Horton Automatics Interactive Product Selection Guide
Transcription
Horton Automatics Interactive Product Selection Guide
Horton Automatics Interactive Product Selection Guide TABLE OF CONTENTS Automatic Sliding Doors .............................................................................................................................................................. 3 Profiler® Series 2000B Elite Belt Drive ............................................................................................................................ 3 Profiler® Series 2000 Linear Drive .................................................................................................................................. 3 ProSlide® Series 2003 Belt Drive .................................................................................................................................... 3 ProSlide® series 2003 SA Belt DrivE ................................................................................................................................ 3 ProSlide® Series 2003 telescoping Belt Drive ................................................................................................................. 3 HD Series 2001 Belt Drive ............................................................................................................................................... 3 HD Series 2500 All Glass Elegant® .................................................................................................................................. 4 Automatic Swinging Doors (also known as full power doors) ..................................................................................................... 5 Low Energy Swinging Doors......................................................................................................................................................... 6 Automatic Folding Doors ............................................................................................................................................................. 7 Revolving Doors ........................................................................................................................................................................... 8 Series 9600 Grand® Revolving Door ............................................................................................................................... 8 Series 9600 MiniGrand® Revolving Door ........................................................................................................................ 8 Series 9300 AutoFlow® ................................................................................................................................................... 8 Series 9200/9100 Control Flow® .................................................................................................................................... 8 Series 9500 Easy Flow®................................................................................................................................................... 9 ICU / IMU / CCU / Isolation Room Doors (Systems For Health Care)…………………………………………………………………………………….10 ® Profiler-ICU .................................................................................................................................................................. 10 ICU/CCU Bi-Fold/Bi-Swing™.......................................................................................................................................... 10 Profiler Telescoping-ICU .............................................................................................................................................. 10 Profiler Self-Closing Smoke-rated ICU ......................................................................................................................... 10 Profiler-ICU® Smokeswing™ ......................................................................................................................................... 10 ® ® Horton Automatics | Automatic Sliding Doors 1 Profiler® Smoke-rated ICU/CCU doors with mini-blind glass ....................................................................................... 10 Profiler® Smoke-rated telescoping ICU/CCU ................................................................................................................ 11 Profiler® Smoke-rated single slide P-X/X-P ICU/CCU .................................................................................................... 11 2000-IDS Automated ICU/CCU Isolation Door System ................................................................................................. 11 Drive-Thru Service Windows ..................................................................................................................................................... 13 Industrial Sliding Doors .............................................................................................................................................................. 13 RapidSlide® ................................................................................................................................................................... 13 HD Slide® with Hollow Metal Panels ............................................................................................................................ 13 Hd Slide® with Aluminum & Glass panels ..................................................................................................................... 13 UltraClean™ Atmospheric/Sterile ................................................................................................................................. 