AirTouch 2 Zone Control System
Transcription
AirTouch 2 Zone Control System
AirTouch 2 Zone Control System User Manual www.polyaire.com.au ©2016 Polyaire Pty Ltd Liability Please read the instructions before installing this Zonemaster Zoning Control System. Polyaire Pty Ltd does not accept any responsibility for loss or damage that may occur as a result of the incorrect installation of this Zonemaster Control System. TABLE OF CONTENTS 1) Features 1 2) Wall Controller Layout (Touch Screen) 2 AirTouch 2 AC Zone Unit Full Control Control System 3) Manual Control 3.1 AC Unit On/Off 3.2 User Manual 3.3 Group On/Off/Turbo 3.4 Adjusting airflow for a group 4) Automated Control 3 3 3 4 5 5 4.1 Set Program 4.2 Select Program for a Group or AC 4.3 AC Timer 5 6 7 5) User Settings 7 5.1 Wi-Fi Setup 8 5.2 Time/Date Setup 11 5.3 Owner’s Name 11 5.4 Turbo Group 5.5 Temperature Display 12 13 5.6 Touch Tone 13 6) Information Sheets 14 7) Troubleshooting Guide for Touch Screen 17 8) AirTouch 2 Apps 18 9) Specifications 21 www.polyaire.com.au ©2016 Polyaire Pty Ltd 1) Features • Userfriendlylargetouchscreeninterface • WirelessremotecontrolusingsmartWiFienableddevices(iPhone,Androids and tablets) • Controlfromanywhereviainternet* • Intuitiveuserinterface • ControlACunit1indifferentlevels(optional,workswithcertainbrandsand models only) AirTouch 2 Zone Control System • ControluptotwoACs User Manual • Controlairflowtoindividualzones2 and groups3 • ColorLCDforclearerdisplay • Personalizedsystemsettingsandlabelling • Wallmountedwithuptotwotouchscreensavailableinasystem • 5-1-1ProgrammableOn/OfftimeprogramsandACTimer • Oneselectable turbo4grouptocool/heataparticularareaquickerforeach ducted system • HalfYear,OneYearandTwoYearservicereminderstocalltechnicianforcleaning andservicingACsystem. • Allzonesautomaticallyresumetheiroriginalon/offstateoncepowerisrestored afterpoweroutage. * Internet access will depend on the home router and may result in some data usage (about 25MB per month) 1. AC unit is the ducted air conditioner which is connected to AirTouch 2 via main module or extension module 2. A zone is the area where air supply is controlled by one motorized damper 3. A group is a few zones grouped together which have the group name and are controlled (turning on and off,oradjustingopeningpercentage)atthesametime.Agroupwillhaveatleastonezoneandnomore than four zones. 4. Turbo functionwillgivetheselectedgroupafull-openingwhileallothergroups’(dampers)opening positions are reduced by 50% of their open percentage value. This will bring a large volume of extra air into the designated area and cool or heat the area quicker. www.polyaire.com.au ©2016 Polyaire Pty Ltd ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 1 2) Wall Controller Layout (Touch Screen) ThehomescreenoftheAirTouch2touchpadnormallydisplaysgroups’status, dampers’openpercentagewithadjustingbuttons,date,time,roomtemperature, WiFi(ifavailable)logo,ACstatus,ACcontrol(detailsdependingontheinstallation) touchtonestatusandAirTouch2logoasshownbelow. Home Screen NOTE: 2 • Thetouch screen will go to sleep mode after 90 seconds of inactivity. In sleep mode, the screen is blank. Touching any area of the screen will activate the system. • Toclean the touch screen, use a dry, soft cloth and very gently wipe the screen. If necessary, dampen the cloth with distilled water or with an equal ratio of distilled water to white vinegar. ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 3) Manual Control 3.1 ACUnitOn/Off AirTouch 2 Zone Control System User Manual IfanACunitisconnectedtoAirTouch2withoutagateway,itcanbeturned on/offonthehomescreenofAirTouch2.TheACnameisgivenintheAC setupsection.ThepowerbuttonshowstheACstatus.Touchingthebutton willswitchtheACunitonoroff. IfACisnotsetup,therewillbenoACnameorpowerbuttononthehome screen. IftwoACsareinstalled,the“>”ontherightsideoftheACnamewillbring upthenextAC. 