Yarway 5300 Automatic Recirculation Brochure
Transcription
Yarway 5300 Automatic Recirculation Brochure
Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection The 5300 Series Automatic Recirculation Control ARC® valve performs four separate functions within the pumping circuit, all within one compact body. Features • Saves Power Costs - Eliminates the need for continuous recirculation to cool the pump. • Saves System Engineering Time - Includes reverse flow prevention, low flow detection, recirculation flow control, and recirculation flow pressure reduction. - Eliminates multiple vendor complexities associated with systems combining various pneumatic, thermal and mechanical components. • Saves Installation and Maintenance Costs - Needs no electrical wiring, plant or instrument air. - Eliminates other components of a conventional system. - Eliminates multiple pressure reducing orifices and capillary tubes. - Eliminates duplication created by two control valves in a series – one for pressure reduction and one for tight shut-off. • Reduces Downtime - Minimizes the problems of high velocity wiredrawing and cavitation erosion common to high pressure drop service. Sizes • 3" to 12" main discharge feed. • 1" to 3" recirculation discharge. • Flanged or Butt Welding end connections. Pressures • Classes 600, 900, 1500, 2500. Temperature Limitations • 500°F www.pentair.com/valves Copyright © 2013 Pentair. All rights reserved. YAWMC-0489-US-0908 Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection Piston positions bypass control valve. Check Valve Bypass Control Valve prevents reverse flow and detects low flow. permits passage of limited cooling water flow through pump during low load. Discharge Nozzle provides back pressure for fluid condition control. Bypass Flow Ports provide passage for minimum cooling flow to bypass control valve. Lever triggers pilot valve. Flutes reduce pressure by redirecting flow. Cascade Piston dissipates energy of high pressure discharge. Pilot Valve activates cascade element. Copyright © 2013 Pentair. All rights reserved. YAWMC-0489 2 Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection Automatic Recirculation Control Valve During critical low load periods, centrifugal feed pumps need a reliable recirculation system to prevent pump instability and overheating. Because many such systems are constructed of a number of components, the systems can become both complex and costly, requiring substantial outlays for design, installation and maintenance. Yarway’s 5300 ARC® valve, on the other hand, is a complete system within itself. It actually performs four separate functions within the pumping circuit – all within one compact body. Essentially, the 5300 ARC® valve is a check valve installed in the main line. But it also acts as the sensing and powering element which pilots the operation of a recirculation control valve. The sensing system responds to changes in flow rather than pressure. The control valve incorporates a pressure reducing device that divides recirculation flow and guides the resulting streams through successive 90° turns to dissipate the destructive energies of high pressure while controlling fluid velocity. But perhaps even more importantly, the 5300 ARC® valve recirculates only that flow needed to cool a feed pump at critical times of low load rather than permitting a continuous recirculation flow. The valve therefore saves the electrical power that continuous recirculation would consume, which can cost several thousand dollars per year. One Valve – Four Functions Flow sensing that actuates the pilot or the bypass control valve which permits passage of a limited flow of cooling liquid during low load periods. This flow is delivered to the cascade element which dissipates the energy for quiet, safe delivery to the deaerator, condenser or other low pressure sink. Check valve prevents reverse flow through the feed pump. Control Loop