AWP Super Series from SN 3896-101 to 3801-99999 (PN
Transcription
AWP Super Series from SN 3896-101 to 3801-99999 (PN
Introduction First Edition • Second Printing Important Read, understand and obey the safety rules and operating instructions in the Genie AWP Super Series and IWP Super Series Operator's Manual before attempting any maintenance or repair procedure. This manual provides detailed scheduled maintenance information for the machine owner and user. It also provides troubleshooting and repair procedures for qualified service professionals. Basic mechanical, hydraulic and electrical skills are required to perform most procedures. However, several procedures require specialized skills, tools, lifting equipment and a suitable workshop. In these instances, we strongly recommend that maintenance and repair be performed at an authorized Genie dealer service center. Compliance Machine Classification Group A/Type 1 as defined by ISO 16368 Machine Design Life Unrestricted with proper opeation, inspection and scheduled maintenance. Technical Publications Genie Industries has endeavored to deliver the highest degree of accuracy possible. However, continuous improvement of our products is a Genie policy. Therefore, product specifications are subject to change without notice. Readers are encouraged to notify Genie of errors and send in suggestions for improvement. All communications will be carefully considered for future printings of this and all other manuals. Copyright © 1996 by Genie Industries First Edition: Second Printing, December 2001 "Genie" is a registered trademarks of Genie Industries in the USA and many other countries. Printed on recycled paper Contact Us: Printed in U.S.A. www.genieindustries.com e-mail: [email protected] ii Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 1 • Safety Rules Safety Rules Danger Failure to obey the instructions and safety rules in this manual and the appropriate Operator's Manual on your machine will result in death or serious injury. Many of the hazards identified in the operator’s manuals are also safety hazards when maintenance and repair procedures are performed. Do Not Perform Maintenance Unless: You are trained and qualified to perform maintenance on this machine. You read, understand and obey: - manufacturer’s instructions and safety rules - employer’s safety rules and worksite regulations - applicable governmental regulations You have the appropriate tools, lifting equipment and a suitable workshop. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series iii Introduction First Edition • Second Printing SAFETY RULES Personal Safety Workplace Safety Any person working on or around a machine must be aware of all known safety hazards. Personal safety and the continued safe operation of the machine should be your number one priority. Be sure to keep sparks, flames and lighted tobacco away from flammable and combustible materials like battery gases. Always have an approved fire extinguisher within easy reach. Read each procedure thoroughly. This manual and the decals on the machine use signal words to identify the following: Safety alert symbol–used to alert personenel to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may cause minor or moderate injury. Be sure that all tools and working areas are properly maintained and ready for use. Keep work surfaces clean and free of debris that could get into machine components and cause damage. Be sure any forklift, overhead crane or other lifting or supporting device is fully capable of supporting and stabilizing the weight to be lifted. Use only chains or straps that are in good condition and of ample capacity. Be sure that fasteners intended for one-time use (i.e., cotter pins and selflocking nuts) are not reused. These components may fail if they are used a second time. Be sure to properly dispose of old oil or other fluids. Use an approved container. Please environmentally safe. Be sure that your workshop or work area is properly ventilated and well lit. Indicates a potentially hazardous situation which, if not avoided, may result in property damage. Be sure to wear protective eye wear and other protective clothing if the situation warrants it. Be aware of potential crushing hazards such as moving parts, free-swinging or unsecured components when lifting or placing loads. Always wear approved steel-toed shoes. iv Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Table of Contents Introduction Important Information ...................................................................................................... ii Section One Safety Rules General Safety Rules .................................................................................................... iii Section Two Specifications AWP Super Series Standard Base Models ............................................................... 2 - 1 AWP Super Series Narrow Base Models .................................................................. 2 - 3 AWP Super Series Rough Terrain Base Models ...................................................... 2 - 4 IWP-20S ................................................................................................................... 2 - 5 IWP-25S ................................................................................................................... 2 - 5 IWP-30S ................................................................................................................... 2 - 5 Performance Specifications ...................................................................................... 2 - 6 Hydraulic Hose and Fitting Torque Specification ...................................................... 2 - 7 Section Three Theory of Operation Theory of Operation .................................................................................................. 3 - 1 Part No. 38139 Genie AWP Super Series and Genie IWP Super Series v First Edition • Second Printing TABLE OF CONTENTS Section Four Scheduled Maintenance Procedures Introduction ............................................................................................................... 4 - 1 Pre-delivery Preparation Report ............................................................................... 4 - 3 Maintenance Inspection Report ................................................................................ 4 - 5 A-1 Inspect the Operator's and Safety Manuals .................................................... 4 - 6 A-2 Inspect the Decals and Placards ..................................................................... 4 - 7 A-3 Inspect for Damage and Loose or Missing Parts ............................................. 4 - 7 A-4 Check for Hydraulic Leaks .............................................................................. 4 - 8 A-5 Check the Hydraulic Oil Level ......................................................................... 4 - 9 A-6 Test the Base Operation - IWPS Models ........................................................ 4 - 9 A-7 Check the Auxiliary Platform Lowering Operation ......................................... 4 - 10 A-8 Check the Manual Platform Lowering Operation ........................................... 4 - 10 A-9 Inspect the Battery and Battery Charger - DC Models .................................. 4 - 11 A-10 Inspect the Columns for Damage .................................................................. 4 - 11 A-11 Check the Sequencing Cables ...................................................................... 4 - 12 A-12 Check the Interlock System for Proper Operation ......................................... 4 - 12 A-13 Test the Power and Function Controls .......................................................... 4 - 13 A-14 Inspect the Lifting Chains and Idler Wheels .................................................. 4 - 14 A-15 Inspect the Breather Cap .............................................................................. 4 - 15 A-16 Check the Tire Pressure - AWPS Models with Rough Terrain Base Option .. 4 - 15 A-17 Check the Air Supply Lubricator Oil Level - Air Models ................................. 4 - 15 A-18 Check the Air Supply Lubricator Canister Drip Rate - Air Models .................. 4 - 16 A-19 Check the Air Filter/Regulator Canister - Air Models ..................................... 4 - 16 vi Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing TABLE OF CONTENTS Section Four Scheduled Maintenance Procedures, continued B-1 Inspect the Electrical Wiring .......................................................................... 4 - 17 B-2 Inspect All Welds .......................................................................................... 4 - 18 B-3 Test the Tilt-back Operation (if equipped) ..................................................... 4 - 18 B-4 Check the Lifting Chain Adjustments ............................................................ 4 - 19 B-5 Check the Battery - DC Models ..................................................................... 4 - 20 B-6 Clean and Lubricate the Columns ................................................................. 4 - 21 B-7 Test the Lifting Capacity ................................................................................ 4 - 22 B-8 Adjust the Sequencing Cables ...................................................................... 4 - 22 B-9 Inspect for Proper Outrigger Length - AWPS Models .................................... 4 - 24 B-10 Inspect and Lubricate the Outrigger Leveling Jack Footpads AWPS Models ............................................................................................... 4 - 25 B-11 Test the Level Sensing Operation - IWPS Models ........................................ 4 - 26 B-12 Check the Chain Adjustment, IWP-20S Models with Outreach Option .......... 4 - 27 Part No. 38139 C-1 Inspect and Lubricate the Casters and Wheels ............................................. 4 - 28 C-2 Inspect the Mast Assembly for Wear ............................................................ 4 - 28 C-3 Inspect and Lubricate the Lifting Chains ....................................................... 4 - 30 C-4 Replace the Hydraulic Oil .............................................................................. 4 - 30 C-5 Replace the Auxiliary Platform Lowering Batteries ........................................ 4 - 32 C-6 Remove and Inspect the Lifting Chains ......................................................... 4 - 32 Genie AWP Super Series and Genie IWP Super Series vii First Edition • Second Printing TABLE OF CONTENTS Section Five Troubleshooting Flow Charts Introduction ............................................................................................................... 5 - 1 viii 1 Power Light Will Not Turn On - AC Models ..................................................... 5 - 3 2 Power Light Will Not Turn On - DC Models ..................................................... 5 - 5 3 Interlock Lights Will Not Turn On - AWPS AC and DC Models ....................... 5 - 6 4 Foot Pad Interlock Lights Will Not Turn On - IWPS Models ............................ 5 - 7 5 Level Sensor Interlock Lights Will Not Turn On - IWPS Models ...................... 5 - 8 6 Platform Up Function Inoperative - AC Models ............................................. 5 - 10 7 Platform Up Function Inoperative, But Power Unit Runs - AC Models .......... 5 - 13 8 Platform Up Function Inoperative - DC Models ............................................. 5 - 15 9 Platform Up Function Inoperative, But Power Unit Runs - DC Models .......... 5 - 17 10 Platform Down Inoperative ............................................................................ 5 - 19 11 Base Will Not Raise With Foot Pump - IWPS Models ................................... 5 - 20 12 Base Will Raise, But Will Not Hold In Up Position - IWPS Models ................ 5 - 21 13 Base Will Not Lower - IWPS Models ............................................................. 5 - 22 14 Platform Will Not Hold In Up Position ............................................................ 5 - 23 15 Power Unit Will Not Lift Rated Load .............................................................. 5 - 24 16 Auxiliary Platform Lowering Will Not Operate ................................................ 5 - 25 17 Power Wheel Assist Will Not Operate IWPS Models with Power Wheel Assist ........................................................ 5 - 26 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing TABLE OF CONTENTS Section Six Repair Procedures Introduction ............................................................................................................... 6 - 1 Base Assembly 1-1 Interlocks ........................................................................................................ 6 - 2 1-2 Base Components - IWPS Models .................................................................. 6 - 3 1-3 Foot Pump Manifold Components - IWPS Models .......................................... 6 - 7 1-4 Power Wheel Assist Manifold Components - IWPS Models (before serial number 4097-991) ..................................................................... 6 - 8 1-5 Power Wheel Assist Manifold Components - IWPS Models (from serial number 4097-991 to 4099-2532) .................................................. 6 - 9 1-6 Power Wheel Assist Manifold Components - IWPS Models (after serial number 4099-2532) .................................................................... 6 - 10 Ground Control Box 2-1 How to Test the Transformer - AC Models .................................................... 6 - 12 2-2 How to Test the AC Contactor - AC Models .................................................. 6 - 13 Hydraulic Power Unit Part No. 38139 3-1 Hydraulic Power Unit Components - AC Models ........................................... 6 - 14 3-2 Hydraulic Power Unit Components - DC Models ........................................... 6 - 16 3-3 Hydraulic Power Unit Components - Air Powered Models ............................ 6 - 18 3-4 Hydraulic Power Unit .................................................................................... 6 - 20 3-5 Hydraulic Pump ............................................................................................ 6 - 22 3-6 Valve Adjustment .......................................................................................... 6 - 23 3-7 How to Test the Motor Start Solenoid - DC Models ....................................... 6 - 24 Genie AWP Super Series and Genie IWP Super Series ix First Edition • Second Printing TABLE OF CONTENTS Section Six Repair Procedures, continued Power Pack 4-1 Power Pack ................................................................................................... 6 - 25 Mast Components Mast Illustrations ........................................................................................... 6 - 26 5-1 Lift Cylinder ................................................................................................... 6 - 27 5-2 Mast Assembly ............................................................................................. 6 - 28 5-3 Glide Pads .................................................................................................... 6 - 33 5-4 Lifting Chains ................................................................................................ 6 - 34 Tilt-back Frame, AWP-36S and 40S Models 6-1 Tilt-back Frame ............................................................................................. 6 - 38 Platform x 7-1 Platforms ....................................................................................................... 6 - 40 7-2 Platform Control Box ..................................................................................... 6 - 41 7-3 Platform Outreach Chain ............................................................................... 6 - 42 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing TABLE OF CONTENTS Section Seven Schematics Introduction ............................................................................................................... 7 - 1 Electrical Components .............................................................................................. 7 - 2 Electrical Symbols Legend ....................................................................................... 7 - 3 Electrical Schematic - AWP Super Series DC Models (from serial number 3896-101 to 3896-300) ............................................................. 7 - 5 Electrical Schematic - AWP Super Series DC Models (from serial number 3896-301 to 3896-430) ............................................................. 7 - 6 Electrical Schematic - AWP Super Series DC Models (from serial number 3896-301 to 3896-431 to AWP07-54898) ................................. 7 - 7 Electrical Schematic - AWP Super Series DC Models Standard Base (after serial number AWP07-54898) ......................................................................... 7 - 8 Electrical Schematic - AWP Super Series DC Models Narrow Base (after serial number AWP07-54898) ......................................................................... 7 - 9 Electrical Schematic - AWP Super Series DC CE Models (from serial number 3896-432 to AWP07-54898) ................................................... 7 - 10 Electrical Schematic - AWP Super Series DC CE Models Standard Base (after serial number AWP07-54898) ....................................................................... 7 - 11 Electrical Schematic - AWP Super Series DC CE Models Narrow Base (after serial number AWP07-54898) ....................................................................... 7 - 12 Electrical Schematic - AWP Super Series DC TUV Models (after serial number 3896-430) ............................................................................... 7 - 13 Electrical Schematic - AWP Super Series AC Models (from serial number 3894-103 to 3896-303) ........................................................... 7 - 14 Electrical Schematic - AWP Super Series AC Models (from serial number 3894-304 to 3896-450) ........................................................... 7 - 15 Electrical Schematic - AWP Super Series AC Models (from serial number 3894-451 to AWP07-54898) ................................................... 7 - 16 Electrical Schematic - AWP Super Series AC Models Standard Base (from serial number AWP07-54898 to AWP07-57594) ........................................... 7 - 17 Electrical Schematic - AWP Super Series AC Models Narrow Base (from serial number AWP07-54898 to AWP07-57594) ........................................... 7 - 18 Electrical Schematic - AWP Super Series AC Models Standard Base (after serial number AWP07-57594) ....................................................................... 7 - 19 Electrical Schematic - AWP Super Series AC Models Narrow Base (after serial number AWP07-57594) ....................................................................... 7 - 20 Part No. 38139 Genie AWP Super Series and Genie IWP Super Series xi First Edition • Second Printing TABLE OF CONTENTS Section Seven Schematics, continued Electrical Schematic - AWP Super Series AC CE Models (from serial number 3896-451 to AWP07-54898) ................................................... 7 - 21 Electrical Schematic - AWP Super Series AC CE Models Standard Base (from serial number AWP07-54899 to AWP07-57594) ........................................... 7 - 22 Electrical Schematic - AWP Super Series AC CE Models Narrow Base (from serial number AWP07-54899 to AWP07-57594) ........................................... 7 - 23 Electrical Schematic - AWP Super Series AC CE Models Standard Base (after serial number AWP07-57594) ....................................................................... 7 - 24 Electrical Schematic - AWP Super Series AC CE Models Narrow Base (after serial number AWP07-57594) ....................................................................... 7 - 25 Electrical Schematic - AWP Super Series AC TUV Models (after serial number 3896-460) ............................................................................... 7 - 26 Electrical Schematic - IWP Super Series DC Models (from serial number 4096-101 to 4096-287) ........................................................... 7 - 27 Electrical Schematic - IWP Super Series DC Models (from serial number 4096-288 to 4096-341) ........................................................... 7 - 28 Electrical Schematic - IWP Super Series DC Models (from serial number 4096-342 to IWP07-7065) ....................................................... 7 - 29 Electrical Schematic - IWP Super Series DC Models (after serial number IWP07-7065) ........................................................................... 7 - 30 Electrical Schematic - IWP Super Series DC Models with Power Assist ................ 7 - 31 Electrical Schematic - IWP Super Series DC Models with Power Assist (Directional Valve Coils Powering Function Manifold) ............................................. 7 - 32 Electrical Schematic - IWP Super Series DC TUV Models ..................................... 7 - 33 Electrical Schematic - IWP Super Series DC TUV Models with Outreach .............. 7 - 34 Electrical Schematic - IWP Super Series DC TUV Models with Power Assist ........ 7 - 35 Electrical Schematic - IWP Super Series DC TUV Models with Power Assist and Outreach ................................................................ 7 - 36 Electrical Schematic - IWP Super Series DC TUV Models with Power Assist (Directional Valve Coils Powering Function Manifold) ............................................. 7 - 37 xii Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section Seven Schematics, continued Electrical Schematic - IWP Super Series AC Models (from serial number 4096-105 to 4096-285) ........................................................... 7 - 38 Electrical Schematic - IWP Super Series AC Models (from serial number 4096-286 to 4096-355) ........................................................... 7 - 39 Electrical Schematic - IWP Super Series AC Models (from serial number 4096-356 to IWP07-7065) ....................................................... 7 - 40 Electrical Schematic - IWP Super Series AC Models (from serial number IWP07-7066 to IWP07-57594) ................................................ 7 - 41 Electrical Schematic - IWP Super Series AC Models (after serial number IWP07-57594) ......................................................................... 7 - 42 Electrical Schematic - IWP Super Series AC TUV (Models with Base-mounted Junction Box) ............................................................. 7 - 43 Electrical Schematic - IWP Super Series AC TUV (Models without Base-mounted Junction Box) ........................................................ 7 - 44 Electrical Schematic - IWP Super Series AC TUV Models with Outreach .............. 7 - 45 Hydraulic Schematic Legend .................................................................................. 7 - 46 Hydraulic Schematic - AWP Super Series Models .................................................. 7 - 47 Hydraulic/Pneumatic Schematic - AWP Super Series Models ................................ 7 - 48 Hydraulic Schematic - IWP Super Series Models without Power Assist ................. 7 - 49 Hydraulic Schematic - IWP Super Series Models with Power Assist ...................... 7 - 50 Hydraulic Schematic - IWP Super Series Models with Power Assist and Brakes ... 7 - 51 Hydraulic Schematic - IWP Super Series (Models with Power Assist, Brakes and Cross Port Relief) ..................................... 7 - 52 Part No. 38139 Genie AWP Super Series and Genie IWP Super Series xiii First Edition • Second Printing This page intentionally left blank. Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 2 • Specifications Specifications Model Standard Base Height, working maximum AWP-15S AWP-20S AWP-25S 21 ft 4 in 6.5 m 15 ft 4 in 4.7 m 350 lbs 159 kg 300 lbs 136 kg 26 ft 1 in 8.0 m 20 ft 1 in 6.1 m 350 lbs 159 kg 300 lbs 136 kg 30 ft 9 in 9.4 m 24 ft 9 in 7.6 m 350 lbs 159 kg 300 lbs 136 kg 12V 110V or 220V 100 psi / 6.9 bar -20°F to 135°F -29°C to 57°C 12V 110V or 220V 100 psi / 6.9 bar -20°F to 135°F -29°C to 57°C 764 / 674 lbs 347 / 306 kg 78 in 198 cm 29 in 73.6 cm 817 / 727 lbs 371 / 330 kg 78 in 198 cm 29 in 73.6 cm 46 in 46 in 117 cm 117 cm Outrigger footprint 603/4 x 523/4 in 603/4 x 523/4 in (l x w) Domestic 154 x 134 cm 154 x 134 cm 3 3 Outrigger footprint 60 /4 x 52 /4 in 691/4 x 611/4 in (l x w) CSA 154 x 134 cm 175.6 x 155.3 cm Outrigger footprint 603/4 x 523/4 in 603/4 x 523/4 in (l x w) CE Indoor 154 x 134 cm 154 x 134 cm Outrigger footprint 691/4 x 611/4 in 831/4 x 751/4 in (l x w) CE Outdoor 175.6 x 155.3 cm 211.5 x 191.2 cm Corner access/wall access* 153/4 / 8 in 141/2 / 51/2 in Domestic 39.7 / 20.3 cm 36.9 / 7.4 cm Corner access/wall access* 153/4 / 8 in 201/4 / 93/4 in CSA 39.7 / 20.3 cm 51.2 / 24.5 cm Corner access/wall access* 153/4 / 8 in 141/2 / 51/2 in CE Indoor 39.7 / 20.3 cm 36.9 / 7.4 cm 1 1 Corner access/wall access* 21 /2 / 12 /4 in 30 / 163/4 in CE Outdoor 54.6 / 30.8 cm 76 / 42.4 cm * Corner of platform top rail to corner of wall with ability to rotate leveling jack. 46 in 117 cm 603/4 x 523/4 in 154 x 134 cm 831/2 x 751/2 in 212 x 191 cm 691/4 x 611/4 in 175.6 x 155.3 cm 89 x 81 in 225.9 x 205.6 cm 14 / 3 in 35.1 / 7.4 cm 283/4 / 141/4 in 72.6 / 36.2 cm 191/4 / 71/4 in 48.6 / 18.2 cm 321/2 / 17 in 82.5 / 43.4 cm Height, platform maximum Lift capacity all models except Canada Lift capacity models sold in Canada only Power source DC model 12V AC model 110V or 220V Air motor 100 psi / 6.9 bar Ambient Operating -20°F to 135°F Temperature -29°C to 57°C Machine weight (DC / AC and Air models) Height, stowed Width 718 / 628 lbs 326 / 285 kg 78 in 198 cm 29 in 73.6 cm Length Platform dimensions - all models Standard platform (l x w x h) gated or sliding mid-rail 27 x 26 x 443/4 in 69 x 66 x 114 cm Gated narrow platform (l x w x h) 26 x 20 x 443/4 in 66 x 51 x 114 cm Gated ultra-narrow platform (l x w x h) 22 x 18 x 443/4 in 56 x 46 x 114 cm Standard fiber platform (l x w x h) 29 x 261/2 x 431/2 in 74 x 67 x 110 cm Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 2-1 Section 2 • Specifications First Edition • Second Printing SPECIFICATIONS Model Standard Base Height, working maximum AWP-30S AWP-36S AWP-40S 35 ft 6 in 10.8 m 29 ft 6 in 9.0 m 350 lbs 159 kg 300 lbs 136 kg 42 ft 5 in 12.9 m 36 ft 6 in 11.1 m 350 lbs 159 kg 300 lbs 136 kg 46 ft 3 in 14.1 m 40 ft 3 in 12.3 m 300 lbs 136 kg 300 lbs 136 kg 12V 110V or 220V 100 psi / 6.9 bar -20°F to 135°F -29°C to 57°C 12V 110V or 220V 100 psi / 6.9 bar -20°F to 135°F -29°C to 57°C 1107 / 1017 lbs 502 / 461 kg 1091/2 in 278 cm 29 in 73.6 cm 1130 / 1040 lbs 513 / 472 kg 1091/2 in 278 cm 29 in 73.6 cm 46 in 55 in 117 cm 140 cm Outrigger footprint 691/4 x 611/4 in 831/4 x 751/4 in (l x w) Domestic 175.6 x 155.3 cm 211.6 x 191.2 cm Outrigger footprint 971/2 x 891/2 in 1171/4 x 1091/4 in (l x w) CSA 247.5 x 227.2 cm 297.8 x 278 cm Outrigger footprint 751/2 x 671/2 in 831/4 x 751/4 in (l x w) CE Indoor 192 x 171.4 cm 211.6 x 191.2 cm Outrigger footprint 1171/4 x 1091/2 in 1171/4 x 1091/2 in (l x w) CE Outdoor 297.8 x 278 cm 297.8 x 278 cm Corner access/wall access* 181/2 / 43/4 in 281/2 / 141/4 in Domestic 46.6 / 11.9 cm 72.7 / 36.2 cm Corner access/wall access* 37 / 183/4 in 52 / 311/4 in CSA 94.1 / 47.8 cm 132.5 / 79.3 cm Corner access/wall access* 221/4 / 8 in 281/2 / 141/4 in CE Indoor 56.5 / 20.3 cm 72.7 / 36.2 cm 3 3 Corner access/wall access* 50 /4 / 28 /4 in 52 / 311/4 in CE Outdoor 128.8 / 73 cm 132.5 / 79.3 cm * Corner of platform top rail to corner of wall with ability to rotate leveling jack. 55 in 140 cm 89 x 81 in 225.9 x 205.6 cm 1171/4 x 1091/4 in 297.8 x 278 cm 89 x 81 in 225.9 x 205.6 cm 1171/4 x 1091/2 in 297.8 x 278 cm 311/4 / 141/2 in 79.4 / 37.1 cm 503/4 / 283/4 in 128.8 / 73 cm 311/4 / 141/2 in 79.4 / 37.1 cm 503/4 / 283/4 in 128.8 / 73 cm Height, platform maximum Lift capacity all models except Canada Lift capacity models sold in Canada only Power source DC model 12V AC model 110V or 220V Air motor 100 psi / 6.9 bar Ambient Operating -20°F to 135°F Temperature -29°C to 57°C Machine weight (DC / AC and Air models) Height, stowed 831 / 741 lbs 377 / 336 kg 78 in 198 cm 29 in 73.6 cm Width Length Platform dimensions - all models Narrow fiber platform (l x w x h) 26 x 22 x 431/2 in 66 x 56 x 110 cm Front and side entry platform (l x w x h) 30 x 28 x 443/4 in 76 x 71 x 114 cm 2-2 Extra large platform (l x w x h) Genie AWP Super Series and Genie IWP Super Series 30 x 28 x 443/4 in 76 x 71 x 114 cm Part No. 38139 First Edition • Second Printing Section 2 • Specifications SPECIFICATIONS Model AWP-15S AWP-20S AWP-25S AWP-30S 711 / 621 lbs 322 / 282 kg 745 / 655 lbs 338 / 297 kg 780 / 690 lbs 353 / 313 kg 814 / 724 lbs 369 / 328 kg Height, stowed 78 in 198 cm 78 in 198 cm 78 in 198 cm 78 in 198 cm Width 22 in 55.8 cm 22 in 55.8 cm 22 in 55.8 cm 22 in 55.8 cm Length 491/2 in 125.7 cm 491/2 in 125.7 cm 491/2 in 125.7 cm 491/2 in 125.7 cm Outrigger footprint (l x w) Domestic 64 x 481/4 in 162.5 x 122.5 cm 64 x 481/4 in 162.5 x 122.5 cm 64 x 481/4 in 162.5 x 122.5 cm 711/2 x 58 in 181.6 x 147.3 cm Outrigger footprint (l x w) CSA 711/2 x 58 in 181.6 x 147.3 cm 741/2 x 651/2 in 189.2 x 166.3 cm 831/4 x 74 in 211.4 x 187.9 cm 951/4 x 893/4 in 241.9 x 227.9 cm Outrigger footprint (l x w) CE Indoor 64 x 481/4 in 162.5 x 122.5 cm 711/4 x 58 in 181.6 x 147.3 cm 711/4 x 58 in 181.6 x 147.3 cm 741/2 x 651/2 in 189.2 x 166.3 cm Outrigger footprint (l x w) CE Outdoor 831/4 x 74 in 211.4 x 187.9 cm 831/4 x 74 in 211.4 x 187.9 cm 951/4 x 893/4 in 241.9 x 227.9 cm 112 x 112 in 284.4 x 284.4 cm Corner access/wall access* 16 / 11 in Domestic 40.6 / 27.9 cm 141/4 / 81/2 in 36.2 / 21.6 cm 13 / 6 in 33 / 15.2 cm 181/2 / 71/4 in 47 / 18.4 cm Corner access/wall access* 221/2 / 143/4 in CSA 57.1 / 37.5 cm 241/2 / 14 in 62.2 / 35.5 cm 283/4 / 15 in 73 / 38.1 cm 371/2 / 181/2 in 95.2 / 47 cm Corner access/wall access* 16 / 11 in CE Indoor 40.6 / 27.9 cm 21 / 121/4 in 53.3 / 31.1 cm 191/2 / 93/4 in 49.5 / 24.7cm 22 / 9 in 55.8 / 22.8 cm 311/2 / 20 in 80 / 50.8 cm 30 / 171/2 in 76.2 / 44.4 cm 383/4 / 21 in 98.4 / 53.3 cm 51 / 261/2 in 129.5 / 67.3 cm Narrow Base Machine weight (DC / AC and Air models) Corner access/wall access* CE Outdoor * Corner of platform top rail to corner of wall with ability to rotate leveling jack. Platform dimensions Gated ultra-narrow platform (l x w x h) 22 x 18 x 443/4 in 56 x 46 x 117 cm Gated narrow platform (l x w x h) 26 x 20 x 443/4 in 66 x 51 x 114 cm Narrow fiber platform (l x w x h) 26 x 22 x 431/2 in 66 x 56 x 110 cm Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 2-3 Section 2 • Specifications First Edition • Second Printing SPECIFICATIONS Model AWP-15S AWP-20S AWP-25S AWP-30S Machine weight 715 / 625 lbs (DC / AC and Air models) 324.5 / 283.7 kg 750 / 660 lbs 339.7 / 298.9 kg 784 / 694 lbs 355.3 / 314.6 kg 819 / 729 lbs 371 / 330.2 kg Rough Terrain Base Height, stowed 79 in 201 cm 79 in 201 cm 79 in 201 cm 79 in 201 cm Width 291/2 in 75 cm 291/2 in 75 cm 291/2 in 75 cm 291/2 in 75 cm Length 58 in 147 cm 58 in 147 cm 58 in 147 cm 58 in 147 cm Outrigger footprint (l x w) Domestic 64 x 481/4 in 162.5 x 122.5 cm 64 x 481/4 in 162.5 x 122.5 cm 64 x 481/4 in 162.5 x 122.5 cm 711/2 x 58 in 181.6 x 147.3 cm Outrigger footprint (l x w) CSA 711/2 x 58 in 181.6 x 147.3 cm 741/2 x 651/2 in 189.2 x 166.3 cm 831/4 x 74 in 211.4 x 187.9 cm 951/4 x 893/4 in 241.9 x 227.9 cm Outrigger footprint (l x w) CE Indoor 64 x 481/4 in 162.5 x 122.5 cm 711/4 x 58 in 181.6 x 147.3 cm 711/4 x 58 in 181.6 x 147.3 cm 741/2 x 651/2 in 189.2 x 166.3 cm Outrigger footprint (l x w) CE Outdoor 831/4 x 74 in 211.4 x 187.9 cm 831/4 x 74 in 211.4 x 187.9 cm 951/4 x 893/4 in 241.9 x 227.9 cm 112 x 112 in 284.4 x 284.4 cm Corner access/wall access* 16 / 11 in Domestic 40.6 / 27.9 cm 141/4 / 81/2 in 36.2 / 21.6 cm 13 / 6 in 33 / 15.2 cm 181/2 / 71/4 in 47 / 18.4 cm Corner access/wall access* 221/2 / 143/4 in CSA 57.1 / 37.5 cm 241/2 / 14 in 62.2 / 35.5 cm 283/4 / 15 in 73 / 38.1 cm 371/2 / 181/2 in 95.2 / 47 cm Corner access/wall access* 16 / 11 in CE Indoor 40.6 / 27.9 cm 21 / 121/4 in 53.3 / 31.1 cm 191/2 / 93/4 in 49.5 / 24.7cm 22 / 9 in 55.8 / 22.8 cm 311/2 / 20 in 80 / 50.8 cm 30 / 171/2 in 76.2 / 44.4 cm 383/4 / 21 in 98.4 / 53.3 cm 51 / 261/2 in 129.5 / 67.3 cm Corner access/wall access* CE Outdoor * Corner of platform top rail to corner of wall with ability to rotate leveling jack. Platform dimensions Standard platform (l x w x h) gated or sliding mid-rail 27 x 26 x 443/4 in 69 x 66 x 114 cm Narrow fiber platform (l x w x h) 26 x 22 x 431/2 in 66 x 56 x 110 cm Gated ultra-narrow platform (l x w x h) 22 x 18 x 443/4 in 56 x 46 x 117 cm Front and side entry platform (l x w x h) 30 x 28 x 443/4 in 76 x 71 x 110 cm Gated narrow platform (l x w x h) 26 x 20 x 443/4 in 66 x 51 x 114 cm Extra large platform (l x w x h) 30 x 28 x 443/4 in 76 x 71 x 110 cm Standard fiber platform (l x w x h) 29 x 261/2 x 431/2 in 74 x 67 x 110 cm 2-4 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 2 • Specifications SPECIFICATIONS Model IWP-20S IWP-25S IWP-30S Height, working maximum 26 ft 5 in 8.1 m 30 ft 5 in 9.3 m 35 ft 6 in 10.8 m Height, platform maximum 20 ft 5 in 6.2 m 24 ft 5 in 7.4 m 29 ft 6 in 9.0 m Lift capacity 350 lbs 159 kg 350 lbs 159 kg 350 lbs 159 kg Lift capacity with outreach option 300 lbs 136 kg — — — — 12V 110V or 220V 12V 110V or 220V 12V 110V or 220V 1245 / 1345 lbs 565 / 610 kg 1290 / 1390 lbs 585 / 630 kg 1290 / 1390 lbs 585 / 630 kg 76 in / 78 in 198 / 203 cm 76 in / 78 in 198 / 203 cm 76 in / 78 in 198 / 203 cm Width - Standard base 32 in 81 cm 32 in 81 cm — — Length - Standard base 60 in 152 cm 60 in 152 cm — — Width - Wide base — — — — 40 in 102 cm Length - Wide base — — — — 60 in 69 cm Platform length 27 in 69 cm 27 in 69 cm 27 in 69 cm Platform width 26 in 66 cm 26 in 66 cm 26 in 66 cm Platform height 443/4 in 114 cm 443/4 in 114 cm 443/4 in 114 cm Corner access 6 in 15 cm 6 in 15 cm 7 in 18 cm Power source DC model AC model Machine weight (AC / DC models) Height, stowed base fully lowered/base raised Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 2-5 Section 2 • Specifications First Edition • Second Printing SPECIFICATIONS Platform function speed, maximum AWP-15S Platform function speed, maximum AC DC 40 seconds 28 seconds 30 seconds 28 seconds AC DC 40 seconds 28 seconds 30 seconds 28 seconds AC DC 40 seconds 28 seconds 30 seconds 28 seconds AC DC 40 seconds 28 seconds 30 seconds 28 seconds AC DC 40 seconds 42 seconds 52 seconds 42 seconds AC DC 65 seconds 38 seconds 48 seconds 38 seconds Hydraulic pressure, maximum All Models 1600 psi 110 bar Platform up Platform down AWP-20S Platform up Platform down AWP-25S Platform up Platform down AWP-30S Platform up Platform down AWP-36S Platform up Platform down AWP-40S Platform up Platform down 2-6 IWP - all models AC DC 40 seconds 28 seconds 30 seconds 28 seconds Hydraulic pressure, maximum All Models 1600 psi 110 bar Platform up Platform down Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 2 • Specifications SPECIFICATIONS Hydraulic Hose and Fitting Torque Specifications Your machine is equipped with either 37° flared fittings and hose ends OR Parker Seal-Lok® fittings and hose ends. Genie specifications require that fittings and hose ends be torqued to specification when they are removed and installed or when new hoses or fittings are installed. SAE O-ring Boss Port SAE O-ring Boss Port (tube fitting - installed into Aluminum) (tube fitting - installed into Steel) SAE Dash size Torque SAE Dash size Torque -4 11 ft-lbs / 14.9 Nm -4 16 ft-lbs / 21.7 Nm -6 23 ft-lbs / 31.2 Nm -6 35 ft-lbs / 47.5 Nm -8 40 ft-lbs / 54.2 Nm -8 60 ft-lbs / 81.3 Nm -10 69 ft-lbs / 93.6 Nm -10 105 ft-lbs / 142.4 Nm -12 93 ft-lbs / 126.1 Nm -12 140 ft-lbs / 190 Nm -16 139 ft-lbs / 188.5 Nm -16 210 ft-lbs / 284.7 Nm -20 172 ft-lbs / 233.2 Nm -20 260 ft-lbs / 352.5 Nm -24 208 ft-lbs / 282 Nm -24 315 ft-lbs / 427.1 Nm Seal-Lok Fittings JIC 37° Fittings (hose end) (swivel nut or hose connection) ® SAE Dash size Torque -4 18 ft-lbs / 24.4 Nm -6 Thread Size Flats -4 7/16-20 2 27 ft-lbs / 36.6 Nm -6 9/16-18 1 1/4 -8 40 ft-lbs / 54.2 Nm -8 3/4-16 1 -10 63 ft-lbs / 85.4 Nm -10 7/8-14 1 -12 90 ft-lbs / 122 Nm -12 1 1/16-12 1 -16 120 ft-lbs / 162.7 Nm -16 1 5/16-12 1 -20 140 ft-lbs / 190 Nm -20 1 5/8-12 1 -24 165 ft-lbs / 223.7 Nm -24 1 7/8-12 1 Part No. 38139 SAE Dash size Genie AWP Super Series and Genie IWP Super Series 2-7 Section 2 • Specifications First Edition • Second Printing SPECIFICATIONS 3 Working clockwise on the body hex fitting, make a second mark with a permanent ink marker to indicate the proper tightening position. Torque Procedure JIC 37° fittings 1 Align the tube flare (hex nut) against the nose of the fitting body (body hex fitting) and tighten the hex nut to the body hex fitting to hand-tight, approximately 30 in-lbs / 3.4 Nm. Use the JIC 37° Fittings table on the previous page to determine the correct number of flats for the proper tightening position. 2 Make a reference mark on one of the flats of the hex nut, and continue it on to the body hex fitting with a permanent ink marker. The marks indicate that the correct tightening positions have been determined. Use the second mark on the body hex fitting to properly tighten the joint after it has been loosened. a b c d b a c b a b c d hydraulic hose hex nut reference mark body hex fitting a b c body hex fitting reference mark second mark 4 Tighten the hex nut until the mark on the hex nut is aligned with the second mark on the body hex fitting. 5 Operate all machine functions and inspect the hoses and fittings and related components to confirm that there are no leaks. 