Add-ons for SIMATIC PCS 7
Transcription
Add-ons for SIMATIC PCS 7
© Siemens AG 2013 Add-ons for the SIMATIC PCS 7 Process Control System SIMATIC PCS 7 Catalog ST PCS 7 AO Edition 2013 Answers for industry. © Siemens AG 2013 Related catalogs SIMATIC SIMATIC PCS 7 Process Control System ST PCS 7 E86060-K4678-A111-B8-7600 SIMATIC Migration solutions with the SIMATIC PCS 7 Process Control System ST PCS 7.2 SITRAIN Training for Automation and Industrial Solutions ST 70 Products for Automation and Drives Interactive Catalog DVD: E86060-D4001-A510-D2-7600 SIMATIC HMI / ST 80/ST PC PC-based Automation Human Machine Interface Systems PC-based Automation Industry Mall Information and Ordering Platform in the Internet: E86060-K4680-A101-B9-7600 www.siemens.com/industrymall E86060-K6710-A101-B7-7600 ITC Only available in German E86060-K6850-A101-C3 E86060-K4670-A101-B3-7600 Industrial Communication SIMATIC NET FI 01 E86060-K6201-A101-B5-7600 PDF (E86060-K4678-A131-A5-7600) SIMATIC Products for Totally Integrated Automation and Micro Automation Process Automation Field Instruments for Process Automation IK PI CA 01 © Siemens AG 2013 SIMATIC PCS 7 Add-ons for the SIMATIC PCS 7 Process Control System Catalog ST PCS 7 AO · 2013 Information and management systems 1 Advanced Process Control 2 Industry-specific applications 3 Cement industry, Mining industry, Telecontrol, Process Analytical Technology Operator control and monitoring 4 Libraries/blocks/tools 5 Distributed I/O on PROFIBUS 6 Simulation 7 Diagnostics 8 Refer to the Industry Mall for current updates of this catalog: www.siemens.com/industrymall Laboratory automation 9 The products contained in this catalog can also be found in the Interactive Catalog CA 01. Order No.: E86060-D4001-A500-D2-7600 Switchgear/controlgear automation 10 Energy management 11 Architecture and configuration 12 The products and systems described in this catalog are manufactured/distributed under application of a certified quality management system in accordance with DIN EN ISO 9001 (Certified Registration No. 1323-QM). The certificate is recognized by all IQNet countries. Supersedes: Catalog ST PCS 7.1 · 2011 Please contact your local Siemens branch © Siemens AG 2013 Automation Firewall, Cabinets, Time synchronization Appendix Printed on paper from sustainably managed forests and controlled sources. www.pefc.org 13 © Siemens AG 2013 2 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Answers for industry. Siemens Industry answers the challenges in the manufacturing and the process industry as well as in the building automation business. Our drive and automation solutions based on Totally Integrated Automation (TIA) and Totally Integrated Power (TIP) are employed in all kinds of industry. In the manufacturing and the process industry. In industrial as well as in functional buildings. Siemens offers automation, drive, and low-voltage switching technology as well as industrial software from standard products up to entire industry solutions. The industry software enables our industry customers to optimize the entire value chain – from product design and development through manufacture and sales up to after-sales service. Our electrical and mechanical components offer integrated technologies for the entire drive train – from couplings to gear units, from motors to control and drive solutions for all engineering industries. Our technology platform TIP offers robust solutions for power distribution. The high quality of our products sets industry-wide benchmarks. High environmental aims are part of our eco-management, and we implement these aims consistently. Right from product design, possible effects on the environment are examined. Hence many of our products and systems are RoHS compliant (Restriction of Hazardous Substances). As a matter of course, our production sites are certified according to DIN EN ISO 14001, but to us, environmental protection also means most efficient utilization of valuable resources. The best example are our energy-efficient drives with energy savings up to 60 %. Check out the opportunities our automation and drive solutions provide. And discover how you can sustainably enhance your competitive edge with us. Siemens ST PCS 7 AO · 2013 3 © Siemens AG 2013 (53²(QWHUSULVH5HVRXUFH3ODQQLQJ 3/0²3URGXFW/LIHF\FOH0DQDJHPHQW 0DQDJHPHQW/HYHO 3URGXFW'HVLJQ 3URGXFWLRQ3ODQQLQJDQG6LPXODWLRQ 'DWD0DQDJHPHQW 0(6²0DQXIDFWXULQJ([HFXWLRQ6\VWHPV 6,0$7,&,7 2SHUDWLRQV/HYHO 0DLQWHQDQFH $VVHW0DQDJHPHQW 6,0$7,&3&6 2SHUDWRU6\VWHP (QHUJ\ 0DQDJHPHQW (QJLQHHULQJ 6WDWLRQ 7,$3RUWDO &RQWURO/HYHO 6,0$7,&3&6 $XWRPDWLRQ 6\VWHPV 6,180(5,. &RPSXWHU1XPHULF&RQWURO 6,027,21 0RWLRQ&RQWURO 6,0$7,&1(7 ,QGXVWULDO &RPPXQLFDWLRQ 6,0$7,&&RQWUROOHUV 0RGXODU3&EDVHG )LHOG/HYHO 352),%863$ 3URFHVV,QVWUXPHQWDWLRQ 7RWDOO\ ,QWHJUDWHG $XWRPDWLRQ 6,0$7,&'LVWULEXWHG,2 6,0$7,&,GHQW ,QGXVWULDO,GHQWLÀFDWLRQ +$57 ,2/LQN Setting standards in productivity and competitiveness. Totally Integrated Automation. 4 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 TIA is characterized by its unique continuity. It provides maximum transparency at all levels with reduced interfacing requirements – covering the field level, production control level, up to the corporate management level. With TIA you also profit throughout the complete life cycle of your plant – starting with the initial planning steps through operation up to modernization, where we offer a high measure of investment security resulting from continuity in the further development of our products and from reducing the number of interfaces to a minimum. 3ODQW(QJLQHHULQJ &2026 (WKHUQHW 6,0$7,&:LQ&& 6&$'$6\VWHP The unique continuity is already a defined characteristic at the development stage of our products and systems. ,QGXVWULDO(WKHUQHW 6,0$7,&+0, +XPDQ0DFKLQH,QWHUIDFH The result: maximum interoperability – covering the controller, HMI, drives, up to the process control system. This reduces the complexity of the automation solution in your plant. You will experience this, for example, in the engineering phase of the automation solution in the form of reduced time requirements and cost, or during operation using the continuous diagnostics facilities of Totally Integrated Automation for increasing the availability of your plant. 6,5,86,QGXVWULDO&RQWUROV 352),1(7 ,QGXVWULDO(WKHUQHW 352),%86 6,1$0,&6'ULYH6\VWHPV /RZ9ROWDJH'LVWULEXWLRQ $6,QWHUIDFH .1;*$00$LQVWDEXV 7RWDOO\ ,QWHJUDWHG 3RZHU 6,027,&60RWRUV Thanks to Totally Integrated Automation, Siemens provides an integrated basis for the implementation of customized automation solutions – in all industries from inbound to outbound. Siemens ST PCS 7 AO · 2013 5 © Siemens AG 2013 Totally Integrated Power: Future-proof power supply from one source. 6 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Software tools, products, systems and support for integrated electrical power distribution Energy Management/ Energy Transparency Operation & Monitoring Load management Load curves Forecast Maintenance Substation Distribution Maintenance task Status reporting/ failure management Protocols Power Quality DATE: Cost center EMPLOYEE COST CENTER PAY PERIOD BEGINNING PAY PERIOD ENDING DATE SUN MON TUE WED THUR FRI SUN MON TUE WED THUR FRI SAT SUN TOTAL IN OUT IN OUT OVERTIME TOTAL HOURS DATE SAT SUN TOTAL IN OUT U I cos o P W IN Hall 1 Distribution 3 Process/ industrial automation Products & Systems Infeed II Renewables Medium voltage with protection technology Air conditioning system checkup Replacing circuit breaker contacts Replacing meters OUT OVERTIME TOTAL HOURS central ON OFF local ON OFF tripped Transformer DATE SUN MON TUE WED THUR FRI SAT SUN TOTAL IN OUT IN OUT Building automation OVERTIME TOTAL HOURS Low voltage with protection and measuring technology ≤ 110 kV Planning Software Tools The power supply system acts like a “vital artery”, forming the basis for the reliable and efficient functioning of all electrically operated building installations. Electrical power distribution therefore requires integrated solutions. Our answer: Totally Integrated Power (TIP). This includes software tools and support for planning and configuration and a complete, optimally aligned product and system portfolio for integrated power distribution from medium-voltage switchgear right to socket outlets. Network dimensioning with SIMARIS design Space requirements and budget calculation with SIMARIS project The power distribution products and systems can be interfaced to building or industrial automation systems (Total Building Solutions or Totally Integrated Automation) via communication-capable circuit breakers and components, allowing the full potential for optimization that an integrated solution offers to be exploited throughout the project cycle – from planning right through to installation and operation. Visualization of device characteristics with SIMARIS curves Get more information: www.siemens.com/tip www.siemens.com/simaris www.siemens.com/specifications Siemens ST PCS 7 AO · 2013 7 © Siemens AG 2013 Add-ons for SIMATIC PCS 7. As an important component of Totally Integrated Automation (TIA), the SIMATIC PCS 7 process control system is integrated seamlessly in a comprehensive range of perfectly matched products, systems, and solutions for all hierarchy levels of industrial automation – from the enterprise management level, to the control level, all the way down to the field level. Thus the complete process chain at a production location can be automated, and not just the actual production process - from the inbound logistics (material supply), through the primary process and downstream secondary processes (filling, packaging), down to the outbound logistics (storage). The exceptionally powerful and versatile SIMATIC PCS 7 process control system is an ideal basis for the cost-effective implementation and efficient operation of control systems. Its functionality can be expanded through the seamless integration of technology components for specific automation tasks. Uniformity, modularity, flexibility, scalability, and the openness of SIMATIC PCS 7 additionally provide optimal prerequisites for integrating supplementary components and solutions into the process control system in an applicative manner and thus extend and round off its functionality. Since SIMATIC PCS 7 was launched on the market, we at Siemens as well as our external partners have developed a wide range of supplementary components which we refer to in short as PCS 7 add-on products. 8 Siemens ST PCS 7 AO · 2013 PCS 7 add-on products are software packages and hardware components that are optimally adapted to the respective field of application and thus enable costeffective use of SIMATIC PCS 7 for special automation tasks. With this catalog, we wish to help you in finding products for your specific task. © Siemens AG 2013 Siemens ST PCS 7 AO · 2013 9 © Siemens AG 2013 Product responsibility, conditions of use The responsibility for a PCS 7 add-on product generally rests with the product manager in each case. The address of the product manager can be found in the "More information" section. This gives you direct access to the appropriate specialists. All SIMATIC PCS 7 add-on products entitle you to worldwide hotline support from our Technical Support center. Information on central technical support as well as contact addresses can be found in the appendix to this catalog; the general terms and conditions apply. External SIMATIC PCS 7 partners organize the sale and delivery of their products independently. Their own terms and conditions of business and delivery apply. Corresponding information can be obtained from the addresses given in the "More information" section. Siemens AG accepts no liability and offers no warranty for the products of external SIMATIC PCS 7 partner companies. The catalog contains hyperlinks to the web sites of third party companies. Siemens cannot be held responsible for the contents of these web sites, nor does Siemens adopt these web sites and their contents as their own. You therefore use these links at your own risk. Since Siemens is not responsible for linked contents and information on the web sites of third parties, this information is not checked by Siemens. 10 Siemens ST PCS 7 AO · 2013 Pricing information Internet Pricing information for the products with Order Nos. in this catalog can be obtained via the interactive Catalog CA 01, the Industry Mall on the Internet, or on request from your local Siemens partner. The Catalog ST PCS 7 AO can also be downloaded as a PDF file from the Internet. Pricing information for the products without an order number can be provided on request by the responsible add-on partners listed under "More Information". Marking for SIMATIC PCS 7 V8 The Information and Download Center of Siemens Industry Automation and Drive Technologies can be accessed from the SIMATIC PCS 7 web site or at: www.siemens.com/simatic/ printmaterial Additional information is available on the SIMATIC PCS 7 web site on the Internet at: www.siemens.com/simatic-pcs7 The add-on products offered in this catalog are specified for the SIMATIC PCS 7 versions 7 and 8. SIMATIC PCS 7 versions up to V6 are no longer supported by this catalog. The possible application is specified for each product. The information V7 or V8 always refers to all versions 7 or 8. Otherwise the version is explicitly defined, e.g. V7.1. Products suitable for SIMATIC PCS 7 V8 are additionally identified by the following logo: PCS 7 Add-on fit for SIMATIC PCS 7 V8 1 © Siemens AG 2013 Information and Management Systems 1/2 PIMS-PCS 7-CONNECT: Working together with PIMS systems 1/4 PCS 7 OCS: Open interface for connection of third-party applications 1/6 PLSDOC RE: Documentation updating system for SIMATIC PCS 7 1/7 ACRON 7: Long-term archiving and logging for SIMATIC PCS 7 1/8 versiondog: Data management for SIMATIC PCS 7 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Information and Management Systems ■ Overview ■ Function PCS 7 Add-on PI-PCS 7-CONNECT fit for SIMATIC PCS 7 V8 PI-CONNECT OPC+ interface The products described here (interfaces and tools) support economic cooperation between SIMATIC PCS 7 including SIMATIC BATCH and the following plant information management systems (PIMS): • PI System from OSIsoft (PI-PCS 7-CONNECT) • aspenOne from AspenTech (aspenOne-PCS 7-CONNECT) A plant information management system is suitable for: • Short-term and long-term archiving beyond the limits of companies and plants • Evaluation and presentation of process and production data The interfaces and tools provide the best possible combination of PI System and aspenOne with SIMATIC PCS 7. They feature high flexibility, performance and safety. They also support redundant systems and archive recovery concepts, e.g. in the event of interferences in a connection. We can additionally offer tailored, scalable support and services for efficient implementation and maintenance of these interfaces and tools. Information on support and services as well as manufacturer declarations are available on request (for contact address, see "Further information"). PI-CONNECT OPC+ reads the process variables cyclically from SIMATIC PCS 7 and saves these in the PI long-term archive. The interface is operated on a separate interface PC on the terminal bus of the SIMATIC PCS 7 process control system, and supports: • Redundancy functionality of the SIMATIC PCS 7 OS server • Concurrent time stamp treatment • Archive recovery • Failover online (available soon) The PI-CONNECT OPC+ interface can be used together with SIMATIC PCS 7 V7 and V8. It can use the following interfaces for communication with SIMATIC PCS 7: • OpenPCS 7 interface • OPC interface PI-CONNECT ALARM interface The PI-CONNECT ALARM interface can be used to transfer messages from the SIMATIC PCS 7 process control system and/or other sources to the PI archive. Since most of the requirements and special features to be considered are projectspecific, PI-CONNECT ALARM cannot be offered as a standard product but only as an individual solution based on the standard interface. PI-CONNECT ALARM can be used together with SIMATIC PCS 7 V7 and V8. SAP PIMS server Office LAN (Ethernet) OS / Batch / Route Control Clients PIMS interface with Connect Tools OS single station Terminal bus, single/redundant Ethernet OS / Route Control server Engineering station Batch/archive server Industrial Ethernet, single/redundant Standard automation systems 1/2 Siemens ST PCS 7 AO · 2013 High-availability automation systems Safety-oriented automation systems G_PCS7_XX_00174 1 PIMS-PCS 7-CONNECT: Working together with PIMS systems © Siemens AG 2013 Information and Management Systems PIMS-PCS 7-CONNECT: Working together with PIMS systems ■ Function (continued) PI-CONNECT SIMATIC BATCH interface This interface transmits data from SIMATIC BATCH to the PI batch subsystem. Together with the PI-CONNECT OPC+ interface, reports and evaluations based on batch data and process data can be implemented in the PI system. Additional functional properties of PI-CONNECT SIMATIC BATCH include: • Archive recovery • Support of hierarchical recipes of SIMATIC BATCH PI-CONNECT SIMATIC BATCH can be used together with SIMATIC BATCH V7 and V8. ■ More information Siemens AG Industry Sector Customer Services Division Mannheim Office Phone: +49 621 456-3315 Fax: +49 621 456-3334 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.com/mis-pcs7 PI-CONNECT CONFIG tool PI-CONNECT CONFIG is able to work together with PICONNECT OPC+, and with the OPC interface of OSIsoft. The tool provides support for effective creation and easy updating of the PI system project for the SIMATIC PCS 7 link. It provides CSV files for importing into the PI configuration database. It can be used equally for initial configuration of the PI system and for tracking of SIMATIC PCS 7 configuration modifications in the PI system. PI-CONNECT CONFIG can be used together with SIMATIC PCS 7 V7 and V8. aspenOne-PCS 7-CONNECT Batch.21-CONNECT SIMATIC BATCH interface This interface transmits data from SIMATIC BATCH to the Batch.21 system and supports you with functions such as archive recovery. Thus reports and evaluations based on batch data and process data can be implemented in the AspenTech system. Batch.21 CONNECT SIMATIC BATCH can be used together with SIMATIC BATCH V7 and V8. IP.21-CONNECT CONFIG tool IP.21-CONNECT CONFIG provides support for effective creation and easy updating of the IP.21 system project for the SIMATIC PCS 7 link. The tool provides CSV files for importing into the IP.21 configuration database. It can be used equally for initial configuration of the IP.21 system and for tracking of SIMATIC PCS 7 configuration modifications in the IP.21 system. IP.21-CONNECT CONFIG can be used together with SIMATIC PCS 7 V7 and V8. Siemens ST PCS 7 AO · 2013 1/3 1 © Siemens AG 2013 Information and Management Systems ■ Overview ■ Application PCS 7 Add-on ERP SAP fit for SIMATIC PCS 7 V8 MES PIMS SQL database Web MATLAB Simulink Process values Process archives Message archives PCS 7 OCS PCS 7 AS PCS 7 AS LAN PCS 7 OCS PCS 7/TMOS server OS server PCS 7 plant bus Microsoft Excel CS 275 PCS 7 AS TELEPERM M TELEPERM M AS AS G_PCS7_XX_00013 1 PCS 7 OCS: Open interface for connection of third-party applications Using PCS 7 OCS you can simply link, for example, the following external applications/systems to SIMATIC PCS 7: • SAP and other ERP systems from the corporate management level • MES systems for production and corporate management • PIMS (Plant Information Management Systems) to gather operating data • Simulation and optimization tools, e.g. for monitoring of controller performance or for application of Advanced Process Control methods • External database applications for long-term archiving and data analysis for more than a single plant • Web browser for presentation of production information (online data, message lists, trends) • Office applications such as Microsoft Excel, for example, for generation of reports • Process control systems and PLCs from other vendors ■ Design As an alternative to the OpenPCS 7 system interface, the SIMATIC PCS 7 can also use the PCS 7 OCS open data interface for data exchange with applications or systems to allow process data evaluation and production planning. The PCS 7 OCS is installed directly on the PCS 7 OS server or the PCS 7/TM-OS server for TELEPERM M migration. Neither additional hardware nor any special configuration of the associated OS server is necessary. By using PCS 7 OCS, external applications and systems are able to read out configuration and process variables as well as the process value and message archives of the SIMATIC PCS 7 process control system via network. If these external applications/systems also have write privileges, they can additionally transfer data to the process control system via network. It is then possible e.g. to visualize and process transport orders as well as production or inventory data of an ERP (Enterprise Resource Planning) system using SIMATIC PCS 7. Two PCS 7 OCS licenses are required for connecting redundant third-party systems, one each for the two OS servers of a redundant pair of servers. Identical information is then available in parallel via the two PCS 7 OCS interfaces of this pair of servers. In contrast to the OpenPCS 7 interface based on the OPC specifications, the PCS 7 OCS interface uses the platformindependent ACPLT/KS communication standard for communication between the applications, and not Microsoft COM/DCOM technology. This allows stable, firewall-compatible TCP/IP communication via a limited number of statically defined network ports. PCS 7 OCS enables external applications/systems to indirectly find all instances of blocks or variables in the process control system by means of their type and to carry out further selection using filter criteria. Thus a certain group of parameter types can be specifically read out or external data recording can be automatically configured with automatic adaptation to changes in the configuration of the process control system. Note: PCS 7 OCS can be used together with SIMATIC PCS 7 V7 and V8. 1/4 Siemens ST PCS 7 AO · 2013 Powerful PCS 7 OCS communication based on the TCP/IP protocol for data exchange between OS server and application/ system is also possible without problems in distributed networks in which the access is limited by means of a firewall. © Siemens AG 2013 Information and Management Systems PCS 7 OCS: Open interface for connection of third-party applications ■ Function ■ Selection and ordering data The PCS 7 OCS interface is exceptionally suitable for linking external applications/systems to SIMATIC PCS 7 with the assistance of autoconfiguration functions. A PCS 7 OCS license provides authorization for: • Reading and writing all variables of an OS server • Reading process value archives and alarm logs SIMATIC PCS 7 OCS V3.3 incl. SP1 Open communication server for data exchange between SIMATIC PCS 7 OS server and third-party system/application, executes with SIMATIC PCS 7 V7.0, V7.1 and V8.0, single license for 1 installation LeiKon GmbH offers the following standard applications for the SIMATIC PCS 7 connection via PCS 7 OCS in addition to the data interface (see under "More info" for the contact address for detailed information and ordering). Engineering software with runtime license for one PCS 7 OS server, one language (German), software class B Additive standard applications from LeiKon GmbH • Web server "Web meets Production" The Web server is used to provide individually designed Web pages with which current and historical data of the SIMATIC PCS 7 process control system can be displayed, for example, key performance indicators (KPI), production states or production statistics • PIMS and database coupler "KSHistBuilder" The KSHistBuilder can be used to cyclically transfer archived or online data from SIMATIC PCS 7 to a standard SQL database. Existing archives are automatically detected and transferred cyclically to the database. Configuration is not required. Brief communication failures do not result in a loss of data. An identical functionality is also available for connecting SIMATIC PCS 7 to standard plant information management systems (PIMS). • Microsoft Excel add-in "Excel meets Production" With this expansion, process and archive data of SIMATIC PCS 7 can be read manually or cyclically into Microsoft Excel. Format templates can be freely defined. Order No. 6DL5 405-8AD33-0XA0 Delivery package: Software and documentation on CD and certificate of license Additive standard applications for data exchange with the SIMATIC PCS 7 OS server via SIMATIC PCS 7 OCS, e.g. • Web server "Web meets production" • PIMS and database coupler "KSHistBuilder" • Microsoft Excel add-in "Excel meets production" On request from LeiKon GmbH ■ More information LeiKon GmbH Kaiserstr. 100 52134 Herzogenrath Germany Tel.: +49 2407 95 17 330 Fax: +49 2407 95 17 339 E-mail: [email protected] Additional information is available on the Internet at: www.leikon.de Siemens ST PCS 7 AO · 2013 1/5 1 © Siemens AG 2013 Information and Management Systems 1 PLSDOC RE: Documentation updating system for SIMATIC PCS 7 ■ Overview ■ Function PCS 7 Add-on fit for SIMATIC PCS 7 V8 Application computer - PLSDOC RE front end - PLSDOCTracker for scanning of OPC gateway, communication with database - Memory location PLSDOC RE - Memory location Support&Help for access of the OS Application computer Operator station Engineering station PLSDOC RE database SCALANCE X Terminal bus: Industrial Ethernet Redundant OS server OPC gateway Monitoring of OPC variables for changes PLSDOC RE system overview The PLSDOC RE documentation updating system is provided for documentation of SIMATIC PCS 7 systems throughout the complete lifecycle of the system and for integration of changes. System support engineers profit from the high availability of system know-how and are provided with support for quality assurance. PLSDOC RE immediately aligns the system documentation with the current parameters, e.g. limits, control parameters, interlocking information, and step sequences of the process control system. Changes are automatically recorded in change reports and new revisions generated. PLSDOC RE provides information for system support engineers in the form of standardized project documents, e.g.: • Limit lists, change reports • Step sequence documentation • IB/FAT reports • Loop check reports • Quantity frameworks • Procedural instructions for alarm management Note: PLSDOC RE can be used together with SIMATIC PCS 7 V7 and V8. ■ Benefits 7 Standardized documentation of process objects and step sequences 7 Automatic comparison of data in process control system and feature specification - Changes to customized parameters are completely documented, e.g. limits, control parameters, measuring ranges, interlocking information, and step sequences 7 Provision of standardized documents for system configuration and support 7 Integration of feature specification into the operator systems - Information directly available to support personnel 1/6 Siemens ST PCS 7 AO · 2013 • Monitoring of redundant pairs of servers in the context of documentation updating, and switching over to the redundant server upon failure of the active server • Buffering of the information between OS server and PLSDOC RE means that no change information is lost which is produced prior to the establishment of a connection to the OS server • Generation of HTML documents for every process variable • Direct calling of generated HTML documents can be integrated into the process images • Referencing of other process variables can be directly called using hyperlinks • Management of information on peripherals (computers, printers, software licenses etc.) • Recording of information independent of process objects, e.g. information on maintenance work and measures taken in the event of faults ■ Technical specifications System requirements • Microsoft Windows XP, Windows Vista, Windows 7, Windows 8; in each case x86 and x64 • Microsoft Windows Server 2003, 2008, 2008 R2, 2012; in each case x86 and x64 Application computer • 2 GB RAM, 5 GB hard disk Database computer • Microsoft SQL Server 2005, 2008, 2008 R2, 2012 • 4 GB RAM, 100 GB hard disk ■ More information iMes Solutions GmbH Mehringerstr. 2 84489 Burghausen Germany Tel.: +49 8677 96180 E-mail: [email protected] Additional information is available on the Internet at: www.plsdoc.de © Siemens AG 2013 Information and Management Systems ACRON 7: Long-term archiving and logging for SIMATIC PCS 7 ■ Overview ACRON evaluation PCS 7 Add-on fit for SIMATIC PCS 7 V8 Reporter Graph1 OCX ACRON database Alert OCX External evaluation Maintenance and servicing Configuration Configuration Reporter Microsoft Excel Process values Laboratory values Manual values Data recording Process 1 Designer Provider Process 2 Process n ACRON is a product for plant optimization, energy monitoring, long-term archiving with data compression and recording. It supports you when fulfilling mandatory documentation requirements. ACRON was originally designed for special requirements in environmental technology, but has also proven successful in many different industries in the meantime. ACRON is also suitable for the high requirements encountered in the water/ wastewater/environmental industry (e.g. ATV M260 in Germany). The current version ACRON 7 offers an exceptional price/performance ratio, and is impressive in operation thanks to high availability, running reliability, and data integrity. Simple configuration, easy handling and high flexibility are further exceptional features. ACRON 7 is scalable from a small single-user system up to a networked client/server system for large applications. The interfaces of ACRON 7 are matched to the SIMATIC PCS 7 process control system. Certain modules can be integrated as OCX in SIMATIC PCS 7. A Web application and a Microsoft Excel add-in are also available. ACRON 7 is currently available in English, German, Italian, Spanish, French, Russian, and Portuguese. Note: ACRON 7 can be used together with SIMATIC PCS 7 V7 and V8. ■ Design The following modules are components of ACRON 7: • Database: Up to 100 000 data points, time-based or change-dependent recording, arithmetic operations, high performance with resolution in millisecond range, high data security due to TLC (Three Level Cache) • Provider: Data acquisition from any sources with telecontrol link and very high data security • Reporter: Convenient operator interface for printing of reports and logs with input facility for manual laboratory values SAP OPC server ODBC server Compressed, calculated data - WinCC, SIMATIC PCS 7 - OPC DA und AE - ASCII, CSV, XML - DDE - ODBC, ... • Graph: User-friendly presentation and analysis of measured values and statistical values in trends • Fault and maintenance module: Generation of all required fault and message reports as well as comprehensive statistics • AC Job: Administration module for automatic printing of reports including sending by e-mail • Data Collect: Combination of any values from various ACRON applications • Microsoft Excel Add-In: Convenient access to all data • AC Mirror: Up to 8-fold database redundancy • ACRON Web: Web-based analyses and scans can read the complete ACRON database. An ACRON Web client permits reading of all reports and also the graphic display of data. ■ More information VIDEC GmbH Osterdeich 108 28205 Bremen Germany Tel.: +49 421 339500 Fax: +49 421 3379561 E-mail: [email protected] Additional information is available on the Internet at: www.acron7.com Siemens ST PCS 7 AO · 2013 1/7 1 © Siemens AG 2013 Information and Management Systems 1 versiondog: Data management for SIMATIC PCS 7 ■ Overview ■ Design PCS 7 Add-on fit for SIMATIC PCS 7 V8 versiondog is extremely easy to integrate in a SIMATIC PCS 7 system. No additional drivers are required, and no special settings or configurations in the SIMATIC PCS 7 project either. The server for the central data storage is set up on a separate computer. The client, which can also be executed without installation, does not carry out any write operations on Windows directories or read/write operations on the Windows registry. System administration is thus possible from any PC-based station. ■ Function versiondog is a powerful data management system which supports the complete lifecycle of a SIMATIC PCS 7 system from configuration through commissioning and operation up to modernization. You can use versiondog to administer your projects in a central data storage system with access control, for automatic assignment of versions, and for documentation and comparison. Smart Compare shows the differences between two versions in a clearly understandable form. Differences between two CFC or SFC charts are marked in color in a graphic comparison. The audit trail of versiondog exactly shows changes, including information on who, when, what and why. versiondog can automatically verify at regular intervals whether the production is being carried out with the currently released program version and immediately signals any deviations. The change processes regulated and systemized with versiondog conform with the directives ISO 900x, FDA 21 CFR 11, GxP and VDA 6.4. Note: The versiondog data management system can be used together with SIMATIC PCS 7 V7 and V8. ■ Application versiondog can also be used for various functions beyond the limits of the SIMATIC PCS 7 process control system. This is because versiondog can manage all PC-based data and provides additional functionalities for a wide range of different data types - Adobe PDF, Microsoft Word and Excel as well as SIMATIC PCS 7, SIMATIC S5, SIMATIC S7, SIMATIC WinCC, SIMATIC WinCC flexible, ProTool or SINUMERIK 840D from Siemens or systems and applications from other vendors. The comprehensive range is being continuously expanded. 1/8 Siemens ST PCS 7 AO · 2013 Important functions of versiondog in the context of SIMATIC PCS 7: • Central data storage Server-based data storage with clear project structure, user and access management, protected against inadvertent overwriting • Version management with audit trail of versiondog: Version assignment and documentation with logging of all changes as proof of who, when, what and why; visualization of changes by means of comparative graphic display for CFC and SFC • Smart Compare Comparator modules for alignment of different project states with clear representation of differences • Automatic data saving Cyclic, automatic data saving of engineering stations, automation systems and operator stations • Verification of server version Cyclic, automatic comparison of versions between the programs on the productive systems and on the project server for the automation systems of the plant ■ More information AUVESY GmbH & Co KG Lazarettstraße 1 76829 Landau Germany Tel.: +49 6341 944 600 Fax: +49 6341 944 611 E-mail: [email protected] Additional information is available on the Internet at: www.versiondog.de © Siemens AG 2013 Advanced Process Control 2 2/2 INCA MPC: Model-predictive multi-variable controller 2/3 INCA Sensor: Soft sensors for non-measurable quality variables 2/5 INCA PID Tuner: Expert tool for the optimization of PID controllers 2/6 ADCO: Adaptive controller 2/7 FuzzyControl++: Configuration tool for fuzzy logic 2/9 NeuroSystems: Configuration tool for neural networks Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Advanced Process Control INCA MPC: Model-predictive multi-variable controller ■ Overview PCS 7 Add-on without MPC This procedure is also used by INCA MPC, a multi-variable controller of the latest generation. INCA MPC differs from classic MPC controllers due to a series of functional extensions. Modern modeling methods, bumpless switching between different models (multi-model handling), expansions for batch process optimization, non-linear predictions, and a high quality of control are setting new standards and enable the control of non-linear processes as well as plant-wide optimization. fit for SIMATIC PCS 7 V8 with MPC limitation Approach limitations closer with setpoints The INCA MPC software itself runs on a separate PC with Windows 2000, Windows XP, Windows Vista or Windows 7. ∆=Profit Note: INCA MPC can be used together with SIMATIC PCS 7 V7 and V8. ■ Application INCA MPC for the glass industry Preconfigured solutions based on INCA MPC are available specifically for the glass industry. G_PCS7_XX_00021 2 INCA MPC Multi-variable controller with integrated optimization procedure Common control concepts in the process industry today are still almost exclusively based on PID controllers and also include manual intervention by the plant operator. In processes with complex dynamics, linked process variables or limitations, PID controllers reach their limit. Additional weak spots are product or load changes which are generally carried out partly or completely by the plant operator. This causes variations which prevent optimum quality being maintained at all times. However, if a process is to be operated close to the capacity limit, while at the same time minimizing waste and assuring the required quality, consideration of these precise boundary conditions in the controller strategy is absolutely essential. By carefully applying advanced modern control procedures (Advanced Process Control, APC), the process industry has real leverage available for reducing costs and increasing quality. Advanced Process Control establishes process optimization as a link between the planning and scheduling functions of the execution level as well as the process control functions of the control level. Of all the modern control procedures, Model Predictive Control (MPC) has emerged as the most suitable approach in numerous applications. MPC simplifies the handling of complex plant dynamics, permits the early elimination of faults, takes into consideration the plant limitations, and allows complex process control strategies. 2/2 Siemens ST PCS 7 AO · 2013 The Glass@Max product series currently comprises: • Tubingline@Max for dimensioning control of glass tubes • Feeder@Max for temperature profile control in glass channels • Melter@Max for floor and atmosphere temperature control in glass melting ends Application examples of INCA MPC in the chemical industry • Ammonia, urea, nitric acid, granulates, and phosphoric acid plants - Increase in throughput, for example, by up to 2% for ammonia and up to 5% for urea - Increase in steam export by up to 1% (ammonia) - Reduction in specific energy consumption by up to 1% - Increased plant availability - Lower sensitivity to changes in condition of supplied gas (ammonia) • Distillation towers - Operation closer to the concentration restrictions - Reduction of steam consumption - Operation within a performance range of large bandwidth (from technical minimum up to full-load) • Batch plants (non-linear version of INCA MPC) - Proven reduction in response time (dead time) by up to 20% ■ More information IPCOS Tel.: +32 1639 3083 Fax: +32 1639 3080 E-mail: [email protected] Additional information is available on the Internet at: www.ipcos.com © Siemens AG 2013 Advanced Process Control INCA Sensor: Soft sensors for non-measurable quality variables ■ Overview PCS 7 Add-on fit for SIMATIC PCS 7 V8 The plant operator is usually responsible for complete or partial process control. Weak points in process control are also reflected by changes in product quality or in the utilization of production capacity. Since no quality values are known during a conversion, the production specifications do not correspond to the quality requirements over longer periods. These problems can be solved by using soft sensors. Soft sensors are calculation procedures which determine nonmeasurable quality variables on the basis of measurable process values (pressures, flow rates, temperatures, levels, etc.) in cycles of between 0.5 and 3 minutes. The calculation is made on the basis of a (non-)linear parametric model generated from historic plant data or through dedicated tests. The high-speed soft sensor predictions can be consolidated by laboratory analyses or values from online analyzers. The soft sensor predictions enable the frequency of laboratory analyses and the use of online analyzers to be reduced. They raise product quality while at the same time reducing operating costs. INCA Sensor is a tool for designing, parameterizing and operating soft sensors. It makes it easier to master complex plant dynamics, and enables operating conditions to be optimized so that the quality of the end product is assured. Online determination of quality variables Production plants in the process industry today rely on regular and extremely time-consuming laboratory analyses for quality control purposes (new measured values typically every 8 to 24 hours). Or they use very expensive and high-maintenance online analyzers (new values typically every 20 to 60 minutes). In order to raise productivity and run the process up to its full capacity while maintaining the required quality, it is necessary to measure product quality online with a refresh rate of between 0.5 and 3 minutes. This ensures that the controller responds at the right time and the product specifications are maintained. Process variables Temperatures Pressures Levels Flow rates (every 0.5 ... 3 min) Quality variables Densities Concentration Melt Indexes Viscosities (every 8 ... 24 hrs) from laboratory Note: INCA Sensor can be used together with SIMATIC PCS 7 V7 and V8. INCA Sensor soft sensors Non-linear parametric model Consolidation/ compensation and updating Quality variables Densities Concentration Melt-flow indices Viscosities (every 0.5 ... 3 min) from INCA Sensor To the closed-loop control system Siemens ST PCS 7 AO · 2013 2/3 2 © Siemens AG 2013 Advanced Process Control INCA Sensor: Soft sensors for non-measurable quality variables ■ Application 2 Application examples • Polymer thickness • Polymer melt-flow index • Viscosity • Product concentration at the outlet of reaction or distillation columns • Plant efficiency/utilization factor • Gas concentrations (NOx, CO2, etc.) INCA Sensor sets new standards for the permanent plant-wide optimization and control of non-linear processes. INCA Sensor differs from other soft-sensor program packages due to its series of function expansions that support the designer when drafting reliable soft sensors: • Modern modeling methods such as linear transmission functions, general non-linear models (GNOMOs) or estimates according to the partial least squares estimators method • Signal processing or pre-processing (offline and online) • Powerful tools for selecting suitable input variables • Input options for data from laboratories and analyzers Soft sensors are a prerequisite for plant optimization and quality control using advanced process control solutions such as INCA MPC. The INCA Sensor program package can run on standard PCs with Windows 2000, Windows XP, Windows Vista or Windows 7. It is linked to the SIMATIC PCS 7 process control system by means of OPC, where INCA Sensor is operated as an OPC client. 2/4 Siemens ST PCS 7 AO · 2013 ■ More information IPCOS Tel.: +32 1639 3083 Fax: +32 1639 3080 E-mail: [email protected] Additional information is available on the Internet at: www.ipcos.com © Siemens AG 2013 Advanced Process Control INCA PID Tuner: Expert tool for the optimization of PID controllers ■ Overview PCS 7 Add-on ■ Function fit for SIMATIC PCS 7 V8 The PCS 7 PID Tuner integrated in the CFC enables you to determine the optimum controller parameters in predefined steps for PID, PI and P controls in a control loop. The PCS 7 PID Tuner can be used for the software controllers CTRL_PID and CTRL_S. The INCA PID Tuner program package, on the other hand, is a controller-independent and manufacturerindependent tool for fast and user-friendly, computer-aided optimization of complex PID controllers. INCA PID Tuner can run on standard PCs with Windows 2000, Windows XP, Windows Vista or Windows 7. It is linked to the SIMATIC PCS 7 process control system by means of OPC. As an alternative to online data, files containing data collected earlier can also be evaluated offline. The program package is able to process the following file formats: • Microsoft Access • Microsoft Excel • MATLAB • INCATest • All types of ASCII files INCA PID Tuner contains predefined PID controller structures for PID controller types from SIMATIC PCS 7 and other manufacturers. With the aid of a dynamic process model, the user can determine the optimum controller setting step by step. Note: INCA PID Tuner can be used together with SIMATIC PCS 7 V7 and V8. ■ More information IPCOS Tel.: +32 1639 3083 Fax: +32 1639 3080 E-mail: [email protected] Additional information is available on the Internet at: www.ipcos.com 2 INCA PID Tuner differs from other controller optimization software through: • Optimization of PID control loops on the basis of engineering specifications • Controller setting for optimum compensation of disturbances • Controller setting for optimum command behavior with predefined setpoint changes Data acquisition Collection of process data by means of an online OPC connection to the SIMATIC PCS 7 operator system or from offline files. Many test signals are available for initiating the process, including: • Setpoint step-change • Manipulated variable step-change • Ramps • Pseudo-disturbance binary signals Data preprocessing The user can select and filter data to refine the results of the process identification. System identification A dynamic process model is defined on the basis of the collected process data. Various model structures can be used: with/without dead time and different system arrangements. Users have the option of influencing the system identification on the basis of their knowledge about the process. They can save and compare the resulting process models. Controller design On the basis of the chosen process model, controller parameters are determined for a certain specification. Consequently, the controller can be designed for optimum command behavior, optimum noise suppression or a combination of both. Simulation of the designed controller An evaluation of the control loop behavior is possible by simulation within INCA PID Tuner or online via the existing OPC connection. The simulation results obtained with different controller settings can be saved and compared. Good settings for primary control loops are a prerequisite for subsequent plant optimization, for example, using INCA MPC. Siemens ST PCS 7 AO · 2013 2/5 © Siemens AG 2013 Advanced Process Control ADCO: Adaptive controller ■ Overview 2 ■ Application PCS 7 Add-on fit for SIMATIC PCS 7 V8 0RGHO YDOXDWLRQ &RQWUROOHU V\QWKHVLV 3URFHVV LGHQWLILFDWLRQ Compared to the conventional PID controller, the adaptive controller ADCO is the better alternative, especially for processes that are difficult to control. This has the following advantages: • About 10 to 20% time savings in the commissioning phase due to the fast and rugged controller setting • Significantly better control quality for difficult processes • Very good adaptability, especially where there are changes to the process characteristics • Significant reductions in transmission times in the case of status transitions in batch processes (e.g. heating a product from temperature level A to level B) Note: 6HWSRLQW &RQWUROOHU &RQWUROOHU RXWSXW 3URFHVV The adaptive controller ADCO can be used together with SIMATIC PCS 7 V7 and V8. ■ Technical specifications $FWXDOYDOXH Conventional PID controllers are frequently used in manual mode in practice because the control quality achieved does not match the expectations. This is because either the controllers have been poorly set or because the processes are difficult to master using PID controllers, for example, temperature systems, processes with large dead times, or processes which change depending on time or operating point. In addition, setting PID controllers optimally requires specialized experience and is very time-consuming. A recommendable alternative for solving such problems is the adaptive controller ADCO. It works on the basis of a process model which is determined in the background during the adjustment process. Using this process model, ADCO can predict the result of a process intervention (predictive controller), for example,. how the opening of a steam valve by a certain amount will affect the process temperature. In the opposite direction, it is also able to determine the valve position required to achieve or retain a defined temperature value. ADCO with the process model has more process information available than conventional controllers, and uses this to improve the control quality. List of individual ADCO views ADCO is also available as a multi-range controller (ADMR). The special feature of this version is that is the control range can be divided into a maximum of 8 zones which can be individually optimized. Switching over between the zones can be carried out by the user or is event-dependent. 2/6 Siemens ST PCS 7 AO · 2013 ADCO Hardware requirements SIMATIC PCS 7 V5.x or higher with AS 41x automation systems Memory requirement 28 KB (once only) + 5 KB (per controller) Computing time Approx. 2 ms (S7-416) ■ More information i.p.a.s.-systeme An der Landwehr 6 60437 Frankfurt Germany Tel.: +49 69 950418-0 Fax: +49 69 950418-19 E-mail: [email protected] Additional information is available on the Internet at: www.ipas-systeme.de © Siemens AG 2013 Advanced Process Control FuzzyControl++: Configuration tool for fuzzy logic ■ Overview PCS 7 Add-on ■ Application fit for SIMATIC PCS 7 V8 Typical applications for fuzzy logic are: • Open-loop and closed-loop control • Parameter adaptation of controllers • Fault compensation and precontrol • Pattern recognition, process data evaluation and diagnosis • Automation of manual process interventions of a plant operator • Process control with coordination of subordinate open-loop and closed-loop controllers Examples include pressure, temperature and level controls, as well as control of speed and intervals. In early-warning and diagnostics units, fuzzy logic is used for the early detection of hazardous states and for the implementation of decision-making logic. ■ Function FuzzyControl++ supports users when creating a fuzzy system. The application of this tool requires only basic knowledge about such systems, as no mathematical or control settings have to be made. Users are supported during the configuration process by extensive online help. FuzzyControl++ is a Siemens configuration tool for fuzzy logic. It offers solutions for non-linear controllers and for predicting the behavior of complex mathematical procedures from process automation which are difficult or impossible to implement using standard tools. FuzzyControl++ enables fuzzy systems to be developed and configured effectively for the automation of technical processes. Empirical process knowledge and verbally described experience can be implemented as fuzzy rules directly in openloop and closed-loop controls, pattern recognition, decision logic, etc. FuzzyControl++ for SIMATIC PCS 7 comprises: • Configuration tool (runs with Windows XP, Windows 7 (32/64 bit) and Windows Server 2008 (32/64 bit)) • PCS 7 package (runtime software for SIMATIC PCS 7, consisting of function block for CFC and OS faceplates) The configuration tool is used to configure and generate the fuzzy systems. During operation, the runtime software then executes the systems which are present in a data block in the case of SIMATIC PCS 7. In order to solve optimization tasks by applying forecast models, FuzzyControl++ can also be combined with the adaptive SIMATIC PCS 7 Add-on NeuroSystems. Note: FuzzyControl++ can be used together with SIMATIC PCS 7 V7 and V8. Siemens ST PCS 7 AO · 2013 2/7 2 © Siemens AG 2013 Advanced Process Control FuzzyControl++: Configuration tool for fuzzy logic ■ Selection and ordering data 2 Order No. FuzzyControl++ for SIMATIC PCS 7 V7 (V7.1 or V7.0 SP1 and higher) and V8 FuzzyControl++ for SIMATIC PCS 7 2 languages (English, German), comprising: • Configuration tool, runs with Windows XP, Windows 7 (32/ 64 bit) and Windows Server 2008 (32/64 bit) • PCS 7 package with CFC runtime module and OS faceplates 2XV9 450-1WC10-0AA1 Engineering and runtime software, software class A Delivery package: Software on CD/DVD and license key 2/8 Siemens ST PCS 7 AO · 2013 ■ More information Siemens AG Industry Sector Industry Automation Division Industrial Automation Systems Industry Software Erlangen Tel.: +49 91 31 7-461 11 Fax: +49 91 31 7-447 57 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.com/it4industry © Siemens AG 2013 Advanced Process Control NeuroSystems: Configuration tool for neural networks ■ Overview PCS 7 Add-on ■ Benefits fit for SIMATIC PCS 7 V8 There are many good reasons for using NeuroSystems: 7 Artificial neural networks have now become the most frequently applied approach for black box modeling of technical, chemical and biological systems. 7 As a result of the complex non-linear response of neural networks, processes can be simulated without exact knowledge of the existing relationships and conditions. 7 The capability to learn and adapt, the fault tolerance, and the ability to process inexact or even contradictory information are particularly distinctive. 7 NeuroSystems is exceptionally well suited to prediction, optimization, classification, identification, and closed-loop control tasks and as a decision support system 7 Neural networks created using NeuroSystems can be integrated without problem into an automation environment by using runtime modules. 7 The neural networks execute completely in SIMATIC PCS 7. 