Series 25A-SY5000
Transcription
Series 25A-SY5000
Plug-in Connector Connecting Base Type 10 Side Ported D-sub Connector Type 11 Bottom Ported Series 25A-SY5000 How to Order Manifold 25A SS5Y 5 10 F 1 q w 05 U e r t y u RoHS C6 i o Series compatible with secondary batteries q Series 5 u SUP/EXH block assembly y P, E port entry SY5000 U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 24 stations) U D B w Type 10 11 Side ported Bottom ported Internal pilot Nil Internal pilot, Built-in silencer S ∗ 3/5(E) port is plugged for the built-in silencer type. i A, B port size (Metric) Type 10/ Type 11/ Side ported Bottom ported SY5000 SY5000 ø4 One-touch fitting C4 ø6 One-touch fitting C6 ø8 One-touch fitting C8 Straight port, mixed sizes CM∗ P, E port size (One-touch fittings) ø10 ø10 Symbol e Connector type Straight F: D-sub connector (25 pins) A, B port LOC K FRE ∗ Indicate the sizes on the manifold specification sheet in the case of “CM”. ∗ The direction of P, E port fittings is the same as for A, B port. E r Connector entry direction 1: Upward 2: Lateral LOC LOC K K FRE FRE E E t Valve stations o Mounting Symbol Mounting Nil Direct mounting D DIN rail mounting DIN rail option Standard length Nil With DIN bracket (Without DIN rail) 0 For 3 stations Specify a longer rail 3 than the total length 24 For 24 stations of specified stations. Note 1) Enter the number of stations inside . (Refer to “DIN Rail Option” above.) Note 2) Only direct mounting is available for Type 11 (Bottom ported). F: D-sub connector (25 pins) Note 1) Double wiring: 2-position single, double, 3-position and Note 1) Double wiring 4-position valves can 12 12 stations be used on all 02 2 stations Specified layout Note 2) manifold stations. (Available up to Use of a 2-position 24 solenoids) 24 24 stations single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly. Symbol Stations 02 2 stations 1 Note ∗ Specifications and dimensions for the 25A-series are the same as standard products. Series 25A-SY5000 Directional Actuators Control Valves D-sub Connector How to Order Valves (With two mounting screws) 25A SY 5 1 0 0 q w 5 e r t y 1 u i o Related Products Base mounted Series compatible with secondary batteries 5 t Pilot valve option SY5000 w Type of actuation 1 2 3 4 5 A B C 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.) e Seal type 0 Rubber seal r Back pressure check valve (Built-in valve type) Nil None H Built-in ∗ The built-in valve type back pressure check valve is not available for the 3-position type. Nil B o Manual override Standard (0.7 MPa) Quick response type (0.7 MPa) Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type F: Slide locking type y Coil type Nil Standard T With power saving circuit (Continuous duty type) ∗ Be sure to select the power saving circuit type when the valve is continuously energized for long periods of time. ∗ Note the specified energizing time when power saving circuit is selected. u Rated voltage 5 6 24 VDC 12 VDC i Light /surge voltage suppressor and common specification Without light /surge voltage suppressor (Non-polar) With surge voltage suppressor R (Non-polar) With light /surge voltage suppressor U (Non-polar) With surge voltage suppressor S (Positive common) With light /surge voltage suppressor Z (Positive common) With surge voltage suppressor NS (Negative common) With light /surge voltage suppressor NZ (Negative common) ∗ Only “Z” and “NZ” types are available for the product with power saving circuit. Nil ∗ Specifications and dimensions for the 25A-series are the same as standard products. Protective class class # (Mark: ) Auto Switches q Series Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Plug-in Connector Connecting Base 2 Plug-in Connector Connecting Base D-sub Connector Type 12 Top Ported Series 25A-SY5000 How to Order Manifold 25A SS5Y 5 12 F 1 q RoHS 05 U w e r t y u Series compatible with secondary batteries r Valve stations q Series 5 SY5000 F: D-sub connector (25 pins) Note 1) Double wiring: Symbol Stations 02 2 stations w Connector type F: D-sub connector (25 pins) LOC K FRE E e Connector entry direction 1: Upward Note 2-position single, double, 3-position Double wiring Note 1) and 4-position valves 12 12 stations can be used on all Note 2) 02 2 stations Specified layout manifold stations. (Available up to Use of a 2-position 24 solenoids) 24 24 stations single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that 2-position double, 3-position and 4- position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly. 2: Lateral t P, E port entry LOC LOC K K FRE E FRE E U Note) U side (2 to 10 stations) D Note) D side (2 to 10 stations) B Both sides (2 to 24 stations) y SUP/EXH block assembly Nil S Internal pilot Internal pilot,Built-in silencer ∗ For built-in silencer type, P and E ports are available on U and D sides. 3/5(E) port is plugged. The silencer exhaust port is located on the opposite side of P, E port entry. (Example: When the P, E port entry is D side, the silencer exhaust port is U side.) Note) y For type “S”, supply/exhaust block assembly with built-in silencer, choose U or D for P port entry. u Mounting Nil D D0 D3 Direct mounting DIN rail mounting (With DIN rail) DIN rail mounting (Without DIN rail) For 3 stations Specify a longer rail than the D24 For 24 stations standard length. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 3 25A-SY5000 Directional Actuators Control Valves Series How to Order Valves (With two mounting screws) q w 5 e r t y 1 C6 u i o !0 Related Products 25A SY 5 1 3 0 Top ported Series compatible with secondary batteries t Pilot valve option q Series 5 SY5000 w Type of actuation 1 2 3 4 5 A B C 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.) e Seal type 0 Rubber seal r Back pressure check valve (Built-in valve type) Nil None H Built-in ∗ The built-in valve type back pressure check valve is not available for the 3-position type. Nil B o Manual override Standard (0.7 MPa) Quick response type (0.7 MPa) Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type F: Slide locking type y Coil type Nil Standard T With power saving circuit (Continuous duty type) ∗ Be sure to select the power saving circuit type when the valve is continuously energized for long periods of time. ∗ Note the specified energizing time when power saving circuit is selected. u Rated voltage 5 6 24 VDC 12 VDC i Light/surge voltage suppressor and common specification Without light/surge voltage suppressor (Non-polar) With surge voltage suppressor R (Non-polar) With light/surge voltage suppressor U (Non-polar) With surge voltage suppressor S (Positive common) With light/surge voltage suppressor Z (Positive common) With surge voltage suppressor NS (Negative common) With light/surge voltage suppressor NZ (Negative common) ∗ Only “Z” and “NZ” types are available for the product with power saving circuit. Nil !0 A, B port size One-touch fitting (Metric) Symbol A, B port C4 ø4 One-touch fitting C6 ø6 One-touch fitting C8 ø8 One-touch fitting SY5000 ∗ Specifications and dimensions for the 25A-series are the same as standard products. Protective class class # (Mark: ) 4 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators D-sub Connector Auto Switches Plug-in Connector Connecting Base Plug-in Connector Connecting Base Type 10 Side Ported Terminal Block Box Type 11 Bottom Ported 25A-SY5000 Series How to Order Manifold 25A SS5Y 5 10 T q w 05 U e r t C6 y u Series compatible with secondary batteries 5 u Mounting r P, E port entry q Series SY5000 U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 20 stations) w Type Side ported Bottom ported e Valve stations Symbol Stations 02 2 stations 10 10 stations 02 2 stations Note Double wiring Note 1) Specified layout Note 2) (Available up to 20 solenoids) 20 20 stations Note 1) Double wiring: 2-position single, double, 3-position and 4-position valves can be used on all manifold stations. Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications with the manifold specification sheet. (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly. t SUP/EXH block assembly Internal pilot Nil Internal pilot, Built-in silencer S ∗ 3/5(E) port is plugged for the built-in silencer type. ∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. DIN rail option Standard length Nil With DIN bracket (Without DIN rail) 0 For 3 stations Specify a longer rail 3 than the total length of 24 For 24 stations specified stations. y A, B port size (Metric) Symbol Type 10/ Type 11/ Side ported Bottom ported A, B port ø4 One-touch fitting C4 ø6 One-touch fitting C6 ø8 One-touch fitting C8 Straight port, mixed sizes CM∗ P, E port size (One-touch fittings) Straight 10 11 Symbol Mounting Direct mounting Nil DIN rail mounting D Note 1) Enter the number of stations inside . (Refer to “DIN Rail Option” below.) Note 2) Only direct mounting is available for Type 11 (Bottom ported). SY5000 ø10 SY5000 ø10 ∗ Indicate the sizes on the manifold specification sheet in the case of “CM”. ∗ The direction of P, E port fittings is the same as for A, B port. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 5 25A-SY5000 Directional Actuators Control Valves Series How to Order Valves (With two mounting screws) 25A SY 5 1 0 0 q w 5 e r t y 1 u i o Related Products Base mounted Series compatible with secondary batteries t Pilot valve option q Series 5 SY5000 Nil B o Manual override Standard (0.7 MPa) Quick response type (0.7 MPa) w Type of actuation 1 2 3 4 5 A B C 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.) e Seal type 0 Rubber seal r Back pressure check valve (Built-in valve type) Nil None H Built-in ∗ The built-in valve type back pressure check valve is not available for the 3-position type. Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type F: Slide locking type y Coil type Nil Standard T With power saving circuit (Continuous duty type) ∗ Be sure to select the power saving circuit type when the valve is continuously energized for long periods of time. ∗ Note the specified energizing time when power saving circuit is selected. u Rated voltage 5 6 24 VDC 12 VDC i Light/surge voltage suppressor and common specification Without light/surge voltage suppressor (Non-polar) With surge voltage suppressor R (Non-polar) With light/surge voltage suppressor U (Non-polar) With surge voltage suppressor S (Positive common) With light/surge voltage suppressor Z (Positive common) With surge voltage suppressor NS (Negative common) With light/surge voltage suppressor NZ (Negative common) ∗ Only “Z” and “NZ” types are available for the product with power saving circuit. Nil ∗ Specifications and dimensions for the 25A-series are the same as standard products. Protective class class # (Mark: ) 6 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Terminal Block Box Auto Switches Plug-in Connector Connecting Base Plug-in Connector Connecting Base Terminal Block Box Type 12 Top Ported Series 25A-SY5000 How to Order Manifold 25A SS5Y 5 12T 05 U q w e r t Series compatible with secondary batteries 5 r SUP/EXH block assembly w Valve stations q Series SY5000 e P, E port entry U Note) U side (2 to 10 stations) D Note) D side (2 to 10 stations) B Both sides (2 to 20 stations) Note) r For type “S”, supply/exhaust block assembly with built-in silencer, choose U or D for P port entry. Symbol Stations 02 2 stations 10 10 stations 02 2 stations Note Double wiring Note 1) Specified layout Note 2) (Available up to 20 solenoids) 20 20 stations Note 1) Double wiring: 2-position single, double, 3-position and 4-position valves can be used on all manifold stations. Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly. Internal pilot Nil Internal pilot, Built-in silencer S ∗ For built-in silencer type, P and E ports are available on U and D sides. 3/5(E) port is plugged. The silencer exhaust port is located on the opposite side of P, E port entry. (Example: When the P, E port entry is D side, the silencer exhaust port is U side.) ∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. t Mounting Nil Direct mounting DIN rail mounting D (With DIN rail) DIN rail mounting D0 (Without DIN rail) D3 For 3 stations Specify a longer rail than the standard D20 For 20 stations length. