AirTouch 2 Zone Control System

Transcription

AirTouch 2 Zone Control System
AirTouch 2
Zone Control System
User Manual
www.polyaire.com.au
©2016 Polyaire Pty Ltd
Liability
Please read the instructions before installing this Zonemaster Zoning Control System.
Polyaire Pty Ltd does not accept any responsibility for loss or damage that may occur as a result of the incorrect
installation of this Zonemaster Control System.
TABLE OF CONTENTS
1) Features
1
2) Wall Controller Layout (Touch Screen)
2
AirTouch 2
AC Zone
Unit Full Control
Control System
3) Manual Control
3.1 AC Unit On/Off
3.2
User Manual
3.3 Group On/Off/Turbo
3.4 Adjusting airflow for a group
4) Automated Control
3
3
3
4
5
5
4.1 Set Program
4.2 Select Program for a Group or AC
4.3 AC Timer
5
6
7
5) User Settings
7
5.1 Wi-Fi Setup
8
5.2 Time/Date Setup
11
5.3 Owner’s Name
11
5.4 Turbo Group
5.5 Temperature Display
12
13
5.6 Touch Tone
13
6) Information Sheets
14
7) Troubleshooting Guide for Touch Screen
17
8) AirTouch 2 Apps
18
9) Specifications
21
www.polyaire.com.au
©2016 Polyaire Pty Ltd
1) Features
• Userfriendlylargetouchscreeninterface
• WirelessremotecontrolusingsmartWiFienableddevices(iPhone,Androids
and tablets)
• Controlfromanywhereviainternet*
• Intuitiveuserinterface
• ControlACunit1indifferentlevels(optional,workswithcertainbrandsand
models only)
AirTouch 2
Zone Control System
• ControluptotwoACs
User Manual
• Controlairflowtoindividualzones2 and groups3
• ColorLCDforclearerdisplay
• Personalizedsystemsettingsandlabelling
• Wallmountedwithuptotwotouchscreensavailableinasystem
• 5-1-1ProgrammableOn/OfftimeprogramsandACTimer
• Oneselectable turbo4grouptocool/heataparticularareaquickerforeach
ducted system
• HalfYear,OneYearandTwoYearservicereminderstocalltechnicianforcleaning
andservicingACsystem.
• Allzonesautomaticallyresumetheiroriginalon/offstateoncepowerisrestored afterpoweroutage.
* Internet access will depend on the home router and may result in some data
usage (about 25MB per month)
1. AC unit is the ducted air conditioner which is connected to AirTouch 2 via main module or extension
module
2. A zone is the area where air supply is controlled by one motorized damper
3. A group is a few zones grouped together which have the group name and are controlled (turning on and
off,oradjustingopeningpercentage)atthesametime.Agroupwillhaveatleastonezoneandnomore
than four zones.
4. Turbo functionwillgivetheselectedgroupafull-openingwhileallothergroups’(dampers)opening
positions are reduced by 50% of their open percentage value. This will bring a large volume of extra air
into the designated area and cool or heat the area quicker.
www.polyaire.com.au
©2016
Polyaire
Pty
Ltd
ZONEMASTER AIRTOUCH 2 ZONE CONTROL
SYSTEM
- User
Manual
1
2) Wall Controller Layout (Touch Screen)
ThehomescreenoftheAirTouch2touchpadnormallydisplaysgroups’status,
dampers’openpercentagewithadjustingbuttons,date,time,roomtemperature,
WiFi(ifavailable)logo,ACstatus,ACcontrol(detailsdependingontheinstallation)
touchtonestatusandAirTouch2logoasshownbelow.
Home Screen
NOTE:
2
•
Thetouch screen will go to sleep mode after 90 seconds of inactivity.
In sleep mode, the screen is blank. Touching any area of the screen will
activate the system.
•
Toclean the touch screen, use a dry, soft cloth and very gently wipe the
screen. If necessary, dampen the cloth with distilled water or with an
equal ratio of distilled water to white vinegar.
ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual
3) Manual Control
3.1 ACUnitOn/Off
AirTouch 2
Zone Control System
User Manual
IfanACunitisconnectedtoAirTouch2withoutagateway,itcanbeturned
on/offonthehomescreenofAirTouch2.TheACnameisgivenintheAC
setupsection.ThepowerbuttonshowstheACstatus.Touchingthebutton
willswitchtheACunitonoroff.
IfACisnotsetup,therewillbenoACnameorpowerbuttononthehome
screen.
IftwoACsareinstalled,the“>”ontherightsideoftheACnamewillbring
upthenextAC.
3.2 AC Unit Full Control
WhentherelevantgatewayisconnectedbetweentheACindoorPCBand
AirTouch2,ACon/off,operationmode,fanspeedandsetpointcanbe
controlledfromtheAirTouch2touchscreen.
SupportedbrandsareDaikin,Panasonic,Fujitsu,MitsubishiElectric,Mitsubishi
www.polyaire.com.au
HeavyIndustries,ToshibaandLG.
©2016
Polyaire
Pty
Ltd
ZONEMASTER AIRTOUCH 2 ZONE CONTROL
SYSTEM
- User
Manual
3
ACOn/OffControlisthesameastheOn/OffonlyACcontrol.
ACModeControl:Cool,Heat,Dry,FanandAutomodecanbecontrolledfrom
AirTouch2bytouchingthemodeboxandselectthemoderequired.
SetPointcanbesettodesiredvaluefromAirTouch2screenbytouchingUp
andDownbuttonsabove/belowthesetpointbox.Thelowandhighlimitsfor
thesettingis10and32respectively.
Fanspeed:Itcanhaveuptofivechoices:Quite,Low,Medium,HighandAuto.
ThenumberoffanspeedwilldependontheACmodels.AirTouch2can
automaticallypickupthefanspeednumberanddisplaythemadaptivelywhen
thecorrespondinggatewayisconnected.Touchthefanspeedpulldownbox
willbringupavailablefanspeedsandselectthedesiredonebytouchingit.
NOTE: If ‘AC Error’ is displayed, it means AC has experienced problems.
If the system has full AC control, the error number will be in the message
box and can be used to trace the problem.
3.3 GroupOn/Off/Turbo
a) Onthehomescreen,touchtheOn/Offbuttontochangethegroupstatus
andthedampersofthegroupwillopenorcloseaccordingly.
b) Thegroupstatuscanbesetto‘TURBO’activewhenthegroupisspecified
asaturbogroup(referto5.4)andthegreyturboindicatorwillturnblueto
indicatetheTURBOfunctionisactive.
c) Upto6groupbuttonsareshowninonescreen.Touch>or<tobringup previousornextpage.
IftwoACsinstalledwithtwoductedsystems,thegroupsareACrelated.
IfACunit1’sstatusandcontrolareshownontheleft,thegroupsonthe
rightareallconnectedtoACunit1.Touchthe“>”buttonontherightsideof
theACunitnamewillbringupACunit2’sstatusandcontrolontheleft,and
thegroupsshownontherightareallconnectedtoACunit2.
NOTE: A group can have up to a maximum of 4 zones. Your installer should
have already set up your zones and groups.
4
ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual
3.4 Adjustingairflowforagroup
• Thedamperopeningpercentageforeverygroupcanbeadjustedtocontrol
theamountofairflowateveryoutletbetween10%and100%ofthe
balancedvalue(setupbyInstaller)at10%increments.
• Touch>or<buttonsnexttogroupnamestoincreaseordecreasethe
percentage opening for the corresponding group.
AirTouch 2
Zone Control System
• TheairflowwillbeunadjustableiftheTurbofunctionisactiveorSafetyis
activated.Pressing>and<willnotchangetheopeningpercentage.
4) Automated Control
User Manual
Automatedon/offcontrolforeachgroupandtheACunitisanimportantfeature
oftheAirTouch2system.Thissystemhasaprogramcapabilitywiththreepossible
programsettings,oneforweekdays(MondaytoFriday),oneforSaturdayandone
forSundayrespectively.
Eachprogramhas4programmableeventsperday:ontime1,offtime1,ontime2
andofftime2.Eachprogrameventcanbeenabled/disabledandtheirtimecanbe
adjustedasdesired.Allfoursetsofprogramaredisabledinthefactorydefault.
