Circuit Protection
Transcription
Circuit Protection
Circuit Protection Series L8 Supplementary Protectors - General Description......................M2 Selection Guide - Trip Curve "B".............................................................M4 Selection Guide - Trip Curve "C".............................................................M6 Selection Guide - Trip Curve "D".............................................................M8 Accessories..........................................................................................M10 Technical Information............................................................................M12 Dimensions...........................................................................................M17 Series L9 Miniature Circuit Breakers - General Description....................M18 Selection Guide - Trip Curve "C"...........................................................M20 Selection Guide - Trip Curve "D"...........................................................M21 Accessories..........................................................................................M22 Technical Information............................................................................M24 Dimensions...........................................................................................M25 Methods Of Applying Circuit Protection.................................................M29 Applying L8 Supplementary Protectors with UL and NEC Guidelines......M31 Applying L9 Miniature Circuit Breakers with UL and NEC Guidelines......M32 Defining Electrical Standards................................................................M36 Series FH8 DIN-rail Mountable Fuse Holders.........................................M37 SSNA9000 Circuit Protection M M1 Series L8 Supplementary Protectors Sprecher+Schuh Series L8 Supplementary Protectors provide supplemental overcurrent protection for control circuits, solenoids, actuators, appliances, business equipment and a range of other applications where a high performance current limiting device is required. Advanced features and global approvals make them ideal for use in equipment installed throughout the world. Supplemental short circuit protection for a variety of applications Broad product range Series L8 Supplementary Protectors are available in up to 20 different current ratings from 0.5A to 63A, in one, two and three pole configurations. Over 180 base models are available with a full compliment of accessories. Devices can be used in applications up to 480V AC and 48V DC with interrupting capacities up to 10kA. ® Safety features provide enhanced protection The terminals of Series L8 Supplementary Protectors provide IP20 protection to guard against accidental contact with live parts. To aid troubleshooting, a color-coded indicator provides positive visual indication of the device status (green for OFF, red for ON) and isolation function. Sprecher+Schuh Supplementary Protectors also incorporate a trip-free mechanism - ensuring that the device operation cannot be defeated by holding the operator in the ON position. Easy installation Sprecher+Schuh Supplementary Protectors mount on a standard 35mm DIN-rail. Wire terminals accept multiple conductors, and bus bars can be used to quickly distribute power to many Supplementary Protectors simultaneously. In addition, power to the circuit breakers can be fed from the line or load side. Global approvals for worldwide acceptance Series L8 Supplementary Protectors are UL Recognized for use in the United States in accordance with NFPA 79 (NEC, National Electrical Code). The devices comply with UL 1077 and CSA 22.2 No.235, meeting the requirements for supplementary protectors intended for use as overcurrent protection where branch circuit protection is not required, or is provided by another device such as a fuse or molded case circuit breaker. These Supplementary Protectors also comply with IEC 60898 for use in commercial and residential applications and are CE marked. 17.5mm 35mm 52.5mm One Pole Two Pole Three Pole (≈11/16˝) M2 (≈1-3/8˝) (≈2-1/8˝) SSNA9000 L8 Circuit Protection M Three trip characteristics Sprecher+Schuh L8 Supplementary Protectors are also current limiting interrupting fault currents within one half cycle. Current limiting devices protect circuit components from damage by reducing the peak let-through current which causes damaging magnetic forces and let-through energy which generates heat. Compare these advanced features Box lug terminals accept #18…#4 (1.0…25mm2) wire as standard 120 t [min] 60 20 10 5 2 1 Type “C” Characteristic Developed primarily for applications with moderate inrush currents such as lighting, control circuits and coils, computers and appliances. Instantaneous trip is five to ten times the rated current of the Supplementary Protector (5~10 x In). The higher instantaneous trip level prevents nuisance tripping, and components being protected can typically withstand higher fault currents without being damaged. 30 10 5 2 1 0.5 t [sec] All Sprecher+Schuh L8 Supplementary Protectors are available with three different tripping characteristics, Type “B”, “C”, and “D”. The tripping characteristic defines the device’s speed of response (trip-time) to various levels of overcurrent. Figure 1 shows trip-time versus overcurrent for Type B, C, and D devices. The time-current characteristics enable the device to be optimally matched to the application. For example, PLC outputs that can only tolerate minimal overcurrents are best protected by Supplementary Protectors with Type B trip characteristics. Type “B” Characteristic Developed primarily to protect conductors and low level signal devices such as PLCs. Instantaneous trip is three to five times the rated current of the Supplementary Protector (3~5 x In). The fast trip time of these devices minimizes damage to control circuit conductors from low-level faults. (Curves at 30º C) 0.2 0.1 0.05 0.02 0.01 0.005 0.002 0.001 0.0005 1 2 3 4 5 6 7 8 9 10 15 20 I / IN Figure 1 Sprecher+Schuh Series L8 Supplementary Protector Trip Characteristics 30 40 50 Type “D” Characteristic Developed primarily for applications with high inrush currents, i.e., transformers, power supplies and heaters. Instantaneous trip is ten to twenty times the rated current of the Supplementary Protector (10~20 x In). The high instantaneous trip level prevents nuisance tripping, and components being protected can typically withstand higher fault currents without being damaged. Line and load side terminals accept bus bar connections for reduced costs and more efficient installation of multiple devices. Guarded pozidrive terminal screws with finger-safe protection to IEC 947-1 Ratings to 480Y/277V AC @ 240/415V AC - 10kA Interrupt Rating Magnetic trip elements provide Type B, C and D trip characteristics (IEC and EN 60898), while bimetallic elements protect against slight overloads. Available in one, two and three pole; one pole + neutral and three pole + neutral M L8 SSNA9000 Amp rating and trip curve characteristic clearly marked on the device for easy identification Color coded indicator provides visual indication of the device status and isolation function Circuit Protection Devices install on standard 35mm DIN-rail (EN 50022) Trip-free mechanism; device operation cannot be defeated by holding the operator in the ON position M3 L8 Supplementary Protectors Trip Characteristic B Trip Characteristic B (3~5 x IN) – Resistive or slightly inductive loads ➌ 2 Pole ➋ 1 Pole ➊ Rated Current (A) Catalog Number Price Std. Pkg. Catalog Number 3 Pole ➋ Price Std. Pkg. Catalog Number Price Std. Pkg. 1 L8-1/1/B 38 12 L8-1/2/B 82 6 L8-1/3/B 124 4 2 L8-2/1/B 38 12 L8-2/2/B 82 6 L8-2/3/B 124 4 3 L8-3/1/B 38 12 L8-3/2/B 82 6 L8-3/3/B 124 4 4 L8-4/1/B 38 12 L8-4/2/B 82 6 L8-4/3/B 124 4 5 L8-5/1/B 38 12 L8-5/2/B 82 6 L8-5/3/B 124 4 6 L8-6/1/B 38 12 L8-6/2/B 82 6 L8-6/3/B 124 4 7 L8-7/1/B 38 12 L8-7/2/B 82 6 L8-7/3/B 124 4 8 L8-8/1/B 38 12 L8-8/2/B 82 6 L8-8/3/B 124 4 10 L8-10/1/B 38 12 L8-10/2/B 82 6 L8-10/3/B 124 4 13 L8-13/1/B 38 12 L8-13/2/B 82 6 L8-13/3/B 124 4 15 L8-15/1/B 38 12 L8-15/2/B 82 6 L8-15/3/B 124 4 16 L8-16/1/B 38 12 L8-16/2/B 82 6 L8-16/3/B 124 4 20 L8-20/1/B 40 12 L8-20/2/B 90 6 L8-20/3/B 137 4 25 L8-25/1/B 40 12 L8-25/2/B 90 6 L8-25/3/B 137 4 30 L8-30/1/B 40 12 L8-30/2/B 90 6 L8-30/3/B 137 4 32 L8-32/1/B 42 12 L8-32/2/B 99 6 L8-32/3/B 149 4 40 L8-40/1/B 44 12 L8-40/2/B 103 6 L8-40/3/B 155 4 50 L8-50/1/B 50 12 L8-50/2/B 118 6 L8-50/3/B 179 4 63 L8-63/1/B 59 12 L8-63/2/B 134 6 L8-63/3/B 204 4 L8 Supplementary Protector Features: •UL-1077 Approved, CSA 22.2 No. 235 and IEC/EN 60898 •Thermal Magnetic Overcurrent Protection •Trip characteristics based on 40ºC ambient for UL/CSA •Up to 10kA interruption ratings •Finger safe design •DIN-rail mounting SSNA9000 L8 Circuit Protection M ➊ 1-Pole ratings: UL/CSA 277VAC 48VDC, IEC 240/415VAC ➋ Multi-pole ratings: UL/CSA 480Y/277VAC 125VDC, IEC 415VAC ➌ See UL Short Circuit ratings U1/U2 in the technical data sections. M4 Discount Schedule B-8 L8 Supplementary Protectors Trip Characteristic B Trip Characteristic B (3~5 x IN) – Resistive or slightly inductive loads 1 Pole + Neutral Rated Current (A) Catalog Number 3 Pole + Neutral Std. Price Pkg. Catalog Number Std. Price Pkg. 1 L8-1/1N-2/B 65 6 L8-1/3N/B 149 3 2 L8-2/1N-2/B 65 6 L8-2/3N/B 149 3 4 L8-4/1N-2/B 65 6 L8-4/3N/B 149 3 6 L8-6/1N-2/B 65 6 L8-6/3N/B 149 3 8 L8-8/1N-2/B 65 6 L8-8/3N/B 149 3 10 L8-10/1N-2/B 65 6 L8-10/3N/B 149 3 13 L8-13/1N-2/B 65 6 L8-13/3N/B 149 3 16 L8-16/1N-2/B 65 6 L8-16/3N/B 149 3 20 L8-20/1N-2/B 