Series 25A-SY5000

Transcription

Series 25A-SY5000
Plug-in Connector Connecting Base
Type 10
Side Ported
D-sub Connector
Type 11
Bottom Ported
Series
25A-SY5000
How to Order Manifold
25A SS5Y 5
10 F 1
q
w
05 U
e r
t
y u
RoHS
C6
i
o
Series compatible
with secondary batteries
q Series
5
u SUP/EXH block assembly
y P, E port entry
SY5000
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 24 stations)
U
D
B
w Type
10
11
Side ported
Bottom ported
Internal pilot
Nil
Internal pilot, Built-in silencer
S
∗ 3/5(E) port is plugged for
the built-in silencer type.
i A, B port size (Metric)
Type 10/ Type 11/
Side ported Bottom ported
SY5000
SY5000
ø4 One-touch fitting
C4


ø6 One-touch fitting
C6


ø8 One-touch fitting
C8


Straight port, mixed sizes
CM∗


P, E port size (One-touch fittings)
ø10
ø10
Symbol
e Connector type
Straight
F: D-sub connector
(25 pins)
A, B port
LOC
K
FRE
∗ Indicate the sizes on the manifold specification sheet in the
case of “CM”.
∗ The direction of P, E port fittings is the same as for A, B port.
E
r Connector entry direction
1: Upward
2: Lateral
LOC
LOC
K
K
FRE
FRE
E
E
t Valve stations
o Mounting
Symbol
Mounting
Nil
Direct mounting
D
DIN rail mounting
DIN rail option
Standard length
Nil
With DIN bracket (Without DIN rail)
0
For 3 stations Specify a longer rail
3
than the total length
24 For 24 stations of specified stations.
Note 1) Enter the number of stations inside . (Refer to “DIN Rail
Option” above.)
Note 2) Only direct mounting is available for Type 11 (Bottom
ported).
F: D-sub connector (25 pins)
Note 1) Double wiring:
2-position single,
double, 3-position and
Note
1)
Double wiring
4-position valves can
12 12 stations
be used on all
02 2 stations Specified layout Note 2)
manifold stations.
(Available up to
Use of a 2-position
24 solenoids)
24 24 stations
single solenoid will
result in an unused control signal. If this is not desired,
order with a specified layout.
Note 2) Specified layout: Indicate the wiring specifications on
the manifold specification sheet. (Note that 2-position
double, 3-position and 4-position valves cannot be
used where single wiring has been specified.)
Note 3) This also includes the number of blanking plate
assembly.
Symbol Stations
02 2 stations
1
Note
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Series
25A-SY5000
Directional
Actuators Control
Valves
D-sub Connector
How to Order Valves (With two mounting screws)
25A SY 5 1 0 0
q w
5
e r t y
1
u i o
Related
Products
Base mounted
Series compatible
with secondary batteries
5
t Pilot valve option
SY5000
w Type of actuation
1
2
3
4
5
A
B
C
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
e Seal type
0
Rubber seal
r Back pressure check valve
(Built-in valve type)
Nil
None
H
Built-in
∗ The built-in valve type back pressure
check valve is not available for the
3-position type.
Nil
B
o Manual override
Standard (0.7 MPa)
Quick response type (0.7 MPa)
Nil:
Non-locking
push type
D:
Push-turn
locking
slotted
type
E:
Push-turn
locking
lever
type
F:
Slide locking
type
y Coil type
Nil
Standard
T
With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving
circuit type when the valve is
continuously energized for long periods
of time.
∗ Note the specified energizing time when
power saving circuit is selected.
u Rated voltage
5
6
24 VDC
12 VDC
i Light /surge voltage suppressor
and common specification
Without light /surge voltage suppressor
(Non-polar)
With surge voltage suppressor
R
(Non-polar)
With light /surge voltage suppressor
U
(Non-polar)
With surge voltage suppressor
S
(Positive common)
With light /surge voltage suppressor
Z
(Positive common)
With surge voltage suppressor
NS
(Negative common)
With light /surge voltage suppressor
NZ
(Negative common)
∗ Only “Z” and “NZ” types are available for
the product with power saving circuit.
Nil
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Protective class
class # (Mark:
)
Auto
Switches
q Series
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Plug-in Connector Connecting Base
2
Plug-in Connector Connecting Base
D-sub Connector
Type 12
Top Ported
Series
25A-SY5000
How to Order Manifold
25A SS5Y 5 12 F 1
q
RoHS
05 U
w e
r
t y
u
Series compatible
with secondary batteries
r Valve stations
q Series
5
SY5000
F: D-sub connector (25 pins) Note 1) Double wiring:
Symbol Stations
02 2 stations
w Connector type
F: D-sub connector
(25 pins)
LOC
K
FRE
E
e Connector entry direction
1: Upward
Note
2-position single,
double, 3-position
Double wiring Note 1)
and 4-position valves
12 12 stations
can be used on all
Note
2)
02 2 stations Specified layout
manifold stations.
(Available up to
Use of a 2-position
24 solenoids)
24 24 stations
single solenoid will
result in an unused
control signal. If this is not desired, order with a
specified layout.
Note 2) Specified layout: Indicate the wiring specifications on
the manifold specification sheet. (Note that 2-position
double, 3-position and 4- position valves cannot be
used where single wiring has been specified.)
Note 3) This also includes the number of blanking plate
assembly.
2: Lateral
t P, E port entry
LOC
LOC
K
K
FRE
E
FRE
E
U Note) U side (2 to 10 stations)
D Note) D side (2 to 10 stations)
B
Both sides (2 to 24 stations)
y SUP/EXH block assembly
Nil
S
Internal pilot
Internal pilot,Built-in silencer
∗ For built-in silencer type, P and
E ports are available on U and
D sides. 3/5(E) port is plugged.
The silencer exhaust port is
located on the opposite side of
P, E port entry. (Example:
When the P, E port entry is D
side, the silencer exhaust port
is U side.)
Note) y For type “S”,
supply/exhaust block
assembly with built-in
silencer, choose U or D for
P port entry.
u Mounting
Nil
D
D0
D3
Direct mounting
DIN rail mounting (With DIN rail)
DIN rail mounting (Without DIN rail)
For 3 stations Specify a longer
rail than the
D24 For 24 stations standard length.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
3
25A-SY5000
Directional
Actuators Control
Valves
Series
How to Order Valves (With two mounting screws)
q w
5
e r t y
1 C6
u i o
!0
Related
Products
25A SY 5 1 3 0
Top ported
Series compatible
with secondary batteries
t Pilot valve option
q Series
5
SY5000
w Type of actuation
1
2
3
4
5
A
B
C
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
e Seal type
0
Rubber seal
r Back pressure check valve
(Built-in valve type)
Nil
None
H
Built-in
∗ The built-in valve type back pressure
check valve is not available for the
3-position type.
Nil
B
o Manual override
Standard (0.7 MPa)
Quick response type (0.7 MPa)
Nil:
Non-locking
push type
D:
Push-turn
locking
slotted
type
E:
Push-turn
locking
lever
type
F:
Slide locking
type
y Coil type
Nil
Standard
T
With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving
circuit type when the valve is
continuously energized for long periods
of time.
∗ Note the specified energizing time when
power saving circuit is selected.
u Rated voltage
5
6
24 VDC
12 VDC
i Light/surge voltage suppressor
and common specification
Without light/surge voltage suppressor
(Non-polar)
With surge voltage suppressor
R
(Non-polar)
With light/surge voltage suppressor
U
(Non-polar)
With surge voltage suppressor
S
(Positive common)
With light/surge voltage suppressor
Z
(Positive common)
With surge voltage suppressor
NS
(Negative common)
With light/surge voltage suppressor
NZ
(Negative common)
∗ Only “Z” and “NZ” types are available for
the product with power saving circuit.
Nil
!0 A, B port size
One-touch fitting (Metric)
Symbol
A, B port
C4 ø4 One-touch fitting
C6 ø6 One-touch fitting
C8 ø8 One-touch fitting
SY5000



∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Protective class
class # (Mark:
)
4
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
D-sub Connector
Auto
Switches
Plug-in Connector Connecting Base
Plug-in Connector Connecting Base
Type 10
Side Ported
Terminal Block Box
Type 11
Bottom Ported
25A-SY5000
Series
How to Order Manifold
25A SS5Y 5
10 T
q
w
05 U
e
r t
C6
y
u
Series compatible
with secondary batteries
5
u Mounting
r P, E port entry
q Series
SY5000
U
D
B
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 20 stations)
w Type
Side ported
Bottom ported
e Valve stations
Symbol Stations
02 2 stations
10 10 stations
02 2 stations
Note
Double wiring Note 1)
Specified layout Note 2)
(Available
up to 20 solenoids)
20 20 stations
Note 1) Double wiring: 2-position single,
double, 3-position and 4-position
valves can be used on all
manifold stations.
Use of a 2-position single
solenoid will result in an unused
control signal. If this is not
desired, order with a specified
layout.
Note 2) Specified layout: Indicate the
wiring specifications with the
manifold specification sheet.
(Note that 2-position double,
3-position and 4-position valves
cannot be used where single
wiring has been specified.)
Note 3) This also includes the number of
blanking plate assembly.
t SUP/EXH block assembly
Internal pilot
Nil
Internal pilot, Built-in silencer
S
∗ 3/5(E) port is plugged for the built-in
silencer type.
∗ When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other liquids.
DIN rail option
Standard length
Nil
With DIN bracket (Without DIN rail)
0
For 3 stations Specify a longer rail
3
than the total length of
24 For 24 stations specified stations.
y A, B port size (Metric)
Symbol
Type 10/
Type 11/
Side ported Bottom ported
A, B port
ø4 One-touch fitting
C4
ø6 One-touch fitting
C6
ø8 One-touch fitting
C8
Straight port, mixed sizes
CM∗
P, E port size (One-touch fittings)
Straight
10
11
Symbol
Mounting
Direct mounting
Nil
DIN rail mounting
D
Note 1) Enter the number of stations
inside . (Refer to “DIN Rail
Option” below.)
Note 2) Only direct mounting is available
for Type 11 (Bottom ported).
SY5000




ø10
SY5000




ø10
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”.
∗ The direction of P, E port fittings is the same as for A, B port.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
5
25A-SY5000
Directional
Actuators Control
Valves
Series
How to Order Valves (With two mounting screws)
25A SY 5 1 0 0
q w
5
e r t y
1
u i o
Related
Products
Base mounted
Series compatible
with secondary batteries
t Pilot valve option
q Series
5
SY5000
Nil
B
o Manual override
Standard (0.7 MPa)
Quick response type (0.7 MPa)
w Type of actuation
1
2
3
4
5
A
B
C
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
e Seal type
0
Rubber seal
r Back pressure check valve
(Built-in valve type)
Nil
None
H
Built-in
∗ The built-in valve type back pressure
check valve is not available for the
3-position type.
Nil:
Non-locking
push type
D:
Push-turn
locking
slotted
type
E:
Push-turn
locking
lever
type
F:
Slide locking
type
y Coil type
Nil
Standard
T
With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving
circuit type when the valve is
continuously energized for long periods
of time.
∗ Note the specified energizing time when
power saving circuit is selected.
u Rated voltage
5
6
24 VDC
12 VDC
i Light/surge voltage suppressor
and common specification
Without light/surge voltage suppressor
(Non-polar)
With surge voltage suppressor
R
(Non-polar)
With light/surge voltage suppressor
U
(Non-polar)
With surge voltage suppressor
S
(Positive common)
With light/surge voltage suppressor
Z
(Positive common)
With surge voltage suppressor
NS
(Negative common)
With light/surge voltage suppressor
NZ
(Negative common)
∗ Only “Z” and “NZ” types are available for
the product with power saving circuit.
Nil
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Protective class
class # (Mark:
)
6
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Terminal Block Box
Auto
Switches
Plug-in Connector Connecting Base
Plug-in Connector Connecting Base
Terminal Block Box
Type 12
Top Ported
Series
25A-SY5000
How to Order Manifold
25A SS5Y 5 12T 05 U
q
w
e r
t
Series compatible
with secondary batteries
5
r SUP/EXH block assembly
w Valve stations
q Series
SY5000
e P, E port entry
U Note)
U side (2 to 10 stations)
D Note)
D side (2 to 10 stations)
B
Both sides (2 to 20 stations)
Note) r For type “S”, supply/exhaust
block assembly with built-in
silencer, choose U or D for P port
entry.
Symbol Stations
02 2 stations
10 10 stations
02 2 stations
Note
Double wiring Note 1)
Specified layout Note 2)
(Available up to 20 solenoids)
20 20 stations
Note 1) Double wiring: 2-position single,
double, 3-position and 4-position
valves can be used on all
manifold stations.
Use of a 2-position single
solenoid will result in an unused
control signal. If this is not
desired, order with a specified
layout.
Note 2) Specified layout: Indicate the
wiring specifications on the
manifold specification sheet.
(Note that 2-position double,
3-position and 4-position valves
cannot be used where single
wiring has been specified.)
Note 3) This also includes the number of
blanking plate assembly.
Internal pilot
Nil
Internal pilot, Built-in silencer
S
∗ For built-in silencer type, P and E ports
are available on U and D sides. 3/5(E)
port is plugged. The silencer exhaust
port is located on the opposite side of P,
E port entry.
(Example: When the P, E port entry is D
side, the silencer exhaust port is U
side.)
∗ When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other liquids.
t Mounting
Nil
Direct mounting
DIN rail mounting
D
(With DIN rail)
DIN rail mounting
D0
(Without DIN rail)
D3 For 3 stations Specify a longer rail
than the standard
D20 For 20 stations length.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
7
25A-SY5000
Directional
Actuators Control
Valves
Series
How to Order Valves (With two mounting screws)
q w
5
e r t y
1 C6
u i o
!0
Related
Products
25A SY 5 1 3 0
Top ported
Series compatible
with secondary batteries
t Pilot valve option
q Series
5
SY5000
Nil
B
o Manual override
Standard (0.7 MPa)
Quick response type (0.7 MPa)
Nil:
Non-locking
push type
D:
Push-turn
locking
slotted
type
E:
Push-turn
locking
lever
type
F:
Slide locking
type
w Type of actuation
1
2
3
4
5
A
B
C
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
e Seal type
0
Rubber seal
r Back pressure check valve
(Built-in valve type)
Nil
None
H
Built-in
∗ The built-in valve type back pressure
check valve is not available for the
3-position type.
y Coil type
Nil
Standard
T
With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving
circuit type when the valve is
continuously energized for long periods
of time.
∗ Note the specified energizing time when
power saving circuit is selected.
!0 A, B port size
u Rated voltage
5
6
24 VDC
12 VDC
i Light /surge voltage suppressor
One-touch fitting (Metric)
Symbol
A, B port
C4 ø4 One-touch fitting
C6 ø6 One-touch fitting
C8 ø8 One-touch fitting
SY5000