NOTE: The Turbo function cannot be programmed. It is activated manually
from the touch screen as needed.
Touchthe‘Program’Tabtoenter‘Programming’.
4.1 Set Program
Upto4programsandoneACtimercanbesetupforeachductedsystem.
a) Touchthebuttonoftheprogram(e.g.Program1)on‘programming’screen to enter the program time screen
b) TouchtherelevantareatoselectMonday-Friday,SaturdayorSunday
programandtheONorOFFoperationtomodify.
c) Usethetimewheeltochoosethetimeforeachoperation.
www.polyaire.com.au
©2016
Polyaire
Pty
Ltd
ZONEMASTER AIRTOUCH 2 ZONE CONTROL
SYSTEM
- User
Manual
5
4.2 Select Program for a Group or AC
Enterthe‘Assignment’screenbytouchingAssignmentonprogramming
screen.Assignmentscreenshowsthelistofthecurrentprogramofeachgroup
andtheACUnitwhichwillbethelastiteminthelistifACissetup.
TouchtheprogramfieldofagrouportheACunittoshowallprogramoptions.
TouchingaprogramoptionwillassigntheprogramtothegrouportheAC
unit.EachgroupandtheACunitcanbeassignedwithoneprogramfrom
program1toprogram4(‘P1’to‘P4’),andthegroupwillnothaveaprogramif
‘No’isselected.IfaprogramhasbeenassignedtoagrouporACunit,the
programindicatorwillappearnexttothegrouporACbuttonifanyofthefour
eventsintheprogramisenabled.
NOTE: Programs cannot be assigned to a group with turbo status.
Record programs and groups to ‘Table 5: Programs’ on Page 16
6
ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual
4.3 AC Timer
ACtimerfunctionisusefulforautomaticallyswitchingtheACunitonoroffat giventimeifACissetupinAirTouch2.YoucanuseOFFTimerandOnTimer
incombinationorseparately.EachACcanhaveatimeriftwoACsareinstalled.
a) TouchACTimeron‘Program’screentoenter‘ACTimer‘setupscreen.
AirTouch 2
Zone Control System
User Manual
b) Touchtherelevantareatoenableordisabletherelevanttimer,usethetime
wheeltosetthetimefortheoperation.TheACtimericonwillbeon thestatusbariftheACtimerisset.
NOTE: If AC is not set up, AC timer will not be available. AC timer function
isdifferentfromtheprogramfunction,theenabledtimerwillactonceand
will not repeat. If you want the action repeated at the same time, you may
look at programs.
5) User Settings
TouchUsertoenter‘UserSettings’screen
InUserSettings,youcansetupowner’sname,dateandtime,WiFiconnection,
www.polyaire.com.au
Turbogroup,temperaturedisplayandtouchtone.
©2016
Polyaire
Pty
Ltd
ZONEMASTER AIRTOUCH 2 ZONE CONTROL
SYSTEM
- User
Manual
7
5.1 WiFi Setup
TheinstructionsinthissectiondemonstratehowtoconnectAirTouch2toa homerouter,whichwillenablethecontrol/operationofACunitandzoning
vialocalWiFiandinternet.WhenselectingapositionfortheAirTouch2main
moduletobeinstalled,pleasemakesureitiswithintheeffectivecoverrangeof
thehomeWiFirouterwhichtheAirTouch2willbeconnectedto.Thiswillensure
reasonableWiFisignalstrengthandprovideareliableconnectionbetween
AirTouch2andthehomerouteraftertheyareconnectedandthemainmodule
isinstalled.Itishighlyrecommendedtoundertakethissetupbyplacingthe
AirTouch2mainmoduleascloseaspracticaltotherouter,ideallyabout1.5to
2meters,beforeinstallingthemainmodule.
a) Touch‘User’andthen‘WiFi’toenterthe‘WiFiSetup’screen.IfAirTouch2is
currentlyconnectedtoaWiFinetwork,itsSSIDnamewillbeticked.
b) IfthewirelessnetworkSSIDisknown,touchSSIDfieldtodisplay
thekeyboardonscreenandtheninputfirstfewcharactersoftheSSID.
