CAPACITIES OMG SERIES ORIFICE METERS AIR & NATURAL GAS FLOW CAPACITY (SCFH) 100 – 200 Series Threaded / Weld-In 3/8" Through 1 ½" Pipe Size Pipe Size OMG Model Number 3/8" 103 1/2" 105 3/4" 107 1" 110 1 ¼" 112 1 ½" 115 Orifice Bore Size 0.197 0.232 0.266 0.307 0.350 0.232 0.266 0.317 0.368 0.423 0.273 0.324 0.379 0.437 0.508 0.585 0.324 0.384 0.452 0.523 0.613 0.715 0.456 0.533 0.630 0.735 0.850 0.986 0.533 0.635 0.744 0.867 1.005 1.156 Air 0.5" w.c.P 24 33 44 61 84 32 42 61 85 118 44 62 86 116 162 221 61 86 120 163 231 331 120 165 233 324 447 641 164 234 325 450 626 881 1" w.c.P 33 46 62 85 118 45 60 86 120 166 62 87 121 163 228 322 86 122 170 230 326 467 170 233 330 457 632 905 232 331 459 636 885 1245 Natural Gas 3" w.c.P 57 80 107 147 203 78 103 149 206 286 107 151 208 282 394 555 149 210 293 398 562 806 294 403 570 790 1092 1564 400 572 794 1100 1530 2151 5" w.c.P 73 103 137 189 261 100 133 191 265 368 137 194 268 363 507 714 192 270 378 513 724 1039 379 520 734 1018 1407 2015 516 737 1023 1417 1972 2771 0.5" w.c.P 30 42 57 78 108 41 55 79 109 152 57 80 110 149 208 294 79 111 155 211 297 427 155 213 301 418 577 827 212 302 419 581 808 1137 1" w.c.P 43 60 80 110 152 58 77 111 154 214 80 113 156 211 294 415 111 157 219 297 420 602 219 301 425 590 815 1168 299 427 593 821 1142 1607 3" w.c.P 73 103 137 189 262 100 133 192 266 369 137 194 269 363 508 716 192 271 378 513 725 1040 379 520 735 1020 1409 2018 517 738 1024 1419 1974 2776 5" w.c.P 94 132 177 244 336 129 171 247 342 475 177 250 346 468 654 921 247 349 487 661 935 1340 488 671 947 1314 1816 2600 666 951 1320 1829 2544 3576 Notes: 1. 2. 3. 4. 5. Orifice Bore Size Equals the Orifice Plate Inside Diameter. All Bore Sizes In Inches. Pipe Size Equals Schedule 40 Pipe. Capacity Based On 60°F @ 1 psig Upstream Pressure. Natural Gas Specific Gravity At 0.60; Air Specific Gravity At 1.0. 1__ Model Number Designates NPT Threaded Connection. 2__ Model Number Designates Weld-In Connection. All Flow Rates At Standard Barometric Pressure: 29.92" Hg (Sea Level) Design Capacity Is Based On 3" W.C.P. (OVER) In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. HAUCK MANUFACTURING CO., 100 North Harris Street Cleona, PA 17042 717-272-3051 4/14 www.hauckburner.com Fax: 717-273-9882 OMG-2 OMG SERIES ORIFICE METERS AIR & NATURAL GAS FLOW CAPACITY (SCFH) 100 – 200 Series Threaded / Weld-In 2" Through 6" Pipe Size Pipe Size OMG Model Number 2" 120 2 ½" 125 3" 130/230 4" 240 6" 260 Orifice Bore Size Air Natural Gas 0.5" w.c.P 1" w.c.P 3" w.c.P 5" w.c.P 0.5" w.c.P 1" w.c.P 3" w.c.P 5" w.c.P 0.640 0.754 0.875 1.034 1.203 1.375 0.754 0.890 1.048 1.236 1.423 1.625 0.894 1.056 1.252 1.452 1.688 1.963 1.261 1.470 1.722 2.029 2.345 2.691 1.735 2.067 2.437 2.879 3.314 3.850 4.388 238 334 455 650 911 1250 330 464 651 926 1266 1730 462 649 923 1262 1753 2483 919 1258 1748 2479 3418 4731 1729 2470 3468 4924 6685 9423 13055 335 470 640 914 1278 1753 465 652 916 1302 1778 2428 651 914 1300 1776 2466 3489 1295 1773 2462 3491 4810 6655 2439 3484 4890 6941 9420 13272 18381 577 808 1100 1568 2192 3003 800 1123 1576 2237 3053 4164 1122 1575 2237 3056 4238 5993 2234 3056 4242 6009 8275 11440 4211 6011 8434 11965 16231 22856 31638 743 1039 1415 2016 2817 3858 1030 1445 2027 2877 3925 5353 1444 2027 2879 3932 5452 7706 2877 3935 5461 7734 10648 14716 5425 7743 10863 15408 20897 29419 40712 307 430 586 836 1170 1605 425 597 838 1191 1628 2223 595 836 1188 1625 2256 3193 1184 1621 2251 3192 4400 6088 2229 3184 4469 6344 8611 12135 16809 432 605 824 1175 1644 2253 599 840 1180 1676 2288 3123 839 1178 1674 2287 3174 4491 1670 2285 3173 4497 6195 8568 3146 4493 6305 8947 12140 17101 23679 744 1041 1417 2019 2822 3865 1031 1447 2030 2881 3932 5362 1446 2030 2884 2938 5460 7719 2881 3941 5468 7746 10665 14741 5432 7754 10878 15429 20928 29466 40781 958 1339 1823 2597 3629 4967 1328 1863 2613 3707 5056 6894 1863 2614 3712 5068 7026 9929 3710 5075 7041 9971 13725 18966 6998 9988 14011 19870 26946 37931 52484 Notes: 1. 