PRODUCTS RANGE | ENGLISH

Transcription

PRODUCTS RANGE | ENGLISH
> PRODUCTS RANGE | ENGLISH
The PRAMAC Group represents a solid industrial reality, from manufacturing to commercialization. Its strong international
presence has been consolidated in the generators and material handling markets, through an aggressive growth that
has found place in the most varied and demanding markets.
PRAMAC is a young and dynamic company, that has projected its development and experience, gained by the merger between
different production realities, incorporating all efforts in one single objective: to offer better solutions to our clients.
Thanks to the combination between team work, the operational flexibility due to the worldwide commercial and manufacturing
presence, and the close bond with sports and its values, PRAMAC introduces a new commercial structure,
developed to achieve with best success each market concrete demands.
In the generating area, PRAMAC generators bring into the market more than 1.300.000 kVA per year, divided in a power range
units from 1 to 2500 kVA, offering solutions for every kind of demand: energy where main supplies are not available and
uninterrupted energy where it cannot fail, energy for those working and energy for entertaining.
At the same time, PRAMAC offers a professional line of power tools, as high pressure washers, welder generators,
PTO generator, motorpumps and illuminating systems, presenting the highest perfomance and reliability.
PRAMAC has always dedicated resource and energy to the most demanding markets, as a true symbol
of its experience built under one vision: to offer the best cost-benefit relationship, enhanced
by a strong strategic relationship with first level components partners.
PRO heavy duty is the result of in depth market analysis, where we have identified and recognized
specific needs that arise in heavy duty applications, such as construction sites, rental or agricultural locations.
For these applications PRAMAC has given priority to endurance, reliability and safety.
CONFORMS
TO THE EUROPEAN
SAFETY RULES
The strategic objective to exceed the expectations of the customer can only be reached if the products are
of the highest possible quality. The PRAMAC Group has taken this on in its philosophy in production.
The continual improvement in the company processes, formulated with absolute respect for the environment
and the specialised training of its staff, forms part of the Total Safety and Quality programme that the company sets itself.
There is a real Safety and Quality Culture inside the company, starting from respect for the environment and regard
for the specific regulations. Concrete evidence of this commitment is the certifications that the company
has obtained on both the European level and extra-European level.
Special offer on an engine kit
On-line spare parts
order and interactive
spare parts catalogues
Planned preventive
maintenance
Personalised
solutions with 24/7
on call service
Service support
Installations
and commissioning
Training program
Dedicated training
program for users,
maintenance,
and after sales service
SERVICE AND PARTS
PRAMAC Service and Parts represents PRAMAC's commitment to Customer Care and Satisfaction.
The creation of a highly specialised business unit, completely devoted to After Sales Customer Service,
proves the PRAMAC intent to support its Customers at every stage of the professional relationship.
On top of this, an incredible wide range of spare parts and components, with highly trained, professional staff,
is what the PRAMAC Service and Parts division offers, answering requests from Customers all around the world.
Attention to detail and consideration of users requirements is the core of an efficient after sales service.
The focus and motto of the Service and Parts division is: Our Customers are Our First Priority.
Our activity is the corner stone that makes our products valuable. For this reason we develop special actions
for our dealer customers and end users, giving support through schedule maintenance programs,
installation and commisioning services, training activities, and a constant, active support through our website:
www.pramacparts.com
PRODUCT RANGE
INDUSTRIAL GENERATORS OPEN SET
PORTABLE GENSET & POWER EQUIPMENT
GBA 6-17d
pag. 8
ES SERIES
pag. 56
GSA 22-65d
pag. 10
S SERIES
pag. 58
GBW 15-45p / y
pag. 12
SP SERIES
pag. 62
GSL 30-42d
pag. 14
P SERIES
pag. 64
GSW 65-170d
pag. 16
W SERIES
pag. 68
GSW 195-220d
pag. 18
GSW 530-560d
pag. 20
HIGH PRESSURE WASHERS
GSW 275-590V
pag. 22
ZG SERIES
WELDER GENERATOR
PW SERIES
pag. 70
pag. 71
PTO SHAFT GENERATOR
MP SERIES
INDUSTRIAL GENERATORS SOUNDPROOF
pag. 72
PRESSURE WASHER
GBL 30-42d
pag. 24
LIGHT GLOBE
pag. 73
GSL 30-42d
pag. 26
LIGHT TOWER
pag. 74
GBW 15-45p / y
pag. 28
HE SERIES
pag. 75
GBW 65-110p
pag. 30
GSW 15-22p
pag. 32
GSW 15-22d
pag. 34
GSW 65-170d
pag. 36
GSW 195-220d
pag. 38
GSW 530-560d
pag. 40
GSW 275-590V
pag. 42
HOIST
ELECTRICAL EQUIPMENT
CUSTOMISED SOLUTIONS
GPW SERIES
pag. 46
GCW UNITS
pag. 54
AMF
pag. 77
PANELS
pag. 78
1
3
6
9
12
15
20
30
45
65
80
110
145
170
195
220
275
330
415
450
510
590
1500 2500 kVA
GBA Deutz/Lombardini Series
GBW Perkins/Yanmar Series
GSA Deutz/Lombardini Series
INDUSTRIAL
GENSETS
GSL Deutz Series
Standard Solutions
GSW Deutz Series
GSW Volvo Series
GSW Deutz/Perkins Series
GBL Deutz Series
INDUSTRIAL
GENSETS
GSW Volvo Series
Standard Solutions
GBWPerkins/Yanmar Series GBW Deutz Series
GSW Deutz Series
GPW - Special Solutions
INDUSTRIAL
GENSETS
GCW - Customised Solutions
Customised Solutions
ES Class
S Class
PORTABLE
GENSETS
P Class
SP Class
POWER
EQUIPMENT
30
30 - 220 A
Semi Pro
Pro
OPENSET
SOUNDPROOF
PORTABLE
CUSTOMISED
Power (LTP) 8 - 32 kVA (three phase)
Flow 600 - 1340 l/min (Semi trash & Trash)
Welding current range 170 - 220 A
Pressure from 110 - 240 bar
250 - 2000 W (25.500 - 189.000 lumen)
51.700 lm (Portable genset) - 200.000 lm (Stationary genset)
load to 125/ 200/ 500 Kg
PTO GENERATORS
MOTOR PUMP
WELDER GENERATORS
HIGH PRESSURE WASHERS
LIGHTGLOBE
LIGHT TOWER
HOIST
INDUSTRIAL GENERATORS OPEN SET GBA 6d-17d
GBA SERIES
ENERGY FOR
ALL YOUR NEEDS
The GBA series are the simplest way to fulfill particular
power demands. The high quality components make
these generators very reliable and easy to use. They are
also ideal for starting and powering motor pumps.
High autonomy fuel tank
Efficient air filtration systems
Rated battery capacity
Fuel tank integrated on engine
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
GBA6d
GBA12L
GBA14d
GBA17d
three phase
three phase
three phase
three phase
4,7/5,9
4,5/5,6
400
50
3
9,1/11,3
8,2/10,2
400
50
3
10,7/13,4
10,2/12,8
400
50
3
13,0/16,2
12,01/15,1
400
50
3
Deutz
D909 L1
Diesel
1
710
Natural
Air
Electric
1500
Mechanical
5,8
5,5
2,1
NA
1,14
1,53
12
Lombardini
9LD 625
Diesel
2 in line
1248
Natural
Air
Electric
1500
Mechanical
10,7
9,6
2,8
NA
2,4
3,2
12
Deutz
F2L2011
Diesel
2 in line
1550
Natural
Air
Electric
1500
Mechanical
12,6
12
6
NA
2,57
3,43
12
Deutz
D910L2
Diesel
2 in line
1650
Natural
Air
Electric
1500
Mechanical
15,1
14
4
NA
3,01
4,02
12
Linz
E1S13 S/4/7,5
4
7,42
81,3
Compound
Linz
E1S13 S/4/11
4
11,6
84,8
Compound
Linz
E1S13 M/4/13
4
13,8
85,4
Compound
Linz
E1S13 M/4/16
4
17
86,3
Compound
1226
700
960
267
14,5
12,67
1226
700
960
244
10
4,17
1400
750
1180
468
91
35,39
1226
700
1060
420
50
16,6
Panels
- MCP Analogue n° 1, pag. 78
9
INDUSTRIAL GENERATORS OPEN SET GSA 22d-65d
GSA SERIES
CONSTANT
POWER SUPPLY
The GSA generators provide peace-of-mind:
with a greatly extended running time, these sets
offer a professional solution against main power
failures, maintaining a constant power supply.
Accessories
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Load Transfer Switch Panel (LTS) for ACP versions
Single phase version
Residential silencer
Flexible exhaust compesator
Engine electronic governor
Load Transfer panel
Highly efficient alternator
Steel base frame with bolted support legs
Wide range of accesories
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
(1)
GSA22d
GSA30d
GSA42d (1)
GSA65d (1)
three phase
three phase
three phase
three phase
16,2/20,2
15,2/19,0
400
50
3
24,0/30,0
23,2/29,0
400
50
3
32,8/41,0
32,0/40,0
400
50
3
49,7/62,1
48,8/61,0
400
50
3
Deutz
F3L2011
Diesel
3 in line
2330
Natural
Air
Electric
1500
Mechanical
20
19
5,5
NA
3,58
4,78
12
Deutz
F4L2011
Diesel
4 in line
3110
Natural
Air
Electric
1500
Mechanical
29
27,6
10
NA
5,27
7,03
12
Deutz
F4L912
Diesel
4 in line
3770
Natural
Air
Electric
1500
Mechanical
38
37
11
NA
7,07
9,43
12
Deutz
F6L912
Diesel
6 in line
5650
Natural
Air
Electric
1500
Mechanical
56
55
13,5
NA
10,51
14,01
12
Linz
E1S13 M/4/19
4
20,14
86,5
Compound
Stamford
BCI 184F
4
30
85,8
Electronic
Stamford
BCI 184J
4
45
86,6
Electronic
Stamford
UCI 224E
4
63
88,8
Electronic
1400
750
1700
510
90
25,12
1400
750
1700
655
90
17,08
1800
750
1710
776
90
12,73
2200
1000
1620
954
240
22,84
This Generator is normally intended to be used for industrial application only. In this case, its engine would not have to comply with EU 97/68/EC Stage II (EU2007) Directive
(no need for subsequent modifications and/or integrations).
Panels
- MCP Digital n° 2, pag. 78
- MCP Analogue n° 3, pag. 78
- ACP n° 4, pag. 78
11
INDUSTRIAL GENERATORS OPEN SET GBW 15-45p/y
GBW SERIES
POWER AND VERSATILITY
The GBW Series are reliable and powerful machines designed for professional
use in construction sites and other industrial applications. With an excellent
performance and easy installation they can be used either to support electricity
mains failure or isolated locations.
Accessories
Coolant pre-heating system (for automatic start)
Load Transfer Switch Panel (LTS) for ACP versions
Single phase version
Load Transfer panel
Standard socket combination
Fuel filter
Water radiator cap
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
GBW15p
GBW15y
GBW22p
GBW22y
GBW30p
GBW30y
GBW45p
GBW45y
three phase
three phase
three phase
three phase
three phase
three phase
three phase
three phase
11,0/13,8
10,1 / 12,7
400
50
3
11,04 / 13,8
10,4 / 13,0
400
50
3
16,1 / 20,1
15,2 / 19,0
400
50
3
16,1 / 20,1
15,2 / 19,0
400
50
3
24,0 / 30,0
23,2 / 29,0
400
50
3
26,4 / 33,0
26,0 / 32,5
400
50
3
36,0 / 45,0
35,2 / 44,0
400
50
3
36,0 / 45,0
35,2 / 44,0
400
50
3
Perkins
403C-15G
Diesel
3 in line
1496
Natural
Water
Electric
1500
Mechanical
13,3
12,0
6,0
6,0
2,7
3,6
12
Yanmar
3TNV88
Diesel
3 in line
1642
Natural
Water
Electric
1500
Mechanical
14,5
13,2
6,7
2,0
2,8
3,7
12
Perkins
404C-22G
Diesel
4 in line
2216
Natural
Water
Electric
1500
Mechanical
20,3
18,4
10,6
7,0
3,8
5,1
12
Yanmar
4TNV88
Diesel
4 in line
2190
Natural
Water
Electric
1500
Mechanical
19,5
17,7
10,6
7,0
3,8
5,1
12
Perkins
1103A-33G
Diesel
3 in line
3300
Natural
Water
Electric
1500
Mechanical
30,4
27,7
7,9
10,2
5,1
6,8
12
Yanmar
4TNV98
Diesel
4 in line
3319
Natural
Water
Electric
1500
Mechanical
37,5
34,1
10,5
4,2
6,1
8,1
12
Perkins
1103A-33TG1
Diesel
3 in line
3300
Natural
Water
Electric
1500
Mechanical
45,6
41,3
7,9
10,2
7,8
10,4
12
Yanmar
4TNV98T
Diesel
4 in line
3319
Natural
Water
Electric
1500
Mechanical
45,5
41,4
10,5
4,2
8,7
11,6
12
Linz
E1S13 M/4/19
4
20,1
86,5
Compound
Linz
E1S13 M/4/19
4
20,1
86,5
Compound
Stamford
BCI 184F
4
30,0
85,8
Electronic
Stamford
BCI 184G
4
33,0
85,8
Electronic
Stamford
BCI 184J
4
45,0
86,6
Electronic
Stamford
BCI 184J
4
45,0
86,6
Electronic
1600
870
1000
480
51
13,3
1600
870
1000
408
51
13,3
2000
920
1100
700
51
10,0
2000
920
1100
583
51
8,4
2000
920
1100
785
51
6,5
2000
920
1100
673
51
5,9
Linz
Linz
E1S13 M/4/13 E1S13 M/4/13
4
4
13,8
13,8
85,4
85,4
Compound
Compound
1600
870
1000
410
51
18,7
1600
870
1000
280
51
18,3
Panels
- MCP n° 5, pag. 79
- ACP n° 6, pag. 79
13
INDUSTRIAL GENERATORS OPEN SET GSL 30d-42d
GSL SERIES
AN ALTERNATIVE
POWER SUPPLY
Great performance from these oil cooled engine
generators, offering reliable power with easy installation.
The GSL series are perfect for locations not
connected to a main power supply.
ALSO FOR BIODIESEL 100%
Accessories
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Single phase version
Residential silencer
Flexible exhaust compesator
Engine electronic governor
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Integrated oil cooling system
Industrial silencers
Replaceable cartridge air filter
Optimized anti-vibration pads
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
GSL30d
GSL42d
three phase
three phase
24,0/30,0
23,2/29,0
400
50
3
33,0/41,3
31,5/39,3
400
50
3
Deutz
F4M2011
Diesel
4 in line
3110
Natural
Oil
Electric
1500
Mechanical
29
27,6
10
NA
5,32
7,09
12
Deutz
BF4M2011
Diesel
4 in line
3110
Turbo
Oil
Electric
1500
Mechanical
38,2
36,4
10
NA
7,05
9,4
12
Stamford
BCI 184F
4
30
85,8
Electronic
Stamford
BCI 184J
4
45
86,6
Electronic
1800
750
1720
714
90
16,92
1800
750
1720
761
90
12,76
Panels
- MCP Digital n° 2, pag. 78
- MCP Analogue n° 3, pag. 78
- ACP n° 4, pag. 78
15
INDUSTRIAL GENERATORS OPEN SET GSW 65d-170d
GSW SERIES
ENERGY FOR PUBLIC
AND INDUSTRIAL USES I
The GSW range is available with a range of accessories providing a versatile
solution to a variety of applications e.g. to support Telecommunications sites.
