A10.0
Project
Slique T2
3/4˝ Undercabinet/Display Light
T2 Fluorescent
Project Location
SQ
Catalog #
Type
Description
Slique T2 is the sleekest fluorescent undercabinet and display luminaire
avail-able. Slique T2 utilizes a T2 fluorescent lamp and an integral miniature
ballast. This allows a 3/4” x 1-3/4” luminaire cross-section and eliminates the
need to remote-mount a ballast. The available plug-in modules, interconnect
cords and connectors simplify the installation and support different layout
configurations. Slique T2 is backed by Alkco’s lifetime guarantee.
Additional features:
• Specular aluminum reflector improves luminaire efficiency • Slique T2 is available in 4 product lengths
• The acrylic lens is guaranteed not to discolor for the life of the product
• Optional glass shelf fascia extrusion simplifies mounting to glass shelves
• Slique T2 is available in three standard colors
• Backed by a Lifetime Warranty
Specifications
Construction - Extruded aluminum housing with
injection molded polycarbonate endcaps and covers.
80, and an average rated life of 10,000 hours.
4100K lamps can be specified as an option.
Reflector & Lens - Specular aluminum, asymmetric
reflector. Extruded acrylic lens with DR additive and
linear prisms.
Listings - UL and CUL Listed. The luminaire is also
IBEW labeled.
Finish - Slique T2 is available in either a white
or black polyester powder-coat paint finish.
The endcaps and covers are molded to match.
Slique T2 can also be specified in an acid-etched,
satin aluminum finish with molded endcaps and
covers to match.
Lamps - Either one or two, FM11 or FM13 T2
fluorescent lamps (with axial base) are provided
with each luminaire. The supplied miniature T2
lamps have a 3000K color temperature, CRI of
Electrical - Slique T2 has a proprietary, integral
electronic ballast for 120 volt applications. 277 volt,
347 volt and dimming applications are not
supported.
Installation - A system consists of one Power Feed
(either Direct Power Feed or Portable Power Feed)
for each group of interconnected luminaires. The
electrical power supply is brought to a Power Feed.
The Direct Power Feed accepts a 3/8” flexible metal
conduit/non-metallic sheathed wiring connector
and is available in either a right- or left-end version.
The alternative is to use the Portable Power Feed in
either a right- or left-end version. The Power Feeds
can plug into the end of the Slique T2 housing or
mounted remotely and connected with one of the
interconnect cords. The In-line Connector continues
power through multiple luminaires mounted endto-end. Interconnect Cords can be used to connect
luminaires spaced some distance apart and to
navigate around corners or bypass obstructions. The
maximum number of luminaires to be interconnected
cannot exceed 6.0 amps, with a maximum distance
between luminaires not exceeding 3 feet.
Warranty - All components, except lamps, are
warranted to perform for the life of the original
installation.
Ordering Information
Sample Catalog No: SQ111 - 120 - AL - SQC
Each individual or string of interconnected Slique T2 luminaires require a Power Feed. Select below.
120
NOM.
LENGTH
Model Number
18-15/16” SQ111 (1) FM11 T2 Fluorescent
Voltage
120
22-15/16” SQ113 (1) FM13 T2 Fluorescent
36-15/16” SQ211 (2) FM11 T2 Fluorescent
Finish
(standard color is WHG)
WHG White Glossy
BLKG Black Glossy
AL Aluminum
44-15/16” SQ213 (2) FM13 T2 Fluorescent
Sample Catalog No: SQ-DWR - 120 - AL
120
NOM.
LENGTH
Power Feed Style
4-7/8”
SQ-DWR Direct wire power feed, right end
4-7/8”
SQ-DWL Direct wire power feed, left end
3-1/2”
SQ-CSR Portable power feed, right end (with 6ft. cordset)
3-1/2”
SQ-CSL Portable power feed, left end (with 6ft. cordset)
11500 Melrose Avenue Franklin Park, Illinois 60131
Phone: 847-451-0700 Toll-Free: 1-866-50ALKCO Fax: 847-451-7512 www.alkco.com 06/10
©2010 Alkco Lighting. All rights reserved. Product designs protected by copyright.
We reserve the right to change details of design, materials and finishes.