78 6 L8-20/3N/B 174 3 25 L8-25/1N-2/B 78 6 L8-25/3N/B 174 3 32 L8-32/1N-2/B 78 6 L8-32/3N/B 174 3 40 L8-40/1N-2/B 78 6 L8-40/3N/B 174 3 50 L8-50/1N-2/B 99 8 L8-50/3N/B 227 3 63 L8-63/1N-2/B 107 8 L8-63/3N/B 252 3 All Supplementary Protectors + neutral are special order. L8 SSNA9000 Circuit Protection M Discount Schedule B-8 M5 L8 Supplementary Protectors Trip Characteristic C Trip Characteristic C (5~10 x IN) – Inductive loads ➌ 2 Pole ➋ 1 Pole ➊ Rated Current (A) Catalog Number 0.5 L8-.5/1/C Std. Price Pkg. Catalog Number 44 12 L8-.5/2/C 3 Pole ➋ Std. Price Pkg. Catalog Number 101 6 L8-.5/3/C Std. Price Pkg. 145 4 1 L8-1/1/C 44 12 L8-1/2/C 101 6 L8-1/3/C 145 4 2 L8-2/1/C 44 12 L8-2/2/C 101 6 L8-2/3/C 145 4 3 L8-3/1/C 44 12 L8-3/2/C 101 6 L8-3/3/C 145 4 4 L8-4/1/C 44 12 L8-4/2/C 101 6 L8-4/3/C 145 4 5 L8-5/1/C 44 12 L8-5/2/C 101 6 L8-5/3/C 145 4 6 L8-6/1/C 44 12 L8-6/2/C 101 6 L8-6/3/C 145 4 7 L8-7/1/C 44 12 L8-7/2/C 101 6 L8-7/3/C 145 4 8 L8-8/1/C 44 12 L8-8/2/C 101 6 L8-8/3/C 145 4 10 L8-10/1/C 44 12 L8-10/2/C 101 6 L8-10/3/C 145 4 13 L8-13/1/C 44 12 L8-13/2/C 101 6 L8-13/3/C 145 4 15 L8-15/1/C 44 12 L8-15/2/C 101 6 L8-15/3/C 145 4 16 L8-16/1/C 44 12 L8-16/2/C 101 6 L8-16/3/C 145 4 20 L8-20/1/C 44 12 L8-20/2/C 101 6 L8-20/3/C 145 4 25 L8-25/1/C 48 12 L8-25/2/C 111 6 L8-25/3/C 164 4 30 L8-30/1/C 48 12 L8-30/2/C 111 6 L8-30/3/C 164 4 32 L8-32/1/C 50 12 L8-32/2/C 111 6 L8-32/3/C 166 4 40 L8-40/1/C 55 12 L8-40/2/C 122 6 L8-40/3/C 183 4 50 L8-50/1/C 63 12 L8-50/2/C 143 6 L8-50/3/C 210 4 63 L8-63/1/C 71 12 L8-63/2/C 160 6 L8-63/3/C 239 4 L8 Supplementary Protector Features: •UL-1077 Approved, CSA 22.2 No. 235 and IEC/EN 60898 •Thermal Magnetic Overcurrent Protection •Trip characteristics based on 40ºC ambient for UL/CSA •Up to 10kA interruption ratings •Finger safe design •DIN-rail mounting SSNA9000 L8 Circuit Protection M ➊ 1-Pole ratings: UL/CSA 277VAC 48VDC, IEC 240/415VAC ➋ Multi-pole ratings: UL/CSA 480Y/277VAC 125VDC, IEC 415VAC ➌ See UL Short Circuit ratings U1/U2 in the technical data sections. M6 Discount Schedule B-8 L8 Supplementary Protectors Trip Characteristic C Trip Characteristic C (5~10 x IN) – Inductive loads 1 Pole + Neutral Rated Current (A) Catalog Number 3 Pole + Neutral Std. Price Pkg. Catalog Number Std. Price Pkg. 1 L8-1/1N-2/C 88 6 L8-1/3N/C 210 3 2 L8-2/1N-2/C 88 6 L8-2/3N/C 210 3 4 L8-4/1N-2/C 88 6 L8-4/3N/C 210 3 5 L8-5/1N-2/C 88 6 Not Available ~ ~ 6 L8-6/1N-2/C 88 6 L8-6/3N/C 210 3 8 L8-8/1N-2/C 88 6 L8-8/3N/C 210 3 10 L8-10/1N-2/C 88 6 L8-10/3N/C 210 3 13 L8-13/1N-2/C 88 6 L8-13/3N/C 210 3 16 L8-16/1N-2/C 88 6 L8-16/3N/C 210 3 20 L8-20/1N-2/C 88 6 L8-20/3N/C 210 3 25 L8-25/1N-2/C 95 6 L8-25/3N/C 221 3 32 L8-32/1N-2/C 97 6 L8-32/3N/C 223 3 40 L8-40/1N-2/C 101 6 L8-40/3N/C 239 3 50 L8-50/1N-2/C 128 8 L8-50/3N/C 290 3 63 L8-63/1N-2/C 137 8 L8-63/3N/C 319 3 All Supplementary Protectors + neutral are special order. L8 SSNA9000 Circuit Protection M Discount Schedule B-8 M7 L8 Supplementary Protectors Trip Characteristic D Trip Characteristic D (10~20 x IN) – Highly inductive loads ➌ 2 Pole ➋ 1 Pole ➊ Rated Current (A) Catalog Number Std. Price Pkg. Catalog Number 3 Pole ➋ Std. Price Pkg. Catalog Number Std. Price Pkg. 0.5 L8-.5/1/D 44 12 L8-.5/2/D 101 6 Not Available ~ ~ 1 L8-1/1/D 44 12 L8-1/2/D 101 6 L8-1/3/D 145 4 2 L8-2/1/D 44 12 L8-2/2/D 101 6 L8-2/3/D 145 4 3 L8-3/1/D 44 12 L8-3/2/D 101 6 L8-3/3/D 145 4 4 L8-4/1/D 44 12 L8-4/2/D 101 6 L8-4/3/D 145 4 5 L8-5/1/D 44 12 L8-5/2/D 101 6 L8-5/3/D 145 4 6 L8-6/1/D 44 12 L8-6/2/D 101 6 L8-6/3/D 145 4 7 L8-7/1/D 44 12 L8-7/2/D 101 6 L8-7/3/D 145 4 8 L8-8/1/D 44 12 L8-8/2/D 101 6 L8-8/3/D 145 4 10 L8-10/1/D 44 12 L8-10/2/D 101 6 L8-10/3/D 145 4 13 L8-13/1/D 44 12 L8-13/2/D 101 6 L8-13/3/D 145 4 15 L8-15/1/D 44 12 L8-15/2/D 101 6 L8-15/3/D 145 4 16 L8-16/1/D 44 12 L8-16/2/D 101 6 L8-16/3/D 145 4 20 L8-20/1/D 44 12 L8-20/2/D 101 6 L8-20/3/D 145 4 25 L8-25/1/D 48 12 L8-25/2/D 111 6 L8-25/3/D 164 4 30 L8-30/1/D 48 12 L8-30/2/D 111 6 L8-30/3/D 164 4 32 L8-32/1/D 50 12 L8-32/2/D 111 6 L8-32/3/D 166 4 40 L8-40/1/D 55 12 L8-40/2/D L8-40/3/D 183 4 122 6 L8 Supplementary Protector Features: •UL-1077 Approved, CSA 22.2 No. 235 and IEC/EN 60898 •Thermal Magnetic Overcurrent Protection •Trip characteristics based on 40ºC ambient for UL/CSA •Up to 10kA interruption ratings •Finger safe design •DIN-rail mounting SSNA9000 L8 Circuit Protection M ➊ 1-Pole ratings: UL/CSA 277VAC 48VDC, IEC 240/415VAC ➋ Multi-pole ratings: UL/CSA 480Y/277VAC 125VDC, IEC 415VAC ➌ See UL Short Circuit ratings U1/U2 in the technical data sections. M8 Discount Schedule B-8 L8 Supplementary Protectors Trip Characteristic D Trip Characteristic D (10~20 x IN) – Highly inductive loads 1 Pole + Neutral Rated Current (A) Catalog Number 3 Pole + Neutral Std. Price Pkg. Catalog Number Price Std. Pkg. 1 L8-1/1N-2/D 88 6 L8-1/3N/D 210 3 2 L8-2/1N-2/D 88 6 L8-2/3N/D 210 3 4 L8-4/1N-2/D 88 6 L8-4/3N/D 210 3 6 L8-6/1N-2/D 88 6 L8-6/3N/D 210 3 8 L8-8/1N-2/D 88 6 L8-8/3N/D 210 3 10 L8-10/1N-2/D 88 6 L8-10/3N/D 210 3 13 L8-13/1N-2/D 88 6 L8-13/3N/D 210 3 16 L8-16/1N-2/D 88 6 L8-16/3N/D 210 3 20 L8-20/1N-2/D 88 6 L8-20/3N/D 210 3 25 L8-25/1N-2/D 95 6 L8-25/3N/D 221 3 32 L8-32/1N-2/D 97 6 L8-32/3N/D 223 3 40 L8-40/1N-2/D 101 6 L8-40/3N/D 239 3 All Supplementary Protectors + neutral are special order. L8 SSNA9000 Circuit Protection M Discount Schedule B-8 M9 Accessories Series L8 Supplementary Protectors Accessories Module For use with… Description Connection Diagrams Catalog Number Price Selectable Two Pole Auxiliary Contact or Auxiliary / Signal Alarm Module – • Small set-screw alternates between operational modes • Two Form C (two changeover contacts) •Installs on left side of L8 • Auxiliary contact switches when L8 is operated manually or tripped electrically • Signal Alarm contact switches only when L8 is tripped electrically All L8s & Shunt Trip Two pole auxiliary mode LX-AHS3 71 12…110VAC (12…60VDC) Z8-ASA24 145 110…415VAC (110…230VDC) Z8-ASA230 145 Z8-USA115 Z8-USA230 307 Auxiliary / Signal alarm mode All L8s Shunt Trip – • Remotely trips the device • Installs on left side of L8 Undervoltage Release – • Prevents device from operating unless voltage is present • Installs on left side of L8 • Test button All L8s 50…115 VAC 110…230 VAC Allowable Combinations of Field Installed Modules M L8 All modules install on the left side of the L8. M10 Discount Schedule B-8 SSNA9000 Circuit Protection (1) Auxiliary Contact Module (1) Selectable Two Pole Auxiliary Contact Module / Auxiliary & Signal Alarm Contact Module (1) Shunt Trip Module (1) Undervoltage Release Module (1) Auxiliary Contact Module + (1) Shunt Trip Module Accessories Series L8 Supplementary Protectors Accessories Accessory Description For use with… Bus Bar – ➊ • Connects one, two and three pole L8s • Connects one pole + neutral and three pole + neutral MCBs • Rated to 80A • Available in 1 meter lengths • IEC rated only End Caps – ➋ • Covers end of Bus Bar to provide touch safe protection (minimum order quantity 10) Padlock Hasp – • Fits securely over switch handle. Prevents unauthorized activation of L8 during maintenance • Provision for one padlock Catalog Number Price All L8 one pole devices ZV7-16-1P-1TE 54 All L8 two pole devices & one pole + neutral ZV7-16-1P+N-2TE 147 All L8 three pole devices ZV7-16-3P-3TE 185 All L8 three pole + neutral devices ZV7-16-3P+N-4TE 250 Fits ZV7-16-1P+N-2TE & ZV7-16-3P-3TE ZV7-16-AK/2+3P 3 Fits ZV7-16-3P+N-4TE ZV7-16-AK/4P 3 All L8 MCBs L8-ASPLOA 12 DIN-rail - 2 meter lengths (6' 6") 3F 3AF Top Hat, low profile (price per rail) Top Hat, high profile (price per rail) See page A58 Circuit Protection ➊ Each bus bar accommodates: 1 pole bus connects 57 devices 2 pole bus connects 28 devices 3 pole bus connects 19 devices Total current must not exceed 80A per bus. ➋ Sold in packages of 10. Price indicated is price per piece. Minimum order quantity 10. L8 SSNA9000 M Discount Schedule B-8 M11 Technical Information Series L8 Supplementary Protectors Technical Information General Data B Curve C Curve D Curve Resistive or slightly resistive Inductive Loads Highly Inductive Loads Tripping Characteristic In Approvals 3…5 x In UR, CSA, CE 5…10 x In UR, CSA, CE (All models ) IEC-EN 60 898 / DIN 43 880 10…20 x In UR, CSA, CE Supplementary Protector Approvals UL 1077 - Recognized Component QVNU2 - E304759 CSA 22.2 No. 235 Certified Component UG A - General Industrial FW 3 Line and Load evaluated for field wiring OL 0 (general use) Use Group (UG) Terminals (FW) Overload Rating (OL) 1-Pole, 1-Pole + N Maximum Volts Tripping Current (TC) Short-Circuit Current Rating (SC) < 35 A 40, 50, 63 A 277V AC TC 1, 40 °C SC U2 10 kA @ 277V AC; B and C Curve 5 kA @ 277V AC; D Curve 5 kA @ 277V AC; B, C, and D Curve 48V DC TC 1, 40 °C SC U1 10 kA @ 48V DC; B, C, and D Curve 480Y/277V AC TC 2, 40 °C 125V DC (2-pole - series) TC 2, 40 °C 10 kA @ 48V DC; B, C, and D Curve 2-Pole, 3-Pole, 3-Pole + N Maximum Volts Tripping Current SC U2 SC U1 10 kA @ 125V DC; B, C, and D Curve 40, 50, 63 A 10 kA @ 480Y/277V AC; B and C Curve 5 kA @ 480Y/277V AC; D Curve 5 kA @ 480Y/277V AC; B, C, and D Curve [A] IEC / EN 60 898 IEC / EN 60 947-2 1…63 Short-Circuit Current Rating (SC) < 35 A 10 kA @ 125V DC; B, C, and D Curve Miniature Circuit Breaker Approvals Current Range Thermal Tripping Characteristic Interrupt Rating; 1 pole Interrupt Rating; multi-pole Rated Impulse Withstand Voltage U Rated Insulation Voltage U Overload Category / Pollution Degree Rated Operation Voltage U Approval Rated Ultimate Short Circuit Breaking Capacity [kA] [kA] [V] [VAC] 0.5…63 >1 hr. at 