Manual Total Stations with OptiGal Theodolites and Integral
Transcription
Manual Total Stations with OptiGal Theodolites and Integral
Manual Total Stations with OptiGal Theodolites and Integral EleGtroniG DistanGe Meters ~ Upright display, even w hen the telescope is inverted, for easy reading at all times. Clear, display. high-contrast liquid crystal 3600 fully transiting telescope paired fore and back sightings. allows Coaxial optics. Both distance and angle measurements can be carried at one setting because the EDM's axis is on the same line of sight as the theodolite's telescope. Wide range. Measurements of up to 2,300m (7,600ft) [triple prism] and 1,600m (5,300ft) [single prism] in ideal atmospheric conditions, and 1,800m (5,900ft) [triple prism] and 1,200m (4,OOOft) [single prism] in normal conditions are possible. Data output terminal transfers obtained data to an optional recorder. Direct digital angle reading. Each minimum scale is numbered and appears in a large micrometer viewfield for easy-toread angle measurements. Wireless remote control. The convenient FK-1 Keyboard permits simple, mistakefree operatjon from up to 2 meters (7 feet) away. Automatic environmental compensation. Simply key-in the pressure and temperature values; there's no need for a conversion chart. , _~ne e','~ ~~:~.. ~ ~~.- {i"9 'Jef\\Ca\ \af'gef'\ ~ ~ ~ -u~~e{ ~\a\e \a{\ge{\\ Yi!!~ ~ --- 3 Upright Digital Display Even if the telescope is inverted, the liquid crystal readout always displays digits upright for quick, errorfree reading. Automatic Self-diagnosis A self-check is automatically performed each time the power is turned on. If the instrument is operating correctly, the panel displays "Good," jf a problem exists, an error code is displayed. =-c~ Audible and Digital Target Acquisition W hen light ref!ected by a prism is received, a buzzer sounds and the numerica! va!ue (between O and 15) of the returned signal's strength is disp!ayed on the L CD board. As a result, fine adjustment during target sighting is extremely easy. At short distances, mere!y point the telescope at the target prism's center. W hen reflected light is weak, the panel displays "LO" to indicate that measurement is not possib!e. .--~ .=- , -f fC --.::::=;:::, Automatic Environmental Compensation This function eliminates the need for a conversion chart. Betore measuring, simply key-in the values for the barometric pressure (mmHg or inches Hg) and temperature (OC or OF). The instrument then automatically compensates for these environmental factors betore displaying the distance. Temperature range: -25°C -55°C (-13°F-131°F) Pressure range: 400mmHg-999mmHg (15.7inHg-39.3inHg) Automatic Gurvature and Refraction Gompensation W hen the appropriate internal switch is set, the instrument automatically compensates for the earth's curvature and differences in air densit y. Permanent Prism Constant Storage Even w hen the main switch is turned 1 off, the preset prism constant is per- L manently memorized until a new prism constant is entered through ~ the keyboard. Prism offset correction :i: 999 mm 4 range: Buzzer Automatic Signal Level Control The arnount of reflected light is autornatically attenuated after target acquisition, allowing rneasurernent to begin irnrnediately. Distance Measurement Operation Display At the start of distanGe measurement, the display's liquid Grystal lights and travels from right to lett to indiGate that the distanGe measurement tunGtion is operating. ~ Q Q v Automatic Erroneous. Data Detection W hen the spread of the fine readings exceeds a predetermined operating range because of hale, stray light, or any other reason, the microprocessor automatically detects and deletes the erroneous data to ensure accuracy. Automatic InterruptedMeasurement Resumption It the infrared signal is interrupted by traffic, foliage, or other obstacles during measurements, the