2. 3. 4. 5. Orifice Bore Size Equals the Orifice Plate Inside Diameter. All Bore Sizes In Inches. Pipe Size Equals Schedule 40 Pipe. Capacity Based On 60°F @ 1 psig Upstream Pressure. Natural Gas Specific Gravity At 0.60; Air Specific Gravity At 1.0. 1__ Model Number Designates NPT Threaded Connection. 2__ Model Number Designates Weld-In Connection. All Flow Rates At Standard Barometric Pressure: 29.92" Hg (Sea Level) Design Capacity Is Based On 3" W.C.P. In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. CAPACITIES OMG SERIES ORIFICE METERS AIR FLOW CAPACITY (SCFH) 2000 Series Weld – In 8" Through 16" Pipe Size Pipe Size OMG Model No. 8" 2080 10" 2100 12" 2120 14" 2140 16" 2160 Orifice Bore Size 3.272 3.874 4.562 5.268 5.788 4.095 4.944 5.770 6.514 7.241 4.90 5.80 6.90 7.80 8.70 5.70 6.80 8.00 9.10 10.10 6.50 7.80 9.20 10.50 11.60 Air Flow 0.5" w.c.ΔP 6247 8921 12772 17891 22737 9773 14550 20453 27159 35497 13975 19934 29179 38839 51176 18893 27396 39120 52796 68642 24550 36040 51776 70505 90725 1" w.c.ΔP 8814 12582 18006 25215 32038 13791 20527 28846 38295 50041 19727 28131 41166 54781 72168 26673 38668 55202 74486 96825 34665 50876 73073 99487 127999 3" w.c.ΔP 15209 21702 31044 43452 55193 23806 35418 49754 66030 86255 34061 48557 71029 94492 124444 46064 66258 95273 128517 167015 59874 87849 126139 171686 220835 5" w.c.ΔP 19591 27951 39975 55942 71044 30670 45623 64078 85025 111049 43886 62555 91489 121692 160237 59354 86009 122728 165526 215075 77153 113188 162499 221141 284403 6" w.c.ΔP 22441 30588 43744 61210 77729 33567 49929 70122 93038 121505 48033 68462 100122 133166 175332 64964 94133 134313 181139 235345 84446 123881 177841 242004 311213 8" w.c.ΔP 24715 35255 50412 70530 89552 38695 57551 80817 107215 139999 55372 78916 115398 153166 202031 74892 108511 154813 208761 271197 97354 142807 204990 278914 358633 10" w.c.ΔP 27586 39348 56260 78701 99915 43193 64235 90195 119644 156208 61810 88087 128795 171265 225432 83602 121123 172791 232980 302621 108678 159408 228799 311276 400196 Notes: 1. 2. 3. 4. Orifice Bore Size Equals The Orifice Plate Inside Diameter. All Bore Sizes In Inches. Pipe Size Is A Nominal Pipe ID. Capacity Based On 60°F @ 1 psig Upstream Pressure. Air Specific Gravity 1.0. All Flow Rates At Standard Barometric Pressure 29.92" Hg (Sea Level) Design Capacity Is Based On 3" W.C.ΔP. In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. (OVER) HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 9/98 www.hauckburner.com Fax: 717-273-9882 OMG-2.1 OMG SERIES ORIFICE METERS AIR FLOW CAPACITY (SCFH) 2000 Series Weld – In 18" Through 28" Pipe Size Pipe Size OMG Model No. 18" 2180 20" 2200 22" 2220 24" 2240 28" 2280 Orifice Bore Size 7.3 8.7 10.3 11.8 13.0 8.2 9.7 11.5 13.1 14.4 9.0 10.7 12.6 14.3 15.9 9.8 11.6 13.8 15.7 17.4 11.4 13.6 16.0 18.2 20.2 Air Flow 0.5" w.c.ΔP 30947 44758 64773 88932 113553 39066 55639 80801 109495 138946 47037 67703 96855 129987 169696 55748 79477 116254 157028 203519 75388 109262 155929 210302 273180 1" w.c.ΔP 43701 63191 91430 125508 160233 55170 78562 114066 154548 196092 66433 95604 136743 183492 239514 78740 112238 164144 221682 287280 106490 154318 220195 296938 385674 3" w.c.ΔP 75491 109131 157854 216631 276502 95311 135691 196959 266793 338437 114778 165141 236144 316802 413428 136051 193892 283487 382772 495930 184022 266618 380353 512805 665913 5" w.c.