3.2 AC Unit Full Control WhentherelevantgatewayisconnectedbetweentheACindoorPCBand AirTouch2,ACon/off,operationmode,fanspeedandsetpointcanbe controlledfromtheAirTouch2touchscreen. SupportedbrandsareDaikin,Panasonic,Fujitsu,MitsubishiElectric,Mitsubishi www.polyaire.com.au HeavyIndustries,ToshibaandLG. ©2016 Polyaire Pty Ltd ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 3 ACOn/OffControlisthesameastheOn/OffonlyACcontrol. ACModeControl:Cool,Heat,Dry,FanandAutomodecanbecontrolledfrom AirTouch2bytouchingthemodeboxandselectthemoderequired. SetPointcanbesettodesiredvaluefromAirTouch2screenbytouchingUp andDownbuttonsabove/belowthesetpointbox.Thelowandhighlimitsfor thesettingis10and32respectively. Fanspeed:Itcanhaveuptofivechoices:Quite,Low,Medium,HighandAuto. ThenumberoffanspeedwilldependontheACmodels.AirTouch2can automaticallypickupthefanspeednumberanddisplaythemadaptivelywhen thecorrespondinggatewayisconnected.Touchthefanspeedpulldownbox willbringupavailablefanspeedsandselectthedesiredonebytouchingit. NOTE: If ‘AC Error’ is displayed, it means AC has experienced problems. If the system has full AC control, the error number will be in the message box and can be used to trace the problem. 3.3 GroupOn/Off/Turbo a) Onthehomescreen,touchtheOn/Offbuttontochangethegroupstatus andthedampersofthegroupwillopenorcloseaccordingly. b) Thegroupstatuscanbesetto‘TURBO’activewhenthegroupisspecified asaturbogroup(referto5.4)andthegreyturboindicatorwillturnblueto indicatetheTURBOfunctionisactive. c) Upto6groupbuttonsareshowninonescreen.Touch>or<tobringup previousornextpage. IftwoACsinstalledwithtwoductedsystems,thegroupsareACrelated. IfACunit1’sstatusandcontrolareshownontheleft,thegroupsonthe rightareallconnectedtoACunit1.Touchthe“>”buttonontherightsideof theACunitnamewillbringupACunit2’sstatusandcontrolontheleft,and thegroupsshownontherightareallconnectedtoACunit2. NOTE: A group can have up to a maximum of 4 zones. Your installer should have already set up your zones and groups. 4 ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 3.4 Adjustingairflowforagroup • Thedamperopeningpercentageforeverygroupcanbeadjustedtocontrol theamountofairflowateveryoutletbetween10%and100%ofthe balancedvalue(setupbyInstaller)at10%increments. • Touch>or<buttonsnexttogroupnamestoincreaseordecreasethe percentage opening for the corresponding group. AirTouch 2 Zone Control System • TheairflowwillbeunadjustableiftheTurbofunctionisactiveorSafetyis activated.Pressing>and<willnotchangetheopeningpercentage. 4) Automated Control User Manual Automatedon/offcontrolforeachgroupandtheACunitisanimportantfeature oftheAirTouch2system.Thissystemhasaprogramcapabilitywiththreepossible programsettings,oneforweekdays(MondaytoFriday),oneforSaturdayandone forSundayrespectively. Eachprogramhas4programmableeventsperday:ontime1,offtime1,ontime2 andofftime2.Eachprogrameventcanbeenabled/disabledandtheirtimecanbe adjustedasdesired.Allfoursetsofprogramaredisabledinthefactorydefault. NOTE: The Turbo function cannot be programmed. It is activated manually from the touch screen as needed. Touchthe‘Program’Tabtoenter‘Programming’. 4.1 Set Program Upto4programsandoneACtimercanbesetupforeachductedsystem. a) Touchthebuttonoftheprogram(e.g.Program1)on‘programming’screen to enter the program time screen b) TouchtherelevantareatoselectMonday-Friday,SaturdayorSunday programandtheONorOFFoperationtomodify. c) Usethetimewheeltochoosethetimeforeachoperation. www.polyaire.com.au ©2016 Polyaire Pty Ltd ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 5 4.2 Select Program for a Group or AC Enterthe‘Assignment’screenbytouchingAssignmentonprogramming screen.Assignmentscreenshowsthelistofthecurrentprogramofeachgroup