Op tional fea tures - all mod els (con tin ued)

Transcription

Op tional fea tures - all mod els (con tin ued)
Technical Data
Manual
Challenger
Plus
Liebert
Keeping Business in Business
LPN: SLE CP TDM E.1
HPN: 272030 (17/6/99)
Table of Contents
Nomenclature
1
Introduction
2
Standard features - all models
6
Standard features - DX models
9
Standard features - chilled water models
12
Optional features - all models
13
Air cooled data
18
Water cooled data
20
Air cooled dual source data
22
Water cooled dual source data
24
Freecooling data
26
Chilled water cooled data
28
Condenser matching tables
30
Chilled water data - all models
31
Electrical data - all models
32
Sound data - all models
37
Technical data - optional components
39
Dimensional data - all models
47
Challenger Plus - Technical Data Manual
Nomenclature
System nomenclature
CP20 A D
Air Distribution:
D = Downflow
U = Upflow
System type:
A = Air Cooled
W = Water/ Glycol Cooled
F = Freecooling
D = Dual Source Air Cooled
H = Dual Source Water Cooled
C = Chilled Water Cooled
Model Number:
Nominal capacity in kW at 240C, 50% RH
Liebert Challenger Plus Unit
The range of models is as follows:
Air Cooled
Single Circuit
CP20A U/D
CP24A U/D
CP28A U/D
CP34A U/D
Dual Circuit
CP26A U/D
CP32A U/D
CP42A U/D
CP46A U/D
Single Circuit
CP20W U/D
CP24W U/D
CP28W U/D
CP34W U/D
Dual Circuit
CP26W U/D
CP32W U/D
CP42W U/D
CP46W U/D
Single Circuit
CP20F U/D
CP24F U/D
CP28F U/D
CP34F U/D
Dual Circuit
CP26F U/D
CP32F U/D
CP42F U/D
CP46F U/D
Single Circuit
CP20D U/D
CP24D U/D
CP28D U/D
CP34D U/D
Dual Circuit
CP26D U/D
CP32D U/D
CP42D U/D
CP46D U/D
Single Circuit
CP20H U/D
CP24H U/D
CP28H U/D
CP34H U/D
Dual Circuit
CP26H U/D
CP32H U/D
CP42H U/D
CP46H U/D
CP25C U/D
CP35C U/D
CP50C U/D
CP60C U/D
CP40A U/D
Water /Glycol Cooled
CP40W U/D
Freecooling
CP40F U/D
Dual Source Air Cooled
CP40D U/D
Dual Source Water Cooled
CP40H U/D
Chilled Water Cooled
Single Circuit
SLE CP TDM E.1 (06/99)
CP70C U/D
1
Challenger Plus - Technical Data Manual
Introduction
Precision environmental control may be defined as the
si mul ta ne ous con trol of air tem pera ture, hu mid ity,
distribution and cleanliness on a continual, around-the-clock
basis.
Conventional building or ‘comfort’ systems, as they are
called, are not designed for this 24-hour, year-round usage;
they lack the ability to provide the precision and reliability or
‘close control‘ that is so critical to many applications.
The Lie bert Chal lenger Plus is a new se ries of air
conditioners designed by Liebert to meet the requirements of
data processing centers and other small and medium sized
critical areas.
The Challenger Plus series comprises both direct expansion
units and chilled water units. Cooling capacities range from
20 to 70 kW, for a total of 54 models. Direct expansion units
are equipped with compliant scroll compressors. The design
of the scroll compressor, ensures a constant refrigerant
pressure, thus improving reliability, energy consumption and
sound emission.
Liebert technology and energy
efficiency
Lie bert has be c o m e a world leader in pre ci sion
environmental control systems by providing maximum
energy efficiency without compromising precision and
reliability.
Liebert takes a no-compromise approach to environmental
con trol sys tem de sign. All en hance ments to en ergy
efficiency are designed to reduce operating time of key
components. This is accomplished by taking advantage of
alternate sources of cooling when available or, by reducing
compressor work load when the heat load in the critical space
is lower.
Manufacture
All units are built in ac cor dance Euro pean di rec tives
98/37/CE (89/392/CEE; 91/368/CEE; 93/68/CEE),
89/336/CEE; 73/23/CEE. The Liebert Air Conditioning
Quality System is approved by LRQA in accordance with the
standards UNI EN ISO 9001: 1994.
Each unit is supplied complete with a Test Certificate and
Declaration of Conformity.
All Challenger Plus units carry the “CE” mark and fully
comply with European Directives concerning mechanical,
electrical and electromagnetic safety.
