ReddotSignal Product Brochure
Transcription
ReddotSignal Product Brochure
Every year, many accidents occur all over the world because of safety troubles. Injury and wrongful death expectancy in industry working environment is far high than after-working environment. Since 1990, we kept focusing on people working under hazardous environments, from harbor to mining field, metallurgy plant, tall building, high-way, and off-shore site, etc. Our engineers go to all of above work sites to develop more reliable industry warning & communication products. About us Shanghai Reddot was started in 2010 by a group of young people concentrate on signal lighting designing and manufacturing. The company's first product is Aviation Obstruction Light. After the Obstruction Light found its international market, the company will design more products to meet needs of the market. Our goal Reddot focus on R&D and dedicate to provide state-of-the-art product for our customer. Our advantagep Deep understanding on technologies that our product require Absolutely following rules & regulations in the industry we are serving Our value • • • • Dedication Candor Eager for action Continuous change Contents Regulation 01 03 Introduction ICAO Recommendation And Practice Over Various Applications Low Intensity 05 07 09 11 13 OL10 LED Based Low Intensity Obstruction Light OL32 LED Based Low Intensity Obstruction Light OL100 LED Based Low Intensity Obstruction Light OL200 LED Based Low Intensity Obstruction Light E27 LED lamp for low intensity Obstruction light Medium Intensity 15 17 OM2K LED Based Medium Intensity Aviation Obstruction Light OM2C-D LED Based Medium Intensity Obstruction Light Solar Light 19 21 23 25 27 29 31 33 35 37 39 OLS10 Solar Powered Low Intensity Obstruction Light OLS32 Solar Powered Low Intensity Obstruction Light OM2BS Solar Based Medium Intensity Obstruction Light PL10 Solar Powered Obstruction Light PL10A Solar Powered Obstruction Light PL10D Double Solar powered Aviation obstruction light PL10S Solar powered obstruction light OLIS10-V Solar Based Low Intensity Obstruction Light OLIS32-V Solar Based Low Intensity Obstruction Light OLIS32 Solar Powered Low Intensity Obstruction Light OLIS50 Solar Based Low Intensity Obstruction Light Control Box 41 42 44 45 46 CTR04 Control Panel Indoor Type CTR04A Control Box CTR04B Obstruction Light Control Box CTR04-B20 Obstruction Light Control Box CTR04-AIDO Control box Other 48 50 52 53 OMARK Obstruction Marking Sphere Installation Accessories Installation & Commissioning Accessories for Obstruction Lighting System Warranty Policy 54 Warranty Policy Introduction Aviation Obstruction light is a product to warn aircraft potential danger from above groundlevel structures like tower, smokestack, tall building, etc. In some cases, it’s also called Aircraft Warning Light (AWL). When it comes with controller to realize extra functions like alarm signal sending, flash synchronizing, and auto switch on at night, etc, it can also be called Aircraft Warning Light System (AWLS). Regulations ICAO • ICAO & FAA are two major international authorities that regulate obstruction light industry. • ICAO – International Civil Aviation Organization • FAA – Federal Aviation Authority Some quote from ICAO Annex 14, chap. 6 6.1 The marking and/or lighting of obstacles is intended to reduce hazards to aircraft by indicating the presence of the obstacles. It does not necessarily reduce operating limitations which may be imposed by an obstacle. 6.3.1 The presence of objects which must be lighted, as specified in 6.1, shall be indicated y low-, medium- or high-intensity obstacle lights, or a combination of such lights. 6.3.2 Recommendation.— low-intensity obstacle lights, type A or B, should be used where the objects is a less extensive one and its height above the surrounding ground is less than 45m. 6.3.7 Recommendation.— medium-intensity obstacle light, type A, B or C, should be used where the object is an extensive one or its height above the level of the surrounding ground is greater than 45 m. medium-intensity obstacle lights, Types A and C, should be used alone, whereas medium-intensity obstacle lights, Type B, should be used either alone or in combination with low-intensity obstacle lights, Type B. ICAO Annex 14, chap. 6, Table6-3. Characteristics of obstacle lights Peak intensity (cd) at given Background Luminance Light Type Color Signal type (flash rate) Above Below 50 cd / m2 10 mnm Vertical Beam Spread (c) 32 mnm 32 mnm 10° 40 mnm (b) 400 max 12° (h) Low-intensity, Type A Red (fixed obstacle) Low-intensity, Type B Red (fixed obstacle) Fixed 50-500cd 500cd / m2 / m2 10 mnm N/A Fixed N/A Low-intensity, Type C Yellow (mobile obstacle) Blue (a) Low-intensity, Type D Yellow Follow-me Vehicle N/A Flashing (60-90 fpm) N/A Flashing (60-90 fpm) 40 mnm (b) 400 max Medium-intensity, Type A Medium-intensity, Type B Medium-intensity, Type C White Flashing 20 000 (b) (20-60 fpm) ± 25% 20 000 (b) ± 25% 2 000 (b) ± 25% 3° mnm Red N/A Flashing (20-60 fpm) N/A Fixed N/A 2 000 (b) ± 25% 3° mnm N/A 3° mnm High-intensity, Type A White 200 000 (b) 20 000 (b) Flashing ± 25% (40-60 fpm) ± 25% 2 000 (b) ± 25% 2 000 (b) ± 25% High-intensity, Type B White Flashing 100 000 (b) 20 000 (b) ± 25% (40-60 fpm) ± 25% 2 000 (b) ± 25% 3°-7 Red 10° 200 mnm (b) 200 mnm (b) 12° (i) 400 max 400 ma x 3°-7° © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 01 Applicable FAA Advisory Circulars • AC 150/5345-43E Specification for Obstruction Lighting equipment • AC 70/7460-1 Obstruction Marking and Lighting • AC 150/5345-53 Airport Lighting Equipment Certification Program Some quote from FAA AC 150/5345-43E 1.2 Equipment Classification Type FAA Description L-810 Steady-burning red obstruction light L-856 High in tensity flashing white obstruction light, 40 Flashes Per Minute (FPM) L-857 High intensity flashing white obstruction light, 60 FPM L-864 Flashing red obstruction light, 20-40 FPM L-865 Medium intensity flashing white obstruction light, 40 FPM L-866 Medium intensity flashing white obstruction light, 60 FPM L-885 Flashing red obstruction light, 60 FPM 3.3.5.2.2 Monitoring. Each separate L-864 light unit and each tier of L-810 light units shall be monitored for FLASH/FAIL status. FAIL is defined as outage of any lamp in an L-864 light unit, outage of any one lamp in a tier of L-810 light units, or failure of a flasher (steady on and/or total) for an L-864 light unit. Monitor signals shall be fail safe (i.e., active signals for FLASH and absence of signals for FAIL). There shall be a provision to permit connection to a remote alarm device, (supplied by others or as an option) to indicate FLASH/FAIL status. Some quote from FAA AC 70/7460-1K Chapter 5, 51.b. Double Obstruction Light. A double (L-810) light should be installed when used as a top light, at each end of a row of single obstruction lights, and in areas or locations where the failure of a single unit could because an obstruction to be totally unlighted. Chapter 5, 52. CONTROL DEVICE Red obstruction lights should be operated by a satisfactory control device (e.g., photo cell, timer, etc.) adjusted so the lights will be turned on when the northern sky illuminance reaching a vertical surface falls below a level of 60 foot-candles (645.8 lux) but before reaching a level of 35 foot-candles (367.7 lux). The control device should turn the lights off when the northern sky illuminance rises to a level of not more than 60 foot-candles (645.8 lux). The lights may also remain on continuously. The sensing device should, if practical, face the northern sky in the Northern Hemisphere. (See AC 150/5345-43.) 02 © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com ICAO Recommendation And Practice Over Various Applications Tower Height Night only operation Day and Night Below 45 meters Plan A: 2 low intensity type A or B at the top Plan B: 2 low intensity type B at the top 3 low intensity type B at intermediate level(s) every 45 meters on the periphery of the tower 45 m. up to 105 meters Plan A: 2 low intensity type B at the top 3 low intensity type B at intermediate level(s) every 45 meters on the periphery of the tower. 1 or 2 white medium intensity type A at the top. Plan B: 1 or 2 medium intensity lights type B at the top. 3 low intensity lights type B at intermediate levels at 120° Plan C: medium intensity type A or C, use alone Tall buildings Above 105 meters 1 or 2 medium intensity lights type B at the top. 3 low intensity lights type B at intermediate levels at 120°. Above 150 meters 3 high intensity lights at 120° every 150 meters. Height Night only operation Below 45 meters Low intensity type A or B lights at each edge of building and at regular interval every 45 meters. Above 45 meters Plan A: Low intensity type A or B lights at each edge of building and at regular interval every 45 meters. Intermediate lights every 45 meters. Day and Night Plan B: medium intensity type B lights at each edge of building and at regular interval every 45 meters. Low intensity light at intermediate level, every 45 meters. Wind turbines 1 or 2 white medium intensity type A (white) at the top. 3 medium ntensity type A at intermediate levels. 1 or 2 white medium intensity type A (white) at the top. In case of a building exceeding 900 m. length, additional lights should be installed at the edge of the building. Night only operation Day and Night 1 or 2 medium intensity type B (red) located on the top of the turbine. In case of a group of windmills, additional lights at the circumference of the farm every 450m and synchronized. 1 or 2 medium intensity type A (white) located on the top of the turbine. In case of group of windmills, additional lights at the circumference of the farm every 900m and be synchronized. © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 03 Cranes Height Night only operation Below 45 meters 3 low intensity type A or B lights on the jib, counter jib and crane-top. 45 meters up to 105 meters 3 medium intensity lights type B at the top on the jib, counter jib and crane-top. 3 low intensity lights type B at the intermediate levels. Above 105 meters Chimney 1 or 2 red medium intensity type B on the crane-top. In case of more than one crane additional lights should be installed and synchronized 1 or 2 white medium intensity type A (white) on the crane-top. In case of more than one crane, additional lights should be installed and synchronized. 