and common specification
Without light /surge voltage suppressor
(Non-polar)
With surge voltage suppressor
R
(Non-polar)
With light /surge voltage suppressor
U
(Non-polar)
With surge voltage suppressor
S
(Positive common)
With light /surge voltage suppressor
Z
(Positive common)
With surge voltage suppressor
NS
(Negative common)
With light /surge voltage suppressor
NZ
(Negative common)
∗ Only “Z” and “NZ” types are available for
the product with power saving circuit.
Nil
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Protective class
class # (Mark:
)
8
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Terminal Block Box
Auto
Switches
Plug-in Connector Connecting Base
Type 10
Side Ported
Type 11
Bottom Ported
Plug-in Connector Connecting Base
Lead Wire
Series
25A-SY5000
How to Order Manifold
25A SS5Y 5
10 L1 1
q
w
e
05 U
r
t
y u
RoHS
C6
i
o
Series compatible
with secondary batteries
5
e Number of cores
SY5000
(Lead wire)
L1
L2
L3
w Type
10
11
34 cores
17 cores
9 cores
r Lead wire length
Side ported
Bottom ported
1
2
3
Symbol Stations
02 2 stations
Double wiring Note 1)
16 16 stations
02 2 stations Specified layout Note 2)
(Available up to
32 solenoids)
24 24 stations
Symbol Stations
02 2 stations
u SUP/EXH block assembly
Note
i A, B port size (Metric)
Double wiring Note 1)
04 4 stations
02 2 stations Specified layout Note 2)
(Available up to
8 solenoids)
08 8 stations
(L2)
Symbol Stations
02 2 stations
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 24 stations)
Internal pilot
Nil
Internal pilot, Built-in silencer
S
∗ 3/5(E) port is plugged for the built-in silencer type.
∗ When the built-in silencer type is used, keep the exhaust port
from coming in direct contact with water or other liquids.
(L3)
Note
U
D
B
0.6 m
1.5 m
3m
t Valve stations
(L1)
y P, E port entry
Note
Double wiring Note 1)
08 8 stations
02 2 stations Specified layout Note 2)
(Available up to
16 solenoids)
16 16 stations
Note 1) Double wiring: 2-position single, double, 3-position and
4-position valves can be used on all manifold stations.
Use of a 2-position single solenoid will result in an
unused control signal. If this is not desired, order with a
specified layout.
Note 2) Specified layout: Indicate the wiring specifications on the
manifold specification sheet. (Note that 2-position double,
3-position and 4-position valves cannot be used where
single wiring has been specified.)
Note 3) This also includes the number of blanking plate
assembly.
Type 10/ Type 11/
Side ported Bottom ported
SY5000
SY5000
ø4 One-touch fitting
C4


ø6 One-touch fitting
C6


ø8 One-touch fitting
C8


Straight port, mixed sizes
CM∗


P, E port size (One-touch fittings)
ø10
ø10
Symbol
A, B port
Straight
q Series
∗ Indicate the sizes on the manifold specification sheet in the
case of “CM”.
∗ The direction of P, E port fittings is the same as for A, B port.
o Mounting
Symbol
Mounting
Direct mounting
Nil
DIN rail mounting
D
Note 1) Enter the number of stations inside . (Refer to “DIN Rail
Option” below.)
Note 2) Only direct mounting is available for Type 11 (Bottom
ported).
DIN rail option
Standard length
Nil
With DIN bracket (Without DIN rail)
0
For 3 stations Specify a longer rail than
3
the total length of specified
24 For 24 stations stations.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
9
25A-SY5000
Directional
Actuators Control
Valves
Series
How to Order Valves (With two mounting screws)
25A SY 5 1 0 0
q w
5
e r t y
1
u i o
Related
Products
Base mounted
Series compatible
with secondary batteries
q Series
5
t Pilot valve option
SY5000
Nil
B
o Manual override
Standard (0.7 MPa)
Quick response type (0.7 MPa)
w Type of actuation
1
2
3
4
5
A
B
C
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
e Seal type
0
Rubber seal
r Back pressure check valve
Nil:
Non-locking
push type
D:
Push-turn
locking
slotted
type
E:
Push-turn
locking
lever
type
F:
Slide locking
type
y Coil type
Nil
Standard
T
With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving
circuit type when the valve is
continuously energized for long periods
of time.
∗ Note the specified energizing time when
power saving circuit is selected.
u Rated voltage
5
6
24 VDC
12 VDC
(Built-in valve type)
Nil
None
H
Built-in
∗ The built-in valve type back pressure
check valve is not available for the
3-position type.
i Light /surge voltage suppressor
and common specification
Without light /surge voltage suppressor
(Non-polar)
With surge voltage suppressor
R
(Non-polar)
With light /surge voltage suppressor
U
(Non-polar)
With surge voltage suppressor
S
(Positive common)
With light /surge voltage suppressor
Z
(Positive common)
With surge voltage suppressor
NS
(Negative common)
With light /surge voltage suppressor
NZ
(Negative common)
∗ Only “Z” and “NZ” types are available for
the product with power saving circuit.
Nil
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
10
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Lead Wire
Auto
Switches
Plug-in Connector Connecting Base
Plug-in Connector Connecting Base
Lead Wire
Type 12
Top Ported
Series
25A-SY5000
How to Order Manifold
25A SS5Y 5 12 L1 1
q
w
e
RoHS
05 U
r
t y
u
Series compatible
with secondary batteries
t P, E port entry
q Series
5
SY5000
w Number of cores
(Lead wire)
L1
L2
L3
34 cores
17 cores
9 cores
e Lead wire length
1
2
3
0.6 m
1.5 m
3m
r Valve stations
(L1)
Symbol Stations
02 2 stations
(L3)
Note
Double wiring Note 1)
16 16 stations
02 2 stations Specified layout Note 2)
(Available up to
32 solenoids)
24 24 stations
Symbol Stations
02 2 stations
Note
Double wiring Note 1)
04 4 stations
02 2 stations Specified layout Note 2)
(Available up to
8 solenoids)
08 8 stations
y SUP/EXH block assembly
Internal pilot
Nil
Internal pilot, Built-in silencer
S
∗ For built-in silencer type, P and E ports are available on U and
D sides. 3/5(E) port is plugged. The silencer exhaust port is
located on the opposite side of P, E port entry. (Example: When
the P, E port entry is D side, the silencer exhaust port is U
side.)
∗ When the built-in silencer type is used, keep the exhaust port
from coming in direct contact with water or other liquids.
u Mounting
Nil
(L2)
Symbol Stations
02 2 stations
U Note)
U side (2 to 10 stations)
D Note)
D side (2 to 10 stations)
B
Both sides (2 to 24 stations)
Note) y For type “S”, supply/exhaust block assembly with built-in
silencer, choose U or D for P port entry.
Note
Double wiring Note 1)
08 8 stations
02 2 stations Specified layout Note 2)
(Available up to
16 solenoids)
16 16 stations
Direct mounting
DIN rail mounting
D
(With DIN rail)
DIN rail mounting
D0
(Without DIN rail)
D3 For 3 stations Specify a longer rail
than the standard
D24 For 24 stations length.
Note 1) Double wiring: 2-position single, double, 3-position and
4-position valves can be used on all manifold stations.
Use of a 2-position single solenoid will result in an
unused control signal. If this is not desired, order with a
specified layout.
Note 2) Specified layout: Indicate the wiring specifications on the
manifold specification sheet. (Note that 2-position double,
3-position and 4-position valves cannot be used where
single wiring has been specified.)
Note 3) This also includes the number of blanking plate
assembly.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
11
25A-SY5000
Directional
Actuators Control
Valves
Series
How to Order Valves (With two mounting screws)
q w
5
e r t y
1 C6
u i o
!0
Related
Products
25A SY 5 1 3 0
Top ported
Series compatible
with secondary batteries
t Pilot valve option
q Series
5
SY5000
w Type of actuation
1
2
3
4
5
A
B
C
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
o Manual override
Standard (0.7 MPa)
Quick response type (0.7 MPa)
Nil:
Non-locking
push type
D:
Push-turn
locking
slotted
type
E:
Push-turn
locking
lever
type
F:
Slide locking
type
y Coil type
Nil
Standard
T
With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving
circuit type when the valve is
continuously energized for long periods
of time.
∗ Note the specified energizing time when
power saving circuit is selected.
u Rated voltage
e Seal type
0
Nil
B
Rubber seal
5
6
24 VDC
12 VDC
!0 A, B port size
One-touch fitting (Metric)
r Back pressure check valve
i Light /surge voltage suppressor
Nil
None
H
Built-in
∗ The built-in valve type back pressure
check valve is not available for the
3-position type.
Without light /surge voltage suppressor
(Non-polar)
With surge voltage suppressor
R
(Non-polar)
With light /surge voltage suppressor
U
(Non-polar)
With surge voltage suppressor
S
(Positive common)
With light /surge voltage suppressor
Z
(Positive common)
With surge voltage suppressor
NS
(Negative common)
With light /surge voltage suppressor
NZ
(Negative common)
∗ Only “Z” and “NZ” types are available for
the product with power saving circuit.
(Built-in valve type)
and common specification
Nil
Symbol
A, B port
C4 ø4 One-touch fitting
C6 ø6 One-touch fitting
C8 ø8 One-touch fitting
SY5000



∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Protective class
class # (Mark:
)
12
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Lead Wire
Auto
Switches
Plug-in Connector Connecting Base
Plug-in Connector Connecting Base
Type 10
Side Ported
EX260
Type 11
Bottom Ported
Series
25A-SY5000
How to Order Manifold
25A SS5Y 5
10 S NA N 05 U
q
w
e
r
t
RoHS
C6
y u
i
o
Series compatible
with secondary batteries
t Valve stations
q Series
5
SY5000
w Type
10
11
Side ported
Bottom ported
e SI unit specifications
Number of Communication
outputs
connector
Without SI unit
0
32
QA
DeviceNet™
M12
16
QB
32
NA PROFIBUS
M12
16
DP
NB
32
DA
M12
EtherCAT ®
16
DB
For SI unit part number, refer to page 21.
DIN rail cannot be mounted without SI
unit.
Symbol
Protocol
r SI unit output polarity
Nil
Positive common
N
Negative common
Note 1) Ensure a match with the common
specifications of the value to be
used.
Note 2) Without SI unit, the symbol is nil.
In the case of the 32-output SI unit
Symbol Stations
Note
02 2 stations
Double wiring Note 1)
16 16 stations
02 2 stations
Specified layout Note 2)
(Available up to 32 solenoids)
24 24 stations
In the case of the 16-output SI unit
Symbol Stations
Note
02 2 stations
Double wiring Note 1)
08 8 stations
02 2 stations
Specified layout Note 2)
(Available up to 16 solenoids)
16 16 stations
Note 1) Double wiring: 2-position single,
double, 3-position and 4-position
valves can be used on all
manifold stations.
Use of a 2-position single
solenoid will result in an unused
control signal. If this is not
desired, order with a specified
layout.
Note 2) Specified layout: Indicate the
wiring specifications on the
manifold specification sheet.
(Note that 2-position double,
3-position and 4-position valves
cannot be used where single
wiring has been specified.)
Note 3) This also includes the number of
blanking plate assembly.
Note 4) For the model without the SI unit
(S0), note the maximum number
of solenoids of the SI unit that will
be mounted. If the layout is
specified, indicate it on the
manifold specification sheet.
y P, E port entry
U
D
B
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 24 stations)
u SUP/EXH block assembly
Nil
Internal pilot
Internal pilot, Built-in silencer
S
∗ 3/5(E) port is plugged for the built-in
silencer type.
∗ When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other liquids.
o Mounting
Symbol
Mounting
Direct mounting
Nil
DIN rail mounting
D
Note 1) Enter the number of stations
inside .
(Refer to “DIN Rail Option”
below.)
Note 2) Only direct mounting is available
for Type 11 (Bottom ported).
DIN rail option
Direct mounting
Nil
With DIN bracket (Without DIN rail)
0
For 3 stations Specify a longer rail
3
than the total length
24 For 24 stations of specified stations.
∗ When it is necessary to mount a DIN rail
without an SI unit, select D0 and order
DIN rail length separately, referring to
L3 in the dimensions.
i A, B port size (Metric)
Type 10/ Type 11/
Side ported Bottom ported
SY5000 SY5000
ø4 One-touch fitting
C4