instrument immediately stops operating. W hen the path is clear, measurement resumes automatically with no decrease in accuracy. Incorrect.Data Recognition If an irregular value (such as an angle of 30061 '20") is mistaken ly keyed-in, the incorrect value is automatically cancelled and the input is cleared. Two-step Low Voltage Warning If the rechargeable battery's voltage is low, the display's decimal point blinks to warn that normal operation is possible for only about a few minutes. W hen the voltage drops below a specific level, the panel displays "HELP" to indicate that further measurement is not possible. Automatic Power Shutoff If no measurement is made and no key operatjon is performed within approximately four minutes of the power being turned on, the instrument automatically shuts off to extend battery life. Multiple Measurement Modes This instrument provides three measurement modes: single, repeat, and averaged. Selection is made with the "AVE" key. Single measurement: Only a single measurement is made. Repeat measurement: Measurements are made until a new command is given. Averaged measurement: After a preset number of measurements have been made, a buller sounds and the averaged value of the measurements is displayed. The instrument can make up to 99 measurements. ~ Automatic Slope Reduction W hen the zenith angle has been entered, the keyboard can be used to calculate and display the slope distance, horizontal distance, and difference in elevation. Moving Prism Tracking Function For construction staking and other jobs where time is limited, the instrument allows the measurement of a moving prism. In the tracking mode, the distance meter can accurately measure a prism that is moving toward or away from the instrument at up to 2m (7ft) per second. Automatic measurement takes ,place every second, and display resolution can be either 10 mm or 0.1 ft. Stake.out Function After a preset distance has been entered, the difference between the preset distance and the measured distance is automatically displayed. This function is particularly convenient w hen used in conjunction with the tracking function. Preset distances of up to 9999.999m (9999.99ft) can be entered. Coordinate Computation After distance measurement, the panel displays the target point's coordinates (relative to the coordinates of the instrument station). The X. Y. l. coordinates are calculated from the previously entered horizontal and zenith angles. Either local rectangular coordinates or grid coordinates can be used (easting, northing). Coordinates settings can range from -9999.999 m to + 9999.999 m or from -9999.99 ft. to + 9999.99 ft. Caaxial Telescape Since the EDM's transmitter and receiver and the theodolite's telescope are on the same optical axis, angle and distance measurements are performed simultaneously with a single sighting. 30X, 45 mm.diameter Telescape A large 45 mm-diameter aperture, 30X-magnificatian telescape with an extra-wide field af view pravides a clear, erect, unreversed image with ample brightness. Optianal 20X and 40X interchangeable eyepieces are alsa available. Fully Transiting Telescape The compact coaxial telescope with its built-in battery transits 3600 to eliminate horizontal collimation errors by allowing both target faces to be observed and measured. LED Reticle lIIumination To maintain the instrument's operating ease at night and in dark areas, an LED is built in to illuminate the telescope's reticle. Finder(Optical Sight) Far quick sighting, a callimatar target finder is pravided an the tap af the telescape hausing. Built.in Automatic Zenith Index The built-in automatic compensator, with a magnet-type damper, allows quick instrument set-up and ensures accurate measurement of vertical angles at all times. ~ Easy.to-read Digital Display NTD-series instruments are available with 5 different minimum numerical readings-6", 10", 