Reflex Sensors for Measuring Tasks
Transcription
Reflex Sensors for Measuring Tasks
280 Reflex Sensors for Measuring Tasks The Sensors measure the distance between the Sensor and the object. They work with laser light (red), red light or infrared light after the triangulation principle. For this reason, the object’s color, shape and surface characteristics have practically no influence on measurement results. A voltage within a range of 0 … 10 V DC is made available so an analog output or as current value from 4 … 20 mA. Applications •• •• •• •• •• •• •• High precision positioning Thickness, height and distance measurements Static and dynamic differential measurements Diameter monitoring Vibration measurement Contour measurement Monitoring of two-layer materials 281 CP08/CP24/CP35/OCP801/OCP162/OCP352 The output signal of the diffuse light Sensor with CMOS line array technology is practically independent of brightness, color and surface characteristics of the object to be measured. The measured value can be read out as a voltage value within a range of 0 … 10 V, as a current value within a range of 4 … 20 mA, or in digital format via the RS-232 interface. A rising or falling characteristic curve can be selected. Optionally high speed (Speed-Mode) or high resolution (Resolution-Mode) can be selected. Teach-In, filter functions, error outputs and a RS-232 interface are available. The measuring range can be selected individually within the Sensor’s working range. A precise error message is generated if the measuring range is exceeded, or in the event of non- measurable surfaces or system errors. HT_MGV80 Laser Class These Sensors are equipped with an analog output, as well as a switching output. ON and OFF points can be adjusted with the help of two potentiometers. The devices are thus especially well suited for Go/No-Go applications. The Sensors function in accordance with the principle of triple beam correction, rules out edge effects and angle error independent of mounting position. Sensors with laser class 1 have the smallest laser capacity according to EN 60825-1 and make warning signs redundant. Due to their higher light capacity Sensors with laser class 2 achieve better specifications. Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com 282 Reflex Sensors for Measuring Tasks 43...53 mm Working Range LASER Technical Data Optical Data Working Range 43...53 mm Measuring Distance 48 mm Measuring Range 10 mm Linearity 0,5 % Light Source Laser (red) Wave Length 660 nm Service Life (T = +25 °C) 100000 h Laser Class (EN 60825-1) 2 max. Ambient Light 10000 Lux Light Spot Diameter 0,5 mm Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 30 mA Temperature Drift (Tu < 10 °C, Tu > 40 °C) 5 µm/K Temperature Drift (10 °C < Tu < 40 °C) 5 µm/K Temperature Range -10...60 °C Error Output Voltage Drop < 2,5 V PNP Error Output/Switching Current 200 mA Analog Output 0...10 V Short Circuit Protection yes Reverse Polarity Protection yes Cut-Off Frequency up to 1 kHz Overload Protection yes Protection Class III Linearity: 0,5 % Mechanical Data Measuring Range: 10 mm Housing Plastic Full Encapsulation yes Resolution up to 2 µm Degree of Protection IP67 Connection M12 × 1 These sensors are equipped with an analog output and can thus be utilized for measuring tasks. The output signal is practically independent of the object´s color. High resolution and a wide variety of measuring ranges allow for use in innumerable applications. 