Slique T2
Transcription
Slique T2
A10.0 Project Slique T2 3/4˝ Undercabinet/Display Light T2 Fluorescent Project Location SQ Catalog # Type Description Slique T2 is the sleekest fluorescent undercabinet and display luminaire avail-able. Slique T2 utilizes a T2 fluorescent lamp and an integral miniature ballast. This allows a 3/4” x 1-3/4” luminaire cross-section and eliminates the need to remote-mount a ballast. The available plug-in modules, interconnect cords and connectors simplify the installation and support different layout configurations. Slique T2 is backed by Alkco’s lifetime guarantee. Additional features: • Specular aluminum reflector improves luminaire efficiency • Slique T2 is available in 4 product lengths • The acrylic lens is guaranteed not to discolor for the life of the product • Optional glass shelf fascia extrusion simplifies mounting to glass shelves • Slique T2 is available in three standard colors • Backed by a Lifetime Warranty Specifications Construction - Extruded aluminum housing with injection molded polycarbonate endcaps and covers. 80, and an average rated life of 10,000 hours. 4100K lamps can be specified as an option. Reflector & Lens - Specular aluminum, asymmetric reflector. Extruded acrylic lens with DR additive and linear prisms. Listings - UL and CUL Listed. The luminaire is also IBEW labeled. Finish - Slique T2 is available in either a white or black polyester powder-coat paint finish. The endcaps and covers are molded to match. Slique T2 can also be specified in an acid-etched, satin aluminum finish with molded endcaps and covers to match. Lamps - Either one or two, FM11 or FM13 T2 fluorescent lamps (with axial base) are provided with each luminaire. The supplied miniature T2 lamps have a 3000K color temperature, CRI of Electrical - Slique T2 has a proprietary, integral electronic ballast for 120 volt applications. 277 volt, 347 volt and dimming applications are not supported. Installation - A system consists of one Power Feed (either Direct Power Feed or Portable Power Feed) for each group of interconnected luminaires. The electrical power supply is brought to a Power Feed. The Direct Power Feed accepts a 3/8” flexible metal conduit/non-metallic sheathed wiring connector and is available in either a right- or left-end version. The alternative is to use the Portable Power Feed in either a right- or left-end version. The Power Feeds can plug into the end of the Slique T2 housing or mounted remotely and connected with one of the interconnect cords. The In-line Connector continues power through multiple luminaires mounted endto-end. Interconnect Cords can be used to connect luminaires spaced some distance apart and to navigate around corners or bypass obstructions. The maximum number of luminaires to be interconnected cannot exceed 6.0 amps, with a maximum distance between luminaires not exceeding 3 feet. Warranty - All components, except lamps, are warranted to perform for the life of the original installation. Ordering Information Sample Catalog No: SQ111 - 120 - AL - SQC Each individual or string of interconnected Slique T2 luminaires require a Power Feed. Select below. 