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 7 25A-SY5000 Directional Actuators Control Valves Series How to Order Valves (With two mounting screws) q w 5 e r t y 1 C6 u i o !0 Related Products 25A SY 5 1 3 0 Top ported Series compatible with secondary batteries t Pilot valve option q Series 5 SY5000 Nil B o Manual override Standard (0.7 MPa) Quick response type (0.7 MPa) Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type F: Slide locking type w Type of actuation 1 2 3 4 5 A B C 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.) e Seal type 0 Rubber seal r Back pressure check valve (Built-in valve type) Nil None H Built-in ∗ The built-in valve type back pressure check valve is not available for the 3-position type. y Coil type Nil Standard T With power saving circuit (Continuous duty type) ∗ Be sure to select the power saving circuit type when the valve is continuously energized for long periods of time. ∗ Note the specified energizing time when power saving circuit is selected. !0 A, B port size u Rated voltage 5 6 24 VDC 12 VDC i Light /surge voltage suppressor One-touch fitting (Metric) Symbol A, B port C4 ø4 One-touch fitting C6 ø6 One-touch fitting C8 ø8 One-touch fitting SY5000 and common specification Without light /surge voltage suppressor (Non-polar) With surge voltage suppressor R (Non-polar) With light /surge voltage suppressor U (Non-polar) With surge voltage suppressor S (Positive common) With light /surge voltage suppressor Z (Positive common) With surge voltage suppressor NS (Negative common) With light /surge voltage suppressor NZ (Negative common) ∗ Only “Z” and “NZ” types are available for the product with power saving circuit. Nil ∗ Specifications and dimensions for the 25A-series are the same as standard products. Protective class class # (Mark: ) 8 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Terminal Block Box Auto Switches Plug-in Connector Connecting Base Type 10 Side Ported Type 11 Bottom Ported Plug-in Connector Connecting Base Lead Wire Series 25A-SY5000 How to Order Manifold 25A SS5Y 5 10 L1 1 q w e 05 U r t y u RoHS C6 i o Series compatible with secondary batteries 5 e Number of cores SY5000 (Lead wire) L1 L2 L3 w Type 10 11 34 cores 17 cores 9 cores r Lead wire length Side ported Bottom ported 1 2 3 Symbol Stations 02 2 stations Double wiring Note 1) 16 16 stations 02 2 stations Specified layout Note 2) (Available up to 32 solenoids) 24 24 stations Symbol Stations 02 2 stations u SUP/EXH block assembly Note i A, B port size (Metric) Double wiring Note 1) 04 4 stations 02 2 stations Specified layout Note 2) (Available up to 8 solenoids) 08 8 stations (L2) Symbol Stations 02 2 stations U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 24 stations) Internal pilot Nil Internal pilot, Built-in silencer S ∗ 3/5(E) port is plugged for the built-in silencer type. ∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. (L3) Note U D B 0.6 m 1.5 m 3m t Valve stations (L1) y P, E port entry Note Double wiring Note 1) 08 8 stations 02 2 stations Specified layout Note 2) (Available up to 16 solenoids) 16 16 stations Note 1) Double wiring: 2-position single, double, 3-position and 4-position valves can be used on all manifold stations. Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly. Type 10/ Type 11/ Side ported Bottom ported SY5000 SY5000 ø4 One-touch fitting C4 ø6 One-touch fitting C6 ø8 One-touch fitting C8 Straight port, mixed sizes CM∗ P, E port size (One-touch fittings) ø10 ø10 Symbol A, B port Straight q Series ∗ Indicate the sizes on the manifold specification sheet in the case of “CM”. ∗ The direction of P, E port fittings is the same as for A, B port. o Mounting Symbol Mounting Direct mounting Nil DIN rail mounting D Note 1) Enter the number of stations inside . (Refer to “DIN Rail Option” below.) Note 2) Only direct mounting is available for Type 11 (Bottom ported). DIN rail option Standard length Nil With DIN bracket (Without DIN rail) 0 For 3 stations Specify a longer rail than 3 the total length of specified 24 For 24 stations stations. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 9 25A-SY5000 Directional Actuators Control Valves Series How to Order Valves (With two mounting screws) 25A SY 5 1 0 0 q w 5 e r t y 1 u i o Related Products Base mounted Series compatible with secondary batteries q Series 5 t Pilot valve option SY5000 Nil B o Manual override Standard (0.7 MPa) Quick response type (0.7 MPa) w Type of actuation 1 2 3 4 5 A B C 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.) e Seal type 0 Rubber seal r Back pressure check valve Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type F: Slide locking type y Coil type Nil Standard T With power saving circuit (Continuous duty type) ∗ Be sure to select the power saving circuit type when the valve is continuously energized for long periods of time. ∗ Note the specified energizing time when power saving circuit is selected. u Rated voltage 5 6 24 VDC 12 VDC (Built-in valve type) Nil None H Built-in ∗ The built-in valve type back pressure check valve is not available for the 3-position type. i Light /surge voltage suppressor and common specification Without light /surge voltage suppressor (Non-polar) With surge voltage suppressor R (Non-polar) With light /surge voltage suppressor U (Non-polar) With surge voltage suppressor S (Positive common) With light /surge voltage suppressor Z (Positive common) With surge voltage suppressor NS (Negative common) With light /surge voltage suppressor NZ (Negative common) ∗ Only “Z” and “NZ” types are available for the product with power saving circuit. Nil ∗ Specifications and dimensions for the 25A-series are the same as standard products. 10 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Lead Wire Auto Switches Plug-in Connector Connecting Base Plug-in Connector Connecting Base Lead Wire Type 12 Top Ported Series 25A-SY5000 How to Order Manifold 25A SS5Y 5 12 L1 1 q w e RoHS 05 U r t y u Series compatible with secondary batteries t P, E port entry q Series 5 SY5000 w Number of cores (Lead wire) L1 L2 L3 34 cores 17 cores 9 cores e Lead wire length 1 2 3 0.6 m 1.5 m 3m r Valve stations (L1) Symbol Stations 02 2 stations (L3) Note Double wiring Note 1) 16 16 stations 02 2 stations Specified layout Note 2) (Available up to 32 solenoids) 24 24 stations Symbol Stations 02 2 stations Note Double wiring Note 1) 04 4 stations 02 2 stations Specified layout Note 2) (Available up to 8 solenoids) 08 8 stations y SUP/EXH block assembly Internal pilot Nil Internal pilot, Built-in silencer S ∗ For built-in silencer type, P and E ports are available on U and D sides. 3/5(E) port is plugged. The silencer exhaust port is located on the opposite side of P, E port entry. (Example: When the P, E port entry is D side, the silencer exhaust port is U side.) ∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. u Mounting Nil (L2) Symbol Stations 02 2 stations U Note) U side (2 to 10 stations) D Note) D side (2 to 10 stations) B Both sides (2 to 24 stations) Note) y For type “S”, supply/exhaust block assembly with built-in silencer, choose U or D for P port entry. Note Double wiring Note 1) 08 8 stations 02 2 stations Specified layout Note 2) (Available up to 16 solenoids) 16 16 stations Direct mounting DIN rail mounting D (With DIN rail) DIN rail mounting D0 (Without DIN rail) D3 For 3 stations Specify a longer rail than the standard D24 For 24 stations length. Note 1) Double wiring: 2-position single, double, 3-position and 4-position valves can be used on all manifold stations. Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 11 25A-SY5000 Directional Actuators Control Valves Series How to Order Valves (With two mounting screws) q w 5 e r t y 1 C6 u i o !0 Related Products 25A SY 5 1 3 0 Top ported Series compatible with secondary batteries t Pilot valve option q Series 5 SY5000 w Type of actuation 1 2 3 4 5 A B C 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.) o Manual override Standard (0.7 MPa) Quick response type (0.7 MPa) Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type F: Slide locking type y Coil type Nil Standard T With power saving circuit (Continuous duty type) ∗ Be sure to select the power saving circuit type when the valve is continuously energized for long periods of time. ∗ Note the specified energizing time when power saving circuit is selected. u Rated voltage e Seal type 0 Nil B Rubber seal 5 6 24 VDC 12 VDC !0 A, B port size One-touch fitting (Metric) r Back pressure check valve i Light /surge voltage suppressor Nil None H Built-in ∗ The built-in valve type back pressure check valve is not available for the 3-position type. Without light /surge voltage suppressor (Non-polar) With surge voltage suppressor R (Non-polar) With light /surge voltage suppressor U (Non-polar) With surge voltage suppressor S (Positive common) With light /surge voltage suppressor Z (Positive common) With surge voltage suppressor NS (Negative common) With light /surge voltage suppressor NZ (Negative common) ∗ Only “Z” and “NZ” types are available for the product with power saving circuit. (Built-in valve type) and common specification Nil Symbol A, B port C4 ø4 One-touch fitting C6 ø6 One-touch fitting C8 ø8 One-touch fitting SY5000 ∗ Specifications and dimensions for the 25A-series are the same as standard products. Protective class class # (Mark: ) 12 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Lead Wire Auto Switches Plug-in Connector Connecting Base Plug-in Connector Connecting Base Type 10 Side Ported EX260 Type 11 Bottom Ported Series 25A-SY5000 How to Order Manifold 25A SS5Y 5 10 S NA N 05 U q w e r t RoHS C6 y u i o Series compatible with secondary batteries t Valve stations q Series 5 SY5000 w Type 10 11 Side ported Bottom ported e SI unit specifications Number of Communication outputs connector Without SI unit 0 32 QA DeviceNet™ M12 16 QB 32 NA PROFIBUS M12 16 DP NB 32 DA M12 EtherCAT ® 16 DB For SI unit part number, refer to page 21. DIN rail cannot be mounted without SI unit. Symbol Protocol r SI unit output polarity Nil Positive common N Negative common Note 1) Ensure a match with the common specifications of the value to be used. Note 2) Without SI unit, the symbol is nil. In the case of the 32-output SI unit Symbol Stations Note 02 2 stations Double wiring Note 1) 16 16 stations 02 2 stations Specified layout Note 2) (Available up to 32 solenoids) 24 24 stations In the case of the 16-output SI unit Symbol Stations Note 02 2 stations Double wiring Note 1) 08 8 stations 02 2 stations Specified layout Note 2) (Available up to 16 solenoids) 16 16 stations Note 1) Double wiring: 2-position single, double, 3-position and 4-position valves can be used on all manifold stations. Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly. Note 4) For the model without the SI unit (S0), note the maximum number of solenoids of the SI unit that will be mounted. If the layout is specified, indicate it on the manifold specification sheet. y P, E port entry U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 24 stations) u SUP/EXH block assembly Nil Internal pilot Internal pilot, Built-in silencer S ∗ 3/5(E) port is plugged for the built-in silencer type. ∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. o Mounting Symbol Mounting Direct mounting Nil DIN rail mounting D Note 1) Enter the number of stations inside . (Refer to “DIN Rail Option” below.) Note 2) Only direct mounting is available for Type 11 (Bottom ported). DIN rail option Direct mounting Nil With DIN bracket (Without DIN rail) 0 For 3 stations Specify a longer rail 3 than the total length 24 For 24 stations of specified stations. ∗ When it is necessary to mount a DIN rail without an SI unit, select D0 and order DIN rail length separately, referring to L3 in the dimensions. i A, B port size (Metric) Type 10/ Type 11/ Side ported Bottom ported SY5000 SY5000 ø4 One-touch fitting C4 ø6 One-touch fitting C6 ø8 One-touch fitting C8 Straight port, mixed sizes CM∗ P, E port size (One-touch fittings) ø10 ø10 A, B port Straight Symbol ∗ Indicate the sizes on the manifold specification sheet in the case of “CM”. 13 ∗ Specifications and dimensions for the 25A-series are the same as standard products. Refer to Fieldbus System (CAT.E02-25) for details on the EX260 Integrated-type (For Output) Serial Transmission System. 25A-SY5000 Directional Actuators Control Valves Series How to Order Valves (With two mounting screws) q w 5 e r t y 1 u i o Related Products 25A SY 5 1 0 0 Base mounted Series compatible with secondary batteries 5 SY5000 w Type of actuation 1 2 3 4 5 A B C 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.) Nil B Standard (0.7 MPa) Quick response type (0.7 MPa) Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type F: Slide locking type y Coil type Nil Standard T With power saving circuit (Continuous duty type) ∗ Be sure to select the power saving circuit type when a valve is continuously energized for long periods of time. ∗ Note the specified energizing time when power saving circuit is selected. u Rated voltage e Seal type 0 o Manual override t Pilot valve option q Series 5 24 VDC Rubber seal i Light /surge voltage suppressor r Back pressure check valve (Built-in valve type) Nil None H Built-in ∗ The built-in valve type back pressure check valve is not available for the 3-position type. and common specification With surge voltage suppressor (Non-polar) With light /surge voltage suppressor U (Non-polar) With surge voltage suppressor S (Positive common) With light /surge voltage suppressor Z (Positive common) With surge voltage suppressor NS (Negative common) With light /surge voltage suppressor NZ (Negative common) ∗ Select a valve from R, U, S or Z when the SI unit output polarity is Nil (Positive common). Select a valve from R, U, NS or NZ when the SI unit output polarity is N (Negative common). ∗ Only “Z” and “NZ” types are available for the product with power saving circuit. R ∗ Specifications and dimensions for the 25A-series are the same as standard products. Protective class class # (Mark: ) 14 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators EX260 Auto Switches Plug-in Connector Connecting Base Plug-in Connector Connecting Base EX260 Type 12 Top Ported Series 25A-SY5000 How to Order Manifold RoHS 25A SS5Y 5 12S NA N 05 U q w e r t y u Series compatible with secondary batteries q Series 5 r Valve stations SY5000 w SI unit specifications Number of Communication outputs connector Without SI unit 0 32 QA DeviceNet™ M12 16 QB 32 NA PROFIBUS M12 DP 16 NB 32 DA EtherCAT ® M12 16 DB For SI unit part number, refer to page 21. DIN rail cannot be mounted without SI unit. Symbol Protocol e SI unit output polarity Nil Positive common (NPN) N Negative common (PNP) Note 1) Ensure a match with the common specifications of the value to be used. Note 2) Without SI unit, the symbol is nil. In the case of the 32-output SI unit Symbol Stations Note 02 2 stations Double wiring Note 1) 16 16 stations 02 2 stations Specified layout Note 2) (Available up to 32 solenoids) 24 24 stations In the case of the 16-output SI unit Symbol Stations Note 02 2 stations Double wiring Note 1) 08 8 stations 02 2 stations Specified layout Note 2) (Available up to 16 solenoids) 16 16 stations Note 1) Double wiring: 2-position single, double, 3-position and 4-position valves can be used on all manifold stations. Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly. Note 4) For the model without the SI unit (S0), note the maximum number of solenoids of the SI unit that will be mounted. If the layout is specified, indicate it on the manifold specification sheet. t P, E port entry U side (2 to 10 stations) U Note) D side (2 to 10 stations) D Note) Both sides (2 to 24 stations) B Note) y For type “S”, supply/exhaust block assembly with built-in silencer, choose U or D for P port entry. y SUP/EXH block assembly Internal pilot Nil Internal pilot, Built-in silencer S ∗ For built-in silencer type, P and E ports are available on U and D sides. 3/5(E) port is plugged. The silencer exhaust port is located on the opposite side of P, E port entry. (Example: When the P, E port entry is D side, the silencer exhaust port is U side.) ∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. u Mounting Nil D D0 D3 Direct mounting DIN rail mounting (With DIN rail) DIN rail mounting (Without DIN rail) For 3 stations Specify a longer rail than the D24 For 24 stations standard length. ∗ When it is necessary to mount a DIN rail without an SI unit, select D0 and order DIN rail length separately, referring to L3 in the dimensions. ∗ Specifications and dimensions for the 25A-series are the same as standard products. Refer to Fieldbus System (CAT.E02-25) for details on the EX260 Integrated-type (For Output) Serial Transmission System. 15 EX260 Series 25A-SY5000 Directional Actuators Control Valves Plug-in Connector Connecting Base How to Order Valves (With two mounting screws) 25A SY 5 1 3 0 e r t y u i o 1 C6 !0 Series compatible with secondary batteries q Series 5 y Coil type SY5000 w Type of actuation 1 2 3 4 5 A B C 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.) D: Push-turn locking slotted type u Rated voltage E: Push-turn locking lever type F: Slide locking type 5 24 VDC and common specification Rubber seal r Back pressure check valve (Built-in valve type) Nil None H Built-in ∗ The built-in valve type back pressure check valve is not available for the 3-position type. t Pilot valve option Nil B Nil: Non-locking push type i Light /surge voltage suppressor e Seal type 0 o Manual override Nil Standard T With power saving circuit (Continuous duty type) ∗ Be sure to select the power saving circuit type when a valve is continuously energized for long periods of time. ∗ Note the specified energizing time when power saving circuit is selected. Standard (0.7 MPa) Quick response type (0.7 MPa) With surge voltage suppressor (Non-polar) With light /surge voltage suppressor U (Non-polar) With surge voltage suppressor S (Positive common) With light /surge voltage suppressor Z (Positive common) With surge voltage suppressor NS (Negative common) With light /surge voltage suppressor NZ (Negative common) ∗ Select a valve from R, U, S or Z when the SI unit output polarity is Nil (Positive common). Select a valve from R, U, NS or NZ when the SI unit output polarity is N (Negative common). ∗ Only “Z” and “NZ” types are available for the product with power saving circuit. R !0 A, B port size One-touch fitting (Metric) Symbol A and B port C4 ø4 One-touch fitting C6 ø6 One-touch fitting C8 ø8 One-touch fitting SY5000 ∗ Specifications and dimensions for the 25A-series are the same as standard products. Protective class class # (Mark: ) 16 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Related Products Top ported Auto Switches q w 5 Plug-in Connector Connecting Base Type 10 Side Ported EX126 Type 11 Bottom Ported Series 25A-SY5000 How to Order Manifold 25A SS5Y 5 10 S4 V q w e 05 U r t y RoHS C6 u i Series compatible with secondary batteries q Series w Type 10 11 Side ported Bottom ported e SI unit 0 Without SI unit V CC-Link (Positive common NPN) ∗ Only a terminal block plate is mounted for the valve without SI unit. For SI unit part number, refer to page 21. r Valve stations Symbol Stations 02 2 stations 08 8 stations 02 2 stations i Mounting t P, E port entry SY5000 Note Double wiring Note 1) Specified layout Note 2) (Available up to 16 solenoids) 16 16 stations Note 1) Double wiring: 2-position single, double, 3-position and 4-position valves can be used on all manifold stations. Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications with the manifold specification sheet. (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly. U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 16 stations) y SUP/EXH block assembly Internal pilot Nil Internal pilot, Built-in silencer S ∗ 3/5(E) port is plugged for the built-in silencer type. ∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. Symbol Mounting Direct mounting Nil DIN rail mounting D Note 1) Enter the number of stations inside . (Refer to “DIN Rail Option” below.) Note 2) Only direct mounting is available for Type 11 (Bottom ported). DIN rail option Standard length Nil With DIN bracket (Without DIN rail) 0 For 3 stations Specify a longer rail 3 than the total length 16 For 16 stations of specified stations. u A, B port (Metric) Type 10/ Type 11/ Side ported Bottom ported SY5000 SY5000 ø4 One-touch fitting C4 ø6 One-touch fitting C6 ø8 One-touch fitting C8 Straight port, mixed sizes CM∗ P, E port size (One-touch fittings) ø10 ø10 Symbol A, B port Straight 5 ∗ Indicate the size on the manifold specification sheet in the case of “CM”. ∗ The direction of P, E port fittings is the same as for A, B port. ∗ Specifications and dimensions for the 25A-series are the same as standard products. Refer to Reduced Wiring Fieldbus System (Serial Transmission) in Electric Products (CAT.E150) for details on the EX126 Integrated-type (For Output) Serial Transmission System. 17 Series 25A-SY5000 Directional Actuators Control Valves EX126 How to Order Valves (With two mounting screws) 25A SY 5 1 0 0 q w 5 e r t y 1 u i o Related Products Base mounted Series compatible with secondary batteries t Pilot valve option 5 SY5000 w Type of actuation 1 2 3 4 5 A B C 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.) e Seal type 0 Rubber seal r Back pressure check valve (Built-in valve type) Nil None H Built-in ∗ The built-in valve type back pressure check valve is not available for the 3-position type. Nil B o Manual override Standard (0.7 MPa) Quick response type (0.7 MPa) Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type F: Slide locking type y Coil type Nil Standard T With power saving circuit (Continuous duty type) ∗ Be sure to select the power saving circuit type when the valve is continuously energized for long periods of time. ∗ Note the specified energizing time when power saving circuit is selected. u Rated voltage 5 24 VDC i Light /surge voltage suppressor and common specification With surge voltage suppressor (Non-polar) With light /surge voltage suppressor U (Non-polar) With surge voltage suppressor S (Positive common) With light /surge voltage suppressor Z (Positive common) ∗ Only “Z” type is available for the product with power saving circuit. R ∗ Specifications and dimensions for the 25A-series are the same as standard products. Auto Switches q Series Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Plug-in Connector Connecting Base 18 Plug-in Connector Connecting Base EX126 Type 12 Top Ported Series 25A-SY5000 How to Order Manifold 25A SS5Y 5 12S4 V q w RoHS 05 U e r t y Series compatible with secondary batteries e Valve stations q Series 5 SY5000 w SI unit 0 Without SI unit V CC-Link (Positive common NPN) ∗ Only a terminal block plate is mounted for the valve without SI unit. For SI unit part number, refer to page 21. Symbol Stations 02 2 stations 08 8 stations 02 2 stations r P, E port entry Note Double wiring Note 1) Specified layout Note 2) (Available up to 16 solenoids) 16 16 stations Note 1) Double wiring: 2-position single, double, 3- position and 4-position valves can be used on all manifold stations. Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly. U Note) U side (2 to 10 stations) D Note) D side (2 to 10 stations) B Both sides (2 to 16 stations) Note) t For type “S”, supply/exhaust block assembly with built-in silencer, choose U or D for P port entry. t SUP/EXH block assembly Internal pilot Nil Internal pilot, Built-in silencer S ∗ For built-in silencer type, P and E ports are available on U and D sides. 3/5(E) port is plugged. The silencer exhaust port is located on the opposite side of P, E port entry. (Example: When the P, E port entry is D side, the silencer exhaust port is U side.) ∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. y Mounting Nil D D0 D3 Direct mounting DIN rail mounting (With DIN rail) DIN rail mounting (Without DIN rail) For 3 stations Specify a longer rail than the D16 For 16 stations standard length. ∗ Specifications and dimensions for the 25A-series are the same as standard products. Refer to Reduced Wiring Fieldbus System (Serial Transmission) in Electric Products (CAT.E150) for details on the EX126 Integrated-type (For Output) Serial Transmission System. 19 25A-SY5000 Directional Actuators Control Valves Series How to Order Valves (With two mounting screws) q w 5 e r t y 1 C6 u i o !0 Related Products 25A SY 5 1 3 0 Top ported Series compatible with secondary batteries q Series t Pilot valve option 5 SY5000 w Type of actuation 1 2 3 4 5 A B C 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.) e Seal type 0 Rubber seal r Back pressure check valve (Built-in valve type) Nil None H Built-in ∗ The built-in valve type back pressure check valve is not available for the 3-position type. Nil B o Manual override Standard (0.7 MPa) Quick response type (0.7 MPa) Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type F: Slide locking type y Coil type Nil Standard T With power saving circuit (Continuous duty type) ∗ Be sure to select the power saving circuit type when the valve is continuously energized for long periods of time. ∗ Note the specified energizing time when power saving circuit is selected. u Rated voltage 5 24 VDC i Light /surge voltage suppressor and common specification With surge voltage suppressor (Non-polar) With light /surge voltage suppressor U (Non-polar) With surge voltage suppressor S (Positive common) With light /surge voltage suppressor Z (Positive common) ∗ Only “Z” types are available for models with a power saving circuit. R !0 A, B port size One-touch fitting (Metric) Symbol A, B port C4 ø4 One-touch fitting C6 ø6 One-touch fitting C8 ø8 One-touch fitting SY5000 ∗ Specifications and dimensions for the 25A-series are the same as standard products. Caution Tightening torque for mounting screw M3: 0.8 N·m Manifold Options Blanking plate assembly (With two mounting screws) Used when valve additions are expected or for maintenance. A structure is in place on the blanking plate to prevent the mounting screws from sliding. Mounting screw How to Order Blanking Plate Assembly 25A SY 5 0M 26 1 A Series 5 SY5000 Base type 1 25A-SY50M-26-1A For plug-in connector connecting base ∗ Specifications and dimensions for the 25A-series are the same as standard products. 