1 or 2 red medium intensity type A on the crane-top. In case of more than one crane, additional lights should be installed and synchronized. Above 150 meters 3 high intensity lights on the crane top Height Night only operation Below 45 meters 3 up to 4 low intensity type A lights placed 1,5 meters up to 3 meters below the to avoid smokes to hide the lights. 45 meters up to 105 meters 3 up to 4 medium intensity type B lights placed 1.5 meters up to 3 meters below the top. 3 up to 4 low intensity type B lights at intermediate level(s) 45m. 3 up to 4 white medium intensity lights type A placed 1.5 meters up to 3 meters below the top. Above 105 meters 3 up to 4 medium intensity type B (red) placed 1.5 meters up to 3 meters below the top. 3 up to 4 white medium intensity lights type A placed 1.5 meters up to 3 meters below the top. 3 up to 4 white medium intensity lights type A at intermediate levels. 3 up to 4 low intensity type B every 45m. Above 150 meters Transmission lines Day and Night 3 high intensity lights at 120° every 150 meters. Night only operation Tower light 04 Day and Night 2 low intensity type A or B lights at the top of each tower. © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com Day and Night Aviation Obstruction Light Low Intensity • • • • • OL10 OL32 OL100 OL200 E27 Bulb http://www.reddotsignal.com/en/products/aviation/ OL10 LED Based Low Intensity Obstruction Light REDDOT OL10 series is typically a standard LED Obstruction light designed for airway fixed obstacle marking application. It comply with ICAO regulation, low intensity, type A. Working mode is steady burning. OL10 Series Double Light OL10 Series Intensity Compliant with 10cd, steady ICAO : low intensity type A FAA : N/A Double light is integrated by 2 single lights. For making sure there is always a light working atop of the tower. Two optional working patterns can meet different area’s customers. • “Service+Standby”: Only “service light” is working normally. It will auto-transfer to “standby light” in case of “service light” failure • “Service+Service”: Two single lights work simultaneously. Either failure will not affect the other normal working. Features • • • • • • • • Special optical design provides better light distribution LED light source esures long lifetime, maintenance free Low power consumption Shock and vibration resistant Corrosion resistant and UV stable polycarbonate housing Ease of mount, mount accessories available Available both in single and double type 5 years warranty Application • • • • • • • Telecomm tower Radio tower Wind turbine Smoke stacks & chimney Tall building Crane Power transmission line Standard • ICAO Annex 14, 4th Edition, July 2004 • ICAO low intensity type A 05 © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com Specifications LIGHT OUTPUT OL10S(Single) OL10DST①(Double) OL10DSS②(Double) Effective Intensity 10 Candela 10 Candela 10 Candela Vertical Divergence 10 Degree Horizontal 360 Degree LED color Red LED lifespan 100,000 Hours OPERATION Steady burning(default) Flash Pattern POWER SUPPLY Input voltage 110-220VAC, 50/60 Hz;12VDC;24VDC;48VDC Power Consumption 4W 4W 8W MACHANICAL STRUCTURE Lens Polycarbonate,UV Stabilized Body Die-casting Aluminum Water-proof IP65 Weight 0.9KG 3.5KG Dimension 159mmx245mm 340mmx413mmx140mm 340mmx413mmx140mm Mounting Size Threaded 3/4’’ bottom hub 3.5KG -40C˚ ~ +55C˚ Temperature Range Relative Humidity 100% with condensation Wind speed Up to 150mph(240kph) Warranty 5 years Optional Available in flashing pattern(40FPM) Available with built-in photosensor Available with built-in alarm relay contacts ① ST: “Service+Standby” ② SS:”Service+Service” Order codes Series OL10 Single/ AC/ Alarm Voltage Flashing Photosensor Double DC relay R S A F P 12 Pattern(For double light only) D SS D 24 ST 48 110 Pipe diameter range 30-80 mm 220 Light Effective Intensity (candela) For example, OL10SD24R means OL10 single light, DC24V power supply, red steady burning, with alarm relay contacts. Ordering Code: AKU80 Mounting kit for 30-80mm vertical or horizonal pipe Photometric Performance 25 OL10 Data 20 ICAO 10cd minimum requirement 15 10 5 -5˚ 0˚ 5˚ 10˚ 15˚ Vertical Divergence (degrees) 20˚ 0 25˚ Pipe diameter range 60-100 mm Ordering Code: AKU100 Mounting kit for 60-100mm vertical l pipe © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 06 OL32 LED Based Low Intensity Obstruction Light REDDOT OL32 LED Low Intensity Obstruction Light series is a 32.5cd (candela) LED light designed for airway fixed obstacle marking application. It comply with ICAO & FAA regulation. It shares the same mechanical design with OL10, but comes with more LED. OL32 Series Intensity Compliant with 32.5cd, steady ICAO : low intensity type B FAA : L810 DGAC Mexico OL32 series double light Double light is integrated by 2 single lights. For making sure there is always a light working atop of the tower. Two optional working patterns can meet different area’s customers. • “Service+Standby”: Only “service light” is working normally. It will auto-transfer to “standby light” in case of “service light” failure • “Service+Service”: Two single lights work simultaneously. Either failure will not affect the other normal working. Features • Special optical design provides better light distribution • LED light source esures long lifetime, maintenance free • Low power consumption • Shock and vibration resistant • Corrosion resistant and UV stable polycarbonate housing • Ease of mount, mount accessories available • Available both in single and double type • 5 years warranty Application • • • • • • • Telecomm tower Radio tower Wind turbine Smoke stacks & chimney Tall building Crane Power transmission line Standard • • • • • ICAO Annex 14, 4th Edition, July 2004 ICAO low intensity, tpye B FAA AC No. 150/5345-43F, 2006 FAA type L810 DGAC Mexico 07 © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com Specifications LIGHT OUTPUT OL32S(Single) OL32DST①(Double) OL32DSS②(Double) Effective Intensity 32.5 Candela 32.5 Candela 32.5 Candela Vertical Divergence 10 Degree Horizontal 360 Degree LED color Red LED lifespan 100,000 Hours OPERATION Steady burning(default) Flash Pattern POWER SUPPLY Input voltage 110-220VAC, 50/60 Hz;12VDC;24VDC;48VDC Power Consumption 6W 6W 12W MACHANICAL STRUCTURE Lens Polycarbonate,UV Stabilized Body Die-casting Aluminum Water-proof IP65 Weight 0.9KG 3.5KG Dimension 159mmx245mm 340mmx413mmx140mm 340mmx413mmx140mm Mounting Size Threaded 3/4’’ bottom hub Temperature Range 3.5KG -40C˚ ~ +55C˚ Relative Humidity 100% with condensation Wind speed Up to 150mph(240kph) Warranty 5 years Optional Available in flashing pattern(40FPM) Available with built-in photosensor Available with built-in alarm relay contacts ① ST: “Service+Standby” ② SS:”Service+Service” Order codes Series OL32 Single/ AC/ Alarm Voltage Flashing Photosensor Double DC relay R S A F P 12 Pattern(For double light only) D SS D 24 ST 48 110 Pipe diameter range 30-80 mm 220 Light Effective Intensity (candela) For example, OL32DA220SS means OL32 double light, AC220V power supply, red steady burning, “service+service” Ordering Code: AKU80 Mounting kit for 30-80mm vertical or horizonal pipe Photometric Performance 65 OL32 Data 55 FAA L810 minimum requirement 45 ICAO 32.5cd minimum requirement 30 15 ICAO 10cd minimum requirement Pipe diameter range 60-100 mm -5˚ 0˚ 5˚ 10˚ 15˚ Vertical Divergence (degrees) 20˚ 0 25˚ Ordering Code: AKU100 Mounting kit for 60-100mm vertical l pipe © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 08 OL100 LED Based Low Intensity Obstruction Light In some cases, a country has it's own Aviation regulation other than ICAO regulation. For example, Germany and Australia require more intensity from their local Aviation Authorities. REDDOT can make such light base on customer's request. Double light for customized low intensity series Double light is integrated by 2 single lights. For making sure there is always a light working atop of the tower. Two optional working patterns can meet different area’s customers. • “Service+Standby”: Only “service light” is working normally. It will auto-transfer to “standby light” in case of “service light” failure • “Service+Service”: Two single lights work simultaneously. Either failure will not affect the other normal working. Features • • • • • • • • Special optical design provides better light distribution LED light source esures long lifetime, maintenance free Low power consumption Shock and vibration resistant Corrosion resistant and UV stable polycarbonate housing Ease of mount, mount accessories available Available both in single and double type 5 years warranty Application • • • • • • • Telecomm tower Radio tower Wind turbine Somke stacks & chimney Tall building Crane Power transmission line 09 © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com Specifications LIGHT OUTPUT OL100S(Single) OL100DST①(Double) OL100DSS②(Double) Effective Intensity 100 Candela 100 Candela 100 Candela Vertical Divergence 10 Degree Horizontal 360 Degree LED color Red LED lifespan 100,000 Hours OPERATION Steady burning(default) Flash Pattern POWER SUPPLY Input voltage 110-220VAC, 50/60 Hz;12VDC;24VDC;48VDC Power Consumption 8W 8W 16W MACHANICAL STRUCTURE Lens Polycarbonate,UV Stabilized Body Die-casting Aluminum Water-proof IP65 Weight 0.9KG 3.5KG Dimension 159mmx245mm 340mmx413mmx140mm 340mmx413mmx140mm Mounting Size Threaded 3/4’’ bottom hub 3.5KG -40C˚ ~ +55C˚ Temperature Range Relative Humidity 100% with condensation Wind speed Up to 150mph(240kph) Warranty 5 years Optional Available in flashing pattern(40FPM) Available with built-in photosensor Available with built-in alarm relay contacts ① ST: “Service+Standby” ② SS:”Service+Service” Order codes Single/ AC/ Alarm Voltage Flashing Photosensor Double DC relay R A OL100 S F P 12 Series D D Pattern(For double light only) ST SS 24 48 110 Pipe diameter range 30-80 mm 220 Light Effective Intensity (candela) For example, OL100SA220PST means OL100 double light, AC220V power supply, red steady