Ultraviolet Water Purification System

Transcription

Ultraviolet Water Purification System
Ultraviolet Water Purification System
Basic
The quality of drinking water can change with time
and become contaminated with harmful bacteria.
The Sterilight Silver™ system is a reliable, economical
and chemical-free way to safeguard drinking water
in any residential application. The Sterilight Silver™
system has been designed and tested to ensure quality
drinking water is at everyone’s finger tips.
Monitored
Features of the Sterilight Silver UV purification system
•Equipped
to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia,
harmful bacteria like E.Coli and viruses not visible to the naked eye.
•Specially
designed and tested Sterilume™-EX lamps provide consistent and reliable
ultraviolet output over the entire life of the lamp (9000 hours) to ensure continuous
purification.
•The
system is easy to maintain and service.
•The
ultraviolet lamp can be changed without interrupting the water flow.
•Built
with a durable stainless steel chamber to prolong life and eliminate ultraviolet light
degradation.
•The
Silver™ ICE power supply visually displays the remaining lamp life and will go into
alarm if the lamp fails to notify the homeowner. Monitored systems also have the ability to
read the percentage of UV output.
•The
power supply has a sealed case to prevent damage from accidental water intrusion and
is fully CSA and CE compliant.
•Monitored
systems have a specialized 254nm UV intensity sensor which notifies
homeowner of changes in UV performance.
•Monitored
systems have an optional solenoid valve which will stop the flow of water
through the chamber should any changes in the UV performance falls below a safe level.
SPECIFICATIONS
MODEL
S1Q-PA
S2Q-PA/
SSM-17
S5Q-PA/
SSM-24
S8Q-PA/
SSM-37
S12Q-PA/
SSM-39
US Public Health
(16 mJ/cm 2)
12.3 lpm (3.3 gpm)
(0.7 m 3/hr)
15 lpm (4 gpm)
(0.9 m 3/hr)
41.6 lpm (11 gpm)
(2.5 m 3/hr)
75.7 lpm (20 gpm)
(4.5 m 3/hr)
110 lpm (29 gpm)
(6.6 m 3/hr)
VIQUA Standard
(30 mJ/cm 2)
7.5 lpm (2 gpm)
(0.5 m 3/hr)
11 lpm (3 gpm)
(0.7 m 3/hr)
22.7 lpm (6 gpm)
(1.4 m 3/hr)
37.9 lpm (10 gpm)
(2.3 m 3/hr)
57 lpm (15 gpm)
(3.4 m 3/hr)
NSF/EPA
(40 mJ/cm 2)
5.5 lpm (1.5 gpm)
(0.3 m 3/hr)
7.5 lpm (2 gpm)
(0.5 m 3/hr)
17 lpm (4.5 gpm)
(1.0 m 3/hr)
29.3 lpm (7.8 gpm)
(1.8 m 3/hr)
42 lpm (11 gpm)
(2.5 m 3/hr)
Reactor
39.4 cm x 6.4 cm
(15.5“ x 2.5“)
43.4 cm x 6.4 cm
(17.1” x 2.5”)
56.1 cm x 6.4 cm
(22.1” x 2.5“)
90.4 cm x 6.4 cm
(35.6” x 2.5“)
95.3 cm x 8.9 cm
(37.5” x 3.5“)
Controller
21.1 cm x 8.1 cm x 6.4 cm
(8.3” x 3.2“ x 2.5“)
21.1 cm x 8.1 cm x 6.4 cm
(8.3” x 3.2“ x 2.5“)
21.1 cm x 8.1 cm x 6.4 cm
(8.3” x 3.2“ x 2.5“)
21.1 cm x 8.1 cm x 6.4 cm
(8.3” x 3.2“ x 2.5“)
21.1 cm x 8.1 cm x 6.4 cm
(8.3” x 3.2“ x 2.5“)
Inlet/Outlet Port Size
1/4“ MNPT
1/2“ MNPT
3/4“ MNPT
3/4“ MNPT
Combo
3/4“ FNPT/1“MNPT
Shipping Weight
2.7 kg (6 lbs.)
3.2 kg (7 lbs.)
3.6 kg (8 lbs.)
5.0 kg (11 lbs.)
5.9 kg (13 lbs.)