20 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators EX126 Auto Switches Plug-in Connector Connecting Base Series 25A-SY5000 SI Unit Part No. Part no. 25A-SS5Y5 EX260-SPR1-X117 EX260-SPR2-X117 EX260-SPR3-X117 EX260-SPR4-X117 EX260-SDN1-X117 EX260-SDN2-X117 EX260-SDN3-X117 EX260-SDN4-X117 EX260-SEC1-X117 EX260-SEC2-X117 EX260-SEC3-X117 EX260-SEC4-X117 EX126D-SMJ1-X220 Description EX260 SI unit EX126 SI unit Note PROFIBUS M12 connector, 32 outputs (Negative common) (PNP) PROFIBUS M12 connector, 32 outputs (Positive common) (NPN) PROFIBUS M12 connector, 16 outputs (Negative common) (PNP) PROFIBUS M12 connector, 16 outputs (Positive common) (NPN) DeviceNet™ M12 connector, 32 outputs (Negative common) (PNP) DeviceNet™ M12 connector, 32 outputs (Positive common) (NPN) DeviceNet™ M12 connector, 16 outputs (Negative common) (PNP) DeviceNet™ M12 connector, 16 outputs (Positive common) (NPN) EtherCAT® M12 connector, 32 outputs (Negative common) (PNP) EtherCAT® M12 connector, 32 outputs (Positive common) (NPN) EtherCAT® M12 connector, 16 outputs (Negative common) (PNP) EtherCAT® M12 connector, 16 outputs (Positive common) (NPN) CC-Link (Terminal block, 16 outputs, Positive common (NPN)) Valve Mounting Screw Part No. Description Round head combination screw Part no. 25A-SS5Y5 SY5000-223-1A Note Part numbers shown on the left are for 10 valves. (20 pcs.) One-touch Fittings Part No. SY5000 Port size A, B port Metric size P, E port Metric size 21 ø4 One-touch fitting (Straight type) ø6 One-touch fitting (Straight type) ø8 One-touch fitting (Straight type) ø10 One-touch fitting (Straight type) 90-VVQ1000-51A-C4 90-VVQ1000-51A-C6 90-VVQ1000-51A-C8 90-VVQ2000-51A-C10 Series 25A-SY5000/7000 How to Order Series compatible with secondary batteries A, B port size Series 5 7 Coil specifications SY5000 SY7000 Standard With power saving circuit T (24, 12 VDC only) ∗ Power saving circuit is not available in the case of D, Y or W type. Nil Type of actuation 1 2 3 4 5 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center For DC 5 24 VDC 6 12 VDC V 6 VDC S 5 VDC R 3 VDC Manual override Electrical entry G: With lead wire L: With lead wire M: With lead wire MN: Without D,Y: With connector (Length 300 mm) (Length 300 mm) (Length 300 mm) lead wire H: With lead wire LN: Without LO: Without (Length 600 mm) lead wire connector D: Push-turn locking E: Push-turn locking slotted type lever type Rated voltage 12 VDC/ 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 100, 110, 200, 220 VAC Grommet L plug connector M plug connector DIN terminal Thread piping Symbol Port size Applicable series Rc 1 8 SY5000 01 SY7000 Rc 1 4 02 One-touch fitting (Metric size) Symbol Port size Applicable series C4 One-touch fitting for ø4 SY5000 C6 One-touch fitting for ø6 C8 One-touch fitting for ø8 C8 One-touch fitting for ø8 SY7000 C10 One-touch fitting for ø10 Nil: Non-locking push type For AC ( 50 60 Hz) 100 VAC 1 200 VAC 2 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] ∗ DC specifications of type D and Y is only available with 12 and 24 VDC. 01 Related Products L MO: Without connector ∗ LN, MN type: with 2 sockets. ∗ “Y” type is a DIN terminal conforming to EN-175301-803C (former DIN43650C). ∗ Refer to the standard products for the lead wire length of L and M plug connectors and the connector assembly with cover for L and M plug connector. Light /surge voltage suppressor Electrical entry for G, H, L, M Electrical entry for D, Y Without light /surge Without light /surge Nil Nil voltage suppressor voltage suppressor With surge With surge S S voltage suppressor voltage suppressor With light /surge With light /surge Z Z voltage suppressor voltage suppressor With surge voltage suppressor ∗ For AC voltage valves there R (Non-polar type) is no “S” option. It is already With light /surge voltage suppressor built-in to the rectifier circuit. U (Non-polar type) ∗ For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit. ∗ For “R” and “U”, DC voltage is only available. ∗ Power saving circuit is only available in the "Z" type. Note) When placing an order for body ported solenoid valve as a single unit, mounting screw for manifold and gasket are not attached. Order them separately, if necessary. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 22 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators 5 Auto Switches SY 5 1 20 25A Directional Actuators Control Valves 5 Port Solenoid Valve Body Ported/Single Unit 5 Port Solenoid Valve Base Mounted/Single Unit Series 25A-SY5000/7000 How to Order 25A SY 5 2 40 5 L Port size Symbol Nil Series compatible with secondary batteries 02 03 Port size Applicable series Without sub-plate Rc 1 4 SY5000 With sub-plate SY7000 Rc 3 8 SY7000 With sub-plate SY9000 Series 5 7 SY5000 SY7000 Manual override Nil: Non-locking D: Push-turn locking E: Push-turn locking push type slotted type lever type Type of actuation 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 1 2 3 4 5 Light /surge voltage suppressor Pilot type Nil R Internal pilot External pilot Coil specifications Nil T Standard With power saving circuit (24, 12 VDC only) ∗ Power saving circuit is not available in the case of D or Y type. Rated voltage 5 6 V S R For DC 24 VDC 12 VDC 6 VDC 6 VDC 3 VDC For AC ( 50 60 Hz) 100 VAC 1 200 VAC 2 110 VAC [115 VAC] 3 220 VAC [230 VAC] 4 ∗ DC specifications of type D and Y is only available with 12 and 24 VDC. Electrical entry for G, H, L, M Electrical entry for D, Y Nil Without light /surge voltage suppressor Nil Without light /surge voltage suppressor With surge voltage suppressor S S With surge voltage suppressor (Non-polar type) Z With light /surge voltage suppressor Z With light/surge voltage suppressor (Non-polar type) R With surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there is no “S” U With light/surge voltage suppressor (Non-polar type) option. It is already built-in to the rectifier circuit. ∗ For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit. ∗ For “R” and “U”, DC voltage is only available. ∗ Power saving circuit is only available in the "Z" type. Electrical entry 24, 12, 6, 5, 3 VDC / 100, 110, 200, 220 VAC Grommet L plug connector M plug connector 24, 12 VDC / 100, 110, 200, 220 VAC DIN terminal G: With lead wire L: With lead wire M: With lead wire MN: Without D,Y: With connector (Length 300 mm) (Length 300 mm) (Length 300 mm) lead wire +- +- –+ -+ H: With lead wire LN: Without (Length 600 mm) lead wire –+ LO: Without MO: Without connector connector -+ ∗ LN, MN type: with 2 sockets. ∗ “Y” type is a DIN terminal conforming to EN-175301-803C (former DIN43650C). ∗ Refer to the standard products for the lead wire length of L and M plug connectors and the connector assembly with cover for L and M plug connector. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 23 20 Series 25A-SY5000/7000 How to Order Manifold 20 05 Related Products Series compatible with secondary batteries Manifold series 5 7 SY5000 SY7000 Stations 02 2 stations … 20 20 stations ∗ This also includes the number of blanking plate assemblies. ∗ Specifications and dimensions for the 25A-series are the same as standard products. Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators 25A SS5Y 5 Auto Switches Type Directional Actuators Control Valves 5 Port Solenoid Valve Body Ported Manifold Bar Stock Type/Individual Wiring 24 Series 25A-SY5000/7000 How to Order Valve 25A SY 5 1 20 5 L 01 Series compatible with secondary batteries A, B port size Thread piping Symbol Port size Rc 1 8 01 Rc 1 4 02 One-touch fitting (Metric size) Symbol Port size Applicable series C4 One-touch fitting for ø4 C6 One-touch fitting for ø6 SY5000 C8 One-touch fitting for ø8 C8 One-touch fitting for ø8 SY7000 C10 One-touch fitting for ø10 Series 5 7 SY5000 SY7000 Type of actuation 1 2 3 4 5 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center Manual override Nil D E Coil specifications Nil T Standard With power saving circuit (24 VDC, 12 VDC only) ∗ Power saving circuit is not available in the case of D or Y type. Rated voltage For DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC Applicable series SY5000 SY7000 For AC ( 50 60 Hz) 1 100 VAC 2 200 VAC 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] ∗ DC specifications of type D and Y is only available with 12 and 24 VDC. Non-locking push type Push-turn locking slotted type Push-turn locking lever type Light /surge voltage suppressor Electrical entry for G, H, L, M Without light /surge voltage suppressor Nil With surge voltage suppressor S With light /surge voltage suppressor Z With surge voltage suppressor (Non-polar type) R U With light /surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit. ∗ For “R” and “U”, DC voltage is only available. ∗ Power saving circuit is only available in the “Z” type. Electrical entry for D, Y Without light /surge voltage suppressor Nil With surge voltage suppressor (Non-polar type) S Z With light /surge voltage suppressor (Non-polar type) ∗ For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit. Electrical entry 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC Grommet L plug connector M plug connector G: With lead wire L: With lead wire M: With lead wire (Length 300 mm) (Length 300 mm) (Length 300 mm) H: With lead wire LN: Without lead wire MN: Without lead wire (Length 600 mm) LO: Without connector MO: Without connector 24, 12 VDC/ 100, 110, 200, 220 VAC DIN terminal D: With connector Y: With connector ∗ LN, MN type: with 2 sockets. ∗ “Y” type is a DIN terminal conforming to EN-175301-803C (former DIN43650C). ∗ Refer to the standard products for the lead wire length of L and M plug connectors and the connector assembly with cover for L and M plug connector. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 25 How to Order Manifold 25A SS5Y 5 41 05 Related Products Type 41/Compact style C8 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Series compatible with secondary batteries Manifold series 5 SY5000 Stations 02 2 stations 20 20 stations ∗ This also includes the number of blanking plate assemblies. A, B port size Thread piping Symbol Port size 01 Rc 1 8 Applicable series SY5000 One-touch fitting (Metric size) One-touch fitting (Inch size) Symbol Port size Applicable series Symbol Port size Applicable series C6 One-touch fitting for ø6 N7 One-touch fitting for ø 1 4" SY5000 SY5000 C8 One-touch fitting for ø8 N9 One-touch fitting for ø 5 16" Type 42/External pilot capable 25A SS5Y 5 42 05 C8 Series compatible with secondary batteries Manifold series 5 7 SY5000 SY7000 A, B port size Stations 02 2 stations 20 20 stations ∗ This also includes the number of blanking plate assemblies. Directional Actuators Control Valves Type 41 42 Series 25A-SY5000/7000 Thread piping Port size Symbol Rc 1 4 02 Rc 1 4 02 Applicable series SY5000 SY7000 One-touch fitting (Inch size) One-touch fitting (Metric size) Symbol Port size Applicable series Symbol Port size Applicable series N7 One-touch fitting for ø 1 4" C6 One-touch fitting for ø6 SY5000 SY5000 N9 One-touch fitting for ø 5 16" C8 One-touch fitting for ø8 3 " N11 One-touch fitting for ø 8 C10 One-touch fitting for ø10 SY7000 SY7000 ∗ Specifications and dimensions for the 25A-series are the same as standard products. 26 Auto Switches Type 5 Port Solenoid Valve Base Mounted Manifold Bar Stock Type/Individual Wiring Series 25A-SY5000/7000 How to Order Valve SY 5 2 40 25A 5 L Series compatible with secondary batteries Series 5 7 SY5000 SY7000 Type of actuation 1 2 3 4 5 Manual override 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center Nil D E Light /surge voltage suppressor Pilot type Nil R Electrical entry for G, H, L, M Without light /surge voltage suppressor Nil With surge voltage suppressor S With light /surge voltage suppressor Z With surge voltage suppressor (Non-polar type) R U With light /surge voltage suppressor (Non-polar type) Internal pilot External pilot Coil specifications Nil T Non-locking push type Push-turn locking slotted type Push-turn locking lever type Standard With power saving circuit (24 VDC, 12 VDC only) ∗ For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit. ∗ For “R” and “U”, DC voltage is only available. ∗ Power saving circuit is only available in the “Z” type. ∗ Power saving circuit is not available in the case of D or Y type. Electrical entry for D, Y Without light /surge voltage suppressor Nil With surge voltage suppressor (Non-polar type) S Z With light /surge voltage suppressor (Non-polar type) Rated voltage For DC 24 VDC 5 12 VDC 6 6 VDC V 5 VDC S 3 VDC R For AC ( 50 60 Hz) 100 VAC 1 200 VAC 2 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] ∗ For AC voltage valves there is no “S” option. It is already built-in to the rectifier circuit. ∗ DC specifications of Type D and Y is only available with 12 and 24 VDC. Electrical entry 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC Grommet L plug connector M plug connector G: With lead wire L: With lead wire M: With lead wire (Length 300 mm) (Length 300 mm) (Length 300 mm) H: With lead wire LN: Without lead wire MN: Without lead wire (Length 600 mm) LO: Without connector MO: Without connector 24, 12 VDC/ 100, 110, 200, 220 VAC DIN terminal D: With connector Y: With connector ∗ LN, MN type: with 2 sockets. ∗ “Y” type is a DIN terminal conforming to EN-175301-803C (former DIN43650C). ∗ Refer to the standard products for the lead wire length of L and M plug connectors and the connector assembly with cover for L and M plug connector. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 27 5 Port Solenoid Valve Series 25A-SY5000/7000 25A-SY5000 Port size Cylinder port Metric size ø4 One-touch fitting (Straight type) ø6 One-touch fitting (Straight type) ø8 One-touch fitting (Straight type) ø10 One-touch fitting (Straight type) Directional Actuators Control Valves One-touch Fittings Part No. for Body Ported 25A-SY7000 90-VVQ1000-51A-C4 90-VVQ1000-51A-C6 90-VVQ1000-51A-C8 90-VVQ2000-51A-C8 90-VVQ2000-51A-C10 Gasket Assembly Part No. 25A-SY5000 Manifold type Body ported Base mounted Type 20 Type 41/42 25A-SY7000 SY7000-GS-3 SY7000-GS-4 SY5000-GS-3 SY5000-GS-4 Related Products Valve model ∗ The gasket assembly includes 10 sets of a gasket and mounting screws. Blanking plate assembly Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Manifold Options How to Order (Mounting screw: 2 pcs., with gasket) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. 