A2 E3 Series and S3 Series Building Blocks - Gamewell-FCI

Transcription

A2 E3 Series and S3 Series Building Blocks - Gamewell-FCI
E3 Series® and S3 Series
Building Blocks Reference Guide
Document 9021-60764
03/23/2016
P/N 9021-60764:A2
Rev:
A2
Fire Alarm & Emergency Communication System Limitations
While a life safety system may lower insurance rates, it is not a substitute for life and property insurance!
An automatic fire alarm system—typically made up of smoke
detectors, heat detectors, manual pull stations, audible warning
devices, and a fire alarm control panel (FACP) with remote notification capability—can provide early warning of a developing fire.
Such a system, however, does not assure protection against
property damage or loss of life resulting from a fire.
An emergency communication system—typically made up of
an automatic fire alarm system (as described above) and a life
safety communication system that may include an autonomous
control unit (ACU), local operating console (LOC), voice communication, and other various interoperable communication methods—can broadcast a mass notification message. Such a
system, however, does not assure protection against property
damage or loss of life resulting from a fire or life safety event.
The Manufacturer recommends that smoke and/or heat
detectors be located throughout a protected premises following
the recommendations of the current edition of the National Fire
Protection Association Standard 72 (NFPA 72), manufacturer's
recommendations, State and local codes, and the
recommendations contained in the Guide for Proper Use of
System Smoke Detectors, which is made available at no charge
to all installing dealers. This document can be found at http://
www.systemsensor.com/appguides/. A study by the Federal
Emergency Management Agency (an agency of the United
States government) indicated that smoke detectors may not go
off in as many as 35% of all fires. While fire alarm systems are
designed to provide early warning against fire, they do not
guarantee warning or protection against fire. A fire alarm system
may not provide timely or adequate warning, or simply may not
function, for a variety of reasons:
Smoke detectors may not sense fire where smoke cannot
reach the detectors such as in chimneys, in or behind walls, on
roofs, or on the other side of closed doors. Smoke detectors also
may not sense a fire on another level or floor of a building. A second-floor detector, for example, may not sense a first-floor or
basement fire.
Particles of combustion or “smoke” from a developing fire
may not reach the sensing chambers of smoke detectors
because:
• Barriers such as closed or partially closed doors, walls, chimneys, even wet or humid areas may inhibit particle or smoke
flow.
• Smoke particles may become “cold,” stratify, and not reach
the ceiling or upper walls where detectors are located.
• Smoke particles may be blown away from detectors by air
outlets, such as air conditioning vents.
• Smoke particles may be drawn into air returns before reaching the detector.
The amount of “smoke” present may be insufficient to alarm
smoke detectors. Smoke detectors are designed to alarm at various levels of smoke density. If such density levels are not created by a developing fire at the location of detectors, the
detectors will not go into alarm.
Smoke detectors, even when working properly, have sensing
limitations. Detectors that have photoelectronic sensing chambers tend to detect smoldering fires better than flaming fires,
which have little visible smoke. Detectors that have ionizing-type
sensing chambers tend to detect fast-flaming fires better than
smoldering fires. Because fires develop in different ways and are
often unpredictable in their growth, neither type of detector is
necessarily best and a given type of detector may not provide
adequate warning of a fire.
Smoke detectors cannot be expected to provide adequate warning of fires caused by arson, children playing with matches
(especially in bedrooms), smoking in bed, and violent explosions
2
(caused by escaping gas, improper storage of flammable materials, etc.).
Heat detectors do not sense particles of combustion and alarm
only when heat on their sensors increases at a predetermined
rate or reaches a predetermined level. Rate-of-rise heat detectors may be subject to reduced sensitivity over time. For this reason, the rate-of-rise feature of each detector should be tested at
least once per year by a qualified fire protection specialist. Heat
detectors are designed to protect property, not life.
IMPORTANT! Smoke detectors must be installed in the same
room as the control panel and in rooms used by the system for
the connection of alarm transmission wiring, communications,
signaling, and/or power. If detectors are not so located, a developing fire may damage the alarm system, compromising its ability to report a fire.
Audible warning devices such as bells, horns, strobes,
speakers and displays may not alert people if these devices
are located on the other side of closed or partly open doors or
are located on another floor of a building. Any warning device
may fail to alert people with a disability or those who have
recently consumed drugs, alcohol, or medication. Please note
that:
• An emergency communication system may take priority over
a fire alarm system in the event of a life safety emergency.
• Voice messaging systems must be designed to meet intelligibility requirements as defined by NFPA, local codes, and
Authorities Having Jurisdiction (AHJ).
• Language and instructional requirements must be clearly disseminated on any local displays.
• Strobes can, under certain circumstances, cause seizures in
people with conditions such as epilepsy.
• Studies have shown that certain people, even when they hear
a fire alarm signal, do not respond to or comprehend the
meaning of the signal. Audible devices, such as horns and
bells, can have different tonal patterns and frequencies. It is
the property owner's responsibility to conduct fire drills and
other training exercises to make people aware of fire alarm
signals and instruct them on the proper reaction to alarm signals.
• In rare instances, the sounding of a warning device can cause
temporary or permanent hearing loss.
A life safety system will not operate without any electrical
power. If AC power fails, the system will operate from standby
batteries only for a specified time and only if the batteries have
been properly maintained and replaced regularly.
Equipment used in the system may not be technically compatible with the control panel. It is essential to use only equipment
listed for service with your control panel.
Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily disabled. For added protection against telephone line
failure, backup radio transmission systems are recommended.
The most common cause of life safety system malfunction is
inadequate maintenance. To keep the entire life safety system in
excellent working order, ongoing maintenance is required per the
manufacturer's recommendations, and UL and NFPA standards.
At a minimum, the requirements of NFPA 72 shall be followed.
Environments with large amounts of dust, dirt, or high air velocity
require more frequent maintenance. A maintenance agreement
should be arranged through the local manufacturer's representative. Maintenance should be scheduled as required by National
and/or local fire codes and should be performed by authorized
professional life safety system installers only. Adequate written
records of all inspections should be kept.
Limit-D2-2016
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
Installation Precautions
Adherence to the following will aid in problem-free installation with long-term reliability:
WARNING - Several different sources of power can be
connected to the fire alarm control panel. Disconnect all
sources of power before servicing. Control unit and associated equipment may be damaged by removing and/or inserting cards, modules, or interconnecting cables while the unit is
energized. Do not attempt to install, service, or operate this
unit until manuals are read and understood.
CAUTION - System Re-acceptance Test after Software
Changes: To ensure proper system operation, this product
must be tested in accordance with NFPA 72 after any programming operation or change in site-specific software. Reacceptance testing is required after any change, addition or
deletion of system components, or after any modification,
repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions known
to be affected by a change must be 100% tested. In addition,
to ensure that other operations are not inadvertently affected,
at least 10% of initiating devices that are not directly affected
by the change, up to a maximum of 50 devices, must also be
tested and proper system operation verified.
This system meets NFPA requirements for operation at 0-49º
C/32-120º F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful
life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature
ranges and humidity. Therefore, it is recommended that this
system and its peripherals be installed in an environment with
a normal room temperature of 15-27º C/60-80º F.
Verify that wire sizes are adequate for all initiating and indicating device loops. Most devices cannot tolerate more than a
10% I.R. drop from the specified device voltage.
Like all solid state electronic devices, this system may
operate erratically or can be damaged when subjected to lightning induced transients. Although no system is completely
immune from lightning transients and interference, proper
grounding will reduce susceptibility. Overhead or outside aerial
wiring is not recommended, due to an increased susceptibility
to nearby lightning strikes. Consult with the Technical Services Department if any problems are anticipated or encountered.
Disconnect AC power and batteries prior to removing or
inserting circuit boards. Failure to do so can damage circuits.
Remove all electronic assemblies prior to any drilling, filing,
reaming, or punching of the enclosure. When possible, make
all cable entries from the sides or rear. Before making modifications, verify that they will not interfere with battery, transformer, or printed circuit board location.
Do not tighten screw terminals more than 9 in-lbs. Overtightening may damage threads, resulting in reduced terminal
contact pressure and difficulty with screw terminal removal.
This system contains static-sensitive components.
Always ground yourself with a proper wrist strap before handling any circuits so that static charges are removed from the
body. Use static suppressive packaging to protect electronic
assemblies removed from the unit.
Follow the instructions in the installation, operating, and programming manuals. These instructions must be followed to
avoid damage to the control panel and associated equipment.
FACP operation and reliability depend upon proper installation.
Precau-D1-9-2005
FCC Warning
WARNING: This equipment generates, uses, and can
radiate radio frequency energy and if not installed and
used in accordance with the instruction manual may
cause interference to radio communications. It has been
tested and found to comply with the limits for class A
computing devices pursuant to Subpart B of Part 15 of
FCC Rules, which is designed to provide reasonable
protection against such interference when devices are
operated in a commercial environment. Operation of this
equipment in a residential area is likely to cause interference, in which case the user will be required to correct
the interference at his or her own expense.
Canadian Requirements
This digital apparatus does not exceed the Class A limits
for radiation noise emissions from digital apparatus set
out in the Radio Interference Regulations of the Canadian Department of Communications.
Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la classe A prescrites dans le
Reglement sur le brouillage radioelectrique edicte par le
ministere des Communications du Canada.
eVance™ is a trademark; and Acclimate®, FocalPoint®, Gamewell-FCI®, FAAST Fire Alarm Aspiration Sensing Technology®, Intelligent FAAST®,
SmartScan®, SWIFT®, Velociti®, and E3 Series® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered
trademarks of the Microsoft Corporation. Chrome™ and Google™ are trademarks of Google Inc.
©2016 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
3
Software Downloads
In order to supply the latest features and functionality in fire alarm and life safety technology to our customers, we make
frequent upgrades to the embedded software in our products. To ensure that you are installing and programming the latest
features, we strongly recommend that you download the most current version of software for each product prior to
commissioning any system. Contact Technical Support with any questions about software and the appropriate version for a
specific application.
Documentation Feedback
Your feedback helps us keep our documentation up-to-date and accurate. If you have any comments or suggestions about our
online Help or printed manuals, you can email us.
Please include the following information:
•Product name and version number (if applicable)
•Printed manual or online Help
•Topic Title (for online Help)
•Page number (for printed manual)
•Brief description of content you think should be improved or corrected
•Your suggestion for how to correct/improve documentation
Send email messages to:
[email protected]
Please note this email address is for documentation feedback only. If you have any technical issues, please contact Technical
Services.