TouchEntertoconfirmtheSSIDinput.
c) TouchScantostartscanningforavailableWiFinetworks/routers.OrTouch
Other…tobringupthemanualinput(gotostepe)
NOTE: The system will scan and display two WiFi network SSIDs each
time,soitwillbemoreefficientifthecorrectSSIDisinputbeforescanning.
The connection can be carried out by scanning or manual input.
8
ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual
d)
Oncompletionofthescan,uptotwofoundrouterswiththeirSSIDsstarting
withtheinputcharacterswillbedisplayed.Touchthedesiredrouter’sname
andthengotonextstep.Ifthedesiredrouterisnotinthelist,gobacktob)
ortouchOther…togotomanualinput.
AirTouch 2
Zone Control System
User Manual
e) TouchthepasswordfieldtoenterthepasswordoftheWiFinetwork.
Touch‘Enter’toconfirm.Inmanualinput,afterinputtingcorrectSSIDand password,Securityhastobechosenbeforeconnecting
Choosing found WiFi Networks
Manual WiFi Network Input
f) Touch‘Connect’toconnectthedesiredWiFinetwork.‘Connecting’will
appear on the screen.
www.polyaire.com.au
©2016
Polyaire
Pty
Ltd
ZONEMASTER AIRTOUCH 2 ZONE CONTROL
SYSTEM
- User
Manual
9
g) TheAirTouch2’sscreenwilldisplay‘Connected’iftheconnectionwas
successful.IfWi-Ficonnectionfailedgobacktoa) to restart the process.
h)
TheWi-FilogowillappearonthestatusbarafterconnectingtotheWiFi
network.Theconnectionwillstaypermanenttillthesettingchangesonthe
homeroutersuchasSSID,password,securitylevels,filtersandothers.The
connectionwillautomaticallyresumeafterpoweroffandoncycle.
NowyoucanrunAirTouch2applicationsonyoursmartdevicestocontrol
ACorzoning.
10
ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual
5.2 Time/Date Setup
a) TouchDate/Timetabonthe‘User’screentoenterthetime/datesetup
screen.
b) Hour,Minute,AM/PM,day,monthandyearfieldswillbeshownonthe
screen.Touchthefieldwhichneedtobemodified,thenturnthewheelsto
changethevalue.
AirTouch 2
Zone Control System
User Manual
5.3 Owner’s Name
Owner’snameisusedbymobileappstodistinguishdifferentAirTouch2ifmore
thanonesysteminstalledindifferentlocations.Themaximumlengthofthe
name is 16 letters.
GotoOwnerNamemenuandtouchtheboxnexttoOwnerNametochange
theowner’snamebyusingthekeyboard.TouchShifttoswitchbetweenlower
caseanduppercaseandtouchEntertoconfirmthenamechange.
www.polyaire.com.au
©2016
Polyaire
Pty
Ltd
ZONEMASTER AIRTOUCH 2 ZONE CONTROL
SYSTEM
- User
Manual
11
5.4 Turbo Group
Touch‘TurboGroup’tospecifyagroupasaTurboGroup.Turbofunctionwill
givetheselectedgroupafull-openingwhileallothergroups’(dampers)
openingpositionsarereducedby50%oftheiropenpercentagevalue.Thiswill
bringalargevolumeofextraairintothedesignatedareaandcoolorheatthe
areaquicker.Typicallythismaybeafamilyroom,diningroomorhometheatre
(orincommercialapplicationameeting,lunchorboardroom).
Touchthe‘TurboGroup’fieldtodisplaythelistofavailablegroupname.
Choosethedesiredgroupnameastheturbogroup.Theturboindicatorwill
appearbetweenthegroupnameanditsOn/Offbutton.
Iftwoductedsystemsinstalled,twoTurbogroupscanbeset,oneforeach
system.
NOTE:Tomakethespecifiedgroupstarttoworkinturbomode,thegroup
status need to be turn to ‘turbo’ on the home screen (3.2).
12
ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual
5.5 Temperature Display
Roomtemperaturecanbedisplayedonthetouchscreenornotbytickingor
untickingtheitem.
IfagatewayisconnectedtoAirTouch2,thetemperaturedisplayedonthetouch
screenisfromtheACunit.Inothercases,thetemperaturewillbealways
measured at the touch screen.