25A SY 5 000 26 1A Series 5 7 Tightening torque: 0.8 N·m Round head combination screw 25A-SY5000 25A-SY7000 Blanking plate Manifold gasket Dimensions Manifold type/For type 20 Manifold type/For type 41/42 W1 EB B B EA B W B −+ −+ EB A H2 A H1 −+ H1 −+ P W2 EA A A A A A A P B H2 Dimensions Series 25A-SY5000 25A-SY7000 (mm) Manifold type W1 W2 H1 H2 Type 20 33.3 69.6 44.5 15.2 Type 20 39.4 76.4 41.1 18.3 B Dimensions Series 25A-SY5000 25A-SY7000 (mm) Manifold type W Type 41 106.4 51 21.7 Type 42 107.6 56 26.7 Type 42 118.1 55.6 32.8 H1 H2 Auto Switches B 28 A Plug-in Unit/Base Mounted F Kit (D-sub connector kit) 25A-VQ2000 Series Note) For CE compliant models, DC-type only. How to Order Manifold 25A VV5Q 2 1 08 C6 F VQ2000 Stations Plug-in unit … 02 2 stations … 24 24 stations Cylinder port Port size Symbol With ø4 One-touch fitting C4 With ø6 One-touch fitting C6 With ø8 One-touch fitting C8 Connector entry direction Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note 3) The number of stations that may be displayed is longer than the manifold number of stations. Note 4) Specify the wiring specifications by means of the manifold specification sheet. Note 5) Indicate “R” for the valve with external pilot. Top entry Side entry U S Cable (Length) Without cable With cable (1.5 m) With cable (3 m) With cable (5 m) 0 1 2 3 Note) For CE compliant models, DC-type only. How to Order Valves 25A VQ 2 1 0 1 5 CE compliant Nil Q Series 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual port (N.C./N.C.) 4-position dual port (N.O./N.O.) 4-position dual port (N.C./N.O.) 1 Manual override Rubber seal Symbol Specifications B N R DC (0.4 W) High-speed (0.95 W) response type Negative common AC Standard External pilot Use the standard (DC) specification when continuously energizing for long periods of time. 29 Nil E — Non-locking push type (Tool required) Locking type (Tool required) Locking type (Manual) Slide locking type (Manual) Light/surge voltage suppressor — Note) When two or more symbols are specified, indicate them alphabetically. Caution Nil B C D Function Nil — CE compliant Note) For CE compliant models, DC-type only. Seal VQ2000 Type of actuation 1 2 3 4 5 A B C [Option] 1 Series compatible with secondary batteries 2 — CE compliant Note) For CE compliant models, DC-type only. Option Manifold 1 Nil Q Symbol Option Nil None 2 200/220 VAC models B Note 2) With back pressure check valve D DIN rail mounting D0 With DIN rail bracket (Without DIN rail) D Note 3) DIN rail length specified (: Stations 02 to 24) K Note 4) Special wiring specifications (Except double wiring) N With name plate R Note 5) External pilot S Direct EXH outlet with built-in silencer Series 2 CE compliant U 1 Series compatible with secondary batteries [Option] Yes None Coil voltage 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC CE compliant — — — — ∗ Specifications and dimensions for the 25A-series are the same as standard products. 25A-VQ2000 08 C6 T0 CE compliant Series compatible with secondary batteries Nil Q Series 2 Symbol Nil B Note 2) D Manifold 1 Plug-in unit Stations … 02 2 stations … 20 20 stations D0 D Note 5) K Note 5) Cylinder port Symbol Port size C4 With ø4 One-touch fitting C6 With ø6 One-touch fitting C8 With ø8 One-touch fitting N R Note 6) S W — CE compliant Note) For CE compliant models, DC-type only. Option VQ2000 Option None With back pressure check valve DIN rail mounting With DIN rail bracket (Without DIN rail) DIN rail length specified (: Stations 02 to 24) Special wiring spec. (Except double wiring) With name plate External pilot Direct EXH outlet with built-in silencer Enclosure: Dust-tight, Water-jets-proof (IP65) 25A VQ 2 1 0 1 2 Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note 3) The number of stations that may be displayed is longer than the manifold number of stations. Note 4) Specify the mounting position by means of the manifold specification sheet. Note 5) Specify the wiring specifications by means of the manifold specification sheet. Note 6) Indicate “R” for the valve with external pilot. Note) For CE compliant models, DC-type only. How to Order Valves Series compatible with secondary batteries CE compliant Series Nil Q VQ2000 Enclosure Nil W Rubber seal Function Symbol Specifications B N Caution Use the standard (DC) specification when continuously energizing for long periods of time. R Dustproof Dust-tight / Water-jets-proof type (IP65) Manual override Nil B C D Seal 1 — CE compliant Note) For CE compliant models, DC-type only. 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual port (N.C./N.C.) 4-position dual port (N.O./N.O.) 4-position dual port (N.C./N.O.) Nil [Option] 1 5 Type of actuation 1 2 3 4 5 A B C Related Products 25A VV5Q 2 1 [Option] DC (0.4 W) Standard High-speed (0.95 W) response type Negative common External pilot AC — — Note) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible. Non-locking push type (Tool required) Locking type (Tool required) Locking type (Manual) Slide locking type (Manual) Light/surge voltage suppressor Nil E Yes None Coil voltage 1 100 VAC (50/60 Hz) 3 110 VAC (50/60 Hz) 5 24 VDC 6 12 VDC CE compliant — — ∗ Specifications and dimensions for the 25A-series are the same as standard products. 30 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Note) For CE compliant models, DC-type only. How to Order Manifold Auto Switches Series Directional Actuators Control Valves Plug-in Unit/Base Mounted T Kit (Terminal block box kit) Plug-in Unit/Base Mounted L Kit (Lead wire) Series 25A-VQ2000 Note) For CE compliant models, DC-type only. How to Order Manifold 25A VV5Q 2 1 06 C6 0 Cable length 0.6 m 1 Cable length 1.5 m 2 Cable length 3 m Series Manifold 1 station … 08 8 stations Note) For CE compliant models, DC-type only. Symbol Option Nil None 2 200/220 VAC models B Note 2) With back pressure check valve D DIN rail mounting D0 With DIN rail bracket (Without DIN rail) DIN rail length specified D Note 3) (: Stations 02 to 08) N With name plate R Note 4) External pilot S Direct EXH outlet with built-in silencer Enclosure: Dust-tight, W Water-jets-proof (IP65) Stations 01 Cylinder port Symbol Port size C4 With ø4 One-touch fitting C6 With ø6 One-touch fitting C8 With ø8 One-touch fitting 25A VQ 2 1 0 1 Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note 3) The number of stations that may be displayed is longer than the manifold a number of stations. Note 4) Indicate “R” for the valve with external pilot. Note) For CE compliant models, DC-type only. How to Order Valves Series compatible with secondary batteries — CE compliant Option Plug-in unit … Nil Q Cable (Length) VQ2000 1 1 CE compliant Series compatible with secondary batteries 2 L CE compliant Series 2 Nil Q VQ2000 Enclosure Nil W Rubber seal Function Symbol Specifications B N R DC (0.4 W) Standard High-speed (0.95 W) response type Negative common External pilot Nil E Yes None — Coil voltage — 1 2 3 4 5 6 Non-locking push type (Tool required) Locking type (Tool required) Locking type (Manual) Slide locking type (Manual) Light/surge voltage suppressor AC Note) When two or more symbols are specified, indicate them alphabetically. 31 Dustproof Dust-tight / Water-jets-proof type (IP65) Manual override Nil B C D Seal 1 — CE compliant Note) For CE compliant models, DC-type only. 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual port (N.C./N.C.) 4-position dual port (N.O./N.O.) 4-position dual port (N.C./N.O.) Nil [Option] 1 5 Type of actuation 1 2 3 4 5 A B C [Option] 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC CE compliant — — — — ∗ Specifications and dimensions for the 25A-series are the same as standard products. 25A-VQ2000 How to Order Manifold 08 C6 SV CE compliant Series compatible with secondary batteries Nil Q VQ2000 Manifold 1 Option Plug-in unit Symbol Option Nil None B Note 2) With back pressure check valve D DIN rail mounting DIN rail length specified D Note 3) (: Stations 02 to 16) Special wiring specifications K Note 4) (Except double wiring) N With name plate R Note 5) With external pilot Direct EXH outlet S with built-in silencer Enclosure: Dust-tight, W Note 6) Water-jets-proof (IP65) Stations 02 2 stations … 16 Note) 16 stations … — CE compliant ∗ Refer to “SI Unit Part No.” when ordering the CE-compliant SI unit. Series 2 Note) Max. 16 stations. (Specify a model with 9 to 16 stations by means of the manifold specification sheet.) Cylinder port Port size Symbol C4 With ø4 One-touch fitting C6 With ø6 One-touch fitting C8 With ø8 One-touch fitting Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS. Note 2) Models with a suffix “-B” have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet. Note 3) The number of stations that may be displayed is longer than the manifold number of stations. Note 4) Specify the wiring specifications by means of the manifold specification sheet. Note 5) Indicate “R” for the valve with external pilot. Note 6) Refer to “Dimensions” of the standard products for SI unit and valve, in case of W (Dust-tight, Water-jet-proof). SI Unit Part No. SI Unit Part No. (With option W) Symbol Protocol SI unit part no. Q DeviceNet™ EX120-SDN1-X220 V EX120-SMJ1-X220 CC-Link Symbol Protocol SI unit part no. Q DeviceNet™ EX124D-SDN1-X220 V EX124D-SMJ1-X220 CC-Link SI unit specifications Symbol Stations Protocol — 0 Without SI unit Q DeviceNet™ System Max.16 V stations CC-Link How to Order Valves 25A VQ 2 1 0 1 5 CE compliant Nil Q VQ2000 Series compatible with secondary batteries 2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual port (N.C./N.C.) 4-position dual port (N.O./N.O.) 4-position dual port (N.C./N.O.) Seal 1 — CE compliant Manual override Nil B C D Type of actuation 1 2 3 4 5 A B C [Option] 1 Series 2 Related Products 25A VV5Q 2 1 [Option] Rubber seal Non-locking push type (Tool required) Locking type (Tool required) Locking type (Manual) Slide locking type (Manual) Enclosure Nil W Dustproof Dust-tight / Water-jets-proof type (IP65) Coil voltage Function 24 VDC; With indicator light / 5 DC surge voltage suppressor (0.4 W) Standard High-speed (0.95 W) response type Negative Note 1) External pilot and negative common specifications common are the same as standard products. External Note 2) When two or more symbols are specified, indicate pilot them alphabetically. Symbol Specifications Nil B N Note 1) R Note 1) ∗ Specifications and dimensions for the 25A-series are the same as standard products. 32 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Note) Refer to “SI Unit Part No.” when ordering the CE-compliant SI unit. Auto Switches Series Directional Actuators Control Valves Plug-in Unit/Base Mounted S Kit (Serial transmission) Sub-plate Single Unit 25A-VQ2000 Series Note) For CE compliant models, [Option] DC-type only. How to Order In the case of Valve + Sub-plate 25A VQ2 1 0 1 5 W 1 02 CE compliant Series compatible with secondary batteries Nil Q Entry is the same as standard products. Note) For CE compliant models, DC-type only. Enclosure Nil W Note 1) Thread type Dustproof Dust-tight/Water-jets-proof type (IP65) Nil N T F Note 1) Valves are IP65 specifications. Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC. Sub-plate Rc NPT NPTF G Port size 02 In the case of — CE compliant 1/4 alone 25A VQ2000 PW 02 Manifold Optional Parts Blanking plate assembly 25A-VVQ2000V-10A-1 It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 33 Sub-plate Single Unit Series 25A-VQ2000 Blanking plate assembly 25A-VVQ4000-10A-1 (Plug-in type) 25A-VVQ4000-10A-5 (Plug lead type) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. ∗ Specifications and dimensions for the 25A-series are the same as standard products. Description EX124 SI unit EX120 SI unit Part no. 25A-VV5Q2/4 EX124D-SMJ1-X220 EX124D-SDN1-X220 EX120-SMJ1-X220 EX120-SDN1-X220 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators SI Unit Part No. Note CC-Link DeviceNet™ CC-Link (VQ2000/Without option W) DeviceNet™ (VQ2000/Without option W) One-touch Fittings Part No. Cylinder port Metric size 1(P), 3(R) port Metric size ø4 One-touch fitting (Straight type) ø6 One-touch fitting (Straight type) ø8 One-touch fitting (Straight type) ø10 One-touch fitting (Straight type) ø12 One-touch fitting (Straight type) ø10 One-touch fitting (Straight type) 25A-VQ2000 90-VVQ1000-51A-C4 90-VVQ1000-51A-C6 90-VVQ1000-51A-C8 90-VVQ2000-51A-C10 Auto Switches Port size Related Products Directional Actuators Control Valves Manifold Optional Parts 34 Plug-in/Plug Lead: Single Unit Base Mounted Series 25A-VQ4000 How to Order Valves [Option] Port size Body Nil 0: Plug-in sub-plate 02 03 Porting specifications Nil B Plug-in 25A VQ4 1 0 1 Plug lead 25A VQ4 2 5 1 Type of actuation 1 2 3 4 5 6 Note) 2 position single Rubber/2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 position double check Note) Thread standard is the same as standard products. Enclosure CE compliant Nil — Nil Q CE compliant W Dustproof Dust-tight / Water-jets-proof type (IP65) Manual override Nil: Non-locking push type (Tool required) Note) For double check style, refer to Best Pneumatics No. 1. Body B: Slotted locking type (Tool required) Seal 5: Plug lead sub-plate 1 Rubber seal Light/Surge voltage suppressor Function Nil Y (1) R (2) Nil E Standard type (1 W) Low wattage type (0.5 W) External pilot Note 1) Applicable to DC specifications. Please select when you expect to energize the unit for extended periods of time. Note 2) External pilot specifications are the same as standard products. Combination of external pilot and perfect interface is not possible. Note 3) When two or more symbols are specified, indicate them alphabetically. Yes Without light, with surge voltage suppressor Electrical entry Coil voltage 1 2 3 4 5 6 G 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Grommet Series compatible with secondary batteries Side ported Bottom ported Without sub-plate (For manifold) Rc 1/4 Rc 3/8 Lead wire length 0.6 m H Lead wire length 1.5 m How to Order Sub-plates [Option] CE compliant 25A VQ4000 Series compatible with secondary batteries Electrical entry P S Plug-in conduit terminal Plug lead Enclosure Dustproof Nil W Note) Dust-tight/Water-jets-proof type (IP65) Note) It is not necessary for plug lead type. 35 Nil Q Porting specifications Nil B — CE compliant Note 1) For bottom ported port Side ported size is RC 1/4 only. Bottom ported (1) Port size 02 03 Rc1/4 Rc3/8 Note 2) Thread standard is the same as standard products. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 25A-VQ4000 08 C8 F U 1 Series compatible with secondary batteries Series 4 CE compliant Nil Q Symbol Nil Manifold Plug-in unit K (1) Stations … 01 18 Cylinder port 1 station … Option None Special wiring specifications (Except double wiring) Note 1) Specify the wiring specifications on the manifold specification sheet. Note 2) Refer to the standard products for with control unit. C8 With One-touch fitting for ø8 C10 With One-touch fitting for ø10 C12 With One-touch fitting for ø12 Rc 1/4 02 Rc 3/8 03 Bottom ported Rc 1/4 B Mixed CM 18 stations — CE compliant Option VQ4000 1 Cable (Length) 0 1 2 3 Note) As an option, the maximum number of stations can be increased by special wiring specifications. Without cable Cable length 1.5 m Cable length 3 m Cable length 5 m Connector entry direction D U D side entry U side entry How to Order Valves 25A VQ 4 1 0 1 [Option] 5 Series compatible with secondary batteries Series 4 CE compliant Nil Q VQ4000 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 position double check Rubber seal Non-locking push type (Tool required) Locking type (Tool required) Light /Surge voltage suppressor Nil E Yes Without light, with surge voltage suppressor Coil voltage Seal 1 — CE compliant Manual override Nil B Type of actuation 1 2 3 4 5 6 Related Products 25A VV5Q 4 1 [Option] Function Standard type (1 W) Nil Y (1) Low wattage type (0.5 W) External pilot R (2) Note 1) Applicable to DC specifications. Please select when you expect to energize the unit for extended periods of time. Note 2) External pilot specifications are the same as standard products. Combination of external pilot and perfect interface is not possible. Note 3) When two or more symbols are specified, indicate them alphabetically. 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC ∗ Specifications and dimensions for the 25A-series are the same as standard products. 36 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators How to Order Manifold Auto Switches Series Directional Actuators Control Valves Plug-in Unit/Base Mounted F Kit (D-sub connector kit) Plug-in Unit/Base Mounted T Kit (Terminal block box kit) Series 25A-VQ4000 How to Order Manifold 25A VV5Q 4 1 08 C8 T [Option] 0 CE compliant Series compatible with secondary batteries Nil Q Series 4 Option VQ4000 Box mounting position O D Manifold 1 Plug-in unit … 3 stations … 18 18 stations U side mounting D side mounting C8 With One-touch fitting for ø8 C10 With One-touch fitting for ø10 C12 With One-touch fitting for ø12 02 Rc 1/4 03 Rc 3/8 B Bottom ported Rc 1/4 CM Mixed Note) 2 stations are used for mounting the terminal block box. The number of stations is the number of manifold valves plus 2 stations for the terminal block box. For 13 stations or more, specify the wiring specifications by means of the manifold specification sheet. Symbol Nil K (2) Cylinder port Stations 03 — CE compliant Note) As an option, the maximum number of stations can be increased by special wiring specifications. N (3) W Option None Special wiring specifications (Except double wiring, for 13 stations or more) Name plate IP65 enclosure Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -KM Note 2) Specify the wiring specifications on the manifold specification sheet. Note 3) Name plate is inlaid in the terminal block cover. Note 4) With control unit is the same as standard products. How to Order Valves VQ 4 1 0 1 25A [Option] 5 CE compliant Series compatible with secondary batteries Nil Q Series 4 Enclosure VQ4000 Nil Type of actuation 1 2 3 4 5 6 W 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 position double check Dustproof Dust-tight / Water-jets-proof type (IP65) Manual override Nil B Nil E Rubber seal Function Standard type (1 W) Nil Y (1) Low wattage type (0.5 W) External pilot R (2) Note 1) Applicable to DC specifications.Please select when you expect to energize the unit for extended periods of time. Note 2) External pilot specifications are the same as standard products. Combination of external pilot and perfect interface is not possible. Note 3) When two or more symbols are specified, indicate them alphabetically. Non-locking push type (Tool required) Locking type (Tool required) Light / Surge voltage suppressor Seal 1 37 — CE compliant Yes Without light, with surge voltage suppressor Coil voltage 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC ∗ Specifications and dimensions for the 25A-series are the same as standard products. 25A-VQ4000 08 C8 L D Series compatible with secondary batteries Series 4 CE compliant Nil Q VQ4000 Symbol Nil W Plug-in unit Stations … — CE compliant Option Manifold 1 01 1 stations … 16 16 stations Option None IP65 enclosure Cable (Length) 0 1 2 Cylinder port Cable length 0.6 m Cable length 1.5 m Cable length 3 m Connector locations C8 With One-touch fitting for ø8 C10 With One-touch fitting for ø10 C12 With One-touch fitting for ø12 02 Rc 1/4 03 Rc 3/8 B Bottom ported Rc 1/4 CM Mixed D U D side entry U side entry How to Order Valves 25A VQ 4 1 0 1 [Option] 5 CE compliant Series compatible with secondary batteries Series 4 Nil Q Nil W 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 position double check 1 Dustproof Dust-tight/Water-jets-proof type (IP65) Manual override Nil B Nil E Rubber seal Function Standard type (1 W) Low wattage type (0.5 W) External pilot Note 1) Applicable to DC specification. Please select when you expect to energize the unit for extended periods of time. Note 2) External pilot specifications are the same as standard products. Combination of external pilot and perfect interface is not possible. Note 3) When two or more symbols are specified, indicate them alphabetically. Non-locking push type (Tool required) Locking type (Tool required) Light /Surge voltage suppressor Seal Nil Y (1) R (2) — CE compliant Enclosure VQ4000 Type of actuation 1 2 3 4 5 6 Related Products 25A VV5Q 4 1 [Option] Yes Without light, with surge voltage suppressor Coil voltage 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC ∗ Specifications and dimensions for the 25A-series are the same as standard products. 38 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators How to Order Manifold Auto Switches Series Directional Actuators Control Valves Plug-in Unit/Base Mounted L Kit (Lead wire cable) Plug-in Unit/Base Mounted S Kit (Serial transmission unit) 25A-VQ4000 Series Note) Refer to “SI Unit Part No.” when ordering the [Option] CE-compliant SI unit. How to Order Manifold 25A VV5Q 4 1 08 C8 S D V CE compliant Nil Q Series compatible with secondary batteries Option Series 4 Symbol Nil VQ4000 K (2) Manifold 1 — CE compliant W Plug-in unit Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -KW Note 2) Specify the wiring specifications in the manifold specification sheet. Note 3) With control unit is the same as standard products. Note 4) The release valve and the pressure switch on the manifold with control unit are connected to another power supply. Cable length is 0.6 m for L kit. Stations Note) 2 stations are used for 03 3 stations … mounfing SI unit. The … number of stations is the 18 18 stations number of manifold valves plus 2 stations for SI unit. For 11 stafions or more, specify the wiring specifications Cylinder ports by means of the C8 With One-touch fitting for ø8 manifold specification C10 With One-touch fitting for ø10 sheet. C12 With One-touch fitting for ø12 02 Rc 1/4 03 Rc 3/8 B Bottom ported Rc 1/4 CM Mixed Option None Special wiring specifications (Except double wiring, for 11 stations or more) IP65 enclosure SI unit 0 Q V Without SI unit DeviceNet™ CC-Link SI unit mounting position D D side mounting U U side mounting How to Order Valves 25A Series compatible with secondary batteries VQ 4 1 0 1 [Option] 5 CE compliant Nil Q Series 4 VQ4000 Enclosure Type of actuation 1 2 3 4 5 6 Nil 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 position double check W Nil B Standard type (1 W) Low wattage type (0.5 W) External pilot Note 1) Applicable to DC specifications. Please select when you expect to energize the unit for extended periods of time. Note 2) External pilot specifications are the same as standard products. Combination of external pilot and perfect interface is not possible. Note 3) When two or more symbols are specified, indicate them alphabetically. 39 Non-locking push type (Tool required) Locking type (Tool required) Light /Surge voltage suppressor Rubber seal Nil E Function Nil Y (1) R (2) Dustproof Dust-tight/Water-jets-proof type (IP65) Manual override Seal 1 — CE compliant Yes Without light, with surge voltage suppressor Coil voltage 5 24 VDC ∗ Specifications and dimensions for the 25A-series are the same as standard products. Plug Lead Unit/Base Mounted C Kit (Connector kit) [Option] Directional Actuators Control Valves 25A-VQ4000 How to Order Manifold 08 C8 C W Nil Q Refer to the standard products. Manifold Kit type Stations … Symbol Nil W Control unit VQ4000 Plug lead unit 5 — CE compliant Option Series 4 Related Products CE compliant Series compatible with secondary batteries 01 1 stations … 16 16 stations C kit (Connector) C Connector kit Option None IP65 enclosure Cylinder port C8 With One-touch fitting for ø8 C10 With One-touch fitting for ø10 C12 With One-touch fitting for ø12 02 Rc 1/4 03 Rc 3/8 B Bottom ported Rc 1/4 CM Mixed Max. 16 stations Refer to Best Pneumatics No. 1 for wiring specifications. How to Order Valves 25A VQ 4 1 5 1 5 G CE compliant Nil Q Enclosure Series compatible with secondary batteries Series 4 Nil W Manual override Light/Surge voltage suppressor 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 position double check Nil E G Rubber seal Grommet 1 Function Standard type (1 W) Low wattage type (0.5 W) External pilot Note 1) Applicable to DC specifications. Please select when you expect to energize the unit for extended periods of time. Note 2) External pilot specifications are the same as standard products. Combination of external pilot and perfect interface is not possible. Note 3) When two or more symbols are specified, indicate them alphabetically. Yes Without light, with surge voltage suppressor B: Nil: Non-locking push type Locking type (Tool required) (Tool required) Electrical entry Seal Nil Y (1) R (2) Dustproof Dust-tight/Water-jets-proof type (IP65) VQ4000 Type of actuation 1 2 3 4 5 6 — CE compliant Lead wire length 0.6 m H Lead wire length 1.5 m Coil voltage 1 2 3 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 4 5 6 220 VAC (50/60 Hz) 24 VDC 12 VDC ∗ Specifications and dimensions for the 25A-series are the same as standard products. 40 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators VV5Q 4 5 25A Auto Switches Series Series 25A-VQ4000 Manifold Option Parts Blanking plate assembly 25A-VVQ4000-10A-1 (Plug-in type) 25A-VVQ4000-10A-5 (Plug lead type) It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. ∗ Specifications and dimensions for the 25A-series are the same as standard products. SI Unit Part No. Part no. EX124D-SMJ1-X220 EX124D-SDN1-X220 EX124U-SMJ1-X220 EX124U-SDN1-X220 Note CC-Link/D side mounting DeviceNet™/D side mounting CC-Link/U side mounting DeviceNet™/U side mounting Port size ø4 One-touch fitting (Straight type) ø6 One-touch fitting (Straight type) ø8 One-touch fitting (Straight type) Metric size ø10 One-touch fitting (Straight type) ø12 One-touch fitting (Straight type) ø10 One-touch fitting (Straight type) Metric size 25A-VQ4000 Description EX124 SI unit One-touch Fittings Part No. Cylinder port 1(P), 3(R) port 41 90-VVQ4000-50B-C8 90-VVQ4000-50B-C10 90-VVQ4000-50B-C12 How to Order Manifold 25A SS5Q23 08 FD2 Series compatible with secondary batteries 1 station 16 stations 16 Note) Note) The maximum number of stations depends on the type of electrical entries. Manifold mounting DIN rail mounting style Direct mounting style D E Note) CE compliant Nil Q Option Stations 01 D Nil 02 to 16 (1) B (2) K (3) N R None DIN rail length specified Back pressure check valve Special wiring specifications (Except double wiring) With name plate (Side ported only) External pilot specifications — CE compliant 1(P), 3(R) port size Nil 00T 1(P), 3(R) port One-touch fittings for ø10 1(P), 3(R) port One-touch fittings for ø3/8" Note 1) Specify DIN rail length with “D at the end. (Enter the number of stations inside .) The number of stations that may be displayed is longer than the manifold number of stations. Example: -D08 Note 2) When installing back pressure check valves only on the stations required, enter the part number and specify the mounting stations on a manifold specification sheet. Note 3) Standard wiring specifications are for double wiring. Indicate wiring specifications for single wiring or mixed single and double wiring, or when exceeding the standard maximum number of stations. (Except L kit.) Note 4) For specifying two or more options, enter them alphabetically. Example: -BKN ∗ Manifold option parts are the same as standard products. Electrical entry Lead wire connector location Kit type F kit The electric parts are made of copper. D-sub D side connector kit Mounting screw: Stainless steel U side One-touch fitting Body: Stainless steel Cable specifications Station Max. number (2) of stations for Max. number special wiring of solenoids specifications D side D-sub connector (25P) kit, without cable D-sub connector (25P) kit, with 1.5 m cable D-sub connector (25P) kit, with 3.0 m cable D-sub connector (25P) kit, with 5.0 m cable 1 to 12 stations 16 stations 24 TD0 D side Terminal block box kit 1 to 10 stations 16 stations 16 LD0 LU0 LD1 LU1 LD2 LU2 D side U side D side U side D side U side FD0 FD1 FD2 FD3 T kit Terminal block box kit L kit Mounting screw: Stainless steel One-touch fitting Body: Stainless steel Lead wire kit S kit Lead wire kit with 0.6 m cable Lead wire kit with 1.5 m cable 1 to 12 stations — — Lead wire kit with 3.0 m cable Mounting screw:Stainless steel SDQ The electric parts are made of copper. 