120 NOM. LENGTH Model Number 18-15/16” SQ111 (1) FM11 T2 Fluorescent Voltage 120 22-15/16” SQ113 (1) FM13 T2 Fluorescent 36-15/16” SQ211 (2) FM11 T2 Fluorescent Finish (standard color is WHG) WHG White Glossy BLKG Black Glossy AL Aluminum 44-15/16” SQ213 (2) FM13 T2 Fluorescent Sample Catalog No: SQ-DWR - 120 - AL 120 NOM. LENGTH Power Feed Style 4-7/8” SQ-DWR Direct wire power feed, right end 4-7/8” SQ-DWL Direct wire power feed, left end 3-1/2” SQ-CSR Portable power feed, right end (with 6ft. cordset) 3-1/2” SQ-CSL Portable power feed, left end (with 6ft. cordset) 11500 Melrose Avenue Franklin Park, Illinois 60131 Phone: 847-451-0700 Toll-Free: 1-866-50ALKCO Fax: 847-451-7512 www.alkco.com 06/10 ©2010 Alkco Lighting. All rights reserved. Product designs protected by copyright. We reserve the right to change details of design, materials and finishes. Voltage 120 Options FC1 In-line connector for end-to-end connections CCW1 White 12-36” coiled interconnect cord CCB1 Black 12-36” coiled interconnect cord SCW1 White 6” straight interconnect cord SCB1 Black 6” straight interconnect cord 41K 4100K lamp substituted for 3000K lamp SQGSF-4 4’ Fascia extrusion for mounting to 3/8” or 1/2” glass shelf SQGSF-8 8’ Fascia extrusion for mounting to 3/8” or 1/2” glass shelf 1 Finish (standard color is WHG) WHG White Glossy BLKG Black Glossy AL Aluminum Order one connector or interconnect cord for each connection point. A10.0 Project Slique T2 Type 3/4˝ Undercabinet/Display Light T2 Fluorescent SQ Dimensional Data 1-7/8” (47.6mm) Left End Power Feed 17/32” 1-3/4” (13.5mm) (44.5mm) 1-3/4” Left End* Right End* Lens (44.5mm) 3/4” (19.1mm) Cross Section 4-1/4” (108.0mm) Optional Glass Shelf Fascia 4-1/2” (114.3mm) (3/8” - 1/2” shelf thickness) SQ111 18-15/16” SQ113 22-15/16” SQ211 36-15/16” * Left End Power Feed illustrated in drawing above. Left or Right End Power Feed Available. Specify only one Power Feed for each fixture (or run of fixtures). Alternate Remote Mounting of Power Feed with Interconnect Cord Lens (465.1mm) (566.7mm) (922.3mm) 44-15/16” SQ213 (1227.1mm) 1-5/32” 1-3/4” 3/4” (44.5mm) (29.4mm) (19.1mm) 4-1/4” 4-1/4” Power Feed (End View) (108.0mm) (108.0mm) 5” 4-1/2” (127.0mm) (114.3mm) Portable Power Feed Direct Power Feed Photometric Data SQ113 SQ213 (1) 13W T2 Fluorescent 860 lumens per lamp (2) 13W T2 Fluorescent 860 lumens per lamp Report No.: ITL51988 Efficiency: 66.9% Report No.: ITL51989 Efficiency: 68.1% 90˚ 90˚ 75˚ 75˚ 150 80 60˚ 60˚ 300 160 45˚ 45˚ 450 240 0˚ 15˚ 30˚ LEGEND: 0-deg: 90-deg: 180-deg: 0˚ LEGEND: 0-deg: 90-deg: 180-deg: 15˚ 30˚ ELECTRICAL DATA Lamp Wattage 11W Input Watts 14 Max. Amps .11 Power Factor >.95 THD <15% 13W 16 .13 >.95 <15% 277V, 347V and dimming ballasts not available (2) 11W (2)13W 28 32 .23 .27 >.95 >.95 <15% <15% Hg Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small amounts of mercury. Such lamps are labeled “Contains Mercury” and/or with the symbol “Hg”. Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycling and disposal can be found at www.lamprecycle.org 11500 Melrose Avenue Franklin Park, Illinois 60131 Phone: 847-451-0700 Toll-Free: 1-866-50ALKCO Fax: 847-451-7512 www.alkco.com 06/10 ©2010 Alkco Lighting. All rights reserved. Product designs protected by copyright. We reserve the right to change details of design, materials and finishes. A10.0 Project Slique T2 Type 3/4˝ Undercabinet/Display Light T2 Fluorescent SQ Photometric Data SQ113 CO-EFFICIENTS OF UTILIZATION (1) 13W T2 Fluorescent 860 lumens per lamp rc rw Report No.: ITL51988 Efficiency: 66.9% 90˚ 75˚ 80 60˚ 160 45˚ 240 0˚ 15˚ 30˚ LEGEND: 0-deg: 90-deg: 180-deg: RCR 0 1 2 3 4 5 6 7 8 9 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 78 70 63 57 52 48 44 41 38 35 33 76 68 61 55 50 46 42 39 36 34 32 72 61 52 45 40 36 32 29 26 24 22 68 57 49 43 38 34 30 27 25 23 21 68 55 46 39 34 29 26 23 21 19 17 64 54 46 41 36 32 29 26 24 22 20 64 51 41 34 29 25 22 19 17 15 14 62 49 40 33 27 23 20 18 15 14 12 ZONAL LUMEN SUMMARY 78 66 57 50 44 39 35 31 28 26 24 78 63 52 44 37 32 28 25 22 20 18 78 60 48 39 32 28 24 21 18 16 15 Horizontal Angle 0° 120 135 182 221 239 232 203 157 127 104 88 74 43 45° 120 130 156 183 198 192 168 130 94 65 53 42 22 90° 120 120 116 108 98 83 63 39 14 2 0 0 0 135° 120 114 108 102 91 67 41 19 7 1 0 0 0 180° 120 113 109 105 87 54 26 11 5 1 0 0 0 (2) 13W T2 Fluorescent 860 lumens per lamp rc rw 75˚ 150 60˚ 300 45˚ 450 0˚ 15˚ 30˚ LEGEND: 0-deg: 90-deg: 180-deg: 11500 Melrose Avenue Franklin Park, Illinois 60131 Phone: 847-451-0700 Toll-Free: 1-866-50ALKCO Fax: 847-451-7512 www.alkco.com 06/10 ©2010 Alkco Lighting. All rights reserved. Product designs protected by copyright. We reserve the right to change details of design, materials and finishes. RCR 0 1 2 3 4 5 6 7 8 9 10 I 72 58 48 41 35 30 27 24 21 19 17 72 56 45 37 31 26 23 20 18 16 14 68 53 43 36 30 26 22 19 17 15 14 64 52 44 37 32 28 25 22 20 18 16 Lumens % Lamp % Fixt. 0-30 113 13.1 19.6 0-40 199 23.1 34.6 0-60 382 44.4 66.3 0-90 534 62.1 92.8 90-120 38 4.4 6.5 90-130 40 4.7 7.0 90-150 41 4.8 7.2 90-180 41 4.8 7.2 0-180 575 66.9 100.0 Effective floor cavity reflectance=20% 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 80 72 65 59 53 49 45 42 39 36 34 78 69 62 56 51 47 43 40 37 35 33 73 62 54 47 41 37 33 30 27 25 23 69 59 51 44 39 35 31 28 26 24 22 69 57 47 40 35 30 27 24 21 19 18 65 55 48 42 37 33 30 27 25 23 21 64 50 41 34 29 24 21 18 16 14 13 ZONAL LUMEN SUMMARY 80 68 58 51 45 40 36 32 29 27 24 80 64 53 45 38 33 29 26 23 21 19 80 61 49 40 34 29 25 22 19 17 15 78 66 57 49 44 39 35 31 28 26 24 Horizontal Angle 0° 260 294 385 459 487 455 386 310 245 196 165 133 72 76 58 47 38 32 27 23 20 18 16 14 80 70 50 30 10 CANDLEPOWER DISTRIBUTION Vertical Angle 0° 5° 15° 25° 35° 45° 55° 65° 75° 85° 90° 95° 105° 76 61 51 43 36 32 28 25 22 20 18 Zone CO-EFFICIENTS OF UTILIZATION 90˚ 76 64 55 48 42 38 34 30 28 25 23 CANDLEPOWER DISTRIBUTION Vertical Angle 0° 5° 15° 25° 35° 45° 55° 65° 75° 85° 90° 95° 105° Effective floor cavity reflectance=20% 70 70 50 30 10 SQ213 Report No.: ITL51989 Efficiency: 68.1% I 80 70 50 30 10 45° 260 284 337 387 409 394 330 255 187 127 102 80 40 90° 260 261 252 237 214 182 138 82 31 4 0 0 0 135° 260 246 229 215 188 140 84 42 17 3 0 0 0 78 63 52 44 38 33 29 25 23 21 19 78 60 48 39 33 28 24 21 19 17 15 Zone 180° 260 241 228 216 178 116 57 24 10 3 0 0 0 73 60 50 42 36 31 28 25 22 20 18 73 57 46 38 32 27 24 21 18 16 15 Lumens % Lamp % Fixt. 0-30 241 14.0 20.5 0-40 420 24.4 35.9 0-60 791 46.0 67.6 0-90 1093 63.6 93.4 90-120 69 4.0 5.9 90-130 74 4.3 6.3 90-150 77 4.5 6.6 90-180 77 4.5 6.6 0-180 1171 68.1 100.0 69 55 44 37 31 27 23 20 18 16 15 65 54 45 39 33 29 26 23 21 19 17 65 52 43 36 30 26 23 20 18 16 14