone® Add-A-Zone™ (TAZ) Zone Control Panel • Controls up to 32 zones TAZ-4 adds four zones per TAZ Panel to the TZ-4 Zone Control Panel. TAZ-4 Zone panel used to add zones to TZ-4. C7735A1000 Discharge Air Temperature Sensor • Used only with Honeywell zoning solutions including TZ-3, MABS EZ-2 and -4, and EMM-3 and EMM-3U control panels. • Mounts in the supply air duct to sense the delivered air temperature and cut off the heating or cooling when the delivered air temperature goes above or below normal operating limits. • Requires only two wires. — Uses normal 18 to 22 gauge thermostat wire for shorter runs. — Uses shielded cable for longer runs or when wiring near line voltage. • Replaces ZoneMAX Sensor. A duct-mounted temperature probe used to provide capacity control of the heating and cooling equipment. C7735A1000 Zone Thermostats 70-0855—2 6 ZONE CONTROL PANELS EMM-3U Universal Electronic MiniZone™ Panel (2H/2C) • Optional ZoneMax Sensor or C7735A1000 Discharge Air Temperature Sensor for capacity control. • System and Zone LEDs indicate system status. • Automatic zone changeover with 20-minute changeover timer. • Individual zone fan control. • Thermal circuit breaker protects panel and transformer from damage if miswired. • Purge timer protects equipment between calls for heating and cooling. • Uses spring-open/power-closed, spring-closed/power-open, and power-open/power-closed dampers. • Interfaces with single or dual transformer equipment. • Replaces MABSEZ Series. EMM-3UK System Saver Kit is the one-box solution kit that contains the EMM-3U Panel, C7735A Discharge Air Temperature Sensor, and AT140D Transformer at a 15% cost savings. Controls single-stage, multi-stage, conventional or heat pump heat/cool equipment and is used on two- and three-zone applications. • Compatible with single-stage, multi-stage, conventional or heat pump applications. • Uses virtually any Honeywell four-wire, single-stage, multi-stage, or Trol-A-Temp heat pump thermostat. EMM-3U EMM-3UK EMM-3 Electronic MiniZone™ Control Panel (1H/1C) • Automatic zone changeover with 20-minute changeover timer. • Individual zone fan control. • Thermal circuit breaker protects panel and transformer from damage if miswired. • Purge timer protects equipment between calls for heating and cooling. • Uses spring-open/power-closed, spring-closed/power open, and power-open/power-closed dampers. • Interfaces with single or dual transformer equipment. • Replaces MM2 and MM3 panels. EMM-3K System Saver Kit is the one-box solution kit that contains the EMM-3 Panel, C7735A Discharge Air Temperature Sensor, and AT140D Transformer at a 20% cost savings. Controls single-stage heat/cool equipment for two- and threezone applications. • Uses any Honeywell four-wire thermostat. • Optional ZoneMax Sensor or C7735A1000 for capacity control. • SYSTEM and ZONE damper status LED indicate system status. EMM-3 EMM-3K AT140D1046 Plate-Mounted Transformer 40 VA • Provides low voltage power source for any Trol-A-Temp control panel or damper. • Powers up to five ZD, AOBD or ARD damper motors from one 40 VA transformer. 24-volt, 40 VA transformer. AT140D1046 7 70-0855—2 ZONE CONTROL PANELS T8665A Chronotherm® IV Wireless Thermostat • Supports up to three zones with Honeywell zone panel: — EMM-3 Electronic MiniZone™Panel. — EMM-3U Universal Electronic MiniZone™Panel. • Required accessory (not included): — W8665A RF Reciever Module for 1H/1C conventional singlezone systems. — W8665E RF Receiver Module for up to 3H/2C single stage, multistage, or heat pump systems with up to three zones. • Optional accessory: — 20965A Universal Cover Plate to cover old thermostat marks. Supports conventional gas, oil or electric applications (1H/1C) when used with the W8665A Receiver Module (RM). Supports single or multistage conventional gas, oil or electric applications and heat pumps with auxiliary heat (up to 3H/2C) for