1 to 8 stations 16 stations 16 CC-Link 1 to 8 stations 16 stations 16 D side One-touch fitting Body: Stainless steel Serial transmission kit EX140 integrated-type (for output) serial transmission system (3) DeviceNet™ SDV Note 1) The maximum number of stations should not be more than the maximum number of solenoids. (The number of solenoids are counted as: 1 for single solenoids and 2 for type 3P and 4P double solenoids.) Note 2) Refer to Best Pneumatics No. 1 for the details of EX140 integrated-type (for output) serial transmission system. Refer to “SI unit part no.” when ordering the CE-compliant SI unit. SI unit part no. Symbol Protocol type SDQ DeviceNet™ SDV CC-Link SI unit part no. EX140-SDN1-X220 EX140-SMJ1-X220 Page P.46 Blanking plate assembly 25A-SSQ2000-10A-3 ∗ Specifications and dimensions for the 25A-series are the same as standard products. 42 Related Products [Option] Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators 25A-SQ2000 Auto Switches Series Directional Actuators Control Valves Plug-in Unit Series 25A-SQ2000 How to Order Valves 25A SQ2 1 3 1 5 [Option] C6 CE compliant Series compatible with secondary batteries — CE compliant Nil Q With/Without manifold block Nil M With manifold block Without manifold block Type of actuation MB With manifold block, built-in back pressure check valve 2 position single 1 2 position double(Latching) (Metal seal, Rubber seal) 2 2 position double (Double solenoid) (1) (Rubber seal) 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center ∗ Lead wire is not included. ∗ Lead wire is not included. • When ordering with manifolds • When only valves are required. Port plug mounting port (2) 4 position dual 3 port valve A (N.C./N.C.) Nil A B (2) 4 position dual 3 port valve B (N.O./N.O.) (2) 4 position dual 3 port valve C (N.C./N.O.) C4 C6 C8 L4 L6 L8 Rubber seal Side ported (1) Top ported Manual override Nil Non-locking push type (Tool required) Function D One-touch fittings for ø4 One-touch fittings for ø6 One-touch fittings for ø8 One-touch fittings for ø4 One-touch fittings for ø6 One-touch fittings for ø8 Note 1) Can be changed to side ported configuration. Note 2) Refer to the standard products for the inch-size One-touch fittings. Seal Nil None Port 4(A) Port 2(B) Cylinder port Note 1) For double solenoid specification, the function symbol below is “D”. Note 2) Only rubber seal types are applicable. 1 For adding stations Standard type (1.0 W DC) 2 position double (Double solenoid specifications) B Note) Locking type (Tool required) D Note) Slide locking type (Manual type) ∗ Only side ported type applicable (Latching type: Nil) Negative common Y(1)(2) Low wattage type (0.5 W DC) R(3) External pilot specifications N Note 1) Except double (latching) type. Note 2) Please select when you expect to energize the unit for extended periods of time. Note 3) Except dual 3 port valves. Note 4) When two or more symbols are specified, indicate them alphabetically. Note) Except double (latching) type. Coil voltage 5 6 24 VDC 12 VDC Note 1) Light/Surge voltage suppressor is built-in. Note 2) S kit: 24 VDC only ∗ Specifications and dimensions for the 25A-series are the same as standard products. 43 [Option] How to Order Manifold 25A SS5Q24 08 FD2 D Nil Q Related Products CE compliant Series compatible with secondary batteries — CE compliant 1(P), 3(R) port size Nil 00T Stations 01 1 station 16 Note) 16 stations 1(P), 3(R) port, One-touch fittings for ø10 1(P), 3(R) port, One-touch fittings for ø3/8" Option Nil 02 to 16 (1) B K (2) N R Note) The maximum number of stations depends on the type of electrical entries. Manifold mounting D E Note) DIN rail mounting style Direct mounting style Note) Type E is only available with a C kit. None DIN rail length specified Back pressure check valve Special wiring specifications (Except double wiring) With name plate (Side ported only) External pilot specifications Note 1) Specify DIN rail length with “D at the end. (Enter the number of stations inside .) The number of stations that may be displayed is longer than the manifold number of stations. Example: -D08 Note 2) When installing back pressure check valves only on the stations required, enter the part number and specify the mounting stations on a manifold specification sheet. Note 3) Standard wiring specifications are for double wiring. Indicate wiring specifications for single wiring or mixed single and double wiring, or when exceeding the standard maximum number of stations. (Except C kit.) Note 4) For specifying two or more options, enter them alphabetically. Example: -BKN ∗ Manifold option parts are the same as standard products. Electrical entry Lead wire connector location Kit type Mounting screw: Stainless steel F kit The electric parts are made of copper. D side D-sub connector kit C kit Connector kit U side One-touch fitting Body: Stainless steel FD0 FD1 FD2 FD3 D side C — Cable specifications Stations Max. number (1) of stations for Max. number special wiring of solenoids specifications D-sub connector (25P) kit, without cable D-sub connector (25P) kit, with 1.5 m cable D-sub connector (25P) kit, with 3.0 m cable D-sub connector (25P) kit, with 5.0 m cable 1 to 12 stations 16 stations 24 Connector kit 1 to 16 stations — Mounting screw: Stainless steel — One-touch fitting Body: Stainless steel Note 1) The maximum number of stations should not be more than the maximum number of solenoids. (The number of solenoids are counted as: 1 for single solenoids and 2 for type 3P and 4P double solenoids.) ∗ Refer to Best Pneumatics No. 1 for manifold spare parts. Blanking plate assembly 25A-SSQ2000-10A-4 ∗ Specifications and dimensions for the 25A-series are the same as standard products. 44 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators 25A-SQ2000 Auto Switches Series Directional Actuators Control Valves Plug Lead Unit Series 25A-SQ2000 How to Order Valves 25A SQ2 1 4 1 5 L [Option] C6 CE compliant Series compatible with secondary batteries Nil Q — CE compliant With/Without manifold block M MB With manifold With manifold block, built-in block back pressure check valve Nil Without manifold block Type of actuation 2 position single 1 2 position double(Latching) (Metal seal, Rubber seal) 2 2 position double (Double solenoid) (1) (Rubber seal) 3 3 position closed center 4 3 position exhaust center 5 3 position pressure center (2) 4 position dual 3 port valve ∗ Lead wire is not included. ∗ Lead wire is not included. • When ordering with manifolds • When only valves are required. Port plug mounting port (2) 4 position dual 3 port valve B (N.O./N.O.) Cylinder port 4 position dual 3 port valve C4 C6 C8 L4 L6 L8 C (N.C./N.O.) Note 1) For double solenoid specification, the function symbol below is “D”. Note 2) Only rubber seal types are applicable. Rubber seal D Side ported (1) Top ported Manual override Nil Non-locking push type (Tool required) Function Nil One-touch fitting for ø4 One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø4 One-touch fitting for ø6 One-touch fitting for ø8 Note 1) Can be changed to side ported configuration. Note 2) Refer to the standard products for the inch-size One-touch fittings. Seal 1 None Port 4(A) Port 2(B) Nil A B A (N.C./N.C.) (2) For adding stations Standard type (1.0 W DC) 2 position double (Double solenoid specifications) (Latching type: Nil) Negative COM N Y(1)(2) Low wattage type (0.5 W DC) R(3) External pilot specifications B Note) Locking type (Tool required) D Note) Slide locking type (Manual type) ∗ Only side ported type applicable Note) Except double (latching) type. Note 1) Except double (latching) type. Note 2) Please select when you expect to energize the unit for extended periods of time. Note 3) Except dual 3 port valves. Note 4) When two or more symbols are specified, indicate them alphabetically. Electrical entry L Plug connector type with 300 mm lead wire LO Plug connector type without connector Coil voltage 5 6 24 VDC 12 VDC Note) Light/Surge voltage suppressor is built-in. For F, P, J kit manifolds Note) Note) Indicate “LO” when ordering centralized wiring type manifolds, F, P, and J kits, since the lead wire will be attached to the manifold side. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 45 Plug Lead Unit Series 25A-SQ2000 Part no. 25A-SS5Q23 EX140-SMJ1-X220 EX140-SDN1-X220 Description EX140 SI unit Directional Actuators Control Valves SI Unit Part No. Note CC-Link DeviceNetTM One-touch Fittings Part No. 1(P), 3(R) port Metric size ø4 One-touch fitting (Straight type) ø6 One-touch fitting (Straight type) ø8 One-touch fitting (Straight type) ø10 One-touch fitting (Straight type) 90-VVQ1000-51A-C4 90-VVQ1000-51A-C6 90-VVQ4000-51A-C8 90-VVQ2000-51A-C10 Related Products Metric size Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Cylinder port 25A-SQ2000 Auto Switches Port size 46 5 Port Solenoid Valve Base Mounted Series 25A-VQZ1000 Single Unit Plug Lead Unit [Option] How to Order Valve 25A VQZ 1 1 5 1 5 M 1 01 CE compliant Series compatible with secondary batteries Series Nil Q Note) DC-type only. 1 VQZ1000 body width 10 mm Port size Symbol Port size Without sub-plate Nil Rc1/8 01 Type of actuation 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 port for mixture mounting N.C. 3 port for mixture mounting N.O. 1 2 3 4 5 8 9 — CE compliant Manual override Nil: Non-locking B: Locking type push type (Tool required) (Tool required) Body type +- +- 5 Base mounted Seal type 1 Electrical entry Rubber seal LO: L-type M: M-type MO: M-type G: Grommet L: L-type plug plug plug plug (DC speciconnector connector connector connector fication) with lead without with lead without wire connector wire connector Function Symbol Specifications Nil Standard B High speed response type R External pilot type BR High speed response/External pilot type DC (0.35 W) AC (0.9 W) — (0.9 W) — With light/ With light/ With light/ With light/ surge voltage surge voltage surge voltage surge voltage suppressor suppressor suppressor suppressor -+ +− +- Coil voltage 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC [115 VAC] (50/60 Hz) 220 VAC [230 VAC] (50/60 Hz) 24 VDC 12 VDC Caution Use standard (DC) specification for continuous duty. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 47 [Option] How to Order Manifold CE compliant Series Series compatible with secondary batteries 1 Manifold type Option Base mounted Nil R Stations 02 2 stations None External pilot type Kit type … … — CE compliant Nil Q VQZ1000 5 Related Products 25A VV5QZ 1 5 08 C6 C R 20 20 stations C Connector Port size [4(A), 2(B) port] Symbol C4 C6 M5 CM Note) Port size ø4 One-touch fitting ø6 One-touch fitting M5 thread Mixture of port sizes Note) Specify port mixture/with port plug by the manifold specification sheet. Port mixture and port plug are available only for One-touch fitting type. How to Order Valve 25A VQZ 1 1 5 1 5 M CE compliant Series compatible with secondary batteries Nil Q Series Manual override Type of actuation Nil B 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 port for mixture mounting N.C. 3 port for mixture mounting N.O. Body type Seal type 1 Function B High speed response type R External pilot type High speed response/ External pilot type DC (0.35 W) (0.9 W) (0.9 W) Caution Use standard (DC) specification for continuous duty. Symbol Electrical entry G L LO M MO Grommet (DC specification) L-type plug connector with lead wire L-type plug connector without connector M-type plug connector with lead wire M-type plug connector without connector Light/surge voltage suppressor None Yes Coil voltage Rubber seal Symbol Specifications Nil Standard Non-locking push type (Tool required) Locking type (Tool required) Electrical entry 5 Base mounted BR — CE compliant Note) DC-type only. 1 VQZ1000 body width 10 mm 1 2 3 4 5 8 9 1 AC — 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC [115 VAC] (50/60 Hz) 220 VAC [230 VAC] (50/60 Hz) 24 VDC 12 VDC — ∗ Specifications and dimensions for the 25A-series are the same as standard products. 