AirTouch 2
Zone Control System
User Manual
TemperatureCalibrationisforadjustingthevaluereadfromtheAirTouch2
touchpadsensor.UserscanchangethevalueinlinewithACwallcontrolleror
other more accurate temperature measurement.
5.6 Touch Tone
Thetouchtonefeatureallowstoeitherenableordisablethetonewhenthe
screenistouched.Itisdisabledasdefaultandwilldisplayamutelogo
onthescreen.GotoTouchTonemenuandtouchtheradiobuttontoswitchthe
touchtoneonoroff.
www.polyaire.com.au
©2016
Polyaire
Pty
Ltd
ZONEMASTER AIRTOUCH 2 ZONE CONTROL
SYSTEM
- User
Manual
13
6) Information Sheets
Theseshouldbefilledoutbytheinstaller
Table 1: System Configuration
Total Groups
Bypass Damper
Installed
Supply Air Sensor
Installed
Yes/No
Yes/No
Table 2: Grouping
Group
Group Name
Zones Included
Turbo Function
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
G
14
ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual
Table 3: Balance
Zone
Balance Percentage
AirTouch 2
Zone Control System
Zone 1
Zone 2
Zone 3
Zone 4
User Manual
Zone 5
Zone 6
Zone 7
Zone 8
Zone 9
Zone A
Zone B
Zone C
Zone D
Zone E
Zone F
Zone G
Table 4: Installer Details
Installer
Contact Number
Date
www.polyaire.com.au
©2016
Polyaire
Pty
Ltd
ZONEMASTER AIRTOUCH 2 ZONE CONTROL
SYSTEM
- User
Manual
15
Table 5: Programs
PROGRAM 1
On time 1
Off time 1
On time 2
Off time 2
On time 1
Off time 1
On time 2
Off time 2
On time 1
Off time 1
On time 2
Off time 2
On time 1
Off time 1
On time 2
Off time 2
Monday-Friday
Saturday
Sunday
Groups/ACs
PROGRAM 2
Monday-Friday
Saturday
Sunday
Groups/ACs
PROGRAM 3
Monday-Friday
Saturday
Sunday
Groups/ACs
PROGRAM 4
Monday-Friday
Saturday
Sunday
Groups/ACs
16
ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual
7) Troubleshooting Guide for Touch Screen
PROBLEM
Dampers have no
response when
turned on or off
SUGGESTED ACTION
•
Checkifthe‘Safety’errorisdisplayed.Highlimit(Heating)orLow
limit(Cooling)mayhavereached.Checktheair-conditionertoseeifit
isoperatingnormally.AirTouch2systemwillresumetooperational
afterthesupplyairtemperatureiswithinsafetyrange.
AirTouch 2
Zone Control System
•
*CheckifSupplyairsensorispluggedinthemainboardandHighLimit
&LowLimitisenabled.Ifthesensorisnotpluggedin,plugthesensor
andthesystemwillbeoperationalafteraminute.Ifthesensorisnot
required,disableHighlimitandLowlimitfromtouchpadandsystem
willreturntooperationalinaminute.
• *CheckifLEDsonthemainmodulelightupforrelevantzoneswhen
thezonedampersarebeingturnedOn/Off.IfGreen/RedLEDsarenot
activatedfortherespectivezone,themainmodulemaybefaulty,
replace it.
User Manual
•*Check if the cable from touchpad to the main control module is faulty.
Ifitisafaultycable,thenreplacethecable.
Some zones
cannot
be turned off
• Checkif‘Spill’isdisplayedontheLCDscreen.
• Checkif‘Spill’statusisdisplayedfortheGroupstatus.Openingother
zoneswillrectifytheerror
•
*Ifallzonesareturnedonwithlowopeningpercentagebutthetotal
openingpercentagedoesn’tmeettherequiredspillpercentage,then
theSPILLwarningmessagewillbedisplayed.Increasingtheopening
percentageofafewzoneswillresolvetheissue.
• *Checkspillset-point.
No display on
the LCD
• *Checkifthecableispluggedinproperly.Unplugthecableand
reconnect it.