burning, with built-in photosensor, “service+standy” Ordering Code: AKU80 Mounting kit for 30-80mm vertical or horizonal pipe Photometric Performance 150 OL100 Data 120 FAA L810 minimum requirement 90 60 30 -5˚ 0˚ 5˚ 10˚ 15˚ Vertical Divergence (degrees) 20˚ 0 25˚ ICAO 32.5cd minimum requirement ICAO 10cd minimum requirement Pipe diameter range 60-100 mm Ordering Code: AKU100 Mounting kit for 60-100mm vertical l pipe © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 10 OL200 LED Based Low intensity Aviation Obstruction Light Reddot OL200 is a type of low intensity aviation obstruction light, peak intensity can be up to 200 Candelas, by far exceed International standard ICAO type B(32.5Candelas) Compliant Australia CASA Mos Part 139 UK CAP168 Low Intensity Obstacle(Group B) Features NFL 197-107/03, Neues feuer W-ROT • Configured ultra-bright LEDs technology ensure long-life and free maintenance • Low power consumption • Special lens design enhance LED efficient and distributes 360 degree visibility • Robust aluminum base with electrostatic powder painting, better corrosion-resistance • Self-contained design for wiring which eliminate additional junction box • Stainless steel Cable gland for easy cable entry and wring • Optional built-in photosensor, which can work independently, turn on/off automatically from dusk to dawn • Optional dry contact alarm relay, 3-pin side-entry screw terminal block ”NO-COM-NC” • Available steady-burning or flashing type • Light-weight and easy installation combined with REDDOT mounting kits Application • • • • • • Telecom&transmission tower Wind turbine Smoke stacks&chimney Oil offshore platform Crane High-rise building 11 © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 23.2 Specifications Light out-put Peak Intensity 200 cd Vertical Divergence +5 to +8 degree 200cd 0 to +15 degree 50cd Horizontal out-put 360 degree LED color Red(white, yellow, green, blue availabe) 10,000 hours 10.0 LED lifespan 204.5 Power supply Operation voltage 12VDC, 24VDC, 48VDC, 110VAC, 220VAC(50-60HZ) Steady-Burning or Flash Pattern Flashing(40FPM as defunit) 15W Power consumption 215.5 Mechanical structure Lens Polycarbonate, UV Stablized Body Aluminum die-casting Waterproof IP67 Weight 3.5KG 95.0 89° Ø177.0 Ø226.0 Temperature range -40C°-+50C° Relative Humidity 100% with condensation Dimensions 215.5mm Height, 226mm Diameter Optional Available with built-in photo sensor Available with built-in alarm relay Installation AMP3080 Ordering Code Series Single/Double AC/DC Voltage Flashing Photo sensor Alarm Relay OL200 S A 12 D D 24 F P R 48 110 220 AMP30150 REDDOT AMP mounting kit : Ordering Code Series Vertical tower leg diameter range Horizontal tower leg diameter range AMP3080 30-80mm 30-80mm AMP30150 30-150mm 30-80mm Light Effective Intensity (candela) 250 Photometric Performance 200 150 100 OL200 Data FAA L810 minimum requirement ICAO 32.5cd minimum requirement ICAO 10cd minimum requirement 50 -5˚ 0˚ 5˚ 10˚ 15˚ 20˚ 0 25˚ Vertical Divergence (degrees) © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 12 E27 LED lamp for low intensity Aviation Obstruction Light Reddot E27 LED lamp is specially designed for low intensity obstruction light. with Fresnel optic lens, in compliance with ICAO and FAA standard. Features Electronic characters: • Self-contained electronic control design • Based on LED technology, long lifetime, low maintenance cost • Extremely low power consumption, • Top mounted LED indicator for power supply and operation status • Over voltage protection • Reverse polarity protection • Available in DC12/24/48V and AC110/220C Mechanical characters: • Universal E27 lamp holder, easy replacement • Robust aluminum lamp body, providing better heat dissipation • Good anti-vibration Advantage Comparison Reddot E27 LED lamp Traditional LED lamp (incandescent , fluorescent) Very low power consumption (E27100 only 8W) High power consumption (100W or more) Reliable long lifetime, Low maintenance cost High replacement frequency Better anti-vibrant and robust structure Easy to break during transportation and installation Compact electronic control design, expandable functions(eg. built-in photosensor, flashing rate adjustable), can work standalone even without controller Not Electronics friendly, must work with controller E2732 © Copyright 2011 Reddot Electronics Co., Ltd 13 www.reddotsignal.com E2710 E27100 Specifications E2710 E2732 E27100 Effective Intensity (Work in light) >10cd >32.5cd >100cd Standard ICAO type A ICAO type B FAA L810 >ICAO type B >FAA L810 CASA LED Nos 8 16 16(High-Flux) Vertical Divergence 120 degree Horizontal Output 360 degree LED color Aviation Red, Other colors are available upon request LED lifespan 100,000 hours Operation pattern Steady-burning Ø52±0.5 LIGHT OUT-PUT Nominal Voltage 12VDC,24VDC,48VDC 110VAC, 220VAC 50/60HZ Power Consumption 4W 6W 128+50 Power Supply 8W Mechanical Structure Body Aluminum Base E27 Weight 0.15KG Temperature Range -40°C- +55°C Dimension 128mm*52mm(HxDia.) Warranty 5 year E27 Type Series AC/DC Voltage E27 10 A 12 32 D 24 100 48 110 220 For example, E2732D48 means, E27 LED lamp, effective intensity>32.5cd fitted in Fresnel lens, DC48V power supply , steady-burning. Photometric Performance (Work in light) 120 E2710 Data E2732 Data E27100 Data FAA L810 minimum requirement ICAO 32.5cd minimum requirement ICAO 10cd minimum requirement 115 110 105 100 95 90 85 80 75 70 65 60 55 Recommendation: 50 45 • 40 35 30 25 20 15 10 5 0 -20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 For buyers who have installed other brand-name obstruction light that with Fresnel Lens, REDDOT E27 lamp can fit into most of them after minor LED position change vertically. • Please consult our sales for further assistance. © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 14 Aviation Obstruction Light Medium ium ium iu m Int In Intensity tensity ensiity ty ty • OM2K M • OM OM2C-D M2 M 2C-D C-D http://www.reddotsignal.com/en/products/aviation/ http://www http://www.reddotsignal.com/en/produ reddotsignal com/en/pr ation/ on/ OM2K LED Based Medium Intensity Obstruction Light OM2K is a new generation medium intensity OB light. It comes with compact-size and light-weight, which makes installation job nice & easy. The optical part is based on Fresnel lens, a transformed convex lens which can concentrate light to a small specific angel to meet with ICAO requirements. Fresnel lens is often used to design obstruction light. OM2K Series Intensity 2000 cd Compliant with Steady ICAO : Medium intensity type C Flashing ICAO : Medium intensity type B FAA Type L864 The light's ingress protection level is IP67, assures the light is well sealed to stand harsh environment include the ocean. If work with control box, more functions like synchronization could be realized. GPS or GPRS functions also available if needed. Medium intensity light OM2K is for tower taller than 45m. It should be used either alone, or in combination with low-intensity light type B (our OL32 series). Features • Unique optical design complies with ICAO regulation • Aluminum head provides good thermal performance • Better shock-resistant perform than Xenon • Longer lifetime expectancy • Almost maintenance free • Lower voltage (than xenon) makes it safer for installer • Cost effective in long run • 5 years warranty Application • • • • Telecomm tower Radio tower Wind turbine Smoke stacks & chimney Standard • • • • ICAO Annex 14, 4th Edition, July 2004 ICAO medium intensity type B & type C FAA AC No. 150/5345-43F,2006 FAA type L864 © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 15 Specifications 160 LIGHT OUT-PUT 2000 Candela Peak Intensity Horizontal out-put 360 Degree LED Color Red LED Lifespan 100,000 Hours 210 -1° 950cd, Centering at 0.5° Vertical Divergence OPERATION Steady-burning or flashing Flash Pattern POWER SUPPLY Input voltage 110VAC ~ 220VAC, 24VDC, 48VDC Frequency 50Hz ~ 60Hz Rated consumption 40W with steady mode MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP67 Weight 4.5 KG -40 ~ +55 Temperature Range Relative humidity 100% with condensation Dimensions 210mm H, 226mm Diameter Warranty 5 years Optional Available with built-in photo sensor 226 Available with built-in Alarm relay Installation Order Codes Series Steady/flashing AC/DC Voltage Photo sensor Alarm relay OM2K C (steady) P R B (flashing) A 12 D 24 AMP3080 48 110 220 For example, OM2KBD24 means a DC 24V power supply, flashing Medium Iutensity beacon. REDDOT AMP mounting kit : Ordering Code AMP30150 Vertical tower leg diameter range Horizontal tower leg diameter range AMP3080 30-80mm 30-80mm AMP30150 30-150mm 30-80mm Photometric Performance 2500 2000 Peak Intensity 2000 -1˚ Intensity 950 1500 1000 500 Vertical Divergence (degrees) © Copyright 2011 Reddot Electronics Co., Ltd 16 www.reddotsignal.com -5 -4 -2 -3 0 -1 -1 -2 -3 -5 0 -4 Light Effective Intensity (candela) Series OM2K Data ICAO Maximum Requirement ICAO Minimum Requirement OM2C-D LED Based Medium Intensity Obstruction Light OM2C-D is a new generation medium intensity OB light. It comes with compact-size and light-weight, which makes installation job nice & easy. OM2C-D Series Peak Intensity 2000cd, steady The optical part is based on Fresnel lens, a transformed convex lens which can concentrate light to a small specific angel. Fresnel lens is often used to design obstruction light. The light's ingress protection level is IP67, assures the light is well sealed to stand harsh environment include the ocean. If work with control box, more functions like synchronization could be realized. GPS or GPRS functions also available if needed. Medium intensity light OM2C-D is for tower taller than 45m. It should be used either alone, or in combination with low-intensity light type B (our OL32). The light comes with a plug type connection, which makes installation nice & easy. When the light has a built-in alarm relay, one more plug will be added to the base (alarm function needs 2 core shielded cable). A junction box that mounted on the double bracket has a PCB who can auto transfer to the standby light in case of failure of the service light, in “service+standby” mode. Features • • • • • • • • Unique optical design complys with ICAO