1 = Transmitter Diode 2 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 283 YP05MGVL80 < 20 µm < 4 µm Cut-Off Frequency 1 kHz 100 Hz Response Time 500 µs 5 ms Connection Diagram No. 503 503 Control Panel No. P3 P3 Part Number YP05MGV80 Plug Version Error Output Analog Output Resolution Suiting Connection Technology No. Suiting Mounting Technology No. 80 380 80 380 Connection Diagrams page 952 / System Components page 828 Complimentary Products Analog Evaluation Unit AW02 Protection Housing Set ZSP-NN-02 Protection Housing ZSV-0x-01 Error of Measurement Typical characteristic curve based on Kodak white, 90 % YP05MGV80 Ctrl.Panel 03 12 dSr/mm P3 0.3 0.2 0.1 0.0 -0.1 -0.2 -0.3 -0.4 43 44 45 46 47 48 49 50 51 52 53 Sr/mm 03 = Error Indicator 12 = Analog Output Indicator Sr = Switching Distance black 6 % dSr = Switching Distance Change Aluminum Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com 284 Reflex Sensors for Measuring Tasks 40...60 mm Working Range LASER Technical Data Optical Data Working Range 40...60 mm Measuring Distance 50 mm Measuring Range 20 mm Linearity 0,5 % Light Source Laser (red) Wave Length 660 nm Service Life (T = +25 °C) 100000 h Laser Class (EN 60825-1) 2 max. Ambient Light 10000 Lux Light Spot Diameter 0,5 mm Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 30 mA Temperature Drift (Tu < 10 °C, Tu > 40 °C) 10 µm/K Temperature Drift (10 °C < Tu < 40 °C) 7 µm/K Temperature Range -10...60 °C Error Output Voltage Drop < 2,5 V PNP Error Output/Switching Current 200 mA Analog Output 0...10 V Short Circuit Protection yes Reverse Polarity Protection yes Cut-Off Frequency up to 1 kHz Overload Protection yes Protection Class III Linearity: 0,5 % Mechanical Data Measuring Range: 20 mm Housing Plastic Full Encapsulation yes Resolution up to 5 µm Degree of Protection IP67 Connection M12 × 1 These sensors are equipped with an analog output and can thus be utilized for measuring tasks. The output signal is practically independent of the object´s color. High resolution and a wide variety of measuring ranges allow for use in innumerable applications. 1 = Transmitter Diode 2 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 285 YP06MGVL80 < 40 µm < 10 µm Cut-Off Frequency 1 kHz 100 Hz Response Time 500 µs 5 ms Connection Diagram No. 503 503 Control Panel No. P3 P3 Part Number YP06MGV80 Plug Version Error Output Analog Output Resolution Suiting Connection Technology No. Suiting Mounting Technology No. 80 380 80 380 Connection Diagrams page 952 / System Components page 828 Complimentary Products Analog Evaluation Unit AW02 Protection Housing Set ZSP-NN-02 Protection Housing ZSV-0x-01 Error of Measurement Typical characteristic curve based on Kodak white, 90 % YP06MGV80 Ctrl.Panel dSr/mm P3 0.2 0.0 -0.2 03 12 -0.4 -0.6 -0.8 -1.0 -1.2 -1.4 40 42 44 46 48 50 52 54 56 58 60 Sr/mm 03 = Error Indicator 12 = Analog Output Indicator Sr = Switching Distance black 6 % dSr = Switching Distance Change Aluminum Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com 286 Reflex Sensors for Measuring Tasks 30...80 mm Working Range LASER Technical Data Optical Data Working Range 30...80 mm Measuring Range 50 mm Resolution < 8 µm Resolution (Speed-Mode) < 12 µm Linearity 0,1 % Linearity (Speed-Mode) 0,2 % Light Source Laser (red) Wave Length 660 nm Service Life (T = +25 °C) 100000 h max. Ambient Light 10000 Lux Light Spot Diameter see Table 1 Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 80 mA Temperature Drift < 5 µm/K Temperature Range -25...50 °C Analog Output 0...10 V Current Load Voltage Output < 1 mA Analog Output 4...20 mA Current Output Load Resistance < 500 Ohm Interface RS-232 High resolution 8 µm (Resolution-Mode) Baud Rate 38400 Bd Protection Class III Linearity 0,1 % (Resolution-Mode) Mechanical Data Response Time < 660 µs (Speed-Mode) Adjustment Teach-In Housing Plastic Zoom function Degree of Protection IP67 Connection M12 × 1 The sensor uses a high-resolution CMOS line array and DSP technology, virtually eliminating material, colour and brightness related measurement value differences. The Measurement range is calibrated accurate to 10µm. Integrated analogue output can be configured for voltage 0...10 V (10...0 V) or current 4...20 mA (20...4 mA). 