1.13 x In <1 hr. at 1.45 x In 0.5…40 10 @ 240VAC 10 @ 415VAC 4000V 440VAC III / 2 240 / 415 IEC / EN 60 947-2 [VAC] 15 – 0.5 cos @240 / 415VAC L8 SSNA9000 Circuit Protection M M12 Discount Schedule B-8 Technical Information Series L8 Supplementary Protectors Technical Information (continued) Environmental and General Specifications Dielectric Strength Shock Vibration [VAC] [G] Operating Temperature Range Shipment and Short Term Temperature Limits Housing Material Switched Neutral Rating [°F] 1960 25 (half sine wave for 11ms - 3 axis) Frequency range: 10…2000Hz Maximum amplitude (p - p) = 0.030 in. Maximum acceleration = 5G 2 hours each of 3 axis 23…+104 (–5…+40°C) [°F] –40…+185 (–40…+85°C) Nylon 277 6000 operations (1 operation = 2 switching events) ON/OFF [VAC] Electromechanical Life Circuit Diagrams 1 pole 1 pole + neutral 2 pole Back up Protection Supplementary Protectors / Fuses: The following table shows the maximum short circuit current when fuses meeting the requirements of IEC 60269-1 are used as backup protection to MCBs. 3 pole 3 pole + neutral Miniature Circuit Breaker Characteristic B Characteristic C Upstream Fuse 160A 200A Rated Current (In) 100A 1…10A 40kA 25kA 25kA 10…50A 50kA 40kA 25kA 63A 50kA 40kA 10kA Mechanical Data Degree of Protection Mechanical endurance Method of mounting Supply connection Terminations Wire size [ops.] solid / stranded Recommended Wire Strip Length Weight / pole Mounting Position in (mm) [g] / [lb] 360˚ IP20 6,000 (1 operation = 2 switching movements – ON/OFF 35mm mounting rail (EN50022) Line or load side #18…4 AWG (1.0…10 mm2) Tightening Torque — 2.4 N•m (21 lb-in.) #6…4 AWG (1.6…25 mm2) Tightening Torque — 3.1 N•m (27 lb-in.) 0.51 (13) 120 / 0.32 360˚ L8 SSNA9000 Circuit Protection M Discount Schedule B-8 M13 Technical Information Series L8 Supplementary Protectors Technical Information (continued) Continuous Current Rating Factor Rated Diversity Factor When multiple supplementary protectors are mounted side by side, they must be derated to determine the load carrying capacity. Accessories Degree of protection (Field Wiring Terminals) Minimum Impulse Duration Minimum Command Time Operating Voltage [ms] [ms] [V] Auxiliaries Z8-AHK, NHK IP20 (IP 00) ~ ~ ~ ~ Inrush Current ~ [V] ~ ~ Dropout Voltage Range Max. operational current Ie AC13 IEC AC15 DC12 250V [A] 250V [A] 110V [A] UL1077 / CSA22.2 230V [A] 110V [A] AC DC Mechanical Life-span Terminations ➊ [ops] 0.7…0.35 x Us ~ ~ ~ ~ ~ Shunt Trip Z8-ASA… IP20 (IP 00) >15 ≤200 12…110VAC (Z7-ASA24) 12…60VDC 110…415VAC (Z7-ASA230) 110…230VDC 25 / 12 (AC 15 / 2 (DC) ~ 0.7…1.1 x Us ~ ~ ~ ~ 3 0.5 0.5 Umin - 5V CDC 2 0.5 Umin - 5V CDC Auxiliaries Z8-AHK, NHK 6000 ~ ~ ~ ~ Undervoltage Release Z8-USA… 10000 Shunt Trip Z8-ASA… 4000 0.5…2.5 (18…14) 0.5…2.5 (18…14) 0.8 / 7 45 / 0.1 0.5…4 (18…14) 0.5…2.5 (18…14) 1.1 / 10 155 / 0.4 1.0…25 (18…8) 1.0…4 (18…12) 2.4 / 21 155 / 0.4 Terminal type Wire size solid / stranded Tightening torque Weight 1 conductor 2 conductors [Nm] / [lb-in] [g] / [lbs] ➊ When using two wires, use same cross section. M14 Discount Schedule B-8 SSNA9000 L8 Circuit Protection M [mA] Undervoltage Release Z8-USA… IP20 (IP 00) ~ ~ Un - 115V (Z7-USA115) Umin - 50V Un - 230/240 (Z7-USA230) Umin - 110V 3.6 / 44 (AC/DC) Technical Information Series L8 Supplementary Protectors Technical Information (continued) Maximum let-through energy L8 Maximum let-through current L8 Type B Type B 3 B60 B5 0 4 B 2 B35 B2 0 B26 B1 3 B1 0 B1 50000 40000 30000 10000 9000 8000 7000 6000 6 B1 3 B1 0 B1 5000 4000 20000 B6 B4 10000 9000 8000 7000 6000 5000 B2 4000 3000 B6 B4 3000 Let-through current [A] 15000 Let-through energy I2t [A2 sec] B2 B2 B3 B4 B B6 0 5 2 0 50 3 80000 70000 60000 2000 1500 B2 1000 2000 1500 1000 900 800 700 600 500 500 400 Available short circuit current [A] Maximum let-through energy L8 Maximum let-through current L8 15000 6000 7000 8000 9000 10000 4000 3000 2000 1500 Available short-circuit current [A] Type C Type C 3 C6 0 C5 0 C42 C3 5 C20 C26 C1 3 C10 C1 80000 70000 60000 50000 40000 30000 10000 9000 8000 C630 C5 C402 C3 5 C2 C206 C1 C130 C1 7000 6000 5000 C6 C4.5 C3 C3 4000 20000 C6 C4 C3.5 10000 9000 8000 7000 6000 5000 C3 C2.5 C2 C1.5 4000 3000 3000 Let-through current [A] 15000 Let-through energy I2t [A2 sec] 1000 500 15000 7000 8000 9000 10000 6000 4000 5000 3000 2000 1500 1000 500 300 2000 5 C2. C2 5 C1. 1500 1000 2000 C1 1500 C1 1000 900 800 700 600 500 C0.5 400 6000 7000 8000 9000 10000 4000 3000 2000 1500 15000 L8 Available short-circuit current [A] 1000 500 15000 7000 8000 9000 10000 6000 4000 5000 3000 2000 1500 1000 500 300 SSNA9000 M Circuit Protection 500 Available short circuit current [A] Discount Schedule B-8 M15 Technical Information Series L8 Supplementary Protectors Technical Information (continued) Maximum let-through current L8 Maximum let-through energy L8 Type D Type D 10000 9000 8000 0 D42 D35 2 D0 D2 6 D13 D1 0 1 D 80000 70000 60000 50000 40000 30000 6000 5000 D6 4000 20000 D4 D2 D4 15000 3000 D2 10000 9000 8000 7000 6000 5000 Let-through current [A] Let-through energy I2t [A2 sec] 0 D42 D3 5 D20 2 D 6 D1 3 D10 D1 D6 7000 4000 3000 2000 1500 1000 2000 1500 1000 900 800 700 600 500 500 400 Available short-circuit current [A] 15000 6000 7000 8000 9000 10000 4000 3000 2000 1500 1000 500 15000 7000 8000 9000 10000 6000 4000 5000 3000 2000 1500 1000 500 300 Available short circuit current [A] L8 SSNA9000 Circuit Protection M M16 Discount Schedule B-8 Dimensions Series L8 Supplementary Protectors L8 Supplementary Protectors (Series L8…B, C & D) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 1-pole 2-pole and 1-pole + neutral 3-pole 3-pole + neutral One & Two Pole Auxiliary Contact, Signal Alarm Contact (LX-AHS3) Shunt Trip & Undervoltage Release Modules (Z8-ASA…& Z8-USA…) Undervoltage Release Module L8 SSNA9000 Shunt Trip Circuit Protection M Discount Schedule B-8 M17 Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada and certified as a Miniature Circuit Breaker for IEC applications. Series L9 UL-489 Miniature Circuit Breakers Broad product range & flexibility Industrial Circuit Breakers for Branch Circuit Protection up to 40 Amps The Sprecher + Schuh L9 Miniature Circuit Breakers provide a variety of product configurations by offering current ranges of 0.5A to 40A with voltage ranges of 240V AC and 480Y/277V AC. The Series L9 DIN Rail-mounted circuit breakers are similar in width and current range to circuit breakers with the added benefit of providing listed branch circuit protection circuit breaker for US/Canada applications. ® Also available for control circuit applications are add-on auxiliary and signal contacts plus shunt trip modules to provide modern control circuit applications. A lock-off attachment is available for applications requiring that feature. Safety features provide enhanced protection The series L9 Miniature Circuit Breakers feature finger-safe IPX/2 from the front of the circuit breaker to guard against accidental contact with live parts. To aid troubleshooting, a color-coded indicator provides positive visual indication of the device status (green for OFF, red for ON and isolation function). The Series L9 also incorporate a trip free mechanism - ensuring that the device operation cannot be defeated by holding the operator in the ON position. Easy installation The Series L9 Miniature Circuit Breakers mount on a standard 35mm DINrail. Wire terminals accept multiple conductors. In addition, power to the circuit breakers can be fed from the line or load side. Global approvals for worldwide acceptance The Sprecher + Schuh L9 Circuit Breakers are UL489 listed, CSA 22.2 No. 5.1 approved and meets IEC 60 947-2. The Series L9 also have an HACR rating (heating and air conditioning) as well as a "Switching Duty" (SWD) rating from 0.5 to 20A. Switching Duty ratings are related to fluorescent light applications only, not High intensity discharge (HID) lights or any other types of loads. Advanced features and global approvals make the Series L9 an ideal product for use in industrial equipment installed throughout the world. 17.5mm 35mm 52.5mm One Pole Two Pole Three Pole (≈11/16˝) M18 (≈1-3/8˝) (≈2-1/8˝) SSNA9000 L9 Circuit Protection M The Series L9 products are thermalmagnetic (inverse time) circuit breakers offering the benefits of a modern circuit breaker design in a compact size. The L9 is used mainly in control circuit applications where branch circuit approved circuit breakers are required. Because of its range of protection (from 0.5 to 40A) many customers may use this product for protection of load devices where fuses or other supplementary protector devices previously were used in the U.S. and Canada. North American applications (UL 489 and CSA 22.2 No. 5.1). For IEC applications, the products are rated 415V AC 0.5 to 40A. Continuous Current Rating Standard current ratings are: 0.5A, 1A, 1.5A, 2A, 3A, 4A, 5A, 6A, 7A, 8A, 10A, 15A, 16A, 20A, 25A, 30A, 32A, 35A and 40A. Description The L9 circuit breakers are rated in RMS amperes at 40°C (104°F) ambient temperature per the UL 489 (CSA 22.2 No. 5.1) standard. This temperature is generally used as the average temperature within an industrial enclosure. If a circuit breaker is applied in a temperature that exceeds 40°C (104°F) ambient, then the circuit breaker should be derated. For IEC 60 947-2 standard, the products carry an ambient rating of 30° C. Follow standard IEC application considerations for temperature rating in different ambient temperatures. L9 Circuit Breakers for Branch Circuit protection are available one (1)-, two (2-), and three (3-) pole construction and are rated 0.5 to 40A at 240VC AC and 0.5 to 20A at 480Y/277V AC for The characteristic trip curves are shown on page M34. The trip bands shown for each breaker represent current tripping limits for a circuit Protection of PLC I/O, solenoids, power supplies and control transformers along with providing the listed branch circuit protection is available in one device. Compare these advanced features Box lug terminals accept #18…#6 AWG wire as standard Current limiting and interrupting capacity up to 10kA at 480Y/277V AC. Trip-free mechanism; device operation cannot be defeated by holding the operator in the ON position Color coded indicator provides visual indication of the device status and isolation function Example: The L9 time-current graph on page M34 shows that a one-pole, 15 A, L9 circuit breaker trips in not less than 10 sec, and not more than 120 sec. on a 30 A current. Because the UL standard defines this time spread, users should not specify exact tripping time. The lower current portion of the curves (upper left) depict the time to trip due to thermal action and reflect overload protection of the wire and connect load. The higher current portion of the curves (lower right) depicts the trip due to the magnetic action of the circuit breaker and reflects protection due to short circuit level currents. Line and load side terminals accept bus bar connections for reduced costs and more efficient installation of multiple devices. Guarded pozidrive terminal screws with finger-safe protection to IEC 947-1 Devices install on standard 35mm DIN-rail (EN 50022) Magnetic trip elements provide Type C and D trip characteristics (IEC and EN 60898), while bimetallic elements protect against slight overloads. M Amp rating and trip curve characteristic clearly marked on the device for easy identification. L9 SSNA9000 Available in one, two and three pole; breaker and are within the limits established by UL. For a specific current at 40°C (104°F), a circuit breaker will open ("clear the circuit") automatically at some total time that will be within the "Minimum" and "Maximum" time shown on the curves. Circuit Protection Product Design & Application M19 L9 UL489 Miniature Circuit Breakers Trip Characteristic C Trip Characteristic C (5~10 x IN) – Inductive loads 1 Pole ➋ ➊ UL/CSA Rated Max. Current Volt. (A) Catalog Number 0.5 1 1.5 480Y/277 240 Price Std. Pkg. Catalog Number Price Std. Pkg. Catalog Number Price Std. Pkg. L9-.5/1/C 97 2 L9-.5/2/C 185 1 L9-.5/3/C 251 1 L9-1/1/C 97 2 L9-1/2/C 185 1 L9-1/3/C 251 1 L9-1.5/1/C 97 2 L9-1.5/2/C 185 1 L9-1.5/3/C 251 1 2 L9-2/1/C 97 2 L9-2/2/C 185 1 L9-2/3/C 251 1 3 L9-3/1/C 97 2 L9-3/2/C 185 1 L9-3/3/C 251 1 4 L9-4/1/C 97 2 L9-4/2/C 185 1 L9-4/3/C 251 1 5 L9-5/1/C 97 2 L9-5/2/C 185 1 L9-5/3/C 251 1 6 L9-6/1/C 97 2 L9-6/2/C 185 1 L9-6/3/C 251 1 7 L9-7/1/C 97 2 L9-7/2/C 185 1 L9-7/3/C 251 1 8 L9-8/1/C 97 2 L9-8/2/C 185 1 L9-8/3/C 251 1 10 L9-10/1/C 97 2 L9-10/2/C 185 1 L9-10/3/C 251 1 13 L9-13/1/C 97 2 L9-13/2/C 185 1 L9-13/3/C 251 1 15 L9-15/1/C 97 2 L9-15/2/C 185 1 L9-15/3/C 251 1 16 L9-16/1/C 97 2 L9-16/2/C 185 1 L9-16/3/C 251 1 20 L9-20/1/C 97 2 L9-20/2/C 185 1 L9-20/3/C 251 1 25 L9-25/1/C 107 2 L9-25/2/C 198 1 L9-25/3/C 251 1 30 L9-30/1/C 110 2 L9-30/2/C 211 1 L9-30/3/C 279 1 32 L9-32/1/C 110 2 L9-32/2/C 211 1 L9-32/3/C 279 1 35 L9-35/1/C 110 2 L9-35/2/C 211 1 L9-35/3/C 279 1 40 L9-40/1/C 115 2 L9-40/2/C 227 1 L9-40/3/C 292 1 L9 Miniature Circuit Breaker Features: • UL-489 listed for Branch Circuit protection and CSA 22.2 No. 5.1 Approved • Thermal magnetic protection • Trip characteristic based on 40°C ambient for UL/CSA • 10kA interrupting rating • All ratings are HACR rated (SWD rated up to 20 A) • Finger safe design (front) • DIN rail mounting ➊ Rated 415V AC, 48V DC, IEC max/min meets IEC 60947-2 for miniature circuit breakers. ➋ 1-Pole 277V AC, 48V DC 0.5…20A; 240V AC, 48V DC 30…40A ➌ 2-Pole (series) 96VDC 0.5...40A M20 Discount Schedule B-8 SSNA9000 L9 Circuit Protection M 3 Pole 2 Pole ➌ L9 UL489 Miniature Circuit Breakers Trip Characteristic D Trip Characteristic D (10~20 x IN) – Highly inductive loads 1 Pole ➋ ➊ UL/CSA Rated Max. Current Volt. (A) Catalog Number 0.5 240 Price 3 Pole Std. Pkg. Catalog Number Price Std. Pkg. Catalog Number Price Std. Pkg. L9-.5/1/D 97 2 L9-.5/2/D 186 1 L9-1.5/3/D 256 1 1 L9-1/1/D 97 2 L9-1/2/D 186 1 L9-1/3/D 256 L9-1.5/1/D 97 2 L9-1.5/2/D 186 1 L9-1.5/3/D 256 1 2 L9-2/1/D 97 2 L9-2/2/D 186 1 L9-2/3/D 256 1 3 L9-3/1/D 97 2 L9-3/2/D 186 1 L9-3/3/D 256 1 4 L9-4/1/D 97 2 L9-4/2/D 186 1 L9-4/3/D 256 1 186 1 L9-5/3/D 256 1 1 1 1.5 480Y/277 2 Pole ➌ 5 L9-5/1/D 97 2 L9-5/2/D 6 L9-6/1/D 97 2 L9-6/2/D 186 1 L9-6/3/D 256 7 L9-7/1/D 97 2 L9-7/2/D 186 1 L9-7/3/D 256 1 186 1 L9-8/3/D 256 1 1 8 L9-8/1/D 97 2 L9-8/2/D 10 L9-10/1/D 97 2 L9-10/2/D 186 1 L9-10/3/D 256 13 L9-13/1/D 97 2 L9-13/2/D 186 1 L9-13/3/D 256 1 15 L9-15/1/D 97 2 L9-15/2/D 186 1 L9-15/3/D 256 1 16 L9-16/1/D 97 2 L9-16/2/D 186 1 L9-16/3/D 256 1 20 L9-20/1/D 97 2 L9-20/2/D 186 1 L9-20/3/D 256 1 25 L9-25/1/D 107 2 L9-25/2/D 199 1 L9-25/3/D 285 1 30 L9-30/1/D 110 2 L9-30/2/D 199 1 L9-30/3/D 285 1 32 L9-32/1/D 110 2 L9-32/2/D 199 1 L9-32/3/D 285 1 35 L9-35/1/D 115 2 L9-35/2/D 199 1 L9-35/3/D 285 1 40 L9-40/1/D 115 2 L9-40/2/D 212 1 L9-40/3/D 310 1 L9 Miniature Circuit Breaker Features: • UL-489 listed for Branch Circuit protection and CSA 22.2 No. 5.1 Approved • Thermal magnetic protection • Trip characteristic based on 40°C ambient for UL/CSA • 10kA interrupting rating • All ratings are HACR rated (SWD rated up to 20 A) • Finger safe design (front) • DIN rail mounting ➊ Rated 415V AC, 48V DC, IEC max/min meets IEC 60947-2 for miniature circuit breakers. ➋ 1-Pole 277V AC, 48V DC 0.5…20A; 240V AC, 48V DC 30…40A ➌ 2-Pole (series) 96VDC 0.5...40A Discount Schedule B-8 L9 SSNA9000 Circuit Protection M M21 Accessories Series L9 UL489 Miniature Circuit Breakers Accessories Module Description Selectable Two Pole Auxiliary Contact or Auxiliary / Signal Alarm Module ➊➋ For use with… Contact Rating All L9s & Shunt Trips UL/CSA Max. volt 2A, 240V AC 0.5A, 110V DC Connection Diagrams Two pole auxiliary mode Catalog Number Price LX-AHS3 71 L9-ABH12 66 L9-ASTA1 76 L9-ASTA2 76 L9-AALOA 20 Auxiliary / Signal alarm mode Two Pole Auxiliary Contact ➌ All L9s & Shunt Trips 110…415V AC 110...230V DC Shunt Trip – • Remotely trips the device • Installs on left side of L9 UL/CSA Max. volt 2A, 230V AC 0.5A, 110V DC All L9s 12…110V AC 12...60V DC Padlock Hasp – •Fits securely over switch handle. Prevents unauthorized activation of L9 during maintenance + X Shunt L9-AAST... X X Allowable Combinations of Field Installed Modules (1) Selectable Two Pole Auxiliary Contact Module / Auxiliary & Signal Alarm Contact Module (1) Shunt Trip Module (1) Auxiliary Contact Module + (1) Shunt Trip Module L9-... All modules install on the left side of the Circuit Breaker. X X X Allowable Combinations of Accessories per Circuit Breaker (read left to right) ➊ Use of auxiliary or signal contact limits the circuit breaker to a maximum voltage of 240VAC for UL/CSA applications. ➋L9 Circuit Breakers are restricted to operate at a maximum of 240VAC for UL/CSA applications when attached to the LX-AHS3. ➌L9 Circuit Breakers are permitted to operate at a maximum of 480Y/277VAC for UL/CSA applications when attached to the L9-ABH12. M22 Discount Schedule B-8 SSNA9000 L9 Circuit Protection M Auxiliary Contacts X All L9s Accessories Series L9 UL489 Miniature Circuit Breakers L9 Bus Bars 7 Accessories ➊➌➍ Description No. of Poles Bus Bar No. of Phases Length ➋ UL Max. Amps @ 40°C No. of Circuit Breakers Catalog Number Price 106 mm 6 L9-AACL106 66 212 mm 12 L9-AACL112 105 18 318 mm 18 L9-AACL118 142 6 106 mm 3 L9-AACL206 77 6 12 1 6 L9-AACL212 123 18 318 mm 9 L9-AACL218 174 6 106 mm 2 L9-AACL306 89 212 mm 4 L9-AACL312 143 318 mm 6 L9-AACL318 203 12 12 2 3 18 212 mm 80 Pkg Qty 10 L9 Bus Bar Accessories Description No. of Poles Wire Range Catalog Number Price Pkg Qty L9-AACLT35 51 10 L9-AACLPS 7 10 Terminal Lug 1 for Circuit Breaker Termination #14 ... #2 AWG 2.5 ... 35MM2 Protective Cover for unused termination 3 pole set (May be separated) ~ Other Accessories Accessory Description Catalog Number Price Top Hat, low profile (price per rail) 3F Top Hat, high profile (price per rail) 3AF See page A58 DIN-rail - 2 meter lengths (6' 6") ➊ UL 489 recognized (DIHS E304757), CE ➋ Total length from Circuit Breaker to Circuit Breaker when mounted on bus bars (not measurement of bus bar length). ➌ Bus bar can not be cut. ➍ Use of multiple bus bars permitted with overlap joint. Maximum of two joints permitted. Discount Schedule B-8 L9 SSNA9000 Circuit Protection M M23 Technical Information Series L9 UL489 Miniature Circuit Breakers Technical Information General Data Number of Poles Standards 1, 2 and 3 UL 489 CSA 22.2 No. 5.1 IEC 60 947-2 UL Listed Circuit Breaker (File Number E304753) CSA Certified, CE Yes Yes (0.5...20 A) UL/CSA: 40°C IEC: 30°C UL/CSA: 10 000 AIC IEC - lcu: 15 000 A UL/CSA: 0.5...20 A, 480Y/277V AC 0.5...40 A, 240V AC 0.5...40 A 48V DC 1-pole 0.5...40 A 96V DC 2-pole IEC: 0.5...40 A, 415V AC 48V DC Finger-safe from front: -IP20 per IEC 529 from front -IP00 at wire terminals 1960V AC 25 G Half sine wave for 11 ms (3 axis) Frequency range: 10...200 Hz Max. Amplitude (p-p) = 0.030” Max. Acceleration = 5 G 2 hours each of 3 axis -5...55°C (23...131°F) (non-condensing) C curve (Inductive) 5...10 IN D curve (Highly Inductive) 10...20 IN -40..85°C (-40...185°F) 1 wire: #18...6 AWG 2 wires: #18...10 AWG #18...12 AWG: 21 lb-in. #10...8 AWG: 25 lb-in. #6 AWG: 36 lb-in. #2 PoziDrive 0.5 in Certifications HACR Rating (USA/Canada) SWD Rating (USA/Canada) Calibration Temperature Rated Interrupting Capacity Rated Tripping Current Degree of Protection Dielectric Strength Shock Vibration Normal Operating Environment Trip Curves Shipment and Short-Term Storage Limits Wire Size Terminal Torque Recommended Wire Strip Length Auxiliaries Auxiliary Contact, LX-AHS3, L9-ABH12 Yes Yes Yes 3A, 250V AC (AC13) 0.5A, 110V DC 2A, 240V AC ➊ 0.5A, 110V DC Cable CSA/UL Certifications IEC 60 947-2 Compliance CE IEC Max. Voltage UL/CSA Max. Voltage Connection Shunt Trip Module L9-ASTA1 Yes Yes Yes 110...415V AC 110...230V DC 110...415V AC 110...230V DC Cable Shunt Trip Module L9-ASTA2 Yes Yes Yes 12...110V AC 12...60V DC 12...110V AC 12...60V DC Cable Mechanical Life-span [ops] Aux...LX-AHS3 6000 Shunt Trip L9-AASTA... 