System Storage vessel Gate valve (optional) Multiple pressurereducing orifice Four-way air solenoid valve Recirculation control valve FIC To process Gate valve (optional) Gate or control valve Flow meter Check valve Pump Sensing orifice Yarway System Remote back pressure regulator (optional) Storage vessel Check valve To process Bypass element Gate or control valve Automatic recirculation valve Copyright © 2013 Pentair. All rights reserved. Pump YAWMC-0489 3 Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection How it Works the bypass valve is equal to the minimum flow requirement of the pump. The directional changes of the successive helical flutes, as well as the multiple orifices, provide for the absorption of pressure energy. The ARC® valve is installed in the pump discharge line in the position of the main check valve it replaces. It is adaptable to horizontal or vertical piping and to either horizontal or vertical upward flow. Flanged or welded ends are optional to suit specifications. The bypass valve will remain in an open position as long as the pilot valve is open. This corresponds with the position the disc assumes at flow rates between an established low flow and no flow through the main check valve. As the flow rate exceeds the minimum flow rate, the rising disc allows the pilot valve to close; pressure entering the chamber over the piston through the annular clearance around the pilot. Decreasing flow through the valve causes the spring loaded disc to move toward its seat. At a flow rate determined by the minimum flow requirement through the pump, the disc triggers the pilot valve through the lever. This vents the pressure on the head of the piston. Pressure acting on the opposite side of the piston opens the bypass valve, permitting flow through the multi-stage cascade element. The flow rate through Main Flow Normal Main Flow Main Flow Check Valve - Open Pilot Valve - Closed Cascade Valve - Closed * Normal Flow Range - flow rate between maximum pump delivery and required minimum flow rate of pump. Normal Flow Range* Check Valve Bypass Flow Fulcrum Main Flow from Pump Low Main Flow Pilot Valve Cascade Piston Main Flow Check Valve - at Switch Point Pilot Valve - Partially Open Cascade Valve - Opening Check Valve Bypass Flow Fulcrum Main Flow from Pump Low Main Flow Pilot Valve Cascade Piston Main Flow Check Valve - Closed Pilot Valve - Open Cascade Valve - Open Check Valve Bypass Flow Fulcrum Main Flow from Pump Copyright © 2013 Pentair. All rights reserved. Pilot Valve Cascade Piston YAWMC-0489 4 Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection How it Works Valve Installation (common line to receiver) Piping Installation (separate line to receiver) Receiver vessel Receiver vessel Check valve To process To process Check valve Flow from feed pump 3R Elbow radius equal to 3 times normal pipe size Flow from feed pump 3R Elbow radius equal to 3 times normal pipe size How to Specify Centrifugal pump minimum flow protection shall be provided by a self-contained multi-function valve which requires no external source of power. The valve shall provide the functions of: 1. Spring loaded check valve to prevent pump damage from reverse flow. 2. Flow sensor that will activate bypass valve at the specified minimum flow. 3. Bypass flow control valve, sized to provide the minimum required pump flow. 4. Pressure reducing device to effectively reduce high pump discharge pressures to low receiver tank/sump pressures. Actuation of the bypass valve shall be by direct contact of the switching mechanism to the check valve disc. No levers or linkages shall be utilized. Bypass trim travel shall have a 1:1 proportional ratio with the flow sensing disc travel to provide truly optimum modulated flow control. One piece operating element shall be preferred for maximum reliability. The bypass trim shall also be capable of providing extended bypass control service. Service limitations