1 = Transmitter Diode 2 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 287 OCP801H0180 Part Number CP08MHT80 Plug Version Error Output Analog Output RS-232 Interface Laser Class (EN 60825-1) Measurement Rate Measurement Rate (Resolution-Mode) 2 1 1500 /s 1000 /s 600 /s 500 /s Response Time < 660 µs < 1000 µs Response Time (Resolution Mode) < 1660 µs < 2000 µs Connection Diagram No. 529 529 Control Panel No. P7 P7 Suiting Connection Technology No. 80 Suiting Mounting Technology No. 380 80 380 Connection Diagrams page 952 / System Components page 828 Complimentary Products Analog Evaluation Unit AW02 Interface Cable S232W3 Protection Housing Set ZSP-NN-02 Protection Housing ZSV-0x-01 Table 1 Working Distance Light Spot Size 30 mm 80 mm 0,5 × 1 mm 1 × 2 mm Output Graph Ctrl.Panel 10 25 63 12 03 24 a U/V P7 5.0 07 c 0.0 03 = Error Indicator 25 = Minus Button 07 = Selector Switch 63 = Analog Output Current Indicator 12 = Analog Output Indicator 24 = Plus Button 0 c = Measuring Range a = Analog Voltage Output Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com 288 Reflex Sensors for Measuring Tasks 50...100 mm Working Range LASER Technical Data Optical Data Working Range 50...100 mm Measuring Distance 75 mm Measuring Range 50 mm Linearity 0,5 % Light Source Laser (red) Wave Length 660 nm Service Life (T = +25 °C) 100000 h Laser Class (EN 60825-1) 2 max. Ambient Light 10000 Lux Light Spot Diameter 1 mm Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 30 mA Temperature Drift (Tu < 10 °C, Tu > 40 °C) 20 µm/K Temperature Drift (10 °C < Tu < 40 °C) 10 µm/K Temperature Range -10...60 °C Error Output Voltage Drop < 2,5 V PNP Error Output/Switching Current 200 mA Analog Output 0...10 V Short Circuit Protection yes Reverse Polarity Protection yes Cut-Off Frequency up to 1 kHz Overload Protection yes Protection Class III Linearity: 0,5 % Mechanical Data Measuring Range: 50 mm Housing Plastic Full Encapsulation yes Resolution up to 20 µm Degree of Protection IP67 Connection M12 × 1 These sensors are equipped with an analog output and can thus be utilized for measuring tasks. The output signal is practically independent of the object´s color. High resolution and a wide variety of measuring ranges allow for use in innumerable applications. 1 = Transmitter Diode 2 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 289 YP11MGVL80 < 100 µm < 25 µm Cut-Off Frequency 1 kHz 100 Hz Response Time 500 µs 5 ms Connection Diagram No. 503 503 Control Panel No. P3 P3 Part Number YP11MGV80 Plug Version Error Output Analog Output Resolution Suiting Connection Technology No. Suiting Mounting Technology No. 80 380 80 380 Connection Diagrams page 952 / System Components page 828 Complimentary Products Analog Evaluation Unit AW02 Protection Housing Set ZSP-NN-02 Protection Housing ZSV-0x-01 Error of Measurement Typical characteristic curve based on Kodak white, 90 % YP11MGV80 Ctrl.Panel 03 12 dSr/mm P3 3.0 2.5 2.0 1.5 1.0 0.5 0.0 -0.5 50 55 60 65 70 75 80 85 90 95 Sr/mm 03 = Error Indicator 12 = Analog Output Indicator Sr = Switching Distance black 6 % dSr = Switching Distance Change Aluminum Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com 290 Reflex Sensors for Measuring Tasks 40...160 mm Working Range LASER Technical Data Optical Data Working Range 40...160 mm Measuring Range 120 mm Resolution < 20 µm Resolution (Speed-Mode) < 30 µm Linearity 0,1 % Linearity (Speed-Mode) 0,2 % Light Source Laser (red) Wave Length 660 nm Service Life (T = +25 °C) 100000 h max. Ambient Light 10000 Lux Light Spot Diameter see Table 1 Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 80 mA Temperature Drift < 10 µm/K Temperature Range -25...50 °C Analog Output 0...10 V Current Load Voltage Output < 1 mA Analog Output 4...20 mA Current Output Load Resistance < 500 Ohm Interface RS-232 High resolution 20 µm (Resolution-Mode) Baud Rate 38400 Bd Protection Class III Linearity 0,1 % (Resolution-Mode) Mechanical Data Response Time < 660 µs (Speed-Mode) Adjustment Teach-In Housing Plastic Zoom function Degree of Protection IP67 Connection M12 × 1 The sensor uses a high-resolution CMOS line array and DSP technology, virtually eliminating material, colour and brightness related measurement value differences. The Measurement range is calibrated accurate to 10µm. Integrated analogue output can be configured for voltage 0...10 V (10...0 V) or current 4...20 mA (20...4 mA). 