Voltage
120
Options
FC1
In-line connector for end-to-end connections
CCW1
White 12-36” coiled interconnect cord
CCB1 Black 12-36” coiled interconnect cord
SCW1 White 6” straight interconnect cord
SCB1 Black 6” straight interconnect cord
41K
4100K lamp substituted for 3000K lamp
SQGSF-4
4’ Fascia extrusion for mounting to 3/8” or 1/2” glass shelf
SQGSF-8
8’ Fascia extrusion for mounting to 3/8” or 1/2” glass shelf
1
Finish
(standard color is WHG)
WHG White Glossy
BLKG Black Glossy
AL Aluminum
Order one connector or interconnect cord for each connection point.
A10.0
Project
Slique T2
Type
3/4˝ Undercabinet/Display Light
T2 Fluorescent
SQ
Dimensional Data
1-7/8”
(47.6mm)
Left End
Power Feed
17/32”
1-3/4”
(13.5mm)
(44.5mm)
1-3/4”
Left
End*
Right
End*
Lens
(44.5mm)
3/4”
(19.1mm)
Cross Section
4-1/4”
(108.0mm)
Optional Glass
Shelf Fascia
4-1/2”
(114.3mm)
(3/8” - 1/2” shelf thickness)
SQ111
18-15/16”
SQ113
22-15/16”
SQ211
36-15/16”
* Left End Power Feed illustrated in drawing above. Left or Right End Power Feed Available.
Specify only one Power Feed for each fixture (or run of fixtures).
Alternate Remote Mounting of
Power Feed with Interconnect Cord
Lens
(465.1mm)
(566.7mm)
(922.3mm)
44-15/16”
SQ213
(1227.1mm)
1-5/32”
1-3/4”
3/4”
(44.5mm) (29.4mm)
(19.1mm)
4-1/4”
4-1/4”
Power Feed
(End View)
(108.0mm)
(108.0mm)
5”
4-1/2”
(127.0mm)
(114.3mm)
Portable Power Feed
Direct Power Feed
Photometric Data
SQ113
SQ213
(1) 13W T2 Fluorescent
860 lumens per lamp
(2) 13W T2 Fluorescent
860 lumens per lamp
Report No.: ITL51988
Efficiency: 66.9%
Report No.: ITL51989
Efficiency: 68.1%
90˚
90˚
75˚
75˚
150
80
60˚
60˚
300
160
45˚
45˚
450
240
0˚
15˚
30˚
LEGEND:
0-deg:
90-deg:
180-deg:
0˚
LEGEND:
0-deg:
90-deg:
180-deg:
15˚
30˚
ELECTRICAL DATA
Lamp Wattage 11W
Input Watts 14
Max. Amps .11
Power Factor >.95
THD <15%
13W
16
.13
>.95
<15%
277V, 347V and dimming ballasts not available
(2) 11W (2)13W
28
32
.23
.27
>.95
>.95
<15%
<15%
Hg Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small amounts of mercury. Such lamps
are labeled “Contains Mercury” and/or with the symbol “Hg”. Lamps that contain mercury must be disposed of in accordance
with local requirements. Information regarding lamp recycling and disposal can be found at www.lamprecycle.org
11500 Melrose Avenue Franklin Park, Illinois 60131
Phone: 847-451-0700 Toll-Free: 1-866-50ALKCO Fax: 847-451-7512 www.alkco.com 06/10
©2010 Alkco Lighting. All rights reserved. Product designs protected by copyright.
We reserve the right to change details of design, materials and finishes.