4000 0.5...2.5 (18...14) 0.5...2.5 (18...14) 0.8 / 7 45 / 0.1 1.0...6 (18...10) 1.0...6 (18...10) 2.8 / 25 155 / 0.4 Terminal type Wire size solid /stranded Tightening torque Weight 1 conductor 2 conductors [Nm] / [lb-in] [g] / [lbs] ➊L9 Circuit Breakers are restricted to operate at a maximum of 240VAC for UL/CSA applications when attached to the LX-AHS3. M24 Discount Schedule B-8 SSNA9000 L9 Circuit Protection M Terminations Dimensions Series L9 UL489 Miniature Circuit Breakers L9 Miniature Circuit Breakers (Series L9…C & D) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 1 pole 2 pole 3 pole Two Pole Auxiliary Contact (w/ Signal Alarm Contact) Two Pole Auxiliary Contact 45 96 44 71.6 5.5 10 53 60 LX-AHS3 L9-ABH12 Shunt Trip (L9-AASTA...) L9-AASTA... Discount Schedule B-8 L9 SSNA9000 Circuit Protection M M25 Dimensions Series L9 UL489 Miniature Circuit Breakers L9 -AACL_06 - 6 Pole Bus Bars Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. L9-AACL_12 - 12 Pole Bus Bars L9-AACL_18 - 18 Pole Bus Bars L9-AACLT35 - Terminal Lug L9-AACLPS - Protective Cover 17,6 3,55 M 17,6 7 L9 16 M26 Discount Schedule B-8 BLACK PR INT ING SSNA9000 Circuit Protection 24 Dimensions Series L9 UL489 Miniature Circuit Breakers Applying L9 Bus Bars & Accessories L9 SSNA9000 Circuit Protection M Discount Schedule B-8 M27 Dimensions Series L9 UL489 Miniature Circuit Breakers Applying L9 Bus Bars & Accessories L9 SSNA9000 Circuit Protection M M28 Discount Schedule B-8 Methods of Applying CIRCUIT PROTECTION This information is provided to aid in proper system design and utilization of circuit protection devices in North American applications. Be sure to consider all applicable local and national codes for your particular installation. L8/L9 SSNA9000 Circuit Protection M M29 Circuit Protection Methods Series L8 Supplementary Protectors Applying L8 Supplementary Protectors in accordance with UL & NEC Guidelines UL 508A, a procedure covering industrial control panels, offers guidelines in applying supplementary overcurrent protective devices. The general areas of acceptability are in the primary and secondary protection of control transformers, and also control circuit protection. Other uses of Mini-CB’s may be submitted to UL for further investigation. Per UL 508A, before utilizing a supplementary device for control transformer overcurrent protection, the supplementary device must meet the following restrictions: Unless otherwise specified it is used with protection, either fuse or circuit breakers upstream from the supplementary device, rated at 400 percent of the supplementary protector rating but not less than 20A for device rated 150V or less and 15A for devices rated 150V or more. (Reference: UL 508A procedure prescribed only) Protection of Control Transformers Control transformers can generate an almost infinite current spike on start-up while attempting to overcome core saturation. Only the resistance of the control transformer windings and the inductance of the circuit limit the large current draw. The inrush spikes are of short duration (1/8 to 1/4 of a cycle), typically reaching between 8~20 x In. Therefore, selecting a Mini-CB with the proper current rating and high inrush trip characteristics is ideal to avoid nuisance tripping. Sprecher+Schuh Series L8 “C” & “D” type Supplementary Protectors offer high inrush capabilities from 5~10 x In and 10~20 x In respectively. Selecting the proper Mini-CB current ratings for the primary and secondary protection of control transformers (per UL/NEC) is as follows: Secondary Overcurrent Protection for Control Transformers Control Circuits: If the rated secondary current is less than 9 amps, the maximum rating of the overcurrent device is 167%. If 9 amps or more, the maximum rating of the overcurrent device is 125%. The next larger size of an overcurrent device may be used if 125% does not correspond to a standard size. L8/L9 Circuit Protection M Primary Overcurrent Protection for Control Transformers Control Circuits: If the rated primary current is less than 2 amps, the maximum rating of the overcurrent device is 500%. If the rated primary current is more than 2 amps, the maximum rating of the overcurrent device is 250%. M30 (Reference: UL 508 32.7, UL 845 11.16 & 11.17, NEC 43072(c) exception No. 2, 450-3(b) 1 & 2) Example (see table for more calculated results) Primary & Secondary Protection of a Control Transformer: 50VA Pri. 480/ Sec. 120V Primary Mini-CB Selection • 50VA/480V = 0.10A rated transformer primary current • 0.10A is less than 2, therefore may increase up to 500% • 0.10A x 500% = 0.52A, Select L8-.5/2/D (0.5 amp 2-Pole) • Upstream BCPD must be rated at 400% of the selected Mini-CB rating • 0.5A x 400% = 2A, since rated below 15A at 150V or more, the minimum BCPD is 15A per NEC-240.6 Primary Control Transformer Calculations (480 / 240V) Transformer VA Primary Volts Rated Amps ➊ Selected L8 Mini-CB Maximum Upstream BCPD ➋ 50 480 0.10 0.5 15A 100 480 0.21 1 15A 150 480 0.31 1 15A 200 480 0.42 2 15A 250 480 0.52 2 15A 300 480 0.63 3 15A 500 480 1.04 5 25A 1000 480 2.08 5 25A 50 240 0.21 1 15A 100 240 0.42 2 15A 150 240 0.63 3 15A 200 240 0.83 4 15A 250 240 1.04 5 25A 300 240 1.25 6 25A 500 240 2.08 5 25A 1000 240 4.17 10 60A ➊ If the rated primary current is less than 2 amps, the maximum rating of the overcurrent device is 500%. If the rated primary current is more than 2 amps, the maximum rating of the overcurrent device is 250%. ➋ Minimum standard BCPD ampere rating is 15A per NEC-240.6. SSNA9000 Sprecher+Schuh Series L8 Supplementary Protectors are recognized by Underwriters Laboratories (UL). Representative samples of this product have been evaluated by UL and meet applicable US safety standards. In general, the UL Component Recognition service covers the evaluation of components that will later be used in a complete product or system. L8 Supplementary Protectors are defined as UL Recognized supplementary overcurrent protective devices under the standard of UL 1077. Circuit Protection Methods Series L8 Supplementary Protectors Applying L8 Supplementary Protectors in accordance with UL & NEC Guidelines (continued) Secondary Supplementary Protectors Selection • 50VA/120V = 0.42A rated transformer secondary current • 0.42A is less than 9, therefore may increase up to 167% • 0.42A x 167% =0.70A, Select L8-1/1/D or L8-1/1/C (1 amp 1-Pole) Secondary Control Transformer Calculations (120 / 24V) Transformer VA Secondary Volts Rated Amps ➊ Selected L8 Mini-CB 50 120 0.42 1 100 120 0.83 2 150 120 1.25 2 200 120 1.67 3 250 120 2.08 4 300 120 2.50 4 500 120 4.17 7 1000 120 8.33 13 50 24 2.08 4 100 24 4.17 7 150 24 6.25 10 200 24 8.33 13 250 24 10.42 13 300 24 12.50 16 500 24 20.83 30 1000 24 41.67 50 Protection of Control Circuit Devices Control circuit devices can also generate inrush currents during startup, though not as intense as control transformers. Devices such as control relays, starter coils, and solenoids exhibit typical inrush levels between 6~10 x In. Also, protection of conductor wires or low-level signal devices such as PLCs may exhibit even lower inrush levels ranging from 3~5 x In. Depending on the inrush, an Mini-CB with a type “B” or “C” trip characteristic will perform the task. Control Circuit Conductor Protection The relationship between the control circuit conductor size and rating of the protective device must be in compliance with the tabulated data per UL 508. (Reference: UL 508A procedure prescribed only) Where can supplementary overcurrent protectors not be used? • Branch Circuit Protection Device (BCPD) • Power Transformer Primary Protection • Power Transformer Secondary Protection • Protection of Loads such as for Motors, Heater, Lamps, and General use Supplementary protectors may be submitted to UL for further investigation for other uses. ➊ If the rated secondary current is less than 9 amps, the maximum rating of the overcurrent device is 167%. If 9 amps or more, the maximum rating of the overcurrent device is 125%. M31 L8/L9 SSNA9000 Circuit Protection M Circuit Protection Methods Series L9 UL489 Miniature Circuit Breakers Applying L9 UL489 Miniature Circuit Breakers in accordance with UL & NEC Guidelines (continued) Description Available Short Circuit Current L9 Circuit Breakers for Branch Circuit protection are available one (1)-, two (2-), and three (3-) pole construction and are rated 0.5 to 40A at 240VC AC and 0.5 to 25A at 480Y/277V AC for North American applications (UL 489 and CSA 22.2 No. 5.1). For IEC applications, the products are rated 415V AC 0.5 to 40A. The L9 circuit breakers should only be applied in those applications in which the available short-circuit (or fault) current is less than or equal to 10,000 