regulation Aluminum head provides good thermal performance Better shock-resistant perform than Xenon Longer lifetime expectancy Almost maintenance free Lower voltage (than xeon) makes it safer for installer Cost effective in long run 5 years warranty Application • • • • Telecomm tower Radio tower Wind turbine Somke stacks & chimney Standard • ICAO Annex 14, 4th Edition, July 2004 © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 17 Specifications 160 LIGHT OUT-PUT 2000 Candela Peak Intensity Horizontal out-put 360 Degree LED Color Red LED Lifespan 100,000 Hours 210 -1° 450cd, Centering at 0.5° Vertical Divergence OPERATION Steady-burning Flash Pattern POWER SUPPLY Input voltage 110VAC ~ 220VAC, 24VDC, 48VDC Frequency 50Hz ~ 60Hz Rated consumption 40W (service+standby) 80W (service+service) MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP67 Weight 12 KG -40 ~ +55 Temperature Range 226 Relative humidity 100% with condensation Dimensions 210mm H, 226mm Diameter (for one lamp) Warranty 5 years Optional Available with built-in photo sensor Avalaible with built-in alarm relay 15 ① ST: “Service+Standby” Order Codes Series Steady/ flashing OM2C-D C (steady) B (flashing) AC/DC Voltage Photo sensor Alarm relay Pattern(For double light only) A 12 P R ST D 24 SS 48 110 220 For example, OM2KBD24 means a DC 24V power supply, flashing Medium Iutensity beacon. © Copyright 2011 Reddot Electronics Co., Ltd 18 www.reddotsignal.com ② SS:”Service+Service” Aviation Obstruction Light Solar Series • • • • • • • • • • • OLS10 OLS32 OM2BS PL10 PL10A PL10D PL10S OLIS10-V OLIS32-V OLIS32 OLIS50 http://www.reddotsignal.com/en/products/aviation/ OLS10 Solar Powered Low Intensity Obstruction Light OLS10 series is solar powered obstruction light. Solar OLS10 Series function make it a self-contained and alomst care-free Intensity light unit. Compliant with The light system is composed of 3 parts, light, battery box and solar panel. When the light and solar panel connected to the battery box, the whole system can be mounted on a tower. Both vertical mounting and horizontal mounting are ok. OLS10 is equipped with a 10Ah VRLA (volve regulated lead acid) rechargeable battery which could power the light up to 5 days when the weather is cloudy & rainy. The 10Ah VRLA battery is also easy to find almost anywhere. Both single light & double light are available in this series. Features • Green enegy • Ultra-light LEDs, energy saving • Self-contained without outside power supply • Maximum visibility distance 4 KM • Once fully charged, it can work for up to 60 hours • Cable cost saving & cabling job saving • No wiring job, nice & easy installation Applications • Telecomm tower • Radio tower • Wind turbine • Somke stacks & chimney • Tall building • Power transmission line Standard • ICAO Annex 14, 4th Edition, July 2004 • ICAO low intensity, type A © Copyright 2011 Reddot Electronics Co., Ltd 19 www.reddotsignal.com 10cd, steady ICAO : low intensity type A FAA : N/A Specifications 600.0 266.0 LIGHT OUT-PUT Effective Intensity 10 Candela Vertical Divergence -3°~20° more than 10cd, Centering at 10° Horizontal out-put 360 Degree LED Color Red LED Lifespan 100,000 Hours 300.0 352 OPERATION Steady Flash Pattern 420.0 POWER SUPPLY Solar panel 17.5V / 15W module Rechargeable battery VRLA, 12V / 10Ah Autonomy 5 days (in cloudy & raning weather) MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP65 Weight 11 KG 205.0 -40C˚ ~ +55C˚ Temperature Range Relative humidity 100% with condensation Battery box dimensions 352mm H, 204mm W, 650mm L Solar module dimensions 420mm * 300mm * 28mm Warranty 5 years for light body, 10 years for solar panel 2 years for VRLA battery Order codes Series Single/Double OLS10 S D For example, OLS10S means a solar powered single light Horizontal Mount Vertical Mount © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 20 OLS32 Solar Powered Low Intensity Obstruction Light OLS32 series is solar powered obstruction light. Solar unction make it a self-contained and alomst care-free ght unit. he light system is composed of 3 parts, light, battery box nd solar panel. When the light and solar panel connected o the battery box, the whole system can be mounted on a ower. Both vertical mounting and horizontal mounting are ok. OLS32 is equipped with a 20Ah VRLA (volve regulated ead acid) rechargeable battery which could power the ght up to 5 days when the weather is cloudy & rainy. The 0Ah VRLA battery is also easy to find almost anywhere. oth single light & double light are available in this series. eatures Green enegy Ultra-light LEDs, energy saving Self-contained without outside power supply Maximum visibility distance 5 KM Once fully charged, it can work for up to 60 ours Cable cost saving & cabling job saving No wiring job, nice & easy installation pplications Telecomm tower Radio tower Wind turbine Somke stacks & chimney Tall building Power transmission line tandard ICAO Annex 14, 4th Edition, July 2004 ICAO low intensity, type B AA AC150/5345-43F, 2006 AA, type L810 © Copyright 2011 Reddot Electronics Co., Ltd 21 www.reddotsignal.com OLS32 Series Intensity Compliant with 32.5cd, steady ICAO : low intensity type B FAA : L810 Specifications 700.0 LIGHT OUT-PUT 266.0 Effective Intensity 32.5 Candela Vertical Divergence -3°~20° more than 10cd, Centering at 10° Horizontal out-put 360 Degree LED Color Red LED Lifespan 100,000 Hours 410 352.0 OPERATION Steady Flash Pattern 600 POWER SUPPLY Solar panel 17.5V / 30W module Rechargeable battery VRLA, 12V / 20Ah Autonomy 5 days (in cloudy & raning weather) MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP65 Weight 15 KG 204.8876 -40C˚ ~ +55C˚ Temperature Range Relative humidity 100% with condensation Battery box dimensions 352mm H, 204mm W, 650mm L Solar module dimensions 600mm * 410mm * 28mm Warranty 5 years for light body, 10 years for solar panel 2 years for VRLA battery Order codes Series Single/Double OLS32 S D For example, OLS32D means a solar powered double light Horizontal Mount Vertical Mount © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 22 OM2BS Solar Based Medium Intensity Obstruction Light OM2BS series is solar powered obstruction light. Due to solar module's limitation like solar panel size and battery size, the light is being designed to work under flashing mode instead of stead-burning mode. But advantages like enegy saving and cable saving make the solar powered light a good option on obstruction marking. Features • Green enegy • Cable cost saving & cabling job saving • No wiring job, nice & easy installation Application • • • • • • Telecomm tower Radio tower Wind turbine Somke stacks & chimney Tall building Power transmission line Standard • ICAO Annex 14, 4th Edition, July 2004 • ICAO medium intensity, customized © Copyright 2011 Reddot Electronics Co., Ltd 23 www.reddotsignal.com OM2BS Series Intensity 2000 cd, Flashing Compliant with ICAO : Medium intensity type B Specifications LIGHT OUT-PUT 2000 Candela Effective Intensity Peak intensity at 1° with 3° spread angle Vertical Divergence Horizontal out-put 360 Degree LED Color Red LED Lifespan 100,000 Hours 226 OPERATION 515.5 Flashing (default 40FPM) Flash Pattern 264.0 POWER SUPPLY 17.5V / 15W module Rechargeable battery lead-acid type, 12V / 12Ah (VRLA) Autonomy 8 days (in cloudy & raning weather) 210 160 Solar panel MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP65 Weight 11 KG Temperature Range -40°C ~ +55°C Relative humidity 100% with condensation Light dimensions 200mm H, 178mm Diameter Solar module dimensions 420mm * 600mm (bracket not included) Light module dimensions 625mmH, 515mmL, 450mmW Warranty 5 years for light body 2 years for battery 10 years for solar module 545 OM2B-A Series Photometric Performance Light Effective Intensity (candela) 2500 Peak Intensity 2000 -1˚ Intensity 950 2000 1500 1000 500 OM2B-A Data ICAO Maximum Requirement ICAO Minimum Requirement -5 -4 -3 -2 -1 0 -1 -2 -3 -4 -5 0 Vertical Divergence (degrees) © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 24 PL10 Solar Powered Obstruction Light The solar panel comes with PL10 provides power supply to the light, which makes PL10 a self-contained and care-free light unit. Also, with the solar function, the light is easy to deploy to almost any condition and any emergency case. Robust body built and surface coating provides good protection against hash environments. Compliant ICAO Annex 14, Volume 1, 4th Edition, July 2004 FAA Advisory Circular AC150/5370-2F PL10 is equipped with an 8Ah NiMH rechargeable battery which could power the light up to 20 days when the weather is cloudy & rainy. NiMH battery is also a clean power source with no pollution. The NiMH battery is also easy to find almost anywhere. PL10 is also available with an optional on/off switch for storing and protect battery from over-discharging. Features • • • • Ultra-light LEDs, energy saving Self-contained without outside power supply Maximum visibility distance 4 KM Once fully charged, it can work for up to 200 hours • Auto-off after being packed for 18 hours Application • • • • • • • High-rise building marking Telecom tower marking Road obstruction marking Navigation aid Port, dock entrance & walkway Buoy marking Offshore gas & oil platform © Copyright 2011 Reddot Electronics Co., Ltd 25 www.reddotsignal.com Specifications 23.2 LIGHT OUT-PUT Intensity FLASHING Red: >10cd Green:>20cd White:>25cd Blue:>5cd Yellow: >10cd STEADY Red: >4cd White:>10cd Yellow: >4cd Green: >8cd Blue:>2cd Nominal Night Range >4 KM LED Color Available Red, Green, Yellow, White, Blue Vertical Divergence 10 Degree Horizontal Out-put 360 Degree Illumination Ultra-bright LEDs LED Lifespan 100,000 Hours 10.0 204.5 OPERATION Autonomy Flashing : 200 Hours / Steady : 100 Hours On & Off Level 70/100 Lux Flash Pattern 40FPM default(can be preprogrammed to a specified flashing rate upon customer request) 215.5 95.0 89° POWER SUPPLY Power Source Solar module, mono-crystalline silicon Solar Efficiency 13.5% Ø177.0 Ø226.0 Max. Power Out-put 1.8 Watts Battery Type High-efficiency NiMH rechargeable battery Battery Capacity 8 AH / 3.6V Battery Replacement Yes, replaceable Installation MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP67 Weight 3.5 KG