HE A combi, system and heat only boilers
Transcription
HE A combi, system and heat only boilers
HE A combi, system and heat only boilers Range guide Introduction A brand you can trust 2 Baxi make it easy 3 Baxi Platinum Combi HE A A brand you can trust Baxi make it easy Features and benefits 6-7 What’s inside the boiler? 8 Flues 9 We are so confident in the reliability of our boilers that we provide industry-leading warranties, providing peace of mind for you and your customers. And our warranty terms and conditions have been approved by the Plain English Campaign so they are easy to understand. 1935 14 Flues 15 page 16 Technical specifications 18-19 What’s inside the boiler? 20 Flues 21 Baxi Solo Heat Only HE A Features and benefits 1955 Philip Baxendale, Richard’s great-grandson, becomes General Manager as Baxi becomes a household name 1966 Baxi develops a warm-air central heating technology fuelled by gas What’s inside the boiler? Features and benefits Warranty An underfloor draught system for solid fuel heating is launched – the first product bearing the Baxi name 1963 12-13 Accessories17 1866 Iron moulder Richard Baxendale opens the doors of his new company 10 Technical specifications Baxi Megaflo System HE A Every Baxi boiler has to pass a full function test using gas, water and electricity, before it leaves the production line. A brief history of Baxi page Accessories11 Reliability *According to independent research. 4 Technical specifications Baxi Duo-tec Combi HE A We are committed to making your experience with Baxi as easy as possible.. We continue to invest in the business to provide reliable, energy efficient heating and hot water, backed by industry-leading customer support, nationwide availability of parts and training. page Accessories5 Features and benefits Baxi has been manufacturing in the UK for nearly 150 years. It has a heritage of providing cutting edge heating products for homes and is the best known boiler manufacturer amongst homeowners*. page Baxi launches its most famous product: the Bermuda gas-fired back boiler 1983 Efficiency Technical specifications 24-25 All Baxi boilers are Energy Saving Trust recommended, helping households to save money on their gas bills. What’s inside the boiler? 26 Flues 27 Baxi Bermuda BBU HE Features and benefits We are there for you – providing practical training, technical help and genuine parts – when you need us. 2001 A period of acquisitions sees Baxi purchasing Ocean Idroclima and the Blue Circle Heating Division The Baxi 105 E becomes the UK’s biggest-selling combi boiler 2006 page 28 Accessories29 The Baxi Solo – a low-weight cast iron boiler – is launched 1999 22 Accessories23 Support 1989 Baxi is sold to its workforce, becoming the UK’s largest employee partnership of its kind page Easy to install Our boilers come with a pre-plumbing jig, complete with preformed copper pipe tails, built-in filling loop and one metre mains cable to save you time and money during installation. The award-winning Baxi Duo-tec Combi HE is launched 2010 The UK’s first domestic, wall-hung micro-CHP appliance, Baxi Ecogen, is launched 2012 Technical specifications 30-31 What’s inside the boiler? 32 Flues 33 Flue solutions page Vertical flue systems 34-35 Horizontal flue systems 35-36 Plume displacement kits 36 Twin flue systems 37 Baxi Bermuda BBU HE 37 Additional services Baxi Ecogen wins the Queen’s Award for Enterprise in Innovation How we can help page 3 page 38-39 I regularly recommend the Platinum HE A. The 10 year warranty means customers trust the product and I know that it won’t let them down. Simon Harrington Harrington Plumbing & Heating Baxi Platinum Combi HE A The Baxi Platinum Combi HE A is our top of the range boiler. A firm favourite with householders and installers alike, it’s an Energy Saving Trust recommended product, so you can be sure of its excellent energy efficiency. Total peace of mind The Baxi Platinum Combi HE A comes with an impressive 10 year warranty*. Accessories The following accessories are compatible with the Baxi Platinum Combi HE A 10 yr WARRANTY* page 5 BUILT-IN TIMER BUILT-IN FILLING LOOP EXTENSIVE FLUE OPTIONS Key features Benefits Outputs: 24kW, 28kW, 33kW and 40kW A model to suit most styles and sizes of property Pre-plumbing jig, with built-in filling loop and preformed copper tails Easy to install and maintain, saving time and money Built-in mechanical 24 hour timer Easy to set and control Built-in frost thermostat Suitable for siting in garages and lofts Front access to all components Easy to service and maintain Exceptional flow rate (up to 16.4 litres per minute) at a rise of 35ºC Ideal for homes with more than one bathroom Compatible with Multifit flue kits Industry-leading choice of lengths, bends and accessories page 6 Baxi qSense digital room thermostat Baxi programmable 24 hour wireless sensor Baxi seven day programmable room thermostat Baxi room thermostat Baxi wired weather sensor Multifit GasSaver GS1 *Subject to registration and an annual service. Available until 31st December 2014. Terms and conditions apply. For full details visit baxi.co.uk/warranty Technical details Baxi Platinum Combi HE A Technical specifications Baxi Platinum Combi HE A HOW WE MAKE IT EASY Sales code Pre-plumbing jig for quick and simple installation. Controls Concealed user controls On/off switch with reset User adjustable DHW temperature User adjustable CH temperature LED temp/status/fault diagnosis display Integral 24 hour electro-mechanical timer 24 HE A 28 HE A 33 HE A 40 HE A 5116062 5116203 5116205 5121682 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 digits/3 LEDs 2 digits/3 LEDs 2 digits/3 LEDs 2 digits/3 LEDs Fitted as standard Fitted as standard Fitted as standard Fitted as standard 22 22 22 22 3 3 3 3 20 20 20 Gas A D Boiler dimensions E D Gas supply pipe size Natural gas mm Nominal inlet supply pressure Maximum gas rate Heat input central heating mbar 20 m3/hr 2.61 3.10 3.6 4.36 kW max gross 22.7 27.4 32.1 36.4 kW max net 20.5 24.7 28.9 32.8 kW min gross 7.8 10.0 10.8 11.0 kW min net 7.0 9.0 9.7 9.9 Heat output CH non condensing (70° mean water temp) kW max 20 24 28 32 kW min 6.8 8.7 9.4 9.6 Heat output CH condensing (40° mean water temp) kW max 21.0 25.9 30.3 34.4 kW min 7.4 9.5 10.2 12.1 Heat input domestic hot water (DHW) kW max gross 27.4 32.1 37.7 45.7 kW max net 24.7 28.9 34 .0 41.2 Heat output domestic hot water Maximum domestic hot water flow rate Seasonal efficiency SEDBUK (2005) rating NOx class kW max 24 28 33 40 l/min @ 35°C rise 9.8 11.5 13.5 16.4 91.1 91.1 91.1 91.1 A A A A 5 5 5 5 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz 3 3 3 3 A Boiler width = 450mm height Height [B]B Boiler Depth [C] = 780mm C Boiler depth = 345mm 450mm780mm 345mm = 5mm* D Side clearance E Upper clearance = 200mm* (300mm* if using 80/125mm flueing system) F Lower clearance = 150mm* G Front clearance = 5mm* in operation, 450mm* for servicing purposes Side [D] Upper [E] Lower [F] Front [G] Width [A] Service clearances 5mm*200mm* (*300 if using B G 150mm* 5mm in operation*, % Electrical Electrical supply Permanent live required 80/125 flueing *450 for servicing system) purposes Volts/Hz Fitted electrical cable Power consumption External fuse rating Internal fuse rating Ingress protection rating (without electro-mechanical timer fitted) 24 hour pump exercise These are the minimum recommended dimensions. Greater clearance will aid installation and maintenance. * * These are the MINIMUM recommended dimensions. Greater clearance will aid installation and maintenance. 1m x 3 core x 0.75mm2 on all models Watts 155 155 160 Amps 3 3 3 3 Amps F2L F2L F2L F2L IPX 5D IPX 5D IPX 5D IPX 5D 3 3 3 3 3 3 3 3 3 3 3 3 None None None None 3 3 3 3 Pump overrun Integral ‘boiler only’ frost thermostat C F 160 Mechanical and hydraulic Compartment ventilation requirement Pre-plumbing/wall mounting jig What’s in the box? Flow and return pipe size Condensate discharge pipe size Integral automatic bypass mm 22 22 22 22 mm 21.5 21.5 21.5 21.5 3 3 3 3 Min domestic hot water flow rate Min domestic hot water operating pressure Maximum DHW system pressure Safety discharge pressure Integral expansion vessel capacity Max capacity of central heating system Temporary filling loop included l/min 2 2 2 2 bar 0.15 0.15 0.15 0.15 bar 8 8 8 8 bar 3 3 3 3 litres 8 8 10 10 litres 125 125 155 155 3 3 3 3 3 3 3 3 315 - 500 CH system inhibitor required Concentric flue system Standard telescopic horizontal flue kit length Max equiv length horizontal/vertical (60/100mm) Max equiv length horizontal/vertical (80/125mm) Equivalent length per 135º bend Equivalent length per 93º bend Platinum Combi HE A boiler Pre-plumbing jig Fitting instructions, template, user instructions, warranty Filling loop Copper pipe tails mm 315 - 500 315 - 500 315 - 500 m 10 10 10 10 m 20 20 20 20 m 0.5 0.5 0.5 0.5 m 1 1 1 1 mm 80/80 80/80 80/80 80/80 m 15/15 15/15 15/15 15/15 m 0.25 0.25 0.25 0.25 m 0.5 0.5 0.5 0.5 kg 43.6 44.2 45 45 kg 48.6 49.2 50 50 Twin pipe flue system Diameters Max equiv length horizontal/vertical (parallel pipes) Equivalent length per 135° bend Equivalent length per 91.5° Bend Weights Max installation lift weight Gross packaged boiler weight page 7 page 8 What’s inside the boiler? Flues Baxi Platinum Combi HE A These are the flues that are most frequently installed with the Baxi Platinum Combi HE A. For the full range, see pages 34-37. Horizontal flue system Flue connection GROUP A | Concentric horizontal flue system | 60/100mm diameter Igniter Key Expansion vessel Spark electrode Combustion box cover and burner Stainless steel heat exchanger Flame sensing electrode Item description Specification OD dimensions Multifit sales code Standard horizontal telescopic flue (inc elbow) 315mm - 500mm 60/100mm 5118069 Standard horizontal flue (inc elbow) 685mm 60/100mm 5118489 Flue extension 1000mm 100mm 5111074 Flue bend 93º 100mm 5111075 Flue bend (pair) 135º 100mm 5111085 NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in accordance with the installation instructions. Air/gas collector Fan assembly Vertical flue system Venturi GROUP A | Concentric vertical flue system | 60/100mm diameter Condensate trap (behind) Key Item description Specification Gas valve Vertical flue terminal Pump PCB housing Diverter valve (behind) OD dimensions Multifit sales code 100mm 5118576 Flue extension 1000mm 100mm 5111074 Flue bend 93º 100mm 5111075 Flue bend (pair) 135º 100mm 5111085 Pressure relief valve *Pitched roof and flat roof flashing available – see page 34 Pressure gauge Integral clock Plume displacement kits GROUP K | Plume displacement kits | 60/100mm diameter Key HOW WE MAKE IT EASY Multifit flue kits offer an industry-leading choice of accessories. page 9 Item description Specification Plume displacement kit (inc elbow and clips) 100mm Plume displacement kit (extension inc clip) 1000mm OD dimensions Multifit sales code 5118638 60mm 5121368 page 10 I regularly specify the Duo-tec HE A boiler. It is easy for my customers to use with its clear display and large symbols. It has always been extremely reliable and the seven year warranty is brilliant. Mark Webley Webley Heating Baxi Duo-tec Combi HE A Our best selling Baxi Duo-tec Combi HE A has a pre-plumbing jig, complete with preformed copper pipe tails, built-in filling loop and one metre mains cable, making it quick and easy to install. Total peace of mind The Baxi Duo-tec Combi HE A has proven reliability, which is why it comes with a 7 year warranty*. Accessories The following accessories are compatible with the Baxi Duo-tec Combi HE A. 7 yr WARRANTY* COMPACT CASE DIMENSIONS BUILT-IN FILLING LOOP LPG MODEL AVAILABLE Baxi qSense digital room thermostat page 11 Key features Benefits Outputs: 24kW, 28kW, 33kW and 40kW A model to suit most styles and sizes of property Pre-plumbing jig, with built-in filling loop Easy to install and maintain Built-in frost thermostat Suitable for siting in garages and lofts Class leading flow rate (up to 16.4 litres per minute) at 35°C rise Perfect for homes with more than one bathroom Dedicated 28kW LPG model Suitable for homes without mains gas Telescopic horizontal flue available Quick and easy to fit Compatible with Multifit flue kits Industry-leading choice of lengths, bends, accessories Baxi electromechanical 24 hour timer kit Multifit GasSaver GS1 Baxi room thermostat *Subject to registration and an annual service. Available until 31st December 2014. Terms and conditions apply. For full details visit baxi.co.uk/warranty page 12 Technical details Baxi Duo-tec Combi HE A Technical specifications Baxi Duo-tec Combi HE A HOW WE MAKE IT EASY Sales Code Pre-plumbing jig for quick and simple installation. 