Klixon and 285 Series Mounting Options Klixon Circuit Breakers

Transcription

Klixon and 285 Series Mounting Options Klixon Circuit Breakers
CIRCUIT PROTECTION AND SWITCHES 67
bluesea.com
Fuse Block Specification Table
MAXI®
ST-Glass
56 / 5006100
56 / 5015, 5018
57 / 5023
58 / 5035, 5037
59 / 5032
60 / 5045, 5046
61 / 5028, 5025,
5029, 5026
For use with
MAXI®
AGC® or MDL®
ATO® or ATC®
ATO® or ATC®
ATO® or ATC®
ATO® or ATC®
ATO® or ATC®
Maximum Voltage
Product
Page number / PN
ST-Blade
32V DC
32V DC
32V DC
32V DC
32V DC
32V DC
32V DC
Maximum Amperage
per circuit
80A
30A
30A
30A
30A
30A
30A
Maximum Amperage
per block
80A
100A
100A
40A per jumped
circuit group
100A (not to exceed
80A per load group)
100A
100A
30–80A
.25–30A
1–30A
1–30A
1–30A
1–30A
30–300A
Available Fuses
Ingress Protected
IP66-protected
against powerful
water jets.
––
IP66-protected
against powerful
water jets.
––
––
IP66-protected
against powerful
water jets.
––
Ignition Protected
ISO 8846,
SAE J1171 when
cover is secure.
––
ISO 8846,
SAE J1171 when
cover is secure.
––
––
ISO 8846,
SAE J1171 when
cover is secure.
––
MEGA® or AMG®
Class T
Class T
Class T
63 / 5502100
Product
MRBF Terminal
MRBF Surface
MRBF Surface
Page number / PN
62 / 2151, 5191
62 / 5194
62 / 5196
62 / 5001
63 / 5502
63 / 5007100
For use with
Terminal (MRBF)
Terminal (MRBF)
Terminal (MRBF)
MEGA® or AMG®
Class T
Class T
Class T
32V DC
160V DC
160V DC
160V DC
Maximum Voltage
58V DC
58V DC
Maximum Amperage
per circuit
300A
240A
240A
300A
320A
160A
320A
Maximum Amperage
per block
300A
––
300A
300A
320A
160A
320A
30–300A
30–300A
30–300A
100–300A
225–400A
110–200A
225–400A
––
––
––
––
––
––
Available Fuses
Ingress Protected
IP66 when used
with Blue Sea
Systems' Terminal
(MRBF) Fuses.
Ignition Protected
SAE J1171 when used
with Blue Sea Systems' MRBF fuses.
Product
Page number / PN
For use with
Maximum Voltage
––
ANL®
ANL®
63 / 5005
63 / 5503
ANL®
ANL®
Safety AMI® or MIDI®
ISO 8846,
SAE J1171 when
cover is secure.
ISO 8846,
SAE J1171 when
cover is secure.
Safety MEGA® or AMG®
SafetyHub 100
SafetyHub 150
64 / 7720
64 / 7721
65 / 7725
65 / 7748
AMI® or MIDI®
MEGA® or AMG®
AMI® or MIDI® and ATO® or ATC®
32V DC
32V DC
32V DC
32V DC
12V DC
32V DC
Maximum Amperage
per circuit
300A
750A
200A
300A
AMI® or MIDI®: 250A
ATO® or ATC®: 30A
AMI® or MIDI®: 170A
ATO® or ATC®: 25A
Maximum Amperage
per block
300A
750A
200A
300A
ATO® or ATC®: 50A
AMI® or MIDI®: 280A
ATO® or ATC®: 50A
Maximum Total
Amperage (combined)
35–300A
––
––
––
280A
AMI®
or MIDI®: 30–200A
ATO® or ATC®: 1–30A
AMI®
or MIDI®: 30–200A
ATO® or ATC®: 1–30A
Available Fuses
––
35–750A
Ingress Protected
––
––
IP66-protected against powerful water jets.
IP66-protected against powerful water jets.
Ignition Protected
––
––
ISO 8846, SAE J1171 when cover is secure.
ISO 8846, SAE J1171 when cover is secure.
30–200A
100–300A