7 Applications based on neural networks allow increases in performance, quality, productivity, and efficiency, and save personnel and time thanks to machine learning mechanisms. ■ Application During the automation of technical processes, especially their optimization, procedures and approaches with artificial intelligence are being increasingly used in addition to traditional methods. Neural networks are frequently applied in such cases, and these have already proven their performance capability in many applications. Notable successes can be achieved using them, even for tasks where conventional optimization procedures fail. Modeling of technical systems and processes using neural networks allows forecast models to be generated with which the process can be driven more target-oriented, uniformly, and with an increased quality. Significant increases in efficiency are possible using such prediction mechanisms. An advantage is that the simulation of a process requires no detailed knowledge of the prevailing conditions and relationships. Neural networks can also be used for classification tasks and pattern recognition, e.g. in order to identify specific plant statuses. In contrast to classic technical systems, a neural network consists of a complex interconnection of many simple processing units, so-called neurons. The architecture copies the structure of the biological nervous system. Neural networks are flexible and capable of learning. They can organize themselves, and work in a parallel structure. Systems which are capable of learning can be generated by combining neural networks with SIMATIC PCS 7 Add-on FuzzyControl++, and the strengths of the two procedures are combined. This opens up many new possibilities for automation technology. NeuroSystems enables the generation of artificial neural networks in process automation which cannot be produced using conventional means and methods, or only with great difficulty. NeuroSystems can be used to develop neural networks for complex optimization tasks, virtual soft sensors, predictions, identifications, classification tasks etc. simply and effectively even without special know-how. This results in blocks executable in SIMATIC PCS 7 which can be integrated into the automation structure by linking. Typical applications for neural networks include: • Complex closed-loop controls • Virtual soft sensors • Predictions • Identifications • Pattern recognition • Diagnostics and evaluation of process data The process industry - in particular the chemical industry - and the production industry are the main fields of application for neural networks. Quality control is one of the focal points for all sectors. ■ Function NeuroSystems supports users in the creation of neural networks. Configuration with NeuroSystems does not require any mathematical or control technology settings. Basic knowledge on such systems is sufficient. NeuroSystems includes functions for data analysis as well as for comprehensive test and validation tasks. When working with the system, configuration engineers have access to comprehensive online help. NeuroSystems for SIMATIC PCS 7 comprises: • Configuration tool (runs on the engineering station with Windows XP, Windows 7 (32/64 bit), Windows Server 2008 (32/64 bit)) • PCS 7 package (runtime software for SIMATIC PCS 7, consisting of function block for CFC and OS faceplates) The configuration tool is used to configure and generate the neural networks. During operation, the runtime software then executes the neural networks which are present in a data block in the case of SIMATIC PCS 7. Note: NeuroSystems can be used together with SIMATIC PCS 7 V7 and V8. Siemens ST PCS 7 AO · 2013 2/9 2 © Siemens AG 2013 Advanced Process Control NeuroSystems: Configuration tool for neural networks ■ Selection and ordering data 2 Order No. NeuroSystems for SIMATIC PCS 7 V7 (V7.1 or V7.0 SP1 and higher) and V8 NeuroSystems for SIMATIC PCS 7 2 languages (English, German), comprising: • Configuration tool for generating and testing neural networks with Windows XP, Windows 7 (32/64 bit), Windows Server 2008 (32/64 bit) • PCS 7 package with CFC runtime module and faceplates for one application 2XV9 450-1WC15-0AA0 Engineering and runtime software, software class A Delivery package: Software on CD/DVD and license key 2/10 Siemens ST PCS 7 AO · 2013 ■ More information Siemens AG Industry Sector Industry Automation Division Industrial Automation Systems Industry Software Erlangen Tel.: +49 91 31 7-461 11 Fax: +49 91 31 7-447 57 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.com/it4industry © Siemens AG 2013 Industry-specific applications 3 3/2 3/2 Cement industry CEMAT: Cement plant automation 3/6 3/6 Mining industry MINERALS AUTOMATION STANDARD 3/9 3/9 Telecontrol - SIPLUS RIC Telecontrol connection to control center in SIMATIC PCS 7 Telecontrol connection to third-party control center 3/18 3/21 3/21 Process Analytical Technology SIMATIC SIPAT: Optimization of product development and production Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Industry-specific applications Cement industry CEMAT: Cement plant automation ■ Overview ■ Function PCS 7 Add-on fit for SIMATIC PCS 7 V8 3 Drive faceplate with analog-value display, analog-value selection dialog, and curve display (from right to left) CEMAT is a process control system that was designed for the specific requirements of the cement industry and has proved successful over many years of use worldwide in the harsh environmental conditions of cement works. The current system platform for CEMAT is the SIMATIC PCS 7 process control system whose modern architecture offers the ideal basis for future-proof and economical solutions in the cement industry. CEMAT uses the basic functionality, the open system interfaces, the flexibility and the scalability of SIMATIC PCS 7 and optimizes the operating philosophy as well as the diagnostic, signaling and interlocking concept with industryspecific software packages for the special tasks in lime and cement works. This industry software was developed in close collaboration with cement manufacturers and is the product of over 35 years of experience in the cement industry. 3/2 Siemens ST PCS 7 AO · 2013 The functionality for the cement industry supplied in the form of the CEMAT software packages is integrated into the system structure of SIMATIC PCS 7 during the installation, and can be classified as follows: • Engineering components with function block libraries specially tailored to the cement industry • Automation components for open-loop/closed-loop control with communications components for the controller connection • HMI components with: - Redundancy and archiving functions - Library for all control system objects with information, diagnostic, and multimedia dialogs - Alarm system with industry-specific service functions - Diagnostic system for fast recognition of faults and reduction of downtimes - Additional functions such as signal tracking and signal status information - APL-style design • Web-compatible visualization of process displays and faceplates • Management information: listing and statistics functions as well as long-term archiving • Technological interfaces for linking technological add-on modules which are not part of the CEMAT product spectrum (also products from other manufacturers). © Siemens AG 2013 Industry-specific applications Cement industry CEMAT: Cement plant automation ■ Function (continued) Notes on delivery CEMAT can be supplied in two versions: • CEMAT V8.0 (current version; for new plants), can be used on system platform SIMATIC PCS 7 V8.0 including update 1 • CEMAT V7.1 (alternative, particularly for plant expansions), can be used on system platform SIMATIC PCS 7 V8.0 or SIMATIC PCS 7 V7.1 including service pack SIMATIC PCS 7 is not supplied with CEMAT, but must be ordered separately (see Catalog ST PCS 7). Message display with sector-specific information and message selection area It is especially worth noting the extensive multimedia support, e.g. by means of: • Video sequences for operating and service personnel • Showing of pictures in process screens • Integration of AutoCAD drawings (DXF format) • Integration of plant plans • Context-sensitive provision of information depending on place and time Object-based information area with I/O information Siemens ST PCS 7 AO · 2013 3/3 3 © Siemens AG 2013 Industry-specific applications Cement industry CEMAT: Cement plant automation ■ Selection and ordering data Order No. MINERALS AUTOMATION STANDARD/CEMAT V8.0 CEMAT engineering software 3 CEMAT OSENG V8.0 Engineering software, software class A, 2 languages (English, German), runs with Windows XP Professional 32-bit, Windows 7 Ultimate 32/64-bit, Windows Server 2003 R2 Standard 32-bit, or Windows Server 2008 R2 Standard 64-bit, single license for 1 installation 6DL5 436-8AX08-0XA0 CEMAT OS software for single station including AS runtime licenses (PLC) 6DL5 434-8AA08-0XA0 CEMAT OS PowerPack V8.0 for redundant pair of servers for expansion of the AS runtime licenses 6DL5 435-8AX08-0XA0 CEMAT OS software for redundant pair of servers including AS runtime licenses (PLC) 6DL5 433-8AA08-0XA0 Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license 6DL5 433-8AB08-0XA0 Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license 3/4 Software class A, 2 languages (English, German), runs with Windows Server 2003 R2 Standard 32-bit or Windows Server 2008 R2 Standard 64-bit, single license for 2 installations Type of delivery: 2 license key memory sticks, certificate of license • CEMAT PRSRT6 V8.0 for expansion from 3 to 6 AS • CEMAT PRSRT9 V8.0 for expansion from 6 to 9 AS • CEMAT PRSRTU V8.0 for expansion from 9 to unlimited AS Type of delivery: software and documentation on DVD, license key memory stick, certificate of license CEMAT RSRT6 V8.0 (6 AS) OS software Runtime for redundant pair of servers including runtime licenses for 6 AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003 R2 Standard 32-bit or Windows Server 2008 R2 Standard 64-bit, single license for 2 installations 6DL5 433-8AD08-0XA0 CEMAT OS PowerPacks for redundant pair of servers CEMAT OS software for client CEMAT RSRT3 V8.0 (3 AS) OS software Runtime for redundant pair of servers including runtime licenses for 3 AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003 R2 Standard 32-bit or Windows Server 2008 R2 Standard 64-bit, single license for 2 installations CEMAT RSRTU V8.0 (unlimited AS) OS software Runtime for redundant pair of servers including runtime licenses for unlimited AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003 R2 Standard 32-bit or Windows Server 2008 R2 Standard 64-bit, single license for 2 installations Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license Type of delivery: software and documentation on DVD, license key memory stick, certificate of license CEMAT MC V8.0 OS software Client Runtime, software class A, 2 languages (English, German), runs with Windows XP Professional 32-bit, Windows 7 Ultimate 32/64-bit, single license for 1 installation 6DL5 433-8AC08-0XA0 Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license Type of delivery: software and documentation on DVD, license key memory stick, certificate of license CEMAT OSRT3 V8.0 (3 AS) OS software Single Station Runtime including 3 runtime licenses for AS (PLC), software class A, 2 languages (English, German), runs with Windows XP Professional 32-bit, Windows 7 Ultimate 32/64-bit, Windows Server 2003 R2 Standard 32-bit, or Windows Server 2008 R2 Standard 64-bit, single license for 1 installation Order No. CEMAT RSRT9 V8.0 (9 AS) OS software Runtime for redundant pair of servers including runtime licenses for 9 AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003 R2 Standard 32-bit or Windows Server 2008 R2 Standard 64-bit, single license for 2 installations Siemens ST PCS 7 AO · 2013 CEMAT Software Upgrade V8.0 For upgrading existing CEMAT installations V6.1 and higher Engineering and runtime software, software class A, 2 languages (English, German), runs with Windows XP Professional 32-bit, Windows 7 Ultimate 32/64-bit, Windows Server 2003 R2 Standard 32-bit, or Windows Server 2008 R2 Standard 64-bit, single license for 1 installation Type of delivery: software and documentation on DVD, license key memory stick for WinCC User Archive Upgrade, certificate of license Can only be used together with a valid CEMAT license. 6DL5 433-8AB08-0XD0 6DL5 433-8AC08-0XD0 6DL5 433-8AD08-0XD0 6DL5 430-8AX08-0XE0 © Siemens AG 2013 Industry-specific applications Cement industry CEMAT: Cement plant automation ■ Ordering data Order No. CEMAT V7.1 CEMAT engineering software CEMAT OSENG V7.1 Engineering software, software class A, 2 languages (English, German), runs with Windows Server 2003/XP Professional, single license for 1 installation 6DL5 436-8AX17-0XA0 Order No. CEMAT RSRTU V7.1 (unlimited AS) OS software Runtime for redundant pair of servers including runtime licenses for unlimited AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003, single license for 2 installations Type of delivery: software and documentation on DVD, license key memory stick, certificate of license Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license CEMAT OS software for single station including AS runtime licenses (PLC) CEMAT OS PowerPacks for redundant pair of servers CEMAT OSRT3 V7.1 (3 AS) OS software Single Station Runtime including 3 runtime licenses for AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003/ XP Professional, single license for 1 installation 6DL5 434-8AA17-0XA0 CEMAT OS software for client 6DL5 435-8AX17-0XA0 Type of delivery: software and documentation on DVD, license key memory stick, certificate of license CEMAT OS software for redundant pair of servers including AS runtime licenses (PLC) CEMAT RSRT3 V7.1 (3 AS) OS software Runtime for redundant pair of servers including runtime licenses for 3 AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003, single license for 2 installations 6DL5 433-8AA17-0XA0 6DL5 433-8AB17-0XA0 Type of delivery: 2 license key memory sticks, certificate of license • CEMAT PRSRT6 V7.1 for expansion from 3 to 6 AS • CEMAT PRSRT9 V7.1 for expansion from 6 to 9 AS • CEMAT PRSRTU V7.1 for expansion from 9 to unlimited AS CEMAT Software Upgrade V7.1 for upgrading existing CEMAT installations V6.1 and higher Engineering and runtime software, software class A, 2 languages (English, German), runs with Windows XP Professional/Server 2003, single license for 1 installation Type of delivery: software and documentation on DVD, license key memory stick for WinCC User Archive Upgrade, certificate of license Can only be used together with a valid CEMAT license. 6DL5 433-8AB17-0XD0 6DL5 433-8AC17-0XD0 6DL5 433-8AD17-0XD0 6DL5 430-8AX17-0XE0 Siemens AG Industry Sector Industry Automation Industrial Automation Systems Erlangen Fax: +49 9131 18-3444 E-mail: [email protected] Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license CEMAT RSRT9 V7.1 (9 AS) OS software Runtime for redundant pair of servers including runtime licenses for 9 AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003, single license for 2 installations CEMAT OS PowerPack V7.1 for redundant pair of servers for expansion of the AS runtime licenses ■ More information Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license CEMAT RSRT6 V7.1 (6 AS) OS software Runtime for redundant pair of servers including runtime licenses for 6 AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003, single license for 2 installations 3 Software class A, 2 languages (English, German), runs with Windows Server 2003, single license for 2 installations Type of delivery: software and documentation on DVD, license key memory stick, certificate of license CEMAT MC V7.1 OS software Client Runtime, software class A, 2 languages (English, German), runs with Windows XP Professional, single license for 1 installation 6DL5 433-8AD17-0XA0 Additional information is available on the Internet at: www.siemens.com/cemat 6DL5 433-8AC17-0XA0 Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license Siemens ST PCS 7 AO · 2013 3/5 © Siemens AG 2013 Industry-specific applications Mining industry MINERALS AUTOMATION STANDARD ■ Overview ■ Function PCS 7 Add-on fit for SIMATIC PCS 7 V8 3 Drive faceplate The MINERALS AUTOMATION STANDARD is a process control system based on CEMAT and designed with the specific requirements of the mining industry in mind. It combines cement plant automation functions, developed over more than 35 years, with the automation functions typically required for mining applications. Like CEMAT, the MINERALS AUTOMATION STANDARD also uses the modern SIMATIC PCS 7 process control system, with its open and flexibly scalable architecture, as its system platform. This means that it also benefits from the innovative Advanced Process Library (APL), which takes the experience gained by configuration engineers and plant operators over many years and transforms it into an excellent range of basic functions that have an attractive design and are extremely easy to use. Building on this, the MINERALS AUTOMATION STANDARD optimizes both the operating philosophy as well as the diagnostics, signaling, and interlocking concept by using industry-specific software packages for the specific tasks that take place in the mining industry. 3/6 Siemens ST PCS 7 AO · 2013 The functionality for the mining industry supplied in the form of the MINERALS AUTOMATION STANDARD software packages is integrated into the system structure of SIMATIC PCS 7 during the installation, and can be classified as follows: • Engineering components with function block libraries specifically tailored to the mining industry • Automation components for open-loop/closed-loop control with communications components for the controller connection • HMI components with: - Redundancy and archiving functions - Library for all control system objects with information, diagnostic, and multimedia dialogs - Alarm system with industry-specific service functions - Diagnostic system for fast recognition of faults and reduction of downtimes - Additional functions such as signal tracking and signal status information - APL-style design • Web-compatible visualization of process displays and faceplates • Management information: listing and statistics functions as well as long-term archiving • Technological interfaces for linking technological add-on modules which are not part of the MINERALS AUTOMATION STANDARD product spectrum (as well as products from other manufacturers) © Siemens AG 2013 Industry-specific applications Mining industry MINERALS AUTOMATION STANDARD ■ Function (continued) 3 Message display with sector-specific information and message selection area It is especially worth noting the extensive multimedia support, e.g. by means of: • Video sequences for operating and service personnel • Showing of pictures in process screens • Integration of AutoCAD drawings (DXF format) • Integration of plant plans • Context-sensitive provision of information depending on place and time ■ Selection and ordering data MINERALS AUTOMATION STANDARD is currently available as Version 8.0. MINERALS AUTOMATION STANDARD V8.0 can be used on system platform SIMATIC PCS 7 V8.0 incl. update 1. SIMATIC PCS 7 is not included in the CEMAT scope of delivery and instead must be ordered separately where required (see Catalog ST PCS 7). Order No. CEMAT OS software for single station including AS runtime licenses (PLC) CEMAT engineering software Type of delivery: software and documentation on DVD, license key memory stick, certificate of license Notes on delivery Order No. MINERALS AUTOMATION STANDARD V8.0 CEMAT OSENG V8.0 Engineering software, software class A, 2 languages (English, German), runs with Windows XP Professional 32-bit, Windows 7 Ultimate 32/64-bit, Windows Server 2003 R2 Standard 32-bit, or Windows Server 2008 R2 Standard 64-bit, single license for 1 installation Object-based information area with I/O information 6DL5 436-8AX08-0XA0 CEMAT OSRT3 V8.0 (3 AS) OS software Single Station Runtime including 3 runtime licenses for AS (PLC), software class A, 2 languages (English, German), runs with Windows XP Professional 32-bit, Windows 7 Ultimate 32/64-bit, Windows Server 2003 R2 Standard 32bit, or Windows Server 2008 R2 Standard 64-bit, single license for 1 installation 6DL5 434-8AA08-0XA0 Type of delivery: software and documentation on DVD, license key memory stick, certificate of license CEMAT OS software for client CEMAT MC V8.0 OS software Client Runtime, software class A, 2 languages (English, German), runs with Windows XP Professional 32-bit, Windows 7 Ultimate 32/64-bit, single license for 1 installation 6DL5 435-8AX08-0XA0 Type of delivery: software and documentation on DVD, license key memory stick, certificate of license Siemens ST PCS 7 AO · 2013 3/7 © Siemens AG 2013 Industry-specific applications Mining industry MINERALS AUTOMATION STANDARD ■ Ordering data Order No. CEMAT OS software for redundant pair of servers including AS runtime licenses (PLC) 3 CEMAT RSRT3 V8.0 (3 AS) OS software Runtime for redundant pair of servers including runtime licenses for 3 AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003 R2 Standard 32-bit or Windows Server 2008 R2 Standard 64-bit, single license for 2 installations 6DL5 433-8AA08-0XA0 6DL5 433-8AB08-0XA0 Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license CEMAT RSRT9 V8.0 (9 AS) OS software Runtime for redundant pair of servers including runtime licenses for 9 AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003 R2 Standard 32-bit or Windows Server 2008 R2 Standard 64-bit, single license for 2 installations 6DL5 433-8AC08-0XA0 Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license CEMAT RSRTU V8.0 (unlimited AS) OS software Runtime for redundant pair of servers including runtime licenses for unlimited AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003 R2 Standard 32-bit or Windows Server 2008 R2 Standard 64-bit, single license for 2 installations 6DL5 433-8AD08-0XA0 Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license ■ More information Siemens AG Industry Sector Industry Automation Industrial Automation Systems Erlangen Fax: +49 9131 18-3444 E-mail: [email protected] 3/8 CEMAT OS PowerPack V8.0 for redundant pair of servers for expansion of the AS runtime licenses Software class A, 2 languages (English, German), runs with Windows Server 2003 R2 Standard 32-bit or Windows Server 2008 R2 Standard 64-bit, single license for 2 installations Type of delivery: software and documentation on DVD, 2 license key memory sticks, certificate of license CEMAT RSRT6 V8.0 (6 AS) OS software Runtime for redundant pair of servers including runtime licenses for 6 AS (PLC), software class A, 2 languages (English, German), runs with Windows Server 2003 R2 Standard 32-bit or Windows Server 2008 R2 Standard 64-bit, single license for 2 installations Order No. CEMAT OS PowerPacks for redundant pair of servers Siemens ST PCS 7 AO · 2013 Type of delivery: 2 license key memory sticks, certificate of license • CEMAT PRSRT6 V8.0 for expansion from 3 to 6 AS • CEMAT PRSRT9 V8.0 for expansion from 6 to 9 AS • CEMAT PRSRTU V8.0 for expansion from 9 to unlimited AS 6DL5 433-8AB08-0XD0 6DL5 433-8AC08-0XD0 6DL5 433-8AD08-0XD0 © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to control center in SIMATIC PCS 7 ■ Overview PCS 7 Add-on fit for SIMATIC PCS 7 V8 Control center 3 SINAUT MD741-1 IEC 60870-5-104 DSL router SCALANCE S612, security module Converter TCP/IP ↔ serial Radio network IEC 60870-5-101 SIPLUS RIC Bundle with SIMATIC S7-400 SCALANCE X101-1LD SINAUT MD2 SIPLUS RIC Bundle with SIMATIC S7-300 Fiber-optic cable IEC 60870-5-101 SIPROTEC 7SJ63 SCALANCE X101-1LD SINAUT MD741-1 SINAUT MD2 SINAUT MD2 SINAUT MD741-1 SIPLUS RIC Bundle with SIMATIC S7-300 SIPLUS RIC Bundle with SIMATIC ET 200S SIPLUS RIC Bundle with SIMATIC S7-400H SIPLUS RIC Bundle with SIMATIC ET 200S SIPLUS RIC Bundle with SIMATIC S7-300 G_PCS7_XX_00217 IEC 60870-5-103 Flexible communication options with SIPLUS RIC in a wide area network (WAN) The telecontrol communication between a telecontrol center integrated in SIMATIC PCS 7 and its outstations (Remote Terminal Units) is based on SIPLUS RIC bundles and is possible via serial communication links and also over Ethernet TCP/IP communication links – optionally with the telecontrol protocols • IEC 60870-5-104 (Ethernet TCP/IP) • IEC 60870-5-101 (serial) • Modbus RTU (Ethernet TCP/IP or serial) Note: Telecontrol integration into the SIMATIC PCS 7 process control system using SIPLUS RIC bundles with IEC 60870-5-104, IEC 60870-5-101 or Modbus RTU protocol requires one of the following software combinations: • SIMATIC PCS 7 V8.0 (incl. Update 1) and SIMATIC PCS 7 TeleControl V8.0 • SIMATIC PCS 7 V7.1 and SIMATIC PCS 7 TeleControl V7.1 The telecontrol center integrated with SIMATIC PCS 7 TeleControl into the operator system of the process control system is the master during telecontrol communication. The Remote Terminal Units (RTUs) are slaves of the control center on the one hand, but can additionally be masters for subordinate outstations (IEC 60870-5-101/-104/-103 slaves). Siemens ST PCS 7 AO · 2013 3/9 © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to control center in SIMATIC PCS 7 ■ Design IEC 60870-5-101/IEC 60870-5-104 telecontrol protocol Further hardware and software components from Catalog IK PI supplement the SIPLUS RIC product range for configuration of IEC 60870-5-101/104 telecontrol applications, e.g.: • TCP/IP converters – serial and MD modem modules • Mobile radio components • Industrial Ethernet switches, TCP/IP routers, and media converters • SCALANCE W Industrial Wireless LAN components • SCALANCE S612 and S613 industrial security modules • Dedicated line accessories • Cables The following types of RTU are suitable as outstations in telecontrol applications with the IEC 60870-5-101 (serial) or IEC 60870-5-104 (Ethernet TCP/IP) telecontrol protocol: Number of I/Os Number of (dependent on CPU size, pro- information/ tocol type, and application) data points integrated in SIMATIC ET 200S 30 … 200 I/Os Approx. 200 SIMATIC S7-300/S7-300F 100 … 2 000 I/Os Approx. 2 000 SIMATIC S7-400/S7-400F 500 … 5 000 I/Os Approx. 5 000 SIMATIC S7-400H/ S7-400FH 500 … 5 000 I/Os Approx. 5 000 Network topologies In order to configure complete, hierarchical telecontrol networks, it is possible to configure basic topology forms such as point-topoint, multipoint, star and ring in various media versions and to combine them depending on the infrastructure requirements. Third-party RTUs The SIPLUS RIC product range comprises individual libraries for telecontrol protocols as well as cost-effective SIPLUS RIC bundles in which the SIMATIC controller and the telecontrol protocol for an RTU are combined together. Further information can be found in the section "SIPLUS RIC bundles". Examples of media versions • Private networks - Wireless - Dedicated line via fiber-optic cable or modem, e.g. SINAUT MD2 - Ethernet network, e.g. with SCALANCE X and fiber-optic cables - WLAN, e.g. with SCALANCE W • Public networks - GPRS - EGPRS - UMTS - DSL - Satellite communication, e.g. Inmarsat Advantages of the TCP/IP-based connection through IEC 60870-5-104 are simultaneous data transfer to several devices and diagnostics using SIMATIC Manager. Security mechanisms are not defined in the application area of IEC 60870-5-104. Therefore encryption of the user data (data integrity) and authentication of the communication partners must be implemented separately (Industrial Security). Control center SIMATIC PCS 7 TeleControl Ethernet SCALANCE S613 IEC 60870-5-104 MD741 Internet RTU ET 200S with IM 151-8 PN/DP CPU DSL router GPRS radio network RTU S7-300 with CP 343 Complex network structure, combination of different topologies and media MD741 Third-Party RTU RTU S7-400 with CP 443 IEC 60870-5-104 Example of complex TCP/IP-based WAN with cable and GPRS networks 3/10 IEC 60870-5-104 RTU ET 200S with IM 151-8 PN/DP CPU Siemens ST PCS 7 AO · 2013 RTU S7-300 with CP 343 IEC 60870-5-104 G_PCS7_XX_00271 3 Controller © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to control center in SIMATIC PCS 7 ■ Design (continued) Redundancy Modbus RTU telecontrol protocol The availability of the telecontrol communication can be improved by connecting the RTU over two paths to the control center in the process control system. The two redundant transmission paths can be based on the same or different communication protocols. The following types of RTU are suitable as outstations in telecontrol applications with the Modbus RTU telecontrol protocol (serial or Ethernet TCP/IP): The use of redundant RTUs of type S7-400H (fault-tolerant) or S7-400FH (safety-related and fault-tolerant) results in further possibilities for increasing the availability, e.g. the redundant design of telecontrol communication, fieldbus and process I/O. As a result of the seamless integration of the telecontrol system in the SIMATIC PCS 7 process control system, its implementation depends on the redundancy concept of the complete system (see example of redundant telecontrol configuration with the IEC 60870-5-101/104 telecontrol protocols). SIMATIC PCS 7 OS clients Control center SIMATIC PCS 7 TeleControl OS with redundant servers Terminal bus Redundant system bus TCP/IP to serial converter IEC 60870-5-101 redundant TCP/IP WAN router IEC 60870-5-104 redundant G_PCS7_XX_00274 RTU S7-400H with CP 443 ET 200M redundant Number of I/Os (dependent on CPU size, protocol type, and application) integrated in SIMATIC ET 200S 30 … 200 I/Os SIMATIC S7-300/S7-300F 100 … 2 000 I/Os SIMATIC S7-400/S7-400F 500 … 5 000 I/Os Third-party RTUs The SIPLUS RIC product range comprises individual libraries for telecontrol protocols as well as cost-effective SIPLUS RIC bundles in which the SIMATIC controller and the telecontrol protocol for an RTU are combined together. Further information can be found in the section "SIPLUS RIC bundles". Further hardware and software components from Catalog IK PI supplement the SIPLUS RIC product range for configuration of Modbus telecontrol applications, e.g.: • TCP/IP converters – serial and MD modem modules • Mobile radio components • Industrial Ethernet switches, TCP/IP routers, and media converters • SCALANCE W Industrial Wireless LAN components • Dedicated line accessories • Cables Network topologies RTU S7-400H ET 200M redundant with 2 x CP 341 Controller Example of redundant telecontrol configuration with the IEC 60870-5-101/104 telecontrol protocols The Modbus RTU telecontrol protocol can be used to implement telecontrol networks based on point-to-point and multi-point topologies, both serial and Ethernet TCP/IP. Various media versions can be used for private and public networks, e.g.: • Private networks: - Wireless - Dedicated line via fiber-optic cable or modem, e.g. SINAUT MD2 - Ethernet network, e.g. with SCALANCE X and fiber-optic cables - WLAN, e.g. with SCALANCE W • Public networks: - GPRS - EGPRS - UMTS - DSL Interfacing of SIPROTEC protective equipment The additional registration SIPLUS RIC IEC 60870-5-103 Master for SIPLUS RIC bundles also allows interfacing of SIPROTEC protective equipment via SIMATIC PCS 7 TeleControl. The RTU (S7-400/S7-300/ET 200S with CPU) then serves as a converter between the IEC 60870-5-103 protection data protocol and the IEC 60870-5-101 or IEC 60870-5-104 protocol. Compared to PROFIBUS DP interfacing of the protective equipment, this configuration provides the following advantages: • Greater distances are possible • The highly exact time stamps are transferred from the protective equipment to the control system. Siemens ST PCS 7 AO · 2013 3/11 3 © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to control center in SIMATIC PCS 7 ■ Design (continued) Control center Modbus master 3 TCP/IP WAN router SCALANCE X101-1LD TCP/IP to serial converter SINAUT MD2 Fiber-optic cable SIMATIC S7-400 with CP 443 and software library (Modbus slave) SINAUT MD2 SIPLUS RIC bundle with SIMATIC ET 200S (Modbus slave) SINAUT MD2 Point-topoint Multi-point G_PCS7_XX_00273 SCALANCE X101-1LD SIPLUS RIC bundle with SIMATIC S7-300 (Modbus slave) Example of telecontrol configuration with the Modbus RTU telecontrol protocol (Ethernet TCP/IP and serial) To permit redundant data transmission, RTUs can be connected to the control center in the SIMATIC PCS 7 process control system over two paths. Two operating modes are available: • Load sharing: parallel utilization of both paths • Master/standby: only one path is active, the other is passive The performance of the uniform telecontrol technology can be scaled as follows with the SIPLUS RIC bundles: Performance SIPLUS RIC bundles Components of a SIMATIC controller type (S7-300, S7-400 etc.) are combined with the library for a telecontrol protocol in SIPLUS RIC RTU bundles. In the version "SIPLUS RIC Extreme", they are also suitable for operation under exceptional conditions, e.g., ambient temperatures from -25 to +70 °C, condensation or extraordinary medial loads. SIPLUS RIC Bundle with SIMATIC S7-400/400F SIPLUS RIC Bundle with SIMATIC S7-300/300F SIPLUS RIC Bundle with SIMATIC ET 200S Data volume 3/12 Siemens ST PCS 7 AO · 2013 G_PCS7_XX_00216 The SIPLUS RIC bundles configured as "Slave" for the telecontrol interface usually consist of: • CPU • Interface/communication module • Memory card • CD with library and registration code SIPLUS RIC Bundle with SIMATIC S7-400H/400FH © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to control center in SIMATIC PCS 7 ■ Design (continued) Decision criteria for the data volume to be processed and the maximum buffer size Bundles SIPLUS RIC ET 200S bundle SIPLUS RIC S7-300 bundle CPU IM 151-7 IM 151-8 IM 151-7F IM 151-8F CPU 314C-2 CPU 315-2 PN/DP PN/DP SIPLUS RIC S7-400 bundle CPU 317-2 PN/DP CPU 319-2 PN/DP CPU 412-1 CPU 315F-2 CPU 317F-2 CPU 319F-2 PN/DP PN/DP PN/DP Working memory 128/192 KB 192/256 KB 192 KB Unbuffered 64/128 KB (non-retain) CPU 412-2 PN CPU 414-3 PN/DP CPU 416-3 PN/DP CPU 417-5H PN/DP CPU 412-5H CPU 414-5H CPU 416-5H PN/DP PN/DP PN/DP 384/512 KB 1024/1536 KB 2048/2560 KB 288 KB 1 MB 4 MB 16 MB 32 MB 128/192 KB 128 KB 256/384 KB 768/1280 KB 1348/1860 KB - - - - - Buffered 64 KB 64 KB 64 KB 128 KB 256 KB 700 KB - - - - - Code - - - - - - 144 KB 512 KB 2 MB 8/6 MB 16 MB Data - - - - - - 144 KB 512 KB 2 MB 8/10 MB 16 MB SIPLUS RIC 64 KB1) program 64 KB1) 64 KB1) 64 KB1) 64 KB1) 64 KB1) 64 KB1) 64 KB1) 64 KB1) 64 KB1) 64 KB1) SIPLUS RIC 64 KB2) buffer 64 KB2) 64 KB2) 192 KB 2) 704 KB2) 1024 KB2) 96 KB2) 0.25 MB2) 1 MB2) 1 MB2) 1 MB2) Loading by 90 % SIPLUS RIC 90 % 90 % 66 % 50 % 25 % 70 % 50 % 50 % 25 % 12 % TCP/IP con- nections 8 8 8 16 32 30 via CP 443 46 62 94 118 Recommen- 200 ded number of information/ data points 200 200 1 000 2 000 5 000 500 1 000 2 000 5 000 5 000 1) The memory requirements increase due to the amount of information. 2) Free storage space is reduced due to the amount of information. ■ Function Telecontrol communication with SIPLUS RIC is characterized by the following features: • Uniform configuration using the SIMATIC Manager • Event-driven data transfer • Monitored output of commands for reliable detection of malfunctions • Diagnostics functions for rapid tracing and elimination of faults • High availability thanks to redundant data communication Additional special features of the IEC 60870-5-101 and IEC 60870-5-104 telecontrol protocols include: • Time stamping for data acquisition in the outstation • Data buffering for bridging communication breaks: - RTU of type SIMATIC ET 200S: Approx. 800 message frames - RTU of type SIMATIC S7-300 and S7-300F: Up to 25 000 message frames - RTU of type SIMATIC S7-400, S7-400F, S7-400H, and S7-400FH: Up to 25 000 message frames • Time synchronization via the control center Siemens ST PCS 7 AO · 2013 3/13 3 © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to control center in SIMATIC PCS 7 ■ Selection and ordering data Order No. Order No. SIPLUS RIC IEC 60870-5-101/-104 bundles for the telecontrol connection to control center in SIMATIC PCS 7 3 Bundles with SIMATIC ET 200S (CPU integrated); up to approx. 200 information/data points Extreme bundles with IEC 60870-5-104 telecontrol protocol (TCP/IP) Runtime software and electronic documentation, 2 languages (English, German), software class A, single license for 1 installation SIPLUS RIC ET 200S Extreme bundle T104 MA/SL IM151-8 PN/DP MMC 128 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIPLUS IM 151-8 PN/ DP CPU including 128 KB Micro Memory Card 6AG6 003-6BB01-0BA7 SIPLUS RIC ET 200S Extreme bundle T104 MA/SL IM151-8 PN/DP MMC 512 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIPLUS IM 151-8 PN/ DP CPU including 512 KB Micro Memory Card 6AG6 003-6BB01-0CA7 Standard bundles with IEC 60870-5-101 telecontrol protocol (serial) SIPLUS RIC ET 200S bundle T101 MA/SL IM151-7 CP1 MMC 128 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC IM 151-7 CPU incl. 128 KB Micro Memory Card, 1SI module with RS 232/RS 485 interface 6AG6 003-5BA00-1BA0 SIPLUS RIC ET 200S bundle T101 MA/SL IM151-8 CP1 MMC 128 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC IM 151-8 PN/DP CPU including 128 KB Micro Memory Card, 1SI module with RS 232/RS 485 interface 6AG6 003-5BA01-1BA0 Runtime software and electronic documentation, 2 languages (English, German), software class A, single license for 1 installation Standard bundles with IEC 60870-5-101 telecontrol protocol (serial) Extreme bundles with IEC 60870-5-101 telecontrol protocol (serial) SIPLUS RIC ET 200S Extreme bundle T101 MA/SL IM151-7 CP1 MMC 128 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIPLUS IM 151-7 CPU incl. 128 KB Micro Memory Card, SIPLUS 1SI module with RS 232/ RS 485 interface 6AG6 003-6BA00-1BA7 SIPLUS RIC ET 200S Extreme bundle T101 MA/SL IM151-8 CP1 MMC 128 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIPLUS IM 151-8 PN/DP CPU including 128 KB Micro Memory Card, SIPLUS 1SI module with RS 232/RS 485 interface 6AG6 003-6BA01-1BA7 Standard bundles with IEC 60870-5-104 telecontrol protocol (TCP/IP) SIPLUS RIC ET 200S bundle T104 MA/SL IM151-8 PN/DP MMC 128 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC IM 151-8 PN/DP CPU including 128 KB Micro Memory Card 6AG6 003-5BB01-0BA0 SIPLUS RIC ET 200S bundle T104 MA/SL IM151-8 PN/DP MMC 512 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC IM 151-8 PN/DP CPU including 512 KB Micro Memory Card 6AG6 003-5BB01-0CA0 SIPLUS RIC ET 200S bundle T104 MA/SL IM151-8F PN/DP MMC 512 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC IM 151-8F PN/DP CPU including 512 KB Micro Memory Card 6AG6 003-5BB11-0BA0 3/14 Bundles with SIMATIC S7-300/ S7-300F controller; up to approx. 2 000 information/data points Siemens ST PCS 7 AO · 2013 SIPLUS RIC S7-300 bundle T101MA/ SL CPU314 CP340 MMC 128 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC S7-CPU 314 including 128 KB Micro Memory Card, CP 340 with RS 232 interface 6AG6 003-1BA01-1BA0 SIPLUS RIC S7-300 bundle T101 MA/SL CPU314 CP341 MMC 128 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC S7-CPU 314 including 128 KB Micro Memory Card, CP 341 with RS 232 interface 6AG6 003-1BA01-4BA0 SIPLUS RIC S7-300 bundle T101 MA/SL CPU314C-2 PN/DP MMC 512 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC S7-CPU 314C-2 PN/DP including 512 KB Micro Memory Card, CP 341 with RS 232 interface 6AG6 003-1BA07-4CA0 SIPLUS RIC S7-300 bundle T101 MA/SL CPU315 CP341 MMC 512 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC S7-CPU 315-2 DP including 512 KB Micro Memory Card, CP 341 with RS 232 interface 6AG6 003-1BA02-4CA0 SIPLUS RIC S7-300 bundle T101 MA/SL CPU315-2 PN/DP MMC 512 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC S7-CPU 315-2 PN/DP including 512 KB Micro Memory Card, CP 341 with RS 232 interface 6AG6 003-1BA03-4CA0 SIPLUS RIC S7-300 bundle T101 MA/SL CPU315F-2 DP CP341 MMC 512 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC S7-CPU 315F-2 DP including 512 KB Micro Memory Card, CP 341 with RS 232 interface 6AG6 003-1BA10-4CA0 © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to control center in SIMATIC PCS 7 ■ Bestelldaten Order No. SIPLUS RIC S7-300 bundle T101 MA/SL CPU317-2 PN/DP MMC 2 MB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC S7-CPU 317-2 PN/DP including 2 MB Micro Memory Card, CP 341 with RS 232 interface 6AG6 003-1BA05-4DA0 SIPLUS RIC S7-300 bundle T101 MA/SL CPU319-3 PN/DP MMC 2 MB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC S7-CPU 319-3 PN/DP including 2 MB Micro Memory Card, CP 341 with RS 232 interface 6AG6 003-1BA06-4DA0 Extreme bundles with IEC 60870-5-101 telecontrol protocol (serial) SIPLUS RIC S7-300 Extreme bundle T101 MA/SL CPU314 CP340 MMC 128 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIPLUS S7-CPU 314 including 128 KB Micro Memory Card, SIPLUS CP 340 with RS 232 interface 6AG6 003-2BA01-1BA7 SIPLUS RIC S7-300 Extreme bundle T101 MA/SL CPU315 CP341 MMC 512 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIPLUS S7-CPU 315-2 DP including 512 KB Micro Memory Card, SIPLUS CP 341 with RS 232 interface 6AG6 003-2BA02-4CA7 SIPLUS RIC S7-300 Extreme bundle T101 MA/SL CPU317-2 PN/DP CP341 MMC 2 MB SIPLUS RIC IEC 60870-5-101 master/slave with SIPLUS S7-CPU 317-2 PN/DP including 2 MB Micro Memory Card, SIPLUS CP 341 with RS 232 interface 6AG6 003-2BA05-4DA7 Order No. SIPLUS RIC S7-300 bundle T104 MA/SL CPU315-2 PN/DP MMC 512 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 315-2 PN/DP including 512 KB Micro Memory Card 6AG6 003-1BB03-0CA0 SIPLUS RIC S7-300 bundle T104 MA/SL CPU315-2 PN/DP MMC 2 MB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 315-2 PN/DP including 2 MB Micro Memory Card 6AG6 003-1BB03-0DA0 SIPLUS RIC S7-300 bundle T104 MA/SL CPU315F-2 PN/DP MMC 512 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 315F-2 PN/DP including 512 KB Micro Memory Card 6AG6 003-1BB11-0CA0 SIPLUS RIC S7-300 bundle T104 MA/SL CPU317-2 PN/DP MMC 2 MB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 317-2 PN/DP including 2 MB Micro Memory Card 6AG6 003-1BB05-0DA0 SIPLUS RIC S7-300 bundle T104 MA/SL CPU317F-2 PN/DP MMC 2 MB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 317F-2 PN/DP including 2 MB Micro Memory Card 6AG6 003-1BB13-0DA0 SIPLUS RIC S7-300 bundle T104 MA/SL CPU319-3 PN/DP MMC 2 MB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 319-3 PN/DP including 2 MB Micro Memory Card 6AG6 003-1BB06-0DA0 3 Extreme bundles with IEC 60870-5-104 telecontrol protocol (TCP/IP) Standard bundles with IEC 60870-5-104 telecontrol protocol (TCP/IP) SIPLUS RIC S7-300 bundle T104 MA/SL CPU314 CP343-1 MMC 128 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 314 including 128 KB Micro Memory Card, CP 343-1 Lean 6AG6 003-1BB01-7BA0 SIPLUS RIC S7-300 bundle T104 MA/SL CPU314C-2 PN/DP MMC 512 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 314C-2 DP including 512 KB Micro Memory Card 6AG6 003-1BB07-0CA0 SIPLUS RIC S7-300 bundle T104 MA/SL CPU315 CP343-1 MMC 512 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 315-2 DP including 512 KB Micro Memory Card, CP 343-1 Lean 6AG6 003-1BB02-7CA0 SIPLUS RIC S7-300 bundle T104 MA/SL CPU315-2 PN/DP CP343-1 MMC 512 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 315-2 PN/DP including 512 KB Micro Memory Card, CP 343-1 6AG6 003-1BB03-8CA0 SIPLUS RIC S7-300 Extreme bundle T104 MA/SL CPU315-2 PN/DP MMC 512 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 315-2 PN/DP including 512 KB Micro Memory Card 6AG6 003-2BB03-0CA7 SIPLUS RIC S7-300 Extreme bundle T104 MA/SL CPU315-2 PN/DP MMC 2 MB SIPLUS RIC IEC 60870-5-104 master/slave with SIPLUS S7-CPU 315-2 PN/DP including 2 MB Micro Memory Card 6AG6 003-2BB03-0DA7 SIPLUS RIC S7-300 Extreme bundle T104 MA/SL CPU317-2 PN/DP MMC 2 MB SIPLUS RIC IEC 60870-5-104 master/slave with SIPLUS S7-CPU 317-2 PN/DP including 2 MB Micro Memory Card 6AG6 003-2BB05-0DA7 Siemens ST PCS 7 AO · 2013 3/15 © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to control center in SIMATIC PCS 7 ■ Bestelldaten 3 Order No. Order No. Bundles with SIMATIC S7-400 controller; up to approx. 5 000 information/data points Extreme bundles with IEC 60870-5-104 telecontrol protocol (TCP/IP), without Memory Card Runtime software and electronic documentation, 2 languages (English, German), software class A, single license for 1 installation SIPLUS RIC S7-400 Extreme bundle T104 MA/SL CPU412-2 PN SIPLUS RIC IEC 60870-5-104 master/slave with SIPLUS S7-CPU 412-2 PN without Memory Card 6AG6 003-4BB15-0AA0 SIPLUS RIC S7-400 Extreme bundle T104 MA/SL CPU414-3 PN/DP SIPLUS RIC IEC 60870-5-104 master/slave with SIPLUS S7-CPU 414-3 PN/DP without Memory Card 6AG6 003-4BB04-0AA0 SIPLUS RIC S7-400 Extreme bundle T104 MA/SL CPU414-3 PN/DP SIPLUS RIC IEC 60870-5-104 master/slave with SIPLUS S7-CPU 414-3 PN/DP without Memory Card 6AG6 003-4BB07-0AA0 Standard bundles with IEC 60870-5-101 telecontrol protocol (serial) SIPLUS RIC S7-400 bundle T101 MA/SL CPU412-1 CP441-1 MC 256 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC S7-CPU 412-1 including 256 KB Memory Card, CP 441-1 with one RS 232 interface 6AG6 003-3BA00-1BA0 SIPLUS RIC S7-400 bundle T101 MA/SL CPU412-1 CP441-2 MC 256 KB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC S7-CPU 412-1 including 256 KB Memory Card, CP 441-2 with two RS 232 interfaces 6AG6 003-3BA00-4BA0 SIPLUS RIC S7-400 bundle T101 MA/SL CPU412-2 PN CP441-2 MC 1 MB SIPLUS RIC IEC 60870-5-101 master/slave with SIMATIC S7-CPU 412-1 including 1 MB Memory Card, CP 441-1 with one RS 232 interface 6AG6 003-3BA15-1CA0 SIPLUS RIC IEC on S7 Runtime software for one automation system, 2 languages (English, German), software class A, single license for 1 installation Delivery package: Certificate as well as CD-ROM with software and electronic documentation (German/English) Standard bundles with IEC 60870-5-104 telecontrol protocol (TCP/IP) SIPLUS RIC S7-400 bundle T104 MA/SL CPU412-1 CP443-1 MC 256 KB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 412-1 including 256 KB Memory Card, CP 443-1 6AG6 003-3BB00-7BA0 SIPLUS RIC S7-400 bundle T104 MA/SL CPU412-2 CP443-1 MC 1 MB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 412-2 including 1 MB Memory Card, CP 443-1 6AG6 003-3BB01-7CA0 SIPLUS RIC S7-400 bundle T104 MA/SL CPU412-2 PN MC 1 MB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 412-2 PN including 1 MB Micro Memory Card 6AG6 003-3BB15-0AC0 SIPLUS RIC S7-400 bundle T104 MA/SL CPU414-3 PN/DP MC 4 MB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 414-3 PN/DP including 4 MB Memory Card 6AG6 003-3BB04-0EA0 SIPLUS RIC S7-400 bundle T104 MA/SL CPU416-3 PN/DP MC 16 MB SIPLUS RIC IEC 60870-5-104 master/slave with SIMATIC S7-CPU 416-3 PN/DP including 16 MB Memory Card 6AG6 003-3BB07-0GA0 3/16 SIPLUS RIC IEC on S7 library (included in SIPLUS RIC IEC 60870-5101/-104 bundles) Siemens ST PCS 7 AO · 2013 Note: Software activation by phone • SIPLUS RIC IEC on S7 T101 MA/SL CP 441 Function block library for telecontrol protocol IEC 60870-5-101 master/slave, suitable for S7-400, CP 441 interface • SIPLUS RIC IEC on S7 T101 MA/SL CP 340/341 Function block library for telecontrol protocol IEC 60870-5-101 master/slave, suitable for S7-400/ S7-400H, CP 340/341 interface • SIPLUS RIC IEC on S7 T104 MA/SL CP 443 Function block library for telecontrol protocol IEC 60870-5-104 master/slave; suitable for S7-400/ S7-400H, CP 443-1 interface 6AG6 003-0BA11-0AA0 6AG6 003-0BA01-0AA0 6AG6 003-0BB11-0AA0 © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to control center in SIMATIC PCS 7 ■ Bestelldaten Order No. SIPLUS RIC protocol expansion Expansion of protocol IEC 60870-5-103 Master for SIPLUS RIC bundles for interfacing SIPROTEC protective equipment Additional registrations for conversion between protection data protocol IEC 60870-5-103 and telecontrol protocol IEC 60870-5-101 or IEC 60870-5-104 1) SIPLUS RIC ET 200S bundle Modbus slave with SIMATIC IM 151-8 PN/DP CPU incl. 128 KB Micro Memory Card and S7 OPEN MODBUS TCP/IP library 6AG6 003-0AC12-0AA0 6AG6 003-0AC02-0AA0 3 6AG6 003-5AE01-0BA0 Extreme bundles with Modbus RTU telecontrol protocol (TCP/IP) SIPLUS RIC ET 200S Extreme bundle Modbus slave with SIMATIC IM 151-8 PN/DP CPU incl. 128 KB Micro Memory Card and S7 OPEN MODBUS TCP/IP library 6AG6 003-6AE01-0BA7 Bundles with SIMATIC S7-300 controller; up to approx. 2 000 information/data points 6AG6 003-0AC42-0AA0 Runtime software and electronic documentation, 2 languages (English, German), software class A, single license for 1 installation Standard bundles with Modbus RTU telecontrol protocol (TCP/IP) Can only be ordered together with a SIPLUS RIC bundle! SIPLUS RIC Modbus RTU bundles for telecontrol connection to control center in SIMATIC PCS 7 Bundles with SIMATIC ET 200S (CPU integrated); up to approx. 200 information/data points Runtime software and electronic documentation, 2 languages (English, German), software class A, single license for 1 installation Standard bundles with Modbus RTU telecontrol protocol (serial) SIPLUS RIC ET 200S Bundle Modbus Slave with SIMATIC IM 151-7 CPU incl. 128 KB Micro Memory Card, 1SI module with RS 232/RS 485 interface and Modbus protocol 6AG6 003-5AD00-2BA0 SIPLUS RIC ET 200S Bundle Modbus Slave with SIMATIC IM 151-8 PN/DP CPU incl. 128 KB Micro Memory Card, 1SI module with RS 232/RS 485 interface and Modbus protocol 6AG6 003-5AD01-2BA0 Extreme bundles with Modbus RTU telecontrol protocol (serial) SIPLUS RIC ET 200S Extreme Bundle Modbus Slave with SIMATIC IM 151-7 CPU incl. 128 KB Micro Memory Card, SIPLUS 1SI module with RS 232/ RS 485 interface and Modbus protocol 6AG6 003-6AD01-2BA7 Standard bundles with Modbus RTU telecontrol protocol (TCP/IP) Runtime software, 2 languages (English, German), software class A, single license for 1 installation Delivery package: Certificate (software activation by phone) • SIPLUS RIC ZSF software T103 MA CP 4411) Additional registration SIPLUS RIC IEC 60870-5-103 Master for one S7-400 automation system; communication via CP 441 • SIPLUS RIC ZSF software T103 MA CP 340/3411) Additional registration SIPLUS RIC IEC 60870-5-103 Master for one S7-300/S7-400/S7-400H automation system; communication via CP 340/341 • SIPLUS RIC ZSF software T103 MA CP 1SI1) Additional registration SIPLUS RIC IEC 60870-5-103 Master for one ET 200S with integrated CPU (IM 151-7/8); communication via 1SI module Order No. SIPLUS RIC ET 200S Extreme bundle Modbus slave with SIMATIC IM 151-8 PN/DP CPU incl. 128 KB Micro Memory Card, SIPLUS 1SI module with RS 232/ RS 485 interface and Modbus protocol SIPLUS RIC S7-300 bundle Modbus slave with SIMATIC S7-CPU 315-2 PN/DP incl. 512 KB Micro Memory Card and S7 OPEN MODBUS TCP/IP library 6AG6 003-1AE03-0CA0 SIPLUS RIC S7-300 Bundle Modbus Slave with SIMATIC S7-CPU 317-2 PN/DP incl. 2 MB Micro Memory Card and S7 OPEN MODBUS TCP/IP library 6AG6 003-1AE05-0DA0 SIPLUS RIC S7-300 bundle Modbus slave with SIMATIC S7-CPU 319-3 PN/DP incl. 2 MB Micro Memory Card and S7 OPEN MODBUS TCP/IP library 6AG6 003-1AE06-0DA0 Extreme bundles with Modbus RTU telecontrol protocol (TCP/IP) SIPLUS RIC S7-300 Extreme bundle Modbus slave with SIMATIC S7-CPU 315-2 PN/DP incl. 512 KB Micro Memory Card and S7 OPEN MODBUS TCP/IP library 6AG6 003-2AE03-0CA7 SIPLUS RIC S7-300 Extreme bundle Modbus slave with SIMATIC S7-CPU 317-2 PN/DP incl. 512 KB Micro Memory Card and S7 OPEN MODBUS TCP/IP library 6AG6 003-2AE05-0DA7 6AG6 003-6AD00-2BA7 Siemens ST PCS 7 AO · 2013 3/17 © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to third-party control center ■ Overview ■ Application PCS 7 Add-on SIMATIC PCS 7 automation systems can also communicate with a remote third-party control center by means of the telecontrol protocol IEC 60870-5-101 (serial) or IEC 60870-5-104 (TCP/IP). Possible fields of application include: • Interfacing of power plant automation based on SIMATIC PCS 7 to network control centers for power distribution • Interfacing of pumping and compressor stations automated using SIMATIC PCS 7 to higher-level control centers for gas, oil or water pipelines The IEC 60870-5-101 protocol permits use of classic WAN connections over modems and dedicated lines. The IEC 60870-5-104 protocol supports TCP/IP-based WAN connections such as Internet/DSL or GPRS. ■ Design Note: With the telecontrol configurations described below for connection of SIMATIC PCS 7 automation systems to a thirdparty control center, use of the SIPLUS RIC IEC on S7 library is independent of SIMATIC PCS 7 TeleControl. Telecontrol connection for single SIMATIC PCS 7 automation systems (single station) Supervisory Control System (telecontrol center) separate from SIMATIC PCS 7 SIMATIC PCS 7 operator system Single station or client/server configuration Third-party system: Supervisory Control System Industrial Ethernet plant bus TCP/IP router Telecontrol network according to IEC 60870-5-104 (WAN), e.g. Internet/DSL SIMATIC PCS 7 automation systems SIPLUS RIC PCS 7 library SIPLUS RIC PCS 7 library Dedicated line modem, e.g. SINAUT MD2 G_PCS7_XX_00177 Telecontrol network according to IEC 60870-5-101 (WAN) TCP/IP router CP 441-1 Dedicated line modem, e.g. SINAUT MD2 CP 443-1 3 fit for SIMATIC PCS 7 V8 Configuration examples of the telecontrol connection of SIMATIC PCS 7 automation systems of single station design with the IEC 60870-5-101 and IEC 60870-5-104 telecontrol protocols Depending on the protocol, either the CP 441 (IEC 60870-5-101) or CP 443-1EX20/-1EX30 (IEC 60870-5-104) is used as the communication module in the automation system. The materials required to design a telecontrol link, e.g. TCP/IP router, CP 443-1EX20/-1EX30, CP 441-1, dedicated line modem, cables etc., are accessories which are not included in this catalog. 