Ultraviolet Water Purification System
Transcription
Ultraviolet Water Purification System
Ultraviolet Water Purification System Basic The quality of drinking water can change with time and become contaminated with harmful bacteria. The Sterilight Silver™ system is a reliable, economical and chemical-free way to safeguard drinking water in any residential application. The Sterilight Silver™ system has been designed and tested to ensure quality drinking water is at everyone’s finger tips. Monitored Features of the Sterilight Silver UV purification system •Equipped to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, harmful bacteria like E.Coli and viruses not visible to the naked eye. •Specially designed and tested Sterilume™-EX lamps provide consistent and reliable ultraviolet output over the entire life of the lamp (9000 hours) to ensure continuous purification. •The system is easy to maintain and service. •The ultraviolet lamp can be changed without interrupting the water flow. •Built with a durable stainless steel chamber to prolong life and eliminate ultraviolet light degradation. •The Silver™ ICE power supply visually displays the remaining lamp life and will go into alarm if the lamp fails to notify the homeowner. Monitored systems also have the ability to read the percentage of UV output. •The power supply has a sealed case to prevent damage from accidental water intrusion and is fully CSA and CE compliant. •Monitored systems have a specialized 254nm UV intensity sensor which notifies homeowner of changes in UV performance. •Monitored systems have an optional solenoid valve which will stop the flow of water through the chamber should any changes in the UV performance falls below a safe level. SPECIFICATIONS MODEL S1Q-PA S2Q-PA/ SSM-17 S5Q-PA/ SSM-24 S8Q-PA/ SSM-37 S12Q-PA/ SSM-39 US Public Health (16 mJ/cm 2) 12.3 lpm (3.3 gpm) (0.7 m 3/hr) 15 lpm (4 gpm) (0.9 m 3/hr) 41.6 lpm (11 gpm) (2.5 m 3/hr) 75.7 lpm (20 gpm) (4.5 m 3/hr) 110 lpm (29 gpm) (6.6 m 3/hr) VIQUA Standard (30 mJ/cm 2) 7.5 lpm (2 gpm) (0.5 m 3/hr) 11 lpm (3 gpm) (0.7 m 3/hr) 22.7 lpm (6 gpm) (1.4 m 3/hr) 37.9 lpm (10 gpm) (2.3 m 3/hr) 57 lpm (15 gpm) (3.4 m 3/hr) NSF/EPA (40 mJ/cm 2) 5.5 lpm (1.5 gpm) (0.3 m 3/hr) 7.5 lpm (2 gpm) (0.5 m 3/hr) 17 lpm (4.5 gpm) (1.0 m 3/hr) 29.3 lpm (7.8 gpm) (1.8 m 3/hr) 42 lpm (11 gpm) (2.5 m 3/hr) Reactor 39.4 cm x 6.4 cm (15.5“ x 2.5“) 43.4 cm x 6.4 cm (17.1” x 2.5”) 56.1 cm x 6.4 cm (22.1” x 2.5“) 90.4 cm x 6.4 cm (35.6” x 2.5“) 95.3 cm x 8.9 cm (37.5” x 3.5“) Controller 21.1 cm x 8.1 cm x 6.4 cm (8.3” x 3.2“ x 2.5“) 21.1 cm x 8.1 cm x 6.4 cm (8.3” x 3.2“ x 2.5“) 21.1 cm x 8.1 cm x 6.4 cm (8.3” x 3.2“ x 2.5“) 21.1 cm x 8.1 cm x 6.4 cm (8.3” x 3.2“ x 2.5“) 21.1 cm x 8.1 cm x 6.4 cm (8.3” x 3.2“ x 2.5“) Inlet/Outlet Port Size 1/4“ MNPT 1/2“ MNPT 3/4“ MNPT 3/4“ MNPT Combo 3/4“ FNPT/1“MNPT Shipping Weight 2.7 kg (6 lbs.) 3.2 kg (7 lbs.) 3.6 kg (8 lbs.) 5.0 kg (11 lbs.) 5.9 kg (13 lbs.) Voltage 100-240V./50-60Hz 100-240V./50-60Hz 100-240V./50-60Hz 100-240V./50-60Hz 100-240V./50-60Hz Power Consumption 19 W 22 W 30 W 46 W 48 W Lamp Watts 14 W 17 W 25 W 37 W 39 W Maximum Operating Pressure 8.62 bar (125 psi) 8.62 bar (125 psi) 8.62 bar (125 psi) 8.62 bar (125 psi) 8.62 bar (125 psi) Ambient Water Temperature 2-40°C (36-104°F) 2-40°C (36-104°F) 2-40°C (36-104°F) 2-40°C (36-104°F) 2-40°C (36-104°F) Visual “Power-On” Yes Yes Yes Yes Yes Audible Lamp Failure Yes Yes Yes Yes Yes Lamp Replacement Reminder Yes Yes Yes Yes Yes Visual Lamp Life Remaining Yes Yes Yes Yes Yes FLOW RATES 1 DIMENSIONS ELECTRICAL Lamp Type Sterilume™- EX (standard-output) Total Running Time Chamber Material 2 Yes Yes Yes Yes Yes 304 SS 304 SS 304 SS 304 SS 