1 = Transmitter Diode 2 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 291 OCP162H0180 Part Number CP24MHT80 Plug Version Error Output Analog Output RS-232 Interface Laser Class (EN 60825-1) Measurement Rate Measurement Rate (Resolution-Mode) 2 1 1500 /s 1000 /s 600 /s 500 /s Response Time < 660 µs < 1000 µs Response Time (Resolution Mode) < 1660 µs < 2000 µs Connection Diagram No. 529 529 Control Panel No. P7 P7 Suiting Connection Technology No. 80 Suiting Mounting Technology No. 380 80 380 Connection Diagrams page 952 / System Components page 828 Complimentary Products Analog Evaluation Unit AW02 Interface Cable S232W3 Protection Housing Set ZSP-NN-02 Protection Housing ZSV-0x-01 Table 1 Working Distance Light Spot Size 40 mm 160 mm 0,5 × 1,2 mm 1 × 2,5 mm Output Graph Ctrl.Panel 10 25 63 12 03 24 a U/V P7 5.0 07 c 0.0 03 = Error Indicator 25 = Minus Button 07 = Selector Switch 63 = Analog Output Current Indicator 12 = Analog Output Indicator 24 = Plus Button 0 c = Measuring Range a = Analog Voltage Output Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com Reflex Sensors 292 for Measuring Tasks 150...250 mm Working Range LASER Technical Data Optical Data Working Range 150...250 mm Measuring Distance 200 mm Measuring Range 100 mm Resolution 200 µm Linearity 1% Light Source Laser (red) Wave Length 660 nm Service Life (T = +25 °C) 100000 h Laser Class (EN 60825-1) 2 max. Ambient Light 10000 Lux Light Spot Diameter 1 mm at a Distance of 200 mm Focus Distance 100 mm Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 25 mA Cut-Off Frequency 250 Hz Response Time 2 ms Temperature Drift 50 µm/K Temperature Range -10...60 °C Error Output Voltage Drop < 2,5 V Analog Output: 0...10 V DC Analog Output 0...10 V Short Circuit Protection yes Error Output Reverse Polarity Protection yes Linearity: 1 % Overload Protection yes Protection Class III Triple Beam Correction Principle Mechanical Data Housing Plastic Degree of Protection IP67 Connection M12 × 1 These sensors are equipped with an analog output and can thus be utilized for measuring tasks. The output signal is practically independent of the object´s color. High resolution and a wide variety of measuring ranges allow for use in innumerable applications. 1 = Receiver Diode 2 = Transmitter Diode 3 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 293 YT25MGV80 Part Number Plug Version Error Output Analog Output Connection Diagram No. 503 Control Panel No. T3 Suiting Connection Technology No. Suiting Mounting Technology No. 80 330 Connection Diagrams page 952 / System Components page 828 Complimentary Products Analog Evaluation Unit AW02 Error of Measurement Typical characteristic curve based on Kodak white, 90 % YT25MGV80 Ctrl.Panel 12 03 dSr/mm T3 5 0 -5 -10 -15 wenglor sensoric gmbh Narzissenstr. 3 D-88069 Tettnang TEL 07542/5399-0 FAX 07542/5399-988 -20 150 160 170 180 190 200 210 220 230 240 250 Sr/mm 03 = Error Indicator 12 = Analog Output Indicator Sr = Switching Distance black 6 % dSr = Switching Distance Change Aluminum Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com 294 Reflex Sensors for Measuring Tasks 50...350 mm Working Range LASER Technical Data Optical Data Working Range 50...350 mm Measuring Range 300 mm Resolution < 50 µm Resolution (Speed-Mode) < 80 µm Linearity 0,15 % Linearity (Speed-Mode) 0,2 % Light Source Laser (red) Wave Length 660 nm Service Life (T = +25 °C) 100000 h max. Ambient Light 10000 Lux Light Spot Diameter see Table 1 Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 80 mA Temperature Drift < 25 µm/K Temperature Range -25...50 °C Analog Output 0...10 V Current Load Voltage Output < 1 mA Analog Output 4...20 mA Current Output Load Resistance < 500 Ohm Interface RS-232 High resolution 50 µm (Resolution-Mode) Baud Rate 38400 Bd Protection Class III Linearity 0,15 % (Resolution-Mode) Mechanical Data Response Time < 1250 µs (Speed-Mode) Adjustment Teach-In Housing Plastic Zoom function Degree of Protection IP67 Connection M12 × 1 The sensor uses a high-resolution CMOS line array and DSP technology, virtually eliminating material, colour and brightness related measurement value differences. The Measurement range is calibrated accurate to 10µm. Integrated analogue output can be configured for voltage 0...10 V (10...0 V) or current 4...20 mA (20...4 mA). 