andtheACUnitwhichwillbethelastiteminthelistifACissetup. TouchtheprogramfieldofagrouportheACunittoshowallprogramoptions. TouchingaprogramoptionwillassigntheprogramtothegrouportheAC unit.EachgroupandtheACunitcanbeassignedwithoneprogramfrom program1toprogram4(‘P1’to‘P4’),andthegroupwillnothaveaprogramif ‘No’isselected.IfaprogramhasbeenassignedtoagrouporACunit,the programindicatorwillappearnexttothegrouporACbuttonifanyofthefour eventsintheprogramisenabled. NOTE: Programs cannot be assigned to a group with turbo status. Record programs and groups to ‘Table 5: Programs’ on Page 16 6 ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 4.3 AC Timer ACtimerfunctionisusefulforautomaticallyswitchingtheACunitonoroffat giventimeifACissetupinAirTouch2.YoucanuseOFFTimerandOnTimer incombinationorseparately.EachACcanhaveatimeriftwoACsareinstalled. a) TouchACTimeron‘Program’screentoenter‘ACTimer‘setupscreen. AirTouch 2 Zone Control System User Manual b) Touchtherelevantareatoenableordisabletherelevanttimer,usethetime wheeltosetthetimefortheoperation.TheACtimericonwillbeon thestatusbariftheACtimerisset. NOTE: If AC is not set up, AC timer will not be available. AC timer function isdifferentfromtheprogramfunction,theenabledtimerwillactonceand will not repeat. If you want the action repeated at the same time, you may look at programs. 5) User Settings TouchUsertoenter‘UserSettings’screen InUserSettings,youcansetupowner’sname,dateandtime,WiFiconnection, www.polyaire.com.au Turbogroup,temperaturedisplayandtouchtone. ©2016 Polyaire Pty Ltd ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 7 5.1 WiFi Setup TheinstructionsinthissectiondemonstratehowtoconnectAirTouch2toa homerouter,whichwillenablethecontrol/operationofACunitandzoning vialocalWiFiandinternet.WhenselectingapositionfortheAirTouch2main moduletobeinstalled,pleasemakesureitiswithintheeffectivecoverrangeof thehomeWiFirouterwhichtheAirTouch2willbeconnectedto.Thiswillensure reasonableWiFisignalstrengthandprovideareliableconnectionbetween AirTouch2andthehomerouteraftertheyareconnectedandthemainmodule isinstalled.Itishighlyrecommendedtoundertakethissetupbyplacingthe AirTouch2mainmoduleascloseaspracticaltotherouter,ideallyabout1.5to 2meters,beforeinstallingthemainmodule. a) Touch‘User’andthen‘WiFi’toenterthe‘WiFiSetup’screen.IfAirTouch2is currentlyconnectedtoaWiFinetwork,itsSSIDnamewillbeticked. b) IfthewirelessnetworkSSIDisknown,touchSSIDfieldtodisplay thekeyboardonscreenandtheninputfirstfewcharactersoftheSSID. TouchEntertoconfirmtheSSIDinput. c) TouchScantostartscanningforavailableWiFinetworks/routers.OrTouch Other…tobringupthemanualinput(gotostepe) NOTE: The system will scan and display two WiFi network SSIDs each time,soitwillbemoreefficientifthecorrectSSIDisinputbeforescanning. The connection can be carried out by scanning or manual input. 8 ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual d) Oncompletionofthescan,uptotwofoundrouterswiththeirSSIDsstarting withtheinputcharacterswillbedisplayed.Touchthedesiredrouter’sname andthengotonextstep.Ifthedesiredrouterisnotinthelist,gobacktob) ortouchOther…togotomanualinput. AirTouch 2 Zone Control System User Manual e) TouchthepasswordfieldtoenterthepasswordoftheWiFinetwork. Touch‘Enter’toconfirm.Inmanualinput,afterinputtingcorrectSSIDand password,Securityhastobechosenbeforeconnecting Choosing found WiFi Networks Manual WiFi Network Input f) Touch‘Connect’toconnectthedesiredWiFinetwork.‘Connecting’will appear on the screen. www.polyaire.com.au ©2016 Polyaire Pty Ltd ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 9 g) TheAirTouch2’sscreenwilldisplay‘Connected’iftheconnectionwas successful.IfWi-Ficonnectionfailedgobacktoa) to restart the process. h) TheWi-FilogowillappearonthestatusbarafterconnectingtotheWiFi network.Theconnectionwillstaypermanenttillthesettingchangesonthe homeroutersuchasSSID,password,securitylevels,filtersandothers.The connectionwillautomaticallyresumeafterpoweroffandoncycle. NowyoucanrunAirTouch2applicationsonyoursmartdevicestocontrol ACorzoning. 