2-8 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 2 • Specifications SPECIFICATIONS Seal-Lok® fittings 1 Replace the O-ring. The O-ring must be replaced anytime the seal has been broken. The O-ring cannot be re-used if the fitting or hose end has been tightened beyond finger tight. The O-rings used in the Parker Seal Lok® fittings and hose ends are custom-size O-rings. They are not standard SAE size O-rings. They are available in the O-ring field service kit (Genie part number 49612). 2 Lubricate the O-ring before installation. 3 Be sure that the face seal O-ring is seated and retained properly. 4 Position the tube and nut squarely on the face seal end of the fitting and tighten the nut finger tight. 5 Tighten the nut or fitting to the appropriate torque per given size as shown in the table. 6 Operate all machine functions and inspect the hoses and fittings and related components to confirm that there are no leaks. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 2-9 Section 2 • Specifications First Edition • Second Printing SPECIFICATIONS This page intentionally left blank. 2 - 10 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 3 • Theory of Operation Theory of Operation Power Source Limit Switches The Genie AWP Super Series and Genie IWP Super Series have multiple power options: AC models: 110V AC or 220V AC DC models: 12V DC Air motor: 100 psi / 6.9 bar @ 80 cfm / 37760 cc/sec There is one limit switch for all IWP CE models with Platform Outreach (Option). This limit switch is located on the carriage mount. When the platform outreach is extended, the limit switch is activated and cuts power to the up/down functions. Hydraulic System All machine functions are performed by the hydraulic system, which contains either a hydraulic pump and an electric power unit or a hydraulic pump and an air motor power unit. Platform elevate and the Power Wheel Assist (Option) functions are powered by a single-section gear pump, rated at 0.5 to 0.6 gpm at 2000 psi / 1.89 to 2.27 L/min at 138 bar for AC and Air models, 0.7 to 1 gpm at 2000 psi / 2.6 to 3.76 L/ min at 138 bar for DC models. The pump supplies hydraulic fluid under pressure to the hydraulic manifold, where the directional and flow control valves are located, and to the drive manifold (if equipped). To protect from over-pressurization of the system, the hydraulic pump is provided with a pressure relief valve, set at 2700 psi / 186 bar. The power wheel assist function is managed by a bi-directional hydraulic motor connected to a single drive/steer wheel. By first raising the chassis using the foot pump, the drive/steer wheel will lower, then by activating the directional rocker switch on the steer handle, you can move the machine in the direction desired while steering with the steer handle. Electrical System All functions are accomplished by first pressing a control activate button and then pushing a button on the control panel, which sends voltage or air to the appropriate directional control valve. These directional valves determine which direction the hydraulic fluid will travel. Part No. 38139 Machine Controls The Genie AWP Super Series and Genie IWP Super Series machines are equipped with operational controls which are found in two locations: the ground controls, located in two positions, on the side of the mast (standard base models), and in the front of the mast opposite the platform (narrow and rough terrain models), and the platform controls, located in the platform. Ground controls: Only auxiliary platform lowering is available by pressing the auxiliary platform lowering button. For models with Power Wheel Assist Option, pull and hold the function enable lever to either side of the switch, and press the thumb rocker switch and drive the machine in the desired direction of travel. When releasing the thumb rocker switch, the machine will continue to roll. To set the brake, you must release the function enable lever. To move a machine without power wheel assist, pull and hold the function enable lever to release the brake. Release the function enable lever to stop the machine and set the brake. The brake will hold the machine on inclines of less than 3°. Platform controls are activated by pressing the control activate button, then rotating the mast up/down function switch in the direction indicated on the control panel decal. Washing electronic components is not suggested. Instead, use compressed air to remove debris. Genie AWP Super Series and Genie IWP Super Series 3-1 Section 3 • Theory of Operation First Edition • Second Printing This page intentionally left blank. 3-2 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 4 • Scheduled Maintenance Procedures Scheduled Maintenance Procedures About This Section This section contains detailed procedures for each scheduled maintenance inspection. Each procedure includes a description, safety warnings and step-by-step instructions. Observe and Obey: Maintenance inspections shall be completed by a person trained and qualified on the maintenance of these machines. Scheduled maintenance inspections shall be completed daily, quarterly and annually as specified on the Maintenance Inspection Report. Failure to properly complete each inspection when required may result in death, serious injury or substantial machine damage. Immediately tag and remove from service a damaged or malfunctioning machine. Repair any machine damage or malfunction before operating machine. Use only Genie approved replacement parts. Machines that have been out of service for a period longer than 3 months must complete the quarterly inspection. Unless otherwise specified, perform each procedure with the machine in the following configuration: Symbols Legend Safety alert symbol–used to alert personnel to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may cause minor or moderate injury. Indicates a potentially hazardous situation which, if not avoided, may result in property damage. Indicates that a specific result is expected after performing a series of steps. Indicates that an incorrect result has occurred after performing a series of steps. · Machine parked on a firm, level surface · Platform in the stowed position · Key switch in the off position with the key removed · The red Emergency Stop button in the off position at both ground and platform controls · Wheels chocked Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 4-1 Section 4 • Scheduled Maintenance Procedures First Edition • Second Printing SCHEDULED MAINTENANCE PROCEDURES Maintenance Symbols Legend Pre-delivery Preparation Report Note: The following symbols have been used in this manual to help communicate the intent of the instructions. When one or more of the symbols appears at the beginning of a maintenance procedure, it conveys the meaning below. The pre-delivery preparation report contains checklists for each type of scheduled inspection. Make copies of the Pre-delivery Preparation report to use for each inspection. Store completed forms as required. Maintenance Schedule Indicates that tools will be required to perform this procedure. Indicates that new parts will be required to perform this procedure. Indicates that dealer service is required to perform this procedure. There are three types of maintenance inspections that must be performed according to a schedule— daily, quarterly, and annual. The Scheduled Maintenance Procedures Section and the Maintenance Inspection Report have been divided into three subsections—A, B, and C. Use the following chart to determine which group(s) of procedures are required to perform a scheduled inspection. Inspection Table or Checklist Daily or every 8 hours Quarterly or every 250 hours Annual Inspection or every 1000 hours A A+B A+B+C Maintenance Inspection Report The maintenance inspection report contains checklists for each type of scheduled inspection. Make copies of the Maintenance Inspection Report to use for each inspection. Maintain completed forms for a minimum of 4 years or in compliance with your employer, jobsite and governmental regulations and requirements. 4-2 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 Pre-Deliver Pre-Deliveryy Preparation First Edition • Second Printing Section 4 • Scheduled Maintenance Procedures Fundamentals Instructions It is the responsibility of the dealer to perform the Pre-delivery Preparation. Use the operator’s manual on your machine. The Pre-delivery Preparation is performed prior to each delivery. The inspection is designed to discover if anything is apparently wrong with a machine before it is put into service. A damaged or modified machine must never be used. If damage or any variation from factory delivered condition is discovered, the machine must be tagged and removed from service. Repairs to the machine may only be made by a qualified service technician, according to the manufacturer's specifications. Scheduled maintenance inspections shall be performed by qualified service technicians, according to the manufacturer's specifications and the requirements listed in the responsibilities manual. The Pre-delivery Preparation consists of completing the Pre-operation Inspection, the Maintenance items and the Function Tests. Use this form to record the results. Place a check in the appropriate box after each part is completed. Follow the instructions in the operator’s manual. If any inspection receives an N, remove the machine from service, repair and re-inspect it. After repair, place a check in the R box. Legend Y = yes, completed N = no, unable to complete R = repaired Comments Pre-Delivery Preparation Y N Pre-operation inspection completed Maintenance items completed Function tests completed Model Serial number Date Machine owner Inspected by (print) Inspector signature Inspector title Inspector company Genie Industries USA 18340 NE 76th Street PO Box 97030 Redmond, WA 98073-9730 (425) 881-1800 Genie UK The Maltings, Wharf Road Grantham, Lincolnshire NG31- 6BH England (44) 1476-584333 Part No. 38139 Genie AWP Super Series Copyright © 2002 by Genie Industries. Genie® is a registered trademark of Genie and Genie IWP Super Series Industries. Rev A 4-3 R Section 4 • Scheduled Maintenance Procedures First Edition • Second Printing This page intentionally left blank. 4-4 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 4 • Scheduled Maintenance Procedures Maintenance Inspection Report Model Checklist A Serial number A-1 Manuals and decals B-1 Battery A-2 Pre-operation inspection B-2 Electrical wiring A-3 Function tests B-3 Welds A-4 Damage, loose or missing parts B-4 Tilt-back operation if equipped A-5 Hydraulic leaks B-5 A-6 Check Hydraulic oil Level Lifting chain adjustments B-6 Test base operationIWPS models Clean and lubricate columns B-7 Lifting capacity B-8 Sequencing cables B-9 Proper outrigger length AWPS models Date Y N R Checklist B Y N R Machine owner Inspected by (print) Inspector signature Inspector title A-7 Inspector company A-8 Instructions · Make copies of this report to use for each inspection. Auxiliary lowering operation A-9 · Select the appropriate checklist(s) for the type of inspection to be performed. Manual lowering operation A-10 Columns A-11 Sequencing cables Daily or 8 hour Inspection: A Quarterly or 250 hour Inspection: A+B Annual or 1000 hour Inspection: A+B+C · Place a check in the appropriate box after each inspection procedure is completed. · Use the step-by-step procedures in this section to learn how to perform these inspections. · If any inspection receives an “N”, remove the machine from service, repair and re-inspect it. After repair, place a check in the “R” box. Legend Y = yes, acceptable N = no, unacceptable A-12 Interlock system operation A-13 Power and function controls A-14 Lifting chains and idler wheels B-10 Inspect and lubricate the outrigger leveling jack footpads AWPS models B-11 Level sensing IWPS models B-12 Chain adjustment IWP-20S models with outreach A-15 Breather cap A-16 Tire pressure Checklist C A-17 Air line lubricator oil level - Air models C-1 Casters and wheels C-2 Mast assembly A-18 Oil drip rate Air models C-3 Lifting chains C-4 Hydraulic oil C-5 Auxiliary platform lowering batteries C-6 Lifting chains A-19 Air filter/regulator Air models Y N R R = repaired Comments Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 4-5 Section 4 • Scheduled Maintenance Procedures First Edition • Second Printing Checklist A Procedures A-1 Inspect the Manuals and Decals Maintaining the operator’s and safety manuals in good condition is essential to safe machine operation. Manuals are included with each machine and should be stored in the container provided in the platform. An illegible or missing manual will not provide safety and operational information necessary for a safe operating condition. In addition, maintaining all of the safety and instructional decals in good condition is mandatory for safe machine operation. Decals alert operators and personnel to the many possible hazards associated with using this machine. They also provide users with operation and maintenance information. An illegible decal will fail to alert personnel of a procedure or hazard and could result in unsafe operating conditions. 3 Open the operator's manual to the decals inspection section. Carefully and thoroughly inspect all decals on the machine for legibility and damage. Result: The machine is equipped with all required decals, and all decals are legible and in good condition. Result: The machine is not equipped with all required decals, or one or more decals are illegible or in poor condition. Remove the machine from service until the decals are replaced. 4 Always return the manuals to the storage container after use. Note: Contact your authorized Genie distributor or Genie Industries if replacement manuals or decals are needed. 1 Check to make sure that the operator's and safety manuals are present and complete in the storage container on the platform. 2 Examine the pages of each manual to be sure that they are legible and in good condition. Result: The operator's manual is appropriate for the machine and all manuals are legible and in good condition. Result: The operator's manual is not appropriate for the machine or all manuals are not in good condition or is illegible. Remove the machine from service until the manual is replaced. 4-6 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 4 • Scheduled Maintenance Procedures CHECKLIST A PROCEDURES A-2 Perform Pre-operation Inspection A-3 Perform Function Tests Completing a Pre-operation Inspection is essential to safe machine operation. The Pre-operation Inspection is a visual inspection performed by the operator prior to each work shift. The inspection is designed to discover if anything is apparently wrong with a machine before the operator performs the function tests. The Pre-operation Inspection also serves to determine if routine maintenance procedures are required. Completing the function tests is essential to safe machine operation. Function tests are designed to discover any malfunctions before the machine is put into service. A malfunctioning machine must never be used. If malfunctions are discovered, the machine must be tagged and removed from service. Complete information to perform this procedure is available in the appropriate operator's manual. Refer to the Operator's Manual on your machine. Part No. 38139 Complete information to perform this procedure is available in the appropriate operator's manual. Refer to the Operator's Manual on your machine. Genie AWP Super Series and Genie IWP Super Series 4-7 Section 4 • Scheduled Maintenance Procedures CHECKLIST A First Edition • Second Printing PROCEDURES A-4 Inspect for Damage and Loose or Missing Parts · IWPS models: Hydraulic manifolds and foot pump · IWPS models: Foot pads · AWPS models: Outriggers, leveling jacks and foot pads · Dents or damage to machine Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. · Corrosion or oxidation · Cracks in welds or structural components Daily machine condition inspections are essential to safe machine operation and good machine performance. Failure to locate and repair damage, and discover loose or missing parts may result in an unsafe operating condition. IWPS models with Power Wheel Assist Option: 1 Inspect the entire machine for damage and improperly installed or missing parts including: · Electrical components, wiring and electrical cables IWP-20S models with Outreach Option: · Steer handle · Hydraulic motor and hoses · Locking bracket · Handle and handle lock · Electrical cable anchors and pulleys · Outreach extension arms · Hydraulic power unit, hoses, fittings, cylinder(s) and manifolds · Chain and sprocket · Sequencing cables, anchors and pulleys · Lifting chains and idler wheels · Adjustable glide pads · Mast columns and counterweight(s) · Mast covers · Nuts, bolts and other fasteners · Platform entry mid-rail or gate · Breather cap 4-8 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 4 • Scheduled Maintenance Procedures CHECKLIST A PROCEDURES A-5 Check for Hydraulic Leaks A-6 Check the Hydraulic Oil Level Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Detecting hydraulic fluid leaks is essential to operational safety and good machine performance. Undiscovered leaks can develop into hazardous conditions, impair machine functions and damage machine components. Maintaining the hydraulic oil at the proper level is essential to machine operation. Improper hydraulic oil levels can damage hydraulic components. Daily checks allow the inspector to identify changes in oil level that might indicate the presence of hydraulic system problems. 1 Inspect for hydraulic oil puddles, dripping or residue on or around the following areas: 1 Be sure the platform is fully lowered. · Hydraulic power unit—tank, valves, fittings 2 Remove the fasteners from the hydraulic power unit cover. · Hydraulic cylinder(s) 3 Remove the cover. · Flow control valve 4 Check the sight gauge on the side of the hydraulic tank. · Ground area under the machine · Hydraulic hoses and fittings · IWPS models: Hydraulic manifolds and foot pump IWPS models with Power Wheel Assist Option: · Hydraulic motor and hoses Result: The hydraulic oil level should be visible in the middle of the sight gauge. 5 Add oil if needed. Do not overfill. 6 Replace the cover. Hydraulic System Hydraulic fluid Chevron Rando HD equivalent Hydraulic tank capacity all models Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 3 quarts 2.8 liters 4-9 Section 4 • Scheduled Maintenance Procedures CHECKLIST A First Edition • Second Printing PROCEDURES A-7 Test the Base Operation IWPS Models A-8 Check the Auxiliary Platform Lowering Operation Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Testing the base for proper operation is essential for safe machine operation. An unsafe working condition exists if the base fails to operate properly. The base should operate smoothly and be free of hesitation, jerking and binding. The auxiliary platform lowering is powered by a secondary battery pack that is located in the ground control box. The auxiliary platform lowering can be activated from the ground or platform controls. Detection of an auxiliary lowering malfunction is essential for safe machine operation. An unsafe working condition exists if the auxiliary platform lowering function does not operate in the event of a main power failure. 1 Pump the foot pedal 7 to 9 complete strokes. Result: The non-adjustable foot pads should raise 11/2 to 2 inches / 4 to 5 cm off the ground. 2 Pull the base lowering handle. Result: The base should lower, putting all four foot pads in firm contact with the ground. 3 Raise the platform slightly. Result: The inner frame wheels should lift off the ground. 1 Raise the platform slightly. 2 Disconnect the power source from the machine. 3 Push in the auxiliary platform lowering button at the ground controls. Result: Platform should lower. 4 Connect the power source to the machine. 5 Raise the platform slightly. 6 Disconnect the power source from the machine. 7 Push in the control activate button and rotate the up/down switch in the down direction. Result: Platform should lower. 4 - 10 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 4 • Scheduled Maintenance Procedures CHECKLIST A A-9 Check the Manual Platform Lowering Operation Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Detection of a manual lowering malfunction is essential for safe machine operation. An unsafe working condition exists if the manual lowering function does not operate in the event of a main and auxiliary power failure. 1 Raise the platform slightly. 2 Activate the manual lowering valve located at the bottom of the hydraulic cylinder. Result: The platform should lower. PROCEDURES A-10 Inspect the Columns for Damage Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Detection of damage to columns is essential for safe machine operation. An unsafe working condition exists if the columns are damaged and do not operate smoothly, free of hesitation and binding. A daily check of the columns allows the inspector to identify changes in the operating condition of the column assembly that might indicate damage. 1 Visually inspect each column for the following: · Dents, gouges or abrasions · Bends or warping · Excessive wear 2 Raise and lower the platform through a complete cycle. Result: The platform should raise and lower smoothly, free of hesitation and binding. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 4 - 11 Section 4 • Scheduled Maintenance Procedures CHECKLIST A First Edition • Second Printing PROCEDURES A-11 Check the Sequencing Cables Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Detection of damage to sequencing cables or components is essential for safe machine operation. An unsafe working condition exists if the sequencing components are damaged and do not operate smoothly. A daily check of the sequencing system allows the inspector to identify changes in the operating condition that might indicate damage. 1 Visually inspect the cables and components for the following: · Frayed or broken wire strands · Kinks in the cable · Corrosion · Paint or foreign materials · Broken or damaged pulleys · Unusual or excessive pulley wear · Split or cracked threaded swage ends 2 Confirm the following: · Cables are on the pulleys · Upper and lower cable ends are properly secured · Upper and lower mounting brackets are properly secured A-12 Check the Interlock System for Proper Operation Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Testing the interlock system for malfunctions is essential for safe machine operation. An unsafe working condition exists if any interlock display light fails to operate properly. AWPS models 1 Turn the key switch to ground control and pull out the red Emergency Stop button to the ON position. Twist to release the red Emergency Stop button at the platform controls. Result: AC & DC models: The power light should be on. Air models: The air pressure gauge should read 80 - 110 psi / 5.5 - 7.8 bar 2 Slide each outrigger into a base socket until the outrigger lock pin snaps into place. Adjust outriggers to level using the outrigger screw jack until the base casters are slightly off the ground. 3 Check the interlock display lights at the ground controls. Result: Confirm that the corresponding light is on. 4 Repeat steps 2 and 3 for each of the remaining outriggers. IWPS models 4 - 12 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 4 • Scheduled Maintenance Procedures CHECKLIST A 1 Turn the key switch to ground control and pull out the red Emergency Stop button to the ON position. Twist to release the red Emergency Stop button at the platform controls. Result: The power light should be on. 2 Pull the base lowering handle to fully lower the base. 3 Use the bubble level and adjust the leveling jacks until the machine is level and all four foot pads are in firm contact with the ground. Result: Within 1 to 3 seconds, all four interlock display lights should turn on and remain on. 4 Pump the foot pedal to raise the base. Result: Both foot pad interlock display lights should be off. 5 Pull the base lowering handle to lower the base. Result: The base will lower and both foot pad interlock display lights should be on. 6 Pump the foot pedal to raise the base. 7 Turn both leveling jacks clockwise to the full/ extended position. 8 Pull the base lowering handle to lower the base. Result: The base will lower and the two level sensor interlock display lights should be off and remain off. 9 Push in the red Emergency Stop button at the platform controls. 10 Push in the control activate button and rotate the up/down switch in the UP position, then the DOWN position. Result: Platform up/down functions should not operate. PROCEDURES A-13 Test the Power and Function Controls Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Testing the machine functions and the Emergency Stop buttons for malfunctions is essential for safe machine operation. An unsafe working condition exists if any function fails to operate properly or either red Emergency Stop button fails to stop all the machine functions. Each function should operate smoothly and be free of hesitation, jerking and unusual noise. 1 Turn the key switch to ground control and pull out the red Emergency Stop button to the ON position. Twist to release the red Emergency Stop button at the platform controls. Result: The power light should be on. 2 Push in the control activate button and rotate the up/down switch in the UP position, then the DOWN position. Result: Platform up/down functions should operate. 3 Push in the red Emergency Stop button at the platform controls to the OFF position. 4 Push in the control activate button and rotate the up/down switch in the UP position, then the DOWN position. Result: The up/down functions should not operate. 5 Push in the red Emergency Stop button at both platform and ground controls. 6 Push in the control activate button and rotate the up/down switch in the UP position, then the DOWN position. Result: The up/down functions should not operate. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 4 - 13 Section 4 • Scheduled Maintenance Procedures CHECKLIST A First Edition • Second Printing PROCEDURES A-14 Inspect the Lifting Chains and Idler Wheels 4 Inspect the chain terminations near the bottom of each column to confirm that the chain tensioner bracket is centered in the inspection hole. Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. a Maintaining the lifting chains and idler wheels in good condition is essential to safe machine operation. Failure to find and replace damaged chains or idler wheels could result in unsafe operating conditions and may cause component damage. b d c 1 Raise the platform approximately 3 feet / 1 m. 2 Visually inspect the chains and idler wheels near the top of each column for the following: · Excessive corrosion a b c d chain tensioner bracket adjustment nut (hidden from view) termination rod (hidden from view) column · Broken or missing chain leafs and pins · Tight or kinked joints in the chain · Missing or damaged idler wheels and related components 3 Inspect the chain terminations near the bottom of each column to confirm that each termination has a lock nut. 4 - 14 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 4 • Scheduled Maintenance Procedures CHECKLIST A A-15 Inspect the Breather Cap Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. The hydraulic tank is vented to the atmosphere. The breather cap has an internal air filter that can clog and may cause the power unit to operate improperly. If the breather cap is not properly installed and checked daily, impurities can enter the hydraulic system and may cause component damage. 1 Be sure the breather cap is installed on the hydraulic power unit tank and is not damaged. Do not remove it. PROCEDURES A-17 Check the Air Supply Lubricator Oil Level - Air Models Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Maintaining the proper oil level in the lubricator canister is essential to safe operation and good machine performance. Failure to keep the lubricator canister at the proper oil level could result in unsafe operating conditions and may cause component damage. 1 Be sure the platform is fully lowered. A-16 Check the Tire Pressure AWPS Models with Rough Terrain Base Option 2 Inspect the lubricator canister for proper oil level. Result: The oil level must be within 1/2 inch / 12.7 mm from the top of the lubricator canister. 3 To add oil, remove the oil lubricator canister from the lubricator base and fill with oil. Install the canister back onto the lubricator base. Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. a It is essential to maintain proper pressure in all airfilled tires. Improperly inflated tires can affect machine handling. b 1 Check the tire pressure with an air pressure gauge. Add air as needed. a b Models before serial number 3899-11837. Tire pressure should be 30 psi / 2 bar in the front and rear tires. Models after serial number 3899-11836. oil lubricator base oil lubricator canister Oil Specification Oil Type 10W automotive engine oil Tire pressure should be 50 psi / 3.4 bar in the front and rear tires. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 4 - 15 Section 4 • Scheduled Maintenance Procedures CHECKLIST A First Edition • Second Printing PROCEDURES A-18 Check the Air Supply Lubricator Drip Rate - Air Models A-19 Check the Air Filter/Regulator Canister - Air Models Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Genie specifications require that this procedure be performed every 8 hours or daily, whichever comes first. Maintaining the proper oil drip rate into the air supply is essential to safe operation and good machine performance. Failure to maintain the proper drip rate could result in machine component damage. It is essential to drain the air filter/regulator canister of water to ensure good air motor performance and service life. A water-filled canister could cause the air motor to perform poorly and continued use may cause component damage. 1 While raising the platform, visually inspect the oil lubricator sight gauge. 1 Check the air filter/regulator canister for any water accumulation. 2 If water is visible, loosen the drain plug at the bottom of the canister and allow the water to drain out. Result: There should be a maximum of 1 to 2 drops of oil visible in the sight gauge. 2 To adjust the drip rate, turn the oil flow control valve clockwise to decrease the flow or counterclockwise to increase the flow. 3 Tighten the drain plug. 3 Repeat this procedure until the proper oil drip rate is achieved. a a b b c a b c a b 4 - 16 air filter/regulator air filter/regulator canister air filter/regulator canister drain plug oil lubricator flow control valve oil lubricator sight gauge Genie AWP Super Series and Genie IWP Super Series Part No. 38139 July 2010 Section 4 • Scheduled Maintenance Procedures Checklist B Procedures REV B 4 Check the battery acid level. If needed, replenish with distilled water to the bottom of the battery fill tube. Do not overfill. B-1 Inspect the Battery 5 Install the battery vent caps. Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. 6 If equipped: Set the battery charger AC Selector switch to the proper voltage. 7 Set the power switch to the AUTO position. Result: The charger ammeter should be ON. Proper battery condition is essential to good machine performance and operational safety. Improper fluid levels or damaged cables and connections can result in component damage and hazardous conditions. Electrocution/burn hazard. Contact with hot or live circuits could result in death or serious injury. Remove all rings, watches and other jewelry. Bodily injury hazard. Batteries contain acid. Avoid spilling or contacting battery acid. Neutralize battery acid spills with baking soda and water. 1 Put on protective clothing and eye wear. 2 Be sure that the battery cable connections are tight and free of corrosion. Note: Adding terminal protectors and a corrosion preventative sealant will help eliminate corrosion on the battery terminals and cables. 3 Remove the battery vent caps and check the specific gravity of each battery cell with a hydrometer. Result: If any battery cell displays a specific gravity of less than 1.026, the battery must be replaced. Part No. 38139 AWP Super Series • IWP Super Series 4 - 17 Section 4 • Scheduled Maintenance Procedures CHECKLIST B July 2010 PROCEDURES B-2 Inspect the Electrical Wiring REV B B-3 Inspect All Welds Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. Maintaining electrical wiring in good condition is essential to safe operation and good machine performance. Failure to find and replace burnt, chafed, corroded or pinched wires could result in unsafe operating conditions and may cause component damage. Weld inspections are essential to safe machine operation and good machine performance. Failure to locate and repair damage may result in an unsafe operating condition. 1 Visually inspect the welds in the following locations: · Platform · Base Electrocution/burn hazard. Contact with hot or live circuits could result in death or serious injury. Remove all rings, watches and other jewelry. 1 Inspect the following areas for burnt, chafed, corroded and loose wires: · All base wiring · Mast brace mounting bracket AWPS models: · Loading pivot bar · Outrigger storage sockets · Tilt-back frame (if equipped) · Inside ground control box · Tilt-back frame mounting bracket (if equipped) · Hydraulic power unit IWPS models: · All external electrical cables · Foot pads · Inside platform control box · Power wheel assist (if equipped) · DC models: battery pack · AC power supply cord · IWPS models: inside base junction box · IWPS models: power wheel assist manifold (if equipped) 4 - 18 AWP Super Series • IWP Super Series Part No. 38139 July 2010 Section 4 • Scheduled Maintenance Procedures REV B CHECKLIST B B-4 Test the Tilt-back Operation (if equipped) Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. A tilt-back frame is standard equipment on AWP-36S and 40S and optional on AWP-15S, 20S, 25S and 30S. The tilt-back frame allows the machine to be rolled through a standard doorway. Failure to detect improper tilt-back operation could result in unsafe operating conditions and may cause injury and component damage. 1 Fully lower the platform. 2 Remove the outriggers from the base and place in the storage sockets. PROCEDURES 6 Slide out the T-handle until the lock pin snaps into the locked position. Crushing hazard. The machine could fall if the T-handle lock pin is not locked into the base. 7 Lift the machine with the T-handle to the mid-tilt position (casters on tilt-back frame contact the floor, and machine supported by the extended tiltback strut). Use the appropriate number of people and proper lifting techniques. 8 Continue lifting until telescoping tilt-back strut is completely compressed. 9 Return the machine to the standing position. Carefully pull down T-handle until machine rests at mid-tilt position. 3 Maintain a firm grasp on the tilt-back frame and remove the retaining pin. 4 Lower the tilt-back frame and guide the tilt-back strut into the strut socket. 10 Lower the machine with the T-handle until base casters are in contact with the ground. Use the appropriate number of people and proper lifting techniques. 11 Return the sliding T-handle to stowed position. 12 Stow the tilt-back frame in the upright position and insert the retaining pin. 5 Insert the retaining pin into the strut socket. Crushing hazard. The machine will fall if the retaining pin is not locked into the strut socket. Part No. 38139 AWP Super Series • IWP Super Series 4 - 19 Section 4 • Scheduled Maintenance Procedures CHECKLIST B July 2010 PROCEDURES B-5 Check the Lifting Chain Adjustments REV B 2 AWPS models: Measure the distance between the top of the base frame and the bottom edge of the platform. Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. Maintaining proper adjustment of the lifting chains is essential to safe machine operation. Failure to maintain proper chain adjustment could result in unsafe operating conditions and may cause component damage. 1 Fully lower the platform and measure the maximum height of the machine. IWPS models: Turn the screw jacks counterclockwise to the full up position. Pull the base lowering handle to lower the base. IWPS models: Measure the distance between the bottom edge of the platform to the top of the counterweight. Result: The machine should be no taller than specification. Note: If measurement does not meet specification, adjust the chains. See Repair procedure 5-4, How to Adjust the Lifting Chains. Result: The measurement should be no less than specification. Note: If measurement does not meet specification, adjust the chains. See Repair procedure 5-4, How to Adjust the Lifting Chains. 4 - 20 AWP Super Series • IWP Super Series Part No. 38139 July 2010 Section 4 • Scheduled Maintenance Procedures REV B CHECKLIST B Specifications Model Height Measurement (step 2) IWP-20S 76 in 193 cm 3 in 7.6 cm IWP-25S 76 in 193 cm 3 in 7.6 cm IWP-30S 76 in 193 cm 3 in 7.6 cm AWP-15S 78 in 198 cm 3 in 7.6 cm AWP-20S 78 in 198 cm 3 in 7.6 cm AWP-25S 78 in 198 cm 3 in 7.6 cm AWP-30S 78 in 198 cm 3 in 7.6 cm AWP-36S 1091/2 in 278 cm 3 in 7.6 cm AWP-40S 1091/2 in 278 cm 3 in 7.6 cm PROCEDURES B-6 Clean and Lubricate the Columns Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. Clean and properly lubricated columns are essential to good machine performance and safe operation. Extremely dirty conditions may require that the columns be cleaned and lubricated more often. 1 Raise the platform to the maximum height. 2 Visually inspect the inner and outer channels of the columns for debris or foreign material. If necessary, use a mild cleaning solvent to clean the columns. Bodily injury hazard. This procedure will require the use of additional access equipment. Do not place ladders or scaffold on or against any part of the machine. Performing this procedure without the proper skills and tools could result in death or serious injury. Dealer service is strongly recommended. 