1 = Transmitter Diode 2 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 295 OCP352H0180 Part Number CP35MHT80 Plug Version Error Output Analog Output RS-232 Interface Laser Class (EN 60825-1) Measurement Rate Measurement Rate (Resolution-Mode) 2 1 800 /s 500 /s 400 /s 250 /s Response Time < 1250 µs < 2000 µs Response Time (Resolution Mode) < 2500 µs < 4000 µs Connection Diagram No. 529 529 Control Panel No. P7 P7 Suiting Connection Technology No. 80 Suiting Mounting Technology No. 380 80 380 Connection Diagrams page 952 / System Components page 828 Complimentary Products Analog Evaluation Unit AW02 Interface Cable S232W3 Protection Housing Set ZSP-NN-02 Protection Housing ZSV-0x-01 Table 1 Working Distance Light Spot Size 50 mm 350 mm 0,6 × 1,5 mm 1,5 × 4 mm Output Graph Ctrl.Panel 10 25 63 12 03 24 a U/V P7 5.0 07 c 0.0 03 = Error Indicator 25 = Minus Button 07 = Selector Switch 63 = Analog Output Current Indicator 12 = Analog Output Indicator 24 = Plus Button 0 c = Measuring Range a = Analog Voltage Output Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com Reflex Sensors 296 for Measuring Tasks 35...85 mm Working Range Technical Data Optical Data Working Range 35...85 mm Measuring Distance 60 mm Measuring Range 50 mm Resolution 500 µm Linearity <2% Light Source Red Light Wave Length 660 nm Service Life (T = +25 °C) 100000 h max. Ambient Light 10000 Lux Light Spot Diameter 2 mm Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 40 mA Cut-Off Frequency 100 Hz Response Time 5 ms Temperature Drift 35 µm/K Temperature Range -10...60 °C PNP Error Output/Switching Current 200 mA Analog Output 0...10 V Output Current Analog Output 500 µA Short Circuit Protection yes Analog Output Reverse Polarity Protection yes Protection Class III Error Message Mechanical Data Red Light Housing Stainless Steel Full Encapsulation yes Degree of Protection IP67 Connection Prewired Cable Length 6,1 m These sensors are equipped with an analog output and can thus be utilized for measuring tasks. The output signal is practically independent of the object´s color. High resolution and a wide variety of measuring ranges allow for use in innumerable applications. 1 = Receiver Diode 2 = Transmitter Diode All dimensions in mm (1 mm = 0.03937 Inch) 297 HD09MG-P24 Part Number Prewired Version Analog Output Connection Diagram No. Control Panel No. Suiting Mounting Technology No. 613 D13 150 160 Connection Diagrams page 952 / System Components page 828 Complimentary Products Analog Evaluation Unit AW02 Dust extraction tube STAUBTUBUS-01 Error of Measurement Typical characteristic curve based on Kodak white, 90 % HD09MG-P24 Ctrl.Panel dSr/mm D13 0,4 0,2 0,0 -0,2 -0,4 79 12 -0,6 -0,8 30 40 50 60 70 80 90 Sr/mm 12 = Analog Output Indicator 79 = Run / Error Indicator Sr = Switching Distance black 6 % dSr = Switching Distance Change grey 18 % Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com Reflex Sensors 298 for Measuring Tasks 55...155 mm Working Range Technical Data Optical Data Working Range 55...155 mm Measuring Distance 105 mm Measuring Range 100 mm Resolution 500 µm Linearity 1% Light Source Red Light Wave Length 660 nm Service Life (T = +25 °C) 100000 h max. Ambient Light 10000 Lux Light Spot Diameter 3 mm Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 40 mA Cut-Off Frequency 100 Hz Response Time 5 ms Temperature Drift 50 µm/K Temperature Range -10...60 °C PNP Error Output/Switching Current 200 mA Analog Output 0...10 V Output Current Analog Output 500 µA Short Circuit Protection yes Analog Output: 0...10 V DC Reverse Polarity Protection yes Protection Class III Error Output Mechanical Data Large Measuring Range Housing Plastic Full Encapsulation yes Red Light Degree of Protection IP67 Connection Prewired Cable Length 6m These sensors are equipped with an analog output and can thus be utilized for measuring tasks. The output signal is practically independent of the object´s color. High resolution and a wide variety of measuring ranges allow for use in innumerable applications. 