A10.0
Project
Slique T2
Type
3/4˝ Undercabinet/Display Light
T2 Fluorescent
SQ
Photometric Data
SQ113
CO-EFFICIENTS OF UTILIZATION
(1) 13W T2 Fluorescent
860 lumens per lamp
rc
rw
Report No.: ITL51988
Efficiency: 66.9%
90˚
75˚
80
60˚
160
45˚
240
0˚
15˚
30˚
LEGEND:
0-deg:
90-deg:
180-deg:
RCR 0
1
2
3
4
5
6
7
8
9
10
50
50 30 10
30
50 30 10
10
50 30 10
0
0
78
70
63
57
52
48
44
41
38
35
33
76
68
61
55
50
46
42
39
36
34
32
72
61
52
45
40
36
32
29
26
24
22
68
57
49
43
38
34
30
27
25
23
21
68
55
46
39
34
29
26
23
21
19
17
64
54
46
41
36
32
29
26
24
22
20
64
51
41
34
29
25
22
19
17
15
14
62
49
40
33
27
23
20
18
15
14
12
ZONAL LUMEN SUMMARY
78
66
57
50
44
39
35
31
28
26
24
78
63
52
44
37
32
28
25
22
20
18
78
60
48
39
32
28
24
21
18
16
15
Horizontal Angle
0°
120
135
182
221
239
232
203
157
127
104
88
74
43
45°
120
130
156
183
198
192
168
130
94
65
53
42
22
90°
120
120
116
108
98
83
63
39
14
2
0
0
0
135°
120
114
108
102
91
67
41
19
7
1
0
0
0
180°
120
113
109
105
87
54
26
11
5
1
0
0
0
(2) 13W T2 Fluorescent
860 lumens per lamp
rc
rw
75˚
150
60˚
300
45˚
450
0˚
15˚
30˚
LEGEND:
0-deg:
90-deg:
180-deg:
11500 Melrose Avenue Franklin Park, Illinois 60131
Phone: 847-451-0700 Toll-Free: 1-866-50ALKCO Fax: 847-451-7512 www.alkco.com 06/10
©2010 Alkco Lighting. All rights reserved. Product designs protected by copyright.
We reserve the right to change details of design, materials and finishes.
RCR 0
1
2
3
4
5
6
7
8
9
10
I
72
58
48
41
35
30
27
24
21
19
17
72
56
45
37
31
26
23
20
18
16
14
68
53
43
36
30
26
22
19
17
15
14
64
52
44
37
32
28
25
22
20
18
16
Lumens % Lamp % Fixt.
0-30
113
13.1
19.6
0-40
199
23.1
34.6
0-60
382
44.4
66.3
0-90
534
62.1
92.8
90-120
38
4.4
6.5
90-130
40
4.7
7.0
90-150
41
4.8
7.2
90-180
41
4.8
7.2
0-180
575
66.9
100.0
Effective floor cavity reflectance=20%
70
70 50 30 10
50
50 30 10
30
50 30 10
10
50 30 10
0
0
80
72
65
59
53
49
45
42
39
36
34
78
69
62
56
51
47
43
40
37
35
33
73
62
54
47
41
37
33
30
27
25
23
69
59
51
44
39
35
31
28
26
24
22
69
57
47
40
35
30
27
24
21
19
18
65
55
48
42
37
33
30
27
25
23
21
64
50
41
34
29
24
21
18
16
14
13
ZONAL LUMEN SUMMARY
80
68
58
51
45
40
36
32
29
27
24
80
64
53
45
38
33
29
26
23
21
19
80
61
49
40
34
29
25
22
19
17
15
78
66
57
49
44
39
35
31
28
26
24
Horizontal Angle
0°
260
294
385
459
487
455
386
310
245
196
165
133
72
76
58
47
38
32
27
23
20
18
16
14
80
70 50 30 10
CANDLEPOWER DISTRIBUTION
Vertical
Angle
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
95°
105°
76
61
51
43
36
32
28
25
22
20
18
Zone
CO-EFFICIENTS OF UTILIZATION
90˚
76
64
55
48
42
38
34
30
28
25
23
CANDLEPOWER DISTRIBUTION
Vertical
Angle
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
95°
105°
Effective floor cavity reflectance=20%
70
70 50 30 10
SQ213
Report No.: ITL51989
Efficiency: 68.1%
I
80
70 50 30 10
45°
260
284
337
387
409
394
330
255
187
127
102
80
40
90°
260
261
252
237
214
182
138
82
31
4
0
0
0
135°
260
246
229
215
188
140
84
42
17
3
0
0
0
78
63
52
44
38
33
29
25
23
21
19
78
60
48
39
33
28
24
21
19
17
15
Zone
180°
260
241
228
216
178
116
57
24
10
3
0
0
0
73
60
50
42
36
31
28
25
22
20
18
73
57
46
38
32
27
24
21
18
16
15
Lumens % Lamp % Fixt.
0-30
241
14.0
20.5
0-40
420
24.4
35.9
0-60
791
46.0
67.6
0-90
1093
63.6
93.4
90-120
69
4.0
5.9
90-130
74
4.3
6.3
90-150
77
4.5
6.6
90-180
77
4.5
6.6
0-180
1171
68.1
100.0
69
55
44
37
31
27
23
20
18
16
15
65
54
45
39
33
29
26
23
21
19
17
65
52
43
36
30
26
23
20
18
16
14

Similar documents