24 HE A 28 HE A 33 HE A 40 HE A 5118060 5118646 5118062 5121342 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 digits/3 LEDs 2 digits/3 LEDs 2 digits/3 LEDs 2 digits/3 LEDs 22 22 22 22 3 3 3 3 N/A 3 N/A N/A Controls Concealed user controls On/off switch with reset User adjustable DHW temperature User adjustable CH temperature LED temp/status/fault diagnosis display Gas Gas supply pipe size mm Natural gas LPG (propane) A D Boiler dimensions E D A Boiler width = 450mm height = 780mm Width [A] Height [B]B Boiler Depth [C] C Boiler depth = 345mm 450mm780mm 345mm = 5mm* D Side clearance E Upper clearance = 200mm* (300mm* if using 80/125mm flueing system) F Lower clearance = 150mm* G Front clearance = 5mm* in operation, 450mm* for servicing purposes Upper [E] Lower [F] Front [G] Service clearances Side [D] 5mm*200mm* (*300 if using B mbar 20 20 20 20 Maximum gas rate NG m3/hr 2.61 3.10 3.6 4.36 Heat input central heating kW max gross 22.7 27.4 32.1 36.4 kW max net 20.5 24.7 28.9 32.8 kW min gross 7.8 10 .0 10.8 11.0 kW min net 7.0 9.0 9.7 9.9 Heat output CH non condensing kW max 20 24 28 32 (70° mean water temp) kW min 6.8 8.7 9.4 9.6 Heat output CH condensing kW max 21.0 25.9 30.3 34.4 (40° mean water temp) kW min 7.4 9.5 10.2 12.1 Heat input domestic hot water kW max gross 27.4 32.1 37.7 45.7 (DHW) kW max net 24.7 28.9 34.0 41.2 Heat output domestic hot water kW max 24 28 33 40 Maximum domestic hot water flow rate l/min @ 35°c rise 9.8 11.5 13.5 16.4 Seasonal efficiency NG % 91.1 91.1 91.1 91.1 SEDBUK (2005) rating Band A A A A 5 5 5 5 mg/kWhr 22.3 26.0 21.8 25.2 Volts/Hz 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz 3 3 3 3 NOx Class G 150mm* 5mm in operation*, Nominal inlet supply pressure NG NOx levels Electrical 80/125 flueing *450 for servicing system) purposes Electrical supply Permanent live required Fitted electrical cable These are the minimum recommended dimensions. Greater clearance will aid installation and maintenance. * * These are the MINIMUM recommended dimensions. Greater clearance will aid installation and maintenance. 1m x 3 core x 0.75mm2 on all models Power consumption Watts 155 155 160 External fuse rating Amps 3 3 3 3 Internal fuse rating Amps F2L F2L F2L F2L IPX 5D IPX 5D IPX 5D IPX 5D 3 3 3 3 3 3 3 3 3 3 3 3 None None None None 3 3 3 3 Ingress protection rating (without electro-mechanical timer fitted) 24 hour pump exercise Pump overrun Integral ‘boiler only’ frost thermostat C F 160 Mechanical and hydraulic Compartment ventilation requirement What’s in the box? Pre-plumbing/wall mounting jig Flow and return pipe size mm 22 22 22 22 Condensate discharge pipe size mm 21.5 21.5 21.5 21.5 3 3 3 3 2 2 2 2 Integral automatic bypass Min domestic hot water flow rate l/min Min domestic hot water operating pressure bar 0.15 0.15 0.15 0.15 Maximum DHW system pressure bar 8 8 8 8 Safety discharge pressure bar 3 3 3 3 Integral expansion vessel capacity litres 8 8 10 10 Max capacity of central heating system litres 125 125 155 155 3 3 3 3 3 3 3 3 315 - 500 Filling loop included CH system inhibitor required Concentric Flue System Duo-tec Combi HE A boiler Pre-plumbing jig Fitting instructions, template, user instructions, warranty Filling loop Copper pipe tails Standard telescopic horizontal flue kit length mm 315 - 500 315 - 500 315 - 500 Max equiv length horizontal/vertical (60/100mm) m 10 10 10 10 Max equiv length horizontal/vertical (80/125mm) m 20 20 20 20 Equivalent length per 135º bend m 0.5 0.5 0.5 0.5 Equivalent length per 93º bend m 1 1 1 1 Twin pipe flue system Diameters mm 80/80 80/80 80/80 80/80 Max equiv length horizontal/vertical (parallel pipes) m 15/15 15/15 15/15 15/15 Equivalent length per 135° bend m 0.25 0.25 0.25 0.25 Equivalent length per 91.5° Bend m 0.5 0.5 0.5 0.5 Weights page 13 Max installation lift weight kg 43.6 44.2 46 46 Gross packaged boiler weight kg 48.6 49.2 51 51 page 14 What’s inside the boiler? Flues Baxi Duo-tec Combi HE A These are the flues that are most frequently installed with the Baxi Duo-tec Combi HE A. For the full range, see pages 34-37. Horizontal flue system GROUP A | Concentric horizontal flue system | 60/100mm diameter Igniter Key Expansion vessel Spark electrode Combustion box cover and burner Stainless steel heat exchanger Flame sensing electrode Item description Specification OD dimensions Multifit sales code Standard horizontal telescopic flue (inc elbow) 315mm - 500mm 60/100mm 5118069 Standard horizontal flue (inc elbow) 685mm 60/100mm 5118489 Flue extension 1000mm 100mm 5111074 Flue bend 93º 100mm 5111075 Flue bend (pair) 135º 100mm 5111085 NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in accordance with the installation instructions. Air/gas collector Vertical flue system Venturi GROUP A | Concentric vertical flue system | 60/100mm diameter Condensate trap (behind) Key Item description Specification Vertical flue terminal Pump OD dimensions Multifit sales code 100mm 5118576 Flue extension 1000mm 100mm 5111074 Flue bend 93º 100mm 5111075 Flue bend (pair) 135º 100mm 5111085 Pressure relief valve *Pitched roof and flat roof flashing available – see page 34 Plume displacement kits GROUP K | Plume displacement kits | 60/100mm diameter Key HOW WE MAKE IT EASY Telescopic horizontal flue option is quick and easy to fit. page 15 Item description Specification Plume displacement kit (inc elbow and clips) 100mm Plume displacement kit (extension inc clip) 1000mm OD dimensions Multifit sales code 5118638 60mm 5121368 page 16 I regularly install the Megaflo HE A boiler. It is a great boiler, easy to work on and good value for money. Jack Sowden Royston