K Range - Rotork
Transcription
K Range - Rotork
K Range High Torque Electric Valve Actuators Redefining Flow Control Contents SectionPage K Range Actuator 3 K Range High Torque Features 4 Enclosure Options 5 Drive Options 6 K Range Performance Summary 7 Actuator Motors 8 Wiring Diagram 9 Dimensional Drawings 10 Rotork is the global market leader in valve automation and flow control. Our products and services are helping organisations around the world to improve efficiency, assure safety and protect the environment. We strive always for technical excellence, innovation and the highest quality standards in everything we do. As a result, our people and products remain at the forefront of flow control technology. Uncompromising reliability is a feature of our entire product range, from our flagship electric actuator range through to our pneumatic, hydraulic and electro-hydraulic actuators, as well as instruments, gearboxes and valve accessories. Rotork is committed to providing first class support to each client throughout the whole life of their plant, from initial site surveys to installation, maintenance, audits and repair. From our network of national and international offices, our engineers work around the clock to maintain our position of trust. Rotork. Redefining flow control. 2 K Range Actuator With the K Range high torque actuator, Rotork is now able to offer all the proven design advantages of its established ranges at higher torque values than have previously been possible. Available in three models, K4000, K5500 and K7000, these actuators offer torque ratings of up to 7000 Nm and thrust ratings of up to 1115 kN. Standard K Range high torque features include: • Double-sealing against the environment, protecting electrical integrity at all times • Standard wiring diagrams for any valve type • Thrust or non-thrust mounting flange dimensions to International (ISO) valve standards • Advanced counter switch mechanism featuring combined torque position limit switches at each end of travel • Integral starter and control circuit option (Rotork Syncropak) • Three base options for each size of actuator • Watertight enclosures Redefining Flow Control 3 K Range High Torque Features Syncroset 6 1 3 4 Syncroset actuators incorporate the motor and limit and torque switches only. This minimizes the electrical equipment at the valve location and is therefore particularly suitable for locations where access is difficult or where excessive vibration may be experienced. However the reversing starter must be separately specified, purchased, installed and tested by the customer and the valve control system is therefore incomplete until wired in the field. 2 Remote control indication and interlocks Three phase power supply Features 1. Low ratio worm / wormwheel gear combined with final spur reduction gear offering a combined drive efficiency above that of conventional worm reduction designs. The gearcase is oil filled for normal operation in a temperature range of -30 to +70 oC. Reversing contactor starter Auxilary limit switches Motor and thermostat Travel limit and torque switches Local Controls 2. Separate thrust bases providing increased stem acceptance and thrust if required. Base and flange dimensions to ISO standards. 3. Very advanced all metal counter switch mechanism featuring combined torque and position switch with torque switch latch which prevents valve hammering throughout travel with non-self-locking gears. Switch mechanism is quickly and easily set using only a conventional screwdriver. As with other Rotork designs, the reaction force on the wormshaft, in direct proportion to the output torque is used to trip the 'Open' and 'Close' adjustable torque switches. 4. Built-in squirrel cage motor with winding thermostat, specially designed for valve operation and combining low inertia with high torque. Class F insulation as standard. 