Accessories
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Single phase version
Residential silencer
Flexible exhaust compesator
Engine electronic governor
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Steel base frame with bolted support legs
Latest technology electronic devices
Avaibility of different cubicle solutions
Battery
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
(1)
GSW65d
GSW80d
GSW110d
GSW145d (1)
GSW170d
three phase
three phase
three phase
three phase
three phase
50/63
46/58
400
50
3
64/80
62/77
400
50
3
86/108
82/102
400
50
3
113/142
108/135
400
50
3
134/167
127/159
400
50
3
Deutz
BF4M2012 G2
Diesel
4 in line
4040
Turbo
Water
Electric
1500
Mechanical
58
52
8,5
15,9
10,26
13,68
12
Deutz
BF4M2012C
Diesel
4 in line
4040
Turbo, CAC
Water
Electric
1500
Mechanical
79,7
70,7
8,5
17,9
13,31
17,74
12
Deutz
BF4M1013EC
Diesel
4 in line
4760
Turbo, CAC
Water
Electric
1500
Mechanical
96,1
91,1
11
19,7
16,67
22,23
12
Deutz
BF6M1013E
Diesel
6 in line
7150
Turbo
Water
Electric
1500
Mechanical
123,8
117,8
20
23,1
21,88
29,17
12
Deutz
BF6M1013EC
Diesel
6 in line
7150
Turbo, CAC
Water
Electric
1500
Mechanical
145,1
138,1
20
23,1
24,54
32,72
12
Stamford
UCI 224E
4
63
88,8
Electronic
Stamford
UCI 224F
4
80
89,9
Electronic
Stamford
UCI 274C
4
110
90,3
Electronic
Stamford
UCI 274E
4
150
91,7
Electronic
Stamford
UCI 274F
4
175
92,3
Electronic
2200
1000
1620
865
240
23,39
2200
1000
945
TBA
240
18,04
2200
1000
1620
1326
240
14,39
2600
1000
1620
1545
250
11,43
2600
1000
1620
1615
250
10,19
This Generator is normally intended to be used for industrial application only. In this case, its engine would not have to comply with EU 97/68/EC Stage II (EU2007) Directive
(no need for subsequent modifications and/or integrations).
Panels
- MCP Digital n° 2, pag. 78
- MCP Analogue n° 3, pag. 78
- ACP n° 4, pag. 78
17
INDUSTRIAL GENERATORS OPEN SET GSW 195d-220d
GSW SERIES
ENERGY FOR PUBLIC
AND INDUSTRIAL USES II
With a wide range of accessories these generators are able to satisfy the
requirements of many different applications. Exceptional load acceptance
characteristics and constant voltage output is guaranteed due to the electronic
governor which is installed as standard.
Accessories
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Residential silencer
Flexible exhaust compesator
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Highly efficient alternators
Hot parts protection
Long autonomy fuel tanks
Air filter indicator
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
GSW195d
GSW220d
three phase
three phase
155/194
149/186
400
50
3
176/220
166/208
400
50
3
Deutz
BF6M1013FCP G2
Diesel
6 in line
7150
Turbo intercooler
Water
Electric
1500
Electronic
178,6
161,6
20
27,3
32,9
43,86
24
Deutz
BF6M1013FCP G3
Diesel
6 in line
7150
Turbo intercooler
Water
Electric
1500
Electronic
196,6
178,6
20
27,3
36,84
49,12
24
Stamford
UCI 274G
4
194
92,4
Electronic
Stamford
UCI 274H
4
220
93,3
Electronic
2650
1100
1965
1980
410
12,46
2650
1100
1980
1964
410
11,13
Panels
- MCP Digital n° 2, pag. 78
- MCP Analogue n° 3, pag. 78
- ACP n° 4, pag. 78
19
INDUSTRIAL GENERATORS OPEN SET GSW 530d-560d
GSW SERIES
POWERFUL GENERATION
This family of generators offers the best perfomance
under the most difficult and variable operation conditions.
Ideal for major industrial areas that need an extra power source.
Accessories
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Residential silencer
Flexible exhaust compesator
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Terminal board load connection
Electronical controlled engine
Moving and rotating parts protection
Set of documentation available
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
GSW530d
GSW560d
three phase
three phase
422/528
367/459
400
50
3
437/546
407/509
400
50
3
Deutz
Deutz
BF8M1015C G2
BF8M1015CP
Diesel
Diesel
8V
8V
15900
15900
Turbocharged intercooler Turbocharged intercooler
Water
Water
Electric
Electric
1500
1500
Electronic
Electronic
449,7
475,9
391,3
433,9
45
45
102
116
72,32
85,62
96,43
114,16
24
24
Mecc-Alte
ECO40 3S/4
4
546
94,2
Electronic
Mecc-Alte
ECO40 3S/4
4
546
94,2
Electronic
3300
1800
2135
3600
636
8,79
3300
1800
2135
3750
636
7,43
Panels
- ACP n° 8, pag. 79
21
INDUSTRIAL GENERATORS OPEN SET GSW 275V-590V
GSW SERIES
POWER IN ISOLATION
A continuous power supply, provided by high power output
and extended running time, makes this range
of generators the most suitable for powering sites
not connected to a mains power supply.
This range is also ideal for running lighting systems
during power failures.
Accessories
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Residential silencer
Flexible exhaust compesator
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Well balanced engine block 6 in line cilinders
Efficiency in noise attenuation
Manual oil drain pump
Synchronous brushless alternators
1% voltage regulation
GSW275V
GSW330V
GSW415V
GSW450V
GSW510V
GSW560V
GSW590V
three phase
three phase
three phase
three phase
three phase
three phase
three phase
GENERATING SET
STAND BY POWER LTP kW/kVA
220/275
264/330
331/414
350/437
406/507
437/546
481/601
PRIME POWER PRP kW/kVA
202/252
252/315
302/378
329/411
369/461
404/505
457/571
VOLTAGE Volt
400
400
400
400
400
400
400
FREQUENCY Hz
50
50
50
50
50
50
50
PHASES
3
3
3
3
3
3
3
ENGINE
MODEL
Volvo
Volvo
Volvo
Volvo
Volvo
Volvo
Volvo
TYPE
TAD734GE
TAD941GE
TAD1241GE
TAD1242GE
TAD1640GE
TAD1641GE
TAD1642GE
FUEL
Diesel
Diesel
Diesel
Diesel
Diesel
Diesel
Diesel
NUMBER AND DISPOSITION OF CYLINDERS
6 in line
6 in line
6 in line
6 in line
6 in line
6 in line
6 in line
DISPLACEMENT cc
7150
9360
12130
12130
16120
16120
16120
ASPIRATION
Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler
COOLING SYSTEM
Water
Water
Water
Water
Water
Water
Water
STARTING SYSTEM
Electric
Electric
Electric
Electric
Electric
Electric
Electric
SPEED rpm
1500
1500
1500
1500
1500
1500
1500
SPEED GOVERNOR
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
STAND BY POWER LTP kW
241
320
354
387
432
473
536
PRIME POWER PRP kW
216
290
323
352
393
430
485
LUBE OIL CAPACITY (MAX) L
29
35
35
35
48
48
48
COOLANT CAPACITY (MAX) L
32
41
44
44
93
93
93
FUEL CONSUMPTION at 75% PRP L/h
39,29
48,45
57,1
62,54
68,07
76,02
87,04
FUEL CONSUMPTION at 100% PRP L/h
52,38
64,61
76,14
83,39
90,76
101,36
116,05
ELECTRICAL CIRCUIT Volt
24
24
24
24
24
24
24
ALTERNATOR
MODEL
Mecc-Alte
Mecc-Alte
Mecc-Alte
Mecc-Alte
Mecc-Alte
Mecc-Alte
Mecc-Alte
TYPE
ECO38 1L N4
ECO38 2L N4
ECO40 1S/4
ECO40 1S/4
ECO40 3S/4
ECO40 3S/4
ECO40 1L/4
POLES
4
4
4
4
4
4
4
STAND BY 163/27°C rating - LTP kVA
275
330
437
437
546
546
601
EFFICIENCY at 75% load
93,7
94,1
93,8
93,8
94,2
94,2
94,6
VOLTAGE REGULATION SYSTEM
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
2950
3300
3300
3300
3500
3500
3500
WIDTH mm
1300
1400
1400
1400
1500
1500
1500
HEIGHT mm
1750
1887
1917
1917
2120
2120
2120
WEIGHT Kg
2110
2580
3050
3050
3620
3620
3620
FUEL TANK CAPACITY L
460
636
636
636
636
636
636
RUNNING TIME at 75% PRP h
11,2
13,13
11,14
10,17
9,34
8,37
7,31
Panels
- ACP n° 8, pag. 79
23
INDUSTRIAL GENERATORS SOUNDPROOF GBL 30d-42d
GBL SERIES
THE MULTIPURPOSE
GENERATOR I
This range has been designed to meet particular market needs.
The most suitable application is on construction sites, where
durability and reliability are required to supply constant power
to applications such as lighting, cranes, concrete mixers and
conveyor belts. With low noise emissions, they are also suitable
for open air activities, such as shows or sporting events.
ALSO FOR BIODIESEL 100%
Accessories
Load Transfer Switch Panel (LTS) for ACP versions
Single phase version
Light Tower
Site trailer
Road trailer-rigid bar
Engine electronic governor
Coolant pre-heating system (for automatic start)
Stacking option while warehousing
Visual fuel level
External fuel refilling
Single fluid for cooling and lubrication
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GUARANTEED SOUND POWER LEVEL LWA dB(A)
GBL30d
GBL42d
three phase
three phase
24,0/30,0
23,2/29,0
400
50
3
33,0/41,3
31,5/39,3
400
50
3
Deutz
F4M2011
Diesel
4 in line
3110
Natural
Oil
Electric
1500
Mechanical
29
27,6
10
NA
5,32
7,09
12
Deutz
BF4M2011
Diesel
4 in line
3110
Turbo
Oil
Electric
1500
Mechanical
38,2
36,4
10
NA
7,05
9,4
12
Stamford
BCI 184F
4
30
85,8
Electronic
Stamford
BCI 184J
4
45
86,6
Electronic
2000
920
1300
848
51
9,59
67
92
2000
920
1300
942
51
7,23
67
92
Panels
- MCP n° 5, pag. 79
- ACP n° 6, pag. 79
25
INDUSTRIAL GENERATORS SOUNDPROOF GSL 30d-42d
GSL SERIES
RENTAL ENERGY I
This range of generators is suitable for any application.
They have all the features associated with PRAMAC
Generators; low noise, security, greatly extended running
time and versatility in all applications. The perfect choice
for rental.
ALSO FOR BIODIESEL 100%
FULLY BUNDED BASEFRAME
Accessories
Galvanized skid base frame with integrated driptray and fork lift channels
Site trailer
Road trailer-rigid bar
Socket kit
Engine electronic governor
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Rental Kit
Single lifting eye
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Single phase version
Light Tower
Rental kit
Controlled exhaust emissions
Detachable canopy panels
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GUARANTEED SOUND POWER LEVEL LWA dB(A)
GSL30d
GSL42d
three phase
three phase
24,0/30,0
23,2/29,0
400
50
3
33,0/41,3
31,5/39,3
400
50
3
Deutz
F4M2011
Diesel
4 in line
3110
Natural
Oil
Electric
1500
Mechanical
29,00
27,60
10,00
NA
5,32
7,09
12
Deutz
BF4M2011
Diesel
4 in line
3110
Turbo
Oil
Electric
1500
Mechanical
38,20
36,40
10,00
NA
7,05
9,40
12
Stamford
BCI 184F
4
30,00
85,80
Electronic
Stamford
BCI 184J
4
45,00
86,60
Electronic
2200
920
1300
952
78
14,7
64
89
2000
920
1300
1024
78
11,0
64
89
Panels
- MCP Analogue n° 7, pag. 79
- ACP n° 9, pag. 80
- MCP Digital n° 13, pag. 81
27
INDUSTRIAL GENERATORS SOUNDPROOF GBW15-45p/y
GBW SERIES
FRIENDLY GENERATION
Family with optimized features specially focused to meet the needs of
low investment applications. Generators of reduced dimensions and weight
making it easy to transport and store. Ideal for rental use.
Accessories
Single phase version
Coolant pre-heating system (for automatic start)
Site trailer
Road trailer-rigid bar
Load Transfer Switch Panel (LTS) for ACP versions
Long autonomy fuel tanks
Pneumatic arm
Support legs welded to baseframe
Canopy lock
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GUARANTEED SOUND POWER LEVEL LWA dB(A)
GBW15p
GBW15y
GBW22p
GBW22y
GBW30p
GBW30y
GBW45p
GBW45y
three phase
three phase
three phase
three phase
three phase
three phase
three phase
three phase
11,1/13,8
10,0 /12,7
400
50
3
11,1/13,8
10,4/13,0
400
50
3
16,1/20,1
15,2/19,0
400
50
3
16,1/20,1
15,2/19,0
400
50
3
24,0/30,0
23,2/29,0
400
50
3
26,4/33,0
26,0/32,5
400
50
3
36,0/45,0
35,2/44,0
400
50
3
36,0/45,0
35,2/44,0
400
50
3
Perkins
403C-15G
Diesel
3 in line
1496
Natural
Water
Electric
1500
Mechanical
13,3
12,0
6,0
6,0
2,7
3,6
12
Yanmar
3TNV88
Diesel
3 in line
1642
Natural
Water
Electric
1500
Mechanical
14,5
13,2
6,7
2,0
2,8
3,7
12
Perkins
404C-22G
Diesel
4 in line
2216
Natural
Water
Electric
1500
Mechanical
20,3
18,4
10,6
7,0
3,8
5,1
12
Yanmar
4TNV88
Diesel
4 in line
2190
Natural
Water
Electric
1500
Mechanical
19,5
17,7
10,6
7,0
3,8
5,1
12
Perkins
1103A-33G
Diesel
3 in line
3300
Natural
Water
Electric
1500
Mechanical
30,4
27,7
7,9
10,2
5,1
6,8
12
Yanmar
4TNV98
Diesel
4 in line
3319
Natural
Water
Electric
1500
Mechanical
37,5
34,1
10,5
4,2
6,1
8,1
12
Perkins
1103A-33TG1
Diesel
3 in line
3300
Natural
Water
Electric
1500
Mechanical
45,6
41,3
7,9
10,2
7,8
10,4
12
Yanmar
4TNV98T
Diesel
4 in line
3319
Natural
Water
Electric
1500
Mechanical
45,5
41,4
10,5
4,2
8,7
11,6
12
Linz
E1S13 M/4/19
4
20,1
86,5
Compound
Stamford
BCI 184F
4
30,0
85,8
Electronic
Stamford
BCI 184G
4
33,0
85,8
Electronic
Stamford
BCI 184J
4
45,0
86,6
Electronic
Stamford
BCI 184J
4
45,0
86,6
Electronic
1600
870
1072
493
51
13,3
68
93
2000
920
1300
875
51
10,0
68
93
2000
920
1300
758
51
8,4
67
92
2000
920
1300
960
51
6,5
66
91
2000
920
1300
848
51
5,9
67
92
Linz
Linz
Linz
E1S13 M/4/13 E1S13 M/4/13 E1S13 M/4/19
4
4
4
13,8
13,8
20,1
85,4
85,4
86,5
Compound
Compound
Compound
1600
855
1072
560
51
18,7
71
96
1600
855
1072
430
51
18,3
68
93
1600
870
1072
565
51
13,3
70
95
Panels
- MCP n° 5, pag. 79
- ACP n° 6, pag. 79
29
INDUSTRIAL GENERATORS SOUNDPROOF GBW 65p-110p
GBW SERIES
THE MULTIPLE PURPOSE
GENERATOR II
Compliant with noise and exhaust emissions regulations, this middle power
rating range is designed to meet every kind of application where reliability
without any specific or special requirements is needed.