20", 2mgon, and 5mgon. Large, easy-to-read micrometer and subdivision index dots (not included in the 5mgon instrument) provide further reading to 3", 5", 10", and 1 mgon, respectively. Diametrically Opposed Side Circle Reading The horizontal circle is diametrically opposed to eliminate eccentricity and increase accuracy. A ~ ~ Optical Plummet An optical plummet built into the instrument's alidade ensures erect, unreversed images and permits quick, precise orientation over any given point. It focuses from O.5m (1.5ft) to infinity and has a 3X magnification. Coaxial Tangent Screws and Clamps The fine-travel coaxial tangent screws and clamps are easy to operate. The horizontal and vertical tangent screw knobs are metal covered by knurled rubber to facilitate operation with or without gloves in all types of weather. Detachable Leveling Base The tribrach leveling base can be quickly detached from the instrument to enable the target to be fixed for traversing. The tripod screw has a S/8-inch diameter and 11 threads perinch. \1;' 5 Wireless Function Keyboard Except for angular measurernents, all operations can be conducted with the handy remmote keyboard. Transmission is possible within a 2m-Iong (7ft-Iong) cone-shaped area extending out at a 30° angle (vertically and horizontally) from the receiver window on the main body. Main Body Operation Operatjon I Key Functions "One" Entry Zenith Angle "Two" Entry Temperature and Entry and and Pressure Keys This switch turns the telescope's reticle illuminator on. The illuminator automatically turns off after approximately 1 minute. Entry Display "Three" Entry Prism Constant Entry and Display "Faur" Entry Distance Measurement Setting Displayand Display Made "Five" Entry Return Signal Strength Verification "Six" Entry Horizontal Angle Entry and Display The display shows the numerical value of light reflected by a prism. A bUller sounds w hen the value of the reflected light increases. "Seven" Entry Unknown (Target) Point's X. Y. and l. Coordinates Display (relative to the coordinates of the instrument station) This button starts continuous measurements of a prism moving at up to approximately 2m/sec (7ft/sec). The first measured distance is displayed after about 15 seconds; the second after 5 seconds. Later measured distances are displayed at 1-second intervals. "Eight" Entry Local Rectangular Coordinates Grid Coordinates of the Instrument Station Entry "Nine" Entry Distance Preset (stake-out) Display This button starts the distance measurements and displays the first measured distance after about 15 seconds. Thereafter, measured distances are displayed at 5-second intervals. The LCD lights during measurement. Internal These turn switches functions on and Switch 1 : Selects sex agesirnal (3600) or centesirnal (400gon) angle units. This switch is set at the factory to conform with the theodolite's vertical and horizontal circles. Switch 2: Selects distance and ternperature units (Meters + Centigrade or Feet + Fahrenheit). Switch 3: Selects local rectangular coordinates or grid coordinates. (easting, northing) 6 select units and "Zero" Entry Slope Reduction S: Slope distance H: Horizontal distance V: Vertical height difference "Minus" Entry Tracking Mode Switches slide or or off. DistanGe Measurement Value Entry Switch 4: Selects zenith angle or vertical angle. This switch is set at the factory to conform with the theodolite's vertical circle. Switch 5: Switches earth curvature correction and refraction correction functions on and off. Standard Set Start t Target plate for single prism holder Prism pole = Power or ~ cord for 100/120V for 220/240V Car Battery Cord Type W ~-~ Car Battery Cord Type S ~~ Single prism I Single Triple prism holder prism holder Fi ti:J I Leveling Base Adapter I (with optical plummeU Mini prism Leveling Base W-10 Type 3 Distance Measurement Range with Nikon prisms With a