1 = Transmitter Diode 2 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 299 HN24MGV-P24 Part Number Prewired Version Error Output Analog Output Connection Diagram No. 603 Control Panel No. N2 Suiting Mounting Technology No. 350 Connection Diagrams page 952 / System Components page 828 Complimentary Products Analog Evaluation Unit AW02 Dust extraction tube STAUBTUBUS-03 Protection Housing Set ZSN-NN-02 Error of Measurement Typical characteristic curve based on Kodak white, 90 % HN24MGV-P24 Ctrl.Panel 03 12 dSr/mm N2 1.0 0.5 0.0 -0.5 -1.0 -1.5 50 60 70 80 90 100 110 120 130 140 150 Sr/mm 03 = Error Indicator 12 = Analog Output Indicator Sr = Switching Distance black 6 % dSr = Switching Distance Change grey 18 % Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com Reflex Sensors 300 for Measuring Tasks 300...600 mm Working Range Technical Data Optical Data Working Range 300...600 mm Measuring Distance 450 mm Measuring Range 300 mm Resolution see Table 1 Linearity 1% Switching Hysteresis 20 mm Light Source Red Light Wave Length 660 nm Service Life (T = +25 °C) 100000 h max. Ambient Light 10000 Lux Light Spot Diameter see Table 1 Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 50 mA Cut-Off Frequency 50 Hz Response Time 10 ms Temperature Drift 100 µm/K Temperature Range -10...60 °C Switching Output Voltage Drop < 2,5 V PNP Switching Output/Switching Current 200 mA Error Output Voltage Drop < 2,5 V Digital, Analog and Error Outputs PNP Error Output/Switching Current 200 mA Analog Output 0...10 V Go / No-Go testing possible Output Current Analog Output 500 µA Red Light Short Circuit Protection yes Reverse Polarity Protection yes Triple Beam Correction Principle Overload Protection yes Protection Class III Mechanical Data Housing Plastic Degree of Protection IP67 Connection M12 × 1 These sensors are equipped with an analog output, as well as a digital output. The upper and lower switching points of the digital output can be adjusted with two potentiometers. The digital output is activated when an object is located within the window defined in this way. 1 = Receiver Diode 2 = Transmitter Diode 3 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 301 HT60MGV80 Part Number Plug Version Error Output PNP NO Analog Output Connection Diagram No. 506 Control Panel No. T5 Suiting Connection Technology No. Suiting Mounting Technology No. 80 330 Connection Diagrams page 952 / System Components page 828 Table 1 Working Distance Complimentary Products Analog Evaluation Unit AW02 300 mm 450 mm 600 mm Light Spot Diameter 10 mm 15 mm 20 mm Resolution 0,3 mm 2 mm 5 mm Error of Measurement Typical characteristic curve based on Kodak white, 90 % Ctrl.Panel HT60MGV80 T5 01 33 13 14 dSr/mm 5 0 -5 -10 -15 -20 300 01 = Switching Status Indicator 13 = Upper Potentiometer 14 = Lower Potentiometer 33 = Analog Voltage Output-/ Error Warning 350 400 450 500 550 600 Sr/mm Sr = Switching Distance black 6 % dSr = Switching Distance Change grey 18 % Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com Reflex Sensors 302 for Measuring Tasks 350...850 mm Working Range Technical Data Optical Data Working Range 350...850 mm Measuring Distance 600 mm Measuring Range 500 mm Resolution see Table 1 Linearity 1% Switching Hysteresis 20 mm Light Source Infrared Light Wave Length 880 nm Service Life (T = +25 °C) 100000 h Risk Group (EN 62471) 1 max. Ambient Light 10000 Lux Light Spot Diameter see Table 1 Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 50 mA Cut-Off Frequency 100 Hz Response Time 5 ms Temperature Drift 200 µm/K Temperature Range -10...60 °C Switching Output Voltage Drop < 2,5 V PNP Switching Output/Switching