Accessories
Single phase version
Coolant pre-heating system (for automatic start)
Socket kit of 5 plugs
Site trailer
Road trailer-rigid bar
Load Transfer Switch Panel (LTS) for ACP versions
Control panel behind lockable door
Socket kit available
Fuel filter
Oil drain pipe
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GUARANTEED SOUND POWER LEVEL LWA dB(A)
GBW65p
GBW80p
GBW110p
three phase
three phase
three phase
50,0/63,0
48,0/60,0
400
50
3
64,0/80,0
62,0/77,0
400
50
3
88,0/110,0
80,0/100,0
400
50
3
Perkins
1103A-33TG2
Diesel
3 in line
3300
Turbo
Water
Electric
1500
Mechanical
59,3
53,8
7,9
10,2
11,0
14,0
12
Perkins
1104A-44TG2
Diesel
4 in line
4400
Turbo
Water
Electric
1500
Mechanical
79,1
71,9
8,0
13,0
14,0
19,0
12
Perkins
1104C-44TAG2
Diesel
4 in line
4410
Turbo, CAC
Water
Electric
1500
Electrical
98,0
89,0
8,0
13,0
22,0
30,0
12
Stamford
UCI 274 C
4
63,00
88,80
Electronic
Stamford
UCI 224 E
4
80,00
89,90
Electronic
Stamford
UCI 224 F
4
110,0
90,3
Electronic
2380
1000
1301
1155
120
11,0
71
96
2380
1000
1301
1285
120
8,0
71
96
2380
1000
1301
1480
120
5,0
71
96
Panels
- MCP Analogue n° 10, pag. 80
- ACP n° 11, pag. 80
- MCP Extended n° 14, pag. 81
31
INDUSTRIAL GENERATORS SOUNDPROOF GSW 15p-22p
GSW SERIES
COMPACT ENERGY I
This series provides the most professional way
to fulfill small power requirements
with highest reliability and excellent performance.
Most popular range for residential areas
and telecommunication sites.
FULLY BUNDED BASEFRAME
Accessories
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Single phase version
Rental kit
Galvanized skids frame with fork lift channels
Site trailer
Road trailer-rigid bar
Socket kit
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Detachable lifting eye
Galvanized skids
Lockable door handles
Rental optionals available
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GUARANTEED SOUND POWER LEVEL LWA dB(A)
GSW15p
GSW22p
three phase
three phase
11,5/14,3
10,3/12,9
400
50
3
17,1/21,4
15,5/19,4
400
50
3
Perkins
403C-15G
Diesel
3 in line
1496
Natural
Water
Electric
1500
Mechanical
13,30
12,00
6,00
5,98
2,72
3,63
12
Perkins
404C-22G
Diesel
3 in line
2215
Natural
Water
Electric
1500
Mechanical
20,30
18,40
10,60
5,98
3,98
5,30
12
Mecc-Alte
ECO 3 2L
4
15,00
86,80
Electronic
Stamford
BCI 184E
4
22,50
84,20
Electronic
1800
830
1300
700
78
28,7
61
86
1800
830
1310
810
78
19,6
61
86
Panels
- MCP Analogue n° 7, pag. 79
- ACP n° 9, pag. 80
- MCP Digital n° 13, pag. 81
33
INDUSTRIAL GENERATORS SOUNDPROOF GSW 15d-22d
GSW SERIES
COMPACT ENERGY II
This range is designed for the most competitive markets which
require the ability to run many different applications with small
power demands. The wide range of accessories, small
dimensions, long running and rental versions make them very
attractive products.
FULLY BUNDED BASEFRAME
Accessories
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Single phase version
Rental kit
Galvanized skids frame with fork lift channels
Site trailer
Road trailer-rigid bar
Socket kit
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Noise attenuation material
Wide range of accesories
Manual oil drain pump
Terminal block
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GUARANTEED SOUND POWER LEVEL LWA dB(A)
GSW15d
GSW22d
three phase
three phase
12,0/15,0
11,5/14,3
400
50
3
16,9/21,1
16,1/20,1
400
50
3
Deutz
D2009L03
Diesel
3 in line
1718
Natural
Water
Electric
1500
Mechanical
15,60
14,80
5,80
NA
2,84
3,79
12
Deutz
D2009L04
Diesel
4 in line
2290
Natural
Water
Electric
1500
Mechanical
20,00
19,10
7,50
NA
3,91
5,21
12
Mecc-Alte
ECO 3 2L
4
15,00
86,80
Electronic
Stamford
BCI 184E
4
22,50
84,20
Electronic
1800
830
1300
785
78
20
66
91
1800
830
1300
785
78
20
66
91
Panels
- MCP Analogue n° 7, pag. 79
- ACP n° 9, pag. 80
- MCP Digital n° 13, pag. 81
35
INDUSTRIAL GENERATORS SOUNDPROOF GSW 65d-170d
GSW SERIES
RENTAL ENERGY II
Specially designed for the most demanding power rating in general
applications, ideal for rental operators. With a modern design, low noise
levels and versatile accessories, this family is easily adaptable to fit
any particular specification.
FULLY BUNDED BASEFRAME
Accessories
Engine electronic governor
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Exceptional water cooled engines selection
Lockable door handles
Single phase version
Rental kit
Socket kit
Galvanized baseframe
Site trailer
Road trailer-rigid var
Detachable canopy panels
Fork lifts easy transportation
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GUARANTEED SOUND POWER LEVEL LWA dB(A)
(1)
GSW65d
GSW80d
GSW110d
GSW145d (1)
GSW170d
three phase
three phase
three phase
three phase
three phase
50/63
46/58
400
50
3
63/78
59/74
400
50
3
86/108
82/102
400
50
3
113/142
108/135
400
50
3
134/167
127/159
400
50
3
Deutz
BF4M2012 G2
Diesel
4 in line
4040
Turbo
Water
Electric
1500
Mechanical
58
52
8,5
15,9
10,26
13,68
12
Deutz
BF4M2012C
Diesel
4 in line
4040
Turbo, CAC
Water
Electric
1500
Mechanical
70
66,1
8,5
17,9
11,74
15,66
12
Deutz
BF4M1013EC
Diesel
4 in line
4760
Turbo, CAC
Water
Electric
1500
Mechanical
96,1
91,1
11
19,7
16,67
22,23
12
Deutz
BF6M1013E
Diesel
6 in line
7150
Turbo
Water
Electric
1500
Mechanical
123,8
117,8
20
23,1
21,88
29,17
12
Deutz
BF6M1013EC
Diesel
6 in line
7150
Turbo, CAC
Water
Electric
1500
Mechanical
145,1
138,1
20
23,1
24,54
32,72
12
Stamford
UCI 224E
4
63
88,8
Electronic
Stamford
UCI 224F
4
80
89,9
Electronic
Stamford
UCI 274C
4
110
90,3
Electronic
Stamford
UCI 274E
4
150
91,7
Electronic
Stamford
UCI 274F
4
175
92,3
Electronic
2710
1180
1535
1300
340
33,14
70
95
2710
1180
1535
1460
340
28,95
70
95
3000
1150
1680
1900
340
20,39
72
97
3400
1250
1680
2180
340
15,54
71
96
3400
1250
1680
2250
340
13,86
71
96
This Generator is normally intended to be used for industrial application only. In this case, its engine would not have to comply with EU 97/68/EC Stage II (EU2007)
Directive (no need for subsequent modifications and/or integrations).
Panels
- MCP Analogue n° 7, pag. 79
- ACP n° 9, pag. 80
- MCP Digital n° 12, pag. 80
37
INDUSTRIAL GENERATORS SOUNDPROOF GSW 195d-220d
GSW SERIES
THE FULL EQUIP POWER
This range of generators includes a complete instrumentation panel, which
offers maximum protection and the highest endurance, making them suitable
for many high demanding activities, such as rental, telecommunications,
UPS systems and industrial applications.
FULLY BUNDED BASEFRAME
Accessories
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Large doors for easy maintenance
Different avaibility of panels
Rental kit
Site trailer
Road trailer-rigid bar
Galvanized skids
Socket kit
Higher quality components
Wide range of accesories
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GUARANTEED SOUND POWER LEVEL LWA dB(A)
GSW195d
GSW220d
three phase
three phase
155/194
149/186
400
50
3
176/220
166/208
400
50
3
Deutz
BF6M1013FCP G2
Diesel
6 in line
7150
Turbo intercooler
Water
Electric
1500
Electronic
178,6
161,6
20
27,3
32,9
43,86
24
Deutz
BF6M1013FCP G3
Diesel
6 in line
7150
Turbo intercooler
Water
Electric
1500
Electronic
196,6
178,6
20
27,3
36,84
49,12
24
Stamford
UCI 274G
4
194
92,4
Electronic
Stamford
UCI 274H
4
220
93,3
Electronic
3400
1250
2070
2700
340
10,3
70
95
3400
1250
2070
2700
340
9,2
70
95
Panels
- MCP Analogue n° 7, pag. 79
- ACP n° 9, pag. 80
- MCP Digital n° 12, pag. 80
39
INDUSTRIAL GENERATORS SOUNDPROOF GSW 530d-560d
GSW SERIES
SUITABLE FOR SPECIFIC
APPLICATIONS
These generators are designed for stand by applications, and fulfill the demand
for “silent” power. Sturdy and reliable, like all PRAMAC machines, the “silent”
power is guaranteed to fully conform to directive 2000/14/EC, on
environmental noise emissions.
LEAK PROOF TRAY
Accessories
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Residential silencer
Innovated air grid design
Connection kit for communication via Modem / GSM (only for automatic versions)
Socket kit
Fully bunded baseframe
High performance engine
with canbus communication system
Terminal board load connection
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MODEL
TYPE
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
DISPLACEMENT cc
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MODEL
TYPE
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GUARANTEED SOUND POWER LEVEL LWA dB(A)
GSW530d
GSW560d
three phase
three phase
422/528
367/459
400
50
3
437/546
407/509
400
50
3
Deutz
Deutz
BF8M1015C G2
BF8M1015CP
Diesel
Diesel
8V
8V
15900
15900
Turbocharged intercooler Turbocharged intercooler
Water
Water
Electric
Electric
1500
1500
Electronic
Electronic
449,7
475,9
391,3
433,9
45
45
102
116
72,32
85,62
96,43
114,16
24
24
Mecc-Alte
ECO40 3S/4
4
546
94,2
Electronic
Mecc-Alte
ECO40 3S/4
4
546
94,2
Electronic
4200
1860
2250
4500
636
8,79
73
98
4200
1860
2250
4650
636
7,43
75
100
Panels
- ACP n° 8, pag. 79
41
INDUSTRIAL GENERATORS SOUNDPROOF GSW 275V-590V
GSW SERIES
SILENT POWER
FOR PUBLIC AND
INDUSTRIAL USES
Low noise emissions (conforming to directive 2000/14/EC,
related to environmental noise emissions), conformity
to gas emission laws and high security (lockable panels,
fireproof canopy) make these sets ideal for any public
or industrial application, such as hospitals,
supermarkets, factories.
LEAK PROOF TRAY
Accessories
Coolant pre-heating system (for automatic start)
Automatic fuel transfer pump
Load Transfer Switch Panel (LTS) for ACP versions
Extra Automatic Load Transfer Switch (ATS) panel for ACP+LTS versions
Connection kit for communication via Modem / GSM (only for automatic versions)
Lifting structure
Fireproof noise attenuation material
Socket kit
Fully bunded baseframe
Rental kit (only for GSW275)
Galvanized skids (only for GSW275)
Side trailer
Exhaust emissions regulations compliant
Set of documentation available
GSW275V
GSW330V
GSW415V
GSW450V
GSW510V
GSW560V
GSW590V
three phase
three phase
three phase
three phase
three phase
three phase
three phase
GENERATING SET
STAND BY POWER LTP kW/kVA
220/275
264/330
331/414
350/437
406/507
437/546
481/601
PRIME POWER PRP kW/kVA
202/252
252/315
302/378
329/411
369/461
404/505
457/571
VOLTAGE Volt
400
400
400
400
400
400
400
FREQUENCY Hz
50
50
50
50
50
50
50
PHASES
3
3
3
3
3
3
3
ENGINE
MODEL
Volvo
Volvo
Volvo
Volvo
Volvo
Volvo
Volvo
TYPE
TAD734GE
TAD941GE
TAD1241GE
TAD1242GE
TAD1640GE
TAD1641GE
TAD1642GE
FUEL
Diesel
Diesel
Diesel
Diesel
Diesel
Diesel
Diesel
NUMBER AND DISPOSITION OF CYLINDERS
6 in line
6 in line
6 in line
6 in line
6 in line
6 in line
6 in line
DISPLACEMENT cc
7150
9360
12130
12130
16120
16120
16120
ASPIRATION
Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler
COOLING SYSTEM
Water
Water
Water
Water
Water
Water
Water
STARTING SYSTEM
Electric
Electric
Electric
Electric
Electric
Electric
Electric
SPEED rpm
1500
1500
1500
1500
1500
1500
1500
SPEED GOVERNOR
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
STAND BY POWER LTP kW
241
320
354
387
432
473
536
PRIME POWER PRP kW
216
290
323
352
393
430
485
LUBE OIL CAPACITY (MAX) L
29
35
35
35
48
48
48
COOLANT CAPACITY (MAX) L
32
41
44
44
93
93
93
FUEL CONSUMPTION at 75% PRP L/h
39,29
48,45
57,1
62,54
68,07
76,02
87,04
FUEL CONSUMPTION at 100% PRP L/h
52,38
64,61
76,14
83,39
90,76
101,36
116,05
ELECTRICAL CIRCUIT Volt
24
24
24
24
24
24
24
ALTERNATOR
MODEL
Mecc-Alte
Mecc-Alte
Mecc-Alte
Mecc-Alte
Mecc-Alte
Mecc-Alte
Mecc-Alte
TYPE
ECO38 1L N4
ECO38 2L N4
ECO40 1S/4
ECO40 1S/4
ECO40 3S/4
ECO40 3S/4
ECO40 1L/4
POLES
4
4
4
4
4
4
4
STAND BY 163/27°C rating - LTP kVA
275
330
437
437
546
546
601
EFFICIENCY at 75% load
93,7
94,1
93,8
93,8
94,2
94,2
94,6
VOLTAGE REGULATION SYSTEM
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
OVERALL DIMENSIONS AND WEIGHT
LENGTH mm
3550
3950
3950
3950
4400
4400
4400
WIDTH mm
1360
1460
1460
1460
1560
1560
1560
HEIGHT mm
2016
2095
2095
2095
2250
2250
2250
WEIGHT Kg
2725
3200
3760
3760
4495
4495
4900
FUEL TANK CAPACITY L
460
636
636
636
636
636
636
RUNNING TIME at 75% PRP h
11,2
13,13
11,14
10,17
9,34
8,37
7,31
NOISE PRESSURE LEVEL at 7 mt dB(A)
72
72
72
72
73
74
75
GUARANTEED SOUND POWER LEVEL LWA dB(A)
97
97
97
97
98
99
100
Panels
- ACP n° 8, pag. 79
43
CUSTOMISED SOLUTIONS
Customised solution is the natural result of the knowledge acquired by PRAMAC group
in the power generation field, and of the growth of which has contributed to strengthening
the Group’s consolidated knowledge.