Engineering Baxi Megaflo System HE A Designed for fully pumped sealed systems, the Baxi Megaflo System HE A can be installed with an unvented cylinder. It will satisfy the hot water and heating requirements of most homes, including larger properties with more than one bathroom. Total peace of mind The Baxi Megaflo System HE A has proven reliability, which is why it comes with a 7 year warranty*. Accessories The following accessories are compatible with the Baxi Megaflo System HE A 7 yr WARRANTY* page 17 FULLY MODULATING OUTPUTS PRE-PLUMBING JIG SUPPLIED INTEGRAL AUTOMATIC BYPASS Key features Benefits Outputs: 15kW, 18kW, 24kW, 28kW and 32kW A model to suit most styles and sizes of property Pre-plumbing jig, with built-in filling loop Easy to install and maintain Easy to use built-in timer Easy to set and control Built-in frost thermostat Suitable for siting in garages and lofts Integral automatic bypass Suitable for systems with TVRs on every radiator Compatible with Multifit flue kits Industry-leading choice of lengths, bends, accessories Compatible with the market-leading Megaflo cylinders Made by our sister company Heatrae Sadia Suitable for use with Baxi Solarflo solar thermal Hot water from solar energy reduces energy bills Megaflo Eco unvented cylinder Baxi Solarflo *Subject to registration and an annual service. Available until 31st December 2014. Terms and conditions apply. For full details visit baxi.co.uk/warranty page 18 Technical details Baxi Megaflo System HE A Technical specifications HOW WE MAKE IT EASY Front access to all components makes servicing simple. Baxi Megaflo System HE A 15 HE A 18 HE A 24HE A 28 HE A 32 HE A Sales code Concealed user controls On/off switch with reset User adjustable CH temperature Boiler dimensions E E Upper clearance = 200mm* (300mm* if using 80/125mm flueing system) F Lower clearance = 200mm* G Front clearance = 5mm* in operation, 450mm* for servicing purposes Upper [E] Lower [F] Front [G] Side [D] 5mm*200mm* (*300 if using 5121345 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 22 2 digits/3 LEDs on all models mm 22 22 22 22 3 3 3 3 3 20 20 20 20 mbar 20 Maximum gas rate NG m3/hr 1.69 1.95 2.61 3.10 3.48 Heat input central heating kW max gross 17.1 20.5 27.4 32.1 36.4 kW max net 15.4 18.5 24.7 28.9 32.8 kW min gross 4.4 4.8 7.8 10.8 10.8 kW min net 4.0 4.3 7.0 9.7 9.7 kW max 15 18 24 28 32 kW min 3.9 4.2 6.8 9.4 9.4 Heat output CH condensing (40° mean water temp) kW max 16.2 19.4 25.9 30.3 34.4 kW min 4.2 4.5 7.4 10.2 10.2 Seasonal efficiency % 91.2 91.2 91.2 91.2 91.2 SEDBUK (2005) rating A A A A A NOx class 5 5 5 5 5 mg/kWhr 27.5 31.7 22.3 21.8 26.8 Volts/Hz 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz 3 3 3 3 3 160 Heat output CH non condensing (70° Mean Water temp) Service clearances 5118648 Nominal inlet supply pressure D A Boiler width = 450mm B Boiler height = 780mm Width [A] Height [B] Depth [C] C Boiler depth = 345mm 450mm780mm 345mm = 5mm* D Side clearance 5118063 Gas Natural gas D 5121344 LED temp/status/fault diagnosis display Gas supply pipe size A 5121343 Controls NOx levels Electrical B Electrical supply Permanent live required G 150mm* 5mm in operation*, Fitted electrical cable 80/125 flueing *450 for servicing system) purposes 1m x 3 core x 0.75mm2 on all models Power consumption Watts 130 140 150 160 External fuse rating Amps 3 3 3 3 3 Internal fuse rating Amps F2L F2L F2L F2L F2L IPX 5D IPX 5D IPX 5D IPX 5D IPX 5D 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 None None None None None 3 3 3 3 3 Ingress protection rating (without electro-mechanical timer fitted) These are the minimum recommended dimensions. Greater clearance will aid installation and maintenance. * 24 hour pump exercise * These are the MINIMUM recommended dimensions. Greater clearance will aid installation and maintenance. Pump overrun Integral ‘boiler only’ frost thermostat Mechanical and hydraulic C F What’s in the box? Compartment ventilation requirement Pre-plumbing/wall mounting jig Flow and return pipe size mm 22 22 22 22 22 Condensate discharge pipe size mm 21.5 21.5 21.5 21.5 21.5 3 3 3 3 3 Integral automatic bypass Safety discharge pressure bar 3 3 3 3 3 Integral expansion vessel litres 8 8 8 10 10 Max capacity of central heating system litres 125 125 125 125 125 3 3 3 3 3 315 - 500 CH system inhibitor required Concentric Flue System Standard telescopic horizontal flue kit length mm 315 - 500 315 - 500 315 - 500 315 - 500 Max equiv length horizontal/vertical (60/100mm) m 10 10 10 10 10 Max equiv length horizontal/vertical (80/125mm) m 20 20 20 20 20 Equivalent length per 135º bend m 0.5 0.5 0.5 0.5 0.5 Equivalent length per 93º bend m 1 1 1 1 1 Twin pipe flue system Diameters mm 80/80 80/80 80/80 80/80 80/80 Max equiv length horizontal/vertical (parallel pipes) m 15/15 15/15 15/15 15/15 15/15 Equivalent length per 135° bend m 0.25 0.25 0.25 0.25 0.25 Equivalent length per 91.5° Bend m 0.5 0.5 0.5 0.5 0.5 Max installation lift weight kg 38.6 38.6 39.2 41 41 Gross packaged boiler weight kg 43.6 43.6 44.2 46 46 Weights Megaflo System HE A boiler page 19 Pre-plumbing jig Fitting instructions, template, user instructions, warranty Copper pipe tails page 20 What’s inside the boiler? Flues Baxi Megaflo System HE A These are the flues that are most frequently installed with the Baxi Megaflo System HE A. For the full range, see pages 34-37. Horizontal flue system GROUP A | Concentric horizontal flue system | 60/100mm diameter Igniter Key Expansion vessel Spark electrode Combustion box cover and burner Stainless steel heat exchanger Flame sensing electrode Item description Specification OD dimensions Multifit sales code Standard horizontal telescopic flue (inc elbow) 315mm - 500mm 60/100mm 5118069 Standard horizontal flue (inc elbow) 685mm 60/100mm 5118489 Flue extension 1000mm 100mm 5111074 Flue bend 93º 100mm 5111075 Flue bend (pair) 135º 100mm 5111085 NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in accordance with the installation instructions. Air/gas collector Fan assembly Vertical flue system Venturi GROUP A | Concentric vertical flue system | 60/100mm