AV 23 SETTER Inline - VVS

Transcription

AV 23 SETTER Inline - VVS
AV 23 SETTER Inline
www.HYG.de
Balancing Valves
nach KTW
Advantages
• Accurate and quick balancing
without diagrams, tables or
measuring devices
Direct regulation, reading and shut-off of flows in systems
• The flow rate is displayed
directly in l/min
Description
Installation
Direct hydraulic balancing and control
of flows to consumers or in a subsystem. Balancing valves offer a
quick, easy and accurate method
of adjusting the flow rates through
heating, ventilation, air conditioning and cooling systems.
The valve can be installed in a horizontal, vertical or inclined position.
Care should be taken that the arrow
is pointing in the direction of the flow.
• Regulating valve with
adjustment scale
• Regulating valve with isolating
facility
• Can be installed in any position
• Additional types are also
available as make resistant
to dezincification.
Correct balancing of hydraulic circuits
ensures optimum energy distribution, resulting in more efficient and
economical operation in accordance
with the energy saving regulations provided for by legislation.
With Setter Inline balancing valves, any
qualified fitter can set the appropriate
flow rate using the unique flow measurement device, avoiding investments
in training and costly measuring devices.
Operation
The flow measurement is based
on the principle of a baffle float
with return spring. The flowmeter
is built into the housing.
AS-SI
The balancing can be carried out
with a screwdriver at the adjusting
screw. The reading position is the
bottom line of the baffle float.
OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com
AV 23 SETTER Inline
Specification text
Regulating and stop valve with direct
indication of the set flow rate in l/min.
Gauge with baffle float and return
spring.
Measured values can be set and read
directly at the sight glass without tables,
diagrams or measuring devices.
Low pressure loss.
Technical data
Max. operating temperature: 100 °C
Max. operating pressure: 10 bar
kVS value and flow measurement
range, see table type programme
Measuring accuracy: ±10%
(highest nominal flow)
Material:
Housing: see “type programme”
Sight glass: heat- and impact resistant
plastic
Seals: EPDM
Female thread to DIN 2999 / ISO 7 or
male thread G (cylindrical) to ISO 228
Fluids
aus Messing
Setter Inline Standard made
of brass
Bestell-Nr.
Code
no.
223.1202.000
223.1203.000
223.1204.000
223.1208.000
223.1209.000
DN
15
15
15
15
15
G × Rp
¾" × ½"
¾" × ½" ¾" × ½" ¾" × ½"
¾" × ½"
Messbereich
(l/min)
Measuring
range
(l/min)
0,3 – 1,5
0,6 – 2,4
1,0 – 3,5
2,0 – 8,0
3,0 – 12,0
kVS (m³/h)
0,25
0,6
1,35
1,8
1,85
Code no.
Bestell-Nr.
223.1233.000
223.1234.000
223.1238.000
223.1239.000
DN
15
15
15
15
G × G
Measuring range
(l/min)
Messbereich
(l/min)
¾" × ¾" 0,6 –   2,4
¾" × ¾" 1,0 –   3,5
¾" × ¾" 2,0 –   8,0
¾" × ¾" 3,0 – 12,0
kVS (m³/h)
0,6
1,35
1,8
1,85
223.1300.000
223.1302.000
223.1305.000
20
20
20
1" × 1" 4,0 – 15,0
1" × 1" 8,0 – 30,0
1" × 1"
10,0 – 40,0
5,0
5,0
5,0
Setter
Inlinemade
aus entzinkungsbeständigem
Setter Inline
of dezincification-resistant Messing
brass
Bestell-Nr.
Code no.
DN
G × Rp
Messbereich
(l/min)
Measuring range
(l/min) kVS (m³/h)
223.1204.104
223.1208.104
223.1209.104
15
15
15
¾" × ½"
¾" × ½" ¾" × ½" 1,0 –   3,5
2,0 –   8,0
3,0 – 12,0
1,35
1,8
1,85
Bestell-Nr.