ø6 One-touch fitting
C6


ø8 One-touch fitting
C8


Straight port, mixed sizes
CM∗


P, E port size (One-touch fittings)
ø10
ø10
A, B port
Straight
Symbol
∗ Indicate the sizes on the manifold specification sheet in the
case of “CM”.
13
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Refer to Fieldbus System (CAT.E02-25) for details on the EX260
Integrated-type (For Output) Serial Transmission System.
25A-SY5000
Directional
Actuators Control
Valves
Series
How to Order Valves (With two mounting screws)
q w
5
e r t y
1
u i o
Related
Products
25A SY 5 1 0 0
Base mounted
Series compatible
with secondary batteries
5
SY5000
w Type of actuation
1
2
3
4
5
A
B
C
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
Nil
B
Standard (0.7 MPa)
Quick response type (0.7 MPa)
Nil:
Non-locking
push type
D:
Push-turn
locking
slotted
type
E:
Push-turn
locking
lever
type
F:
Slide locking
type
y Coil type
Nil
Standard
T
With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving
circuit type when a valve is continuously
energized for long periods of time.
∗ Note the specified energizing time when
power saving circuit is selected.
u Rated voltage
e Seal type
0
o Manual override
t Pilot valve option
q Series
5
24 VDC
Rubber seal
i Light /surge voltage suppressor
r Back pressure check valve
(Built-in valve type)
Nil
None
H
Built-in
∗ The built-in valve type back pressure
check valve is not available for the
3-position type.
and common specification
With surge voltage suppressor
(Non-polar)
With light /surge voltage suppressor
U
(Non-polar)
With surge voltage suppressor
S
(Positive common)
With light /surge voltage suppressor
Z
(Positive common)
With surge voltage suppressor
NS
(Negative common)
With light /surge voltage suppressor
NZ
(Negative common)
∗ Select a valve from R, U, S or Z when
the SI unit output polarity is Nil (Positive
common). Select a valve from R, U, NS
or NZ when the SI unit output polarity is
N (Negative common).
∗ Only “Z” and “NZ” types are available for
the product with power saving circuit.
R
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Protective class
class # (Mark:
)
14
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
EX260
Auto
Switches
Plug-in Connector Connecting Base
Plug-in Connector Connecting Base
EX260
Type 12
Top Ported
Series
25A-SY5000
How to Order Manifold
RoHS
25A SS5Y 5 12S NA N 05 U
q
w
e
r
t y
u
Series compatible
with secondary batteries
q Series
5
r Valve stations
SY5000
w SI unit specifications
Number of Communication
outputs
connector
Without SI unit
0
32
QA
DeviceNet™
M12
16
QB
32
NA PROFIBUS
M12
DP
16
NB
32
DA
EtherCAT ®
M12
16
DB
For SI unit part number, refer to page 21.
DIN rail cannot be mounted without SI
unit.
Symbol
Protocol
e SI unit output polarity
Nil
Positive common (NPN)
N
Negative common (PNP)
Note 1) Ensure a match with the common
specifications of the value to be
used.
Note 2) Without SI unit, the symbol is nil.
In the case of the 32-output SI unit
Symbol Stations
Note
02 2 stations
Double wiring Note 1)
16 16 stations
02 2 stations
Specified layout Note 2)
(Available up to 32 solenoids)
24 24 stations
In the case of the 16-output SI unit
Symbol Stations
Note
02 2 stations
Double wiring Note 1)
08 8 stations
02 2 stations
Specified layout Note 2)
(Available up to 16 solenoids)
16 16 stations
Note 1) Double wiring: 2-position single,
double, 3-position and 4-position
valves can be used on all
manifold stations.
Use of a 2-position single
solenoid will result in an unused
control signal. If this is not
desired, order with a specified
layout.
Note 2) Specified layout: Indicate the
wiring specifications on the
manifold specification sheet.
(Note that 2-position double,
3-position and 4-position valves
cannot be used where single
wiring has been specified.)
Note 3) This also includes the number of
blanking plate assembly.
Note 4) For the model without the SI unit
(S0), note the maximum number
of solenoids of the SI unit that will
be mounted. If the layout is
specified, indicate it on the
manifold specification sheet.
t P, E port entry
U side (2 to 10 stations)
U Note)
D side (2 to 10 stations)
D Note)
Both sides (2 to 24 stations)
B
Note) y For type “S”, supply/exhaust
block assembly with built-in
silencer, choose U or D for P port
entry.
y SUP/EXH block assembly
Internal pilot
Nil
Internal pilot, Built-in silencer
S
∗ For built-in silencer type, P and E ports
are available on U and D sides. 3/5(E)
port is plugged. The silencer exhaust
port is located on the opposite side of P,
E port entry. (Example: When the P, E
port entry is D side, the silencer exhaust
port is U side.)
∗ When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other liquids.
u Mounting
Nil
D
D0
D3
Direct mounting
DIN rail mounting (With DIN rail)
DIN rail mounting (Without DIN rail)
For 3 stations Specify a longer
rail than the
D24 For 24 stations standard length.
∗ When it is necessary to mount a DIN rail
without an SI unit, select D0 and order
DIN rail length separately, referring to
L3 in the dimensions.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Refer to Fieldbus System (CAT.E02-25) for details on the EX260
Integrated-type (For Output) Serial Transmission System.
15
EX260
Series
25A-SY5000
Directional
Actuators Control
Valves
Plug-in Connector Connecting Base
How to Order Valves (With two mounting screws)
25A SY 5 1 3 0
e r t y
u i o
1 C6
!0
Series compatible
with secondary batteries
q Series
5
y Coil type
SY5000
w Type of actuation
1
2
3
4
5
A
B
C
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
D:
Push-turn
locking
slotted
type
u Rated voltage
E:
Push-turn
locking
lever
type
F:
Slide locking
type
5
24 VDC
and common specification
Rubber seal
r Back pressure check valve
(Built-in valve type)
Nil
None
H
Built-in
∗ The built-in valve type back pressure
check valve is not available for the
3-position type.
t Pilot valve option
Nil
B
Nil:
Non-locking
push type
i Light /surge voltage suppressor
e Seal type
0
o Manual override
Nil
Standard
T
With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving
circuit type when a valve is continuously
energized for long periods of time.
∗ Note the specified energizing time when
power saving circuit is selected.
Standard (0.7 MPa)
Quick response type (0.7 MPa)
With surge voltage suppressor
(Non-polar)
With light /surge voltage suppressor
U
(Non-polar)
With surge voltage suppressor
S
(Positive common)
With light /surge voltage suppressor
Z
(Positive common)
With surge voltage suppressor
NS
(Negative common)
With light /surge voltage suppressor
NZ
(Negative common)
∗ Select a valve from R, U, S or Z when
the SI unit output polarity is Nil (Positive
common). Select a valve from R, U, NS
or NZ when the SI unit output polarity is
N (Negative common).
∗ Only “Z” and “NZ” types are available for
the product with power saving circuit.
R
!0 A, B port size
One-touch fitting (Metric)
Symbol
A and B port
C4 ø4 One-touch fitting
C6 ø6 One-touch fitting
C8 ø8 One-touch fitting
SY5000



∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Protective class
class # (Mark:
)
16
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Related
Products
Top ported
Auto
Switches
q w
5
Plug-in Connector Connecting Base
Type 10
Side Ported
EX126
Type 11
Bottom Ported
Series
25A-SY5000
How to Order Manifold
25A SS5Y 5
10 S4 V
q
w
e
05 U
r
t y
RoHS
C6
u
i
Series compatible
with secondary batteries
q Series
w Type
10
11
Side ported
Bottom ported
e SI unit
0
Without SI unit
V
CC-Link (Positive common NPN)
∗ Only a terminal block plate is mounted
for the valve without SI unit.
For SI unit part number, refer to page 21.
r Valve stations
Symbol Stations
02 2 stations
08 8 stations
02 2 stations
i Mounting
t P, E port entry
SY5000
Note
Double wiring Note 1)
Specified layout Note 2)
(Available up to 16 solenoids)
16 16 stations
Note 1) Double wiring: 2-position single,
double, 3-position and 4-position
valves can be used on all
manifold stations.
Use of a 2-position single
solenoid will result in an unused
control signal. If this is not
desired, order with a specified
layout.
Note 2) Specified layout: Indicate the
wiring specifications with the
manifold specification sheet.
(Note that 2-position double,
3-position and 4-position valves
cannot be used where single
wiring has been specified.)
Note 3) This also includes the number of
blanking plate assembly.
U
D
B
U side (2 to 10 stations)
D side (2 to 10 stations)
Both sides (2 to 16 stations)
y SUP/EXH block assembly
Internal pilot
Nil
Internal pilot, Built-in silencer
S
∗ 3/5(E) port is plugged for the built-in
silencer type.
∗ When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other liquids.
Symbol
Mounting
Direct mounting
Nil
DIN rail mounting
D
Note 1) Enter the number of stations
inside . (Refer to “DIN Rail
Option” below.)
Note 2) Only direct mounting is available
for Type 11 (Bottom ported).
DIN rail option
Standard length
Nil
With DIN bracket (Without DIN rail)
0
For 3 stations Specify a longer rail
3
than the total length
16 For 16 stations of specified stations.
u A, B port (Metric)
Type 10/ Type 11/
Side ported Bottom ported
SY5000 SY5000
ø4 One-touch fitting
C4


ø6 One-touch fitting
C6


ø8 One-touch fitting
C8


Straight port, mixed sizes
CM∗


P, E port size (One-touch fittings)
ø10
ø10
Symbol
A, B port
Straight
5
∗ Indicate the size on the manifold specification sheet in the case
of “CM”.
∗ The direction of P, E port fittings is the same as for A, B port.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Refer to Reduced Wiring Fieldbus System (Serial Transmission)
in Electric Products (CAT.E150) for details on the EX126
Integrated-type (For Output) Serial Transmission System.
17
Series
25A-SY5000
Directional
Actuators Control
Valves
EX126
How to Order Valves (With two mounting screws)
25A SY 5 1 0 0
q w
5
e r t y
1
u i o
Related
Products
Base mounted
Series compatible
with secondary batteries
t Pilot valve option
5
SY5000
w Type of actuation
1
2
3
4
5
A
B
C
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
e Seal type
0
Rubber seal
r Back pressure check valve
(Built-in valve type)
Nil
None
H
Built-in
∗ The built-in valve type back pressure
check valve is not available for the
3-position type.
Nil
B
o Manual override
Standard (0.7 MPa)
Quick response type (0.7 MPa)
Nil:
Non-locking
push type
D:
Push-turn
locking
slotted
type
E:
Push-turn
locking
lever
type
F:
Slide locking
type
y Coil type
Nil
Standard
T
With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving
circuit type when the valve is
continuously energized for long periods
of time.
∗ Note the specified energizing time when
power saving circuit is selected.
u Rated voltage
5
24 VDC
i Light /surge voltage suppressor
and common specification
With surge voltage suppressor
(Non-polar)
With light /surge voltage suppressor
U
(Non-polar)
With surge voltage suppressor
S
(Positive common)
With light /surge voltage suppressor
Z
(Positive common)
∗ Only “Z” type is available for the product
with power saving circuit.
R
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Auto
Switches
q Series
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Plug-in Connector Connecting Base
18
Plug-in Connector Connecting Base
EX126
Type 12
Top Ported
Series
25A-SY5000
How to Order Manifold
25A SS5Y 5 12S4 V
q
w
RoHS
05 U
e
r t
y
Series compatible
with secondary batteries
e Valve stations
q Series
5
SY5000
w SI unit
0
Without SI unit
V
CC-Link (Positive common NPN)
∗ Only a terminal block plate is mounted
for the valve without SI unit.
For SI unit part number, refer to page 21.
Symbol Stations
02 2 stations
08 8 stations
02 2 stations
r P, E port entry
Note
Double wiring Note 1)
Specified layout Note 2)
(Available up to 16 solenoids)
16 16 stations
Note 1) Double wiring: 2-position single,
double, 3- position and 4-position
valves can be used on all
manifold stations.
Use of a 2-position single
solenoid will result in an unused
control signal. If this is not
desired, order with a specified
layout.
Note 2) Specified layout: Indicate the
wiring specifications on the
manifold specification sheet.
(Note that 2-position double,
3-position and 4-position valves
cannot be used where single
wiring has been specified.)
Note 3) This also includes the number of
blanking plate assembly.
U Note)
U side (2 to 10 stations)
D Note)
D side (2 to 10 stations)
B
Both sides (2 to 16 stations)
Note) t For type “S”, supply/exhaust
block assembly with built-in
silencer, choose U or D for P port
entry.
t SUP/EXH block assembly
Internal pilot
Nil
Internal pilot, Built-in silencer
S
∗ For built-in silencer type, P and E ports
are available on U and D sides. 3/5(E)
port is plugged. The silencer exhaust
port is located on the opposite side of P,
E port entry. (Example: When the P, E
port entry is D side, the silencer exhaust
port is U side.)
∗ When the built-in silencer type is used,
keep the exhaust port from coming in
direct contact with water or other liquids.
y Mounting
Nil
D
D0
D3
Direct mounting
DIN rail mounting (With DIN rail)
DIN rail mounting (Without DIN rail)
For 3 stations Specify a longer
rail than the
D16 For 16 stations standard length.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Refer to Reduced Wiring Fieldbus System (Serial Transmission)
in Electric Products (CAT.E150) for details on the EX126
Integrated-type (For Output) Serial Transmission System.
19
25A-SY5000
Directional
Actuators Control
Valves
Series
How to Order Valves (With two mounting screws)
q w
5
e r t y
1 C6
u i o
!0
Related
Products
25A SY 5 1 3 0
Top ported
Series compatible
with secondary batteries
q Series
t Pilot valve option
5
SY5000
w Type of actuation
1
2
3
4
5
A
B
C
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual 3-port valve (N.C./N.C.)
4-position dual 3-port valve (N.O./N.O.)
4-position dual 3-port valve (N.C./N.O.)
e Seal type
0
Rubber seal
r Back pressure check valve
(Built-in valve type)
Nil
None
H
Built-in
∗ The built-in valve type back pressure
check valve is not available for the
3-position type.
Nil
B
o Manual override
Standard (0.7 MPa)
Quick response type (0.7 MPa)
Nil:
Non-locking
push type
D:
Push-turn
locking
slotted
type
E:
Push-turn
locking
lever
type
F:
Slide locking
type
y Coil type
Nil
Standard
T
With power saving circuit (Continuous duty type)
∗ Be sure to select the power saving
circuit type when the valve is
continuously energized for long periods
of time.
∗ Note the specified energizing time when
power saving circuit is selected.
u Rated voltage
5
24 VDC
i Light /surge voltage suppressor
and common specification
With surge voltage suppressor
(Non-polar)
With light /surge voltage suppressor
U
(Non-polar)
With surge voltage suppressor
S
(Positive common)
With light /surge voltage suppressor
Z
(Positive common)
∗ Only “Z” types are available for models
with a power saving circuit.
R
!0 A, B port size
One-touch fitting (Metric)
Symbol
A, B port
C4 ø4 One-touch fitting
C6 ø6 One-touch fitting
C8 ø8 One-touch fitting
SY5000



∗ Specifications and dimensions
for the 25A-series are the
same as standard products.
Caution
Tightening torque for mounting screw
M3: 0.8 N·m
Manifold Options
Blanking plate assembly
(With two mounting screws)
Used when valve additions are expected or for
maintenance. A structure is in place on the blanking plate
to prevent the mounting screws from sliding.
Mounting screw
How to Order Blanking Plate Assembly
25A SY 5 0M 26
1 A
Series
5
SY5000
Base type
1
25A-SY50M-26-1A
For plug-in connector connecting base
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
20
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
EX126
Auto
Switches
Plug-in Connector Connecting Base
Series
25A-SY5000
SI Unit Part No.
Part no.
25A-SS5Y5
EX260-SPR1-X117
EX260-SPR2-X117
EX260-SPR3-X117
EX260-SPR4-X117
EX260-SDN1-X117
EX260-SDN2-X117
EX260-SDN3-X117
EX260-SDN4-X117
EX260-SEC1-X117
EX260-SEC2-X117
EX260-SEC3-X117
EX260-SEC4-X117
EX126D-SMJ1-X220
Description
EX260 SI unit
EX126 SI unit
Note
PROFIBUS M12 connector, 32 outputs (Negative common) (PNP)
PROFIBUS M12 connector, 32 outputs (Positive common) (NPN)
PROFIBUS M12 connector, 16 outputs (Negative common) (PNP)
PROFIBUS M12 connector, 16 outputs (Positive common) (NPN)
DeviceNet™ M12 connector, 32 outputs (Negative common) (PNP)
DeviceNet™ M12 connector, 32 outputs (Positive common) (NPN)
DeviceNet™ M12 connector, 16 outputs (Negative common) (PNP)
DeviceNet™ M12 connector, 16 outputs (Positive common) (NPN)
EtherCAT® M12 connector, 32 outputs (Negative common) (PNP)
EtherCAT® M12 connector, 32 outputs (Positive common) (NPN)
EtherCAT® M12 connector, 16 outputs (Negative common) (PNP)
EtherCAT® M12 connector, 16 outputs (Positive common) (NPN)
CC-Link (Terminal block, 16 outputs, Positive common (NPN))
Valve Mounting Screw Part No.
Description
Round head combination screw
Part no.
25A-SS5Y5
SY5000-223-1A
Note
Part numbers shown on the left are for 10 valves. (20 pcs.)
One-touch Fittings Part No.
SY5000
Port size
A, B port
Metric size
P, E port
Metric size
21
ø4 One-touch fitting (Straight type)
ø6 One-touch fitting (Straight type)
ø8 One-touch fitting (Straight type)
ø10 One-touch fitting (Straight type)
90-VVQ1000-51A-C4
90-VVQ1000-51A-C6
90-VVQ1000-51A-C8
90-VVQ2000-51A-C10
Series 25A-SY5000/7000
How to Order
Series compatible
with secondary
batteries
A, B port size
Series
5
7
Coil specifications
SY5000
SY7000
Standard
With power saving circuit
T
(24, 12 VDC only)
∗ Power saving circuit is not
available in the case of D,
Y or W type.
Nil
Type of actuation
1
2
3
4
5
2 position single
2 position double
3 position
closed center
3 position
exhaust center
3 position
pressure center
For DC
5 24 VDC
6 12 VDC
V 6 VDC
S 5 VDC
R 3 VDC
Manual override
Electrical entry
G: With lead wire L: With lead wire M: With lead wire MN: Without D,Y: With connector
(Length 300 mm) (Length 300 mm) (Length 300 mm)
lead wire



H: With lead wire LN: Without LO: Without
(Length 600 mm)
lead wire
connector
D: Push-turn locking E: Push-turn locking
slotted type
lever type
Rated voltage
12 VDC/
24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24,
100, 110, 200, 220 VAC
Grommet L plug connector M plug connector DIN terminal

Thread piping
Symbol
Port size
Applicable series
Rc 1 8
SY5000
01
SY7000
Rc 1 4
02
One-touch fitting (Metric size)
Symbol
Port size
Applicable series
C4 One-touch fitting for ø4
SY5000
C6 One-touch fitting for ø6
C8 One-touch fitting for ø8
C8 One-touch fitting for ø8
SY7000
C10 One-touch fitting for ø10
Nil: Non-locking
push type
For AC ( 50 60 Hz)
100 VAC
1
200 VAC
2
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
∗ DC specifications of type
D and Y is only available
with 12 and 24 VDC.