13 Door Construction ..................................................................................................................................................................... 14 Finishes ...................................................................................................................................................................................... 14 Quality Assurance and Code Compliance .................................................................................................................................. 15 Installation Considerations ........................................................................................................................................................ 15 Design Life ................................................................................................................................................................................. 15 General: Horton Automatics manufactures a variety of automatic pedestrian doors. This selection guide is intended to acquaint architects, specification writers and owners with the various Horton products available and the process involved in selecting an appropriate automatic door. Please refer to the Horton glossary for the proper definition of terms with which you may not be familiar. TYPES OF DOOR SYSTEMS There are six types of door systems available from Horton including Sliding, Full Power Swing, Low Energy Swing, Automatic Folding, Revolving and Manual Intensive Care/Critical Care Unit doors. In addition, we offer a line of Drive-Thru Service Windows both in manual and automatic configurations as well as a line of Industrial Sliding Doors. The Horton Automatics industrial line includes exclusive pneumatic and explosion proof operators. Horton Automatics | Automatic Sliding Doors 2 AUTOMATIC SLIDING DOORS The automatic sliding door is a very efficient way to accommodate simultaneous two-way traffic flow. It can also be used very effectively in controlling directional traffic situations such as one door for entry-traffic and another for exit-traffic – this is the typical set up of large retail establishments. When a vestibule air lock is considered, the distance between door banks should be a minimum of 9 feet (12 feet is preferred) to provide an adequate detection zone for the activation sensors. Automatic sliding doors are available in single, bi-part and telescopic slide configurations. These are furnished as complete standard packages or can be surface mounted or overhead concealed. Slide doors typically include an operator, a header track, a lock, carrier wheels, sliding door panel(s), sidelite panel(s), jambs, and activation/safety system. Door systems can be designed for full breakout (all panels break out for emergency egress) or partial breakout. Multiple finish options and custom designs are also available. Horton offers five drive mechanisms: PROFILER® SERIES 2000B ELITE BELT DRIVE This 4” x 6” header is a Horton exclusive. The slim design maintains harmony with store fronts which are typically 4” or 4.5” in depth providing attractive sightlines. The 2000B system is available in single slide configurations ranging from 7 to 9 feet and bi-part configurations ranging from 8 to 16 feet. In addition, the Series 2000 header is utilized in Horton’s hurricane packages and is Miami-Dade approved for design pressures up to ±55 PSF. Click here to review the specifications and here to view the architectural details. PROFILER® SERIES 2000 LINEAR DRIVE In addition to the benefits listed above, the Linear Drive is a Horton exclusive design in which a travel block with a built-in clutch describes a helical path along a ½” stainless steel rod to open and close the door panels. There are fewer moving parts and wear items resulting in a quiet and dependable system. The 2000 Linear Drive system is available in single slide configurations ranging from 7 to 9 feet and bi-part configurations ranging from 8 to 16 feet. Just as the 2000B, the Linear Drive is Miami-Dade approved for design pressures up to ±55 PSF. Click here to review the specifications and here to view the architectural details. PROSLIDE® SERIES 2003 BELT DRI VE The ProSlide® is ideal for high traffic applications. This heavy duty belt drive system is engineered to provide long life and quiet operation. Click here to review the specifications and here to view the architectural details. PROSLIDE® SERIES 2003 SA BELT DRIVE This system shares the power train and header design of the ProSlide® 2003 and its panel hanger brackets are designed for surface mounting as opposed to overhead concealed mounting. PROSLIDE® SERIES 2003 TELESCOPING BELT DRIVE This system utilizes the Series 2003 power train in a single telescoping configuration. Click here to review the specifications and here to view the architectural details. HD SERIES 2001 BELT DRIVE The HD Slide boasts an 8” x 8” mammoth header that houses a powerful system designed for large heavy commercial and industrial applications. The HD is the mechanism of choice for all glass Elegant® entrances as well as platform screen doors for people mover systems. The HD Series uses the same power train as the HD Storm hurricane-rated system and is Miami-Dade approved for design pressures up to ±80 PSF. The HD Storm is the highest rated, Horton Automatics | Automatic Sliding Doors 3 largest envelope hurricane door system on the market. Click here to review the specifications and here to view the architectural details. HD SERIES 2500 ALL GLAS S ELEGANT® The frameless styling