3 If needed, apply a generous amount of Boe-lube wax (Genie part number 90337) to the inside and outside channels of each column. Part No. 38139 AWP Super Series • IWP Super Series 4 - 21 Section 4 • Scheduled Maintenance Procedures CHECKLIST B July 2010 PROCEDURES REV B B-7 Test the Lifting Capacity B-8 Adjust the Sequencing Cables Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. Proper lifting capacity is essential to safe machine operation. Improper lifting capacity adjustment could allow machine to be overloaded and may cause death or serious injury. Maintaining proper adjustment of the sequencing cables is essential for safe machine operation. An unsafe working condition exists if the sequencing cables are improperly adjusted. A daily check of the sequencing cables allows the inspector to identify changes in the operating condition that might indicate damage. Bodily injury hazard. This procedure requires specific repair skills, lifting equipment and a suitable workshop. Attempting this procedure without these skills and tools could result in death or serious injury and significant component damage. Dealer service is strongly recommended. 1 Place the maximum rated load in the platform. Secure the load to the platform. Before serial number 3899-11844 1 Fully lower the platform. 2 Check the deflection on each sequencing cable by grasping the cable halfway down the column and pulling the cable to one side then the other. Measure the total distance between the two points (this is the maximum deflection). Note: Refer to the operator's manual or the load capacity decal on the machine to determine the maximum load capacity. a b 2 Raise the platform slightly. c Result: The hydraulic power unit should raise the platform. 3 Fully lower the platform. 4 Add an additional 30 pounds / 14 kg to the platform. Secure the additional weight. 5 Raise the platform slightly. Result: The hydraulic power unit should not be able to raise the platform. a b c adjustment (tension) nut threaded swage end sequencing cable Note: If the hydraulic power unit is unable to lift rated load or lifts more than rated load, see Repair procedure 3-6, Valve Adjustment. 4 - 22 AWP Super Series • IWP Super Series Part No. 38139 July 2010 Section 4 • Scheduled Maintenance Procedures REV B CHECKLIST B 3 If needed, adjust the sequencing cable deflection. 4 Hold the threaded swage end of the cable from turning and adjust the tension nut to obtain correct deflection. Turn the adjustment nut clockwise to decrease the deflection or counterclockwise to increase the deflection. PROCEDURES After serial number 3899-11843 1 Fully lower the platform. 2 Check for proper deflection of each sequencing cable by inspecting the spring compression. The spring is located between the nylock nut and the upper sequencing bracket. Component damage hazard. Do not exceed the recommended deflection. 5 Raise and lower the platform through three complete cycles and confirm deflection. 6 Repeat adjustment for each cable as required. Specification Deflection, Maximum 11/2 to 21/2 inches 3.8 to 6.4 cm a b c d nylock nut spring upper sequencing bracket sequencing cable 3 Compress the spring to 15/16 in / 2.4 cm by turning the nylock nut clockwise to increase the spring compression or counterclockwise to decrease the spring compression. Component damage hazard. Do not exceed the recommended spring compression. 4 Confirm the spring measurement on each sequencing cable. 5 Raise and lower the platform through three complete cycles and confirm the spring compression. 6 Repeat the adjustment for each cable as required. Part No. 38139 AWP Super Series • IWP Super Series 4 - 23 Section 4 • Scheduled Maintenance Procedures CHECKLIST B July 2010 PROCEDURES B-9 Inspect for Proper Outrigger Length - AWPS Models REV B ANSI Models AWP-15S 20 inches 50.8 cm (including narrow and rough terrain base options) AWP-20S 20 inches 50.8 cm (including narrow and rough terrain base options) Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. Proper outrigger length is essential to safe machine operation. Operating a machine with outriggers different from those originally designed for the model will result in death or serious injury. 1 Measure each outrigger and verify for proper length. AWP-25S 20 inches 50.8 cm (including narrow and rough terrain base options) AWP-30S 26 inches 66 cm (including narrow and rough terrain base options) AWP-36S 36 inches 91.4 cm AWP-40S 40 inches 101.6 cm CSA Models AWP-15S 20 inches 50.8 cm (including narrow and rough terrain base options) AWP-20S 26 inches 66 cm (including narrow and rough terrain base options) AWP-25S 36 inches 91.4 cm (including narrow and rough terrain base options) Length 4 - 24 AWP-30S 46 inches 117 cm (including narrow and rough terrain base options) AWP-36S 60 inches 152 cm AWP-40S 60 inches 152 cm AWP Super Series • IWP Super Series Part No. 38139 July 2010 Section 4 • Scheduled Maintenance Procedures REV B CHECKLIST B CE Indoor Models AWP-15S 20 inches 50.8 cm (including narrow and rough terrain base options) AWP-20S 20 inches 50.8 cm AWP-20S 26 inches (narrow and rough terrain base options) 66 cm AWP-25S 26 inches 66 cm (including narrow and rough terrain base options) AWP-30S 30.5 inches 77 cm AWP-30S 36 inches (narrow and rough terrain base options) 91.4 cm AWP-36S 36 inches 91.4 cm AWP-40S 40 inches 102 cm CE Outdoor Models PROCEDURES B-10 Inspect and Lubricate the Outrigger Leveling Jack Footpads - AWPS Models Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. Detection of unusual wear of the leveling jack footpads is essential for safe machine operation. An improperly lubricated and or damaged footpad could result in an unsafe condition. AWP-15S 46 inches 117 cm (including narrow and rough terrain base options) 1 Visually inspect the leveling jack footpads for any unusual wear. AWP-20S 2 Liberally apply grease to the top of the footpads at the swivel point and the leveling jack threads. 46 inches 117 cm AWP-20S 60 inches (narrow and rough terrain base options) 152 cm a outrigger leveling jack threads AWP-25S 60 inches 152 cm (including narrow and rough terrain base options) AWP-30S 60 inches 152 cm AWP-30S 75 inches (narrow and rough terrain base options) 191 cm AWP-36S 75 inches 191 cm AWP-40S 85 inches 216 cm a c b b c Grease Type Part No. 38139 AWP Super Series • IWP Super Series outrigger footpad outrigger footpad swivel point Lithium-based 4 - 25 Section 4 • Scheduled Maintenance Procedures CHECKLIST B July 2010 PROCEDURES B-11 Test the Level Sensing Operation - IWPS Models REV B 8 Pull the base lowering handle to lower the base. Result: Within 1 to 4 seconds, two interlock display lights should turn off and remain off. 9 Repeat steps 4 through 8 to test the opposite side of the machine. 10 Pump the foot pedal to raise the base. Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. Detection of level sensing malfunctions is essential for safe machine operation. An improperly functioning level sensing system could result in unsafe operating conditions. 1 Position the machine on a firm, level surface 2 Turn the key switch to ground control and pull out the red Emergency Stop button to the ON position. Twist to release the red Emergency Stop button at the platform controls. Result: The power light should be on. 3 Adjust the leveling jacks until the bubble is in the center ring of the bubble level and all four foot pads are in firm contact with the ground. Result: Within 1 to 4 seconds, all four interlock display lights should turn on and remain on. 4 Pump the foot pedal to raise the base. 5 Place a 1/4 inch / 6.35 mm thick spacer under one adjustable and one non-adjustable foot pad on the same side of the machine. 6 Pull the base lowering handle to lower the base. Result: Within 1 to 4 seconds, all four interlock display lights should turn on and remain on. 11 Place a 3/4 inch / 19 mm thick spacer under both adjustable foot pads. 12 Pull the base lowering handle to lower the base. Result: Within 1 to 4 seconds, all four interlock display lights should turn on and remain on. 13 Pump the foot pedal to raise the base. 14 Turn the leveling jacks counterclockwise enough to fit a 11/2 inch / 3.8 cm spacer under each adjustable foot pad. 15 Turn the leveling jacks clockwise until the foot pads just touch the spacers. 16 Pull the base lowering handle to lower the base. Result: Within 1 to 4 seconds, two interlock display lights should turn off and remain off. 17 Pump the foot pedal to the raise the base. 18 To test the non-adjustable foot pads, turn the leveling jacks counterclockwise all the way. 19 Place a 11/2 inch / 3.8 cm spacer under each non-adjustable foot pad. 20 Pull the base lowering handle to lower the base. Result: Within 1 to 4 seconds, two interlock display lights should turn off and remain off. 7 Repeat steps 4 and 5 using a 1/2 inch / 12.7 mm spacer. 4 - 26 AWP Super Series • IWP Super Series Part No. 38139 July 2010 Section 4 • Scheduled Maintenance Procedures REV B CHECKLIST B PROCEDURES B-12 Check the Chain Adjustment, IWP-20S Models with Outreach Option Genie specifications require that this procedure be performed every 250 hours or quarterly, whichever comes first. Detection of a improperly adjusted platform outreach chain is essential for safe machine operation. Failure to detect an improperly adjusted platform outreach chain could result in unsafe operating conditions and may cause injury and component damage. 1 Fully lower the platform. 2 Lower the base and turn the key switch off. 3 Fully extend the outreach and lock the handle. 4 Locate the chain between the lower sprocket and the lower brace. 5 Grasp the two chain sections and lightly pinch them together. Result: There should be a minimum of a 1/4 inch / 6.4 mm gap between the chain sections. Note: If measurement does not meet specification, adjust the chains. See Repair procedure 7-3, How to Adjust the Platform Outreach Chain. Part No. 38139 AWP Super Series • IWP Super Series 4 - 27 Section 4 • Scheduled Maintenance Procedures July 2010 Checklist C Procedures REV B C-1 Inspect and Lubricate the Casters and Wheels C-2 Inspect the Mast Assembly for Wear Genie specifications require that this procedure be performed every 1000 hours or annually, whichever comes first. Genie specifications require that this procedure be performed every 1000 hours or annually, whichever comes first. Extremely dirty conditions may require that the casters and wheels be inspected and lubricated more often. Detection of excessive or unusual wear in the mast assembly is essential for safe machine operation. An unsafe working condition exists if the mast assembly has excessive wear or does not operate smoothly, free of hesitation and binding. 1 Visually inspect each caster and wheel for cuts, cracks or unusual wear. 2 Push the machine on a flat smooth surface and check that the casters and wheels roll smoothly. 3 Pump grease into the zerk fitting on each caster and wheel until it can be seen coming out of the bearing seal gap. Grease Type Lithium-based 1 Remove the mast covers. 2 Raise the platform until 3 to 5 inches / 7.6 to 12.7 cm of each column is visible. 3 Visually inspect the top of each column for clearance between the roller wheels and the adjacent column surface. Result: There should be a equal amount of distance between the roller wheel and the column on each side. Note: If mast inspection results in a measurement that is not within specification, refer to Repair procedure 5-3, How to Adjust the Glide Pads. 4 Loosen but do not remove the adjustment nut on the sequencing cable located at the top of the first column. 4 - 28 AWP Super Series • IWP Super Series Part No. 38139 July 2010 Section 4 • Scheduled Maintenance Procedures REV B CHECKLIST C PROCEDURES 8 Inspect each idler wheel for the following: · Excessive wear on the side flanges · Unusual wear · Movement side to side in excess of 0.079 inch / 2 mm · Any movement of wheel front to back a 5 Raise the platform approximately 3 feet / 1 m above the top of the base. b c 6 Place a jack stand on the top of the base, centered under the platform. Adjust the jack stand to 24 inches / 61 cm. a a b c b idler wheel spacer lifting chain Note: If idler wheel inspection results in a measurement that is not within specification, replace the idler spacers. Refer to Repair procedure 5-2, How to Assemble the Mast. c a b c 9 Raise the platform and remove the jack stand and the support blocks. Then lower the platform. platform jack stand base 7 Lower the platform onto the jack stand just enough to take the weight off the lifting chains. 10 Install the mast covers and adjust the sequencing cable. See B-8, Adjust the Sequencing Cables. Crushing hazard. Keep away from lowering platform. Part No. 38139 AWP Super Series • IWP Super Series 4 - 29 Section 4 • Scheduled Maintenance Procedures CHECKLIST C July 2010 PROCEDURES C-3 Inspect and Lubricate the Lifting Chains Genie specifications require that this procedure be performed every 1000 hours or annually, whichever comes first. Lubricated chains are essential to good machine performance and safe operation. Extremely dirty conditions may require that the chains be cleaned and lubricated more often. 1 Raise the platform to the maximum height. REV B C-4 Replace the Hydraulic Oil Genie specifications require that this procedure be performed every 1000 hours or annually, whichever comes first. Replacement of the hydraulic oil is essential for good machine performance and service life. Dirty oil and a dirty suction strainer may cause the machine to perform poorly and continued use may cause component damage. Extremely dirty conditions may require oil changes to be performed more often. 2 Inspect each lifting chain. Refer to Repair procedure 5-4, How to Inspect the Lifting Chains. 1 Fully lower the platform. 3 Lubricate each chain with a dry-type spray lubricant. 3 Remove the drain plug from the tank and allow all of the oil from the tank to drain into a suitable container. See capacity specifications. Bodily injury hazard. This procedure will require the use of additional access equipment. Do not place ladders or scaffold on or against any part of the machine. Performing this procedure without the proper skills and tools could result in death or serious injury. Dealer service is strongly recommended. 2 Remove the plastic cover from the power unit. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. 4 IWPS models with Power Wheel Assist Option: Tag and disconnect the hose at the bottom of the tank and drain oil into a suitable container. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. 4 - 30 AWP Super Series • IWP Super Series Part No. 38139 July 2010 Section 4 • Scheduled Maintenance Procedures REV B CHECKLIST 5 Remove the tank from the hydraulic power unit. 6 Remove the suction strainer from the pick-up tube and the magnet from inside the tank and clean them using a mild solvent. 7 Install the suction strainer. 8 Install the drain plug using thread sealer on the threads. 9 Install the hydraulic tank. 10 Fill the tank with hydraulic oil until the level is visible in the sight gauge on the side of the tank. Do not overfill. 11 Replace the breather cap (Genie part number 38159) with a new one. 12 Raise and lower the platform through three complete cycles. Add hydraulic oil if needed to allow platform to reach full height. Clean up any oil that may have spilled. Properly discard the used oil. C PROCEDURES Hydraulic System Hydraulic fluid Chevron Rando HD equivalent Hydraulic tank capacity all models 3 quarts 2.8 liters Hydraulic system capacity (includes tank) AC and DC models IWP-20S IWP-25S IWP-30S 3.7 quarts 3.7 quarts 3.7 quarts 3.5 liters 3.5 liters 3.5 liters AC, DC and Air powered models AWP-15S AWP-20S AWP-25S AWP-30S AWP-36S AWP-40S 3.7 quarts 3.7 quarts 3.7 quarts 3.7 quarts 4.0 quarts 3.9 quarts 3.5 liters 3.5 liters 3.5 liters 3.5 liters 3.8 liters 3.7 liters Component damage hazard. Do not allow the hydraulic tank to completely empty when raising the platform. Pressurized air in the hydraulic system can damage hydraulic components. Part No. 38139 AWP Super Series • IWP Super Series 4 - 31 Section 4 • Scheduled Maintenance Procedures CHECKLIST C July 2010 PROCEDURES REV B C-5 Replacing the Auxiliary Platform Lowering Batteries C-6 Remove and Inspect the Lifting Chains Genie specifications require that this procedure be performed every 1000 hours or annually, whichever comes first. Genie specifications require that this procedure be performed every 5 years. 1 Turn the key switch off and remove the key. 2 Remove the ground control box cover fasteners. 3 Open the ground control box and locate the auxiliary battery pack inside. 4 Remove the fasteners that hold the battery pack in place. 5 Carefully slide the battery pack out of the holder. Note: The wires connected to the battery pack are very small. Be careful not to damage the wires. The lifting chains are responsible for the raising and lowering of the platform. Performing a careful and thorough inspection of the chains on a regular basis is essential to good machine performance and safe machine operation. The lifting chains should operate smoothly and be free of hesitation, jerking and unusual noise. 1 Remove the lifting chains from the mast. Refer to Repair procedure 5-2, How to Disassemble the Mast. 2 Inspect each lifting chain. Refer to Repair procedure 5-4, How to Inspect the Lifting Chains. 6 Remove the old batteries from the pack. 7 Insert new batteries into the pack. Note: Make sure the batteries are installed correctly by following the diagram on the inside of the battery pack. 8 Install the battery pack into the ground control box and tighten the fasteners. 9 Close the ground control box cover and tighten the fasteners. Do not overtighten. 4 - 32 AWP Super Series • IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts Troubleshooting Flow Charts Before Troubleshooting: Read, understand and obey the safety rules and operating instructions printed in the Genie AWP Super Series Operator's Manual OR the Genie IWP Super Series Operator's Manual. Observe and Obey: Be sure that all necessary tools and test equipment are available and ready for use. Troubleshooting and repair procedures shall be completed by a person trained and qualified on the repair of this machine. Read each appropriate flow chart thoroughly. Attempting shortcuts may produce hazardous conditions. Immediately tag and remove from service a damaged or malfunctioning machine. Be aware of the following hazards and follow generally accepted safe workshop practices. Repair any machine damage or malfunction before operating the machine. Electrocution hazard. Contact with electrically charged circuits may result in death or serious injury. Remove all rings, watches and other jewelry. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. Perform all troubleshooting on a firm level surface. Two persons will be required to safely perform some troubleshooting procedures. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5-1 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing TROUBLESHOOTING FLOW CHARTS About This Section When a malfunction is discovered, the flow charts in this section will help a service professional pinpoint the cause of the problem. To use this section, basic hand tools and certain pieces of test equipment are required—voltmeter, ohmmeter, pressure gauges. The location of terminals mentioned in this section can be found on the appropriate electrical or hydraulic schematics provided in Section 7, Schematics. General Repair Process Malfunction discovered Identify symptoms Troubleshoot problem still exists Return to service problem solved Inspect and test Perform repair Since various degrees of a particular function loss may occur, selecting the appropriate flow chart may be troublesome. When a function will not operate with the same speed or power as a machine in good working condition, refer to the flow chart which most closely describes the problem. 5-2 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts Chart 1 Power Light Will Not Turn On AC Models Be sure the key switch is in the appropriate position. Be sure both red Emergency Stop buttons are pulled out to the ON position. Be sure the ground control box printed circuit board fuse is not blown. Be sure the AC power supply cord is plugged into a live outlet. Be sure the ground control box circuit breaker has not been tripped. With the key switch turned to ground control and both Emergency Stop buttons pulled out to the ON position, check the voltage on the BK 110V AC wire at the input side of the key switch KS1. 0V AC Repair or replace the AC power supply plug D5 and/or the 12/3 power cable. 110V AC Check the voltage on the BK 110V AC wire at the input side of the key switch KS1. 0V AC Replace KS1. 110V AC Check the voltage on the BK 110V AC wire at the input side of the Emergency Stop button P1. 0V AC Repair open in BK wire from P1 to KS1. 110V AC Check the voltage on the YL wire at the output side of P1. 0V AC Replace P1. 110V AC Check voltage on the BK wire at the transformer U9. 0V AC Repair open in the YL wire at the thermal device U12 between P1 and U9 OR replace U9. 110V AC Continued on the next page. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5-3 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing CHART 1 Continued from the previous page. Check voltage at terminals 1 and 3 on terminal strip W4. Place positive lead of volt meter on terminal 1 then 3 and the negative lead on terminal 10. 0V AC Repair U9 wires OR replace U9. 12V or more Replace the ground control PC Board U10. 5-4 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts Chart 2 Power Light Will Not Turn On DC Models Be sure the key switch is in the appropriate position. Be sure both red Emergency Stop buttons are pulled out to the ON position. Be sure the ground control box PC board fuse is not blown. Be sure the battery cables are connected. Disconnect the battery pack(s) QD1 and check voltage at battery side connector. 12V DC Connect battery pack(s) QD1 and check voltage on the BK wire at the input side of the key switch KS1. less than 12V DC Check battery condition and replace bad battery OR check for short circuits OR check battery cables OR consult Genie Industries Service Department. 0V DC Repair open in BK wire from QD1 to QD7 to KS1. 12V DC Check voltage at the output side of KS1. 0V DC Replace KS1. 12V DC Check voltage on the BK wire at the input side of the Emergency Stop button P1. 0V DC Repair open in BK wire from P1 to KS1. 12V DC Check voltage at the output side of the Emergency Stop button P1. 0V DC Replace KS1. 12V DC Check voltage at terminal 3 on terminal strip W3. 0V DC Repair open in BK wire from P1 to W3. 12V DC Replace the ground control PC Board U10. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5-5 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing Chart 3 Interlock Lights Will Not Turn On AWPS AC and DC Models Be sure the key switch is in the appropriate position. Be sure both red Emergency Stop buttons are pulled out to the ON position. Be sure the outriggers are the correct length. Be sure the leveling jacks are in firm contact with the ground. Be sure the ground control box PC board fuse is not blown. 5-6 With the key switch turned to ground control and both Emergency Stop buttons pulled out to the ON position, check voltage at terminal 8 on terminal strip W4. Place the positive lead of the volt meter on terminal 8 and the negative lead on terminal 10 of the terminal strip W4. 0V DC Replace the PC board U10. bad Repair or replace the connectors in QD4. 12V DC Disconnect the power supply. Unplug the base cable quick disconnect QD4 from the ground control box EN2. Inspect the male and female connectors for damage. good no Connect QD4 and perform a continuity test continuity from terminal 8 of the terminal strip W4 to terminals 4, 5, 6 and 7 on terminal strip W4. continuity Inspect the outrigger contacts and the base contacts SW13,14,15 and 16 for damage. bad Repair or replace contacts. good Repair open in wires. Replace the PC board U10 OR consult Genie Industries Service Department. Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts Chart 4 Foot Pad Interlock Lights Will Not Turn On IWPS Models Be sure the key switch is in the appropriate position. Be sure both red Emergency Stop buttons are pulled out to the ON position. Be sure the power light is on. Be sure the unit is set up according to the operator's manual. Be sure the ground control box PC board fuse is not blown. With the key switch turned to ground control and both red Emergency Stop buttons pulled out to the ON position, check for voltage at terminal 8 on terminal strip W4. Place the positive lead of the volt meter on terminal 8 and the negative lead on terminal 10 of terminal strip W4. 0V DC Replace the PC board U10. bad Repair or replace the connectors in QD4. 0V DC Replace 16/6 cable because of open in black wire. 0V DC Repair or replace open in black wire from W6 to SW17 and S18. 0V DC Remove the foot pad switch and perform a continuity test. 12V DC Disconnect the power supply. Unplug the base cable quick disconnect QD4 from the ground control box EN2. Inspect the male and female connectors for damage. good Connect QD4 and check voltage at the #7 BK wire from QD4 to terminal strip W6. 12V DC Remove the foot pad switch access covers on the base weldment, check for voltage at the N.C. terminals at SW17 and SW18. 12V DC With the key switch turned to ground control and both Emergency Stop buttons pulled out to the ON position, activate each footpad switch and check for voltage on the N.O. side of SW17 and SW18. 12V DC no continuity Replace the footpad switch. continuity Repair open in BK wires from W6 to the N.C. terminals on SW17 and SW18. Consult Genie Industries Service Department. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5-7 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing Chart 5 Level Sensor Interlock Lights Will Not Turn On IWPS Models Be sure the key switch is in the appropriate position. Be sure both red Emergency Stop buttons are pulled out to the ON position. Be sure the power light is on. Be sure the unit is set up according to the operator's manual. Be sure the ground control box PC board fuse is not blown. With the key switch turned to ground control and both Emergency Stop buttons pulled out to the ON position, check voltage at terminal 8 on terminal strip W4. Place the positive lead of volt meter on terminal 8 and the Negative lead on terminal 10 of terminal strip W4. 0V DC Replace the PC board U10. bad Repair or replace the connectors in QD4. 0V DC Replace 16/6 cable because of open in BK wire. 12V DC Disconnect the power supply. Unplug the base cable quick disconnect QD4 from the ground control box and inspect the male and female connectors for damage. good Connect QD4 and check for voltage at the #7 BK wire from QD4 to terminal strip W6. 12V DC Separate the wire connections at the level sensor S7 and check for voltage at the BK wire on the wire harness side. Place negative lead of volt meter at the GN wire, on the wire harness side. 0V DC Relocate negative lead of volt meter to terminal 10 of the terminal strip W4 on U10. 12V DC Repair open in ground wire from W4 to QD4 OR QD4 to W6 OR W6 to S7 and/or tighten connections at terminal strips. 12V DC Continued on the next page. 5-8 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts CHART 5 Continued from the previous page. Connect S7 and check for voltage at the #1 white wires at W6. 0V DC Repair or replace S7. 12V DC Check voltage at terminals 4 and 5 of terminal strip W4. Place negative lead of volt meter at terminal 10 of terminal strip W4. 0V DC Replace 16/6 cable because of open in wires from terminals 4 and 5 at W4 OR repair open at QD4 OR tighten the wire nut on the #1 white wires at W6. 12V DC Replace PC board U10 OR consult Genie Industries Service Department. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5-9 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing Chart 6 Platform Up Function Inoperative AC Models Be sure the key switch is in the appropriate position. Be sure both red Emergency Stop buttons are pulled out to the ON position. Be sure the ground control box circuit breaker has not been tripped. Be sure the ground control box PC board fuse is not blown. Be sure all interlock display lights are on. With the key switch turned to ground control and both Emergency Stop buttons pulled out to the ON position, check voltage at terminal 9 on terminal strip W4 on PC board U10. Place negative lead of volt meter on terminal 10 on terminal strip W4. 0V DC Replace PC board U10. 12V DC Check voltage at the N.O. contacts at the Emergency Stop button P2 in platform control box EN1. Place negative lead of volt meter on terminal 10 of terminal strip W4. 0V DC Replace 16/6 cable because of open in RD wire OR repair open in base cable quick disconnect QD3. 12V DC Check voltage at the N.C. contact on P2. 0V DC Replace Emergency Stop button P2 N.C. contact. 0V DC Replace wire between Emergency Stop button P2 and control activate switch SW8. 0V DC Replace control activate switch SW8 N.O. contact . 12V DC Check voltage at the input side of control activate switch SW8. 12V DC Press and hold control activate switch SW8. Check voltage at the output side of the N.O. contact at SW8. 12V DC Continued on the next page. 5 - 10 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts CHART 6 Continued from the previous page. With the key switch turned to ground control and both Emergency Stop buttons pulled out to the ON position, press in the control activate switch SW8, check voltage at terminal 4 of SW11 contact. 0V DC Replace the wire between control activate switch contact SW8 and up/down switch contact SW11. 12V DC Press and hold the control activate switch SW8 and activate SW11 in the UP direction, hold both switches and check voltage at terminal 3 on SW11 contact. 0V DC Replace up/down switch SW11 N.O. contact. 12V DC Press and hold the control activate switch SW8 and activate SW11 in the up direction, hold both switches and check voltage at terminal 13 on terminal strip W4 at PC board U10. 0V DC Replace 16/6 cable because of open in OR wire from SW11 to W4 OR repair open in QD3. 12V DC Press and hold the control activate switch SW8 and activate SW11 in the up direction, hold both switches and check voltage at terminal 11 on terminal strip at W4 PC board U10. 0V DC Replace PC board U10 OR consult Genie Industries Service Department. 12V DC Press and hold the control activate switch SW8 and activate SW11 in the up direction, hold both switches and check voltage at RD wire from W4 to M5 motor contactor. 0V DC Repair open in RD wire from W4 to M5 motor contactor. 12V DC Continued on the next page. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5 - 11 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing CHART 6 Continued from the previous page. Press and hold the control activate switch SW8 and activate SW11 in the up direction, hold both switches and check voltage at terminal 11 of terminal strip W4 while placing the negative lead of the volt meter on terminal 10 at terminal strip W4. 0V DC Repair open circuit from terminal 10 of terminal strip W4 to M5 motor contactor coil. 12V DC Perform a resistence test across the motor contactor coil at M5. 0 ohms Replace the motor contactor at M5. 1 to 5 ohms Check for 110 volts AC at the WH and BK wires of the motor contactor at M5. 0V AC Replace faulty circuit breaker CB1. 0V AC Replace the motor contactor at M5. 110V AC Press and hold the control activate switch SW8 and activate SW11 in the UP direction, hold both switches and check voltage at the N.O. terminals WH and BK wires on the motor contactor at M5. 110V AC Check the M5 motor wiring OR consult Genie Industries Service Department. 5 - 12 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts Chart 7 Platform UP Function Inoperative, But Power Unit Runs AC Models Be sure the power unit hydraulic tank is full and the breather cap has been installed. Be sure the key switch is in the appropriate position. Be sure both red Emergency Stop buttons are pulled out to the ON position. Be sure the ground control box PC board fuse is not blown. With the key switch turned to platform control and both Emergency Stop buttons pulled out to the ON position, press and hold the control activate switch SW8 and activate the up function at SW11 switch. Check voltage at the N.O. valve coil Y30 on the power unit M5. Wait 1 second before checking voltage. Connect the positive lead from a volt meter to the BK wire and the negative lead to the GN/ YL wire. 12V DC Check the resistance of the N.O. valve coil Y30. 0V DC While pushing in the control activate switch SW8 and activating the up function SW11, hold both switches and check voltage at terminal 12 on terminal strip W4. 0V DC Replace PC board U10. 12V DC Replace or repair open circuit from terminal 12 of the terminal strip W4. 0 or infinite ohms Replace Y30. 7 ohms Using a tee fitting, install a 0 to 3000 psi / 250 bar 1800 to pressure gauge in the 2000 psi pressure port (stamped P) of power unit M5. Push in the control activate switch SW8, activate the UP function SW11. Check for mechanical restrictions keeping the platform from moving OR consult Genie Industries Service Department. less than 1800 psi Continued on the next page. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5 - 13 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing CHART 7 Continued from the previous page. Remove the return to tank hose and plug the hose. Push in the control avtivate switch SW8, activate the up function. 1800 to 2000 psi Remove valve Y7 and inspect valve for contamination or damage OR consult Genie Industries Service Department. less than 1800 psi Remove and inspect valve Y30 for contamination or damage. Repair or replace valve and repeat pressure test. less than 1800 psi Adjust the pressure relief valve. See Repair procedure 1-2 OR repair or replace lift cylinder. less than 1800 psi Consult Genie Industries Service Department. 5 - 14 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts Chart 8 Pump Motor Will Not Operate DC Models Be sure the key switch is in the appropriate position. Be sure both red Emergency Stop buttons are pulled out to the ON position. Be sure the ground control box PC board fuse is not blown. Be sure all interlock display lights are on. Be sure the battery(s) is fully charged and properly connected. With the key switch turned to platform control and both Emergency Stop buttons pulled out to the ON position, press in the control activate switch SW8 and activate the up function SW11. Check for voltage on terminal 9 of terminal strip W4. 0V DC Replace the PC board U10. 12V DC Activate the up function and check for voltage on the RD wire at the input side of the Emergency Stop button P2 in platform control box EN1. 0V DC Replace 16/6 cable from P2 to W4 OR repair open in quick disconnect QD3. 12V DC Activate the up function and check voltage on the WH wire at the output side of P2. 0V DC Replace P2 contact. 12V DC Activate the up function and check voltage on the WH wire at the input side of the control activate switch SW8. 0V DC Repair open in wire circuit between P2 and SW8. 12V DC Activate the up function and check for voltage on the BK wire at the output side of SW8. 0V DC Replace SW8 contact. 12V DC Continued on the next page. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5 - 15 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing CHART 8 Continued from the previous page. Activate the up function and check for voltage on the BK wire at the input side of SW11. 0V DC Repair open in wire circuit between SW8 and SW11. 12V DC Activate the up function and check for voltage at the BK wire at the output side of SW11. 0V DC Replace SW11. 12V DC Activate the up function and check for voltage at terminal 13 on terminal strip W4. 0V DC Replace the 16/6 cable OR repair open in the quick disconnect QD3. 12V DC Activate the up function and check for voltage at terminal 11 on terminal strip W4. 0V DC Replace PC board U10 OR consult Genie Industries service Department. 12V DC Activate the up function and check for voltage at the RD wire on the motor contactor coil. 0V DC Repair open circuit in RD wire from terminal 11 on W4 to the motor contactor coil. 12V DC Check for continuity across the motor contactor coil. no continuity Replace the motor contactor. continuity Activate the up function and check for voltage at the N.O. side of the motor contactor (number 4 weld cable to M5 motor). 0V DC Replace the motor contactor. 12V DC Check the condition of the battery(s) B2 OR consult Genie Industries Service Department. 5 - 16 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts Chart 9 Platform Up Inoperative, Power Unit Runs DC Models Be sure all other functions operate normally. Be sure the power unit reservoir is full and the breather cap has been installed. Be sure the key switch is in the appropriate position. Be sure both red Emergency Stop buttons are pulled out to the on position. Be sure the ground control box PC board fuse is not blown. With the key switch turned to platform control and both Emergency Stop buttons pulled out to the on position, press in the control activate switch SW8 and activate the up function SW11. Check voltage on OR wire at the dump valve coil Y30 on the power unit M5. 12V DC Check the resistance of the dump valve coil Y30. 0V DC 0 or infinite ohms Replace or repair open in wire between the motor contactor coil at M5 and the Y30 valve coil. Replace Y30. 7 ohms Using a tee fitting install a 0 to 3000 psi / 206.8 bar pressure gauge in the pressure port (stamped P) of power unit M5. Activate the up function SW11, check the pressure. 1800 to 2000 psi Check for mechanical restrictions keeping the platform from moving OR consult Genie Industries Service Department. less than 1800 psi Remove the return to 1800 to tank hose and plug the 2000 psi hose fitting. leave the pressure gauge teed in at the P port fitting. Push in the control activate switch SW8, activate the up function. Remove Y7 and inspect valve for contamination or damage OR consult Genie Industries Service Department. less than 1800 psi Continued on the next page. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5 - 17 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing CHART 9 Continued from the previous page. Remove and inspect the dump valve Y30 for contamination or damage. Repair or replace valve and repeat pressure test again. less than 1800 psi Adjust the pressure relief valve. See Repair procedure 1-2 OR repair or replace the lift cylinder. less than 1800 psi Consult Genie Industries Service Department. 5 - 18 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts Chart 10 Platform Down Function Inoperative Be sure all other functions operate normally. With the key switch turned to platform control and both Emergency Stop buttons pulled out to the ON position, press in the control activate switch SW8 and activate the up function SW11. Check voltage on the WH/BK wire at the down valve coil Y7. 12V DC Be sure the ground control box PC board fuse is not blown. Replace valve coil. 7 ohms Pull the manual lowering knob (red knob) at the barrel end of the lift cylinder. platform does not lower Be sure the key switch is in the appropriate position. Be sure both red Emergency Stop buttons are pulled out to the ON position. Check the resistance of the Y7 down valve coil. 0 or infinite ohms platform lowers Repair or replace the platform down valve cartridge. Repair or replace the flow control valve (item D) OR Consult Genie Industries Service Department. 0V DC Perform a continuity test no from the GN/YL wire at continuity Y7 to terminal 10 on the pc board U10. Repair open in GN/YL circuit from Y7 to QD4 to terminal strip W5 to terminal 10 on pc board U10. continuity Activate the down function. Check voltage on the BL wire at the output side of SW11. 0V DC Replace the contacts on SW11. 12V DC Check voltage on the WH wire at the input side of the auxiliary down switch SW12. 0V DC Repair open in wire circuit from SW11 to QD3 to SW12. 12V DC Repair open in wire circuit from SW12 to QD4 to Y7 OR consult Genie Industries Service Department. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5 - 19 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing Chart 11 Base Will Not Raise With Foot Pump IWPS Models Be sure the platform is fully lowered. Be sure to pump the foot pedal with slow, even strokes. Be sure the power unit reservoir is full and the breather cap has been installed. Check the base release cable for proper adjustment. incorrect Adjust the base release cable. (see Repair Procedure 1-2). incorrect Adjust the base release valve. (see Repair Procedure 1-2). correct Check the manual release valve actuator (item I), for proper adjustment. correct Disconnect the hydraulic less than hose from the barrel end 1600 psi of the base lift cylinder. Install a 3000 psi / 250 bar pressure gauge in the hydraulic hose. Pump the foot pedal and check the pressure. Adjust the pressure relief valve. (see Repair Procedure 1-2) OR Consult Genie Industries Service Department. 1600 psi Replace the piston seal on the base lift cylinder OR consult Genie Industries Service Department. 5 - 20 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts Chart 12 Base Will Raise, But Will Not Hold In Up Position IWPS Models Check the base release cable for proper adjustment. incorrect Adjust the base release cable. (see Repair Procedure 1-2). incorrect Adjust the base relase valve. (see Repair Procedure 1-2). correct Check the manual release valve actuator (item I), for proper adjustment. correct Lower the base and inspect manual release valve (item I) OR check valve (item G). bad Repair or replace faulty item I or G. good Repair or replace base lift cylinder OR consult Genie Industries Service Department. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5 - 21 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing Chart 13 Base Will Not Lower IWPS Models Be sure there are no obstructions under the base. Check the base release cable for proper adjustment. incorrect Adjust the base release cable. (see Repair Procedure 1-2). correct incorrect Check the adjustment on the inner base frame. Adjust the inner base frame. (see Repair Procedure 1-2. correct Possible contamination of the hydraulic system in the foot pump manifold. Consult Genie Industries Service Department. 5 - 22 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts Chart 14 Platform Will Not Hold In Up Position With the key switch turned to platform control and both Emergency Stop buttons pulled out to the ON position, push in the control activate switch SW8 and the platform up function switch SW11 and raise the platform 5 feet / 1.5 m. Support the platform. Remove the return to tank hose from the hydraulic power unit M5. Remove the platform support and check for hydraulic oil flowing from the return to tank hose. no oil flow Repair or replace the hydraulic lift cylinder. oil flow Repair or replace check valve (item E) OR the normally closed down valve (item F). Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5 - 23 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing Chart 15 Power Unit Will Not Lift Rated Load Adjust the pressure relief valve (see Repair Procedure 1-2) OR consult Genie Industries Service Department. DC Models: Be sure the battery is fully charged and properly connected AC Models: Be sure machine is connected to a proper power supply. 5 - 24 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 5 • Troubleshooting Flow Charts Chart 16 Auxiliary Platform Lowering Will Not Operate Check the low auxiliary battery indicator light L6. on Replace the 8 AA size batteries B4. off Check voltage at terminal 9A of the terminal strip W4. 0V DC Replace the PC board U10 OR contact Genie Industries Service Department. 12V DC Check voltage on the RD wire at SW12. 0V DC Repair open wire circuit from terminal 9A on the PC board U10 to SW12. 12V DC Press and hold the auxiliary down switch SW12. Check voltage on the WH wire at SW12. 0V DC Replace SW12 contact. 12V DC Consult Genie Industries Service Department. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 5 - 25 Section 5 • Troubleshooting Flow Charts First Edition • Second Printing Chart 17 Power Wheel Assist Will Not Operate IWPS Models with Power Wheel Assist Consult Genie Industries Service Department. Be sure the base foot pads are not contacting the ground. Be sure the power unit tank is full and the breather cap has been installed. Be sure the key switch is in the appropriate position. Be sure both red Emergency Stop buttons are pulled out to the ON position. Be sure the ground control box PC board fuse is not blown. 5 - 26 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures Repair Procedures About This Section Most of the procedures in this section should only be performed by a trained service professional in a suitably equipped workshop. Select the appropriate repair procedure after troubleshooting the problem. Observe and Obey: Repair procedures shall be completed by a person trained and qualified on the repair of this machine. Immediately tag and remove from service a damaged or malfunctioning machine. Repair any machine damage or malfunction before operating the machine. Before Repairs Start: Perform disassembly procedures to the point where repairs can be completed. Then to re-assemble, perform the disassembly steps in reverse order. Symbols Legend Safety alert symbol—used to alert personnel to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Read, understand and obey the safety rules and operating instructions in the appropriate operator’s manual on your machine. Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Be sure that all necessary tools and parts are available and ready for use. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Use only Genie approved replacement parts. Read each procedure completely and adhere to the instructions. Attempting shortcuts may produce hazardous conditions. Unless otherwise specified, perform each repair procedure with the machine in the following configuration: · Machine parked on a firm, level surface · Mast in the stowed position · Key switch in the off position with the key removed · Wheels chocked Part No. 38139 Indicates a potentially hazardous situation which, if not avoided, may cause minor or moderate injury. Indicates a potentially hazardous situation which, if not avoided, may result in property damage. Indicates that a specific result is expected after performing a series of steps. Indicates that an incorrect result has occurred after performing a series of steps. Genie AWP Super Series and Genie IWP Super Series 6-1 Section 6 • Repair Procedures First Edition • Second Printing Base Assembly 4 Trace the interlock contact wires to the rear of the base. 1-1 Interlocks 5 Locate the terminal strip. AWPS models: The interlock contacts indicate proper installation of the outriggers and only allow the machine to operate when the outriggers are properly installed and adjusted. IWPS models: The base interlock switches indicate that the foot pads are in firm contact with the ground. How to Remove an Interlock Contact - AWP Models 1 Fully lower the platform. Turn the key switch off and remove the key. 6 Label and remove the contact wires by inserting a small screwdriver into the hole below the wire and gently push in while pulling on the wire. 7 Follow the wires to the grommets where the wire enters and exits the base. Pull the wires through the grommets and the base. Note: Only pull the wires out far enough to access the interlock contact bracket mounting fasteners. 8 Remove the interlock contact bracket mounting fasteners from the outrigger base socket. 2 Store the outriggers in the storage sockets. 3 Remove the rear base cover. a b c a b c 6-2 terminal strip interlock contact bracket fastener base Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures BASE ASSEMBLY How to Remove a Base Interlock Switch - IWPS Models 1 Fully lower the platform. Turn the key switch off and remove the key. 2 Pull the base lowering handle to fully lower the base. 3 Remove the foot pad switch bracket fasteners. 4 Pull the foot pad switch bracket out of the base. 1-2 Base Components - IWPS Models How to Remove the Inner Base Frame Bodily injury hazard. This procedure requires specific repair skills, lifting equipment and a suitable workshop. Attempting this procedure without these skills and tools may result in death or serious injury and significant component damage. Dealer service is strongly recommended. 1 Pull the base lowering handle to fully lower the base. 2 Attach an overhead crane to the lifting eye at the top of the mast. b a a b switch bracket fasteners switch bracket cover 5 Remove the wires from the switch. Note the wire positions. 6 Remove the fastener that attaches the switch to the switch bracket. Part No. 38139 3 Remove the mounting fastener from the lift cylinder rod end. Lift the rod end of the cylinder up and attach it to the base. 4 Tag, disconnect and plug the three hydraulic hoses from the base manifold. Cap the ports on the manifold. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. Genie AWP Super Series and Genie IWP Super Series 6-3 Section 6 • Repair Procedures First Edition • Second Printing BASE ASSEMBLY 5 Pull the hoses through the channel of the base inner frame. 4 Be sure the cable is attached to the cable mounting bracket with a lock nut on each side. There should be 1/4 to 1/2 inch / 6.35 to 12.7 mm of threads on the manifold side of the bracket. 6 From under the base, remove the inner frame support tube mounting fasteners. The tube is mounted directly under the number 1 column. 7 Carefully lift the machine off of the inner base frame. Do not allow the inner base frame to fall when lifting the machine. 5 Locate the base release cable mounting bracket on the bottom side of the number 1 column. Crushing hazard. The machine may fall, if it is not properly supported by the overhead crane when removed from the base. a b How to Adjust the Base Release Cable - IWPS Models c 1 Pull the base lowering handle to fully lower the base. d 2 Remove the cover from the base manifold. e 3 Be sure the cable is properly connected to the manual valve at the base manifold. f g a b c d e f g a d c a b c d 6-4 a b lock nut coupler base release cable cable mounting bracket number 1 column base release cable cable striker bracket slider bracket spring lock nut cable mounting bracket 6 Loosen the mounting fasteners on the cable mounting bracket and the cable striker bracket on the number 1 column. Do not remove the fasteners. Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures BASE ASSEMBLY 7 Measure from the bottom of the number 1 column, make a reference mark 6 inches / 15.2 cm up the column. 8 Slide the cable mounting bracket up, until the top of the bracket is even with the reference mark from step 7. Tighten the mounting fasteners. 9 Measure from the bottom of the number 2 column, make a reference mark 10 inches / 25.4 cm up the column. 10 Slide the cable striker bracket down until the top of the bracket is even with the reference mark from step 9. The spring will need to be compressed, when the cable striker bracket is pulled down. Tighten the mounting fasteners. 11 Pump the foot pedal to raise the base. 12 Pull the base release handle to be sure the base lowers. Adjust if necessary. How to Adjust the Foot Pump Pressure Relief Valve Component damage hazard. The work area and surfaces where this procedure will be performed must be clean and free of debris that could get into the hydraulic system and cause severe component damage. Dealer service is recommended. 1 Pull the base lowering handle to fully lower the base. 2 Tag and disconnect the hydraulic hose from the port at the rod end of the base cylinder. Cap the cylinder port. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. 3 Connect a 0 to 3000 psi / 0 to 250 bar pressure gauge to the hydraulic hose. 4 Slowly pump the foot pedal and note the pressure. Result: The pressure gauge should read 1600 psi ± 50 psi / 110 bar ± 3.4 bar. Adjust if necessary. 5 Remove the manifold cover. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 6-5 Section 6 • Repair Procedures First Edition • Second Printing BASE ASSEMBLY 6 Hold the relief valve and remove the hex cap (item J). 7 Adjust the internal hex socket. Turn it clockwise to increase the pressure or counterclockwise to decrease the pressure. Install the relief valve cap. Tip-over hazard. Do not adjust the relief valve higher than specified. 8 Repeat step 4 to confirm the relief valve setting. Re-adjust if necessary. How to Remove the Foot Pump Component damage hazard. The work area and surfaces where this procedure will be performed must be clean and free of debris that could get into the hydraulic system and cause severe component damage. Dealer service is recommended. How to Bleed the Foot Pump 1 Pull the base lowering handle to fully lower the base. 2 Place a container under the base lowering cylinder, and remove the bleed screw from the barrel-end of the base lowering cylinder. 3 Pump the foot pedal until air stops coming out of the bleed screw hole. 4 While holding the foot pedal down, install the bleed screw. 5 Release the foot pedal. 6 Clean up any oil that may have spilled. 7 Check the hydraulic oil level in the power unit tank. Add oil if necessary. 1 Pull the base lowering handle to fully lower the base. 2 Remove the linkage mounting fasteners from the foot pump. 3 Remove the foot pump from the manifold. Plug the port in the manifold. Note: The foot pump must be bled after installation. 6-6 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures BASE ASSEMBLY 1-3 Foot Pump Manifold Components IWPS Models (before serial number IWP09-8270) Index No. Description Schematic Item 1 Check valve ....................................... G ........... System pressure ................................. 8-10 ft-lbs / 11-14 Nm 2 Check valve ....................................... H ........... Directs flow to the tank 3 Manual release valve ........................ I ............ Lowers base ........................................ 8-10 ft-lbs / 11-14 Nm 4 Relief valve, 1600 psi / 110 bar ......... J ............ Base lift cylinder ................................ 35-40 ft-lbs / 47-54 Nm 5 Pilot to open check valve ................... K ........... Base lift cylinder ................................ 35-40 ft-lbs / 47-54 Nm 6 Foot pump ......................................... L ........... Base lift cylinder .................................. 8-10 ft-lbs / 11-14 Nm Function Torque G 1 H 6 2 L K 5 J 4 I 3 Plug Torque Specifications Description Hex Size Torque Description Hex Size Torque SAE No. 2 1/ 8 50 in-lbs / 6 Nm SAE No. 8 5/16 50 ft-lbs / 68 Nm SAE No. 4 3/16 13 ft-lbs / 18 Nm SAE No. 10 9/16 55 ft-lbs / 75 Nm SAE No. 6 1/ 4 18 ft-lbs / 24 Nm SAE No. 12 5/ 8 Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 75 ft-lbs / 102 Nm 6-7 Section 6 • Repair Procedures First Edition • Second Printing BASE ASSEMBLY 1-3 Foot Pump Manifold Components IWPS Models (after serial number IWP09-8269) Index No. Description Schematic Item 1 Check valve ....................................... G ........... System pressure .................................. 8-10 ft-lbs / 11-14 Nm 2 Check valve ....................................... H ........... Directs flow to the tank 3 Plug, SAE No. 4 ............................................................................................................. 12-14 ft-lbs / 17-19 Nm 4 Manual release valve .......................... J ........... Lowers base ......................................... 8-10 ft-lbs / 11-14 Nm 5 Plug, SAE No. 6 ............................................................................................................. 17-19 ft-lbs / 23-25 Nm 5 Pilot to open check valve .................... K ........... Base lift cylinder .................................. 35-40 ft-lbs / 47-54 Nm 6 Relief valve, 1600 psi / 110 bar ........... L ........... Base lift cylinder .................................. 8-10 ft-lbs / 11-14 Nm 7 Orifice, 0.3 inch / 0.76 mm .................. M........... System pressure .................................. 8-10 ft-lbs / 11-14 Nm 8 Orifice, 0.3 inch / 0.76 mm .................. M........... System pressure .................................. 8-10 ft-lbs / 11-14 Nm 9 Orifice, 0.3 inch / 0.76 mm .................. M........... System pressure .................................. 8-10 ft-lbs / 11-14 Nm 10 Orifice, 0.3 inch / 0.76 mm .................. M........... System pressure .................................. 8-10 ft-lbs / 11-14 Nm 11 Orifice, 0.3 inch / 0.76 mm .................. M........... Foot Pump Function Torque 11 2 1 3 10 8 9 7 5 6 4 6-8 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures BASE ASSEMBLY 1-4 Power Wheel Assist Manifold Components - IWPS Models (before serial number 4097-991) Index No. Description Schematic Item 1 Check valve ....................................... AA ......... System pressure ............................... 25-35 ft-lbs / 34-41 Nm 2 Solenoid valve, 2 position 3 way ....... AB ......... Reverse ............................................. 25-35 ft-lbs / 34-41 Nm 3 Solenoid valve, 2 position 3 way ....... AC ........ Forward ............................................. 25-35 ft-lbs / 34-41 Nm 4 Solenoid valve, 2 position 3 way ....... AD ........ All functions ....................................... 25-35 ft-lbs / 34-41 Nm Function Torque 1 Y32 AD AA Y5 Y6 AC 4 AB 3 2 Plug Torque Specifications Description Hex Size Torque SAE No. 2 1/8 50 in-lbs / 6 Nm SAE No. 4 3/16 13 ft-lbs / 18 Nm SAE No. 6 1/4 18 ft-lbs / 24 Nm SAE No. 8 5/16 50 ft-lbs / 68 Nm SAE No. 10 9/16 55 ft-lbs / 75 Nm SAE No. 12 5/8 Valve Coil Resistance Specifications Valve coil specifications Part No. 38139 75 ft-lbs / 102 Nm Solenoid valve, 2 position 3 way 10V DC (schematic items AB, AC and AD) Genie AWP Super Series and Genie IWP Super Series 6 to 8Ω 6-9 Section 6 • Repair Procedures First Edition • Second Printing BASE ASSEMBLY 1-5 Power Wheel Assist Manifold Components - IWPS Models (from serial number 4097-991 to 4099-2532) Index No. Description Schematic Item 1 Check valve ....................................... BA ......... System pressure ............................... 25-35 ft-lbs / 34-41 Nm 2 Solenoid Valve, 2 position 2 way ...... BB ......... All Functions ..................................... 25-35 ft-lbs / 34-41 Nm 3 Solenoid Valve, 3 position 4 way ...... BC ........ Forward/Reverse .............................. 25-35 ft-lbs / 34-41 Nm 4 Relief Valve 1600 psi / 110 bar ......... BD ........ System relief ..................................... 25-35 ft-lbs / 34-41 Nm Function Torque BA 1 BB Y32 2 BC Y5 Y6 3 BD Plug Torque Specifications Description Hex Size 4 Torque Valve Coil Resistance Specifications SAE No. 2 1/8 50 in-lbs / 6 Nm SAE No. 4 3/16 13 ft-lbs / 18 Nm SAE No. 6 1/4 18 ft-lbs / 24 Nm Valve coil specifications SAE No. 8 5/16 50 ft-lbs / 68 Nm Solenoid valve, 2 position 2 way 10V DC (schematic item BA) 6 to 8Ω SAE No. 10 9/16 55 ft-lbs / 75 Nm 5/8 Solenoid valve, 3 position 4 way 10V DC (schematic item BC) 6 to 8Ω SAE No. 12 6 - 10 75 ft-lbs / 102 Nm Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures 1-6 Power Wheel Assist Manifold Components - IWPS Models (after serial number 4099-2532) Index No. Description Schematic Item 1 Check valve ....................................... CA ........ System pressure ............................... 25-35 ft-lbs / 34-41 Nm 2 Solenoid valve, 2 position 2 way ...... CB ........ All functions ...................................... 25-35 ft-lbs / 34-41 Nm Function Torque 3 Solenoid valve, 3 position 4 way ...... CC ........ Forward/Reverse .............................. 25-35 ft-lbs / 34-41 Nm 4 Relief valve 1600 psi / 110 bar ......... CD ........ System relief ..................................... 25-35 ft-lbs / 34-41 Nm 5 Cross-port relief valve ....................... CE ........ Brake ................................................ 25-35 ft-lbs / 34-41 Nm CA 1 CB Y32 2 CC Y5 Y6 3 CD 4 CE 5 Plug Torque Specifications Description Hex Size Torque Valve Coil Resistance Specifications SAE No. 2 1/8 50 in-lbs / 6 Nm SAE No. 4 3/16 13 ft-lbs / 18 Nm SAE No. 6 1/4 18 ft-lbs / 24 Nm Valve coil specifications SAE No. 8 5/16 50 ft-lbs / 68 Nm Solenoid valve, 2 position 2 way 10V DC (schematic item CB) 6 to 8Ω SAE No. 10 9/16 55 ft-lbs / 75 Nm 5/8 Solenoid valve, 3 position 4 way 10V DC (schematic item CC) 6 to 8Ω SAE No. 12 Part No. 38139 75 ft-lbs / 102 Nm Genie AWP Super Series and Genie IWP Super Series 6 - 11 Section 6 • Repair Procedures First Edition • Second Printing Ground Control Box 2-1 How to Test the Transformer AC Models Test 1 Fully lower the platform. Turn the key switch off and disconnect the power supply. 2 Open the ground control box and locate the transformer. 3 Tag and disconnect all wiring from the transformer. 4 Connect the leads from an ohmmeter to the following terminal combinations and check the continuity/resistance. Desired result brown wire to blue wire 20 to 22Ω black wire to white wire 16 to 19Ω yellow wire to white wire 16 to 19Ω red/yellow wire to red wire #1 0.5 to 1.5Ω red/yellow wire to red wire #2 0.5 to 1.5Ω red wire #1 to red wire #2 0.5 to 1.5Ω yellow wire to black wire 0.5 to 1.5Ω all other wire combinations no continuity (infinite Ω) Genie AWP Super Series and Genie IWP Super Series Part No. 38139 a b c h g f a b c d e f g h 6 - 12 e d red wire #2 red/yellow wire red wire #1 yellow wire black wire white wire brown wire blue wire First Edition • Second Printing Section 6 • Repair Procedures GROUND CONTROL BOX 2-2 How to Test the AC Contactor AC Models Test terminal 0 to 1 all other terminal combinations 1 Fully lower the platform. Turn the key switch off and disconnect the power supply. Desired result 80 to 85Ω no continuity (infinite Ω) 2 Open the ground control box and locate the AC contactor. 3 Tag and disconnect all wiring from the contactor. 4 Connect the leads from an ohmmeter to the following terminal combinations and check the continuity/resistance. a b c d e f a b c d e f Part No. 38139 terminal terminal terminal terminal terminal terminal no. no. no. no. no. no. 1 8 6 2 4 0 Genie AWP Super Series and Genie IWP Super Series 6 - 13 Section 6 • Repair Procedures First Edition • Second Printing Hydraulic Power Unit 3-1A Hydraulic Power Unit Components - AC Models (before serial number s AWP03-27389 and IWP03-5151) Index No. Description 1 115-230V AC electric motor .............................. Single phase - 2850/3450 rpm, 50/60 Hz 2 Capacitor ........................................................... Motor start circuit 3 Relief valve ....................................................... Lift relief 4 Solenoid operated N.O. dump valve .................. Diverts pump output back to tank during motor start up 5 10V DC coil ....................................................... Activates N.O. dump valve 6 Hydraulic reservoir ............................................ 3 quarts / 2.8 liters 7 Drain plug .......................................................... Drains hydraulic tank 8 Sight gauge ....................................................... Hydraulic fluid level Function 9 Breather cap ...................................................... Hydraulic tank vent/filler 10 Suction strainer ................................................. Filters hydraulic fluid 11 O-ring ................................................................ Seals tank 12 Pump ................................................................. 0.5 to 0.6 gallons per minute at 2000 psi / 1.89 to 2.27 liters per minute at 138 bar 13 Check valve ...................................................... Pump output 14 Motor seal ......................................................... Seals motor from contaminants 15 Motor bearing ................................................... Aligns motor shaft into pump 6 - 14 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures HYDRAULIC POWER UNIT 1 2 15 14 3 13 4 Y30 5 12 11 10 9 8 6 7 Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 6 - 15 Section 6 • Repair Procedures First Edition • Second Printing HYDRAULIC POWER UNIT 3-1B Hydraulic Power Unit Components - AC Models (from serial number AWP03-27390 to AWP08-60145) Index No. Description 1 115-230V AC electric motor .............................. Single phase - 2850/3450 rpm, 50/60 Hz 2 Capacitor ........................................................... Motor start circuit 3 Motor bearing ................................................... Aligns motor shaft into pump 4 Motor seal ......................................................... Seals motor from contaminants 5 Relief valve ....................................................... Lift relief 6 Pump ................................................................. 0.5 to 0.6 gallons per minute at 2000 psi / Function 1.89 to 2.27 liters per minute at 138 bar 7 Solenoid operated N.O. dump valve .................. Diverts pump output back to tank during motor start up 8 10V DC coil ....................................................... Activates N.O. dump valve 9 O-ring ................................................................ Seals tank 10 Return tube ....................................................... Returns fluid to tank 11 Hydraulic tank ................................................... 3 quarts / 2.8 liters 12 Drain plug .......................................................... Drains hydraulic tank 13 Breather cap ...................................................... Hydraulic tank vent/filler 14 Filter pick-up screen .......................................... Filters hydraulic fluid 15 Suction tube ...................................................... Sends fluid to pump 16 Check valve ...................................................... Pump output 6 - 16 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures HYDRAULIC POWER UNIT 1 2 3 4 5 6 16 7 15 8 9 10 14 13 11 12 Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 6 - 17 Section 6 • Repair Procedures First Edition • Second Printing HYDRAULIC POWER UNIT 3-2 Hydraulic Power Unit Components - DC Models (before serial number s AWP03-27402 and IWP03-5123) Index No. Description Function 1 12V DC electric motor ...................................... 12V DC standard duty 1 terminal 180 A at 2650 psi / 183 bar 2 Motor starter solenoid ....................................... Power supply to electric motor 3 Relief valve ....................................................... Lift relief 4 Solenoid operated N.O. dump valve ................ Diverts pump output back to tank during motor start up 5 10V DC coil ....................................................... Activates N.O. dump valve 6 Hydraulic tank ................................................... 3 quarts / 2.8 liters 7 Drain plug ......................................................... Drains hydraulic tank 8 Sight gauge ...................................................... Hydraulic fluid level 9 Breather cap ..................................................... Hydraulic tank vent/filler 10 Suction strainer ................................................ Filters hydraulic fluid 11 O-ring ................................................................ Seals tank 12 Pump ................................................................ 0.7 to 1 gpm at 2000 psi / 2.6 to 3.76 L/min at 138 bar 13 Check valve ...................................................... Pump output 14 Motor seal ......................................................... Seals motor from contaminants 15 Motor bearing ................................................... Aligns motor shaft into pump 6 - 18 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures HYDRAULIC POWER UNIT 1 2 15 14 3 13 4 Y30 5 12 11 10 9 8 6 7 Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 6 - 19 Section 6 • Repair Procedures First Edition • Second Printing HYDRAULIC POWER UNIT 3-3 Hydraulic Power Unit Components - Air Powered Models (before serial number AWP04-27779) Index No. Description 1 Air motor ........................................................... 100 psi / 6.9 bar @ 80 cfm / 37760 cc/sec 2 Exhaust Muffler ................................................. Controls sound emissions 3 Relief valve ....................................................... Relief valve 4 Valve N.O. Air Pilot ........................................... Diverts pump output back to tank during motor start up Function 5 O-ring ................................................................ Seals tank 6 Tank .................................................................. 3 quarts / 2.8 liters 7 Drain plug ......................................................... Drains tank 8 Sight gauge ...................................................... Hydraulic fluid level 9 Tee fitting (models with Narrow or Rough Terrain Base Option) ............................ Tank vent adaptor 10 Plug fitting (models with Narrow or Rough Terrain Base Option) ............................ Plug 11 Suction strainer ................................................ Filters hydraulic fluid 12 Breather cap (after serial number 3897-4544) ....................... Tank vent/filler 13 Breather cap (before serial number 3897-4545) .................... Tank vent/filler 14 Check Valve ..................................................... Pump output 15 Pump ................................................................ 0.7 to 1 gpm at 2000 psi / 2.6 to 3.76 L/min at 138 bar 16 Pump/Motor Adaptor Housing .......................... Protects coupling components 17 Pump adaptor ................................................... Connects pump to spider coupler 18 Spider coupler .................................................. Connects motor to pump 19 Motor adaptor ................................................... Connects motor to spider coupler 6 - 20 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures HYDRAULIC POWER UNIT 1 2 19 18 17 16 3 15 14 4 13 5 12 11 10 9 6 8 7 Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 6 - 21 Section 6 • Repair Procedures First Edition • Second Printing HYDRAULIC POWER UNIT 3-4 Hydraulic Power Unit How to Remove the Hydraulic Power Unit - AC Models 1 Fully lower the platform, turn the key switch off and remove the key and disconnect the power supply. 6 Remove the cover from the junction box on the motor. Tag and disconnect the electrical wiring in the junction box. Loosen the squeeze connector on the junction box and pull the wiring out through the squeeze connector. DC models: Tag and disconnect the electrical wiring from the starter solenoid. Air models: Tag and disconnect the pneumatic hoses from the power unit 2 IWPS models: Pull the base lowering handle to fully lower the base. 7 Support the hydraulic power unit with a lifting device. 3 Remove the power unit cover. 8 Remove the power unit mounting fasteners, then remove the power unit from the machine. 4 Tag, disconnect and plug the hydraulic hoses. Cap the fittings on the power unit. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. Crushing hazard. The power unit will fall unless it is properly supported. Note: If a new power unit is installed, the pressure relief valve must be properly adjusted. See 3-6, How to Adjust the Pressure Relief Valve. 5 Tag and disconnect the electrical wiring from the valve coil. 6 - 22 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures HYDRAULIC POWER UNIT How to Remove the Hydraulic Power Unit - DC Models 1 Fully lower the platform. Turn the key switch off and remove the key and disconnect the power supply. 2 IWPS models: Pull the base lowering handle to fully lower the base. 3 Remove the power unit cover. 4 Tag, disconnect and plug the hydraulic hoses. Cap the fittings on the power unit. 9 Rotate the mounting plate away from the mast to access the power unit mounting fasteners. 10 Remove the power unit mounting fasteners. Remove the power unit from the machine. Crushing hazard. The power unit will fall unless it is properly supported. Note: If a new power unit is installed, the pressure relief valve must be properly adjusted. See 3-6, How to Adjust the Pressure Relief Valve. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. 5 Tag and disconnect the electrical wiring from the valve coil. 6 Tag and disconnect the electrical wiring from the motor start solenoid. 7 Support the hydraulic power unit with a lifting device. 8 Loosen the power unit mounting plate mounting fasteners. Do not remove them. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 6 - 23 Section 6 • Repair Procedures First Edition • Second Printing HYDRAULIC POWER UNIT How to Remove the Hydraulic Power Unit - Air Models 3-5 Hydraulic Pump 1 Fully lower the platform, turn the key switch off and remove the key and disconnect the power supply. How to Remove the Hydraulic Pump 2 Tag, disconnect and plug the hydraulic hoses. Cap the fittings on the power unit. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. 3 Support the hydraulic power unit with a lifting device. Note: When removing a hose assembly or fitting, the O-ring on the fitting and/or hose end must be replaced and then torqued to specification during installation. Refer to Section Two, Hydraulic Hose and Fitting Torque Specifications. 1 Fully lower the platform, turn the key switch off and remove the key. 2 IWPS models: Pull the base lowering handle to fully lower the base. 3 Remove the power unit cover. 4 Loosen the power unit mounting plate mounting fasteners. Do not remove them. 4 Remove the power unit. See 3-4, How to Remove the Power Unit. 5 Rotate the mounting plate away from the mast to access the power unit mounting fasteners. 5 Support the hydraulic tank with a lifting device. 6 Remove the power unit mounting fasteners. Remove the power unit from the machine. Crushing hazard. The power unit will fall if it is not properly supported when it is removed from the machine. Note: If a new power unit is installed, the pressure relief valve must be properly adjusted. See 3-6, How to Adjust the Pressure Relief Valve. 6 Remove the mounting fasteners from the tank. Remove the tank from the power unit. Do not allow the hydraulic oil to spill. Note: It may be necessary to tap the side of the tank with a soft rubber mallet to loosen it. 7 Remove the mounting fastener from the suction cover assembly on the pump. Then remove the suction cover. 8 Remove the mounting fasteners from the pump. Then remove the pump from the power unit. Note: When installing the tank, be sure not to damage the o-ring. 6 - 24 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures HYDRAULIC POWER UNIT 3-6 Valve Adjustment 11 Hold the relief valve screw and tighten the lock nut. Be sure the relief valve screw does not turn. How to Adjust the Platform Lift Relief Valve 12 Remove the weight from the platform. Note: Be sure the hydraulic oil level is between the FULL and ADD marks on the oil level indicator. 1 Remove the power unit cover. 2 Loosen the locknut on the relief valve located on the right side of the motor. 3 Follow the appropriate operator's manual to set up the machine for operation. 4 Place the maximum rated load into the platform. Secure the load to the platform. See specifications, Section 2. 13 Bleed the hydraulic system by raising the platform to full height. If the pump cavitates or platform fails to reach full height, add hydraulic oil until the pump is functioning correctly. Do not overfill the hydraulic tank. Component damage hazard. Do not continue to operate the machine if the hydraulic pump is cavitating. 14 Install the breather cap and the power unit cover. 5 Hold the relief valve screw and loosen the lock nut. 6 While activating the platform up function, turn the relief valve screw clockwise, just until the platform begins to raise. 7 Fully lower the platform. 8 Add an additional 30 pounds / 14 kg to the platform. Secure the additional weight. 9 Activate the platform up function. 10 The power unit should not be able to lift the platform. If the power unit lifts the platform, turn the relief valve counterclockwise until the platform does not lift. Repeat steps 11 and 12 until the lift relief valve is properly adjusted. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 6 - 25 Section 6 • Repair Procedures First Edition • Second Printing HYDRAULIC POWER UNIT 3 Connect 12V DC to the small post and a ground wire to the case of the solenoid, then test the following terminal combinations. 3-7 How to Test the Motor Start Solenoid - DC Models Test Electrocution hazard. Contact with electrically charged circuits may result in death or serious injury. Remove all rings, watches and other jewelry. 2 large posts Desired result continuity (zero Ω) Electrocution hazard. Disconnect the ground cable from the battery before performing this procedure. 1 Tag and disconnect all wiring from the motor start solenoid. 2 Connect the leads from an ohmmeter to the following terminal combinations and check the continuity/resistance. Test Desired result Small post to ground 13 to 17Ω 2 large posts no continuity (infinite Ω) a b a b 6 - 26 a high amp power terminal (large posts) solenoid coil terminal (small post) Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures Power Pack 9 Tag, disconnect and plug the hydraulic hoses from the power unit. 4-1 Power Pack How to Change a Power Pack 1 Fully lower the platform. Turn the key switch off and disconnect the machine from the power supply. IWP models: Pull the base lowering handle to lower the base. 2 Remove the power unit cover. 3 AC and DC models: Separate both control cable quick disconnect couplers from the ground control box. Air models: Disconnect the air lines from the air valve container, filter regulator and air lubricator. 4 AC and DC models: Separate the battery quick disconnects. 5 DC models: Disconnect the battery cables from the motor start solenoid. 6 AWPS models with Narrow Base or Rough Terrain Base: Remove the loading wheels. 8 Remove the breather cap from the hydraulic power unit and install a pipe plug in the filler hole. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. 10 Support the power pack and remove the power pack mounting bolts. Crushing hazard. The power pack will fall if not properly supported when removed from the machine. 11 Remove the power pack. Installation To assemble, reverse the disassemble steps. Tip-over hazard. On Narrow Base and Rough Terrain Base models, the counterweights must be installed on the new power pack. Component damage hazard. Do not overtighten the hydraulic fittings. Note: Do not install the motor cover until the relief valve adjustment is complete. Refer to 3-6, How to adjust the Pressure Relief Valve. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 6 - 27 Section 6 • Repair Procedures First Edition • Second Printing Mast Components AWP-15S AWP-20S AWP-25S & AWP36S AWP-30S & AWP40S Mast Components a carriage b number 3 column c number 2 column d number 1 column e number 3 column idler wheel assembly f number 2 column idler wheel assembly 6 - 28 REV B g h i j k l number number number number number number AWP Super Series • IWP Super Series 4 4 5 5 6 6 column idler wheel assembly column column column idler wheel assembly column idler wheel assembly column Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures MAST COMPONENTS REV B 5-1 Lift Cylinder How to Remove the Lift Cylinder Bodily injury hazard. This procedure requires specific repair skills, lifting equipment and a suitable workshop. Attempting this procedure without these skills and tools may result in death or serious injury and significant component damage. Dealer service is strongly recommended. 4 Lift the machine off the ground then while lowering it, guide it over onto the saw horse. Before the platform reaches the ground, place a saw horse under the mast above the platform. Lower the machine onto the saw horse. Be sure the saw horse is of ample capacity. Note: When removing a hose assembly or fitting, the O-ring on the fitting and/or hose end must be replaced and then torqued to specification during installation. Refer to Section Two, Hydraulic Hose and Fitting Torque Specifications. Crushing hazard. The machine will fall unless it is properly supported by the saw horse. 1 Fully lower the platform. Turn the key switch to the off position.. 5 Remove the socket head retaining bolt from the clevis block on the lift cylinder rod end. AWPS models: Remove the outriggers from the outrigger storage socket. a DC models: Remove the battery pack. 2 Remove the breather cap from the hydraulic power unit and install a pipe plug in the filler hole. b c 3 Attach an overhead crane to the lifting eye at the top of the mast. a b c Part No. 38139 AWP Super Series • IWP Super Series top of no. 1 column retaining fastener clevis block 6 - 29 Section 6 • Repair Procedures First Edition • Second Printing MAST COMPONENTS REV B 6 Tag, disconnect and plug the lift cylinder hydraulic hoses. Cap the fittings on the lift cylinder. 5-2 Mast Assembly Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. 7 Remove the cylinder mounting fasteners from the barrel end of the cylinder. 8 Loosen the cylinder mounting bracket fasteners. a How to Remove the Mast Assembly - AWPS Models Bodily injury hazard. This procedure requires specific repair skills, lifting equipment and a suitable workshop. Attempting this procedure without these skills and tools may result in death or serious injury and significant component damage. Dealer service is strongly recommended. 1 Fully lower the platform. Turn the key switch to the off position and remove the key. 2 Remove the platform. See 7-1, How to Remove an Aluminum Platform. d 3 Remove the power pack. See 4-1, How to Change a Power Pack. c 4 AWP-36S and 40S models: Remove the tiltback frame. See 6-1, How to Remove the Tiltback Frame. b a b c d bracket mounting fasteners cylinder mounting fasteners hydraulic cylinder cylinder mounting plate 5 Attach an overhead crane to the lifting eye at the top of the mast. 9 Support the cylinder and carefully slide it out of the bottom of the mast. Crushing hazard. The lift cylinder will fall unless it is properly supported. 6 - 30 AWP Super Series • IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures REV B MAST COMPONENTS 6 Place a saw horse in front of the machine where the top of the mast will rest. 12 Remove the mast brace mounting bracket fasteners. 7 Lift the machine off the ground and then while lowering it, guide it over onto the saw horse. Be sure the saw horse is of ample capacity. 13 Remove the four mast mounting fasteners. Push the fasteners toward the mast for clearance during mast removal. 14 AWP-15S, 20S, 25S, and 30S models: Remove the power cable brackets from the side of the mast. AWP-36S and 40S models: Remove the rubber grommet from the access hole in the mast stiffener. Carefully pull the electrical cables and hydraulic hoses down and out through the bottom of the mast. Crushing hazard. The machine will fall unless it is properly supported by the saw horse. 8 Attach the overhead crane to the base. 9 Lift the base until the mast is level then place a second saw horse under the mast near the base. Lower the mast onto the saw horse. 15 Attach an overhead crane to the base. 16 Carefully lift and remove the base from the mast. Do not damage the lift cylinder hydraulic fittings when removing the base. Crushing hazard. The base will fall unless it is properly supported when it is removed from the mast. 10 Remove the cover on the rear of the base. 11 Tag, disconnect and plug the lift cylinder hydraulic hoses. Remove the flow control valve from the cylinder. Cap the cylinder ports. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. Part No. 38139 AWP Super Series • IWP Super Series 6 - 31 Section 6 • Repair Procedures First Edition • Second Printing MAST COMPONENTS REV B How to Remove the Mast Assembly - IWPS Models 9 Attach an overhead crane to the lifting eye at the top of the mast. 10 Remove the four mast mounting fasteners. This procedure requires specific repair skills, lifting equipment and a suitable workshop. Attempting this procedure without these skills and tools may result in death or serious injury and significant component damage. Dealer service is strongly recommended. 1 Fully lower the platform. Turn the key switch off and remove the key. 11 Carefully lift the mast out of the base. Crushing hazard. The mast will fall unless it is properly supported when it is removed from the base. 12 Place two saw horses under the mast. 13 Lower the mast onto the saw horse with the carriage facing down. 2 Pull the base lowering handle to fully lower the base. 3 Remove the platform. See 7-1, How to Remove an Aluminum Platform. 4 Remove the power pack. See 4-1, How to Change a Power Pack. 5 Tag, disconnect and plug the lift cylinder hydraulic hoses. Cap the cylinder ports. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. 6 Remove the level sensor assembly mounting fasteners. 7 Remove the base lowering cable mounting fasteners from the side of the mast. 8 Disconnect the control cable tension spring. 6 - 32 AWP Super Series • IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures REV B MAST COMPONENTS How to Disassemble the Mast Bodily injury hazard. This procedure requires specific repair skills, lifting equipment and a suitable workshop. Attempting this procedure without these skills and tools may result in death or serious injury and significant component damage. Dealer service is strongly recommended. 1 Remove the mast. See 5-2, How to Remove the Mast Assembly. 2 Remove the mounting fasteners from the cylinder mounting plates. 3 Remove the socket head retaining fastener from the clevis block on the lift cylinder rod end. 6 Remove the mast covers. 7 Remove the cover from the platform control box. Remove the control box mounting fasteners. 8 Remove the control box and control cable and set them aside. 9 IWPS models: Remove the base lowering cable bracket from the mast. 10 Remove the adjustment nuts from all of the sequencing cables. 11 Slide the carriage towards the top of the mast assembly enough to remove the tension on the lifting chain. 12 Slide the column below the carriage toward the top of the mast about 6 inches / 15.2 cm to access the idler wheel mounting fasteners. 13 Hold the idler wheel axle from turning by placing a screwdriver in the hole of the axle. Remove the axle mounting fasteners and remove the idler wheel assembly. a b Be sure to label the location and orientation of each idler wheel assembly. c a b c top of no. 1 column retaining fastener clevis block 4 Support the cylinder and carefully slide the lift cylinder out from the bottom of the mast. 5 Carefully rotate the mast until the carriage is facing up. Part No. 38139 14 Remove the adjustment nuts from the chain tension rocker on the carriage. 15 Slide the carriage out the bottom of the mast assembly. 16 Lay the chains out on the floor at the top of the mast. Do not allow the chains to become twisted or dirty. 17 Remove the adjustment nuts from the chain tension rocker on the column. AWP Super Series • IWP Super Series 6 - 33 Section 6 • Repair Procedures First Edition • Second Printing MAST COMPONENTS REV B 18 Slide the column out the bottom of the mast. 19 Push the next column toward the top of the mast to access the idler wheel assembly mounting fasteners. 20 Hold the idler wheel axle from turning by placing a screwdriver in the hole of the axle. Remove the axle mounting fasteners, and remove the idler wheel assembly. 21 Remove the adjustment nuts from the chain tension rocker on the column. 22 Slide the column out the bottom of the mast. 23 Repeat steps 19 through 22 for each remaining column. Note: If the chains are removed, mark the location and label each chain before removal. How to Assemble the Mast Bodily injury hazard. This procedure requires specific repair skills, lifting equipment and a suitable workshop. Attempting this procedure without these skills and tools may result in death or serious injury and significant component damage. Dealer service is strongly recommended. 1 Thoroughly clean all columns. 2 Secure the number 1 column to the saw horses and lay the chains out on the floor at the top. Do not allow the chains to become twisted or dirty. 4 Slide the number 2 column into the number 1 column. 5 Lay the number 2 column chains on the floor. Do not allow the chains to become twisted or dirty. 6 Lay the number 1 column chains inside the number 2 column. 7 Slide the number 3 column into the number 2 column. 8 When the number 3 column is almost all the way in, guide the number 1 column chains into the chain tension rocker on the number 3 column. 9 Install the adjustment nuts on the number 1 column chains. Tighten the adjustment nuts until the lifting chains have equal tension and the chain tension rocker is centered in the inspection hole in the column. 10 Lay the number 3 column chains on the floor. Do not allow the chains to become twisted or dirty. 11 Lay the number 2 column chains inside the number 3 column. 12 Follow steps 4 through 11 for each remaining column and the carriage. 13 After all the columns are assembled, the idler wheel assemblies can be installed. 14 Remove the tension from the lifting chains on the number 2 column by pushing the number 3 column towards the top of the mast. 3 Apply a generous amount of Boe-lube wax (Genie part number 90337) to the inside and outside channels of each column. 6 - 34 AWP Super Series • IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures REV B MAST COMPONENTS 15 Install the idler wheel assembly into the top of the number 2 column. Securely tighten the mounting fasteners. Do not over tighten. 5-3 Glide Pads Note: Confirm that all idler wheels rotate with no excessive side movement. Confirm that they do not rub on the inside of the column. Replace worn spacers if necessary. Refer to Maintenance procedure C-2, Inspect the Mast Assembly for Wear. How to Adjust the Glide Pads Specification Side movement, Maximum 0.079 inch 2 cm 16 Repeat steps 14 and 15 for each remaining idler wheel assembly. 17 Confirm that all of the idler wheel axle mounting fasteners are flush with the column. 1 Fully lower the platform, turn the key switch off and remove the key. 2 Locate the upper and lower glide pad adjustment bolts below each upper roller bolt on both sides of each column. 3 Hold the glide pad bolt and loosen the lock nut on all the glide pads. 4 Turn all the glide pad adjustment bolt clockwise until the glide pad makes contact with the column. Adjust the slide pads on both sides of all column mast. Be sure the sides of the columns are even to within 1/8 inch / 3.17 mm of each other. Component damage hazard. The roller wheels may be damaged if the idler wheel axle mounting fasteners are not flush with the column. 18 Install the mast assembly on the base. 19 Adjust the lifting chains. See 5-4, How to Adjust the Lifting Chains. Note: IWPS Models: Adjust the base release cable. See 1-2, How to Adjust the Base Release Cable. Part No. 38139 AWP Super Series • IWP Super Series 6 - 35 Section 6 • Repair Procedures First Edition • Second Printing REV B MAST COMPONENTS 5 Starting at the number 1 column, torque the upper and lower glide pad bolts to 12 in-lbs / 1.35 Nm. Hold the glide pad adjustment bolt and tighten the lock nut. Be sure the glide pad bolt does not turn. 5-4 Lifting Chains 6 Repeat step 5 for each remaining upper and lower glide pad on both sides of the mast. Start at the number 1 column and work toward the carriage. 1 Fully lower the machine and check to see if all the columns (except the carriage) are even at the top. The chains are adjusted correctly if all the columns are even at the top. 7 Repeat step 5 for all of the upper and lower glide pads. To adjust column chains: Note: Make sure glide pad bolts are adjusted evenly on each side to maintain squareness of the columns. How to Adjust the Lifting Chains 2 Mark the column to be adjusted. 3 Raise the platform 6 feet / 2 m. 4 Turn the adjustment lock nuts evenly on both chain terminals clockwise to raise the column or counterclockwise to lower the column. 5 Fully lower the machine and confirm the alignment of the columns. Adjust if necessary. 6 Confirm that the chain terminals on each column have equal tension and the lock nuts are tight. 6 - 36 AWP Super Series • IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures REV B MAST COMPONENTS This page intentionally left blank. Part No. 38139 AWP Super Series • IWP Super Series 6 - 37 Section 6 • Repair Procedures First Edition • Second Printing MAST COMPONENTS REV B How to Inspect the Lifting Chains Inspection Procedure Inspection Failure Inspection Remedy Wear Count out 16 chain links and measure pin to pin centerline dimension with a steel measuring tape. When the length of the 16 links (pin to pin) measure more than 8.25 inches / 21 cm for 1/2 inch / 12.7mm chain or 10.31 inches / 26.1 cm for 5/8 inch / 15.9 mm chain. Replace both chains on that column. Replace entire chain. Do not repair just the affected portion of the chain. Visually inspect the chains for rust and corrosion. Evidence of rust or corrosion. Remove chain and inspect for cracked plates (see inspection of cracked plates). If no cracks are found, lubricate chain with motor oil (SAE 40) and install chain. Visually inspect the chains for lubrication. When external surfaces are not protected with a layer of oil. Lubricate chain with motor oil (SAE 40W). Inspect chain link joints for easy movement. Joints that do not flex freely or are binding. If rust and corrosion is found, refer to Failure Remedy for rust and corrosion. Note: Measure a section of chain that moves over the idler wheels. Rust and Corrosion Tight Joints If link plates or pins are bent or deformed, replace entire chain. Replace both chains on that column. Do not repair just the affected portion of the chain. 6 - 38 AWP Super Series • IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures MAST COMPONENTS REV B Inspection Procedure Inspection Failure Inspection Remedy Raised or Turned Pins Visually inspect for raised pins. Raised pins. Replace both chains on that column section. Do not repair just the affected portion of the chain. Visually inspect for turned pins by insuring all the flats on the "V" heads are aligned. Misalignment of flats on all "V" heads. Replace both chains on that column section. Do not repair just the affected portion of the chain. Visually inspect for wear patterns on heads of link pins and outside link plates where they contact the idler wheel. Wear on pin heads or noticeable wear in the profile of the outside link plate. Replace both chains on that column section. Do not repair just the affected portion of the chain. Chain Side Check alignment of chain anchors and idler wheels. link plate wear Chain Anchors chain anchors Idler Wheels Visually inspect chain anchors. threaded rod Visually inspect chain idler wheels. idler wheel Cracked Link Plates Part No. 38139 Visually inspect chain link plates for cracks. Broken chain anchor fingers. Replace chain anchor. Bent or damaged anchor. Replace chain anchor. Twisted or misaligned chain anchor. Re-align chain anchor to ensure even loading of chain. Threaded rod not visible in inspection hole. Replace chain anchor and threaded rod. Idler wheels have badly worn flanges. Replace idler wheel and check chain alignment. Idler wheels have grooves worn into chain contact surface. Replace idler wheel. Cracks in any chain link plate. Replace both chains on that column section. Replace entire chain. Do not repair just the affected portion of the chain. AWP Super Series • IWP Super Series 6 - 39 Section 6 • Repair Procedures First Edition • Second Printing Tilt-back Frame, AWP-36S and 40S Models 6-1 Tilt Back Frame How to Remove the Tilt-back Frame 1 Fully lower the platform Turn the key switch off and remove the key. 2 Maintain a firm grasp on the tilt-back frame and remove the retaining pin. Lower the tilt-back frame to the ground. 3 Remove the fasteners that mount the tilt-back frame hinges to the base. a Note: Note the amount of shims used between the hinges and the base. 4 Remove the frame from the machine. b e How to Adjust the Loading Pivot or Stop Bracket c Note: Check for side-to-side movement of the pivot slider or stop bracket. They should have no side-toside clearance and not be too tight to cause dragging or binding. Adjust if necessary. 1 Remove the tilt-back frame. See 6-1, How to Remove the Tilt-back Frame. d 2 Remove the mounting fasteners from the tilt-back frame hinges. 3 Slide the pivot slider and the stop bracket out of the frame and add shims as necessary to obtain zero clearance and zero drag. a b c d e 6 - 40 shock absorber assembly tilt-back frame shock absorber mounting bolt loading pivot bar loading stop bracket Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures TILT-BACK FRAME - AWP-36S AND 40S How to Disassemble the Shock Absorber Assembly 1 Fully lower the platform. Turn the key switch off and remove the key. 2 Maintain a firm grasp on the tilt-back frame and remove the retaining pin. Lower the tilt-back frame to the ground. 3 Remove the fastener that mounts the shock absorber assembly to the frame. e 4 Remove the shock absorber assembly from the frame and separate the lower tube from the assembly. a 5 Pull the shock absorber out of the upper tube. d 6 Remove the metric nut from each end of the shock absorber and remove the mounting blocks. Bodily injury hazard. Contents of the shock absorber are under pressure. Use care during removal. c b a b c d e Part No. 38139 shock absorber lower shock mounting block lower tube upper tube upper shock mounting block Genie AWP Super Series and Genie IWP Super Series 6 - 41 Section 6 • Repair Procedures First Edition • Second Printing Platform 7-1 Platforms How to Install a Fiberglass Platform How to Remove an Aluminum Platform 1 Place support blocks between the platform and base. Lower the platform onto the blocks. Crushing hazard. Keep away from the lowering platform. 2 Remove the mounting fasteners from the platform. 3 Pull the platform away from the mast and remove it from the machine. Bodily injury hazard. Safety decals are essential to safe machine operation. Failure to replace all safety and instructional decals could result in death or serious injury. If a platform must be replaced, be sure that all appropriate safety and instructional decals are applied to the new platform. 6 - 42 1 Remove the aluminum platform. See 7-1, How to Remove an Aluminum Platform. 2 Support the platform with a lifting device, place the platform against the mounting angles. 3 Install the mounting fasteners. Bodily injury hazard. Safety decals are essential to safe machine operation. Failure to replace all safety and instructional decals could result in death or serious injury. If a platform must be replaced, be sure that all appropriate safety and instructional decals are applied to the new platform. Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures PLATFORM 7-2 Platform Control Box How to Test Power to Platform GFCI outlet How to Test the Contacts 1 Fully lower the platform. Turn the key switch off and remove the key. 1 Fully lower the platform. Turn the key switch off and disconnect the power supply. 2 AC and DC models: Be sure the AC power supply is properly connected. 2 Remove the platform control box cover fasteners and open the control box. 3 Connect a volt meter or a small electric powered tool to the platform GFCI receptacle. 3 Note the markings on the contact to be tested. N.O. designates the contact as normally open. N.C. designates the contact as normally closed. 4 Confirm the voltage or test the electric powered tools operation. 4 Connect a continuity tester to the exposed screw terminals. Result: Normally open contacts should read no continuity. Normally closed contacts should read continuity. 5 Push the small triangular button on the top of the contactor. Result: Normally open contactor should read continuity. Normally closed contacts should read no continuity. Part No. 38139 Result: The voltage should be 115V AC nominal or the electric powered tool should operate normally. 5 Push the black TEST button on the GFCI receptacle. Result: The voltage should be 0V or the electric powered tool should not operate. 6 Push the red RESET button on the GFCI receptacle. Result: The voltage should be 115V AC nominal or the hand tool should operate normally. Genie AWP Super Series and Genie IWP Super Series 6 - 43 Section 6 • Repair Procedures First Edition • Second Printing PLATFORM 7-3 Platform Outreach Chain How to Adjust the Platform Outreach Chain, IWP-20S Models How to Replace the Outreach Chain, IWP-20S Models 1 Fully lower the platform. Turn the key switch off. 2 Fully lower the base and disconnect the power supply and remove the key. 1 Fully lower the platform. Turn the key switch off and remove the key. 3 Remove the platform. See 7-1, How to Remove an Aluminum Platform. 2 Fully extend the platform outreach. Lock the handle in position. 4 Remove the platform control box cover fasteners and open the control box. 3 Place a block of wood between the carriage and the platform outreach to prevent the outreach from collapsing when the fasteners are loosened. 5 Remove the platform control box mounting fasteners. Remove the platform control box and set it aside. Crushing hazard. The platform outreach will collapse it is not properly supported when the fasteners are loosened. 4 Locate the lower sprocket housing fasteners. 5 Loosen but do not remove both sprocket housing fasteners. 6 Push downward on the sprocket housing to remove excess slack from the chain. 7 Tighten the sprocket housing fasteners. 8 Confirm proper chain adjustment. Refer to maintenance procedure B-12, Check the Chain Adjustment. 6 - 44 6 Extend the outreach approximately 14 inches /36 cm. Lock the handle in position. 7 Attach a overhead crane to the center brace pivot pin on the outreach assembly. 8 Remove the assembly mounting fasteners. Crushing hazard. When the mounting fasteners are removed, the platform outreach will become unbalanced and may fall if it is not properly supported. 9 Lay the outreach assembly onto a workbench or table of ample capacity. Be sure the chain is facing up. Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 6 • Repair Procedures PLATFORM 10 Place a block of wood under the inner frame assembly for support while removing the chain. Crushing hazard. The platform outreach will collapse if it is not properly supported when the chain is removed. 11 Remove the lower sprocket housing mounting fasteners. Do not allow the chain to become twisted. 12 Remove the upper sprocket housing mounting fasteners. Do not allow the chain to become twisted. 13 Remove the fasteners from the outreach locking bracket. 14 Slide the platform mount off the inner frame extension arms and set it aside. 23 Thread the chain through the upper sprocket housing over the sprocket, then back through the housing. 24 Thread the chain through the lower sprocket housing over the sprocket, then back through the housing. Don't allow the chain to become twisted. 25 Do not re-use the old master link. Install a new master link. 26 Slide the platform mount onto the extension arms. 27 Install the outreach locking bracket on the platform mount. 28 Install the upper sprocket housing to the platform mount. 15 Locate the two allen head screws in the platform mount slide pad. Note: When fasteners are installed, be sure the center bolt is in between the two chains inside the housing. 16 Remove the roller from the same side of the slide pad. 29 Pull the slack out of the chain by pushing down on the lower sprocket housing. 17 Remove the two allen head screws. 30 Install the lower sprocket housing fasteners. 18 Remove the master link from the chain. 31 Adjust the chain. See procedure 7-3 above, How to Adjust the Platform Outreach Chain. 19 Pull the chain out of the slide pad and both sprocket housings. 32 Install the outreach assembly onto the carriage. 20 Install the new chain through the slidepad. 21 Push the chain through the slide pad until approximately 2 inches / 5 cm of the chain is extended past the slide pad. 22 Install the two allen head screws. Install the roller wheel. Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 6 - 45 Section 6 • Repair Procedures First Edition • Second Printing PLATFORM This page intentionally left blank. 6 - 46 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 7 • Schematics Schematics About This Section There are two groups of schematics in this section. An alpha numeric legend and wire color legend for each schematic is located on the fold of the opposing page. Observe and Obey: Electrical Schematics Electrocution hazard. Contact with electrically charged circuits may result in death or serious injury. Remove all rings, watches and other jewelry. Troubleshooting and repair procedures shall be completed by a person trained and qualified on the repair of this machine. Immediately tag and remove from service a damaged or malfunctioning machine. Hydraulic Schematics Repair any machine damage or malfunction before operating the machine. Bodily injury hazard. Spraying hydraulic oil can penetrate and burn skin. Loosen hydraulic connections very slowly to allow the oil pressure to dissipate gradually. Do not allow oil to squirt or spray. Before Troubleshooting: Read, understand and obey the safety rules and operating instructions printed in the Genie AWP Super Series Operator's Manual and the Genie IWP Super Series Operator's Manual. Be sure that all necessary tools and test equipment are available and ready for use. General Repair Process Identify symptoms Malfunction discovered Troubleshoot problem still exists Return to service Part No. 38139 problem solved Inspect and test Genie AWP Super Series and Genie IWP Super Series Perform repair 7-1 Section 7 • Schematics First Edition • Second Printing Electrical Components Item Description Genie Part Number Manufacturer Manufacturer Part Number Qty B2 .................. Battery, 130AH, 12V DC ............. 75442 ......... Trojan Battery Co. ................ SCS 225 DRY .............. 1 B4 .................. Battery, Size AA, 1.5V ................ 38018 ......... Wesco .................................. AA 1.5 Alkaline 815 ...... 8 CB4 ............... Circuit breaker, 15A,110V .......... 38020 ......... H D Cambell ......................... 1140-G111-P1M1-15.0 1 CB4 ............... Circuit breaker, 15A, 220V CE .. 38021 ......... H D Cambell ......................... 1140-G151-P7M1-8.0 .. 1 *F1 ................ Fuse, 5A ..................................... 69864 ......... Avnet .................................... ATC-5 ........................... 1 *F1 ................ Fuse, 5A ..................................... 35039 ......... Wesco .................................. AGC5 ........................... 1 KS1 ............... Contact - key switch, N.O. .......... 33320 ......... H D Cambell ......................... ZA2-BG2 ...................... 1 LS1 ................ Contact - limit switch, N.C. ......... 46409 ......... H D Cambell ......................... #XCK-P110H7 .............. 1 P1 .................. Contact, N.C. .............................. 33321 ......... H D Cambell ......................... ZA2-BT4 ....................... 1 P2 .................. Contact, N.C. .............................. 35613 ......... H D Cambell ......................... ZA2-BS44 ..................... 1 P3 .................. Contact, N.C. .............................. 33321 ......... H D Cambell ......................... ZA2-BT4 ....................... 1 QD1 ............... Battery connector ....................... 19436 ......... Anderson .............................. 6325-G1 ....................... 1 Y5, Y6, .......... Coil, 10V DC ............................... 46215 ......... Hydra Power Systems ......... 6301010 ....................... 2 Y7 .................. Coil, 10V DC ............................... 40417 ......... Hydra Power Systems ......... 10148-53 ...................... 1 Y30 ................ Coil, 10V DC ............................... 40319 ......... Monarch Hydraulics ............. 07277 ........................... 1 Y32 ................ Coil, 12V DC ............................... 21444 ......... Hydraulic Components ........ 321362 ......................... 1 * F1 * NOTE: The AWP Super Series Models were produced using two different fuses on the PC Board in the ground control box. A serial number break is not available. Refer to the specific PC board to determine the correct fuse type. 7-2 Genie AWP Super Series and Genie IWP Super Series Part No. 38139 First Edition • Second Printing Section 7 • Schematics Symbols Legend WH Electrical Symbols Wire with description N.C. N.C.H.O. M5 M5 Motor Limit Switch SW24 LIFT ENABLE Led + - Circuits crossing no connection 8 AA Batteries Toggle Switch Connection with no terminal Red Emergency Stop Button Lift Enable + - Diode U12 Thermal Device 12V Battery(s) Switch Solenoid Valve Solenoid Valve with Diode CB1 Connector Part No. 38139 F1 Fuse Circuit Breaker Genie AWP Super Series and Genie IWP Super Series 7-3 Section 7 • Schematics First Edition • Second Printing ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) D5 EN GND KS1 L L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD1 = Battery quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 4 pole 8 pin W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve M5 *N17 N.C. N.O P QD SW U W Y WIRE COLOR LEGEND Color BL BK GN/YL OR RD WH WH/BK 7-4 Description Blue Black Green/Yellow Orange Red White White/Black Note: Use these 2 legends for the schematic on the opposing page. Î Genie AWP Super Series and Genie IWP Super Series Part No. 38139 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC Models (from serial number 3896-101 to 3896-300) M L K J I H G F E D C B A 1 P1 EMERGENCY STOP BK BK BK N.C. RD KS1 BK GROUND/ PLATFORM BK 1 BK N.O. + W3 16.0V DC INPUT 1 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 14 FRONT LEFT 2 2 3 LEVELING INDICATORS L5 L14 L12 BK L7 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN N.O. WH WH 4 5 LED 13 REAR RIGHT 6 LED 15 REAR LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 UP SIGNAL OUTPUT 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 POWER INDICATOR L6 U10 2 WH OR BL RD BK RD RD GN/YL 3 RD OR W4 PC BOARD GN/YL RD 3 LED 12 FRONT RIGHT LOW BATTERY 8 AA BATTERIES SW12 LEVELING INDICATOR INPUTS FOR L15 L13 INDICATOR AUXILIARY LOWERING B4 4 P2 EMERGENCY STOP RD WH N.C. GN/YL TERMINAL STRIP + OR BL WH WH GN/YL BK GROUND STUD B2 BATTERY 12V DC - RD RD BK BK FRONT LEFT INTERLOCK BK BK BK W6 7 TO BASE MOTOR CONTACTOR 1 2 3 4 5 6 7 BK M5 MOTOR 7 REAR RIGHT INTERLOCK QD1 BATTERY CONNECTOR 6 SW16 BK 7 5 REAR LEFT INTERLOCK 6 4 SW15 4 3 FRONT RIGHT INTERLOCK 3 RD 2 QUICK DISCONNECT B WH Y30 N.O. DUMP VALVE RD RD BL RD OR RD WH RD GN/YL WH/BK BK GN/YL Part No. 38139 SW13 2 1 RD TO PLATFORM 1 QD4 RD WH BK 7 WH 6 GN/YL 4 BL 3 QUICK DISCONNECT A POWER UNIT OR OR WH BK 2 RD 1 TO MOTOR OR QD3 STRAIN RELIEF GN/YL POWER SUPPLY AC WH RD BL D5 WH WH BK QD7 SW14 WH BASE *N17 POWER TO PLATFORM GFCI RECEPTACLE RD OR GN/YL BK UP DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. EN4 6 BK BK BK PLATFORM UP/DOWN EN2 GROUND CONTROL BOX W5 GROUND STUD WH BK SW11 GND SW8 CONTROL ACTIVATE 5 GN/YL RD GND GROUND STUD GN/YL PLATFORM CONTROL BOX WT EN1 OR N 8 Y7 N.C. PLATFORM DOWN Genie AWP Super Series and Genie IWP Super Series 7-5 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC Models (from serial number 3896-101 to 3896-300) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD1 = Battery quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 4 pole 8 pin W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN GND KS1 L M5 N.C. N.O. P QD SW U W Y WIRE COLOR LEGEND Color BL BK GN/YL OR RD WH WH/BK Description Blue Black Green/Yellow Orange Red White White/Black Note: Use these 2 legends for the schematic on the opposing page. First Edition • Second Printing Section 7 • Schematics Electrical Schematic AWP Super Series DC Models (from serial number 3896-301 to 3896-430) M L K J I H G F E D C B A 1 BK KS1 GROUND/ PLATFORM RD RD RD BK BK BK N.O. RD 1 P1 + EMERGENCY STOP RD 16.0V DC INPUT 1 2 3 L5 L14 L12 - BK N.C. BK L15 L13 B4 8 AA BATTERIES SW12 L7 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN N.O. WH W3 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 14 FRONT LEFT 2 LEVELING INDICATORS RD BK LEVELING INDICATOR INPUTS 5 LED 13 REAR RIGHT 6 LED 15 REAR LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 UP SIGNAL OUTPUT 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 L6 LOW BATTERY INDICATOR FOR AUXILIARY LOWERING U10 WH 4 LED 12 FRONT RIGHT POWER INDICATOR 2 3 OR BL RD BK RD RD GN/YL 3 RD OR W4 PC BOARD RD WH 4 P2 EMERGENCY STOP RD WH N.C. BL WH WH GN/YL BK GROUND STUD B2 BATTERY 12V DC - BATTERY CONNECTOR RD RD BK BK FRONT LEFT INTERLOCK BK BK W6 7 TO BASE MOTOR CONTACTOR 1 2 3 4 5 6 7 BK M5 MOTOR 7 REAR RIGHT INTERLOCK + OR 6 SW16 BK 7 5 REAR LEFT INTERLOCK 6 4 SW15 4 3 FRONT RIGHT INTERLOCK 3 RD 2 QUICK DISCONNECT B WH Y30 N.O. DUMP VALVE RD RD BL RD OR RD WH RD GN/YL WH/BK BK GN/YL Part No. 38139 SW13 2 1 RD TO PLATFORM 1 QD4 BK WH RD 7 BK 6 WH 4 OR 3 QUICK DISCONNECT A POWER UNIT GN/YL BK OR WH RD 2 OR 1 TO MOTOR GN/YL QD3 WH RD POWER SUPPLY AC WH BK WH BL D5 STRAIN RELIEF SW14 QD7 BL WH BASE *N17 POWER TO PLATFORM GFCI RECEPTACLE RD OR GN/YL BK DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. EN4 6 BK BK BK PLATFORM UP/DOWN TERMINAL STRIP UP GN/YL SW11 EN2 GROUND CONTROL BOX W5 GROUND STUD WT BK GN/YL GND SW8 CONTROL ACTIVATE 5 GN/YL RD GND GROUND STUD WH EN1 PLATFORM CONTROL BOX OR N 8 Y7 N.C. PLATFORM DOWN Genie AWP Super Series and Genie IWP Super Series 7-6 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC Models (from serial number 3896-301 to 3896-430) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD1 = Battery quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 4 pole 8 pin W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN GND KS1 L M5 N.C. N.O. P QD SW U W Y WIRE COLOR LEGEND Color BL BK GN/YL OR RD WH WH/BK Description Blue Black Green/Yellow Orange Red White White/Black Note: Use these 2 legends for the schematic on the opposing page. First Edition • Second Printing Section 7 • Schematics Electrical Schematic AWP Super Series DC Models (from serial number 3896-431 to AWP07-54898) M L K J I H G F E D C B A 1 BK KS1 GROUND/ PLATFORM RD RD RD BK BK BK N.O. 1 + P1 RD 16.0V DC INPUT 1 2 3 L5 - RD BK W3 CENTER TAP INPUT 12V DC POWER INPUT 16.0V DC INPUT NEGATIVE 12V DC AUX. INPUT POSITIVE 12V DC AUX. INPUT LED 14 FRONT LEFT 2 LEVELING INDICATORS EMERGENCY STOP L14 L12 BK BK B4 N.C. LEVELING INDICATOR INPUTS 5 6 LED 15 REAR LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A LOW BATTERY L7 SW12 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN N.O. GROUND 10 UP SIGNAL OUTPUT 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 U10 WH 4 LED 13 REAR RIGHT L6 2 3 LED 12 FRONT RIGHT POWER INDICATOR INDICATOR FOR L15 L13 AUXILIARY LOWERING 8 AA BATTERIES OR BL RD BK RD GN/YL 3 RD OR W4 PC BOARD RD 4 RD BL BN P2 EMERGENCY STOP RD WH N.C. UP + OR BL WH WH GN/YL BK GROUND STUD B2 BATTERY 12V DC - BATTERY CONNECTOR RD RD BK BK FRONT LEFT INTERLOCK BK BK BK W6 7 TERMINAL STRIP TO BASE MOTOR CONTACTOR 1 2 3 4 5 6 7 BK M5 MOTOR 7 REAR RIGHT INTERLOCK QD1 6 SW16 BK 7 5 REAR LEFT INTERLOCK 6 4 SW15 4 3 FRONT RIGHT INTERLOCK 3 RD 2 QUICK DISCONNECT B WH Y30 N.O. DUMP VALVE RD RD BL RD OR RD WH RD GN/YL YL BK GN/YL Part No. 38139 SW13 2 1 RD TO PLATFORM 1 QD4 RD WH BK 7 GN/YL 6 BN 4 BL 3 QUICK DISCONNECT A POWER UNIT OR OR WH BK 2 RD 1 TO MOTOR OR QD3 STRAIN RELIEF GN/YL POWER SUPPLY AC BL RD OR D5 WH WH BK QD7 SW14 WH BK BASE *N17 EN4 6 DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. POWER TO PLATFORM GFCI RECEPTACLE RD OR GN/YL BK TERMINAL STRIP BK BK GN/YL PLATFORM UP/DOWN WH EN2 GROUND CONTROL BOX W5 GROUND STUD CONTROL ACTIVATE SW11 GN/YL GND SW8 BK 5 GN/YL RD GND GROUND STUD WH EN1 PLATFORM CONTROL BOX BL N 8 Y7 N.C. PLATFORM DOWN Genie AWP Super Series and Genie IWP Super Series 7-7 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC Models (from serial number 3896-4311 to AWP07-54898) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Fuse — 175 Amp Warning light Ground Descent alarm Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Note with description *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units without plug: WH and BK wires replace BL and BN wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD1 = Battery quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U 9 = Battery charger U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 5 pole 10 pin W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN F11 FB2 GND H4 KS1 L M5 *N N.C. N.O. P QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC Models with Standard Base (after serial number AWP07-54898) N M L K J I H G F E D C RD/BLK KS1 PLATFORM MODE KEY SWITCH P2 WH 1 RD 1 RD P1 EMERGENCY STOP SW8 BK RD BK BK 1 CENTER TAP INPUT 12V DC POWER INPUT 16.0V DC INPUT NEGATIVE 12V DC AUX. INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT RIGHT 2 2 3 LEVELING INDICATORS BK B4 N.C. 8 AA BATTERIES WH L13 L15 L12 L14 L5 L6 LOW BATTERY INDICATOR FOR AUXILIARY LOWERING SW12 DOWN 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 UP SIGNAL INPUT 13 OR RD BL RD BK BK SW15 SW16 SW13 SW14 W6 BL Y7 TERMINAL STRIP RD BK 1 2 N.C. PLATFORM DOWN YL RD/BLK GN/YL WHT 3 RD STANDARD BASE OR W4 BN 4 BK WH WH GND GROUND STUD GND GN/YL W5 6 7 7 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH BK WH GN/YL BN GN/YL 5 BK 6 RD RD BN 7 BK OR GN/YL 4 5 6 RD BL OR WHT 1 2 3 4 5 GN/YL BL BL BL GROUND STUD 1 2 3 BK WH WH *N27 QD3 GROUND CONTROL BOX TERMINAL STRIP UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL(1) AND BN(7) WIRES. QD4 EN2 BK WH GROUND STUD RD EN4 POWER TO PLATFORM GFCI RECEPTACLE RD RD BL WH BK BL OR BN RD BK 7 U10 RD FRONT RIGHT INTERLOCK FRONT LEFT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK N.O. *N17 GN/YL LED 12 FRONT LEFT PC BOARD AUXILIARY DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. 