01
Related
Products
L
MO: Without
connector

∗ LN, MN type: with 2 sockets.
∗ “Y” type is a DIN terminal conforming to
EN-175301-803C (former DIN43650C).
∗ Refer to the standard products for the lead wire length
of L and M plug connectors and the connector
assembly with cover for L and M plug connector.
Light /surge voltage suppressor
Electrical entry for G, H, L, M
Electrical entry for D, Y
Without light /surge
Without light /surge
Nil
Nil
voltage suppressor
voltage suppressor
With surge
With surge
S
S
voltage suppressor
voltage suppressor
With light /surge
With light /surge
Z
Z
voltage suppressor
voltage suppressor
With surge voltage suppressor ∗ For AC voltage valves there
R
(Non-polar type)
is no “S” option. It is already
With light /surge voltage suppressor
built-in to the rectifier circuit.
U
(Non-polar type)
∗ For AC voltage valves there is no
“S” option. It is already built-in to the
rectifier circuit.
∗ For “R” and “U”, DC voltage is only
available.
∗ Power saving circuit is only
available in the "Z" type.
Note) When placing an order for body ported solenoid valve as a single
unit, mounting screw for manifold and gasket are not attached.
Order them separately, if necessary.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
22
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
5
Auto
Switches
SY 5 1 20
25A
Directional
Actuators Control
Valves
5 Port Solenoid Valve
Body Ported/Single Unit
5 Port Solenoid Valve
Base Mounted/Single Unit
Series 25A-SY5000/7000
How to Order
25A SY 5 2 40
5
L
Port size
Symbol
Nil
Series compatible
with secondary
batteries
02
03
Port size
Applicable series
Without sub-plate
Rc 1 4
SY5000
With sub-plate
SY7000
Rc 3 8
SY7000
With sub-plate
SY9000
Series
5
7
SY5000
SY7000
Manual override
Nil: Non-locking D: Push-turn locking E: Push-turn locking
push type
slotted type
lever type
Type of actuation
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
1
2
3
4
5
Light /surge voltage suppressor
Pilot type
Nil
R
Internal pilot
External pilot
Coil specifications
Nil
T
Standard
With power saving circuit
(24, 12 VDC only)
∗ Power saving circuit is not available in
the case of D or Y type.
Rated voltage
5
6
V
S
R
For DC
24 VDC
12 VDC
6 VDC
6 VDC
3 VDC
For AC ( 50 60 Hz)
100 VAC
1
200 VAC
2
110 VAC [115 VAC]
3
220 VAC [230 VAC]
4
∗ DC specifications of type D and Y is
only available with 12 and 24 VDC.
Electrical entry for G, H, L, M
Electrical entry for D, Y
Nil Without light /surge voltage suppressor
Nil Without light /surge voltage suppressor
With surge voltage suppressor
S
S With surge voltage suppressor (Non-polar type)
Z With light /surge voltage suppressor
Z With light/surge voltage suppressor (Non-polar type)
R With surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there is no “S”
U With light/surge voltage suppressor (Non-polar type)
option. It is already built-in to the
rectifier circuit.
∗ For AC voltage valves there is no “S”
option. It is already built-in to the
rectifier circuit.
∗ For “R” and “U”, DC voltage is only
available.
∗ Power saving circuit is only available in
the "Z" type.
Electrical entry
24, 12, 6, 5, 3 VDC / 100, 110, 200, 220 VAC
Grommet L plug connector
M plug connector
24, 12 VDC /
100, 110, 200, 220 VAC
DIN terminal
G: With lead wire L: With lead wire M: With lead wire MN: Without D,Y: With connector
(Length 300 mm) (Length 300 mm) (Length 300 mm)
lead wire
+-
+-
–+
-+
H: With lead wire LN: Without
(Length 600 mm)
lead wire
–+
LO: Without
MO: Without
connector
connector
-+
∗ LN, MN type: with 2 sockets.
∗ “Y” type is a DIN terminal conforming to EN-175301-803C (former DIN43650C).
∗ Refer to the standard products for the lead wire length of L and M plug connectors and the
connector assembly with cover for L and M plug connector.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
23
20 Series 25A-SY5000/7000
How to Order Manifold
20
05
Related
Products
Series
compatible
with secondary
batteries
Manifold series
5
7
SY5000
SY7000
Stations
02
2 stations
…
20 20 stations
∗ This also includes the
number of blanking
plate assemblies.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
25A SS5Y 5
Auto
Switches
Type
Directional
Actuators Control
Valves
5 Port Solenoid Valve
Body Ported Manifold
Bar Stock Type/Individual Wiring
24
Series
25A-SY5000/7000
How to Order Valve
25A
SY 5 1 20
5
L
01
Series
compatible
with
secondary
batteries
A, B port size
Thread piping
Symbol
Port size
Rc 1 8
01
Rc 1 4
02
One-touch fitting (Metric size)
Symbol
Port size
Applicable series
C4 One-touch fitting for ø4
C6 One-touch fitting for ø6
SY5000
C8 One-touch fitting for ø8
C8 One-touch fitting for ø8
SY7000
C10 One-touch fitting for ø10
Series
5
7
SY5000
SY7000
Type of actuation
1
2
3
4
5
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
Manual override
Nil
D
E
Coil specifications
Nil
T
Standard
With power saving circuit (24 VDC, 12 VDC only)
∗ Power saving circuit is not available in the case of D or Y
type.
Rated voltage
For DC
5
6
V
S
R
24 VDC
12 VDC
6 VDC
5 VDC
3 VDC
Applicable series
SY5000
SY7000
For AC ( 50 60 Hz)
1
100 VAC
2
200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
∗ DC specifications of type D and Y is only available
with 12 and 24 VDC.
Non-locking push type
Push-turn locking slotted type
Push-turn locking lever type
Light /surge voltage suppressor
Electrical entry for G, H, L, M
Without light /surge voltage suppressor
Nil
With surge voltage suppressor
S
With light /surge voltage suppressor
Z
With surge voltage suppressor (Non-polar type)
R
U With light /surge voltage suppressor (Non-polar type)
∗ For AC voltage valves there is no “S” option. It is already
built-in to the rectifier circuit.
∗ For “R” and “U”, DC voltage is only available.
∗ Power saving circuit is only available in the “Z” type.
Electrical entry for D, Y
Without light /surge voltage suppressor
Nil
With surge voltage suppressor (Non-polar type)
S
Z With light /surge voltage suppressor (Non-polar type)
∗ For AC voltage valves there is no “S” option. It is already
built-in to the rectifier circuit.
Electrical entry
24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC
Grommet
L plug connector
M plug connector
G: With lead wire
L: With lead wire
M: With lead wire
(Length 300 mm)
(Length 300 mm)
(Length 300 mm)
H: With lead wire
LN: Without lead wire MN: Without lead wire
(Length 600 mm) LO: Without connector MO: Without connector
24, 12 VDC/
100, 110, 200,
220 VAC
DIN terminal
D: With connector
Y: With connector
∗ LN, MN type: with 2 sockets.
∗ “Y” type is a DIN terminal conforming to EN-175301-803C (former DIN43650C).
∗ Refer to the standard products for the lead wire length of L and M plug connectors and the
connector assembly with cover for L and M plug connector.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
25
How to Order Manifold
25A
SS5Y 5
41 05
Related
Products
Type 41/Compact style
C8
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Series
compatible
with secondary
batteries
Manifold series
5
SY5000
Stations
02
2 stations
20 20 stations
∗ This also includes the
number of blanking
plate assemblies.
A, B port size
Thread piping
Symbol
Port size
01
Rc 1 8
Applicable series
SY5000
One-touch fitting (Metric size)
One-touch fitting (Inch size)
Symbol
Port size
Applicable series Symbol
Port size
Applicable series
C6 One-touch fitting for ø6
N7 One-touch fitting for ø 1 4"
SY5000
SY5000
C8 One-touch fitting for ø8
N9 One-touch fitting for ø 5 16"
Type 42/External pilot capable
25A SS5Y 5
42 05
C8
Series
compatible
with secondary
batteries
Manifold series
5
7
SY5000
SY7000
A, B port size
Stations
02
2 stations
20 20 stations
∗ This also includes the
number of blanking
plate assemblies.
Directional
Actuators Control
Valves
Type
41
42 Series 25A-SY5000/7000
Thread piping
Port size
Symbol
Rc 1 4
02
Rc 1 4
02
Applicable series
SY5000
SY7000
One-touch fitting (Inch size)
One-touch fitting (Metric size)
Symbol
Port size
Applicable series Symbol
Port size
Applicable series
N7 One-touch fitting for ø 1 4"
C6 One-touch fitting for ø6
SY5000
SY5000
N9 One-touch fitting for ø 5 16"
C8 One-touch fitting for ø8
3
"
N11 One-touch fitting for ø 8
C10 One-touch fitting for ø10 SY7000
SY7000
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
26
Auto
Switches
Type
5 Port Solenoid Valve
Base Mounted Manifold
Bar Stock Type/Individual Wiring
Series
25A-SY5000/7000
How to Order Valve
SY 5 2 40
25A
5
L
Series
compatible
with
secondary
batteries
Series
5
7
SY5000
SY7000
Type of actuation
1
2
3
4
5
Manual override
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
Nil
D
E
Light /surge voltage suppressor
Pilot type
Nil
R
Electrical entry for G, H, L, M
Without light /surge voltage suppressor
Nil
With surge voltage suppressor
S
With light /surge voltage suppressor
Z
With surge voltage suppressor (Non-polar type)
R
U With light /surge voltage suppressor (Non-polar type)
Internal pilot
External pilot
Coil specifications
Nil
T
Non-locking push type
Push-turn locking slotted type
Push-turn locking lever type
Standard
With power saving circuit
(24 VDC, 12 VDC only)
∗ For AC voltage valves there is no “S” option. It is already
built-in to the rectifier circuit.
∗ For “R” and “U”, DC voltage is only available.
∗ Power saving circuit is only available in the “Z” type.
∗ Power saving circuit is not
available in the case of D or Y
type.
Electrical entry for D, Y
Without light /surge voltage suppressor
Nil
With surge voltage suppressor (Non-polar type)
S
Z With light /surge voltage suppressor (Non-polar type)
Rated voltage
For DC
24 VDC
5
12 VDC
6
6 VDC
V
5 VDC
S
3 VDC
R
For AC ( 50 60 Hz)
100 VAC
1
200 VAC
2
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
∗ For AC voltage valves there is no “S” option. It is already
built-in to the rectifier circuit.
∗ DC specifications of Type
D and Y is only available
with 12 and 24 VDC.
Electrical entry
24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC
Grommet
L plug connector
M plug connector
G: With lead wire
L: With lead wire
M: With lead wire
(Length 300 mm)
(Length 300 mm)
(Length 300 mm)
H: With lead wire
LN: Without lead wire MN: Without lead wire
(Length 600 mm) LO: Without connector MO: Without connector
24, 12 VDC/
100, 110, 200,
220 VAC
DIN terminal
D: With connector
Y: With connector
∗ LN, MN type: with 2 sockets.
∗ “Y” type is a DIN terminal conforming to EN-175301-803C (former DIN43650C).
∗ Refer to the standard products for the lead wire length of L and M plug connectors and the
connector assembly with cover for L and M plug connector.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
27
5 Port Solenoid Valve
Series
25A-SY5000/7000
25A-SY5000
Port size
Cylinder
port
Metric size
ø4 One-touch fitting (Straight type)
ø6 One-touch fitting (Straight type)
ø8 One-touch fitting (Straight type)
ø10 One-touch fitting (Straight type)
Directional
Actuators Control
Valves
One-touch Fittings Part No. for Body Ported
25A-SY7000
90-VVQ1000-51A-C4
90-VVQ1000-51A-C6
90-VVQ1000-51A-C8
90-VVQ2000-51A-C8
90-VVQ2000-51A-C10
Gasket Assembly Part No.
25A-SY5000
Manifold type
Body ported
Base mounted
Type 20
Type 41/42
25A-SY7000
SY7000-GS-3
SY7000-GS-4
SY5000-GS-3
SY5000-GS-4
Related
Products
Valve model
∗ The gasket assembly includes 10 sets of a gasket and mounting screws.
Blanking plate assembly
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Manifold Options
How to Order
(Mounting screw: 2 pcs., with gasket)
It is used by attaching on the manifold block for being prepared for
removing a valve for maintenance reasons or planning to mount a
spare valve, etc.
25A SY 5 000 26 1A
Series
5
7
Tightening torque: 0.8 N·m
Round head combination screw
25A-SY5000
25A-SY7000
Blanking plate
Manifold gasket
Dimensions
Manifold type/For type 20
Manifold type/For type 41/42
W1
EB
B
B
EA
B
W
B
−+
−+
EB
A
H2
A
H1
−+
H1
−+
P
W2
EA
A
A
A
A
A
A
P
B
H2
Dimensions
Series
25A-SY5000
25A-SY7000
(mm)
Manifold
type
W1
W2
H1
H2
Type 20
33.3
69.6
44.5
15.2
Type 20
39.4
76.4
41.1
18.3
B
Dimensions
Series
25A-SY5000
25A-SY7000
(mm)
Manifold
type
W
Type 41
106.4
51
21.7
Type 42
107.6
56
26.7
Type 42
118.1
55.6
32.8
H1
H2
Auto
Switches
B
28 A
Plug-in Unit/Base Mounted
F Kit (D-sub connector kit)
25A-VQ2000
Series
Note) For CE compliant
models, DC-type only.
How to Order Manifold
25A VV5Q 2 1
08 C6
F
VQ2000
Stations
Plug-in unit
…
02 2 stations
…
24 24 stations
Cylinder port
Port size
Symbol
With ø4 One-touch fitting
C4
With ø6 One-touch fitting
C6
With ø8 One-touch fitting
C8
Connector entry
direction
Note 1) When two or more symbols are specified, indicate them alphabetically.
Example) -BRS
Note 2) Models with a suffix “-B” have check valves for prevention of back
pressure at all manifold stations. When a back pressure check valve is
desired, and is to be installed only in certain manifold stations, specify
the mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the
manifold number of stations.
Note 4) Specify the wiring specifications by means of the manifold
specification sheet.
Note 5) Indicate “R” for the valve with external pilot.
Top entry
Side entry
U
S
Cable (Length)
Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)
0
1
2
3
Note) For CE compliant
models, DC-type only.
How to Order Valves
25A VQ 2 1 0 1
5
CE compliant
Nil
Q
Series
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C./N.C.)
4-position dual port (N.O./N.O.)
4-position dual port (N.C./N.O.)
1
Manual override
Rubber seal
Symbol Specifications
B
N
R
DC
(0.4 W)