10 ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 5.2 Time/Date Setup a) TouchDate/Timetabonthe‘User’screentoenterthetime/datesetup screen. b) Hour,Minute,AM/PM,day,monthandyearfieldswillbeshownonthe screen.Touchthefieldwhichneedtobemodified,thenturnthewheelsto changethevalue. AirTouch 2 Zone Control System User Manual 5.3 Owner’s Name Owner’snameisusedbymobileappstodistinguishdifferentAirTouch2ifmore thanonesysteminstalledindifferentlocations.Themaximumlengthofthe name is 16 letters. GotoOwnerNamemenuandtouchtheboxnexttoOwnerNametochange theowner’snamebyusingthekeyboard.TouchShifttoswitchbetweenlower caseanduppercaseandtouchEntertoconfirmthenamechange. www.polyaire.com.au ©2016 Polyaire Pty Ltd ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 11 5.4 Turbo Group Touch‘TurboGroup’tospecifyagroupasaTurboGroup.Turbofunctionwill givetheselectedgroupafull-openingwhileallothergroups’(dampers) openingpositionsarereducedby50%oftheiropenpercentagevalue.Thiswill bringalargevolumeofextraairintothedesignatedareaandcoolorheatthe areaquicker.Typicallythismaybeafamilyroom,diningroomorhometheatre (orincommercialapplicationameeting,lunchorboardroom). Touchthe‘TurboGroup’fieldtodisplaythelistofavailablegroupname. Choosethedesiredgroupnameastheturbogroup.Theturboindicatorwill appearbetweenthegroupnameanditsOn/Offbutton. Iftwoductedsystemsinstalled,twoTurbogroupscanbeset,oneforeach system. NOTE:Tomakethespecifiedgroupstarttoworkinturbomode,thegroup status need to be turn to ‘turbo’ on the home screen (3.2). 12 ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 5.5 Temperature Display Roomtemperaturecanbedisplayedonthetouchscreenornotbytickingor untickingtheitem. IfagatewayisconnectedtoAirTouch2,thetemperaturedisplayedonthetouch screenisfromtheACunit.Inothercases,thetemperaturewillbealways measured at the touch screen. AirTouch 2 Zone Control System User Manual TemperatureCalibrationisforadjustingthevaluereadfromtheAirTouch2 touchpadsensor.UserscanchangethevalueinlinewithACwallcontrolleror other more accurate temperature measurement. 5.6 Touch Tone Thetouchtonefeatureallowstoeitherenableordisablethetonewhenthe screenistouched.Itisdisabledasdefaultandwilldisplayamutelogo onthescreen.GotoTouchTonemenuandtouchtheradiobuttontoswitchthe touchtoneonoroff. www.polyaire.com.au ©2016 Polyaire Pty Ltd ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 13 6) Information Sheets Theseshouldbefilledoutbytheinstaller Table 1: System Configuration Total Groups Bypass Damper Installed Supply Air Sensor Installed Yes/No Yes/No Table 2: Grouping Group Group Name Zones Included Turbo Function 1 2 3 4 5 6 7 8 9 A B C D E F G 14 ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual Table 3: Balance Zone Balance Percentage AirTouch 2 Zone Control System Zone 1 Zone 2 Zone 3 Zone 4 User Manual Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone A Zone B Zone C Zone D Zone E Zone F Zone G Table 4: Installer Details Installer Contact Number Date www.polyaire.com.au ©2016 Polyaire Pty Ltd ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 15 Table 5: Programs PROGRAM 1 On time 1 Off time 1 On time 2 Off time 2 On time 1 Off time 1 On time 2 Off time 2 On time 1 Off time 1 On time 2 Off time 2 On time 1 Off time 1 On time 2 Off time 2 Monday-Friday Saturday Sunday Groups/ACs PROGRAM 2 Monday-Friday Saturday Sunday Groups/ACs PROGRAM 3 Monday-Friday Saturday Sunday Groups/ACs PROGRAM 4 Monday-Friday Saturday Sunday Groups/ACs 16 ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 7) Troubleshooting Guide for Touch Screen PROBLEM