feeling cool - SIFEE Action
Transcription
feeling cool - SIFEE Action
feeling cool WSAT-2 SERIES CHILLERS from 200-1500 KW The CLIVET chillers WSAT-2 series have air cooled condenser with axial low speed fans. They are equipped with semi-hermetic single screw compressors using R-407c ecological refrigerant agent. The electrical circuitry , the control unit equipped with microprocessor and the LCD display are all integrated under the chiller weatherproof casing. The case is made of galvanised steel and protected by a thermic treated resin, painted in electrostatic field, therefore is included in IP 45 protection class. The WSAT-2 chillers are configurable with 2,3 or 4 independent refrigerant circuits for redundancy. Each circuit is equipped with his compressor, expansion valve, solenoid valve, drying filter with detachable core, closing valve, lubricating device, injection circuit, safety valve and manometers for high and low pressure. HEIGHT (H) R-407c ECOLOGICAL REFRIGERANT AGENT LE NG HT ( L) WI DT w) H( DEUTSCHER AKKREDITIRUNG RAT E N U N I - I S O 9 0 0 1 DAIKIN SINGLE SCREW COMPRESSOR EN UNI - ISO 9001 NATIONAL ACCREDITATIONS OF CERTIFICATION BODIES The single screw compressor developed by DAIKIN uses ecological refrigerant agent and, beside the high tecnology level it has a compact, simple and solid construction. Due to the lack of valves and critical reciprocity elements the compressor has an increased resistance at liquids pressure shocks and therefore results a high reliability. Th compressor has a perfect balance between the axial and radial forces due to the symmetrical compression with a single rotor and 2 gears. The internal contact pressure is very low and the gears made of a special composed material determine the decrease of detrition and energy loss. The lubricating pump is unnecessary because the compressor is cooled by the freon’s circulation. The single screw design (without primers and alternate movements) determines a very low detrition and noise level. The service interventions for oil changing are necessary only after 40.000 hours of continuous operation. ORDERING CODE: WSAT-2 R 2. 240 LN T D APPROVALS: SERIE WSAT-2 C= CLIVET - internal I= ISPEL - Italy D= TUV - Germany S= S.A. - Sueden F= SDM - France E= MIE - Spain T= TTK - Finland R-407C refrigerant TOTAL COMPRESSORS POWER (HP) VERSIUNI S = Standard R = Total heat recovery D = Partial heat recovery B = Brine Chiller CONFIGURATION ST = Standard LN = low noise APLICATIONS: T = temperate climate H = high efficiency NUMBER OF COMPRESSORS CHILLER CLIVET WSAT 2.90 2.100 2.110 2.125 2.140 2.155 2.170 2.200 2.230 2.260 2.280 2.300 2.330 2.360 Cooling power (1) 202 246 271 288 309 339 367 416 482 538 592 642 691 741 kW 76 88 98 107 117 133 141 164 189 216 237 260 291 321 Max current load (2) A 177 206 234 250 265 299 314 363 409 455 511 567 658 750 Max start current (2) A 273 330 363 393 409 491 506 561 651 702 813 874 1023 1144 106 122 139 149 159 180 190 220 249 278 308 338 372 406 35 42.5 46.8 49.7 53.3 58.3 63 71.6 82.8 92.5 102 111 120 128 kW Compressors electrical power (1) Max total electrical power(3) kW 3 m /h Water flow (1) 3 Air flow m /s 24.9 30 35.2 34.9 34.6 41 40.4 44.6 51.8 55.8 63.4 67.2 65.5 64 Static pressure (1) kPa 32.4 25 30.1 28.9 33.3 22.0 25.7 31.4 32.6 32.3 32.4 31.7 31.9 31.3 Noise level ST(4) dB(A) 81 81 82 82 82 82 83 83 83 83 84 84 84 84 Noise level LN(4) dB(A) 73 73 73 74 74 74 75 75 75 76 76 76 76 76 Noise level EN(4) dB(A) 67 67 67 67 68 68 68 68 69 69 69 69 69 69 Total weight Kg 2727 2969 3194 3285 3330 3647 3733 Dimensions L x W x H 3950x2040x2104 mm 3943 4370 4551 5142 5620 5776 5932 3950x2326x2443 4880x2326x2443 5900x2326x2443 3.390 3.410 3.430 3.450 3.480 3.510 3.540 4.580 4.600 4.630 4.660 4.690 4.720 CHILLER CLIVET WSAT 810 855 912 963 1013 1064 1112 1181 1234 1285 1334 1383 1482 kW 319 345 367 390 418 448 478 476 498 521 551 582 642 Max current load (2) A 684 736 792 848 940 1031 1123 1074 1130 1221 1313 1405 1496 Max start current (2) A 962 1064 1125 1186 1364 1456 1548 1437 1498 1677 1768 1860 1951 Max total electrical power(3) kW 420 448 478 508 542 576 610 647 677 711 745 779 812 m3/h 139 146 156 165 174 182 191 203 212 221 229 237 252 3 m /s 90 89.4 97 101 103 101 100 130 134 132 131 129 128 kPa 34 33.1 33.2 32.9 32 31.3 30.6 30.4 30.4 29.9 29.4 29 30.5 Noise level ST(4) dB(A) 85 85 85 85 86 86 86 87 87 87 87 87 87 Noise level LN(4) dB(A) 77 77 78 78 78 78 78 79 79 79 79 79 79 Noise level EN(4) dB(A) 71 71 71 72 72 72 72 73 73 73 73 73 73 6708 7044 7324 7790 8622 8788 kW Cooling power(1) Compressors electrical power (1) Water flow (1) Air flow Static pressure (1) Total weight Kg Dimensions L x 2326 x 2443 mm SUPPLY POWER STANDARD 400V /3~/ 50 Hz DEALER: 7918 8938 8954 10171 10580 10755 10916 11079 11251 11790 9840 (1) test conditions: water evaporating at 12/7°C -room temp 35°C (2) data for the entire unit (3) in maximum admisable conditions (4) the noise level ins measured at 1m distance from the unit placed in open space The manufacturer reserves his right to do small changes of nominal parameters EVERY CHILLER IS TESTED BEFORE DELIVERY IN SPECIALS STANDS, IF THEY ARE OPERATING AT THE NOMINAL PARAMETERS FROM THE TABEL ABOVE. MANUFACTURER: CLIVET s.p.a. - Z.I. 32030 VILLAPAIERA - FELTRE(BL) Italy