up to three zones when used with the W8665E Receiver Module and a Honeywell zone panel. T8665A W8665A,E RF Receiver Modules W8665E1000 • W8665A can be used with 1H/1C single-zone conventional applications. • W8665E can be used with up to three zones when used with a Honeywell EMM-3 Electronic MiniZone™ Panel, EMM-3U Universal Electronic MiniZone™ Panel, or TZ-4 TotalZone® Control Panel. • Use with T8665A Chronotherm® IV Wireless Thermostat. • Three-zone wireless control. W8665A1009 W8665E1000 W8665A1009 Provides 24 Vac control of HVAC equipment when used with a T8665A Chronotherm® IV Wireless Thermostat. By-Pass Dampers 70-0855—2 8 SYSTEM SAVER KITS TotalZone® TZ-4K System Saver Kit • Includes all you need for a zoning system except the dampers and thermostats. • Kit design: — Simplifies ordering. — Costs less than ordering the components separately. IMPORTANT Does not include thermostats. TZ-4K System Saver Kit is the one-box solution kit that contains the TZ-4 Panel, C7735A Discharge Air Temperature Sensor and AT140D Transformer at a 10% cost savings. Single Kit TZ-4K Includes the TotalZone® Control Panel, AT140D1046 Transformer and C7735A1000 Sensor. EMM-3UK System Saver Kit EMM-3UK System Saver Kit is the one-box solution kit that contains the EMM-3U Panel, C7735A Discharge Air Temperature Sensor and AT140D Transformer at a 15% cost savings. IMPORTANT Does not include thermostats. Single Kit EMM-3UK EMM-3K System Saver Kit EMM-3K System Saver Kit is the one-box solution kit that contains the EMM-3 Panel, C7735A Discharge Air Temperature Sensor and AT140D Transformer at a 20% cost savings. IMPORTANT Does not include thermostats. Single Kit EMM-3K Zone Control Accessories 9 70-0855—2 ZONE DAMPERS ZD Series Dampers • • • • • • • Parallel blade design for low leakage performance. Quieter operation with fewer blades. Simple, easy-to-wire, two-wire installation. Reliable, strong, 24-volt spring-return motor. Fail-safe, normally open operation. Rated up to 1 in. wc static pressure. Power closed/spring open. Ordering Instructions 24-volt, spring return, power closed damper motor used to control circulating air in heating, cooling, and ventilating systems. • Kevlar gearing and cup-point set screw reduce wear, more than doubling damper life. • Adjustable minimum position stops. • Mechanical visual position indicator for damper status. • Riveted corners. • Solid construction using extruded aluminum frame and blades. 6 in. 8 in. 10 in. 12 in. • Order ZD (dimension 1) x (dimension 2). (Motor is always mounted on dimension 2 side.) — For example, ZD10x8 is a 10 in. x 8 in. damper with the motor on the 8 in. side; but a ZD8x10 is a 8 in. x 10 in. damper that has the motor on the 10 in. side. — Note that the damper can be installed in any orientation (mounting side can be on either the bottom or the side of the duct). • For replacement motor, see Accessories. 14 in. 16 in. 18 in. 20 in. 22 in. 24 in. 26 in. 28 in. 30 in. 32 in. 34 in. 36 in. 6 in. 8 in. 10 in. 12 in. 14 in. 16 in. 18 in. 20 in. 22 in. 24 in. 26 in. 28 in. 30 in. 32 in. 34 in. 36 in. 32006184-001 Filler Strip Kit Used to install dampers in odd-sized ducts. • Includes 1-1/8 in. x 3/4 in. adhesive-backed foam strips. • Adhesive-backed foam strips supplied in 37 in. lengths. • Example: for an 11x35 size damper requirement, order two kits. Cut the strip sizes to fit and attach to the top and back of the damper. 70-0855—2 10 32006184-001 ZONE DAMPERS Automatic Round Dampers (ARD) • Shipped as power closed/spring return open damper, for use with Honeywell Zoning Systems. • Easily field-convertible to power open/spring return closed damper when used as an independent zone or fresh air intake. • Blade closes tightly against gasket for minimal leakage. • Rated to operate up to 1 in. wc. • For replacement motor, see Other Accessories. 