5. Hammerblow backlash feature permitting motor to gain full speed before unsticking tight stem nuts, etc. 6. Hand/auto selector lever insures positive engagement of handwheel drive. Power drive automatically restored by motor start unless lever padlocked to prevent it. Generously proportioned wormdrive handwheel provided as standard operating through hammerblow mechanism. The side handwheel ratio is 90:1 giving a mechanical advantage of 33:1. Syncropak Rotork Syncropak actuators incorporate the starter and local controls with considerable economy in site wiring as shown. This arrangement also enables the essential elements of the valve control system to be factory wired and tested and sealed by Rotork Quality Control. Because Syncropak incorporates everything required for operation from a three phase supply, it can be tested on local control by the valvemaker and site contractor with undivided contractual responsibility by Rotork for reliable operation. Syncropak options increase economy and add system reliability by providing a high degree of fault monitoring. Interposing relays enable light current cable to be used for distant remote control and indication. See publication RCIE - 34 for details. Note: 'K' Range high torque actuators are manufactured with the same wiring diagram options as the Rotork 'K' Range product. In addition, the 'K' Range high torque counter switch mechanism can accept both extra end position and mid position switches. 7. High output speeds at high torque enable large valves to be operated quickly and permit favorable top mounted actuator configuration. Syncropak or Syncroset? Any motorised valve requires a reversing contactor starter to switch the three phase motor in response to control signals. This may be separately installed or incorporated in the actuator. Rotork Syncroset actuators require separate starter facilities. Rotork Syncropak actuators contain their own starter and control equipment in a factory sealed and tested package. 4 Remote control indication and interlocks Reversing contactor starter Auxilary Motor limit and switches thermostat Local Controls Travel limit and torque switches Three phase power supply `O' ring Enclosure Options Enclosure options All 'K' Range high torque actuators are o-ring sealed from the environment and the exclusive Rotork 'double-sealed' feature means that the terminal compartment is separately sealed from the rest of the enclosure to insure that the actuator is permanently protected even during long periods of on-site wiring when the terminal cover is removed. `O' ring Redefining Flow Control 5 173 205 79 Drive Options 5 114 Drive Options F40A Three basic output drive column assemblies are available as standard on all sizes of ‘K’ Range high torque actuators. 34 equi.spaced 356 PCDseparate base The F40A is a larger version of the F35AL which provides enlarged stem acceptance and maximum 415 thrust rating. 260 8 holes drilled thro' Dimensions shown below are to International (ISO) dimensions. 50 Pilot bore F35E The F35E is the basic torque only form. The center column is terminated with a Type 'E' bore diameter and keyway suitable for attachment to valve makers' gearbox, etc. 5 82 40 55 224 260 M36 M30 8 holes drilled thro' 40 equi.spaced 127 300 406 PCD 45 476 *Note: Optional Flange Type 3 & Type 4 with the following dimensions can be offered 5 260 356 PCD 82 8 Holes drilled and tapped M30 equi. spaced Type 3 : 8 x M24 x 216 spigot dia x 356 PCD x 415 OD 415 Type 4 : 8 x M30 x 230 spigot dia x 406 PCD x 476 OD M30 F35AL 79 173 205 5 45 The F35AL is a separate thrust base which is added to the standard gearcase and which contains its own sealed thrust bearing and aluminum bronze drive bush. This feature 260 maintains the maximum rising stem acceptance available 356 PCD 8through Holes drilled the and tapped actuator center column which in this form is 415 M30 equi. spaced simply fitted with a pair of male dogs which engage with the drive bush. 5 114 260 8 holes drilled thro' 34 equi.spaced 356 PCD 79 205 50 Pilot bore 173 415 5 114 260 8 holes drilled thro' 34 equi.spaced 356 PCD 260 M36 40 55 224 