Code no.
223.1233.104
223.1234.104
223.1238.104
DN
15
15
15
G × G
¾" × ¾"
¾" × ¾"
¾" × ¾"
Messbereich
(l/min)
Measuring range
(l/min)
0,6 – 2,4
1,0 – 3,5
2,0 – 8,0
kVS (m³/h)
0,6
1,35
1,8
Dimensions
G ¾"
G 1"
Rp ½"
SW 24
81
(WaterMark for DZR versions only)
81
nach KTW
104
www.HYG.de
• Water and proprietary additives
used against corrosion and freezing
• Heating water (VDI 2035)
• Cooling water
• Potable water certificates:
SVGW, KTW, ACS and WaterMark
Typenübersicht
Type
programme
G ¾"
Accessories
VF 10 System-connections
Compression fitting joint with nut, clamping ring and supporting sleeve
Code no.
G × mm Version for
210.3325.000 ¾" × 15 Copper pipe 15⁄1 eurocone
suitable for
Setter Inline DN 15
Connection with nut and tail piece
Code no.
G × R
210.6221.000 ¾" × ½"
210.6632.000 1" × ¾"
210.6222.000 ¾" × ½"
pipe thread
Thread ½" eurocone
Thread ¾" flat sealing
Thread ½" self-sealing
Setter Inline DN 15
Setter Inline DN 20
Setter Inline DN 15
OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com
AV 23 SETTER Inline
Correction curve water-glycol
Pressure loss diagrams
Simplified representation for Setter Inline in medium flow rate range.
Specific diagrams available for each Setter type
223.1202.000
DN 15 0,3…1,5 l/min
A – F = Valve position
er
at
38% glycol
Kinematic viscosity:
υ = 6.7 mm2/s
w
75%
lar
ge
e
op
ni
ng
Pressure loss mbar
Effective flow rate (scale nominal value 100%)
1000
100%
50%
25%
sm
a
p
ll o
en
A
100
B
10
C
D
E
F
ing
kvs = 0,25
1
0%
0%
25%
50%
75%
0
100%
DN 15
0,6 … 2,4 l/min
223.1204.XXX
223.1234.XXX
B – F = Valve position
1000
1
1,5
10
Flow rate l/min
Displayed flow rate in %
223.1203.000
223.1233.XXX
0,3
DN 15
1… 3,5 l/min
B – F = Valve position
1000
B
B
100
Pressure loss mbar
Pressure loss mbar
C
C
D
10
100
D
E
F
10
E
F
kvs = 1,35
kvs = 0,6
1
1
0
0,6
1
2,4
Flow rate l/min
10
1
3,5
10
Flow rate l/min
OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com
AV 23 SETTER Inline
Pressure loss diagrams
223.1208.XXX
223.1238.XXX
DN 15
2 … 8 l/min
223.1209.XXX
223.1239.000
DN 15
3 … 12 l/min
C – F = Valve position
B – F = Valve position
1000
1000
B
C
Pressure loss mbar
Pressure loss mbar
C
100
D
10
E
100
D
E
10
F
F
kvs = 1,85
kvs = 1,8
1
1
1
2
8
10
1
DN 20
10 12
100
Flow rate l/min
Flow rate l/min
223.1300.000
3
4 …15 l/min
223.1302.000
223.1305.000
B – F = Valve position
DN 20  8…30 l/min
DN 20
10…40 l/min
C – F = Valve position
1000
1000
B
C
100
Pressure loss mbar
Pressure loss mbar
Subject to modification. A-SI 07/2010 pdf e
C
D
10
E
F
D
100
E
10
F
kvs = 5,0
kvs = 5,0
1
1
1
4
10
15
Flow rate l/min
100
1
8 10
30 40
100
Flow rate l/min
OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com

Similar documents

Jaga`s DBE power for wall recesses

Jaga`s DBE power for wall recesses Installation in a wall recess DBE L Dimensions E H1

More information

TaperFit™

TaperFit™ Trial cups may be used to confirm the size selection made at pre-operative templating.The acetabulum is then prepared to accept bone cement which is applied according to usual practice.

More information

Dynacon - IMI Hydronic Engineering

Dynacon - IMI Hydronic Engineering Dynacon adjusts the flow rate in the individual heating circuits directly in l/h. This means hydraulic balancing is achieved in one simple operation. The set flow rate is constantly adapted, i.e. if ...

More information