5 in. Round damper with 24-volt, spring-return damper motor, used to control circulating air in heating, cooling, and ventilating systems. New Features for 2002 • • • • 6 in. 7 in. 8 in. 9 in. Kevlar gearing reduces wear, more than doubling damper life. Adjustable minimum position stops. Mechanical visual position indicator for damper status. Heavier blade construction for longer life. 10 in. 12 in. Features 14 in. • A galvanized steel damper in a complete range of sizes. • Single-blade damper. 16 in. 18 in. Modulating Automatic Round Damper (MARD) 5 in. 6 in. 7 in. 8 in. 9 in. 10 in. Single-blade modulating round damper. 12 in. • Uses 90-second open to closed motor. • Can be used as a zone damper. • For replacement motor, see Other Accessories. 14 in. 16 in. 18 in. Replacement Motor Part No. ML6161B2024 Description Replacement Motor for MARD Static Pressure Control (SPC) • Operates from 0.1 to 4.0 in. wc with fixed differential. • On pressure rise, modulates damper open; on pressure fall, modulates damper closed. • Use with MARD for round ductwork or CDO-51 for rectangular ductwork. Used to sense supply air static pressure and control MARD to maintain a set system pressure. SPC 11 70-0855—2 ZONE DAMPERS Static Pressure Regulating Damper (SPRD) • New longer adjustment arm allows greater control. • For replacement arm and weight, see Other Accessories. Rectangular and Square Sizes Single-blade, steel barometric damper used to bypass excess air when majority of zone dampers are closed. • Counter-balanced weighted arm to control bypass air for zoned systems. • Available in rectangular/square and round sizes. • Air pressure in duct system increases as zone dampers close, pushing the SPRD open automatically. • Arm and weight both adjustable to control amount of air bypassed. • Recommended for low pressure systems with less than 0.5 in. wc. • Additional weights can be ordered separately. • For larger systems and tighter pressure control, use modulating dampers and static pressure controller (SPC). cfm 12 in. x 8 in. 1,000 12 in. x 10 in. 1,200 12 in. x 12 in. 1,400 20 in. x 8 in. 1,600 20 in. x 10 in. 2,000 20 in. x 12 in. 3,000 Round Sizes 7 in. 300 8 in. 400 9 in. 600 10 in. 750 12 in. 1,200 14 in. 1,800 16 in. 2,400 SPRD Replacement Accessories Accessories and Replacement Parts Part No. Description 32005689-001 SPRDARM-6 inch 32005689-002 SPRDARM-8 inch 32005689-003 SPRDARM-10 inch 32005689-004 SPRDARM-12 inch 32005688-001 SPRD Weight Using A By-Pass Damper In these applications, a damper is used to bypass excess airflow from the supply duct into the return duct or into a dump zone. On systems up to five tons, a Static Pressure Regulating Damper (SPRD) is used; on larger systems, a Modulating Automatic Round Damper (MARD) is used with a Static Pressure Switch (SPC) for static pressure regulation. Size supply duct systems to handle the total airflow when all zones are open while using a damper to bypass any excess air when only the smallest zone is calling. Bypass the excess air into the return air duct or dump it into a hallway, false ceiling, or basement. Size the bypass by subtracting the cfm of the smallest zone from the total system cfm. For example, on a four-ton (1600 cfm) system, with the smallest zone designed to handle only 300 cfm, the bypass must be designed to handle 1300 cfm airflow. 70-0855—2 12 CFM system – CFM smallest zone = CFM bypass As the zone dampers open, the air pressure in the system decreases. This reduction of air pressure automatically closes the SPRD. As zone dampers close, the air pressure increases and the SPRD automatically opens, bypassing the excess airflow from the system. This method of duct design is also a great way to control excess humidity in the home, especially in Southern climates. Bypassing air from the supply duct into the return duct accelerates the dehumidification ability of the equipment, creating greater homeowner comfort. Fresh Air Controls