or manual bypass lines for extended bypass service shall not be acceptable. bypass shall be the vendor’s responsibility to control flashing, cavitation and choked flow conditions both within the trim and at the valve discharge. Sealing surfaces in trim shall be located in an area where it will not be prone to erosion and/or cavitation damage. Valves shall be flow tested by the manufacturer, and certified performance curves shall be provided with the valve shipment. The ARC® valve shall be designed and constructed in accordance with ANSI B16.34. Pressure reduction in the Copyright © 2013 Pentair. All rights reserved. YAWMC-0489 5 Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection Series 5300 ARC® Parts and Material Item Part 12 Body 1-A Liner 7 “Size” RFFlange Flange “Size” RF Per ANSI Per ANSIB16.5 B16.5 8 6 6 5 “E” Stage “E” Stage Cascade Cascade 4 “D” RF Flgd ANSI B16.5 C ± 1/16 13 13 10 15 12 12 1 1 B ± 1/32 9 9 2 2 Body Bushing 3 4 51 62 Retaining Ring Liner O-ring Bonnet 7 8 92 10 12 13 Cap Screw Body Bypass Disc Disc Pin Spring 14 Control Head (I/C) 14 Control Head (Bar Stock) Lever Pivot Pin Pilot Valve Pilot Valve Nut Cascade Piston 15 16 171 18 191 3 A ± 1/32 201 Series 5300 ARC® “E” Stage Cascade 1-A 1-A 14 14 22 23 23 22 22 25 25 19 19 21 221 231 241 25 261 271 341 351 361 391 40 20 20 17 17 18 18 16 16 26 26 27 27 34 34 35 35 36 36 39 39 24 24 Copyright © 2013 Pentair. All rights reserved. 40 40 Guide Ring Cascade Seat Bushing Piston Guide Pin (3", 10", 12") O-ring O-ring Guide Pin Cap Screw Seal Ring O-ring Pilot Valve Seat O-ring O-ring O-ring Orifice Material ASTM A-216 Grade WCB AISI 302 Stainless Steel ASTM A276-S21800 (Nitronic 60 Bar) Steel AISI 304 Stainless Steel TFE/Propylene ASTM A-216 Grade WCB ASTM A276-S21800 (Nitronic 60 Bar) ASTM A193 Grade B7 ASTM A-216 Grade WCB ASTM A351 Type CF8M ASME SA564-S63000 COND A ASTM A313-S30200 ASTM A747 Grade CB7Cu-1 (17-4 PH Cast) Condition H900 (J92180) ASME SA564-S63000 COND A ASTM A582-S41600 ASTM A582-S41600 COND T ASTM A276-S43100 AISI 420F ASME SA479 S41000 ASTM A747 Grade CB7Cu-1 (17-4 PH Cast) Condition H900 (J92180) ASME SA564-S63000 COND A TFE/Propylene TFE/Propylene Stainless Steel 18-8 ASTM A193 Grade B7 Turcon T11 (Glyd Ring) TFE/Propylene ASTM A276-S43100 TFE/Propylene TFE/Propylene TFE/Propylene ASME SA479-S31600 Notes: 1. Recommended spare parts. 2. Type 316 SS construction available upon request. YAWMC-0489 6 Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection Series 5300 ARC® Flange Ends A ± 1/ 32 C ± 1/ 32 “D” RF Flange Per ANSI B16.5 B ± 1/ 32 Flanged Ends (Data for 11/2", 2" and 21/2" valves available upon request) *Valve Size in. [DN] 3 3 3 3 4 4 4 4 6 6 6 6 8 8 8 8 10 10 10 10 12 12 12 [75] [75] [75] [75] [100] [100] [100] [100] [150] [150] [150] [150] [200] [200] [200] [200] [250] [250] [250] [250] [300] [300] [300] Class ANSI Figure No. 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500 5302 5304 5306 5308 5302 5304 5306 5308 5302 5304 5306 5308 5302 5304 5306 5308 5302 5304 5306 5308 5302 5304 5306 A 10 1/2 10 1/2 10 1/2 13 15 1/2 15 1/2 15 1/2 18 1/4 17 5/8 17 5/8 17 5/8 22 1/ 2 21 21 21 See 28 1/ 2 28 1/ 2 28 1/ 2 32 1/2 32 7/ 8 32 7/ 8 32 7/ 8 Dimensions, in. [mm] B [266.7] [266.7] [266.7] [330.2] [393.7] [393.7] [393.7] [463.6] [447.7] [447.7] [447.7] [571.5] [533.4] [533.4] [533.4] Note 2 [723.9] [723.9] [723.9] [825.5] [835.0] [835.0] [835.0] 6 [152.4] 6 [152.4] 6 13/16 [173.0] 7 9/16 [192.1] 6 3/4 [171.5] 6 3/4 [171.5] 8 3/16 [208.0] 9 1/16 [230.2] 9 1/4 [235.0] 9 9/16 [242.9] 11 [279.4] 12 [304.8] 11 7/ 8 [301.6] 11 7/ 8 [301.6] 11 7/ 8 [301.6] See Note 2 13 7/16 [341.3] 13 7/16 [341.3] 14 13/16 [376.2] 18 7/16 [468.3] 15 1/ 2 [393.7] 15 1/ 2 [393.7] 17 1/ 8 [435.0] C 17 1/16 [433.4] 17 1/16 [433.4] 19 7/8 [504.8] 21 7/8 [555.6] 19 5/16 [490.5] 19 9/16 [496.9] 24 5/16 [617.5] 26 1/8 [663.6] 25 13/16 [655.6] 26 1/8 [663.6] 30 15/16 [785.8] 32 15/16 [836.6] 33 