Temperature Range -40C˚ ~ +55C˚ Dimensions 215.5mm H, 226mm Diameter Warranty 5 years for light AMP3080 2 years for NiMH battery Note: when the light is in storage, please put it outside to charge the battery every 3 months REDDOT AMP mounting kit : Ordering Code AMP30150 Series Vertical tower leg diameter range Horizontal tower leg diameter range AMP3080 30-80mm 30-80mm AMP30150 30-150mm 30-80mm © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 26 PL10A Solar Powered Obstruction Light PL10A based on PL10 basic features, configured synchronization and alarm signal output functions. An internal solar panel comes with PL10A, provides power supply to the light, which makes PL10A a selfcontained and care-free light unit. Also, with the solar function, the light is easy to deploy to almost any condition and any emergency case. Robust body built and surface coating provides good protection against hash environments. PL10A is equipped with an 8Ah NiMH rechargeable battery which could power the light up to 20 days when the weather is cloudy & rainy. NiMH battery is also a clean power source with no pollution. The NiMH battery is also easy to find almost anywhere. Features Application • • • • • • • • • • • • • Ultra-light LEDs, energy saving Dry contact type alarm out-put Group Synchronization by sync data shielded cable One unit Can be working independently as PL10 Once fully charged, it can work for up to 200 hours Auto-off after being packed for 18 hours High-rise building marking Telecom tower marking Road obstruction marking Navigation aid Port, dock entrance & walkway Buoy marking Offshore gas & oil platform 1 1. Built-in 1.8W solar panel 2. Data interface for synchronization and alarm signal output 3. 4-pin IP67 cable connector 2 3 3 © Copyright 2011 Reddot Electronics Co., Ltd 27 www.reddotsignal.com Specifications 23.2 LIGHT OUT-PUT Intensity FLASHING Red: >10cd Green:>20cd White:>25cd Blue:>5cd Yellow: >10cd STEADY Red: >4cd White:>10cd Yellow: >4cd Green: >8cd Blue:>2cd Nominal Night Range >4 KM LED Color Available Red, Green, Yellow, White, Blue Vertical Divergence 10 Degree Horizontal Out-put 360 Degree Illumination Ultra-bright LEDs LED Lifespan 100,000 Hours 10.0 204.5 OPERATION Autonomy Flashing : 200 Hours / Steady : 100 Hours On & Off Level 70/100 Lux Flash Pattern 40FPM default(can be preprogrammed to a specified flashing rate upon customer request) 215.5 95.0 89° POWER SUPPLY Power Source Solar module, mono-crystalline silicon Solar Efficiency 13.5% Ø177.0 Ø226.0 Max. Power Out-put 1.8 Watts Battery Type High-efficiency NiMH rechargeable battery Battery Capacity 8 AH / 13.6V Battery Replacement Yes, replaceable Installation MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP67 Weight 3.5 KG Temperature Range -40C˚ ~ +55C˚ Dimensions 215.5mm H, 226mm Diameter Warranty 5 years for light AMP3080 2 years for NiMH battery Note: when the light is in storage, please put it outside to charge the battery every 3 months AMP30150 REDDOT AMP mounting kit : Ordering Code Series Vertical tower leg diameter range Horizontal tower leg diameter range AMP3080 30-80mm 30-80mm AMP30150 30-150mm 30-80mm Note: details referred to REDDOT RDM-AMP-04 and RDMP-AMP-06 © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 28 PL10D Double Solar powered Aviation obstruction light Based on REDDOT PL10, PL10D is a “twin” model which can be working synchronization. An internal solar panel comes with each single light of PL10D, provides power supply to the light, which makes PL10D a self-contained and care-free light unit. Also, with the solar function, the light is easy to deploy to almost any condition and any emergency case. Robust body built and surface coating provides good protection against hash environments. PL10D is equipped with an 8Ah NiMH rechargeable battery for each single which could power the light up to 20 days in flashing mode when the weather is cloudy & rainy. NiMH battery is also a clean power source with no pollution. The NiMH battery is also easy to find almost anywhere. Features Application • Ultra-Bright LED, energy saving • Self-contained without outside power supply • Maximum visibility distance 4 KM • Once fully charged, it can work for up to 200hours • Auto-off after being packed for 18 hours • Either single light fails will not affect the other normal working • • • • • • • High-rise building marking Telecom tower marking Road obstruction marking Navigation aid Port, dock entrance & walkway Buoy marking Offshore gas & oil platform 2 1 3 4 5 1. Master light 2. Slave light 3. PG9 cable gland © Copyright 2011 Reddot Electronics Co., Ltd 29 www.reddotsignal.com 4. 3*0.5mm2 shield cable 5. IP68 4-pin cable connector Specifications 23.2 LIGHT OUT-PUT Intensity FLASHING Red: >10cd Green:>20cd White:>25cd Blue:>5cd Yellow: >10cd STEADY Red: >4cd White:>10cd Yellow: >4cd Green: >8cd Blue:>2cd Nominal Night Range >4 KM LED Color Available Red Vertical Divergence 10 Degree Horizontal Out-put 360 Degree Illumination Ultra-bright LEDs LED Lifespan 100,000 Hours 10.0 204.5 OPERATION Autonomy Flashing : 200 Hours / Steady : 100 Hours On & Off Level 70/100 Lux Flash Pattern 40FPM default(can be preprogrammed to a specified flashing rate upon customer request) 215.5 95.0 89° POWER SUPPLY Power Source Solar module, mono-crystalline silicon Solar Efficiency 13.5% Ø177.0 Max. Power Out-put 1.8 Watts Ø226.0 Battery Type High-efficiency NiMH rechargeable battery Battery Capacity 8 AH / 13.6V Battery Replacement Yes, replaceable MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP67 Weight 3.5 KG Temperature Range -40C˚ ~ +55C˚ Dimensions 215.5mm H, 226mm Diameter Warranty 5 years for light Installation 2 years for NiMH battery Note: when the light is in storage, please put it outside to charge the battery every 3 months REDDOT AMP-D mounting kit: Ordering Code Ordering Code Suitable for pipe diameter Installation type AMP-D-80 30-80mm Vertical AMP-D-100 60-100mm Vertical AMP-D-150 100-150mm Vertical Noting: Details referred to REDDOT RDM-AMP-D-02 drawing. © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 30 PL10S Solar powered obstruction light PL10S is a member of PL10 series, configured two toggle switches. An internal solar panel comes with PL10S, provides power supply to the light, which makes PL10S a self-contained and care-free light unit. Also, with the solar function, the light is easy to deploy to almost any condition and any emergency case. Robust body built and surface coating provides good protection against hash environments. PL10S is equipped with an 8Ah NiMH rechargeable battery which could power the light up to 20 days when the weather is cloudy & rainy. NiMH battery is also a clean power source with no pollution. The NiMH battery is also easy to find almost anywhere. Two toggle switches built on PL10S body: 1. ON/OFF for saving power consumption and protecting battery from over-discharging during storing or transportation. 2. AUTO/MANUAL for EMERGENCY use. AUTO : auto-switch on/off from dusk to dawn MANUAL : mandatary-switch on Features • • • • Ultra-light LEDs, energy saving Self-contained without outside power supply Maximum visibility distance 4 KM Once fully charged, it can work for up to 200 hours • Auto-off after being packed for 18 hours 1 Application • • • • • • • High-rise building marking Telecom tower marking Road obstruction marking Navigation aid Port, dock entrance & walkway Buoy marking Offshore gas & oil platform 1. Built-in 1.8W solar panel 2 2. On/Off toggle switch 3. Auto/Manual toggle switch © Copyright 2011 Reddot Electronics Co., Ltd 31 www.reddotsignal.com 3 Specifications 23.2 LIGHT OUT-PUT Intensity FLASHING Red: >10cd Green:>20cd White:>25cd Blue:>5cd Yellow: >10cd STEADY Red: >4cd White:>10cd Yellow: >4cd Green: >8cd Blue:>2cd Nominal Night Range >4 KM LED Color Available Red Vertical Divergence 10 Degree Horizontal Out-put 360 Degree Illumination Ultra-bright LEDs LED Lifespan 100,000 Hours 10.0 204.5 OPERATION Autonomy Flashing : 200 Hours / Steady : 100 Hours On & Off Level 70/100 Lux Flash Pattern 40FPM default(can be preprogrammed to a specified flashing rate upon customer request) 215.5 95.0 89° POWER SUPPLY Power Source Solar module, mono-crystalline silicon Solar Efficiency 13.5% Ø177.0 Max. Power Out-put 1.8 Watts Ø226.0 Battery Type High-efficiency NiMH rechargeable battery Battery Capacity 8 AH Battery Replacement Yes, replaceable MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP67 Weight 4.5 KG Temperature Range -40C˚ ~ +55C˚ Dimensions 215.5mm H, 226mm Diameter Warranty 5 years for light Installation 2 years for NiMH battery Note: when the light is in storage, please put it outside to charge the battery every 3 months REDDOT AMP-D mounting kit: Ordering Code Ordering Code Suitable for pipe diameter Installation type AMP-D-80 30-80mm Vertical AMP-D-100 60-100mm Vertical AMP-D-150 100-150mm Vertical Noting: Details referred to REDDOT RDM-AMP-D-02 drawing. © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 32 OLIS10-V Solar Based Low Intensity Obstruction Light OLS10-V series is solar powered obstruction light. OLIS10-V Series Solar function make it a self-contained and alomst Intensity 10cd, steady care-free light unit. Also, with the solar function, the Compliant with ICAO : low intensity type A light is easy to deploy to almost any condition and FAA : N/A any emergency case. Robust body built and surface coating provides good protection against hash environments. Other advantages like enegy saving and cable saving make the solar powered light a good option on obstruction marking. OLIS10-V is equipped with a 8Ah VRLA (volve-regulated lead acid) rechargeable battery which could power the light up to 5 days when the weather is cloudy & rainy. The 7.2Ah VRLA battery is also easy to find almost anywhere. Features • Green enegy • Ultra-light LEDs, energy saving • Self-contained without outside power supply • Maximum visibility distance 4 KM • Once fully charged, it can work for up to 60 hours • Auto-off after being packed for 18 hours • Cable cost saving & cabling job saving • No wiring job, nice & easy installation Application • Telecomm tower • Radio tower • Wind turbine • Somke stacks & chimney • Tall building • Power transmission line Standard • ICAO Annex 14, 4th Edition, July 2004 • ICAO low intensity, type A © Copyright 2011 Reddot Electronics Co., Ltd 33 www.reddotsignal.com Specifications 390.50 10 Candela Vertical Divergence 10 Degree Horizontal out-put 360 Degree LED Color Red, Green, Yellow, White, Blue LED Lifespan 100,000 Hours 15° Effective Intensity 296 LIGHT OUT-PUT OPERATION Steady-burning > 10CD Flashing > 32.5CD Flash Pattern 314 POWER SUPPLY 17.5V / 5W module Rechargeable battery VRLA type, 8Ah/12V Autonomy 5 days (in cloudy & raning weather) 164 Solar panel MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP67 Weight 9 KG Temperature Range -40C˚ ~ 60C˚ Relative humidity 100% with condensation Light dimensions 296mm H, light diameter 235mm Solar module dimensions 164mm * 314mm Warranty 5 years for light body, 2 years for VRLA battery Note: when the light is in storage, please put it outside to charge thebattery every 3 months Light Effective Intensity (candela) 25 Photometric Performance 20 15 OLIS10-V Data ICAO 10cd minimum requirement 10 5 -5˚ 0˚ 5˚ 10˚ 15˚ 20˚ 0 25˚ Vertical Divergence (degrees) © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 34 OLIS32-V Solar Based Low Intensity Obstruction Light OLIS32-V solar powered obstruction light, solar self-contained design makes it easy to install any condition and any emergency case. OLIS32-V Intensity Compliant with 32.5cd, steady ICAO : low intensity type B FAA : L810 Robust body built and surface coating provides DGAC Mexico good protection against hash environments. Other advantages like energy saving and cable saving make the solar powered light a good option on obstruction marking. OLIS32-V is equipped with a 16Ah VRLA (volve-regulated lead acid) rechargeable battery which could power the light up to 5 days when the weather is cloudy &rainy. The 16Ah VRLA battery is also easy to find almost anywhere. Features • Green energy • Ultra-light LEDs, energy saving • Self-contained without outside power supply • Maximum visibility distance 5KM • Once fully charged, it can work for up to 60 hours • Auto-off after being packed for 18 hours • Cable cost saving & cabling job saving • No wiring job, nice & easy installation Standard • ICAO Annex 14, 4th Edition, July 2004 • ICAO low intensity, type B • FAA AC No. 150/5345-43F, 2006 • FAA type L810 © Copyright 2011 Reddot Electronics Co., Ltd 35 www.reddotsignal.com Application • Telecomm tower • Radio tower • Wind turbine • Somke stacks & chimney • Tall building • Power transmission line Specifications LIGHT OUT-PUT Intensity 32.5 Candela LED Color Available Red Vertical Divergence 10 degree Horizontal Out-put 360 degree Illumination Ultra-bright LEDs LED Lifespan 100,000 hours OPERATION Autonomy Steady: 5 days(14 hours/day) On & Off Level 70/100 Lux Flash Pattern Steady-burning > 10CD Flashing > 32.5CD Ø 177 Solar module, mono-crystalline silicon Solar Efficiency 13.5% Max. Power Out-put 20 Watts Battery Type High-efficiency Lead-Acid rechargeable battery Battery Capacity 16 AH / 12V Battery replacement Yes, replaceable 448 Power Source MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP67 Weight 10 KG Temperature Range -40C° ~ +55C° Light Dimensions 296mm H, 235mm Diameter Solar Module dimension 306mm*420mm Warranty 5 years for light 2 years for VARA battery Note: when the light is in storage, please put it outside to charge the battery every 3 months Light Effective Intensity (candela) 65 Photometric Performance 55 45 30 15 -5˚ 0˚ 5˚ 10˚ 15˚ 20˚ 0 25˚ Vertical Divergence (degrees) © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 36 324 POWER SUPPLY OLIS32 Solar Powered Low Intensity Obstruction Light The solar panel comes with OLIS32 provides power supply to the light, which makes OLIS32 a self-contained and care-free light unit. Also, with the solar function, the light is easy to deploy to almost any condition and any emergency case. Robust body built and surface coating provides good protection against hash environments. OLIS32 Series Intensity Compliant with 32.5cd, flashing ICAO : N/A FAA : N/A OLIS32 is equipped with an high-efficiency rechargeable battery which could power the light up to 20 days when the weather is cloudy & rainy. The rechargeable battery is also easy to find almost anywhere. OLIS32 is working under flashing mode, while ICAO requires that the low intensity light to be steady. But, anyway, OLIS32 could be a alternative option for some special needs. Features • • • • • Ultra-light LEDs, energy saving Self-contained without outside power supply Maximum visibility distance 5 KM Once fully charged, it can work for up to 200 hours Auto-off after being packed for 18 hours Application • • • • • • • High-rise building marking Telecom tower marking Road obstruction marking Navigation aid Port, dock entrance & walkway Buoy marking Offshore gas & oil platform © Copyright 2011 Reddot Electronics Co., Ltd 37 www.reddotsignal.com Specifications Ø177 FLASHING Intensity 32.5 Candela Nominal Night Range >5 KM LED Color Available Red, Green, Yellow, White, Blue Vertical Divergence 10 Degree Horizontal Out-put 360 Degree Illumination Ultra-bright LEDs LED Lifespan 100,000 Hours 297.80 LIGHT OUT-PUT 174 OPERATION Autonomy 200 Hours On & Off Level 70/100 Lux Flash Pattern Steady 20-90FPM (Preprogrammed default 40FPM) Power Source Solar module, mono-crystalline silicon Solar Efficiency 13.5% Max. Power Out-put 12 Watts Battery Type High-efficiency Lead-Acid rechargeable battery Battery Capacity 12V / 8AH Battery Replacement Yes, replaceable Ø235 51 6 POWER SUPPLY Lens Polycarbonate, UV Stabilize Body Extrude-Aluminum Water-proof IP67 Weight 9 KG Temperature Range -40C˚ ~ +55C˚ Dimensions 298mm H, 235mm Diameter Warranty 5 years for light 199.78 MECHANICAL STRUCTURE 2 years for Lead-Acid battery 199.78 Note: when the light is in storage, please put it outside to charge the battery every 3 months Light Effective Intensity (candela) 65 Photometric Performance 55 45 30 15 -5˚ 0˚ 5˚ 10˚ 15˚ 20˚ 0 25˚ Vertical Divergence (degrees) © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 38 OLIS50 Solar Based Low Intensity Obstruction Light The solar panel comes with OLIS50 provides power supply to the light, which makes OLIS50 a self-contained and care-free light unit. Also, with the solar function, the light is easy to deploy to almost any condition and any emergency case. Robust body built and surface coating provides good protection against hash environments. OLIS50 is equipped with an high-efficiency rechargeable battery is also easy to find almost anywhere. OLIS50 is working under flashing mode, while ICAO requires that the low intensity light to be steady. But, anyway, OLIS50 could be a alternative option for some special needs. Features • Ultra-light LEDs, energy saving • Self-contained without outside power supply • Maximum visibility distance 6 KM • Once fully charged, it can work for up to 200 hours • Auto-off after being packed for 18 hours Application • • • • • • • High-rise building marking Telecom tower marking Road obstruction marking Navigation aid Port, dock entrance & walkway Buoy marking Offshore gas & oil platform © Copyright 2011 Reddot Electronics Co., Ltd 39 www.reddotsignal.com OLIS50 Series Intensity Compliant with 50cd, flashing ICAO : N/A FAA : N/A Specifications FLASHING Intensity 50 Candela Nominal Night Range >6 KM LED Color Available Red Vertical Divergence 10 Degree Horizontal Out-put 360 Degree Illumination Ultra-bright LEDs LED Lifespan 100,000 Hours OPERATION Autonomy 200 Hours On & Off Level 70/100 Lux Flash Pattern Steady 20-90FPM (Preprogrammed default 40FPM) 324 LIGHT OUT-PUT 448 Ø 177 POWER SUPPLY Power Source Solar module, mono-crystalline silicon Solar Efficiency 13.5% Max. Power Out-put 20 Watts Battery Type High-efficiency Lead-Acid rechargeable battery Battery Capacity 12V / 16AH Battery Replacement Yes, replaceable Ø 235 Ø 16 MECHANICAL STRUCTURE Polycarbonate, UV Stabilize Body Die-casting Aluminum Water-proof IP67 Weight 13.5 KG Temperature Range -40C˚ ~ +55C˚ Dimensions 448mm H, 235mm Diameter Warranty 5 years for light 200 Lens 2 years for Lead-Acid battery Note: when the light is in storage, please put it outside to charge the battery 200 every 3 months Light Effective Intensity (candela) 100 Photometric Performance 80 60 40 20 -5˚ 0˚ 5˚ 10˚ 15˚ 20˚ 0 25˚ Vertical Divergence (degrees) © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 40 Aviation Obstruction Light CTR Control Box Series • • • • • CTR04 CTR04A CTR04B CTR04-B20 CTR04-AIDO http://www.reddotsignal.com/en/products/aviation/ h http // w r d otsignal.com/ com/en/p ducts/av viation/ CTR04 Control Panel Indoor Type CTR04 is a microprocessor indoor control panel device for monitoring and controlling obstruction lights, mostly for telecom, GSM, Microwave and TV towers. Connected with external photocell, the control panel will turn on/off automatically obstruction lighting system from dusk to dawn. Even at day time, the control panel is still in monitoring status. CTR04 can be preprogrammed for different obstruction lighting configurations. Features • Control up to four channels light output, each channel control up to four LED low intensity obstruction light or one LED low intensity double obstruction light. • Steady-burning and flashing mode adjustable by DIP switch • Auto/manual mode by DIP switch • Photocell with prewired shielded cable in five meters long • Transfer relay for “service+standby” double obstruction light system • LED indicator for lights, power, photocell operation status • Dry contact alarm output for lights and power • NO or NC alarm output contacts optional as customer alarm device type • 35mm Din-rail mounting rail , easy to install Specifications Description Parameter Input Voltage • • • Power consumption 2W Flash rate Steady-Burning/40FPM(default) Photocell sensitivity 70/100Lux Operating temperature range -30℃——+60℃ Enclosure PC 85-265VAC, 50/60HZ 48VDC 24VDC Protection class IP20 Dimension(HxWxDepth) 155x110x65mm Weight 0.5kg © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 41 CTR04A Control Box CTR04A control box is a microprocessor outdoor controller device for monitoring and controlling obstruction lights, mostly