diameter Condensate trap (behind) Key Item description Specification Vertical flue terminal Pump Pressure relief valve OD dimensions Multifit sales code 100mm 5118576 Flue extension 1000mm 100mm 5111074 Flue bend 93º 100mm 5111075 Flue bend (pair) 135º 100mm 5111085 *Pitched roof and flat roof flashing available – see page 34 Pressure gauge Plume displacement kits GROUP K | Plume displacement kits | 60/100mm diameter Key HOW WE MAKE IT EASY Telescopic horizontal flue option is quick and easy to fit. page 21 Item description Specification Plume displacement kit (inc elbow and clips) 100mm Plume displacement kit (extension inc clip) 1000mm OD dimensions Multifit sales code 5118638 60mm 5121368 page 22 The Solo HE A is very reliable and the pump overrun is really handy when retrofitting the boiler into an older house. Carl Broadbent Agoura Heating Baxi Solo Heat Only HE A Lightweight and compact enough to fit into a standard kitchen cupboard, the Baxi Solo HE A is so stylish it will fit in with any modern interior. It is an Energy Saving Trust recommended product. Simple controls make it extremely easy to use. Easy to install The Baxi Solo HE A does not need a pump overrun so it can replace an old heat only boiler with minimum disruption to the householder. Accessories The following accessories are compatible with the Baxi Solo HE A 2yr WARRANTY* page 23 COMPACT DESIGN NO PUMP OVERRUN REQUIRED FULLY MODULATING OUTPUTS Key features Benefits Outputs: 12kW, 15kW, 18kW, 24kW and 30kW A model to suit most styles and sizes of property Lightweight and compact Perfect for applications where space is limited Pre-plumbing jig, with built-in filling loop Easy to install and maintain No pump overrun required Installed with minimal disruption to the householder For use on open vented or sealed heating systems Compatible with most existing heating systems Front access to all components Straightforward servicing and maintenance Simple controls Easy to set and control Compatible with Multifit flue kits Industry-leading choice of lengths, bends, accessories Baxi room thermostat Baxi qSense digital room thermostat Baxi Solarflo Megaflo Eco SystemFit Baxi seven day programmable room thermostat * Subject to registration and an annual service. Terms and conditions apply. page 24 Baxi Solo HE A Technical specifications Technical details HOW WE MAKE IT EASY Front access to all components makes servicing simple. Baxi Solo HE A 12 HE A 15 HE A 18 HE A 24 HE A 30 HE A Sales code 5120295 5117783 5120296 5117784 5117785 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 15 15 15 15 15 3 3 3 3 3 20 20 20 2.95 Controls Concealed user controls User adjustable CH temperature LED status/fault diagnosis display Gas Gas supply pipe size A Boiler dimensions E D D A Boiler width = 390mm Depth [C] B Boiler height = 600mm 390mm600mm 298mm C Boiler depth = 298mm D Side clearance = 5mm* E Upper clearance = 200mm* F Lower clearance = 50mm* G Front clearance = 5mm* in operation, for[F] servicingFront purposes Side [D] Upper [E]500mm* Lower [G] Width [A] Height [B] 150mm* 5mm in operation*, Nominal inlet supply pressure mbar 20 20 Maximum gas rate m3/hr 1.34 1.64 1.94 2.31 Heat input central heating kW max gross 13.3 16.9 20.2 24.5 33.8 kW max net 12.0 15.2 18.2 22.1 30.4 30.2 Heat output CH non condensing kW max 11.8 15.2 17.8 22.0 Heat output CH condensing kW max 12.8 16.5 19.3 23.8 32.6 Seasonal efficiency % 90.5 91.3 90.4 90.9 90.9 SEDBUK (2005) rating Band A A A A A 5 5 5 5 5 mg/kWhr 13.1 29.0 11.7 37.0 48.0 Volts/Hz 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz 7 7 7 7 7 80 NOx class NOx levels Service clearances 5mm*200mm* (*300 if using mm Natural gas Electrical Electrical supply Permanent live required Electrical cable required B G 80/125 flueing *450 for servicing system) purposes 1m x 3 core x 0.75mm2 on all models Power consumption Watts 80 80 80 80 External fuse rating Amps 3 3 3 3 3 Internal fuse rating Amps 3.15 3.15 3.15 3.15 3.15 IPX2 IPX2 IPX2 IPX2 IPX2 7 7 7 7 7 7 7 7 7 7 None Ingress protection rating (without electro-mechanical timer fitted) Pump overrun These are the minimum recommended dimensions. Greater clearance will aid installation and maintenance. * Integral ‘boiler only’ frost thermostat Mechanical and hydraulic Compartment ventilation requirement * These are the MINIMUM recommended dimensions. Greater clearance will aid installation and maintenance. None None None None Flow and return pipe size mm 22 22 22 22 22 Condensate discharge pipe connection mm 21.5 21.5 21.5 21.5 21.5 7 7 7 7 7 3 3 Bypass required Vertical pipe route C F What’s in the box? Within case on all models CH system inhibitor required 3 3 3 Concentric flue system Outside diameter mm 110 110 110 110 110 Standard horizontal flue kit length mm 850 850 850 850 850 Max equivalent length horizontal m Max equivalent length vertical m Equivalent length per 135º bend m 0.5 0.5 0.5 0.5 0.5 Equivalent length per 93º bend m 1 1 1 1 1 4 plus terminal on all models 4 plus terminal on all models Twin pipe flue system Diameters mm 80/80 80/80 80/80 80/80 80/80 Max equiv length horizontal (parallel pipes) m 75 75 75 75 75 Max equivalent length vertical (parallel pipes) m 75 75 75 75 75 Equivalent length per 135° bend m 1.3 air and 2.6 flue on all models Equivalent length per 90° bend m 4.8 air and 9.6 flue on all models Weights Solo HE A boiler page 25 Wall mounting plate Fitting instructions, template, user instructions, warranty Max installation lift weight kg 26 26 26 26 26 Gross packaged boiler weight kg 36.2 36.2 36.2 36.2 36.2 Fittings pack page 26 What’s inside the boiler? Flues Baxi Solo HE A These are the flues that are most frequently installed with the Baxi Solo HE A. For the full range, see pages 34-37. Horizontal flue system GROUP B | Concentric horizontal flue system | 70/110mm diameter Return pipe connection (behind) Key Flow switch Flow pipe connection Heat exchanger Wiring terminal Item description Specification OD dimensions Multifit sales code Standard horizontal flue (inc elbow) 850mm 110mm 236921 Flue extension 1000mm 100mm 241695 Flue bend 93º 100mm 