Features
• New fan section - single inlet, radial centrifugal fans (plug
fans) with backward curved blades. Variable speed motor
with external rotor. Available static pressure up to 350 Pa,
standard configuration
• High COP (Co-efficient Of Performance)
• High SHR (Sensible Heat Ratio)
• Low energy consumption; High EER (Energy Efficiency
Ratio)
• Low operating cost
• All materials used in the unit are fully recyclable
• Low internal air-side pressure drop
• High efficiency filtration, up to EU8 available
• Modular construction
• Sandwich construction of panels with non-flammable Class 0 (ISO 1182.2) insulation
Applications
The Challenger Plus unit is ideally suited for precision close
control of the following types of environment:
• Data processing centers
• Telecommunications
• Industrial applications
The design of the Challenger Plus unit can vary depending on
the application, consult the Liebert Applications Engineering
Department for specific details.
2
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Introduction (continued)
System types
Air cooled units
Air cooled models consist of an evaporator coil, a compliant
scroll compressor, high and low pressure switches, an
externally equalised, adjustable, thermostatic expansion
valve, service ports, refrigerant line sight glass, liquid
receiver with pressure-relief valve and filter drier. The units
are shipped with a holding charge of dry Nitrogen.
Models CP20A, CP24A, CP28A, CP34A and CP40A are
single circuit. Models CP26A, CP32A, CP42A and CP46A
are dual circuit.
Air cooled units require matched air cooled condensers. Fan
speed controlled condensers are available from Liebert for a
full range of outside ambient temperatures. Refer to the
Condensers Technical Data Manual (P/N SLE CD TDM) for
full details.
Figure 1 - Air Cooled Downflow Unit
SLE CP TDM E.1 (06/99)
Water/Glycol cooled units
Water/Glycol cooled models consist of an evaporator coil, a
com pli ant scroll com pres sor, high and low pres sure
switches, an externally equalised, adjustable, thermostatic
expansion valve, service ports, refrigerant line sight glass,
filter drier, stainless-steel plate heat ex changer and a
head-pressure control valve (water regulating valve).
Pressure relief valves are fitted downstream of the plate heat
exchanger. The refrigerant circuits are precharged with
refrigerant in the factory.
Models CP20W, CP24W, CP28W, CP34W, CP40W are
single circuit. Models CP26W, CP32W, CP42W and CP46W
are dual circuit.
The units operate with mains water, cooling tower water or
water in a closed circuit with an external drycooler.
When operating in a closed circuit, it may be necessary
(depending on outside temperatures) to add monoethylene
glycol to prevent the water freezing in winter, refer to the unit
Installation Manual for applicable percentages.
A pump is used to circulate water (water/glycol) through the
unit (not supplied as standard).
If mains water or tower water is used, it is recommended to fit
a mechanical filter on the water line to protect the plate heat
exchanger against possible impurities contained in the water
(for plate heat exchanger cleaning, refer to the Installation
Manual).
Figure 2 - Water/Glycol Cooled Upflow Unit
3
Challenger Plus - Technical Data Manual
Introduction (continued)
Freecooling units
Freecooling mod els con sist of an evapo ra tor coil, a
com pli ant scroll com pres sor, high and low pres sure
switches, an externally equalised, adjustable, thermostatic
expansion valve, service ports, refrigerant line sight glass,
fil ter drier, stainless- steel plate heat ex changer, a
head-pressure control valve (water regulating valve), a
2-way modulating valve and a freecooling coil. Pressure
re lief valves are fit ted down stream of the plate heat
exchanger. The refrigerant circuits are precharged with
refrigerant in the factory.
Models CP20F, CP24F, CP28F, CP34F, CP40F are single
circuit. Models CP26F, CP32F, CP42F and CP46F are dual
circuit.
The units operate with water in a closed circuit from an
external drycooler.
When operating in a closed circuit, it may be necessary
(depending on outside temperatures) to add monoethylene
glycol to prevent the water freezing in winter, refer to the unit
Installation Manual for applicable percentages.
A pump is used to circulate water (water/glycol) through the
unit (not supplied as standard).
Operation
Freecooling units have two modes of operation, depending
on the outside temperature.
In normal operation, the unit cools the air in the conditioned
space using the compressor and refrigerant coil (direct
expansion).
When outside temperatures are low enough, water from the
external drycooler is used to cool the air in the conditioned
Figure 3 - Freecooling Upflow Unit
4
space directly using the Freecooling coil. This temperature is
the ZET or Zero Energy Temperature.