Dampers have no response when turned on or off SUGGESTED ACTION • Checkifthe‘Safety’errorisdisplayed.Highlimit(Heating)orLow limit(Cooling)mayhavereached.Checktheair-conditionertoseeifit isoperatingnormally.AirTouch2systemwillresumetooperational afterthesupplyairtemperatureiswithinsafetyrange. AirTouch 2 Zone Control System • *CheckifSupplyairsensorispluggedinthemainboardandHighLimit &LowLimitisenabled.Ifthesensorisnotpluggedin,plugthesensor andthesystemwillbeoperationalafteraminute.Ifthesensorisnot required,disableHighlimitandLowlimitfromtouchpadandsystem willreturntooperationalinaminute. • *CheckifLEDsonthemainmodulelightupforrelevantzoneswhen thezonedampersarebeingturnedOn/Off.IfGreen/RedLEDsarenot activatedfortherespectivezone,themainmodulemaybefaulty, replace it. User Manual •*Check if the cable from touchpad to the main control module is faulty. Ifitisafaultycable,thenreplacethecable. Some zones cannot be turned off • Checkif‘Spill’isdisplayedontheLCDscreen. • Checkif‘Spill’statusisdisplayedfortheGroupstatus.Openingother zoneswillrectifytheerror • *Ifallzonesareturnedonwithlowopeningpercentagebutthetotal openingpercentagedoesn’tmeettherequiredspillpercentage,then theSPILLwarningmessagewillbedisplayed.Increasingtheopening percentageofafewzoneswillresolvetheissue. • *Checkspillset-point. No display on the LCD • *Checkifthecableispluggedinproperly.Unplugthecableand reconnect it. LCD Display Corrupted • ResetLCDbyholdingRESETbuttonatthebottomoftheTouchpad for 2s. Some zones are not operational • *Checkifthereispowertotheunit. • *Iferrorisstillnotresolved,resettouchpadbyunpluggingthecable frombehindandthenreconnectitafterabout15seconds.Ifthe corrupteddisplayremains,poweroff/onthemainboard.Otherwise, replace the touchpad. • *CheckGroupingandfindoutiftherightzoneshavebeenassignedto therightgroupsandhavebeenturnedON/OFFinZoningsection. • *Checkifthetotalgroupnumberandzonenumberarecorrect. • ‘AC ERROR’ is displayed on touchpad *CheckiftheLEDsonthemainmodulelightupfortherelevantzones whenthezonedampersareturnedOn/Off.Ifthereisnoresponse, theremightbeafaultycableandthecablewouldhavetobereplaced. Ifthezoneisstillnon-functionalthentheremightbeafaultydamper motor. •*ThiserrorisdisplayedduetoafaultwiththeACunit.TheACON/OFF functionwillbedisabledwhenthiserrorisdisplayed.Pleasecheckthe ACunit/ACtouchpadtofixtheproblem. www.polyaire.com.au *: Thesechecksshouldbecarriedoutbyqualifiedpersonnel. If you have any doubt regarding the above please contact your installer. ©2016 Polyaire Pty Ltd ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 17 8) AirTouch 2 Apps 8.1 Downloading and Installing the AirTouch 2 Apps AirTouch2applicationscanbedownloadedfromthefollowinglocations. Theapplicationsareavailablefreeofcharge. For Android Phones: GotoMarket/GooglePlaystorefromyourAndroid phoneandsearchforAirTouch2applicationdevelopedbyPolyaire.After downloadingtheapplication,openthefileandfollowthepromptstoinstallthe applicationonyourphone.TheAirTouch2AppsupportsAndroid3.0.andnewer For iPhones:GototheAppstoreandsearchforAirTouch2application developedbyPolyaire.TapontheAirTouch2AppandpressInstall.Enter youriTunespasswordandtheAirTouch2appwillbeautomaticallydownloaded andinstalledonyouriPhone.TheAirTouch2AppsupportsiOS8.0.andnewer. 