241687 Flue bend (pair) 135º 100mm 241689 NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in accordance with the installation instructions. Burner Gas valve (behind) Vertical flue system Airbox GROUP B | Concentric vertical flue system | 70/110mm diameter Fan protection thermostat Key Fan assembly Item description Specification Vertical roof terminal Condensate trap PCB housing OD dimensions Multifit sales code 70/110mm 242802 Flue extension 1000mm 110mm 241695 Flue bend 93º 110mm 241687 Flue bend (pair) 135º 110mm 241689 *Pitched roof and flat roof flashing available – see page 34 Plume displacement kits GROUP L | Plume displacement kits | 70/110mm diameter Key HOW WE MAKE IT EASY Fits both open vented or sealed heating systems. page 27 Item description Specification Plume displacement kit (inc elbow and clips) Plume displacement kit (extension inc clip) 1000mm OD dimensions Multifit sales code 110mm 5121371 70mm 5121372 page 28 We maintain a number of Bermuda boilers. They’re very reliable and require minimal fuss during the installation process as they fit in easily behind the fireplace. Carl Broadbent Agoura Heating Baxi Bermuda BBU HE Made by Baxi, the inventors of the original back boiler, the Baxi Bermuda BBU HE is the only high efficiency boiler to act as a direct replacement. Fitting a like for like boiler minimises disruption and saves valuable living space. Total peace of mind The Baxi Bermuda BBU HE comes with a 2 year parts and labour warranty*. Accessories The following accessories are compatible with the Baxi Bermuda BBU HE. 2 yr WARRANTY* page 29 ROOM SEALED APPLIANCE NO PUMP OVERRUN REQUIRED SINGLE PIECE FLUE Key features Benefits 15kW modulating heat output Optimum performance at all times Room sealed appliance No air vents required Built-in condensate pump and no pump overrun required Installed with minimal disruption to the customer Gas valve is factory set Quick and simple commissioning Single piece flexible concentric flue No flue inspection access required Like for like replacement No loss of valuable space for householder No need to re-site the boiler or modify pipework No major disruption or redecoration Complies with legislation and building regulations No special paperwork or permission required Megaflo Eco Solar cylinder Megaflo Eco Systemfit cylinder Baxi Solarflo Range of fire fronts *Subject to registration and an annual service. Terms and conditions apply. page 30 Baxi Bermuda BBU HE – nodepth need for airincluding vents. C Boiler = 330mm flue sampling point Opening Baxi Bermuda BBU HE Builders Sales Code 630mm min Controls A Concealed userFireplace controls Opening User adjustable CH temperature LED status/fault diagnosis display Width [A] Height [B] 3 Factory preset 3 Gas Boiler dimensions Gas supply pipe490mm size Natural gas Depth [C] 15mm compression mm 560mm min LPG (butane/propane) 430mm550mm 330mm Nominal inlet supply pressure m /hr Heat output CH non condensing Heat output CH condensing Seasonal efficiency Solid, non combustible SEDBUK (2005) rating hearth to support the boiler, HEARTH 595m m (R O NLY - 575m m ) Fireplace Opening 630m m m in hei gh t insid e b u ild ers op en in g kW max net To accommodate the fire front without the need for additional Builders spacers, there must Opening be a gap of at least 95mm from the surround or finished face to the front of the boiler. 630mm min ent kW max gross If necessary, this gap can be increased by the use of spacer kits. Each spacer increases the effective depth of the opening by up to 50mm. Alternatively, a range of rebated fire surrounds are available. LEVEL kW max 15 kW max 15.7 0.1 Band A NOx class 5 NOx levels mg/kWh 4 core wire Power consumption Watts External fuse rating Amps 3 Internal fuse rating Amps 3.15 31 112 24 hour pump exercise 3 Not required Pump overrun Compartment ventilation required 15.38 %9 3 Electrical cable required Mechanical and hydraulic 17.1 230/50Hz Permanent live required 7 1.63 Heat input central heating B Volts/Hz Electrical supply 3 20 3 SURROUND OR FINISHED Maximum gas rate WALL FACE Clearances 710153301 Electrical 595m m (R O NLY - 575m m ) Technical specifications Technical details HOW width WE MAKE IT EASY A Boiler = 430mm including connections and fittings Room sealed appliance B Boiler height = 550mm including air vent None Flow and return pipe size mm Condensate discharge pipe connection mm 22 male copper 10 Bypass required Yes (pressure operated) Vertical pipe route No inverted pipework permitted CH system inhibitor required 3 Concentric flue system Outside diameter mm Max equivalent length vertical m 100 10 Weights Max installation lift weight kg 27 Gross packaged boiler weight kg 28 Accessories Right hand plumb kit Sales code 720111701 450mm min 400mm min (with spacer) 486mm min (Regalia ONLY) When surveys highlight that space is restricted versus minimum site 490mm requirements, the use of rebated surrounds is recommended. 560mm min C HEARTH LEVEL Solid, non combustible hearth to support the boiler, Fire – all measurements given in mm 490mm 450mm min 400mm min (with spacer) 486mm min (Regalia ONLY) 560mm min C What’s in the box? HEARTH LEVEL Solid, non combustible hearth to support the boiler, Boiler and fire Fascia height Fascia width Dimension ™ Regalia BBU firefront+ 05847A1 720331401 720 600 Dimension ™ Innova BBU firefront* 0584711 720331301 632 542 Dimension ™ Classica brass BBU firefront+ 0584721 720330701 615 512 Dimension Classica pewter BBU firefront+ 0584701 720330801 615 Dimension ™ Dream gold BBU firefront+ 05847C1 720331001 636 Dimension ™ Dream chrome BBU firefront+ 05847D1 720331101 636 Dimension ™ Lyrica BBU firefront+ 0584511 720331601 Model Part number Classica, Lyrica, Nano and Innova spacer kit 5135632 ™ SURROUND OR FINISHED WALL FACE B Fire only Model 630m m m in hei gh t insid e b u ild ers op en in g A Fireplace Opening 595m m (R O NLY - 575m m ) C Boiler depth = 330mm including flue sampling point Fire and accessories technical specifications Builders Opening 630mm min 630m m m in hei gh t insid e b u ild ers op en in g OR FINISHED A SURROUND Boiler width = 430mm WALL FACE including connections and fittings B Boiler height = 550mm including air vent Fascia depth Engine depth Spacer depth 45 144 50 38 144 50 51 144 50 512 51 144 50 518 79 144 50 518 79 144 50 612 510 74 144 50 Height Width Depth Rebate 610 503 50 NA Accessories – all measurements given in mm 450mm min 400mm min (with spacer) 486mm min (Regalia ONLY) Regalia spacer kit 5135633 715 586 50 NA Dream spacer kit 5135634 625 504 50 NA Right hand plumb kit BBU wall fascia^ 720111701 NA NA NA NA 05847H1 750 650 157 NA + This fire is floor standing only. ^ This fire can be wall mounted or floor standing. * For use with the Innova fire. C Bermuda BBU HE page 31 Plumbing and fixing kit Fitting instructions, user instructions, warranty Condensate pipe and elbow page 32 What’s inside the boiler? Flues Baxi Bermuda BBU HE Bermuda flue system Automatic air vent Flue connection The Baxi Bermuda BBU HE is only suitable for use with the following flue kits: Spark generator (located behind PCB) Key Condensate outlet Flow connection Item description Specification OD dimensions Multifit sales code 10m concentric flexible flue Complete with terminal 110mm 710143901 Flue pull cone* Complete with terminal 100mm 720111801 * The flue pull cone must be used for pulling the concentric flexible flue down the chimney. The flue pull cone can then be retained for future installations. Flue sampling point Air sampling point Spark and sensing electrodes (located behind PCB) PCB control box Heat exchanger (located behind PCB) User interface connector Control wiring connector Return connection Drain Fan Condensate pump Gas cock Condensate sump HOW WE MAKE IT EASY Single piece flue, no inspection access required. page 33 page 34 Flue solutions 1. Baxi boilers can be fitted with flue systems as illustrated. 2. The standard flue is suitable only for horizontal termination applications. 3. Maximum permissible equivalent flue lengths for: GROUP G Concentric vertical flue system | 80/125mm diameter for use with Platinum HE A, Duo-tec HE A and Megaflo HE A 4. Any additional “in line” bends in the flue system must be taken into consideration. Their equivalent lengths for Platinum Combi HE A, Duo‑tec Combi HE A, Megaflo system HE A and Solo HE A are: • Platinum Combi HE A, Duo-tec Combi HE A and Megaflo system HE A Horizontal concentric Vertical concentric Horizontal twin pipe Vertical twin pipe Group A 10m 10m 15m 15m Group G 20m 20m Concentric pipes The elbow supplied with the boiler is not included in any equivalent length calculations. For Platinum HE A, Duo-tec HE A, Megaflo HE A Twin flue pipe 4m 4m 75m (parallel pipes) 75m (parallel pipes) Group G 0.5m 1m • Solo HE A Horizontal concentric Vertical concentric Horizontal twin pipe Vertical twin pipe Group A 135° bend 93° bend Group A 135° bend 91.5° bend Key Not illustrated Not illustrated Group G 0.25m 0.50m Not illustrated Twin flue pipe 135° bend (air duct) 135° bend (flue duct) 91.5° bend (air duct) 91.5° bend (flue duct) 1.3m 2.6m 4.8m 9.6m GROUP A Not illustrated Key OD dimensions Multifit sales code 5118576 Flue bend 91.5º 125mm 5118588 Flue bend (pair) 135º 125mm 5118597 125mm 5118610 125mm 5122151 Flat roof flashing 125mm 246144 Roof cover plate 125mm 246143 Pipe support 25/50º Item description Specification OD Multifit dimensions sales code Standard horizontal telescopic flue inc elbow 315mm - 500mm 60/100mm 5118069 Standard horizontal flue inc elbow 60/100mm 5118489 685mm Telescopic internal flue kit 100mm 5119654 Flue extension 1000mm 100mm 5111074 Flue bend 93º 100mm 5111075 Flue bend (pair) 135º 100mm 5111085 Flue bend 135º 100mm 5111076 100mm 5111067 100mm 5111080 60mm 5111068 100mm 720550801 5111074 Flue bend (pair) 135º 100mm 5111085 Not illustrated Flue internal fixing kit / wall liner Pipe support Flue terminal deflector Low profile flue elbow Painted white Flue bend 93º 100mm 5111075 Not illustrated Pipe support Painted white 100mm 5111080 Not illustrated 125mm 5122151 NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in accordance with the installation instructions. Flat roof flashing 125mm 246144 Roof cover plate 125mm 246143 25/50º 93º GROUP B Item description Concentric horizontal flue system | 70/110mm diameter for use with Solo HE A Specification OD dimensions Multifit sales code Vertical roof terminal 70/110mm 242802 Vertical flue adaptor (boiler) 110mm 5106888 Flue extension 1000mm 110mm 241695 Flue extension 500mm 110mm 241694 Flue extension 250m 110mm 241692 Flue bend 93º 110mm 241687 Flue bend (pair) 135º 110mm 241689 110mm 243014BAX 125mm 243015 125mm 243016BAX Pipe support Flat roof flashing page 35 5118584 100mm Pitched roof flashing Not illustrated 125mm 1000mm Concentric vertical flue system | 70/110mm diameter for use with Solo HE A Not illustrated 1000mm Flue extension GROUP B Key Flue extension Not illustrated Pitched roof flashing Not illustrated 5111070 Concentric horizontal flue system | 60/100mm diameter for use with Platinum HE A, Solo HE A, Duo-tec HE A and Megaflo HE A Not illustrated 100mm 5111078 100/125mm GROUP A Concentric horizontal flue system | 60/100mm diameter for use with Platinum HE A, Duo-tec HE A and Megaflo HE A Vertical flue terminal 125mm Flue vertical adaptor Horizontal flue system Vertical flue system Specification OD dimensions Multifit sales code For Solo HE A 6. Instructions for guidance and fitting are included in each kit, where appropriate. Item description Specification Vertical flue terminal Pitched roof flashing 5. The illustrations show examples of permissible flue systems. Key Item description Roof cover plate 25/50º 243131 Key Item description Specification OD Multifit dimensions sales code Standard horizontal flue inc elbow 850mm 110mm 236921 Horizontal flue / wall terminal 850mm 110mm 243013BAX Vertical flue adaptor (boiler) 110mm 5106888 Flue extension 1000mm 110mm 241695 Flue extension 500mm 110mm 241694 Flue extension 250m 110mm 241692 Flue bend 93º 110mm 241687 Flue bend (pair) 135º 110mm 241689 110mm 243014BAX Not illustrated Pipe support Not illustrated Flue terminal deflector 248167 NOTE: The 3º fall