A. Thermal Magnetic Circuit Breakers The L9 Thermal Magnetic Circuit Breakers are general-purpose devices suitable for the majority of industrial, inverse time circuit breaker applications. They combine thermal and magnetic trip actions and provide accurate overload and short-circuit protection for conductors and connected equipment. Region IEC Regions North America (UL 489 & CSA 22.2 No. 5.1) Max. Voltage Current Range 415V AC 0.5...40 A 48V DC 0.5...40 A 240V AC 0.5...40A 480Y/277V AC 0.5...25A 1-pole 48V DC 0.5...40 A 2-pole 96V DC 0.5...40 A Circuit Breaker Application Information Application Considerations Selection of a L9 circuit breaker with appropriate circuit protection includes consideration of: The selection of a specific ampere rating for a specific application is dependent on the type of load and duty cycle and is governed by the National Electric Code (Canadian Electric Code) and UL/CSA. In general, the codes require that overcurrent protection is at the current supply and at points where wire sizes are reduced. In addition, the codes state that conductors be protected according to their current carrying capacity. There are specific situations that require application consideration, such as motor circuit, and guidelines for the selection for transformer protection. ● Circuit Voltage ● Circuit Frequency ● Available Short Circuit Current ● Continuous Current Rating ● Application Considerations ● Special Operating Conditions Circuit Voltage The L9 circuit breakers are rated by voltage class. Applications should not exceed the listed voltage and current range. Circuit Frequency The L9 circuit breakers may be applied to frequencies of 50 and 60 Hz without derating. For applications above 60 Hz, contact Sprecher + Schuh with specific application information for the derating of the circuit breakers. The L9 circuit breakers are "non 100% rated" as defined UL 489, para 7.1.4.2. As such, the circuit breaker's rating should be loaded to no more than 80% if used with continuous loads. Branch Circuits L9 circuit breakers may be used to protect branch circuits. A branch circuit is the wiring portion of a system extending beyond the final overcurrent device protecting the circuit. Guidelines established in NEC, CED, UL and CSA should be used to determine the specific device. 1. Motor Branch Circuit L9 circuit breakers are not horsepower rated because they are able to safely interrupt currents far in excess of the locked rotor value for a selected motor. This ability is recognized in the codes and standards and is also established by the UL and CSA tests described in UL 489 and CSA 22.2 No 5.1 standards. M L8/L9 Circuit Protection L9 circuit breakers may be used for transformer protection following the guidelines established. References: NEC 450 and UL 489. Also see CEC and appropriate Canadian Standards. References: NEC 450 and UL 489. Also see CEC and appropriate Canadian Standards. M32 SSNA9000 2. Transformer Protection Circuit Protection Methods Series L9 UL489 Miniature Circuit Breakers Applying L9 UL489 Miniature Circuit Breakers in accordance with UL & NEC Guidelines (continued) 3. Heater Load, Lighting, and Other Load Protection L9 circuit breakers may be used for protection of heater loads, lighting loads and other loads following the guidelines established. References: NED Article 31 and UL 508A. Also see CEC and appropriate Canadian Standards. Coordinated Overcurrent Protection The L9 device is designed to substantially reduce the amount of letthrough-current and the resulting let-through-energy that can damage protected components. The L9 has the ability to interrupt short circuit current within the first half cycle of the fault. Limiting letthrough current and energy will protect against the harmful effects of overcurrent and is focused primarily on avoiding the following: • Excessive Heat • Mechanical Damage SWD Rating Both of these factors are proportional to the square of the current. Thermal energy is proportional to the square of the RMS value and magnetic forces are proportional to the square of the peak value. The most effective way to provide protection is to substantially limit letthrough-energy. This provides the following advantages • Far less damage at the location of the short circuit. • Fast electric separation of a faulty unit from the system, especially power supplies connected in parallel that are switched off when the voltage of the power bus drops below a certain level. • Far less wear on the miniature circuit breaker itself. This means more safe interruptions. • Better protection of all components in the short circuit path. • Far wider range of selective action when used with an upstream protective device. (No nuisance shut downs from feeder line interruptions, causing a blackout in all connected branches.) The following values are applicable to the whole product range. • Frequency: 50/60 Hz L9 breakers (0.5 ... 20A) are rated as SWD and as such may be applied to switch fluorescent lighting loads up to their current and voltage maximum. The values are derived from worst case testing of D trip 40 A @ 240V AC and D trip 25 A @ 480Y/277V AC. Where an orderly shutdown is required to minimize the hazards to personnel and equipment, a system of coordination based upon the faulted or overloaded circuit is isolated by selective operation of only the overcurrent protective device closest to the overcurrent condition. The user should select devices that meet this requirement. References: NEC 240.12. Also see CEC. HACR Rating L9 Circuit Breakers are rated as Heating, Air Conditioning and Refrigeration circuit breakers as defined by UL489, paragraph 6.7 and may be used in this type of application. Current Limiting L9 Circuit Breakers are rated as current limiting circuit breakers as defined by UL 489, paragraph 8.6. The L9 line features the ability to achieve short circuit interruptions far more effectively than conventional breakers. In conventional circuit breakers, the short circuit interruption time required is approximately one or two half cycles of an AC sine wave. When the contacts open, the resulting arc continues to burn until the current level passes through zero. The arc may re-ignite because of the insufficient width of the contact gap. The current that flows until the arc is extinguished produces a heating effect proportional to the I2t value (let-through-energy) of the fault current. Threshold Current Intermediate Current High Interrupt Current Vrms 240 V (D40) 480Y/277V (D25) Symmetrical (kA) 2.6 1.625 I peak (kA) 2.9 2.0 I2t (kA2s) 18.0 12.0 Symmetrical (kA) 5.0 5.0 I peak 4.2 4.6 I2t 24.0 38.0 Symmetrical (kA) 10.0 10.0 I peak 6.2 6.2 43.0 60.0 I2t (kA2s) (kA2s) L8/L9 SSNA9000 Circuit Protection M M33 Circuit Protection Methods Series L9 UL489 Miniature Circuit Breakers Applying L9 UL489 Miniature Circuit Breakers in accordance with UL & NEC Guidelines (continued) Determining Ratings The standard tripping characteristics for the L9 Series is Type C Type C has a magnetic trip activated at 5...10 times the rated current of the circuit breaker. The reference temperature for the thermal tripping characteristics is 40°C. The Type C characteristics will suit most applications. In rare occurrences when the Type C characteristics does not fully meet the application, the following additional magnetic trip characteristics is available. Type D allows for transient approximately twice as high as the standard Type C. Use the table and graphs to determine the current rating for the breaker if the ambient is significantly different than 40°C. Device Marked Current Rating in (A) @ 40°C 0.5 1.0 1.5 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 13.0 15.0 16.0 20.0 25.0 30.0 32.0 40.0 In (A) at higher Ambient Temperature 15°C 20°C 25°C 30°C 40°C 50°C 55°C 0.6 1.1 1.7 2.2 3.3 4.4 5.5 6.6 7.7 8.8 11.0 14.3 16.5 17.6 22.0 27.5 33.0 35.2 44.0 0.5 1.1 1.6 2.2 3.2 4.3 5.4 6.5 7.6 8.6 10.8 14.0 16.2 17.3 21.6 27.0 32.4 34.6 43.2 0.5 1.1 1.6 2.1 3.2 4.2 5.3 6.4 7.4 8.5 10.6 13.8 15.9 17.0 21.2 26.5 31.8 33.9 42.4 0.5 1.0 1.6 2.1 3.1 4.2 5.2 6.2 7.3 8.3 10.4 13.5 15.6 16.6 20.8 26.0 31.2 33.3 41.6 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 40 0.5 1.0 1.4 1.9 2.9 3.8 4.8 5.8 6.7 7.7 9.6 12.5 14.4 15.4 19.2 24.0 28.8 30.7 38.4 0.5 0.9 1.4 1.9 2l.8 3.8 4.7 5.6 6.6 7.5 9.4 12.2 14.1 15.0 18.8 23.5 28.2 30.1 37.6 Note: The table shows the corrected values of t he rated current dependent on the ambient temperature. L8/L9 SSNA9000 Circuit Protection M M34 Circuit Protection Methods Series L8 and L9 Defining Electrical Standards Relating to Protection Devices ➊ ➎ ➋ ➌ ➏ ➐ ➐ ➍ Sprecher + Schuh Products ➊ Branch Circuit Protection Device (BCPD) Acceptable components • Branch circuit protection device (UL489) • Self-protected Type E manual motor controller (UL508-E) ➊ L10 Disconnect Switch ➋ Control Transformer Primary Protection Acceptable components • UL-listed fuses (UL512) • Branch circuit protection device (UL489) • Supplementary protective device (UL1077) ➋ ➌ ➍ ➎ ➏ FH8 Fuse Holder ➌ Control Transformer Secondary Protection Acceptable components • Supplementary protective device (UL1077) • Miscellaneous, miniature and micro fuses ➍ Supplementary Circuit Protection Acceptable components • Supplementary protective device (UL1077) • Branch circuit protection device (UL489) • Miscellaneous, miniature and micro fuses ➊ ➏ ➐ KT7 Motor Circuit Protector ➋ ➌ ➍ L8 Supplementary Protector ➎ Power Transformer Fuse/Branch Circuit Protection Acceptable components • Branch circuit protection device or power-related transformer