8.2 Using AirTouch 2 Apps. 1. OnthetouchscreenwhenyougettotheInstaller’ssettingpage 2. OnthecoverofthemainmoduleofAirTouch2 18 WhenmobilesandAirTouch2areallconnectedtothesameWiFinetwork,the AirTouch2appwillrunstraightawayandthecontrolinterfacewillcomeup. Otherwise,you’llneedinternetconnection(viaotherWiFinetworksor3G/4G network)andpasswordtoruntheapp.Ifit’sthefirsttimetoruntheappvia internetandtheapphasnotsuccessfullyrunonthesameWiFinetworkasthe AirTouch2before,youwillneedthedeviceIDandpasswordtoruntheapp successfully.ThedeviceIDcanbefound: ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual TheFiguresbelowshowsthehomepageoftheapp. Theoperationsaresimpleandstraightforward. AirTouch 2 Zone Control System User Manual AC On/Off Control AC Full Control Zone Control for Two Ducted Systems NOTE: • Turbozonecanbeactivatedbytappingtherespectivechosenzoneuntil activeTurboiconappearsonthatparticularzone. • TemperaturedisplaycanbeturnedofffromSystem • Tochangenamesofgroup/zone,gotoSystem,thenNamingpageandfollow the prompts. • PasswordforInternetaccesscanbechangedinSystem • Toprogramgroups/zonesandACunit,orsettimerforACunit,gotoProgram andfollowtheprompts.ThetimesetintheprogramsandTimerwillbetimeof theAirTouch2system. www.polyaire.com.au ©2016 Polyaire Pty Ltd ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 19 8.3 Troubleshooting Guide for AirTouch 2 App NO PROBLEM SUGGESTED ACTION a) ClosetheAirTouch2appandrestartagain. 1 2 3 b) CheckifthephoneWiFiisturnedONandisconnectedtothe samerouterwhichtheAirTouch2isconnected. AirTouch 2 app displays “No networks detected restart” c) Checkiftherewasapowerfailure.Ifso,waitforAirTouch2 tore-establishconnectionwiththehomerouter(3minutes fromPowerON).NowcheckiftheWiFiicon( )isbackon thescreenandthentryre-openingtheapp.IfWiFiicondoes not appear refer to point 2. a) Afterapowerfailure,AirTouch2willre-connecttohome routerandWiFiicon( )willbebackonin3minutesfrom PowerON. WiFi symbol ( ) disappeared from the touchpad. b) TurnthewirelessrouterOFFandturnitbackON.Waitfor3 minutesfortheAirTouch2systemtoinitialise. c) IfWiFiicon( )doesnotappear,followWiFisetupprocess tore-establishconnectionbetweenyourhomerouterand AirTouch2. AirTouch 2 app does not respond even if the app is in operation. WiFiconnectionmayhavedroppedduetonoactionfromthe mobile for a period of time. a) ClosetheAirTouch2appandrestartit. ‘Send message error’ is displayed. b) OrTurnthephoneoffandrestartit. 4 ‘SPILL’ warning message is displayed Thismeansthatthespillfunctionhasbeenactivatedasasafety measurebecausetoomanyzoneshavebeenturnedOFF. TurningONmorezoneswillresolvetheissue. 5 ‘SAFETY’ warning message is displayed Thismessagemeansthesafetyprotectionhasbeenactivated duetoveryhighorlowtemperaturesreachedatthesupplyair end.PleasechecktheACsystemtofixtheproblem. 6 ‘HALF/ONE/TWO YEAR SERVICE DUE...’ message is displayed Thisisthemessageset-upbyyourinstallertoalertyoutoclean yourfiltersorserviceyourair-conditionerevery6months, 1yearand2yearsrespectively.Thismessagecanberemoved by touching the message area on the touchpad. 7 ‘AC ERROR’, warning message is displayed ThiserroristriggeredduetoafaultwiththeACunitconnected to.Pleasechecktheair-conditioningsystemtoresolvethe issue. *: Thesechecksshouldbecarriedoutbyqualifiedpersonnel. If you have any doubt regarding the above please contact your installer. 20 ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 9) Specifications Electrical Requirements Powersupply: 24VAC±10% Linefrequency: 50Hz Touchpad: AirTouch 2 0.5VA MainControlModule: 5VA System Zone Control Components Power Consumption User Manual Environmental Requirements Operatingtemperature: 0°Cto60°C Altitude: 0to2000meters Operatingrelativehumidity: Avoidstaticelectricityhazards 10%to80% Avoidelectromagneticradiationsources Avoiddustcontamination Avoidhighlycorrosiveenvironments Outputvoltage: 24VAC,50Hz Current: 200mA(1dampermotor) InputVoltage: 240VAC,50Hz OutputVoltage: 24VAC,50Hz Wattage: 40W Supply Air Sensor: NTCtype,10kΩat25°C Zone Output Transformer Battery: 3.0V,ML2032 RechargeableforMainModule Fuse: Dimension5x20mm, Fast-Acting2A,250V www.polyaire.com.au ©2016 Polyaire Pty Ltd ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual 21 POLYAIRE PTY LTD 11-13WHITEROAD GEPPSCROSS SOUTHAUSTRALIA,5094 TEL:(08)83498466 FAX:(08)83498446 www.polyaire.com.au ZMAT2_USR_V2.0