ΔP 97282 140616 203368 279049 356120 122826 174845 253758 343682 435913 147916 212800 304256 408124 532523 175337 249856 365266 493124 638812 237168 343589 490102 660689 857829 6" w.c.ΔP 106479 153903 222573 305381 389700 134439 191370 277725 376119 477025 161903 232913 332997 446651 582754 191918 273475 399773 539680 699076 259599 376073 536413 723079 938775 8" w.c.ΔP 122757 177420 256557 351967 449095 154993 220615 320137 433507 549746 186659 268510 383856 514815 671602 221266 315276 460837 622046 805668 299302 433565 6183645 833464 1081954 10" w.c.ΔP 137037 198048 286362 392813 501154 173025 246268 357332 483823 613486 208377 299736 428461 574580 749477 247012 351944 514391 694264 899096 334134 483996 690239 930249 1207453 Notes: 1. 2. 3. 4. Orifice Bore Size Equals The Orifice Plate Inside Diameter. All Bore Sizes In Inches. Pipe Size Is A Nominal Pipe ID. Capacity Based On 60°F @ 1 psig Upstream Pressure Air Specific Gravity 1.0. All Flow Rates At Standard Barometric Pressure: 29.92" Hg (Sea Level). Design Capacity Is Based On 3" W.C.ΔP. In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. DIMENSIONS OMG SERIES ORIFICE METERS (NOT TO SCALE) X1497 100 SERIES THREADED DESIGN In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 8/06 www.hauckburner.com Fax: 717-273-9882 OMG-3 (NOT TO SCALE) X1499 DIMENSIONS OMG 200 SERIES WELD-IN DESIGN In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. DIMENSIONS OMG SERIES ORIFICE METERS (NOT TO SCALE) X3305 2000 SERIES AIR ONLY WELD-IN DESIGN In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 8/12 www.hauckburner.com Fax: 717-273-9882 OMG-3.1 OMG SELECTION CHART NATURAL GAS (SCFH) @ 3" W.C. ΔP SUPPLEMENTAL DATA In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 9/98 www.hauckburner.com Fax: 717-273-9882 OMG-4 OMG SELECTION CHART NATURAL GAS (SCFH) @ 3" W.C. ΔP In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. OMG SELECTION CHART AIR (SCFH) @ 3" W.C. ΔP SUPPLEMENTAL DATA In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 9/98 www.hauckburner.com Fax: 717-273-9882 OMG-4.1 OMG SELECTION - AIR (SCFH) @ 3" W.C. ΔP In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. SUPPLEMENTAL DATA OMG SELECTION CHART 2000 SERIES – AIR SERVICE (SCFH) @ 3" W.C. ΔP In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 9/98 www.hauckburner.com Fax: 717-273-9882 OMG-4.2 APPLICATION DATA OMG SERIES ORIFICE METERS CORRECTING FOR CONDITIONS OUTSIDE CATALOG PARAMETERS The capacities listed in OMG-2 and OMG-2.1 are cataloged at 60°F and 1 psig upstream pressure (specific gravity for air at 1.0, natural gas 0.60). When these conditions are not present, corrections must be applied to the catalog flow rate. Upstream Pressure For an upstream pressure other than 1 psig, obtain the appropriate correction factor for upstream pressure, then determine the corrected flow as shown. (1) p2 + 14.7 Cpress= p1 + 14.7 Cpress= Upstream Pressure Correction Factor p1 = Cataloged Upstream Pressure (1 psig) p2 = Actual Upstream Pressure (psig) (Note: 1psig = 27.7" W.C.) Table 1 p2(psig) Cpress 0.5 .98 1.0 1.0 1.5 1.01 2.0 1.03 3.0 4.0 5.0 10.0 1.06 1.09 1.12 1.25 Multiply the pressure correction factor, Cpress, by the flow determined from the OMG capacity table to obtain the corrected flow. For example, an OMG 115 with a .744" orifice has a capacity of 1024 SCFH natural gas at 3" ΔP. For a 2 psig upstream pressure, the corrected flow will be 1024 SCFH X 1.03 = 1055 SCFH. Specific Gravity For a specific gravity other than 0.60 (natural gas) or 1.0 (air), use FORMULA 2 or TABLE 2 to obtain the appropriate specific gravity correction factor, then determine the corrected flow as shown. Table 2 (2) Cs.g.