4
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
Table of Contents
Section 1: Basic E3 Series Remote Configurations .............................................................. 6
1.1: E3 Series Remote Annunciator, E3BB-BAA1 Cabinet Ordering Information .............................................7
1.2: E3 Series Remote Annunciator, E3BB-BA2 Cabinet Ordering Information ................................................8
1.3: E3 Series Remote Annunciator, E3BB-FLUSH-LCD Cabinet Ordering Information..................................9
1.4: E3 Remote Annunciator, E3BB-NGA-FLUSH Cabinet Ordering Information..........................................10
1.5: E3 Series Remote Annunciator, E3BB-BAA with E3ID2-A Inner Door Cabinet Ordering Information...11
1.6: E3 Series Remote Annunciator, RAN-7100 Cabinet Ordering Information ...............................................12
1.7: KDU-Retrofit Cabinet Ordering Information ..............................................................................................13
Section 2: E3/S3 Series FACP Panel Configurations .......................................................... 14
2.1: E3 Series B-Slim Cabinet Ordering Information.........................................................................................15
2.2: E3 Series “B” Size Cabinet Ordering Information ......................................................................................16
2.3: E3 Series “C” Size Cabinet Ordering Information ......................................................................................17
2.4: E3 Series Fire/Audio “C” Size Cabinet Ordering Information ...................................................................18
2.5: E3 Series “D” Size Cabinet Ordering Information......................................................................................19
2.6: S3-Slim Cabinet Ordering Information .......................................................................................................20
Section 3: Basic E3 Series In-Building Mass Notification Cabinet Configurations.......... 21
3.1: E3 Series ACU “C” Size Cabinet used for Combination Fire/MNS System (NGA Display) Ordering
Information .........................................................................................................................................................22
3.2: E3 Series ACU “D” Size Cabinet used for Combination Fire/MNS System (NGA Display) Ordering
Information .........................................................................................................................................................23
Section 4: Basic E3 Series In-Building Mass Notification LOC Configurations ............... 24
4.1: E3 Series LOC Local Operating Console Ordering Information ................................................................25
4.2: E3 Series LOC-TEL Local Operating Console Ordering Information........................................................26
Section 5: Basic E3 Series Audio Transponder Cabinet Configurations .......................... 27
5.1: E3 Series INX CAB-B Cabinet Ordering Information................................................................................28
5.2: E3 Series INX CAB-C Cabinet Ordering Information................................................................................29
5.3: E3 Series INX CAB-D Cabinet Ordering Information................................................................................30
Section 6: E3 Series Classic Bulk Audio Cabinet Configurations ..................................... 31
6.1: E3 Series Classic, SBB-C4 Cabinet Ordering Information .........................................................................32
6.2: E3 Series Classic SBB-D4 Ordering Information .......................................................................................33
Section 7: Retrofit Kit Cabinets ............................................................................................. 34
7.1: IF600-Retrofit Backbox Ordering Information ...........................................................................................35
7.2: 600XL Retrofit Backbox Ordering Information..........................................................................................36
7.3: 7200 Retrofit Kit “B” Size Backbox Ordering Information ........................................................................37
7.4: 7200 Retrofit Kit “C” Size Backbox Ordering Information ........................................................................38
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
5
Basic E3 Series Remote Configurations
Section 1: Basic E3 Series Remote Configurations
3
8¾
E3BB-BAA1
10
3
1 3 ¼
L C
D E 3
1 0
L C
D S L
P
E3BB-BA2
3
1 3 ¼
L C
D E
E3BB-FLUSH-LCD
1 0
3
L C
D S
L P
4½
13¼
15¼
12
R P
T -E
E3BB-NGA-FLUSH
3 -U
TP
10
4
1 /2
1 9
L C
D
- E
3
E3BB-BAA/E3ID-2
1 / 4
1 0
L C
D
- S L
P
/2
2 1
1 0
RAN-7100
5 1 /4
R A
N 71
00
KD
U
KD
U
KDU Retrofit
RA
N71
0
6
RE
TR
O F
IT
BA
CK
BO
X
CO
VE
R
0
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
E3 Series Remote Annunciator, E3BB-BAA1 Cabinet Ordering Information
Basic E3 Series Remote Configurations
1.1 E3 Series Remote Annunciator, E3BB-BAA1 Cabinet
Ordering Information
The E3BB-BAA1 model is a single module remote annunciator cabinet that houses any one of the
following:
• NGA
• ASM-16
• Microphone
Table 1.1.1 lists the components that can be ordered for the E3 Series Remote Annunciator
E3BB-BAA1 cabinet.
Figure 1.1.1 E3 Series Remote
Figure 1.1.2 E3 Display Remote
Annunciator with NGA Display
Annunciator with ASM-16
Figure 1.1.3 shows the E3BB-BAA1 cabinet installation configuration.
3
8 3 /4
10
Figure 1.1.3
Qty
Part Number
E3 Remote Annunciator E3BB-BAA1 Cabinet Configuration
Model Number
Description
List
Price
Note: X represents the required components.
X
Cabinets
Dimensions:
E3BB-BAA1
8 3/4”W x 10”H x 3”D
Enclosure, black, “AA1” with key lock
E3BB-RAA1
8 3/4”W x 10”H x 3”D
Enclosure, red, “AA1” with key lock
Shipped with 1 slot Inner Door
Modules
X
1100-0505
NGA
NGA, Network Graphic Annunciator
X
RPT-E3-UTP
Repeater
Network Repeater, unshielded twisted pair
1100-0455
ASM-16
Programmable Switch Module
1100-0452
MIC
INCC-MIC, Paging Microphone
FSL-E3
Fiber module
Single mode fiber module
FML-E3
Fiber module
Multi mode fiber module
90492
90492 Thumb lock
Thumb quarter turn latch
Optional Components
E3-TRIMKIT-A1
Trim Ring Kit
Table 1.1.1 E3 Remote Annunciator E3BB-BAA1 Cabinet Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
7
Basic E3 Series Remote Configurations
E3 Series Remote Annunciator, E3BB-BA2 Cabinet Ordering Information
1.2 E3 Series Remote Annunciator, E3BB-BA2 Cabinet
Ordering Information
The E3BB-BA2 model is a single module remote annunciator cabinet that houses either the LCDE3 or the LCD-SLP. Table 1.2.1 lists the components that can be ordered for the E3 Series Remote
Annunciator E3BB-BA2 cabinet.
NOTE: In the E3BB-BA2 cabinet, you can install either the LCD-E3 or the LCD-SLP display.
Figure 1.2.1 E3 Series Remote
Annunciator with LCD-E3 Display
Figure 1.2.2 E3 Series Remote
Annunciator with LCD-SLP Display
Figure 1.2.3 shows the E3BB-BA2 cabinet installation configuration.
3
1 3 ¼
L C
D E 3
1 0
L C
D S L
P
Figure 1.2.3
Qty
Part Number
E3 Remote Annunciator E3BB-BA2 Cabinet Configuration
Model Number
Description
List
Price
Note: X represents the required components.
Cabinets
1
Dimensions:
E3BB-BA2
13 1/4”W x 10”H x 3”D
Enclosure, black, “AA1” with key lock
E3BB-RA2
13 1/4”W x 10”H x 3”D
Enclosure, red, “AA1” with key lock
Shipped with 1 slot Inner Door
Modules
X
LCD-SLP
Display
LCD Touch screen display unit
LCD-E3
Display
LCD keypad display
90492 Thumb lock
Thumb quarter turn latch
Optional Components
90492
E3-TRIMKIT-A2 E3 TRIMKIT
Trim Ring Kit
Table 1.2.1 E3 Remote Annunciator E3BB-BA2 Cabinet Ordering Information
8
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
E3 Series Remote Annunciator, E3BB-FLUSH-LCD Cabinet Ordering Information
Basic E3 Series Remote Configurations
1.3 E3 Series Remote Annunciator, E3BB-FLUSH-LCD
Cabinet Ordering Information
The E3BB-FLUSH-LCD model is a single module flush remote annunciator cabinet that houses
either the LCD-E3 or the LCD-SLP. Table 1.3.1 lists the components that can be ordered for the E3
Series Remote Annunciator E3BB-FLUSH-LCD cabinet.
NOTE: In the E3BB-FLUSH-LCD cabinet, you can install the LCD-E3 or the LCD-SLP display.
Figure 1.3.1 E3 Series Remote
Annunciator with LCD-E3 Display
Figure 1.3.2
E3 Remote Annunciator
with LCD-SLP
Figure 1.3.3 shows the E3BB-FLUSH-LCD cabinet installation configuration.
3
13¼
LC
Figure 1.3.3
Qty
Part Number
D-
10
E3
LC
D-
SL
P
E3 Remote Annunciator E3BB-FLUSH-LCD Cabinet Configuration
Model Number
Description
List
Price
Note: X represents the required components.
Cabinet
X
Dimensions:
E3BB-FLUSH-LCD 13 1/4”W x 10”H x 3”D
Flush Enclosure, black, with key lock
Modules
X
LCD-SLP
Display
LCD Touch screen display unit
LCD-E3
Display
LCD keypad display
Optional Components
Table 1.3.1 E3 Remote Annunciator E3BB-FLUSH-LCD Cabinet Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
9
Basic E3 Series Remote Configurations
E3 Remote Annunciator, E3BB-NGA-FLUSH Cabinet Ordering Information
1.4 E3 Remote Annunciator, E3BB-NGA-FLUSH Cabinet
Ordering Information
The E3BB-NGA-FLUSH model is a single module, flush remote annunciator cabinet that houses
the NGA. Table 1.4.1 lists the components that can be ordered for the E3 Series Remote Annunciator E3BB-NGA-FLUSH.
Figure 1.4.1 E3 Series Remote Annunciator with LCD-E3 Display
Figure 1.4.2 shows the E3BB-NGA-FLUSH cabinet configuration.
/2
4 1
”
1 3 1 /4 ”
15 ¼ ”
12”
RP
NG
T -E
A
3 -U
TP
10”
Figure 1.4.2
Qty
Part Number
E3 Remote Annunciator E3BB-NGA-FLUSH Cabinet Configuration
Model Number
Description
List
Price
Note: X represents the required components.
Cabinet
1
Dimensions:
E3BB-NGA-FLUSH 13 1/4”W x 10”H x 4 1/2”D
Flush Enclosure, black,
Modules
X
1100-0505
NGA Annunciator
Network graphic annunciator
X
RPT-E3-UTP
Network repeater
Network repeater, unshielded twisted-pair
FSL-E3
Single mode
Fiber loop module, Single mode
FML-E3
Multi mode
Fiber loop module, Multi mode
Optional Components
Table 1.4.1 E3 Remote Annunciator E3BB-NGA-FLUSH Cabinet Ordering Information
10
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
E3 Series Remote Annunciator, E3BB-BAA with E3ID2-A Inner Door Cabinet Ordering Information
Basic E3 Series Remote
1.5 E3 Series Remote Annunciator, E3BB-BAA with E3ID2-A
Inner Door Cabinet Ordering Information
The E3BB-BAA with E3ID2-A Inner Door model is a double module, remote annunciator cabinet
that is used for display and control. It houses the LCD-E3 or LCD-SLP and an ASM-16.