Today, the division specialises in the production of a wide and versatile range of generators
from 6 to 2500 kVA, able to satisfy all applications and requirements.
Commercial agreements with some of the most important suppliers in the industry guarantee
quality, reliability, and durability for all our products and solutions.
After a preliminary study phase, all models are carefully designed to meet the highest technical
and safety standards, demanded by the market and the most important of our partners:
the customer.
The Power Engineering division has the experience and the technical know-how
to develop solutions to meet every type of request, no matter how particular or specific.
Developing solutions requires capacity analysis, project management,
project realisation - following customer requierments and all necessary technical
and safety standards.
PRAMAC have the capability to provide a complete solution according to each market demand
and request.
Turnkey installations
Our specialised staff are able to study and offer turnkey projects for all proposed machines,
and to cooperate with the development of the complete project, depending on the agreed
technical specifications and terms of reference.
Control Panels
All the machines can be equipped with manual, automatic ACP or AMF control panels,
as well as parallel panels between two or more generators and parallel with the mains.
Other options can be studied by our Technical office.
Sound proof canopies and Containers
The generators can be fitted with soundproof canopies or certified containers
with high quality finishing and appearance, to satisfy all requirements.
Soundproof versions can be equipped with internal lighting systems (standard in containers),
for easy and safe maintenance.
Additional electric sockets are also available to allow use of external tools.
Customisation
All generators are produced in either a standard or customised configuration,
according to the customer’s requirements.
Each machine is also designed to meet the installation requirements.
Applications
Utilities
Deregulation and privatisation are on the agendas of all countries.
The raising of barriers to the energy market is an excellent opportunity
to find alternative sources to the National Power Supply companies.
Public and Civil Services
Applications for hospitals, highways, public transports, medical centres.
Constructions sites
Production of energy in construction sites to satisfy the demand of electric power
in locations not connected to a main power supply.
Industrial field
The provision of a constant supply of electric energy,
necessary to provide continuity of industrial processes.
Communications
Guaranteed provision of a continuous supply of power,
available during possible interruption, to assure services, data and devices integrity.
Agricultural
Power supply available for any application.
Residential applications
Peace of mind during power outages.
CUSTOMISED SOLUTIONS CUMMINS-MITSUBISHI
GPW SERIES
SPECIAL SOLUTIONS
The GPW series are special generating solutions, produced to
order, that can be adapted to our customer's specific requirements.
Detailed specifications of the control panels are given at the end
of this chapter (p. 52).
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
NOMINAL VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MANUFACTURER
MODEL
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
TOTAL DISPLACEMENT cc
AIR INTAKE
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MANUFACTURER
MODEL
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH (OPEN SET - SOUNDPROOF) mm
WIDTH (OPEN SET - SOUNDPROOF) mm
HEIGHT (OPEN SET - SOUNDPROOF) mm
WEIGHT (OPEN SET - SOUNDPROOF) Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GPW630
GPW810
GPW940
GPW1030
536/670
507/634
400
50
3Y
699/874
649/811
400
50
3Y
813/1016
750/937
400
50
3Y
911/1139
825/1031
400
50
3Y
Cummins
Cummins
Cummins
Cummins
VTA28 G5
QSK23G3
QST30G3
QST30G4
Diesel
Diesel
Diesel
Diesel
12 a V
6 in line
12 a V
12 a V
28000
23150
30480
30480
Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler
Electric
Electric
Electric
Electric
1500
1500
1500
1500
Electronic
Electronic
Electronic
Electronic
590
747
875
951
538
682
786
861
68
103
154
154
132
104
121
139
151
140
161
184
202
24
24
24
24
Mecc-Alte
ECO 40 1,5L/4
4
670
94,6
Electronic
Mecc-Alte
ECO 43 1SN
4
874
95,3
Electronic
Mecc-Alte
ECO 43 2SN
4
1016
95,7
Electronic
Mecc-Alte
ECO 43 1LN
4
1201
96
Electronic
3650 - 5575
1500 - 1870
2300 - 2620
6388 - 7227
120
1,2
- / 70
4450 - 6550
2250 - 2400
2300 - 3200
6901 - 9589
120
1,0
- / 70
4300 - 7050
2000 - 2400
2450 - 3500
7952 - 10439
120
0,9
- / 70
4300 - 7050
2000 - 2400
2450 - 3500
8106 - 10772
120
0,8
- / 70
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
NOMINAL VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MANUFACTURER
MODEL
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
TOTAL DISPLACEMENT cc
AIR INTAKE
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MANUFACTURER
MODEL
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH (OPEN SET - SOUNDPROOF) mm
WIDTH (OPEN SET - SOUNDPROOF) mm
HEIGHT (OPEN SET - SOUNDPROOF) mm
WEIGHT (OPEN SET - SOUNDPROOF) Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GPW1290
GPW1360
GPW1720
GPW1900
GPW2030
1136/1420
1037/1296
400
50
3Y
1136/1420
1086/1358
400
50
3Y
1416/1770
1376/1720
400
50
3Y
1555/1944
1490/1863
400
50
3Y
1814/2268
1626/2033
400
50
3Y
Mitsubishi
Mitsubishi
Mitsubishi
Mitsubishi
Mitsubishi
S12R-PTA
S12R-PTA2
S16R-PTA
S16R-PTA2
S16R-PTAA2
Diesel
Diesel
Diesel
Diesel
Diesel
12 a V
12 a V
16 a V
16 a V
16 a V
49030
49030
65370
65370
65370
Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler
Electric
Electric
Electric
Electric
Electric
1500
1500
1500
1500
1500
Electronic
Electronic
Electronic
Electronic
Electronic
1190
1285
1590
1740
1895
1080
1165
1450
1580
1684
180
180
230
230
230
198
213
259
291
305
264
284
346
388
407
24
24
24
24
24
Mecc-Alte
ECO 43 2LN
4
1420
96,2
Electronic
Mecc-Alte
ECO 43 2LN
4
1420
96,2
Electronic
Stamford
PI7D
4
1770
96,2
Electronic
Mecc-Alte
ECO 46 2S
4
1944
96,5
Electronic
Mecc-Alte
ECO46 1L
4
2268
96,8
Electronic
4400 - 7410
2000 - 2400
2300 - 3800
10736 - 12881
120
0,6
- / 70
4400 - 7410
2000 - 2400
2300 - 3800
11234 - 13379
120
0,6
- / 70
5175 - 7980
2000 - 2400
2550 - 3800
12352 - 14667
120
0,5
- / 70
5250 - 7980
2000 - 2400
2550 - 3800
14056 - 17221
120
0,4
- / 70
5950 - 7980
2150 - 2400
2800 - 3800
14247 - 17412
120
0,4
- / 70
47
CUSTOMISED SOLUTIONS MTU
GPW SERIES
SPECIAL SOLUTIONS
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
NOMINAL VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MANUFACTURER
MODEL
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
TOTAL DISPLACEMENT cc
AIR INTAKE
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MANUFACTURER
MODEL
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH (OPEN SET - SOUNDPROOF) mm
WIDTH (OPEN SET - SOUNDPROOF) mm
HEIGHT (OPEN SET - SOUNDPROOF) mm
WEIGHT (OPEN SET - SOUNDPROOF) Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GPW650
GPW720
GPW830
GPW980
GPW1025
536/670
510/638
400
50
3Y
588/735
560/700
400
50
3Y
699/874
656/820
400
50
3Y
813/1016
739/924
400
50
3Y
899/1123
812/1015
400
50
3Y
MTU
MTU
MTU
MTU
MTU
12V2000G23
12V2000G63
16V2000G23
16V2000G63
18V2000G63
Diesel
Diesel
Diesel
Diesel
Diesel
12 a V
12 a V
16 a V
16 a V
18 a V
23880
23880
31840
31840
35800
Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler
Electric
Electric
Electric
Electric
Electric
1500
1500
1500
1500
1500
Electronic
Electronic
Electronic
Electronic
Electronic
598
664
762
856
938
541
601
690
775
848
82
82
110
110
130
174
180
200
220
230
93
102
118
134
150
124
136
157
178
200
24
24
24
24
24
Mecc-Alte
ECO 40 1,5L/4
4
670
94,6
Electronic
Mecc-Alte
ECO 40 2L/4
4
735
94,7
Electronic
Mecc-Alte
ECO 43 1SN
4
874
95,3
Electronic
Mecc-Alte
ECO 43 2SN
4
1016
95,7
Electronic
Mecc-Alte
ECO 43 1LN
4
1201
96
Electronic
3860 - 5575
1580 - 1870
2070 - 2620
5758 - 7356
120
1,3
- / 70
4067 - 5575
1580 - 1870
2070 - 2620
6069 - 7667
120
1,2
- / 70
4398 - 6550
1752 - 1900
2210 - 3200
6942 - 9810
120
1,0
- / 70
4398 - 6550
1752 - 1900
2210 - 3200
7144 - 10012
120
0,9
- / 70
4591 - 7050
1752 - 2000
2451 - 3500
7840 - 10813
120
0,8
- / 70
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
NOMINAL VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MANUFACTURER
MODEL
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
TOTAL DISPLACEMENT cc
AIR INTAKE
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MANUFACTURER
MODEL
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH (OPEN SET - SOUNDPROOF) mm
WIDTH (OPEN SET - SOUNDPROOF) mm
HEIGHT (OPEN SET - SOUNDPROOF) mm
WEIGHT (OPEN SET - SOUNDPROOF) Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GPW1660
GPW1860
GPW2110
GPW2320
GPW2600
1416/1770
1326/1658
400
50
3Y
1555/1944
1480/1850
400
50
3Y
1814/2268
1689/2111
400
50
3Y
2067/2583
1854/2317
400
50
3Y
2160/2700
2070/2588
400
50
3Y
MTU
MTU
MTU
MTU
MTU
12V4000G23
12V4000G63
16V4000G23
16V4000G63
20V4000G23
Diesel
Diesel
Diesel
Diesel
Diesel
12 a V
12 a V
16 a V
16 a V
20 a V
57200
57200
76300
76300
95400
Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler
Electric
Electric
Electric
Electric
Electric
1500
1500
1500
1500
1500
Electronic
Electronic
Electronic
Electronic
Electronic
1535
1710
1915
2135
2390
1380
1535
1748
1915
2170
260
260
290
290
390
335
335
430
430
240
266
304
333
367
320
355
406
445
489
24
24
24
24
24
Stamford
PI7D
4
1770
96,2
Electronic
Mecc-Alte
ECO 46 2S
4
1944
96,5
Electronic
Mecc-Alte
ECO 46 1L
4
2268
96,8
Electronic
Mecc-Alte
ECO 46 2L
4
2700
97
Electronic
Mecc-Alte
ECO 46 2L
4
2700
97
Electronic
4890 - 7550
2000 - 2200
2448 - 3550
12972 - 15117
120
0,5
- / 70
5677 - 8550
2286 - 2500
2790 - 3900
16165 - 18430
120
0,5
- / 70
5762 - 8550
2286 - 2500
2790 - 3900
16649 - 18914
120
0,4
- / 70
5762 - 8550
2286 - 2500
2790 - 3900
16649 - 18914
120
0,4
- / 70
6990 - 11380
2500 - 2500
3350 - 4500
18000 - 22300
120
0,3
- / 70
49
CUSTOMISED SOLUTIONS PERKINS
GPW SERIES
SPECIAL SOLUTIONS
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
NOMINAL VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MANUFACTURER
MODEL
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
TOTAL DISPLACEMENT cc
AIR INTAKE
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MANUFACTURER
MODEL
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH (OPEN SET - SOUNDPROOF) mm
WIDTH (OPEN SET - SOUNDPROOF) mm
HEIGHT (OPEN SET - SOUNDPROOF) mm
WEIGHT (OPEN SET - SOUNDPROOF) Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GPW655
GPW740
GPW800
GPW975
GPW1020
536/670
511/639
400
50
3Y
588/735
560/700
400
50
3Y
699/874
646/807
400
50
3Y
813/1016
780/975
400
50
3Y
907/1134
825/1031
400
50
3Y
Perkins
Perkins
Perkins
Perkins
Perkins
2806C-E18 TAG2
4006C-23 TAG2A
4006C-23 TAG3A
4008TAG2A
4008TAG2A
Diesel
Diesel
Diesel
Diesel
Diesel
6 in line
6 in line
6 in line
8 in line
8 in line
18100
22921
22921
30561
30561
Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler
Electric
Electric
Electric
Electric
Electric
1500
1500
1500
1500
1500
Electronic
Electronic
Electronic
Electronic
Electronic
599
685
760
947
947
542
620
679
861
861
55,5
113
113
166
166
61
105
105
162
162
96
109
124
158
167
128
145
166
211
222
24
24
24
24
24
Mecc-Alte
ECO 40 1,5L/4
4
670
94,6
Electronic
Mecc-Alte
ECO 40 2L/4
4
735
94,7
Electronic
Mecc-Alte
ECO 43 1SN
4
874
95,3
Electronic
Mecc-Alte
ECO 43 2SN
4
1016
95,7
Electronic
Mecc-Alte
ECO 43 1LN
4
1201
96
Electronic
3391 - 5075
1536 - 1870
2050 - 2620
4860 - 6410
120
1,3
- / 70
3960 - 6550
1706 - 2000
2131 - 3450
6193 - 8456
120
1,1
- / 70
3960 - 6550
1706 - 2000
2131 - 3450
6203 - 8456
120
1,0
- / 70
4830 - 7260
1868 - 2100
2494 - 3500
8004 - 9873
120
0,8
- / 70
4830 - 7160
1868 - 2100
2494 - 3500
8166 - 10105
120
0,7
- / 70
GENERATING SET
STAND BY POWER LTP kW/kVA
PRIME POWER PRP kW/kVA
NOMINAL VOLTAGE Volt
FREQUENCY Hz
PHASES
ENGINE
MANUFACTURER
MODEL
FUEL
NUMBER AND DISPOSITION OF CYLINDERS
TOTAL DISPLACEMENT cc
AIR INTAKE
STARTING SYSTEM
SPEED rpm
SPEED GOVERNOR
STAND BY POWER LTP kW
PRIME POWER PRP kW
LUBE OIL CAPACITY (MAX) L
COOLANT CAPACITY (MAX) L
FUEL CONSUMPTION at 75% PRP L/h
FUEL CONSUMPTION at 100% PRP L/h
ELECTRICAL CIRCUIT Volt
ALTERNATOR
MANUFACTURER
MODEL
POLES
STAND BY 163/27°C rating - LTP kVA
EFFICIENCY at 75% load
VOLTAGE REGULATION SYSTEM
OVERALL DIMENSIONS AND WEIGHT
LENGTH (OPEN SET - SOUNDPROOF) mm
WIDTH (OPEN SET - SOUNDPROOF) mm
HEIGHT (OPEN SET - SOUNDPROOF) mm
WEIGHT (OPEN SET - SOUNDPROOF) Kg
FUEL TANK CAPACITY L
RUNNING TIME at 75% PRP h
NOISE PRESSURE LEVEL at 7 mt dB(A)
GPW1250
GPW1320
GPW1500
GPW1700
GPW1850
1108/1385
1002/1253
400
50
3Y
1136/1420
1086/1358
400
50
3Y
1319/1649
1199/1499
400
50
3Y
1416/1770
1366/1707
400
50
3Y
1555/1944
1482/1852
400
50
3Y
Perkins
Perkins
Perkins
Perkins
Perkins
4012TWG2
4012-46TWG3A
4012TAG2A
4012-46 TAG3A
4016TAG1A
Diesel
Diesel
Diesel
Diesel
Diesel
12 a V
12 a V
12 a V
12 a V
16 a V
45842
45842
45842
45842
61123
Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler Turbocharged intercooler
Electric
Electric
Electric
Electric
Electric
1500
1500
1500
1500
1500
Electronic
Electronic
Electronic
Electronic
Electronic
1154
1263
1380
1563
1690
1044
1149
1254
1421
1537
178
178
178
178
237
210
240
235
210
316
191
201
225
264
281
255
268
300
352
375
24
24
24
24
24
Mecc-Alte
ECO 43 2LN
4
1420
96,2
Electronic
Mecc-Alte
ECO 43 2LN
4
1420
96,2
Electronic
Stamford
PI7C
4
1660
95,7
Electronic
Stamford
PI7D
4
1770
96,2
Electronic
Mecc-Alte
ECO 46 2S
4
1944
96,5
Electronic
4852 - 7410
1868 - 2100
2686 - 3700
10284 - 12150
120
0,6
- / 70
4962 - 7410
2265 - 2500
3046 - 4050
11019 - 13260
120
0,6
- / 70
4962 - 7410
2265 - 2500
3046 - 4050
11317 - 13558
120
0,5
- / 70
5620 - 7980
2150 - 2400
2720 - 3800
14136 - 16450
120
0,5
- / 70
5620 - 8970
2775 - 3000
3516 - 3820
14588 - 17750
120
0,4
- / 70
51
CUSTOMISED SOLUTIONS
LTS
COMMANDS
1) Motorized change over switchgear
integrated into the same device.