13/16 [858.8] 33 13/16 [858.8] 3313/16 [858.8] See Note 2 361/ 2 [927.1] 361/ 2 [927.1] 41 3/16 [1046.2] 52 1/16 [1322.4] 40 1/ 4 [1022.4] 40 1/ 4 [1022.4] 48 [1219.2] (D) Bypass Flange Size in. [DN] Weight lb. (kg) Rated Main Flow gpm 1 [25] 1 [25] 1 [25] 1 [25] 11/2 [40] 11/2 [40] 11/2 [40] 11/2 [40] 2 [50] 2 [50] 2 [50] 2 [50] 21/2 [65] 21/2 [65] 21/2 [65] See Note 2 3 [80] 3 [80] 3 [80] 3 [80] 3 [80] 3 [80] 3 [80] 170 (77) 200 (91) See Note 2 See Note 2 300 (136) 340 (154) 525 (238) 560 (254) 680 (308) 740 (336) 1400 (635) 1480 (671) 1180 (535) 1330 (603) 1730 (785) See Note 2 1900 (862) 2000 (907) 3020 (1370) 5000 (2268) 2350 (1066) 2600 (1179) See Note 2 400 400 400 400 750 750 750 750 1600 1600 1600 1600 2800 2800 2800 2800 4200 4200 4200 4200 5500 5500 5500 Notes: 1. 14" and 16" sizes available. 2. Contact your sales representative for more information. Copyright © 2013 Pentair. All rights reserved. YAWMC-0489 7 Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection Series 5300 ARC® Butt Welding Ends A ± 1/ 32 C ± 1/ 32 “D” RF Flange Per ANSI B16.5 B ± 1/ 32 Butt Welding Ends (Data for 11/2", 2" and 21/2" valves available upon request) *Valve Size in. [DN] 3 3 3 3 4 4 4 4 6 6 6 6 8 8 8 8 10 10 10 10 12 12 12 12 [75] [75] [75] [75] [100] [100] [100] [100] [150] [150] [150] [150] [200] [200] [200] [200] [250] [250] [250] [250] [300] [300] [300] [300] Class ANSI Figure No. 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 600 900 1500 2500 5301 5303 5305 5307 5301 5303 5305 5307 5301 5303 5305 5307 5301 5303 5305 5307 5301 5303 5305 5307 5301 5303 5305 5307 A Dimensions, in. [mm] B 101/ 2 [266.7] 101/ 2 [266.7] 101/ 2 [266.7] 13 [330.2] 15 1/ 2 [393.7] 15 1/ 2 [393.7] 15 1/ 2 [393.7] 18 1/ 4 [463.6] 17 5/ 8 [447.7] 17 5/ 8 [447.7] 17 5/ 8 [447.7] 221/2 [571.5] 21 [533.4] 21 [533.4] 21 [533.4] 24 3/4 [628.6] 28 1/ 2 [723.9] 28 1/ 2 [723.9] 28 1/ 2 [723.9] 32 1/ 2 [825.5] 32 7/ 8 [835.0] 32 7/ 8 [835.0] 32 7/ 8 [835.0] 42 [1066.8] 6 6 61/ 8 61/ 8 61/ 2 61/ 2 8 3/16 8 3/16 9 3/ 4 9 3/ 4 11 10 3/ 4 12 7/ 8 12 7/ 8 12 7/ 8 13 5/16 14 5/16 14 5/16 1415/16 15 3/16 15 1/2 15 1/2 17 1/ 8 17 1/4 [152.4] [152.4] [155.6] [155.6] [165.1] [165.1] [208.0] [208.0] [247.6] [247.6] [279.4] [273.0] [327.0] [327.0] [327.0] [338.1] [363.5] [363.5] [363.5] [385.8] [393.7] [393.7] [435.0] [438.2] (D) Bypass Flange Size in. [DN] C 17 1/16 17 1/16 19 19 19 1/16 19 1/16 23 7/ 8 23 7/ 8 26 9/16 26 9/16 3015/16 30 11/16 34 7/ 8 34 7/ 8 34 7/ 8 35 1/ 4 37 3/ 8 37 3/ 8 40 3/16 4013/16 40 1/4 40 1/4 48 48 [433.4] [433.4] [482.6] [482.6] [484.2] [484.2] [606.4] [606.4] [674.7] [674.7] [785.8] [779.5] [885.8] [885.8] [885.8] [895.3] [949.3] [949.3] [1020.8] [1036.6] [1022.4] [1022.4] [1219.2] [1219.2] Notes: 1. 14" and 16" sizes available. 2. Contact your sales representative for more information. Copyright © 2013 Pentair. All rights reserved. YAWMC-0489 8 1 1 1 1 11/2 11/2 11/2 11/2 2 2 2 2 21/2 21/2 21/2 21/2 3 3 3 3 3 3 3 3 [25] [25] [25] [25] [40] [40] [40] [40] [50] [50] [50] [50] [65] [65] [65] [65] [80] [80] [80] [80] [80] [80] [80] [80] Weight lb. [kg] Rated Main Flow gpm 130 (59) 136 (62) See Note 2 See Note 2 275 (125) 285 (129) 450 (204) 470 (213) 600 (272) 640 (290) 1125 (510) 1200 (544) 950 (431) 1025 (465) 1290 (585) 2400 (1089) 1400 (635) 1600 (726) 2150 (975) 4150 (1882) 1570 (712) 1740 (789) See Note 2 See Note 2 400 400 400 400 750 750 750 750 1600 1600 1600 1600 2800 2800 2800 2800 4200 4200 4200 4200 5500 5500 5500 5500 Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection Hydraulic Performance Test Lab Performance – Profiled in Yarway’s Hydraulic Performance Test Lab In our hydraulic performance test laboratory, state-of-the-art data acquisition and computer graphics techniques are called upon for evaluation of the significant performance characteristics of Yarway recirculation control valves. The lab’s equipment makes it possible to test a valve over its complete flow range