LCD Display
Corrupted
• ResetLCDbyholdingRESETbuttonatthebottomoftheTouchpad
for 2s.
Some zones are
not operational
• *Checkifthereispowertotheunit.
• *Iferrorisstillnotresolved,resettouchpadbyunpluggingthecable
frombehindandthenreconnectitafterabout15seconds.Ifthe
corrupteddisplayremains,poweroff/onthemainboard.Otherwise,
replace the touchpad.
• *CheckGroupingandfindoutiftherightzoneshavebeenassignedto
therightgroupsandhavebeenturnedON/OFFinZoningsection.
• *Checkifthetotalgroupnumberandzonenumberarecorrect.
•
‘AC ERROR’ is
displayed on
touchpad
*CheckiftheLEDsonthemainmodulelightupfortherelevantzones
whenthezonedampersareturnedOn/Off.Ifthereisnoresponse,
theremightbeafaultycableandthecablewouldhavetobereplaced.
Ifthezoneisstillnon-functionalthentheremightbeafaultydamper
motor.
•*ThiserrorisdisplayedduetoafaultwiththeACunit.TheACON/OFF
functionwillbedisabledwhenthiserrorisdisplayed.Pleasecheckthe
ACunit/ACtouchpadtofixtheproblem.
www.polyaire.com.au
*: Thesechecksshouldbecarriedoutbyqualifiedpersonnel.
If you have any doubt regarding the above please contact your installer.
©2016
Polyaire
Pty
Ltd
ZONEMASTER AIRTOUCH 2 ZONE CONTROL
SYSTEM
- User
Manual
17
8) AirTouch 2 Apps
8.1 Downloading and Installing the AirTouch 2 Apps
AirTouch2applicationscanbedownloadedfromthefollowinglocations.
Theapplicationsareavailablefreeofcharge.
For Android Phones: GotoMarket/GooglePlaystorefromyourAndroid
phoneandsearchforAirTouch2applicationdevelopedbyPolyaire.After
downloadingtheapplication,openthefileandfollowthepromptstoinstallthe
applicationonyourphone.TheAirTouch2AppsupportsAndroid3.0.andnewer
For iPhones:GototheAppstoreandsearchforAirTouch2application
developedbyPolyaire.TapontheAirTouch2AppandpressInstall.Enter
youriTunespasswordandtheAirTouch2appwillbeautomaticallydownloaded
andinstalledonyouriPhone.TheAirTouch2AppsupportsiOS8.0.andnewer.
8.2 Using AirTouch 2 Apps.
1. OnthetouchscreenwhenyougettotheInstaller’ssettingpage
2. OnthecoverofthemainmoduleofAirTouch2
18
WhenmobilesandAirTouch2areallconnectedtothesameWiFinetwork,the
AirTouch2appwillrunstraightawayandthecontrolinterfacewillcomeup.
Otherwise,you’llneedinternetconnection(viaotherWiFinetworksor3G/4G
network)andpasswordtoruntheapp.Ifit’sthefirsttimetoruntheappvia
internetandtheapphasnotsuccessfullyrunonthesameWiFinetworkasthe
AirTouch2before,youwillneedthedeviceIDandpasswordtoruntheapp
successfully.ThedeviceIDcanbefound:
ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual
TheFiguresbelowshowsthehomepageoftheapp.
Theoperationsaresimpleandstraightforward.
AirTouch 2
Zone Control System
User Manual
AC On/Off Control
AC Full Control
Zone Control for Two
Ducted Systems
NOTE:
• Turbozonecanbeactivatedbytappingtherespectivechosenzoneuntil
activeTurboiconappearsonthatparticularzone.
• TemperaturedisplaycanbeturnedofffromSystem
• Tochangenamesofgroup/zone,gotoSystem,thenNamingpageandfollow
the prompts.
• PasswordforInternetaccesscanbechangedinSystem
• Toprogramgroups/zonesandACunit,orsettimerforACunit,gotoProgram
andfollowtheprompts.ThetimesetintheprogramsandTimerwillbetimeof
theAirTouch2system.
www.polyaire.com.au
©2016
Polyaire
Pty
Ltd
ZONEMASTER AIRTOUCH 2 ZONE CONTROL
SYSTEM
- User
Manual
19
8.3 Troubleshooting Guide for AirTouch 2 App
NO
PROBLEM
SUGGESTED ACTION
a) ClosetheAirTouch2appandrestartagain.