415 50 Pilot bore 5 127 300 8 holes drilled thro' 40 equi.spaced 406 PCD 476 40 55 224 260 M36 5 6 8 holes drilled thro' equi.spaced 127 300 406 PCD K Range Performance Summary Performance Data Spindle acceptance Actuator Size K4000 F35E Rising (mm) Non-rising (mm) Max. Thrust (kN) Rated Torque (Nm) - 82 - 4,000 K4000 F35AL 110 95 446 4,000 K4000 F40A 125 105 1,115 4,000 K5500 F35E - 82 - 5,500 K5500 F35AL 110 95 446 5,500 K5500 F40A 125 105 1,115 5,500 K7000 F35E - 82 - 7,000 K7000 F35AL 110 95 446 7,000 K7000 F40A 125 105 1,115 7,000 Stall torque is 1.2-1.6 of rated torque. Limit switch turns range for all sizes is 5-1250 output turns. Actuator Size Motor K4000 K5500 K7000 415 V 50 Hz 3-ph Output Speed (rpm) Approx. Current A (Amps) Av. Load Power Factor Efficiency (%) 4.8 0.65 65 7.5 0.71 71 21 7.5 0.71 71 40 21 7.5 0.71 71 51 21 7.5 0.71 71 160 59 25 9.2 0.70 73 20 140 55 21 7.5 0.71 71 30 160 65 25 9.2 0.70 73 40 220 65 29 11.3 0.70 77 Locked Rotor Rated Torque Av. Load Nominal (kW) 20 120 35 15 30 140 40 21 40 140 48 20 140 30 140 40 Note: For other power supply options refer to Rotork. Redefining Flow Control 7 Actuator Motors Motors: Rotork actuator motors are 3-phase, minimum class 'F' insulated, and high torque low inertia motors of 15 minutes rating. The motors are spigot mounted and o-ring sealed to provide complete environmental protection during long periods of inactivity when condensation build up can otherwise cause deterioration. Valves have a limited travel and impose a varying load throughout the stroke and consequently the valve actuator motor cannot run continuously and conventional "FULL LOAD" ratings are not relevant. The following performance characteristics are standard for our motors: 1) A high stalling torque in comparison with that required to operate and seat valve will be available at high speed for unseating in with a lost motion hammer blow effect which is achieved by allowing the motor to reach full speed before the drive is taken up. 2) A relatively high starting torque to enable the valve to be inched. Hence our motors are short time rated, as the high inertia of continuously rated motors will inevitably damage the valves which are basically for "STOP DEAD" applications. Number of starts Motor is integral with actuator and hence as standard protected IP68 – IS/IEC-60529 enclosure. Protection 60 starts / hour. Thermostat embedded in stator winding. Bearing Deep groove sealed ball bearing lubricated for life available. Fan Cooling The design of Rotork motors are such that it renders fan cooling unnecessary to achieve the 15 min rating. 8 Wiring Diagram Syncroset wiring Diagram/coding CIRCUIT DRAWN FOR VALVE IN THE SHUT POSITION MOTOR U V 3ph 44 OPEN WD THERMOSTAT Connect 43 and 44 in series with both contactors. W 43 CLOSE 1 2 3 4 5 6 7 8 ABCEFGHIJKLMN- 0 1 2 3 1 2 3 4 39 9 Blinker 40 1 3 42 Ref.Note 1 7 9 0 8 11 FR 12 10 33 34 35 13 14 FR 15 72 Potentiometer 36 Fixed Resistor 37 38 17 18 POT 20 33 19 CPT 34 - 35 21 AS4 22 A + 24 VDC + 33 24 POT1 34 35 1 Potentiometer 36 5 7 8 3 4 10 38 9 A 24 VDC + + ZERO 11 1 32 17 18 2 CPT with isolated O/P 21 23 14 33 + - 32 + 4--20mA O/P 35 22 23 24 VDC EXTERNAL SUPPLY - IKPOT 16 15 - 35 A + 34 34 24 19 INDEPENDENT LIMIT SWITCH 20 0 Ref.Note 8 25 13 16 Ref.Note 3 10 14 Separate T/L 11 Combined T/L 2 4 9 12 4 5 49 50 Ref.Note 7 48 59 ILS3 60 ILS4 51 52 61 ILS5 53 Ref.Note 7 3 1 47 Back Wiring 28 58 ILS2 Back Wiring 27 1NO/1NC CHANGE OVER CONTACTS 31 15 3 46 30 32 T/LS OR TS 2 45 29 AS3 1 57 ILS1 26 54 62 ILS6 55 56 5 7 8 6 ILS1 ILS2 47 17 19 18 20 27 25 AS1 26 28 29 31 32 30 21 23 24 2NO+2NC POTENTIAL FREE CONTACTS 2NO+2NC POTENTIAL FREE CONTACTS - 35 SPAN 1NO+1NC POTENTIAL FREE CONTACTS 34 14 12 AS2 CPT EXT.SUPPLY 33 Contactless CPT 13 AS1 KMNPRSTU- POT2 37 Ref.Note 2 6 THREE THERMOSTATIN MOTOR ANTICLOCKWISE TO CLOSE EXTERNAL POSITIONER + 230V AC CPT EXTERNAL POSITIONER + LAMP FOR CLI ADDITIONAL SWITCH. 