2) n° 3 positions selector switch, placed
on the front of the panel, which allows
selecting manually the following positions:
• AUTO: operating mode based
on the automatic logic control.
• MAINS: Mains power supply forcement.
• GENSET: Genset power supply forcement.
3) Manual pulley, placed on the own change
over contactors, for emergency
load transfer.
CONNECTIONS
1) Plinth row for connection from MCB
(main circuit breaker) to LTS panel.
2) Terminals board for power cables
connection (GENSET - MAINS - LOAD).
PROTECTION
1) Mechanically and electrically interlocked.
2) n° 2 visual LED's to show the contactors
position: MAINS - GENSET.
3) Mechanical degree of protection:
IP40 (external) and IP20 (internal).
ACP
DIGITAL INSTRUMENTATION
Genereting set voltage (3 phases)
Mains voltage
Generating set frequency
Generating set current (3 phases)
Battery voltage
Active power (kW)
Reactive power (kVAr)
Apparent power (kVA)
Power factor (cosϕ)
Start-counter
Active energy counter (kWh) no fiscal
Hours-counter
Oil pressure (optional)
Engine coolant temperature (optional)
ALARMS SHOWN ON DISPLAY
Generator overload (derived from external
contact of MCB)
Running under conditions not reached
Generator under voltage
Generator over voltage
Generator under frequency
Generator over frequency
Maximum power
PROTECTIONS WITH SHUTDOWN
AUXILIARY SERVICES
Power reverse
High engine coolant temperature
Automatic battery charger
Closing of Mains contactor
Engine coolant preheating system power supply Low oil pressure
Overspeed (derived from generator frequency) or genset contactor failed
(single phase)
Stop failure
Engine over-crank
Acoustic alarm
No fuel
Programmable periodic test
Emergency stop
Genset report
COMMANDS AND OTHERS
Key operated mode selector switch
Engine start push button
Engine stop push button
Emergency stop push button
Acoustic alarm silencing push button
UP/DOWN push button for display selection
Accessories
EFO: extended capacity on base fuel tank
DPP: differential protection (available only with IV poles circuit breaker)
AFP: automatic refueling system
RES: residential silencer (only for open set version)
PHS: coolant preheating system (necessary for starting under ambient conditions < +10ºC)
TIF: IV poles circuit breaker instead of III poles
PROTECTIONS WITHOUT SHUTDOWN
Battery failure (maximum/minimum voltage)
Pre-alarm for low oil pressure (optional)
Pre-alarm for high engine coolant
temperature (optional)
Generator overload
(derived from external contact of MCB).
ITALY
AEM di Torino
AEM di Milano
ENEL Compartimento di Roma
ENEL Compartimento di Venezia
ENEL Compartimento di Firenze
ENEL Direzione Piemonte - V.D’Aosta
ENEL Compartimento di Cagliari
Teatro Regio di Torino
Teatro di Vicenza
Palazzo Borsa di Milano
Istituto Bocconi di Milano
Centro Direzionale Pirelli di Milano
Parco Gardaland (Verona)
Stadio Olimpico di Torino
Stadio Friuli di Udine
Stadio Ferraris di Genova
Stadio S. Paolo di Napoli
Autostrada Palermo Messina
Palazzo della Provincia di Firenze
Tribunale di Genova
IKEA di Ancona
LIDL di Pontedera (Pisa)
Università di Udine
ERG Raffinerie di Siracusa
Aeroporto di Comiso (Ragusa)
Aeroporto di Ciampino (Roma)
Ospedale Careggi di Firenze
Azienda Ospedaliero-Universitaria Pisana
Università Campus Biomedico di Roma
Ospedale “S. Andrea” di Roma
Ospedale “Spallanzani” di Roma
Policlinico di Bari
Fondazione CNAO di Pavia
Ospedale di Catania
Antenna SKYLOGIC (Torino)
FRANCE
Hôpital de La Châtre
Cafés Richard à Gennevilliers
Magasins Leader Price (Guadeloupe)
Station d’épuration d’Auray
Parkings de Bordeaux
Station de pompage de Pierrefite
Exaltis à La Défense
Buref à La Défense
Centre de rétention aéroport de Toulouse
Centre d’appel TRANSCOM à Roanne
Station d’épuration Canet en Roussillon
Usine PHOTOWATT à Bourgoin Jallieu
Others
AMENA (SPAIN)
MOBITEL (VIETNAM)
ERA (POLAND)
BALTON (SUDAN)
GRAMEEN PHONE (BANGLADESH)
SWITCH (SUDAN)
HOTEL RIU (BAHAMAS)
WAL MART (MEXICO)
GHANA TELECOM (GHANA)
STATOIL (NORWAY)
DHL LOGISTICS (Normanton UK)
CUSTOMISED SOLUTIONS
GCW UNITS
The GCW units are customised generators specially developed and produced
against specific requests of each customer.
The following project was developed for the STATOIL company in Norway.
Company Brief
Statoil is an integrated oil and gas company with substantial international
activities. It was created in 1972 when the Norwegian Parliament
decided to establish a state crude oil company, the STATOIL.
Its main activity consisted of the exploration, production, distribution,
refinery and sales of crude oil and its derivates,
operating alone or together with other companies.
Case Brief
Customized Generating Set for operating at very low temperatures.
The machine was placed inside a 25’ container, equipped with motorized louvers
and electric fans, to extract residual hot air generated by the engine,
as a self-standing heating system.
The engine is equipped with water and oil pre-heaters,
and an electric fan radiator installed in the external container space.
The fuel is pre-heated and supplied from an external tank,
through insulated pipes, making the installation suitable to work
in -20° C environments.
The automatic mains failure control panel is equipped with
a SIEMENS motorized circuit breaker.
Since the operation motor switch was not available for 690Vac,
a UPS was intentionally installed.
2896
265
2160
600
100
545
1055
375
2105
415
7620
5300
2896
GRIGIA MOTORIZZ
SU ASPIRAZIONE
ZOCCOLO H=110mm SOTTO EL.RADIATORE
119
A CURA DI PRAMAC
411
350 350 300 300
DATA SHEET
MAIN CHARACTERISTICS
MODEL NAME
COUNTRY
ENGINE
ALTERNATOR
POWER PRP kVA/kW
POWER LTP kVA/kW
VOLTAGE V
FREQUENCY Hz
NOISE PRESSURE LEVEL at 7 mt dB(A)
TANK CAPACITY L
LENGTH mm
325 275 300
GCW1560-50S (TORNADO 1500)
NORWAY
MTU 12V4000G61
STAMFORD HCI7F
1557/1245
1630/1304
690
50
85
External tank
7620
55
PORTABLE GENSET & POWER EQUIPMENT
ES SERIES
LONG RUN ENERGY
A class of petrol generators designed specifically for intensive
operations where performance power is demanded by professional
users over an extended period of time.
UP TO
12 HOURS
AUTONOMY
Equipment
OPTIONAL
Hourmeter (except ES5000 single phase, ES8000 single phase)
Transportation kit
Cover
STANDARD
Thermal protection
Oil guard system
Transportation kit
Cover
Sockets
Fuel tank
ES3000
ES4000
ES500
ES5000
ES8000
ES8000
single phase
petrol
single phase
petrol
three phase
petrol
single phase
petrol
three phase
petrol
single phase
petrol
THREE PHASE
(POWER LTP) kW/kVA
(POWER COP) kVA
SINGLE PHASE
(POWER LTP) kW/kVA
2,59/2,88
(POWER COP) kVA
2,45
POWER SPEC.
VOLTAGE Volt
230
FREQUENCY Hz
50
POWER FACTOR cosϕ
0,9
ENGINE
MODEL
Honda
TYPE
GX160
DISPLACEMENT cc
163
CYLINDER
1 inclination angle
POWER kW
3,6
ASPIRATION
Natural
COOLING SYSTEM
Air
STARTING SYSTEM
Recoil
CONSUMPTION
FUEL CONSUMPTION g/kWh
313
FUEL CONSUMPTION at 75% of load L/h
0,9
FUEL TANK CAPACITY L
11
RUNNING TIME at 75% of load h
11,8
NOISE EMISSION
GUARANTEED SOUND POWER LEVEL LWA dB(A)
96
NOISE PRESSURE LEVEL at 7 mt dB(A)
70
DIMENSIONS AND WEIGHT
LENGTH mm
623
WIDTH mm
409
HEIGHT mm
500
WEIGHT (DRY) Kg
41
SOCKET TYPE
2 SCHUKO
ALTERNATOR AND SOCKET PROTECTION
ELECTRIC PROTECTION
SOCKET PROTECTION
COP
LTP
IP23
IP 54
5,04/6,30
5,36
6,64/8,30
7,00
3,05/3,39
2,88
3,74/4,16
3,14
4,60/5,11
4,20
4,93/5,48
4,11
6,43/7,15
6,00
230
50
0,9
400/230
50
0,8/0,9
230
50
0,9
400/230
50
0,8/0,9
230
50
0,9
Honda
GX200
196
1 inclination angle
4,3
Natural
Air
Recoil
Honda
GX270
270
inclination angle
6,3
Natural
Air
Recoil
Honda
GX270
270
1 inclination angle
6,3
Natural
Air
Recoil
Honda
GX390
389
1 inclination angle
8,3
Natural
Air
Recoil
Honda
GX390
389
1 inclination angle
8,3
Natural
Air
Recoil
313
1,1
11
9,9
313
1,6
11
6,7
313
1,6
11
6,7
313
2,1
11
5,1
313
2,2
11
5,1
95
69
97
71
97
71
97
72
97
72
623
409
500
43
729
500
536
75
729
500
536
61
729
500
536
81
729
500
536
73
2 SCHUKO
SCHUKO
400V 16A
SCHUKO
230V 16A
SCHUKO
400V 16A
SCHUKO
230V 32A
IP23
IP 54
IP23
IP 44
IP23
IP 44
IP23
IP 44
IP23
IP 44
Continuous Power
Maximum Power
57
PORTABLE GENSET & POWER EQUIPMENT
S SERIES
THE COMPLETE PACKAGE
All the features of a top class generator: a powerful and economical engine,
a strong and modern design and a long-run easy filling fuel tank.
LWA
96 dB(A)
Equipment
STANDARD
Magneto Thermal protection
(except S3200, S5000 and S8000 single phase with thermal protection)
Oil guard system
Battery charger 12V-10A (except S3200, S12000)
OPTIONAL
Differential Protection (except S3200)*
Insulation Monitoring*
Automatic Voltage Regulator (AVR) (S5000, S8000 three phase only)
Automatic Mains Failure (AMF) (except S3200)
Remote Control (RSS) (except S3200)
Transportation kit
Lifting kit/Hook (except S3200, S12000)
* Includes Voltmeter, Hourmeter (except S3200)
Automatic mains failure
Remote start stop
Lifting kit
Manual transfer switch
S3200
S5000
S5000
S8000
S8000
S12000
S12000
single phase
petrol
three phase
petrol
single phase
petrol
three phase
petrol
single phase
petrol
three phase
petrol
single phase
petrol
THREE PHASE
(POWER LTP) kW/kVA
5,04/6,30
6,64/8,30
(POWER COP) kVA
5,36
7,00
SINGLE PHASE
(POWER LTP) kW/kVA
2,54/2,82
3,74/4,16
4,79/5,32
4,93/5,48
6,43/7,15
(POWER COP) kVA
2,40
3,14
4,10
4,11
6,00
POWER SPEC.
VOLTAGE Volt
230
400/230
230
400/230
230
FREQUENCY Hz
50
50
50
50
50
POWER FACTOR cosϕ
0,9
0,8/0,9
0,9
0,8/0,9
0,9
ENGINE
MODEL
Honda
Honda
Honda
Honda
Honda
TYPE
GX160
GX270
GX270
GX390
GX390
DISPLACEMENT cc
163
270
270
389
389
CYLINDER
1 inclination angle 1 inclination angle 1 inclination angle 1 inclination angle 1 inclination angle
POWER kW
3,6
6,3
6,3
8,3
8,3
ASPIRATION
Natural
Natural
Natural
Natural
Natural
COOLING SYSTEM
Air
Air
Air
Air
Air
STARTING SYSTEM
Recoil
Electric/Recoil
Electric/Recoil
Electric/Recoil
Electric/Recoil
CONSUMPTION
FUEL CONSUMPTION g/kWh
313
313
313
313
313
FUEL CONSUMPTION at 75% of load L/h
0,9
1,6
1,6
2,1
2,2
FUEL TANK CAPACITY L
11
18
18
18
18
RUNNING TIME at 75% of load h
11,8
11,0
11,0
8,4
8,4
NOISE EMISSION
GUARANTEED SOUND POWER LEVEL LWA dB(A)
96
97
97
97
97
NOISE PRESSURE LEVEL at 7 mt dB(A)
70
71
71
72
72
DIMENSIONS AND WEIGHT
LENGTH mm
623
842
842
842
842
WIDTH mm
409
523
523
523
523
HEIGHT mm
500
557
557
557
557
WEIGHT (DRY)** Kg
42
88
76
99
96
SOCKET TYPE
2 SCHUKO
SCHUKO
SCHUKO
SCHUKO
SCHUKO
400V 16A
230V 32A
400V 16A
230V 32A
ALTERNATOR AND SOCKET PROTECTION
ELECTRIC PROTECTION
SOCKET PROTECTION
COP
LTP
**
IP23
IP 54
IP23
IP 44
IP23
IP 44
IP23
IP 44
IP23
IP 44
11,14/13,92
11,83
8,27/9,19
6,94
10,69/11,88
10,00
400/230
50
0,8/0,9
230
50
0,9
Honda
GX620
614
2-V
13,5
Natural
Air
Electric
Honda
GX620
614
2-V
13,5
Natural
Air
Electric
313
3,5
24
6,9
313
3,5
24
6,9
96
70
96
70
960
641
667
165
960
641
667
162
SCHUKO
2 x 230V 16A
400V 16A
SCHUKO
230V 16A
230V 32A
IP23
IP 44
IP23
IP 44
Continuous Power
Maximum Power
On electric version +3/8 Kg to add
59
PORTABLE GENSET & POWER EQUIPMENT
S SERIES
THE YELDING PACKAGE
Showing the excellence of PRAMAC's professional equipment, this range
offers a robust package with a modern and economical diesel engine.