1
2
3
b) CheckifthephoneWiFiisturnedONandisconnectedtothe
samerouterwhichtheAirTouch2isconnected.
AirTouch 2 app
displays “No
networks detected
restart”
c)
Checkiftherewasapowerfailure.Ifso,waitforAirTouch2
tore-establishconnectionwiththehomerouter(3minutes
fromPowerON).NowcheckiftheWiFiicon( )isbackon
thescreenandthentryre-openingtheapp.IfWiFiicondoes
not appear refer to point 2.
a) Afterapowerfailure,AirTouch2willre-connecttohome
routerandWiFiicon(
)willbebackonin3minutesfrom
PowerON.
WiFi symbol (
)
disappeared from
the touchpad.
b) TurnthewirelessrouterOFFandturnitbackON.Waitfor3
minutesfortheAirTouch2systemtoinitialise.
c) IfWiFiicon(
)doesnotappear,followWiFisetupprocess
tore-establishconnectionbetweenyourhomerouterand
AirTouch2.
AirTouch 2 app does
not respond even if
the app is in
operation.
WiFiconnectionmayhavedroppedduetonoactionfromthe
mobile for a period of time.
a) ClosetheAirTouch2appandrestartit.
‘Send message error’
is displayed.
b) OrTurnthephoneoffandrestartit.
4
‘SPILL’ warning
message is displayed
Thismeansthatthespillfunctionhasbeenactivatedasasafety
measurebecausetoomanyzoneshavebeenturnedOFF.
TurningONmorezoneswillresolvetheissue.
5
‘SAFETY’ warning
message is displayed
Thismessagemeansthesafetyprotectionhasbeenactivated
duetoveryhighorlowtemperaturesreachedatthesupplyair
end.PleasechecktheACsystemtofixtheproblem.
6
‘HALF/ONE/TWO
YEAR SERVICE
DUE...’ message is
displayed
Thisisthemessageset-upbyyourinstallertoalertyoutoclean
yourfiltersorserviceyourair-conditionerevery6months,
1yearand2yearsrespectively.Thismessagecanberemoved
by touching the message area on the touchpad.
7
‘AC ERROR’, warning
message is displayed
ThiserroristriggeredduetoafaultwiththeACunitconnected
to.Pleasechecktheair-conditioningsystemtoresolvethe
issue.
*: Thesechecksshouldbecarriedoutbyqualifiedpersonnel.
If you have any doubt regarding the above please contact your installer.
20
ZONEMASTER AIRTOUCH 2 ZONE CONTROL SYSTEM - User Manual
9) Specifications
Electrical Requirements
Powersupply:
24VAC±10%
Linefrequency:
50Hz
Touchpad:
AirTouch
2
0.5VA
MainControlModule:
5VA System
Zone Control
Components Power Consumption
User Manual
Environmental Requirements
Operatingtemperature:
0°Cto60°C
Altitude:
0to2000meters
Operatingrelativehumidity: Avoidstaticelectricityhazards
10%to80%
Avoidelectromagneticradiationsources
Avoiddustcontamination
Avoidhighlycorrosiveenvironments
Outputvoltage:
24VAC,50Hz
Current:
200mA(1dampermotor)
InputVoltage:
240VAC,50Hz
OutputVoltage:
24VAC,50Hz
Wattage:
40W
Supply Air Sensor:
NTCtype,10kΩat25°C
Zone Output
Transformer
Battery:
3.0V,ML2032
RechargeableforMainModule
Fuse:
Dimension5x20mm,
Fast-Acting2A,250V
www.polyaire.com.au
©2016
Polyaire
Pty
Ltd
ZONEMASTER AIRTOUCH 2 ZONE CONTROL
SYSTEM
- User
Manual
21
POLYAIRE PTY LTD
11-13WHITEROAD
GEPPSCROSS
SOUTHAUSTRALIA,5094
TEL:(08)83498466
FAX:(08)83498446
www.polyaire.com.au
ZMAT2_USR_V2.0