High-speed (0.95 W)
response type

Negative

common
AC
Standard
External
pilot

Use the standard (DC) specification when
continuously energizing for long periods of time.
29
Nil
E
—


Non-locking push type (Tool required)
Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)
Light/surge voltage suppressor
—
Note) When two or more symbols are
specified, indicate them
alphabetically.
Caution
Nil
B
C
D
Function
Nil
—
CE compliant
Note) For CE compliant models,
DC-type only.
Seal
VQ2000
Type of actuation
1
2
3
4
5
A
B
C
[Option]
1
Series compatible with
secondary batteries
2
—
CE compliant
Note) For CE compliant models,
DC-type only.
Option
Manifold
1
Nil
Q
Symbol
Option
Nil
None
2
200/220 VAC models
B Note 2)
With back pressure check valve
D
DIN rail mounting
D0
With DIN rail bracket (Without DIN rail)
D Note 3)
DIN rail length specified (: Stations 02 to 24)
K Note 4) Special wiring specifications (Except double wiring)
N
With name plate
R Note 5)
External pilot
S
Direct EXH outlet with built-in silencer
Series
2
CE compliant
U 1
Series compatible with
secondary batteries
[Option]
Yes
None
Coil voltage
1
2
3
4
5
6
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
CE compliant
—
—
—
—


∗ Specifications and dimensions for the 25A-series are the
same as standard products.
25A-VQ2000
08 C6
T0
CE compliant
Series compatible with
secondary batteries
Nil
Q
Series
2
Symbol
Nil
B Note 2)
D
Manifold
1
Plug-in unit
Stations
…
02
2 stations
…
20
20 stations
D0
D Note 5)
K Note 5)
Cylinder port
Symbol
Port size
C4
With ø4 One-touch fitting
C6
With ø6 One-touch fitting
C8
With ø8 One-touch fitting
N
R Note 6)
S
W
—
CE compliant
Note) For CE compliant models, DC-type only.
Option
VQ2000
Option
None
With back pressure check valve
DIN rail mounting
With DIN rail bracket
(Without DIN rail)
DIN rail length specified
(: Stations 02 to 24)
Special wiring spec.
(Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
Enclosure: Dust-tight,
Water-jets-proof (IP65)
25A VQ 2 1 0 1
2
Note 1) When two or more symbols are specified,
indicate them alphabetically.
Example) -BRS
Note 2) Models with a suffix “-B” have check valves
for prevention of back pressure at all
manifold stations. When a back pressure
check valve is desired, and is to be
installed only in certain manifold stations,
specify the mounting position by means of
the manifold specification sheet.
Note 3) The number of stations that may be
displayed is longer than the manifold
number of stations.
Note 4) Specify the mounting position by means of
the manifold specification sheet.
Note 5) Specify the wiring specifications by means
of the manifold specification sheet.
Note 6) Indicate “R” for the valve with external pilot.
Note) For CE compliant
models, DC-type only.
How to Order Valves
Series compatible with
secondary batteries
CE compliant
Series
Nil
Q
VQ2000
Enclosure
Nil
W
Rubber seal
Function
Symbol Specifications
B
N
Caution
Use the standard (DC)
specification when
continuously energizing for
long periods of time.
R
Dustproof
Dust-tight / Water-jets-proof type
(IP65)
Manual override
Nil
B
C
D
Seal
1
—
CE compliant
Note) For CE compliant
models, DC-type only.
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C./N.C.)
4-position dual port (N.O./N.O.)
4-position dual port (N.C./N.O.)
Nil
[Option]
1
5
Type of actuation
1
2
3
4
5
A
B
C
Related
Products
25A VV5Q 2 1
[Option]
DC
(0.4 W)
Standard

High-speed (0.95 W)
response type

Negative

common
External

pilot
AC

—
—

Note) When two or more symbols are
specified, indicate them alphabetically.
Combination of [B] and [K] is not
possible.
Non-locking push type (Tool required)
Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)
Light/surge voltage suppressor
Nil
E
Yes
None
Coil voltage
1 100 VAC (50/60 Hz)
3 110 VAC (50/60 Hz)
5
24 VDC
6
12 VDC
CE compliant
—
—


∗ Specifications and dimensions for the 25A-series
are the same as standard products.
30
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Note) For CE compliant
models, DC-type only.
How to Order Manifold
Auto
Switches
Series
Directional
Actuators Control
Valves
Plug-in Unit/Base Mounted
T Kit (Terminal block box kit)
Plug-in Unit/Base Mounted
L Kit (Lead wire)
Series
25A-VQ2000
Note) For CE compliant
models, DC-type only.
How to Order Manifold
25A VV5Q 2 1
06 C6
0 Cable length 0.6 m
1 Cable length 1.5 m
2 Cable length 3 m
Series
Manifold
1 station
…
08
8 stations
Note) For CE compliant models,
DC-type only.
Symbol
Option
Nil
None
2
200/220 VAC models
B Note 2)
With back pressure check valve
D
DIN rail mounting
D0
With DIN rail bracket (Without DIN rail)
DIN rail length specified
D Note 3)
(: Stations 02 to 08)
N
With name plate
R Note 4)
External pilot
S
Direct EXH outlet with built-in silencer
Enclosure: Dust-tight,
W
Water-jets-proof (IP65)
Stations
01
Cylinder port
Symbol
Port size
C4
With ø4 One-touch fitting
C6
With ø6 One-touch fitting
C8
With ø8 One-touch fitting
25A VQ 2 1 0 1
Note 1) When two or more symbols are
specified, indicate them alphabetically.
Example) -BRS
Note 2) Models with a suffix “-B” have check
valves for prevention of back pressure
at all manifold stations. When a back
pressure check valve is desired, and is
to be installed only in certain manifold
stations, specify the mounting position
by means of the manifold specification
sheet.
Note 3) The number of stations that may be
displayed is longer than the manifold a
number of stations.
Note 4) Indicate “R” for the valve with external
pilot.
Note) For CE compliant
models, DC-type only.
How to Order Valves
Series compatible with
secondary batteries
—
CE compliant
Option
Plug-in unit
…
Nil
Q
Cable (Length)
VQ2000
1
1
CE compliant
Series compatible with
secondary batteries
2
L
CE compliant
Series
2
Nil
Q
VQ2000
Enclosure
Nil
W
Rubber seal
Function
Symbol Specifications
B
N
R
DC
(0.4 W)
Standard

High-speed (0.95 W)
response type

Negative

common
External

pilot
Nil
E

Yes
None
—
Coil voltage
—
1
2
3
4
5
6

Non-locking push type (Tool required)
Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)
Light/surge voltage suppressor
AC
Note) When two or more symbols are
specified, indicate them alphabetically.
31
Dustproof
Dust-tight / Water-jets-proof type
(IP65)
Manual override
Nil
B
C
D
Seal
1
—
CE compliant
Note) For CE compliant
models, DC-type only.
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C./N.C.)
4-position dual port (N.O./N.O.)
4-position dual port (N.C./N.O.)
Nil
[Option]
1
5
Type of actuation
1
2
3
4
5
A
B
C
[Option]
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
CE compliant
—
—
—
—


∗ Specifications and dimensions for the 25A-series are the same as standard products.
25A-VQ2000
How to Order Manifold
08 C6
SV
CE compliant
Series compatible with
secondary batteries
Nil
Q
VQ2000
Manifold
1
Option
Plug-in unit
Symbol
Option
Nil
None
B Note 2) With back pressure check valve
D
DIN rail mounting
DIN rail length specified
D Note 3)
(: Stations 02 to 16)
Special wiring specifications
K Note 4)
(Except double wiring)
N
With name plate
R Note 5)
With external pilot
Direct EXH outlet
S
with built-in silencer
Enclosure: Dust-tight,
W Note 6)
Water-jets-proof (IP65)
Stations
02
2 stations
…
16 Note)
16 stations
…
—
CE compliant
∗ Refer to “SI Unit Part No.” when ordering
the CE-compliant SI unit.
Series
2
Note) Max. 16 stations.
(Specify a model with
9 to 16 stations by
means of the manifold
specification sheet.)
Cylinder port
Port size
Symbol
C4 With ø4 One-touch fitting
C6 With ø6 One-touch fitting
C8 With ø8 One-touch fitting
Note 1) When two or more symbols are specified,
indicate them alphabetically.
Example) -BRS.
Note 2) Models with a suffix “-B” have check valves for
prevention of back pressure at all manifold
stations. When a back pressure check valve is
desired, and is to be installed only in certain
manifold stations, specify the mounting position
by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is
longer than the manifold number of stations.
Note 4) Specify the wiring specifications by means of
the manifold specification sheet.
Note 5) Indicate “R” for the valve with external pilot.
Note 6) Refer to “Dimensions” of the standard products
for SI unit and valve, in case of W (Dust-tight,
Water-jet-proof).
SI Unit Part No.
SI Unit Part No. (With option W)
Symbol Protocol
SI unit part no.
Q
DeviceNet™ EX120-SDN1-X220
V
EX120-SMJ1-X220
CC-Link
Symbol Protocol
SI unit part no.
Q
DeviceNet™ EX124D-SDN1-X220
V
EX124D-SMJ1-X220
CC-Link
SI unit specifications
Symbol
Stations
Protocol
—
0
Without SI unit
Q
DeviceNet™ System Max.16
V
stations
CC-Link
How to Order Valves
25A VQ 2 1 0 1
5
CE compliant
Nil
Q
VQ2000
Series compatible with
secondary batteries
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C./N.C.)
4-position dual port (N.O./N.O.)
4-position dual port (N.C./N.O.)
Seal
1
—
CE compliant
Manual override
Nil
B
C
D
Type of actuation
1
2
3
4
5
A
B
C
[Option]
1
Series
2
Related
Products
25A VV5Q 2 1
[Option]
Rubber seal
Non-locking push type (Tool required)
Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)
Enclosure
Nil
W
Dustproof
Dust-tight / Water-jets-proof type
(IP65)
Coil voltage
Function
24 VDC;
With indicator light /
5
DC
surge voltage suppressor
(0.4 W)
Standard

High-speed (0.95 W)
response type

Negative
Note 1) External pilot and negative common specifications

common
are the same as standard products.
External
Note 2) When two or more symbols are specified, indicate