3/18 Siemens ST PCS 7 AO · 2013 In the SIMATIC PCS 7 automation system, additive driver blocks from the SIPLUS RIC IEC on S7 library carry out the interface adaptation for communication using the IEC 60870-5-101 or IEC 60870-5-104 standardized protocol. Configuration is carried out as usual for SIMATIC PCS 7 using the SIMATIC Manager. This equally applies to automation systems designed as single station or redundant station. © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to third-party control center ■ Design (continued) Telecontrol connection for redundant SIMATIC PCS 7 automation systems (redundant station) Redundant configuration with IEC 60870-5-101 telecontrol protocol (serial) Supervisory Control System (telecontrol center) separate from SIMATIC PCS 7 Dedicated line modem, e.g. SINAUT MD2 Telecontrol network according to IEC 60870-5-101 (WAN) 3 SIMATIC PCS 7 operator system Single station or client/server configuration Third-party system: Supervisory Control System Industrial Ethernet plant bus SIPLUS RIC PCS 7 library zpth{pjGwjzG^G hzG[XYoVhzG[X[oV hzG[X]oVhzG[X^o jwGZ[X Dedicated line modem, e.g. SINAUT MD2 G_PCS7_XX_00178 l{GYWWt Configuration example of the telecontrol connection of redundant SIMATIC PCS 7 AS with the IEC 60870-5-101 telecontrol protocol • The control center is linked via a serial telecontrol connection with IEC 60870-5-101 protocol to a CP 340 or CP 341 in an ET 200M station of the SIMATIC PCS 7 system. • If the master system fails, the standby system of the redundant automation system takes over data exchange with the control center bumpless via the CP 341 in the ET 200M station. • Failure of the master system can be signaled to the control center. Siemens ST PCS 7 AO · 2013 3/19 © Siemens AG 2013 Industry-specific applications Telecontrol - SIPLUS RIC Telecontrol connection to third-party control center ■ Design (continued) Redundant configuration with IEC 60870-5-104 telecontrol protocol (TCP/IP) Supervisory Control System (telecontrol center) separate from SIMATIC PCS 7 3 SIMATIC PCS 7 operator system Single station or client/server configuration Third-party system: Supervisory Control System TCP/IP router Industrial Ethernet plant bus TCP/IP router CP 443-1 Telecontrol network according to IEC 60870-5-104 (WAN) CP 443-1 SIPLUS RIC PCS 7 library G_PCS7_XX_00179 SIMATIC PCS 7 AS 412H/AS 414H/ AS 416H/AS 417H Configuration example of the telecontrol connection of redundant SIMATIC PCS 7 AS with the IEC 60870-5-104 telecontrol protocol • The control center is linked via a TCP/IP-based WAN to the SIMATIC PCS 7 system bus. • The control center establishes a TCP/IP connection to an AS subsystem with each of the two CP 443-1EX20/-1EX30 via which the redundant automation system is integrated into the system bus. • The control center starts the IEC 60870-5-104 telecontrol protocol via the TCP/IP connection to the master system and monitors the TCP/IP connection to the standby system using test frames. • If the master system fails, the control center signals the associated connection as being faulty, and starts the IEC 60870-5-104 telecontrol protocol via the TCP/IP connection to the standby system. It then attempts to reestablish the faulty connection. ■ Selection and ordering data Order No. Siemens AG Würzburger Str. 121 90766 Fürth Germany Tel.: +49 911 750 - 4790 Fax: +49 911 750 - 9917 E-mail: [email protected] www.siemens.com/siplus-ric Runtime software for one automation system, 2 languages (English, German), software class A, single license for 1 installation Delivery package: Certificate as well as CD-ROM with software and electronic documentation (German/ English) 3/20 As a specialist for complete solutions in the product and system business, we would be pleased to advise you concerning generation of an individual configuration and the selection of accessories. If required, we can also supply preconfigured bundles or turnkey outstations installed in wall enclosures, cabinets or containers. Contact address for quotation and consulting: Additional information is available on the Internet at: SIPLUS RIC IEC on S7 library Note: Software activation by phone • SIPLUS RIC IEC on S7 T101 MA/SL CP 441 Function block library for telecontrol protocol IEC 60870-5-101 master/slave; suitable for S7-400, CP 441 interface • SIPLUS RIC IEC on S7 T101 MA/SL CP 340/341 Function block library for telecontrol protocol IEC 60870-5-101 master/slave; suitable for S7-400/ S7-400H, CP 340/341 interface • SIPLUS RIC IEC on S7 T104 MA/SL CP 443 Function block library for telecontrol protocol IEC 60870-5-104 master/slave; suitable for S7-400/ S7-400H, CP 443-1 interface ■ More information 6AG6 003-0BA11-0AA0 6AG6 003-0BA01-0AA0 6AG6 003-0BB11-0AA0 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Industry-specific applications Process Analytical Technology SIMATIC SIPAT: Optimization of product development and production ■ Overview PCS 7 Add-on SIMATIC SIPAT from Siemens is the appropriate software platform for integration of PAT in the process industry. PAT can then be integrated into existing or new infrastructures. These can feature SCADA/process control systems (optionally with batch automation), Manufacturing Execution Systems (MES), Enterprise Resource Planning Systems (ERP), Laboratory Information Management Systems (LIMS), data portals, knowledge management systems, etc. Linking to the SIMATIC PCS 7 process control system by means of OPC. fit for SIMATIC PCS 7 V8 Knowledge Management ERP SIPAT R&D MES Data collection Monitoring and control Chemometrics Batch Reporting LIMS SCADA Analyzers DCS and PLC G_PCS7_XX_00218 Data mining Through application of the Process Analytical Technology (PAT) initiated by the Food & Drug Administration you can design, analyze, optimize and control product development processes and production processes on the basis of up-to-date measurements of critical quality and performance attributes of raw materials, process materials and procedures so that the quality required for the end product can be absolutely guaranteed. Intended uses for PAT: • Gaining comprehensive knowledge concerning the product and its development process • Determination of relevant factors influencing the quality of the end product from the recorded product and process data • Estimation of the end product quality through continuous analysis of the influencing factors • Early introduction of closed-loop control measures for safeguarding the quality of the end product • Safeguarding of consistent product quality when upscaling the process from laboratory operation to production and when changing production quantities • Validation of process in accordance with statutory directives • Improvement of total performance of process Important features of SIMATIC SIPAT: • Modular, scalable architecture with uniform interfaces for process analyzers and data mining applications • Can be integrated into existing or new infrastructures • Data recording: recording of product and process data using standard analyzers • Data mining: data evaluation and determination of relevant quality parameters, for example, through modeling and validation with multivariate data analysis (MVDA) • Real-time prediction of quality parameters • Continuous monitoring and control of product quality • Online visualization, report functions, and analysis of historical data • Support for simple and fast process validation • Audit functionality for compliance with statutory directives • Conformity with the directives defined in 21 CFR Part 11 with regard to version management, saving of raw data, and access privileges Note: The current software SIMATIC SIPAT V4.0 can be used together with SIMATIC PCS 7 V7.1 and V8.0. Real-time tracking of parameters relevant to product quality not only helps you to understand and control the total process better, it also helps to reduce or even completely eliminate final inspections. The preparation of samples for quality control at the end of the process (which can sometimes be extremely timeconsuming) or for follow-up checks can thus be omitted. The results obtained with PAT during product development in the laboratory can be easily upscaled to production mode. The production quantities can be rapidly and flexibly adapted to changing market requirements while keeping the quality. All these features result in very short product development and launch times with significant cost advantages. Siemens ST PCS 7 AO · 2013 3/21 3 © Siemens AG 2013 Industry-specific applications Process Analytical Technology SIMATIC SIPAT: Optimization of product development and production ■ Design Application of Process Analytical Technology (PAT) with SIMATIC SIPAT allows you to considerably increase the effectiveness and profitability of processes in the laboratory and during production. 3 The numerous advantages that you gain by using SIMATIC SIPAT are categorized as follows: 7 Considerable cost reductions - Avoidance of rejects/reworking - Reduced stocks of raw materials, intermediate products and end products - Reduction in offline laboratory costs - Flexible adaptation of production quantities depending on demand 7 Better quality and overall performance - Product approval in real-time - Guaranteed, uniformly high product quality - Higher product yield - Reduced risk of recalls - Minimized danger of contamination 7 Shorter development and product launch times - Improvement in efficiency through operative excellence - Simpler compliance with statutory directives through optimization of validation - Easier and faster process scalability - Easier and faster transfer from one system to another 7 Strengthening and improving the competitive position - Winning of market shares through faster product development and launching - Process patenting secures a lead over the competition 7 Image upgrading - Innovative product/production technologies - Compliance with legislation - Impressive process knowledge - Minimization of risk of recalls, warning notifications or declarations of consent ■ Application SIMATIC SIPAT is recommended primarily for use in the following industries: • Pharmaceutical industry • Fine chemicals • Food, beverages and tobacco industries • Paper and cellulose industries SIMATIC SIPAT Client Station SIMATIC SIPAT Database Server SIMATIC SIPAT Web Server TCP/IP SIMATIC SIPAT Collector Station and/or OPC UA ADI client SIMATIC SIPAT Base Station Instrument/ analyzer SIMATIC SIPAT Chemometrics Server Instrument/analyzer with OPC UA ADI Server G_PCS7_XX_00219 ■ Benefits Example of a distributed SIMATIC SIPAT architecture The software supplied on the SIMATIC SIPAT DVD is structured as follows: SIMATIC SIPAT Central Database Central relational database which contains both configuration and runtime data SIMATIC SIPAT Station Service Windows service for execution of methods (data collection, update, calculation) SIMATIC SIPAT Runtime Information Service Windows service for communication between distributed SIMATIC SIPAT Base Stations and the central SIMATIC SIPAT database SIMATIC SIPAT Productivity Pack Uniform interface for integration of analyzers in SIMATIC SIPAT. In combination with the device manufacturer's software, allows parameterization, calibration, and control of these devices in addition to data acquisition SIMATIC SIPAT Watchdog Service Windows service for monitoring the availability of individual SIMATIC SIPAT stations SIMATIC SIPAT Data Logger Service Windows service for saving runtime data (writing in central SIMATIC SIPAT database, buffering in event of power failure) SIMATIC SIPAT Workflow Service Windows service for online execution of workflows for parameterization/calibration of analyzers and for preparation of SIMATIC SIPAT methods 3/22 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Industry-specific applications Process Analytical Technology SIMATIC SIPAT: Optimization of product development and production ■ Design (continued) SIMATIC SIPAT Umetrics Server Windows service for online execution of models of the following Umetrics software products: • Umetrics SIMCA QP+ • Umetrics SIMCA P+ • Umetrics SBOL SIMATIC SIPAT OPC Services (Automation Service, Writer Service, Alarm Service) Windows services for OPC data exchange with SCADA/process control systems (DCS), e.g. SIMATIC PCS 7 SIMATIC SIPAT Archiver Service SIMATIC SIPAT CAMO Server Windows service for long-term archiving of SIPAT runtime data in an XML file (archived data can be removed from the runtime database, SIMATIC SIPAT Central Database). Windows service for online execution of models of the following CAMO software products: • Camo Unscrambler OLUP • Camo Unscrambler OLUC This distributed software structure can be flexibly mapped on different PC-based hardware configurations (e.g. SIMATIC Industrial PC) depending on the process size and customer requirements. SIMATIC SIPAT Matlab Server Windows service for online execution of the Matlab models SIMATIC SIPAT Client SIMATIC SIPAT user interface for access to data of the SIMATIC SIPAT database. It supports the following functions: • Configuring SIMATIC SIPAT methods and creating the required chemometric models • Controlling and visualizing execution of the methods All software components can be executed on a SIMATIC Industrial PC (IPC). For reasons of improved performance, however, distributed IPC architectures are characteristic of SIMATIC SIPAT V4.0 (see graphic: "Example of a distributed SIMATIC SIPAT architecture"). The following table shows the hardware assignment of the software components for the recommended SIMATIC SIPAT V4.0 architecture: Hardware component (IPC) - functional name SIMATIC SIPAT software component Comments SIMATIC SIPAT Database Server SIMATIC SIPAT Central Database MS SQL and Oracle are supported; Oracle must be executed on a Windows server. SIMATIC SIPAT Base Station SIMATIC SIPAT Station Service Typically for up to four methods SIMATIC SIPAT Productivity Pack SIMATIC SIPAT Watchdog Service SIMATIC SIPAT Data Logger Service SIMATIC SIPAT Workflow Service SIMATIC SIPAT Umetrics Server SIMATIC SIPAT CAMO Server Can also be installed on a separate Chemometrics server; one SIMATIC SIPAT Umetrics/Camo/Matlab server per basic operation is preferred. SIMATIC SIPAT Matlab Server SIMATIC SIPAT Collector Station SIMATIC SIPAT Productivity Pack SIMATIC SIPAT Watchdog Service SIMATIC SIPAT Workflow Service SIMATIC SIPAT Client Station SIMATIC SIPAT Client SIMATIC SIPAT OPC Server SIMATIC SIPAT OPC Services Known DCOM properties can be avoided if the SIMATIC SIPAT OPC Services are installed on the OPC server; they can also be installed on an existing OPC server. SIMATIC SIPAT Archive Server SIMATIC SIPAT Archiver Service Can also be installed on an existing archive server. SIMATIC SIPAT Chemometrics Server SIMATIC SIPAT Umetrics Server, SIMATIC SIPAT Alternative, customer-specific CAMO Server or SIMATIC SIPAT Matlab Server Siemens ST PCS 7 AO · 2013 3/23 3 © Siemens AG 2013 Industry-specific applications Process Analytical Technology SIMATIC SIPAT: Optimization of product development and production ■ Design (continued) Other possibilities for flexible adaptation to the technological process result from the license model which is fixed in the product range of SIMATIC SIPAT V4.0. It is defined as follows: SIMATIC SIPAT SIMATIC SIPAT Base Station (4 methods) 3 Full license includes: • 4 x SIMATIC SIPAT Concurrent Method • 1 x SIMATIC SIPAT Productivity Pack Analyser Type SIMATIC SIPAT Base Station is the PAT application for a production unit. It uses the data from one or more analyzers together with the data in the environment of existing systems (DCS, SCADA, MES, ERP, LIMS, or Historian) for the determination of "Qualitative Process Fingerprints" or the prediction of "Critical-to-Quality" parameters. To this end it collects run-time data from the various sources using configurable methods, matches these with each other, and carries out complex calculations. All recorded production, configuration and Audit Trail data is saved together with user-specific context information in the SIMATIC SIPAT Central Database. The data can be used to improve understanding of the process and to optimize the process. SIMATIC SIPAT Basic Package (1 method) The SIMATIC SIPAT Basic Package bundles a SIMATIC SIPAT Base Station license with a SIMATIC SIPAT Concurrent Method license (1 method), a SIMATIC SIPAT Data Miner license, and a SIMATIC SIPAT Productivity Pack Analyser Type license. SIMATIC SIPAT Base Station (w/o methods) In contrast to SIMATIC SIPAT Base Station (4 methods), this package does not contain SIMATIC SIPAT Concurrent Method or SIMATIC SIPAT Productivity Pack Analyser Type licenses. SIMATIC SIPAT Concurrent Method (1 method) The SIMATIC SIPAT Concurrent Method expands a SIMATIC SIPAT Base Station or a SIMATIC SIPAT Basic Package by one method in each case, to up to four simultaneously executed methods. SIMATIC SIPAT Productivity Pack (Analyser Type/Analyser) The SIMATIC SIPAT Productivity Pack integrates analyzers via uniform interfaces, so-called instrument collectors, in SIMATIC SIPAT. The instrument collectors are used for bidirectional data exchange with analyzers. They use device software and interfaces of the device manufacturers (manufacturer's software license required). Each instrument collector of a particular type serves as a driver for the individual instruments of this type. Instrument collectors for the following types of device are currently available: • ABB Bomem • Bruker OPUS • Bruker Lancir • Dr. Schleuniger / Bruker Tandem • Malvern Insitec Particle Size • Malvern Morphology • Thermo Fisher Antaris • Kaiser Optics • Granumet XP • Malvern Morphology • Brimrose Luminar • Expo ePAT601 • Carl Zeiss 500/600 SIMATIC SIPAT Productivity Pack OPC UA Analyser This SIMATIC SIPAT Productivity Pack integrates analyzers with their own OPC UA ADI server. SIMATIC SIPAT communicates with the device-specific server via the OPC UA ADI client. SIMATIC SIPAT OPC UA ADI Server Toolkit This toolkit includes the source code and runtime models to support a device-specific OPC UA ADI server. SIMATIC SIPAT Reporting Framework The SIMATIC SIPAT Reporting Framework license permits use of the SIMATIC SIPAT data for reporting with Microsoft Reporting Services. SIMATIC SIPAT Concurrent Method (unlimited) SIMATIC SIPAT Demo Version This license authorizes an unlimited number of methods. It is subject to a contractual agreement which requires a regular report on the runtime of the methods. The SIMATIC SIPAT Demo Version license limits the duration of use of SIMATIC SIPAT to 180 days. The SIMATIC SIPAT Demo Version includes: • 1 x SIMATIC SIPAT Base Station (4 methods) • 2 x SIMATIC SIPAT Productivity Pack Analyser Type • 4 x SIMATIC SIPAT Productivity Pack Analyser • 4 x SIMATIC SIPAT Productivity Pack OPC UA Analyser • 1 x SIMATIC SIPAT Data Miner SIMATIC SIPAT Data Miner The SIMATIC SIPAT Data Miner is typically used offline to process historical data and to transfer it to chemometric software. The SIMATIC SIPAT Data Miner carries out version assignment and administration (lifecycle) for the MVDA model determined by the chemometric software. It also supports validation and optimization of these models. SIMATIC SIPAT Test Environment SIMATIC SIPAT Test Environment allows you to design a test system (mapping of a production plant) for new SIMATIC SIPAT versions or new customer developments. It includes: • 1 x SIMATIC SIPAT Base Station (unlimited methods) • 4 x SIMATIC SIPAT Productivity Pack Analyser Type • 8 x SIMATIC SIPAT Productivity Pack Analyser • 8 x SIMATIC SIPAT Productivity Pack OPC UA Analyser • 1 x SIMATIC SIPAT Data Miner 3/24 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Industry-specific applications Process Analytical Technology SIMATIC SIPAT: Optimization of product development and production ■ Design (continued) ■ Function SIMATIC SIPAT EXPRESS Important functions of SIMATIC SIPAT V4.0: SIMATIC SIPAT EXPRESS is the name of the OEM version of SIMATIC SIPAT. OEMs have the option of equipping their products with a preconfigured SIMATIC SIPAT EXPRESS, which the customer can use in this form, but cannot modify. The following SIMATIC SIPAT EXPRESS licenses are available: Data acquisition 3 SIMATIC SIPAT EXPRESS Base Station OEM version of the SIMATIC SIPAT Base Station SIMATIC SIPAT EXPRESS Concurrent Method (1 method) OEM version of the SIMATIC SIPAT Concurrent Method SIMATIC SIPAT EXPRESS Data Miner OEM version of the SIMATIC SIPAT Data Miner SIMATIC SIPAT EXPRESS Productivity Pack (Analyser Type/Analyser) OEM version of the SIMATIC SIPAT Productivity Pack (Analyser Type/Analyser) SIMATIC SIPAT EXPRESS Productivity Pack OPC UA Analyser OEM version of the SIMATIC SIPAT Productivity Pack OPC UA Analyser SIMATIC SIPAT EXPRESS Reporting Framework OEM version of the SIMATIC SIPAT Reporting Framework SIMATIC SIPAT EXPRESS Productivity Pack SIPAT This Productivity Pack allows you to integrate a SIMATIC SIPAT EXPRESS Base Station into a SIMATIC SIPAT system. This process revokes the EXPRESS version restrictions concerning modifications and expansions. SIMATIC SIPAT EXPRESS Engineering Station The SIMATIC SIPAT EXPRESS Engineering Station allows you to configure and service a SIMATIC SIPAT EXPRESS system. Recording of process analysis data SIMATIC SIPAT can be used together with various analyzers to record product and process data. Depending on the devicespecific functions and the software support provided by the manufacturer, SIMATIC SIPAT cannot just be used for data acquisition, but also for configuration of the analyzer, including calibration and system performance test. Receipt/reading of data and data distribution SIMATIC SIPAT uses open technologies based on industrial standards for data exchange with external systems, for example, with the SIMATIC PCS 7 process control system. SIMATIC SIPAT can read in process parameters such as temperature, pressure or pH value for application in a PAT procedure via an OPC interface. OPC communication can also be used to inform SIMATIC SIPAT about the beginning or end of a batch, procedure or phase. In addition to the online data of analyzers and the SIMATIC PCS 7 process control system, SIMATIC SIPAT can also use quality parameters from ERP systems, LIMS systems such as SIMATIC IT Unilab, or MES systems such as SIMATIC IT Production Suite, such as the results of a raw material analysis. Device calibration and system performance test The performance of analyzers is usually checked before they are put into use. SIMATIC SIPAT takes this workflow into account, and triggers a calibration or a system performance test on the basis of internal or external standards. For tracking purposes, SIMATIC SIPAT saves the results as well as other data recorded with this device. Siemens ST PCS 7 AO · 2013 3/25 © Siemens AG 2013 Industry-specific applications Process Analytical Technology SIMATIC SIPAT: Optimization of product development and production ■ Function (continued) Data mining Monitoring and open-loop control 3 The Data Miner is used to preprocess the product and process data recorded with SIMATIC SIPAT. It can be used to evaluate data and to design and validate models. SIMATIC SIPAT records data during runtime, preprocesses it and, if necessary, can use models in the background to provide predictions. The results can be visualized and/or distributed with SIMATIC SIPAT. SIMATIC SIPAT can work together with different types of data mining or MVDA software packages. Chemometric functions from Umetrics are already integrated as standard in SIMATIC SIPAT. The models are saved with version and status data in the SIMATIC SIPAT archive. It is unnecessary to combine all predictions for a specific PAT procedure in one single model. A procedure can include several models which can be arranged hierarchically or in parallel. The data required for this purpose can be used repeatedly. In contrast to other PAT systems, which are usually limited to a model of an analyzer or perhaps to an additional model of a single procedure, SIMATIC SIPAT can be used to develop a general process model that enables the end product quality parameters to be predicted. Model types • Model of a single analyzer Model on the basis of the recorded data of a particular analyzer, for example, through creation of a near infrared procedure (NIR), the prediction of specific parameters, principal component analysis (PCA) or a partial least squares procedure (PLS) • Model of a single procedure Model on the basis of the recorded data of a particular single procedure (data from sensors, analyzers etc.), for example, a combination of pH value, temperature, pressure, dissolved oxygen and NIR data during operation of a single bioreactor • Host process/product (range) model Model on the basis of the recorded data of various single procedures of the total process range - from the raw materials up to the end product. This model is a special feature of SIMATIC SIPAT. 3/26 Siemens ST PCS 7 AO · 2013 Integration in the batch The model of a single procedure or of the process is used as the basis for development of a model for process control (feedback and feedforward control/correction). SIMATIC SIPAT is responsible for the quality aspects of the process, and provides the corresponding information for the SCADA/process control system. The SCADA/process control system implements the control measures required to guarantee the quality. To implement the feedforward/feedback control, the two systems are connected in real-time via an OPC interface. The close connection to a batch system for batch process automation permits synchronization of the recipe-based procedures with SIMATIC SIPAT. SIMATIC SIPAT can then define the end conditions for a particular procedure or phase, for example. Visualization of data The graphic user interface (GUI) of SIMATIC SIPAT permits you to record data interactively, to create new PAT procedures, or to view additional information on current or historical production batches. All critical quality parameters can be monitored online. The process can be monitored by comparing plotter parameters with the golden batch series. Visualization takes place either using the SCADA/process control system or the graphic user interface of SIMATIC SIPAT. Feedback for SCADA/process control system SIMATIC SIPAT can be configured so that predicted parameters critical to the quality can be returned to the SCADA/process control system. These can then be used by the SCADA/process control system for control using traditional PID controllers or Advanced Process Control (APC) technologies. SIMATIC SIPAT can send prediction values or principal components online to the SCADA/process control system and to any OPC servers. ERP and MES systems can also be integrated as outputs. A typical application example is the transfer of information concerning one or more critical quality parameters to an MES or ERP system to approve a batch following a particular single procedure. © Siemens AG 2013 Industry-specific applications Process Analytical Technology SIMATIC SIPAT: Optimization of product development and production ■ Function (continued) Logging Audit functionality SIMATIC SIPAT is provided with a comprehensive audit functionality which supports quality assurance of the production sequences in accordance with the guidelines for Good Manufacturing Practice (GMP) in the pharmaceutical industry and in the food and fodder industry. This guideline conforms with the corresponding statutory directives, in particular the Food and Drug Administration (FDA) guidelines anchored in 21 CFR Part 11. The most important audit function blocks include: • System security and authorization checks • Electronic signatures • Recording of all changes to data sets (including information on who, what, and why) • Storage of documents and repeatability in the online database as well as in the archived data • Version check for objects such as PAT procedures, models, device settings, etc. Customized adjustments SIMATIC SIPAT saves all data measured and calculated during the operative execution of a PAT procedure together with the available batch information in a database. This data is available for evaluation using any logging tools. SIMATIC SIPAT supports logging with: • Predefined or user-specific reports • Logging module for creation of CSV files using universal database queries The logs present in CSV format can be imported into statistics programs or Microsoft Office applications. The standard functionality provided with SIMATIC SIPAT for design, analysis, optimization and control of product development and production on the basis of up-to-date measurements of critical quality and performance attributes of raw materials, process materials and procedures is extremely comprehensive and versatile. It can be easily configured by trained users via the SIMATIC SIPAT graphic user interface (GUI). The sequences which can be implemented with the SIMATIC SIPAT standard functions can be adapted and expanded by means of user-specific functions and workflows. Siemens ST PCS 7 AO · 2013 3/27 3 © Siemens AG 2013 Industry-specific applications Process Analytical Technology SIMATIC SIPAT: Optimization of product development and production ■ Selection and ordering data Order No. SIMATIC SIPAT V4.0 software and licenses SIMATIC SIPAT Base Station (4 methods) V4.0 for simultaneous use of up to 4 SIMATIC SIPAT methods on a distributed SIMATIC SIPAT Base Station 3 6DL5 422-8XB04-0BA5 Requirement: 1 x SIMATIC SIPAT Base Station Type of delivery: Certificate of license and product information Including 4 x SIMATIC SIPAT Concurrent Method and 1 x SIMATIC SIPAT Productivity Pack Analyser Type Note: available only with a SIMATIC SIPAT support contract. Electronic documentation on DVD "SIMATIC SIPAT V4.0", 1 language (English) Requirement: available only with a SIMATIC SIPAT support contract. Type of delivery: License key on USB stick, certificate of license, product information, and DVD "SIMATIC SIPAT V4.0" 6DL5 422-8XA04-0BA5 SIMATIC SIPAT Concurrent Method (unlimited) V4.0 for simultaneous use of an unlimited number of SIMATIC SIPAT methods 6DL5 422-1BX04-0BB5 Runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user SIMATIC SIPAT Data Miner V4.0 for one simultaneous user per SIMATIC SIPAT database 6DL5 422-1CA04-0BB5 Engineering software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user Electronic documentation, 1 language (English), on DVD "SIMATIC SIPAT V4.0" Requirement: 1 x SIMATIC SIPAT Base Station Requirement: available only with a SIMATIC SIPAT support contract. Type of delivery: Certificate of license and product information Type of delivery: License key on USB stick, certificate of license, product information, and DVD "SIMATIC SIPAT V4.0" 6DL5 422-1AX04-0BA5 SIMATIC SIPAT EXPRESS Data Miner V4.0 OEM version of SIMATIC SIPAT Data Miner V4.0 6DL5 422-4CA04-0BB5 SIMATIC SIPAT Productivity Pack Analyser Type V4.0 for installation of the first analyzer of a type 6DL5 422-1DA04-0BB5 Runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user Electronic documentation on DVD "SIMATIC SIPAT V4.0", 1 language (English) Requirement: available only with a SIMATIC SIPAT support contract. Requirement: 1 x SIMATIC SIPAT Base Station Type of delivery: Certificate of license and product information Type of delivery: License key on USB stick, certificate of license, product information, and DVD "SIMATIC SIPAT V4.0" 3/28 6DL5 422-4BA04-0BB5 Type of delivery: Certificate of license and product information Including 1 x SIMATIC SIPAT Productivity Pack Analyser Type and 1 x SIMATIC SIPAT Data Miner SIMATIC SIPAT EXPRESS Base Station V4.0 OEM version of SIMATIC SIPAT Base Station V4.0 SIMATIC SIPAT EXPRESS Concurrent Method (1 method) V4.0 OEM version of SIMATIC SIPAT Concurrent Method (1 method) V4.0 Requirement: 1 x SIMATIC SIPAT Base Station Engineering and runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user SIMATIC SIPAT Base Station (w/o methods) V4.0 Engineering and runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user 6DL5 422-1BA04-0BB5 Runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user Engineering and runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user SIMATIC SIPAT Basic Package (1 method) V4.0 for simultaneous use of one SIMATIC SIPAT method on a distributed SIMATIC SIPAT Base Station Order No. SIMATIC SIPAT Concurrent Method (1 method) V4.0 for simultaneous use of one SIMATIC SIPAT method 6DL5 422-4AX04-0BA5 Siemens ST PCS 7 AO · 2013 SIMATIC SIPAT EXPRESS Productivity Pack Analyser Type V4.0 OEM version of SIMATIC SIPAT Productivity Pack Analyser Type V4.0 6DL5 422-4DA04-0BB5 © Siemens AG 2013 Industry-specific applications Process Analytical Technology SIMATIC SIPAT: Optimization of product development and production ■ Bestelldaten SIMATIC SIPAT Productivity Pack Analyser V4.0 for installation of an additional analyzer of the same type following installation of the first analyzer Order No. 6DL5 422-1DA04-1BB5 Runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user Requirement: 1 x SIMATIC SIPAT Base Station Type of delivery: Certificate of license and product information SIMATIC SIPAT EXPRESS Productivity Pack Analyser V4.0 OEM version of SIMATIC SIPAT Productivity Pack Analyser V4.0 6DL5 422-4DA04-1BB5 SIMATIC SIPAT Productivity Pack OPC UA Analyser V4.0 for installation of an analyzer connected via OPC UA ADI 6DL5 422-1DA04-2BB5 Runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user Type of delivery: Certificate of license and product information SIMATIC SIPAT EXPRESS Productivity Pack OPC UA Analyser V4.0 OEM version of SIMATIC SIPAT Productivity Pack OPC UA Analyser V4.0 6DL5 422-4DA04-2BB5 SIMATIC SIPAT OPC UA ADI Server Toolkit V4.0 Source code and runtime models to support a device-specific OPC UA ADI server. On request SIMATIC SIPAT Reporting Framework V4.0 for a SIMATIC SIPAT database server 6DL5 422-1FA04-0BB5 6DL5 422-8XD04-0BT7 3 Including: • 1 x SIMATIC SIPAT Base Station (4 methods) • 2 x SIMATIC SIPAT Productivity Pack Analyser Type • 4 x SIMATIC SIPAT Productivity Pack Analyser • 4 x SIMATIC SIPAT Productivity Pack OPC UA Analyser • 1 x SIMATIC SIPAT Data Miner Electronic documentation on DVD "SIMATIC SIPAT V4.0", 1 language (English) Type of delivery: License key on USB stick, certificate of license, product information, and DVD "SIMATIC SIPAT V4.0" SIMATIC SIPAT Test Environment V4.0 Engineering and runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user Requirement: 1 x SIMATIC SIPAT Base Station 6DL5 422-8XC04-0BA5 Including: • 1 x SIMATIC SIPAT Base Station (unlimited methods) • 4 x SIMATIC SIPAT Productivity Pack Analyser Type • 8 x SIMATIC SIPAT Productivity Pack Analyser • 8 x SIMATIC SIPAT Productivity Pack OPC UA Analyser • 1 x SIMATIC SIPAT Data Miner Electronic documentation on DVD "SIMATIC SIPAT V4.0", 1 language (English) Type of delivery: License key on USB stick, certificate of license, product information, and DVD "SIMATIC SIPAT V4.0" Runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user SIMATIC SIPAT Productivity Pack SIPAT EXPRESS V4.0 for integration of a SIMATIC SIPAT EXPRESS Base Station Requirement: 1 x SIMATIC SIPAT Base Station Type of delivery: Certificate of license and product information SIMATIC SIPAT EXPRESS Reporting Framework V4.0 OEM version of SIMATIC SIPAT Reporting Framework V4.0 Order No. SIMATIC SIPAT Demo Version V4.0 Engineering and runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, demo license for 180 days 6DL5 422-4FA04-0BB5 6DL5 422-1EA04-0BB5 Runtime software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user Requirement: 1 x SIMATIC SIPAT Base Station and 1 x SIMATIC SIPAT EXPRESS Base Station Type of delivery: Certificate of license and product information Siemens ST PCS 7 AO · 2013 3/29 © Siemens AG 2013 Industry-specific applications Process Analytical Technology SIMATIC SIPAT: Optimization of product development and production ■ Bestelldaten 3 SIMATIC SIPAT EXPRESS Engineering Station V4.0 Engineering software, 1 language (English), software class A, runs with Windows XP Professional, Windows Server 2003 R2, Windows 7 Ultimate, or Windows Server 2008, floating license for 1 user Order No. 6DL5 422-8EA04-0BA5 Including: • 1 x SIMATIC SIPAT Base Station (4 methods) and 1 x SIMATIC SIPAT EXPRESS Base Station • 2 x SIMATIC SIPAT Productivity Pack Analyser Type and 2 x SIMATIC SIPAT EXPRESS Productivity Pack Analyser Type • 4 x SIMATIC SIPAT Productivity Pack Analyser and 4 x SIMATIC SIPAT EXPRESS Productivity Pack Analyser • 4 x SIMATIC SIPAT Productivity Pack OPC UA Analyser and 4 x SIMATIC SIPAT EXPRESS Productivity Pack OPC UA Analyser • 1 x SIMATIC SIPAT Data Miner and 1 x SIMATIC SIPAT EXPRESS Data Miner • 1 x SIMATIC SIPAT Reporting Framework and 1 x SIMATIC SIPAT EXPRESS Reporting Framework Electronic documentation on DVD "SIMATIC SIPAT V4.0", 1 language (English) Requirement: available only with a SIMATIC SIPAT support contract. Type of delivery: License key on USB stick, certificate of license, product information, and DVD "SIMATIC SIPAT V4.0" ■ More information Siemens AG Industry Sector Industry Automation Division Industrial Automation Systems Karlsruhe E-mail: [email protected] You can find more information on the Internet at: www.siemens.com/sipat 3/30 Siemens ST PCS 7 AO · 2013 Order No. SIMATIC SIPAT support contracts SIMATIC SIPAT Concurrent Method Support incl. SUS 5 days/week (Monday to Friday) in one of the three following time zones, in each case in the corresponding time period: Asia: 01:00 to 10:00 GMT North America: 14:00 to 01:00 GMT Europe: 08:00 to 17:00 GMT Must be ordered 1 x per SIMATIC SIPAT Concurrent Method and always for all SIMATIC SIPAT Concurrent Methods Including SIPAT Software Update Service (SUS) Type of delivery: SIPAT SUS contract, product information, and DVD "Service & Support Knowledge Base" 6DL5 422-1BA00-0BL8 4 © Siemens AG 2013 Operator control and monitoring 4/2 OPD: Operator dialog with electronic signatures 4/3 Alarm Control Center: Signaling faults by means of telecommunication 4/4 Premium Server for SIMATIC PCS 7 4/6 Large-screen systems for control rooms 4/8 KVM extender: Operator channel extensions 4/10 KVM matrix switches: Flexible operator station administration 4/14 Visor: Video technology for process monitoring 4/15 SIMATIC HMI Thin Client Ex 4/18 Mouse-Trak: Trackball 4/19 Device manager for SIMATIC logon 4/20 Operator's ToolSet Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Operator control and monitoring OPD: Operator dialog with electronic signatures ■ Overview ■ Function PCS 7 Add-on fit for SIMATIC PCS 7 V8 Application Operator interaction in an SFC phase An OPD can be used in an SFC phase. The simplest interaction is a request to the operator to confirm an OPD message before progressing to the next step of the phase. A second application example is a request to the operator to select one of two storage tanks. Electronic signatures may be necessary in both cases. Operator interaction between two SFC phases At the batch level, OPD can also be used for operator interaction between two separate SFC phases. For example, the operator can be requested to select between different technical equipment which require separate subsystem assignments. 4 Operator interaction for event-based actions OPD can also be used for event-based actions. An example is the request to an operator to acknowledge an OPD message before opening a valve or closing a pump. Electronic signatures The software operator dialog (OPD) simplifies the interaction between operating personnel and process control system. As a powerful operator tool, it facilitates control of the process and provides complete proof of all manual operations, which is essential for a validated batch system. The OPD software, which can be executed in a SIMATIC PCS 7/ SIMATIC BATCH system environment, is based on the Microsoft SQL server software. It uses the SIMATIC logon for user verification and electronic signatures. It therefore complies with the validation requirements according to 21 CFR Part 11 and other statutory directives. As a result of the flexible design, the OPD functionality can easily be adapted to any SIMATIC PCS 7 project. Note: OPD can be used together with SIMATIC PCS 7 V7 and V8. The OPD software provides two different possibilities for handling electronic signatures: • The signatures can be saved in the form of WinCC messages. • The signatures can be saved in a Microsoft SQL server database. Saving of electronic signatures as WinCC messages provides the advantage that they can be automatically recorded in the SIMATIC Batch standard report. They can additionally be transferred to any MES system which provides long-term archiving of SIMATIC PCS 7 process data. OPD messages OPD messages are configured by means of the user-friendly OPDEdit engineering tool. Version assignment of OPD messages is carried out automatically. OPDEdit provides a complete revision log of all modifications. Each OPD message can have the following content: • 1 text message • 0 to 10 process values (string or real) • 0 to 10 operator inputs (string or real) • 0 to 3 option groups with up to 6 option boxes • 0 to 3 control groups with up to 6 control boxes • 0 to 5 electronic signatures Further features • Redundant database server • Multi-client capability • Secure identifier (SID) ■ More information PlantVision Kista Science Tower SE-16451 Kista Sweden E-mail: [email protected] Additional information is available on the Internet at: www.plantvision.se 4/2 Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Operator control and monitoring Alarm Control Center: Signaling faults by means of telecommunication ■ Overview PCS 7 Add-on ■ Selection and ordering data fit for SIMATIC PCS 7 V8 In modern control systems, the fast and reliable signaling of fault statuses and the alarming of responsible persons is becoming increasingly important. The modular alarm management system "Alarm Control Center" addresses these demands by sending SIMATIC PCS 7 error messages fully automatically to a host of possible recipients (text message to cellphone, fax, voice message, e-mail etc.). The various versions of the Alarm Control Center and the options available permit individual adaptation to user requirements, ranging from stand-alone solutions up to company-wide communications solutions. Note: The Alarm Control Center can operate together with SIMATIC PCS 7 V7 and V8. ■ Function • Radio channels included in the basic system: - SMS to mobile phone - Fax output - Output on message printer • Further communications media are supported as options: - Sending of SMS via GSM modem with facility for acknowledgment - Voice output, also with language synthesis - Pager - E-mail - Telephone systems such as Siemens HiPath/Hicom and Ascom via OAP - Many further options, also customized • Integral shift and personnel management for time-dependent sending of messages • Comprehensive escalation system for reliable delivery of messages even if individual receivers cannot be reached • Operation and configuration throughout the network thanks to Web capability • Available with redundant solutions Order No. Alarm Control Center "Basic Edition" Core system for local installation on a SIMATIC PCS 7 station 9AE4 310-3BS01 Alarm Control Center "Professional Edition" Core system for connection of several (max. 6) SIMATIC PCS 7 stations (also redundant systems) 9AE4 310-3BS02 Alarm Control Center "Enterprise Edition" Core system for connection of several (more than 6) SIMATIC PCS 7 stations (also redundant systems) 9AE4 310-3BS03 PCS 7 Agent for Alarm Control Center Connection of a (further) SIMATIC PCS 7 system to the Alarm Control Center via LAN (one license already included with each core system) 9AE4 310-3PW02 Alarm Control Center transmitter channel "SMS via GSM modem, dual-band" For direct sending of text messages in the GSM network with acknowledgment function (including dualband hardware for use in Europe) 9AE4 310-3FG10 Alarm Control Center transmitter channel "SMS via GSM modem, quad-band" For direct sending of text messages in the GSM network with acknowledgment function (including quadband hardware for global use) 9AE4 310-3FG12 Alarm Control Center transmitter channel "Voice output" Voice output (WAV files) to any phone, requires ISDN card 9AE4 310-3FV10 Alarm Control Center transmitter channel "E-mail" Sending of e-mail via SMTP server 9AE4 310-3FE10 4 Note: Information on other configurations and options can be found at the Internet address specified below. ■ More information Siemens AG Industry Sector WinCC and Alarm Management Competence Center Stuttgart/Germany Tel.: +49 711 137 3935 Fax: +49 711 137 2781 E-mail: Sales: [email protected] Delivery: [email protected] Support: [email protected] Additional information is available on the Internet at: www.siemens.de/alarmcc Siemens ST PCS7 AO · 2013 4/3 © Siemens AG 2013 Operator control and monitoring Premium Server for SIMATIC PCS 7 ■ Overview ■ Technical specifications General features PCS 7 Add-on fit for SIMATIC PCS 7 V8 4 In addition to the SIMATIC PCS 7 Industrial Workstations offered in the ST PCS 7 catalog, we offer you the innovative Premium Server for SIMATIC PCS 7 - an attractive, powerful and flexible basic server system for the upper performance range of the SIMATIC PCS 7 process control system V7. The Premium Server is a professional and reliable workgroup server with two quad-core Intel Xeon processors, built as standard into a 19" rack housing of 4 height units (HU). It can be used as an OS server, but also as an archive, batch or route control server, etc. Compatibility with the SIMATIC PCS 7 process control system has been proven by extensive tests. Operating system Pre-installed Microsoft Windows Server 2008 R2 SP1 Standard 64-bit, multi-language operating system including 5 client access licenses (CAL) Server management Server management with InventoryView, alarm and SNMP management Processor Dual-Quad Intel Xeon processor technology Main memory 8 GB RAM DDR3-1333 PC3-10600 rg ECC expandable up to 768 GB Hard disk 2 x hot-plug SAS hard disks as RAID1 array (version "Extended HDD capacity": 6 x hot-plug SAS hard disks as RAID5 array) Network connection (not enabled for redundant mode) 2 x RJ45-TP LAN connection onboard (10/100/1000) Plant bus connection (optional) CP 1623 communication module (6GK1 162-3AA00) Additional provision if necessary (installation free of charge). 2 units are required for redundant connection. Redundant terminal bus connection (optional) SIMATIC PCS 7 redundant terminal bus adapter package (6ES7 6520XX01-1XF1) Additional provision if necessary (installation free of charge). Slots 3 x PCle Gen2 x4 (mech. X8) 4 x PCle Gen3 x8 (of which 1 x reserved for RAID) The scope of delivery includes an image DVD for disaster recovery. Note: The Premium Server for SIMATIC PCS 7 can be used as the basic server system for SIMATIC PCS 7 V8.0 or 7.1. The preinstalled Microsoft Windows Server 2008 R2 SP1 (Standard Edition) operating system is tailored to the requirements of the SIMATIC PCS 7 V8.0 system software. ■ Benefits 7 7 7 7 7 7 High performance High availability through fully redundant hardware configuration High data security due to fast, failsafe RAID1 system SIMATIC PCS 7 conformity minimizes project risks and commissioning costs Supplied restore DVD enables the original configuration to be quickly restored in the event of a failure Flexible for expansions, project-specific special configuration on request 4/4 Siemens ST PCS7 AO · 2013 1 x PCle Gen2 x8 (mech. 16) 2 x PCle Gen3 x16 Power supply Redundant, hot-plug power supplies and fans including monitoring Rack integration Simple 19" rack integration; including telescopic rails Drives 1 x DVD-RW supermulti 1.6" SATA drive Connections 10 x USB 2.0 connections; 1 x serial RS 232 Default language English Operator control Without keyboard or mouse; without monitor Warranty conditions 3 years, EMEA Optionally extendable to 5 years, EMEA Dimensions and weight Rack dimensions (W x H x D in mm) 482.6 (bezel)/448 (body) x 736 x 177 Weight Approx. 35 kg © Siemens AG 2013 Operator control and monitoring Premium Server for SIMATIC PCS 7 ■ Technical specifications (continued) Electrical connection values Power supply configuration 2 x 800 W hot plug power supply with three redundant hot plug dual fans Max. power supply output power 2 x 800 W Rated voltage range 100 ... 240 V Rated frequency range 50 ... 60 Hz Heat dissipation 3852 kJ/h (3651 BTU/h) Ambient conditions (temperature/relative humidity) Operation Product safety • Germany • Europe • Global 10 ... 35 °C, 10 ... 85% (no condensation) GS CE Class A CB RoHS (Restriction of Hazardous Substances, limitation of use of hazardous substances) WEEE, disposal of waste electrical and electronic equipment Compliance with directives Electromagnetic compatibility (EMC) Conformity procedures (Class A) • Australia, New Zealand • Japan, Taiwan • USA, Canada In general, the safety requirements all European countries and North America maintained. C-Tick VCCI / CNS 13438 class A - planned CSAc/us/FCC class A ■ Selection and ordering data Premium Server for SIMATIC PCS 7, standard capacity Order No. 9AE4 510-2PC70 • Rack housing 4 HU • 2 x Intel Xeon E5-2640 6C/12T 2.50 GHz 15 MB • 8 GB RAM • Hard disk system (RAID1) SAS 300 GB 10K hot plug 2.5", 2 x 10/ 100/1000-TP-LAN • Redundant power supply/fan • Windows Server 2008 R2 SP1 Standard 64-bit, multi-language operating system, including 5 CALs 4 Premium Server for SIMATIC PCS 7, extended capacity Recommended for use as Central Archive Server (CAS) • Rack housing 4 HU • 2 x Intel Xeon E5-2640 6C/12T 2.50 GHz 15 MB • 8 GB RAM • Hard disk system (RAID5) SAS 300 GB 10K hot plug 2.5" incl. 1 x hot spare HDD • 2 x 10/100/1000-TP-LAN • Redundant power supply/fan • Windows Server 2008 R2 SP1 Standard 64-bit, multi-language operating system, including 5 CALs 9AE4 510-2PC71 Premium Server for SIMATIC PCS 7, Process Historian Recommended for use as PCS 7 V8 Process Historian server (PH) • Rack housing 4 HU • 1 x Intel Xeon E5990 6C/12T 3.46 GHz 12 MB • 48 GB RAM • Hard disk system (RAID5) SAS 300/900 GB 10K hot plug 2.5" 2 x 10/100/1000-TP-LAN • Redundant power supply/fan • Windows Server 2008 R2 SP1 Standard 64-bit, multi-language operating system, including 5 CALs 9AE4 510-2PC72 ■ More information Siemens AG Industry Sector Customer Services Division Value Services Karlsruhe Tel.: +49 721 595 2350 Fax: +49 721 595 6630 E-mail: [email protected] Siemens ST PCS7 AO · 2013 4/5 © Siemens AG 2013 Operator control and monitoring Large-screen systems for control rooms ■ Overview PCS 7 Add-on fit for SIMATIC PCS 7 V8 Apart from the type and scope of the presentation of information, the architecture of the control center is a major criterion influencing the decision of the control system customer. The full specification of a control center includes recommendations relating to screen, image encoder technology, installation, lighting, air conditioning and software. 4 As a reliable partner for the user-friendly configuration of control centers with large-screen systems, Barco Control Rooms pays particular attention to the balance between functional, ergonomic and economic aspects. Control rooms with large-screen systems based on backprojection and LCD systems from Barco Control Rooms are ergonomic and functional. They provide an exceptional working atmosphere, and impressively represent the plant within the company and toward customers and visitors. Note: Large-screen systems from Barco Control Rooms can be used together with SIMATIC PCS 7 V7 and V8. ■ Function The many years of experience of Barco Control Rooms in the development of back-projection and LCD systems is reflected in the comprehensive range of products based on state-of-the-art technologies. The range includes the following standard products: Screen diagonal 1) System OVL-508, 708, 808 50", 70", 80" OVL-515, 715, 815 MVL-615, 6715, 815 60", 67", 80" Type x08 = resolution XGA (1024 x 768 pixels) Type x15 = resolution SXGA+ (1400 x 1050 pixels) 16.7 million colors, LED lighting, automatic brightness and color adjustment Digital interface (DVI-D)²) and web-based service interface Single-chip DLP technology with LED OverView LED series (16:9) 50", 70" OL-521, 721 Technical specifications Single-chip DLP technology OverView LED series (4:3) OL-510, 710 Type x21 = Full HD resolution (1920 x 1080 pixels) type x10 = HD Ready resolution (1360 x 768 pixels) 16.7 million colors, LED lighting, automatic brightness and color adjustment OLF-521, 721 MVL-621, 721 50", 70" NSL-4621, NSL-5521 46", 55" Digital interface (DVI-D)²) and web-based service interface OLF: Front access, small space requirements LCD, near seamless, 5.7 mm, LED backlight technology Full HD resolution (1920 x 1080 pixels) RS 232 service interface LDX-46, LDX-55 46", 55" LCD, LED backlight technology Full HD resolution (1920 x 1080 pixels) RS 232 service interface 1) Customized systems with other screen diagonals can also be implemented. 2) An interface for an analog port (VGA) is available as option. 4/6 Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Operator control and monitoring Large-screen systems for control rooms ■ Function (continued) All large-screen systems have a modular structure. Several screens can be combined into a panel of any size. The panel is thus a large monitor on which graphic objects and information can be displayed and moved beyond the limits of the individual screens. The image sources offer exceptional brightness and contrast values as well as sharp and distortion-free pictures. The automatic brightness and color adjustment of all modules of an LED large panel by means of Sense6 technology guarantees a uniform and ergonomic image quality. ■ More information Barco Control Rooms GmbH Greschbachstr. 5a D-76229 Karlsruhe Germany Germany (Central Europe) Tel.: +49 721 6201131 E-mail: [email protected] Belgium (Western Europe) All back-projection and LCD systems have standardized interfaces for the display of computer applications, video and monitor signals. They can be connected directly to the SIMATIC PCS 7 operator stations without any additional configuration (plug & play). Tel.: +32 5626 2009 E-mail: [email protected] The back-projection and LCD systems from Barco Control Rooms are optimized for low-maintenance 24/7 operation. For example, the O(V)L series can operate for 5 years without maintenance. Brazil (South America) 4 USA (North America) Tel.: +1 678 4758000 Tel.: +55 11 3842-1656 E-mail: [email protected] Dubai UAE (Middle East) Tel.: +971 4 375 6803 Asia Beijing Tel.: +86 139 0136 7382 Singapore Tel.: +65 62437610 Japan Tel.: +81 3 5762 8727 Additional information is available on the Internet at: www.barcocontrolrooms.com Siemens ST PCS7 AO · 2013 4/7 © Siemens AG 2013 Operator control and monitoring KVM extender: Operator channel extensions ■ Overview PCS 7 Add-on fit for SIMATIC PCS 7 V8 ■ Application With the aid of the KVM extenders, the operating personnel can operate and monitor the process from the control room, while the computers are located in a secure and air-conditioned technology room separate from the operator panels. Thanks to the separate installation of the computers, maintenance work by the IT administrators can be carried out centrally in the technology room. Another advantage: The work carried out by operators in the control room is not interfered with or interrupted by servicing. 4 Concentrated working is thus possible without fan noise or the dissipated heat of computers. ■ Design Using the Keyboard Video Mouse extenders from Guntermann & Drunck GmbH, you can extend the operating channel of the SIMATIC PCS 7 Industrial Workstation. It is then possible to spatially separate the display and operation components from the computer, and position operator stations up to 10 000 m away from the computer. KVM extender FIBREVision, transmitter unit (top) and receiver unit (bottom), rear view The KVM extenders transfer the following computer signals: • Video (single or multiple) • Keyboard, mouse (PS/2 and USB) • USB 1.1 and USB 2.0 (optional) • Audio (optional) • RS 232 (optional) • Remote power (optional) The KVM extenders DVIVision, CATVision, LwLVision, FIBREVision, DL-Compact, and DL-Vision each consist of a transmitter unit and a receiver unit in desktop or 19" design which are connected to one another by means of a CAT cable (5/6/7) or a fiber-optic cable. They are independent of the system platform and the operating system. An operator station can be set up on the transmitter and receiver (exception: KVM extender DL-Compact: an operator station can only be used on this device on the receive side). You can select the following product versions depending on requirements (further differences can be found under "Technical specifications"): The KVM extender DL-Vision has a redundant power supply. With the exception of the DL-Compact, the other KVM extenders are also optionally available with a redundant power supply. If a power supply fails, the redundant supply unit immediately takes over. The connection to the computer is thus retained without interruption. Product version Transmission of VGA Max. distance DVI dual link n DVIVision CATVision n LwLVision n FIBREVision DVI single link 140 m 300 m n 10 000 m n 10 000 m DL-Compact n 400 m DL-Vision n 10 000 m Note: All KVM extenders can be used together with SIMATIC PCS 7 V7 und V8. 