Table 1.5.1 lists the components that can be ordered for the E3 Series Remote Annunciator E3BBBAA cabinet. .
NOTE: In the E3BB-BAA-E3ID2-A cabinet, you can install either the LCD-E3 or LCD-SLP.
Figure 1.5.2 E3 Series Remote
Figure 1.5.1 E3 Series Remote
Annunciator with LCD-SLP Display and
Annunciator with LCD-E3 Display and
ASM-16
ASM-16
Figure 1.5.3 shows the E3BB-BAA with the E3ID2-A inner door cabinet configuration.
/2
4 1
1 9
L C
D -E
3
1 /4
L C
D -S
L P
Figure 1.5.3
Qty
Part Number
1 0
E3 Remote Annunciator E3BB-BAA with E3ID2-A Cabinet
Configuration
Model Number
Description
List Price
Note: X represents the required components.
1
Cabinets
Dimensions:
E3BB-BAA
19”W x 10”H x 4 1/2”D
LOC Enclosure, black
E3BB-RAA
19”W x 10”H x 4 1/2”D
LOC Enclosure, red
E3ID2-A
Modules
X
LCD-E3
LCD Keypad Display
LCD-SLP
LCD Touch screen display
1100-0455
ASM-16 programmable switch module
Optional Components
90492
Thumb latch
Quarter turn thumb latch
E3-TRIMIT-A
Table 1.5.1 E3 Remote Annunciator E3BB-BAA with E3ID-2 Cabinet Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
11
Basic E3 Series Remote Configurations
E3 Series Remote Annunciator, RAN-7100 Cabinet Ordering Information
1.6 E3 Series Remote Annunciator, RAN-7100 Cabinet
Ordering Information
The RAN-7100 model is a double module, remote annunciator cabinet that is used for display and
control. Figure 1.6.1 illustrates the remote serial annunciator, LCD display for the Gamewell RAN
retrofit. This model is installed in the GWRAN2-BB backbox.
Figure 1.6.1 E3 Series Remote Annunciator, RAN-7100 Display Panel
Figure 1.6.2 shows the RAN-7100 cabinet installation configuration.
”
2 ½
10
RA
N71
0
0
5 ¼ ”
Figure 1.6.2
Qty
Part Number
E3 Remote Annunciator RAN-7100 Cabinet Configuration
Model Number
Description
List
Price
Note: X represents the required components.
Cabinets
Dimensions:
1
RAN-7100
10”W x 5 1/4”H x 2 1/2’D
1
GWRAN2-BB
Remote Alpha-numeric display
Backbox
Module
Optional Components
Table 1.6.1 E3 Remote Annunciator RAN-7100 Cabinet Ordering Information
12
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
KDU-Retrofit Cabinet Ordering Information
Basic E3 Series Remote Configurations
1.7 KDU-Retrofit Cabinet Ordering Information
The KDU-Retrofit model is a single module retrofit cabinet that houses the LCD display for the
Gamewell RAN, FCI KDU retrofits. Figure 1.7.1 illustrates the KDU-Retrofit cabinet
configuration.
2 5/8"
18"
6"
Figure 1.7.1 KDU-Retrofit Remote Annunciator Cabinet Configuration
Qty
Part Number
Model Number
Description
List
Price
Kit includes the following:
1
Cabinet
Dimensions
KDU-RETROFIT
18”W x 2.5/8”H x 6”D
Includes the mounting plate for the existing
remote KDU backbox.
This Kit requires the following:
1
RAN-7100
Annunciator
Remote serial annunciator, LCD display
Optional Components
Table 1.7.1 KDU Retrofit Remote Annunciator Cabinet Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
13
Section 2: E3/S3 Series FACP Panel Configurations
LC
D-
IL
IL I I - M B
95
-M -E 3 /
BE3
E3
LC
-
AC
POW E
R
ON
POW E
R
FAULT
ALARM
ACKNOWLED
GE
E3BB-RBSLIM
ME
NU
GROU
ND
FAULT
TROUBLE
ACKNOWLED
GE
SYSTE
M
TR OU
BLE
ALAR
M
SIGNAL
SILENCE
BACKSPA
CE/
EDIT
SUPERVIS
O RY
SL
P
PM
P M -9 /
-9 G
SYSTEM
RESET/
LAMP TEST
OK/
ENTER
LC
KE D-E3
YP
AD
E3BB-BB “B” CAB
D-
SYSTE
M
SILENC
ED
AS
M16
CABINET B
ILI
ILI9 -MB5-M E3/
B-E
3
DA
CT
-E3
RP
T-E
3
PM
PM -9/
-9G
CA
IN BIN
NE E
R TB
DO ,
OR
BA
TTE
RIE
S
DA
CT
-E
LC
KE D-E 3
YP
AD
AS
M-1
3
RP
T-E
3
IL
ILI9 I-MB
5-M -E3
B-E /
3
6
PM
BL
E3BB-BC/INCC “C” CAB
AN
KP
LA
TE
IL
ILI9 I-S-E
5-S 3/
-E
3
BLA
PLA N K
TE
-9/P
M -9
G
IL
ILI9 I-S-E
5-S 3/
-E
3
BA
DA
NG
A
CT
TT
IL
IL I9 I-M B
5 -M -E 3
BE3
-E
3
RP
T -E
ER
CA
IE S
BI
NE
T
C
3
P
P M M -9 /
-9
G
-
E3BB-BC/INCC “C” CAB
AUDIO
TE
LE
PH
ON
IN IEB
O
VG
X
AM
-5 0
SE
R IE
S
CA
E X B IN E
TE
ND T C
ER
P
A
S E M -5 0
R IE
S
DA
LC
D IS D -E
PL 3
AY
AS
M -1
C T-
E3
RP
PM
6
IL I-
T -E
LA
TE
3
-9 /P
M
- -9 G
S -E 3/
O R IL I95S -E
AN
X
3
IL I-S
-E 3/ O R IL I9 5-S
AN
X -E 3
E3BB-BD/INCC “D” CAB
IL I-
D A C T -E 3
R P T-E 3-U T P
S -E
3/
O R IL I9 5S- E
AN
X
3
”
4½
1 4 1 /8 "
S L C -P M
L C D -S L P
S LC -P M /S L C 95-P M #1
S LC -P M /S L C 95-P M #2
S L P -E 3
S3 SLIM CAB
2 0 1 /8 "
F L P S -7
14
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
E3 Series B-Slim Cabinet Ordering Information
E3/S3 Series FACP Panel Configurations
2.1 E3 Series B-Slim Cabinet Ordering Information
The E3 Series B-Slim Cabinet is used to house the components that support the E3 Series Fire
Evacuation System. Figure 2.1.1 illustrates the E3 Series, B-Slim Cabinet configuration.
Table 2.1.1 lists the E3 Series, B-Slim cabinet ordering information.
IL
ILI I-MB
95 -E
-M 3/
BE3
LC
DE3
-
AC
POWE
R
ON
POWE
R
FAULT
GROU
ND
FAULT
ALARM
TROUBLE
ACKNOWLED ACKNOWLED
GE
GE
ME
NU
SUPERVIS SYSTE
M
ORY
SILENC
ED
SYSTEM
RESET/
LAMP TEST
SIGNAL
SILENCE
BACKSPA
CE/
EDIT
SYSTE
M
TROU
BLE
ALAR
M
LC
DSL
P
PM
PM -9/
-9G
OK/
ENTER
Figure 2.1.1 E3 Series, B-Slim Cabinet Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents required components.
Cabinet
Dimensions:
E3BB-RBSLIM
20 1/8”H x 14 1/8”W x 4 1/2”D
E3BB-RBSLIM Enclosure, Red, Narrow
ILI-MB-E3
System Sensor
Intelligent Loop Interface, Mother Board (max-1)
ILI-S-E3
System Sensor
Intelligent Loop Interface, Supplemental (max-1)
ILI95-MB-E3
Apollo Sensor
Intelligent Loop Interface, Mother Board (max-1)
ILI95-S-E3
Apollo Sensor
Intelligent Loop Interface, Supplemental (max-1)
X
PM-9
Power Supply
9 Ampere Power Supply
X
LCD-E3
Display
LCD Keypad Display
X
2 Batteries
DACT-E3
DACT
Digital Alarm Communiocation Transmitter
RPT-E3-UTP
Networking Card
Network Repeater, Unshielded Twisted-Pair
FSL-E3
Fiber Networking
Fiber Network Module, Single-Mode Fiber, 1
Channel
FML-E3
Fiber Networking
Fiber Network Module, Multi-Mode Fiber, 1
Channel
90516
7 A/H Seismic
7 A/H Seismic Battery Bracket Kit
90517
12 A/H Seismic
12 A/H Seismic Battery Bracket Kit
75687
Cable
20” Repeater Cable needed for RPT-E3-FO
75687-A Special Order Cable
X
Modules
X
Optional Components
Table 2.1.1 E3 Series, B-Slim Cabinet Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
15
E3/S3 Series FACP Panel Configurations
E3 Series “B” Size Cabinet Ordering Information
2.2 E3 Series “B” Size Cabinet Ordering Information
The E3 Series “B” Size Cabinet is used to house the components that support the E3 Series Fire
Evacuation System. Figure 2.2.1 illustrates the E3 Series, “B” Size cabinet configuration.
Table 2.2.1 lists the E3 Series, “B” Size cabinet ordering information.
LC
KE D-E3
YP
AD
CA
INN BIN
ER ET
DO B,
OR
AS
M16
DA
CT
-E3
CABINET B
ILI
ILI9 -MB5-M E3/
B-E
3
RP
T-E
3
PM
PM -9/
-9G
BA
TT
ER
IES
Figure 2.2.1 E3 Series “B” Size Cabinet Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents required components.