Voltage
100-240V./50-60Hz
100-240V./50-60Hz
100-240V./50-60Hz
100-240V./50-60Hz
100-240V./50-60Hz
Power Consumption
19 W
22 W
30 W
46 W
48 W
Lamp Watts
14 W
17 W
25 W
37 W
39 W
Maximum Operating Pressure
8.62 bar (125 psi)
8.62 bar (125 psi)
8.62 bar (125 psi)
8.62 bar (125 psi)
8.62 bar (125 psi)
Ambient Water Temperature
2-40°C (36-104°F)
2-40°C (36-104°F)
2-40°C (36-104°F)
2-40°C (36-104°F)
2-40°C (36-104°F)
Visual “Power-On”
Yes
Yes
Yes
Yes
Yes
Audible Lamp Failure
Yes
Yes
Yes
Yes
Yes
Lamp Replacement Reminder
Yes
Yes
Yes
Yes
Yes
Visual Lamp Life Remaining
Yes
Yes
Yes
Yes
Yes
FLOW RATES
1
DIMENSIONS
ELECTRICAL
Lamp Type
Sterilume™- EX (standard-output)
Total Running Time
Chamber Material
2
Yes
Yes
Yes
Yes
Yes
304 SS
304 SS
304 SS
304 SS
304 SS
SSM MODELS ONLY
SSM-17
SSM-24
SSM-37
SSM-39
254nm UV Monitor
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Solenoid Output
(solenoid not included)
4-20 mA Output
1
Yes (Optional 260134)
Flow rates stated @ 95% UVT EOL
2
Yes (Optional 260134)
Yes (Optional 260134)
Yes (Optional 260134)
316 stainless steel available on request
Replacement Parts
S287RL – UV lamp for S1Q-PA/SSM-14
QS-463
– quartz sleev e for S5Q-PA/SSM-24
S330RL
– UV lamp for S2Q-P A/SSM-17
QS-810
– quartz sleev e for S8Q-PA/SSM-37
S463RL
– UV lamp for S5Q-P A/SSM-24
QS-012
– quartz sleev e for S12Q-PA/SSM-39
S810RL
– UV lamp for S8Q-P A/SSM-37
410867
– o-ring for quartz slee ves
S36RL
– UV lamp for S1 2Q-PA/SSM-39
RN-001
– gland-nut for all sy stems
QS-001
– quartz sleev e for S1Q-PA/SSM-14
QS-330
– quartz sleev e for S2Q-PA/SSM-17
BA-ICE-S
– electronic ICE controller
(100-240V./50-60Hz.)
BA-ICE-SM
– electronic ICE monitored controller
(100-240V./50-60Hz.)
254NM-S2
– UV monitor assembly for Silv er “Plus” series
(S12Q-PA)
254NM-S1
S
t. 01543415200
•
f. 01543415 900
– UV monitor assembly for Silv er “Plus”
series (all except S12Q-PA)
• [email protected]
Ultraviolet Water Purification System
The quality of drinking water can change with time
and become contaminated with harmful bacteria. The
Sterilight Cobalt™ Integrated Home System is a reliable,
economical and chemical-free way to safeguard drinking
water in any residential application. The Sterilight Cobalt™
has been designed and tested to ensure quality drinking
water is at everyone’s finger tips.
Features of the Sterilight Cobalt UV purification system
•Equipped
to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia,
harmful bacteria like E.Coli and viruses not visible to the naked eye.
•The
system is easy to maintain and service with easy lamp and cartridge replacement
and quick disconnect fittings.
•The
ultraviolet lamp can be changed without interrupting the water flow and comes equipped
with a connector that allows for easy removal of the lamp without any special tools.
•Built
with a durable stainless steel chamber to prolong life and eliminate ultraviolet
light degradation.
•Comes
•Also
equipped with a 5-micron sediment pre-filter to reduce particles in the water.
comes equipped with a 5-micron carbon filter to reduce taste and odour of chlorine.
•High
flow polypropylene filter housings with 1“ full flow connections, available in either 10“
or 20“ versions.
•Solid
steel mounting bracket, compact design and easy to install.
Basic
Plus (with UV intensity monitor)
SC-200-DWS11 – comes with two 10“ high flow filter housings
SCM-200-DWS11 – comes with two 10“ high flow filter housings
SC-320-DWS12 – comes with one 10“ and one 20“ high flow filter housings
SCM-320-DWS12 – comes with one 10“ and one 20“ high flow filter housings
SC-320-DWS22 – comes with two 20“ high flow filter housings
SCM-320-DWS22 – comes with two 20“ high flow filter housings
SPECIFICATIONS
MODEL
FLOW RATES
SC-200-DWS11/
SCM-200-D WS11
SC-320-DWS12/
SCM-320-DWS12
SC-320-DWS22/
SCM-320-DWS22
30.3 lpm (8 gpm) (1.8 m3/hr)
49.2 lpm (13 gpm) (3.0 m3/hr)
49.2 lpm (13 gpm) (3.0 m3/hr)
22.7 lpm (6 gpm) (1.4 m3/hr)
37.8 lpm (10 gpm) (2.3 m3/hr)
37.8 lpm (10 gpm) (2.3 m3/hr)
59.7 cm x 20.3 cm x 56 cm
(23.5” x 8” x 22”)
62 cm x 20.3 cm x 69.3 cm
(24.4” x 8” x 27.3”)
62 cm x 20.3 cm x 69.3 cm
(24.4” x 8” x 27.3”)
1
VIQUA Standard (30 mJ/cm
NSF/EPA (40 mJ/cm
2
2
)
)
DIMENSIONS
Overall Dimensions
(Width x Depth x Height)
Inlet/Outlet Port Size
Combo- 3/4” FNPT & 1“ MNPT
Shipping Weight
15.4 kg (34 lbs.)