pilot
them alphabetically.
Symbol Specifications
Nil
B
N Note 1)
R Note 1)
∗ Specifications and dimensions for the 25A-series are the same as standard products.
32
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Note) Refer to “SI Unit Part
No.” when ordering the
CE-compliant SI unit.
Auto
Switches
Series
Directional
Actuators Control
Valves
Plug-in Unit/Base Mounted
S Kit (Serial transmission)
Sub-plate Single Unit
25A-VQ2000
Series
Note) For CE compliant models,
[Option]
DC-type only.
How to Order
In the case of
Valve + Sub-plate
25A VQ2 1 0 1
5 W 1
02
CE compliant
Series compatible with
secondary batteries
Nil
Q
Entry is the same as
standard products.
Note) For CE compliant models,
DC-type only.
Enclosure
Nil
W Note 1)
Thread type
Dustproof
Dust-tight/Water-jets-proof type
(IP65)
Nil
N
T
F
Note 1) Valves are IP65 specifications.
Note 2) When the valve is a standard
(dust-protected) specification, it is not
compatible with 200 or 220 VAC.
Sub-plate
Rc
NPT
NPTF
G
Port size
02
In the case of
—
CE compliant
1/4
alone
25A VQ2000 PW 02
Manifold Optional Parts
Blanking plate assembly
25A-VVQ2000V-10A-1
It is used by attaching on the manifold block for being
prepared for removing a valve for maintenance reasons
or planning to mount a spare valve, etc.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
33
Sub-plate Single Unit
Series
25A-VQ2000
Blanking plate assembly
25A-VVQ4000-10A-1 (Plug-in type)
25A-VVQ4000-10A-5 (Plug lead type)
It is used by attaching on the manifold block for being
prepared for removing a valve for maintenance
reasons or planning to mount a spare valve, etc.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
Description
EX124 SI unit
EX120 SI unit
Part no.
25A-VV5Q2/4
EX124D-SMJ1-X220
EX124D-SDN1-X220
EX120-SMJ1-X220
EX120-SDN1-X220
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
SI Unit Part No.
Note
CC-Link
DeviceNet™
CC-Link (VQ2000/Without option W)
DeviceNet™ (VQ2000/Without option W)
One-touch Fittings Part No.
Cylinder port
Metric size
1(P), 3(R) port Metric size
ø4 One-touch fitting (Straight type)
ø6 One-touch fitting (Straight type)
ø8 One-touch fitting (Straight type)
ø10 One-touch fitting (Straight type)
ø12 One-touch fitting (Straight type)
ø10 One-touch fitting (Straight type)
25A-VQ2000
90-VVQ1000-51A-C4
90-VVQ1000-51A-C6
90-VVQ1000-51A-C8
90-VVQ2000-51A-C10
Auto
Switches
Port size
Related
Products
Directional
Actuators Control
Valves
Manifold Optional Parts
34
Plug-in/Plug Lead: Single Unit
Base Mounted
Series
25A-VQ4000
How to Order Valves
[Option]
Port size
Body
Nil
0: Plug-in
sub-plate
02
03
Porting specifications
Nil
B
Plug-in
25A VQ4 1 0 1
Plug lead
25A VQ4 2 5 1
Type of actuation
1
2
3
4
5
6 Note)
2 position single
Rubber/2 position double
3 position closed center
3 position exhaust center
3 position pressure center
3 position double check
Note) Thread standard is
the same as standard
products.
Enclosure
CE compliant
Nil
—
Nil
Q CE compliant
W
Dustproof
Dust-tight /
Water-jets-proof type
(IP65)
Manual override
Nil: Non-locking
push type
(Tool required)
Note) For double check style,
refer to Best Pneumatics
No. 1.
Body
B: Slotted locking type
(Tool required)
Seal
5: Plug lead
sub-plate
1
Rubber seal
Light/Surge voltage suppressor
Function
Nil
Y (1)
R (2)
Nil
E
Standard type (1 W)
Low wattage type (0.5 W)
External pilot
Note 1) Applicable to DC specifications. Please
select when you expect to energize the
unit for extended periods of time.
Note 2) External pilot specifications are the
same as standard products.
Combination of external pilot and
perfect interface is not possible.
Note 3) When two or more symbols are
specified, indicate them alphabetically.
Yes
Without light, with surge voltage suppressor
Electrical entry
Coil voltage
1
2
3
4
5
6
G
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
Grommet
Series compatible
with secondary
batteries
Side ported
Bottom ported
Without sub-plate
(For manifold)
Rc 1/4
Rc 3/8
Lead wire
length 0.6 m
H
Lead wire
length 1.5 m
How to Order Sub-plates
[Option]
CE compliant
25A VQ4000
Series compatible
with secondary
batteries
Electrical entry
P
S
Plug-in conduit terminal
Plug lead
Enclosure
Dustproof
Nil
W Note) Dust-tight/Water-jets-proof type (IP65)
Note) It is not necessary for plug lead type.
35
Nil
Q
Porting specifications
Nil
B
—
CE compliant
Note 1) For bottom ported port
Side ported
size is RC 1/4 only.
Bottom ported (1)
Port size
02
03
Rc1/4
Rc3/8
Note 2) Thread standard is the
same as standard products.
∗ Specifications and dimensions for the 25A-series
are the same as standard products.
25A-VQ4000
08 C8
F
U 1
Series compatible with
secondary batteries
Series
4
CE compliant
Nil
Q
Symbol
Nil
Manifold
Plug-in unit
K (1)
Stations
…
01
18
Cylinder port
1 station
…
Option
None
Special wiring specifications
(Except double wiring)
Note 1) Specify the wiring specifications on the
manifold specification sheet.
Note 2) Refer to the standard products for with
control unit.
C8 With One-touch fitting for ø8
C10 With One-touch fitting for ø10
C12 With One-touch fitting for ø12
Rc 1/4
02
Rc 3/8
03
Bottom ported Rc 1/4
B
Mixed
CM
18 stations
—
CE compliant
Option
VQ4000
1
Cable (Length)
0
1
2
3
Note) As an option, the maximum number
of stations can be increased by
special wiring specifications.
Without cable
Cable length 1.5 m
Cable length 3 m
Cable length 5 m
Connector entry direction
D
U
D side entry
U side entry
How to Order Valves
25A
VQ 4 1 0 1
[Option]
5
Series compatible with
secondary batteries
Series
4
CE compliant
Nil
Q
VQ4000
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
3 position double check
Rubber seal
Non-locking push type (Tool required)
Locking type (Tool required)
Light /Surge voltage suppressor
Nil
E
Yes
Without light, with surge voltage suppressor
Coil voltage
Seal
1
—
CE compliant
Manual override
Nil
B
Type of actuation
1
2
3
4
5
6
Related
Products
25A VV5Q 4 1
[Option]
Function
Standard type (1 W)
Nil
Y (1) Low wattage type (0.5 W)
External pilot
R (2)
Note 1) Applicable to DC specifications. Please
select when you expect to energize the unit
for extended periods of time.
Note 2) External pilot specifications are the same as
standard products. Combination of external
pilot and perfect interface is not possible.
Note 3) When two or more symbols are specified,
indicate them alphabetically.
1
2
3
4
5
6
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
∗ Specifications and dimensions for
the 25A-series are the same as
standard products.
36
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
How to Order Manifold
Auto
Switches
Series
Directional
Actuators Control
Valves
Plug-in Unit/Base Mounted
F Kit (D-sub connector kit)
Plug-in Unit/Base Mounted
T Kit (Terminal block box kit)
Series
25A-VQ4000
How to Order Manifold
25A
VV5Q 4 1
08 C8
T
[Option]
0
CE compliant
Series compatible with
secondary batteries
Nil
Q
Series
4
Option
VQ4000
Box mounting position
O
D
Manifold
1
Plug-in unit
…
3 stations
…
18
18 stations
U side mounting
D side mounting
C8 With One-touch fitting for ø8
C10 With One-touch fitting for ø10
C12 With One-touch fitting for ø12
02
Rc 1/4
03
Rc 3/8
B
Bottom ported Rc 1/4
CM
Mixed
Note) 2 stations are used for mounting
the terminal block box. The
number of stations is the number
of manifold valves plus 2 stations
for the terminal block box. For 13
stations or more, specify the
wiring specifications by means of
the manifold specification sheet.
Symbol
Nil
K (2)
Cylinder port
Stations
03
—
CE compliant
Note) As an option, the maximum
number of stations can be
increased by special wiring
specifications.
N (3)
W
Option
None
Special wiring specifications
(Except double wiring,
for 13 stations or more)
Name plate
IP65 enclosure
Note 1) When two or more symbols are specified,
indicate them alphabetically.
Example) -KM
Note 2) Specify the wiring specifications on the
manifold specification sheet.
Note 3) Name plate is inlaid in the terminal block
cover.
Note 4) With control unit is the same as standard
products.
How to Order Valves
VQ 4 1 0 1
25A
[Option]
5
CE compliant
Series compatible with
secondary batteries
Nil
Q
Series
4
Enclosure
VQ4000
Nil
Type of actuation
1
2
3
4
5
6
W
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
3 position double check
Dustproof
Dust-tight / Water-jets-proof type
(IP65)
Manual override
Nil
B
Nil
E
Rubber seal
Function
Standard type (1 W)
Nil
Y (1) Low wattage type (0.5 W)
External pilot
R (2)
Note 1) Applicable to DC specifications.Please select when you
expect to energize the unit for extended periods of time.
Note 2) External pilot specifications are the same as standard
products. Combination of external pilot and perfect
interface is not possible.
Note 3) When two or more symbols are specified, indicate them
alphabetically.
Non-locking push type (Tool required)
Locking type (Tool required)
Light / Surge voltage suppressor
Seal
1
37
—
CE compliant
Yes
Without light, with surge voltage suppressor
Coil voltage
1
2
3
4
5
6
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
∗ Specifications and dimensions for the 25A-series are
the same as standard products.
25A-VQ4000
08 C8
L
D
Series compatible with
secondary batteries
Series
4
CE compliant
Nil
Q
VQ4000
Symbol
Nil
W
Plug-in unit
Stations
…
—
CE compliant
Option
Manifold
1
01
1 stations
…
16
16 stations
Option
None
IP65 enclosure
Cable (Length)
0
1
2
Cylinder port
Cable length 0.6 m
Cable length 1.5 m
Cable length 3 m
Connector locations
C8 With One-touch fitting for ø8
C10 With One-touch fitting for ø10
C12 With One-touch fitting for ø12
02
Rc 1/4
03
Rc 3/8
B
Bottom ported Rc 1/4
CM
Mixed
D
U
D side entry
U side entry
How to Order Valves
25A
VQ 4 1 0 1
[Option]
5
CE compliant
Series compatible with
secondary batteries
Series
4
Nil
Q
Nil
W
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
3 position double check
1
Dustproof
Dust-tight/Water-jets-proof type
(IP65)
Manual override
Nil
B
Nil
E
Rubber seal
Function
Standard type (1 W)
Low wattage type (0.5 W)
External pilot
Note 1) Applicable to DC specification. Please select when you
expect to energize the unit for extended periods of time.
Note 2) External pilot specifications are the same as standard
products. Combination of external pilot and perfect
interface is not possible.
Note 3) When two or more symbols are specified, indicate them
alphabetically.
Non-locking push type (Tool required)
Locking type (Tool required)
Light /Surge voltage suppressor
Seal
Nil
Y (1)
R (2)
—
CE compliant
Enclosure
VQ4000
Type of actuation
1
2
3
4
5
6
Related
Products
25A VV5Q 4 1
[Option]
Yes
Without light, with surge voltage suppressor
Coil voltage
1
2
3
4
5
6
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
∗ Specifications and dimensions for the 25A-series are
the same as standard products.
38
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
How to Order Manifold
Auto
Switches
Series
Directional
Actuators Control
Valves
Plug-in Unit/Base Mounted
L Kit (Lead wire cable)
Plug-in Unit/Base Mounted
S Kit (Serial transmission unit)
25A-VQ4000
Series
Note) Refer to “SI Unit Part
No.” when ordering the
[Option]
CE-compliant SI unit.
How to Order Manifold
25A
VV5Q 4 1
08 C8
S
D V
CE compliant
Nil
Q
Series compatible with
secondary batteries
Option
Series
4
Symbol
Nil
VQ4000
K (2)
Manifold
1
—
CE compliant
W
Plug-in unit
Note 1) When two or more symbols are specified, indicate
them alphabetically. Example) -KW
Note 2) Specify the wiring specifications in the manifold
specification sheet.
Note 3) With control unit is the same as standard products.
Note 4) The release valve and the pressure switch on the
manifold with control unit are connected to another
power supply. Cable length is 0.6 m for L kit.
Stations
Note) 2 stations are used for
03
3 stations
…
mounfing SI unit. The …
number of stations is the 18
18 stations
number of manifold
valves plus 2 stations
for SI unit. For 11
stafions or more, specify
the wiring specifications
Cylinder ports
by means of the
C8
With
One-touch
fitting for ø8
manifold specification
C10 With One-touch fitting for ø10
sheet.
C12 With One-touch fitting for ø12
02
Rc 1/4
03
Rc 3/8
B
Bottom ported Rc 1/4
CM
Mixed
Option
None
Special wiring specifications
(Except double wiring, for 11 stations or more)
IP65 enclosure
SI unit
0
Q
V
Without SI unit
DeviceNet™
CC-Link
SI unit mounting position
D D side mounting
U U side mounting
How to Order Valves
25A
Series compatible with
secondary batteries
VQ 4 1 0 1
[Option]
5
CE compliant
Nil
Q
Series
4
VQ4000
Enclosure
Type of actuation
1
2
3
4
5
6
Nil
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
3 position double check
W
Nil
B
Standard type (1 W)
Low wattage type (0.5 W)
External pilot
Note 1) Applicable to DC specifications. Please select when you
expect to energize the unit for extended periods of time.
Note 2) External pilot specifications are the same as standard
products. Combination of external pilot and perfect
interface is not possible.
Note 3) When two or more symbols are specified, indicate them
alphabetically.
39
Non-locking push type (Tool required)
Locking type (Tool required)
Light /Surge voltage suppressor
Rubber seal
Nil
E
Function
Nil
Y (1)
R (2)
Dustproof
Dust-tight/Water-jets-proof type
(IP65)
Manual override
Seal
1
—
CE compliant
Yes
Without light, with surge voltage suppressor
Coil voltage
5
24 VDC
∗ Specifications and dimensions for the 25A-series
are the same as standard products.
Plug Lead Unit/Base Mounted
C Kit (Connector kit)
[Option]
Directional
Actuators Control
Valves
25A-VQ4000
How to Order Manifold
08 C8
C
W
Nil
Q
Refer to the standard products.
Manifold
Kit type
Stations
…
Symbol
Nil
W
Control unit
VQ4000
Plug lead unit
5
—
CE compliant
Option
Series
4
Related
Products
CE compliant
Series compatible with
secondary batteries
01
1 stations
…
16
16 stations
C
kit (Connector)
C
Connector kit
Option
None
IP65 enclosure
Cylinder port
C8 With One-touch fitting for ø8
C10 With One-touch fitting for ø10
C12 With One-touch fitting for ø12
02
Rc 1/4
03
Rc 3/8
B
Bottom ported Rc 1/4
CM
Mixed
Max. 16 stations
Refer to Best Pneumatics
No. 1 for wiring specifications.
How to Order Valves
25A VQ 4 1 5 1
5 G
CE compliant
Nil
Q
Enclosure
Series compatible with
secondary batteries
Series
4
Nil
W
Manual override
Light/Surge voltage suppressor
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
3 position double check
Nil
E
G
Rubber seal
Grommet
1
Function
Standard type (1 W)
Low wattage type (0.5 W)
External pilot
Note 1) Applicable to DC specifications. Please select
when you expect to energize the unit for
extended periods of time.
Note 2) External pilot specifications are the same as
standard products. Combination of external pilot
and perfect interface is not possible.
Note 3) When two or more symbols are specified,
indicate them alphabetically.
Yes
Without light, with surge
voltage suppressor
B:
Nil:
Non-locking push type Locking type
(Tool required) (Tool required)
Electrical entry
Seal
Nil
Y (1)
R (2)
Dustproof
Dust-tight/Water-jets-proof type
(IP65)
VQ4000
Type of actuation
1
2
3
4
5
6
—
CE compliant
Lead wire
length
0.6 m
H
Lead wire
length
1.5 m
Coil voltage
1
2
3
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
4
5
6
220 VAC (50/60 Hz)
24 VDC
12 VDC
∗ Specifications and dimensions for the 25A-series are
the same as standard products.
40
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
VV5Q 4 5
25A
Auto
Switches
Series
Series
25A-VQ4000
Manifold Option Parts
Blanking plate assembly
25A-VVQ4000-10A-1 (Plug-in type)
25A-VVQ4000-10A-5 (Plug lead type)
It is used by attaching on the manifold block
for being prepared for removing a valve for
maintenance reasons or planning to mount a
spare valve, etc.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
SI Unit Part No.
Part no.
EX124D-SMJ1-X220
EX124D-SDN1-X220
EX124U-SMJ1-X220
EX124U-SDN1-X220
Note
CC-Link/D side mounting
DeviceNet™/D side mounting
CC-Link/U side mounting
DeviceNet™/U side mounting
Port size
ø4 One-touch fitting (Straight type)
ø6 One-touch fitting (Straight type)
ø8 One-touch fitting (Straight type)
Metric size
ø10 One-touch fitting (Straight type)
ø12 One-touch fitting (Straight type)
ø10 One-touch fitting (Straight type)
Metric size
25A-VQ4000
Description
EX124 SI unit
One-touch Fittings Part No.
Cylinder port
1(P), 3(R) port
41
90-VVQ4000-50B-C8
90-VVQ4000-50B-C10
90-VVQ4000-50B-C12
How to Order Manifold
25A SS5Q23
08 FD2
Series compatible with
secondary batteries
1 station
16 stations
16 Note)
Note) The maximum number of
stations depends on the
type of electrical entries.
Manifold mounting
DIN rail mounting style
Direct mounting style
D
E Note)
CE compliant
Nil
Q
Option
Stations
01
D
Nil
02 to 16 (1)
B (2)
K (3)
N
R
None
DIN rail length specified
Back pressure check valve
Special wiring specifications (Except double wiring)
With name plate (Side ported only)
External pilot specifications
—
CE compliant
1(P), 3(R) port size
Nil
00T
1(P), 3(R) port
One-touch fittings for ø10
1(P), 3(R) port
One-touch fittings for ø3/8"
Note 1) Specify DIN rail length with “D at the end. (Enter the number of stations inside .)
The number of stations that may be displayed is longer than the manifold number of
stations.
Example: -D08
Note 2) When installing back pressure check valves only on the stations required, enter the
part number and specify the mounting stations on a manifold specification sheet.
Note 3) Standard wiring specifications are for double wiring. Indicate wiring specifications for
single wiring or mixed single and double wiring, or when exceeding the standard
maximum number of stations. (Except L kit.)
Note 4) For specifying two or more options, enter them alphabetically. Example: -BKN
∗ Manifold option parts are the same as standard products.
Electrical entry
Lead wire
connector
location
Kit type
F kit
The electric
parts are made
of copper.
D-sub D side
connector kit
Mounting screw:
Stainless steel
U side
One-touch fitting
Body: Stainless steel
Cable specifications
Station
Max. number
(2)
of stations for Max. number
special wiring of solenoids
specifications
D side
D-sub connector (25P) kit, without cable
D-sub connector (25P) kit, with 1.5 m cable
D-sub connector (25P) kit, with 3.0 m cable
D-sub connector (25P) kit, with 5.0 m cable
1 to 12 stations 16 stations
24
TD0
D side
Terminal block box kit
1 to 10 stations 16 stations
16
LD0
LU0
LD1
LU1
LD2
LU2
D side
U side
D side
U side
D side
U side
FD0
FD1
FD2
FD3
T kit
Terminal block
box kit
L kit
Mounting screw: Stainless steel
One-touch fitting
Body: Stainless steel
Lead wire kit
S kit
Lead wire kit with 0.6 m cable
Lead wire kit with 1.5 m cable
1 to 12 stations
—
—
Lead wire kit with 3.0 m cable
Mounting screw:Stainless steel
SDQ
The electric
parts are made
of copper.
1 to 8 stations 16 stations
16
CC-Link
1 to 8 stations 16 stations
16
D side
One-touch fitting
Body: Stainless steel
Serial transmission kit
EX140 integrated-type (for output)
serial transmission system (3)
DeviceNet™
SDV
Note 1) The maximum number of stations should not be more than the maximum number of solenoids. (The number of solenoids are counted as:
1 for single solenoids and 2 for type 3P and 4P double solenoids.)
Note 2) Refer to Best Pneumatics No. 1 for the details of EX140 integrated-type (for output) serial transmission system. Refer to “SI unit part no.”
when ordering the CE-compliant SI unit.
SI unit part no.
Symbol
Protocol type
SDQ DeviceNet™
SDV CC-Link
SI unit part no.
EX140-SDN1-X220
EX140-SMJ1-X220
Page
P.46
Blanking plate assembly
25A-SSQ2000-10A-3
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
42
Related
Products
[Option]
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
25A-SQ2000
Auto
Switches
Series
Directional
Actuators Control
Valves
Plug-in Unit
Series
25A-SQ2000
How to Order Valves
25A SQ2 1 3 1
5
[Option]
C6
CE compliant
Series
compatible
with
secondary
batteries
—
CE compliant
Nil
Q
With/Without manifold block
Nil
M
With manifold
block
Without manifold
block
Type of actuation
MB
With manifold block, built-in
back pressure check valve
2 position single
1
2 position double(Latching)
(Metal seal, Rubber seal)
2
2 position double (Double solenoid) (1)
(Rubber seal)
3
3 position closed center
4
3 position exhaust center
5
3 position pressure center
∗ Lead wire is not included. ∗ Lead wire is not included.
• When ordering
with manifolds
• When only valves
are required.
Port plug mounting port
(2)
4 position dual 3 port valve
A (N.C./N.C.)
Nil
A
B
(2)
4 position dual 3 port valve
B (N.O./N.O.)
(2)
4 position dual 3 port valve
C (N.C./N.O.)
C4
C6
C8
L4
L6
L8
Rubber seal
Side
ported
(1)
Top
ported
Manual override
Nil
Non-locking push type
(Tool required)
Function
D
One-touch fittings for ø4
One-touch fittings for ø6
One-touch fittings for ø8
One-touch fittings for ø4
One-touch fittings for ø6
One-touch fittings for ø8
Note 1) Can be changed to side ported configuration.
Note 2) Refer to the standard products for the inch-size One-touch fittings.
Seal
Nil
None
Port 4(A)
Port 2(B)
Cylinder port
Note 1) For double solenoid
specification, the
function symbol below is
“D”.
Note 2) Only rubber seal types
are applicable.
1
For adding stations
Standard type (1.0 W DC)
2 position double
(Double solenoid specifications)
B Note)
Locking type
(Tool required)
D Note)
Slide locking type (Manual type)
∗ Only side ported type applicable
(Latching type: Nil)
Negative common
Y(1)(2) Low wattage type (0.5 W DC)
R(3) External pilot specifications
N
Note 1) Except double (latching) type.
Note 2) Please select when you expect to
energize the unit for extended
periods of time.
Note 3) Except dual 3 port valves.
Note 4) When two or more symbols are
specified, indicate them
alphabetically.
Note) Except double (latching) type.
Coil voltage
5
6
24 VDC
12 VDC
Note 1) Light/Surge voltage suppressor
is built-in.
Note 2) S kit: 24 VDC only
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
43
[Option]
How to Order Manifold
25A SS5Q24
08 FD2
D
Nil
Q
Related
Products
CE compliant
Series compatible
with secondary
batteries
—
CE compliant
1(P), 3(R) port size
Nil
00T
Stations
01
1 station
16 Note)
16 stations
1(P), 3(R) port, One-touch fittings for ø10
1(P), 3(R) port, One-touch fittings for ø3/8"
Option
Nil
02 to 16 (1)
B
K (2)
N
R
Note) The maximum number of
stations depends on the
type of electrical entries.
Manifold mounting
D
E Note)
DIN rail mounting style
Direct mounting style
Note) Type E is only available
with a C kit.
None
DIN rail length specified
Back pressure check valve
Special wiring specifications (Except double wiring)
With name plate (Side ported only)
External pilot specifications
Note 1) Specify DIN rail length with “D at the end. (Enter the
number of stations inside .)
The number of stations that may be displayed is
longer than the manifold number of stations.
Example: -D08
Note 2) When installing back pressure check valves only on
the stations required, enter the part number and
specify the mounting stations on a manifold
specification sheet.
Note 3) Standard wiring specifications are for double wiring.
Indicate wiring specifications for single wiring or mixed
single and double wiring, or when exceeding the
standard maximum number of stations. (Except C kit.)
Note 4) For specifying two or more options, enter them
alphabetically. Example: -BKN
∗ Manifold option parts are the same as standard products.
Electrical entry
Lead wire
connector
location
Kit type
Mounting screw:
Stainless steel
F kit
The electric
parts are made
of copper.
D side
D-sub connector kit
C kit
Connector kit
U side
One-touch fitting
Body: Stainless steel
FD0
FD1
FD2
FD3
D side
C
—
Cable specifications
Stations
Max. number
(1)
of stations for Max. number
special wiring of solenoids
specifications
D-sub connector (25P) kit, without cable
D-sub connector (25P) kit, with 1.5 m cable
D-sub connector (25P) kit, with 3.0 m cable
D-sub connector (25P) kit, with 5.0 m cable
1 to 12 stations 16 stations
24
Connector kit
1 to 16 stations
—
Mounting screw:
Stainless steel
—
One-touch fitting
Body: Stainless steel
Note 1) The maximum number of stations should not be more than the maximum number of solenoids. (The number of solenoids are counted as:
1 for single solenoids and 2 for type 3P and 4P double solenoids.)
∗ Refer to Best Pneumatics No. 1 for manifold spare parts.
Blanking plate assembly
25A-SSQ2000-10A-4
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
44
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
25A-SQ2000
Auto
Switches
Series
Directional
Actuators Control
Valves
Plug Lead Unit
Series
25A-SQ2000
How to Order Valves
25A SQ2 1 4 1
5 L
[Option]
C6
CE compliant
Series
compatible
with
secondary
batteries
Nil
Q
—
CE compliant
With/Without manifold block
M
MB
With manifold With manifold block, built-in
block
back pressure check valve
Nil
Without manifold
block
Type of actuation
2 position single
1
2 position double(Latching)
(Metal seal, Rubber seal)
2
2 position double (Double solenoid) (1)
(Rubber seal)
3
3 position closed center
4
3 position exhaust center
5
3 position pressure center
(2)
4 position dual 3 port valve
∗ Lead wire is not included. ∗ Lead wire is not included.
• When ordering with
manifolds
• When only valves
are required.
Port plug mounting port
(2)
4 position dual 3 port valve
B (N.O./N.O.)
Cylinder port
4 position dual 3 port valve
C4
C6
C8
L4
L6
L8
C (N.C./N.O.)
Note 1) For double solenoid
specification, the
function symbol below is
“D”.
Note 2) Only rubber seal types
are applicable.
Rubber seal
D
Side
ported
(1)
Top
ported
Manual override
Nil
Non-locking push type
(Tool required)
Function
Nil
One-touch fitting for ø4
One-touch fitting for ø6
One-touch fitting for ø8
One-touch fitting for ø4
One-touch fitting for ø6
One-touch fitting for ø8
Note 1) Can be changed to side ported configuration.
Note 2) Refer to the standard products for the inch-size One-touch fittings.
Seal
1
None
Port 4(A)
Port 2(B)
Nil
A
B
A (N.C./N.C.)
(2)
For adding stations
Standard type (1.0 W DC)
2 position double
(Double solenoid specifications)
(Latching type: Nil)
Negative COM
N
Y(1)(2) Low wattage type (0.5 W DC)
R(3) External pilot specifications
B Note)
Locking type
(Tool required)
D Note)
Slide locking type (Manual type)
∗ Only side ported type applicable
Note) Except double (latching) type.
Note 1) Except double (latching) type.
Note 2) Please select when you expect to
energize the unit for extended
periods of time.
Note 3) Except dual 3 port valves.
Note 4) When two or more symbols are
specified, indicate them
alphabetically.
Electrical entry
L
Plug connector type
with 300 mm lead wire
LO
Plug connector type
without connector
Coil voltage
5
6
24 VDC
12 VDC
Note) Light/Surge
voltage
suppressor is
built-in.
For F, P, J kit manifolds Note)
Note) Indicate “LO” when ordering centralized wiring type manifolds, F, P,
and J kits, since the lead wire will be attached to the manifold side.
∗ Specifications and dimensions for the 25A-series are the same as standard products.
45
Plug Lead Unit
Series
25A-SQ2000
Part no.
25A-SS5Q23
EX140-SMJ1-X220
EX140-SDN1-X220
Description
EX140 SI unit
Directional
Actuators Control
Valves
SI Unit Part No.
Note
CC-Link
DeviceNetTM
One-touch Fittings Part No.
1(P), 3(R) port
Metric size
ø4 One-touch fitting (Straight type)
ø6 One-touch fitting (Straight type)
ø8 One-touch fitting (Straight type)
ø10 One-touch fitting (Straight type)
90-VVQ1000-51A-C4
90-VVQ1000-51A-C6
90-VVQ4000-51A-C8
90-VVQ2000-51A-C10
Related
Products
Metric size
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Cylinder
port
25A-SQ2000
Auto
Switches
Port size
46
5 Port Solenoid Valve
Base Mounted
Series 25A-VQZ1000
Single Unit
Plug Lead Unit
[Option]
How to Order Valve
25A VQZ 1 1 5 1
5 M
1 01
CE compliant
Series compatible
with secondary
batteries
Series
Nil
Q
Note) DC-type only.
1 VQZ1000 body width 10 mm
Port size
Symbol
Port size
Without sub-plate
Nil
Rc1/8
01
Type of actuation
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
3 port for mixture mounting N.C.
3 port for mixture mounting N.O.
1
2
3
4
5
8
9
—
CE compliant
Manual override
Nil: Non-locking B: Locking type
push type (Tool required)
(Tool
required)
Body type
+-
+-
5 Base mounted
Seal type
1
Electrical entry
Rubber seal
LO: L-type
M: M-type
MO: M-type
G: Grommet L: L-type
plug
plug
plug
plug
(DC speciconnector
connector
connector
connector
fication)
with lead
without
with lead
without
wire
connector
wire
connector
Function
Symbol
Specifications
Nil Standard
B
High speed response type
R
External pilot type
BR
High speed response/External pilot type
DC
(0.35 W)
AC