3 THERMOSTAT + L/R INDN. SWITCH EXTERNAL POSITIONER + 3 THERMOSTAT. THERMOSTAT ON HEATER 3 THERMOSTAT + L/R INDN S/W + THERMOSTAT ON HEATER. PLUG & SOCKET + ADDITIONAL SWITCH. 1K DUAL GANG POT + POSITIONER BLINKER INDICATION. POSITIONER + P/B COVER ASSY. POSITIONER. SPECIAL POT 15K 3 THERMISTOR WITH TRIPPING UNIT. SYNCROSET + P/B ASSY. Ref.Note 5 2 3ACDEFGHJ- Potentiometer 23 T/LS 0PQRSTUVWXYZ- 7 Potentiometer Fixed Resistor 16 AS3 6 Ref.Note 5 AS2 71 5 Ref.Note 6 1NO/1NC CHANGE OVER CONTACTS 6 4 AS1 41 2 5 Ref.Note 4 T/LS 5K6 Heater ANTI CLOCKWISE TO CLOSE BACK WIRING ON ILS 110VAC CPT ADDITIONAL SWITCHES IN S/ MECH 230VAC CPT THREE THERMOSTAT IN MOTOR THERMOSTAT ON HEATER 3 T.STAT ON MOTOR + ADDL. SWITCHES ADDITIONAL SWITCHES + T.STAT ON HEATER 3 T.STAT IN MOTOR + EXTERNAL POSITIONER P/B ASSY + POSITIONER SEP. 1NO+INC CHANGEOVER TQ/LT SWITCH ADDL. SW + 3 T.STAT ON MOTOR + 110VAC CPT ADDL. SW. + 3 T.STAT ON MOTOR INTEGRAL PLUG & SOCKET P/B ASSY. +3 T.STAT ON MOTOR ADL. CPT 1K POT 2NO2NC USED AS 1NO1NC IN ILS IK DUAL GANG POT P/B ASSY P/B ASSY. + LAMP FOR CLI P/B ASSY. + L/R INDN. SWITCH. 230VAC CPT + 3 T.STAT ON MOTOR 3 T.STAT ON MOTOR + LAMP FOR CLI 110VAC HEATER 45 46 48 55 53 54 56 57 59 60 58 49 51 52 50 22 NOTES : 1. Connect 1&2 in series with close contactor Connect 4&5 in series with open contactor 2. Connect 1&2 in series with open contactor Connect 5&6 in series with close contactor 3. Connect 1&2 in series with open contactor Connect 9&10 in series with close contactor 4. 100 ohms 1 watt suitable for 50V AC/DC operation. 61 62 63 53 54 55 56 57 58 59 60 43 44 45 46 47 48 49 50 51 52 33 34 35 36 37 38 39 40 41 42 22 23 24 25 26 27 28 29 30 31 11 12 13 14 18 19 20 1 2 3 4 8 9 5. C.P.T. connections shown for 2 wire systems, For 3 wire systems connect 34 to +ve of supply. 6. 1watt single or dual gang pot either 2.5k suitable for 50V AC/DC or 15k suitable for 110C AC/DC operation. Please specify pot. value while ordering. 21 7. Code Nos. 2&4 for back wiring. Terminals shown thus on Ref. Note. 7 are when Backwired. U 8. ILS are independent limit switches which can be set for any point of travel 15 16 5 6 V 64 17 7 W 32 10 E TERMINAL BLOCK LAYOUT Redefining Flow Control 9 Dimensional Drawings 143 448 182 317 152 492 540 Ø 610 Ø 416 Ø 457 FACE A 460 114 654 B 266 238 34 A Ă203 Ø 203 Ø 242 Ø 260 Actuator Size Output Speed (rpm) Motor Dimensions (mm) A B K4000 40 648 178 K5500 20, 30 648 178 40 756 235 20 648 178 30, 40 756 235 K7000 Bases: Note that F35E bases are integral within the above dimensions. F35AL and F40A are external bases which bolt to Face A. 10 Dimensional Drawings 143 448 182 317 492 152 540 Ø 610 Ø 416 FACE A A 460 114 Ø 203 654 B 238 34 Ø 457 Ø 242 Ø 203 343 Actuator Size Output Speed (rpm) 260 Motor Dimensions (mm) A B K4000 40 648 178 K5500 20, 30 648 178 40 756 235 20 648 178 30, 40 756 235 K7000 Bases: Note that F35E bases are integral within the above dimensions. F35AL and F40A are external bases which bolt to Face A. Redefining Flow Control 11 Redefining Flow Control www.rotork.com A full listing of our worldwide sales and service network is available on our website. Rotork plc Brassmill Lane, Bath, UK Rotork Controls (India) PVT. LTD., 28B Ambattur Industrial Estate (North), Chennai 600098 tel +44 (0)1225 733200 fax +44 (0)1225 333467 [email protected] tel +91 44 3955 5600 fax +91 44 2625 7108 [email protected] PUB009-001-00 Issue 03/15 Scan with your smart phone for more information on this product range As part of a process of on-going product development, Rotork reserves the right to amend and change specifications without prior notice. Published data may be subject to change. For the very latest version release, visit our website at www.rotork.com The name Rotork is a registered trademark. Rotork recognises all registered trademarks. Published and produced in the UK by Rotork Controls Limited. POWTG0315
Similar documents
in control
available service and support. The coming years would therefore witness a significant increase in the number of new Rotork offices, anticipating
More information