X
X
Cabinet
Dimensions:
E3BB-BB
19 3/8”W X 19 3/8”H X 4 1/2”D E3 Enclosure, Black, “B” Size
E3BB-RB
19 3/8”W X 19 3/8”H X 4 1/2”D E3 Enclosure, Red, “B” Size
E3ID2-B
Inner Door
Inner Door, 2 Slot, “B” Size
LCD-E3
Display
LCD Keypad Display
LCD-SLP
Display
LCD Touchscreen Display
Modules
X
X
PM-9
Power Supply
9 Ampere Power Supply
X
ILI-MB-E3
System Sensor
Intelligent Loop Interface, Mother Board
ILI95-MB-E3
Apollo Sensor
Intelligent Loop Interface, Mother Board
X
2-Batteries
Maximum 18 AH Capacity
Optional Components
1100-0450
Inner Door Blank Plate
Single Size Inner Door Blank Plate
(Pack of three Plates)
1100-0455
Switch Module
ASM-16 Programmable Switch Module (max-1)
DACT-E3
DACT
Digital Alarm Communication Transmitter
RPT-E3-UTP
Networking Card
Network Repeater, Unshielded Twisted-Pair
FSL-E3
Fiber Networking
Fiber Network Module, Single-Mode Fiber, 1
Channel
FML-E3
Fiber Networking
Fiber Network Module, Multi-Mode Fiber, 1
Channel
90518
7 A/H Seismic
7 A/H Seismic Battery Bracket Kit
90520
18 A/H Seismic
18 A/H Seismic Battery Bracket Kit
E3-TRIMKIT-B
E3 Cabinet B, Trim Rings
Table 2.2.1 E3 Series “B” Cabinet Ordering Information
16
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
E3 Series “C” Size Cabinet Ordering Information
E3/S3 Series FACP Panel Configurations
2.3 E3 Series “C” Size Cabinet Ordering Information
The E3 Series “C” Size Cabinet is used to house the components that support the E3 Series Fire
Evacuation System. Figure 2.3.1 illustrates the E3 Series, “C” Size cabinet configuration.
Table 2.3.1 lists the E3 Series, “C” Size cabinet ordering information.
DA
LC
KE D-E3
YP
AD
AS
M-
CT
-E3
RP
T-E
3
16
PM
-9/P
BL
AN
K
PL
A
TE
BL
A
PL NK
AT
E
CA
IL
ILI I-MB
95
-M -E3/
BE3
IL
ILI I-S-E
95
-S 3/
-E
3
BI
NE
TC
M-9
G
IL
IL I I-S-E
95
-S 3/
-E
3
BA
TT
ER
IE S
Figure 2.3.1 E3 Series “C” Size Cabinet Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents required components.
X
Cabinet
Dimensions:
E3BB-BC/INCC
30”H x 19 3/8”W x 4 1/2”D
E3 Enclosure, Black, “C” Size
E3BB-RC/INCC 30”H x 19 3/8”W x 4 1/2”D
E3 Enclosure, Red, “C” Size
X
E3-ILI-CPLATE
Used for FACP
Intelligent Loop Module Mounting Plate
X
E3ID2-C
Used for LCD-E3
Inner Door, 2 Slot, “C” Size
E3ID3-C
Used with NGA
Inner Door, 3 Slot, “C” Size
LCD-E3
Display
LCD Keypad Display
LCD-SLP
Display
LCD Touchscreen Display
Modules
X
X
X
X
1100-0505
NGA
Network Graphic Annunciator
PM-9
Power Supply
9 Ampere Power Supply
ILI-MB-E3
System Sensor
Intelligent Loop Interface, Mother Board (max-1)
ILI-S-E3
System Sensor
Inteligent Loop Interface, Supplemental (max-2)
ILI95-MB-E3
Apollo Sensor
Intelligent Loop Interface, Mother Board (max-1)
ILI95-S-E3
Apollo Sensor
Intelligent Loop Interface, Supplemental (max-2)
2-Batteries
Maximum 18 AH Capacity
Optional Components
E3-BP
Inner Door Blank Plate
Double Size Inner Door Blank Plate
(Pack of one Plate)
1100-0450
Inner Door Blank Plate
Single Size Inner Door Blank Plate
(Pack of three Plates)
1100-0455
Switch Module
ASM-16 Programmable Switch Module
DACT-E3
DACT
Digital Alarm Communication Transmitter
RPT-E3-UTP
Networking Card
Network Repeater, Unshielded Twisted-Pair
FLS-E3
Fiber Networking
Fiber Network Module, Single-Mode Fiber, 1
Channel
FML-E3
Fiber Networking
Fiber Network Module, Multi-Mode Fiber, 1 Channel
90518
7 A/H Seismic
7 A/H Seismic Battery Bracket Kit
90520
18 A/H Seismic
18 A/H Seismic Battery Bracket Kit
E3-TRIMKIT-C
E3 Cabinet C, Trim Rings
Table 2.3.1 E3 Series “C” Size Cabinet Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
17
E3/S3 Series FACP Panel Configurations
E3 Series Fire/Audio “C” Size Cabinet Ordering Information
2.4 E3 Series Fire/Audio “C” Size Cabinet Ordering
Information
The E3 Series “C” Size Cabinet is used to house the components and amplifiers that support the E3
Series Fire and Voice Evacuation Systems. Figure 2.4.1 illustrates the E3 Series Fire/Audio “C”
Size cabinet configuration. Table 2.4.1 lists the E3 Series Fire/Audio, “C” Size cabinet ordering
information.
IL
IL I I- M B
95
-M -E 3
BDA
E3
CT
CA
-E 3
NG
RP
A
T -E
BI
NE
T
C
3
P
P M M-9
-9 /
G
-
TE
LE
PH
ON
IN
EB
O
I- V
G
X
AM
-5 0
SE
R IE
S
CA
E X B IN E
TE
ND T C
ER
P
AM
S E -5 0
R IE
S
LA
TE
Figure 2.4.1 E3 Series Fire/Audio “C” Size Cabinet Configuration
Qty
Part Number
Model Number
Description
List
Price
Note 1: X represents required components.
Note 2: If you use the AM-50 Plate, you must install a separate battery box to house the system batteries.
Cabinet
E3BB-BC/INCC
E3-INCC-C PLATE
E3ID2-C
LCD-E3
LCD-SLP
X
1100-0452
1100-0455
1100-0451
X
ILI-MB-E3
ILI95-MB-E3
X
PM-9
1100-1323
X
1100-1324
X
AM-50-Plate
1100-0456
AM-50-70
Optional Components
X
X
X
X
Dimensions:
30”H x 19 3/8”W x 4 1/2”D
Mounting Plate
2 Slots Door
Display
Display
MIC
ASM-16
INCC-TEL
System Sensor
Apollo Sensor
Power Supply
INI-VGX-FO
INI-VGX-UTP
AM-50 Extender Plate
AM-50-25
70V Amp
90521
E3-TRIMKIT-C
DACT-E3
RPT-E3-UTP
FSL-E3
Line Filter
DACT
Networking Card
Fiber Networking
FML-E3
E3-BP
1100-0450
Fiber Networking
Inner Door Blank Plate
Inner Door Blank Plate
Enclosure, Command Center Black, “C” Size
Command Center Mounting Plate, “C” Size
Inner Door, Command Center, 2 Slots “C” Size
LCD Keypad Display
LCD Touchscreen Display
INCC-MIC, Paging Microphone
Programmable Switch Module
Command Center Firefighter Telephone Module
Intelligent Loop Interface, Mother Board
Intelligent Loop Interface, Mother Board
9 Ampere Power Supply
Transponder Voice Gateway Fiber-Optic
Transponder Voice Gateway Twisted-Pair Wire
Amplifier Extender Plate (Supports One AM-50)
AM-50 Watt Amplifier (max-1)
70V 50 Watt amplifier (max-1)
AC Line Filter Required with 70V Amplifier
Trim Ring Kit
Digital Alarm Communication Transmitter
Network Repeater, Unshielded Twisted-Pair Wire
Fiber Network Module, Single-Mode Fiber,1
Channel
Fiber Network Module, Multi-Mode Fiber, 1 Channel
Double Size Inner Door Blank Plate (Pack of 1 Plate)
Single Size Inner Door Blank Plate (Pack of 3 Plates)
Table 2.4.1 E3 Series Fire/Audio “C” Size Cabinet Ordering Information
18
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
E3 Series “D” Size Cabinet Ordering Information
E3/S3 Series FACP Panel Configurations
2.5 E3 Series “D” Size Cabinet Ordering Information
The E3 Series “D” Size Cabinet is used to house the components that support the E3 Series Fire
Evacuation System. Figure 2.5.1 illustrates the E3 Series, “D” Size cabinet configuration.
Table 2.5.1 lists the E3 Series, “D” Size cabinet ordering information.
DA
C
E 3 TRP
Y
T -E
3
PM
P M - 9/
-9
G
LC
D I D -E3
SP
LA
IL
ILI9 I- S - E
3
5
S E -S -E ,
O R R IE 3
AN S
X
IL
IL I I- S - E
9
3
S E 5- S- E ,
O R R IE S 3
AN
X
IL
I LI I- S - E
95
3
S E - S- E ,
O R RIE S 3
AN
X
Figure 2.5.1 E3 Series “D” Size Cabinet Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents required components.
X
Cabinet
Dimensions:
E3BB-BD/INCC
41”H x 19 3/8”W x 4 1/2”D
E3 Enclosure, Black, “D” Size
E3BB-RD/INCC 41”H x 19 3/8”W x 4 1/2”D
E3 Enclosure, Red, “D” Size
X
E3-INCC-D PLATE
Back Plate used for FACP or Command Center
X
E3ID2-D
Used for LCD-E3
Inner Door, 2 Slot, “D” Size
E3ID3-D
Used with NGA
Inner Door, 3 Slot, “D” Size
LCD-E3
Display
LCD Keypad Display
LCD-SLP
Display
LCD Touchscreen Display
Modules
X
1100-0505
NGA
Network Graphic Annunciator
X
PM-9
Power Supply
9 Ampere Power Supply
X
ILI-MB-E3
System Sensor
Intelligent Loop Interface, Mother Board (max-1)
ILI-S-E3
System Sensor
Inteligent Loop Interface, Supplemental (max-6)
X
ILI95-MB-E3
Apollo Sensor
Intelligent Loop Interface, Mother Board (max-1)
ILI95-S-E3
Apollo Sensor
Intelligent Loop Interface, Supplemental (max-6)
2-Batteries
Maximum 18 AH Capacity
Optional Components
E3-BP
Inner Door Blank Plate
Double Size Inner Door Blank Plate (Pack of 1 Plate)
1100-0450
Inner Door Blank Plate
Single Size Inner Door Blank Plate (Pack of 3 Plates)
1100-0455
Switch Module
ASM-16 Programmable Switch Module
DACT-E3
DACT
Digital Alarm Communication Transmitter
RPT-E3-UTP
Networking Card
Network Repeater, Unshielded Twisted-Pair
FSL-E3
Fiber Networking
Fiber Network Module, Single-Mode Fiber,1 Channel
FML-E3
Fiber Networking
Fiber Network Module, Multi-Mode Fiber,1 Channel
90518
7 A/H Seismic
7 A/H Seismic Battery Bracket Kit
90520
18 A/H Seismic
E3-TRIMKIT-D
18 A/H Seismic Battery Bracket Kit
E3 Cabinet D, Trim Rings
Table 2.5.1 E3 Series “D” Size Cabinet Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
19
E3/S3 Series FACP Panel Configurations
S3-Slim Cabinet Ordering Information
2.6 S3-Slim Cabinet Ordering Information
The S3-Slim Cabinet is used to house the modules that support the S3 Series Small Addressable
Fire Alarm Control Panel System. Figure 2.6.1 illustrates the S3-Slim cabinet configuration.