Equipment
OPTIONAL
Differential Protection (S9000 three phase only)
Insulation Monitoring
Voltmeter (S9000 only)
Hourmeter (S6000 only)
Automatic Mains Failure (AMF)
Remote Control (RSS)
Transportation kit
STANDARD
Magneto Thermal protection
(S9000 single phase thermal protection)
Oil Pressure Indicator (S9000 only)
Differential Protection (except S9000)
Voltmeter (except S9000)
Battery charger (except S9000)
Manual transfer switch
Remote start stop
Automatic mains failure
Transportation kit with folding handles
THREE PHASE
(POWER LTP) kW/kVA
(POWER COP) kVA
SINGLE PHASE
(POWER LTP) kW/kVA
(POWER COP) kVA
POWER SPEC.
VOLTAGE Volt
FREQUENCY Hz
POWER FACTOR cosϕ
ENGINE
MODEL
TYPE
DISPLACEMENT cc
CYLINDER
POWER kW
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
CONSUMPTION
FUEL CONSUMPTION g/kWh
FUEL CONSUMPTION at 75% of load L/h
FUEL TANK CAPACITY L
RUNNING TIME at 75% of load h
NOISE EMISSION
GUARANTEED SOUND POWER LEVEL LWA dB(A)
NOISE PRESSURE LEVEL at 7 mt dB(A)
DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT (DRY) Kg
SOCKET TYPE
ALTERNATOR AND SOCKET PROTECTION
ELECTRIC PROTECTION
SOCKET PROTECTION
•
COP
LTP
S4500
S6000
S6500
S9000
S9000
single phase
diesel
three phase
diesel
single phase
diesel
three phase
diesel
single phase
diesel
5,49/6,86
5,62
8,21/10,26
8,83
3,65/4,05
3,45
4,07/4,53
3,30
5,31/5,90
4,84
6,10/6,77
5,18
7,90/8,78
7,55
230
50
0,9
400/230
50
0,8/0,9
230
50
0,9
400/230
50
0,8/0,9
230
50
0,9
Yanmar
L70
296
1 Vertical
4,8
Natural
Air
Electric
Yanmar
L100
406
1 Vertical
6,9
Natural
Air
Electric
Yanmar
L100
406
1 Vertical
6,9
Natural
Air
Electric
Ruggerini
MD150
654
2 In line
10
Natural
Air
Electric
Ruggerini
MD150
654
2 In line
10
Natural
Air
Electric
272
1,0
3,5
3,5
272
1,4
5,5
4,0
272
1,4
5,5
4,0
260
2,0
24
12,0
260
2,0
24
12,0
•
•
•
•
•
•
•
•
•
•
810
450
500
81
830
490
570
108
830
490
570
99
970
600
690
148
970
600
690
141
SCHUKO
230V 16A
230V 32A
2 x SCHUKO
230V 16A
400V 16A
SCHUKO
230V 16A
230V 32A
SCHUKO
400V 16A
SCHUKO
230V 32A
IP23
IP 44
IP23
IP 44
IP21
IP 44
IP23
IP 44
IP23
IP 44
For fixed installation only
Continuous Power
Maximum Power
61
PORTABLE GENSET & POWER EQUIPMENT
SP SERIES
THE COMPLETE
PROTECTION
A premium range with insulation monitoring
and Automatic Voltage Regulator as standard.
All panels and alternators featuring IP54 protection.
IP 54
Equipment
OPTIONAL
Transportation kit
Lifting kit/Hook (SP8000 only)
STANDARD
Magneto Thermal protection
Oil guard system
Insulation Monitoring
Voltmeter (SP12000 only)
Hourmeter
Automatic Voltage Regulator (AVR)
Transportation kit
Lifting kit
IP54 isometer panel
Large fuel tank
THREE PHASE
(POWER LTP) kW/kVA
(POWER COP) kVA
SINGLE PHASE
(POWER LTP) kW/kVA
(POWER COP) kVA
POWER SPEC.
VOLTAGE Volt
FREQUENCY Hz
POWER FACTOR cosϕ
ENGINE
MODEL
TYPE
DISPLACEMENT cc
CYLINDER
POWER kW
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
CONSUMPTION
FUEL CONSUMPTION g/kWh
FUEL CONSUMPTION at 75% of load L/h
FUEL TANK CAPACITY L
RUNNING TIME at 75% of load h
NOISE EMISSION
GUARANTEED SOUND POWER LEVEL LWA dB(A)
NOISE PRESSURE LEVEL at 7 mt dB(A)
DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT (DRY) Kg
SOCKET TYPE
ALTERNATOR AND SOCKET PROTECTION
ELECTRIC PROTECTION
SOCKET PROTECTION
**
COP
LTP
SP8000
SP12000
three phase
petrol
three phase
petrol
7,06/8,82
6,75
11,07/13,84
11,76
5,24/5,82
3,96
7,31/9,13
7,76
400/230
50
0,8/0,9
400/230
50
0,8/0,9
Honda
GX390
389
1 inclination angle
8,3
Natural
Air
Electric/Recoil
Honda
GX620
614
2-V
13,5
Natural
Air
Electric
313
1,9
18
9,3
313
3,5
24
6,9
97
72
96
70
842
523
557
113
960
641
667
170
230V 16A
400V 16A
3 x SCHUKO
400V 16A
400V 32A
IP54
IP54
IP54
IP54
On electric version +3/8 Kg to add
Continuous Power
Maximum Power
63
PORTABLE GENSET & POWER EQUIPMENT
P SERIES
THE SILENT POWER I
SUPER
SILENCED
The ideal generator for use in residential areas or outside normal
working hours. These generators are equipped with first quality
components and complete instrumentation.
Equipment
OPTIONAL
Differential Protection
Insulation Monitoring
Automatic Mains Failure (AMF)
Remote Control (RSS)
Transportation kit
STANDARD
Magneto Thermal protection
Voltmeter
Lifting kit/Hook (except P4500)
Oil guard (on P6000S)
Overtemperature protection (on P6000s)
Oil pressure indicator (on P9000)
Automatic mains failure
Manual transfer switch
Transport kit
Complete panel with differential
THREE PHASE
(POWER LTP) kW/kVA
(POWER COP) kVA
SINGLE PHASE
(POWER LTP) kW/kVA
(POWER COP) kVA
POWER SPEC.
VOLTAGE Volt
FREQUENCY Hz
POWER FACTOR cosϕ
ENGINE
MODEL
TYPE
DISPLACEMENT cc
CYLINDER
POWER kW
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
CONSUMPTION
FUEL CONSUMPTION g/kWh
FUEL CONSUMPTION at 75% of load L/h
FUEL TANK CAPACITY L
RUNNING TIME at 75% of load h
NOISE EMISSION
GUARANTEED SOUND POWER LEVEL LWA dB(A)
NOISE PRESSURE LEVEL at 7 mt dB(A)
DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT (DRY)** Kg
SOCKET TYPE
ALTERNATOR AND SOCKET PROTECTION
ELECTRIC PROTECTION
SOCKET PROTECTION
**
COP
LTP
P4500
P6000
P6000
P6000s
P6000s
P9000
P9000
single phase
diesel
three phase
diesel
single phase
diesel
three phase
diesel
single phase
diesel
three phase
diesel
single phase
diesel
5,49/6,86
5,62
5,49/6,86
5,62
8,21/10,26
8,83
3,65/4,05
3,45
4,07/4,53
3,30
5,31/5,90
4,84
4,07/4,53
3,30
5,35/5,94
4,87
6,10/6,77
5,18
7,90/8,78
7,55
230
50
0,9
400/230
50
0,8/0,9
230
50
0,9
400/230
50
0,8/0,9
230
50
0,9
400/230
50
0,8/0,9
230
50
0,9
Yanmar
L70
296
1 Vertical
4,8
Natural
Air
Electric/Recoil
Yanmar
L100
406
1 Vertical
6,9
Natural
Air
Electric
Yanmar
L100
406
1 Vertical
6,9
Natural
Air
Electric
Yanmar
L100
406
1 Vertical
6,9
Natural
Air
Electric
Yanmar
L100
406
1 Vertical
6,9
Natural
Air
Electric
Ruggerini
MD150
654
2 In line
10
Natural
Air
Electric
Ruggerini
MD150
654
2 In line
10
Natural
Air
Electric
272
1,0
18
18,2
272
1,4
24
17,5
272
1,4
24
17,5
272
1,4
19
13,8
272
1,4
19
13,8
260
2,0
24
12,0
260
2,0
24
12,0
96
71
97
72
97
72
84
58
84
58
97
72
97
72
800
520
660
103
930
555
800
153
930
555
800
149
970
580
927
203
970
580
927
203
930
555
800
193
930
555
800
190
SCHUKO
230V 16A
230V 32A
SCHUKO
2 x 230V 16A
400V 16A
SCHUKO
230V 16A
230V 32A
SCHUKO
230V 16A
400V 16A
SCHUKO
230V 16A
230V 32A
SCHUKO
2 x 230V 16A
400V 16A
SCHUKO
230V 16A
230V 32A
IP23
IP 44
IP23
IP 44
IP23
IP 44
IP23
IP 44
IP23
IP 44
IP23
IP 44
IP23
IP 44
On electric version +3/8 Kg to add
Continuous Power
Maximum Power
65
PORTABLE GENSET & POWER EQUIPMENT
P SERIES
THE SILENT POWER II
Low noise level, AMF or RSS features and powerful, reliable diesel
engines. These generators are ideal for domestic backup power supply
or professional use in residential areas.
Equipment
OPTIONAL
Differential Protection (except P11000)
Insulation Monitoring (petrol versions only)
Preheater (diesel version only)
Automatic Mains Failure (AMF)
Remote Control (RSS)
Transportation kit
STANDARD
Magneto Thermal protection
Oil guard system (except P12000 diesel)
Oil Pressure Indicator (except P12000 petrol)
Insulation Monitoring (diesel version only)
Overtemperature Protection (P11000 only)
Voltmeter
Hourmeter (diesel version only)
Lifting kit/Hook
Transport kit
Automatic mains failure
Remote start stop
Isometer panel
THREE PHASE
(POWER LTP) kW/kVA
(POWER COP) kVA
SINGLE PHASE
(POWER LTP) kW/kVA
(POWER COP) kVA
POWER SPEC.
VOLTAGE Volt
FREQUENCY Hz
POWER FACTOR cosϕ
ENGINE
MODEL
TYPE
DISPLACEMENT cc
CYLINDER
POWER kW
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
CONSUMPTION
FUEL CONSUMPTION g/kWh
FUEL CONSUMPTION at 75% of load L/h
FUEL TANK CAPACITY L
RUNNING TIME at 75% of load h
NOISE EMISSION
GUARANTEED SOUND POWER LEVEL LWA dB(A)
NOISE PRESSURE LEVEL at 7 mt dB(A)
DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT (DRY) Kg
SOCKET TYPE
ALTERNATOR AND SOCKET PROTECTION
ELECTRIC PROTECTION
SOCKET PROTECTION
COP
LTP
P11000
P11000
P12000
P12000
P12000
three phase
diesel
single phase
diesel
three phase
diesel
three phase
petrol
single phase
petrol
12,63/15,79
11,00
11,14/13,92
11,83
8,48/10,60
10,00
5,25/6,56
6,00
9,54/10,60
10,00
9,38/10,42
6,45
8,27/9,19
6,94
10,69/11,88
10,00
400/230
50
0,8/0,9
230
50
0,9
400/230
50
0,8/0,9
400/230
50
0,8/0,9
230
50
0,9
Yanmar
3TNV70
854
3 In line
12
Natural
Water
Electric
Yanmar
3TNV70
854
3 In line
12
Natural
Water
Electric
Hatz
2 G 40
997
2 In line
15,4
Natural
Air
Electric
Honda
GX620
614
2-V
13,5
Natural
Air
Electric
Honda
GX620
614
2-V
13,5
Natural
Air
Electric
306
3,0
24
7,0
306
3,0
24
9,0
235
2,3
17
7,5
313
3,5
24
6,9
313
3,5
24
6,9
96
70
96
70
97
72
96
70
96
70
1451
650
975
325
1451
650
975
325
1270
830
920
275
930
555
800
176
930
555
800
166
230V 16A
230V 32A
400V 16A
2 x 230V 16A
230V 32A
230V 16A
230V 32A
400V 16A
SCHUKO
2 x 230V 16A
400V 16A
SCHUKO
230V 16A
230V 32A
IP23
IP 44
IP23
IP 44
IP23
IP 44
IP23
IP 44
IP23
IP 44
Continuous Power
Maximum Power
67
PORTABLE GENSET & POWER EQUIPMENT
W SERIES
MECHANIC WELDING
REGULATION
Welders from 170 to 220A with mechanical regulation of the welding
current. Reliability, sturdiness. Soundproof and open versions
depending on each particular need.
Equipment
OPTIONAL
Differential Protection (W180, W230 only)
Transportation kit
Small wheel transportation kit (WP180, WP230 only)
Welding kit
STANDARD
Magneto thermal protection
Oil guard system (petrol version only)
Voltmeter (WP180, WP230 only)
Double positive welding socket
(with additional resistance)
Serie W panel
Compactness
Serie WP panel
Lifting eye
WELDING GENERATOR
WELDING CURRENT A
MIN/MAX WELDING VOLTAGE V
WELDING SERVICE at 60% A
MAX DIAMETER OF ELECTRODE
RUTILE mm
BASIC mm
CELLULOSE mm
THREE PHASE
POWER (LTP) kW/kVA
POWER (COP) kVA
SINGLE PHASE
POWER (LTP) kW/kVA
POWER (COP) kVA
POWER SPEC.