of the Elegant® series adds distinction to your facility by showcasing the inner beauty of a building while offering the advantages of automatic operation and energy conservation. Single slide configurations are available in ranges from 7 to 9 feet and bi-part configurations ranging from 9 to 14 feet. These systems come standard with ½” clear tempered glass. Click here to review the specifications and here to view the architectural details. System Handing and Mounting Options Back to Table Of Contents Horton Automatics | Automatic Sliding Doors 4 AUTOMATIC SWINGING DOORS (ALSO KNOWN AS FULL POWER DOORS) The automatic swinging door is normally used for directional or one-way pedestrian traffic. Typically, one door is used for ingress and another for egress. Horton does not recommend the use of automatic swinging doors for two-way traffic applications for full power applications. When exceptions are made, the application must be well planned in consultation with experienced designers with perhaps a remote switch/push plate to activate the door well in advance of an approach. The key issue is synchronizing the activation and safety sensors to ensure smooth traffic flow is achieved. When a vestibule air lock is considered, the distance between door banks should be a minimum of 9 feet (12 feet is preferred) to provide an adequate detection zone for the activation sensors. Horton recommends the use of an aluminum swing door panel when a Horton Automatics operator Series S4000 or S7000 is utilized. This practice ensures that the door is constructed to accommodate the demand of automatic applications. Design professionals often find that supplying an operator for use on existing doors is generally limited to applications where the need to closely match adjacent entrances in the area is critical or when fire rated doors are under consideration. Automatic full-power swing doors can either be supplied as complete packages, or simply as the operator with header and drive arms. These systems may also be mounted as overhead-concealed operators for direct drive applications or surface mounted for push and pull applications. Automatic swing door products are designed for single, pair or double egress applications. Singles and Pairs Double Egress When supplied as a complete package, this will generally include an operator, a header, a lock, door panel(s), jambs, guide rails, electronic activation/safety system and all applicable safety hardware. When existing door panels are utilized, then an operator with header and drive arms are supplied along with an appropriate activation and safety system. In all instances, guide rails may be required to protect the swing area of the door panel(s). If the doors swing against a natural barrier such as a wall, the guide rails may be removed from consideration. Click here to review the specification and here to view the design sheet. Explosion proof pneumatic swing operators are also available for industrial applications. Back to Table Of Contents Horton Automatics | Automatic Swinging Doors (also known as full power doors) 5 LOW ENERGY SWINGING DOORS Low-energy swinging doors provide accessibility for the physically challenged while allowing other pedestrians to use the door as a normal manual swinging door. Typically, low-energy operators are applied to existing doors in order to meet Americans with Disability Act (ADA) requirements. Examples of typical applications include hospital bathrooms and revolving door entrances. Automatic low-energy swinging door operators are designed for applications requiring ADA compliance. These operators are available in single pair or double egress configurations. This type of operator is usually activated with push plates (the industry defines this as “knowing act activation”). The unit includes a header, an operator and a drive arm. Because the door moves at an intrinsically safe speed, safety sensors are not required by code. Some users require extra sensors for added protection (this is not required and does not affect the safe operation of the low energy entrance). Horton Automatics offers two Low Energy Swing Systems: Heavy Duty HD 4000LE Easy Access® Series 7100 Low Energy Back to Table Of Contents Horton Automatics | Low Energy Swinging Doors 6 AUTOMATIC FOLDING DOORS Folding doors are a space saving solution where the opening width is restricted to approximately 6 to 8 feet and there is a need to move traffic in both directions. Folding doors are a sound choice in narrow corridors as it maximizes the opening path (85% of the total wall-to-wall width can be used as a walkway). Single fold doors are best suited for directional or one-way traffic, whereas bi-fold doors are best suited for two-way traffic. Automatic folding doors are furnished as complete packages that typically include an operator, a header, a lock, pivot hardware, door panels, guide rails, and activation/safety system. These systems are offered in either single fold or bi-fold configurations. Back to Table Of Contents Horton Automatics | Automatic Folding Doors 7 REVOLVING DOORS Manual and automatic revolving doors can be used for high-traffic applications requiring simultaneous entry and exit or controlled access. Revolving doors have the advantage of reducing the amount of air exchanged from the building to the outside and vice versa, creating an air lock that helps manage energy use and utility expenses. This occurs as the rotating wings do not allow for the direct flow of air to go through the entrance, effectively acting as an “always opened, always closed” entrance. Empirical studies (MIT et al) indicate that the amount