Current 200 mA Digital, Analog and Error Outputs Error Output Voltage Drop < 2,5 V PNP Error Output/Switching Current 200 mA Go / No-Go testing possible Analog Output 0...10 V Infrared Light Output Current Analog Output 500 µA Short Circuit Protection yes Triple Beam Correction Principle Reverse Polarity Protection yes Overload Protection yes Protection Class III Mechanical Data Housing Plastic Degree of Protection IP67 Connection M12 × 1 These sensors are equipped with an analog output, as well as a digital output. The upper and lower switching points of the digital output can be adjusted with two potentiometers. The digital output is activated when an object is located within the window defined in this way. 1 = Receiver Diode 2 = Transmitter Diode 3 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 303 HT66MGV80 Part Number Plug Version Error Output PNP NO Analog Output Connection Diagram No. 506 Control Panel No. T5 Suiting Connection Technology No. Suiting Mounting Technology No. 80 330 Connection Diagrams page 952 / System Components page 828 Table 1 Working Distance Light Spot Diameter Resolution Complimentary Products Analog Evaluation Unit AW02 350 mm 600 mm 850 mm 6 mm 10 mm 20 mm 0,3 mm 3 mm 8 mm Error of Measurement Typical characteristic curve based on Kodak white, 90 % Ctrl.Panel HT66MGV80 T5 01 33 13 14 dSr/mm 5 0 -5 -10 -15 -20 300 01 = Switching Status Indicator 13 = Upper Potentiometer 14 = Lower Potentiometer 33 = Analog Voltage Output-/ Error Warning 400 500 600 700 800 900 Sr/mm Sr = Switching Distance black 6 % dSr = Switching Distance Change grey 18 % Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com Reflex Sensors 304 for Measuring Tasks 300...1300 mm Working Range Technical Data Optical Data Working Range 300...1300 mm Measuring Distance 800 mm Measuring Range 1000 mm Resolution see Table 1 Linearity 2% Switching Hysteresis 50 mm Light Source Infrared Light Wave Length 880 nm Service Life (T = +25 °C) 100000 h Risk Group (EN 62471) 1 max. Ambient Light 10000 Lux Light Spot Diameter see Table 1 Electrical Data Supply Voltage 18...30 V DC Current Consumption (Ub = 24 V) < 50 mA Cut-Off Frequency 50 Hz Response Time 10 ms Temperature Drift 500 µm/K Temperature Range -10...60 °C Switching Output Voltage Drop < 2,5 V PNP Switching Output/Switching Current 200 mA Digital, Analog and Error Outputs Error Output Voltage Drop < 2,5 V PNP Error Output/Switching Current 200 mA Go / No-Go testing possible Analog Output 0...10 V Infrared Light Output Current Analog Output 500 µA Short Circuit Protection yes Triple Beam Correction Principle Reverse Polarity Protection yes Overload Protection yes Protection Class III Mechanical Data Housing Plastic Degree of Protection IP67 Connection M12 × 1 These sensors are equipped with an analog output, as well as a digital output. The upper and lower switching points of the digital output can be adjusted with two potentiometers. The digital output is activated when an object is located within the window defined in this way. 1 = Receiver Diode 2 = Transmitter Diode 3 = Receiver Diode All dimensions in mm (1 mm = 0.03937 Inch) 305 HT77MGV80 Part Number Plug Version Error Output PNP NO Analog Output Connection Diagram No. 506 Control Panel No. T5 Suiting Connection Technology No. Suiting Mounting Technology No. 80 330 Connection Diagrams page 952 / System Components page 828 Table 1 Working Distance Light Spot Diameter Resolution Complimentary Products Analog Evaluation Unit AW02 300 mm 800 mm 1300 mm 6 mm 18 mm 30 mm 0,2 mm 8 mm 30 mm Error of Measurement Typical characteristic curve based on Kodak white, 90 % Ctrl.Panel HT77MGV80 T5 01 33 13 dSr/mm 50 40 30 20 14 10 0 -10 300 01 = Switching Status Indicator 13 = Upper Potentiometer 14 = Lower Potentiometer 33 = Analog Voltage Output-/ Error Warning 400 500 600 700 800 900 1000 1100 1200 1300 Sr/mm Sr = Switching Distance black 6 % dSr = Switching Distance Change grey 18 % Sensors for your success www.wenglor.com Sensors for your success www.wenglor.com