6 12 RD BK OR 5 LED 14 REAR LEFT 11 RD WH 4 UP SIGNAL OUTPUT WH BK 3 UP SIGNAL OUTPUT (DELAYED) A BK LED 15 REAR RIGHT L7 DC MODEL: LOW BATTERY INDICATOR POWER INDICATOR UP LEVELING INDICATOR INPUTS OR BK RD W3 16.0V DC INPUT WH PLATFORM UP/DOWN BK N.C. CONTROL ACTIVATE SW11 BASE MODE RD BN EMERGENCY STOP 2 + PLATFORM CONTROL BOX B1 B WH BK 3 RD 4 BK BK EN1 WH BK RD/BLK RD B STRAIN RELIEF STRAIN RELIEF TO PLUG TO MOTOR D5 POWER SUPPLY AC WH GN/YL H4 7 DESCENT ALARM POWER UNIT OR RD WH FB2 BK RD WARNING LIGHT OPTIONAL WARNING LIGHT AND DESCENT ALARM RD BK B2 U9 BATTERY CHARGER AC INPUT + - RD BATTERY 12V DC + QD1 RD BK BK - RD BK MOTOR CONTACTOR 8 M5 F11 175 AMP FUSE NON U.S. PLUGS MOTOR WH Y30 Part No. 38139 N.O. DUMP VALVE ES0070_G Genie AWP Super Series and Genie IWP Super Series 7-8 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC Models with Standard Base (after serial number AWP07-54898) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Fuse — 175 Amp Warning light Ground Descent alarm Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Note with description *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units without plug: WH and BK wires replace BL and BN wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD1 = Battery quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U 9 = Battery charger U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 5 pole 10 pin W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN F11 FB2 GND H4 KS1 L M5 *N N.C. N.O. P QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black White Yellow Note: Use these 2 legends for the schematic on the opposing page. First Edition • Second Printing Section 7 • Schematics Electrical Schematic AWP Super Series DC Models with Narrow Base (after serial number AWP07-54898) N M L K J I H G F E D C RD/BLK KS1 PLATFORM MODE KEY SWITCH P2 1 RD 1 RD P1 EMERGENCY STOP SW8 BK RD BK BK 1 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 12 FRONT LEFT 2 2 3 LEVELING INDICATORS BK B4 N.C. 8 AA BATTERIES WH L12 L13 L14 L15 L5 L6 SW12 DOWN 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 UP SIGNAL INPUT 13 U10 RD RD RD BK BK SW15 SW16 SW14 SW13 W6 BL Y7 TERMINAL STRIP RD BK 1 2 N.C. PLATFORM DOWN YL RD/BLK GN/YL WHT 3 RD NARROW BASE OR W4 BN 4 BK WH WH RD GND GROUND STUD GND GN/YL W5 6 7 RD BK GN/YL 4 5 OR 1 2 3 BL 7 WHT 6 BK 7 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH WH GN/YL BN GN/YL RD RD BN GN/YL OR BL BL BL GROUND STUD 4 5 5 BK 6 STRAIN RELIEF STRAIN RELIEF TO PLUG 1 2 3 RD WH WH *N27 QD3 GROUND CONTROL BOX TERMINAL STRIP UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL(1) AND BN(7) WIRES. QD4 EN2 BK RD WH GROUND STUD POWER TO PLATFORM GFCI RECEPTACLE OR RD BL WH BK BL OR BN EN4 BK 7 12 BL FRONT LEFT INTERLOCK FRONT RIGHT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK N.O. *N17 GN/YL LED 14 REAR LEFT PC BOARD AUXILIARY DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. 6 11 RD BK OR 5 UP SIGNAL OUTPUT OR WH 4 UP SIGNAL OUTPUT (DELAYED) RD BK 3 LED 15 REAR RIGHT L7 DC MODEL: LOW BATTERY INDICATOR WH BK LED 13 FRONT RIGHT LOW BATTERY INDICATOR FOR AUXILIARY LOWERING POWER INDICATOR UP LEVELING INDICATOR INPUTS WH BK RD W3 16.0V DC INPUT A BK PLATFORM UP/DOWN BK WH N.C. CONTROL ACTIVATE SW11 BASE MODE RD BN EMERGENCY STOP 2 + PLATFORM CONTROL BOX B1 B WH BK 3 RD 4 BK BK EN1 WH BK RD/BLK RD B TO MOTOR D5 POWER SUPPLY AC WH GN/YL H4 7 DESCENT ALARM POWER UNIT OR RD WH FB2 BK RD WARNING LIGHT OPTIONAL WARNING LIGHT AND DESCENT ALARM B2 U9 BATTERY CHARGER AC INPUT + - RD BATTERY 12V DC + QD1 RD BK BK - RD BK MOTOR CONTACTOR RD BK 8 M5 F11 MOTOR 175 AMP FUSE NON U.S. PLUGS Part No. 38139 WH Y30 N.O. DUMP VALVE ES0070_G Genie AWP Super Series and Genie IWP Super Series 7-9 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC Models with Narrow Base (after serial number AWP07-54898) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Radio noise reduction Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Fuse F1 = 175A fuse Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD1 = Battery quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 4 pole 8 pin W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve C3 D5 EN F GND KS1 L M5 KS1 M5 *N17 N.C. N.O P QD SW U W Y Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC CE Models (from serial number 3896-432 to AWP07-54898) M L K J I H G F E D C B A 1 KS1 PLATFORM N.O. RD BK RD RD BK BK BK BK BK RD KS1 GROUND N.O. 1 RD RD RD 1 2 L14 L12 9 12V DC OUTPUT 9A LOW BATTERY B4 L7 8 AA BATTERIES SW12 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN N.O. RD BN 12V DC OUTPUT FOR L15 L13 INDICATOR AUXILIARY LOWERING BK OR BL 6 RD 7 BK 8 GROUND 10 UP SIGNAL OUTPUT 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 U10 WH 4 5 L6 2 3 LEVELING LED 12 FRONT RIGHT INDICATOR LED 13 REAR RIGHT INPUTS LED 15 REAR LEFT POWER INDICATOR 12V DC OUTPUT - BK RD WH 3 RD OR W4 PC BOARD 4 BL EN1 16.0V DC INPUT 3 L5 RD BK W3 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 14 FRONT LEFT 2 LEVELING INDICATORS + P1 EMERGENCY STOP N.C. PLATFORM CONTROL BOX EN3 REMOTE BOX P2 GND RD WH WH N.C. N.O. 5 GN/YL GROUND STUD GND GROUND CONTROL BOX W5 GROUND STUD RD OR WH BK TERMINAL STRIP WH SW11 EN2 RD EMERGENCY STOP WH SW8 CONTROL ACTIVATE 6 PLATFORM UP/DOWN 6 7 + OR BL EN4 POWER TO PLATFORM GFCI RECEPTACLE BK GROUND STUD GN/YL BK B2 BATTERY 12V DC RD RD BK BK - + WH WH GN/YL B2 BATTERY 12V DC QD1 BATTERY CONNECTOR - QD1 BATTERY CONNECTOR RD RD BK BK BK RD F1 175A FUSE FRONT LEFT INTERLOCK BK BK W6 BK 7 7 TERMINAL STRIP QUICK DISCONNECT B TO BASE 1 2 3 4 5 6 7 BK M5 MOTOR 6 REAR RIGHT INTERLOCK 4 5 SW16 3 4 REAR LEFT INTERLOCK 2 3 SW15 1 RD MOTOR CONTACTOR 2 FRONT RIGHT INTERLOCK RD 1 WH Y30 N.O. DUMP VALVE RD RD WH RD BL RD OR RD YL GN/YL Part No. 38139 SW13 TO PLATFORM QD4 BK WH RD RD 7 WH 6 QUICK DISCONNECT A BN 4 POWER UNIT OR BL 3 STRAIN RELIEF TO MOTOR FERRITE GAURD OR BK 2 RD 1 OR QD3 GN/YL POWER SUPPLY AC BL RD OR D5 WH WH BK QD7 C3 WH *N17 NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. SW14 BASE WH BK GN/YL DOWN BK BK UP BL BK N 8 Y7 N.C. PLATFORM DOWN Genie AWP Super Series and Genie IWP Super Series 7 - 10 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC CE Models (from serial number 3896-432 to AWP07-54898) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Fuse — 175 Amp Warning light Ground Descent alarm Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Note with description *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units without plug: WH and BK wires replace BL and BN wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD1 = Battery quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U 9 = Battery charger U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 5 pole 10 pin W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN F11 FB2 GND H4 KS1 L M5 *N N.C. N.O. P QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC CE Models with Standard Base (after serial number AWP07-54898) N M L K J I H G F E D C RD/BLK KS1 PLATFORM MODE KEY SWITCH P2 WH 1 RD 1 RD P1 EMERGENCY STOP SW8 BK RD BK BK 1 CENTER TAP INPUT 12V DC POWER INPUT 16.0V DC INPUT NEGATIVE 12V DC AUX. INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT RIGHT 2 2 3 LEVELING INDICATORS BK B4 N.C. 8 AA BATTERIES WH L13 L15 L12 L14 L5 L6 LOW BATTERY INDICATOR FOR AUXILIARY LOWERING SW12 DOWN 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 UP SIGNAL INPUT 13 OR RD BL RD BK BK SW15 SW16 SW13 SW14 W6 BL Y7 TERMINAL STRIP RD BK 1 2 N.C. PLATFORM DOWN YL RD/BLK GN/YL WHT 3 RD STANDARD BASE OR W4 BN 4 BK WH WH GND GROUND STUD GND GN/YL W5 6 7 7 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH BK WH GN/YL BN GN/YL 5 BK 6 RD RD BN 7 BK OR GN/YL 4 5 6 RD BL OR WHT 1 2 3 4 5 GN/YL BL BL BL GROUND STUD 1 2 3 BK WH WH *N27 QD3 GROUND CONTROL BOX TERMINAL STRIP UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL(1) AND BN(7) WIRES. QD4 EN2 BK WH GROUND STUD RD EN4 POWER TO PLATFORM GFCI RECEPTACLE RD RD BL WH BK BL OR BN RD BK 7 U10 RD FRONT RIGHT INTERLOCK FRONT LEFT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK N.O. *N17 GN/YL LED 12 FRONT LEFT PC BOARD AUXILIARY DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. 6 12 RD BK OR 5 LED 14 REAR LEFT 11 RD WH 4 UP SIGNAL OUTPUT WH BK 3 UP SIGNAL OUTPUT (DELAYED) A BK LED 15 REAR RIGHT L7 DC MODEL: LOW BATTERY INDICATOR POWER INDICATOR UP LEVELING INDICATOR INPUTS OR BK RD W3 16.0V DC INPUT WH PLATFORM UP/DOWN BK N.C. CONTROL ACTIVATE SW11 BASE MODE RD BN EMERGENCY STOP 2 + PLATFORM CONTROL BOX B1 B WH BK 3 RD 4 BK BK EN1 WH BK RD/BLK RD B STRAIN RELIEF STRAIN RELIEF TO PLUG TO MOTOR D5 POWER SUPPLY AC WH GN/YL H4 7 DESCENT ALARM POWER UNIT OR RD WH FB2 BK RD WARNING LIGHT OPTIONAL WARNING LIGHT AND DESCENT ALARM RD BK B2 U9 BATTERY CHARGER AC INPUT + - RD BATTERY 12V DC + QD1 RD BK BK - RD BK MOTOR CONTACTOR 8 M5 F11 MOTOR 175 AMP FUSE NON U.S. PLUGS Part No. 38139 WH Y30 N.O. DUMP VALVE ES0070_G Genie AWP Super Series and Genie IWP Super Series 7 - 11 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC CE Models with Standard Base (after serial number AWP07-54898) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Fuse — 175 Amp Warning light Ground Descent alarm Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Note with description *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units without plug: WH and BK wires replace BL and BN wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD1 = Battery quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U 9 = Battery charger U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 5 pole 10 pin W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN F11 FB2 GND H4 KS1 L M5 *N N.C. N.O. P QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black White Yellow Note: Use these 2 legends for the schematic on the opposing page. First Edition • Second Printing Section 7 • Schematics Electrical Schematic AWP Super Series DC CE Models with Narrow Base (after serial number AWP07-54898) N M L K J I H G F E D C RD/BLK KS1 PLATFORM MODE KEY SWITCH P2 1 RD 1 RD P1 EMERGENCY STOP SW8 BK RD BK BK 1 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 12 FRONT LEFT 2 2 3 LEVELING INDICATORS BK B4 N.C. 8 AA BATTERIES WH L12 L13 L14 L15 L5 L6 SW12 DOWN 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 UP SIGNAL INPUT 13 U10 RD RD RD BK BK SW15 SW16 SW14 SW13 W6 BL Y7 TERMINAL STRIP RD BK 1 2 N.C. PLATFORM DOWN YL RD/BLK GN/YL WHT 3 RD NARROW BASE OR W4 BN 4 BK WH WH RD GND GROUND STUD GND GN/YL W5 6 7 RD BK GN/YL 4 5 OR 1 2 3 BL 7 WHT 6 BK 7 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH WH GN/YL BN GN/YL RD RD BN GN/YL OR BL BL BL GROUND STUD 4 5 5 BK 6 STRAIN RELIEF STRAIN RELIEF TO PLUG 1 2 3 RD WH WH *N27 QD3 GROUND CONTROL BOX TERMINAL STRIP UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL(1) AND BN(7) WIRES. QD4 EN2 BK RD WH GROUND STUD POWER TO PLATFORM GFCI RECEPTACLE OR RD BL WH BK BL OR BN EN4 BK 7 12 BL FRONT LEFT INTERLOCK FRONT RIGHT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK N.O. *N17 GN/YL LED 14 REAR LEFT PC BOARD AUXILIARY DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. 6 11 RD BK OR 5 UP SIGNAL OUTPUT OR WH 4 UP SIGNAL OUTPUT (DELAYED) RD BK 3 LED 15 REAR RIGHT L7 DC MODEL: LOW BATTERY INDICATOR WH BK LED 13 FRONT RIGHT LOW BATTERY INDICATOR FOR AUXILIARY LOWERING POWER INDICATOR UP LEVELING INDICATOR INPUTS WH BK RD W3 16.0V DC INPUT A BK PLATFORM UP/DOWN BK WH N.C. CONTROL ACTIVATE SW11 BASE MODE RD BN EMERGENCY STOP 2 + PLATFORM CONTROL BOX B1 B WH BK 3 RD 4 BK BK EN1 WH BK RD/BLK RD B TO MOTOR D5 POWER SUPPLY AC WH GN/YL H4 7 DESCENT ALARM POWER UNIT OR RD WH FB2 BK RD WARNING LIGHT OPTIONAL WARNING LIGHT AND DESCENT ALARM B2 U9 BATTERY CHARGER AC INPUT + - RD BATTERY 12V DC + QD1 RD BK BK - RD BK MOTOR CONTACTOR RD BK 8 M5 F11 MOTOR 175 AMP FUSE NON U.S. PLUGS Part No. 38139 WH Y30 N.O. DUMP VALVE ES0070_G Genie AWP Super Series and Genie IWP Super Series 7 - 12 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC CE Models with Narrow Base (after serial number AWP07-54898) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Fuse F1 = 175A fuse Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD1 = Battery quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 4 pole 8 pin W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN F GND KS1 L M5 KS1 M5 *N17 N.C. N.O P QD SW U W Y WIRE COLOR LEGEND Color BL BK GN/YL OR RD WH Description Blue Black Green/Yellow Orange Red White Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC TUV Models (after serial number 3896-430) M L K J I H G F E D C B A 1 KS1 GROUND/ PLATFORM BK RD RD RD BK BK BK N.O. 1 + P1 RD 16.0V DC INPUT 1 2 L5 L14 L12 BK BK B4 N.C. 5 6 LED 15 REAR LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A L6 L7 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN N.O. RD GROUND 10 UP SIGNAL OUTPUT 11 UP SIGNAL OUTPUT (DELAYED) 12 U10 UP SIGNAL INPUT WH 4 LED 13 REAR RIGHT POWER INDICATOR 2 3 LED 12 FRONT RIGHT LOW BATTERY SW12 OR BL RD BK RD 3 WH RD OR 13 W4 PC BOARD 4 RD BL LEVELING INDICATOR INPUTS FOR L15 L13 INDICATOR AUXILIARY LOWERING 8 AA BATTERIES BL 3 - RD BK W3 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 14 FRONT LEFT 2 LEVELING INDICATORS EMERGENCY STOP P2 EMERGENCY STOP RD WH N.C. GND BK 7 + OR QD1 BL WH WH BK GROUND STUD B2 BATTERY 12V DC - BATTERY CONNECTOR RD RD BK BK RD F1 175A FUSE FRONT LEFT INTERLOCK BK BK W6 BK BK 7 7 TERMINAL STRIP QUICK DISCONNECT B TO BASE MOTOR CONTACTOR 1 2 3 4 5 6 7 BK M5 MOTOR 6 REAR RIGHT INTERLOCK 6 5 SW16 4 4 REAR LEFT INTERLOCK 3 3 SW15 2 2 FRONT RIGHT INTERLOCK 1 1 WH Y30 N.O. DUMP VALVE RD RD WH RD BL RD OR RD GN/YL BL BK WH Part No. 38139 SW13 TO PLATFORM RD QD4 RD WH RD BL 7 WH 6 BL 4 QUICK DISCONNECT A OR 3 POWER UNIT OR WH 2 BK 1 RD WH QD3 OR POWER SUPPLY AC STRAIN RELIEF TO MOTOR GN/YL RD OR D5 BL WH BK QD7 SW14 WH BASE RD GN/YL RD UP *N17 POWER TO PLATFORM GFCI RECEPTACLE 6 DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. EN4 OR BK TERMINAL STRIP BK BK BK PLATFORM UP/DOWN GN/YL SW11 WH GROUND CONTROL BOX W5 GROUND STUD CONTROL ACTIVATE EN2 RD WH GND SW8 BK 5 GN/YL GROUND STUD WH PLATFORM CONTROL BOX WH EN1 BL N 8 Y7 N.C. PLATFORM DOWN Genie AWP Super Series and Genie IWP Super Series 7 - 13 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series DC TUV Models (after serial number 3896-430) ABBREVIATION LEGEND Item Description B1 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Ground Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board U12 = Thermal device Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve GND KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN GN/YL OR RD RD/YL WH WH/BK YL Description Blue Black Brown Green Green/Yellow Orange Red Red/Yellow White White/Black Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models (from serial number 3896-103 to 3896-303) M L K J I H G F E D C B A 1 KS1 + BK 1 SW12 2 3 W3 16.0V DC INPUT 1 CENTER TAP INPUT 2 16.0V DC INPUT 3 LED 14 FRONT LEFT 4 LED 12 FRONT RIGHT 5 LED 13 REAR RIGHT 6 LED 15 REAR LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 UP SIGNAL OUTPUT 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT POSITIVE 12V DC AUX. INPUT - LEVELING INDICATORS B1 AUXILIARY DOWN BK 8 AA BATTERIES L14 L12 RD WH L15 L13 L7 DC MODEL: LOW BATTERY INDICATOR LEVELING INDICATOR INPUTS L5 POWER INDICATOR L6 LOW BATTERY INDICATOR FOR AUXILIARY LOWERING U10 PC BOARD WH RD RD/YL BN RD BL 2 WH OR BL RD BK RD RD 3 GN/YL RD BK OR W4 RD WH WH BK WIRE DISCONNECTED PR4 BK CB4 4 *N9 220V AC TERMINAL STRIP DETAIL 15A CIRCUIT BREAKER 110V AC MODELS BK WH GN/YL GROUND STUD GN/YL 1 3 5 2 4 8 M5 110V AC MOTOR DETAIL GND 4 M5 220V AC MOTOR DETAIL 8 WH BN WH WT BK REAR LEFT INTERLOCK REAR RIGHT INTERLOCK SW15 SW16 W6 FRONT RIGHT INTERLOCK 7 SW14 6 FRONT LEFT INTERLOCK BK 5 BK WH GN/YL 4 RD BL 3 GND BK 1 2 3 4 5 6 7 BK RD RD BL RD OR RD WH RD WH/BK GN/YL Part No. 38139 SW13 GN/YL BK *N10 MOTOR 2 QUICK DISCONNECT B 7 TO BASE N.O. DUMP VALVE J-BOX OR WH EN6 1 *N8 MOTOR Y30 1 BK GN/YL J-BOX QD4 GROUND SCREW BK EN5 N.O. DUMP VALVE GN/YL Y30 GROUND SCREW WH 7 BK 6 BK 4 WH BL 3 STRAIN RELIEF GN/YL OR 2 QD7 TO MOTOR TO PLATFORM 1 GROUND STUD GN/YL 7 BK 6 WH 4 QUICK DISCONNECT A GROUND CONTROL BOX GND GN/YL BK 3 GN/YL 2 RD 1 WH QD3 OR POWER SUPPLY AC WH BK RD WH BL D5 RD WH BASE EN2 *N17 NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. GN/YL BN WH WH BK UP DOWN 6 GROUND STUD WH BK BK PLATFORM UP/DOWN WH GN/YL BK TERMINAL STRIP *N7 110V AC TERMINAL STRIP DETAIL BK W5 GN/YL WT GN/YL BL BK WH BK GN/YL SW11 5 TERMINAL STRIP BK N.C. WH GROUND STUD RD BK WH SW8 BK BL W5 GND EMERGENCY STOP GN/YL P2 CONTROL BK ACTIVATE 110V AC / 220V AC WH BN BK EN4 BK BK PLATFORM CONTROL BOX POWER TO PLATFORM GFCI RECEPTACLE U12 U9 8A CIRCUIT BREAKER 220V AC MODELS EN1 YL TRANSFORMER WH BK N.O. WH YL BK WH BK N.C. TRANSFORMER RD WH YL GROUND/ PLATFORM WH EMERGENCY STOP U12 THERMAL DEVICE U9 BL P1 OR N 8 Y7 N.C. PLATFORM DOWN Genie AWP Super Series and Genie IWP Super Series 7 - 14 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models (from serial number 3896-103 to 3896-303) ABBREVIATION LEGEND Item Description B1 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Ground Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board U12 = Thermal device Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve GND KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN GN/YL OR RD RD/YL WH WH/BK YL Description Blue Black Brown Green Green/Yellow Orange Red Red/Yellow White White/Black Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models (from serial number 3896-304 to 3896-450) M L K J I H G F E D C B A 1 KS1 P1 - 1 CENTER TAP INPUT 2 16.0V DC INPUT 3 LED 14 FRONT LEFT 4 LED 12 FRONT RIGHT 5 LED 13 REAR RIGHT 6 LED 15 REAR LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 UP SIGNAL OUTPUT 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 L14 L12 POWER INDICATOR L15 L13 LOW BATTERY INDICATOR FOR AUXILIARY LOWERING RD L7 WH DC MODEL: LOW BATTERY INDICATOR L6 U10 PC BOARD BN RD BL 2 WH OR BL RD BK RD RD 3 GN/YL RD BK OR W4 RD WH BK WIRE DISCONNECTED PR4 BK CB4 4 *N9 220V AC TERMINAL STRIP DETAIL 15A CIRCUIT BREAKER 110V AC MODELS BK WH GN/YL GROUND STUD GN/YL 1 3 5 2 4 8 M5 110V AC MOTOR DETAIL GND WH BN WH WT BK FRONT RIGHT INTERLOCK REAR LEFT INTERLOCK REAR RIGHT INTERLOCK SW15 SW16 W6 SW14 7 FRONT LEFT INTERLOCK 6 BK 5 BK BK 4 WH GN/YL 3 RD BL OR WH BK WH Y30 N.O. DUMP VALVE J-BOX 4 2 QUICK DISCONNECT B 7 TO BASE EN6 1 *N8 MOTOR 1 M5 *N10 MOTOR 220V AC MOTOR DETAIL 8 GND BK 1 2 3 4 5 6 7 BK RD RD BL RD OR RD WH RD WH/BK GN/YL Part No. 38139 SW13 N.O. DUMP VALVE J-BOX BK EN5 Y30 QD4 GROUND SCREW GN/YL GROUND SCREW WH 7 GN/YL 6 GN/YL 4 BK BL 3 STRAIN RELIEF WH OR 2 QD7 TO MOTOR TO PLATFORM 1 GROUND STUD BK 7 BK 6 GROUND CONTROL BOX GND GN/YL 4 QUICK DISCONNECT A WH BK 3 GN/YL 2 RD 1 WH QD3 OR POWER SUPPLY AC WH BK RD WH BL D5 RD WH BASE EN2 *N17 NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. GN/YL GN/YL BN WH WH BK UP DOWN 6 GROUND STUD WH BK BK PLATFORM UP/DOWN WH GN/YL BK TERMINAL STRIP *N7 110V AC TERMINAL STRIP DETAIL BK W5 GN/YL WT GN/YL BL BK WH BK GN/YL SW11 5 TERMINAL STRIP BK N.C. WH GROUND STUD RD BK WH SW8 BK BL W5 GND GN/YL P2 EMERGENCY STOP CONTROL BK ACTIVATE 110V AC / 220V AC WH BN BK EN4 BK BK PLATFORM CONTROL BOX POWER TO PLATFORM GFCI RECEPTACLE U12 U9 8A CIRCUIT BREAKER 220V AC MODELS EN1 YL TRANSFORMER WH WH WH AUXILIARY DOWN L5 RD/YL WH 8 AA BATTERIES LEVELING INDICATOR INPUTS WH RD 16.0V DC INPUT WH + B1 SW12 WH 3 LEVELING INDICATORS YL N.C. 2 W3 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT POSITIVE 12V DC AUX. INPUT RD N.C. BK BK 1 EMERGENCY STOP BK YL BK BK N.O. TRANSFORMER RD RD N.O. BK BL BK U12 THERMAL DEVICE U9 GROUND/ PLATFORM OR N 8 Y7 N.C. PLATFORM DOWN Genie AWP Super Series and Genie IWP Super Series 7 - 15 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models (from serial number 3896-304 to 3896-450) ABBREVIATION LEGEND Item Description B1 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Ground Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board U12 = Thermal device Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve GND KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN GN/YL OR RD RD/YL WH WH/BK YL Description Blue Black Brown Green Green/Yellow Orange Red Red/Yellow White White/Black Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models (from serial number 3896-451 to AWP07-54898) N M L K J I H G F E D C B A 1 2 3 4 5 6 7 8 Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 16 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models (from serial number 3896-451 to AWP07-54898) ABBREVIATION LEGEND Item Description B4 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Warning light Ground Descent alarm Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units with out plug: WH and BK wires replace BL and BN wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 8 pole 16 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve FB2 GND H4 KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK RD/YL WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models with Standard Base (from serial number AWP07-54899 to AWP07-57594) N M L K J I H G F E D C B A RD/BLK 1 KS1 PLATFORM MODE KEY SWITCH P2 BN BK 1 P1 BK 2 L6 LOW BATTERY INDICATOR FOR AUXILIARY LOWERING N.C. MODEL: L12 L14 DC LOW BATTERY INDICATOR L5 RD AUXILIARY DOWN RD RD RD OR RD WH BL RD OR BK RD/YL RD WH 5 6 LED 12 FRONT LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A BK RD GROUND 10 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 BK BK RD/BLK BK WH BK BK N.C. PLATFORM DOWN 2 3 YL OR GN/YL W4 4 WH RD OR WH PR4 BK EN4 8A CIRCUIT BREAKER 220V AC MODELS 15A CIRCUIT BREAKER 110V AC MODELS CB4 POWER TO PLATFORM GFCI RECEPTACLE QD4 WH WH BL WH 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH 6 WH GN/YL BN BK 7 BK WH GN/YL H4 GND GN/YL WH GN/YL BK WH GROUND STUD 7 STRAIN RELIEF DESCENT ALARM TO MOTOR RD BL OR WH YL 1 3 BL *N8 MOTOR 110V AC MOTOR DETAIL 2 4 GND OR YL EN6 WH 1 3 BK J-BOX WH M5 N.O. DUMP VALVE BK J-BOX GROUND SCREW Y30 GN/YL OPTIONAL WARNING LIGHT AND DESCENT ALARM EN5 WH WARNING LIGHT BK GROUND SCREW BK GN/YL FB2 WH BN BL D5 POWER SUPPLY AC 5 BK GROUND STUD TO PLUG BK 7 STRAIN RELIEF WH 6 110V AC TERMINAL STRIP DETAIL TERMINAL STRIP WH BN RD RD BK 7 BK OR GN/YL 4 5 6 RD BL OR WHT 1 2 3 4 5 GN/YL BL WH GN/YL GROUND STUD 1 2 3 *N7 W5 UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL AND BN WIRES. WH WH *N27 WH BK BK BL WH BL OR Y7 TERMINAL STRIP OR FRONT RIGHT INTERLOCK FRONT LEFT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK STANDARD BASE GND QD3 SW15 SW16 SW13 SW14 W6 WHT OR BL BK BL BN BN GROUND STUD BK WH YL BK BN BL N.O. *N17 GN/YL 4 LED 14 REAR LEFT PC BOARD RD 3 UP SIGNAL OUTPUT U10 POWER INDICATOR UP SW12 TRANSFORMER RD LED 15 REAR RIGHT L7 WH DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. LEVELING INDICATOR INPUTS BK BK 1 L13 L15 8 AA BATTERIES YL BK B4 RD RD RD 16.0V DC INPUT 3 LEVELING INDICATORS + EMERGENCY STOP W3 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT RIGHT 2 FOR 240 V OPERATION JUMPER BROWN TO WHITE THROUGH TERMINAL STRIP AND LEAVE BLACK UNCONNECTED AS SHOWN U9 WH 1 N.C. SW8 PLATFORM UP/DOWN 2 BASE MODE RD CONTROL ACTIVATE SW11 BK B GROUND CONTROL BOX BK RD PLATFORM CONTROL BOX B1 EMERGENCY STOP WH EN2 3 RD 4 BK BK EN1 WH - RD/BLK RD M5 Y30 N.O. DUMP VALVE 8 *N10 MOTOR 220 V AC MOTOR DETAIL 2 4 GND ES0071_F Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 17 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models with Standard Base (from serial number AWP07-54899 to AWP07-57594) ABBREVIATION LEGEND Item Description B4 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Warning light Ground Descent alarm Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units with out plug: WH and BK wires replace BL and BN wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 8 pole 16 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve FB2 GND H4 KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK RD/YL WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. First Edition • Second Printing Section 7 • Schematics Electrical Schematic AWP Super Series AC Models with Narrow Base (from serial number AWP07-54899 to AWP07-57594) N M L K J I H G F E D C B A RD/BLK 1 KS1 PLATFORM MODE KEY SWITCH P2 RD 1 P1 BK LED 12 FRONT LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A N.C. L7 MODEL: L15 L16 DC LOW BATTERY WH INDICATOR L5 SW12 RD AUXILIARY DOWN OR RD BL RD WH RD RD OR BK RD/YL BK BN BL RD WH 5 BK RD 10 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 BK BK RD/BLK BK Y7 TERMINAL STRIP OR BK FRONT LEFT INTERLOCK FRONT RIGHT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK N.C. PLATFORM DOWN 2 3 YL OR GN/YL W4 NARROW BASE BL WH BK 4 WH RD GND OR WH PR4 BK EN4 15A CIRCUIT BREAKER 110V AC MODELS CB4 POWER TO PLATFORM GFCI RECEPTACLE 8A CIRCUIT BREAKER 220V AC MODELS QD4 WH WH BL WH 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH 6 WH GN/YL BN BK 7 BK WH GN/YL H4 GND GN/YL WH GN/YL BK WH STRAIN RELIEF DESCENT ALARM GROUND STUD 7 TO MOTOR RD BL OR WH YL 1 3 BL *N8 MOTOR 110V AC MOTOR DETAIL 2 4 GND OR YL EN6 WH 1 3 BK J-BOX WH M5 N.O. DUMP VALVE BK J-BOX GROUND SCREW Y30 GN/YL OPTIONAL WARNING LIGHT AND DESCENT ALARM EN5 WH WARNING LIGHT BK GROUND SCREW BK GN/YL FB2 WH BN BL D5 POWER SUPPLY AC 5 BK GROUND STUD TO PLUG BK 7 STRAIN RELIEF WH 6 110V AC TERMINAL STRIP DETAIL TERMINAL STRIP WH BN RD RD BK 7 BK OR GN/YL 4 5 6 RD BL OR WHT 1 2 3 4 5 GN/YL BL WH GN/YL GROUND STUD 1 2 3 *N7 W5 UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL AND BN WIRES. WH WH *N27 WH BK BK BL WH BL OR SW15 SW16 SW14 SW13 W6 WHT OR QD3 BK BL 6 BN BN GROUND STUD BK RD YL N.O. *N17 GN/YL 4 GROUND PC BOARD RD 3 UP SIGNAL OUTPUT U10 POWER INDICATOR UP DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. LOW BATTERY INDICATOR FOR AUXILIARY LOWERING BK BK 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT LEFT LEVELING LEVELING LED 15 REAR RIGHT INDICATORS INDICATOR LED 14 REAR LEFT INPUTS 2 3 L13 L14 8 AA BATTERIES YL BK 1 2 L6 B4 RD RD RD WH TRANSFORMER RD 16.0V DC INPUT 1 + EMERGENCY STOP W3 CENTER TAP INPUT BK FOR 240 V OPERATION JUMPER BROWN TO WHITE THROUGH TERMINAL STRIP AND LEAVE BLACK UNCONNECTED AS SHOWN U9 WH N.C. SW8 PLATFORM UP/DOWN BK BASE MODE CONTROL ACTIVATE SW11 2 BN EMERGENCY STOP GROUND CONTROL BOX BK RD PLATFORM CONTROL BOX B1 B WH EN2 3 RD 4 BK BK EN1 WH - RD/BLK RD M5 Y30 N.O. DUMP VALVE 8 *N10 MOTOR 220 V AC MOTOR DETAIL 2 4 GND ES0071_F Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 18 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models with Narrow Base (from serial number AWP07-54899 to AWP07-57594) ABBREVIATION LEGEND Item Description B4 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Warning light Ground Descent alarm Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units with out plug: WH and BK wires replace BL and BN wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 8 pole 16 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve FB2 GND H4 KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK RD/YL WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models with Standard Base (after serial number AWP07-57594) N M L K J I H G F E D C *N28 PLATFORM CONTROL BOX RD BK RD/BLK N.C. WH 1 BN BASE MODE RD WH 2 BK - EMERGENCY STOP EN1 EN2 3 RD B1 BK P2 WH PLATFORM MODE BL KEY SWITCH 1 P1 SW8 CONTROL ACTIVATE BK SW11 BK PLATFORM UP/DOWN RD RD BK YL 1 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT LEFT 2 2 3 LEVELING INDICATORS + EMERGENCY STOP B4 RD L12 L14 L5 SW12 RD BL WH GND RD WH 6 LED 12 FRONT LEFT 7 OR RD BL RD BK BK BK 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 13 1 2 N.C. PLATFORM DOWN YL RD/BLK UP SIGNAL INPUT FRONT RIGHT INTERLOCK FRONT LEFT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK Y7 TERMINAL STRIP BK 12 SW15 SW16 SW13 SW14 W6 RD GN/YL BL WHT 3 OR STANDARD BASE BK OR W4 CB9 4 OR PR4 BK WH GN/YL EN4 QD4 POWER TO PLATFORM GFCI RECEPTACLE GN/YL GN/YL GN/YL WH WH GN/YL 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH 6 *N29 *N30 (N) DENOTES A NEUTRAL WIRE TO BE TAGGED WITH AN (N) SLEEVE 110V AC / 220V AC TERMINAL STRIP DETAIL GN/YL GN/YL H4 7 STRAIN RELIEF DESCENT ALARM TO MOTOR RD BL OR WH YL 1 3 BL *N8 MOTOR 110V AC MOTOR DETAIL 2 4 GND OR YL EN6 WH 1 3 BK J-BOX M5 Y30 N.O. DUMP VALVE WH M5 BK J-BOX N.O. DUMP VALVE GN/YL OPTIONAL WARNING LIGHT AND DESCENT ALARM EN5 GROUND SCREW Y30 WH WARNING LIGHT BK GROUND SCREW BK WH FB2 GN/YL *N27 UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL AND BN WIRES. WH D5 POWER SUPPLY AC BK 7 TERMINAL STRIP 7 WH BK 6 W5 5 BK OR TO PLUG WH 7 BK 6 RD 4 5 GN/YL BL OR WHT 1 2 3 4 5 N WH BL WH BN N WH WH WH N WH BK WH GN/YL BK RD BL BN GN/YL RD BK GN/YL OR BL WHT 1 2 3 N BK STRAIN RELIEF QD3 N BL BN N 240V AC MODELS BK WH CB4 8A CIRCUIT BREAKER WH 15A CIRCUIT BREAKER 120V AC MODELS GROUND STUD BK RD BK BL 11 WH 6A CIRCUIT BREAKER 120V AC MODELS 3A CIRCUIT BREAKER 240V AC MODELS GN/YL RD BK OR 5 LED 14 REAR LEFT UP SIGNAL OUTPUT WH GROUND STUD RD WH RD/YL BK BN BL RD BN BN *N17 BK YL A WH WH 4 PC BOARD RD N.O. BL 3 UP SIGNAL OUTPUT (DELAYED) U10 TRANSFORMER RD LED 15 REAR RIGHT L7 DC MODEL: LOW BATTERY INDICATOR POWER INDICATOR AUXILIARY DOWN LEVELING INDICATOR INPUTS LOW BATTERY INDICATOR FOR AUXILIARY LOWERING N.C. UP OR L6 L13 L15 8 AA BATTERIES WH DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. W3 16.0V DC INPUT FOR 120V OPERATION JUMPER BROWN TO BLACK AND BLUE TO WHITE AS SHOWN WITH DASHED LINES (CB4 = 15A, CB9 = 6A) U9 GROUND CONTROL BOX BK KS1 FOR 240 V OPERATION JUMPER BROWN TO WHITE THROUGH TERMINAL STRIP AND LEAVE BLACK UNCONNECTED AS SHOWN (CB4 = 8A, CB9 = 3A) B 8 *N10 MOTOR 220 V AC MOTOR DETAIL 2 4 GND ES0071_J Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 19 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models with Standard Base (after serial number AWP07-57594) ABBREVIATION LEGEND Item Description B4 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Warning light Ground Descent alarm Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units with out plug: WH and BK wires replace BL and BN wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 8 pole 16 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve FB2 GND H4 KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK RD/YL WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. First Edition • Second Printing Section 7 • Schematics Electrical Schematic AWP Super Series AC Models with Narrow Base (after serial number AWP07-57594) N M L K J I H G F E D C *N28 PLATFORM CONTROL BOX RD BK RD/BLK N.C. WH 1 BN BASE MODE RD WH 2 BK - EMERGENCY STOP EN1 EN2 3 RD B1 BK P2 WH PLATFORM MODE BL KEY SWITCH 1 P1 SW8 CONTROL ACTIVATE BK SW11 BK PLATFORM UP/DOWN RD RD BK YL 1 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT LEFT 2 2 3 LEVELING INDICATORS + EMERGENCY STOP B4 RD L14 L15 L5 SW12 RD BL WH GND RD WH 6 LED 12 FRONT LEFT 7 BL RD RD RD BK BK BK 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 13 1 2 N.C. PLATFORM DOWN YL RD/BLK UP SIGNAL INPUT FRONT LEFT INTERLOCK FRONT RIGHT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK Y7 TERMINAL STRIP BK 12 SW15 SW16 SW14 SW13 W6 RD GN/YL BL WHT 3 OR NARROW BASE BK OR W4 CB9 4 OR PR4 BK WH GN/YL EN4 QD4 POWER TO PLATFORM GFCI RECEPTACLE GN/YL GN/YL GN/YL WH WH GN/YL 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH *N29 *N30 6 (N) DENOTES A NEUTRAL WIRE TO BE TAGGED WITH AN (N) SLEEVE 110V AC / 220V AC TERMINAL STRIP DETAIL GN/YL GN/YL H4 7 STRAIN RELIEF DESCENT ALARM TO MOTOR RD BL OR WH YL 1 3 BL *N8 MOTOR 110V AC MOTOR DETAIL 2 4 GND OR YL EN6 WH 1 3 BK J-BOX M5 Y30 N.O. DUMP VALVE WH M5 BK J-BOX N.O. DUMP VALVE GN/YL OPTIONAL WARNING LIGHT AND DESCENT ALARM EN5 GROUND SCREW Y30 WH WARNING LIGHT BK GROUND SCREW BK WH FB2 GN/YL *N27 UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL AND BN WIRES. WH D5 POWER SUPPLY AC BK 7 TERMINAL STRIP 7 WH BK 6 W5 5 BK OR TO PLUG WH 7 BK 6 RD 4 5 GN/YL BL OR WHT 1 2 3 4 5 N WH BL WH BN N WH WH WH N WH BK WH GN/YL BK RD BL BN GN/YL RD BK GN/YL OR BL WHT 1 2 3 N BK STRAIN RELIEF QD3 N BL BN N 240V AC MODELS BK WH CB4 8A CIRCUIT BREAKER WH 15A CIRCUIT BREAKER 120V AC MODELS GROUND STUD BK RD BK BL 11 WH 6A CIRCUIT BREAKER 120V AC MODELS 3A CIRCUIT BREAKER 240V AC MODELS GN/YL OR BK OR 5 LED 14 REAR LEFT UP SIGNAL OUTPUT WH GROUND STUD RD WH RD/YL BK BN BL RD BN BN *N17 BK YL A WH WH 4 PC BOARD RD N.O. BL 3 UP SIGNAL OUTPUT (DELAYED) U10 TRANSFORMER RD LED 15 REAR RIGHT L7 DC MODEL: LOW BATTERY INDICATOR POWER INDICATOR AUXILIARY DOWN LEVELING INDICATOR INPUTS LOW BATTERY INDICATOR FOR AUXILIARY LOWERING N.C. UP OR L6 L12 L13 8 AA BATTERIES WH DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. W3 16.0V DC INPUT FOR 120V OPERATION JUMPER BROWN TO BLACK AND BLUE TO WHITE AS SHOWN WITH DASHED LINES (CB4 = 15A, CB9 = 6A) U9 GROUND CONTROL BOX BK KS1 FOR 240 V OPERATION JUMPER BROWN TO WHITE THROUGH TERMINAL STRIP AND LEAVE BLACK UNCONNECTED AS SHOWN (CB4 = 8A, CB9 = 3A) B 8 *N10 MOTOR 220 V AC MOTOR DETAIL 2 4 GND ES0071_J Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 20 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC Models with Narrow Base (after serial number AWP07-57594) ABBREVIATION LEGEND Item Description B1 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN3 = Remote box (ce option) EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board U12 = Thermal device Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve GND KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BN BK GN/YL OR RD RD/YL WH Y Description Blue Brown Black Green/Yellow Orange Red Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC CE Models (from serial number 3896-451 to AWP07-54898) M L K J I H G F E D C B A 1 KS1 N.O. RD BK N.O. BK TRANSFORMER RD 1 GROUND RD + N.O. RD N.C. N.C. L14 L12 RD L15 L13 YL 5 LED 13 REAR RIGHT 6 LED 15 REAR LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 UP SIGNAL OUTPUT 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 PC BOARD RD BL 2 WH OR BL RD BK RD 3 WH BK OR W4 OR WH PR4 WH 15A CIRCUIT BREAKER 110V AC MODELS BK WH BL BK 5 W5 TERMINAL STRIP BK SW11 TERMINAL STRIP WH GN/YL WH BN WH WT BK GND WH BN WH BK WH PLATFORM UP/DOWN WT 110V AC TERMINAL STRIP DETAIL W5 BK GN/YL BK *N7 WH WH WH BK BK BK GROUND STUD WH GND RD N.C. BL