48 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Series 25A-VQZ1000 Manifold Connector Kit Plug Lead Unit Auto Switches Base Mounted Directional Actuators Control Valves 5 Port Solenoid Valve 5 Port Solenoid Valve Body Ported Series 25A-VQZ1000 Single Unit Plug Lead Unit [Option] How to Order Valve 25A VQZ 1 1 2 1 5 M 1 C6 CE compliant Series compatible with secondary batteries Note) DC-type only. Option Series Nil: None F: With bracket 2 position single type only 1 VQZ1000 body width 10 mm Type of actuation 1 2 3 4 5 8 9 — CE compliant Nil Q 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 port for mixture mounting N.C. 3 port for mixture mounting N.O. +- Bracket Port size [4(A), 2(B) port] Symbol Port size C4 ø4 One-touch fitting C6 ø6 One-touch fitting M5 M5 thread Note) 3 port for mixture mounting is only available for port size C4 or C6. Manual override Nil: Non-locking B: Locking type push type (Tool required) (Tool required) +- +- Electrical entry G: Grommet L: L-type (DC speciplug fication) connector with lead wire With light/ surge voltage suppressor LO: L-type plug connector without connector With light/ surge voltage suppressor Body type 2 M: M-type plug connector with lead wire With light/ surge voltage suppressor MO: M-type plug connector without connector With light/ surge voltage suppressor -+ Body ported +− +- Seal type 1 Rubber seal Function Symbol Specifications DC AC Nil Standard (0.35 W) B High speed response type (0.9 W) — Caution Use standard (DC) specification for continuous duty. 49 Coil voltage 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC [115 VAC] (50/60 Hz) 220 VAC [230 VAC] (50/60 Hz) 24 VDC 12 VDC ∗ Specifications and dimensions for the 25A-series are the same as standard products. [Option] How to Order Manifold CE compliant Series Series compatible with secondary batteries 1 Nil Q VQZ1000 Manifold type 2 Related Products 25A VV5QZ 1 2 08 C — CE compliant Kit type Body ported C Connector Stations … … 02 2 stations 20 20 stations How to Order Valve 25A VQZ 1 1 2 1 5 M 1 C6 Series compatible with secondary batteries CE compliant Nil Q Series Port size [4(A), 2(B) port] Symbol C4 C6 M5 Type of actuation 1 2 3 4 5 Note) 8 Note) 9 Note) 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 port for mixture mounting N.C. 3 port for mixture mounting N.O. Nil B Body ported Seal type Rubber seal Function Symbol Nil B Non-locking push type (Tool required) Locking type (Tool required) Electrical entry Body type 1 Port size ø4 One-touch fitting ø6 One-touch fitting M5 thread Manual override Note) 3 port for mixture mounting is only available for port size C4 or C6. 2 — CE compliant Note) DC-type only. 1 VQZ1000 body width 10 mm Specifications DC AC Standard (0.35 W) High speed response type (0.9 W) — Caution Use standard (DC) specification for continuous duty. Symbol Electrical entry G L LO M MO Grommet (DC specification) L-type plug connector with lead wire L-type plug connector without connector M-type plug connector with lead wire M-type plug connector without connector Light/surge voltage suppressor None Yes Coil voltage 1 2 3 4 5 6 Directional Actuators Control Valves Series 25A-VQZ1000 Manifold Connector Kit 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC [115 VAC] (50/60 Hz) 220 VAC [230 VAC] (50/60 Hz) 24 VDC 12 VDC ∗ Specifications and dimensions for the 25A-series are the same as standard products. 50 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators Plug Lead Unit Auto Switches Body Ported 5 Port Solenoid Valve Plug-in Unit Base Mounted 25A-VQ1000/2000 Double check block (Separated) Series How to Order Double check block 25A VQ1000 FPG C4 M5 F Option Series compatible with secondary batteries M5 C3 C4 C6 IN side port size OUT side port size M5 thread ø3.2 One-touch fitting ø4 One-touch fitting ø6 One-touch fitting M5 C3 C4 C6 M5 thread ø3.2 One-touch fitting ø4 One-touch fitting ø6 One-touch fitting Manifold (DIN rail mounting) Nil F D N None With bracket DIN rail mounting (For manifold) Name plate Note) When two or more symbols are specified, indicate them alphabetically. Example) -DN 25A VVQ1000 FPG 06 Series compatible with secondary batteries Stations 01 16 1 station … <Ordering example> 25A-VVQ1000-FPG-06…6-station manifold ∗ 25A-VQ1000-FPG-C4M5-D; Double 3set ∗ 25A-VQ1000-FPG-C6M5-D; check block 3set … When ordering a double check block, order the DIN rail mounting [-D]. 16 stations Bracket Assembly Part no. Tightening torque 25A-VQ1000-FPG-FB 0.22 to 0.25 N·m Double check block 25A VQ2000 FPG 01 01 F Series compatible with secondary batteries Option Nil IN side port size 01 02 C6 C8 Rc 1/8 Rc 1/4 ø6 One-touch fitting ø8 One-touch fitting OUT side port size D Rc 1/8 Rc 1/4 ø6 One-touch fitting ø8 One-touch fitting F N 01 02 C6 C8 Manifold (DIN rail mounting) None DIN rail mounting (For manifold) With bracket Name plate Note) When two or more symbols are specified, indicate them alphabetically. Example) -DN 25A VVQ2000 FPG 06 Series compatible with secondary batteries Stations 16 1 station … <Ordering Example> 25A-VVQ2000-FPG-06…6-station manifold ∗ 25A-VQ2000-FPG-C6C6-D; 3set Double ∗ 25A-VQ2000-FPG-C8C8-D; check block 3set 01 … When ordering a double check block, order the DIN rail mounting [-D]. 16 stations Bracket Assembly Tightening torque Part no. 0.8 to 1.0 N·m 25A-VQ2000-FPG-FB ∗ Specifications and dimensions for the 25A-series are the same as standard products. 51 25A-VP342/542/742 Note) Only DIN and conduit terminal types are available for AC mode. Refer to the electrical entry for details. 25A VP 3 4 2 Series compatible with secondary batteries 5 D 1 01 Thread type Series 3 5 7 Nil F N T VP300 VP500 VP700 Pilot type Nil R Rc G NPT NPTF Type of actuation Internal pilot External pilot Pressure specification Nil K A N.C. (Normally closed) B N.O. (Normally open) Standard (0.7 MPa) High-pressure type (1.0 MPa) Bracket Coil specification Nil T A Related Products Body ported Standard With power saving circuit (DC only) Note) Be sure to select the power saving circuit type when it is continuously energized for a long time. ∗ T type is only available for DC mode. When T is selected, only Z type of light/surge voltage suppressor is available. Nil F Rated voltage DC 5 24 VDC 6 12 VDC AC (50/60 Hz) 1 100 VAC 2 200 VAC 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] 7 240 VAC B 24 VAC Without bracket With bracket Port size Symbol Port size VP300 VP500 VP700 1/8 01 — — 1/4 02 — 3/8 03 — 1/2 04 — — Electrical entry DIN DIN Conduit (EN175301-803) terminal terminal terminal [IP65 compatible] [IP65 compatible] [IP65 compatible] Manual override Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type D: With connector Y: With connector T: Conduit terminal DC CE compliant AC Light /surge voltage suppressor Nil S Z R U Without light /surge voltage suppressor With surge voltage suppressor With light /surge voltage suppressor With surge voltage suppressor (Non-polar) With light /surge voltage suppressor (Non-polar) DC AC Note) — — — Note) There is no S option for AC mode, since a rectifier prevents surge voltage generation. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 52 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators How to Order Auto Switches Series Directional Actuators Control Valves Rubber Seal 3 Port/Pilot Poppet Type Rubber Seal 3 Port/Pilot Poppet Type Series 25A-VP344/544/744 Note) Only DIN and conduit terminal types are available for AC mode. Refer to the electrical entry for details. How to Order Base mounted 25A VP 3 4 4 Series compatible with secondary batteries 5 D 1 01 Thread type Series 3 5 7 Nil F N T VP300 VP500 VP700 Internal pilot External pilot A N.C. (Normally closed) B N.O. (Normally open) Pressure specification Nil K Standard (0.7 MPa) High-pressure type (1.0 MPa) Coil specification Nil T Rc G NPT NPTF Type of actuation Pilot type Nil R A Standard With power saving circuit (DC only) Note) Be sure to select the power saving circuit type when it is continuously energized for a long time. ∗ T type is only available for DC mode. When T is selected, only Z type of light/surge voltage suppressor is available. Port size (Sub-plate) Rated voltage DC 5 24 VDC 6 12 VDC Symbol Port size VP300 VP500 VP700 Without sub-plate∗ Nil 1/8 — — 01 1/4 — 02 3/8 — 03 1/2 — — 04 AC (50/60 Hz) 1 100 VAC 2 200 VAC 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] 7 240 VAC B 24 VAC ∗ With a gasket and two mounting bolts. Electrical entry DIN Conduit (EN175301-803) terminal terminal [IP65 compatible] [IP65 compatible] [IP65 compatible] DIN terminal Manual override Nil: Non-locking push type D: Push-turn locking slotted type E: Push-turn locking lever type D: With connector Y: With connector T: Conduit terminal DC CE compliant AC Light /surge voltage suppressor Nil S Z R U Without light /surge voltage suppressor With surge voltage suppressor With light /surge voltage suppressor With surge voltage suppressor (Non-polar) With light /surge voltage suppressor (Non-polar) DC AC Note) — — — Note) There is no S option for AC mode, since a rectifier prevents surge voltage generation. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 53 25A-VT317 Rubber Seal Series [Option] Note) CE compliant: For DIN terminal type. How to Order 02 Related Products G Body type T O Body ported Manifold Thread type Valve option Nil E∗ V∗ Standard type Continuous duty type For vacuum CE compliant Rated voltage 100 VAC,50 60 200 VAC,50 60 110 VAC,50 60 220 VAC,50 60 24 VDC 12 VDC 240 VAC,50 60 Other — CE compliant∗ Nil Q ∗ Semi-standard 1 2 3∗ 4∗ 5 6∗ 7∗ 9∗ Rc G NPT NPTF Nil F N T Series compatible with secondary batteries Note) Applicable only for DIN terminal type. Hz Hz Hz Hz Port size Without port (For manifold) 1 4 (8A) Nil Hz 02 Note) Applicable only for DIN terminal type. ∗ Semi-standard Electrical entry G H C T D Grommet, 300 mm lead wire Grommet, 600 mm lead wire Conduit Conduit terminal DIN terminal Light/Surge voltage suppressor CE compliant CE compliant — — — — Electrical entry Symbol Nil S Z G H C T D D Only — — — — — Note) Note) Note) — — — S:With surge voltage suppressor Note) Refer to the figure below. Z: With light /surge voltage suppressor ∗ As to the case of rated voltage [Others (9)], please contact SMC. Surge voltage suppressor mounting part (For “G”) Surge voltage suppressor Manifold Model Applicable manifold type VO317(-Q) Common or individual exhaust Accessory O-ring (P10, 4 pcs.) Note) Bolts (M4 x 0.7 x 20, 2 pcs.) Note) It is not applied to “Continuous duty type”. Refer to the accessories in Best Pneumatics No. 1. ∗ Specifications and dimensions for the 25A-series are the same as standard products. 54 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators 1 Auto Switches 25A V T 317 Directional Actuators Control Valves 3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type 25A-VG342 Rubber Seal Series [Option] Note) CE compliant: For DIN terminal only How to Order Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) 25A VG342 No lubrication required Possible to use in vacuum or under low pressures 5 D 04 A Series compatible with secondary batteries External pilot Vacuum: Up to –101.2 kPa Low pressure: 0 to 0.2 MPa CE compliant Nil Valve option Nil R Changeable actuation: N.C., N.O., or external pilot Can be used as a selector or divider valve (External pilot) Internal pilot External pilot Pilot valve option Rated voltage 5 6∗ — Q CE compliant Note) Note) Applicable only for DIN terminal type Nil Y∗ E∗ 24 VDC 12 VDC Note) Applicable only for DIN terminal type ∗ Semi-standard Standard type Energy-saving type (DC only) Continuous duty type ∗ Option Passage symbol Nil A B Electrical entry CE compliant D DIN terminal External pilot N.C. (Normally closed) N.O. (Normally open) Thread type Nil Light /Surge voltage suppressor Nil Z None With light /surge voltage suppressor (Except grommet type) Rc Port size 04 06 10 12 34 1 ∗ Specifications and dimensions for the 25A-series are the same as standard products. 55 25A-VHK RoHS How to Order 02S Series compatible with secondary batteries Related Products 02S Bracket Valve model 2 3 Nil L 2 port valve 3 port valve ∗ Bracket and screws are attached. 1(P) port size 04F 06F 08F 01S 02S 03S None With L-bracket ø4 ø6 ø8 R1 8 R1 4 R3 8 Knob color 2 port valve Nil (Standard) 3 port valve 2 port valve R (Option) 3 port valve Gray Blue Red 2(A) port size 04F 06F 08F 01S 02S 03S ø4 ø6 ø8 R1 8 R1 4 R3 8 Standard Type Applicable tubing O.D. (mm) 1(P) Applicable tubing O.D. (mm) ø4 ø4 ø6 ø8 ø6 ø8 2(A) 1(P): One-touch fitting 2(A): Male thread Applicable tubing O.D. (mm) ø4 ø6 M5 18 14 38 1(P) Port size R 2(A) 1(P): Male thread 2(A): One-touch fitting ø8 Port size R 2(A) M5 18 ø4 ø6 1(P) Applicable tubing O.D. (mm) 1(P): One-touch fitting 2(A): One-touch fitting ø8 14 38 ∗ Specifications and dimensions for the 25A-series are the same as standard products. 56 Fittings/Flow Air Filters/Pressure Fluid Control Detection Clean Air Preparation Vacuum Air Grippers Rotary Equipment Switches Control Equipment Control Equipment Air Filters Equipment Equipment Actuators 25A VHK 2 Auto Switches Series Directional Actuators Control Valves Finger Valve