4/8 Siemens ST PCS7 AO · 2013 The standard interfaces are used for the computer connection. Neither software settings nor computer adjustments are necessary. The DL-Vision has two network connections, a Web interface, and a monitoring function. These enable simple configuration as well as monitoring and reporting of values per Web interface. The KVM extenders DL-Vision, DVIVision, and FIBREVision are provided with a screen freeze function. If a monitor loses the video signal or if there is a problem with the graphic controller of the remote computer, the screen freeze function freezes the last displayed image. © Siemens AG 2013 Operator control and monitoring KVM extender: Operator channel extensions ■ Design (continued) With the exception of the DL-Compact, all KVM extenders support multi-channel operation with 2 (LwLVision) or up to 4 video signals. Depending on the multi-channel graphic controller of the computer and the selected KVM extender, it is possible to implement multi-monitor operator stations with up to 4 screens each. By means of an KVM switch, local maintenance by an administrator can be centralized in the control room. KVM extender DL-Vision, rear view of receiver unit 4 ■ Technical specifications Specification DVIVision CATVision LwLVision FIBREVision DL-Vision DL-Compact Local operator station (console) Yes Yes Yes Yes Yes No Maximum transmission dis- 140 tance in m 300 550/10 000 550/10 000 10 000 m using sin- 400 gle-mode fibers 300 m using multimode fibers Transmission medium Cable CAT5e and higher CAT5, CAT6, CAT7 cable Multi-mode/singlemode fibers Multi-mode/singlemode fibers Multi-mode/singlemode fibers Multi-mode fibers Signals always possible for Keyboard, video, mouse transmission Keyboard, video, mouse Keyboard, video, mouse Keyboard, video, mouse Keyboard, video, mouse, audio, RS 232 Keyboard, video, mouse RS 232/audio and Additional signals which can be transmitted (optio- USB 1.1 nal) RS 232, audio, USB 1.1 and USB 2.0 RS 232, audio (inclu- RS 232, audio and ded) and USB 1.1 USB 1.1 USB 2.0 – Keyboard/ mouse format PS/2 and USB (also PS/2 and USB (also PS/2 and USB (also PS/2 and USB (also PS/2 and USB (also PS/2 and USB (also mixed mode) mixed mode) mixed mode) mixed mode) mixed mode) mixed mode) Video • Input Digital (single link) Analog • Number of channels Analog or digital Digital (single link) Digital (dual link) Digital (dual link) (single link) Analog or digital Analog Analog or digital Analog or digital Digital Digital 1920 x 1200 at 60 Hz 1920 x 1440 at 75 Hz 1280 x 1024 at 1920 x 1200 at 60 Hz 2560 x 1600 at 60 Hz 2560 x 1600 at (depending on dis- 75 Hz, 2048 x 2048 at 60 Hz 60 Hz, tance) 1920 x 1200 at 60 Hz 2048 x 2048 at 60 Hz Up to 4 Up to 4 Up to 2 Up to 4 Up to 4 1 Expandability With KVM switch With KVM switch • Output • Maximum resolution With KVM switch With KVM switch With KVM switch With KVM switch Note: Depending on the cable medium and video signal used, the systems feature automatic image optimization mechanisms. ■ More information Guntermann & Drunck GmbH Systementwicklung Dortmunder Str. 4a 57234 Wilnsdorf Germany Tel.: +49 27 39-89 01-100 Fax: +49 27 39-89 01-120 E-mail: [email protected] Additional information is available on the Internet at: www.gdsys.de/ Siemens ST PCS7 AO · 2013 4/9 © Siemens AG 2013 Operator control and monitoring KVM matrix switches: Flexible operator station administration ■ Overview PCS 7 Add-on DVI KVM matrix switches fit for SIMATIC PCS 7 V8 The DVI KVM matrix switches DVICenter and ControlCenterDigital switch the following signals: • Video (DVI single link) • Keyboard and mouse (USB & PS/2) • Audio bidirectional • RS 232 & USB 2.0 A functional system comprises at least the following elements: • 1 x central unit (DVICenter) or central unit + I/O cards (ControlCenter-Digital) • 1 x server unit (DVI-CPU) • 1 x operator station unit (DVI-CON) • 1 x transmission cable (CAT or fiber-optic cable) per port 4 The operator stations are connected in the case of DVICenter and ControlCenter-Digital by means of the operator station units DVI-CON (user consoles). DVICenter and ControlCenter-Digital access the external server interfaces via the DVI-CPU server unitss (connection dongle). Both the ControlCenter-Digital and the DVICenter can be cascaded or stacked. Large installations with up to 4 000 servers can be implemented in this manner. VGA KVM matrix switches By using the compact KVM matrix switches, you can access n servers of a system from m different operator stations locally and/or remotely. Remote access can be carried out in different manners: • by LAN (Local Area Network) • by WAN (Wide Area Network) "over IP" • 1:1 via CAT cable (distances up to 300 m) and/or fiber-optic cable (distances up to 10 000 m) The product range offered is classified as follows depending on the video signal: • DVI KVM matrix switches - DVICenter DP64 (up to 63/1 or 1/63 operator stations/server), DP32 (up to 31/1 or 1/31), and DP16 (up to 15/1 or 1/15) - ControlCenter-Digital, designed with 288, 160 or 80 dynamic ports (DP), can be configured as desired as operator station connection or server connection • VGA KVM matrix switches - CATCenter NEO 4/32, 8/32 or 16/64 (operator stations/servers) - CompactCenter X2: 2/16 (operator stations/servers) The data of these products can be found under "Technical specifications". The KVM matrix switches DVICenter, CATCenter NEO, and CompactCenter X2 communicate via CAT cables (types 5, 6, 7). When using the modular ControlCenter-Digital, communication between operator station and server can take place via CAT cables or fiber-optic cables (individually or mixed). 4/10 Siemens ST PCS7 AO · 2013 The VGA KVM matrix switches CATCenter NEO and CompactCenter X2 switch the following signals: • VGA • Keyboard and mouse (USB & PS/2) • Audio, selectable (only CATCenter NEO) A functional system comprises at least the following elements: • 1 x central unit (CATCenter NEO or CompactCenter X2) • 1 x server unit (CATpro2) • 1 x operator station unit (UCON), exception: CompactCenter X2 • 2 x transmission cable (CAT cable) The operator stations are connected to the CATCenter NEO via user console modules (UCON). With the CompactCenter X2, the operator station is integrated in the KVM matrix switch. Both KVM matrix switches access the external server interfaces via the DVI-CPU server units (connection dongle). Whereas the CompactCenter X2 is used exclusively in standalone mode, the CATCenter NEO products can be combined with each other and expanded up to 2048 servers and 128 operator stations. Note: All KVM matrix switches can be used together with SIMATIC PCS 7 V7 and V8. © Siemens AG 2013 Operator control and monitoring KVM matrix switches: Flexible operator station administration ■ Design DVI KVM matrix switch DVICenter DVI KVM matrix switch ControlCenter-Digital 4 DVI KVM matrix switch DVICenter 1: DVICenter, 2: DVI-CON, 3: DVI-CPU DVI KVM matrix switch ControlCenter-Digital 1: ControlCenter-Digital, 2: DVI-CON, 3: DVI-CPU The compact DVI-KVM matrix switch DVICenter enables independent operation of n servers from m operator stations consisting of monitor, keyboard, and mouse. The modular and highly flexible DVI-KVM matrix switch ControlCenter-Digital enables independent operation of n servers from m operator stations consisting of monitor, keyboard, and mouse. It is particularly suitable for large plants with many servers. Thanks to the dynamic port technology, each individual DVICenter port can be configured either as a server unit connection or an operator station unit connection. The DVICenter is available in three graded versions: DP16, DP32, and DP64. In stand-alone mode, applications can be configured with up to 16 (DP16), 32 (DP32) or 64 (DP64) terminals (server or operator station units). The number of terminals can be greatly extended by cascading the devices, enabling implementation of large installations with hundreds of servers. On the other hand, stacking of the devices (connection of up to 10 DVICenter via the bus port) allows extension of the switchable signals of a computer or operator station. Typical applications for the DVICenter are large plants with many servers which have to be controlled from several distributed operator stations. Thanks to the dynamic port technology, all ports can be used either as a server unit connection or an operator station unit connection. The ControlCenter-Digital automatically detects whether a server unit or operator station unit is connected. Depending on the configuration level, up to 80, 160 or 288 ports are available for operator stations or servers. The configuration with 288 ports therefore allows 1 to 287 servers to be operated and monitored from 287 to 1 simultaneous operator stations. Even larger installations are possible by cascading and/or stacking. The modular design can be flexibly adapted and expanded depending on the project requirements, since the controller, switch and I/O cards, as well as power supplies and fan modules, can be replaced rapidly and simply thanks to hot plugging/swapping. Highlights • High flexibility thanks to complete modularity of system components • Triple redundant power supply • Hot swapping of individual components DVICenter modules ControlCenter-Digital with 288 ports Siemens ST PCS7 AO · 2013 4/11 © Siemens AG 2013 Operator control and monitoring KVM matrix switches: Flexible operator station administration ■ Design (continued) VGA-KVM matrix switch system CATCenter NEO VGA KVM matrix switch CompactCenter X2 Architecture with KVM matrix switch CATCenter NEO (schematic representation) 1: CATCenter NEO, 2: UCON, 3: UCON-IP-NEO (+ local workstation), 4: CATpro2, 5: IP client Architecture with KVM matrix switch CompactCenter X2 (schematic representation) 1: CompactCenter X2, 2: CAT connection (to CATpro2), 3: local workstation, 4: IP workstation The VGA KVM matrix switch CATCenter NEO switches the VGA, keyboard, mouse, and audio signals. It is designed for larger systems where the servers are accessed from several operator stations. The operator stations can also be distributed between different locations. The VGA KVM matrix switch CompactCenter X2 switches the VGA, keyboard, and mouse signals. It can be used for effective administration and simultaneous operation of up to 16 servers from two operator stations: • 1 x analog, directly on the CompactCenter • 1 x by LAN/WAN over IP 4 In addition to the KVM matrix switch (central unit), a functional system also comprises the additional modules required for connecting the servers and operator stations: • Central unit: KVM matrix switch CATCenter NEO, versions for 4/32, 8/32 or 16/64 (operator stations/servers) • Operator station unit: User console UCON • Server unit: Server connection dongle CATpro2 The central administration of individual (distributed) plant sections is a possible application example of an operator station connected by LAN/WAN over IP. In addition to the KVM matrix switch (central unit), a functional system also comprises a module for connecting the server: • Central unit: KVM matrix switch CompactCenter X2 with 2 integrated operator station connections • Server unit: Server connection dongle CATpro2, versions CATCenter NEO modules The KVM matrix switch CATCenter NEO can be configured per Web interface. A network connection is integrated in all CATCenter NEO model versions (SNMP, Syslog, monitoring functionality, configuration). 4/12 Siemens ST PCS7 AO · 2013 CompactCenter X2 modules © Siemens AG 2013 Operator control and monitoring KVM matrix switches: Flexible operator station administration ■ Technical specifications Specification DVICenter Number of consoles or operator stations Min. 1 to max. 63 + cascading/ Min. 1 to max. 287 + cascading/ 4/8/16 (via user console modu- 2 (1 x local, analog; 1 x by LAN/ stacking stacking les UCON) WAN over IP) Number of servers Min. 1 to max. 63 + cascading/ Min. 1 to max. 287 + cascading/ 32/32/64 stacking stacking 16 Standard DVI interface Standard VGA interface Video • Port • Max. resolution - Analog - Digital (over IP) • • • • Bandwidth H/V sync Color depth Image optimization Keyboard/mouse • Interfaces in direction: Server • Interfaces in direction: Operator station ControlCenter-Digital Standard DVI interface CATCenter NEO (4, 8, 16) Standard VGA interface CompactCenter X2 1920 x 1440 at 60 Hz 1920 x 1440 at 60 Hz DVI single link up to 1920 x 1200 DVI single link up to 1920 x 1200 1920 x 1200 at 60 Hz in 1600 x 1200 at 60 Hz in at 60 Hz at 60 Hz accordance with VESA CVT-RB accordance with VESA DMT or 1920 x 1200 at 60 Hz in accordance with VESA CVT-RB Up to 165 MHz Up to 250 MHz Up to 250 MHz Up to 250 MHz 50 ... 180 kHz, 30 ... 130 Hz 50 ... 180 kHz, 30 ... 130 Hz 50 ... 180 kHz, 30 ... 130 Hz 50 ... 180 kHz, 30 ... 130 Hz 24 bit digital 24 bit digital 32 bit analog, 8 bit digital 32 bit analog, 8 bit digital Automatic video setting Automatic video setting Automatic video setting, indivi- Automatic video setting, individually adjustable dually adjustable PS/2, USB PS/2, USB PS/2, USB, SUN-USB, VT100 PS/2, USB, SUN-USB, VT100 PS/2, USB PS/2, USB PS/2, USB, SUN-USB PS/2, USB, SUN-USB Bidirectional transmission of ste- Transmission of audio signals reo audio signals 22 kHz, sampling rate 96 kHz 20 kHz, sampling rate 44 kHz 24 bit digital 24 bit - • Bandwidth • Resolution Bidirectional transmission of audio signals 22 kHz, sampling rate 96 kHz 24 bit digital Construction type Compact Modular Compact Audio Compact - ■ More information Guntermann & Drunck GmbH Systementwicklung Dortmunder Str. 4a 57234 Wilnsdorf Germany Additional information is available on the Internet at: Tel.: +49 27 39-89 01-100 Fax: +49 27 39-89 01-120 www.gdsys.de/produkte/kvm-matrixswitches/ dvi-kvm-matrixswitches/dvicenter-system E-mail: [email protected] Detailed information on the ControlCenter-Digital and its components is available at: www.gdsys.de Detailed information on the DVICenter and its components is available at: www.controlcenter-digital.com Detailed information on the CATCenter NEO and its components is available at: www.gdsys.de/CATCenter_NEO_System.309.0.html Detailed information on the CompactCenter X2 and its components is available at: www.gdsys.de/CompactCenter.308.0.html Siemens ST PCS7 AO · 2013 4/13 4 © Siemens AG 2013 Operator control and monitoring Visor: Video technology for process monitoring ■ Overview ■ Function PCS 7 Add-on Any analog cameras 4 Real-time for all channels fit for SIMATIC PCS 7 V8 The VISOR 9000 video server works in real-time, i.e. it is able to record up to 25 images per second for each video channel. Image recording can be carried out time-based, eventcontrolled or also permanently. Web cameras Special features: • Digital saving and transmission of video and audio signals together with multi-standard compression and state-of-the-art image analysis algorithms • Video management functionality based on user-programmable, internal logic control • Redundant power supply expansion and internal S-ATA-RAID expansion possible Dome camera Max. 32 cameras/ video servers Two-wire or fiber-optic cable Event control Switch Alarm Ethernet The live video images are displayed on the SIMATIC PCS 7 operator station as a continuous image and/or dependent on a request or controlled by a particular event. ISDN Web cameras Web cameras which can be integrated in a network are available as color or black-and-white devices with integrated PTZ (pan/tilt/ zoom) function. SIMATIC PCS 7 operator system Workstation G_PCS7_XX_00016 LAN Video technology can make a highly versatile contribution toward rationalization of production processes. Remote from the process, you are able to view important process sequences, evaluate the actual product state, direct the flow of goods, check areas which are difficult or even impossible to access, and much more. The use of video technology in process automation permits, for example: • Prevention of production faults and waste • Optimization of energy costs for combustion processes • Saving of personnel costs The live video data from web cameras or analog cameras can be integrated extremely simply into the SIMATIC PCS 7 operator system using the VISOR products from ASE AG. The VISOR video server is configured using its IP address, either with ASE software or an Internet browser. Otherwise, no additional settings are necessary. Note: VISOR video technology can be used together with SIMATIC PCS 7 V7 and V8. ■ More information ASE AG Lusshardtstrasse 6 76646 Bruchsal Germany Tel.: +49 7251 93259-0 Fax: +49 7251 93259-99 E-mail: [email protected] Additional information is available on the Internet at: www.ase-ag.eu 4/14 Siemens ST PCS7 AO · 2013 VisorX: The VisorX software can be used to directly integrate video signals from web cameras into the SIMATIC PCS 7 process control system. Integration is possible through Windows ActiveX or Windows Dot.Net Assembly. Analog cameras The image information recorded by up to 32 analog cameras is digitized in the VISOR video server, saved in compressed form, and transferred to the SIMATIC PCS 7 process control system via an Ethernet interface. Infrared cameras Infrared cameras for recording of thermal images are particularly suitable for monitoring, evaluating and optimizing combustion processes, for determining temperature distributions, or for fire protection. Camera control Cameras with PTZ (Pan/Tilt/Zoom) function or dome cameras can be controlled from any authorized workstation in the network using a mouse and keyboard. Cascade option As many as 32 cameras can be connected to each VISOR video server. The number of cameras used can be extended as desired by cascading video servers. History memory The history memory enables precise analysis of a particular event by analyzing it in the long-term archive. Extreme ambient conditions When combined with a wide range of enclosures, cameras can be used in hazardous areas (certified according to ATEX), in offshore applications, or in furnaces. © Siemens AG 2013 Operator control and monitoring SIMATIC HMI Thin Client Ex ■ Overview ■ Technical specifications General features Design Thin Client built-in unit, available in protective enclosure as an option Front 15", 19", and 15" sunlight readable display Operation Touch with 8 function keys MTBF backlight 50 000 h Operating system Closed system on Windows XP Embedded basis Mass storage Integrated Power supply 24 V DC, max. 2.1 A (19") 4 Interfaces SIMATIC HMI Thin Client Ex with international approvals for operation and monitoring in hazardous areas. ■ Application The SIMATIC HMI Thin Client Ex is designed for use as an operator station for terminal and client applications in hazardous areas, and in particular for applications for which the performance of the SIMATIC HMI Panel PC Ex is insufficient, or when the server is located in a protected area of the plant. The widelyused RDP and Real VNC protocols are supported. Together with the digital KVM Box, the device functions as a flexible monitor with touch functionality for PCs e.g. in control rooms. Ethernet 100 Mbit Ex e, or alternatively fiber-optics 100 Mbit (SC) Ex op is USB 2.0 2 x Ex i, 2 x Ex e (Zone 1) or 2 x Ex nA (Zone 2) Serial 1 x RS232 or 1 x RS422/485 Ambient conditions Degree of protection IP66 at front, IP65 at rear, IP66 in protective enclosure Ambient temperature during operation -20 °C ... +50 °C, cold start -10 °C, with opt. additional heating down to -30 °C Relative humidity during operation 90 % at 40 °C, no condensation Approvals/directives Devices in version "Zone 1" II 2 (2) G Ex d e mb ib [ib] [op is] IIC T4 II 2 D Ex tD A21 IP65 T90 °C DNV (marine engineering), GOST-R Devices in version "Zone 2" II 3 (3) G Ex d e mb nA nL [nL] [op is] IIC T4 II 3 (2) G Ex d e mb nA nL [ib] [op is] IIC T4 II 3 (2) D Ex tD A22 IP65 [ibD] T90°C, GOST-R Protocols RDP, RealVNC Digital KVM switch Input: DVI / VGA, PS2 / USB, output: RJ45 (IP network) ■ Integration Integrated interfaces with SIMATIC HMI Thin Client Ex: • 10/100 Mbit 100 base TX (Ex e) or 100 base FX (Ex op is) network • 1 x RS232 or 1 x RS422/485 • 4 x USB 2.0 (2 x Ex I, 2 x Ex e (version Zone 1) or 2 x Ex nA (version Zone 2)) Dimensions Mounting dimensions (W x H x D) in mm 15": 427.5 x 327.5 x 165 19": 522.5 x 412.5 x 165 Front dimensions in mm 15": 440 x 340 19": 535 x 425 Weight 15": 15 kg, 19": 23 kg Siemens ST PCS7 AO · 2013 4/15 © Siemens AG 2013 Operator control and monitoring SIMATIC HMI Thin Client Ex ■ Selection and ordering data Order No. SIMATIC HMI Thin Client Ex Order No. 6AV7 200- Accessories 0 ■■ 0 0 - ■■ A 0 Design / display size • Zone 2: 15" Touch with function keys • Zone 2: 19" Touch with function keys • Zone 1: 15" Touch with function keys • Zone 1: 19" Touch with function keys Enclosure options (device is delivered already fitted) • without • Stainless steel enclosure for: - Wall mounting - Stand (incl. coupling, 300° rotation possible) - Suspension bracket (incl. coupling, 300° rotation possible) - Support arm (incl. coupling, 300° rotation possible) 6AV7 675-0FX00-0AA0 6AV7 675-0FX10-0AA0 6AV7 675-0FX20-0AA0 6AV7 675-0PX00-0AA0 Ethernet switch A B With FOC 4 x 100 Base Tx, 1 x 100 Base (MTRJ) Fx Ex op is 0 2 3 4 5 External keyboard for enclosure (incl. keyboard housing) • without • QWERTZ keyboard • QWERTY keyboard • AZERTY keyboard • QWERTZ keyboard with trackball • QWERTY keyboard with trackball • AZERTY keyboard with trackball A B C D E F G Further options together with stainless steel enclosure • Breather glands • Heating (requires breather glands) • Handles • Front USB (at bottom) -z A01 -z B01 -z C01 -z D01 ■ Dimensional drawings Legend: j = Control cabinet or enclosure h = Mounting clamp (10 x) All dimensions in mm. For mounting cut-out see technical specifications. 327.5+0.5 165 326 440 G_ST80_XX_00419 i = Clamping frame 340 4 6AV7 675-0EX00-0AA0 USB drive • Intrinsically-safe, 16 GB • Intrinsically-safe, 16 GB with recovery function • Not intrinsically-safe, 16 GB with recovery function A B D E Communication interfaces • 10/100 base Tx, Ex e • 100 base Fx FOC (SC), Ex op is Digital KVM for HMI Thin Client Ex h 426 i 427.5+0.5 j SIMATIC HMI Thin Client Ex 15" 15" touch front Width in mm Height in mm Depth in mm Operating unit 440 340 165 Installation cutout 427.5 ± 0.5 327.5 ± 0.5 - 4/16 Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Operator control and monitoring SIMATIC HMI Thin Client Ex ■ Dimensional drawings (continued) 412.5+0.5 165 4 G_ST80_XX_00420 411 425 535 h 521 i 522.5+0.5 j SIMATIC HMI Thin Client Ex 19" 19" touch front Width in mm Height in mm Depth in mm Operating unit 535 425 165 Installation cutout 522 ± 0.5 412.5 ± 0.5 - ■ More information Additional information is available on the Internet at: www.siemens.com/simatic-hmi-ex Siemens ST PCS7 AO · 2013 4/17 © Siemens AG 2013 Operator control and monitoring Mouse-Trak: Trackball ■ Overview ■ Design PCS 7 Add-on fit for SIMATIC PCS 7 V8 • Mouse-Trak Professional for problem-free continuous use in office environments - B5XXMP-XROHS (PS/2) - B5XUSB-XROHS (USB) • Mouse-Trak Industrial for harsh environmental requirements (see figure) - BMPIND-XROHS (PS/2) - BUSBID-XROHS (USB) ■ More information 4 Chameleon Group GmbH Viersener Straße 172 D-47877 Willich Germany Tel.: +49 2156 3065476 Fax: +49 2156 4989157 E-mail: [email protected] Additional information is available on the Internet at: As an alternative to the standard mouse, the "Mouse-Trak" trackball mouse is offered for operating SIMATIC PCS 7 operator stations. The Mouse-Trak is available in two versions for different applications. The devices are equipped either with a PS/2 or USB interface. Note: Mouse-Trak Professional and Mouse-Trak Industrial are compatible with SIMATIC PCS 7 V7 and V8. 4/18 Siemens ST PCS7 AO · 2013 www.chameleon-group.com © Siemens AG 2013 Operator control and monitoring Device manager for SIMATIC logon ■ Overview PCS 7 Add-on ■ Design fit for SIMATIC PCS 7 V8 SIMATIC Logon Device Manager The device manager for SIMATIC Logon currently supports the connection of the following logon devices: • Siemens Fingerprint Mouse - Logon by fingerprint - Connection via USB port • GECMA Card Reader / Fingerprint Sensor - Specification: II2 G/EEx ib IIC T4 (Ex-Zone) - Hardware connection via RS 232 interface • Interflex card reader - Compatible with chip cards from Profix, Mifare and LEGIC - Hardware connection via RS 232 or USB port • Euchner electronic key system - Compatible with chip cards from Profix, Mifare and LEGIC - Hardware connection via RS 232 or USB or Ethernet interface A free interface of the specified type on the client or on the SIMATIC PCS 7 single station is required for the hardware connection of the respective logon device. ■ Selection and ordering data SIMATIC Logon is a central operator management system integrated into the SIMATIC PCS 7 process control system, which checks the authorization for access to the system components in connection with various logon devices. SIMATIC Logon supports as standard the following devices for identifying the operating personnel: • Keyboard • Smart card readers USB/serial according to Catalog ST PCS 7, Chapter "Industrial Workstation/IPC", Section "Expansion components" • Logon devices which can be operated with a Microsoft device driver for the respective operating system (e.g. on a USB port). The Device Manager for SIMATIC Logon enables various other logon devices that support different identification technologies (biometric features, chip card, electronic key etc.) to be connected to SIMATIC Logon inexpensively. Note: The Device Manager for SIMATIC Logon can be used in combination with SIMATIC PCS 7 V7 and V8. ■ Benefits 7 7 7 7 7 7 No problems with passwords, e.g. forgetting password or password easily accessible Fast logon without any typing errors Greater security thanks to personal smart card or biometric features Existing chip cards can be used, e.g. company identity card Readers of the same type can be used Customer-specific adaptations possible (on request) Device manager for SIMATIC logon for the connection of various logon devices to SIMATIC Logon, e.g. Siemens Fingerprint Mouse, GECMA Card Reader/Fingerprint Sensor, Interflex Card Reader, Euchner Electronic Key System; connection of other devices on request Order No. 9AE4 100-4LD10 Engineering software, software class A, 2 languages (English, German), single license for one installation Delivery package: Certificate of license; software and electronic documentation by online download; CD on request Siemens Fingerprint Mouse with USB port, type C98451-D6200-A4-1 9AE4 100-4LD20 Note: Device Manager for SIMATIC Logon required additionally. ■ More information Siemens AG Industry Sector Customer Services Division Value Services Karlsruhe Tel.: +49 721 595-2350 Fax: +49 721 595-6383 E-mail: [email protected] Siemens ST PCS7 AO · 2013 4/19 4 © Siemens AG 2013 Operator control and monitoring Operator's ToolSet ■ Overview PCS 7 Add-on fit for SIMATIC PCS 7 V8 Products such as OTS shift log and OTS document management system which are present in the Operator’s ToolSet (OTS) family can be used individually or combined together. By means of fast and targeted provision of user-specific information, they permit efficient response without the need for programming knowledge or special know-how. Hence it may be possible to avoid plant failures or reduce downtimes. Development of the OTS products was based on many years' practical experience gained from numerous customer projects in various industries, and considers the demands and requirements of many owners of SIMATIC PCS 7 systems. 4 Note: OTS suite, OTS shift log and OTS document management system can be used together with SIMATIC PCS 7 V7 and V8. ■ Function OTS Info Object OTS curve collector and OTS curve group system – a contribution to plant safety The curve collector is comparable with a shopping basket which can be conveniently filled with up to 10 process tags from different parts of the plant by means of a mouse click in the process image. The values of these process tags can be subsequently displayed in the curve group system. The settings of the process tag, e.g. name or unit of measure, are imported at the same time, and automatically taken into account in the curve display. The Info Object is the interface between the plant objects and various OTS programs. A mouse click on the Info Object opens a menu with the following options: (1) Open object view of shift log (2) Collect archive value (process tag) using the curve collector (3) Add archive value (process tag) to the curve group system (4) Open linked documents The curve group system is used for simple display and management of curve groups. The simultaneous display of curves of various measured values, the fast opening of existing curve groups, and the situation-dependent creation of new curve groups enable operators to recognize any abnormalities or imminent failures earlier and to react accordingly. OTS shift log – advantage through information The clear OTS shift log allows colleagues to be informed simply and rapidly of all events in the system, and also to delegate and track tasks. Plant operators, shift engineers and plant managers can rapidly gain an up-to-date overview of the status of the complete plant on the SIMATIC PCS 7 OS client or on the computer in the office. Recording of the information and instructions directly on the object in the process image, as well as their management, is carried out uniformly throughout the company and independent of the shift. Stored information can be called simply by clicking on the Info Object. The information is therefore always available at the position where it is required – structured in different views, with status ID, in document quality, and for an unlimited time. The OTS shift log is suitable for optimization and simplification of processes, and also takes into account the official requirements. Improved communication, fewer misunderstandings, and reduced paper requirements are additional advantages. 4/20 Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Operator control and monitoring Operator's ToolSet ■ Function (continued) OTS Document Management System – documentation at the right location The OTS document management system (OTS-DMS) is distinguished by its plant-oriented storage of documents. The documents can be called intuitively, i.e. simply by clicking directly on the process object. OTS-DMS finishes with mountains of paper and time-consuming document searches. It allows convenient organization of electronic documents of any type, and makes them easy to find again. The advantages of the central data storage also take effect. All operators access a uniform database. Problems resulting from different versions or time-consuming updating of documents at different storage locations belong to the past. The OTS-DMS can also be executed on computers which do not contain SIMATIC PCS 7 OS software. ■ More information 4 GreyLogix GmbH Conrad-Röntgen-Str. 1 24941 Flensburg Germany Tel.: +49 461 50 54 87-998 Fax: +49 461 50 54 87-100 E-mail: [email protected] Additional information is available on the Internet at: www.operators-toolset.com Siemens ST PCS7 AO · 2013 4/21 © Siemens AG 2013 Operator control and monitoring Notes 4 4/22 Siemens ST PCS7 AO · 2013 5 © Siemens AG 2013 Libraries/blocks/tools 5/2 SIMATIC PCS 7 Industry Library (IL) 5/4 MFL: Modular PCS 7 block library for technological functions 5/5 AS-Interface block library for SIMATIC PCS 7 5/7 Gas analysis library for SIMATIC PCS 7 5/8 Modbus libraries for SIMATIC PCS 7 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Libraries/blocks/tools SIMATIC PCS 7 Industry Library (IL) ■ Overview ■ Design PCS 7 Add-on The SIMATIC PCS 7 Industry Library V8.0 functionality is distributed across two sublibraries which can be installed separately: • Industry Library for PCS 7 • Industry Library for S7 fit for SIMATIC PCS 7 V8 The product structure, however, is geared toward the operational environment in the SIMATIC PCS 7 process control system. As a result, the SIMATIC PCS 7 Industry Library V8.0 is available in the form of an engineering component and a runtime component: • SIMATIC PCS 7 Industry Library Engineering V8.0: Engineering software with engineering license for one engineering station • SIMATIC PCS 7 Industry Library Runtime V8.0: Runtime license for one automation system (SIMATIC PCS 7 automation systems of all designs and S7-300 controllers) SIMATIC PCS 7 Operator Station Plant bus 5 AS 41x with Touch Panel - PCS 7 APL (WinCC flexible) - IL for PCS 7 S7-300 with IL for S7 SIMATIC PCS 7 Touch Panel (WinCC flexible) Package Unit G_PCS7_XX_00328 The SIMATIC PCS 7 Industry Library Engineering V8.0 product component enables you to carry out configuration work on a SIMATIC PCS 7 Engineering Station with both sublibraries. The SIMATIC PCS 7 Industry Library (IL) V8.0 expands the concentrated standard functionality of the SIMATIC PCS 7 V8.0 process control system in the SIMATIC PCS 7 Advanced Process Library (APL) to include technological blocks and faceplates for industry-specific applications. It also supports operator control and monitoring via Touch Panels as well as the integration of SIMATIC S7 package units into SIMATIC PCS 7 applications. At the heart of the SIMATIC PCS 7 Industry Library are several tried-and-tested industry libraries (from fields such as water/ wastewater and building automation), whose blocks now have a modern, APL-style design. Together with the APL, the SIMATIC PCS 7 Industry Library enables harmonized overall solutions with a uniform look and feel for specific control system tasks in many different industries, e.g.: • Chemical industry • Pharmaceutical industry • Water and wastewater • Glass and solar industry • Oil and gas • Food and beverage industry • Minerals and mining It helps accelerate the engineering process, reduce the time-tomarket, and simplify process control. Note: The SIMATIC PCS 7 Industry Library V8.0 can be used together with SIMATIC PCS 7 V8.0. 5/2 Siemens ST PCS7 AO · 2013 The SIMATIC PCS 7 Industry Library Runtime V8.0 product component also allows you to execute blocks from both sublibraries on one automation system. Additionally, please note that when you use SIMATIC PCS 7 Industry Library V8.0 function blocks in SIMATIC PCS 7 automation systems, SIMATIC PCS 7 AS Runtime POs are also booked. ■ Function Industry Library for PCS 7 Sublibrary for the functional expansion of the SIMATIC PCS 7 Advanced Process Library with: • Hierarchical multi-control room operation • Panel interface blocks for APL and IL functions • Analog monitoring of 8 freely selectable limit values • Analog monitoring with additional binary limit value monitoring • Equipment monitoring for up to 16 units • Time switch for up to 8 time intervals • Polyline with faceplate • Setpoint encoder with a variable number of setpoints • Functions for building automation • Simulation blocks • Jump distributor for up to 5 jump destinations • Communication functions © Siemens AG 2013 Libraries/blocks/tools SIMATIC PCS 7 Industry Library (IL) ■ Function (continued) Industry Library for S7 Sublibrary for the configuration and integration of package units that are based on S7-300 controllers with: • Panel interface blocks for IL functions • Analog monitoring of 8 freely selectable limit values • Analog monitoring with additional binary limit value monitoring • Equipment monitoring for up to 8 units • Analog measured value monitoring • Digital measured value monitoring • 3-point actuator (flaps, motors, valves, etc.) • Operator control blocks • Valve control • Motor control (standard motor, with 2 directions of rotation, with variable speed) • Functions for building automation S7-300 package units The blocks and faceplates of the Industry Library for S7 sublibrary integrate package units and distributed systems into a SIMATIC PCS 7 project based on a uniform concept. The function blocks are configured in CFC. Operator control and monitoring for each panel Operator control and monitoring on one panel can be configured with the panel interface blocks of the Industry Library for PCS 7 and Industry Library for S7 sublibraries. Configuration takes place in the CFC with just one connection to the technological block (e.g. the motor). Taking operating rights and hierarchical operating concepts (multi-control room operation) into consideration, the technological function can then be operated both from an operator station and from a Touch Panel. ■ Selection and ordering data Order No. SIMATIC PCS 7 Industry Library Engineering SIMATIC PCS 7 Industry Library Engineering V8.0 Block library for SIMATIC PCS 7 V8.0 and SIMATIC S7 with function blocks and faceplates as well as electronic documentation Engineering software, software class A, 2 languages (English, German), runs with Windows XP Professional 32-bit, Windows 7 Ultimate 32/64-bit, Windows Server 2003 R2 Standard 32-bit, or Windows Server 2008 R2 Standard 64-bit, single license for 1 installation • Engineering license for one engineering station Type of delivery: Toolset DVD, certificate of license • Engineering license for one engineering station combined with runtime license for one automation system Type of delivery: Toolset DVD, 2 certificates of license 6DL5 410-8AX08-0YA0 5 6DL5 410-8AA08-0YA0 SIMATIC PCS 7 Industry Library Runtime SIMATIC PCS 7 Industry Library Runtime V8.0 Language-neutral, single license Type of delivery: Certificate of license • Runtime license for 1 automation system • Runtime license for 30 automation systems 6DL5 410-8AA08-0XL1 6DL5 410-8AB08-0XL1 ■ More information Siemens AG Industry Sector Industry Automation Division Industrial Automation Systems Nuremberg Phone: +49 (911) 895 7222 Fax: +49 (911) 895 7223 E-mail: [email protected] Siemens ST PCS7 AO · 2013 5/3 © Siemens AG 2013 Libraries/blocks/tools MFL: Modular PCS 7 block library for technological functions ■ Overview ■ Design PCS 7 Add-on fit for SIMATIC PCS 7 V8 The MFL includes function blocks for: • Motor, 1 direction of rotation • Motor, 2 directions of rotation • Motor, 2 speeds • Motor FU • Valves • Motor slide • Controller • Dosing • Interlocking module • Analog value monitoring ■ Function 5 Modular blocks In contrast to other libraries, blocks for the implementation of technological functions such as motor, valve, controller etc. are created in MFL from small, fast basic blocks that are graphically interconnected in the CFC and subsequently translated as a block type. Because the graphical sources are also supplied, the user can, if required, very easily adapt the blocks to specific industries or plants without having to develop new basic functions, such as fault philosophy, special control logic or colors. Adaptable faceplates For special applications, blocks can be used several times or different blocks can be combined with one another (4-way valves, motors with special on-site switches etc.) and the faceplates can be correspondingly adapted. The number and functions of the required keys, symbols, and status displays can be programmed in interactive mode. Process tag-oriented faceplates The modular block library MFL enables the maximum performance to be obtained from SIMATIC PCS 7 and allows flexible response to specific technological demands. The blocks offered for technological functions such as motor, valve, controller, etc. are implemented with small, fast basic blocks. These are delivered together with the CFC sources and can therefore be adapted flexibly if there are special requirements. All blocks of a process tag can be visualized and operated by means of a variable faceplate. Operator panels can also be integrated into the SIMATIC PCS 7 system configuration by means of the MFL for on-site operation. Note: The modular block library MFL can be used together with SIMATIC PCS 7 V7 and V8. The MFL is different from libraries in which each block has its own faceplate. In this case a faceplate is not linked rigidly to a structure variable but is adapted dynamically to the called CFC typical. All operable blocks belonging to a process tag can thus be visualized and operated by means of a shared faceplate (see graphic with one motor block, two interlock blocks, current indicator and operating hours counter). Multiple views Blocks may occur several times within one process tag, for example, several locking function blocks for one motor. The faceplate then adapts itself automatically to the conditions, and enables the operator to choose the required block by means of a popup menu (release, automatic etc.). Similarly, the view of a block is not displayed if it is not a component of the process tag. ■ More information Actemium Controlmatic Hegenheimer Str. 4 79576 Weil am Rhein Germany Tel.: +49 7621 6603-0 E-mail: [email protected] Additional information is available on the Internet at: www.actemium.de 5/4 Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Libraries/blocks/tools AS-Interface block library for SIMATIC PCS 7 ■ Overview PCS 7 Add-on ■ Design fit for SIMATIC PCS 7 V8 The AS-Interface block library for SIMATIC PCS 7 contains: • Blocks for access to the I/O data of AS-i slaves • Blocks for diagnostics of the AS-i system • Faceplates for the SIMATIC PCS 7 Maintenance Station • Manual and online help License information The engineering software of the block library AS-Interface for SIMATIC PCS 7 is delivered with 2 licenses, both of which correspond to the single license type: • Engineering license for configuration on one engineering station • Runtime license for execution of AS blocks in one automation system The block library reduces the engineering requirements for interfacing the AS-i to SIMATIC PCS 7 to the positioning and interconnecting of AS-i blocks in the CFC. AS-i diagnostics using the SIMATIC PCS 7 Maintenance Station does not require any additional configuration. Note: The AS-Interface block library can be used in plants with SIMATIC PCS 7 V7.0, V7.1, and V8.0 (for details, see Design, License information). The Engineering Software Migration V7-V8 enables upgrading of an AS-Interface block library for SIMATIC PCS 7 with Engineering Software V7 for use with SIMATIC PCS 7 V8.0. An installation requirement for the Engineering Software Migration V7-V8 is the engineering license for the Engineering Software V7 of the AS-Interface block library for SIMATIC PCS 7 V7.0 or V7.1. The Engineering Software Migration V7-V8 can be installed directly under SIMATIC PCS 7 V8.0. It is not necessary to previously install the Engineering Software V7 of the AS-Interface block library for SIMATIC PCS 7. ■ Function The AS-Interface can be integrated into the process control system in two ways using the AS-Interface block library for SIMATIC PCS 7: • Direct connection on the PROFIBUS DP per DP/AS-i Link Advanced (AS-i single or double master) • Connection via a CP 343-2 or CP 343-2P AS-i master module in an ET 200M remote I/O station on the PROFIBUS DP SIMATIC PCS 7 automation systems PROFIBUS DP/AS-i link Advanced AS-Interface AS-i slave Standard AS-Interface AS-i slave A/B AS-i slave Standard G_PCS7_XX_00228 The AS-Interface can be integrated very simply into the SIMATIC PCS 7 process control system using the AS-Interface block library for SIMATIC PCS 7. Fundamental advantages of the AS-i can then be used: • Easy installation • Low wiring costs when using simple actuators and sensors with SIMATIC PCS 7 An extra license is not required to use the faceplates on the SIMATIC PCS 7 Maintenance Station. CP 343-2 The AS-Interface (AS-i) is an open, cross-vendor bus system for networking simple actuators and sensors (usually binary) in the bottom field area, and allows simultaneous transmission of data and power over one unshielded 2-wire cable. IM 153-2 Engineering in the CFC with the blocks of the AS-Interface library for SIMATIC PCS 7 One runtime license is also additionally required for each further automation system in which the AS blocks are executed. In contrast to the engineering software, the CD with the software and documentation is not included in the scope of delivery of separately ordered runtime licenses. AS-i slave A/B AS-i integration options in SIMATIC PCS 7 Siemens ST PCS7 AO · 2013 5/5 5 © Siemens AG 2013 Libraries/blocks/tools AS-Interface block library for SIMATIC PCS 7 ■ Function (continued) The AS interface operates according to the master/slave principle. The AS-i master module (DP/AS-i Link Advanced, CP 343-2 or CP 343-2P) controls the slaves (sensors/actuators) connected per AS-i cable. Supported AS-i devices AS-i master The AS-i block library for SIMATIC PCS 7 supports the following AS-i masters: • CP 343-2 • CP 343-2P • DP/AS-i Link Advanced single master • DP/AS-i Link Advanced double master 5 AS-i slaves You can use all digital AS-i standard slaves as well as digital AS-i A/B slaves in accordance with the AS-i specification V3.0. Analog AS-i slaves can also be integrated via the DP/AS-i Link Advanced. Diagnostics Diagnostics is carried out using a faceplate in the SIMATIC PCS 7 Maintenance Station. Faults in the AS-i devices are additionally signaled in plain text. ■ More information Siemens AG Industry Sector Control Components and Systems Engineering P.O. Box 2355 D-90713 Fürth/Germany Submit your technical inquiries to: Technical Assistance Tel.: +49 (911) 895-5900 E-mail: [email protected] Support Request: www.siemens.de/industrial-controls/technical-assistance Additional information is available on the Internet at: www.siemens.com/as-interface ■ Selection and ordering data Engineering Software V7 for SIMATIC PCS 7 V7.0/V7.1 AS blocks and faceplates for integrating AS-Interface into SIMATIC PCS 7 with: • Engineering license for 1 engineering station • Runtime license for 1 automation system Delivery package: Certificates of license; software and electronic documentation on CD Engineering Software Migration V7-V8 For upgrading (migrating) an AS-Interface block library with Engineering Software V7 for use with SIMATIC PCS 7 V8.0 3ZS1 635-1XX11-0YE0 AS blocks and faceplates for integrating AS-Interface into SIMATIC PCS 7 V8.0; with license for upgrading an engineering license and all associated runtime licenses of the AS-Interface block library in a SIMATIC PCS 7 system Engineering and runtime software, software class A, 2 languages (English, German), single license for 1 installation Delivery package: Certificates of license; software and electronic documentation on CD Note: An installation requirement is the engineering license for the Engineering Software V7 of the AS-Interface block library for SIMATIC PCS 7 V7.0 or V7.1. The Engineering Software Migration V7-V8 can be installed directly under SIMATIC PCS 7 V8.0. Previous installation of the Engineering Software V7 is not necessary. Runtime license V7 For execution of AS blocks for AS-Interface in an automation system; suitable for AS blocks of the Engineering Software V7 or the Engineering Software Migration V7-V8 Delivery package: Certificate of License Siemens ST PCS7 AO · 2013 3ZS1 635-1XX01-0YA0 Engineering and runtime software, software class A, 2 languages (English, German), single license for 1 installation Runtime software, software class A, 2 languages (English, German), single license for 1 installation 5/6 Order No. AS-Interface block library for SIMATIC PCS 7 3ZS1 635-2XX01-0YB0 © Siemens AG 2013 Libraries/blocks/tools Gas analysis library for SIMATIC PCS 7 ■ Overview PCS 7 Add-on ■ Function fit for SIMATIC PCS 7 V8 Driver blocks The gas analyzers are integrated into the hardware configuration of the SIMATIC PCS 7 process control system using their GSD files. Parameterization of the driver blocks is subsequently carried out corresponding to the device configuration. The driver blocks provide the following functions: • Reading of analyzer values • Starting of autocalibration • Evaluation of device-specific diagnostics • Standard diagnostics • Alarms for analyzer values (alarm limits adjustable on the block) • Simulation Symbols and faceplates The symbols are automatically created and interlinked by the wizard "Generate block symbols". The faceplates can be displayed in various views: • Standard • Maintenance • Configuration • Limits • Trend and alarm ■ Selection and ordering data The driver blocks from the gas analysis library permit integration of the following gas analyzers into the SIMATIC PCS 7 process control system over PROFIBUS DP: • ULTRAMAT 6 and ULTRAMAT 23 • CALOMAT • OXYMAT The driver blocks permit access to the measured values and to the calibration functions of these devices. They can also be used to evaluate and display diagnostics information, and to trigger alarms if necessary. Order No. Gas analysis library for SIMATIC PCS 7 V7 and V8 Gas analysis library for SIMATIC PCS 7 Driver blocks with faceplate for integration of ULTRAMAT 6, ULTRAMAT 23, CALOMAT and OXYMAT gas analyzers in SIMATIC PCS 7 V7 and V8, electronic documentation as well as engineering and runtime license for one automation system each Note: Engineering and runtime software, software class A, 2 languages (English, German), single license for one installation The gas analysis library can be used together with SIMATIC PCS 7 V7 and V8. Delivery package: Software and electronic documentation on CD, engineering and runtime license 9AE4 110-3AB00 ■ More information Siemens AG Industry Sector Customer Services Division Value Services Karlsruhe Tel.: +49 721 595-6380 Fax: +49 721 595-6383 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.de/PCS7_Treiberbausteine Siemens ST PCS7 AO · 2013 5/7 5 © Siemens AG 2013 Libraries/blocks/tools Modbus libraries for SIMATIC PCS 7 ■ Overview ■ Function fit for SIMATIC PCS 7 V8 The Modbus TCP libraries (TCP/IP communication) and the CM101 communication module (MODBUS RTU) with integrated block library (serial communication) allow you to link devices/ systems with Modbus interface to automation systems (controllers) of the SIMATIC PCS 7 process control system. Data can be easily and quickly exchanged between SIMATIC PCS 7 automation systems of the S7-400 series (single or redundant station) and Modbus slaves using the communication blocks of the Modbus TCP libraries. 