AV 23 SETTER Inline - VVS
Transcription
AV 23 SETTER Inline - VVS
AV 23 SETTER Inline www.HYG.de Balancing Valves nach KTW Advantages • Accurate and quick balancing without diagrams, tables or measuring devices Direct regulation, reading and shut-off of flows in systems • The flow rate is displayed directly in l/min Description Installation Direct hydraulic balancing and control of flows to consumers or in a subsystem. Balancing valves offer a quick, easy and accurate method of adjusting the flow rates through heating, ventilation, air conditioning and cooling systems. The valve can be installed in a horizontal, vertical or inclined position. Care should be taken that the arrow is pointing in the direction of the flow. • Regulating valve with adjustment scale • Regulating valve with isolating facility • Can be installed in any position • Additional types are also available as make resistant to dezincification. Correct balancing of hydraulic circuits ensures optimum energy distribution, resulting in more efficient and economical operation in accordance with the energy saving regulations provided for by legislation. With Setter Inline balancing valves, any qualified fitter can set the appropriate flow rate using the unique flow measurement device, avoiding investments in training and costly measuring devices. Operation The flow measurement is based on the principle of a baffle float with return spring. The flowmeter is built into the housing. AS-SI The balancing can be carried out with a screwdriver at the adjusting screw. The reading position is the bottom line of the baffle float. OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com AV 23 SETTER Inline Specification text Regulating and stop valve with direct indication of the set flow rate in l/min. Gauge with baffle float and return spring. Measured values can be set and read directly at the sight glass without tables, diagrams or measuring devices. Low pressure loss. Technical data Max. operating temperature: 100 °C Max. operating pressure: 10 bar kVS value and flow measurement range, see table type programme Measuring accuracy: ±10% (highest nominal flow) Material: Housing: see “type programme” Sight glass: heat- and impact resistant plastic Seals: EPDM Female thread to DIN 2999 / ISO 7 or male thread G (cylindrical) to ISO 228 Fluids aus Messing Setter Inline Standard made of brass Bestell-Nr. Code no. 223.1202.000 223.1203.000 223.1204.000 223.1208.000 223.1209.000 DN 15 15 15 15 15 G × Rp ¾" × ½" ¾" × ½" ¾" × ½" ¾" × ½" ¾" × ½" Messbereich (l/min) Measuring range (l/min) 0,3 – 1,5 0,6 – 2,4 1,0 – 3,5 2,0 – 8,0 3,0 – 12,0 kVS (m³/h) 0,25 0,6 1,35 1,8 1,85 Code no. Bestell-Nr. 223.1233.000 223.1234.000 223.1238.000 223.1239.000 DN 15 15 15 15 G × G Measuring range (l/min) Messbereich (l/min) ¾" × ¾" 0,6 – 2,4 ¾" × ¾" 1,0 – 3,5 ¾" × ¾" 2,0 – 8,0 ¾" × ¾" 3,0 – 12,0 kVS (m³/h) 0,6 1,35 1,8 1,85 223.1300.000 223.1302.000 223.1305.000 20 20 20 1" × 1" 4,0 – 15,0 1" × 1" 8,0 – 30,0 1" × 1" 10,0 – 40,0 5,0 5,0 5,0 Setter Inlinemade aus entzinkungsbeständigem Setter Inline of dezincification-resistant Messing brass Bestell-Nr. Code no. DN G × Rp Messbereich (l/min) Measuring range (l/min) kVS (m³/h) 223.1204.104 223.1208.104 223.1209.104 15 15 15 ¾" × ½" ¾" × ½" ¾" × ½" 1,0 – 3,5 2,0 – 8,0 3,0 – 12,0 1,35 1,8 1,85 Bestell-Nr. Code