Table 2.6.1 lists the components that can be ordered for the S3 Slim cabinet.
DACT-E3
RPT-E3-UTP
”
4½
14 1/8"
SLC-PM
LCD-SLP
SLC-PM/SLC95-PM #1
SLC-PM/SLC95-PM #2
SLP-E3
20 1/8"
FLPS-7
Figure 2.6.1 S3 Slim Cabinet
Qty
Part Number
Model Number
Description
List
Price
Note: X represents the required components.
X
X
X
Cabinets
Dimensions:
SLP-BLK
14 1/8”W x 20 1/8”H x 4 1/2”D Smart Loop Panel Addressable FACP in black
enclosure.
SLP-RED
14 1/8”W x 20 1/8”H x 4 1/2”D Smart Loop Panel Addressable FACP in red
enclosure.
SLC-PM
System Sensor SLC module
Velociti SLC loop 318 devices. Requires 1 or 2
devices used for SLC loops.
SLC95-PM
Apollo SLC module
Apollo SLC loop 126 devices. Requires 1 or 2
devices used for SLC loops.
LCD-SLP
S3 Main Display
LCD Touch screen display unit
(shipped with SLP-BLK).
FLPS-7-RB
7 amp Power Supply
Power Supply unit (shipped with SLP-BLK)
2 Batteries
12 A/H Batteries
Optional Components
DACT-E3
Dialer
Digital Alarm Communication Transmitter
RPT-E3-UTP
Networking Card
Network repeater, unshielded twisted-pair
FSL-E3
Fiber Networking
Fiber Network Module, Single-Mode Fiber,
1 channel
FML-E3
Fiber Networking
Fiber Network Module, Multi-Mode Fiber,
1 channel
Table 2.6.1 S3-Slim Cabinet Ordering Information
20
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
Section 3: Basic E3 Series In-Building Mass
Notification Cabinet Configurations
IL
ILI I-MB
95
-M -E3
BE3
DA
CT
-E3
RP
T-E
3
NG
A
E3BB-BC/INCC “C” CAB
COMBINATION
FIRE/ACU
CA
BI
NE
T
C
P
PM M-9
-9 /
G
-
TE
LE
PH
ON
EB
OX
INIVG
SE
RIE
S
AM
-50 CAB
EX INE
TE
ND T C
ER
PL
AT
A
E
S M-5
ER 0
IES
DA
C
TE3
RP
N
G
A
TE3
PM-9
/ PM
E3BB-BD/INCC “D” CAB
COMBINATION
FIRE/ACU
-9G
IN
S E I- V G
RI E
S
IL
I- E
S E 3, I L
RI
I
E 95 AN S O E3
R
X
T EL
BO EP
HO
X
NE
IL I-
E
S E 3, I L
R IE I 9
S
AN
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
X
5O R E3
21
Basic E3 Series In-Building Mass Notification Cabinet Configurations
E3 Series ACU “C” Size Cabinet used for Combination
3.1 E3 Series ACU “C” Size Cabinet used for Combination
Fire/MNS System (NGA Display) Ordering Information
The E3 Series ACU “C” Size Cabinet is used to house the components that support the E3 Series
Combined Fire/Mass Notification System. Figure 3.1.1 illustrates the E3 Series ACU “C” Size cabinet configuration. Table 3.1.1 lists the E3 Series ACU “C” Size cabinet ordering information.
IL
IL I I-M B
95
-M - E 3
BDA
E3
CT
E3
NG
A
RP
T -E
CA
BI
NE
T
C
3
P
PM M-9
-9 /
G
-
TE
LE
PH
ON
IN IEB
OX
AM
-5 0
VG
SE
R IE
S
CA
E X B IN E
TE
ND T C
ER
P
AM
S E -5 0
R IE
S
LA
TE
Figure 3.1.1 E3 Series ACU “C” Size Configuration
List Price
Qty Part Number
Model Number
Description
Note 1: X represents the required components.
Note 2: If you use the AM-50 Plate, you must install a separate battery box to house the system batteries.
Cabinet
E3BB-BC/INCC
E3-INCC-C PLATE
E3ID3-C
Modules
X
1100-0505
X
1100-0452
X
1100-0455
1100-0451
X
ILI-MB-E3
ILI95-MB-E3
X
PM-9
1100-1321
1100-1322
1100-1323
1100-1324
1100-1325
1100-1326
Optional Components
AM-50-Plate
1100-0456
AM-50-70
90521
90492
E3-TRIMKIT-C
DACT-E3
RPT-E3-UTP
FSL-E3
FML-E3
E3-BP
1100-0450
X
X
X
Dimensions:
30”H x 19 3/8”W x 4 1/2”D
Mounting Plate
3 Slots Door
Enclosure, Command Center Black, “C” Size
Command Center Mounting Plate, “C” Size
Inner Door, Command Center, 3 Slots “C” Size
NGA
MIC
ASM-16
INCC-TEL
System Sensor
Apollo Sensor
Power Supply
INI-VGC-FO
INI-VGC-UTP
INI-VGX-FO
INI-VGX-UTP
INI-VGE-FO
INI-VGE-UTP
NGA, Network Graphic Annunciator
INCC-MIC, Paging Microphone
Programmable Switch Module
Command Center Firefighter Telephone Module
Intelligent Loop Interface, Mother Board (max-1)
Intelligent Loop Interface, Mother Board (max-2)
9 Ampere Power Supply
Command Center Voice Gateway Fiber-Optic
Command Center Voice Gateway Twisted-Pair
Transponder Voice Gateway Fiber-Optic
Transponder Voice Gateway Twisted-Pair Wire
Classic Voice Gateway Fiber-Optic
Classic Voice Gateway Twisted-Pair Wire
AM-50 Extender Plate (See Note 2)
AM-50-25
70V Amp
Line Filter
Thumb Lock
Amplifier Extender Plate (Supports One AM-50)
AM-50 Watt Amplifier (max-1)
70V 50 Watt amplifier (max-1)
AC Line Filter Required with 70V Amplifier
Thumb Quarter Turn Latch
Trim Ring Kit
Digital Alarm Communication Transmitter
Network Repeater, Unshielded Twisted-Pair
Fiber Network Module, Single-Mode Fiber, 1 Channel
Fiber Network Module, Multi-Mode Fiber, 1 Channel
Double Size Inner Door Blank Plate (Pack of 1 Plate)
Single Size Inner Door Blank Plate (Pack of 3 Plates)
DACT
Networking Card
Fiber Networking
Fiber Networking
Inner Door Blank Plate
Inner Door Blank Plate
Table 3.1.1 E3 Series ACU “C” Size Cabinet for Combination Fire/MNS System Ordering Information
22
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
E3 Series ACU “D” Size Cabinet used for Combination Fire/MNS System (NGA Display) Ordering Information Basic E3 Series
3.2 E3 Series ACU “D” Size Cabinet used for Combination Fire/MNS
System (NGA Display) Ordering Information
The E3 Series ACU “D” Size Cabinet is used to house the components that support the E3 Series
Combined Fire/Mass Notification System. Figure 3.2.1 illustrates the E3 Series ACU “D” Size cabinet configuration. Table 3.2.1 lists the E3 Series ACU “C” Size cabinet ordering information.
DA
C
T-
N
G
A
E3
RP
T-
E3
PM9/ P
M
-9 G
IN
S E I- V G
RI E
S
IL
I- E
S E 3, I L
I
RI
E 95 AN S O E3
R
X
TE
BO LE P
HO
X
NE
IL I
-E
S E 3, I L
R IE I 9 5
AN S O R E3
X
Figure 3.2.1 E3 Series ACU “D” Size Cabinet Configuration
Qty Part Number
Model Number
Description
Note: X represents the required components.
Cabinet
E3BB-BD/INCC
E3-INCC-D PLATE
E3ID3-D
Modules
X
1100-0505
X
1100-0452
X
1100-0455
1100-0451
X
ILI-MB-E3
ILI-S-E3
ILI95-MB-E3
ILI95-S-E3
X
PM-9
1100-1321
1100-1322
1100-1323
1100-1324
1100-1325
1100-1326
Optional Components
1100-0456
AM-50-70
90521
90492
E3-TRIMKIT-C
DACT-E3
RPT-E3-UTP
FSL-E3
FML-E3
E3-BP
1100-0450
X
X
X
Dimensions:
41”H x 19 3/8”W x 4 1/2”D
Mounting Plate
3 Slots Door
Enclosure, Command Center Black, “D” Size
Command Center Mounting Plate, “D” Size
Inner Door, Command Center, 3 Slots “D” Size
NGA
MIC
ASM-16
INCC-TEL
Loop Interface
Loop Interface
Loop Interface
Loop Interface
Power Supply
INI-VGC-FO
INI-VGC-UTP
INI-VGX-FO
INI-VGX-UTP
INI-VGE-FO
INI-VGE-UTP
NGA, Network Graphic Annunciator
INCC-MIC, Paging Microphone
Programmable Switch Module
Command Center Firefighter Telephone Module
Intelligent Loop Interface, Mother Board
Intelligent Loop Interface, Supplemental
Intelligent Loop Interface, Mother Board XP95
Intelligent Loop Interface, Supplemental XP95
9 Ampere Power Supply
Command Center Voice Gateway Fiber-Optic
Command Center Voice Gateway Twisted-Pair
Transponder Voice Gateway Fiber-Optic
Transponder Voice Gateway Twisted-Pair Wire
Classic Voice Gateway Fiber-Optic
Classic Voice Gateway Twisted-Pair Wire
AM-50-25
70V Amp
Line Filter
Thumb Lock
AM-50 Watt Amplifier (max-1)
70V 50 Watt amplifier (max-1)
AC Line Filter Required with 70V Amplifier
Thumb Quarter Turn Latch
Trim Ring Kit
Digital Alarm Communication Transmitter
Network Repeater Twisted-Pair Wire
Fiber Network Module, Single-Mode Fiber, 1 Channel
Fiber Network Module, Multi-Mode Fiber, 1 Channel
Double Size Inner Door Blank Plate (Pack of 1 Plate)
Single Size Inner Door Blank Plate (Pack of 3 Plates)
DACT
Networking Card
Fiber Networking
Fiber Networking
Inner Door Blank Plate
Inner Door Blank Plate
List Price
Table 3.2.1 E3 Series ACU “D” Size Cabinet Combination Fire/MNS System
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
23
Basic E3 Series In-Building Mass Notification LOC Configurations
Section 4: Basic E3 Series In-Building Mass
Notification LOC Configurations
IN I
LOC
-V
G
SE
RI
ES
N GA
LOC-TEL
24
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
E3 Series LOC Local Operating Console Ordering Information
Basic E3 Series In-Building Mass Notification LOC
4.1 E3 Series LOC Local Operating Console Ordering
Information
The E3 Series LOC Local Operating Console is used to house the components that support the
remote audio modules of the E3 Series Combined Fire/Mass Notification System. Figure 4.1.1
illustrates the E3 Series LOC Local Operating Console cabinet configuration. Table 4.1.1 lists the
E3 Series LOC Local Operating Console ordering information.