5 You will be able to connect Modbus RTU slaves to SIMATIC PCS 7 automation systems of the S7-400 series (single or redundant station) with the CM 101 communication module and the block library included in the product package. Modbus communication in the SIMATIC PCS 7 automation system is carried out either via the CP 443-1 communication module (CP 443-1EX20/-1EX30) or a PROFINET interface integrated in the CPU. Note: The Modbus libraries for SIMATIC PCS 7 can be used together with SIMATIC PCS 7 V7 and V8. Modbus TCP/IP Function block libraries Modbus TCP/IP master S7-400 with CP 443-1 Depending on the type of communication, you have to configure a connection to the Modbus slave (Modbus TCP) or the CM 101 (MODBUS RTU) in NetPro via the CP 443-1 communication module in the automation system. Open IE8 communication is also supported via a PROFINET interface integrated in the automation system's CPU. The communication blocks of the Modbus libraries can be positioned in the CFC editor on a Continuous Function Chart. Blocks for reading and writing the different Modbus data types are available. The connection diagnostics function is integrated. A changed connection status, e.g. failure or re-establishment, is signaled in the SIMATIC PCS 7 Operator System by means of an alarm. The redundancy management is also implemented in the communication blocks, e.g. automatic connection switchover. Features • Modbus TCP master or Modbus RTU master functionality • Reading/writing of Modbus variables • Update cycle of < 300 ms is possible (depends on the cycle time, data volume, network load might be much higher) • Support of redundant SIMATIC PCS 7 automation systems and redundant communication partners Modbus serial CM 101 + funcion block library S7-400 with CP 443-1 Modbus TCP/IP master S7-400H with CP 443-1 for redundant controllers Industrial Ethernet (Modbus TCP/IP communication) Modbus Slave 5/8 Modbus Slave Siemens ST PCS7 AO · 2013 Modbus Slave S7-400H with CP 443-1 for redundant controllers CM 101 CM 101 Modbus (serial connection) Modbus Slave ... Modbus Slave Modbus Slave ... Modbus Slave G_PCS7_XX_00259 PCS 7 Add-on © Siemens AG 2013 Libraries/blocks/tools Modbus libraries for SIMATIC PCS 7 ■ Selection and ordering data Order No. Modbus libraries for SIMATIC PCS 7 Modbus TCP master library for SIMATIC PCS 7 standard automation systems Communication blocks for the connection of Modbus TCP slaves to SIMATIC PCS 7 standard automation systems 9AE4 110-1MB10 ■ More information Siemens AG Industry Sector Customer Services Division Value Services Karlsruhe Tel.: +49 721 595-6380 Fax: +49 721 595-6383 Engineering and runtime software, software class A, 2 languages (English, German) E-mail: [email protected] Engineering and Runtime license for a SIMATIC PCS 7 project (the plant must be specified) www.siemens.com/PCS7_drivers Additional information is available on the Internet at: Delivery package: Software and electronic documentation on CD, project license Modbus TCP master library for redundant SIMATIC PCS 7 automation systems Communication blocks for the connection of Modbus TCP slaves to redundant SIMATIC PCS 7 automation systems 5 9AE4 110-1MB20 Engineering and runtime software, software class A, 2 languages (English, German) Engineering and Runtime license for a SIMATIC PCS 7 project (the plant must be specified) Delivery package: Software and electronic documentation on CD, project license Modbus RTU communication module CM 101 including block library CM 101 communication module including block library for the connection of Modbus RTU slaves to SIMATIC PCS 7 standard automation systems 9AE4 110-2MB10 Hardware with engineering and runtime software, software class A, 2 languages (English, German) Delivery package: Hardware, software and electronic documentation on CD Modbus RTU communication module CM101 including block library for redundant SIMATIC PCS 7 automation systems CM 101 communication module including block library for the connection of Modbus RTU slaves to redundant SIMATIC PCS 7 standard automation systems 9AE4 110-2MB20 Hardware with engineering and runtime software, software class A, 2 languages (English, German) Delivery package: Hardware, software and electronic documentation on CD Siemens ST PCS7 AO · 2013 5/9 © Siemens AG 2013 Libraries/blocks/tools Notes 5 5/10 Siemens ST PCS7 AO · 2013 6 © Siemens AG 2013 Distributed I/O on the PROFIBUS 6/2 Function blocks for SIWAREX weighing modules 6/3 Drive ES PCS 7: Function blocks for drives 6/6 SIMOCODE pro function block library for SIMATIC PCS 7 6/8 AddFEM: Redundant I/O module for fast response times 6/12 AirLINE Ex: Pneumatic block for integration into ET 200iSP 6/14 SIMATIC RF: RFID systems 6/15 KSB PumpDrive for SIMATIC PCS 7: Speed control for centrifugal pumps Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Distributed I/O on the PROFIBUS Function blocks for SIWAREX weighing modules ■ Overview ■ Selection and ordering data PCS 7 Add-on fit for SIMATIC PCS 7 V8 Order No. SIWAREX U configuration package consisting of: Function block, faceplate, parameterizing software and manual, 2 languages (English, German), engineering license for SIWAREX U, single license for 1 installation Engineering and runtime software, software class A Delivery package: Software and electronic documentation on CD, engineering license (certificate of license) • For SIMATIC PCS 7 V8.0 • For SIMATIC PCS 7 V7.0 and V7.1 Suitable for 7MH4 950-1AA01 and 7MH4 950-2AA01 7MH4 950-3AK62 7MH4 950-3AK61 SIWAREX FTA configuration package consisting of: 6 Level, proportioning, belt, and loss-in-weight scales in process engineering applications can be quickly and efficiently configured using preconfigured weighing blocks. For the SIMATIC PCS 7 process control system, Siemens offers configuration packages with function blocks for the SIWAREX U, SIWAREX FTA and SIWAREX FTC weighing modules. These weighing blocks are suitable for both standard and fault-tolerant automation systems. In the case of fault-tolerant automation systems, access to the single SIWAREX U/FTA/FTC weighing modules can be made via both subsystems. The weighing blocks supplied with faceplate allow not only the rational integration of the SIWAREX U/FTA/FTC weighing modules into the engineering system, but also the user-friendly operation of the scales by means of the SIMATIC PCS 7 operator stations. Integrated signaling behavior and maintenance functions such as the reading or writing of all scale parameters ensure short standstill times and help to increase the availability. The pixel-graphics engineering with the CFC editor is very clear and easy to use. The use of prepared blocks also eliminates possible sources of errors and reduces the configuration costs. Note: • The function blocks and faceplates for the SIWAREX U/FTA/ FTC weighing modules can be used together with SIMATIC PCS 7 V7 and V8. ■ More information Siemens AG Industry Sector Industry Automation Division Sensors and Communication Karlsruhe Tel.: +49 721 595-2811 Fax: +49 721 595-2901 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.com/siwarex 6/2 Siemens ST PCS7 AO · 2013 Function block, faceplate, parameterizing software and manual, 2 languages (English, German), engineering license for SIWAREX FTA, single license for 1 installation Engineering and runtime software, software class A Delivery package: Software and electronic documentation on CD, engineering license (certificate of license) • For SIMATIC PCS 7 V8.0 • For SIMATIC PCS 7 V7.0 and V7.1 7MH4 900-2AK63 7MH4 900-2AK62 SIWAREX FTC_B configuration package (belt scales) consisting of: Function block, faceplate, parameterizing software and manual, 2 languages (English, German), engineering license for SIWAREX FTC, single license for 1 installation Engineering and runtime software, software class A Delivery package: Software and electronic documentation on CD, engineering license (certificate of license) • For SIMATIC PCS 7 V8.0 • For SIMATIC PCS 7 V7.0 and V7.1 7MH4 900-3AK65 7MH4 900-3AK63 SIWAREX FTC_L configuration package (loss-in-weight scales) consisting of: Function block, faceplate, parameterizing software and manual, 2 languages (English, German), engineering license for SIWAREX FTC, single license for 1 installation Engineering and runtime software, software class A Delivery package: Software and electronic documentation on CD, engineering license (certificate of license) • For SIMATIC PCS 7 V8.0 • For SIMATIC PCS 7 V7.0 and V7.1 7MH4 900-3AK66 7MH4 900-3AK64 © Siemens AG 2013 Distributed I/O on the PROFIBUS Drive ES PCS 7: Function blocks for drives ■ Overview PCS 7 Add-on MASTERDRIVES fit for SIMATIC PCS 7 V8 The MASTERDRIVES series of converters is integrated and modular. The power range extends from 0.55 to 2 300 kW. All standard international line voltages from 200 to 690 V are covered. Four different enclosure versions are available, depending on the application and required performance: Compact Plus, compact device, built-in unit and cabinet unit. MASTERDRIVES converters are also suitable for demanding technological and dynamic applications. MICROMASTER MICROMASTERinverters are standard frequency converters in the power range from 0.12 to 250 kW and can be used in numerous variable-speed drive applications. They are especially suitable for applications with pumps, fans and in conveyor systems. Their large range of line voltages enables them to be used all over the world. SIMOREG DC Master The SIMOREG DC Master is a converter series for controlling DC motors designed for a power range from 6.3 to 2 000 kW and voltages from 400 to 830 V. They are very dynamic and can therefore also be used for demanding technical applications. Faceplates in classic style (left) and APL style (right) SINAMICS Drive ES PCS 7 enables Siemens drives to be controlled via SIMATIC PCS 7 and operated and monitored in the operator station. The Drive ES PCS 7 faceplates make the data relevant to plant operation available on the operator station. SINAMICS is the latest family of drives from Siemens for innovative and future-oriented drive solutions in a wide power range from 0.12 to 1 200 kW with line voltages from 380 to 690 V. Characteristic of the devices from the SINAMICS family which are based on a shared platform concept is their integrated functionality, high degree of flexibility, and facility for combination. Drive ES PCS 7 also provides the drive data relevant to the PCS 7 Asset Management for display on the maintenance station. For parameterization, commissioning and detailed diagnostics of the drive, it is recommendable to also use Drive ES Basic on the engineering station. Note: Drive ES PCS 7 can be used together with SIMATIC PCS 7 V7 and V8. ■ Application Drive ES PCS 7 can integrate the following drive series into SIMATIC PCS 7: • SIMOVERT MASTERDRIVES VC and MC1) • MICROMASTER 3rd1) and 4th generation • SIMOREG DC Master1) • SINAMICS S110/120/150, G130/150, GM150, and GL150 • SINAMICS G120 (with CUs2xx-2 from V7.0 SP1 HF3) 1) Only the library in the classic style is available for these drives. More details on supported CU and firmware versions of the listed drive series can be found in the current information on the associated Drive ES PCS 7 versions under Siemens Service&Support on the Internet. SINAMICS S The SINAMICS S120 drive system is a modular system for highperformance applications in industrial machine construction and plant engineering. A wide range of matched designs, components and functions always allows an optimum solution to be found. SINAMICS S120 can be used to implement powerful single drives and coordinated drives (multi-axis applications) with vector or servo functionality. SINAMICS S150 are designed as cabinet units for variablespeed drives in machine construction and plant engineering. They are particularly suitable for variable-speed drives with high requirements placed on dynamic response and speed accuracy, frequent braking cycles with high braking energies, and four-quadrant operation. SINAMICS G SINAMICS G single drives (AC/AC converters) are specialists for all applications where solid, liquid or gaseous materials have to be moved, transported, pumped or compressed through the use of conveyor belts, pumps, fans and compressors. SINAMICS G120 can be used in all applications as a modular single drive for small to medium powers (0.37 to 90 kW). SINAMICS G130 built-in units and SINAMICS G150 cabinet units for powers from 75 to 800 kW round off the top power range. Siemens ST PCS7 AO · 2013 6/3 6 © Siemens AG 2013 Distributed I/O on the PROFIBUS Drive ES PCS 7: Function blocks for drives ■ Selection and ordering data Order No. Drive ES Basic configuration software Drive ES PCS 7 (classic style) Function blocks and faceplates for integration of SIMOVERT MASTERDRIVES, MICROMASTER 4xx, SIMOREG DC-MASTER, and SINAMICS S/G variable-speed drives into SIMATIC PCS 7; with electronic documentation (5 languages); single license for one engineering station each, comprising: • Engineering license for one engineering station • Runtime license for one automation system Drive ES Basic Software package for easy parameterization, commissioning and diagnostics of Siemens drives using a central engineering station, including routing beyond network boundaries; with electronic documentation (5 languages) Engineering software, software class A, 5 languages (English, German, French, Italian, Spanish), runs with Windows XP Professional 32bit, Windows Server 2003 32-bit, Windows 7 Professional/Enterprise / Ultimate 32/64-bit, Windows Server 2008 Standard 32-bit or 2008 R2 Standard 64-bit Engineering and runtime software, software class A, 5 languages (English, German, French, Italian, Spanish), single license for one installation 6 Order No. Drive ES PCS 7, classic and APL styles Delivery package: Certificates of license; software and electronic documentation on CD • V8.0 for SIMATIC PCS 7 V8.01) Runs with Windows XP Professional 32-bit, Windows Server 2003/ 2003 R2 Standard 32-bit, Windows 7 Enterprise/Ultimate 32/ 64-bit, Windows Server 2008 Standard 32-bit or 2008 R2 Standard 64-bit • V7.1 for SIMATIC PCS 7 V7.11) runs with Windows XP Professional 32-bit, Windows Server 2003/ 2003 R2 Standard 32-bit • V7.0 for SIMATIC PCS 7 V7.01) Runs with Windows XP Professional 32-bit, Windows Server 2003/ 2003 R2 Standard 32-bit Drive ES PCS 7 APL V8.0 for SIMATIC PCS 7 V8.01) Function blocks and faceplates in the style of the PCS 7 Advanced Process Library for integration of SINAMICS S/G and MICROMASTER 4xx variable-speed drives into SIMATIC PCS 7; with electronic documentation (5 languages); single license for one engineering station each, comprising: • Engineering license for one engineering station • Runtime license for one automation system 6SW1 700-8JD00-0AA0 6SW1 700-7JD00-1AA0 6SW1 700-7JD00-0AA0 6SW1 700-8JD01-0AA0 Engineering and runtime software, software class A, 5 languages (English, German, French, Italian, Spanish), runs with Windows XP Professional 32-bit, Windows Server 2003/2003 R2 Standard 32-bit, Windows 7 Enterprise/Ultimate 32/ 64-bit, Windows Server 2008 Standard 32-bit or 2008 R2 Standard 64bit, single license for 1 installation Delivery package: Certificates of license; software and electronic documentation on CD AS runtime license Drive ES PCS 7 for SIMATIC PCS 7 V7.0/ V7.1/V8.0 For processing of function blocks in an automation system 6SW1 700-5JD00-1AC0 Language-independent, single license for one installation Delivery package: Certificate of License 6/4 Siemens ST PCS7 AO · 2013 Delivery package: Certificate of license; software and electronic documentation on DVD • V5.5+SP11) For SIMATIC PCS 7 V7.0, V7.1 and V8.0, single license (floating license for one user) • V5.5+SP11) For SIMATIC PCS 7 V7.0, V7.1 and V8.0, copy license for 60 simultaneous users 6SW1 700-5JA00-5AA0 6SW1 700-5JA00-5AA1 © Siemens AG 2013 Distributed I/O on the PROFIBUS Drive ES PCS 7: Function blocks for drives ■ Ordering data Order No. Upgrades and software update service Drive ES PCS 7 Upgrade (classic style) For single license Delivery package: Written contract • Drive ES PCS 7 (classic or APL style), single license (single license for one installation) • Drive ES Basic configuration software for SIMATIC PCS 7, single license (floating license for one user) • Drive ES Basic configuration software for SIMATIC PCS 7, copy license for 60 simultaneous users Engineering and runtime software, software class A, 5 languages (English, German, French, Italian, Spanish), runs with Windows XP Professional 32-bit, Windows Server 2003/2003 R2 Standard 32-bit, Windows 7 Enterprise/Ultimate 32/ 64-bit, Windows Server 2008 Standard 32-bit or 2008 R2 Standard 64-bit, single license for 1 installation Delivery package: Software and electronic documentation on CD • V6.x/V7.x to V8.01) • V6.x/V7.0 to V7.11) Drive ES Basic Upgrade V5.x to V5.5+SP1 Order No. Software update service Contract for the delivery of all updates/upgrades for 1 year; if not canceled, the contract is automatically extended for one more year 1) 6SW1 700-0JD00-0AB2 6SW1 700-0JA00-0AB2 6SW1 700-0JA00-1AB2 The most recent Service Pack (SP) is always delivered. 6SW1 700-8JD00-0AA4 6SW1 700-7JD00-1AA4 6SW1 700-5JA00-5AA4 6 Engineering software, software class A, 5 languages (English, German, French, Italian, Spanish), runs with Windows XP Professional 32bit, Windows Server 2003 32-bit, Windows 7 Professional/Enterprise / Ultimate 32/64-bit, Windows Server 2008 Standard 32-bit or 2008 R2 Standard 64-bit Delivery package: Software and electronic documentation on DVD ■ More information Siemens AG Industry Sector Drive Technologies Division Motion Control Systems Erlangen Tel.: +49 9131 98-47215 Fax: +49 9131 98-6538 Current product information, FAQs and manuals can also be found at Siemens Product Support under "Drive technology – Selection and engineering tools – DRIVE ES configuration software" Additional information is available on the Internet at: www.siemens.com/drive-es Siemens ST PCS7 AO · 2013 6/5 © Siemens AG 2013 Distributed I/O on the PROFIBUS SIMOCODE pro function block library for SIMATIC PCS 7 ■ Overview ■ Function PCS 7 Add-on fit for SIMATIC PCS 7 V8 The blocks of the SIMOCODE pro library for SIMATIC PCS 7 work together with SIMOCODE pro devices on the PROFIBUS DP which are operated either directly following a PROFIBUS DP master system (standard automation systems) or following a Y-link (fault-tolerant automation systems). Signal processing and technological functions of the blocks are matched to the PCS 7 Standard Library (driver blocks, technological blocks) and are optimally tailored to the functions of the motor management system. Users who previously configured motor feeder circuits using conventional technology by means of signal blocks and motor or valve blocks can now easily switch to the SIMOCODE pro library for SIMATIC PCS 7. The optional measured value and statistics block makes available numerous measured values and statistics information of the SIMOCODE pro motor management system in addition to the comprehensive diagnostics information. 6 The SIMOCODE pro block library for SIMATIC PCS 7 can be used to conveniently integrate the SIMOCODE pro motor management system into the SIMATIC PCS 7 process control system. The library comprises: • Blocks for the automation system (AS) - Driver blocks - Motor blocks - Measured-value and statistics block - Time stamping block • Elements (symbols and faceplates) for operation and monitoring using an operator station (OS) The library supports the CFC function "Generate module driver" which allows system-conformant integration into the SIMATIC PCS 7 driver concept and minimizes the configuration requirements. Using the library blocks, SIMOCODE pro can also be integrated into the asset management of the SIMATIC PCS 7 Maintenance Station. This does not involve any extra configuration effort. Note: The SIMOCODE pro block library for SIMATIC PCS 7 can be used together with SIMATIC PCS 7 V7 or V8 (for details, see Function, License information). ■ Application The blocks of the SIMOCODE pro library for SIMATIC PCS 7 integrate the SIMOCODE pro motor management system into the SIMATIC PCS 7 process control system V7.0, V7.1 or V8.0 over PROFIBUS DP. The SIMOCODE pro motor management system has been designed for use in Motor Control Centers (MCC) in the process industry and power plant engineering. It is particularly suitable for the automation of processes where a plant downtime would result in very high costs. Potential plant downtimes can be efficiently prevented using the detailed operating, service and diagnostics data of SIMOCODE pro. In the event of a fault, you are able to determine and eliminate the cause extremely quickly. 6/6 Siemens ST PCS7 AO · 2013 The time stamp block permits the SIMOCODE pro V time stamping function to be used for SIMATIC PCS 7. It transfers the signals already provided with a time stamp in the device to the automation system, and enters them into the operator station's message list. The library blocks support all SIMOCODE pro control functions: • Overload (OVL) • Direct starter, soft starter (DIR, SOFT) • Reversing starter, soft starter with reversing starter (REV, SOFT) • Star-delta (STAR) • Star-delta with direction reversal (REVS) • Dahlander, pole-changing switch (DAHL, POL) • Dahlander, pole changing switch with direction reversal (DAHL REV, POL REV) • Valve, positioner (VALVE, POS) • Circuit breaker (CB) License information The engineering software of the SIMOCODE pro block library for SIMATIC PCS 7 is delivered with two licenses, both of which correspond to the single license type: • Engineering license for configuration on one engineering station • Runtime license for execution of AS blocks in one automation system One runtime license is also additionally required for each further automation system in which the AS blocks are executed. In contrast to the engineering software, the CD with the software and documentation is not included in the scope of delivery of separately ordered runtime licenses. The Engineering Software Migration V7-V8 enables upgrading of a SIMOCODE pro block library for SIMATIC PCS 7 with Engineering Software V7 for use with SIMATIC PCS 7 V8.0. An installation requirement for the Engineering Software Migration V7-V8 is the engineering license for the Engineering Software V7 of the SIMOCODE pro block library for SIMATIC PCS 7 V7.0 or V7.1. The Engineering Software Migration V7-V8 can be installed directly under SIMATIC PCS 7 V8.0. It is not necessary to previously install the Engineering Software V7 of the SIMOCODE pro block library for SIMATIC PCS 7. © Siemens AG 2013 Distributed I/O on the PROFIBUS SIMOCODE pro function block library for SIMATIC PCS 7 ■ Selection and ordering data Order No. Engineering software AS blocks, symbols, and faceplates for integrating SIMOCODE pro into SIMATIC PCS 7; with: • Engineering license for one engineering station • Runtime license for one automation system P.O. Box 2355 D-90713 Fürth/Germany Submit your technical inquiries to: Technical Assistance Engineering and runtime software, software class A, 3 languages (English, German, French), single license for 1 installation Delivery package: Certificates of license; software and electronic documentation on CD • V7 for SIMATIC PCS 7 V7.0/V7.1 • Upgrade from V6 to V7 Engineering Software Migration V7-V8 For upgrading (migrating) a SIMOCODE pro block library with Engineering Software V7 for use with SIMATIC PCS 7 V8.0 ■ More information Siemens AG Industry Sector Control Components and Systems Engineering SIMOCODE pro function block library for SIMATIC PCS 7 Tel.: +49 (911) 895-5900 E-mail: [email protected] Online support: www.siemens.com/industrial-controls/support Additional information is available on the Internet at: 3UF7 982-0AA10-0 3UF7 982-0AA13-0 www.siemens.com/simocode 3UF7 982-0AA20-0 6 AS blocks, symbols, and faceplates for integrating SIMOCODE pro into SIMATIC PCS 7 V8.0; with license for upgrading an engineering license and all associated runtime licenses of the SIMOCODE pro block library in a SIMATIC PCS 7 system Engineering and runtime software, software class A, 3 languages (English, German, French), single license for 1 installation Delivery package: Certificates of license; software and electronic documentation on CD Note: An installation requirement is the engineering license for the Engineering Software V7 of the SIMOCODE pro block library for SIMATIC PCS 7 V7.0 or V7.1. The Engineering Software Migration V7-V8 can be installed directly under SIMATIC PCS 7 V8.0. Previous installation of the Engineering Software V7 is not necessary. Runtime license V7 For execution of AS blocks for SIMOCODE pro in an automation system; suitable for AS blocks of the Engineering Software V7 or the Engineering Software Migration V7-V8 3UF7 982-0AA11-0 Runtime software, software class A, 3 languages (English, German, French), single license for 1 installation Delivery package: Certificate of License Siemens ST PCS7 AO · 2013 6/7 © Siemens AG 2013 Distributed I/O on the PROFIBUS AddFEM: Redundant I/O module for fast response times ■ Overview ■ Design PCS 7 Add-on fit for SIMATIC PCS 7 V8 Built into a rugged high-grade steel housing, which is in line with the SIMATIC S7 design in terms of dimensions and shape, the AddFEM meets stringent environmental requirements. It is prepared for mounting on DIN rails and for direct mounting with bolts. These installation options support both freestanding construction and installation in cabinets or wall-mounted housings. The connecting elements are protected by a removable hood on which the connector pin assignment of the I/O signals is printed. The functions are set by means of two mode selectors and indicated by 12 LEDs. In accordance with the PLC standard, 2 x 16 LEDs are available in the display panel of the module for signaling the binary I/O signals. ■ Function AddFEM 6 The Front End Module AddFEM is an autonomous unit for the input/output of analog and digital process signals that can be connected with standardized protocols via the PROFIBUS DP fieldbus to the SIMATIC PCS 7 automation system. Its fast response times for signal acquisition and processing should be particularly emphasized. The product range consists of two versions: • AddFEM - 12 analog inputs - 8 analog outputs - 12 digital inputs - 16 digital outputs (can also be configured as digital inputs) - 3 counter/timer inputs (can also be configured as digital inputs) • AddFEM SoE (Sequence of Event) with a preprocessing Front End Function (FEF) - 31 digital inputs with highly exact time tagging. Both product versions can be operated in redundant pairs. The advantage of AddFEM redundancy is that the switchover in this case takes place independent of the automation system (CPU). Note: The AddFEM can be used together with SIMATIC PCS 7 V7.1 and V8.0 including Update 1. ■ Benefits • Modules for operation independently or redundant in pairs • Fast response times for signal acquisition and processing as well as for redundancy switchover (switchover time less than 500 Ps) of the AddFEM • Extended level ranges for analog signals and counters of the AddFEM • Analog and digital areas electrically isolated from one another • Permanently short-circuit-proof analog and digital inputs • Monitoring of all outputs • Outputs can be connected in parallel with other outputs (redundancy, increase in performance) 6/8 Siemens ST PCS7 AO · 2013 The various signal types with AddFEM are distributed across the process connections in such a way that a single module is often sufficient for small applications. Applications with a large quantity framework can be implemented by using several modules. The measuring ranges of the analog inputs and outputs are designed so that no additional signal transducers have to be used. By means of an additional current range of ± 50 mA for the analog outputs, actuators with higher power requirements, e.g. fuel control valves, can also be controlled without additional signal amplifiers. AddFEM SoE (Sequence of Event) with a preprocessing Front End Function (FEF) The Front End Module AddFEM SoE is tailored to the special applications in power plant and process control technology where exact time tagging is required when recording changes in signals, e.g. for archiving the statuses of a power plant for analysis of incidents or for general logging. The AddFEM is synchronized by the GPS time server, and tags the binary signals with an accuracy of 1 ms. The integrated redundancy in 3 levels and the fast, stand-alone switching over guarantee high availability. The module communicates with the automation system over the redundant PROFIBUS DP. The AddFEM SoE requires the AddFEM SoE repeater module for on-site signal distribution, adaptation of the medium (glass FOC to plastic FOC) and signal inversion. © Siemens AG 2013 Distributed I/O on the PROFIBUS AddFEM: Redundant I/O module for fast response times ■ Function (continued) AddFEM SoE repeater module The SoE repeater module can be extended by up to 5 SoE repeater extension modules, and forms a unit together with these. Since the SoE repeater module can be cascaded, up to 5 of such units can be connected in series. SoE repeater module and SoE repeater extension module have no intelligence whatsoever. The logic of the input signal is inverted without changing its timing and connected to the outputs. Large distances have to be covered between the GPS time server and the AddFEM SoE. Therefore glass FOCs are used as the transmission medium between the GPS time server and the SoE repeater module. SoE repeater module, SoE repeater extension module and AddFEM SoE are mounted together in the electronics cabinet. The SoE repeaters are mounted on a rail TH 35 – 7.5 EN 60 715 or TH 35 – 15 EN 60 715. The SoE repeater module is powered with 24 V DC. It supplies the SoE repeater extension module of the unit via a rail bus connector. Up to 6 AddFEM SoE modules can be connected via plastic FOCs to each module. The service interface X1 present on the AddFEM SoE (see graphic) is used as the signal input. 6DL9 902-8AA/-8AB FOC GPS time server 6DL9 900-8AA SoE repeater module 6DL9 901-8AA SoE repeater extension module (up to 5) 6 up to 5 L+ M X1 X1 6DL9 903-8AA/-8AB Plastic FOC AddFEM SoE Siemens ST PCS7 AO · 2013 6/9 © Siemens AG 2013 Distributed I/O on the PROFIBUS AddFEM: Redundant I/O module for fast response times ■ Technical specifications AddFEM/AddFEM SoE Analog outputs (parameterizable) Outputs, total 8 Dimensions (H x W x D) in mm 295 x 75 x 209 Current output range 0 to 20 mA (500 :) Weight 2.8 kg Unipolar 4 to 20 mA (500 :) Supply voltage 24 V DC Current output range ±20 mA (500 :) Bridging of power failures 10 ms (minimum) Bipolar ±50 mA (300 :) Power consumption 20 W Max. error (over the entire temperature range) 0.4% Resolution of A/D converter 13 bit + sign General data PROFIBUS DP interfaces Number of interfaces 2 Baud rate 12 Mbit/s Counting pulse input (parameterizable) Max. cable length of a bus segment 100 m Number of inputs 3 Connectable load per interface 5 V, max. 80 mA Type of input Type 1/2 compliant with IEC 1131-2 Voltage range ±33 V DC Digital inputs (parameterizable) 6 Quantity 12 0 signal level -28 to +3 V Type of input Type 1 compliant with IEC 1131-2 1 signal level +8 to +28 V Voltage range -30 ... +33 V DC Load 1 to 3 k: 0 signal level -30 ... +5 V DC Input frequency (fin) 0 to 20 kHz 1 signal level +11 ... +30 V DC Counter resolution 1/60 000 referred to measured value Galvanic isolation 3 groups with 4 digital inputs each Updating interval 2 ms Display LED in display panel Digital inputs with time tagging: AddFEM SoE Quantity 16 Quantity 31 Type of output Digital semiconductor outputs Time resolution 1 ms Nominal output voltage 24 V DC Approvals/markings Output voltage with 0 signal <1V UL Recognition Mark Output voltage with 1 signal Power supply less 2 V Underwriters Laboratories (UL) compliant with Standard UL 508 File E 85972 Rated output current 500 mA CSA Certification Mark Short-circuit proof Yes Canadian Standard Association (CSA to Standard C22.2 No. 142 File LR 63533) Short-circuit-to-ground monitoring Yes (internal monitoring) CE marking Galvanic isolation Yes (8 outputs each with same reference potential) Compliant with EU directive 89/336/ EEC "Electromagnetic compatibility" Quality assurance According to ISO 9001 Digital outputs (parameterizable) Analog inputs (parameterizable) Inputs, total 12 Current input (fixed) 6 Current/voltage input 6 Measurement range of currents inputs (parameterizable) 0 to 20 mA 4 to 20 mA -30 to +30 mA Measuring range of voltage input (parameterizable) 0 to 10 V -10 to +10 V Input impedance, current 41.8 : Input impedance, voltage 100 k: Max. error (over the entire temperature range) 0.2% relative to full-scale value Resolution of A/D converter 13 bit + sign Conversion method Successive approximation 6/10 Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Distributed I/O on the PROFIBUS AddFEM: Redundant I/O module for fast response times ■ Selection and ordering data Order No. Front End Modules Front End Module AddFEM PROFIBUS DP I/O module with redundancy feature for fast response times, operable on automation systems of the SIMATIC PCS 7 process control system V7.1/V8.0 including Update 1 6DL3 100-8AC Front End Module AddFEM SoE PROFIBUS DP I/O module with redundancy feature for highly exact time stamping, operable on automation systems of the SIMATIC PCS 7 process control system V7.1/V8.0 including Update 1 6DL3 100-8AC03 ■ More information Siemens AG Industry Sector Industry Automation Division Control Components and Systems Engineering Karlsruhe Tel.: +49 721 595-6053 Fax: +49 721 595-6525 E-mail: [email protected] Accessories Connection elements for AddFEM • Plug set with screw-type terminals • Plug set with spring-loaded terminals 6DL9 900-8AA 6DL9 900-8AB Redundant connection Fiber-optic cable 1.6 m 6DL9 901-8AA SoE repeater module 6 channels 6DL9 200-8AA SoE repeater extension module 6 channels 6DL9 201-8AA Cable between time server and SoE repeater Glass FOC, length: • 15 m • 25 m 6DL9 902-8AA 6DL9 902-8AB Cable between SoE repeater and AddFEM SoE Plastic FOC, length: • 1.5 m • 2.5 m 6DL9 903-8AA 6DL9 903-8AB 6 Siemens ST PCS7 AO · 2013 6/11 © Siemens AG 2013 Distributed I/O on the PROFIBUS AirLINE Ex: Pneumatic block for integration into ET 200iSP ■ Overview ■ Design PCS 7 Add-on fit for SIMATIC PCS 7 V8 In the context of the AirLINE Ex 8650 pneumatic valve block, every assembly comprising terminal module, function module and pneumatic module is referred to as "slice". A valve slice comprises the terminal module with the permanent wiring, equipped with an electronic basic module and a pneumatic basic module. The valves are then mounted on the basic module. 6 AirLINE Ex 8650 is a pneumatic valve block specially developed for the ET 200iSP distributed I/O system of SIMATIC PCS 7, and is used to control process and production sequences in hazardous areas of Zone 1/21. Through integration of the pneumatic valve block into the ET 200iSP station, the latter's electric I/O functions are expanded by pneumatic 3/2-way or 5/ 2-way control functions. Pneumatic functions reduce the costs for wiring and the associated documentation. They save space, simplify the proof of intrinsic safety, and have a favorable effect on the power loss and the associated self-heating. Typical fields of application can be found in process and production automation associated with biotechnology and in the pharmaceutical and chemical industries. Note: As an integral component of the ET 200iSP, the AirLINE Ex 8650 pneumatic valve block can be used together with SIMATIC PCS 7 V7 or V8. It is linked using the IM 152-1 interface module of the ET 200iSP station. It is supported by means of the Generic Station Description (GSD), the Electronic Device Description (EDD) and the Hardware Support Package (HSP). Design of a valve slice (terminal module on left, electronic basic module at top, pneumatic basic module at bottom, valves) The valves and their electronic modules have intrinsically safe design (Ex i). For servicing purposes, they can be replaced during ongoing operation. They are easy to install and remove from the front. The AirLINE Ex 8650 pneumatic valve block is supplied with compressed air via pneumatic connection washers, and the exhaust air is also discharged in this manner. A connection washer on each side terminates the pneumatic backplane on the left and right to the modules of the ET 200iSP. Valve slices for the two available air supplies of 300 l/min and 700 l/min can be mixed in between as desired. Depending on the configuration, smaller supply elements can be produced using further pneumatic connection washers for intermediate supply. It is then possible to ensure the air supply for all valves even in critical situations, and to produce segments for different pressures. A configurator from Bürkert Fluid Control Systems can help you in the selection and combination of components. It will provide you with: • Documentation • Materials list • Dimensions • Various illustrations for your configuration 6/12 Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Distributed I/O on the PROFIBUS AirLINE Ex: Pneumatic block for integration into ET 200iSP ■ Function The AirLINE Ex 8650 pneumatic valve block can be used to implement 3/2-way and 5/2-way functions for controlling process valves, single-action or double-action pneumatic cylinders, linear or rotary actuators, etc. The valve slices for air supplies of 300 l/min or 700 l/min act like digital output modules. They convert the electric control signals of the interface module into pneumatic output signals. The valves themselves have a low power consumption and permit high pressures to be switched with short switching times. They are optionally available with or without manual emergency actuation. Versions are also available with a separate auxiliary control air supply for use in an extended pressure range or with a non-return valve for venting connections. The configuration can be individually adapted using optional baffle elements or pressure shut-offs. Up to 88 valve functions can be configured depending on the types of valve used. The electronics modules of the valve slices display the modules status (group fault display) and the channel status (channel open/closed) on LEDs. Status, diagnostics and switching cycle counters of the channels can be read out via PROFIBUS. ■ Technical specifications AirLINE Ex Max. number of valve functions 88 (depending on type of valve) Max. width of complete station 1185 mm Rated flow 300 l/min or 700 l/min Pressure range 0 … 8 bar Ambient temperature in operation • Horizontal installation • All other mounting positions 0 … 55 °C 0 … 50 °C Ambient temperature during storage -40 … +70 °C Degree of protection IP30 Approvals ATEX, IEC, II 2G Ex ia/ib IIC T4 ■ More information Bürkert Fluid Control Systems Christian-Bürkert-Str. 13-17 74653 Ingelfingen Germany 6 Tel.: +49 7940 10 - 0 Fax: +49 7940 10 - 91 204 E-mail: [email protected] Additional information is available on the Internet at: www.burkert.com Siemens ST PCS7 AO · 2013 6/13 © Siemens AG 2013 Distributed I/O on the PROFIBUS SIMATIC RF: RFID systems ■ Overview ■ Function PCS 7 Add-on fit for SIMATIC PCS 7 V8 SIMATIC RF RFID systems with a tag memory of up to 64 KB can be parameterized in many different manners. An application example with a CFC block on the CD "RFID Systems Software & Documentation" provides you with effective support. In order to utilize the full functionality of the RFID system for SIMATIC PCS 7, this example can be changed or extended as required. A customized CFC block can also be created by direct adaptation of the function blocks FB/FC 45. ■ Selection and ordering data 6 Radio Frequency Identification (RFID) systems for contactless identification and localization of products as well as for automatic recording and storage of data have already been tried and tested in numerous manners for automation technology. Such systems use mobile data carriers (transponders/tags) to identify products, and readers to monitor the data in the transponders. Using the SIMATIC RF RFID systems from Siemens it is possible to perfectly control and optimize the material flow and the complete logistics sequence. The systems are also highly suitable for container management and asset management. Note: The SIMATIC RF identification systems can be used together with SIMATIC PCS 7 V7 and V8. 6GT2 002-0ED00 ASM 475 communication module For SIMATIC S7-300 and ET 200M; for connecting two read devices 6GT2 002-0GA10 RFID Systems Software & Documentation With FB/FC for SIMATIC/SIMATIC PCS 7, application example and RFID documentation in 2 languages (English, German) 6GT2 080-2AA20 Engineering software, software class A, 5 languages (English, German, French, Italian, Spanish), single license for one installation Delivery package: Software and electronic documentation on DVD ■ More information Siemens AG Industry Sector Industry Automation Division Sensors and Communication Nuremberg Tel.: +49 911 895 2905 Fax: +49 911 895 15 2905 ■ Design The SIMATIC RF RFID systems consist of matched individual components whose function and performance vary depending on the task: • Mobile data carriers (transponders/tags) • Read/write devices (readers) and mobile handheld terminals • Antennas • Communication modules for connection to the automation system • Software for system integration Integration of the SIMATIC RF RFID systems into the SIMATIC PCS 7 process control system is possible in various manners. The RFID readers of the RF200, RF300, RF600, MOBY D/U systems are linked with the process control system using ASM 456 and ASM 475/ET 200M communication modules. ASM 456 and ASM 475/ET 200M communicate via PROFIBUS with the SIMATIC PCS 7 automation system. 6/14 Order No. ASM 456 communication module For connecting two read devices directly to PROFIBUS Siemens ST PCS7 AO · 2013 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.com/rfid © Siemens AG 2013 Distributed I/O on the PROFIBUS KSB PumpDrive for SIMATIC PCS 7: Speed control for centrifugal pumps ■ Overview PCS 7 Add-on Connection to SIMATIC PCS 7 fit for SIMATIC PCS 7 V8 The following components are required for the connection to SIMATIC PCS 7: • Software package KSB PumpDrive for SIMATIC PCS 7 • PROFIBUS module is offered by KSB as a PROFIBUS accessory set for the KSB PumpDrive The software package KSB PumpDrive for SIMATIC PCS 7 contains the following components: • Block library with: - Diagnostics block for integration into the SIMATIC PCS 7 driver concept - Signal block for control of a pump module - Block for Maintenance Station - Data block with parameter data sets • Faceplate ■ Function KSB PumpDrive is a control device based on state-of-the-art frequency converter technology for energy-efficient and lowwear operation of centrifugal pumps. KSB PumpDrive and corresponding sensors convert pumps into an intelligent, variable-speed pump system – either for individual operation or for multi-pump operation with up to 6 pumps. Such a pump system can be easily integrated into the SIMATIC PCS 7 process control system using the software package KSB PumpDrive for SIMATIC PCS 7. Note: The KSB PumpDrive software package for SIMATIC PCS 7 can be used together with SIMATIC PCS 7 V7.0, V7.1, and V8.0. ■ Design The faceplate allows direct access to all significant functions and states of the KSB PumpDrive: • Controlled variables • Speed (freely selectable from 0 to 70 Hz) • Multi-pump operation with up to 6 pumps • Switching-over of authorizations (local) • Display of: - Operating values (speed, current, actual value, etc.) - Fault history - Energy demand meter (kWh) - Operating hours counter (motor, frequency converter) - Display of current delivery rate – sensorless • Status of protection functions - Thermal motor protection - Electrical motor protection - Dynamic overload protection through speed limiting - Protection against running dry (sensorless or by external switching signal) - Performance data monitoring (avoidance of illegal operating states of hydraulics on basis of pump characteristic) ■ More information KSB Aktiengesellschaft Johann-Klein-Str. 9 67227 Frankenthal Germany Tel.: +49 6233 86-0 Fax: +49 6233 86-3401 KSB PumpDrive is a self-cooled frequency converter with control unit which allows continuous adjustment of the pump performance to the respective requirements. Hotline KSB Automation: +49 6233 86-2042 KSB PumpDrive has an integrated, adjustable PI controller for: • Differential pressure control • Level control • Temperature control • Flow control • Pressure control with setpoint tracking depending on the delivery rate www.ksb.com Additional information is available on the Internet at: As a result of its self-cooling, the KSB PumpDrive can be mounted on the motor (MM), on a wall (WM), or in a control cabinet (CM). Siemens ST PCS7 AO · 2013 6/15 6 © Siemens AG 2013 Distributed I/O on the PROFIBUS Notes 6 6/16 Siemens ST PCS7 AO · 2013 7 © Siemens AG 2013 Simulation 7/2 Introduction 7/3 SIMBApro FAT: Fieldbus simulation with Factory Acceptance Test 7/6 SIMIT: Simulation-based engineering Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Simulation Introduction ■ Overview G_PCS7_XX_00181 OS clients / multi-clients OS server Automation systems AS simulation with S7-PLCSIM 352),%86'3 Fieldbus simulation with SIMBApro FAT ET 200M Field devices Dynamic plant simulation with SIMIT T2659 7 LT WT LT Reactor 7/2 Siemens ST PCS7 AO · 2013 The following products are currently available for testing and simulation of an entire SIMATIC PCS 7 system or individual process control levels (automation level, field level ...): • S7-PLCSIM SIMATIC PCS 7 standard product for function testing of CFC/SFC user programs on PCs/PGs; refer to main catalog ST PCS 7 for description and ordering data • SIMBApro FAT SIMATIC PCS 7 add-on product based on SIMBA Profibus for field bus simulation (PROFIBUS DP), including numerous functions for the factory acceptance test (FAT) at unit level • SIMIT SIMATIC PCS 7 add-on product for dynamic plant simulation, for example, for the overall plant test or for operator training © Siemens AG 2013 Simulation SIMBApro FAT: Fieldbus simulation with Factory Acceptance Test ■ Overview PCS 7 Add-on fit for SIMATIC PCS 7 V8 Standard PC with configuration and diagnostics software External SIMBA Profibus module with 2, 4 or 8 channels Option: Several SIMBA Profibus modules networked over Ethernet SIMBA Profibus Ethernet SIMBA Profibus SIMATIC PCS 7 automation systems SIMBA Profibus 7 SIMBA Profibus PROFIBUS SIMBApro FAT is based on SIMBA Profibus, a system which is able to simulate the devices (PROFIBUS slaves) connected on the PROFIBUS DP fieldbus and the units operated on them (valves, motors, etc.). Of particular importance for the SIMATIC PCS 7 process control system is that SIMBA Profibus can also simulate safety-related and redundant PROFIBUS slaves. The simulation is reaction-free, i.e. it is irrelevant for the SIMATIC PCS 7 automation system (controller) as the master whether it communicates with real or simulated PROFIBUS slaves. Several PROFIBUS lines with simulated PROFIBUS slaves can be operated in parallel on one automation system. A PROFIBUS line can be completely simulated. However, real and simulated PROFIBUS slaves can also be combined together on a PROFIBUS line. Simple tests are possible by activating and monitoring the inputs/outputs. A comprehensive range of typicals supports operator control and monitoring of the individual PROFIBUS slaves as well as triggering of process and diagnostics alarms. Predefined equipment typicals are available for the Factory Acceptance Test (FAT) of plants. The simulation structure for the Factory Acceptance Test (FAT) can be created rapidly and simply using predefined simulation functions and various import options (e.g. hardware configuration from HW Config or equipment feedbacks from symbol table). Note: SIMBApro FAT can be used together with SIMATIC PCS 7 V7 and V8. Siemens ST PCS7 AO · 2013 7/3 © Siemens AG 2013 Simulation SIMBApro FAT: Fieldbus simulation with Factory Acceptance Test ■ Benefits 7 7 7 7 7 7 ■ Function Increase in quality standards for products and systems Saving of investments for test, commissioning and training systems Fast and low-cost conversion to new plant configurations Shortening of commissioning time as result of tested configurations Early detection and elimination of configuration errors Risk-free operator training ■ Application Configuration/engineering • Default settings, reading and modification of digital and analog inputs/outputs • Early testing of project-specific blocks (technological function, alarm behavior), example solutions and sequencers • Integration of mathematical formulas and simple linking of analog values 7 Factory Acceptance Test • Test without modifying the original software • Test of elementary automation functions (measurement and control loops, switching function) • Integration test of the entire automation architecture • Performance test through use of load generators • Test of safety-relevant functions (emergency shutdowns) • Documentation of the test results • Linking via API interface with simulation tools such as SIMIT for plant simulation ■ Design SIMBA Profibus comprises the following components: • External SIMBA Profibus module with 2, 4 or 8 channels • Configuration and diagnostics software for standard PC • Electronic documentation in HTML format The SIMBA Profibus module simulates the PROFIBUS message frame traffic. Depending on the number of channels, 2, 4 or 8 PROFIBUS lines each with up to 125 PROFIBUS slaves can be simulated in real-time with one module. It is also possible to network several SIMBA Profibus modules together via the Ethernet control interface. Altogether, a SIMBA project can thus comprise up to 32 PROFIBUS lines. The configuration and diagnostics software which can be used on a standard PC with Windows 2000 or XP communicates with the SIMBA Profibus modules over the standard Ethernet network interface. The software can be used to configure the SIMBA Profibus modules and to implement simple simulation functions for equipment. 7/4 Siemens ST PCS7 AO · 2013 SIMBApro FAT is able, with SIMBA Profibus, to completely simulate the response of I/O devices on the PROFIBUS DP fieldbus reaction-free. Additional functions for the Factory Acceptance Test (FAT) allow uniform testing of the automation architecture. Fault statuses can be simulated in addition to normal plant operation. All diagnostic options of the PROFIBUS DP are available, ranging from missing or incorrect feedbacks up to distributed I/O faults (failure of module, station or line). The configuration of the PROFIBUS DP and the PROFIBUS slaves can be imported from the SIMATIC PCS 7 project (HW Config). A library with easily configurable typicals for simulation of equipment (valves, pumps, switches etc.) is delivered together with the configuration and diagnostic software, and can be expanded by users with their own library elements. Equipment feedbacks are easy to generate using the equipment typicals. This process can be automated through time-saving importing of a STEP 7/PCS 7 symbol table. Simulation requirements extending beyond the scope of the Factory Acceptance Test, e.g. complete process simulations, can be implemented with SIMIT. SIMIT can read and write the data of SIMBApro FAT via an API interface. ■ Technical specifications • Baud rate of PROFIBUS DP: max. 12 Mbit/s • SIMBA Profibus modules with channels for 2, 4 or 8 PROFIBUS DP lines • Up to 125 PROFIBUS slaves can be simulated per PROFIBUS line • Maximum configuration with 8-channel SIMBA Profibus module: - Up to 8 single or 4 redundant PROFIBUS DP lines - Up to 8 x 125 PROFIBUS slaves • Up to 32 PROFIBUS lines per SIMBA project • PROFIBUS slaves which can be simulated: standard slaves and S7 slaves, also safety-related and redundant • Simple expansion with new PROFIBUS slaves • S7-specific PROFIBUS functions • Asynchronous PROFIBUS services • Process and diagnostics alarms can be triggered • Library for standard typicals • Generation of own simulation functions (typicals) • Import functions (HW-Config, symbol table) • Definition of import filters © Siemens AG 2013 Simulation SIMBApro FAT: Fieldbus simulation with Factory Acceptance Test ■ Selection and ordering data Order No. SIMBA Profibus 2-channel for 2 PROFIBUS lines with max. 125 PROFIBUS DP slaves each • 2-channel SIMBA Profibus module • Configuration and diagnostics software, runs with Windows 2000 and XP, engineering software, software class A, 2 languages (English, German), single license for 1 installation • Electronic documentation, 2 languages (English, German) 9AE4 122-1AA00 9AE4 122-1AC00 Delivery package: Software and electronic documentation on CD, certificate of license, module Delivery package: Software and electronic documentation on CD, certificate of license, module 4-channel for 4 PROFIBUS lines with max. 125 PROFIBUS DP slaves each • 4-channel SIMBA Profibus module • Configuration and diagnostics software, runs with Windows 2000 and XP, engineering software, software class A, 2 languages (English, German), single license for 1 installation • Electronic documentation, 2 languages (English, German) Order No. 8-channel for 8 PROFIBUS lines with max. 125 PROFIBUS DP slaves each • 8-channel SIMBA Profibus module • Configuration and diagnostics software, runs with Windows 2000 and XP, engineering software, software class A, 2 languages (English, German), single license for 1 installation • Electronic documentation, 2 languages (English, German) 9AE4 122-1AB00 Delivery package: Software and electronic documentation on CD, certificate of license, module 24 V DC plug-in power supply unit Option for supplying SIMBA PROFIBUS module with 24 V DC if a corresponding power supply is not available • Input voltage 230 V AC, 50 Hz • Output voltage 24 V DC, 2.5 A • Connection on the primary side: non-heating appliance socket • Connection on the secondary side: DC connector matching the SIMBA Profibus module 9AE4 130-1AA00 Services for every aspect of simulation • Support and consulting • Selection of simulation tools • Strategy for implementing the simulation • Creation of simulation solutions at fixed price On request 7 ■ More information Siemens AG Industry Sector Customer Services Division Value Services Karlsruhe Tel.: +49 721 595-6380 Fax: +49 721 595-6383 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.de/Simba Siemens ST PCS7 AO · 2013 7/5 © Siemens AG 2013 Simulation SIMIT: Simulation-based engineering ■ Overview PCS 7 Add-on SIMIT is a powerful simulation platform. It is integrated into the SIMATIC PCS 7 engineering by means of open interfaces, but functional expansions remain possible as a result of its modular design. It is not necessary to be a specialist to be able to create and use simulations with SIMIT. A graphical user interface is available for operation. All mathematical and IT procedures of a simulation are carried out by SIMIT invisibly in the background. SIMIT provides a versatile range of capabilities for virtual commissioning of SIMATIC user software. SIMIT supports both automatic configuration for signal tests and the simulation of any complex processes or complete plants in real time. In addition to a simple button-triggered PLC signal test, additional possible application examples include testing the drive level and physical simulation of the process response for a complete plant test or for operator training. SIMIT can be perfectly adapted to individual requirements with respect to functionality and scope. The basic system already provides powerful simulation functions. This functional scope can be selectively extended with specific hardware and software modules. In addition, SIMIT SBE offers a SIMIT configuration specially adapted for PCS 7 Engineering. 7 WinCC fit for SIMATIC PCS 7 V8 Simulation is supported by appropriate automated functions. For example, importing of a symbol table or a list of signal names is sufficient for automatic configuration of the signal links. If the Import/Export Assistant (IEA) is used in SIMATIC PCS 7 projects, the IEA data can be used in SIMIT for automatic establishment of a simulation environment. The standard patterns suitable for SIMATIC PCS 7 are already included in SIMIT. Note: SIMIT V7.0 can be used together with SIMATIC PCS 7 V7.0, V7.1 and V8.0. PCS 7 engineering PCS 7 HMI User software Symbol table Signals Actuators & sensors Process SIMIT Factory Acceptance Test (FAT) of the overall plant with SIMIT The Factory Acceptance Test (FAT) tests the complete automation functions. The actual automation systems (SIMATIC S7 controller) are loaded with the SIMATIC user software. SIMIT then simulates the input/output signals, instrumentation and field devices. The simulation values are transmitted as PROFIBUS DP message frames to the individual automation systems via the SIMIT interface modules (IM-PBDP). The link between SIMIT and the automation level is carried out automatically by the SIMATIC PCS 7 hardware configuration. As described for engineering on the PC, the IEA mechanisms can also be used to automatically generate the test environment. If SIMIT additionally handles the process simulation, the FAT then becomes a plant test. Commissioning of the automation functions can already be carried out in the virtual process in an early phase of the project. ■ Function SIMIT allows the user to create a simulation by simply "combining" individual components on a graphical user interface. The predefined components are selected from a library, connected together, and parameterized. Engineering on the PC with SIMIT The SIMATIC user program generated in SIMATIC PCS 7 is loaded into the PLC simulation S7-PLCSIM, and receives the simulated I/O signals from SIMIT via the PLCSIM coupling. Automatic configuration of the interface in SIMIT is carried out by importing the symbol table from SIMATIC PCS 7. However, automatic generation of the simulation environment is also possible using the PCS 7 Import/Export Assistant (IEA). The simulation templates tailored for SIMATIC PCS 7 V7.x can be adapted for use with SIMATIC PCS 7 V8.0. The complete interaction between automation and process is completed by means of a process model. By coupling the SIMATIC PCS 7 operator station with PLCSIM, the complete automation function from the sensor to the automation and visualization systems and back again to the actuator can be tested on the SIMATIC PCS 7 engineering system in the technical office without the actual automation hardware being present. 