for factors including: • Total flow through the pump • Disc position • Pressure drop across the main check • Bypass Cv • Bypass ΔP • Valve response to sudden changes in flow • Bypass piston pressure These detailed analyses are the user’s complete assurance that the valve meets performance requirements in all respects and can be supplied with the valve. A certified test curve is shipped with each valve (see page 10 for example). Insist on it, as you would for your pump! Copyright © 2013 Pentair. All rights reserved. YAWMC-0489 9 Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection Certified Test Curve Main DP (PSID) 25.0 20.0 15.0 10.0 5.0 0.0 0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500 0 500 1000 1500 2000 2500 3.00 2.50 Disc Lift (IN) 2.00 1.50 1.00 0.50 0.00 16.0 14.0 Bypass Cv 12.0 10.0 8.0 6.0 4.0 2.0 0.0 Main (GPM) 2500.0 Total Flow (GPM) 2000.0 1500.0 1000.0 500.0 0.0 0 500 1000 1500 2000 2500 Main Flow (GPM) Copyright © 2013 Pentair. All rights reserved. YAWMC-0489 10 Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection How to Order Our sales representatives will help you select the correct valve for your application. Please complete this form before contacting the sales office to help ensure all necessary information is provided. Automatic Recirculating Control (ARC®) Valve Data Sheet Customer: Company: Project: Location: Phone: E-Mail: Qty Required: Delivery Required: Additional Info: Tag(s) ID: Pump Flow Please Complete Flow Requirements Normal -Process- flow: M3/H GPM BPD Maximum -Process- flow: Minimum -Process- flow (optional): (if Minimum Flow is to be considered in sizing) Minimum pump protection flow: Pump Discharge Pressure (Minimum required “Recirculation Flow”) Please Complete Pressure Requirements Pump pressure at Shut-off (zero flow): psi KgF/cm2 bar Kpa Pump pressure at Normal -Process- flow: (if Minimum Flow is to be considered in sizing) Pump pressure at Minimum -Process- flow (optional): (at Minimum required “Recirculation Flow”) Pump pressure at Minimum pump protection flow: (Line pressure at ARC Valve bypass port) ARC Valve Bypass line pressure: Temperature Please Enter Both Temperatures °F Normal temperature at ARC Valve: °C Maximum temperature at ARC Valve: Fluid Liquid: Boiler Feed Water (In this case disregard S.G. and V.P.) Other (Please specify) _________________ Specific Gravity: Vapor Pressure: Orientation of ARC Valve: Desired End Connections: Viscosity: Desired Pressure Class: Desired Body Material: Desired Seal Material (except 2" to 8" 9200 and 9300): Pump Drive Type: Vertical Horizontal Raised Face Flange Ring Type Joint (RTJ) Flat Face Flange Butt Weld Ends Other - Specify in “Comments” 150 300 600 900 1500 2500 A216 Gr. WCB A351 Gr. CF8M A351 Gr. CK3MCuN (6Mo) A995 Gr. CD3MWCuN (Super Duplex) Ethylene Propylene (EPR or EPDM) TFE Propylene (Aflas or Fluoraz) Fluorocarbon Rubber (Viton®) Other - Specify in “Comments” Constant Speed - Motor Driven Variable Speed (VFD) - Motor Driven Variable Speed - Turbine Driven Other - Specify in “Comments” Comments: NACE Materials Required? Certificate of Compliance for Hydro Test Required? Flow Test with Performance Certificate Required? Magnetic Particle Test Required? Customer Inspection Required Prior to Shipment? Radiograph Inspection Required (specify scope)? Certified Material Test Report (Pressure Containing Components only)? Flow tests are generally conducted on all model 5300 and 7100 ARC® valves and one model 9100 or 9200 ARC® valve per sales order line item at no additional cost. Model 9300 ARC® valves and other flow test requirements are upon request and at additional cost. If flange drilling is other than ANSI, please specify in “Comments.” Please include Pump Curve if available. Copyright © 2013 Pentair. All rights reserved. YAWMC-0489 11 Yarway 5300 Series ARC® Valve For Centrifugal Pump Protection Copyright © 2013 Pentair. All rights reserved. YAWMC-0489 12