IN I
-V
G
SE
RI
ES
N GA
Figure 4.1.1 E3 Series LOC Local Operating Console
Qty
Part Number
Model Number
Description
List
Price
Note: X represents the required components.
Cabinet
Dimensions:
X
E3BB-BAA
19 1/4”W x 10”H x 4 1/4” D
Enclosure, Black, “AA” Size Cabinet
X
E3ID3-A
3 Slots Door
Inner Door, 3 Slots
Modules
X
1100-1321
Voice Gateway
INI-VGC, Voice Gateway
X
1100-0452
MIC
INCC-MIC, Paging Microphone
X
1100-0455
ASM-16
Programmable Switch Module
X
1100-04-5
NGA
NGA, Network Graphic Annunciator
LOC Lock-out
Addressable Output Supervised Relay
Optional Components
AOM-2SF
90492
Thumb Quarter Turn Latch
E3-TRIMKIT-A
Trim Ring Kit
Table 4.1.1 E3 Series LOC Local Operating Console Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
25
Basic E3 Series In-Building Mass Notification LOC Configurations
E3 Series LOC-TEL Local Operating Console Ordering
4.2 E3 Series LOC-TEL Local Operating Console Ordering
Information
The E3 Series LOC-TEL Local Operating Console is used to house the components that support the
remote audio modules of the E3 Series Combined Fire/Mass Notification System. Figure 4.2.1
illustrates the E3 Series LOC Local Operating Console configuration. Table 4.2.1 lists the E3
Series LOC Local Operating Console ordering information
Figure 4.2.1 E3 Series LOC-TEL Local Operating Console
Qty
Part Number
Model Number
Description
List
Price
Note: X represents the required components.
Cabinet
X
E3BB-BAA
X
E3ID2-TA
X
90510
Modules
X
1100-0451
X
1100-0455
X
AOM-TELF
X
1N4006
Optional Components
90492
E3-TRIMKIT-A
Dimensions:
19 1/4“ x 10”H x 4 1 /2”D
2 Slots Door
AOM-TEL PLATE
Enclosure, Black, “AA” Size Cabinet
Inner Door, 2 Slots for INCC-Tel
KIT, AOM-TEL Plate, E3
INCC-TEL
ASM-16
Monitor Module
Blocking Diode
Firefighter Telephone Module
Programmable Switch Module
Telephone Monitor Module
Thumb Lock
Thumb Quarter Turn Latch
Trim Ring Kit
Table 4.2.1 E3 Series LOC-TEL Local Operating Console Ordering Information
26
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
Basic E3 Series Audio Transponder Cabinet Configurations
Section 5: Basic E3 Series Audio Transponder Cabinet
Configurations
INXCAB-B
CA
BI
NE
TB
INI
-VG
X
AM
SE -50
RI
ES
INX-Transponder CAB-B
AM
SE -50
RI
ES
BA
TT
ER
IES
DA
CT
-E3
RP
T-E
3
IN
SE I-VG
RIE
S
INX-Transponder CAB-C
AM
SE -50
RIE
S
AM
SE -50
RIE
S
INX D CABINET,
E3-INX-D PLATE
DA
CT
-E3
RP
T-E
3
BA
TT
ER
IES
IL
ILI9 I-MB-E
5-M 3/
B-E
3
PM
-9/P
M-9
G
INISE VG
RIE
S
INX-Transponder CAB-D
AM
SE -50
RIE
S
AM
SE -50
RIE
S
BA
TT
ER
IES
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
27
Basic E3 Series Audio Transponder Cabinet Configurations
E3 Series INX CAB-B Cabinet Ordering Information
5.1 E3 Series INX CAB-B Cabinet Ordering Information
The E3 Series INX CAB-B cabinet is used to house the components that support the E3 Series
Voice Evacuation and the Combined Fire/Mass Notification Systems. Figure 5.1.1 illustrates the E3
Series INX CAB-B cabinet configuration. Table 5.1.1 lists the E3 Series INX CAB-B cabinet
ordering information.
IN X C A B -B
CA
IN
I-V
BI
NE
TB
GX
AM
SE -5 0
R IE
S
A
S E M -5 0
RI
ES
BA
TT
ER
IE S
Figure 5.1.1 E3 Series INX CAB-B Cabinet Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents the required components.
X
Cabinet
Dimensions:
INX CAB-B
19 3/8”W x 19 3/8”H x 4 1/2”D
1100-0460
Cabinet
Enclosure, INX CAB-B, “B” Size
Modules
X
PM-9
Power Supply
9 Ampere Power Supply
X
1100-1323
INI-VGX
Voice Gateway
NOTE: Only one type of 50 Watt amplifier may be connected to the INI-VGX (25V or 70V).
2
1100-0456
AM-50-25
25 Volt 50 Watt Amplifier
AM-50-70
AM-50-70
70 Volt 50 Watt Amplifier
AC Line Filter
AC Line Filter, Required with 70V Amplifier
90518
7 A/H Seismic Kit
E3 CAB-B 7 A/H Seismic Battery Bracket Kit
90519
12 A/H Seismic Kit
E3 CAB-B 12 A/H Seismic Battery Bracket Kit
18 A/H Seismic Kit
E3 CAB-B 18 A/H Seismic Battery Bracket Kit
Batteries
18 A/H
90521
Optional Components
E3-TRIMKIT-B
90520
Trim Ring Kit
Table 5.1.1 E3 Series INX CAB-B Cabinet Ordering Information
28
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
E3 Series INX CAB-C Cabinet Ordering Information
Basic E3 Series Audio Transponder Cabinet Configurations
5.2 E3 Series INX CAB-C Cabinet Ordering Information
The E3 Series INX CAB-C cabinet is used to house the components that support the E3 Series
Voice Evacuation and the Combined Fire/Mass Notification Systems. Figure 5.2.1 illustrates the E3
Series INX CAB-C cabinet configuration. Table 5.1.1 lists the E3 Series INX CAB-C cabinet
ordering information.
DA
CT
-E
3
RP
T-E
3
IN
SE I-VG
RI
ES
AM
SE -50
RIE
S
AM
SE -50
RIE
S
BA
TT
ER
IES
Figure 5.2.1 E3 Series INX CAB-C Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents the required components.
X
X
X
X
X
Cabinet
INX CAB-C
E3BB-BC/INX
E3-INX-C Plate
90375
Modules
PM-9
1100-1323
1100-0456
Dimensions:
19 3/8”W x 30”H x 4 1/2”D
INX, Cabinet
INX-C Plate
PM-9 Adapter Plate
Enclosure, Transponder, Black, “C” Size
INX-C Mounting Plate
PM-9 Adapter Plate Kit, Hardware, E3-INX
Power Supply
INI-VGX
AM-50-25
9 Ampere Power Supply
Voice Gateway
25 Volts 50 Watt Amplifier
NOTE: Only one type of 50 Watt amplifier may be connected to the INI-VGX (25V or 70V).
AM-50-70
90521
2
Batteries
Optional Components
ILI-MB-E3
ILI95-MB-E3
DACT-E3
RPT-E3-UTP
FLS-E3
FML-E3
E3-TRIMKIT-C
90518
90519
90520
AM-50-70
AC Line Filter
70 Volt 50 Watt Amplifier
AC Line Filter, Required with 70V Amplifier
2-18 AH
SLC
SLC
DACT
Networking Card
Fiber Networking
Fiber Networking
Intelligent Loop Interface, Mother Board
XP95 Intelligent Loop Interface, Mother Board
Digital Alarm Communication Transmitter
Network Repeater, Unshielded Twisted-Pair
Fiber Network Module, Single-Mode Fiber, 1 Channel
Fiber Network Module, Multi-Mode Fiber, 1 Channel
Trim Ring Kit
E3 CAB-C 7 A/H Seismic Battery Kit
E3 CAB-C 12 A/H Seismic Battery Kit
E3 CAB-C 18 A/H Seismic Battery Kit
7 A/H Seismic Kit
12 A/H Seismic Kit
18 A/H Seismic Kit
Table 5.2.1 E3 Series INX CAB-C Cabinet Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
29
Basic E3 Series Audio Transponder Cabinet Configurations
E3 Series INX CAB-D Cabinet Ordering Information
5.3 E3 Series INX CAB-D Cabinet Ordering Information
The E3 Series INX CAB-D cabinet is used to house the components that support the E3 Series
Voice Evacuation and the Combined Fire/Mass Notification Systems. Figure 5.3.1 illustrates the E3
Series INX CAB-D cabinet configuration. Table 5.3.1 lists the E3 Series INX CAB-D cabinet
ordering information.
INX D CABINET,
E3-INX-D PLATE
DA
C
T-E
3
RP
T
-E3
IL
ILI9 I-MB5-M E3/
B-E
3
PM
-9/P
M-9
G
INI
S E - VG
RIE
S
AM
SE -50
RIE
S
AM
SE -50
RIE
S
BA
TT
E
RIE
S
Figure 5.3.1 E3 Series INX CAB-D Cabinet Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents the required components.
X
X
X
X
Cabinet
INX CAB-D
E3BB-BD/INX
E3-INX-D Plate
Modules
PM-9
1100-1323
1100-0456
Dimensions:
19 3/8”W x 41”H x 4 1/2”D
INX, Cabinet
INX-D Plate
Enclosure, Transponder, Black, “D” Size
INX-D Mounting Plate
Power Supply
INI-VGX
AM-50-25
9 Ampere Power Supply
Transponder Voice Gateway
25 Volts 50 Watt Amplifier
NOTE: Only one type of 50 Watt amplifier may be connected to the INI-VGX (25V or 70V).