fuses (UL489/512) Acceptable components • Branch circuit protection device or power-related transformer fuses (UL489/512) ➐ Motor Load Protection V7 Fuse Blocks ➊ ➋ ➌ ➍ ➎ ➏ L9 Miniature Circuit Breaker M L8/L9 SSNA9000 • Manual motor controllers (UL508-E) ➌ ➍ Circuit Protection ➏ Power Transformer Fuse/Branch Circuit Protection M35 Circuit Protection Methods Series L8 and L9 Defining Electrical Standards Relating to Protection Devices Circuit protection devices should be applied in accordance with the product specifications, as well as local and national electrical codes. Sprecher+Schuh protection devices offer equipment manufacturers a product that meets both US and international protection standards. A variety of Sprecher+Schuh Protection Devices are approved by Underwriters Laboratory’s standards and are applicable for use under the guidelines of the National Electric Code (NEC). Internationally, Sprecher+Schuh Protection Devices are CE marked and meet CSA and IEC standards for worldwide acceptance. Sprecher+Schuh Protection Devices are an excellent choice for a wide variety of electrical protection circuits. See the listings below to gain a broader understanding of additional electrical standards pertaining to other types of circuit protection. UL 508 Manual Motor Controllers A manual motor controller is suitable for use as an ON/OFF (make/break) controller for motors and other loads. These devices also have an overload tripping function which must be compliant with applicable tests for an overload relay. In addition, an overload tripping device must operate independently of the manipulation of the handle (trip free). Products evaluated according to the Canadian Standards Association (CSA), which are intended to protect branch circuits in accordance with the Canadian Electric Code (CEC). The CSA C22.2 No. 5.1 standard is closely related to the UL 489 standard. ® UL 1077 Supplementary Protection UL recognized supplementary protectors evaluated according to UL 1077 standard. Supplementary protectors are intended for use as overcurrent protection within an appliance or other electrical equipment where branch circuit protectors shall not be used as substitutes for UL 489 branch circuit protective devices. General uses: control circuit components such as relay coils, starter coils, timers and remote solenoids... etc.; control transformers protection (primary & secondary); sensitive internal electronic circuitry. CSA C22.2 No. 235 The CSA C22.2 No. 235 Standard is closely related to the ® UL 1077 Supplementary Protector standard. IEC 60947-2 Standard Electrical standards for industrial applications using circuit protection. A listed Manual Motor Controller, additionally marked “Suitable as a Motor Disconnect,” shall be permitted as a disconnecting means where installed between the final motor branch-circuit short-circuit, transformer protection, device and the motor. General uses: control circuit, transformer protection, motor loads, general use loads, lighting loads, resistive loads. Although Sprecher+Schuh Supplementary Protectors are not listed as UL 508 manual motor controllers, Sprecher + Schuh offers our KT7 Motor Controller series, which does meet the UL 508 standard at a competitive price. UL 489 Branch Circuit Protection Products UL Listed for Branch Circuit Protection, which are approved and evaluated according to the UL 489 Standard for “Molded Case Circuit Breakers” (usually applicable at 240V maximum when associated with Supplementary Protectors). General uses: Branch Circuit Protection Device (BCPD), protect motor loads, protect external loads such as receptacles or HVAC & refrigeration equipment. CSA C22.2 No. 5.1 L8/L9 SSNA9000 Circuit Protection M M36 Series FH8 DIN-rail Mounted Fuse Holders Sprecher + Schuh’s FH8 Fuse Blocks feature the latest enclosed design for the ultimate in safety and convenience. Built for control and power circuits, the FH8 line is DIN-rail mountable, compact and reliable. Both AC and DC models are available, with and without blown fuse indication. The new design standard for fuse block overcurrent protection Sized for many applications FH8 Fuse Blocks are available in one, two and three pole configurations for the following fuse types: •Class CC •Midget; 1-1/2 x 13/32 •DC rated fuses up to 30A •Class J 30A fuses •Class J 60A fuses All AC fuse blocks are rated to 600V, with 12-72V AC/DC models available for midget and Class CC fuses. All devices carry a withstand rating to 200kA. Midget fuse blocks are rated to 50kA. ® New enclosed design offers many advantages Unlike “open” fuse blocks of the past that were extremely dangerous, the enclosed design of the FH8 series features IP2 dead-front construction under IEC and DIN standards. In operation, there is no access to live fuses or fuse clips. With the flick of a finger, fuse access is gained via a levered compartment on the front of the holder that isolates the fuse from the line power. This makes fuse changeout quick, easy, convenient... and safe. Other great features The FH8 line is compact, saving up to 15% in panel space over conventional fuse blocks. The entire line is also DIN-rail mountable, resulting in extra savings in panel building time. All models are available with blown fuse indication, saving time on maintenance and troubleshooting. The bodies are made up of tough and durable polyamide, known for its exceptional insulating properties. International approvals Class CC and J fuse holders are UL listed for branch circuit protection in electrical distribution systems. They are excellent for small motor loads and group protection of small motors. Midget holders are UL recognized. The entire line is CSA Approved and carries the CE Mark for use in international markets. 18mm 18mm 36mm 40mm Midget Class CC Class J (30A) Class J (60A) (≈0.71") (≈0.71˝) (≈1.41˝) (≈1.57˝) M37 FH8 SSNA9000 Circuit Protection M Series FH8 Fuse Holders For Midget Fuses DIN-rail Mounted Fuse Holders – Midget Fuses (1-1/2 x 13/32) ➊➋ 2.51" (64mm) 3.19" (81mm) Three Pole 3.19" (81mm) Ordering and Technical Information 2.51" (64mm) 0.71" (18mm) FH8-1PM30 FH8-1PM30-L FH8-1PM30-D1 19 27 27 6 6 6 2.51" (64mm) 1.41" (36mm) Price Ea. Pkg (Std Pkg) Qty Catalog Number Catalog Number Fuse Holder Without Blown Fuse LED With Blown Fuse LED 12-72V AC/DC (with LED indicator) Two Pole 3.19" (81mm) One Pole 2.13" (54mm) Price Ea. Pkg (Std Pkg) Qty Catalog Number FH8-2PM30 FH8-2PM30-L 38 57 3 3 FH8-3PM30 FH8-3PM30-L See page A58 12 12 3F 3AF See Section N 50 10 V7-EA35 V7-EAH35 Price Ea. Pkg (Std Pkg) Qty 57 85 2 2 See page A58 12 12 See Section N 50 10 Accessories DIN-rail Top Hat, low profile (priced per rail) Top Hat, high profile (priced per rail) 3F 3AF End Anchors DIN Rail — Normal Duty DIN Rail — Heavy Duty V7-EA35 V7-EAH35 See page A58 12 12 3F 3AF See Section N 50 10 V7-EA35 V7-EAH35 Fuse Block Specifications Approvals ® Voltage Rating 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 30 A 30 A 30 A 30 A 30 A 30 A #16–#4 AWG Cu 1.5…25mm2 #16–#4 AWG Cu 1.5…25mm2 #16–#4 AWG Cu 1.5…25mm2 #16–#4 AWG Cu 1.5…25mm2 #16–#4 AWG Cu 1.5…25mm2 #16–#4 AWG Cu 1.5…25mm2 Wire Strip Length 600V AC/DC 0.44" (11 mm) 0.44" (11 mm) 0.44" (11 mm) Recommended Tightening Torque 18...22 lb-in. (2...2.5 Nm) 18...22 lb-in. (2...2.5 Nm) 18...22 lb-in. (2...2.5 Nm) Working Voltage (indicating circuit) FH8-1PM30-D1 110…600V AC/DC 12…72V AC/DC 110…600V AC/DC ~ 110…600V AC/DC ~ Leakage Current (indicating circuit) 2mA 2mA 2mA Withstand Rating 50kA 50kA 50kA Fuse Type Operating Temperature Contact Material Common Midget Fuse Applications • Transformer secondary protection • Supplemental protection of: - Control circuits - Lighting - Solenoids Midget fuses only ➊ Midget fuses only ➊ Midget fuses only ➊ –4°…+130°F (–20°…+55°C) –4°…+130°F (–20°…+55°C) –4°…+130°F (–20°…+55°C) Silver, Ag Silver, Ag Silver, Ag Typical Midget Fuse Dimensions ➊ SSNA9000 FH8 Circuit Protection M ® 600V AC/DC Maximum Current Wire Range (Rated Cross Section) ® ➊Fuses not offered by Sprecher + Schuh. ➋FH8 UL File E196851, CSA 236535 M38 Discount Schedule B-7 Series FH8 Fuse Holders For Class CC Fuses DIN-rail Mounted Fuse Holders – Class CC Fuses ➊➋➌ 2.51" (64mm) 3.19" (81mm) Ordering and Technical Information 2.51" (64mm) 0.71" (18mm) FH8-1PC30 FH8-1PC30-L FH8-1PC30-D1 17 26 26 6 6 6 2.51" (64mm) 1.41" (36mm) Price Ea. Pkg (Std Pkg) Qty Catalog Number Catalog Number Fuse Holder Without Blown Fuse LED With Blown Fuse LED 12-72V AC/DC (with LED indicator) Three Pole 3.19" (81mm) Two Pole 3.19" (81mm) One Pole 2.13" (54mm) Price Ea. Pkg (Std Pkg) Qty Catalog Number FH8-2PC30 FH8-2PC30-L 38 56 3 3 FH8-3PC30 FH8-3PC30-L See page A58 12 12 3F 3AF See Section N 50 10 V7-EA35 V7-EAH35 Price Ea. Pkg (Std Pkg) Qty 57 85 2 2 See page A58 12 12 See Section N 50 10 Accessories DIN-rail Top Hat, low profile (priced per rail) Top Hat, high profile (priced per rail) 3F 3AF End Anchors DIN Rail — Normal Duty DIN Rail — Heavy Duty V7-EA35 V7-EAH35 See page A58 12 12 3F 3AF See Section N 50 10 V7-EA35 V7-EAH35 Fuse Block Specifications Approvals Voltage Rating Maximum Current Wire Range (Rated Cross Section) ® 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 30 A 30 A 30 A 30 A 30 A 600V AC/DC 30 A #16–#4 AWG Cu 1.5…25mm2 #16–#4 AWG Cu 1.5…25mm2 #16–#4 AWG Cu 1.5…25mm2 #16–#4 AWG Cu 1.5…25mm2 #16–#4 AWG Cu 1.5…25mm2 #16–#4 AWG Cu 1.5…25mm2 0.44" (11 mm) 0.44" (11 mm) 0.44" (11 mm) Recommended Tightening Torque 18...22 lb-in. (2...2.5 Nm) 18...22 lb-in. (2...2.5 Nm) 18...22 lb-in. (2...2.5 Nm) Working Voltage (indicating circuit) FH8-1PC30-D1 