THERMOSTATS T8601D2027 Programmable Setback Thermostat • Can be used only on zone 1 of Mini-Zone™ System and on any zone of TZ-3, TZ-4, EMM-3 or EMM-3U Systems. • Requires minimum of five and maximum of nine wires, depending on system controlled and features used. • 24-volt power from control panel. • Requires no batteries. • White color. • Terminals W, R, Y, O, G, B, C, OC, OC, OT, OT. Single-stage setback thermostat for heating and cooling. Fieldconfigurable for manual or automatic changeover. • Built-in occupied/unoccupied terminals control Zone-A-Lone™ TZ-3 feature. T8601D2027 T8611G2051 Heat Pump Programmable Setback Thermostat • • • • Provides zone control of second stage heating and emergency heat. Field-configurable for manual or automatic changeover. 24-volt power from control panel and requires no batteries. Requires maximum of nine wires. T8611G2051 Heat pump, 7-day programmable setback thermostat for use on any zone of a TotalZone or EMM-3U Honeywell Heat Pump system. Freeze Protection Control (FPC) • Breaks Y circuit to compressor below 36°F and remakes it at 46°F. FPC Protects air conditioning coil from freezing due to low airflow or excessive bypass air. Motor Switch Terminal (MSTN) MSTN Replacement actuator used with all AOBD, AOBD-BM, IOBD, SRTD, MVRH, MVRV, ARCD and ASCD models. Plug-In Replacement Relay (PIRR) • Four-pole, double throw, plug-in relay. Can be used as spare or replacement for any plug-in relay on any Mini-Zone, older style Mastertrol panel or accessory relay control panel. 13 PIRR 70-0855—2 ACCESSORIES Four-Pole, Double-Throw Relay (4PDT-R) 4PDT-R Relay and socket for use in multiple applications. • Replaceable plug-in relay system control. M847D Replacement Damper Motor Actuator M847D1012 Replacement motor for ZD and ARD series dampers. Slave Damper Control Relay (SDCR) • Controls up to four dampers. • Use multiple relays to control any number of dampers. • Recommend one PMT-40 for each relay. Used when three or more dampers are simultaneously controlled with single switch, thermostat or zone control panel. SDCR Timed Make-up Air Control (TMACII) • Opens motorized damper and turns on HVAC fan to draw in outside air for building circulation. • Low-voltage contacts activate exhaust fan or auxiliary controls. • Timer face accessible from control front without opening cover. • Meets ventilation codes in Washington, Oregon and Montana. 24-volt control used to provide programmed intake of outdoor air. • 24-hour timer can be set in minimum 15-minute intervals. TMACII Timed Ventilation Control (TVC) • Opens motorized damper and turns on HVAC fan to draw in outside air for building circulation. • Line voltage contacts activate exhaust fan or auxiliary control. • Timer face accessible from control front without opening cover. • Meets ventilation codes in Washington, Oregon and Montana. • UL approved. Line voltage control used to provide programmed intake of outdoor air. TVC • 24-hour timer can be set in minimum 15-minute intervals. AG Inventory 70-0855—2 14 ZONING DEMONSTRATORS DSP3525 Zoning Demonstrator and C7735A100 DATS, and T84 Thermostat. A T8665A1002 RF Thermostat is included but not attached. • Available as Suitcase (S) model that includes tabletop model and case or Countertop (C) model (be sure to order correct model). • Countertop model fits into existing DSP3524 suitcase. New in 2003 DSP3525-S DSP3525-C • Includes TZ-4 Control Panel, W8665E1000 RF Receiver Module (3zone), ARD (5 in.) and ZD (8x) Dampers, AT140D1046 Transformer DSP3540 Zoning Countertop Demonstrator DSP3540 DSP3541 Zoning Countertop Demonstrator • Includes EMM-3U; T8601, T8400 and T8001 Thermostats; three dampers, C7735A Discharge Air Temperature Sensor and system indicator panel. • Attractive display panel. • Includes EMM-3; T8601, T8400 and T8001 Thermostats; three dampers, C7735A Discharge Air Temperature Sensor and system