of air that can be exchanged through a revolving door is less than 10% of what is exchanged through a swing or slide entrance. This phenomenon translates into significant savings in energy consumption and CO 2 emissions. In areas of high wind and high humidity, savings are particularly substantial, resulting in a payback of months. Horton has developed an interactive simulation tool that allows owners and facility managers to assess the savings in Kilowatt/Hour, CO2 reduction and air conditioning equipment – please call us for a FREE energy assessment of your entrance. Conversely, you can utilize FREE of charge the Horton Energy, CO2 Savings and Payback simulation software and see for yourself the results. Horton automatic and manual revolving doors are manufactured as complete packages in virtually any finish the specifier desires. Horton offers three-wing and four-wing designs. Smaller doors have center shaft drive systems. Larger doors also offer center core displays. Systems under 9 feet in diameter are typically offered for security and controlled access applications. All Horton revolving doors are factory-equipped with all necessary activation and safety systems for safe operation and code compliance. SERIES 9600 GRAND® REVOLVING DOOR Offered in diameters ranging from 12 to 16 feet, this system offers spacious compartments and provides an elegant and energy efficient entrance capable of handling large volumes of pedestrian traffic as well as shopping carts, bicycles, wheel chairs and hospital stretchers. The Grand® is typically designed in three-wing configuration with round or segmented drum and canopy combination. The Grand® revolver comes with a center core which is an ideal promotional display and is capable of handling up to 45 people per minute. Click here to review the specifications and here to view the architectural details. SERIES 9600 MINIGRAN D® REVOLVING DOOR Offered in diameters ranging from 11 to 12 feet, this system has the same construction of the Grand with a center shaft as opposed to the center core of the Grand. All options available with the Grand® are available with the MiniGrand® including activation and safety systems. The MiniGrand® is capable of handling up to 40 people per minute. Click here to review the specifications and here to view the architectural details. SERIES 9300 AUTOFLOW® This hands-free entrance system offered in a 10 foot diameter (9 feet is also available for foreign countries) has a reduced speed feature that slows the rotation for wheelchairs, strollers and other forms of slower traffic. This series is offered in either a 3 or 4 wing configuration with a curved or segmented drum. Click here to review the specifications and here to view the architectural details. SERIES 9200/9100 CONTROL FLOW® The Control Flow® is available in 1 - way, 1-way airport, 2-way card access, anti-piggyback/anti-tailgate and object detection security packages all with user selectable security levels. Level III bullet resistant glazing and mat-less activation is also available. The Control Flow® is the ultimate protection for financial institutions, government offices, laboratories and any other facility where security is paramount. The Control flow® is factory-equipped with all the necessary safety, security, hardware and application-specific sensors and delivered in your choice of finish. Diameters Horton Automatics | Revolving Doors 8 range from 6 feet 6 inches to 12 feet depending on the application. Click here to review the specifications and here to view the architectural details. SERIES 9500 EASY FLOW ® Offered in diameters ranging from 6 to 8 feet (up to 9 feet for foreign countries), this is an outstanding choice for energy efficiency and architectural appeal. Each system is equipped with a speed control that limits the rotational speed of the system for safe operation and bookfold hardware for emergency egress. This system is available in 3 or 4 wing configurations in curved or segmented drum and canopy design with your choice of multiple finishes. Click here to review the specifications and here to view the architectural details. Grand® MiniGrand® Control Flow® 2- Way Card Access Control Flow® 1-Way Control Flow® Airport Security Back to Table Of Contents Horton Automatics | Revolving Doors 9 ICU / IMU / CCU / ISOLATION ROOM DOORS Horton offers the industry leading broadest line of intensive, intermediate, and critical care (ICU, IMU, CCU) door systems on the market today. System packages include sliding, swinging, bi-fold/bi-swing, and telescoping. Smoke-rated configurations including self-closing, swing and slide including mini-blind glass, telescoping, and P-X systems with options such as narrow, medium and wide stile. Muntins are optional for all smoke-rated systems. Innovative non-smoke rated options include self-closing and isolation room systems. Click here for specification and architectural details of the Horton ever expanding line of health care solutions. PROFILER-ICU Offered in 2, 3 and 4 panel configurations, this system is available in single slide unit widths ranging from 7 to 9 feet. The single slide is also available with a first-to-market powerless self-closing option where codes and hospital personnel demand it. Bi-parting units ranging are also available for openings ranging from 8 to 16 feet. The multi-access track or trackless design allows for clear monitoring of a room and full breakout capability is standard for easy movement of patients and medical equipment. Click here to review the specifications and here to view the architectural details. ® ICU/CCU BI-FOLD/BI-SWING™ Offered in unit widths