WH U12 BN 8A CIRCUIT BREAKER 220V AC MODELS EMERGENCY STOP YL TRANSFORMER U9 BK CB4 P2 220V AC TERMINAL STRIP DETAIL WH WH BK 4 *N9 WH BL BK WIRE DISCONNECTED OR PLATFORM CONTROL BOX WH LED 12 FRONT RIGHT BN N.O. EN1 CONTROL ACTIVATE 4 WH RD/YL RD BN SW8 2 3 L6 U10 CENTER TAP INPUT 16.0V DC INPUT LOW BATTERY INDICATOR FOR AUXILIARY LOWERING L7 1 LED 14 FRONT LEFT POWER INDICATOR DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN REMOTE BOX (CE OPTION) LEVELING INDICATOR INPUTS L5 SW12 EN3 W3 16.0V DC INPUT RD WH BK 3 LEVELING INDICATORS BK 8 AA BATTERIES EMERGENCY STOP 2 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT POSITIVE 12V DC AUX. INPUT B1 P1 RD YL BK KS1 N.O. RD THERMAL DEVICE U9 BL BK BK RD U12 BK PLATFORM - 6 GROUND STUD UP BK EN2 BL EN4 POWER TO PLATFORM GFCI RECEPTACLE 110V AC / 220V AC WH GN/YL BK WH GROUND STUD GN/YL 1 3 5 2 4 8 M5 *N8 MOTOR GND 110V AC MOTOR DETAIL REAR LEFT INTERLOCK REAR RIGHT INTERLOCK SW15 SW16 W6 TERMINAL STRIP FRONT RIGHT INTERLOCK 7 FRONT LEFT INTERLOCK RD BK 6 BK BN 5 BK WH 4 BK BL OR WH 3 7 TO BASE GROUND SCREW N.O. DUMP VALVE EN5 2 QUICK DISCONNECT B SW14 BK WH RD OR Y30 GROUND SCREW 1 Y30 1 4 8 M5 2 3 4 5 6 7 BK N.O. DUMP VALVE EN6 1 *N10 RD RD BL RD OR RD WH RD YL N.C. PLATFORM DOWN 220V AC MOTOR DETAIL MOTOR GND GN/YL BK Part No. 38139 SW13 TO MOTOR 7 BK 6 WH 4 WH 3 GN/YL 2 QD4 STRAIN RELIEF GN/YL TO PLATFORM 1 QD7 BK 7 BK 6 GROUND STUD WH 4 BASE GROUND CONTROL BOX GND GN/YL 3 BK RD BK 2 QUICK DISCONNECT A WH GN/YL 1 OR QD3 BL RD POWER SUPPLY AC WH WH D5 BL NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. BK *N17 BK WH BK GN/YL DOWN OR N 8 Y7 Genie AWP Super Series and Genie IWP Super Series 7 - 21 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC CE Models (from serial number 3896-451 to AWP07-54898) ABBREVIATION LEGEND Item Description B4 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Warning light Ground Descent alarm Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units with out plug: WH and BK wires replace BL and BN wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 8 pole 16 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve FB2 GND H4 KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK RD/YL WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC CE Models with Standard Base (from serial number AWP07-54899 to AWP07-57594) N M L K J I H G F E D C B A RD/BLK 1 KS1 PLATFORM MODE KEY SWITCH P2 BN BK 1 P1 BK 2 L6 LOW BATTERY INDICATOR FOR AUXILIARY LOWERING N.C. MODEL: L12 L14 DC LOW BATTERY INDICATOR L5 RD AUXILIARY DOWN RD RD RD OR RD WH BL RD OR BK RD/YL RD WH 5 6 LED 12 FRONT LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A BK RD GROUND 10 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 BK BK RD/BLK BK WH BK BK N.C. PLATFORM DOWN 2 3 YL OR GN/YL W4 4 WH RD OR WH PR4 BK EN4 8A CIRCUIT BREAKER 220V AC MODELS 15A CIRCUIT BREAKER 110V AC MODELS CB4 POWER TO PLATFORM GFCI RECEPTACLE QD4 WH WH BL WH 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH 6 WH GN/YL BN BK 7 BK WH GN/YL H4 GND GN/YL WH GN/YL BK WH GROUND STUD 7 STRAIN RELIEF DESCENT ALARM TO MOTOR RD BL OR WH YL 1 3 BL *N8 MOTOR 110V AC MOTOR DETAIL 2 4 GND OR YL EN6 WH 1 3 BK J-BOX WH M5 N.O. DUMP VALVE BK J-BOX GROUND SCREW Y30 GN/YL OPTIONAL WARNING LIGHT AND DESCENT ALARM EN5 WH WARNING LIGHT BK GROUND SCREW BK GN/YL FB2 WH BN BL D5 POWER SUPPLY AC 5 BK GROUND STUD TO PLUG BK 7 STRAIN RELIEF WH 6 110V AC TERMINAL STRIP DETAIL TERMINAL STRIP WH BN RD RD BK 7 BK OR GN/YL 4 5 6 RD BL OR WHT 1 2 3 4 5 GN/YL BL WH GN/YL GROUND STUD 1 2 3 *N7 W5 UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL AND BN WIRES. WH WH *N27 WH BK BK BL WH BL OR Y7 TERMINAL STRIP OR FRONT RIGHT INTERLOCK FRONT LEFT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK STANDARD BASE GND QD3 SW15 SW16 SW13 SW14 W6 WHT OR BL BK BL BN BN GROUND STUD BK WH YL BK BN BL N.O. *N17 GN/YL 4 LED 14 REAR LEFT PC BOARD RD 3 UP SIGNAL OUTPUT U10 POWER INDICATOR UP SW12 TRANSFORMER RD LED 15 REAR RIGHT L7 WH DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. LEVELING INDICATOR INPUTS BK BK 1 L13 L15 8 AA BATTERIES YL BK B4 RD RD RD 16.0V DC INPUT 3 LEVELING INDICATORS + EMERGENCY STOP W3 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT RIGHT 2 FOR 240 V OPERATION JUMPER BROWN TO WHITE THROUGH TERMINAL STRIP AND LEAVE BLACK UNCONNECTED AS SHOWN U9 WH 1 N.C. SW8 PLATFORM UP/DOWN 2 BASE MODE RD CONTROL ACTIVATE SW11 BK B GROUND CONTROL BOX BK RD PLATFORM CONTROL BOX B1 EMERGENCY STOP WH EN2 3 RD 4 BK BK EN1 WH - RD/BLK RD M5 Y30 N.O. DUMP VALVE 8 *N10 MOTOR 220 V AC MOTOR DETAIL 2 4 GND ES0071_F Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 22 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC CE Models with Standard Base (from serial number AWP07-54899 to AWP07-57594) ABBREVIATION LEGEND Item Description B4 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Warning light Ground Descent alarm Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units with out plug: WH and BK wires replace BL and BN wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 8 pole 16 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve FB2 GND H4 KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK RD/YL WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. First Edition • Second Printing Section 7 • Schematics Electrical Schematic AWP Super Series AC CE Models with Narrow Base (from serial number AWP07-54899 to AWP07-57594) N M L K J I H G F E D C B A RD/BLK 1 KS1 PLATFORM MODE KEY SWITCH P2 RD 1 P1 BK LED 12 FRONT LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A N.C. L7 MODEL: L15 L16 DC LOW BATTERY WH INDICATOR L5 SW12 RD AUXILIARY DOWN OR RD BL RD WH RD RD OR BK RD/YL BK BN BL RD WH 5 BK RD 10 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 BK BK RD/BLK BK Y7 TERMINAL STRIP OR BK FRONT LEFT INTERLOCK FRONT RIGHT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK N.C. PLATFORM DOWN 2 3 YL OR GN/YL W4 NARROW BASE BL WH BK 4 WH RD GND OR WH PR4 BK EN4 15A CIRCUIT BREAKER 110V AC MODELS CB4 POWER TO PLATFORM GFCI RECEPTACLE 8A CIRCUIT BREAKER 220V AC MODELS QD4 WH WH BL WH 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH 6 WH GN/YL BN BK 7 BK WH GN/YL H4 GND GN/YL WH GN/YL BK WH STRAIN RELIEF DESCENT ALARM GROUND STUD 7 TO MOTOR RD BL OR WH YL 1 3 BL *N8 MOTOR 110V AC MOTOR DETAIL 2 4 GND OR YL EN6 WH 1 3 BK J-BOX WH M5 N.O. DUMP VALVE BK J-BOX GROUND SCREW Y30 GN/YL OPTIONAL WARNING LIGHT AND DESCENT ALARM EN5 WH WARNING LIGHT BK GROUND SCREW BK GN/YL FB2 WH BN BL D5 POWER SUPPLY AC 5 BK GROUND STUD TO PLUG BK 7 STRAIN RELIEF WH 6 110V AC TERMINAL STRIP DETAIL TERMINAL STRIP WH BN RD RD BK 7 BK OR GN/YL 4 5 6 RD BL OR WHT 1 2 3 4 5 GN/YL BL WH GN/YL GROUND STUD 1 2 3 *N7 W5 UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL AND BN WIRES. WH WH *N27 WH BK BK BL WH BL OR SW15 SW16 SW14 SW13 W6 WHT OR QD3 BK BL 6 BN BN GROUND STUD BK RD YL N.O. *N17 GN/YL 4 GROUND PC BOARD RD 3 UP SIGNAL OUTPUT U10 POWER INDICATOR UP DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. LOW BATTERY INDICATOR FOR AUXILIARY LOWERING BK BK 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT LEFT LEVELING LEVELING LED 15 REAR RIGHT INDICATORS INDICATOR LED 14 REAR LEFT INPUTS 2 3 L13 L14 8 AA BATTERIES YL BK 1 2 L6 B4 RD RD RD WH TRANSFORMER RD 16.0V DC INPUT 1 + EMERGENCY STOP W3 CENTER TAP INPUT BK FOR 240 V OPERATION JUMPER BROWN TO WHITE THROUGH TERMINAL STRIP AND LEAVE BLACK UNCONNECTED AS SHOWN U9 WH N.C. SW8 PLATFORM UP/DOWN BK BASE MODE CONTROL ACTIVATE SW11 2 BN EMERGENCY STOP GROUND CONTROL BOX BK RD PLATFORM CONTROL BOX B1 B WH EN2 3 RD 4 BK BK EN1 WH - RD/BLK RD M5 Y30 N.O. DUMP VALVE 8 *N10 MOTOR 220 V AC MOTOR DETAIL 2 4 GND ES0071_F Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 23 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC CE Models with Narrow Base (from serial number AWP07-54899 to AWP07-57594) ABBREVIATION LEGEND Item Description B4 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Warning light Ground Descent alarm Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units with out plug: WH and BK wires replace BL and BN wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 8 pole 16 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve FB2 GND H4 KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK RD/YL WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC CE Models with Standard Base (after serial number AWP07-57594) N M L K J I H G F E D C *N28 PLATFORM CONTROL BOX RD BK RD/BLK N.C. WH 1 BN BASE MODE RD WH 2 BK - EMERGENCY STOP EN1 EN2 3 RD B1 BK P2 WH PLATFORM MODE BL KEY SWITCH 1 P1 SW8 CONTROL ACTIVATE BK SW11 BK PLATFORM UP/DOWN RD RD BK YL 1 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT LEFT 2 2 3 LEVELING INDICATORS + EMERGENCY STOP B4 RD L12 L14 L5 SW12 RD BL WH GND RD WH 6 LED 12 FRONT LEFT 7 OR RD BL RD BK BK BK 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 13 1 2 N.C. PLATFORM DOWN YL RD/BLK UP SIGNAL INPUT FRONT RIGHT INTERLOCK FRONT LEFT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK Y7 TERMINAL STRIP BK 12 SW15 SW16 SW13 SW14 W6 RD GN/YL BL WHT 3 OR STANDARD BASE BK OR W4 CB9 4 OR PR4 BK WH GN/YL EN4 QD4 POWER TO PLATFORM GFCI RECEPTACLE GN/YL WH BL WH BN GN/YL GN/YL WH WH GN/YL W5 TERMINAL STRIP 7 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH *N29 *N30 6 (N) DENOTES A NEUTRAL WIRE TO BE TAGGED WITH AN (N) SLEEVE 110V AC / 220V AC TERMINAL STRIP DETAIL GN/YL WH 7 STRAIN RELIEF DESCENT ALARM TO MOTOR RD BL OR WH YL 1 3 BL *N8 MOTOR 110V AC MOTOR DETAIL 2 4 GND OR YL EN6 WH 1 3 BK J-BOX WH M5 BK J-BOX N.O. DUMP VALVE GN/YL OPTIONAL WARNING LIGHT AND DESCENT ALARM EN5 GROUND SCREW Y30 WH WARNING LIGHT BK GROUND SCREW BK WH FB2 GN/YL *N27 UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL AND BN WIRES. GN/YL H4 BK D5 POWER SUPPLY AC WH BK 7 N 5 BK OR TO PLUG WH 6 WH WH WH N WH BK BL WH GN/YL BK RD RD BL GN/YL 7 BK 4 5 6 RD OR BL WHT 1 2 3 4 5 GN/YL 1 2 3 N N STRAIN RELIEF QD3 N BK BK GN/YL OR BL WHT BN 240V AC MODELS BK N BN WH CB4 8A CIRCUIT BREAKER WH 15A CIRCUIT BREAKER 120V AC MODELS GROUND STUD BK RD BK BL 11 WH 6A CIRCUIT BREAKER 120V AC MODELS 3A CIRCUIT BREAKER 240V AC MODELS GN/YL RD BK OR 5 LED 14 REAR LEFT UP SIGNAL OUTPUT WH GROUND STUD RD WH RD/YL BK BN BL RD BN BN *N17 BK YL A WH WH 4 PC BOARD RD N.O. BL 3 UP SIGNAL OUTPUT (DELAYED) U10 TRANSFORMER RD LED 15 REAR RIGHT L7 DC MODEL: LOW BATTERY INDICATOR POWER INDICATOR AUXILIARY DOWN LEVELING INDICATOR INPUTS LOW BATTERY INDICATOR FOR AUXILIARY LOWERING N.C. UP OR L6 L13 L15 8 AA BATTERIES WH DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. W3 16.0V DC INPUT FOR 120V OPERATION JUMPER BROWN TO BLACK AND BLUE TO WHITE AS SHOWN WITH DASHED LINES (CB4 = 15A, CB9 = 6A) U9 GROUND CONTROL BOX BK KS1 FOR 240 V OPERATION JUMPER BROWN TO WHITE THROUGH TERMINAL STRIP AND LEAVE BLACK UNCONNECTED AS SHOWN (CB4 = 8A, CB9 = 3A) B M5 Y30 N.O. DUMP VALVE 8 *N10 MOTOR 220 V AC MOTOR DETAIL 2 4 GND ES0071_J Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 24 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC CE Models with Standard Base (after serial number AWP07-57594) ABBREVIATION LEGEND Item Description B4 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Warning light Ground Descent alarm Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units with out plug: WH and BK wires replace BL and BN wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 8 pole 16 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve FB2 GND H4 KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK RD/YL WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. First Edition • Second Printing Section 7 • Schematics Electrical Schematic AWP Super Series AC CE Models with Narrow Base (after serial number AWP07-57594) N M L K J I H G F E D C *N28 PLATFORM CONTROL BOX RD BK RD/BLK N.C. WH 1 BN BASE MODE RD WH 2 BK - EMERGENCY STOP EN1 EN2 3 RD B1 BK P2 WH PLATFORM MODE BL KEY SWITCH 1 P1 SW8 CONTROL ACTIVATE BK SW11 BK PLATFORM UP/DOWN RD RD BK YL 1 CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT LEFT 2 2 3 LEVELING INDICATORS + EMERGENCY STOP B4 RD L14 L15 L5 SW12 RD BL WH GND RD WH 6 LED 12 FRONT LEFT 7 BL RD RD RD BK BK BK 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 13 1 2 N.C. PLATFORM DOWN YL RD/BLK UP SIGNAL INPUT FRONT LEFT INTERLOCK FRONT RIGHT INTERLOCK REAR RIGHT INTERLOCK REAR LEFT INTERLOCK Y7 TERMINAL STRIP BK 12 SW15 SW16 SW14 SW13 W6 RD GN/YL BL WHT 3 OR NARROW BASE BK OR W4 CB9 4 OR PR4 BK WH GN/YL EN4 QD4 POWER TO PLATFORM GFCI RECEPTACLE GN/YL WH BL WH BN GN/YL GN/YL WH WH GN/YL W5 TERMINAL STRIP 7 7 BK RD 6 6 RD BN 5 5 WH 4 4 YL GN/YL OR 3 3 OR BL 2 2 WH 1 1 BL WH *N29 *N30 6 (N) DENOTES A NEUTRAL WIRE TO BE TAGGED WITH AN (N) SLEEVE 110V AC / 220V AC TERMINAL STRIP DETAIL GN/YL WH 7 STRAIN RELIEF DESCENT ALARM TO MOTOR RD BL OR WH YL 1 3 BL *N8 MOTOR 110V AC MOTOR DETAIL 2 4 GND OR YL EN6 WH 1 3 BK J-BOX WH M5 BK J-BOX N.O. DUMP VALVE GN/YL OPTIONAL WARNING LIGHT AND DESCENT ALARM EN5 GROUND SCREW Y30 WH WARNING LIGHT BK GROUND SCREW BK WH FB2 GN/YL *N27 UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL AND BN WIRES. GN/YL H4 BK D5 POWER SUPPLY AC WH BK 7 N 5 BK OR TO PLUG WH 6 WH WH WH N WH BK BL WH GN/YL BK RD RD BL GN/YL 7 BK 4 5 6 RD OR BL WHT 1 2 3 4 5 GN/YL 1 2 3 N N STRAIN RELIEF QD3 N BK BK GN/YL OR BL WHT BN 240V AC MODELS BK N BN WH CB4 8A CIRCUIT BREAKER WH 15A CIRCUIT BREAKER 120V AC MODELS GROUND STUD BK RD BK BL 11 WH 6A CIRCUIT BREAKER 120V AC MODELS 3A CIRCUIT BREAKER 240V AC MODELS GN/YL OR BK OR 5 LED 14 REAR LEFT UP SIGNAL OUTPUT WH GROUND STUD RD WH RD/YL BK BN BL RD BN BN *N17 BK YL A WH WH 4 PC BOARD RD N.O. BL 3 UP SIGNAL OUTPUT (DELAYED) U10 TRANSFORMER RD LED 15 REAR RIGHT L7 DC MODEL: LOW BATTERY INDICATOR POWER INDICATOR AUXILIARY DOWN LEVELING INDICATOR INPUTS LOW BATTERY INDICATOR FOR AUXILIARY LOWERING N.C. UP OR L6 L12 L13 8 AA BATTERIES WH DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. W3 16.0V DC INPUT FOR 120V OPERATION JUMPER BROWN TO BLACK AND BLUE TO WHITE AS SHOWN WITH DASHED LINES (CB4 = 15A, CB9 = 6A) U9 GROUND CONTROL BOX BK KS1 FOR 240 V OPERATION JUMPER BROWN TO WHITE THROUGH TERMINAL STRIP AND LEAVE BLACK UNCONNECTED AS SHOWN (CB4 = 8A, CB9 = 3A) B M5 Y30 N.O. DUMP VALVE 8 *N10 MOTOR 220 V AC MOTOR DETAIL 2 4 GND ES0071_J Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 25 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC CE Models with Narrow Base (after serial number AWP07-57594) ABBREVIATION LEGEND Item Description B1 CB4 D5 EN Battery — 8 AA batteries Circuit breaker, 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN3 = Remote box (ce option) EN4 = Power to platform GFCI receptacle EN6 = Power unit — 220V AC Ground Key switch ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Hydraulic power unit Key switch Hydraulic power unit Normally closed Normally open Note with description *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW13 = Outrigger interlock — front left SW14 = Outrigger interlock — front right SW15 = Outrigger interlock — rear left SW16 = Outrigger interlock — rear right Electronic component U9 = Transformer U10 = PC board U12 = Thermal device Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (*N7,*N9) W6 = Terminal strip — 6 pole 12 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve GND KS1 L M5 KS1 M5 N.C. N.O *N P PR QD SW U W Y WIRE COLOR LEGEND Color BL BN BK GN/YL OR RD RD/YL WH Y Description Blue Brown Black Green/Yellow Orange Red Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC TUV Models (after serial number 3896-460) M L K J I H G F E D C B A 1 KS1 U12 GROUND/ PLATFORM RD N.O. RD BK N.O. BK BK RD N.C. N.C. 1 + EMERGENCY STOP BK YL L14 L12 L15 L13 AUXILIARY DOWN OR 1 CENTER TAP INPUT 2 16.0V DC INPUT 3 4 LED 12 FRONT RIGHT 5 LED 13 REAR RIGHT 6 LED 15 REAR LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A POWER INDICATOR L6 LOW BATTERY INDICATOR FOR AUXILIARY LOWERING GROUND 10 UP SIGNAL OUTPUT 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 RD WH RD/YL BN RD BL 2 WH OR BL RD BK RD 3 WH BK OR W4 OR WH 4 CB4 P2 8A CIRCUIT BREAKER 5 BK SW11 *N9 WH WH BL BK BK GROUND STUD N.C. WH GND RD WH WH PR4 BK EMERGENCY STOP WH YL WH PLATFORM CONTROL BOX SW8 16.0V DC INPUT LED 14 FRONT LEFT U10 PC BOARD DC MODEL: LOW BATTERY INDICATOR RD BL L7 BL EN1 CONTROL ACTIVATE LEVELING INDICATOR INPUTS L5 SW12 REMOTE BOX W3 LEVELING INDICATORS 8 AA BATTERIES EN3 3 BK B4 BL 2 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT POSITIVE 12V DC AUX. INPUT BL N.O. TRANSFORMER THERMAL DEVICE BK P1 RD U9 RD - 220V AC TERMINAL STRIP DETAIL W5 TERMINAL STRIP WH GN/YL GND WH BN WH BK WH BK PLATFORM UP/DOWN 6 GROUND STUD UP BK EN2 110V AC / 220V AC WH GN/YL BK WH GROUND STUD GN/YL 1 4 8 M5 REAR RIGHT INTERLOCK 2 3 4 5 6 7 BK *N10 RD RD BL RD OR RD WH RD YL N.C. PLATFORM DOWN 220V AC MOTOR DETAIL MOTOR SW16 W6 BK 7 BK 6 BK BK BL WH RD BL OR 5 7 TO BASE 1 N.O. DUMP VALVE EN6 GN/YL BK EN4 POWER TO PLATFORM GFCI RECEPTACLE WH OR BL Y30 GROUND SCREW 4 REAR LEFT INTERLOCK TO MOTOR 7 3 SW15 6 2 QUICK DISCONNECT B FRONT RIGHT INTERLOCK 4 1 SW14 3 RD QD4 FRONT LEFT INTERLOCK 2 STRAIN RELIEF SW13 TO PLATFORM 1 QD7 WH 7 BASE BK 6 GROUND STUD WH 4 GROUND CONTROL BOX GND GN/YL 3 WH 2 QUICK DISCONNECT A BK RD BK 1 GN/YL WH QD3 OR RD POWER SUPPLY AC BL WH D5 BL NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. BK *N17 BK WH BK GN/YL DOWN OR N GND GN/YL BK Part No. 38139 8 Y7 Genie AWP Super Series and Genie IWP Super Series 7 - 26 Section 7 • Schematics First Edition • Second Printing Electrical Schematic AWP Super Series AC TUV Models (after serial number 3896-460) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW24 = Lift enable Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK GN GN/YL OR RD WH WH/BK YL Description Blue Black Green Green/Yellow Orange Red White White/Black Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models (from serial number 4096-101 to 4096-287) M L K J I H G F E D C B A 1 P1 BK EMERGENCY STOP BK BK BK RD N.C. 1 KS1 BK 2 1 LEVELING INDICATORS 2 3 LED 1 12V DC INPUT 4 LED 2 12V DC INPUT 5 L5 LED 3 12V DC INPUT 6 POWER INDICATOR BK N.O. L14 L12 BK L15 L13 B4 LED 4 12V DC INPUT 7 L6 12V DC OUTPUT 8 INDICATOR FOR AUXILIARY LOWERING 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 12V DC MOTOR SOLENOID OUTPUT 11 8 AA BATTERIES 1 SECOND TIME DELAY 12V DC OUTPUT 12 L7 SW12 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN U10 N.O. 12V DC UP SIGNAL INPUT 13 2 WH OR BL RD BK RD RD GN/YL 3 RD S7 TILT SENSOR OR W4 PC BOARD RD RD BK OR WH BK GN 4 WH WH W3 3 12V DC POWER INPUT NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT + GROUND/ PLATFORM P2 W6 EMERGENCY STOP QD4 GND PLATFORM CONTROL SW8 CONTROL BOX ACTIVATE BK BK 5 WH/BK 3 OR SW18 2 BL BK 1 WH SW17 BK GN GN 6 BK RD WH BL WH GND B2 + BATTERY 12V DC - GN/YL BK BK BK POWER GN/YL INPUT PLUG D5 POWER SUPPLY AC CHARGE BATTERY MOTOR BK BK BK GN/YL GN/YL YL RD BK BK BL M5 WH QD1(+) RD WH OR BK 7 OR 6 WH 4 WH 3 PLATFORM EXTENTION WH GN/YL GN/YL GN/YL 7 LS1 GN/YL 2 TO PLATFORM 7 RD WH 6 GN/YL 4 OR BK 5 DOWN 4 GN/YL STRAIN RELIEF BK BK 3 GN/YL 2 RD 110V AC / 220V AC WH 1 N.O. Y7 PLATFORM WH/BK WH RD PLATFORM OUTREACH OPTION QUICK DISCONNECT A TO PLATFORM GROUND STUD GN/YL BL 2 6 BK TO MOTOR RD WH QD3 1 OR POWER SUPPLY AC GN/YL BK WH D5 WH RD BK WH QD7 POWER INPUT PLUG 1 POWER TO PLATFORM GFCI RECEPTACLE 5 OR 3 EN2 UP BL NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. WH 6 7 GND GROUND STUD DOWN *N17 EN4 7 GN/YL 4 GROUND CONTROL BOX BK PLATFORM UP/DOWN SWITCH WH GND GROUND STUD GN/YL SW11 GROUND STUD RD WT SWITCH BK GN/YL TO BASE N.C. QUICK DISCONNECT B EN1 TERMINAL STRIP RD WH OR N BASE GN/YL QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE QD1(-) Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 27 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models (from serial number 4096-101 to 4096-287) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW24 = Lift enable Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK GN GN/YL OR RD WH WH/BK YL Description Blue Black Green Green/Yellow Orange Red White White/Black Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models (from serial number 4096-288 to 4096-341) M L K J I H G F E D C B A 1 P1 BK EMERGENCY STOP BK RD BK BK BK RD 1 N.C. 2 + KS1 GROUND/ PLATFORM RD BK BK LEVELING INDICATORS BK L15 L13 B4 3 LED 1 12V DC INPUT 4 LED 2 12V DC INPUT 5 LED 3 12V DC INPUT 6 LED 4 12V DC INPUT 7 L6 12V DC OUTPUT 8 INDICATOR FOR AUXILIARY LOWERING 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 12V DC MOTOR SOLENOID OUTPUT 11 8 AA BATTERIES 1 SECOND TIME DELAY 12V DC OUTPUT 12 L7 SW12 12V DC UP SIGNAL INPUT 13 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN 2 2 L5 L14 L12 - N.O. N.O. 1 POWER INDICATOR BK U10 WH OR BL RD BK RD RD 3 GN/YL RD S7 TILT SENSOR OR W4 PC BOARD RD RD BK OR WH BK GN 4 WH WH W3 3 12V DC POWER INPUT NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT RD W6 P2 TERMINAL STRIP EMERGENCY STOP RD QD4 GND PLATFORM CONTROL SW8 CONTROL BOX ACTIVATE BK GN/YL GROUND STUD RD WH GND 7 6 5 GN/YL 4 GROUND STUD OR 3 BL 2 WT SWITCH BK WH 1 7 6 TO BASE N.C. EN1 QUICK DISCONNECT B WH GND GROUND STUD BK BK 5 WH/BK 4 GN/YL 3 OR SW18 2 BL BK 1 WH SW17 RD WH STRAIN RELIEF BL WH GND BK B2 + BATTERY 12V DC - GN/YL BK BK BK POWER INPUT PLUG D5 GN/YL WH POWER SUPPLY AC CHARGE BATTERY MOTOR BK BK BK GN/YL GN/YL RD YL BK BK M5 BL QD1(+) OR RD WH WH BK 7 OR 6 OR 4 7 WH 3 GN/YL 2 TO PLATFORM PLATFORM EXTENTION WH GN/YL GN/YL WH QUICK DISCONNECT A RD 110V AC / 220V AC 6 LS1 GN/YL 7 RD WH 6 GN/YL 4 BK BK 3 GN/YL 2 PLATFORM OUTREACH OPTION TO MOTOR RD OR QD3 1 WH POWER SUPPLY AC WH D5 GN/YL BK WH GN/YL BK RD BK WH BL QD7 POWER INPUT PLUG TO PLATFORM GROUND STUD GN/YL GN BK UP 1 POWER TO PLATFORM GFCI RECEPTACLE GN DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. WH 5 DOWN BK *N17 EN4 N.O. Y7PLATFORM WH/BK WH RD SW11 PLATFORM UP/DOWN SWITCH OR N BASE GN/YL QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE QD1(-) Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 28 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models (from serial number 4096-288 to 4096-341) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW24 = Lift enable Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK GN GN/YL OR RD WH WH/BK YL Description Blue Black Green Green/Yellow Orange Red White White/Black Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models (from serial number 4096-342 to IWP07-7065) N M L K J I H G F E D C B A 1 2 3 4 5 6 7 8 Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 29 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models (from serial number 4096-342 to IWP07-7065) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power wheel Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Fuse — 175 Amp Warning light Ground Descent alarm Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L66 = Level sensor interlock L67 = Footpad interlock Hydraulic power unit Note with description *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units without plug: WH and BK wires replace BL and BN wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls P3 = Emergency Stop button at steer handle controls Quick disconnect QD1 = Battery quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Tilt sensor Switch SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW21 = Power assist, direction reversing safety SW22 = Power assist, forward/reverse SW41 = Power assist, drive enable Electronic component U9 = Battery charger U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 5 pole 10 pin Valve coil Y5 = Drive manifold, drive forward Y6 = Drive manifold, drive reverse Y7 = Platform down Y30 = Normally open dump valve Y32 = Drive enable, drive function CR96 D5 EN F11 FB2 GND H4 KS1 L M5 *N N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models (after serial number IWP07-7065) N M L K J I H G F E D C B A RD/BLK 1 KS1 KEY SWITCH P2 BASE MODE RD RD 1 RD EMERGENCY STOP SW8 BK BK BK 1 2 LEVELING INDICATORS L6 BK B4 N.C. 8 AA BATTERIES WH UP L67 L67 POWER INDICATOR AUXILIARY DOWN 7 9 12V DC OUTPUT 9A GROUND 10 UP SIGNAL OUTPUT 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 9 8 WH SW41 WHT DRIVE ENABLE SWITCH RD 4 5 P3 EMERGENCY STOP (OPTION) 6 BL WH WH 2 3 SW21 DIRECTION REVERSING SAFETY SWITCH BK OR OR GN/YL BK WH WH BK BK 5 J BOX POWER WHEEL OPTION RD QD4 WH YL BK 7 7 BK RD 6 6 RD BN 5 5 YL WH GN/YL OR 4 4 WH WH OR 3 3 OR WH 2 RD BL 2 RD WH 1 1 BL WH BL BL WH BK BK H4 RD BL FB2 BK OPTIONAL WARNING LIGHT AND DESCENT ALARM RD BK B2 U9 BATTERY CHARGER AC INPUT + - RD BK BATTERY 12V DC + - QD1 RD RD BK BK BK SW17 7 SW18 NC RD WARNING LIGHT 6 WH WH POWER UNIT WH BK N.C. PLATFORM DOWN WH DESCENT ALARM OR Y7 BK GN/YL GN/YL OR WH YL GN/YL GN/YL OR RD BK BK WH GN/YL WH CR96 BN GN/YL 30 87 BK TO MOTOR D5 BN DRIVE MANIFOLD STRAIN RELIEF TO PLUG POWER SUPPLY AC DRIVE FUNCTION BK BN RD 7 BL 6 OR 4 5 GN/YL 1 2 3 BL RD RD BN GN/YL OR BL BL BL GROUND STUD 7 87A BK STRAIN RELIEF 6 RD WH WH *N27 86 GN/YL 85 TERMINAL STRIP UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL(1) AND BN(7) WIRES. 4 5 Y6 DRIVE REVERSE GND W5 1 2 3 4 Y32 GROUND STUD RD BK RD WH BL OR Y5 GND RD 3 BL 1 BK OR DRIVE FORWARD GROUND STUD QD3 BK 7 RD/BLK W4 PC BOARD 11 12 RD BK 8 BK EN4 WH GN/YL 10 RD 12V DC OUTPUT U10 BN BL 12V DC OUTPUT 2 BL POWER TO PLATFORM GFCI RECEPTACLE BK LED 67 FOOTPAD INTERLOCK OR SW22 FORWARD/ REVERSE SWITCH BN BN RD GN/YL 6 STEER HANDLE CONTROLS N.O. *N17 NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. 5 POWER WHEEL ASSIST (OPTION) WH 4 LED 66 LEVEL INTERLOCK L7 DC MODEL: LOW BATTERY INDICATOR 3 LED 67 FOOTPAD INTERLOCK LOW BATTERY INDICATOR FOR AUXILIARY LOWERING L66 L66 L5 SW12 DOWN 16.0V DC INPUT 3 OR BK RD W3 CENTER TAP INPUT 12V DC POWER INPUT 16.0V DC INPUT NEGATIVE 12V DC AUX. INPUT POSITIVE 12V DC AUX. INPUT LED 66 LEVEL INTERLOCK 2 WH PLATFORM UP/DOWN 1 P1 RD GROUND CONTROL BOX BK WH N.C. CONTROL ACTIVATE SW11 BN EMERGENCY STOP 2 + PLATFORM CONTROL BOX B1 B WH EN2 BK 3 RD 4 BK BK EN1 WH BK RD/BLK RD PLATFORM MODE MOTOR CONTACTOR LEVEL SENSOR PCB S7 TILT SENSOR 8 M5 F11 175 AMP FUSE NON U.S. PLUGS MOTOR GN/YL WH Y30 N.O. DUMP VALVE Part No. 38139 ES0072_H Genie AWP Super Series and Genie IWP Super Series 7 - 30 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models (after serial number IWP07-7065) ABBREVIATION LEGEND Item Description B1 Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls P3 = Emergency Stop button at steer handle controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW21 = Direction — reversing safety switch SW22 = Forward/Reverse switch SW24 = Lift enable Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y5 = Drive forward Y6 = Drive reverse Y7 = Platform down Y30 = Normally open dump valve Y32 = Function solenoid D5 EN GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK GN GN/YL OR RD WH YL Description Blue Black Green Green/Yellow Orange Red White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models with Power Assist J I H G F E D BL BK BK RD 1 KS1 GROUND/ PLATFORM BK 2 W3 + LEVELING INDICATORS RD 3 LED 14 12V DC INPUT 4 LED 12 12V DC INPUT 5 L5 LED 13 12V DC INPUT 6 POWER INDICATOR L14 L12 N.O. - LED 15 12V DC INPUT 7 L6 12V DC OUTPUT 8 12V DC OUTPUT 9 INDICATOR FOR BK L15 L13 AUXILIARY LOWERING B4 12V DC OUTPUT 9A GROUND 10 12V DC MOTOR SOLENOID OUTPUT 11 8 AA BATTERIES 1 SECOND TIME DELAY 12V DC OUTPUT 12 L7 SW12 12V DC UP SIGNAL INPUT 13 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN BK WH DRIVE FORWARD WH DRIVE FUNCTION 2 12V DC POWER INPUT NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT BK WH SW22 OR FORWARD/ REVERSE SWITCH BL RD RD RD TILT SENSOR OR PC BOARD BL WT OR BL GN + + - - GN/YL POWER GN/YL INPUT PLUG WH BK D5 POWER SUPPLY AC SW18 2 BL BK 1 WH SW17 WH RD WH 6 TO PLATFORM 7 LS1 PLATFORM EXTENTION OR WH WH BK M5 CHARGE BATTERY MOTOR BK BK RD RD GN/YL OR BK 3 OR PLATFORM OUTREACH OPTION RD B2 BATTERY 12V DC YL BK B2 BATTERY 12V DC 5 BK WH BK 7 N.O. PLATFORM DOWN 4 GN YL 6 BK BK 4 Y7 WH RD BL 3 5 BK BK OR WH WH GND BK 2 WH 1 GN/YL RD 110V AC / 220V AC BK GND WH 7 TO PLATFORM GROUND STUD GN/YL BK WH GROUND STUD RD RD OR 6 BL 2 6 POWER UNIT QUICK DISCONNECT A 1 WH OR 3 WT 4 5 7 RD BK BK 3 GN/YL 2 STRAIN RELIEF TO MOTOR RD WH QD3 1 OR POWER SUPPLY AC BL RD D5 WH BK WH QD7 POWER INPUT PLUG BK WH BL NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. POWER TO PLATFORM GFCI RECEPTACLE EN2 UP BK DOWN 6 WH 4 GROUND CONTROL BOX *N17 EN4 BL GND GROUND STUD 7 OR GROUND STUD RD TERMINAL STRIP BK TO BASE WH QUICK DISCONNECT B BK GND BK PLATFORM UP/DOWN SWITCH RD QD4 GN/YL SW11 RD OR 4 N.C. BK RD S7 RD ACTIVATE SWITCH Y6 3 RD W6 PLATFORM CONTROL SW8 CONTROL BOX BK RD P2 EN1 2 Y32 WH W4 U10 WH BK RD EMERGENCY STOP WH DRIVE REVERSE BK BK Y5 RD BL 3 BK 1 1 SW21 EMERGENCY DIRECTION - REVERSING STOP SAFETY SWITCH (OPTION) BK N.C. N.O. P3 BK BK A DRIVE MANIFOLD GN/YL EMERGENCY STOP BL B STEER HANDLE CONTROLS P1 BK C GN/YL K OR L WH M OR N TO BASE WH QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE BK Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 31 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models with Power Assist ABBREVIATION LEGEND Item Description B1 Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle 15A fuse Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls P3 = Emergency Stop button at steer handle controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW21 = Direction — reversing safety switch SW22 = Forward/Reverse switch SW24 = Lift enable Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y5 = Drive forward Y6 = Drive reverse Y7 = Platform down Y30 = Normally open dump valve Y32 = Function solenoid D5 EN F1 GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK GN GN/YL OR RD WH YL Description Blue Black Green Green/Yellow Orange Red White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models with Power Assist (Directional Valve Coils Powering Function Solenoid) K J I H G F E D BK BK BL BK BK N.C. + BK L14 L12 BK L15 L13 B4 LED 12 12V DC INPUT 5 LED 13 12V DC INPUT 6 LED 15 12V DC INPUT 7 L6 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 1 SECOND TIME DELAY 12V DC OUTPUT 12 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN U10 12V DC UP SIGNAL INPUT 13 PC BOARD BL WH SW22 OR OR FORWARD/ REVERSE SWITCH BL RD DRIVE FUNCTION WH RD S7 TILT SENSOR OR W4 WH 5 OR 3 BL 2 WH 1 6 GN 5 Y7 WH RD BK N.O. PLATFORM DOWN 5 YL RD 4 GN 3 OR SW18 2 BL BK 1 WH SW17 BK WH RD 6 WH BK BL + + WH GND - GN/YL - BK BK POWER INPUT PLUG D5 GN/YL WH POWER SUPPLY AC CHARGE BATTERY MOTOR BK BK RD BK BK M5 GN/YL OR RD B2 BATTERY 12V DC RD GN/YL B2 BATTERY 12V DC WH WH YL 7 BK 6 BL 4 WH 3 WH BK OR 2 LS1 PLATFORM EXTENTION OR OR 7 OR 6 7 OR WH WT 4 BK BK 3 GN/YL 2 TO PLATFORM POWER UNIT RD GN/YL OR BK WH BK GND RD (OPTION) STRAIN RELIEF QUICK DISCONNECT A RD GROUND STUD GN/YL BK GROUND STUD RD BK PLATFORM OUTREACH TO MOTOR RD WH QD3 1 OR POWER SUPPLY AC WH BK WH D5 BL RD BK WH BL QD7 POWER INPUT PLUG 1 110V AC / 220V AC EN2 UP 6 WH 4 GROUND CONTROL BOX TO PLATFORM WH RD OR DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. POWER TO PLATFORM GFCI RECEPTACLE BL GND GROUND STUD *N17 EN4 RD 7 TO BASE GND GROUND STUD TERMINAL STRIP BK 7 QUICK DISCONNECT B BK WT BK RD QD4 BK PLATFORM UP/DOWN SWITCH OR 3 RD W6 GN/YL SW11 Y6 4 CONTROL ACTIVATE SWITCH BK BK RD RD N.C. PLATFORM CONTROL BOX SW8 2 Y32 WH P2 WH WH BK RD EMERGENCY STOP EN1 DRIVE REVERSE BK BK Y5 RD BL 3 LED 14 12V DC INPUT 4 LOW BATTERY INDICATOR FOR AUXILIARY LOWERING L7 SW12 DRIVE FORWARD 2 12V DC MOTOR SOLENOID OUTPUT 11 8 AA BATTERIES N.O. W3 POWER INDICATOR BK N.O. BL 3 L5 RD BK 2 12V DC POWER INPUT NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT LEVELING INDICATORS KS1 GROUND/ PLATFORM DRIVE MANIFOLD BK WH BK 1 A 1 EMERGENCY DIRECTION - REVERSING STOP SAFETY SWITCH (OPTION) BK RD 1 B STEER HANDLE CONTROLS P3 SW21 P1 EMERGENCY STOP C GN/YL L WH M OR N TO BASE WH QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE BK Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 32 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC Models with Power Assist (Directional Valve Coils Powering Function Solenoid) ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle 15A fuse Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW24 = Lift enable Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN F1 GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK GN GN/YL OR RD WH YL Description Blue Black Green Green/Yellow Orange Red White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC TUV Models M L K J I H G F E D C B A 1 P1 EMERGENCY STOP BK BK BL BK BK RD BK N.C. 1 KS1 GROUND/ PLATFORM BK 2 + RD 2 3 LED 1 12V DC INPUT 4 LED 2 12V DC INPUT 5 L5 LED 3 12V DC INPUT 6 POWER INDICATOR L14 L12 BK L15 L13 B4 LED 4 12V DC INPUT 7 L6 12V DC OUTPUT 8 INDICATOR FOR AUXILIARY LOWERING 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 12V DC MOTOR SOLENOID OUTPUT 11 8 AA BATTERIES 1 SECOND TIME DELAY 12V DC OUTPUT 12 L7 SW12 12V DC UP SIGNAL INPUT 13 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN 2 WH OR BL RD BK RD WH 3 RD S7 TILT SENSOR OR W4 U10 PC BOARD BL P2 W6 TERMINAL STRIP RD QD4 EN2 BL POWER TO PLATFORM GFCI RECEPTACLE 110V AC / 220V AC WH GND GROUND STUD GN/YL BK GN/YL BK + B2 BATTERY 12V DC POWER GN/YL INPUT PLUG WH - BK QD1(-) D5 POWER SUPPLY AC SW17 WH WH 6 PLATFORM OUTREACH OPTION TO PLATFORM 7 LS1 WH WH BK F1 CHARGE BATTERY M5 15 AMP BK MOTOR BK RD RD BK PLATFORM EXTENTION OR GN/YL OR BK BK 1 WH BK RD QD1(+) OR SW18 2 BL YL RD 3 OR BK WH 7 YL 4 GN BK 6 5 DOWN BK BL 4 N.O. Y7 PLATFORM WH RD WH 3 5 BK OR 2 WH 1 OR WH BK TO PLATFORM WH GN GND OR 7 BL 2 6 POWER UNIT QUICK DISCONNECT A 1 EN4 BK GROUND STUD WH 6 5 OR 3 WT 4 6 7 RD GN/YL BK BK 3 GN/YL 2 STRAIN RELIEF TO MOTOR RD OR QD3 1 BL POWER SUPPLY AC WH D5 WH BK QD7 POWER INPUT PLUG RD BL NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. WH *N17 BK BK PLATFORM BK UP/DOWN DOWN SWITCH WH UP 7 WH 4 GROUND CONTROL BOX GN/YL SW11 BL GND GROUND STUD WT BK GROUND STUD RD TO BASE GND PLATFORM CONTROL SW8 CONTROL BOX ACTIVATE SWITCH BK WH QUICK DISCONNECT B N.C. OR EN1 BK WH 4 EMERGENCY STOP WH RD OR RD BL 1 LEVELING INDICATORS N.O. N.O. W3 12V DC POWER INPUT NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT BK BL 3 GN/YL BK OR N TO BASE WH QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 33 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC TUV Models ABBREVIATION LEGEND Item Description B Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle 15A fuse Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW24 = Lift enable Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve D5 EN F1 GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK GN GN/YL OR RD WH YL Description Blue Black Green Green/Yellow Orange Red White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC TUV Models with Outreach M L K J I H G F E D C B A 1 P1 RD EMERGENCY STOP RD RD BK BK BK BK N.C. RD 1 KS1 PLATFORM RD RD BK BK 2 3 W3 + LEVELING INDICATORS - GROUND BK BL BK L15 L13 B4 RD N.O. LED 3 12V DC INPUT 6 LED 4 12V DC INPUT 7 L6 12V DC OUTPUT 8 INDICATOR FOR AUXILIARY LOWERING 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 1 SECOND TIME DELAY 12V DC OUTPUT 12 L7 12V DC UP SIGNAL INPUT 13 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN N.O. LED 2 12V DC INPUT 5 12V DC MOTOR SOLENOID OUTPUT 11 8 AA BATTERIES SW12 WH OR BL RD BK RD 3 WH RD S7 TILT SENSOR OR W4 U10 RD PC BOARD BL BK OR WH BK GN 4 BL BL 3 LED 1 12V DC INPUT 4 L5 L14 L12 2 2 POWER INDICATOR KS1 BK 1 12V DC POWER INPUT NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT N.O. P2 W6 EMERGENCY STOP QD4 BL 2 WH 1 5 BK Y7 WH RD BK N.O. PLATFORM DOWN 5 YL 4 GN 3 OR SW18 2 BL BK 1 WH SW17 BK WH WH 6 BL WH GND GN/YL BK B2 BATTERY 12V DC + BK POWER GN/YL INPUT PLUG WH - BK D5 POWER SUPPLY AC CHARGE BATTERY M5 BK MOTOR BK RD GN/YL BK BK F1 15 AMP RD GN/YL QD1(+) OR WH WH YL 7 BK 6 BL 4 WH 3 WH BK GN/YL 2 LS1 PLATFORM EXTENTION OR OR 7 7 OR 6 OR WH OR BK 4 TO PLATFORM WH OR RD POWER UNIT WT RD 3 PLATFORM OUTREACH OPTION RD BK OR 2 STRAIN RELIEF QUICK DISCONNECT A RD BK OR 3 TO MOTOR GN/YL WH QD3 1 BL POWER SUPPLY AC WH BK WH BK WH BK RD D5 1 110V AC / 220V AC EN2 QD7 POWER INPUT PLUG TO PLATFORM GROUND STUD GN/YL 5 7 6 BK BL NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. POWER TO PLATFORM GFCI RECEPTACLE 6 GROUND STUD UP *N17 WH 7 WH 4 GROUND CONTROL BOX PLATFORM BK UP/DOWN DOWN SWITCH EN4 BL GND GROUND STUD GN/YL SW11 RD WT BK WH GROUND STUD TO BASE GND PLATFORM SW8 CONTROL CONTROL ACTIVATE BOX SWITCH BK QUICK DISCONNECT B N.C. EN1 GND TERMINAL STRIP RD WH OR N TO BASE WH QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE QD1(-) Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 34 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC TUV Models with Outreach ABBREVIATION LEGEND Item Description B1 Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle 15A fuse Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls P3 = Emergency Stop button at steer handle controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW21 = Direction — reversing safety switch SW22 = Forward/Reverse switch SW24 = Lift enable Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y5 = Drive forward Y6 = Drive reverse Y7 = Platform down Y30 = Normally open dump valve Y32 = Function solenoid D5 EN F1 GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK GN GN/YL OR RD WH YL Description Blue Black Green Green/Yellow Orange Red White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC TUV Models with Power Assist K J I H G F E D EMERGENCY STOP BK BK BL BK BK 2 + LEVELING INDICATORS RD BK 3 LED 1 12V DC INPUT 4 LED 2 12V DC INPUT 5 L5 LED 3 12V DC INPUT 6 L14 L12 BK L15 L13 B4 LED 4 12V DC INPUT 7 L6 12V DC OUTPUT 8 LOW BATTERY INDICATOR FOR AUXILIARY LOWERING 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 12V DC MOTOR SOLENOID OUTPUT 11 8 AA BATTERIES 1 SECOND TIME DELAY 12V DC OUTPUT 12 L7 SW12 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN U10 12V DC UP SIGNAL INPUT 13 PC BOARD BL WH OR BK WH SW22 WH RD DRIVE FUNCTION RD BK TILT SENSOR OR W4 WH BK GN BL GROUND STUD OR 3 GROUND CONTROL BOX WT 5 WH 4 EN2 UP 6 BL 2 