indicator panel. • Attractive display panel. • New for 2003: two ARD dampers and one ZD damper. New in 2003 DSP3541 DSP3580 Networked Zoning Suitcase Demonstrator • Includes T8635 Thermostat, W8635A, W8635B Equipment Interface Modules; and W8703 Damper Interface Module and W8735B Telephone Access Module. • Convenient suitcase design. DSP3580 15 70-0855—2 TRAINING MATERIALS Training Materials Item Number Literature Training Envelope 50-8701 Zoning Systems Reference Manual (Binder) 63-7067 Contractor Networked Zoning Video VH-090 Homeowner Networked Zoning Video VH-091 Zoning Training CD 63-E7120 Forced Air Zoning System Design Manual 69-1547 Zoning Reference Manual Zoning Training CD Copyright © Honeywell 2002 63-E7120 10-02 http:/customer.honeywell.com M20868 by Honeywell M20869 70-0855—2 16 PRODUCT LIST OF 24-HR DELIVERY STATUS STOCKED INVENTORY (ALL ITEMS CAN SHIP WITHIN 24 HOURS) EnviraZone Products T8635L1013 W8635A1006 W8635B1004 W8703A1003 W8735B1003 C7835A1009 W8835A1004 Y8835A1002 Y8835A1010 ARD7 ARD16 ARD8 ARD18 ARD9 ARD10 MARD6 MARD14 MARD7 MARD16 MARD8 MARD18 MARD9 MARD10 ZD8X10 ZD8X22 ZD10X14 ZD12X10 ZD14x8 ZD16X12 ZD20x8 ZD24x10 ZD8X12 ZD8X24 ZD10X16 ZD12x12 ZD14x10 ZD16x14 ZD20x10 ZD30x8 ZD8X14 ZD8x30 ZD10X18 ZD12X14 ZD14x12 ZD16x16 ZD20X12 ZD8X16 ZD10X8 ZD10X20 ZD12x16 ZD14x14 ZD18x8 ZD20x14 ZD8X18 ZD10X10 ZD10X24 ZD12x18 ZD16x8 ZD18x10 ZD22x8 SPRD9 SPRD12X8 SPRD10 SPRD12X10 SPRD12 SPRD12x12 C7735A1000 MSTN PIRR Zoning Control Panels TZ-4 TAZ-4 EMM-3 EMM-3U Thermostats and Subbases T8601D2027 T8611G2051 MARD Dampers (Round) ARD5 ARD12 ARD6 ARD14 ARD Dampers (Round/Modulating) MARD5 MARD12 ZD Dampers ZD8X8 ZD8X20 ZD10X12 ZD12X8 ZD12x20 ZD16x10 ZD18x12 ZD24x8 Static Pressure Regulating Dampers (Round and Rectangular) SPRD6 SPRD14 SPRD20X8 SPRD7 SPRD16 SPRD20x10 SPRD8 SPRD20X12 EMM-3UK EMM-3K Zoning Kits TZ-4K Accessories/Miscellaneous 4PDT-R SDCR FPC SPC AT140AD1046 17 70-0855—2 ZONING CONTROL PANEL SELECTION GUIDE ZONING CONTROL PANEL SELECTION GUIDE CONVENTIONAL ZONE PANEL SELECTION GUIDE APPLICATION AUTOMATIC CHANGEOVER USES ANY 4-WIRE THERMOSTAT CAPABLE UP TO 32 ZONES AUTOMATIC CHANGEOVER USES ANY 4-WIRE THERMOSTAT SINGLE STAGE MULTISTAGE HEAT PUMP 1-HEAT/1-COOL 2-HEAT/2-COOL 2-HEAT/1-COOL HEAT PUMP/ MULTI-STAGE 3-HEAT/2-COOL OR DUAL FUEL 2 HEAT/2-COOL TZ-4 TOTALZONE TZ-4 TOTALZONE TZ-4 TOTALZONE TZ-4 TOTALZONE ORDER TAZ PANELS WHEN MORE THAN 4 ZONES ARE REQUIRED ORDER TAZ PANELS WHEN MORE THAN 4 ZONES ARE REQUIRED ORDER TAZ PANELS WHEN MORE THAN 4 ZONES ARE REQUIRED ORDER TAZ PANELS WHEN MORE THAN 4 ZONES ARE REQUIRED EMM-3U UNIVERSAL ELECTRONIC MINIZONE (UP TO 2-HEAT/2-COOL) EMM-3 ELECTRONIC MINIZONE UNIVERSAL ELECTRONIC MINIZONE EMM-3U M20865 EnviraCom ZONING SELECTION GUIDE CONVENTIONAL/ HEAT PUMP AUTOCHANGEOVER SINGLE STAGE MULTISTAGE HEAT PUMP 1-HEAT/1-COOL 2-HEAT/2-COOL 2-HEAT/1-COOL THERMOSTAT T8635L1013 T8635L1013 T8635L1013 T8635L1013 EQUIPMENT INTERFACE MODULE W8635A1006 W8635A1006 W8635B1004 W8835A1004 APPLICATION DAMPER INTERFACE MODULE UP TO 9 ZONES TOTAL 3-HEAT/2-COOL USE EnviraCom THERMOSTATS W8703A1003 W8703A1003 W8703A1003 3 ZONES EACH 3 ZONES EACH 3 ZONES EACH INCLUDED WITH W8835A FOR ZONES 1-3 ONE W8703A FOR EVERY 3 ZONES FROM 4-9 DISCHARGE AIR TEMPERATURE SENSOR DATS C7835A1009 C7835A1009 C7835A1009 C7835A1009 TELEPHONE ACCESS MODULE W8635B1003 W8635B1003 W8635B1003 W8635B1003 M20866 70-0855—2 18 TECHNICAL SUPPORT ZONING SIMPLIFIED TECHNICAL SUPPORT Call 1-800-TAT-Temp (1-800-828-8367) for Honeywell Zoning technical support. Call Dave, Nick and Arnie for all your zoning needs. Benefit from more than 20 years of HVAC experience! For Internet access: www.honeywellzoning.com To download Zoning literature: http://hbctechlit.honeywell.com 19 70-0855—2 Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 70-0855—2 G.H. Rev 1-03 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. www.honeywell.com/yourhome