7/6 Siemens ST PCS7 AO · 2013 S7-PLCSIM Devices (IEA) WinCC PCS 7 engineering PCS 7 HMI User software Hardware configuration Devices (IEA) Signals Actuators & sensors Process © Siemens AG 2013 Simulation SIMIT: Simulation-based engineering ■ Function (continued) Training simulation with SIMIT Additional features In conjunction with SIMATIC PCS 7 and S7- PLCSIM, SIMIT forms the simulation platform for a training system. Plant operators can then be trained even before the real plant is fully functional. Apart from the standard library, FLOWNET provides a comprehensive library for simulation of media flows in pipeline networks. Individual library components or macro components can be created using editors. SIMIT's range of functions is rounded off by animated, user-configured graphics as well as trend windows for visualization of simulation values. The simulation models used provide realistic behavior of the plant under various operating conditions, e.g. on startup and shutdown, in the event of safety-related switch offs, etc. Where required, special simulators can also be linked to SIMIT via the standardized OPC client/server link. ■ Selection and ordering data Order No. Basic system SIMIT Basic V7.0 SIMIT basic system for Windows XP Professional SP3, Windows 7 Professional/Ultimate (all 32-bit); with complete electronic SIMIT documentation, 2 languages (English, German) SIMIT couplings 9AP1 420-1BB10 PRODAVE coupling V7.0 Software module for linking SIMIT to SIMATIC S7 controllers via the PRODAVE interface 9AP1 460-1CB10 Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product Engineering software, software class A, 2 languages (English, German), single license for one installation Engineering software, software class A, 2 languages (English, German), single license for one installation Delivery package: Software and electronic documentation on CD, certificate of license, USB dongle and license key SIMIT SBE V7.0 Preferred configuration for testing of SIMATIC PCS 7 user software, comprising: • SIMIT Basic V7.0 (9AP1 4201BB10) • PROFIBUS DP coupling V7.0 (9AP1 434-1CB10) • PROFINET IO coupling V7.0 (9AP1 438-1CB10) • PLCSIM coupling V7.0 (9AP1 433-1CB10) • MCE V7.0 (9AP1 440-1CB10) • DGE V7.0 (9AP1 442-1CB10) • TME V7.0 (9AP1 443-1CB10) • SMD V7.0 (9AP1 444-1CB10) • Complete electronic SIMIT documentation, 2 languages (English, German) Engineering software, software class A, 2 languages (English, German), single license for one installation Delivery package: Software and electronic documentation on CD, certificate of license, USB dongle and license key Order No. Delivery package: Certificate of license, license key 7 Notes: 9AP1 422-1BB10 Can only be used in conjunction with PRODAVE V6.1, MPI card, MPI adapter (USB, RS 232), MPI/ PROFIBUS or MPI/IE. Cannot be used on Windows 7. OPC link V7.0 Software module for linking SIMIT to clients or servers with OPC capability 9AP1 461-1CB10 Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product Engineering software, software class A, 2 languages (English, German), single license for one installation Delivery package: Certificate of license, license key PLCSIM link V7.0 Software module for linking SIMIT to S7-PLCSIM 9AP1 433-1CB10 Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product Engineering software, software class A, 2 languages (English, German), single license for one installation Delivery package: Certificate of license, license key Note: Can only be used in conjunction with S7-PLCSIM from version 5.2. Siemens ST PCS7 AO · 2013 7/7 © Siemens AG 2013 Simulation SIMIT: Simulation-based engineering ■ Ordering data PROFIBUS DP link V7.0 Software module for linking SIMIT to the PROFIBUS DP of SIMATIC S7 PLCs Order No. 9AP1 434-1CB10 SIMIT expansion module for generation of libraries and library elements Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product Engineering software, software class A, 2 languages (English, German), single license for one installation Engineering software, software class A, 2 languages (English, German), single license for one installation Delivery package: Certificate of license, license key Delivery package: Certificate of license, license key Note: Can only be used for and together with SIMIT interface modules 9AP2 440-1AB10, 9AP2 440-1AC10 and 9AP2 440-1AD10. DGE V7.0 9AP1438-1CB10 SIMIT expansion submodule for graphical processing of model graphs; animated graphics Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product Engineering software, software class A, 2 languages (English, German), single license for one installation Engineering software, software class A, 2 languages (English, German), single license for one installation Delivery package: Certificate of license, license key Delivery package: Certificate of license, license key TME V7.0 Note: May only be used for and together with SIMIT interface modules 9AP2430-2AA10 and 9AP24312AA10. SIMIT expansion module for graphic representation of signal profiles and display of messages Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product 9AP1 445-1CB10 Auto Control Interface SIMIT expansion module for generation and implementation of automated simulation procedures Engineering software, software class A, 2 languages (English, German), single license for one installation Delivery package: Certificate of license, license key Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product SMD V7.0 Engineering software, software class A, 2 languages (English, German), single license for one installation SIMIT expansion module for generation of models from templates and tables (PCS 7 Import/Export Assistant) Delivery package: Certificate of license, license key Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product Structured Model Diagrams 9AP1 440-1CB10 MCE V7.0 Macro Component Editor SIMIT expansion module for generation of macros from standard library elements Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product Engineering software, software class A, 2 languages (English, German), single license for one installation Delivery package: Certificate of license, license key 7/8 9AP1 443-1CB10 Trend & Message Editor SIMIT expansions ACI V7.0 9AP1 442-1CB10 Dynamic Graphics Editor Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product 7 9AP1 441-1CB10 Component Type Editor Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product PROFINET IO LINK V7.0 Software module for linking SIMIT to the PROFINET IO of SIMATIC S7 automation systems Order No. CTE V7.0 Siemens ST PCS7 AO · 2013 Engineering software, software class A, 2 languages (English, German), single license for one installation Delivery package: Certificate of license, license key 9AP1 444-1CB10 © Siemens AG 2013 Simulation SIMIT: Simulation-based engineering ■ Ordering data Order No. SIMIT library FLOWNET V7.0 SIMIT library for modeling media flows in pipeline networks using flow networks; contains process engineering components for modeling, such as valve, tank, pump, heat exchanger, etc. 9AP1 450-1CB10 Engineering software, software class A, 2 languages (English, German), single license for one installation IM-PNIO-128 Interface module for SIMIT for simulation of PROFINET IO devices: 1-channel interface module for the simulation of no more than 128 IO devices on an IO controller; same design as SIMBA PNIO Delivery package: Certificate of license, license key Documentation 9AP2 431-2AA10 Note: Can only be used with PROFINET IO link module 9AP1 438-1CB10. Complete SIMIT documentation in electronic form (PDF files) on CD is part of the SIMIT Basic product. SIMIT interface modules 9AP2 440-1AB10 IM-PNIO-256 Interface module for SIMIT for simulation of PROFINET IO devices: 1-channel interface module for the simulation of no more than 256 IO devices on an IO controller; same design as SIMBA PNIO 9AP2 430-2AA10 7 Note: Can only be used with PROFINET IO link module 9AP1 438-1CB10. Note: Can only be used with PROFIBUS DP linking module 9AP1 434-1CB10. IM-PBDP-4 Interface module for SIMIT for simulation of PROFIBUS DP slaves: 4-channel interface module, each channel for the simulation of no more than 125 DP slaves in a DP master system; same design as SIMBA PROFIBUS 9AP2 440-1AD10 Note: Can only be used with PROFIBUS DP linking module 9AP1 434-1CB10. Electronic documentation, 2 languages (English, German), is part of the SIMIT Basic product IM-PBDP-2 Interface module for SIMIT for simulation of PROFIBUS DP slaves: 2-channel interface module, each channel for the simulation of no more than 125 DP slaves in a DP master system; same design as SIMBA PROFIBUS Order No. IM-PBDP-8 Interface module for SIMIT for simulation of PROFIBUS DP slaves: 8-channel interface module, each channel for the simulation of no more than 125 DP slaves in a DP master system; same design as SIMBA PROFIBUS Service 9AP2 440-1AC10 SIMIT consulting Consulting on a daily basis, customer-specific training 9AP1 471-2AD00 Delivery package: Written contract Note: Can only be used with PROFIBUS DP linking module 9AP1 434-1CB10. ■ More information Siemens AG Industry Sector Industry Automation Division Process Automation Erlangen Tel.: +49 9131 7 43406 Fax: +49 9131 7 44060 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.com/simit Siemens ST PCS7 AO · 2013 7/9 © Siemens AG 2013 Simulation Notes 7 7/10 Siemens ST PCS7 AO · 2013 8 © Siemens AG 2013 Diagnostics 8/2 BANY: Bus analysis for SIMATIC Ethernet and PROFIBUS networks 8/4 ibaPDA/ibaAnalyzer: Fault tracking log - recording and analysis 8/6 PM-MAINT: Flexible maintenance management for SIMATIC PCS 7 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Diagnostics BANY: Bus analysis for SIMATIC Ethernet and PROFIBUS networks ■ Overview PCS 7 Add-on fit for SIMATIC PCS 7 V8 BANY is a tool based on Microsoft Windows for the documentation, diagnostics, recording and analysis of your SIMATIC S7/ PCS 7 Ethernet and PROFIBUS networks. The functionality for the analysis, diagnostics, and documentation of the Ethernet and PROFIBUS networks is shared between two independent program packages, which are offered both individually and as a bundle. Note: BANY can be used together with SIMATIC PCS 7 V7 and V8. ■ Design BANY PROFIBUS BANY PROFIBUS • The bus diagnosis provides you with information required to search for faults in PROFIBUS networks. Data such as bus load or lifelist is evaluated and displayed online. • The bus analysis synchronously records the message frame traffic on one or more PROFIBUS networks. It interprets the message frames across all levels, including SIMATIC S7/ PCS 7. Extensive trigger, filter, and sort functions enable faults to be quickly located. ■ Function 8 BANYnet Ethernet The plant manager is used for configuring the plant structure. All information is created in data structures. An import/export function allows data exchange with other programs. A userfriendly plant overview is automatically generated from the data structures. The Plant Manager can therefore be used for both documentation and configuration of Ethernet networks. Tables provide detailed information on the properties of the nodes. For documentation purposes, any information can be assigned to the individual devices/nodes. BANYnet Ethernet BANYnet Ethernet • The plant manager of BANYnet Ethernet provides valuable assistance in configuring your system: - Management of IP and MAC addresses - Automatic generation of plant image - Import and export functions • The plant diagnosis reads the configuration data and extensive message frame type statistics and error statistics from the SNMP-compatible network components. It provides you with information required to search for faults in the Ethernet network. Data such as bus load or lifelist is evaluated and displayed online. • The bus analysis synchronously records the message frame traffic on one or more Ethernet buses. It interprets the message frames across all levels, including SIMATIC S7/PCS 7. Extensive trigger, filter, and sort functions enable faults to be quickly located. 8/2 Siemens ST PCS7 AO · 2013 The Plant Diagnostics queries system data of SNMP-capable network nodes (e.g. switches, PCs), and thus provides the user with information on the configured nodes. The bus load display of the individual ports (numeric or graphic) and the list of nodes provide great assistance in locating errors in the Ethernet network. Statistics functions provide information on the number of individual message frame types (packet lengths, message frame types, error types, etc.). The events (traps) sent by the switch can be displayed in a list. Parameterization of Industrial Ethernet switches from the SIMATIC NET product range is also supported, e.g. IP address, port configuration or firmware update. The bus analysis with the integrated BANYmon permits convenient evaluation of recorded files (import/export of Netmon or sniffer files also possible). Errors can be rapidly located using predefined or user-generated filter and sorting functions. When one of the listed message frames is clicked, the associated detailed information is output. SIMATIC S7/PCS 7-specific message frames are interpreted and displayed according to their type (e.g. redundancy message frames, Alarm-8 message frames etc.). © Siemens AG 2013 Diagnostics BANY: Bus analysis for SIMATIC Ethernet and PROFIBUS networks ■ Function (continued) BANY PROFIBUS The bus diagnostics supplies special information about the bus and the associated nodes. Using a lifelist, it is possible at any time to check which nodes are connected to the bus and which of those is a master or slave. The bus load measurement provides information on bus bottlenecks and available reserves. The recorded message frames are interpreted according to their type (e.g. DP, FDL, DPV1 or DPV2) and processed into statistics. The bus analysis permits the recording, backup and convenient evaluation of bus events. It supports all baud rates from 9.6 kbaud through 12 Mbaud and determines these automatically. The recording can be carried out in a linear buffer or a cyclic buffer of selectable size. Long-term recording is possible in this manner. The start and end of recording can be automated using triggers. The data quantities can be reduced during the recording using predefined or user-created filter and sorting functions, and errors can be easily located by means of the subsequent analysis. When a listed message frame is clicked, its detailed information is output. Interpretation and representation of the SIMATIC S7/PCS 7-specific message frames depend on the type. The following protocols are interpreted: DP, FDL, DPV1, DPV2, FMS and S7. The BANY property of performing several recordings in parallel can be used for the redundancy analysis. For this purpose, BANY PROFIBUS is connected to the redundant bus lines. Since the recorded message frames are assigned synchronous time stamps, the communication flow can be easily compared. This allows fast and precise localization of redundancy problems. Note: The computer with the BANY PROFIBUS program package requires a CP 5512 (PC Card) communications processor for the PROFIBUS interface. The internal interfaces of programming devices cannot be used for this. ■ Selection and ordering data Order No. BANYnet Ethernet Bus analysis and diagnostics for SIMATIC Ethernet networks Program package for PC/PG, 2 languages (English, German), runs with Microsoft Windows NT/2000/XP Engineering and runtime software, software class A Delivery package: Software and electronic documentation on CD as well as license key dongle • Software protection by means of parallel/serial dongle • Software protection by means of USB dongle 9AE4 100-1DA00 9AE4 100-1DB00 BANY PROFIBUS Bus analysis and diagnostics for PROFIBUS networks Program package for PC/PG, 2 languages (English, German), runs with Microsoft Windows 2000/XP Engineering and runtime software, software class A Delivery package: Software and electronic documentation on CD as well as license key dongle • Software protection by means of parallel/serial dongle • Software protection by means of USB dongle On request 9AE4 100-1DE00 BANYnet – Bus analysis and diagnostics for Ethernet and PROFIBUS networks Program package for PC/PG, 2 languages (English, German), runs with Microsoft Windows 2000/XP 8 Engineering and runtime software, software class A Delivery package: Software and electronic documentation on CD as well as license key dongle • Software protection by means of parallel/serial dongle • Software protection by means of USB dongle On request 9AE4 100-1DF00 Network planning service, plant analysis/diagnostics on site and BANY training On request CP 5512 communications processor for the PC/PG connection to PROFIBUS or MPI 6GK1 551-2AA00 32-bit PC card (CardBus) with bus adapter for PROFIBUS Delivery package: PC card, bus adapter and product information ■ More information Siemens AG Industry Sector Customer Services Division Value Services Karlsruhe Tel.: +49 721 595-6380 Fax: +49 721 595-6383 E-mail: [email protected] Additional information is available on the Internet at: www.industry.siemens.com/services/global/en/IT4Industry/ products/diagnostics Siemens ST PCS7 AO · 2013 8/3 © Siemens AG 2013 Diagnostics ibaPDA/ibaAnalyzer: Fault tracking log - recording and analysis ■ Overview ■ Function PCS 7 Add-on 8 fit for SIMATIC PCS 7 V8 Whereas process control systems are generally operated with cycle times of between 50 ms and 4 s, faults can come and go at a considerably faster rate so that they are not detected within these CPU cycles. In addition, some faults only occur very sporadically. Systems such as ibaPDA and ibaAnalyzer for recording and analyzing fault sequence logs offer valuable support in tracing such faults. ibaPDA is a program package for recording fault sequence logs on a separate recording computer (PC) which is either connected to the PROFIBUS DP using a special PCI card from iba or communicates online with the automation system's CPU by means of the ibaPDA-interface-S7-Analyzer via MPI, CP/PG or Ethernet TCP/IP. By means of a recording computer, up to 2000 measured signals (digital and/or analog) can be recorded at a rate of up to 1 ms. Using ibaPDA-Request-S7, the measured data from the recording computer can be accessed and selected online without having to shut down the automation system's CPU. The signals recorded centrally with ibaPDA are stored in files and can be analyzed or visualized online from any number of workstations using the free ibaAnalyzer program package. The supplementary ibaAnalyzerDB package permits the convenient further processing of the recorded data with database support. Recorded data can be written to various databases (e.g. Microsoft SQL Server, Microsoft Access, Oracle) and read out again according to selectable query criteria. Note: ibaPDA and ibaAnalyzer can be used together with SIMATIC PCS 7 V7 and V8. 8/4 Siemens ST PCS7 AO · 2013 ibaPDA-V6 • Simple user interface with online signal visualization • Language versions with automatic adaptation to the operating system installation • Bar chart, digital and plot representation • Various viewer functions, e.g. chart recorder substitute, instruments, top view, etc. • Input of basic measurement clock from 50 μs (standard: 1 ms) • Client/server architecture, .net compatibility • Separation between configuration and measurement • Central configuration dialog with integrated online diagnostics • Flexible module structure • More than 2048 signals possible • Several recordings in parallel (expandable) • More Techno-Strings • OPC variables (OPC server and OPC client functionalities) • Virtual signals (formula editor) • Signal groups • Complex trigger frequencies • Digital output signals (alarm messages) • Timer control via DCF-77 • Look & feel similar to ibaAnalyzer ibaAnalyzer • Graphic user interface with intuitive operation • Automatic scaling • Report generator for automatic generation of graphic and tabular reports • OLE technology • Powerful mathematical formulae and operations • Views: Y/T, X/Y, FFT, Y/length, 2D plan, 3D false colors and 3D grid • Mathematically generated "virtual signals" • Graphical digital filter editor • Data export in ASCII format • Automatic presentation of measurement files (slide show) • Generation of analysis guidelines for use on several measurement files • Combination of signals on a shared scale or on different scales • Simultaneous consideration of analog and digital signals • X/Y zoom, infinitely variable • Special functions for length representations ibaAnalyzerDB • Data extraction of time-based and/or length-based measurement segments via ODBC in a database (e.g. Microsoft SQL Server, Microsoft Access, Oracle) • Database query wizard (Query Builder) • Database analysis with full scope of ibaAnalyzer instructions © Siemens AG 2013 Diagnostics ibaPDA/ibaAnalyzer: Fault tracking log - recording and analysis ■ Function (continued) S7 Direct Access • Connection of the recording system by means of PC card as PROFIBUS DP standard slave • Optional online access to almost all operands of the S7-400 • Exact cyclic output of measured data to the measuring system ibaPDA-interface-S7-Analyzer • Connection of recording system to automation system's CPU via MPI, CP/PG or Ethernet TCP/IP • Optional online access to almost all operands and symbols of the S7-400 • Output of measured data via the selected communication link (MPI, CP/PG or Ethernet TCP/IP) at processing rate of S7 system service ■ More information Iba AG Königswarterstraße 44 90762 Fürth Germany Tel.: +49 911-97282-0 Fax: +49 911-97282-33 E-mail: [email protected] Additional information is available on the Internet at: www.iba-ag.com Operating system platforms for all program packages • Windows XP 32-bit • Windows Server 2003 32-bit • Windows Vista 32-bit • Windows 7 32-bit • Windows Server 2008 32-bit 8 Siemens ST PCS7 AO · 2013 8/5 © Siemens AG 2013 Diagnostics PM-MAINT: Flexible maintenance management for SIMATIC PCS 7 ■ Overview ■ Design PCS 7 Add-on fit for SIMATIC PCS 7 V8 Maintenance PM-MAINT Client Production Plant bus 8 PM-MAINT is a sector/technology-independent maintenance management system for inspection, servicing and maintenance of production plants, and is primarily designed for preventive, performance-dependent maintenance. With the objective of maximizing plant availability, PM-MAINT uses the performance data or calendar intervals to generate predictive planning of maintenance measures. PM-MAINT determines the optimum time with regard to production and maintenance. Inspection and maintenance carried out too early increases the maintenance costs, and delayed implementation can result in production failures with high repair and downtime costs. PM-MAINT is linked to the automation level of the process control system via the SIMATIC PCS 7 operator system or per OPC. With its numerous import and export options, it is an ideal supplement for the SIMATIC PCS 7 Maintenance Station. Note: The PM-MAINT maintenance management system may be used in plants with SIMATIC PCS 7 V7 and V8. 8/6 Siemens ST PCS7 AO · 2013 Plant 1 PM-MAINT Client PM-MAINT Server Plant bus Plant x G_PCS7_XX_00242 WinCC/PCS 7 + PM-MAINT Server Example configuration of PM-MAINT in a client/server architecture PM-MAINT is scalable, and grows with your requirements. It can be used as a local single-user system or also as a distributed multi-user system in a client/server architecture. PM-MAINT can be installed in addition to the SIMATIC PCS 7 OS software on an operator station of version Single Station, Server, or Client. The PM-MAINT system software is structured as follows: • Type S for Single Station (single-user system) or Server (multiuser system) • Type C for Client (multi-user system) PM-MAINT supports Windows XP, Windows 7, Windows 2003 Server, and Windows 2008 Server. © Siemens AG 2013 Diagnostics PM-MAINT: Flexible maintenance management for SIMATIC PCS 7 ■ Function PM-MAINT permits mapping of the hierarchical plant structure of the company down to the level of the smallest units for maintenance. Maintenance jobs can be created for each maintenance object. Maintenance planning and activation In the case of performance-dependent maintenance, PM-MAINT utilizes operating hours and switching cycles from the current process data to calculate the recommended maintenance dates. When these dates are reached, PM-MAINT automatically creates the maintenance job. Additional options for creating maintenance jobs are process events or calendar intervals (days, weeks, months, quarters, years). Assignment of documents Any documents can be added as supplementary information to each maintenance object or job in the object tree, e.g. • Dimension drawings • Technical specifications • Maintenance information Job recording/checklists Maintenance jobs can be recorded manually or automatically. These reports are then used by the maintenance personnel as a checklist. Lists with ordering data for material requirements planning are additionally available for printing depending on the job. Processing of measures can also be documented in a report. Material and personnel assignment ■ Selection and ordering data Order No. PM-MAINT system software for SIMATIC PCS 7 V7 and V8 PM-MAINT system software Type S for a single station (single-user system) or a server (multi-user system), runs with Windows Server 2003, Windows Server 2008, Windows XP Professional, and Windows 7 9AE7 104-2SS30-1AA0 Engineering and runtime software, software class A, 2 languages (English, German), single license for one installation Type of delivery: software and electronic documentation on CD, dongle (hard lock), and certificate of license PM-MAINT system software Type C for a client (multi-user system), runs with Windows Server 2003, Windows Server 2008, Windows XP Professional, and Windows 7 9AE7 104-4SC00-1AA0 Engineering and runtime software, software class A, 2 languages (English, German), single license for one installation Type of delivery: software and electronic documentation on CD, dongle (hard lock), and certificate of license ■ More information The required material and personnel resources can be assigned to the maintenance jobs. The materials and working hours actually required can then be entered in the feedback relating to maintenance activities. Siemens AG Industry Sector Customer Services Division WinCC Competence Center Mannheim Archiving and analysis Phone: +49 621 456 3269 Fax: +49 621 456 3334 All maintenance activities are saved in an archive which is permanently evaluated to achieve a continuous improvement in maintenance procedures. Unexpected maintenance jobs can be recorded manually or by means of the SIMATIC PCS 7 Maintenance Station, and integrated into the long-term archiving. 8 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.de/process-management Siemens ST PCS7 AO · 2013 8/7 © Siemens AG 2013 Diagnostics Notes 8 8/8 Siemens ST PCS7 AO · 2013 9 © Siemens AG 2013 Laboratory automation 9/2 PCS 7 LAB Collection for laboratory automation Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Laboratory automation PCS 7 LAB Collection for laboratory automation ■ Overview ■ Design PCS 7 Add-on fit for SIMATIC PCS 7 V8 PCS 7 LAB Collection One feature of laboratory work is the frequent modification of experiments through which valuable knowledge, data and parameters are gained for series production. Particularly essential for automation of the laboratory - in addition to high quality, efficiency and safety - is therefore fast and flexible adaptation of the laboratory equipment to the automation technology. 9 With the PCS 7 LAB Collection we offer you a SIMATIC PCS 7 automation project that is explicitly tailored to these specific laboratory requirements. The matching SIMATIC PCS 7 system platform is described in detail in the configuration lists of this project. This enables you to assemble your laboratory automation system flexibly depending on the project specifications and to have an influence on the construction and installation technology. The selected components can be ordered separately by means of the SIMATIC PCS 7 Main Catalog ST PCS 7 and supplementary SIMATIC Catalogs. The PCS 7 LAB Collection is not only suitable for autonomous laboratory automation. The integration of the laboratory automation system into the SIMATIC PCS 7 plant network permits both an efficient exchange of information and the simple transfer of laboratory results to the production department. ■ Application Preferred field of application for the PCS 7 LAB Collection are: • Process-engineering laboratories in the process industry (chemical and pharmaceutical industries, biotechnology, food and beverage industry) • Training establishments (universities, technical colleges) • Test bench automation systems 9/2 Siemens ST PCS7 AO · 2013 The PCS 7 LAB Collection is preconfigured for the SIMATIC PCS 7 system platform defined in the following section. It supports the laboratory automation with SIMATIC PCS 7 by means of: • Setting the measurement ranges and units for analog values on the operator interface (OS) • Source code for the connection of serially communicating devices, e.g. - Sartorius scales - Huber thermostats - Bronkhorst coriolis flow meters • Examples for typical basic laboratory functions such as dosing, inerting, temperature monitoring etc. • Sample macros for: - Data export to Microsoft Excel - SFC control from Microsoft Excel • Functions for the definition of different access rights for laboratory personnel (Lab_Assistant) and laboratory operators (Lab_Operator) • Function blocks (including sample programs) for recording values up to a recording cycle time of 10 ms • Documented application examples © Siemens AG 2013 Laboratory automation PCS 7 LAB Collection for laboratory automation ■ Design (continued) System platform for PCS 7 LAB Collection The license of the PCS 7 LAB Collection authorizes the user to download a preconfigured laboratory automation project. In addition to automation examples of typical laboratory applications, this also includes the source code for the laboratory devices supported. Hardware and SIMATIC PCS 7 system software for automation, engineering, operator control and monitoring can be ordered individually using the following configuration lists, the main SIMATIC PCS 7 Catalog ST PCS 7, and the supplementary SIMATIC Catalogs, e.g. ST 70, ST 80 or IK PI. The hardware and software components described in the configuration lists of the PCS 7 LAB Collection are categorized as follows: • System for automation, engineering, operator control and monitoring, alternatives: - All-in-one system with the SIMATIC PCS 7 functionality for operator control and monitoring (OS), engineering (ES) and automation (AS) in one device: SIMATIC PCS 7 BOX RTX ES/OS compact system, or - Distributed system in which the AS functionality is exported to an external SIMATIC PCS 7 automation system: SIMATIC PCS 7 AS RTX and SIMATIC PCS 7 ES/OS system (e.g. SIMATIC PCS 7 BOX ES/OS system) • Distributed I/O for connection of laboratory devices, alternatives based on: - ET 200pro or - ET 200S • Components for serial connection of third-party devices, based on ET 200S Configuration list for SIMATIC PCS 7 BOX RTX ES/OS complete system Quantity Order no. Designation 1 6ES7 650-4AA11-■■■■ SIMATIC PCS 7 BOX RTX ES/OS system with SIMATIC PCS 7 ES, OS, and AS system functionality, assembled and preinstalled; based on SIMATIC IPC627C with Windows 7 Ultimate 32-bit operating system, multi-language (English, German, French, Italian, Spanish, Chinese) as well as with SIMATIC PCS 7 AS/OS Engineering Software V8.0 (unlimited POs), SIMATIC PCS 7 OS Software Single Station V8.0 including 250 OS Runtime POs, each in 5 languages (English, German, French, Italian, Spanish), and SIMATIC PCS 7 AS Runtime License for 250 AS Runtime POs (language-neutral) 1 -0GA■ Without panel -0GB■ 19" TFT Touch Panel, 1,280 x 1,024 pixels -0G■0 110/230 VAC industrial power supply to NAMUR; European power cable -0G■1 110/230 VAC industrial power supply to NAMUR; power cable for Great Britain -0G■2 110/230 VAC industrial power supply to NAMUR; power cable for Switzerland -0G■3 110/230 VAC industrial power supply to NAMUR; power cable for USA -0G■4 110/230 VAC industrial power supply to NAMUR; power cable for Italy -0G■5 110/230 VAC industrial power supply to NAMUR; power cable for China -0G■6 24 VDC industrial power supply 6ES7 652-0XD08-2YB5 SIMATIC PCS 7 SFC Visualization V8.0 for display and operation of SFC sequence controls on an operator station; 6 languages (English, German, French, Italian, Spanish, Chinese) 9 Optional accessories Quantity Order no. Designation 1 6ES7 648-0CB00-0YA0 SIMATIC PC keyboard (USB connection); with international key assignment 1 6ES7648-0BB00-0XA0 or SIMATIC IPC mouse, optical (BlueTrack), with USB connection, color: anthracite 6ES7648-0BB00-0XA1 SIMATIC IPC mouse, optical (BlueTrack), with USB connection, color: white 6GF6 220-1DA01 SCD 19101-D industrial LCD monitor 1 Desktop unit, 230 V AC, 48 cm (19") screen diagonal, horizontal frequency 50 ... 97 kHz, resolution 1280x1024, 16 million colors, IP20 degree of protection Further accessories: Possible additional accessories (to be provided by customer): • PROFIBUS cable Siemens ST PCS7 AO · 2013 9/3 © Siemens AG 2013 Laboratory automation PCS 7 LAB Collection for laboratory automation ■ Design (continued) Configuration list for combination of SIMATIC PCS 7 ES/OS system and SIMATIC PCS 7 AS RTX Example 1: SIMATIC PCS 7 BOX ES/OS system and SIMATIC PCS 7 AS RTX Quantity Order no. Designation 1 6ES7 650-4AA11-■■■■ SIMATIC PCS 7 BOX ES/OS with SIMATIC PCS 7 ES and OS system functionality, assembled and preinstalled; based on SIMATIC IPC627C with Windows 7 Ultimate 32-bit operating system, multi-language (English, German, French, Italian, Spanish, Chinese) as well as with SIMATIC PCS 7 AS/OS Engineering Software V8.0 (unlimited POs) and SIMATIC PCS 7 OS Software Single Station V8.0 including 250 OS Runtime POs, each in 5 languages (English, German, French, Italian, Spanish) -0JA■ Without panel -0JB■ 19" TFT Touch Panel, 1,280 x 1,024 pixels -0J■0 110/230 VAC industrial power supply to NAMUR; European power cable -0J■1 110/230 VAC industrial power supply to NAMUR; power cable for Great Britain -0J■2 110/230 VAC industrial power supply to NAMUR; power cable for Switzerland -0J■3 110/230 VAC industrial power supply to NAMUR; power cable for USA -0J■4 110/230 VAC industrial power supply to NAMUR; power cable for Italy -0J■5 110/230 VAC industrial power supply to NAMUR; power cable for China -0J■6 24 VDC industrial power supply 1 6ES7 654-0UE13-0XX0 SIMATIC PCS 7 AS RTX Assembled and preinstalled automation system on the basis of the SIMATIC IPC427C with Windows XP Embedded Standard 2009 operating system, WinAC RTX 2010 controller software, and SIMATIC IPC DiagMonitor diagnostics software, preinstalled on a 4 GB CompactFlash Card, suitable for SIMATIC PCS 7 V7.1 SP2 or higher and SIMATIC PCS 7 V8.0; 1 6ES7 653-2BA00-0XB5 SIMATIC PCS 7 AS Runtime License for 100 POs can be cumulated, language-neutral 1 6ES7 652-0XD08-2YB5 SIMATIC PCS 7 SFC Visualization V8.0 for display and operation of SFC sequence controls on an operator station; 6 languages (English, German, French, Italian, Spanish, Chinese) SIMATIC PCS 7 AS Runtime License for 100 POs Example 2: Other SIMATIC PCS 7 ES/OS system and SIMATIC PCS 7 AS RTX 9 If the SIMATIC PCS 7 AS RTX is not combined with a SIMATIC PCS 7 BOX ES/OS system but with a different SIMATIC PCS 7 ES/OS system, the SIMATIC PCS 7 AS/OS Engineering Software Quantity Order no. and the SIMATIC PCS 7 OS Software Single Station are not part of the scope of delivery, and must be ordered separately. The above configuration list is then changed as follows: Designation SIMATIC PCS 7 ES/OS system as alternative to SIMATIC PCS 7 BOX ES/OS system (included with product or Order no. of a SIMATIC PCS 7 Industrial Workstation selected per configurator) 1 1 6ES7 654-0UE13-0XX0 SIMATIC PCS 7 AS RTX Assembled and preinstalled automation system on the basis of the SIMATIC IPC427C with Windows XP Embedded Standard 2009 operating system, WinAC RTX 2010 controller software, and SIMATIC IPC DiagMonitor diagnostics software, preinstalled on a 4 GB CompactFlash Card, suitable for SIMATIC PCS 7 V7.1 SP2 or higher and SIMATIC PCS 7 V8.0; 1 6ES7 653-2BA00-0XB5 SIMATIC PCS 7 AS Runtime License for 100 POs can be cumulated, language-neutral 1 6ES7 652-0XD08-2YB5 SIMATIC PCS 7 SFC Visualization V8.0 for display and operation of SFC sequence controls on an operator station; 6 languages (English, German, French, Italian, Spanish, Chinese) 1 6ES7 658-5AX08-0YA5 SIMATIC PCS 7 AS/OS Engineering Software V8.0 Unlimited POs, 5 languages (English, German, French, Italian, Spanish) 1 6ES7 658-2AA08-0YA0 SIMATIC PCS 7 OS Software Single Station V8.0 incl. 100 OS Runtime POs, 5 languages (English, German, French, Italian, Spanish) 1 6ES7 658-2XA00-0XB0 SIMATIC PCS 7 OS Runtime License 100 POs for adding OS Runtime POs, can be cumulated, language-neutral SIMATIC PCS 7 AS Runtime License for 100 POs Optional accessories Quantity Order no. Designation 1 6ES7 648-0CB00-0YA0 SIMATIC PC keyboard (USB connection); with international key assignment 1 6ES7648-0BB00-0XA0 or SIMATIC IPC mouse, optical (BlueTrack), with USB connection, color: anthracite 6ES7648-0BB00-0XA1 SIMATIC IPC mouse, optical (BlueTrack), with USB connection, color: white 6GF6 220-1DA01 SCD 19101-D industrial LCD monitor 1 Desktop unit, 230 V AC, 48 cm (19") screen diagonal, horizontal frequency 50 ... 97 kHz, resolution 1280x1024, 16 million colors, IP20 degree of protection Further accessories: Possible additional accessories (to be provided by customer): • PROFIBUS cable 9/4 Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Laboratory automation PCS 7 LAB Collection for laboratory automation ■ Design (continued) Additional accessories Configuration list for ET 200pro I/O system SF SF SF SF SF SF SF Possible additional accessories (to be provided by customer): • Cable material for connection of 120/230 VAC supply • Cable material for 24 VDC power supply • PROFIBUS cable • M12 connector for ET 200pro 4 AI 0/4 ... 20 mA 4 AI ± 10 V 4 AI RTD 4 AO 0/4 ... 20 mA 4 AO ± 10 V 8 DI 24 V DC 4 DO 24 V DC/2 A Arrangement of the ET 200pro modules to match the configuration Quantity Order no. Designation 1 6ES7 141-4BF00-0AB0 Digital input module 8 DI for ET 200pro High Feature, 24 V DC, with module diagnostics; including bus module 1 6ES7 142-4BD00-0AB0 Digital output module 4 DO for ET 200pro High Feature, 24 V DC, 2 A, with module diagnostics; including bus module 1 6ES7 144-4FF00-0AB0 Analog input module 4 AI U for ET 200pro High Feature, ± 10 V; ± 5 V; 0 ... 10 V; 1 ... 5 V, with channel diagnostics; including bus module 1 6ES7 144-4GF00-0AB0 Analog input module 4 AI I for ET 200pro High Feature, ± 20 mA; 0 ... 20 mA; 4 ... 20 mA, with channel diagnostics; including bus module 1 6ES7 144-4JF00-0AB0 Analog input module 4 AI RTD for ET 200pro High Feature, resistors: 150, 300, 600 and 3000 :; resistance thermometers: Pt100, 200, 500, 1000, Ni100, 120, 200, 500 and 1000; with channel-discrete diagnostics, including bus module. 1 6ES7 145-4FF00-0AB0 Analog output module 4 AO U for ET 200pro High Feature, ± 10 V; 0 ... 10 V; 1 ... 5 V, channel diagnostics; including bus module 1 6ES7 145-4GF00-0AB0 Analog output module 4 AO I for ET 200pro High Feature, ± 20 mA; 0 ... 20 mA; 4 ... 20 mA, channel diagnostics; including bus module 1 6ES7 154-2AA01-0AB0 Interface module IM 154-2 for ET 200pro High Feature; including terminating module 6 6ES7 194-4CA00-0AA0 Interface module CM IO 4 x M12 4 x M12 sockets for connection of digital/analog sensors or actuators to ET 200pro 1 6ES7 194-4CB00-0AA0 Interface module CM IO 8 x M12 8 x M12 sockets for connection of digital sensors or actuators to ET 200pro 1 6ES7 194-4GA00-0AA0 ET 200pro module rack, narrow for interface, electronics and power modules: 500 mm Optional accessories Quantity Order no. Designation 1 6EP1 336-3BA00 SITOP modular 20 Stabilized power supply; input: 120/230 VAC, output: 24 VDC/20 A Siemens ST PCS7 AO · 2013 9/5 9 © Siemens AG 2013 Laboratory automation PCS 7 LAB Collection for laboratory automation ■ Design (continued) Additional accessories Configuration list for ET 200S I/O system Possible additional accessories (to be provided by customer): • Cable material for connection of 120/230 VAC supply • Cable material for 24 VDC power supply • PROFIBUS cable 5 x 2 DO 24 V DC, 2 A 2 x 2 AI 0/4 ... 20 mA 2-wire 5 x 4 DI 24 V DC 2 x 2 AI 0 ... 10 V 2 x 2 AI 0/4 ... 20 mA 4-wire 2 x 2 AO 0 ... 10 V 2 x 2 AO 0/4 ... 20 mA 1 x 2/4 AI RTD Arrangement of the ET 200S modules to match the configuration 9 Quantity Order no. Designation 1 6ES7 131-4BD01-0AB0 DI 4 x DC 24 V, High Feature; digital input module for ET 200S with diagnosis; short-circuit monitoring; ordering unit: 5 units 1 6ES7 132-4BB31-0AB0 DO 2 x DC 24 V/2 A, High Feature, digital output module for ET 200S with diagnostics; channel-based switching of substitute value on failure of CPU (parameterizable), channel-based short-circuit monitoring, channel-based wire-break monitoring (on "1" signal); Ordering unit: 5 units 2 6ES7 134-4FB01-0AB0 AI 2 x U (± 5 V, 1 ... 5 V, ± 10 V)/13 bit, standard analog input module for ET 200S; module-internal diagnostics, overflow/underflow diagnostics 2 6ES7 134-4GB01-0AB0 AI 2 x I, 2-wire MU (4 ... 20 mA)/13 bit, standard analog input module for ET 200S; module-internal diagnostics, overflow/underflow diagnostics, wirebreak monitoring 2 6ES7 134-4GB11-0AB0 AI 2 x I, 4-wire MU (± 20 mA, 4 ... 20 mA)/13 bit, standard analog input module for ET 200S; module-internal diagnostics, overflow/underflow diagnostics, wirebreak monitoring 1 6ES7 134-4JB51-0AB0 AI 2/4 x RTD standard for resistance thermometers or resistance measurement Analog input module for ET 200S • 2 inputs (3-wire and 4-wire connection) / 4 inputs (2-wire connection) • Max. resolution 15 bits + sign • Resistance thermometer Pt100, Ni100 • Module diagnostics: Overflow/underflow, internal fault, parameterization error • Channel-based wire-break monitoring 2 6ES7 135-4LB02-0AB0 AO 2 x U (1 ... 5 V, ± 10 V)/15 bit, high feature analog output module for ET 200S • Diagnostics inside module • Parameterizable connection of substitute value in case of CPU stop • Short-circuit monitoring 2 6ES7 135-4MB02-0AB0 AO 2 x I (± 20 mA, 4 ... 20 mA)/15 bit, high feature analog output module for ET 200S • Diagnostics inside module • Parameterizable connection of substitute value in case of CPU stop • Short-circuit monitoring 1 6ES5 710-8MA11 SIMATIC S5, 35 mm DIN rail, length 483 mm for 19" cabinets 5 6ES7 193-4CA40-0AA0 Terminal module TM-EE15S26-A1 2 × 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw terminals; ordering unit: 5 units 2 6ES7 138-4CA01-0AA0 PM-E power module; 24 V DC/10 A • Monitoring of the load voltage 2 6ES7 193-4CC20-0AA0 Terminal module TM-P15S23-A1 2 × 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw terminals; ordering unit: 1 unit 1 6ES7 151-1BA02-0AB0 Interface module IM 151-1 for ET 200S, High Feature Optional accessories Quantity Order no. Designation 1 6EP1 336-3BA00 SITOP modular 20 Stabilized power supply; input: 120/230 VAC, output: 24 VDC/20 A 9/6 Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Laboratory automation PCS 7 LAB Collection for laboratory automation ■ Design (continued) Configuration list for ET 200S components for serial connection of third-party devices The PCS 7 LAB Collection supports the connection of devices communicating in serial mode via ET 200S interface modules 1SI. A block library for addressing the devices is supplied with the PCS 7 LAB Collection. Quantity Order no. Designation 8 6ES7 138-4DF01-0AB0 Interface module 1SI with RS 232C/422/485 serial interface; ASCII and 3964R protocol 1 6ES5 710-8MA11 SIMATIC S5 35 mm DIN rail 2 6ES7 193-4CA40-0AA0 Length: 483 mm (for 19" cabinets) TM-E15S26-A1 terminal module 2 x 6 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals; Ordering unit: 5 units 1 6ES7 138-4CA01-0AA0 1 6ES7 193-4CC20-0AA0 PM-E power module; 24 V DC/10 A With monitoring of the load voltage TM-P15S23-A1 terminal module 2 x 3 terminals, terminal access to AUX1 bus, AUX1 interconnected to the left, screw-type terminals; Ordering unit: 1 units 6ES7 151-1BA02-0AB0 1 Interface module IM 151-1 for ET 200S, High Feature Installation Setup and installation depend on the space available and the requirements of the operating environment in the laboratory. According to the construction guidelines of the SIMATIC PCS 7 process control system, the products defined by means of the configuration lists are suitable not only for wall mounting, but also for mounting in enclosures or cabinets. This enables you to be very flexible in planning the construction. Both centralized and distributed structure versions can be implemented. 9 ■ Selection and ordering data PCS 7 LAB Collection Order No. 6DL5 408-8AX01-0XL1 License for preconfigured SIMATIC PCS 7 automation project for laboratory automation Runtime software, software class A, 2 languages (English, German), single license for 1 installation Delivery package: Certificate of License Note: The Certificate of License authorizes the user to download the PCS 7 LAB Collection software at the following address on the Internet. http://support.automation.siemens.com/WW/view/en/43884296 The PCS 7 LAB Collection software is preconfigured for the I/O modules of the ET 200pro or ET 200S distributed I/O systems defined in a configuration list. They include, among others: • Function block library for communication via ASCII protocol • Function blocks for high-speed event-controlled process value recording using the AR_SEND function • Documented examples of applications 9/7 Siemens ST PCS7 AO · 2013 ■ More information Additional information is available on the Internet at: www.siemens.com/simatic-pcs7-lab © Siemens AG 2013 Laboratory automation Notes 9 9/8 Siemens ST PCS7 AO · 2013 10 © Siemens AG 2013 Switchgear/controlgear automation 10/2 IEC 61850 library for integration of protectective equipment in SIMATIC PCS 7 10/3 Station controller for SIMATIC PCS 7 PowerControl 10/4 Station gateway for SIMATIC PCS 7 PowerControl Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Switchgear/controlgear automation IEC 61850 library for integration of protectective equipment in SIMATIC PCS 7 ■ Overview ■ Technical specifications PCS 7 Add-on fit for SIMATIC PCS 7 V8 SIMATIC PCS 7 OS clients SIMATIC PCS 7 OS servers Engineering station, e.g. DIGSI SIMATIC PCS 7 automation system IEC 61850 Intelligent field devices with IEC 61850 communication protocol The IEC 61850 protocol based on Ethernet TCP/IP is a globally valid open standard used for the communication of field devices in the protection and control systems of medium-voltage and high-voltage switchgear. This simplifies the configuration, guarantees the compatibility of future expansions, reduces the maintenance requirements, and thus also the total lifecycle costs. Leading manufacturers of protective equipment have therefore already implemented the IEC 61850 protocol in their products. 10 Blocks from the universal IEC 61850 communication block library which are suitable for reading and writing IEC 61850 tags support the integration of IEC 61850 protective equipment into the SIMATIC PCS 7 process control system by signaling critical switchgear statuses by means of alarms on the SIMATIC PCS 7 operator station. They have full access to the tags of the protective equipment and control devices (including time stamp) and make available the alarm information provided with the original time stamp of the IEC 61850 protective equipment to the SIMATIC PCS 7 operator station for visualization. The communication blocks can be positioned in the CFC Editor on a CFC chart. A connection is created in NetPro to each IEC 61850 device. Note: The IEC 61850 communication block library for SIMATIC PCS 7 can be used together with SIMATIC PCS 7 V7.1 or V8. 10/2 Siemens ST PCS7 AO · 2013 • Client functionality IEC 61850 MMS (Manufacturing Messaging Specification) • Up to 16 IEC 61850 devices per CPU of a SIMATIC PCS 7 automation system (depending on availability of memory and cycle time) • Read and write variables • Updating cycle < 1 s (depending on cycle time) • Transfer of original device time stamps to the SIMATIC PCS 7 operator station • Support of redundant automation systems ■ Selection and ordering data Order No. IEC 61850 library for integration of protective equipment for SIMATIC PCS 7 IEC 61850 communication block library for SIMATIC PCS 7 Communication blocks for connection of protective devices with IEC 61850 protocol to SIMATIC PCS 7 V7.1/V8, electronic documentation as well as engineering and runtime licenses for one project 9AE4 110-2AB00 Engineering and runtime software, software class A, 2 languages (English, German), plant license (naming of plant is necessary) Delivery package: Software and electronic documentation on CD, engineering and runtime license ■ More information Siemens AG Industry Sector Customer Services Division Value Services Karlsruhe Tel.: +49 721 595-6380 Fax: +49 721 595-6383 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.de/s7_iec61850 © Siemens AG 2013 Switchgear/controlgear automation Station controller for SIMATIC PCS 7 PowerControl ■ Overview ■ Technical specifications PCS 7 Add-on • IEC 61850 MMS client protocol with support for up to 64 server connections • IEC 61850 MMS client functionality: - Reading/writing of tags - Select/operate - Buffered reporting • IEC 61850 MMS server protocol with support for up to 5 client connections • Importing of ICD and SCD files of the protective equipment • Original time stamp from the protective equipment • Update cycle of < 500 ms is possible (depends on the CPU cycle time, data volume, network load might be much higher) • Configuration tool and SC_DRV library included in delivery fit for SIMATIC PCS 7 V8 PCS 7 OS clients PCS 7 OS server (redundant) PCS 7 plant bus Substation PCS 7 AS mEC RTX station controller G_PCS7_XX_00330 TCP/IP communication with IEC 61850 FO ■ Selection and ordering data The systems for automating processes and switchgear/ controlgear are growing together within industrial plants. Joint monitoring and control with only one control system offers potential savings with regard to investments, maintenance, and operation. The IEC 61850 standard has become established as the global standard for integration of switchgear/controlgear automation into the control system. All leading manufacturers of protective equipment have already implemented this standard in their devices. The station controller for SIMATIC PCS 7 PowerControl based on the PCS 7 AS mEC RTX controls the transfer of electrical data between the intelligent electronic devices (IEDs), e.g. protective equipment, and the superimposed operator system using the IEC 61850 MMS protocol. It is particularly suitable for small to medium-sized systems with standard availability requirements (no redundancy). Note: The station controllers for SIMATIC PCS 7 PowerControl based on the PCS 7 AS mEC RTX can be used together with SIMATIC PCS 7 V8. ■ Function During IEC 61850 MMS communication with the IEDs (protective equipment), the station controller acts like an IEC 61850 MMS client. The IEDs are IEC 61850 MMS servers. All IEC 61850 tags in the IED can be addressed via the station controller. Time stamp, value, and status of the tags are transferred depending on the configuration. The time stamp always originates from the protective equipment. Configuration of the data function is supported by a standard tool. The SC_DRV library included in the delivery is available for CFC configuration. Further protocols for the station controller are available on request for special applications. Order No. Station controller bundles for SIMATIC PCS 7 PowerControl Station controller bundle IEC 61850 MMS-Client based on SIMATIC PCS 7 AS mEC RTX SIMATIC PCS 7 AS mEC RTX preconfigured as station controller for PCS 7 PowerControl, with IEC 61850 MMS client protocol for up to 64 server connections Engineering and runtime software, software class A, 2 languages (English, German) Delivery package: Controller hardware, USB dongle, CD with documentation, configuration tool, and function block library, restore CD 9AE4 100-1GB20 Station controller bundle IEC 61850 MMS-Client/Server based on SIMATIC PCS 7 AS mEC RTX SIMATIC PCS 7 AS mEC RTX preconfigured as station controller for PCS 7 PowerControl, with IEC 61850 MMS client protocol for up to 64 server connections and IEC 61850 MMS server protocol for up to 5 client connections Engineering and runtime software, software class A, 2 languages (English, German) Delivery package: Controller hardware, USB dongle, CD with documentation, configuration tool, and function block library, restore CD 9AE4 100-1GB30 Station controller bundle IEC 61850 MMS-Server based on SIMATIC PCS 7 AS mEC RTX SIMATIC PCS 7 AS mEC RTX preconfigured as station controller for PCS 7 PowerControl, with IEC 61850 MMS server protocol for up to 5 client connections Engineering and runtime software, software class A, 2 languages (English, German) Delivery package: Controller hardware, USB dongle, CD with documentation, configuration tool, and function block library, restore CD 9AE4 100-1GB10 10 ■ More information Siemens AG Industry Sector Customer Services Division Value Services Karlsruhe Tel.: +49 721 595-6380 Fax: +49 721 595-6383 E-mail: [email protected] Siemens ST PCS7 AO · 2013 10/3 © Siemens AG 2013 Switchgear/controlgear automation Station gateway for SIMATIC PCS 7 PowerControl ■ Overview PCS 7 Add-on fit for SIMATIC PCS 7 V8 PCS 7 OS clients PCS 7 OS clients PCS 7 OS server (redundant) PCS 7 OS server (single) PCS 7 plant bus PCS 7 plant bus AS 41xH S7 communikation Substation Station gateway S7 communikation Substation TCP/IP communication with IEC 61850 FO TCP/IP communication with IEC 61850 FO A trend encountered in the planning and modernization of industrial plants is that the previously separated systems for automating processes and switchgear/controlgear are merging. Significant savings with regard to investments, maintenance, and operation can be achieved using one control system for joint monitoring and control of process and switchgear/controlgear. 10 The station gateway for SIMATIC PCS 7 PowerControl can integrate intelligent electronic devices (IEDs), e.g. protective equipment, into the SIMATIC PCS 7 process control system via the automation system. As opposed to the station controller, the station gateway is also suitable for redundant configurations and is therefore preferably recommended where increased availability requirements exist. The station gateway uses S7 communication for data exchange with the automation system, and the IEC 61850 MMS protocol for communication with the IEDs. The IEC 61850 standard has already become established as the global standard for integration of switchgear/controlgear automation into the control system. All leading manufacturers of protective equipment have already implemented this standard in their devices. Note: The station gateway for SIMATIC PCS 7 PowerControl can be used together with SIMATIC PCS 7 V7.1 or V8. 