back on concentric flues can be reduced to 1.5º providing the flue system is adequately clamped in accordance with the installation instructions. page 36 Flue solutions Horizontal flue system (continued) Twin flue system GROUP G GROUP N Concentric horizontal flue system | 80/125mm diameter for use with Platinum HE A, Duo-tec HE A and Megaflo HE A Key Item description Specification Horizontal flue inc boiler & terminal adaptor Not illustrated OD Multifit dimensions sales code 125mm 5118580 Twin flue system | 80/80mm diameter for use with Platinum HE A, Duo-tec HE A and Megaflo HE A Key Item description Specification OD dimensions Multifit sales code Twin pipe flue horizontal terminal kit 80mm 5120172 Vertical flue terminal 125mm 5111078 80/125mm 5111084 Flue extension 1000mm 125mm 5118584 Twin to concentric adaptor Flue bend 91.5º 125mm 5118588 Twin pipe flue adaptor (boiler) 80/80mm 720089801 Flue bend (pair) 135º 125mm 5118597 Twin pipe extension (pair inc brackets) 1000mm 80mm 5111087 Twin pipe flue bend (pair) 90º 80mm 5111072 Twin pipe flue bend (pair) 135º 80mm 5111086 Twin pipe support (pair) Painted white 80mm 5111081 Pitched roof flashing 25/50º Pipe support Painted white 125mm 5118610 Not illustrated 80/80 - 80/125 125mm 5122151 Not illustrated Flat roof flashing 125mm 246144 Plume displacement kits Not illustrated Roof cover plate 100mm 246143 GROUP K GROUP P OD dimensions Multifit sales code Plume displacement kits | 60/100mm diameter for use with Platinum HE A, Duo-tec HE A, Megaflo HE A Key Item description Specification Plume displacement kit inc elbow and clips 100mm Plume displacement kit extension inc clip 1000mm Key OD dimensions Multifit sales code Item description 70/110mm 242802 850mm 110mm 243013BAX Twin pipe flue extension 250mm 80mm 246135 Twin pipe flue extension 500mm 80mm 246136 Twin pipe flue extension 1000mm 80mm 246137 Horizontal / wall terminal Twin pipe flue adaptor set 60mm 5121368 Plume displacement kit bend 93º 60mm 5121369 Plume displacement kit bend (pair) 135º 60mm 5121370 Plume displacement kits | 70/110mm diameter for use with Solo HE A Specification Plume displacement kit inc elbow and clips OD dimensions Multifit sales code 110mm 5121371 Plume displacement kit extension inc clip 1000mm 70mm 5121372 Plume displacement kit bend 93º 70mm 5121373 Plume displacement kit bend (pair) 135º 70mm 5121374 242757 Twin pipe flue bend (pair) 90º 80mm 5121560 Not illustrated Twin pipe flue bend (pair) 135º 80mm 5121561 Not illustrated Pipe support 110mm 243014BAX Not illustrated Twin pipe support (pair) 80mm 5111081 125mm 243015 Pitched roof flashing Item description Specification Vertical roof terminal 5118638 GROUP L Key Twin flue system | 80/80mm diameter for use with Solo HE A 25/50º Not illustrated Flat roof flashing 243016BAX Not illustrated Flue terminal deflector 248167 Not illustrated Roof cover plate 243131 Baxi Bermuda BBU HE The Baxi Bermuda BBU HE is only suitable for use with the following flue kits: Key Item description Specification OD dimensions Multifit sales code 10m concentric flexible flue Complete with terminal 100mm 710143901 Flue pull cone* Complete with terminal 100mm 720111801 *The flue pull cone must be used for pulling the concentric flexible flue down the chimney. The flue pull cone can then be retained for future installations. page 37 page 38 How we can help Baxi Customer Support Works • Expert technical helpline Sign up to works, Baxi’s online loyalty scheme for installers. Benefits include: • UK based customer contact centre • Free Gas Safe notification – save £2.20 + VAT on every registration • Nationwide network of Gas Safe registered engineers • Priority engineer call out and aftersales support • Free annual service reminder sent to your customers on your behalf • Find an Installer listing on the Baxi website to promote your business Baxi Genuine Parts • Great rewards – business points for every appliance you register • Approved parts for Baxi products Visit works2gether.co.uk to find out more • Guaranteed quality, safety and reliability • Nationwide network of approved stockists • Lifetime support for Baxi products Events Visit Baxi Area Sales Managers at your local merchant for an opportunity to get your hands on the latest Baxi boilers and discuss developments in the heating industry. Training For more information and to join us at a merchant local to you, visit baxievents.co.uk • Practical, hands on training • Free of charge product training • A range of specialist courses • Expert trainers, all accredited, former heating engineers • Training centres across the UK Visit baxi.co.uk/training Literature You can order all the literature you need for you and your customers, including: • Range guides • Product brochures for consumers • Installation instructions • User guides • Instructions for discontinued products Call the Baxi literature hotline on 0844 871 1525 or contact your Baxi Area Sales Manager. All our literature can be downloaded from our website baxi.co.uk page 39 Useful information Technical helpline 0844 871 1525 Opening hours Monday - Friday 8.00am - 6.00pm Weekends and bank holidays 8.30am - 2.00pm We are closed on Christmas Day and New Year’s Day Website baxi.co.uk Email [email protected] 0844 871 1525 Opening hours Address Monday - Friday, 8.00am - 6.00pm Weekends and bank holidays, 8.30am - 2.00pm We are closed on Christmas Day and New Year’s Day. Baxi Please note calls may be monitored or recorded. Brooks House Coventry Road Warwick CV34 4LL baxi.co.uk [email protected] Baxi Brooks House Coventry Road Warwick CV34 4LL MADE IN BRITAIN This brochure is printed on paper sourced from well managed forests and other controlled sources. This brochure is printed using vegetable based inks. Please recycle this brochure when you have finished with it. Baxi policy is one of continual improvement and development. The right to change specification and appearance without prior notice is reserved. The reproduction of colours is as accurate as photographic and printing processes allow. The consumer’s statutory rights are not affected. e&oe HEARange/July14