AM-50-70
90521
2
Batteries
Optional Components
ILI-MB-E3
ILI95-MB-E3
DACT-E3
RPT-E3-UTP
FSL-E3
FML-E3
E3-TRIMKIT-D
90518
90519
90520
AM-50-70
AC Line Filter
70 Volt 50 Watt Amplifier
AC Line Filter, Required with 70V Amplifier
2-18 AH
SLC Card
XP95 SLC
DACT
Networking Card
Fiber Networking
Fiber Networking
Intelligent Loop Interface, Mother Board
XP95 Intelligent Loop Interface, Mother Board
Digital Alarm Communication Transmitter
Network Repeater, Unshielded Twisted-Pair
Fiber Network Module, Sing-Mode Fiber, 1 Channel
Fiber Network Module, Multi-Mode Fiber, 1 Channel
Trim Ring Kit
E3 CAB-D 7 A/H Seismic Battery Kit
E3 CAB-D 12 A/H Seismic Battery Kit
E3 CAB-D 18 A/H Seismic Battery Kit
7 A/H Seismic Kit
12 A/H Seismic Kit
18 A/H Seismic Kit
Table 5.3.1 E3 Series INX CAB -D Cabinet Ordering Information
30
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
Section 6: E3 Series Classic Bulk Audio Cabinet
Configurations
S B B -C 4
A
C
T1
A A - 1 0 0/ A A 1 2 0
R-125
R-18
A A - 1 0 0/ A A 1 2 0
R- 125
R-18
Bulk Audio SBB-C4
A A - 1 0 0/ A A 1 2 0
R-18
R- 125
B a tte ry
C h a rg e r
F C I-L L B
BATTERY BOX
S B B -D 4
A
C
T1
A A - 1 0 0/ A A 1 2 0
R-125
R -18
A A - 1 0 0/ A A 1 2 0
R-125
R -18
A A - 1 0 0/ A A 1 2 0
R-18
R-125
Bulk Audio SBB-D4
A A- 1 0 0/ A A 1 2 0
R-18
R-125
B a tte ry
C h arge r
F C I-L L B
BATTERY BO X
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
31
E3 Series Classic Bulk Audio Cabinet Configurations
E3 Series Classic, SBB-C4 Cabinet Ordering Information
6.1 E3 Series Classic, SBB-C4 Cabinet Ordering Information
The E3 Series Classic, SBB-C4 Cabinet houses the components that support the bulk audio amplifiers required for the E3 Series Fire and Voice Evacuation Systems. Figure 6.1.1 illustrates the E3
Series Classic SBB-C4 cabinet configuration. Table 6.1.1 lists the E3 Series Classic SBB-C4 cabinet ordering information.
S B B -C 4
A
C
T1
A A - 1 0 0/ A A 1 2 0
R -125
R-18
A A - 1 0 0/ A A 1 2 0
R-125
R -18
A A - 1 0 0/ A A 1 2 0
R -18
R-125
B a tte ry
C h a rg e r
F C I-L L B
BATTERY BOX
Figure 6.1.1 E3 Series Classic, SBB-C4 Cabinet Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents the required components.
X
X
Cabinet
Dimensions:
SBB-C4
24 W X 37 1/8 H X 5 1/8 D
Backbox, Accepts 3 Chassis, Black
FCI-DR-C4B
Blank Door
Blank Door, Lock & Keys, for 3 Chassis Backbox
Modules
AA-120
Bulk Audio Amplifier
120 W Amplifier 25 V RMS
AA-100
Bulk Audio Amplifier
100 W Amplifier 70.7 VRMS
X
ACT-1
Audio Coupling Transformer (one required)
X
FCI-CHG-120
Battery Charger, 25-120 A/H Gel Cell
X
FCI-LBB
Large Battery Box
Optional Components
MCH-6
MCH-6 6-Unit Mounting Chassis
MMO-6SF
Multi-Module Output, Relay
Table 6.1.1 E3 Series Classic SBB-C4 Cabinet Ordering Information
32
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
E3 Series Classic SBB-D4 Ordering Information
E3 Series Classic Bulk Audio Cabinet Configurations
6.2 E3 Series Classic SBB-D4 Ordering Information
The E3 Series Classic, SBB-D4 Cabinet houses the components that support the bulk audio amplifiers required for the E3 Series Fire and Voice Evacuation Systems. Figure 6.2.1 illustrates the E3
Series Classic cabinet configuration. Table 6.2.1 lists the E3 Series Classic Bulk Audio cabinet
ordering information.
S B B -D 4
A
C
T1
A A - 1 0 0/ A A 1 2 0
R - 125
R -18
A A - 1 0 0/ A A 1 2 0
R- 125
R -18
A A - 1 0 0/ A A 1 2 0
R -18
R - 125
A A - 1 0 0/ A A 1 2 0
R-18
R - 125
B a tte ry
C h a rg e r
F C I-L L B
BATTERY BOX
Figure 6.2.1 E3 Series Classic, SBB-D4 Cabinet Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents the required components.
X
X
Cabinet
Dimensions:
SBB-D4
24” W x 45 7/8” H x 5 1/8” D
Cabinet Backbox, Accepts 4 Chassis, Black
FCI-DR-D4B
Blank Door
Blank Door, Lock & Keys, for 4 Chassis Backbox
Modules
AA-120
Bulk Audio Amplifier
120 W Amplifier 25 V RMS
AA-100
Bulk Audio Amplifier
100 W Amplifier 70.7 VRMS
X
ACT-1
Audio Coupling Transformer (one required)
X
FCI-CHG-120
Battery Charger, 25-120 A/H Gel Cell
X
FCI-LBB
Large Battery Box
Optional Components
MCH-6
MCH-6 6-Unit Mounting Chassis
MMO-6SF
Multi-Module Output, Relay
Table 6.2.1 E3 Series Classic SBB-D4 Cabinet Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
33
Section 7: Retrofit Kit Cabinets
Retrofit Kit Cabinets
DA
CT
-E
3
RP
T-E
3
LC
D-E
3
POW
ER
FAUL
T
AC
POW
ER
ON
ALARM
ACKNOWL
EDGE
IF600 Retrofit
ME
NU
GRO
UND
FAUL
T
TROUBLE
ACKNOWL
EDGE
BACKSP
ACE/
EDIT
OU
SYST
EM
TRO
UBLE
ALAR
M
SIGNAL
SILENCE
SUPERVI
SORY
SYST
EM
SILEN
CED
SYSTEM
RESET/
LAMP TEST
PM
-9/P
M9G
OK/
ENTER
60
TE 0XL
R D
OO
R
60
0X
L R
ET
R
IN
NE OF
IT
R
D
DO
LC
O R IS P L
D
-E
6 00
600XL Retrofit
XL
AS
RE
M -1
TR
3
600
IL I
DA
AY
OF
IT 3
-B
AY
AS
IN N
ER
DO
OR
72
00
CA
R
B
IN N E T R IN E
T B
ER OF
,
D O IT
O
A R
SM
-1 6
60
72
AD 00 C
AB
SU APT
IN E
E
BT
AS R P
SE LA B,
M B TE
DA
LY
CT
-E
3
RP
T -E
PM
P M -9 /
-9 G
FCI 7200 “B” Retrofit
IL I
72
00
R
C
O U ETR AB
-C
TE
O
R D F IT
OO
R
LC
D-
E3
AS
-S -
0X
S -E
3 /I L
L B
A
BO
I9 5
- -E 3
-E 3
RP
I9 5
CK
SE
T -E
3
- S -E
3
PL
AT
X
RI
ES
E
72
00
C
BA AB
C K IN E
BO T B
,
X
E3
72
0
BA 0 CA
CK
B
B O -C
X
CT
-E
3
RP
T
FCI 7200 “C”Retrofit
34
CK
-E 3
- / IL
CT
3
M16
DA
PM
72
00
CA
R
IN N E T R B IN
ET
OF
ER
D O IT
OR
BA
IL I-
M -1
6
AD
FR
F
FO
AS
M -1
R B RON ONT
6
T
P
AT
TE CO V LATE
R IE
E
S ( R
12
A /H
)
00
CA
R
O U E T R B IN E
T B
TE
O
R D F IT
,
OO
R
XL
PM
P M -9 /
-9 G
6
DE
72
IF6
00
BA -RET
CK RO
BO FIT
X
ILIMB
-E
3/IL
I95
-M
BE3
-E 3
-9 /
PM
IL I9
IL
5 -S I-S E3
/
OR E3 S
A N E R IE
X
IL I
IL I
-S
-S
-E
3/
OR E3 S
AN ERI
X
IL I
-9 G
S
95
ES
IL I
-S
-S
-E
3/
OR E3 S
AN ERI
ES
X
95
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
IF600-Retrofit Backbox Ordering Information
Retrofit Kit Cabinets
7.1 IF600-Retrofit Backbox Ordering Information
The IF600-Retrofit backbox is used to house the components that support the E3 Series Fire Evacuation System. Figure 7.1.1 illustrates the IF600-Retrofit backbox configuration. Table 7.1.1 lists
the IF600-Retrofit backboxordering information.
DA
CT
-E3
LC
DE3
POW
ER
FAUL
T
AC
POW
ER
ON
ALARM
ACKNOWL
EDGE
ME
NU
GRO
UND
FAUL
T
TROUBLE
ACKNOWL
EDGE
SYST
EM
TRO
UBLE
ALAR
M
SIGNAL
SILENCE
BACKSP
ACE/
EDIT
SUPERVI
SORY
RP
T-E
3
SYST
EM
SILEN
CED
SYSTEM
RESET/
LAMP TEST
ILI
-M
BE3
/IL
I95
-M
BE3
IF6
00
BA -RET
CK RO
BO FIT
X
PM
-9/
PM
-9G
OK/
ENTER
Figure 7.1.1 IF600 Retrofit Backbox Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents required components.
X
Cabinet
Dimensions:
IF600-RETROFIT
20 1/8”H x 14 1/8”W x 4 1/2”D
E3BB-RBSLIM Door, Red, Back Plate
Modules
ILI-MB-E3
System Sensor
Intelligent Loop Interface, Mother Board (max-1)
ILI-S-E3
System Sensor
Intelligent Loop Interface, Supplemental (max-1)
X
ILI95-MB-E3
Apollo Sensor
Intelligent Loop Interface, Mother Board (max-1)
X
ILI95-S-E3
Apollo Sensor
Intelligent Loop Interface, Supplemental (max-1)
X
PM-9
Power Supply
9 Ampere Power Supply
X
LCD-E3
Display
LCD Keypad Display
LCD-SLP
Display
LCD Touchscreen Display
DACT-E3
DACT
Digital Alarm Communiocation Transmitter
RPT-E3-UTP
Repeater
Network Repeater, Unshielded Twisted-Pair
RPT-E3-FO
Repeater
Network Repeater, Fiber-Optic
75687
Cable
75687-A Special Order Cable
2
Batteries
Optional Components
Table 7.1.1 IF600 Retrofit Backbox Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
35
Retrofit Kit Cabinets
600XL Retrofit Backbox Ordering Information
7.2 600XL Retrofit Backbox Ordering Information
The 600XL Retrofit backbox is used to house the components that supports the E3 Series Fire
Evacuation System. Figure 7.2.1 illustrates the 600XL Retrofit backbox configuration. Table 7.2.1
lists the 600XL Retrofit backbox ordering information.