VOLTAGE VOLT
FREQUENCY Hz
POWER FACTOR cosϕ
ENGINE
MODEL
TYPE
DISPLACEMENT cc
CYLINDER
POWER kW
ASPIRATION
COOLING SYSTEM
STARTING SYSTEM
CONSUMPTION
CONSUMPTION g/kWh
CONSUMPTION at 75% of load L/h
TANK CAPACITY L
RUNNING TIME at 75% of load h
NOISE EMISSION
NOISE LEVEL LWA dB(A)
ACOUSTIC PRESSURE at 7 m dB(A)
DIMENSIONS AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT (DRY)** Kg
SOCKET TYPE
ALTERNATOR AND SOCKET PROTECTION
ELECTRIC PROTECTION
SOCKET PROTECTION
**
•
COP
LTP
W170
W210
W180
W230
WP180
WP230
three phase
petrol
three phase
petrol
three phase
diesel
three phase
diesel
three phase
diesel
three phase
diesel
30-170
21,2/26,8
130
30-200
21,2/28
170
30-180
21,2/27,2
140
30-220
21,2/28,8
180
30-180
21,2/27,2
140
30-220
21,2/28,8
180
4
3,25
3,25
5
4
5
4
4
4
5
4
5
4
4
4
5
4
5
4,00/5,00
4,50
5,10/6,38
6,00
4,20/5,25
5,00
5,73/7,16
6,50
4,20/5,25
5,00
5,73/7,16
6,50
4,00/4,44
4,00
4,00/4,44
4,00
4,00/4,44
4,00
4,00/4,44
4,00
4,00/4,44
4,00
4,00/4,44
4,00
400/230
50
0,8/0,9
400/230
50
0,8/0,9
400/230
50
0,8/0,9
400/230
50
0,8/0,9
400/230
50
0,8/0,9
400/230
50
0,8/0,9
Honda
GX270
270
1 Vertical
6,3
Natural
Air
Recoil
Honda
GX390
389
1 Vertical
8,3
Natural
Air
Electric\Recoil
Yanmar
L100
406
1 Vertical
6,9
Natural
Air
Electric
Ruggerini
MD150
654
2 in line
10
Natural
Air
Electric
Yanmar
L100
406
1 Vertical
6,9
Natural
Air
Electric
Ruggerini
MD150
654
2 in line
10
Natural
Air
Electric
313
1,6
6
3,7
313
2,1
6,5
3
272
1,4
5,5
3,8
260
2,05
18
8,8
272
1,4
24
16,9
260
2,1
24
11,7
97
72
97
72
•
•
•
•
97
72
97
72
810
610
600
108
810
610
600
114
810
610
600
143
970
600
690
176
930
555
800
180
930
555
800
193
230V 16A
400V 16A
230V 16A
400V 16A
230V 16A
400V 16A
230V 16A
400V 16A
3 x 230V 16A
400V 16A
3 x 230V 16A
400V 16A
IP23
IP44
IP23
IP44
IP23
IP44
IP23
IP44
IP23
IP44
IP23
IP44
On electric version +3/8 Kg to add
For fixed installation only
Continuous Power
Maximum Power
69
PORTABLE GENSET & POWER EQUIPMENT
PW SERIES
DIRECT AND GEARBOX
TRANSMISSION
Easily transportable and ready to use; this is the ideal machine for
the myriad of professional and residential uses.
PW1500
PW150
PW3000
PW240
PW3000
petrol
petrol
petrol
petrol
diesel
200/2900
15
1450
240/3500
12,5
3400
200/2900
15
1450
Honda
GX340
337
1 Inclined
8
Natural
Air
Recoil
Honda
GX390
389
1 Inclined
9,6
Natural
Air
Electric/Recoil
Yanmar
L100
435
1 Vertical
7
Natural
Air
Electric
313
2
6,5
3,2
313
2,5
6,5
2,7
272
1,5
5,5
3,6
110
85
103
78
108
83
1040
590
790
72
951
765
655
64
1040
590
790
117
PUMP
MAX PRESSURE bar/psi
110/1600
150/2200
FLOW L/min
11,4
11,4
REVOLUTIONS rpm
1750
3400
ENGINE
MODEL
Honda
Honda
TYPE
GX160
GX160
DISPLACEMENT cc
163
163
CYLINDER
1 Inclined
1 Inclined
POWER kW
4
4
ASPIRATION
Natural
Natural
COOLING SYSTEM
Air
Air
STARTING SYSTEM
Recoil
Recoil
CONSUMPTION
CONSUMPTION g/kWh
313
313
CONSUMPTION at 75% of load L/h
1
1
TANK CAPACITY L
3,6
3,6
RUNNING TIME at 75% of load h
3,5
3,6
NOISE EMISSION
NOISE LEVEL LWA dB(A)
107
106
ACOUSTIC PRESSURE at 7 m dB(A)
82
81
DIMENSION AND WEIGHT
LENGTH mm
700
630
WIDTH mm
490
580
HEIGHT mm
890
540
WEIGHT (DRY)** Kg
44
32
STANDARD EQUIPMENT, OPTIONS AND ACCESSORIES (x: Standard, o: Optional)
2:1 GEAR BOX
x
DIRECT DRIVE
x
DOUBLE LANCE
LANCE
x
x
CHEMICAL INJECTION
x
x
PRESSURE HOSE
x
x
SUCTION HOSE WITH STRAINER
INLINE FILTER
x
x
OIL GUARD SYSTEM
x
x
TRANSPORTATION KIT
x
x
**
On electric version +3/8 Kg to add
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
ZG SERIES
ENERGY FOR AGRICULTURE
These generators provide an economic way to supply electricity to any part of your
agricultural land. Using the pto shaft of a tractor, the ZG class generator can produce
high quality power for any agricultural use.
ZG 100/3
ZG 150/3
THREE PHASE
(POWER COP) kW/kVA
6,40/8,00
7,68/9,60
SINGLE PHASE
(POWER COP) kW/kVA
2,40/2,67
2,88/3,20
POWER SPEC.
VOLTAGE Volt
400/230
400/230
FREQUENCY Hz
50
50
POWER FACTOR cosϕ
0,8/0,9
0,8/0,9
GEAR BOX REVOLUTION rpm
3000
3000
POWER (TRACTOR) HP\kW
14\10
17\12
REVOLUTION PTO SHAFT rpm
429
429
VOLTAGE SYSTEM REGULATOR
Compound
Compound
DIMENSIONS AND WEIGHT
LENGTH mm
813
813
WIDTH mm
788
788
HEIGHT mm
930
930
WEIGHT (DRY) Kg
90
125
STANDARD EQUIPMENT, OPTIONS AND ACCESSORIES (x: Standard, o: Optional)
MAGNETO THERMAL PROTECTION
x
x
DIFFERENTIAL PROTECTION
x
x
VOLTMETER
x
x
FREQUENCY METER
x
x
RELAY MIN-MAX
o
o
SOCKET TYPE
230V 16A
230V 16A
400V 16A
400V 16A
ALTERNATOR AND SOCKET
ELECTRIC PROTECTION
IP44
IP44
SOCKET PROTECTION
IP44
IP44
COP
LTP
ZG 200/3
ZG 300/3
ZG 300/15
ZG 400/15
ZG 500/15
10,88/13,60
16,00/20,00
16,80/21,00
20,80/26,00
25,60/32,00
4,08/4,53
6,00/6,67
6,30/7,00
7,80/8,67
9,60/10,67
400/230
50
0,8/0,9
3000
24\18
429
Compound
400/230
50
0,8/0,9
3000
35\25
429
Compound
400/230
50
0,8/0,9
1500
32\24
429
Electronic
400/230
50
0,8/0,9
1500
39\28
429
Electronic
400/230
50
0,8/0,9
1500
52\38
420
Electronic
813
788
930
135
813
788
930
175
1000
900
1000
210
1000
900
1000
275
1000
900
1000
315
x
x
x
x
o
230V 16A
400V 32A
x
x
x
x
o
230V 16A
400V 32A
x
x
x
x
o
230V 16A
400V 32A
x
x
x
x
o
230V 16A
400V 63A
x
x
x
x
o
230V 16A
CEE 400V 63A
IP44
IP44
IP44
IP44
IP44
IP44
IP44
IP44
IP44
IP44
Continuous Power
Maximum Power
71
PORTABLE GENSET & POWER EQUIPMENT
MP SERIES
FOR TRASH AND
CLEAN WATER
Whenever it is necessary to move large quantities
of water, whether during flooding, or simply filling
a pond, these petrol powered pumps can move it
quickly and efficiently.
MP36-2
MP56-3
MP34-2
MP66-3
petrol
petrol
petrol
petrol
Semitrash
26
930
3600
Trash
30
700
3600
Trash
27
1340
3600
Honda
GX160
163
1 Inclined
4,1
Natural
Air
Recoil
Honda
GX160
163
1 Inclined
4,0
Natural
Air
Recoil
Honda
GX240
242
1 Inclined
5,9
Natural
Air
Recoil
313
1,4
3,6
2,5
313
1
3,6
3,5
313
1,5
6
3,9
105
80
106
78
110
83
525
399
476
3
34
653
474
641
2
48
672
516
680
3
59
x
x
x
x
x
o
o
x
x
x
x
x
o
o
x
x
x
x
x
o
o
PUMP
TYPE
Semitrash
HEAD m
30
FLOW L/min
600
REVOLUTIONS rpm
3600
ENGINE
MODEL
Honda
TYPE
GX120
DISPLACEMENT cc
118
CYLINDER
1 Inclined
POWER kW
2,9
ASPIRATION
Natural
COOLING SYSTEM
Air
STARTING SYSTEM
Recoil
CONSUMPTION
CONSUMPTION g/kWh
313
CONSUMPTION at 75% of load L/h
1
TANK CAPACITY L
2,5
RUNNING TIME at 75% of load h
2,5
NOISE EMISSION
NOISE LEVEL LWA dB(A)
103
ACOUSTIC PRESSURE at 7 m dB(A)
78
DIMENSIONS AND WEIGHT
LENGTH mm
506
WIDTH mm
402
HEIGHT mm
421
INPUT/OUTPUT DIAMETER inch
2
WEIGHT (DRY) Kg
24
STANDARD EQUIPMENT, OPTION AND ACCESSORIES (x: Standard, o: Optional)
OIL GUARD SYSTEM
x
3 JUBILEE PIPE CLIPS
x
2 THREADED COUPLINGS
x
FILTER
x
SPARK PLUG TOOL
x
INLET PIPES 2”, 3” LENGTH 8/25 m
o
OUTLET PIPE 2”, 3” LENGTH 5/10/50/100 m
o
LIGHT GLOBE
ILLUMINATION NEEDS?
Light Globe can illuminate up to 10.500 m2 with a easy-to-use panel that
inflates and deflates the globe automatically.
GLOBE DIAMETER cm
LIT UP AREA m2
LUMEN
LAMP TYPE
WATT
VOLTAGE/FREQ. V/Hz
LAMP AUTONOMY HOURS
MAX HEIGHT m
ELEVATION TYPE
CONSUMPTION kW/h
OPERATING TEMPERATURE °C
POWER NEEDED TO RUN kW
WEIGHT Kg
PROTECTION GRID FOR THE LAMP
TRANSPORT CASE
TIMER
x
o
LIGHT GLOBE
80/250
LIGHT GLOBE
100/400
LIGHT GLOBE
140/1000
LIGHT GLOBE
140/2000
80
up to 2.800
25.500
Metal iodide
250
230/50
6.000
2,8
winch
0,4
-20/+40°C
0,85
41
o
o
100
up to 4.100
42.500
Metal iodide
400
230/50
6.000
2,8
winch
0,6
-20/+40°C
1,5
41
o
o
140
up to 6.100
80.000
Metal iodide
1000
230/50
6.000
6,0
winch
1,7
-20/+40°C
3,0
74
o
o
x
140
up to 10.500
189.000
Metal iodide
2000
230/50
6.000
6,0
winch
3,0
-20/+40°C
6,0
74
o
o
x
standard
optional
Case light globe
Protection grid
Winch
Electrical panel
73
PORTABLE GENSET & POWER EQUIPMENT
LIGHT TOWER
LIGHTING POWER
Transportable lighting tower kit, to be installed
on GBL or GSL soundproof Pramac range,
developed for rental use,
public activities and other events.
9 m hydraulic mast with easy erection and
turning with redundant safety devices.
The 6 floodlights are connected to the
generator with only a three phase socket.
It's also available as a small portable model
used with 5 - 7 kVA generators.
LUMEN
LAMP TYPE
WATT
VOLTAGE/FREQ. V/Hz
LAMP PROTECTION
MAX HEIGHT m
ELEVATION TYPE
CONSUMPTION kVA/h
OPERATING TEMPERATURE °C
WEIGHT Kg
TURNING ANGLE
LIGHT TOWER 500Wx4
LIGHT TOWER 1500Wx6
LIGHT TOWER 400Wx6
single phase
three phase
three phase
38.000
Halogen
500x4
230/50
IP55
4,6
Winch
2,0
-15/+40
34
-
200.000
Quartz-Iode
1500x6
400/50
IP55
9
Hydraulic
12
-15/+40
882
355
192.000
Metal Halide
400x6
400/50
IP55
9
Hydraulic
4
-15/+40
882
355
HE SERIES
THE EASY LIFT
The best way to lift a big weight up to 500Kg.
A lot of accessories available to allow
an easy installation of the hoist.
ENGINE
ENGINE POWER kW
VOLTAGE V
FREQUENCY Hz
ELEVATION
MAX LOAD Kg
ELEVATION SPEED m/min
MAX ELEVATION m
CABLE DIAMETER mm
DIMENSION AND WEIGHT
LENGTH mm
WIDTH mm
HEIGHT mm
WEIGHT Kg
OPTIONS
REMOTE CONTROL (RSS)
SLIDING TRUCK
WEIGHT SUPPORT FOR HOIST
WINDOW STRUT
INDOOR PROP
OUTDOOR PROP
SCAFFOLD SUPPORT
APS SUPPORT**
**
o
HE200
HE240
HE300
HE300
HE500
HE500
single phase
single phase
single phase
three phase
single phase
three phase
0,75
230
50
0,75
230
50
1,10
230
50
1,50
400
50
1,10
230
50
1,85
400
50
200
25
25
5
200
25
25
5
300
25
25
6
300
25
25
6
500
12
25
5
500
27
25
8
690
210
350
37
690
210
350
40
860
320
530
48
860
320
530
50
860
320
530
48
860
320
550
50
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
under request, to be installed in production only
optional
75
ELECTRICAL EQUIPMENT - AMF
GSA12L / GBW (15-45p/y) / GBL (30d-42d)
CUBICLE
Digital instrumentation
Engine protection unit
Voltmeter
Mains voltage
Ammeter
Frequency meter
Hourmeter
Battery voltage and intensity
ALARMS & SHUTDOWNS
Generator voltage out of limits*
Over-load*
Battery charger alternator failure*
Battery voltage out of limits
Frequency out of limits*
Low oil pressure*
High temperature* (not GSA12L)
Fail to start
External shutdown
PROTECTION DEVICES
Emergency stop button
OTHER FEATURES
Acustic alarm
Phases detector
Battery charger
Terminals for genset cubicle connexion
Change over contactors
with mechanical interlock
5 meters control cables
External start capability
GSA (22d, 30d, 42d, 65d) / GSL (30d, 42d) / GBW (65p, 80p, 110p) / GSW (15P, 22P) / GSW (15d, 22d)
CUBICLE
Digital instrumentation
Engine protection unit
3 Voltmeter
Mains voltage
3 Ammeter
Frequency meter
Hourmeter
Battery voltage and intensity
Speed
Power (kVA, kW, kVAr, cosϕ)
Fuel level gauge
Engine temperature indicator
(not GSA42d/65d)
ALARMS & SHUTDOWNS
Generator voltage out of limits*
Over-load*
Battery charger alternator failure*
Battery voltage out of limits
Frequency out of limits*
Low fuel level*
Low oil pressure*
High temperature*
Low coolant level* (only GBW65d-80d)
Fail to start
External shutdown
PROTECTION DEVICES
Emergency stop button
OTHER FEATURES
Acustic alarm
Phases detector
Battery charger
Terminals for genset cubicle connexion
Change over contactors
with mechanical interlock
5 meters control cables
External start capability
GSW (65d, 80d, 110d, 145d, 170d, 195d, 220d) / GSW (530d, 560d) / GSW (275V, 330V, 415V, 450V, 510V, 560V, 590V)
CUBICLE
Digital instrumentation
Engine protection unit
3 Voltmeter
Mains voltage
3 Ammeter
Frequency meter
Hourmeter
Battery voltage and intensity
Speed
Power (kVA, kW, kVAr, cosϕ)
Fuel level gauge
Oil pressure indicator (on GSW195d)
Engine temperature indicator
*
ALARMS & SHUTDOWNS
Generator voltage out of limits*
Over-load*
Battery charger alternator failure*
Battery voltage out of limits
Frequency out of limits*
Low fuel level*
Low oil pressure*
High temperature*
Low Coolant level* (on GSW195d)
Fail to start
External shutdown
PROTECTION DEVICES
Emergency stop button
OTHER FEATURES
Acustic alarm
Phases detector
Battery charger
Terminals for genset cubicle connexion
Change over contactors
with mechanical interlock
5 meters control cables
CANBUS communication (on GSW275d)
External start capability
With shutdown protection
77
ELECTRICAL EQUIPMENT - PANELS
1.