110…600V AC/DC 12…72V AC/DC 110…600V AC/DC ~ 110…600V AC/DC ~ Leakage Current (indicating circuit) Withstand Rating Fuse Type Operating Temperature Contact Material 2mA 2mA 2mA 200kA 200kA 200kA Class CC fuses only ➊ Class CC fuses only ➊ Class CC fuses only ➊ –4°…+130°F (–20°…+55°C) –4°…+130°F (–20°…+55°C) –4°…+130°F (–20°…+55°C) Silver, Ag Silver, Ag Silver, Ag Common Class CC Applications • Control transformer protection • Motor circuits • Branch circuit protection • Lighting loads • General purpose loads • Heating loads Typical Class CC Fuse Dimensions ➊ M ➊Fuses not offered by Sprecher + Schuh. ➋All major fuse brands and current ranges have been evaluated for this fuse holder. Due to the heat they generate, the following fuses must be derated: Ferraz Shamut ATQR 1.25 I = 0.42 A max. Ferraz Shamut ATQR 1.40 I = 0.47 A max. ➌FH8 UL File E196851, CSA 236535 Discount Schedule B-7 FH8 SSNA9000 ® Circuit Protection Wire Strip Length ® M39 Series FH8 Fuse Holders For Class J Fuses, 30A DIN-rail Mounted Fuse Holders – Class J Fuses, 30A ➊➋ 2.76" (70mm) 2.76" (70mm) 1.41" (36mm) Catalog Number FH8-1PJ30 FH8-1PJ30-L 38 44 6 6 2.76" (70mm) 2.83" (72mm) Price Ea. Pkg (Std Pkg) Qty Catalog Number 4.65" (118mm) Ordering and Technical Information Fuse Holder Without Blown Fuse LED With Blown Fuse LED Three Pole 4.65" (118mm) Two Pole 4.65" (118mm) One Pole 4.25" (108mm) Price Ea. Pkg (Std Pkg) Qty Catalog Number FH8-2PJ30 FH8-2PJ30-L Price Ea. Pkg (Std Pkg) Qty 79 91 3 3 FH8-3PJ30 FH8-3PJ30-L 118 136 2 2 See page A58 12 12 3F 3AF See page A58 12 12 See Section N 50 10 V7-EA35 V7-EAH35 See Section N 50 10 Accessories DIN-rail Top Hat, low profile (priced per rail) Top Hat, high profile (priced per rail) 3F 3AF End Anchors DIN Rail — Normal Duty DIN Rail — Heavy Duty V7-EA35 V7-EAH35 See page A58 12 12 3F 3AF See Section N 50 10 V7-EA35 V7-EAH35 Fuse Block Specifications Approvals Voltage Rating ® 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 30 A 30 A 30 A 30 A 30 A 30 A #14–#1 AWG Cu 2.5…50mm2 #14–#1 AWG Cu 2.5…50mm2 #14–#1 AWG Cu 2.5…50mm2 #14–#1 AWG Cu 2.5…50mm2 #14–#1 AWG Cu 2.5…50mm2 #14–#1 AWG Cu 2.5…50mm2 0.8" (20 mm) 0.8" (20 mm) 0.8" (20 mm) Recommended Tightening Torque 31...35 lb-in. (3.5...4 Nm) 31...35 lb-in. (3.5...4 Nm) 31...35 lb-in. (3.5...4 Nm) Working Voltage (indicating circuit) 110…600V AC/DC 110…600V AC/DC 110…600V AC/DC Leakage Current (indicating circuit) 2.0 mA 2.0 mA 2.0 mA Withstand Rating Fuse Type Operating Temperature Contact Material Circuit Protection FH8 600V AC/DC Common Class J Applications • Motor circuits • Feeders and mains • Branch circuit protection • Lighting, heating and general loads • Power transformers • Control transformers • Control circuits 200kA 200kA 200kA Class J fuses only ➊ Class J fuses only ➊ Class J fuses only ➊ –4°…+130°F (–20°…+55°C) –4°…+130°F (–20°…+55°C) –4°…+130°F (–20°…+55°C) Silver, Ag Silver, Ag Silver, Ag Typical Class J (1-30A) Fuse Dimensions ➊ SSNA9000 Wire Strip Length M ® 600V AC/DC Maximum Current Wire Range (Rated Cross Section) ® ➊Fuses not offered by Sprecher + Schuh. ➋FH8 UL File E196851, CSA 236535 M40 Discount Schedule B-7 Series FH8 Fuse Holders For Class J Fuses, 60A DIN-rail Mounted Fuse Holders – Class J Fuses, 60A ➊➋ 3.23" (82mm) 3.23" (82mm) 1.57" (40mm) FH8-1PJ60 FH8-1PJ60-L 43 49 6 6 3.23" (82mm) 3.15" (80mm) Price Ea. Pkg (Std Pkg) Qty Catalog Number Catalog Number 4.65" (118mm) Ordering and Technical Information Fuse Holder Without Blown Fuse LED With Blown Fuse LED Three Pole 4.65" (118mm) Two Pole 4.65" (118mm) One Pole 4.72" (120mm) Price Ea. Pkg (Std Pkg) Qty Catalog Number FH8-2PJ60 FH8-2PJ60-L Price Ea. Pkg (Std Pkg) Qty 89 101 3 3 FH8-3PJ60 FH8-3PJ60-L 134 152 2 2 See page A58 12 12 3F 3AF See page A58 12 12 See Section N 50 10 V7-EA35 V7-EAH35 See Section N 50 10 Accessories DIN-rail Top Hat, low profile (priced per rail) Top Hat, high profile (priced per rail) 3F 3AF End Anchors DIN Rail — Normal Duty DIN Rail — Heavy Duty V7-EA35 V7-EAH35 See page A58 12 12 3F 3AF See Section N 50 10 V7-EA35 V7-EAH35 Fuse Block Specifications Approvals Voltage Rating ® 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 60 A 60 A 60 A 60 A 60 A 60 A #10–#1 AWG Cu 6…50mm2 #10–#1 AWG Cu 6…50mm2 #10–#1 AWG Cu 6…50mm2 #10–#1 AWG Cu 6…50mm2 #10–#1 AWG Cu 6…50mm2 #10–#1 AWG Cu 6…50mm2 600V AC/DC 0.8" (20 mm) 0.8" (20 mm) 0.8" (20 mm) Recommended Tightening Torque 31...35 lb-in. (3.5...4 Nm) 31...35 lb-in. (3.5...4 Nm) 31...35 lb-in. (3.5...4 Nm) Working Voltage (indicating circuit) 110…600V AC/DC 110…600V AC/DC 110…600V AC/DC Leakage Current (indicating circuit) 2.0 mA 2.0 mA 2.0 mA Withstand Rating 200kA 200kA 200kA Fuse Type Operating Temperature Contact Material Common Class J Applications • Motor circuits • Feeders and mains • Branch circuit protection • Lighting, heating and general loads • Power transformers • Control transformers • Control circuits Class J fuses only ➊ Class J fuses only ➊ Class J fuses only ➊ –4°…+130°F (–20°…+55°C) –4°…+130°F (–20°…+55°C) –4°…+130°F (–20°…+55°C) Silver, Ag Silver, Ag Silver, Ag Typical Class J (31-60A) Fuse Dimensions ➊ M Circuit Protection Wire Strip Length ➊Fuses not offered by Sprecher + Schuh. ➋FH8 UL File E196851, CSA 236535 FH8 SSNA9000 ® 600V AC/DC Maximum Current Wire Range (Rated Cross Section) ® Discount Schedule B-7 M41 Fuse Block Selection Guide Series FH8 Fuse Holders Control Transformers - Primary ➊ Transformer VA 50 100 150 200 250 300 500 1000 1500 2000 3000 5000 7500 10000 Max. Fuse Value Block 208V 1.125 2.25 3.5 4.5 6.0 7.0 6.0 12.0 17.5 20.0 35.0 60.0 ~ ~ 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 60A 60A ~ ~ Max. Fuse Value Block 240V 1.0 2.0 3.0 4.0 5.0 6.25 5.0 10.0 15.0 20.0 30.0 50.0 ~ ~ 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 60A 60A ~ ~ Max. Value Fuse Block 480 0.5 1.0 1.5 2.0 2.5 3.0 5.0 5.0 7.5 10.0 15.0 25.0 35.0 50.0 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 60A 60A Max. Fuse Value Block 575V 0.4 0.6 1.25 1.6 2.0 2.5 4.0 8.0 6.25 8.0 12.0 20.0 30.0 40.0 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 60A 60A Control Transformers - Secondary Transformer Max. Value VA Fuse Block 24V 50 100 150 200 250 300 500 1000 1500 2000 3000 5000 7500 10000 3.2 6.25 10.0 12.0 15.0 20.0 30.0 60.0 ~ ~ ~ ~ ~ ~ 30A 30A 30A 30A 30A 30A 30A 60A ~ ~ ~ ~ ~ ~ Max. Fuse Value Block 120V 0.6 1.25 2.0 2.5 3.2 4.0 6.25 12.0 17.5 25.0 35.0 60.0 ~ ~ 30A 30A 30A 30A 30A 30A 30A 30A 30A 30A 60A 60A ~ ~ The Maximum Values listed in the tables are calculated from the following procedures, which can be found in the NEC . Always compute the Max. Value for your specific application prior to selecting a fuse block. Calculating NEC Maximum Values Selecting the proper fuse block current ratings for the primary and secondary protection of control transformers (per UL/NEC) is as follows: Primary Overcurrent Protection for Control Transformers Control Circuits: If the rated primary current is less than 2 amps, the maximum rating of the overcurrent device is 500%. If the rated primary current is more than 2 amps, the maximum rating of the overcurrent device is 250%. Secondary Overcurrent Protection for Control Transformers Control Circuits: If the rated secondary current is less than 9 amps, the maximum rating of the overcurrent device is 167%. If 9 amps or more, the maximum rating of the overcurrent device is 125%. The next larger size of an overcurrent device may be used if 125% does not correspond to a standard size. Reference: UL 508 19.3, NEC 430-72(c) exception No. 2, 450-3(b) 1 & 2 Primary Fuse Block Selection Example: 1000VA Transformer 480V Primary 1000/480 = 2.08 Amps [May increase by 250% if above 2A] 2.08 x 250% = 5.21 Amps Select 30A FH8 Class CC fuse block for 5A Class CC Fuse SSNA9000 Secondary Fuse Block Selection Example: 5000VA Transformer 120V Secondary 5000/120 = 41.7 Amps [May increase by 125% if above 9A] 41.7 x 125% = 52.1 Amps Select 60A FH8 Class J fuse block for 50A Class J Fuse Circuit Protection M FH8 ➊Class CC and Class J fuses may be used for Primary Protection, contact fuse manufacturer for specific use. M42 Discount Schedule B-7 Fuse Block Selection Guide Series FH8 Fuse Holders Three Phase Motor Loads ➊➋➌ Horsepower FLA Fuse Block FLA 208V Fuse Block FLA 240V Fuse Block FLA 480V Fuse Block 575V 1/2 2.4 30A 2.2 30A 1.1 30A 0.9 30A 3/4 3.5 30A 3.2 30A 1.6 30A 1.3 30A 1 4.6 30A 4.2 30A 2.1 30A 1.7 30A 1-1/2 6.6 30A 6.0 30A 3.0 30A 2.4 30A 2 7.5 30A 6.8 30A 3.4 30A 2.7 30A 3 10.6 30A 9.6 30A 4.8 30A 3.9 30A 5 16.8 30A 15.2 30A 7.6 30A 6.1 30A 7-1/2 24.2 60A 22.0 60A 11.0 30A 9.0 30A 10 30.8 60A 28.0 60A 14.0 30A 11.0 30A 15 ~ ~ 42.0 60A 21.0 30A 17.0 30A 20 ~ ~ ~ ~ 27 60A 22.0 60A 25 ~ ~ ~ ~ 34 60A 27.0 60A 30 ~ ~ ~ ~ 40 60A 32.0 60A 40 ~ ~ ~ ~ ~ ~ 41.0 60A Single Phase Motor Loads ➊➋➌ Horsepower Fuse Block FLA FLA 115V Fuse Block 230V 1/6 4.4 30A 2.2 30A 1/4 5.8 30A 2.9 30A 1/3 7.2 30A 3.6 30A 1/2 9.8 30A 4.9 30A 3/4 13.8 30A 6.9 30A 1 16 30A 8 30A 1-1/2 20 30A 10 30A 2 24 60A 12 30A 3 34 60A 17 30A 5 ~ ~ 28 60A 7-1/2 ~ ~ 40 60A 10 ~ ~ 50 60A Circuit Protection ➊Fuse block size is based on Class J Type time-delay fuses for typical motor acceleration up to 5 seconds. Limited use of Class CC fuse blocks may be used for motor loads, contact fuse manufacturer for acceptance. ➋FLA Data is in accordance with UL-508 Table 42.2 & NEC Tables 430-148 & 150. ➌Selection of fuse block should be based on selected fuse manufacturer data. Discount Schedule B-7 FH8 SSNA9000 M M43 Series FH8 Fuse Holders Notes FH8 SSNA9000 Circuit Protection M M44 Discount Schedule B-7