no. 223.1233.104 223.1234.104 223.1238.104 DN 15 15 15 G × G ¾" × ¾" ¾" × ¾" ¾" × ¾" Messbereich (l/min) Measuring range (l/min) 0,6 – 2,4 1,0 – 3,5 2,0 – 8,0 kVS (m³/h) 0,6 1,35 1,8 Dimensions G ¾" G 1" Rp ½" SW 24 81 (WaterMark for DZR versions only) 81 nach KTW 104 www.HYG.de • Water and proprietary additives used against corrosion and freezing • Heating water (VDI 2035) • Cooling water • Potable water certificates: SVGW, KTW, ACS and WaterMark Typenübersicht Type programme G ¾" Accessories VF 10 System-connections Compression fitting joint with nut, clamping ring and supporting sleeve Code no. G × mm Version for 210.3325.000 ¾" × 15 Copper pipe 15⁄1 eurocone suitable for Setter Inline DN 15 Connection with nut and tail piece Code no. G × R 210.6221.000 ¾" × ½" 210.6632.000 1" × ¾" 210.6222.000 ¾" × ½" pipe thread Thread ½" eurocone Thread ¾" flat sealing Thread ½" self-sealing Setter Inline DN 15 Setter Inline DN 20 Setter Inline DN 15 OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com AV 23 SETTER Inline Correction curve water-glycol Pressure loss diagrams Simplified representation for Setter Inline in medium flow rate range. Specific diagrams available for each Setter type 223.1202.000 DN 15 0,3…1,5 l/min A – F = Valve position er at 38% glycol Kinematic viscosity: υ = 6.7 mm2/s w 75% lar ge e op ni ng Pressure loss mbar Effective flow rate (scale nominal value 100%) 1000 100% 50% 25% sm a p ll o en A 100 B 10 C D E F ing kvs = 0,25 1 0% 0% 25% 50% 75% 0 100% DN 15 0,6 … 2,4 l/min 223.1204.XXX 223.1234.XXX B – F = Valve position 1000 1 1,5 10 Flow rate l/min Displayed flow rate in % 223.1203.000 223.1233.XXX 0,3 DN 15 1… 3,5 l/min B – F = Valve position 1000 B B 100 Pressure loss mbar Pressure loss mbar C C D 10 100 D E F 10 E F kvs = 1,35 kvs = 0,6 1 1 0 0,6 1 2,4 Flow rate l/min 10 1 3,5 10 Flow rate l/min OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com AV 23 SETTER Inline Pressure loss diagrams 223.1208.XXX 223.1238.XXX DN 15 2 … 8 l/min 223.1209.XXX 223.1239.000 DN 15 3 … 12 l/min C – F = Valve position B – F = Valve position 1000 1000 B C Pressure loss mbar Pressure loss mbar C 100 D 10 E 100 D E 10 F F kvs = 1,85 kvs = 1,8 1 1 1 2 8 10 1 DN 20 10 12 100 Flow rate l/min Flow rate l/min 223.1300.000 3 4 …15 l/min 223.1302.000 223.1305.000 B – F = Valve position DN 20 8…30 l/min DN 20 10…40 l/min C – F = Valve position 1000 1000 B C 100 Pressure loss mbar Pressure loss mbar Subject to modification. A-SI 07/2010 pdf e C D 10 E F D 100 E 10 F kvs = 5,0 kvs = 5,0 1 1 1 4 10 15 Flow rate l/min 100 1 8 10 30 40 100 Flow rate l/min OSTACO AG · Steinackerstr. 6 · 8902 Urdorf · Switzerland · Phone ++41 (0)44 735 55 55 · Fax ++41 (0)44 735 55 02 · [email protected] · www.taconova.com
Similar documents
Jaga`s DBE power for wall recesses
Installation in a wall recess DBE L Dimensions E H1
More informationTaperFit™
Trial cups may be used to confirm the size selection made at pre-operative templating.The acetabulum is then prepared to accept bone cement which is applied according to usual practice.
More informationDynacon - IMI Hydronic Engineering
Dynacon adjusts the flow rate in the individual heating circuits directly in l/h. This means hydraulic balancing is achieved in one simple operation. The set flow rate is constantly adapted, i.e. if ...
More information