MCP Analogue
CUBICLE
Analogue instrumentation
Voltmeter
Hourmeter
ALARMS & SHUTDOWNS
Battery charger alternator failure*
Low oil pressure*
PROTECTION DEVICES
III poles Circuit Breaker
SOCKETS
Single phase CEE socket
Three phase CEE socket
MANUAL ANALOGUE
GBA12L / GBA6d -14d -17d Open set
2.
MCP Digital
MANUAL DIGITAL
GSA22d - 30d - 42d - 65d Open set
GLS30d - 42d Open set
GSW65d - 80d - 110d - 145d - 170d
195d - 220d Open set
CUBICLE
Digital instrumentation
Engine protection unit
3 Voltmeter
3 Ammeter
Frequency meter
Hourmeter
Battery voltage
Speed
Power (kVA)
Fuel level gauge
Engine temperature indicator
(not GSA42d/65d)
ALARMS & SHUTDOWNS
Generator voltage out of limits*
Over-load*
Battery voltage out of limits
Frequency out of limits*
Low fuel level*
Low oil pressure*
High temperature*
Fail to start
External shutdown
PROTECTION DEVICES
(III poles on GSA65d)
Differential protection
Emergency stop button
OTHER FEATURES
External start capability (optional)
3.
MCP Analogue
CUBICLE
Analogue instrumentation
Engine protection unit
3 Voltmeter
3 Ammeter
Frequency meter
Hourmeter
Fuel level gauge
Oil pressure indicator
Engine temperature indicator
ALARMS & SHUTDOWNS
Battery charger alternator failure*
Low fuel level*
Low oil pressure*
High temperature*
PROTECTION DEVICES
(III poles on GSA65d)
Differential protection
Emergency stop button
OTHER FEATURES
External start capability (optional)
MANUAL
GSA22d - 30d - 42d - 65d Open set
GLS30d - 42d Open set
GSW65d - 80d - 110d - 145d
170d - 195d - 220d
4.
ACP
AUTOMATIC
GSA22d - 30d - 42d - 65d Open set
GSL30d - 42d Open set
GSW65d - 80d - 110d - 145d
170d - 195d - 220d Open set
*
With shutdown protection
CUBICLE
Digital instrumentation
Engine protection unit
3 Voltmeter
Mains voltage
3 Ammeter
Frequency meter
Hourmeter
Battery voltage and intensity
Speed
Power (kVA, kW, kVAr, cosϕ)
Fuel level gauge
Engine temperature indicator
(not GSA42d/65d)
ALARMS & SHUTDOWNS
Generator voltage out of limits*
Over-load*
Battery charger alternator failure*
Battery voltage out of limits
Frequency out of limits*
Low fuel level*
Low oil pressure*
High temperature*
Fail to start
External shutdown
PROTECTION DEVICES
(III poles on GSA65d)
Differential protection
Emergency stop button
OTHER FEATURES
Acustic alarm
Phases detector
Battery charger
Terminals for an external panel connexion
(LTS/AMF/ATS)
Low potential signallization relay card
(optional)
External start capability
5.
MCP
CUBICLE
Analogue instrumentation
Engine protection unit
Voltmeter
Ammeter
Hourmeter
ALARMS & SHUTDOWNS
Battery charger alternator failure*
Low oil pressure*
High temperature*
External shutdown
PROTECTION DEVICES
III poles Circuit Breaker
Differential protection
Emergency stop button
SOCKETS
Schuko socket
2 x Single phase CEE socket
2 x Three phase CEE socket
MANUAL
GBW15 - 45p /y
Open set and soundproof
GBL30d - 42d Soundproof
6.
ACP
CUBICLE
Digital instrumentation
Engine protection unit
Voltmeter
Mains voltage
Ammeter
Frequency meter
Hourmeter
Battery voltage and intensity
ALARMS & SHUTDOWNS
Generator voltage out of limits*
Over-load*
Battery charger alternator failure*
Battery voltage out of limits
Frequency out of limits*
Low oil pressure*
High temperature*
Fail to start
External shutdown
AUTOMATIC
GBL30d - 42d Soundproof
GBW15 - 45p /y
Open set and Soundproof
PROTECTION DEVICES
III poles Circuit Breaker
Differential protection
Emergency stop button
SOCKETS
Three phase CEE socket
OTHER FEATURES
Acustic alarm
Phases detector
Battery charger
Terminals for an external panel connexion
(LTS/AMF/ATS)
External start capability
7.
MCP Analogue
MANUAL ANALOGUE
CUBICLE
MCP (ana)
Analogue instrumentation
Engine protection unit
3 Voltmeter
3 Ammeter
Frequency meter
Hourmeter
Fuel level gauge
Oil pressure indicator
Engine temperature indicator
ALARMS & SHUTDOWNS
Battery charger alternator failure*
Low fuel level*
Low oil pressure*
High temperature*
PROTECTION DEVICES
IV poles
Differential protection
Emergency stop button
OTHER FEATURES
External terminal board for load connection
External start capability (optional)
GSL30d - 42d Soundproof
GSW15p - 22p Soundproof
GSW15d - 22d Soundproof
(optional for GSW65d - 80d - 110d
145d - 170d - 190d - 220d Soundproof)
8.
ACP
MANUAL / AUTOMATIC
GSW530d - 560d
Open set and Soundproof
GSW275V - 330V - 415V
450V - 510V - 560V -590V
Open set and Soundproof
*
CUBICLE
Digital instrumentation
Engine protection unit
3 Voltmeter
Mains voltage
3 Ammeter
Frequency meter
Hourmeter
Battery voltage and intensity
Speed
Power (kVA, kW, kVAr, cosϕ)
Fuel level gauge
Oil pressure indicator
Engine temperature indicator
ALARMS & SHUTDOWNS
Generator voltage out of limits*
Over-load*
Battery charger alternator failure*
Battery voltage out of limits
Frequency out of limits*
Low fuel level*
Low oil pressure*
High temperature*
Low coolant level*
Fail to start
External shutdown
PROTECTION DEVICES
III poles Circuit Breaker (opt IV poles)
Differential protection
Emergency stop button
OTHER FEATURES
Acustic alarm
Phases detector
Battery charger
External terminal board for load connection
Terminals for an external panel connexion
(LTS/AMF/ATS)
CANBUS communication
External start capability (optional)
With shutdown protection
79
9.
ACP
AUTOMATIC
GSW15d - 22d Soundproof
GSW15P - 22P Soundproof
GSL30d - 42d Soundproof
GSW65d - 80d - 110d - 145d - 170d
195d - 220d Soundproof
CUBICLE
Digital instrumentation
Engine protection unit
3 Voltmeter
Mains voltage
3 Ammeter
Frequency meter
Hourmeter
Battery voltage and intensity
Speed
Power (kVA, kW, kVAr, cosϕ)
Fuel level gauge
Engine temperature indicator
ALARMS & SHUTDOWNS
Generator voltage out of limits*
Over-load*
Battery charger alternator failure*
Battery voltage out of limits
Frequency out of limits*
Low fuel level*
Low oil pressure*
High temperature*
Fail to start
External shutdown
PROTECTION DEVICES
IV poles
Differential protection
Emergency stop button
OTHER FEATURES
Acustic alarm
Phases detector
Battery charger
External terminal board for load connection
Terminals for an external panel connexion
(LTS/AMF/ATS)
Low potential signallization relay card (optional)
External start capability (optional)
10.
MCP Analogue
CUBICLE
MCP (ana)
Analogue instrumentation
Engine protection unit
Voltmeter
Ammeter
Frequency meter
Hourmeter
ALARMS & SHUTDOWNS
Battery charger alternator failure*
Low fuel level*
Low oil pressure*
High temperature*
External shutdown
PROTECTION DEVICES
IV poles Circuit Breaker
Differential protection
Emergency stop button
SOCKETS
Single phase CEE socket
Three phase CEE socket
OTHER FEATURES
External terminal board for load connection
MANUAL
GBW65p - 80p - 110p
Open set and Soundproof
11.
ACP
AUTOMATIC
GBW 65p - 80p - 110p
Open set and Soundproof
CUBICLE
Digital instrumentation
Engine protection unit
3 Voltmeter
Mains voltage
3 Ammeter
Frequency meter
Hourmeter
Battery voltage and intensity
Speed
Power (kVA, kW, kVAr, cosϕ)
Fuel level gauge
Engine temperature indicator
ALARMS & SHUTDOWNS
Generator voltage out of limits*
Over-load*
Battery charger alternator failure*
Battery voltage out of limits
Frequency out of limits*
Low fuel level*
Low oil pressure*
High temperature*
Fail to start
External shutdown
PROTECTION DEVICES
IV poles Circuit Breaker
Differential protection
Emergency stop button
OTHER FEATURES
Acustic alarm
Phases detector
Battery charger
External terminal board for load connection
Terminals for an external panel connexion
(LTS/AMF/ATS)
External start capability (optional)
12.
MCP Digital
MANUAL
GSW65d - 80d - 110d - 145d - 170d
195d - 220d Soundproof
*
With shutdown protection
CUBICLE
Digital instrumentation
Engine protection unit
3 Voltmeter
3 Ammeter
Frequency meter
Hourmeter
Battery voltage
Speed
Power (kVA)
Fuel level gauge
Oil pressure indicator (standard on
GSW195d/220d/275d)
Engine temperature indicator
ALARMS & SHUTDOWNS
Generator voltage out of limits*
Over-load*
Battery voltage out of limits
Frequency out of limits*
Low fuel level*
Low oil pressure*
High temperature*
Low Coolant level*
(not available on GSW110d/145d/170d)
Fail to start
External shutdown
PROTECTION DEVICES
III poles Circuit Breaker (opt IV poles)
Differential protection
Emergency stop button
OTHER FEATURES
External terminal board for load connection
External start capability (optional)
13.
MCP Digital
MANUAL
GSL30d - 42d Soundproof
GSW15P - 22P Soundproof
GSW15d - 22d Soundproof
CUBICLE
Digital instrumentation
Engine protection unit
3 Voltmeter
3 Ammeter
Frequency meter
Hourmeter
Battery voltage
Speed
Power (kVA)
Fuel level gauge
Engine temperature indicator (only for GSL)
ALARMS & SHUTDOWNS
Generator voltage out of limits*
Over-load*
Battery voltage out of limits
Frequency out of limits*
Low fuel level*
Low oil pressure*
High temperature*
Fail to start
External shutdown
PROTECTION DEVICES
IV poles
Differential protection
Emergency stop button
OTHER FEATURES
External terminal board for load connection
External start capability (optional)
14.
MCP Extended
CUBICLE
Analogue instrumentation
Engine protection unit
3 Voltmeter
3 Ammeter
Frequency meter
Hourmeter
Fuel level gauge
MANUAL
ALARMS & SHUTDOWNS
Battery charger alternator failure*
Low fuel level*
Low oil pressure*
High temperature*
External shutdown
PROTECTION DEVICES
IV poles Circuit Breaker
Differential protection
Emergency stop button
SOCKETS
Single phase CEE socket
Three phase CEE socket
OTHER FEATURES
External terminal board for load connection
GBW65p - 80p - 110p
Open set and Soundproof
*
With shutdown protection
81
+++
[ Energy
mover]
EUROPE
NORTH AMERICA
AFRIQUE
PRAMAC FRANCE S.A.S.
St. Nizier sous Charlieu, Lyon - France
[email protected]
Tel.: +33 (0) 477 692 020
Fax: +33 (0) 477 601 778
PRAMAC INDUSTRIES Inc.
Regional Head Office and USA Sales Office
Marietta, Georgia - USA
[email protected]
Tel: +1 770 218 5430
Fax: +1 770 218 2810
PRAMAC LIFTER AFRIQUE Tr. S.a.r.l.
Dakar Yoff - Senegal
[email protected]
Tel.: +221 33 849 6232
Fax: +221 33 822 5800
International Sales Office
Medley, Florida - USA
[email protected]
Tel: +1 305 888 9911
Fax: +1 305 888 3711
ASIA
PRAMAC LIFTER GmbH
Fellbach, Stuttgart - Germany
[email protected]
Tel.: +49 711 517 4290
Fax: +49 711 517 42999
PRAMAC Sp z.o.o.
Wroclaw – Poland
[email protected]
Tel.: +48 71 3321700
Fax: +48 71 3321709
SOUTH AMERICA
& CARIBBEAN
PRAMAC BRASIL EQUIPAMENTOS LTDA.
Sorocaba, SP - BRASIL
[email protected]
Tel: +55 15 3225 4415
Fax:+55 15 3225 3852
PRAMAC UK Ltd.
Dukestown, Tredegar - United Kingdom
[email protected]
Tel.: +44 1495 713 300
Fax: +44 1495 718 766
PRAMAC CARIBE C. por A.
Los Restauradores, Santo Domingo
Dominican Republic
[email protected]
Tel.: +1 809 531 0067
Fax: +1 809 531 0273
S.C. PRAMAC Group SRL
Bucarest - Romania
[email protected]
Tel.: +40 213001340
Fax: +40 213001340
PRAMAC de Puerto Rico Inc.
Barrio Hato Tejas, Bayamón - Puerto Rico
[email protected]
Tel.: +1 787 273 3178
Fax: +1 787 273 3179
PRAMAC S.p.A.
Headquarters
Casole d’Elsa, Siena - Italy
[email protected]
Tel.: +39 0577 9651 Fax: +39 0577 949076
WWW.PRAMAC.COM
PRAMAC (ASIA) PTE LTD.
Singapore
[email protected]
Tel.: +65 6558 7888
Fax: +65 6558 7878
PRAMAC (CHINA) LIMITED
Hong Kong Regional Head Office
Kowloon Bay - Hong Kong
[email protected]
Tel.: +852 211 638 89
Fax: +852 211 998 22
PRAMAC SIENA (SHANGHAI) TRADING CO. LTD.
Shanghai - China
[email protected]
Tel.: +86 21 5239 1666
Fax: +86 21 5239 3868
The producer reserves the right to introduce changes to models and features without prior notice | Ed.Ⅰ/2007
PRAMAC IBERICA S.A.
Balsicas, Murcia - Spain
[email protected]
Tel.: +34 968 334 900
Fax: +34 968 579 321