WH 1 6 5 GND TERMINAL STRIP BK 7 TO BASE RD GND GROUND STUD RD RD BK N.O. Y7 PLATFORM WH RD 5 DOWN BK YL 4 GN 3 OR SW18 2 BL BK 1 WH SW17 BK WH RD 6 WH BK BL + + GND - GN/YL POWER GN/YL INPUT PLUG - BK D5 POWER SUPPLY AC CHARGE BATTERY M5 BK MOTOR BK RD GN/YL BK BK F1 15 AMP GN/YL OR BK WH WH GROUND STUD GN/YL RD B2 BATTERY 12V DC RD YL B2 BATTERY 12V DC WH WH BK 7 BL 6 WH 4 OR 3 LS1 GN/YL OR 2 7 PLATFORM EXTENTION OR WH BK TO PLATFORM OR 7 OR 6 OR WH QUICK DISCONNECT A RD WH POWER UNIT WT 4 PLATFORM OUTREACH OPTION RD BK BK 3 GN/YL 2 STRAIN RELIEF TO MOTOR RD WH QD3 1 OR POWER SUPPLY AC WH BK WH D5 BL RD BK WH BL QD7 POWER INPUT PLUG 1 BK RD 7 QUICK DISCONNECT B WH TO PLATFORM 110V AC / 220V AC BK DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. POWER TO PLATFORM GFCI RECEPTACLE RD OR RD BK GND *N17 EN4 GN/YL 4 GROUND STUD BK PLATFORM UP/DOWN SWITCH Y6 S7 QD4 GN/YL SW11 BK 3 RD N.C. BK 2 Y32 RD RD ACTIVATE SWITCH WH WH W6 PLATFORM CONTROL SW8 BOX CONTROL Y5 BK RD P2 EN1 DRIVE REVERSE BK BK EMERGENCY STOP WH DRIVE FORWARD GN/YL FORWARD/ REVERSE SWITCH BL 1 SW21 2 POWER INDICATOR BK N.O. BL W3 12V DC POWER INPUT NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT KS1 GROUND/ PLATFORM 3 1 A DRIVE MANIFOLD EMERGENCY DIRECTION - REVERSING STOP SAFETY SWITCH (OPTION) BK RD 1 BK P3 BK N.C. N.O. B STEER HANDLE CONTROLS P1 BL C GN/YL L WH M OR N TO BASE WH QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE BK Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 35 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC TUV Models with Power Assist ABBREVIATION LEGEND Item Description B1 Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle 15A fuse Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls P3 = Emergency Stop button at steer handle controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW21 = Direction — reversing safety switch SW22 = Forward/Reverse switch SW24 = Lift enable Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y5 = Drive forward Y6 = Drive reverse Y7 = Platform down Y30 = Normally open dump valve Y32 = Function solenoid D5 EN F1 GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK GN GN/YL OR RD WH YL Description Blue Black Green Green/Yellow Orange Red White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC TUV Models with Power Assist and Outreach L K J I H P1 RD BK BK P3 2 3 W3 LEVELING INDICATORS L14 L12 - GROUND BK BL RD BK L15 L13 B4 N.O. LED 4 12V DC INPUT 7 L6 12V DC OUTPUT 8 INDICATOR FOR AUXILIARY LOWERING 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 1 SECOND TIME DELAY 12V DC OUTPUT 12 L7 12V DC UP SIGNAL INPUT 13 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN N.O. LED 3 12V DC INPUT 6 12V DC MOTOR SOLENOID OUTPUT 11 8 AA BATTERIES SW12 DRIVE FORWARD BK WH WH WH SW22 OR OR FORWARD/ REVERSE SWITCH BL RD DRIVE FUNCTION RD DRIVE REVERSE BK BK WH 2 Y32 BK Y6 OR BK RD RD 3 WH RD S7 TILT SENSOR OR W4 U10 Y5 PC BOARD BL RD BK OR WH BK GN 4 BL BL LED 2 12V DC INPUT 5 POWER INDICATOR KS1 BK 3 LED 1 12V DC INPUT 4 1 DRIVE MANIFOLD 2 L5 N.O. A SW21 BK 1 12V DC POWER INPUT NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT + B EMERGENCY DIRECTION - REVERSING STOP SAFETY SWITCH (OPTION) PLATFORM BK C STEER HANDLE CONTROLS 1 KS1 RD D BK RD BK E BK N.C. RD F RD EMERGENCY STOP RD G GN/YL M P2 W6 EMERGENCY STOP RD QD4 BL + + GROUND STUD GN/YL - BK D5 POWER SUPPLY AC WH RD 6 WH PLATFORM OUTREACH OPTION TO PLATFORM 7 LS1 WH WH BK F1 CHARGE BATTERY M5 15 AMP BK MOTOR BK RD RD BK PLATFORM EXTENTION OR GN/YL OR POWER GN/YL INPUT PLUG WH - GN/YL BK SW17 BK RD B2 BATTERY 12V DC BK 1 WH YL B2 BATTERY 12V DC SW18 2 BL BK 7 3 OR BL 6 WH GND BK 4 YL GN/YL OR 3 5 4 GN WH RD 2 BK BK WH BK N.O. Y7 PLATFORM DOWN WH RD OR 7 RD BK OR 6 5 GND GROUND STUD RD WH 4 WH 1 WT BK 3 BL 2 OR WH GN/YL 1 WH OR 3 6 RD QUICK DISCONNECT A TO PLATFORM 110V AC / 220V AC WH BK RD BK OR 2 5 7 POWER UNIT TO MOTOR GN/YL QD3 1 BL POWER SUPPLY AC WH D5 STRAIN RELIEF BK BK WH QD7 POWER INPUT PLUG RD BL NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. WH *N17 POWER TO PLATFORM GFCI RECEPTACLE EN2 UP 6 WH 4 GROUND CONTROL BOX PLATFORM BK UP/DOWN DOWN SWITCH EN4 BL GND GROUND STUD GN/YL SW11 RD WT BK WH GROUND STUD TERMINAL STRIP BK 7 TO BASE GND PLATFORM CONTROL SW8 CONTROL BOX ACTIVATE SWITCH BK QUICK DISCONNECT B N.C. EN1 RD OR WH OR N TO BASE WH QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE BK Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 36 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC TUV Models with Power Assist and Outreach ABBREVIATION LEGEND Item Description B1 Battery B2 = 12V DC B4 = 8 AA batteries Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle 15A fuse Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls P3 = Emergency Stop button at steer handle controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW21 = Direction — reversing safety switch SW22 = Forward/Reverse switch SW24 = Lift enable Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y5 = Drive forward Y6 = Drive reverse Y7 = Platform down Y30 = Normally open dump valve Y32 = Function solenoid D5 EN F1 GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK GN GN/YL OR RD WH YL Description Blue Black Green Green/Yellow Orange Red White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC TUV Models with Power Assist (Directional Valve Coils Powering Function Solenoid) L K J I H P1 F E D P3 BK RD N.C. RD 1 KS1 PLATFORM RD RD BK BK 2 3 W3 LEVELING INDICATORS - GROUND BK BK BL RD BK L15 L13 B4 N.O. LED 3 12V DC INPUT 6 LED 4 12V DC INPUT 7 L6 12V DC OUTPUT 8 INDICATOR FOR AUXILIARY LOWERING 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 1 SECOND TIME DELAY 12V DC OUTPUT 12 L7 12V DC UP SIGNAL INPUT 13 DC MODEL: LOW BATTERY INDICATOR AUXILIARY DOWN N.O. LED 2 12V DC INPUT 5 12V DC MOTOR SOLENOID OUTPUT 11 8 AA BATTERIES SW12 BK WH FORWARD U10 WH WH SW22 OR OR FORWARD/ REVERSE SWITCH BL RD DRIVE FUNCTION RD DRIVE REVERSE BK BK WH 2 Y32 BK Y6 OR BK RD RD 3 WH RD S7 TILT SENSOR OR W4 PC BOARD BL RD BK OR WH BK GN 4 BL BL 3 LED 1 12V DC INPUT 4 POWER INDICATOR L14 L12 DRIVE MANIFOLD Y5 DRIVE 2 L5 N.O. KS1 A 1 DIRECTION - REVERSING SAFETY SWITCH BK 1 12V DC POWER INPUT NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT + B SW21 EMERGENCY STOP (OPTION) BK BK BK C STEER HANDLE CONTROLS RD EMERGENCY STOP RD G GN/YL M P2 W6 EMERGENCY STOP RD QD4 BL + GROUND STUD GN/YL + GN/YL BK POWER GN/YL INPUT PLUG - BK D5 POWER SUPPLY AC WH RD 6 WH TO PLATFORM 7 LS1 WH WH BK F1 CHARGE BATTERY M5 15 AMP BK MOTOR BK RD RD BK PLATFORM EXTENTION OR GN/YL OR RD B2 BATTERY 12V DC WH - PLATFORM OUTREACH OPTION YL B2 BATTERY 12V DC SW17 BK 7 BK 1 WH BL 6 WH GND BK 4 SW18 2 BL GN/YL OR 3 RD 3 OR WH RD 2 YL 4 GN BK WH BK 5 DOWN BK OR 7 N.O. Y7 PLATFORM WH RD OR 6 RD BK WH 4 5 GND GROUND STUD RD BK WT BK 3 BL 2 WH 1 OR WH GN/YL 1 WH OR 3 6 RD QUICK DISCONNECT A TO PLATFORM 110V AC / 220V AC WH BK RD BK OR 2 5 7 POWER UNIT TO MOTOR GN/YL QD3 1 BL POWER SUPPLY AC WH D5 STRAIN RELIEF BK BK WH QD7 POWER INPUT PLUG RD BL NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. WH *N17 POWER TO PLATFORM GFCI RECEPTACLE EN2 UP 6 WH 4 GROUND CONTROL BOX PLATFORM BK UP/DOWN DOWN SWITCH EN4 BL GND GROUND STUD GN/YL SW11 RD WT BK WH GROUND STUD TERMINAL STRIP BK 7 TO BASE GND PLATFORM CONTROL SW8 CONTROL BOX ACTIVATE SWITCH BK QUICK DISCONNECT B N.C. EN1 RD OR WH OR N TO BASE WH QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE BK Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 37 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series DC TUV Models with Power Assist (Directional Valve Coils Powering Function Solenoid) ABBREVIATION LEGEND Item Description B Battery B4 = 8 AA batteries 15A circuit breaker Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW24 = Lift enable Electronic component U9 = Transformer U10 = PC board U12 = Thermal device Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve CB1 D5 EN GND KS1 L LS1 M5 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BN BK GN GN/YL OR RD RD/YL WH WH/BK YL Description Blue Brown Black Green Green/Yellow Orange Red Red/Yellow White White/Black Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC Models (from serial number 4096-105 to 4096-285) M L K J I H G F E D C B A 1 U12 P1 EMERGENCY STOP BK TRANSFORMER BK YL 1 KS1 BK L15 L13 B4 16V AC INPUT 1 CENTER TAP INPUT 2 16V AC INPUT 3 RD RD OR LED13 12V DC INPUT 6 BL RD 12V DC OUTPUT 9 RD 12V DC OUTPUT 9A RD AUXILIARY DOWN S7 BK 1 SECOND TIME DELAY 12V DC OUTPUT 12 TILT SENSOR OR 12V DC UP SIGNAL INPUT 13 DC MODEL: LOW BATTERY INDICATOR 3 GN/YL GROUND 10 L7 SW12 2 WH BK 12V DC OUTPUT 8 12V DC MOTOR RELAY OUTPUT 11 8 AA BATTERIES BN RD LED15 12V DC INPUT 7 INDICATOR FOR AUXILIARY LOWERING BL WH LED12 12V DC INPUT 5 L6 WH RD/YL LED14 12V DC INPUT 4 L5 L14 L12 - BK W4 U10 PC BOARD RD RD BK OR WH BK GN WH N.O. W3 POWER INDICATOR BK WH 3 LEVELING INDICATORS BK N.O. 2 NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT + GROUND/ PLATFORM THERMAL DEVICE YL U9 BK RD N.C. 4 P2 W6 EMERGENCY STOP QD4 GND PLATFORM CONTROL BOX GROUND STUD SW8 BK WH 7 6 5 GN/YL 4 OR 3 EN2 CB1 15 AMP BL 2 GROUND CONTROL BOX WT UP WH 1 7 6 STRAIN RELIEF SW18 2 GN BK 1 WH SW17 GN GN 6 WH GND BK GND GN/YL GROUND STUD 7 BK GN/YL GN/YL 8 TO BASE BK GN/YL BL RD YL BK BK M5 RD BL WH GN/YL WH WH WH 7 OR 6 OR 4 BK 3 GN/YL 2 TO PLATFORM LS1 MOTOR BK 4 GN/YL 3 OR PLATFORM EXTENTION QUICK DISCONNECT A OR 110V AC / 220V AC 5 WH/BK WH 7 BK 6 RD BK 4 GN/YL RD 3 POWER UNIT RD GROUND STUD GN/YL BK N.O. PLATFORM DOWN BK TO PLATFORM POWER TO PLATFORM GFCI RECEPTACLE Y7 WH GN BK BK RD GN/YL BK OR 2 GN/YL WH QD3 1 WH RD BL D5 POWER SUPPLY AC 1 WH BK PLATFORM OUTREACH OPTION TO MOTOR BK BK WH QD7 POWER INPUT PLUG EN4 5 GND GROUND STUD DOWN GN/YL PLATFORM UP/DOWN SWITCH RD GND GROUND STUD CONTROL ACTIVATE SWITCH BK SW11 BK GN/YL TO BASE N.C. QUICK DISCONNECT B EN1 TERMINAL STRIP RD WH OR N QUICK DISCONNECT A Y30 TO PLATFORM QD3 N.O. DUMP VALVE BK Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 38 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC Models (from serial number 4096-105 to 4096-285) ABBREVIATION LEGEND Item Description B Battery B4 = 8 AA batteries 15A circuit breaker Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW24 = Lift enable Electronic component U9 = Transformer U10 = PC board U12 = Thermal device Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve CB1 D5 EN GND KS1 L LS1 M5 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK BN GN GN/YL OR RD RD/YL WH WH/BK YL Description Blue Black Brown Green Green/Yellow Orange Red Red/Yellow White White/Black Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC Models (from serial number 4096-286 to 4096-355) M L K J I H G F EMERGENCY STOP BK E D C B A 1 U12 P1 RD THERMAL DEVICE YL U9 BK RD TRANSFORMER BK BK YL N.C. 1 RD KS1 GROUND/ PLATFORM 2 3 W3 + N.O. BK N.O. L14 L12 - BK BK L15 L13 B4 BK 12V DC OUTPUT 8 RD 12V DC OUTPUT 9 RD 12V DC OUTPUT 9A GN/YL GROUND 10 AUXILIARY DOWN U10 S7 BK TILT SENSOR OR 12V DC UP SIGNAL INPUT 13 DC MODEL: LOW BATTERY INDICATOR 3 RD 1 SECOND TIME DELAY 12V DC OUTPUT 12 L7 SW12 W4 PC BOARD RD RD BK OR WH BK GN WH N.O. RD LED15 12V DC INPUT 7 12V DC MOTOR RELAY OUTPUT 11 8 AA BATTERIES WH BL LED13 12V DC INPUT 6 INDICATOR FOR AUXILIARY LOWERING 2 WH OR LED12 12V DC INPUT 5 L6 BN WH LED14 12V DC INPUT 4 POWER INDICATOR BL RD 16V AC INPUT 3 L5 WH RD/YL CENTER TAP INPUT 2 LEVELING INDICATORS BK RD 16V AC INPUT 1 NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT RD BK 4 P2 W6 EMERGENCY STOP QD4 RD BK RD M5 OR WH GN/YL WH WH BK MOTOR EN4 POWER TO PLATFORM GFCI RECEPTACLE 110V AC / 220V AC WH WH GND GROUND STUD GN/YL BK BK GND GN/YL GROUND STUD RD TO BASE BK GN/YL BL RD BK 7 YL 6 GN 6 7 BK 4 GN TO PLATFORM BL 3 SW17 PLATFORM EXTENTION TO PLATFORM 2 BK 1 WH LS1 QUICK DISCONNECT A 1 SW18 2 GN WH 7 3 OR BK POWER UNIT BK 6 RD BK 4 5 BK STRAIN RELIEF GN/YL RD 3 BK OR 2 WH/BK N.O. PLATFORM DOWN 4 GN/YL PLATFORM OUTREACH OPTION TO MOTOR GN/YL WH QD3 1 WH POWER SUPPLY AC GN/YL BK WH GN/YL BK RD BL D5 WH 1 BK GN/YL UP DOWN BL 2 5 Y7 WH GN GN/YL WT QD7 OR 3 EN2 GROUND CONTROL BOX CB1 15 AMP POWER INPUT PLUG 5 GN/YL 4 6 BK OR BK PLATFORM UP/DOWN SWITCH 6 7 OR CONTROL ACTIVATE SWITCH BK WH GND GROUND STUD GN/YL SW8 7 GND GROUND STUD WH GROUND STUD RD TO BASE GND PLATFORM CONTROL BOX SW11 BK GN/YL QUICK DISCONNECT B N.C. BK EN1 TERMINAL STRIP RD WH OR N QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE BK Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 39 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC Models (from serial number 4096-286 to 4096-355) ABBREVIATION LEGEND Item Description B Battery B4 = 8 AA batteries 15A circuit breaker Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW24 = Lift enable Electronic component U9 = Transformer U10 = PC board U12 = Thermal device Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve CB1 D5 EN GND KS1 L LS1 M5 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK BN GN GN/YL OR RD RD/YL WH WH/BK YL Description Blue Black Brown Green Green/Yellow Orange Red Red/Yellow White White/Black Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC Models (from serial number 4096-356 to IWP07-7065) N M L K J I H G F E D C B A 1 2 3 4 5 6 7 8 Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 40 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC Models (from serial number 4096-356 to IWP07-7065) ABBREVIATION LEGEND Item Description B Battery B4 = 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Warning light Ground Descent alarm Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L66 = Level sensor interlock L67 = Footpad interlock Hydraulic power unit Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units with out plug: WH and BK wires replace BL and BN wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side Electronic component U9 = Transformer U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve CB4 D5 EN FB2 GND H4 KS1 L M5 *N N.C. N.O. P PR QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK RD/YL WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC Models (from serial number IWP07-7066 to IWP07-57594) N M L K J I H G F E D C B A RD/BLK 1 RD KEY SWITCH P2 BK 1 P1 EMERGENCY STOP BK CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT RIGHT 2 2 3 L66 L66 N.C. LOW BATTERY INDICATOR FOR AUXILIARY LOWERING L7 MODEL: L67 L67 DC LOW BATTERY WH INDICATOR L5 SW12 RD YL RD/YL BK BN BL RD WH 2 WH 4 OR 5 LED 14 REAR LEFT 6 LED 12 FRONT LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A BL RD BK RD/BLK GROUND 10 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 WHT 3 OR BK OR W4 N.O. BN BL 4 OR WH GND RD OR WH PR4 BK GROUND STUD J BOX RD EN4 POWER TO PLATFORM GFCI RECEPTACLE 8A CIRCUIT BREAKER 220V AC MODELS 15A CIRCUIT BREAKER 110V AC MODELS CB4 QD4 WH WH BL WH 7 BK RD 6 GN/YL Y7 BK N.O. PLATFORM DOWN GN/YL 6 RD BN 5 5 WH 4 4 YL GN/YL WH OR 3 3 OR WH BL 2 2 RD WH 1 1 BL WH BL WH OR 5 WH BK BK BK GN/YL WH BK 7 WH BK SW18 6 SW17 WH STRAIN RELIEF DESCENT ALARM NC GND GN/YL WH GN/YL H4 BK WH GROUND STUD LEVEL SENSOR PCB S7 7 TILT SENSOR TO MOTOR GN/YL RD BL OR WH YL 1 3 BK BL *N7 MOTOR 110V AC MOTOR DETAIL 2 4 GND OR YL EN6 WH 1 3 BK J-BOX M5 Y30 N.O. DUMP VALVE WH M5 N.O. DUMP VALVE WH J-BOX GROUND SCREW Y30 GN/YL OPTIONAL WARNING LIGHT AND DESCENT ALARM EN5 WH WARNING LIGHT BK GROUND SCREW BK GN/YL FB2 BK BK D5 POWER SUPPLY AC BK GROUND STUD TO PLUG WH RD OR 7 GN/YL 7 6 BL 6 4 5 WHT 4 5 1 2 3 YL BK WH GN/YL BL BN BN RD RD BK GN/YL OR BL WHT GN/YL GROUND STUD 1 2 3 110V AC TERMINAL STRIP DETAIL TERMINAL STRIP WH STRAIN RELIEF QD3 *N7 W5 UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL AND BN WIRES. BN WH *N27 WH BK BK WH BL OR WH BK WH BN BK *N17 BK 3 LED 15 REAR RIGHT PC BOARD RD AUXILIARY DOWN GN/YL TRANSFORMER RD UP SIGNAL OUTPUT U10 POWER INDICATOR UP DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. L6 LEVELING INDICATOR INPUTS BL BK B4 8 AA BATTERIES YL BK 1 LEVELING INDICATORS RD RD RD W3 16.0V DC INPUT FOR 240 V OPERATION JUMPER BROWN TO WHITE THROUGH TERMINAL STRIP AND LEAVE BLACK UNCONNECTED AS SHOWN U9 BK 1 N.C. SW8 PLATFORM UP/DOWN 2 BASE MODE RD WH CONTROL ACTIVATE SW11 BK B EMERGENCY STOP GROUND CONTROL BOX BK + PLATFORM CONTROL BOX B1 BN EN1 EN2 3 RD 4 BK BK - RD/BLK KS1 PLATFORM MODE 8 *N10 MOTOR 220 V AC MOTOR DETAIL 2 4 GND ES0073_G Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 41 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC Models (from serial number IWP07-7066 to IWP07-57594) ABBREVIATION LEGEND Item Description B Battery B4 = 8 AA batteries Circuit breaker, 15A-110V / 8A-220V Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN5 = Power unit — 110V AC EN6 = Power unit — 220V AC Warning light Ground Descent alarm Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L66 = Level sensor interlock L67 = Footpad interlock Hydraulic power unit Note with description *N7 = 110V AC terminal strip detail *N8 = 110V AC motor detail *N9 = 220V AC terminal strip detail *N10 = 220V AC motor detail *N17 = Narrow platform units: WH and BK wires replace BL and OR wires *N27 = Units with out plug: WH and BK wires replace BL and BN wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Power relay PR4 = Function pump (M5) Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side Electronic component U9 = Transformer U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W5 = Terminal strip — 7 pole 14 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve CB4 D5 EN FB2 GND H4 KS1 L M5 *N N.C. N.O. P PR QD S7 SW U W Y WIRE COLOR LEGEND Color BL BK BN GN/YL OR RD RD/BK RD/YL WH YL Description Blue Black Brown Green/Yellow Orange Red Red/Black Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC Models (after serial number IWP07-57594) N M L K J I H G F E D C B A *N28 PLATFORM CONTROL BOX RD BK RD/BLK N.C. WH 1 BN BASE MODE RD WH 2 BK - EMERGENCY STOP EN1 EN2 3 RD B1 BK P2 WH PLATFORM MODE BL KEY SWITCH 1 P1 SW8 BK SW11 BK PLATFORM UP/DOWN CENTER TAP INPUT 12V DC POWER INPUT NEGATIVE 12V DC AUX. INPUT 16.0V DC INPUT POSITIVE 12V DC AUX. INPUT LED 13 FRONT LEFT 2 2 3 L67 L67 WH L5 SW12 UP RD BL WH GND RD WH 2 OR 5 6 LED 12 FRONT LEFT 7 12V DC OUTPUT 8 12V DC OUTPUT 9 12V DC OUTPUT 9A GROUND 10 UP SIGNAL OUTPUT 11 UP SIGNAL OUTPUT (DELAYED) 12 UP SIGNAL INPUT 13 BL RD BK RD/BLK BL WHT 3 OR BK OR W4 WH CB9 PR4 BK 6A CIRCUIT BREAKER 120V AC MODELS 4 OR WH GROUND STUD RD WH BK RD/YL BN BN *N17 BL YL BK BN BL WH 4 PC BOARD RD N.O. OR 3 LED 14 REAR LEFT U10 TRANSFORMER RD LED 15 REAR RIGHT L7 DC MODEL: LOW BATTERY INDICATOR POWER INDICATOR AUXILIARY DOWN LEVELING INDICATOR INPUTS LOW BATTERY INDICATOR FOR AUXILIARY LOWERING N.C. DOWN NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL(2) AND OR(3) WIRES. L6 L66 L66 8 AA BATTERIES YL BK CONTROL ACTIVATE B4 RD RD RD 1 LEVELING INDICATORS + EMERGENCY STOP W3 16.0V DC INPUT FOR 120V OPERATION JUMPER BROWN TO BLACK AND BLUE TO WHITE AS SHOWN WITH DASHED LINES (CB4 = 15A, CB9 = 6A) U9 GROUND CONTROL BOX BK KS1 1 FOR 240 V OPERATION JUMPER BROWN TO WHITE THROUGH TERMINAL STRIP AND LEAVE BLACK UNCONNECTED AS SHOWN CB4 = 8A, CB9 = 3A) WH J BOX GN/YL 3A CIRCUIT BREAKER 240V AC MODELS RD EN4 QD4 GN/YL N WH WH WH WH WH GN/YL GN/YL WH WH BN N GN/YL WH BK N W5 TERMINAL STRIP 7 7 BK RD 6 GN/YL N.O. PLATFORM DOWN GN/YL 6 RD BN 5 5 4 4 YL GN/YL WH OR 3 3 OR WH BL 2 2 RD WH 1 1 BL WH BL WH OR (N) DENOTES A NEUTRAL WIRE TO BE TAGGED WITH AN (N) SLEEVE 5 WH BK BK *N30 Y7 BK WH *N29 110V AC / 220V AC TERMINAL STRIP DETAIL WH BK SW18 6 SW17 WH OR TO PLUG GN/YL GN/YL H4 BK NC LEVEL SENSOR PCB STRAIN RELIEF DESCENT ALARM S7 7 TILT SENSOR TO MOTOR GN/YL RD BL OR WH YL 1 3 BK BL *N8 MOTOR 110V AC MOTOR DETAIL 2 4 GND OR YL EN6 WH 1 3 BK J-BOX M5 Y30 N.O. DUMP VALVE WH M5 N.O. DUMP VALVE WH J-BOX GROUND SCREW Y30 GN/YL OPTIONAL WARNING LIGHT AND DESCENT ALARM EN5 WH WARNING LIGHT BK GROUND SCREW BK BK FB2 GN/YL *N27 UNITS WITHOUT PLUG WH AND BK WIRES REPLACE BL AND BN WIRES. WH WH D5 POWER SUPPLY AC WH BK BL WH GN/YL BK RD BL BN GN/YL RD RD GN/YL 7 N BK BK GN/YL OR BL WHT 7 6 BL 6 4 5 OR 4 5 1 2 3 WHT 1 2 3 N BK BK STRAIN RELIEF QD3 WH 240V AC MODELS BK BN N BL CB4 8A CIRCUIT BREAKER WH BK 15A CIRCUIT BREAKER 120V AC MODELS GROUND STUD GN/YL POWER TO PLATFORM GFCI RECEPTACLE YL 8 *N10 MOTOR 220 V AC MOTOR DETAIL 2 4 GND ES0073_K Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 42 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC Models (after serial number IWP07-57594) ABBREVIATION LEGEND Item Description B Battery B4 = 8 AA batteries 15A circuit breaker Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle EN9 = Junction box (option) Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side Electronic component U9 = Transformer U10 = PC board U12 = Thermal device Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 7 pole 7 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve CB1 D5 EN GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BN BK GN GN/YL OR RD RD/YL WH YL Description Blue Brown Black Green Green/Yellow Orange Red Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC TUV Models with Base Mounted Junction Box M L K J I H G F E D C B A 1 U12 P1 EMERGENCY STOP BK TRANSFORMER RD BK YL 1 N.C. KS1 GROUND/ PLATFORM RD RD BK BK N.O. W3 L15 L13 B4 RD LED15 12V DC INPUT 7 BK 12V DC OUTPUT 8 RD 12V DC OUTPUT 9 12V DC OUTPUT 9A AUXILIARY DOWN PLATFORM DOWN GN/YL SW18 W4 WT PC BOARD BL BK SW17 RD RD BL YL OR 12V DC UP SIGNAL INPUT 13 U10 3 N.C. BK 1 SECOND TIME DELAY 12V DC OUTPUT 12 L7 Y7 EN9 JUNCTION BOX OPTION WH GROUND 10 DC MODEL: LOW BATTERY INDICATOR 2 WH BL LED13 12V DC INPUT 6 INDICATOR FOR AUXILIARY LOWERING BN OR LED12 12V DC INPUT 5 L6 BL WH LED14 12V DC INPUT 4 12V DC MOTOR RELAY OUTPUT 11 8 AA BATTERIES SW12 RD 16V AC INPUT 3 L5 WH RD/YL CENTER TAP INPUT 2 L14 L12 - RD 16V AC INPUT 1 LEVELING INDICATORS BK BL 3 POWER INDICATOR BK N.O. 2 NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT + THERMAL DEVICE YL U9 BK BL RD BK 4 P2 EMERGENCY STOP RD N.O. BK WH GND GROUND STUD SW8 BL GND GROUND STUD CONTROL ACTIVATE SWITCH BK RD CB1 BK UP 5 OR 3 EN2 15 AMP BL 2 GROUND CONTROL BOX WT N.O. WH 1 7 6 5 RD BK RD 2 BL 1 WH SW18 RD SW17 RD 6 BK GND BK BK GND GN/YL GROUND STUD GN/YL WH RD BK WH M5 GN/YL BK 7 GN/YL 6 RD YL 4 WH WH WH BK 3 WH 7 LS1 BL 2 TO PLATFORM PLATFORM EXTENTION MOTOR BL BK WT WH 7 OR 110V AC / 220V AC 4 GN 3 OR OR 6 BK 4 OR BK 3 WH RD 2 POWER UNIT QUICK DISCONNECT A 1 GROUND STUD GN/YL RD OR OR BK WH BK GN/YL BK OR QD3 1 BL WH D5 POWER SUPPLY AC STRAIN RELIEF RD POWER TO PLATFORM GFCI RECEPTACLE GN/YL YL 5 BK TO PLATFORM WH N.C. Y7 PLATFORM DOWN YL RD PLATFORM OUTREACH OPTION TO MOTOR BK BK WH QD7 POWER INPUT PLUG RD BL NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. WH *N17 EN4 TERMINAL STRIP BK DOWN GN/YL SW11 6 WH 4 N.C. PLATFORM UP/DOWN SWITCH 7 WH PLATFORM CONTROL BOX YL W6 QD4 TO BASE WH QUICK DISCONNECT B EN1 OR N 8 TO BASE Y30 N.O. DUMP VALVE QUICK DISCONNECT A TO PLATFORM QD3 BK Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 43 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC TUV Models with Base Mounted Junction Box ABBREVIATION LEGEND Item Description B Battery B4 = 8 AA batteries 15A circuit breaker Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Narrow platform units: WH and BK wires replace BL and OR wires Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW24 = Lift enable Electronic component U10 = PC board Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve CB1 D5 EN GND KS1 L LS1 M5 *N17 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BN BK GN GN/YL OR RD RD/YL WH YL Description Blue Brown Black Green Green/Yellow Orange Red Red/Yellow White Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC TUV Models without Base Mounted Junction Box L K J I H G F D C P1 BK 1 TRANSFORMER RD BK YL 1 N.C. KS1 GROUND/ PLATFORM RD RD BK BK N.O. + 3 W3 LEVELING INDICATORS L15 L13 B4 BL LED13 12V DC INPUT 6 RD LED15 12V DC INPUT 7 BK 12V DC OUTPUT 8 RD 12V DC OUTPUT 9 12V DC OUTPUT 9A WH GROUND 10 AUXILIARY DOWN TILT SENSOR OR 12V DC UP SIGNAL INPUT 13 DC MODEL: LOW BATTERY INDICATOR 3 S7 BK 1 SECOND TIME DELAY 12V DC OUTPUT 12 L7 SW12 2 WH OR LED12 12V DC INPUT 5 12V DC MOTOR RELAY OUTPUT 11 8 AA BATTERIES BN WH LED14 12V DC INPUT 4 INDICATOR FOR AUXILIARY LOWERING BL RD 16V AC INPUT 3 L6 WH RD/YL CENTER TAP INPUT 2 L5 L14 L12 - RD 16V AC INPUT 1 POWER INDICATOR BK N.O. 2 NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT BK W4 U10 PC BOARD BL W6 TERMINAL STRIP RD QD4 GROUND STUD BK BL GND GROUND STUD CONTROL ACTIVATE SWITCH 7 6 5 WH 4 CB1 OR 3 EN2 15 AMP BL 2 GROUND CONTROL BOX WT UP WH 1 7 6 3 OR SW18 2 BL BK 1 WH SW17 WH WH 6 BK GND GN/YL BK BASE BK GND GROUND STUD RD BK WH M5 GN/YL WH RD WH WH WH GN/YL WH BK 7 GN/YL 6 YL 4 BK 3 BL 2 WH OR WH BK BK PLATFORM EXTENTION OR 7 TO PLATFORM LS1 MOTOR BL BK YL 4 GN OR 6 BK 4 OR BK 3 OR 110V AC / 220V AC 5 DOWN BK 7 POWER UNIT RD GROUND STUD GN/YL N.O. Y7 PLATFORM WH RD BK QUICK DISCONNECT A TO PLATFORM POWER TO PLATFORM GFCI RECEPTACLE 5 GND BK STRAIN RELIEF WH RD BK OR 2 GN/YL QD3 1 BL POWER SUPPLY AC WH D5 1 WH GN GROUND STUD BK PLATFORM OUTREACH OPTION TO MOTOR BK BK WH QD7 POWER INPUT PLUG RD BL NARROW PLATFORM UNITS WH AND BK WIRES REPLACE BL AND OR WIRES. WH *N17 EN4 BK DOWN GN/YL PLATFORM UP/DOWN SWITCH RD TO BASE GND BK SW11 BK WH QUICK DISCONNECT B N.O. SW8 BK WH 4 P2 PLATFORM CONTROL BOX RD OR RD BL EMERGENCY STOP EN1 A THERMAL DEVICE YL U9 BK BL RD WH B U12 EMERGENCY STOP BL E WH M OR N QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE BK Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 44 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC TUV Models without Base Mounted Junction Box ABBREVIATION LEGEND Item Description B Battery B4 = 8 AA batteries 15A circuit breaker Power supply AC Enclosure EN1 = Platform control box EN2 = Ground control box EN4 = Power to platform GFCI receptacle Ground Key switch - ground/platform Led or light L5 = Power indicator (ground) L6 = Low battery indicator for auxiliary (ground) L7 = Low battery indicator — main (ground) L12 = Outrigger — front left (ground) L13 = Outrigger — front right (ground) L14 = Outrigger — rear left (ground) L15 = Outrigger — rear right (ground) Limit switch - platform extension (option) Hydraulic power unit Normally closed Normally open Power switch P1 = Emergency Stop button at ground controls P2 = Emergency Stop button at platform controls Quick disconnect QD3 = Control cable — to platform control box QD4 = Control cable — to base QD7 = Control cable — to motor Tilt sensor Switch SW 8 = Control activate SW11 = Platform up/down SW12 = Auxiliary down SW17 = Foot pad, left side SW18 = Foot pad, right side SW24 = Lift enable Electronic component U9 = Transformer U10 = PC board U12 = Thermal device Wiring component W3 = Terminal strip — 3 pole 3 pin (U10) W4 = Terminal strip — 14 pole 14 pin (U10) W6 = Terminal strip — 10 pole 20 pin (base) Valve coil Y7 = Platform down Y30 = Normally open dump valve CB1 D5 EN GND KS1 L LS1 M5 N.C. N.O. P QD S7 SW U W Y WIRE COLOR LEGEND Color BL BN BK GN GN/YL OR RD RD/YL WH WH/BK YL Description Blue Brown Black Green Green/Yellow Orange Red Red/Yellow White White/Black Yellow Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC TUV Models with Outreach M L K J I H G F E D C B A 1 RD P1 U12 EMERGENCY STOP N.C. RD RD BK YL RD BK 3 W3 L5 L14 L12 GROUND N.O. BK - BK BK RD BL L15 L13 B4 AUXILIARY DOWN RD LED15 12V DC INPUT 7 BK RD 12V DC OUTPUT 9 12V DC OUTPUT 9A 3 GN/YL RD S7 BK TILT SENSOR OR 12V DC UP SIGNAL INPUT 13 W4 U10 RD PC BOARD BL BK OR WH BK GN BL N.O. BL LED13 12V DC INPUT 6 1 SECOND TIME DELAY 12V DC OUTPUT 12 DC MODEL: LOW BATTERY INDICATOR 2 WH OR LED12 12V DC INPUT 5 GROUND 10 L7 SW12 BN WH LED14 12V DC INPUT 4 12V DC OUTPUT 8 INDICATOR FOR AUXILIARY LOWERING BL RD 16V AC INPUT 3 12V DC MOTOR RELAY OUTPUT 11 8 AA BATTERIES BL L6 WH RD/YL CENTER TAP INPUT 2 POWER INDICATOR KS1 RD 16V AC INPUT 1 NEGATIVE 12V DC INPUT POSITIVE 12V DC INPUT LEVELING INDICATORS + RD 2 BK BK THERMAL DEVICE TRANSFORMER 1 KS1 N.O. YL U9 BK PLATFORM 4 P2 W6 EMERGENCY STOP GN/YL EN2 WH 1 BK POWER UNIT 110V AC / 220V AC GND GROUND STUD GN/YL BK BK 7 GROUND STUD RD RD FROM BASE BK GND GN/YL 6 TO PLATFORM BK M5 BK WH GN/YL WH GN/YL WH GN/YL POWER TO PLATFORM GFCI RECEPTACLE WH WH LS1 MOTOR WH SW17 GN/YL WH OR EN4 BK 1 WH PLATFORM EXTENTION RD BL SW18 BL YL 7 2 BK 6 3 OR BL 4 YL WH 3 5 4 GN PLATFORM OUTREACH OPTION TO PLATFORM 2 N.O. PLATFORM DOWN BK QUICK DISCONNECT A 1 BK OR 7 Y7 WH RD OR 6 5 BK BK BK 4 2 STRAIN RELIEF RD BK 3 GN/YL 2 BL TO MOTOR RD BL QD3 1 OR POWER SUPPLY AC WH D5 RD BK WH GN/YL BK OR RD QD7 GN/YL 15 AMP POWER INPUT PLUG 5 7 6 GND GROUND STUD WH CB1 UP DOWN 6 OR 3 GROUND CONTROL BOX WT GN/YL BK PLATFORM UP/DOWN SWITCH 7 WH 4 GROUND STUD CONTROL ACTIVATE SWITCH BK BL GND GN/YL SW8 RD TO BASE GND GROUND STUD QUICK DISCONNECT B BK BK PLATFORM CONTROL BOX SW11 QD4 N.C. BK EN1 TERMINAL STRIP RD WH BL N QUICK DISCONNECT A Y30 TO PLATFORM 8 QD3 N.O. DUMP VALVE BK Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 45 Section 7 • Schematics First Edition • Second Printing Electrical Schematic IWP Super Series AC TUV Models with Outreach First Edition • Second Printing Section 7 • Schematics Hydraulic Schematic Legend Pressure Gauge Differential sensing valve Priority flow regulator Solenoid operated 2 position 2 way directional valve Solenoid operated 3 position 4 way directional valve Y30 Y7 Y5 Y4 Solenoid operated 2 position 2 way normally closed valve with manual over-ride Solenoid operated 2 position 2 way valve normally closed Y32 Solenoid operated 2 position 2 way valve, normally open M Check valve, pilot-operated Adjustable relief valve Relief valve Solenoid operated 2 position 3 way directional valve Solenoid operated dump valve Foot pump valve A Pump prime mover, electric motor 0.035/ 0.88mm Orifice with size NCV B Check Valve Cylinder single acting Cylinder double acting Pump, fixed displacement Wheel motor, fixed displacement Button operated 2 position 2 way directional valve Part No. 38139 Return filter Genie AWP Super Series and Genie IWP Super Series 7 - 46 Section 7 • Schematics First Edition • Second Printing Hydraulic Schematic Legend ABBREVIATION LEGEND ITEM A B C D E F DESCRIPTION Normally open dump valve Check valve Adjustable relief valve Normally closed down valve Flow control valve — pressure compensating Check valve Note: Use this legend for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Hydraulic Schematic AWP Super Series Models N M L K J I H G F E D C B A 1 CYLINDER ASSEMBLY 2 D Y7 F 3 E TANK PRESSURE 4 5 PRESSURE TANK A Y30 6 B C M5 M 7 1600 psi 110 bar 100 MESH 8 POWER UNIT ASSEMBLY Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 47 Section 7 • Schematics First Edition • Second Printing Hydraulic Schematic AWP Super Series Models ABBREVIATION LEGEND ITEM AI AL CV CV1 CV2 CV3 CV4 CV5 EN1 EN2 FC1 FC2 FS G1 KS1 M6 NCV NOV P1 P2 QD6 SW8 SW10 SW12 SW13 SW14 SW15 DESCRIPTION Compressed air indicator Air lubricator Check valve Main — pilot operated check valve Outrigger interlock valve — front left Outrigger interlock valve — front right Outrigger interlock valve — rear right Outrigger interlock valve — rear left Platform control box Ground control box Orifice - Flow control, hydraulic Orifice - Flow control, pneumatic Filter with water trap Pressure gauge — compressed air inlet Key switch — air supply on/off Air motor Normally closed down valve Normally open dump valve Emergency stop button - base Emergency stop button - platform Compressed air supply Control activate switch Platform up/down switch Outrigger interlock switch — front left Outrigger interlock switch — front right Outrigger interlock switch — rear right Outrigger interlock switch — rear left IMPORTANT NOTES Item Description Dotted line Solid line Indicates pnuematic route Indicates hydraulic route Note: Use these 2 legends for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Hydraulic/Pneumatic Schematic AWP Super Series Models N M L K J I H G F E D C B A 1 CYLINDER ASSEMBLY G1 QD6 FS CV1 AL MAIN OUTRIGGER ENABLE VALVE AIR LUBRICATOR CYL FC2 NCV EN2 GROUND CONTROL BOX P1 CV KS1 BASE EMERGENCY STOP 2 EN1 3 PLATFORM CONTROL BOX P2 EMERGENCY STOP SW10 SW8 CONTROL ACTIVATE SWITCH N.C. SW12 SW13 FC1 PLATFORM UP/DOWN SWITCH UP 4 DOWN SW14 SW15 5 AI AI AI AI CV2 CV3 CV4 CV5 PRESSURE TANK 6 NOV RV1 1600 psi 110 bar MUFFLER 7 M M6 AIR MOTOR 100 MESH 8 POWER UNIT ASSEMBLY Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 48 Section 7 • Schematics First Edition • Second Printing Hydraulic/Pneumatic Schematic AWP Super Series Models ABBREVIATION LEGEND ITEM A B C D E F G H I J K L DESCRIPTION Normally open dump valve Check valve Adjustable relief valve Normally closed down valve with manual override Flow control valve — pressure compensating Check valve Check valve, system pressure Check valve, directs flow to tank Manual release valve, lowers base Relief valve, outer base frame Check valve, pilot operated Foot pump Note: Use this legend for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Hydraulic Schematic IWP Super Series Models without Power Assist N M L K J I H G F E D BASE LIFT CYLINDER OR A B G J A PLATFORM LIFT CYLINDER .030’’ (0.760 mm) .030’’ (0.760 mm) 1600 psi (110 bar) B 1 CYL I C 2 K L D H 3 F Y7 FOOTPUMP MANIFOLD ASSY. E TANK 4 TANK PRESSURE 5 6 PRESSURE TANK A Y30 B 7 C M5 M 1600 psi (110 bar) 8 100 MESH POWER UNIT ASSEMBLY Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 49 Section 7 • Schematics First Edition • Second Printing Hydraulic Schematic IWP Super Series Models without Power Assist ABBREVIATION LEGEND ITEM A B C D E F G H I J K L AA AB AC AD DESCRIPTION Normally open dump valve Check valve Lift relief valve Flow control valve — pressure compensating Check valve Normally closed down valve with manual override Check valve, base lift Check valve, inlet to foot pump Manual release valve, lowers base Relief valve, outer base frame Check valve, pilot operated Check valve, foot pump Check valve, system pressure Solenoid valve, all functions Solenoid valve, forward-reverse Relief valve, power wheel assist Note: Use this legend for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Hydraulic Schematic IWP Super Series Models with Power Assist N M L K J I H G F E D C B A 1 AT PRESSURE TANK AD AA TANK 1600 psi 110 bar POWER WHEEL ASSIST MOTOR B A AB Y5 A 2 C AC M2 A Y32 3 P B M5 Y4 M1 POWER WHEEL ASSIST MANIFOLD ASSY. M 100 MESH HYDRAULIC POWER UNIT 4 5 BASE LIFT CYLINDER .030 in 0.760 mm 6 F D .030 in 0.760 mm G I K E PLATFORM LIFT CYLINDER L J 1600 psi 110 bar 7 H 8 FOOTPUMP MANIFOLD Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 50 Section 7 • Schematics First Edition • Second Printing Hydraulic Schematic IWP Super Series Models with Power Assist ABBREVIATION LEGEND ITEM A B C D E F G H I J K L CA CB CC CD CE DESCRIPTION Solenoid operated normally open dump valve Check valve Lift relief valve Flow control valve — pressure compensating Check valve Solenoid operated lowering valve with manual override Check valve, base lift Check valve, inlet to foot pump Manual release valve, lowers base Relief valve, outer base frame Check valve, pilot operated Check valve, foot pump Check valve, system pressure Solenoid valve, all functions Solenoid valve, forward-reverse Relief valve, power wheel assist Relief valve, cross port Note: Use this legend for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Hydraulic Schematic IWP Super Series Models with Power Assist and Brakes N M L K J I H G F E D C B A 1 TEST AT TANK CA CD TANK 1600 psi 110 bar M2 750 psi 51.7 bar A B A CB Y5 A 2 1600 psi 110 bar CC CE PRESSURE C Y32 3 P B M5 Y4 M1 POWER ASSIST MANIFOLD ASSY. M 100 MESH HYDRAULIC POWER UNIT 4 5 BASE LIFT CYLINDER .030 in 0.760 mm 6 D F .030 in 0.760 mm G I K E PLATFORM LIFT CYLINDER L J 1600 psi 110 bar 7 H 8 FOOTPUMP MANIFOLD Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 51 Section 7 • Schematics First Edition • Second Printing Hydraulic Schematic IWP Super Series Models with Power Assist and Brakes ABBREVIATION LEGEND ITEM A B C D E F G H I J K L BA BB BC BD DESCRIPTION Normally open dump valve Check valve Adjustable relief valve Normally closed down valve Flow control valve — pressure compensating Check valve Check valve, system pressure Check valve, directs flow to tank Manual release valve, lowers base Relief valve, outer base frame Check valve, pilot Check valve, foot pump Check valve, system pressure Solenoid valve, all functions Solenoid valve, forward-reverse Solenoid valve, system relief Note: Use this legend for the schematic on the opposing page. Section 7 • Schematics First Edition • Second Printing Hydraulic Schematic IWP Super Series Models with Power Assist, Brakes and Cross Port Relief N M L K J I H G F E D C B A 1 TEST AT 1600 psi 110 bar TANK BA B A BB POWER ASSIST MOTOR M2 Y5 2 A 1600 psi 110 bar BC A PRESSURE TANK BD C Y32 3 P B M5 Y4 M1 POWER WHEEL ASSIST MANIFOLD ASSY. M 100 MESH 4 HYDRAULIC POWER UNIT 5 BASE LIFT CYLINDER .030 in 0.760 mm 6 F D .030 in 0.760 mm G I K E PLATFORM LIFT CYLINDER L J 1600 psi 110 bar 7 H 8 FOOTPUMP MANIFOLD Part No. 38139 Genie AWP Super Series and Genie IWP Super Series 7 - 52 Section 7 • Schematics First Edition • Second Printing Hydraulic Schematic IWP Super Series Models with Power Assist, Brakes and Cross Port Relief Phone 425.881.1800 Toll Free USA and Canada 800.536.1800 Fax 425.883.3475 Genie Australia Pty Ltd. Genie Scandinavia Phone +46 31 575100 Fax +46 31 579020 Genie France Phone +33 (0)2 37 26 09 99 Fax +33 (0)2 37 26 09 98 Genie Iberica Phone +34 93 579 5042 Fax +34 93 579 5059 Genie Germany Phone Phone Fax 0800 180 9017 +49 422 149 1818 +49 422 149 1820 Genie U.K. Phone +44 (0)1476 584333 Fax +44 (0)1476 584334 Genie Mexico City Phone +52 55 5666 5242 Fax +52 55 5666 3241 Phone +61 7 3375 1660 Fax +61 7 3375 1002 Genie China Phone +86 21 53852570 Fax +86 21 53852569 Genie Malaysia Phone +65 98 480 775 Fax +65 67 533 544 Genie Japan Phone +81 3 3453 6082 Fax +81 3 3453 6083 Genie Korea Phone +82 25 587 267 Fax +82 25 583 910 Genie Brasil Phone +55 11 41 665 755 Fax +55 11 41 665 754 Genie Holland Phone +31 183 581 102 Fax +31 183 581 566 Distributed By: Genie North America