OU
60
TE 0X L
R D
OO
R
60
0X
L R
E
IN T R O
NE
R F IT D
D
IS
LC O O
DR PL
E3
600
XL
AS
RE
M -1
TR
XL
IL I
DA
AY
BA
CK
-E
- 3 / IL
CT
OF
IT 3
-B
AY
IN N
ER
DO
AS
OR
M -1
6
AD
FR
F
FO
AS
M -1
R B RON ONT
6
T
P
AT
TE C O V LA TE
R IE
ER
S(
12
A /H
)
I L I-
-E 3
60
0X
S -E
BO
I9 5
- -E 3
RP
PM
P M -9 /
-9 G
6
DE
600
3 /IL
L B
AC
I9 5
T -E
-S -
X
SE
R IE
S
3
E3
K P
L
AT
E
Figure 7.2.1 600XL Retrofit Backbox Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents required components.
Cabinet
Dimensions:
X
600XL RETROFIT
Gamewell IF 602XL, IF610XL, Includes Inner Door for the LCD-E3 and a Plate for
IF632 Cabinet Retrofit Kit for
three ASM-16s.
E3 Series Upgrade
Also includes a Dead Front Cover, Cabinet
Mounting Plate for an E3 C-Size Plate.
X
E3-ILI-CPLATE
Used for FACP
Intelligent Loop Module Mounting Plate
Modules
X
ILI95-MB-E3
Apollo Sensor
Intelligent Loop Interface, Mother Board (max-1)
ILI95-S-E3
Apollo Sensor
Intelligent Loop Interface, Supplemental (max-1)
LCD-E3
Display
LCD Keypad Display
LCD-SLP
Display
LCD Touchscreen Display
X
PM-9
E3 Series Power Supply
X
2 Batteries
X
9 Ampere Power Supply
Maximum 18 AH Capacity
Optional Components
1100-0450
Inner Door Filler Plate
Single Size Inner Door Blank Plate (pack of 3 plates)
1100-0455
ASM-16
ASM-16 Programmable Switch Module
DACT-E3
DACT
Digital Alarm Communiocation Transmitter
RPT-E3-UTP
Networking Card
Network Repeater, Unshielded Twisted-Pair
FSL-E3
Fiber Networking
Fiber Network Module, Single-Mode Fiber, 1
Channel
FML-E3
Fiber Networking
Fiber Network Module, Multi-Mode Fiber, 1 Channel
RAN-7100
Remote Serial Annunciator
Installs on GWRAN2-BB
Table 7.2.1 600XL Retrofit Backbox Ordering Information
36
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
7200 Retrofit Kit “B” Size Backbox Ordering Information
Retrofit Kit Cabinets
7.3 7200 Retrofit Kit “B” Size Backbox Ordering Information
The 7200 Retrofit Kit “B” Size backbox is used to house the components that upgrade the 7200
System to the E3 Series Fire Evacuation System. Figure 7.3.1 illustrates the 7200 Retrofit Kit “B”
Size backbox configuration. Table 7.3.1 lists the 7200 Retrofit Kit “B” Size backbox ordering
information.
72
72
00
C
RE ABI
OU
TR N E
T
TE
O
R D F IT B ,
OO
R
00
C
RE ABI
IN N T R N E
ER OF T B
,
D O IT
OR
A
SM
-1 6
72
AD 00 C
A
S U A P T B IN
ER
BET
AS
SE PLA B,
M B TE
DA
LY
CT
-E
3
RP
T -E
PM
P M -9 /
-9 G
IL I
-S -
72
00
C
BA AB
C K IN E
BO T B
,
X
3
E3
Figure 7.3.1 7200 Retrofit Kit “B” Size Backbox Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents the required components.
Cabinet
Dimensions:
X
7200-B-RETROFIT FCI 7200 B Size Backbox
Retrofit Kit for E3 Series
upgrade
Includes Outer Door, Inner Door for LCD-E3 &
ASM-16, Cabinet Mounting Plate for E3 C-Size
Plate
X
E3-ILI-CPLATE
Used for FACP
Intelligent Loop Module Mounting Plate
ILI-MB-E3
System Sensor
Intelligent Loop Interface, Mother Board (max-1)
ILI-S-E3
System Sensor
Intelligent Loop Interface, Supplemental (max-1)
LCD-E3
Display
LCD Keypad Display
LCD-SLP
Display
LCD Touchscreen Display
X
PM-9
Power Supply
9 Ampere Power Supply
X
2 Batteries
Modules
X
X
Maxium 18 AH Capacity
Optional Components
1100-0455
ASM-16
ASM-16 Programmable Switch Module
DACT-E3
DACT
Digital Alarm Communication Transmitter
RPT-E3-UTP
Repeater
Network Repeater, Unshielded Twisted-Pair
FSL-E3
Fiber Networking
Fiber Network Module, Single-Mode Fiber,
1 Channel
FML-E3
Fiber Networking
Fiber Network Module, Multi-Mode Fiber, 1 Channel
1100-0450
Inner Door Blank Plate
Single Size Inner Door Blank Plate
(Pack of 3 Plates)
Table 7.3.1 7200 Retrofit Kit “B” Size Backbox Ordering Information
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
37
Retrofit Kit Cabinets
7200 Retrofit Kit “C” Size Backbox Ordering Information
7.4 7200 Retrofit Kit “C” Size Backbox Ordering Information
The 7200 Retrofit Kit “C” Size backbox is used to house the components that upgrade the 7200
System to the E3 Series Fire Evacuation System. Figure 7.4.1 illustrates the 7200 Retrofit Kit “C”
Size backbox configuration. Table 7.4.1 lists the 7200 Retrofit Kit “C” Size backbox ordering
information.
72
0
RE 0 CA
OU
TR
BC
TE
O
R D F IT
OO
R
LC
D-
E3
AS
M-
72
0
BA 0 CA
CK
B
B O -C
X
16
DA
CT
-E 3
RP
T -E
PM
IL I9
IL I9
00
CA
R
IN N E T R B IN
ER O FI ET
DO T
OR
IL I9
-9 /P
IL
5 -S I- S E3
-E
OR 3 S /
A N E R IE
X
M-
9G
S
IL
5 -S I- S
-E
OR
72
3
-E
3 S 3/
A N E R IE
X
S
IL
5 - S I- S -E
-E
3
OR 3 S /
A N E R IE
X
S
Figure 7.4.1 7200 Retrofit Kit “C” Size Backbox Configuration
Qty
Part Number
Model Number
Description
List
Price
Note: X represents the required components.
Cabinet
Dimensions:
X
7200-C-RETROFIT FCI 7200-C-Size Backbox
Retrofit Kit for E3 Series
upgrade
Includes Outer Door,
Inner Door for LCD-E3 & ASM-16,
Cabinet Mounting Plate for E3 D-Size Plate
X
E3-INCC-DPLATE
Used for FACP
Intelligent Loop Module Mounting Plate
System Sensor
Intelligent Loop Interface, Mother Board (max-1)
Modules
X
ILI-MB-E3
ILI-S-E3
System Sensor
Intelligent Loop Interface, Supplemental (max-1)
X
LCD-E3
Display
LCD Keypad Display
LCD-SLP
Display
LCD Touchscreen Display
X
PM-9
Power Supply
9 Ampere Power Supply
X
2 Batteries
Maximum 18 AH Capacity
Optional Components
1100-0455
ASM-16
ASM-16 Programmable Switch Module
DACT-E3
DACT
Digital Alarm Communication Transmitter
1100-0450
Inner Door Blank Plate
Single Size Inner Door Blank Plate (Pack of 3 Plates)
RPT-E3-UTP
Networking Card
Network Repeater, Unshielded Twisted-Pair
FSL-E3
Fiber Networking
Fiber Network Module, Single-Mode Fiber, 1
Channel
FML-E3
Fiber Networking
Fiber Network Module, Multi-Mode Fiber, 1
Channel
Table 7.4.1 7200 Retrofit Kit “C” Size Backbox Ordering Information
38
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
Manufacturer Warranties and Limitation of Liability
Manufacturer Warranties. Subject to the limitations set forth herein,
Manufacturer warrants that the Products manufactured by it in its
Northford, Connecticut facility and sold by it to its authorized
Distributors shall be free, under normal use and service, from defects
in material and workmanship for a period of thirty six months (36)
months from the date of manufacture (effective Jan. 1, 2009). The
Products manufactured and sold by Manufacturer are date stamped at
the time of production. Manufacturer does not warrant Products that
are not manufactured by it in its Northford, Connecticut facility but
assigns to its Distributor, to the extent possible, any warranty offered
by the manufacturer of such product. This warranty shall be void if a
Product is altered, serviced or repaired by anyone other than
Manufacturer or its authorized Distributors. This warranty shall also
be void if there is a failure to maintain the Products and the systems in
which they operate in proper working conditions.
MANUFACTURER MAKES NO FURTHER WARRANTIES, AND
DISCLAIMS ANY AND ALL OTHER WARRANTIES, EITHER
EXPRESSED OR IMPLIED, WITH RESPECT TO THE PRODUCTS,
TRADEMARKS, PROGRAMS AND SERVICES RENDERED BY
MANUFACTURER
INCLUDING
WITHOUT
LIMITATION,
INFRINGEMENT, TITLE, MERCHANTABILITY, OR FITNESS FOR
ANY PARTICULAR PURPOSE. MANUFACTURER SHALL NOT BE
LIABLE FOR ANY PERSONAL INJURY OR DEATH WHICH MAY
ARISE IN THE COURSE OF, OR AS A RESULT OF, PERSONAL,
COMMERCIAL OR INDUSTRIAL USES OF ITS PRODUCTS.
This document constitutes the only warranty made by Manufacturer
with respect to its products and replaces all previous warranties and is
the only warranty made by Manufacturer. No increase or alteration,
written or verbal, of the obligation of this warranty is authorized.
Manufacturer does not represent that its products will prevent any loss
by fire or otherwise.
Warranty Claims.
Manufacturer shall replace or repair, at
Manufacturer's discretion, each part returned by its authorized
Distributor and acknowledged by Manufacturer to be defective,
provided that such part shall have been returned to Manufacturer with
all charges prepaid and the authorized Distributor has completed
Manufacturer's Return Material Authorization form. The replacement
part shall come from Manufacturer's stock and may be new or
refurbished. THE FOREGOING IS DISTRIBUTOR'S SOLE AND
EXCLUSIVE REMEDY IN THE EVENT OF A WARRANTY CLAIM.
Warn-HL-08-2009.fm
E3 Series and S3 Series Building Blocks Reference Guide — P/N 9021-60764:A2 03/23/2016
39
Gamewell-FCI
12 Clintonville Road
Northford, CT 06472-1610 USA
203-484-7161
fax 203-484-7118
www.gamewell-fci.com

Similar documents

Our Catalog! - Party Productions and Events

Our Catalog! - Party Productions and Events ‘Happy St Patrick’s Day!” SLN01110130 Snack Plt 8ct “O’Drinky’s...” SDR01140099 DPlate 8ct. “McGoggle’s, Where Everyone Gets Better Looking As The Night Goes On!” SDN01110108 NEW

More information