for telecom, GSM, Microwave and TV towers. Connected with external photocell, the control panel will turn on/off automatically obstruction lighting system from dusk to dawn. Even at day time, the control panel is still in monitoring status. CTR04 can be preprogrammed for different obstruction lighting configurations. Features MECHANICAL • Aluminum alloy Enclosure, IP67, outdoor type, good corrosion resistance • Circuit breaker switch, surge protection and terminal block are suitable for DIN rail mounting • The enclosure door is secured by four captive screws • Supplied with PG13.5 cable glands • Four threaded mounting holes in the back of control box, suitable for attaching to any vertical surface or rack mounting. ELECTRICAL • Control up to four channels light output, each channel control up to four LED low intensity obstruction lights or one LED medium intensity beacon. • Steady-burning and flashing mode adjustable by DIP switch • Auto/manual mode by DIP switch • Photocell with prewired shielded cable in five meters long • Transfer relay for “service+standby” double obstruction light system • LED indicator for lights, power, photocell operation status • Dry contact alarm output for lights and power • NO or NC alarm output contacts optional as customer alarm device type • Overvoltage protection and MOV surge protection • Circuit breaker protection and fuse protection Specifications Parameter Input Voltage • • Power consumption 10W Flash rate Steady-Burning/40FPM(default) Photocell sensitivity 70/100Lux Operating temperature range -30℃——+60℃ Enclosure Aluminum alloy Protection class IP67 Dimension(HxWxDepth) 320x219x104mm Weight 3.9kg 85-265VAC, 50/60HZ 48VDC • 24VDC © Copyright 2011 Reddot Electronics Co., Ltd 42 www.reddotsignal.com Typical System Application 45<H<90M H≤45M OM2B-A OL10D OL32D OL32S OL10S OL32S 45M<H<105M OL32S OL10S JB JB BTS BTS BTS Alarm Alarm Power Alarm Power Alarm mornitoring in BTS Obstruction light system for telecom tower ≤ 45 meters Power Alarm mornitoring in BTS Alarm mornitoring in BTS T90-OL101D2SC 48VDC obstruction lighting system for 45-90m tower TK90A solution: Steady Medium intensity system double obstruction lighting system Functions & features • Control one low intensity double light on the top • Under “service+standby” system, configured transfer relay in the control box, in case of service lam failure, will transfer to standby lamp • In “Service+service”type, either failure will output signal to the control box • One unit of OL10D double light on the top • Two units of OL10S single lights on 1/2 or 2/3 height of tower • OL10D double and OL10S single lights are integrated into one junction box • Alarm output for double light • Alarm output for single lights level • Alarm output for power supply • Photocell auto switch on/off the tower obstruction lighting system from dusk to dawn The height of structure more than 45meter but less than 105m, should install medium intensity on the top level and low intensity at the intermediate level • Top level : 1 or 2 units medium intensity(OM2B-A) red Steady • Intermediate level : 3 units L-810 low intensity(OL32S) red steady burning, or 4 units if square tower Note: • Each level will be alarmed independently • Any OB light of Each level failure will output alarm signal to control box Wiring method Please connect the power cord according to the label instruction 1 2 3 N 4 L 5 NULL Poewr 6 N 7 L 8 N Lamp1 L 9 10 NULL 11 N Lamp2 L Lamp3 12 N 13 L 15 Com NC Lamp1 Alarm 16 17 18 Com NC Com 19 20 21 NC Com NC 22 Com Lamp2 Alarm Lamp3 Alarm Lamp4 Alarm Power 23 AL:4 NO:3 AL:3 NO:2 AL:2 NO:1 AL:1 Charging Power Power off Auto Operation Lamp4 Photocell - photocell control terminal “Power” - controller power input Lamp1, Lamp2, Lamp3, Lamp4 - connect to aviation obstruction light separately 14 NO:4 24 25 NULL NO:1, NO:2, NO:3, NO:4 are 4 aviation obstruction light indicators individully. 26 Green light means working fine. Red light AL1, AL2, AL3, AL4 means corresponding light has failed. NC Alarm Photocell Lamp1 Alarm, Lamp2 Alarm, Lamp3 Alarm, Lamp4 Alarm output alarm terminal • Please make sure all wiring job are correct. Connecting the power supply, then the controller will start to work © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 43 CTR04B Obstruction Light Control Box CTR04B control box is an updated microprocessor outdoor controller device for monitoring and controlling obstruction lights, mostly for telecom, GSM, Microwave and TV towers. Compare with CTR04A, CTR04B have more friendly LED monitoring display, Both NO and NC alarm contacts are available. Features MECHANICAL • Aluminum alloy Enclosure, IP67, outdoor type, good corrosion resistance • Circuit breaker switch, surge protection and terminal block are suitable for DIN rail mounting • The enclosure door is secured by four captive screws • Supplied with PG13.5 cable glands • Four threaded mounting holes in the back of control box, suitable for attaching to any vertical surface or rack mounting. ELECTRICAL • Control up to four channels light output, each channel control one medium intensity LED beacon or up to four L-810 low intensity LED single obstruction light. • Steady-burning and flashing mode adjustable by DIP switch • Auto/manual mode by DIP switch • Photocell with prewired shielded cable in five meters long • Transfer relay for “service+standby” double obstruction light system • LED indicator for lights, power, photocell operation status • Dry contact alarm output for lights and power • Both NO and NC alarm contacts are available • Overvoltage protection and MOV surge protection • Circuit breaker protection and fuse protection Specifications Parameter Input Voltage • • Power consumption 10W Flash rate Steady-Burning/40FPM(default) Photocell sensitivity 70/100Lux Operating temperature range -30℃~+60℃ Enclosure Aluminum alloy Protection class IP67 Dimension(HxWxDepth) 320x219x104mm Weight 3.9kg 85-265VAC, 50/60HZ 48VDC • 24VDC © Copyright 2011 Reddot Electronics Co., Ltd 44 www.reddotsignal.com CTR04-B20 Obstruction Light Control Box Based on CTR04B, CTR04-B20 control box is designed with backup battery, which can support REDDOT OL32 double obstruction light(Service+Standby) 20 hours of autonomy once the main power supply fails. Features MECHANICAL • Built-in transfer relay for OL32 double light(service+standby) • LED indicator for lights, power, photocell operation status • Dry contact alarm output for light, power and battery • Both NO and NC alarm contacts are available • Surge protection for both input and output • Transient overvoltage protection and over-discharge protection Application • For Double Obstruction light system Specifications Description Parameter Input voltage 85-265VAC, 50/60Hz Output voltage 48VDC Backup time with REDDOT light 20 hours 1 OL32 double light (Service+Standby) Flash rate Steady-Burning/40FPM(default) Photocell sensitivity 70/100Lux Operating temperature range -30℃~+60℃ Enclosure Cold-Rolled steel sheet, Ral-7035 Electrostatic Polyester Protection class IP65 Dimension(HxWxDepth) 500x400x208mm Weight 32kg 20 hours 1 OL32 double light (Service+Standby) • PHC01 Photocell • OL32D Double Light © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 45 CTR04-AIDO Control box CTR04-AIDO is specially designed for voltage AC input and DC output outdoor controller installation, to control and monitor aviation obstruction lighting system. CTR04-AIDO control box employs MCU IC control technology. With a pre-programmed software, control up to 4 ways aviation obstruction lights. In case of any medium intensity beacon or any level of low intensity sidelights failure, will send alarm signal to the controller and then output to remote monitoring system. A photocell is deployed within the controller system, which can turn on/off the system from dusk to dawn automatically, easy for maintenance and trouble shooting. Once the photocell fails, all lights in the system will be on in a safe status. Features • Designed for AC100-240V input voltage and DC48V output obstruction lighting system • Control up to three medium intensity beacons and 1 level of up to 4 units of low intensity single obstruction lights, also suitable for only single or double obstruction lighting system. • Dry contact alarm relay for power supply, flasher, beacon, markers, photocell • LED indicators in control board to indicate lights, power, photocell operation status • Alarm relay for each sidelight level • Alarm relay for each beacon • Auto/manual mode control switch • Alarm signal output, easy for connecting remote alarm monitoring device • Combined with REDDOT PHC01photocell, which can turn on/off the system from dusk to dawn • Surge protedtor for input and output Specifications Description Parameter Input power voltage 100-240VAC(50/60HZ) Output operation voltage 48VDC Surge protector 65KA/2.5KV Protection class IP65 Material (Two options) Cold-Rolled steel sheet, Ral-7035 Electrostatic Polyester Operating temperature -30C°-+60C° Photocell sensitivity 30/70Lux Dimension 400mm*300mm*150mm Weight 8KG Cold-Rolled steel sheet • Inside view © Copyright 2011 Reddot Electronics Co., Ltd 46 www.reddotsignal.com • PHC01 Photocell • OL32D Double Light Typical System Application T45-D T45-2S T90-XMYS H≤45M OL32D H≤45M OL32S OM2B-A 45M<H<105M OL32S OL32S JB OL32S OL32S JB BTS Alarm BTS Alarm Power BTS Alarm Power Power Alarm mornitoring in BTS Alarm mornitoring in BTS Alarm mornitoring in BTS 1 double obstruction lighting system 2 single obstruction lighting system • Control one low intensity double light on the top • Under “service+standby” system, configured transfer relay in the control box, in case of service lam failure, will transfer to standby lamp • In “Service+service”type, either failure will output signal to the control box • Control two low intensity single lightson the top • Under “service+standby” system, configured transfer relay in the control box, in case of service lam failure, will transfer to standby lamp • In “Service+service”type, either failure will output signal to the control box 1 medium intensity beacon+3 or 4 single low intensity obstruction lights • One medium intensity light on the top and 3 or 4 single low intensity light on 1/2 or 2/3 height of tower • Alarm output for each medium intensity beacon • Alarm output for each low intensity level Wiring method Please connect the power cord according to the label instruction 1 2 3 N 4 L 5 NULL Poewr 6 N 7 L 8 N Lamp1 L 9 10 NULL 11 N Lamp2 L Lamp3 12 N 13 L 15 Com NC Lamp1 Alarm 16 17 18 Com NC Com 19 20 21 NC Com NC 22 Com Lamp2 Alarm Lamp3 Alarm Lamp4 Alarm Power 23 AL:4 NO:3 AL:3 NO:2 AL:2 AL:1 NO:1 Charging Power Power off Auto Operation Lamp4 Photocell - photocell control terminal “Power” - controller power input Lamp1, Lamp2, Lamp3, Lamp4 - connect to aviation obstruction light separately 14 NO:4 24 25 NULL NO:1, NO:2, NO:3, NO:4 are 4 aviation obstruction light indicators individully. 