(0.9 W)

—


(0.9 W)
—

With light/
With light/
With light/
With light/
surge voltage surge voltage surge voltage surge voltage
suppressor
suppressor
suppressor
suppressor
-+
+−
+-
Coil voltage
1
2
3
4
5
6
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC [115 VAC] (50/60 Hz)
220 VAC [230 VAC] (50/60 Hz)
24 VDC
12 VDC
Caution
Use standard (DC) specification for continuous duty.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
47
[Option]
How to Order Manifold
CE compliant
Series
Series compatible
with secondary
batteries
1
Manifold type
Option
Base mounted
Nil
R
Stations
02 2 stations
None
External pilot type
Kit type
…
…
—
CE compliant
Nil
Q
VQZ1000
5
Related
Products
25A VV5QZ 1 5 08 C6 C R
20 20 stations
C Connector
Port size [4(A), 2(B) port]
Symbol
C4
C6
M5
CM Note)
Port size
ø4 One-touch fitting
ø6 One-touch fitting
M5 thread
Mixture of port sizes
Note) Specify port mixture/with port plug by the manifold specification sheet.
Port mixture and port plug are available only for One-touch fitting type.
How to Order Valve
25A VQZ 1 1 5 1
5 M
CE compliant
Series compatible
with secondary
batteries
Nil
Q
Series
Manual override
Type of actuation
Nil
B
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
3 port for mixture mounting N.C.
3 port for mixture mounting N.O.
Body type
Seal type
1
Function
B
High speed response type
R
External pilot type
High speed response/
External pilot type
DC
(0.35 W)

(0.9 W)


(0.9 W)

Caution
Use standard (DC) specification for continuous duty.
Symbol
Electrical entry
G
L
LO
M
MO
Grommet (DC specification)
L-type plug connector with lead wire
L-type plug connector without connector
M-type plug connector with lead wire
M-type plug connector without connector
Light/surge
voltage
suppressor
None
Yes
Coil voltage
Rubber seal
Symbol
Specifications
Nil
Standard
Non-locking push type (Tool required)
Locking type (Tool required)
Electrical entry
5 Base mounted
BR
—
CE compliant
Note) DC-type only.
1 VQZ1000 body width 10 mm
1
2
3
4
5
8
9
1
AC