10/4 Siemens ST PCS7 AO · 2013 Redundant station gateway G_PCS7_XX_00331 AS 41x ■ Function During IEC 61850 MMS communication with the IEDs (protective equipment), the station controller acts like an IEC 61850 MMS client. The IEDs are IEC 61850 MMS servers. All IEC 61850 tags in the IED can be addressed via the station controller. Time stamp, value, and status of the tags are transferred depending on the configuration. The time stamp always originates from the protective equipment. Configuration is carried out in the CFC Editor with predefined blocks from the supplied SG_LINK communications library. The blocks available for various types of device are preparameterized for a standard scope of tags, but can also be reparameterized without problem for special project requirements. The station gateway communicates with the SIMATIC PCS 7 automation system via its CP 443-1 communication module, and uses the standard communication mechanisms of SIMATIC PCS 7 (BSEND/BRECV). The communication blocks with integrated connection diagnostics can be positioned in the CFC Editor on a CFC chart. A changed connection status, e.g. failure or re-establishment, is signaled in the SIMATIC PCS 7 Operator System by means of an alarm. © Siemens AG 2013 Switchgear/controlgear automation Station gateway for SIMATIC PCS 7 PowerControl ■ Technical specifications • Connection of up to 128 intelligent electronic devices (IEDs) via IEC 61850 MMS protocol • IEC 61850 MMS client functionality: - Reading/writing of tags - Select/operate - Buffered reporting • Original time stamp from the IED (protective equipment) • Connection of up to 8 SIMATIC PCS 7 automation systems • Support of redundant AS 41xH automation systems and standard AS 41x automation systems • Use of redundant station gateways is also possible with standard AS 41x automation systems • One S7 connection per station gateway to AS 41x (configuration in NetPro) • Four S7 connections per redundant station gateway to AS 41xH (configuration in NetPro) • Update cycle of < 500 ms is possible (depends on the CPU cycle time, data volume, network load might be much higher) ■ Selection and ordering data Order No. Station gateways for SIMATIC PCS 7 PowerControl Station gateway for SIMATIC PCS 7 PowerControl, single version Station gateway including SG-LINK block library for connection of intelligent electronic devices to SIMATIC PCS 7 automation systems using the IEC 61850 MMS protocol Engineering and runtime software, software class A, 2 languages (English, German) Delivery package: Station gateway hardware and CD with software and electronic documentation 9AE4 100-1EC00 Station gateway for SIMATIC PCS 7 PowerControl, redundant version Redundant station gateway including SG-LINK block library for connection of intelligent electronic devices to SIMATIC PCS 7 automation systems using the IEC 61850 MMS protocol Engineering and runtime software, software class A, 2 languages (English, German) Delivery package: Station gateway hardware and CD with software and electronic documentation 9AE4 100-1EC10 ■ More information Siemens AG Industry Sector Customer Services Division Value Services Karlsruhe Tel.: +49 721 595-6380 Fax: +49 721 595-6383 E-mail: [email protected] 10 Additional information is available on the Internet at: www.siemens.de/s7_iec61850 Siemens ST PCS7 AO · 2013 10/5 © Siemens AG 2013 Switchgear/controlgear automation Notes 10 10/6 Siemens ST PCS7 AO · 2013 11 © Siemens AG 2013 Power management 11/2 SIMATIC powerrate for PCS 7: Energy data evaluation/ energy management 11/6 WinCC/B.Data 11/9 Library 3WL/3VL for SIMATIC PCS 7 11/10 Library 7KM PAC3200 for SIMATIC PCS 7 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Power management SIMATIC powerrate for PCS 7: Energy data evaluation/energy management ■ Overview ■ Benefits 7 PCS 7 Add-on fit for SIMATIC PCS 7 V8 7 7 7 7 7 7 Identification of energy-intensive loads and processes for the purpose of deriving measures for improving energy efficiency Comparison of consumption profiles for more efficient processes Optimization of company according to energy parameters based on an assessment of consumption and costs Observation of supply limits agreed in contract to avoid higher energy supply costs or penalty payments Integration of the 7KM PAC3200/PAC4200 measuring devices for a fast overview of selected measured values and alarms Integration of switches to provide information on the switch status and with the possibility for switching over Accurate assignment and comparison of the consumption data of specific work processes or batches ■ Design A prerequisite for improving the energy balance is exact knowledge of the consumption profile. Potential savings can only be identified when it is known how much of each type of energy is used. With SIMATIC powerrate you can make the energy consumption transparent – from the infeed up to the consumer. SIMATIC powerrate can continuously record, save, and process the energy data, and visualize it on a faceplate. The integrated load management function allows active monitoring of power limits according to process-specific and user-specific definitions. You are then able to fully utilize the power limits agreed in contracts, and avoid unnecessarily high energy prices or even penalty payments. SIMATIC powerrate is completely integrated in SIMATIC PCS 7. Standard functionalities and standard interfaces of the process control system, e.g. to SIMATIC IT, can be used by SIMATIC powerrate without problem. Note: 11 SIMATIC powerrate V4.0 SP1 can be used together with SIMATIC PCS 7 V7.1+SP3 and SIMATIC PCS 7 V8.0 including Update 1. 11/2 Siemens ST PCS7 AO · 2013 SIMATIC powerrate comprises the following components: • Blocks for: - Acquiring and conditioning energy data - Load management (trend calculation, limit monitoring, connection/disconnection of consumers) - Batch-related consumption recording - Integration of measuring equipment and switches - Elementary functions such as time synchronization, data buffering, or data exchange with archives • Faceplates for: - Display and processing of the energy data - Display of results and for manual data input (configuration data or measured values) • Excel reports for: - Assignment of energy data to cost centers - Batch-related evaluation - Determination and display of load duration curve as the decision basis for load management • Data export to Excel © Siemens AG 2013 Power management SIMATIC powerrate for PCS 7: Energy data evaluation/energy management ■ Function Recording and conditioning energy data Data export and reporting The energy data of any PROFIBUS-compatible devices can be recorded by means of ready-to-use blocks, and archived for further use in the PCS 7 Tag Logging Archive. The data can be input to the function blocks in the form of counter pulses, counted values (absolute values or differences) or power values. Counted values can also be recorded manually. The blocks determine power averages from the recorded data as well as work values for a defined period. In addition, they determine a predicted power end value for each period by means of extrapolation. To simulate customized calculations, an example function (heat calculation) is available which can be adapted to customer requirements at any time over open interfaces. Batch-related consumption recording A batch comprises all units of a product that are produced in one production cycle, i.e. under identical conditions. The total energy consumption can be exactly determined for each batch as a result of batch-related consumption recording for five types of energy with up to 10 consumers each. Batch reports can be generated for analysis of the data (see data export and reporting). Integration of measuring devices 7KM PAC3200/PAC4200 The 7KM PAC3200/PAC4200 measuring devices can be integrated into the acquisition of energy data by means of DPV1 communication. Selected values measured by these units can be displayed, as well as messages (e.g. current, voltage or pulse frequency too high) generated from the digital status information. Integration of switches Switch integration via digital inputs/outputs (DI/DO) supports display of the switch status (on, off, tripped, unplugged). With the appropriate authorization, the switch can also be operated from the faceplate. Switching takes place in two steps (step 1: send switching command, step 2: confirm switching command). The switching command is only passed on to the switch following the confirmation. Displaying energy data The SIMATIC PCS 7 operator system has internal access to the archived energy data. In addition, it can be exported directly to Microsoft Excel and processed further in accordance with customer requirements. The following types of report can be generated in Microsoft Excel depending on the selected energy data: • Cost accounts report - Assignment of consumption to cost accounts - Calculation of costs based on defined tariffs - Output as table or diagram • Continuous curve - Evaluation of frequency of a particular mean supply value in a defined period - Fast recognition of brief supply peaks using this curve • Batch report - Assignment of consumption to batches - Presentation of data sorted according to batch name or time The generation of reports or exports can be time-controlled (daily, weekly, monthly) or triggered manually. Data access as well as report generation are also possible via a separate "office computer" with Microsoft Excel, i.e. separate from the operator system. The energy data is displayed as average supply values or work values for an interval. • Total value for the previous interval • Actual value of the current interval • Extrapolated value for the end of the current interval Representation of the load curve permits the evaluation and tabular presentation of archived energy data. Siemens ST PCS7 AO · 2013 11/3 11 © Siemens AG 2013 Power management SIMATIC powerrate for PCS 7: Energy data evaluation/energy management ■ Function (continued) Load management Supplementary function To avoid data loss in the event of a communication fault, the data are stored temporarily in a cyclic buffer of the SIMATIC PCS 7 automation system. To guarantee synchronism with the power supply utility, it is possible to evaluate its synchronization pulse. Note: The following block libraries (not in APL style) are supplied free of charge with the products "SIMATIC powerrate V4.0 SP1", "SIMATIC powerrate Upgrade V3.x to V4.0 SP1" and "SIMATIC powerrate Update V4.0 to V4.0 SP1": • Library 3VL/3WL for SIMATIC PCS 7 • Library 7KM PAC3200 for SIMATIC PCS 7 Further information on these block libraries is available in Chapter "Energy Management" in separate articles. ■ Technical specifications SIMATIC powerrate V4.0 SP1, system requirements If supply limits agreed in a contract are not observed (usually the 15-minute mean supply value for current), significantly higher supply prices or even penalty payments to the power supply utility may become necessary. Using cyclic trend calculations, the load management function of SIMATIC powerrate permits early recognition of limit violations, and signals these by means of warnings/alarms. Depending on the configuration, specific loads are switched off immediately in the event of an imminent limit violation. Should a limit violation nevertheless occur, the current load management data is archived for subsequent analysis. To avoid unnecessary switching operations, the load management function can be simply and conveniently adapted directly on the faceplate to the current process conditions by a wide range of parameters. The load management function can be used simultaneously for several different media (e.g. current, gas). 11 Loads distributed between different automation systems are linked into the load management by SIMATIC powerrate through AS-AS communication blocks. Load management is scalable according to the number of loads to be integrated or monitored (up to 10, 25, 50, 75 or 100 loads). 11/4 Siemens ST PCS7 AO · 2013 SIMATIC PCS 7 process control system V7.1+SP3 and V8.0 incl. Update 1 Automation systems (controller) Modular SIMATIC PCS 7 automation systems of the S7-400 range SIMATIC PCS 7 AS RTX and SIMATIC PCS 7 BOX RTX on basis of WinAC RTX 2010 controller SIMATIC powerrate reports Microsoft Excel 2003/2007/2010 © Siemens AG 2013 Power management SIMATIC powerrate for PCS 7: Energy data evaluation/energy management ■ Selection and ordering data SIMATIC powerrate V4.0 SP1 Energy management for SIMATIC PCS 7 V8.0 including Update 1 and V7.1+SP3 Engineering and runtime software, software class A, 2 languages (English, German), single license for one installation, with Order No. 6AV6 372-1DE04-0AX0 Order No. • Runtime license for any number of automation systems SIMATIC powerrate Upgrade V3.x to V4.0 SP1 Energy management for SIMATIC PCS 7 V8.0 including Update 1 and V7.1+SP3 Engineering and runtime software, software class A, 2 languages (English, German), single license for one installation, with • License for one SIMATIC PCS 7 operator station of type Server or Single Station1) • WinCC/User Archives license for load management and batchbased energy measurement • Runtime license for any number of automation systems Delivery package: Software and electronic documentation on DVD2), licenses (Certificate of License and License Key on USB stick) Delivery package: Software and electronic documentation on DVD2), licenses (Certificate of License and License Key on USB stick) • License for one SIMATIC PCS 7 operator station of type Server or Single Station1) • WinCC/User Archives license for load management and batchbased energy measurement SIMATIC powerrate trial license V4.0 SP1, 30 days Energy management for SIMATIC PCS 7 V8.0 including Update 1 and V7.1+SP3 Engineering and runtime software, software class A, 2 languages (English, German) 6AV6 372-1DE04-0AX7 Delivery package: Software and electronic documentation on DVD SIMATIC powerrate Update V4.0 to V4.0 SP1 Energy management for SIMATIC PCS 7 V8.0 including Update 1 and V7.1+SP3 6AV6 372-1DE04-0AX4 6AV6 372-1DE04-0AX3 Engineering and runtime software, software class A, 2 languages (English, German) Use only possible together with valid license SIMATIC powerrate V4.0 Delivery package: Software and electronic documentation on DVD2) 1) An additional SIMATIC PCS 7 powerrate license is required for each further SIMATIC PCS 7 operator station of type Server or Single Station; SIMATIC PCS 7 OS clients do not require a SIMATIC powerrate license. 2) Block libraries 7KM PAC3200 for SIMATIC PCS 7 and 3VL/3WL for SIMATIC PCS 7 are supplied free of charge. ■ More information Additional general information is available on the Internet at: www.siemens.com/simatic-pcs7/energy-management Information on the use of SIMATIC powerrate can be found at: http://support.automation.siemens.com/WW/view/en/48204134/ 133200 11 Siemens ST PCS7 AO · 2013 11/5 © Siemens AG 2013 Power management WinCC/B.Data ■ Overview PCS 7 Add-on fit for SIMATIC PCS 7 V8 SIMATIC B.Data V5.3 energy management system With SIMATIC B.Data, a modular, non-industry-specific energy management and operating information system is available for industrial firms. Energy management – Company portal WinCC 11 Automation field level Energy planning and procurement Energy controlling Energy purchase Purchase support Scenario calculator Emission CO2 emission monitoring Wastewater disposal Forecast Energy forecast Budget planning Energy accounting Cost center allocation Evaluation/invoicing Monitoring and reporting Connection of external systems Facility management ERP (e.g. SAP R/3) Maintenance management Energy reporting system Analysis and reporting Workflow system Intranet/Internet viewer Energy schedule Energy purchase schedule Specifications for Load management Energy and material balance KPI calculation Production allocation Fault/alarm management Alarms/messages Remote alarms (text message) Operation and control system Central detection Plant visualization Data processing and archiving Interfaces to lower-level systems Meters/ measuring devices Process control/ building management systems PLCs Load management Load shedding Load control Circuitbreakers Mobile data acquisition G_ST80_XX_00379 B.Data ■ Benefits The option SIMATIC B.Data forms the basis of a cost-effective energy management system for reducing energy costs and increasing energy efficiency, and it confers the following immediate benefits: 7 It creates company-wide transparency, thanks to continuous energy balancing and materials balancing for the power generation systems and loads 7 It allows energy costs to be allocated according to the costsby-cause principle and permits transfer to the billing system (e.g. SAP R/3 CO) 7 It generates characteristic values for well-informed suggestions for increasing the efficiency of power generation systems and loads 7 It provides planning reliability thanks to production-related load and demand forecasts 11/6 Siemens ST PCS7 AO · 2013 7 It supports purchasing with cost-optimized energy procurement 7 It fulfills the legal obligations for monitoring and reporting on greenhouse gas emissions (CO2 emissions) 7 It relieves personnel of extra work through automatically updating internal and external energy reports 7 It supports customers in the continuous improvement of energy efficiency (e.g. ISO 50001) by integrated project management for energy efficiency measures © Siemens AG 2013 Power management WinCC/B.Data ■ Design SIMATIC B.Data V5.3 Basic System The B.Data Basic System is available in variants for 100, 500, 1 000 and 30 000 tags and comprises the following components: • A B.Data acquisition component (WinCC, OPC, etc.) • A B.Data Client • B.Data Mobile • ERP interface • Reporting, Trender, Visu, document management, Matrix, KPI, Profile SIMATIC B.Data V5.3 Software Update Service (SUS) For each B.Data Basic System there is a corresponding SUS (Software Update Service), which is dependent on the number of tags. The SUS is valid for 1 year. The contract is automatically extended by 1 more year unless canceled 3 months prior to expiration. SIMATIC B.Data V5.3 Expansions The scope of B.Data can be extended by purchasing add-on packages: • B.Data V5.3 Web Server • B.Data V5.3 Client • B.Data V5.3 Energy Forecasting and Planning • B.Data V5.3 Acquisition Component Energy and material balance Freely parameterizable balancing of the energy flows of various media such as electricity, heat, gas, steam, and emissions (CO2) in the B.Data Plant Explorer • Calculation of characteristic values (KPIs, efficiency coefficients, etc.) with direct reference to production (batches, quantities, etc.). ■ Function Acquisition and pre-processing of energy and operating data from WinCC • In addition to an interface to WinCC, SIMATIC B.Data also offers the latest interface standards such as OPC, ODBC, ASCII, or XML • Preprocessing of energy data in a real-time calculation core that can be freely modeled including a formula editor for defining and configuring new calculation functions (heat calculations for boilers, quality for cogeneration plants, etc.) • B.Data Mobile for mobile recording of energy data including route planning for meter reading operations • Management and analysis of energy data • Automatic plausibility check and generation of simulated values • Long-term archive with versioning, compression and consolidation functions • Measured value editor for entering and processing energy and operating values • Trender for presenting up-to-date (online) and historical load curves (trends), also for setpoint/actual value analyses • Energy management dashboards for creating cross-company transparency through visualization of parameters and display of Sankey diagrams. 11 Energy accounting (costs and revenue accounting) Calculation and allocation/assignment of energy costs to plants and/or customers/cost units in accordance with the costs-bycause principle. The bottom up (measurement) and top down (allocation) procedures are supported here • Flexible modeling of the hierarchic accounting structures in the Plant Explorer • Tariff allocation of quantities, flexible price assessment with tariff and price time series • Transfer of costs/revenues to the ERP system (e.g. SAP R/3 CO) Siemens ST PCS7 AO · 2013 11/7 © Siemens AG 2013 Power management WinCC/B.Data ■ Function (continued) 90% Consumption area (e.g.: Building 1) 20% Consumption area (e.g.: Building 2) 1 ... n 75% 80% Factors are based on: • Numbers of employees • Area data • Allocation formula • etc. 100% Distribution ensured 25% Counter 1 Counter 3 Counter 2 G_ST80_XX_00380 Accounting area (e.g. Cost center) Losses 10% ■ Selection and ordering data Energy planning • Generation of requirement forecasts based on production-dependent factors (production planning) and basic load profiles (typical days) Energy reporting • Generation of energy schedules for registering with the energy suppliers. Energy reporting • Freely parameterizable report generator for creating balances, protocols, shift logs, bills • Fully automated reporting with task management, e-mail dispatch and document management • B.Data Intranet/Internet viewer (web client) for company-wide viewing of reports and results • Information about discrepancies from specified parameters through KPI warning system ■ Technical specifications SIMATIC B.Data V5.3 2) Operating system • Windows Server 2003 SP2 32 bit Eng./Ger. • Windows Server 2008 Std. Edition 32 bit Eng./Ger. • Windows Server 2008 R2 Eng./Ger. • Windows XP Professional SP3 32 bit Eng./Ger. 11 • Windows 7 Professional/Ultimate 32 bit/64 bit Eng./Ger. • Minimum of 2 GB RAM Interface In addition to an interface to WinCC, B.Data also offers the latest interface standards, such as OPC, ODBC, ASCII and XML. WinCC versions 1) • SIMATIC WinCC V7.0 SP3 • SIMATIC WinCC RT Professional V11 SP2 Update 2 PCS 7 versions 3) • SIMATIC PCS 7 V8.0 Update 1 1) If an acquisition computer is installed on a WinCC system, these requirements must also be complied with. 2) The SIMATIC B.Data V5.3 Basic System is delivered with an Oracle Database Standard Edition Embedded. For larger quantity frameworks (as of 250 million stored measured values), you need Oracle Database Enterprise Edition with Partitioning Option, which must be ordered separately from Oracle. 3) The SIMATIC B.Data system for connection to the PCS 7 must always be installed on a separate PC. 11/8 Siemens ST PCS7 AO · 2013 Order No. SIMATIC B.Data V5.3 Basic System In the basic system of B.Data, the following components are already included: One B.Data acquisition component (WinCC, OPC, etc.), 1 B.Data client, B.Data Data Mobile, ERP interface, Reporting, Trender, Visu, document management, Matrix, KPI, Profile • Basic system, 100 tags1) • SUS for 100 tags2) • Basic system, 500 tags1) • SUS for 500 tags2) • Basic system, 1 000 tags1) • SUS for 1 000 tags2) • Basic system, 30 000 tags1) • SUS for 30 000 tags2) SIMATIC B.Data V5.3 PowerPack • Basic system, PowerPack 1) Tag upgrade by 1 level • SUS and support contract for PowerPack 2) 6AV6 372-1DF05-3AX0 6AV6 372-1DF00-0AL1 6AV6 372-1DF05-3BX0 6AV6 372-1DF00-0BL1 6AV6 372-1DF05-3CX0 6AV6 372-1DF00-0CL1 6AV6 372-1DF05-3DX0 6AV6 372-1DF00-0DL1 6AV6 372-1DF05-3XX0 6AV6 372-1DF00-0XL1 SIMATIC B.Data V5.3 Trial License Basic system, 90 days 6AV6 372-1DF15-3AX0 SIMATIC B.Data V5 expansions3) The functional scope of B.Data can be expanded with the following packages. SIMATIC B.Data V5.3 Web Server • incl. 3 web clients • incl. 20 web clients 6AV6 372-1DF25-2AX0 6AV6 372-1DF25-2BX0 SIMATIC B.Data V5.3 Client 6AV6 372-1DF35-2AX0 SIMATIC B.Data V5.3 Prognosis & Planning 6AV6 372-1DF45-2AX0 SIMATIC B.Data V5.3 Acquisition Component 6AV6 372-1DF55-2AX0 SIMATIC B.Data V5.3 Upgrades • SIMATIC B.Data V5.3 100 tags, upgrade V5.2 -> V5.34) • SIMATIC B.Data V5.3 500 tags, upgrade V5.2 -> V5.34) • SIMATIC B.Data V5.3 1 000 tags, upgrade V5.2 -> V5.34) • SIMATIC B.Data V5.3 30 000 tags, upgrade V5.2 -> V5.34) 6AV6 372-1DF05-3AX4 6AV6 372-1DF05-3BX4 6AV6 372-1DF05-3CX4 6AV6 372-1DF05-3DX4 1) The SIMATIC B.Data V5.3 Basic System is delivered with an Oracle Database Standard Edition Embedded. For larger quantity frameworks (as of approx. 250 million stored measured values), you need Oracle Database Enterprise Edition with Partitioning Option, which must be ordered separately from Oracle. 2) The SUS contract runs for 1 year. The contract is automatically extended by a further year unless canceled 3 months prior to expiration. 3) B.Data expansions can also be used with B.Data V5.2 (SP1). 4) The upgrades are delivered without Oracle Database Standard Edition Embedded. ■ More information Additional information is available on the Internet at: www.siemens.com/simatic-bdata © Siemens AG 2013 Power management Library 3WL/3VL for SIMATIC PCS 7 ■ Overview PCS 7 Add-on ■ Function fit for SIMATIC PCS 7 V8 • Full integration of the circuit-breakers into the SIMATIC PCS 7 process control system using PROFIBUS DPV1 • Remote switching and monitoring • Read-out of maintenance information • Automatic information in event of overload, short-circuit or fault • Read-out and display of device data • Limit monitoring by the driver block • Resetting of values on the device (min./max. values) ■ Selection and ordering data Library 3WL/3VL for SIMATIC PCS 7 Seamless integration of the 3WL and 3VL circuit-breakers into the SIMATIC PCS 7 process control system is possible with the Library 3WL/3VL for SIMATIC PCS 7. The library comprises a driver block, a diagnostics block, and the faceplates. The blocks executed in the CPUs of the automation systems supply the faceplates in the user interface of the operator stations with current, power and energy values, generate messages, and establish the link to the SIMATIC PCS 7 Maintenance Station. Faceplates The faceplates serve as the user interface for operation and monitoring of the 3WL/3VL circuit-breakers on the operator station of the process control system. They allow simple display and operation of the 3WL/3VL circuit-breakers as SIMATIC PCS 7 objects. The system becomes more transparent when the Library 3WL/ 3VL for SIMATIC PCS 7 is used. Critical plant statuses can be detected rapidly, and unnecessary costs resulting from failures are avoided. This enhances long-term plant availability. Note: The Library 3WL/3VL V1.2 can be used together with SIMATIC PCS 7 V8.0 and V7.1. It supports all operating systems of these system versions. Library 3WL/3VL V1.2 AS blocks and faceplates for integration of 3WL/3VL circuit-breakers into SIMATIC PCS 7 V7.1 and V8.0, electronic documentation as well as: • Engineering license for one engineering station • Runtime license for one automation system 3ZS2 782-1CC10-0YG0 Engineering and runtime software, software class A, 2 languages (English, German), single license for one installation Delivery package: software and electronic documentation on CD, engineering and runtime licenses as certificate of license AS runtime license for Library 3WL/3VL V1.2 For one automation system each (Library 3WL/3VL required) 3ZS2 782-1CC10-6YH0 Runtime software, software class A, 2 languages (English, German), single license for one installation Delivery package: runtime license as certificate of license without software or documentation ■ More information Siemens AG Infrastructure & Cities Sector Low and Medium Voltage Division Low Voltage Nuremberg/Germany 11 Tel.: +49 (911) 895 – 7222 Fax: +49 (911) 895 - 7223 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.com/lowvoltage Siemens ST PCS7 AO · 2013 11/9 © Siemens AG 2013 Power management Library 7KM PAC3200 for SIMATIC PCS 7 ■ Overview ■ Function PCS 7 Add-on fit for SIMATIC PCS 7 V8 • Full integration of measuring instruments 7KM PAC3200 and 7KM PAC4200 into the SIMATIC PCS 7 process control system • Cyclic connection via PROFIBUS DP for monitoring and control tasks • Acyclic connection via PROFIBUS DPV1 for visualization tasks and acquisition of energy data • Support of 7KM PAC4200 corresponding to scope of functions of 7KM PAC3200 • Read-out and display of device data • Input of limits for monitoring by the driver block • Resetting of values on the device (min./max. values) ■ Selection and ordering data Order No. Library 7KM PAC3200for SIMATIC PCS 7 Library 7KM PAC3200 V1.2 AS blocks and faceplates for integration of measuring instruments 7KM PAC3200 and 7KM PAC4200 into SIMATIC PCS 7 V7.1 and V8.0, electronic documentation as well as: • Engineering license for one engineering station • Runtime license for one automation system The Library 7KM PAC3200 for SIMATIC PCS 7 is a block library for the measuring instruments 7KM PAC3200 and 7KM PAC4200. It allows seamless integration of the measuring instruments operated on the PROFIBUS DP into the SIMATIC PCS 7 process control system. The measuring instrument 7KM PAC4200 if supported by the functionalities of the PAC3200. The Library 7KM PAC3200 comprises a driver block, a diagnostics block, and the faceplates. The blocks executed in the CPUs of the automation systems supply the faceplates in the user interface of the operator stations with energy data, generate messages, and establish the link to the SIMATIC PCS 7 Maintenance Station. Faceplates 11 The faceplates serve as the HMI for operation and monitoring of the measuring instruments. They enable technologically relevant values and functions of the measuring instruments 7KM PAC3200 and 7KM PAC4200 to be displayed and accessed on the operator station of the process control system. All important electric variables of the 7KM PAC3200 and 7KM PAC4200 are visualized on the SIMATIC PCS 7 operator station via the faceplates, and their limits monitored. Limit violations generate messages which are passed on to the signaling system of the operator system. Display of values via the faceplates and transfer of inputs to the measuring instruments 7KM PAC3200 and 7KM PAC4200 are carried out over bidirectional communication links on the system side between the faceplates and the blocks, and between the blocks and the measuring instrument. The measuring instruments 7KM PAC3200 and 7KM PAC4200 are thus integral components of SIMATIC PCS 7. Note: 11/10 Engineering and runtime software, software class A, 2 languages (English, German), single license for one installation Delivery package: Software and electronic documentation on CD, engineering and runtime licenses as certificate of license AS runtime license for Library 7KM PAC3200 V1.2 For one automation system each (Library 7KM PAC3200 required) Siemens ST PCS7 AO · 2013 3ZS2 781-1CC10-6YH0 Runtime software, software class A, 2 languages (English, German), single license for one installation Delivery package: Runtime license as certificate of license without software or documentation Note: The Library 7KM PAC3200 for SIMATIC PCS 7 is not available as a stand-alone product. It is also integrated in the SIMATIC PCS 7 add-on product "SIMATIC powerrate". ■ More information Siemens AG Infrastructure & Cities Sector Low and Medium Voltage Division Low Voltage Nuremberg/Germany Tel.: +49 (911) 895 – 7222 Fax: +49 (911) 895 - 7223 E-mail: [email protected] Additional information is available on the Internet at: www.siemens.com/lowvoltage The Library 7KM PAC3200 V1.2 can be used together with SIMATIC PCS 7 V8.0 and V7.1. It supports all operating systems of these system versions. With SIMATIC PCS 7 V7.1+SP2 and higher, the blocks also execute in automation systems with the WinAC RTX 2010 software controller. 3ZS2 781-1CC11-0YG0 © Siemens AG 2013 Architecture and configuration 12 12/2 Automation firewall 12/5 Cabinets for SIMATIC PCS 7 12/9 SICLOCK time synchronization Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Architecture and configuration Automation firewall ■ Overview PCS 7 Add-on fit for SIMATIC PCS 7 V8 Internet Office CAS Web Client ERP Data Monitor Domain Controller Automation Firewall 1000 ktGG Virus scan server WSUS Server Central archive server Web Server/ OpenPCS 7 lSGvGshu Automation Firewall 1000 Automation Firewall 200 Production network 1 Production network 2 {G {G OS Client Engineering Station SCALANCE S602 Production network 3 OS Client Domain Controller 12 wG wG SCALANCE S612 G_ST80_XX_00500 VPN tunnel The availability and security of production plants is of great importance in industrial environments. Integration of the process control system into the corporate network increases the risk of damage by viruses or malware. 12/2 Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Architecture and configuration Automation firewall ■ Overview (continued) In order to avoid production failures and downtimes, data traffic between the networks must be checked, analyzed and selectively approved without impairing the function of the process control system. Only in this manner is it possible to provide optimum protection for the plant without impairing productivity. Firewalls with supplementary services are most appropriate for this. The Automation Firewall from Siemens is a tested and validated standard firewall available in two performance classes (Automation Firewall 200 and 1000). It has been tuned for use with SIMATIC PCS 7 and WinCC. The Automation Firewall works excellently with SIMATIC NET communication products. It features comprehensive hardware and software functions for SIMATIC PCS 7 and WinCC projects, e.g.: • Stateful Inspection packet filter • Application layer firewall • VPN gateway • Antivirus scanning and IDS • URL filtering • Web proxy The value of the Automation Firewall is increased even further by integrated services, e.g.: • Hotline support • Replacement service • Software Update Service Depending on the plant configuration and size, the Automation Firewall is preferably used as: • Three-homed firewall for small to medium-sized plants with minimal perimeter network • Front and back firewall for maximum protection in larger plants with extensive perimeter network Note: Use of the Automation Firewall 200 or 1000 is independent of the version of the SIMATIC PCS 7 process control system on which the process control installation is based. ■ Design Automation Firewall 200/1000 Automation Firewall 200 and 1000 differ as follows: Type Automation Firewall 200 Automation Firewall 1000 Position Entry-level version for small plants, including TMG 2010 license QuadCore version with remote management functionality for medium-sized and large plants, including TMG 2010 license Form factor 19”, 1 HM 19”, 1 HM Data volume Low Medium to large Frequency of data transfer Sporadic Continuous Additional utilities supported WSUS, antivirus server in the perimeter network Data Historian, Web server, OPC server in the perimeter network Drives 1 x SATA 24x7 2 x SATA2 RAID1 Ethernet interfaces 4 x 10/100/1000 NIC 4 x 10/100/1000 NIC Additional services • Customer-specific firewall solutions for special requirements • Integration of firewalls in customer systems - Planning and implementation of firewall configuration - Integration and startup - Preparation of customer documentation • Continuous monitoring of functionality and up-to-dateness of firewall solution including reports • Services for signaling critical statuses in the system network 12 Siemens ST PCS7 AO · 2013 12/3 © Siemens AG 2013 Architecture and configuration Automation firewall ■ Selection and ordering data Order No. Automation Firewall 200 including standard service contract for 1 year CPU Intel Dual Core 64 bit, 2 GB RAM, 1 x HDD, 4 x 10/100/ 1000 NIC, Microsoft Forefront Threat Management Gateway 2010 (25user license) 9AS1 424-1AA11-1AA1 Service contract for Automation Firewall 200, contract extension for 1 year Note: Max. total term 5 years 9AS1 424-1AA61-1AA1 Automation Firewall 1000 including standard service contract for 1 year Intel QuadCore XEON CPU, 4 GB RAM, 2 x HDD RAID1, 4 x 10/100/ 1000 NIC, remote management, Microsoft Forefront Threat Management Gateway 2010 (25-user license) 9AS1 424-1AB11-1AA1 Service contract for Automation Firewall 1000, contract extension for 1 year Note: Max. total term 5 years 9AS1 424-1AB61-1AA1 Integration of firewall into customer system 8-hour service for planning and implementation of firewall configuration, integration and startup, preparation of customer documentation Note: Additional travel times and costs will be charged for on-site visits. 9AS1 424-2AB11-1AA1 Individual firewall solutions / managed services On request From the following address you can obtain support in selecting the firewall as well as information on integrated and additional services: Customer Service Christoph Hampel Tel.: +49 9131 7 33810 or Tel.: +49 721 595 3669 E-mail: [email protected] 12 12/4 ■ More information Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Architecture and configuration Cabinets for SIMATIC PCS 7 ■ Overview PCS 7 Add-on ■ Function fit for SIMATIC PCS 7 V8 The cabinet construction described here permits the configuration of tailor-made cabinets for the SIMATIC PCS 7 automation systems AS 41x and for the ET 200M distributed I/O. Due to their modularity, the cabinets can very easily be adapted to different sizes and types of plant (batch or continuous process plants). The preferred basic cabinet is the Siemens 8MC standard cabinet with IP40 degree of protection (closed) or IP20 degree of protection (with air slits in the door and perforated roof). If required, IP55 can be achieved by using an upgrade kit. Fully assembled AS 41x system units and ET 200M I/O units are offered with all necessary accessories to supplement this basic cabinet. High flexibility • Future-proof due to universal, system-neutral modules • Flexible adjustment to the application in question thanks to modular cabinet construction • Basic and expansion cabinets based on the same module inventory • Up to 4 system or 6 I/O units can be fitted in one cabinet. Installation on both sides is possible given a cabinet depth of 600 mm • System and I/O units can be combined in the cabinet • Side or partition walls may be selected according to the application • Modular cabinets can be bolted together; combinations into double cabinets or cabinet rows are possible • All installation, commissioning, servicing and repair operations may be carried out from the front side of the cabinet • Design supports correct handling when replacing modules • Infeed line may optionally be built with circuit breakers (Siemens) or circuit breakers for plugging into a base (ETA with monitoring contact) • Wiring for the electronics supply and the load power supply for the I/O modules • Wiring of the PROFIBUS DP from the system unit to the ET 200M I/O units and to the OLM or OSM using copper or fiber-optic cables Ex(i)-specific requirements taken into consideration • The design of the system and I/O units permits a cabinet construction that meets Ex(i)-specific requirements (blue cable ducts, bus module covers, isolating elements). CE conformity • The cabinets are built under consideration of BGV A3 guidelines. • They conform with CE directives and comply with the guidelines for electromagnetic compatibility specified in the German EMC Act. Note: The SIMATIC PCS 7 cabinet construction according to the description is suitable for SIMATIC PCS 7 V7 and V8. 12 Siemens ST PCS7 AO · 2013 12/5 © Siemens AG 2013 Architecture and configuration Cabinets for SIMATIC PCS 7 ■ Selection and ordering data Order No. 8MC cabinet Order No. 8MC cabinet 6DL2 800- ■■■■■ - ■■■■ Cabinet design Cabinet with 19" mounting frame, crane lifting lugs, twist lever handle, pocket for circuit diagram Dimensions H x W x D in mm, degree of protection: • Cabinet with single-wing door, 2 000 x 800 x 400, IP40 • Cabinet with single-wing door, 2 000 x 800 x 400, IP20 • Cabinet with single-wing door, 2 000 x 800 x 600, IP40 • Cabinet with single-wing door, 2 000 x 800 x 600, IP20 • Cabinet with double-wing door, 2 000 x 1 000 x 400, IP40 • Cabinet with double-wing doors on front and back, 2 000 x 1 000 x 600, IP40 • Cabinet with single-wing door, 2 200 x 800 x 400, IP20 • Cabinet with single-wing doors on front and back, 2 200 x 800 x 600, IP20 Plinth Dimensions W x D in mm: • Without base • Base 800 x 400 • Base 800 x 600 Infeed • No infeed 0 X • 24 V DC with - 4 x Siemens circuit breakers 1 A 1 A - 8 x Siemens circuit breakers 1 B 1 B - 12 x Siemens circuit breakers 1 C - 6 x ICE circuit breakers with aux. contact 1 E - 12 x ICE circuit breakers with aux. contact 1 H 2 A 2 B • 24 V DC redundant with 3 E 4 G 5 J 6 K - 4 x Siemens circuit breakers 2 A - 8 x Siemens circuit breakers 2 B - 12 x Siemens circuit breakers 2 C - 6 x ICE circuit breakers with aux. contact 2 E - 12 x ICE circuit breakers with aux. contact 2 H • 120/230 V AC with X A B • Base 1000 x 400 C • Base 1000 x 600 D - 4 x Siemens circuit breakers 3 A - 8 x Siemens circuit breakers 3 B - 12 x Siemens circuit breakers 3 C - 6 x ICE circuit breakers with aux. contact 3 E - 12 x ICE circuit breakers with aux. contact 3 H Installation of system unit • Without central unit X • 1 x bundle with UR2 or UR1 A • 2 x bundle with UR2 or UR1 B • 3 x bundle with UR2 or UR1 C 1 • 4 x bundle with UR2 or UR1 D - 2 000 x 600 3 • 1 x bundle with UR2 or UR1, with OLM or OSM E - 2 200 x 400 5 • 2 x bundle with UR2 or UR1, with OLM or OSM F - 2 200 x 600 7 • 3 x bundle with UR2 or UR1, with OLM or OSM G • 4 x bundle with UR2 or UR1, with OLM or OSM H Side wall Dimensions H x D in mm: • Without side panel 0 • Side panel on left or right - 2 000 x 400 • Side panel on left and right 12 6DL2 800- ■■■■■ - ■■■■ - 2 000 x 400 2 - 2 000 x 600 4 Documentation • Without documentation - 2 200 x 400 6 • General description of cabinet - 2 200 x 600 8 I&C monitoring • Without I&C monitoring • Monitoring of the circuit-breakers (only for in-circuit emulator), display on cabinet lamp • Monitoring of circuit-breaker (only with ICE), overheating, door monitoring, OLM, display by means of cabinet lamp and DI module 6ES74217DH00-0BA0 (DI module must be ordered separately) 0 1 2 - German 1 - English 2 • Cabinet-specific documentation with AutoCAD drawings - German - English • General description and cabinet-specific documentation with AutoCAD drawings - German - English 12/6 Siemens ST PCS7 AO · 2013 0 3 4 5 6 © Siemens AG 2013 Architecture and configuration Cabinets for SIMATIC PCS 7 ■ Selection and ordering data (continued) Order No. ET 200M I/O station 6DL2 802-..... ■ ■ ■ ■ ■ PROFIBUS • PROFIBUS DP in copper, for IM 153-1 and IM 153-2 1 • PROFIBUS DP in copper, for redundant IM 153-2 2 • PROFIBUS DP in fiber-optic, for IM 153-1 and IM 153-2 3 • PROFIBUS DP in fiber-optic, for redundant IM 153-2 4 ET rack • ET rack for non-redundant IM 153 without individual protection of the I/O modules, with only one circuit-breaker for IM 153 and load power supply or one circuit-breaker for IM 153 and one circuit-breaker for load power supply (circuit breakers must be ordered together with cabinet 6DL2800...) A A • ET rack for redundant IM 153 without individual protection of the I/O modules, with one circuit-breaker for first IM 153, one circuit-breaker for second IM 153 and one circuit-breaker for load power supply (circuit breakers must be ordered together with cabinet 6DL2800...) B A • ET rack for redundant IM 153 without individual protection of the I/O modules, with one circuit breaker for first IM 153 and one circuit breaker for second IM 153. The load power supply is provided via a diode module from the circuit breakers of the IM (circuit breakers must be ordered together with cabinet 6DL2800...) C A • ET rack 230 V AC for redundant IM 153 without individual protection of the I/O modules, with one circuit breaker for first 230 V PS and one circuit breaker for second 230 V PS. The load power supply is provided via a diode module from the two PS (circuit breakers must be ordered together with cabinet 6DL2800...) D A • ET rack for non-redundant IM 153 with individual protection of the I/O modules, with only one circuit breaker for IM 153 and load power supply or one circuit breaker for IM 153 and one circuit breaker for load power supply (circuit breakers must be ordered together with cabinet 6DL2800...) A B • ET rack for redundant IM 153 with individual protection of the I/O modules, with one circuit breaker for first IM 153, one circuit breaker for second IM 153 and one circuit breaker for load power supply (circuit breakers must be ordered together with cabinet 6DL2800...) B B • ET rack for redundant IM 153 with individual protection of the I/O modules, with one circuit breaker for first IM 153 and one circuit breaker for second IM 153. The load power supply is provided via a diode module from the circuit breakers of the IM (circuit breakers must be ordered together with cabinet 6DL2800...) C B • ET rack 230 V AC for redundant IM 153 with individual protection of the I/O modules, with one circuit breaker for first 230 V PS and one circuit breaker for second 230 V PS. The load power supply is provided via a diode module from the two PS (circuit breakers must be ordered together with cabinet 6DL2800...) D B 12 Siemens ST PCS7 AO · 2013 12/7 © Siemens AG 2013 Architecture and configuration Cabinets for SIMATIC PCS 7 ■ Selection and ordering data (continued) Order No. ET 200M I/O station 6DL2 802-..... ■ ■ ■ ■ ■ Installation of the I/O modules • Without installation of the I/O modules 0 • Without installation of the I/O modules, prepared with isolating element and partition in cable duct for Ex(i) design • Installation of 4 I/O modules, connect L+ and M- supply, test and configure modules • Installation of 8 I/O modules, connect L+ and M- supply, test and configure modules • Installation of 4 I/O modules for Ex(i), connect L+ and M- supply, test and configure modules, cable guide for L+ I/O module supply, isolating element between nonhazardous and hazardous areas, partition in cable duct, cable duct marked in blue • Installation of 8 I/O modules for Ex(i), connect L+ and M- supply, test and configure modules, cable guide for L+ I/O module supply, isolating element between non-hazardous and hazardous areas, partition in cable duct, cable duct marked in blue 2 3 4 5 Tests • Without testing of I/O functions 0 • Function testing of inputs/outputs for 4 modules 1 • Function testing of inputs/outputs for 8 modules 2 DP/PA coupler • Installation, wiring and bus connection of up to 4 DP/PA couplers on 19" DIN rail without individual protection of the I/O modules Order DP bus connectors separately according to number of couplers • Installation, wiring and bus connection of up to 4 DP/PA couplers on 19" DIN rail with individual protection of the I/O modules Order DP bus connectors separately according to number of couplers • Installation, wiring and bus connection of IM 157 and up to 4 DP/PA links/couplers on 19" DIN rail with individual protection of the I/O modules Order bus modules separately for hot swapping function. ■ Options ■ More information Project-specific cabinets Apart from the standardized cabinets, we manufacture cabinets for specific projects or customer requirements: • Cabinets of different sizes and designs • Small wall-mounted enclosure for distributed configuration • Outdoor units with air conditioning All are offered optionally as Ex versions and with non-standard degrees of protection such as NEMA 4x or IP66. 12/8 Siemens ST PCS7 AO · 2013 6DL2 803-1AA00 6DL2 803-1AA10 PA link • Installation, wiring and bus connection of IM 157 and up to 4 DP/PA links/couplers on 19" DIN rail without individual protection of the I/O modules Order bus modules separately for hot swapping function. 12 1 Siemens AG Industry Sector Industry Automation Division Control Components and Systems Engineering Karlsruhe Tel.: +49 721 595-3776 Fax: +49 721 595-6525 E-mail: [email protected] 6DL2 803-1BA00 6DL2 803-1BA10 © Siemens AG 2013 Architecture and configuration SICLOCK time synchronization ■ Overview PCS 7 Add-on fit for SIMATIC PCS 7 V8 • Small plants: For small to medium-sized plants, the PCS 7 Operator Station or the WinCC Station are used as the time master, connecting the corresponding DCF or GPS radio clock directly to the COM interface of the PC. An alternative to the PC solution is the option of synchronizing the plant over the NTP via the SICLOCK central plant clocks. The SICLOCK TC 100 is recommended for use with these small plants. • Stand-alone systems: For SIMATIC S7 controllers or small systems, e.g. for laboratory automation, SICLOCK DCFS7 is a low-cost alternative to DCF77 synchronization directly over an S7 digital input. ■ Design SICLOCK TC 400 and TC 100 are designed for mounting on a SIMATIC rail. Sets of materials for installation in 19-inch racks are also available. ■ Function Central plant clocks The SICLOCK TC 400 and SICLOCK TC 100 central plant clocks support the synchronization of CPs and PCs with the SIMATIC procedure as well as the NTP procedure over Industrial Ethernet. SICLOCK TC 400 • SICLOCK TC 400 and TC 100 central plant clock as the central component for time synchronization of a plant over Ethernet • SICLOCK TC 400 - Four independent Ethernet interfaces for supporting several Ethernet subnets - Redundancy options - Designed for PROFINET • SICLOCK TC 100 - An Ethernet interface - Designed for mini and small plants - Designed for PROFINET • GPS or DCF77 radio clocks for direct connection to PCs, SIMATIC S7 controllers, and to the SICLOCK TC 400 or TC 100 central plant clocks • Pulse converter for electrical and optical distribution and interface conversion • Complete packages for common applications ■ Application Time synchronization of all components plays an important part in the automation of production plants. The SICLOCK system is a parameterizable, modular system with perfectly matched components for the time synchronization of plants. GPS (worldwide) as well as DCF77 (Germany) can be used for external radio synchronization The modular SICLOCK system supports the time synchronization of an individual PLC through to the large plant with multiple redundancy. Time synchronization concepts The automation systems and operator stations of a SIMATIC PCS 7 plant or WinCC stations can be synchronized as follows with DCF77 or GPS time signals: • Large plants: for larger plants with many network stations and stringent requirements for timekeeping, the time synchronization is performed using a SICLOCK TC 400 central plant clock on the plant bus. SICLOCK TC 400 is used as a central plant clock for highly accurate timekeeping and distributes the time to all synchronized systems over Industrial Ethernet, as well as over three additional point-to-point connections with TTY/24 V and RS422/5 V. The devices are equipped with four independent Ethernet interfaces. This enables separate or redundant automation networks and I&C networks to be synchronized in parallel with just one device. Apart from the well-proven standard networks such as SIMATIC NET or NTP, TC 400 is also prepared for use in PROFINET. Interfaces, signal types, redundancy, etc. are parameterized over the Internet/HMI. The display of statuses on the device provides fast access to the operating status and any faults. SICLOCK TC 400 has interrupt capability and can be integrated into the I&C. SICLOCK TC 100 SICLOCK TC 100 is the "little sister" of the TC 400 and is used as a central plant clock for highly accurate time synchronization. It distributes the time to all systems to be synchronized over an Industrial Ethernet interface. Like the TC 400, the interfaces, signal types, redundancy, etc. are parameterized over the Internet/HMI. The display of statuses on the device provides fast access to the operating status and any faults. SICLOCK TC 100 has interrupt capability and can be integrated into the I&C. On failure of the antennas of radio clocks, the central plant clocks SICLOCK TC 400 and SICLOCK TC 100 continue to provide reliable clock control thanks to automatic changeover to highly accurate quartz operation. When the radio clock is returned to service, they accept the time signal without a time step. Siemens ST PCS7 AO · 2013 12/9 12 © Siemens AG 2013 Architecture and configuration SICLOCK time synchronization ■ Selection and ordering data Order No. SICLOCK TC 400 central plant clock DCF radio clocks SICLOCK TC 400 with GPS1000 antenna, complete package SICLOCK DCFRS, radio clock, industrial version 2XV9 450-2AR10 Package comprises • SICLOCK TC 400 Complete solution, e.g. for use in PCS 7 SICLOCK TC 400 with DCF77 antenna, complete package 2XV9 450-2AR20 • 1 m connecting cable mounted, extendable to 1 000 m • DCF77 receiving service for Windows SICLOCK DCFRS, radio clock for Windows • Active DCF77 antenna with TTY output (20 mA line current), antenna rack, and approx. 2 m connecting cable; extendable to max. 1 000 m • Junction box 2XV9 450-2AR01 SICLOCK TC 100 central plant clock SICLOCK TC 100 with GPS1000 antenna, complete package 2XV9 450-2AR50 Complete solution, e.g. for use in PCS 7 2XV9 450-2AR26 2XV9 450-1AR36 • SICLOCK DCFS7 receiving service (STEP 7 function block for integration in S7 software) Accessories for SICLOCK DCFS7 SICLOCK TC 100 central plant clock with Ethernet interface and DCFRS radio clock, industrial version; package comprises • SICLOCK TC 100 • Active DCF77 antenna with TTY output (20 mA line current), antenna frame, and approx. 2 m connecting cable. Extendable to max. 1000 m • Junction box 12/10 • DCF77 receiving service for Windows Low-cost solution for time synchronization of SIMATIC S7-300/400 over DCF77 over one digital input, package comprises • SICLOCK DCFRS, radio clock with RS232 output, 20 m connecting cable and mounting bracket • SICLOCK DCFS7 interface • SICLOCK GPS1000 system with antenna rack and approx. 2 m connecting cable; extendable to max. 1000 m. • Lightning protection for GPS SICLOCK TC 100 single device 2XV9 450-1AR14 DCF radio clock for the time synchronization of individual PCs over short distances, package comprises • Active DCF77 antennas with RS232 interface and mounting bracket • 20 m connecting cable, mounted SICLOCK DCFS7 Package comprises • SICLOCK TC 100 SICLOCK TC 100 with DCF77 antenna, complete package • Plug-in power supply • Two junction boxes SICLOCK TC 400 central plant clock with Ethernet interface + DCFRS radio clock, industrial version; package comprises • SICLOCK TC 400 SICLOCK TC 400 single device 2XV9 450-1AR21 DCF radio clock for time synchronization of individual PCs or servers in industrial environments with high levels of interference; distances of up to 1000 m are possible between the DCF radio clock and the PC, package comprises • Active DCF77 antenna with TTY output (20 mA line current) and antenna frame • TTY/RS232 converter • SICLOCK GPS1000 system with antenna rack and approx. 2 m connecting cable; extendable to max. 1000 m • Lightning protection for GPS 12 Order No. SICLOCK DCFS7 interface + receiving service 2XV9 450-1AR30 (STEP 7 function block for integration in S7 software) SICLOCK DCFS7 interface 2XV9 450-1AR35 SICLOCK DCFS7 receiving service 2XV9 450-1AR32 (STEP 7 function block for integration in S7 software) 2XV9 450-2AR22 Siemens ST PCS7 AO · 2013 © Siemens AG 2013 Architecture and configuration SICLOCK time synchronization ■ Ordering data Order No. GPS radio clocks GPS1000 + power supply, radio clock for Windows GPS radio clock for the time synchronization of PCs, programmable controllers, as well as the SICLOCK TC 400/TC 100 central plant clocks in industrial environments with high levels of interference with distances up to 1 000 m between the antenna and the device, package comprises • GPS1000 antenna head with antenna frame • GPS1000 power supply • Junction box • 5 m RS232 connecting cable • DCF77 receiving service for Windows Order No. Accessories 2XV9 450-1AR82 Kit for SICLOCK TC400 and TC100 • For 19" mounting frame Lightning protection for antenna cable • Lightning protection for TTY connecting cable (SICLOCK GPS1000/DCFRS industrial version) 2XV9 450-2AR81 2XV9 450-1AR83 Software SICLOCK DCF77 receiving service for Windows 2XV9 450-1AR28 Pulse converter SICLOCK EOPC Electrical/optical pulse converter for industrial applications with 32 fiberoptic cable outlets for transparent operation and pulse mode • SICLOCK EOPC 24 to 110 V DC • SICLOCK EOPC 90 to 230 V AC/DC 2XV9 450-1AR72 2XV9 450-1AR73 SICLOCK PCON Single-channel electrical/optical pulse converter for industrial applications • SICLOCK PCON 24 to 230 V AC/ DC, with multi-mode fiberglass connection, 820 nm SICLOCK DCFHF 2XV9 450-1AR63-1SA3 2XV9 450-1AR64 HF modulator for DCF77 signals for industrial applications ■ More information Support can be found at: www.siemens.com/simatic-net/ik-info You will find more information on the Internet at: www.siemens.com/siclock 12 Siemens ST PCS7 AO · 2013 12/11 © Siemens AG 2013 Architecture and configuration Notes 12 12/12 Siemens ST PCS7 AO · 2013 13 © Siemens AG 2013 Appendix 13/2 13/3 13/4 13/4 13/5 13/6 13/6 13/7 Partners at Industry Automation and Drive Technologies Siemens Solution Partner Automation Online Services Information and Ordering in the Internet and on DVD Information and Download Center Social Media, Mobile Media Industry Services Your machines and plant can do more – with Industry Services. Industry Services for the entire life cycle 13/11 Software Licenses 13/13 Index 13/14 Order No. Index 13/16 Conditions of sale and delivery Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Appendix Partners at Industry Automation and Drive Technologies At Siemens Industry Automation and Drive Technologies, more than 85 000 people are resolutely pursuing the same goal: longterm improvement of your competitive ability. We are committed to this goal. Thanks to our commitment, we continue to set new standards in automation and drive technology. In all industries – worldwide. At your service locally, around the globe for consulting, sales, training, service, support, spare parts ... on the entire Industry Automation and Drive Technologies range. Your personal contact can be found in our Contacts Database at: www.siemens.com/automation/partner You start by selecting a • Product group, • Country, • City, • Service. 