304 SS SSM MODELS ONLY SSM-17 SSM-24 SSM-37 SSM-39 254nm UV Monitor Yes Yes Yes Yes Yes Yes Yes Yes Solenoid Output (solenoid not included) 4-20 mA Output 1 Yes (Optional 260134) Flow rates stated @ 95% UVT EOL 2 Yes (Optional 260134) Yes (Optional 260134) Yes (Optional 260134) 316 stainless steel available on request Replacement Parts S287RL – UV lamp for S1Q-PA/SSM-14 QS-463 – quartz sleev e for S5Q-PA/SSM-24 S330RL – UV lamp for S2Q-P A/SSM-17 QS-810 – quartz sleev e for S8Q-PA/SSM-37 S463RL – UV lamp for S5Q-P A/SSM-24 QS-012 – quartz sleev e for S12Q-PA/SSM-39 S810RL – UV lamp for S8Q-P A/SSM-37 410867 – o-ring for quartz slee ves S36RL – UV lamp for S1 2Q-PA/SSM-39 RN-001 – gland-nut for all sy stems QS-001 – quartz sleev e for S1Q-PA/SSM-14 QS-330 – quartz sleev e for S2Q-PA/SSM-17 BA-ICE-S – electronic ICE controller (100-240V./50-60Hz.) BA-ICE-SM – electronic ICE monitored controller (100-240V./50-60Hz.) 254NM-S2 – UV monitor assembly for Silv er “Plus” series (S12Q-PA) 254NM-S1 S t. 01543415200 • f. 01543415 900 – UV monitor assembly for Silv er “Plus” series (all except S12Q-PA) • [email protected] Ultraviolet Water Purification System The quality of drinking water can change with time and become contaminated with harmful bacteria. The Sterilight Cobalt™ Integrated Home System is a reliable, economical and chemical-free way to safeguard drinking water in any residential application. The Sterilight Cobalt™ has been designed and tested to ensure quality drinking water is at everyone’s finger tips. Features of the Sterilight Cobalt UV purification system •Equipped to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, harmful bacteria like E.Coli and viruses not visible to the naked eye. •The system is easy to maintain and service with easy lamp and cartridge replacement and quick disconnect fittings. •The ultraviolet lamp can be changed without interrupting the water flow and comes equipped with a connector that allows for easy removal of the lamp without any special tools. •Built with a durable stainless steel chamber to prolong life and eliminate ultraviolet light degradation. •Comes •Also equipped with a 5-micron sediment pre-filter to reduce particles in the water. comes equipped with a 5-micron carbon filter to reduce taste and odour of chlorine. •High flow polypropylene filter housings with 1“ full flow connections, available in either 10“ or 20“ versions. •Solid steel mounting bracket, compact design and easy to install. Basic Plus (with UV intensity monitor) SC-200-DWS11 – comes with two 10“ high flow filter housings SCM-200-DWS11 – comes with two 10“ high flow filter housings SC-320-DWS12 – comes with one 10“ and one 20“ high flow filter housings SCM-320-DWS12 – comes with one 10“ and one 20“ high flow filter housings SC-320-DWS22 – comes with two 20“ high flow filter housings SCM-320-DWS22 – comes with two 20“ high flow filter housings SPECIFICATIONS MODEL FLOW RATES SC-200-DWS11/ SCM-200-D WS11 SC-320-DWS12/ SCM-320-DWS12 SC-320-DWS22/ SCM-320-DWS22 30.3 lpm (8 gpm) (1.8 m3/hr) 49.2 lpm (13 gpm) (3.0 m3/hr) 49.2 lpm (13 gpm) (3.0 m3/hr) 22.7 lpm (6 gpm) (1.4 m3/hr) 37.8 lpm (10 gpm) (2.3 m3/hr) 37.8 lpm (10 gpm) (2.3 m3/hr) 59.7 cm x 20.3 cm x 56 cm (23.5” x 8” x 22”) 62 cm x 20.3 cm x 69.3 cm (24.4” x 8” x 27.3”) 62 cm x 20.3 cm x 69.3 cm (24.4” x 8” x 27.3”) 1 VIQUA Standard (30 mJ/cm NSF/EPA (40 mJ/cm 2 2 ) ) DIMENSIONS Overall Dimensions (Width x Depth x Height) Inlet/Outlet Port Size Combo- 3/4” FNPT & 1“ MNPT Shipping Weight 15.4 kg (34 lbs.) 17.7 kg (39 lbs.) 20 kg (44 lbs.) Voltage 100-240V./50-60Hz 100-240V./50-60Hz 100-240V./50-60Hz Power Consumption 35 W 42 W 42W Lamp Watts 27 W 34 W 34 W Maximum