New ERGYS Upgrades!
Transcription
New ERGYS Upgrades!
Refurbishing the ERGYS A Guide to Upgrading, Repairing, and Refurbishing the ERGYS Therapeutic Alliances Inc. 333 North Broad Street Fairborn, Ohio 45324 USA (937) 879-0734 • (937) 879-5211 (fax) • www.ERGYS.com • [email protected] ERGYS® is a trademark of Therapeutic Alliances Inc. ns Versio H.6 d H.4 an Features a Programmable target cadences from 32 RPM to 70 RPM. ERGYS a Muscle "Firing Patterns" shift dependent on target cadence. a Fatigue limit is programmable down to 10 RPM. VARIABLE CADENCE SOFTWARE ©2005 THERAPEUTIC ALLIANCES INC. ALL RIGHTS RESERVED. INITIALIZING... ©2005 THERAPEUTIC ALLIANCES INC. VERSION H.6 -><- A new icon, -><-, appears on the Copyright Display if the Token Data System is present. The appearance of the icon signifies that the lastsaved parameters on the Token are being loaded. In the absence of the Data Token System, pressing NEXT will load the default session parameters. Optionally, session parameters can be loaded from a PC per the ERGYS View protocol. CONTROL RPM x FATIGUE RPM a No attempt from the 1 to 2 minute marks of a run to increase resistance to the target. a PC Interface. ERGYS can be connected to a PC to capture real-time session data. VERSION H.6 The new ERGYS version is displayed after the title screen. For better readability, this display now appears in all upper case characters. ALL RIGHTS RESERVED. a No resistance application in the manual mode unless INC is pressed. y RPM SETTINGS - REDO OR NEXT Previous ERGYS software set the target (control) cadence at 49 RPM and the fatigue cut-off at 35 RPM. These settings could not be changed. The new software allows for target RPM settings from 32 to 70 and a range of fatigue cut-off settings from 10 RPM to just under the setting for the target RPM. If the RPM settings are changed, a message lets the user know that the ERGYS is calculating new stimulus patterns to best match the new RPM settings. WARM UP MM:SS RPM: x PEDAL SPEED MUST EXCEED y RPM Previous ERGYS software versions required cadences above 35 RPM before the Warm Up count-up and the Cool Down count-down could proceed. The new software sets this cadence at the Fatigue RPM level set on the Target RPM display. Therapeutic Alliances Inc. 333 North Broad Street Fairborn, Ohio 45324 USA (937) 879-0734 • (937) 879-5211 (fax) • www.ERGYS.com • [email protected] ns o i s r e V H.6 d n a H.4 RUN #9 MM:SS Variable Cadence Software COMPLETED MM:SS OF MM:SS MAX LOAD: 7/8 Kp SELECTED: 7/8 Kp AUTO Session time information now appears before each run. AUTOERGO+R n.n MILES 100% MAX STIM RUN TIME MM:SS y% of z/8 Kp n RPM The word 'AUTO' has been replaced by 'AUTOERGO' on the Auto Ergometry display. This change was made to eliminate the confusion between the word 'Auto' on this display (meaning Auto Ergometry) and the word 'Auto' that appears on the Resistance Setting display (meaning the Automatic Resistance Mode). AUTOERGO When not on this display... Electric brake available for prepping Version H.6 allows the pedal crank to be locked electronically for prepping. This electric lock is toggled on or off by pressing the ‘END’ key on any display except the AUTO ERGO display. Case Studies þ Joe in Minneapolis - T-level SCI unable to ride without assistance after 6 months of ERGYS sessions. 6 minute rider with new software. þ Mike in Kentucky - C-3/4 Quad unable to ride without assistance during the first session. 2 minute rider with new software. Strategies ~ Low target and fatigue RPM settings = Less stimulus required for riders with substantial to moderate sensation ~ More of muscle is recruited with the longer "on" times of slower cadences ~ ERGYS View software for PC data collection and analysis ~ And more! Other Great ERGYS Upgrades Wonderdog Productions Your ERGYS can be upgraded! Contact Therapeutic Alliances to see how. Therapeutic Alliances Inc. 333 North Broad Street Fairborn, Ohio 45324 USA (937) 879-0734 • (937) 879-5211 (fax) • www.ERGYS.com • [email protected] Converting from a Mechanical to an Electronic Crank Lock Install the new ERGYS software. Refer to the separate instructions for this. With the new software installed, pressing the ‘END’ key on the keypad (or the LOCK key on newer ERGYS systems) will lock the drive train as an aid in prepping for a session. 1 2 Remove the right side boot assembly and the drive train cover to access the crank lock bolt. Remove the crank lock bolt to render the mechanical crank lock inoperable. This will prevent wear and tear and damage to the crank assembly. You may opt to keep the bolt in place, but keep in mind that the ERGYS can be damaged if the brake is engaged while the drive train is moving. 3 Replace the old ‘Lock/Unlock’ label with the new label. Therapeutic Alliances Inc. 333 North Broad Street Fairborn, Ohio 45324 USA (937) 879-0734 • (937) 879-5211 (fax) • www.ERGYS.com • [email protected] ERGYS® is a trademark of Therapeutic Alliances Inc. rev. 20050328 Padding to protect crank gear teeth during assembly Large-jaw pliers to remove crank gear Disposable gloves Grease to pack crank bearings Crank bearings and hardware Permanent threadlocker Threaded crank gear Tie wraps to hold resolver plate during assembly 1 ¼ wrench for newer ERGYS system 1 3/16 for older systems