13 13/2 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Appendix Partner at Industry Automation and Drive Technologies Siemens Solution Partner Automation ■ Overview Siemens Solution Partner Automation Solution Partner Finder Solution Partner: Highest quality - guaranteed The products and systems from Siemens Industry Automation and Drive Technologies offer the ideal platform for all automation applications. Under the name of Siemens Solution Partner Automation, selected system integrators around the world act as uniformly qualified solution providers for the Siemens range of products and services in the fields of automation and drives. Day after day, they utilize their qualified product and system know-how as well as their excellent industry expertise to your advantage – for all requirements. The partner emblem is the guarantee and indicator of proven quality. The basis for this are defined quality features that identify Solution Partners as reliable and competent solution providers: • Solution quality Always a good result with tried and tested solutions expertise. • Expert quality Certified technical competence ensures maximum efficiency. • Project quality With proven project experience straight to the target. • Portfolio quality Comprehensive portfolio for state-of-the-art solutions from a single source. The Siemens Solution Partner Program helps you to find the optimum partner for your specific requirements. Support is provided by the Solution Partner Finder, a comprehensive online platform that showcases the profiles of all our solution partners. You can convince yourself of the competence of the respective Solution Partner by means of the references provided. Various search criteria are available for this purpose. Once you have located a partner, you are only one small step away from contacting them. Find the right partner here for your specific task and convince yourself of the solution competence provided: www.siemens.com/automation/partnerfinder Additional information on the Siemens Solution Partner Program is available online at: www.siemens.com/automation/solutionpartner 13 Siemens ST PCS 7 AO · 2013 13/3 © Siemens AG 2013 Appendix Online Services Information and Ordering in the Internet and on DVD ■ Siemens Industry Automation and Drive Technologies in the WWW A detailed knowledge of the range of products and services available is essential when planning and configuring automation systems. It goes without saying that this information must always be fully up-to-date. Siemens Industry Automation and Drive Technologies has therefore built up a comprehensive range of information in the World Wide Web, which offers quick and easy access to all data required. Under the address www.siemens.com/industry you will find everything you need to know about products, systems and services. ■ Product Selection Using the Interactive Catalog CA 01 of Industry Detailed information together with convenient interactive functions: The interactive catalog CA 01 covers more than 80 000 products and thus provides a full summary of the Siemens Industry Automation and Drive Technologies product base. Here you will find everything that you need to solve tasks in the fields of automation, switchgear, installation and drives. All information is linked into a user interface which is easy to work with and intuitive. After selecting the product of your choice you can order at the press of a button, by fax or by online link. Information on the interactive catalog CA 01 can be found in the Internet under www.siemens.com/automation/ca01 or on DVD. ■ Easy Shopping with the Industry Mall The Industry Mall is the virtual department store of Siemens AG on the Internet. Here you have access to a huge range of products presented in electronic catalogs in an informative and attractive way. Data transfer via EDIFACT allows the whole procedure from selection through ordering to tracking of the order to be carried out online via the Internet. 13 Numerous functions are available to support you. For example, powerful search functions make it easy to find the required products, which can be immediately checked for availability. Customer-specific discounts and preparation of quotes can be carried out online as well as order tracking and tracing. Please visit the Industry Mall on the Internet under: www.siemens.com/industrymall 13/4 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Appendix Online Services Information and Download Center Social Media, Mobile Media ■ Downloading Catalogs In addition to numerous other useful documents, you can also find the catalogs listed on the back inside cover of this catalog in the Information and Download Center. Without having to register, you can download these catalogs in PDF format or increasingly as digital page-turning e-books. The filter dialog box above the first catalog displayed makes it possible to carry out targeted searches. If you enter “MD 3” for example, you will find both the MD 30.1 and MD 31.3 catalogs. If you enter “ST 70” both the ST 70 catalog and the associated news or add-ons are displayed. Visit us on the web at: www.siemens.com/automation/infocenter ■ Social Media Connect with Siemens through social media: visit our social networking sites for a wealth of useful information, demos on products and services, the opportunity to provide feedback, to exchange information and ideas with customers and other Siemens employees, and much, much more. Stay in the know and follow us on the ever-expanding global network of social media. Connect with Siemens Industry at our central access point: www.siemens.com/industry/socialmedia Or via our product pages at: www.siemens.com/automation or www.siemens.com/drives To find out more about Siemens' current social media activities visit us at: www.siemens.com/socialmedia ■ Mobile Media Discover the world of Siemens. We are also constantly expanding our offering of cross-platform apps for smartphones and tablets. You will find the current Siemens apps at the app store (iOS) or at Google Play (Android). The Siemens app, for example, tells you all about the history, latest developments and future plans of the company – with informative pictures, fascinating reports and the most recent press releases. Siemens ST PCS 7 AO · 2013 13/5 13 © Siemens AG 2013 Appendix Industry Services Your machines and plant can do more – with Industry Services. Whether it is production or process industry - in view of rising cost pressure, growing energy costs, and increasingly stringent environmental regulations, services for industry are a crucial competitive factor in manufacturing as well as in process industries. All over the world Siemens supports its customers with product, system, and application-related services throughout the entire life cycle of a plant. Right from the earliest stages of planning, engineering, and building, all the way to operation and modernization. These services enable customers to benefit from the Siemens experts’ unique technological and product knowledge and industry expertise. Thus downtimes are reduced and the utilization of resources is optimized. The bottom line: increased plant productivity, flexibility, and efficiency, plus reduced overall costs. Discover all advantages of our service portfolio: www.siemens.com/industry-services {GjGMGG lGz l GMG G lGz {GjGMGG lGz l GMG lGz t¡GM G v¡Gz Modernization Modernization Planning Planning Online Support Technical Support Spare Parts Repair Services Field Services Training Operation Operation {GjGMGG lGz Engineer Engineer & & Build Build l GMG lGz wGtGMGG jGt zG l GMGlG t¡GMGv¡Gz 13 G_DA65_EN_00270 Siemens supports its clients with technology based Services across a plants entire life cycle. 13/6 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Appendix Industry Services Industry Services for the entire life cycle Online Support Online support is a comprehensive information system for all questions relating to products, systems, and solutions that Siemens has developed for industry over time. With more than 300,000 documents, examples and tools, it offers users of automation and drive technology a way to quickly find up-to-date information. The 24-hour service enables direct, central access to detailed product information as well as numerous solution examples for programming, configuration and application. The content, in six languages, is increasingly multimediabased – and now also available as a mobile app. Online support’s “Technical Forum” offers users the opportunity to share information with each other. The “Support Request” option can be used to contact Siemens’ technical support experts. The latest content, software updates, and news via newsletters and Twitter ensure that industry users are always up to date. www.siemens.com/industry/onlinesupport Online Support App Using the Online Support app, you can access over 300,000 documents covering all Siemens industrial products - anywhere, any time. Regardless of whether you need help implementing your project, fault-finding, expanding your system or are planning a new machine. The search function retrieves product information and articles and supports you with a personalized suggestion list. You can find your favorite pages – articles you need frequently – under “mySupport”. You also receive selected news on new functions, important articles or events in the News section. You have access to FAQs, manuals, certificates, characteristics curves, application examples, product notices (e.g. announcements of new products) and information on successor products in the event that a product is discontinued. Just scan the product code printed on the product directly using the camera of your mobile device to immediately see all technical information available on this product at a glance. The graphical CAx information (3D model, circuit diagrams or EPLAN macros) is also displayed. You can forward this information to your workplace using the e-mail function. Scan the QR code for information on our Online Support app. The app is available free of charge from the Apple App Store (iOS) or from Google Play (Android). www.siemens.com/industry/onlinesupportapp Technical Support The ability to quickly analyze system and error messages and take appropriate action are key factors in ensuring that plants run safely and efficiently. Questions can arise at any time and in any industry, whether it’s an individual product or a complete automation solution. Siemens technical support offers individual technical assistance in matters related to functionality, how to operate, applications, and fault clearance in industrial products and systems – at any time and globally, over the phone, by email, or via remote access. Experienced experts from Siemens answer incoming questions promptly. Depending on the requirements, they first consult specialists in the areas of development, on-site services, and sales. Technical support is also available for discontinued products that are no longer available. Using the support request number, any inquiry can be clearly identified and systematically tracked. 13 Siemens ST PCS 7 AO · 2013 13/7 © Siemens AG 2013 Appendix Industry Services Industry Services for the entire life cycle Spare Parts Drive and automation systems must be available at all times. Even a single missing spare part can bring the entire plant to a standstill – and result in substantial financial losses for the operator. The spare parts services from Siemens protects against such losses – with the aid of quickly available, original spare parts that ensure smooth interaction with all other system components. Spare parts are kept on hand for up to ten years; defective parts can be returned. For many products and solutions, individual spare parts packages ensure a preventive stock of spare parts on-site. The spare parts services is available around the world and around the clock. Optimum supply chain logistics ensure that replacement components reach their destination as quickly as possible. Siemens’ logistics experts take care of planning and management as well as procurement, transportation, customs handling, warehousing, and complete order management for spare parts. Repair Services Reliable electrical and electronic equipment is crucial for operating continuous processes. That is why it is essential that motors and converters always undergo highly specialized repair and maintenance. Siemens offers complete customer and repair services – on site and in repair centers – as well as technical emergency services worldwide. The repair services include all measures necessary to quickly restore the functionality of defective units. In addition, services such as spare parts logistics, spare parts storage and rapid manufacturing are available to plant operators in all verticals. With a global network of certified repair shops operated by Siemens as well as third parties, Siemens handles the maintenance and overhaul of motors, converters, and other devices as an authorized service partner. Field Services 13 It’s a top priority in all industries: the availability of plants and equipment. Siemens offers specialized maintenance services such as inspection and upkeep as well as rapid fault clearance in industrial plants – worldwide, continuously, and even with emergency services as needed. The services include startup as well as maintenance and fault clearance during operation. The startup service includes checking the installation, function tests, parameterization, integration tests for machines and plants, trial operation, final acceptance, and employee training. All services, including remote maintenance of drives, are also available as elements of customized service contracts. 13/8 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Appendix Industry Services Industry Services for the entire life cycle Training Increasingly, up-to-date knowledge is becoming a determining factor in success. One of the key resources of any company is well-trained staff that can make the right decision at the right moment and take full advantage of the potential. With SITRAIN – Training for Industry, Siemens offers comprehensive advanced training programs. The technical training courses convey expertise and practical knowledge directly from the manufacturer. SITRAIN covers Siemens’ entire product and system portfolio in the field of automation and drives. Together with the customer, Siemens determines the company’s individual training needs and then develops an advanced training program tailored to the desired requirements. Additional services guarantee that the knowledge of all Siemens partners and their employees is always up-to-date. Technical Consulting & Engineering Support The efficiency of plants and processes leads to sustainable economic success. Individual services from Siemens help save substantial time and money while also guaranteeing maximum safety. Technical consulting covers the selection of products and systems for efficient industrial plants. The services include planning, consulting, and conceptual design as well as product training, application support, and configuration verification – in all phases of a plant’s lifecycle and in all questions related to product safety. Engineering support offers competent assistance throughout the entire project, from developing a precise structure for startup to product-specific preparation for implementation as well as support services in areas such as prototype development, testing and acceptance. Energy & Environmental Services Efficient energy use and resource conservation – these top sustainability concerns pay off – both for the environment and for companies. Siemens offers integrated solutions that unlock all technical and organizational potential for successful environmental management. Customized consulting services are aimed at sustainably lowering the cost of energy and environmental protection and thus increasing plant efficiency and availability. The experts provide support in the conceptual design and implementation of systematic solutions in energy and environmental management, enabling maximum energy efficiency and optimized water consumption throughout the entire company. Improved data transparency makes it possible to identify savings potential, reduce emissions, optimize production processes, and thereby noticeably cut costs. 13 Siemens ST PCS 7 AO · 2013 13/9 © Siemens AG 2013 Appendix Industry Services Industry Services for the entire life cycle Modernization & Optimization Services High machine availability, expanded functionality and selective energy savings – in all industries, these are decisive factors for increasing productivity and lowering costs. Whether a company wants to modernize individual machines, optimize drive systems, or upgrade entire plants, Siemens’ experts support the projects from planning to commissioning. Expert consulting and project management with solution responsibility lead to security and make it possible to specifically identify savings potential in production. This secures investments over the long term and increases economic efficiency in operation. Plant Maintenance & Condition Monitoring Modern industrial plants are complex and highly automated. They must operate efficiently in order to ensure the company’s competitive strength. In addition, the steadily increasing networking of machines and plants require consistent security concepts. Maintenance and status monitoring as well as the implementation of integrated security concepts by Siemens’ experts support optimum plant use and avoid downtime. The services include maintenance management as well as consulting on maintenance concepts, including the complete handling and execution of the necessary measures. Complete solutions also cover remote services, including analysis, remote diagnosis, and remote monitoring. These are based on the Siemens Remote Services platform with certified IT security. Service Contracts 13 Making maintenance costs calculable, reducing interfaces, speeding up response times, and unburdening the company’s resources – the reduced downtimes that these measures achieve increase the productivity of a plant. Service contracts from Siemens make maintenance and repairs more cost-effective and efficient. The service packages include local and remote maintenance for a system or product group in automation and drive technology. Whether you need extended service periods, defined response times, or special maintenance intervals, the services are compiled individually and according to need. They can be adjusted flexibly at any time and used independently of each other. The expertise of Siemens’ specialists and the capabilities of remote maintenance thus ensure reliable and fast maintenance processes throughout a plant’s entire lifecycle. 13/10 Siemens ST PCS 7 AO · 2013 © Siemens AG 2013 Appendix Software Licenses ■ Overview Software types Software requiring a license is categorized into types. The following software types have been defined: • Engineering software • Runtime software Engineering software This includes all software products for creating (engineering) user software, e.g. for configuring, programming, parameterizing, testing, commissioning or servicing. Data generated with engineering software and executable programs can be duplicated for your own use or for use by thirdparties free-of-charge. Runtime software This includes all software products required for plant/machine operation, e.g. operating system, basic system, system expansions, drivers, etc. The duplication of the runtime software and executable programs created with the runtime software for your own use or for use by third-parties is subject to a charge. You can find information about license fees according to use in the ordering data (e.g. in the catalog). Examples of categories of use include per CPU, per installation, per channel, per instance, per axis, per control loop, per variable, etc. Information about extended rights of use for parameterization/configuration tools supplied as integral components of the scope of delivery can be found in the readme file supplied with the relevant product(s). License types Siemens Industry Automation & Drive Technologies offers various types of software license: • Floating license • Single license • Rental license • Rental floating license • Trial license • Demo license • Demo floating license Floating license The software may be installed for internal use on any number of devices by the licensee. Only the concurrent user is licensed. The concurrent user is the person using the program. Use begins when the software is started. A license is required for each concurrent user. Single license Unlike the floating license, a single license permits only one installation of the software per license. The type of use licensed is specified in the ordering data and in the Certificate of License (CoL). Types of use include for example per instance, per axis, per channel, etc. One single license is required for each type of use defined. Rental license A rental license supports the "sporadic use" of engineering software. Once the license key has been installed, the software can be used for a specific period of time (the operating hours do not have to be consecutive). One license is required for each installation of the software. Rental floating license The rental floating license corresponds to the rental license, except that a license is not required for each installation of the software. Rather, one license is required per object (for example, user or device). Trial license A trial license supports "short-term use" of the software in a nonproductive context, e.g. for testing and evaluation purposes. It can be transferred to another license. Demo license The demo license support the "sporadic use" of engineering software in a non-productive context, for example, use for testing and evaluation purposes. It can be transferred to another license. After the installation of the license key, the software can be operated for a specific period of time, whereby usage can be interrupted as often as required. One license is required per installation of the software. Demo floating license The demo floating license corresponds to the demo license, except that a license is not required for each installation of the software. Rather, one license is required per object (for example, user or device). Certificate of license (CoL) The CoL is the licensee's proof that the use of the software has been licensed by Siemens. A CoL is required for every type of use and must be kept in a safe place. Downgrading The licensee is permitted to use the software or an earlier version/release of the software, provided that the licensee owns such a version/release and its use is technically feasible. Delivery versions Software is constantly being updated. The following delivery versions • PowerPack • Upgrade can be used to access updates. Existing bug fixes are supplied with the ServicePack version. PowerPack PowerPacks can be used to upgrade to more powerful software. The licensee receives a new license agreement and CoL (Certificate of License) with the PowerPack. This CoL, together with the CoL for the original product, proves that the new software is licensed. A separate PowerPack must be purchased for each original license of the software to be replaced. Upgrade An upgrade permits the use of a new version of the software on the condition that a license for a previous version of the product is already held. The licensee receives a new license agreement and CoL with the upgrade. This CoL, together with the CoL for the previous product, proves that the new version is licensed. A separate upgrade must be purchased for each original license of the software to be upgraded. Siemens ST PCS 7 AO · 2013 13/11 13 © Siemens AG 2013 Appendix Software Licenses ■ Overview ServicePack ServicePacks are used to debug existing products. ServicePacks may be duplicated for use as prescribed according to the number of existing original licenses. License key Siemens Industry Automation & Drive Technologies supplies software products with and without license keys. The license key serves as an electronic license stamp and is also the "switch" for activating the software (floating license, rental license, etc.). The complete installation of software products requiring license keys includes the program to be licensed (the software) and the license key (which represents the license). 13 13/12 Siemens ST PCS 7 AO · 2013 Software Update Service (SUS) As part of the SUS contract, all software updates for the respective product are made available to you free of charge for a period of one year from the invoice date. The contract will automatically be extended for one year if it is not canceled three months before it expires. The possession of the current version of the respective software is a basic condition for entering into an SUS contract. You can download explanations concerning license conditions from www.siemens.com/automation/salesmaterial-as/catalog/en/ terms_of_trade_en.pdf © Siemens AG 2013 Appendix Index A K S ACRON 7 .........................................................1/7 Adaptive controller...........................................2/6 ADCO...............................................................2/6 AddFEM ...........................................................6/8 AirLINE Ex......................................................6/12 Alarm Control Center .......................................4/3 AS-Interface .....................................................5/5 aspenOne-PCS 7-CONNECT ..........................1/3 Automation Firewall........................................12/2 KSB PumpDrive............................................. 6/15 KVM Extender ................................................. 4/8 KVM Matrixswitches ...................................... 4/10 SICLOCK ....................................................... 12/9 SIMATIC B.Data ............................................. 11/6 SIMATIC HMI Thin Client Ex .......................... 4/15 SIMATIC Logon.............................................. 4/19 SIMATIC PCS 7 PowerControl............... 10/3, 10/4 SIMATIC powerrate........................................ 11/2 SIMATIC RF.................................................... 6/14 SIMATIC SIPAT............................................... 3/21 SIMBApro FAT.................................................. 7/3 SIMIT................................................................ 7/6 SIMOCODE pro ............................................... 6/6 Simulation ........................................................ 7/2 Simulation Based Engineering......................... 7/6 SIPLUS RIC...................................................... 3/9 SIWAREX ......................................................... 6/2 Station Controller ........................................... 10/3 Station Gateway............................................. 10/4 Switchgear/controlgear automation............... 10/2 L Laboratory automation .................................... 9/2 Long-term archiving ........................................ 1/7 Large-screen systems..................................... 4/6 Library 3WL/3VL............................................ 11/9 Library 7KM PAC3200................................. 11/10 B B.Data ............................................................11/6 BANY ...............................................................8/2 Bus analysis.....................................................8/2 C Cabinets.........................................................12/5 Card reader....................................................4/19 CEMAT:.............................................................3/2 Cement industry...............................................3/2 Centrifugal pumps .........................................6/15 Circuit-breakers .............................................11/9 Control rooms...................................................4/6 M Maintenance management ............................. 8/6 Measuring instruments................................ 11/10 MFL ................................................................. 5/4 MINERAL AUTOMATION STANDARD............. 3/6 Mining industry................................................ 3/6 Modbus libraries ............................................. 5/8 Motor management system............................. 6/6 Mouse-Trak.................................................... 4/18 N NeuroSystems ................................................. 2/9 D O Device Manager for SIMATIC Logon .............4/19 Documentation updating system..................... 1/6 Drive ES PCS 7 ................................................6/3 Drives...............................................................6/3 OPD................................................................. 4/2 Operator channel extensions .......................... 4/8 Operator station administration..................... 4/10 Operator's ToolSet......................................... 4/20 E P Electronic signature .........................................4/2 Energy data evaluation ..................................11/2 Energy management .....................................11/2 Ethernet............................................................8/2 PCS 7 LAB Collection...................................... 9/2 PCS 7 OCS...................................................... 1/4 PCS 7 SIMOCODE pro .................................... 6/6 PIMS-PCS 7-CONNECT .................................. 1/2 PLSDOC RE .................................................... 1/6 PM-MAINT ....................................................... 8/6 Pneumatic block............................................ 6/12 Power Control ....................................... 10/3, 10/4 Premium Server ............................................... 4/4 Process Analytical Technology...................... 3/21 PROFIBUS....................................................... 8/2 Protective equipment .................................... 10/2 F Factory Acceptance Test ..........................7/3, 7/6 Fault tracking log .............................................8/4 Fieldbus simulation ..........................................7/3 Fingerprint Mouse..........................................4/19 FuzzyControl++ ...............................................2/7 G Gas analysis library .........................................5/6 I T Technological functionen ................................. 5/4 Telecontrol........................................................ 3/9 Time synchronization ..................................... 12/9 Trackball ........................................................ 4/18 V versiondog ....................................................... 1/8 Video technology ........................................... 4/14 Visor ............................................................... 4/14 W Weighing modules SIWAREX........................... 6/2 R RFID .............................................................. 6/14 ibaPDA/ibaAnalyzer.........................................8/4 IEC 61850 libraries ........................................10/2 INCA MPC........................................................2/2 INCA PID Tuner................................................2/5 INCA Sensor ....................................................2/3 Industry Library................................................5/2 13 Siemens ST PCS 7 AO · 2013 13/13 © Siemens AG 2013 Appendix Order No. Index 2XV9 6DL3 6SW1 2XV9 450-1AR14 .........................................12/10 2XV9 450-1AR21 .........................................12/10 2XV9 450-1AR28 .........................................12/11 2XV9 450-1AR30 .........................................12/10 2XV9 450-1AR32 .........................................12/10 2XV9 450-1AR35 .........................................12/10 2XV9 450-1AR36 .........................................12/10 2XV9 450-1AR63-1SA3 ...............................12/11 2XV9 450-1AR64 .........................................12/11 2XV9 450-1AR72 .........................................12/11 2XV9 450-1AR73 .........................................12/11 2XV9 450-1AR82 .........................................12/11 2XV9 450-1AR83 .........................................12/11 2XV9 450-1WC10-.... ......................................2/8 2XV9 450-1WC11-.... ......................................2/8 2XV9 450-1WC15-.... ....................................2/10 2XV9 450-1WC16-.... ....................................2/10 2XV9 450-2AR01 .........................................12/10 2XV9 450-2AR10 .........................................12/10 2XV9 450-2AR20 .........................................12/10 2XV9 450-2AR22 .........................................12/10 2XV9 450-2AR26 .........................................12/10 2XV9 450-2AR50 .........................................12/10 2XV9 450-2AR81 .........................................12/11 6DL3 100-8AC .............................................. 6/11 6DL3 100-8AC03 .......................................... 6/11 6SW1 700-0JA00-0AB2 6SW1 700-0JA00-1AB2 6SW1 700-0JD00-0AB2 6SW1 700-5JA00-5AA0 6SW1 700-5JA00-5AA1 6SW1 700-5JA00-5AA4 6SW1 700-5JD00-1AC0 6SW1 700-7JD00-0AA0 6SW1 700-7JD00-1AA0 6SW1 700-7JD00-1AA4 6SW1 700-8JD00-0AA0 6SW1 700-8JD00-0AA4 6SW1 700-8JD01-0AA0 3UF7 3UF7 982-.... ...................................................6/7 3ZS1 3ZS1 635-.... ...................................................5/6 3ZS2 781-.... ...............................................11/10 3ZS2 782-.... .................................................11/9 6AG6 13 6AG6 003-0AC02-0AA0 ................................ 3/17 6AG6 003-0AC12-0AA0 ................................ 3/17 6AG6 003-0AC42-0AA0 ................................ 3/17 6AG6 003-0BA01-0AA0 ....................... 3/16, 3/20 6AG6 003-0BA11-0AA0 ....................... 3/16, 3/20 6AG6 003-0BB11-0AA0 ....................... 3/16, 3/20 6AG6 003-1AE03-0CA0 ................................ 3/17 6AG6 003-1AE05-0DA0 ................................ 3/17 6AG6 003-1AE06-0DA0 ................................ 3/17 6AG6 003-1BA01-1BA0 ................................ 3/14 6AG6 003-1BA01-4BA0 ................................ 3/14 6AG6 003-1BA02-4CA0 ................................ 3/14 6AG6 003-1BA03-4CA0 ................................ 3/14 6AG6 003-1BA05-4DA0 ................................ 3/15 6AG6 003-1BA06-4DA0 ................................ 3/15 6AG6 003-1BA07-4CA0 ................................ 3/14 6AG6 003-1BA10-4CA0 ................................ 3/14 6AG6 003-1BB.. ............................................3/15 6AG6 003-2A... .............................................3/17 6AG6 003-2B... ..............................................3/15 6AG6 003-3B... .............................................3/16 6AG6 003-4B... .............................................3/16 6AG6 003-5A... .............................................3/17 6AG6 003-5B... ..............................................3/14 6AG6 003-6A... .............................................3/17 6AG6 003-6B... .............................................3/14 6AV6 6AV6 372-1DE.. .............................................11/5 6AV6 372-1DF... ............................................11/8 6AV7 6DL5 6DL5 405-8AD33-0XA0 .................................. 1/5 6DL5 408-8AX01-0XL1 ................................... 9/7 6DL5 410-8AA08-0XL1 .................................. 5/3 6DL5 410-8AA08-0YA0 .................................. 5/3 6DL5 410-8AB08-0XL1 .................................. 5/3 6DL5 410-8AX08-0YA0 ................................... 5/3 6DL5 422-1AX04-0BA5 ................................ 3/28 6DL5 422-1BA00-0BL8 ................................. 3/30 6DL5 422-1BA04-0BB5 ................................ 3/28 6DL5 422-1BX04-0BB5 ................................ 3/28 6DL5 422-1CA04-0BB5 ................................ 3/28 6DL5 422-1DA04-0BB5 ................................ 3/28 6DL5 422-1DA04-1BB5 ................................ 3/29 6DL5 422-1DA04-2BB5 ................................ 3/29 6DL5 422-1EA04-0BB5 ................................ 3/29 6DL5 422-1FA04-0BB5 ................................ 3/29 6DL5 422-4AX04-0BA5 ................................ 3/28 6DL5 422-4BA04-0BB5 ................................ 3/28 6DL5 422-4CA04-0BB5 ................................ 3/28 6DL5 422-4DA04-0BB5 ................................ 3/28 6DL5 422-4DA04-1BB5 ................................ 3/29 6DL5 422-4DA04-2BB5 ................................ 3/29 6DL5 422-4FA04-0BB5 ................................ 3/29 6DL5 422-8EA04-0BA5 ................................ 3/30 6DL5 422-8XA04-0BA5 ................................ 3/28 6DL5 422-8XB04-0BA5 ................................ 3/28 6DL5 422-8XC04-0BA5 ................................ 3/29 6DL5 422-8XD04-0BT7 ................................ 3/29 6DL5 430-8AX08-0XE0 .................................. 3/4 6DL5 430-8AX17-0XE0 .................................. 3/5 6DL5 433-8AA08-0XA0 ........................... 3/4, 3/8 6DL5 433-8AA17-0XA0 .................................. 3/5 6DL5 433-8AB08-0XA0 ........................... 3/4, 3/8 6DL5 433-8AB08-0XD0 ........................... 3/4, 3/8 6DL5 433-8AB17-0XA0 .................................. 3/5 6DL5 433-8AB17-0XD0 .................................. 3/5 6DL5 433-8AC08-0XA0 ........................... 3/4, 3/8 6DL5 433-8AC08-0XD0 ........................... 3/4, 3/8 6DL5 433-8AC17-0XA0 .................................. 3/5 6DL5 433-8AC17-0XD0 .................................. 3/5 6DL5 433-8AD08-0XA0 ........................... 3/4, 3/8 6DL5 433-8AD08-0XD0 ........................... 3/4, 3/8 6DL5 433-8AD17-0XA0 .................................. 3/5 6DL5 433-8AD17-0XD0 .................................. 3/5 6DL5 434-8AA08-0XA0 ........................... 3/4, 3/7 6DL5 434-8AA17-0XA0 .................................. 3/5 6DL5 435-8AX08-0XA0 ........................... 3/4, 3/7 6DL5 435-8AX17-0XA0 .................................. 3/5 6DL5 436-8AX08-0XA0 ........................... 3/4, 3/7 6DL5 436-8AX17-0XA0 .................................. 3/5 6DL9 6DL9 200-8AA 6DL9 201-8AA 6DL9 900-8AA 6DL9 900-8AB 6DL9 901-8AA 6DL9 902-8AA 6DL9 902-8AB 6DL9 903-8AA 6DL9 903-8AB .............................................. 6/11 .............................................. 6/11 .............................................. 6/11 .............................................. 6/11 .............................................. 6/11 .............................................. 6/11 .............................................. 6/11 .............................................. 6/11 .............................................. 6/11 6AV7 200- ..................................................... 4/16 6AV7 675-0.... ...............................................4/16 6GK1 6DL2 6GT2 6DL2 800- ..................................................... 12/6 6DL2 802-..... ................................................12/7 6DL2 803-1.... ...............................................12/8 6GT2 002-0ED00 .......................................... 6/14 6GT2 002-0GA10 ......................................... 6/14 6GT2 080-2AA20 .......................................... 6/14 13/14 Siemens ST PCS 7 AO · 2013 6GK1 551-2AA00 ........................................... 8/3 .................................. 6/5 .................................. 6/5 .................................. 6/5 .................................. 6/4 .................................. 6/4 .................................. 6/5 .................................. 6/4 .................................. 6/4 .................................. 6/4 .................................. 6/5 .................................. 6/4 .................................. 6/5 .................................. 6/4 7MH4 7MH4 900-2.... ................................................ 6/2 7MH4 900-3.... ................................................ 6/2 7MH4 950-3.... ................................................ 6/2 9AE4 9AE4 100-1D... ............................................... 8/3 9AE4 100-1E... .............................................. 10/5 9AE4 100-1G... ............................................. 10/3 9AE4 100-4L... .............................................. 4/19 9AE4 110-1MB10 ............................................ 5/9 9AE4 110-1MB20 ............................................ 5/9 9AE4 110-2AB00 .......................................... 10/2 9AE4 110-2MB10 ............................................ 5/9 9AE4 110-2MB20 ............................................ 5/9 9AE4 110-3AB00 ............................................ 5/7 9AE4 122-1AA00 ............................................ 7/5 9AE4 122-1AB00 ............................................ 7/5 9AE4 122-1AC00 ............................................ 7/5 9AE4 130-1AA00 ............................................ 7/5 9AE4 310-..... .................................................. 4/3 9AE4 510-..... .................................................. 4/5 9AE7 9AE7 104-2SS30-1AA0 ................................... 8/7 9AE7 104-4SC00-1AA0 .................................. 8/7 9AP1 9AP1 420-1BB10 9AP1 422-1BB10 9AP1 433-1CB10 9AP1 434-1CB10 9AP1 438-1CB10 9AP1 440-1CB10 9AP1 441-1CB10 9AP1 442-1CB10 9AP1 443-1CB10 9AP1 444-1CB10 9AP1 445-1CB10 9AP1 450-1CB10 9AP1 460-1CB10 9AP1 461-1CB10 9AP1 471-2AD00 ............................................ 7/7 ............................................ 7/7 ............................................ 7/7 ............................................ 7/8 ............................................ 7/8 ............................................ 7/8 ............................................ 7/8 ............................................ 7/8 ............................................ 7/8 ............................................ 7/8 ............................................ 7/8 ............................................ 7/9 ............................................ 7/7 ............................................ 7/7 ............................................ 7/9 9AP2 9AP2 430-..... .................................................. 7/9 9AP2 431-.... ................................................... 7/9 9AP2 440-..... .................................................. 7/9 9AS1 9AS1 4.. ........................................................ 12/4 © Siemens AG 2013 Appendix Notes 13 Siemens ST PCS 7 AO · 2013 13/15 © Siemens AG 2013 Appendix Conditions of sale and delivery ■ 1. General Provisions By using this catalog you can acquire hardware and software products described therein from Siemens AG subject to the following Terms and Conditions of Sale and Delivery (hereinafter referred to as "T&C"). Please note that the scope, the quality and the conditions for supplies and services, including software products, by any Siemens entity having a registered office outside Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. The following T&C apply exclusively for orders placed with Siemens Aktiengesellschaft, Germany. 1.1 For customers with a seat or registered office in Germany For customers with a seat or registered office in Germany, the following applies subordinate to the T&C: • the "General Terms of Payment"1) and, • for software products, the "General License Conditions for Software Products for Automation and Drives for Customers with a Seat or Registered Office in Germany"1) and, • for other supplies and services, the "General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry"1). 1.2 For customers with a seat or registered office outside Germany For customers with a seat or registered office outside Germany, the following applies subordinate to the T&C: • the "General Terms of Payment"1) and, • for software products, the "General License Conditions for Software Products for Automation and Drives for Customers with a Seat or Registered Office outside of Germany"1) and • for other supplies and/or services, the "General Conditions for Supplies of Siemens Industry for Customers with a Seat or Registered Office outside of Germany"1). ■ 2. Prices 13 The prices are in € (Euro) ex point of delivery, exclusive of packaging. The sales tax (value added tax) is not included in the prices. It shall be charged separately at the respective rate according to the applicable statutory legal regulations. Prices are subject to change without prior notice. We will charget the prices valid at the time of delivery. To compensate for variations in the price of raw materials (e.g. silver, copper, aluminum, lead, gold, dysprosium and neodym), surcharges are calculated on a daily basis using the so-called metal factor for products containing these raw materials. A surcharge for the respective raw material is calculated as a supplement to the price of a product if the basic official price of the raw material in question is exceeded. The metal factor of a product indicates the basic official price (for those raw materials concerned) as of which the surcharges on the price of the product are applied, and with what method of calculation. An exact explanation of the metal factor can be downloaded at: www.siemens.com/automation/salesmaterial-as/catalog/en/ terms_of_trade_en.pdf To calculate the surcharge (except in the cases of dysprosium and neodym), the official price from the day prior to that on which the order was received or the release order was effected is used. To calculate the surcharge applicable to dysprosium and neodym ("rare earths"), the corresponding three-month basic average price in the quarter prior to that in which the order was received or the release order was effected is used with a onemonth buffer (details on the calculation can be found in the explanation of the metal factor). 13/16 Siemens ST PCS 7 AO · 2013 ■ 3. Additional Terms and Conditions The dimensions are in mm. In Germany, according to the German law on units in measuring technology, data in inches apply only to devices for export. Illustrations are not binding. Insofar as there are no remarks on the individual pages of this catalog - especially with regard to data, dimensions and weights given - these are subject to change without prior notice. ■ 4. Export regulations We shall not be obligated to fulfill any agreement if such fulfillment is prevented by any impediments arising out of national or international foreign trade or customs requirements or any embargoes and/or other sanctions. Export of goods listed in this catalog may be subject to licensing requirements. We will indicate in the delivery details whether licenses are required under German, European and US export lists. Goods labeled with "AL" not equal to "N" are subject to European or German export authorization when being exported out of the EU. Goods labeled with "ECCN" not equal to "N" are subject to US re-export authorization. The export indications can be viewed in advance in the description of the respective goods on the Industry Mall, our online catalog system. Only the export labels "AL" and "ECCN" indicated on order confirmations, delivery notes and invoices are authoritative. Even without a label, or with label "AL:N" or "ECCN:N", authorization may be required i .a. due to the final disposition and intended use of goods. If you transfer goods (hardware and/or software and/or technology as well as corresponding documentation, regardless of the mode of provision) delivered by us or works and services (including all kinds of technical support) performed by us to a third party worldwide, you must comply with all applicable national and international (re-)export control regulations. If required for the purpose of conducting export control checks, you (upon request by us) shall promptly provide us with all information pertaining to the particular end customer, final disposition and intended use of goods delivered by us respectively works and services provided by us, as well as to any export control restrictions existing in this relation. The products listed in this catalog may be subject to European/German and/or US export regulations. Any export requiring approval is therefore subject to authorization by the relevant authorities. Errors excepted and subject to change without prior notice. 1) The text of the Terms and Conditions of Siemens AG can be downloaded at www.siemens.com/automation/salesmaterial-as/catalog/en/ terms_of_trade_en.pdf © Siemens AG 2013 Catalogs Industry Automation, Drive Technologies and Low-Voltage Power Distribution Further information can be obtained from our branch offices listed at www.siemens.com/automation/partner System Solutions Interactive Catalog on DVD Catalog Products for Automation and Drives CA 01 Drive Systems Variable-Speed Drives SINAMICS G130 Drive Converter Chassis Units SINAMICS G150 Drive Converter Cabinet Units SINAMICS GM150, SINAMICS SM150 Medium-Voltage Converters ROBICON Perfect Harmony Medium-Voltage Air-Cooled Drives Germany Edition SINAMICS S120 Chassis Format Units and Cabinet Modules SINAMICS S150 Converter Cabinet Units SINAMICS DCM Converter Units SINAMICS and Motors for Single-Axis Drives D 11 D 12 D 15.1 D 21.3 D 23.1 D 31 Three-Phase Induction Motors SIMOTICS HV • Series H-compact • Series H-compact PLUS D 84.1 Asynchronous Motors Standardline Synchronous Motors with Permanent-Magnet Technology, HT-direct DC Motors SIMOREG DC MASTER 6RA70 Digital Chassis Converters SIMOREG K 6RA22 Analog Chassis Converters Digital: SIMOREG DC MASTER 6RM70 Digital Converter Cabinet Units SIMOVERT PM Modular Converter Systems SIEMOSYN Motors MICROMASTER 420/430/440 Inverters MICROMASTER 411/COMBIMASTER 411 SIMOVERT MASTERDRIVES Vector Control SIMOVERT MASTERDRIVES Motion Control Synchronous and asynchronous servomotors for SIMOVERT MASTERDRIVES SIMODRIVE 611 universal and POSMO Note: Additional catalogs on SIMODRIVE or SINAMICS drive systems and SIMOTICS motors with SINUMERIK and SIMOTION can be found under Motion Control D 86.1 D 86.2 DA 12 DA 21.1 DA 21.2 DA 22 DA 45 DA 48 DA 51.2 DA 51.3 DA 65.10 DA 65.11 DA 65.3 DA 65.4 Low-Voltage Three-Phase-Motors SIMOTICS Low-Voltage Motors MOTOX Geared Motors SIMOGEAR Geared Motors D 81.1 D 87.1 MD 50.1 Mechanical Driving Machines FLENDER Standard Couplings FLENDER SIG Standard industrial gear unit FLENDER SIP Standard industrial planetary gear units MD 10.1 MD 30.1 MD 31.1 Low-Voltage Power Distribution and Electrical Installation Technology SENTRON Protection, Switching, Measuring and Monitoring Devices SIVACON · ALPHA Switchboards and Distribution Systems Standards-Compliant Components for Photovoltaic Plants 3WT Air Circuit Breakers up to 4000 A 3VT Molded Case Circuit Breakers up to 1600 A Digital: SIVACON System Cubicles, System Lighting and System Air-Conditioning Digital: ALPHA Distribution Systems ALPHA FIX Terminal Blocks SIVACON S4 Power Distribution Boards SIVACON 8PS Busbar Trunking Systems Digital: These catalogs are only available as a PDF and/or as an e-book. LV 10.1 Building Control GAMMA Building Control Motion Control SINUMERIK & SIMODRIVE Automation Systems for Machine Tools SINUMERIK & SINAMICS Equipment for Machine Tools SINUMERIK 840D sl Type 1B Equipment for Machine Tools SINUMERIK 808D, SINAMICS V60 and G120, SIMOTICS 1FL5 and 1LE1 SINUMERIK 828D BASIC T/BASIC M, SINAMICS S120 Combi, 1FK7 and 1PH8 motors SIMOTION, SINAMICS S120 and Motors for Production Machines Drive and Control Components for Cranes Power Supply and System Cabling Power supply SITOP System cabling SIMATIC TOP connect Process Instrumentation and Analytics Field Instruments for Process Automation Digital: SIPART Controllers and Software Products for Weighing Technology Digital: Process Analytical Instruments Digital: Process Analytics, Components for the System Integration Catalog ET G1 NC 60 NC 61 NC 62 NC 81.1 NC 82 PM 21 CR 1 KT 10.1 KT 10.2 FI 01 MP 31 WT 10 PA 01 PA 11 Safety Integrated Safety Technology for Factory Automation SI 10 SIMATIC HMI/PC-based Automation Human Machine Interface Systems/ PC-based Automation ST 80/ ST PC SIMATIC Ident Industrial Identification Systems ID 10 SIMATIC Industrial Automation Systems Products for Totally Integrated Automation and Micro Automation SIMATIC PCS 7 Process Control System Add-ons for the SIMATIC PCS 7 Process Control System Digital: Migration solutions with the SIMATIC PCS 7 Process Control System SIMATIC NET Industrial Communication ST 70 ST PCS 7 ST PCS 7 AO ST PCS 7.2 IK PI LV 10.2 LV 11 SINVERT Photovoltaics Inverters and Components for Photovoltaic Installations RE 10 LV 35 LV 36 LV 50 SIRIUS Industrial Controls SIRIUS Industrial Controls LV 51 LV 52 LV 56 LV 70 Information and Download Center IC 10 PDF versions of the catalogs are available on the Internet at: www.siemens.com/automation/infocenter Please note the section “Downloading catalogs” on page “Online services” in the appendix of this catalog. © Siemens AG 2013 Get more information Comprehensive information concerning the SIMATIC PCS 7 process control system: www.siemens.com/simatic-pcs7 Siemens AG Industry Sector Industrial Automation Systems Postfach 48 48 90026 NÜRNBERG GERMANY www.siemens.com/automation Subject to change without prior notice Order No. E86060-K4678-A121-B1-7600 MQ.R4.AS.SID2.02.3.76 / Dispo 09508 KG 0313 2. AUM 176 En Printed in Germany © Siemens AG 2013 The information provided in this catalog contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.