—

1
2
3
4
5
6
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC [115 VAC] (50/60 Hz)
220 VAC [230 VAC] (50/60 Hz)
24 VDC
12 VDC
—
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
48
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Series 25A-VQZ1000
Manifold Connector Kit
Plug Lead Unit
Auto
Switches
Base Mounted
Directional
Actuators Control
Valves
5 Port Solenoid Valve
5 Port Solenoid Valve
Body Ported
Series 25A-VQZ1000
Single Unit
Plug Lead Unit
[Option]
How to Order Valve
25A VQZ 1 1 2 1
5 M
1 C6
CE compliant
Series
compatible
with secondary
batteries
Note) DC-type only.
Option
Series
Nil: None
F: With bracket
2 position
single type
only
1 VQZ1000 body width 10 mm
Type of actuation
1
2
3
4
5
8
9
—
CE compliant
Nil
Q
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
3 port for mixture mounting N.C.
3 port for mixture mounting N.O.
+-
Bracket
Port size [4(A), 2(B) port]
Symbol
Port size
C4 ø4 One-touch fitting
C6 ø6 One-touch fitting
M5 M5 thread
Note) 3 port for mixture mounting is only
available for port size C4 or C6.
Manual override
Nil: Non-locking B: Locking type
push type
(Tool required)
(Tool required)
+-
+-
Electrical entry
G: Grommet L: L-type
(DC speciplug
fication)
connector
with lead
wire
With light/
surge voltage
suppressor
LO: L-type
plug
connector
without
connector
With light/
surge voltage
suppressor
Body type
2
M: M-type
plug
connector
with lead
wire
With light/
surge voltage
suppressor
MO: M-type
plug
connector
without
connector
With light/
surge voltage
suppressor
-+
Body ported
+−
+-
Seal type
1
Rubber seal
Function
Symbol
Specifications
DC
AC
Nil
Standard
(0.35 W)

B
High speed response type
(0.9 W)
—


Caution
Use standard (DC) specification for continuous duty.
49
Coil voltage
1
2
3
4
5
6
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC [115 VAC] (50/60 Hz)
220 VAC [230 VAC] (50/60 Hz)
24 VDC
12 VDC
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
[Option]
How to Order Manifold
CE compliant
Series
Series compatible with
secondary batteries
1
Nil
Q
VQZ1000
Manifold type
2
Related
Products
25A VV5QZ 1 2 08 C
—
CE compliant
Kit type
Body ported
C Connector
Stations
…
…
02 2 stations
20 20 stations
How to Order Valve
25A VQZ 1 1 2 1
5 M
1 C6
Series
compatible
with secondary
batteries
CE compliant
Nil
Q
Series
Port size [4(A), 2(B) port]
Symbol
C4
C6
M5
Type of actuation
1
2
3
4
5 Note)
8 Note)
9 Note)
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
3 port for mixture mounting N.C.
3 port for mixture mounting N.O.
Nil
B
Body ported
Seal type
Rubber seal
Function
Symbol
Nil
B
Non-locking push type (Tool required)
Locking type (Tool required)
Electrical entry
Body type
1
Port size
ø4 One-touch fitting
ø6 One-touch fitting
M5 thread
Manual override
Note) 3 port for mixture mounting is only
available for port size C4 or C6.
2
—
CE compliant
Note) DC-type only.
1 VQZ1000 body width 10 mm
Specifications
DC
AC
Standard
(0.35 W)


High speed response type
(0.9 W)
—

Caution
Use standard (DC) specification for continuous duty.
Symbol
Electrical entry
G
L
LO
M
MO
Grommet (DC specification)
L-type plug connector with lead wire
L-type plug connector without connector
M-type plug connector with lead wire
M-type plug connector without connector
Light/surge
voltage suppressor
None
Yes
Coil voltage
1
2
3
4
5
6
Directional
Actuators Control
Valves
Series 25A-VQZ1000
Manifold Connector Kit
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC [115 VAC] (50/60 Hz)
220 VAC [230 VAC] (50/60 Hz)
24 VDC
12 VDC
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
50
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
Plug Lead Unit
Auto
Switches
Body Ported
5 Port Solenoid Valve
Plug-in Unit
Base Mounted
25A-VQ1000/2000
Double check block (Separated)
Series
How to Order
Double check block
25A VQ1000 FPG C4 M5 F
Option
Series compatible with
secondary batteries
M5
C3
C4
C6
IN side port size
OUT side port size
M5 thread
ø3.2 One-touch fitting
ø4 One-touch fitting
ø6 One-touch fitting
M5
C3
C4
C6
M5 thread
ø3.2 One-touch fitting
ø4 One-touch fitting
ø6 One-touch fitting
Manifold (DIN rail mounting)
Nil
F
D
N
None
With bracket
DIN rail mounting
(For manifold)
Name plate
Note) When two or more
symbols are specified,
indicate them
alphabetically.
Example) -DN
25A VVQ1000 FPG 06
Series compatible with
secondary batteries
Stations
01
16
1 station
…
<Ordering example>
25A-VVQ1000-FPG-06…6-station manifold
∗ 25A-VQ1000-FPG-C4M5-D;
Double
3set
∗ 25A-VQ1000-FPG-C6M5-D; check block
3set
…
When ordering a double check block,
order the DIN rail mounting [-D].
16 stations
Bracket Assembly
Part no.
Tightening torque
25A-VQ1000-FPG-FB 0.22 to 0.25 N·m
Double check block
25A VQ2000 FPG 01 01 F
Series compatible with
secondary batteries
Option
Nil
IN side port size
01
02
C6
C8
Rc 1/8
Rc 1/4
ø6 One-touch fitting
ø8 One-touch fitting
OUT side port size
D
Rc 1/8
Rc 1/4
ø6 One-touch fitting
ø8 One-touch fitting
F
N
01
02
C6
C8
Manifold (DIN rail mounting)
None
DIN rail mounting
(For manifold)
With bracket
Name plate
Note) When two or more
symbols are specified,
indicate them
alphabetically.
Example) -DN
25A VVQ2000 FPG 06
Series compatible with
secondary batteries
Stations
16
1 station
…
<Ordering Example>
25A-VVQ2000-FPG-06…6-station manifold
∗ 25A-VQ2000-FPG-C6C6-D;
3set
Double
∗ 25A-VQ2000-FPG-C8C8-D; check block
3set
01
…
When ordering a double check block,
order the DIN rail mounting [-D].
16 stations
Bracket Assembly
Tightening torque
Part no.
0.8 to 1.0 N·m
25A-VQ2000-FPG-FB
∗ Specifications and dimensions for the 25A-series are the same as standard products.
51
25A-VP342/542/742
Note) Only DIN and conduit terminal types
are available for AC mode.
Refer to the electrical entry for details.
25A VP 3 4 2
Series compatible with
secondary batteries
5 D
1 01
Thread type
Series
3
5
7
Nil
F
N
T
VP300
VP500
VP700
Pilot type
Nil
R
Rc
G
NPT
NPTF
Type of actuation
Internal pilot
External pilot
Pressure specification
Nil
K
A N.C. (Normally closed)
B N.O. (Normally open)
Standard (0.7 MPa)
High-pressure type (1.0 MPa)
Bracket
Coil specification
Nil
T
A
Related
Products
Body ported
Standard
With power saving circuit (DC only)
Note) Be sure to select the power
saving circuit type when it is
continuously energized for a long
time.
∗ T type is only available for DC mode.
When T is selected, only Z type of
light/surge voltage suppressor is
available.
Nil
F
Rated voltage
DC
5 24 VDC
6 12 VDC
AC (50/60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
7 240 VAC
B 24 VAC
Without bracket
With bracket
Port size
Symbol Port size VP300 VP500 VP700
1/8
01

—
—
1/4
02


—
3/8
03
—


1/2
04
—
—

Electrical entry
DIN
DIN
Conduit
(EN175301-803)
terminal
terminal
terminal
[IP65 compatible] [IP65 compatible] [IP65 compatible]
Manual override
Nil: Non-locking
push type
D: Push-turn locking
slotted type
E: Push-turn locking
lever type
D: With connector Y: With connector T: Conduit
terminal
DC
CE
compliant AC
Light /surge voltage suppressor
Nil
S
Z
R
U
Without light /surge voltage suppressor
With surge voltage suppressor
With light /surge voltage suppressor
With surge voltage suppressor (Non-polar)
With light /surge voltage suppressor (Non-polar)
DC AC
 
Note)
 —
 
 —
 —
Note) There is no S option for AC mode, since a rectifier prevents
surge voltage generation.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
52
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
How to Order
Auto
Switches
Series
Directional
Actuators Control
Valves
Rubber Seal
3 Port/Pilot Poppet Type
Rubber Seal
3 Port/Pilot Poppet Type
Series 25A-VP344/544/744
Note) Only DIN and conduit terminal types
are available for AC mode.
Refer to the electrical entry for details.
How to Order
Base mounted
25A VP 3 4 4
Series compatible with
secondary batteries
5 D
1 01
Thread type
Series
3
5
7
Nil
F
N
T
VP300
VP500
VP700
Internal pilot
External pilot
A N.C. (Normally closed)
B N.O. (Normally open)
Pressure specification
Nil
K
Standard (0.7 MPa)
High-pressure type (1.0 MPa)
Coil specification
Nil
T
Rc
G
NPT
NPTF
Type of actuation
Pilot type
Nil
R
A
Standard
With power saving circuit (DC only)
Note) Be sure to select the power saving
circuit type when it is continuously
energized for a long time.
∗ T type is only available for DC mode.
When T is selected, only Z type of
light/surge voltage suppressor is
available.
Port size (Sub-plate)
Rated voltage
DC
5 24 VDC
6 12 VDC
Symbol Port size VP300 VP500 VP700
Without sub-plate∗
Nil
1/8

—
—
01
1/4


—
02
3/8
—


03
1/2
—
—

04
AC (50/60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
7 240 VAC
B 24 VAC
∗ With a gasket and two mounting bolts.
Electrical entry
DIN
Conduit
(EN175301-803)
terminal
terminal
[IP65 compatible] [IP65 compatible] [IP65 compatible]
DIN
terminal
Manual override
Nil: Non-locking
push type
D: Push-turn locking
slotted type
E: Push-turn locking
lever type
D: With connector Y: With connector T: Conduit
terminal
DC
CE
compliant AC
Light /surge voltage suppressor
Nil
S
Z
R
U
Without light /surge voltage suppressor
With surge voltage suppressor
With light /surge voltage suppressor
With surge voltage suppressor (Non-polar)
With light /surge voltage suppressor (Non-polar)
DC AC
 
Note)
 —
 
 —
 —
Note) There is no S option for AC mode, since a rectifier prevents
surge voltage generation.
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
53
25A-VT317
Rubber Seal
Series
[Option]
Note) CE compliant: For DIN
terminal type.
How to Order
02
Related
Products
G
Body type
T
O
Body ported
Manifold
Thread type
Valve option
Nil
E∗
V∗
Standard type
Continuous duty type
For vacuum
CE compliant
Rated voltage
100 VAC,50 60
200 VAC,50 60
110 VAC,50 60
220 VAC,50 60
24 VDC
12 VDC
240 VAC,50 60
Other
—
CE compliant∗
Nil
Q
∗ Semi-standard
1
2
3∗
4∗
5
6∗
7∗
9∗
Rc
G
NPT
NPTF
Nil
F
N
T
Series compatible with
secondary batteries
Note) Applicable only for
DIN terminal type.
Hz
Hz
Hz
Hz
Port size
Without port
(For manifold)
1 4 (8A)
Nil
Hz
02
Note) Applicable only for DIN
terminal type.
∗ Semi-standard
Electrical entry
G
H
C
T
D
Grommet, 300 mm lead wire
Grommet, 600 mm lead wire
Conduit
Conduit terminal
DIN terminal
Light/Surge voltage suppressor CE compliant
CE compliant
—
—
—
—

Electrical
entry
Symbol
Nil
S
Z
G
H
C
T
D
D Only
—
—
—
—
—
 Note)  Note)  Note) 
— — — 





S:With surge voltage suppressor
Note) Refer to the figure below.
Z: With light /surge voltage suppressor
∗ As to the case of rated voltage
[Others (9)], please contact SMC.
Surge voltage suppressor mounting part
(For “G”)
Surge voltage suppressor
Manifold
Model
Applicable manifold type
VO317(-Q)
Common or individual exhaust
Accessory
O-ring (P10, 4 pcs.) Note)
Bolts (M4 x 0.7 x 20, 2 pcs.)
Note) It is not applied to “Continuous duty type”. Refer to the accessories in Best Pneumatics No. 1.
∗ Specifications and dimensions for the 25A-series are the same as standard products.
54
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
1
Auto
Switches
25A V T 317
Directional
Actuators Control
Valves
3 Port Solenoid Valve
Direct Operated Poppet Type
3 Port Solenoid Valve
Direct Operated Poppet Type
25A-VG342
Rubber Seal
Series
[Option]
Note) CE compliant: For DIN
terminal only
How to Order
Low power consumption
4.8 W DC (Standard type)
2 W DC (Energy-saving type)
25A VG342
No lubrication required
Possible to use in vacuum
or under low pressures
5 D
04
A
Series compatible with
secondary batteries
External pilot
Vacuum: Up to –101.2 kPa
Low pressure: 0 to 0.2 MPa
CE compliant
Nil
Valve option
Nil
R
Changeable actuation:
N.C., N.O., or external pilot
Can be used as a selector
or divider valve (External pilot)
Internal pilot
External pilot
Pilot valve option
Rated voltage
5
6∗
—
Q CE compliant Note)
Note) Applicable only for
DIN terminal type
Nil
Y∗
E∗
24 VDC
12 VDC
Note) Applicable only for DIN
terminal type
∗ Semi-standard
Standard type
Energy-saving type (DC only)
Continuous duty type
∗ Option
Passage symbol
Nil
A
B
Electrical entry CE compliant
D
DIN terminal
External pilot
N.C. (Normally closed)
N.O. (Normally open)

Thread type
Nil
Light /Surge voltage suppressor
Nil
Z
None
With light /surge voltage suppressor
(Except grommet type)
Rc
Port size
04
06
10
12
34
1
∗ Specifications and dimensions for the 25A-series are the
same as standard products.
55
25A-VHK
RoHS
How to Order
02S
Series compatible with
secondary batteries
Related
Products
02S
Bracket
Valve model
2
3
Nil
L
2 port valve
3 port valve
∗ Bracket and screws
are attached.
1(P) port size
04F
06F
08F
01S
02S
03S
None
With L-bracket
ø4
ø6
ø8
R1 8
R1 4
R3 8
Knob color
2 port valve
Nil
(Standard) 3 port valve
2 port valve
R
(Option) 3 port valve
Gray
Blue
Red
2(A) port size
04F
06F
08F
01S
02S
03S
ø4
ø6
ø8
R1 8
R1 4
R3 8
Standard Type
Applicable tubing
O.D. (mm)
1(P)
Applicable tubing O.D. (mm)
ø4
ø4

ø6

ø8
ø6
ø8



2(A)
1(P): One-touch fitting
2(A): Male thread
Applicable tubing O.D. (mm)
ø4
ø6
M5


18



14


38


1(P)
Port size R
2(A)
1(P): Male thread
2(A): One-touch fitting
ø8
Port size R
2(A)
M5
18
ø4


ø6

1(P)
Applicable tubing
O.D. (mm)
1(P): One-touch fitting
2(A): One-touch fitting
ø8
14
38






∗ Specifications and dimensions for the 25A-series are the
same as standard products.
56
Fittings/Flow Air Filters/Pressure
Fluid Control Detection
Clean
Air Preparation Vacuum Air Grippers
Rotary
Equipment Switches Control Equipment Control Equipment Air Filters
Equipment Equipment
Actuators
25A VHK 2
Auto
Switches
Series
Directional
Actuators Control
Valves
Finger Valve