17.7 kg (39 lbs.)
20 kg (44 lbs.)
Voltage
100-240V./50-60Hz
100-240V./50-60Hz
100-240V./50-60Hz
Power Consumption
35 W
42 W
42W
Lamp Watts
27 W
34 W
34 W
Maximum Operating Pressure
8.62 bar (125 psi)
8.62 bar (125 psi)
8.62 bar (125 psi)
Ambient Water Temperature
2-40°C (36-104°F)
2-40°C (36-104°F)
2-40°C (36-104°F)
ELECTRICAL
Lamp Type
Sterilume™- HO (high-output)
Visual “Power-On”
Yes
Yes
Yes
Audible Lamp Failure
Yes
Yes
Yes
Lamp Replacement Reminder
Yes
Yes
Yes
Visual Lamp Life Remaining
Yes
Yes
Yes
Total Running Time
Yes
Yes
Yes
304 SS
304 SS
304 SS
Two 10” high flow
Two 10” high flow
Two 10” high flow
SCM MODELS ONLY
SCM-200
SCM-320
254nm UV Monitor
Yes
Yes
Yes
Yes
Chamber Material
2
Filter Housing
Solenoid Output
(solenoid not included)
4-20 mA Output
1
Yes (Optional 260134)
Flow Flow rates stated @ 95% UVT EOL
Yes (Optional 260134)
(flow rates based on UV system only, actual DWS system flow rates will vary and will be limited by the installed cartridge)
Replacement Parts
S200RL-HO – UV lamp for 200 systems
QS-200 – quartz sleeve for 200 systems
S320RL-HO – UV lamp for 320 systems
QS-320 – quartz sleeve for 320 systems
410867 – o-ring for quartz sleeves
RN-001 – gland-nut for all systems
BA-ICE-C – controller (100-240V/50-60Hz) for SC models
BA-ICE-CM – controller (100-240V/50-60Hz) for SCM models
254-C1 – UV monitor assembly for SCM models
S
t. 01543415200
•
f. 01543415 900
• [email protected]
Ultraviolet Water Purification System
The latest offering extends the benefits
offered to applications that don’t require
a secondary carbon filter.
The quality of drinking water can change with time
and become contaminated with harmful bacteria.
The Sterilight Cobalt™ Integrated Home System is a
reliable, economical and chemical-free way to safeguard
drinking water in any residential application. The Sterilight
Cobalt™ has been designed and tested to ensure quality
drinking water is at everyone’s finger tips.
Extremely compact with unique features such as
a reversible mounting bracket for easy, flexible
installation, the SC200-DWS10, rated for 8 gpm flow,
is the obvious choice for drinking water disinfection in
your home.
Features of the Sterilight Cobalt UV purification system
•
Equipped to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia,
harmful bacteria like E.Coli and viruses not visible to the naked eye.
•
The system is easy to maintain and service with easy lamp, sleeve, and filter cartridge
replacement
•
The ultraviolet lamp can be changed without interrupting the water flow and comes equipped
with a connector that allows for easy removal of the lamp without any special tools.
•
Built with a durable stainless steel chamber to prolong life and eliminate ultraviolet
light degradation.
•
Comes equipped with a 5-micron sediment pre-filter to remove particulates.
•
Solid steel mounting bracket, compact design and easy to install.
SPECIFICATIONS
MODEL
FLOW RATES
Replacement Parts
SC200-DWS10
1
S200RL-HO – UV lamp
VIQUA Standard (30 mJ/cm
NSF/EPA (40 mJ/cm
2
2
)
)
30.3 lpm (8 gpm) (1.8 m
3
/hr)
22.7 lpm (6 gpm) (1.4 m
3
/hr)
QS-200 – quartz sleeve
S HO 200- QL – lamp /sleeve combination
410867 – o-ring
DIMENSIONS
Overall Dimensions
(Width x Depth x Height)
42.0 cm x 25.3 cm x 44.3 cm
(16.5” x 10” x 17.5”)
Inlet/Outlet Port Size
Combo- 3/4” FNPT & 1“ MNPT
Shipping Weight
11.8 kg (26 lbs.)
CMB-510-HF
ELECTRICAL
Voltage
100-240V./50-60Hz
Power Consumption
35 W
Lamp Watts
27 W
Maximum Operating Pressure
8.62 bar (125 psi)
Ambient Water Temperature
2-40°C (36-104°F)
Lamp Type
Sterilume™- HO (high-output)
Visual “Power-On”
Yes
Audible Lamp Failure
Yes
Lamp Replacement Reminder
Yes
Visual Lamp Life Remaining
Yes
Total Running Time
Yes
Chamber Material
304 SS
2
Filter Housing
1
10” high flow
(cartridge included)
Flow Flow rates stated @ 95% UVT EOL
S
t. 01543415200
•
f. 01543415 900
• [email protected]