ranging from 6 to 8 feet, this system has a swing door for normal two way traffic and an adjacent bi-fold door that creates additional clearance for easy movement of patients and equipment. The fold swing opening ranges from 4′ 8″ to 6′ 8″ and the breakout opening ranges from 4′ 11″ to 6′ 11″. Click here to review the specifications and here to view the architectural details. PROFILER TELESCOPING -ICU Offered in unit widths ranging from 7 to 12 feet, this system is ideal for moving patients and critical medical care equipment without the need to breakout the doors. It comes with the option of a recessed door handle or positive latching. Slide openings range from 4′ 4″ to 7′ 8″ with track or trackless options available. Systems come standard with full breakout capability. Click here to review the specifications and here to view the architectural details. ® PROFILER SELF-CLOSING SMOKE -RATED ICU This first of its kind fully concealed self-closing smoke-rated system is available in single slide configurations ranging from 7 to 9 feet in width. The door easily opens like the Profiler-ICU® and self-closes without user intervention. The system can be equipped with either a positive latch or magnet to latch based on government codes. The system comes standard with a mechanical hold open device for times when hospital personnel would like to leave the door open. An electromagnet hold open option is available for customers that want the assurance that the door closes while open if a fire alarm is triggered. Slide openings range from 2′ 87/8″ to 3′ 8-7/8″ with track or trackless options available. Systems come standard with full breakout capability. Click here to review the specifications and here to view the architectural details. ® PROFILER-ICU® SMOKESWING™ Available in single, equal, unequal pair configurations with no center muntins required, these smoke-rated swing door systems allow greater flexibility in designs where space may be an issue. Unit widths available for single units range from 3′ 1-1/2″ to 4′ 3-1/2″, equal pairs (6′ 3-1/2″ to 8′ 3-1/2″) and unequal pairs (5′ 3-1/2″ to 6′ 3-1/2″) giving an architect or specifier great latitutude when constraints exist. Click here to review the specifications and here to view the architectural details. PROFILER® SMOKE -RATED ICU/CCU DOORS WITH MINI-BLIND GLASS With increasing demand for patient privacy, and healthcare facilities always looking for ways to reduce the risk of nosocomial Horton Automatics | ICU / IMU / CCU / Isolation Room Doors 10 infections, Horton offers smoke-rated ICU slide and swing doors with mini-blind glass. The slide package comes in unit sizes ranging from 2′ 8-7/8″ to 3′ 8-7/8″ with breakout openings ranging from 6′ 3″ to 8′ 3″. The swing package comes in sizes ranging from 5′ 3-1/2″ to 7′ 3-1/2″ with swing openings ranging from 4′ 7″ to 6′ 7″. Systems are trackless and can be specified with a fire-rated panel (to meet square footage requirements where codes apply) or with mini-blind glass from top to bottom. Systems come standard with positive latching. Click here to view the marketing brochure. PROFILER® SMOKE -RATED TELESCOPING IC U/CCU The first-to-market smoke-rated telescoping system offers up to 78% greater opening width than a standard smoke-rated single slide system. The system comes in standard sizes ranging from 7 to 12 feet and slide openings ranging from 3′ 4-1/4″ to 6′ 8-1/4″. The breakout opening (6′ 1″ to 11′ 1″) allows for greater flexibility in the event of a critical situation. Systems can be specified in track or trackless designs for unobstructed traffic flow. Systems come standard with positive latching. Click here to review the specifications and here to view the design sheet. PROFILER® SMOKE -RATED SINGLE SLIDE P -X/X-P ICU/CCU The first-to-market smoke-rated P-X/XP system offers distinct beauty for architects who are looking to transform their healthcare designs. The sliding panel rolls on a nylon track for a smooth and quiet operation. Available in unit widths ranging from 7′ 6″ to 11′ 3-1/8″ and slide openings ranging from 3′ 1/4″ to 5′ 3/8″ this system meets all the needs of a standard ICU with no breakout needed. For aesthetic purposes, this system can be specified with or without cart bars. Click here to review the specifications and here to view the design sheet. 2000-IDS AUTOMATED ICU/CCU ISOLATION DOOR SYS TEM Driven by healthcare risks associated with tuberculosis and immunocomprimised patients exposed to bacteria such as aspergillus, this system allows hospital personnel to quarantine high risk patients and reduce the risk of a potential epidemic. Designed with the Profiler 2000 header system, the isolation door system ensures positive latching each time the door is closed. Gasketing is utilized around the perimeter of the door to ensure a strong seal when utilized in positive and negative pressure rooms. Wall mounted push plates or infrared sensors are used to open or close the door. Call the factory for details at Horton 800.531.3111 x. 103 Horton Automatics | ICU / IMU / CCU / Isolation Room Doors 11 Packages With Bottom Guides Trackless Packages Horton’s product line is in constant evolution – contact us for the latest information. Back to Table Of Contents Horton Automatics | ICU / IMU / CCU / Isolation Room Doors 12 DRIVE-THRU SERVICE WINDOWS Service windows are ideal for restaurants, pharmacies, hospitals and any other facilities that use drive thru’s to enhance the overall customer service experience. These systems can be customized with transaction drawers including up to 1″ insulated glass, bullet resistant glass, with or without security locks, multiple