= s.g.1 s.g.2 Cs.g. = Specific Gravity Correction Factor s.g.1 = Specific Gravity - Natural Gas (0.60) s.g.2 = Specific Gravity - Actual Gas Gas s.g. Cs.g. Coke Oven 0.40 1.22 Natural 0.60 1.0 Air 1.0 .77 Propane 1.52 .63 Butane 2.01 .55 Multiply the s.g. correction factor, Cs.g., by the flow determined from the OMG capacity table to obtain the corrected flow. For example, an OMG 115 with a .744" orifice has a capacity of 1024 SCFH natural gas at 3" ΔP. For propane, the corrected flow will be 1024 SCFH X 0.63 = 645 SCFH. Temperature For a gas temperature other than 60°F, use FORMULA 3 or TABLE 3 to obtain the appropriate temperature correction factor, then determine the correct flow as shown. (3) Ctemp= Abs Temp1 Abs Temp2 Ctemp = Temperature Correction Factor Abs Temp1 = t1 + 460 Abs Temp2 = t2 + 460 t1 = Catalog Temperature (60oF) t2 = Actual Temperature (oF) Table 3 Temp., °F Ctemp 50 1.01 60 1.0 80 .98 100 150 200 250 .96 .92 .88 .85 Multiply the temp. correction factor, Ctemp, by the flow determined from the OMG capacity table to obtain the corrected flow. For example, an OMG 115 with a .744" orifice has a capacity of 1024 SCFH natural gas at 3" ΔP. For a natural gas temperature at 100°F, the corrected flow is 1024 SCFH X .96 = 983 SCFH. Note: If more than one correction factor is necessary, simply multiply the cataloged flow by each of the correction factors. For all the correction factors shown above, the corrected flow will be 1024 SCFH X 1.03 X 0.63 X 0.96 = 638 SCFH. HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 3/02 www.hauckburner.com Fax: 717-273-9882 OMG-7 Non Cataloged Differential Pressure And/Or Flow To calculate differential pressure and/or flow not listed in the OMG Capacity Tables, use the Square Root Law, Formula 4 and 5 as shown below. (4) Q2= Q1 p2 p1 Q2 = Unknown Flow (SCFH) @ p Q1 = Catalog Flow (SCFH) @ p 1 p2 = Actual Pressure p @ Q 2 p1 = Catalog Pressure p @ Q 1 2 (5) p2= p1 Q2 Q1 p @ Q2 ("w.c.) p2 = p1 = Catalog p @ Q1 ("w.c.) Q2 = Desired Flow @ p2 (SCFH) Q1 = Catalog Flow @ p1 (SCFH) For example, an OMG 115 with a .744" orifice has a flow capacity of 1024 SCFH natural gas at 3" w.c. Δp, 1 psig upstream pressure and 60°F. To determine the flow at 4.3" w.c. Δp, plug the known variables listed below into formula 4. Q2 = unknown Q1 = 1024 SCFH p2 = 4.3" w.c. Δp p1 = 3.0" w.c. Δp Solving Formula 4, for Q2, the natural gas flow is 1226 SCFH. For example, an OMG 115 with a .744" orifice has a flow capacity of 1024 SCFH natural gas at 3" w.c. Δp , 1 psig upstream pressure and 60°F. To determine the Δp for a flow of 775 SCFH, plug the known variables listed below into formula 5. p2 = unknown p1 = 3" w.c. Δp Q2 = 775 SCFH Q1 = 1024 SCFH Solving Formula 5 for p2, the natural gas Δp is 1.71" w.c. SAMPLE OMG SELECTION PROBLEM Select an orifice meter to measure 925 cubic feet per hour natural gas at 3" w.c. pressure drop across the orifice meter. The meter shall be installed in 1 ½" threaded, scheduled 40 pipe. The specific gravity of the gas is 0.60 with an upstream pressure of 1 psig and temperature of 60°F. Using the capacity table OMG-2, select natural gas and 1 ½ " pipe size. Next, select the 115 model number for threaded connections. Then, look in the 3" w.c. Δp column and find the flow that is closest to 925 cubic feet per hour. In this case, the closest available orifice bore is 0.744" which has a natural gas flow capacity of 1024 SCFH. Select an OMG-115 with a 0.744" orifice. To calculate the actual Δp at 925 SCFH, use formula 5.
Similar documents
B42 Series Regulator
B- Change in outlet pressure for 10 PSIG inlet pressure change C- Outlet pressure increase required for lock up
More information