single prism With a triple prism (Under average1 atmospheric conditions) 1.200m (4.000ft) 1.800m (5.900ft) (Under ideal2 atmospheric conditions) With a single prism 1 ,600m (5,300ft) With a triple prism 2,300m (7.600ft) [ 1: Slight haze with visibility about 15km (50,OOOft), moderate sunlight with light heat shimmer ] [2: Overcast. no haze. visibility over 30km (100.000ft). no heat shimmer ] :i:(5mm+5ppm.D) Accuracy Display meansquare error 7 digit liquid crystal display Max. range display: 3.999.999 m (~,999.99fU MSR Normal distance measurement 1 mm (0.01 ft) TRK (Tracking): 1 cm (0.1 ft) Least count Meter/feet selectable Measuring time MSR: 5 sec. (from 2 nd shot TRK: 1 sec. (from 3rd shot) -20°C- Direct input of temperature and pressure Temperature range: -25°C+55°C (1°C steps)or -13°F-+131°F (1°F steps) Pressure range: 400mmHg-999mmHg (1 mmHg steps) or 15.7inHg-39.3inHg (0.1 in Hg steps) +50°C(-4°F- Unit Meter + Centigrade/Feet selectable Prism offset correction -999mm- Angle Measurement 360° Horizontal circle Circle diameter Minimum increment Micrometerincrement 6" 3" vertical 360° 2mgon 1mgon 10" 5" 19on 6" 2mgon 3" 1 mg on 10. 5. 20" 10" 1° 19on 20w Smgon 10w Magnetic damper %5' %0.5H Coaxial, internal focus, anallactic system 177mm(6.97in) optical of 45mm(1.77in) The equipment shown in this brochure represents the latest available at the time of printing. Designs and specifications are subject to change without notice. May 1984 NIPPON KOGAKU Plastic carrying carrying case 177mm(L)x 167mm(W)x374mm(H) (7.0Nx6.6NX14.7N) 6.6 kg ( 14.5 Ib) 488mm(L) x 280mm(W) x 256mm(H) (19.2NX11.0Nx10.1N) 5.0kg(11.0Ib) Power Supply Type BY-2, rechargeable Ni-Cd, sljde-in, cordless connectjon 8.4V 500mAh 3A lead fuse 50 mjnutes continuous (wjth full recharge) -20°C+50°C ( -4°F -+122°F) +10°C+40°C (+sooF+104°F) -30°C+60°C ( -22°F -+140°F) 2009 (7 oz) Type Q-8SD or Q-8SE Q-8SD: AC 100V:i:10% (50/60 Hz). AC 120V:i:10% (50/60 Hz). DC 11.5V-16.0V Q-8SE: AC 220V:i:10% (50/60 Hz). AC 240V:i:10% (50/60 Hz). DC 11.5V-16.0V 5 hours [at + 20°C ( + 68 OF), rated AC voltage or DC 15V] Temperature range Operatjon Storage Fuse Djmensions 0- +40°C (+32°F+104°F) -30°C+60°C ( -22°F -+140°F) 3Aglass tube fuse 130mm(L)x 45mm(W) x 80mm(H) (5.1"x1.8"x3.1") 400g (14.1 oz) Weight Wireless Function Keyboard Type FK.1 (Cordless. hand-held remote control keyboard) Transmission Range Angle Power source Operating time Temperature range Operatjon Storage Dimensions Weight 950nm infrared w ave 2m(7ft) 30° cone shaped Two 1.5 V M-type penlight batteries 30 hours (with full new batteries) -20°C+50°C ( -4°F -+122°F) -40°C+60°C ( -40°F -+140°F) 125mm(L)x80mm(W) x 25mm(H) (4.9Hx3.1Hx1.0H) 180g (6.3 oz) (including two batteries) K.K. Fuji Bldg., 2-3, Marunouchi Ø03.214.5311 Weight Smgon Telescape Tube length Effective diameter objective lens and 19on 44X Type Erect 3X O.5m (1.6ft)-oo 5° 400gon indexing Damping system Working range Setting accuracy (NTD-2) 10'/2mm NTD-2 360° reading (2.83in) 1° (NTD-4/NTD-3), of circular Recharging time Single 72mm 30"/2mm 40"/2mm mm steps) NTD-3 39X microscope Vertical circle Circle diameter Minimum increment Micrometer increment Digital presentation Sub-division dots Magnification of circle reading microscope Automatic 400gon Sensitivity level + Fahrenheit Opposite side reading 82 mm (3.23 in) 1° 19on 1° Digital presentation Sub-division dots Magnification of circle reading +122°F) +999mm(1 NTD-4 of plate Instrument (with handleandinternal battery pack) Atmospheric correction Sensitivity level : Ambient temperature 2.44ftl100ft) Levels Dimensions Distance unit 30X Erect 1°24' (2.44m/100m. 2.5* 1.3m(4.3ft) Built.in LED Magnification Image Field of view Resolving power Minimum focus Reticle illuminator Telex:J22601 3-chome, Chiyoda-ku, (NIKON) Printed in Japan HHAD.O2 KEC4o5'.10/1 Tokyo 100, Japan "GunJer.sen Il llkell.. -INSTRUMENTER Als. L-. [§]