Operating Pressure 8.62 bar (125 psi) 8.62 bar (125 psi) 8.62 bar (125 psi) Ambient Water Temperature 2-40°C (36-104°F) 2-40°C (36-104°F) 2-40°C (36-104°F) ELECTRICAL Lamp Type Sterilume™- HO (high-output) Visual “Power-On” Yes Yes Yes Audible Lamp Failure Yes Yes Yes Lamp Replacement Reminder Yes Yes Yes Visual Lamp Life Remaining Yes Yes Yes Total Running Time Yes Yes Yes 304 SS 304 SS 304 SS Two 10” high flow Two 10” high flow Two 10” high flow SCM MODELS ONLY SCM-200 SCM-320 254nm UV Monitor Yes Yes Yes Yes Chamber Material 2 Filter Housing Solenoid Output (solenoid not included) 4-20 mA Output 1 Yes (Optional 260134) Flow Flow rates stated @ 95% UVT EOL Yes (Optional 260134) (flow rates based on UV system only, actual DWS system flow rates will vary and will be limited by the installed cartridge) Replacement Parts S200RL-HO – UV lamp for 200 systems QS-200 – quartz sleeve for 200 systems S320RL-HO – UV lamp for 320 systems QS-320 – quartz sleeve for 320 systems 410867 – o-ring for quartz sleeves RN-001 – gland-nut for all systems BA-ICE-C – controller (100-240V/50-60Hz) for SC models BA-ICE-CM – controller (100-240V/50-60Hz) for SCM models 254-C1 – UV monitor assembly for SCM models S t. 01543415200 • f. 01543415 900 • [email protected] Ultraviolet Water Purification System The latest offering extends the benefits offered to applications that don’t require a secondary carbon filter. The quality of drinking water can change with time and become contaminated with harmful bacteria. The Sterilight Cobalt™ Integrated Home System is a reliable, economical and chemical-free way to safeguard drinking water in any residential application. The Sterilight Cobalt™ has been designed and tested to ensure quality drinking water is at everyone’s finger tips. Extremely compact with unique features such as a reversible mounting bracket for easy, flexible installation, the SC200-DWS10, rated for 8 gpm flow, is the obvious choice for drinking water disinfection in your home. Features of the Sterilight Cobalt UV purification system • Equipped to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, harmful bacteria like E.Coli and viruses not visible to the naked eye. • The system is easy to maintain and service with easy lamp, sleeve, and filter cartridge replacement • The ultraviolet lamp can be changed without interrupting the water flow and comes equipped with a connector that allows for easy removal of the lamp without any special tools. • Built with a durable stainless steel chamber to prolong life and eliminate ultraviolet light degradation. • Comes equipped with a 5-micron sediment pre-filter to remove particulates. • Solid steel mounting bracket, compact design and easy to install. SPECIFICATIONS MODEL FLOW RATES Replacement Parts SC200-DWS10 1 S200RL-HO – UV lamp VIQUA Standard (30 mJ/cm NSF/EPA (40 mJ/cm 2 2 ) ) 30.3 lpm (8 gpm) (1.8 m 3 /hr) 22.7 lpm (6 gpm) (1.4 m 3 /hr) QS-200 – quartz sleeve S HO 200- QL – lamp /sleeve combination 410867 – o-ring DIMENSIONS Overall Dimensions (Width x Depth x Height) 42.0 cm x 25.3 cm x 44.3 cm (16.5” x 10” x 17.5”) Inlet/Outlet Port Size Combo- 3/4” FNPT & 1“ MNPT Shipping Weight 11.8 kg (26 lbs.) CMB-510-HF ELECTRICAL Voltage 100-240V./50-60Hz Power Consumption 35 W Lamp Watts 27 W Maximum Operating Pressure 8.62 bar (125 psi) Ambient Water Temperature 2-40°C (36-104°F) Lamp Type Sterilume™- HO (high-output) Visual “Power-On” Yes Audible Lamp Failure Yes Lamp Replacement Reminder Yes Visual Lamp Life Remaining Yes Total Running Time Yes Chamber Material 304 SS 2 Filter Housing 1 10” high flow (cartridge included) Flow Flow rates stated @ 95% UVT EOL S t. 01543415200 • f. 01543415 900 • [email protected]