26 Green light means working fine. Red light AL1, AL2, AL3, AL4 means corresponding light has failed. NC Alarm Photocell Lamp1 Alarm, Lamp2 Alarm, Lamp3 Alarm, Lamp4 Alarm output alarm terminal • Please make sure all wiring job are correct. Connecting the power supply, then the controller will start to work © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 47 Aviation Obstruction Light Other • • • • OMARK Obstruction Marking Sphere Installation Accessories • Installation & Commissioning Accessories for Aviation Obstruction Lighting System http://www.reddotsignal.com/en/products/aviation/ OMARK Obstruction Marking Sphere Aviation obstruction marking sphere is designed to provide daytime visual warning of electricity transmission line for aircraft pilots, especially cross river high voltage transmission lines. A marker should be of one colour. When installed, white and red, or white and orange markers should be displayed alternately. The colour selected should contrast with the background against which it will be seen. Functions&Features • • • • • • • • Not easy to break during transportation & installation Super corrosion resistant character, stainless steel bolts and nuts Aluminum alloy cable clamp guarantees good corrosion resistance Various size of cable clamps are available to fit into customers’ cable conductor Drain holes structure can prevent accumulated rain water inside the spheres Stacking compatible design, save storage space and freight charge Optional Preformed Armor Rods prevent the spheres slipping from the conductor Optional Reflective strip for night visibility Application • Power transmission Line Standard • ICAO Annex 14, 4th Edition, July 2004 • FAA AC 70/7460-1K, obstruction Marking and Lighting © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 48 Specifications Operation Visible Distance 1200 meters Voltage Range 35KV-1000KV Conductor diameter 6.5-55mm .0 Ø600 Mechanical structure Color Orange, Red, White, Orange/White, Red/White Sphere body FRP(Fiberglass Reinforced Polyester) Cable clamp Aluminum alloy Bolts/nuts/washers Stainless steel 304 Diameter 600mm Weight 6.9KG Thickness 3mm Drain holes Yes Optional • 150 700 Preformed Armor Rods • Reflective Strip Warranty 2 Years Ordering Code Series Diameter Color OMARK 600mm O(Orange) Cable diameter(mm) ___.___ Armor Rods AR Reflective Strip RS R(Red) W(White) O/W(Orange/White) R/W(Red/White) or Example, OMARK600O13.1AR means a 600mm diameter warning sphere, orange color, with preformed armor rods, suitable for diameter 13.1mm cable conductor. Note : For guarantee the spheres can fit for cable conductor well, customers need to provide cable diameter, cable material and code. © Copyright 2011 Reddot Electronics Co., Ltd 49 www.reddotsignal.com Installation Accessories Single light mounting kit parts list Ref No DESCRIPTION 1 Single lamp 2 Gasket 3 Fixed board 6mm washer 4 5 6mm spring washer M6 hex nut 6 7 3/4"joint 8 Cable waterproof joint (PG13.5) 10 1 11 2 12 3 13 4 5 6 15 7 8 16 9 Pipe diameter range 30-80 mm AKU80 Mounting kit for 30-80mm vertical or horizonal pipe Ordering Code: AKU80 Pipe diameter range 30-60 mm AKU60 Mounting kit for 30-60mm vertical pipe Ordering Code: AKU60 14 9 10 11 12 13 14 15 16 M8 hex nut M6 × 25 hex bolt Support clip 8mm spring washer 8mm washer M8 U-bolt M6 Trapezoidal card Pipe MATERIAL Silicon SUS #304 SUS #304 SUS #304 SUS #304 SUS #304 PA66 SUS #304 SUS #304 SUS #304 SUS #304 SUS #304 SUS #304 SUS #304 QUANTITY 1 1 1 2 2 2 1 1 4 1 1 4 4 1 1 1 Pipe diameter range 60-100 mm AKU100 Mounting kit for 60-100mm vertical l pipe Ordering Code: AKU100 Pipe diameter range 100-150 mm AKU150 Mounting kit for 100-150mm vertical pipe Ordering Code: AKU150 © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 50 © Copyright 2011 Reddot Electronics Co., Ltd 51 www.reddotsignal.com Installation & Commissioning Assembly & wiring diagram Single light Wiring Diagram 4 To Control box 3 2 5 TB1-1 TB1-2 TB1- 3 TB1- 4TB1- 5 TB1 1 IF DC NO DC12V~60V COM IF AC AC85V~265V L NOTE:The part within dotted line is only applicable when the light comes with "alarm relay" optional function N Single lamp explosion figure Ref No DESCRIPTION No.Requ'd 1 2 Base 3 Bolt components M6 x 30 1 1 3 Safety rope 4 Lamp-chimney 5 Control Board Power Cord Figure 2. Single light assembly & wiring diagram 1 1 Double light CN1 1 3 CN5 CN5-4: + CN5-3: - CN1-4: COM COM CN1-3: NO NO CN1-2: L + N - CN1-1: 5 L N CN5-2: NO NO CN5-1: COM COM 4 IF IF DC AC IF IF AC DC 2 Wiring Diagram 5 To Control box 1 TB1 Double lamp explosion figure Ref No DESCRIPTION No.Requ'd 1 2 "Working" Light Terminal Single lamp Bolt components M5x 10 1 1 4 Cover "Stand-by" Light Terminal 1 1 3 4 5 IF DC IF AC TB1-1 TB1-2 TB1- 3 TB1- 4TB1- 5 DC12V~60V L NOTE:The part within dotted line is only applicable when the light comes with "alarm relay" optional function COM NO N AC85V~265V Figure 3. Double light assembly & wiring diagram © Copyright 2011 Reddot Electronics Co., Ltd www.reddotsignal.com 52 Accessories for Aviation Obstruction Lighting System © Copyright 2011 Reddot Electronics Co., Ltd 53 www.reddotsignal.com ghai Red an ANTY WARR Y POLIC Sh Warranty Policy Co., Ltd ics t Electron do REDDOT products are warranted to be free from manufacturing defects in materials and workmanship starting from the date of delivery. The actual warranty period of the product depends on the product category. Limitation of Liability The provisions of the warranty are in lieu of any other warranty, whether expressed or implied, written or oral. REDDOT's liability arising out of the manufacture, sale, or supplying of the product and its use, whether based on warranty, contract, negligence, product liability, or otherwise, shall not exceed the original cost of the product. In no event shall REDDOT be liable for unintended or consequential damages, including, but not limited to, a loss of profits or use damages arising out of the manufacture, sale, or supplying of the product. Replacement • Due to the high rate of international air transportation and custom clearance paper works, we may not require customers to return products as long as the customer could provide enough materials of the incorrect product. In that case, REDDOT will send out replacement product once our QC approved the application. • Before returning a REDDOT product, please provide information like model, quantity, your region, and product photo or situation statement of the product in order to get quicker service. Please contact [email protected], or contact with individual sales person. Warranty Periods Products Category Warranty Period Light & control device 5 Years Solar panel 10 Years Rechargeable battery 2 Years Accessory 1 Years Note • Please make sure connect the product according to the wiring diagram on the category. • For products containing rechargeable battery, REDDOT normally give 2 years warranty on the battery unless there is specific stating on the product’s category. • For products containing solar panel & rechargeable battery, the battery’s power may reduce to insufficient level during storage and transit. In this case, please first put the product under sunlight at daytime for several days for battery charging purpose. • Product warranties remain valid provided the product was properly installed and used. Defects, malfunctions, or failures of the warranted product caused by damage resulting from acts of God (such as floods, fire, etc.), environmental and atmospheric disturbances, other external forces such as power line disturbances, host computer malfunction, plugging the board in under power, or incorrect cabling, and damage caused by misuse, abuse, and unauthorized alteration or repair, are not warranted. • For large order projects, customers may purchase an extended maintenance contract. Some parts may have a limited warranty from the original supplier of the parts. Please contact Reddot's sales department if you would like to extend the maintenance period of a REDDOT product. For customers Thank you for taking the time to read our products! If you are interested on any REDDOT product, please don’t hesitate to contact us. Our sales people will come back to you at first time. For better understanding for the right product you are looking for, or the type of solution you will need, we recommend that you state your situation as much as possible, for example : • Which industry the product will be applied to, telecom industry, tall building, etc • Which position the product will be applied to, a 60 meters telecom tower, etc • Any key functions must be included in the product, relay type alarm output, etc • Any special industrial regulations that must be followed, Transport Canada rules, Australia CASA rules, etc • Others like the region you are from, your project budget, your project dead-line, etc In some region, we have distributor already. In such case, we will forward your request to our distributor. Our distributor can support you better locally. Any other questions please don’t hesitate to contact us, we will be more than happy to assist! For distributors REDDOT welcome distributors that have expertise knowledge to sell our product. If you are interested on distributing REDDOT product in your region, please send email to us for further discussion. You can state your interest, together with background information like: • Concentrating industry • Interested areas • Interested products • preferred commercial terms, etc REDDOT Sales Contact Distributor Contact