finishes and activated manually or automatically. These systems are available in 2 panel design from 48″ to 50¼″ and 4 panel designs up to 53½″. INDUSTRIAL SLIDING DOORS With a maximum 12 foot stroke and 500 pound weight capacity, industrial door systems are engineered for ruggedness. Typical installations include warehouses, pharmaceutical and biotechnology manufacturing, food processing, clean rooms as well as other sterile environments. These doors systems are offered in P-X, X-P or PX-X-P configurations and are also available with pneumatic and/or explosion proof operators. RAPIDSLIDE® is a light weight steel door system that uses Polyurethane filled Thermacore® panels for maximum energy efficiency. The RapidSlide® is available in unit widths ranging from 13’ 2″ to 25’ 2″ with a maximum slide opening of 6 to 12 feet. Click here to review the specifications and here to view the architectural details. HD SLIDE® WITH HOLLOW METAL PANELS This heavy duty industrial system uses 18 or 20 gauge galvanized steel skin door with a Kraft honeycomb core. The interior framing channels utilize 14 gauge steel. The panels have a flush clean design with no exposed fasteners. This system is available in unit widths ranging from 11’ 3″ to 21’ 3″ with a maximum slide opening of 5 to 10 feet. Click here to review the specifications and here to view the architectural details. HD SLIDE® WITH ALUMINUM & GLASS PANELS This full view system is offered in a 5” wide medium stile and a 6-½” bottom rail. This system is available in unit widths ranging from 9’ 2″ to 21’ 2″ with a maximum slide opening of 4 to 10 feet. Click here to review the specifications and here to view the architectural details. ULTRACLEAN™ ATMOSPHERIC/STERILE These systems are designed for Class 1 (electronic) clean room applications. This system features a positive seal, vinyl weatherstrip and touchless wall mounted scanner activation. Electrical interlocks for sequential operation of up to 10 doors is available as well as pneumatic and explosion proof packages. This system is available in single slide widths ranging from 7 to 9 feet with a maximum slide opening of 3 to 4 feet and bi-parting widths ranging from 8 to 16 feet with a maximum slide opening of 3 to 7 feet. Click here to review the specifications and here to view the architectural details. Back to Table Of Contents Horton Automatics | Drive-Thru Service Windows 13 DOOR CONSTRUCTION Door panels are constructed from extruded aluminum. Horton doors feature a unique corner block design that adds rigidity to the panel and ensures years of trouble-free service in the most demanding conditions. The corner block design is a Horton exclusive and is far superior to lower grade through bolt construction typical of other manufacturers. Steel doors are typically provided for fire labeled applications. Stainless steel clad provides a superior non-corrosive finish. FINISHES Horton offers a number of industry standard anodic finishes including 204-R1 class II clear and 313-R1 class I dark bronze. Other finishes available include special anodize, powder or liquid paint. Cladding materials such as stainless steel and muntz metal (brass) are available in #4 brushed and #7 polished finishes. Anodize, powder paint and clad are free of Volatile Organic Compounds (VOCs). These are sound choices for GREEN design and LEED certification. Back to Table Of Contents Horton Automatics | Door Construction 14 QUALITY ASSURANCE AND CODE COMPLIANCE All Horton products are backed by a one year limited warranty against defect of materials and workmanship and a one year warranty by the installer for labor when installed by an authorized Horton Automatics distributor. If specifying a Horton Automatics door system in the United States or Canada, please verify your provider is certified by the American Association of Automatic Door Manufacturers (AAADM). Horton Automatics pedestrian doors comply with the following codes or standards: ANSI A156.10 Standard for Power Operated Pedestrian Doors encompasses automatic sliding, swinging and folding doors. A door installed by an authorized Horton Automatics distributor ensures professional and code-compliant installation. ANSI A156.19 Standard for Power Assist and Low Energy Power Operated Doors encompasses doors that operate at a slow speed with low power and can be remotely activated by a push switch/plate or another remote activation device. ANSI A156.27 Standard for Revolving Doors. ANSI A117.1 or ADA Compliance for accessibility. ADA and fire codes for means of egress. UL or ETL Listing, or equivalent as required. Wind load and impact testing as required for coastal applications. Consult a local Horton authorized service provider for verification of field compliance. INSTALLATION CONSIDERATIONS The floor should be level across the entire width of the automatic door opening. Minimally, the floor should be flat and level at least five feet in front of the breakout or swing area of the door(s). A slight slope away from the door (for drainage purposes) is acceptable and recommended. The rough opening should be approximately 1/2” larger than the overall door package width and 1/4” larger in height. Each automatic door requires an electrical supply on a separate 120 or 220V, 60 hertz, 15-amp circuit. DESIGN LIFE When properly used and maintained, your Horton Automatics system will last a lifetime. Your local distributor will advise of the typical maintenance schedule. Always demand the use of new genuine Horton Automatics parts when servicing your door system. Back to Table Of Contents Horton Automatics | Quality Assurance and Code Compliance 15