Dual source air cooled
Dual Source Air Cooled models consist of an evaporator
coil, a compliant scroll compressor, high and low pressure
switches, an externally equalised, adjustable, thermostatic
expansion valve, service ports, refrigerant line sight glass,
liquid receiver with pressure-relief valve, filter drier, 3-way
motorised modulating valve and a chilled water coil. The
units are shipped with a holding charge of dry Nitrogen.
Models CP20D, CP24D, CP28D, CP34D and CP40D are
single circuit. Models CP26D, CP32D, CP42D and CP46D
are dual circuit.
Air cooled units require matched air cooled condensers. Fan
speed controlled condensers are available from Liebert for a
full range of outside ambient temperatures. Refer to the
Condensers Technical Data Manual (P/N SLE CD TDM) for
full details.
Operation
In normal operation, when the temperature of the second
source is low enough, the chilled water coil is used to cool the
air in the conditioned space. If the temperature of the chilled
water rises above the temperature required to maintain the
load, chilled water cooling is stopped and the compressor is
started. The load is then maintained using dx cooling.
Figure 4 - Dual Source Air Cooled Downflow Unit
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Introduction (continued)
Dual source water/glycol cooled
Dual Source Water/Glycol cooled models consist of an
evaporator coil, a compliant scroll compressor, high and low
pressure switches, an externally equalised, adjustable,
thermostatic expansion valve, service ports, refrigerant line
sight glass, filter drier, stainless-steel plate heat exchanger, a
head-pressure control valve (water regulating valve), a
3-way motorised modulating valve and a chilled water coil.
Pressure relief valves are fitted downstream of the plate heat
exchanger. The refrigerant circuits are precharged with
refrigerant in the factory.
Models CP20H, CP24H, CP28H, CP34H, CP40H are single
circuit. Models CP26H, CP32H, CP42H and CP46H are dual
circuit.
Normal Operation
In normal operation, when the temperature of the second
source is low enough, the chilled water coil is used to cool the
air in the conditioned space. If the temperature of the chilled
water rises above the temperature required to maintain the
load, chilled water cooling is stopped and the compressor is
started. The load is then maintained using dx cooling.
Figure 5 - Dual Source Water Cooled Upflow Unit
SLE CP TDM E.1 (06/99)
DX Operation
The units operate with mains water, cooling tower water or
water in a closed circuit with an external drycooler.
When operating in a closed circuit, it may be necessary
(depending on outside temperatures) to add monoethylene
glycol to prevent the water freezing in winter, refer to the unit
Installation Manual for applicable percentages.
A pump is used to circulate water (water/glycol) through the
unit (not supplied as standard).
If mains water or tower water is used, it is recommended to fit
a mechanical filter on the water line to protect the plate heat
exchanger against possible impurities contained in the water
(for plate heat exchanger cleaning, refer to the Installation
Manual).
Chilled water cooled
Chilled water models incorporate a chilled water coil with a
three-way modulating motorised chilled water valve and
insulated piping.
Figure 6 - Chilled Water Cooled Downflow Unit
5
Challenger Plus - Technical Data Manual
Standard features - all systems
Air distribution
Access/Maintenance
Rou tine main te nance ac cess to re frig er ant cir cuit
components, compressor, liquid receiver, thermal expansion
valve, sight glass, filter dryer etc. is available through the
front panel of the unit. Service access to the air filter, the fan,
humidifier, electric panel, electronic controller PCB, electric
reheats etc. is also through the unit front panel.
Customer connections to the refrigerant circuit (hot gas and
liquid line), cooling water circuits, mains power input
supply, humidifier water supply and condensate drain lines
are located in the base of the unit.
The compressor is housed in a separate airtight compartment
within the unit, allowing access to the compressor while the
unit is in operation.
Cabinet and panels
The cabinet is manufactured from zintec, painted with
epoxy-polyester powder paint and assembled using stainless
steel screws.
All units in the range are available in three configurations,
Down flow, Up flow Front Return and Up flow Bot tom
Return, refer to Figure 7.
Fan section
The unit is fitted with a direct-drive, single inlet backward
curved, galvanized painted steel radial centrifugal fan (plug
fan). The fan motor is a three-phase, 25-speed motor (speed
is adjustable via an autotransformer). The motor is rated to
IP44 and complete with internal thermal protection.
The fan impeller is statically and dynamically balanced and
equipped with self-lubricating bearings. The fan is mounted
on vibration-absorbing rubber supports to reduce vibration
transmission between the fan and the unit frame. This
vibration attenuation helps to keep noise emission to a
minimum. The motor is capable of providing the rated
airflow at external static pressures of up to 350 Pa.
The front and rear panels are double-skinned, with 22mm
fiberglass insulation sandwiched between the panels to
reduce noise emission and heat loss. The side panels, which
are isolated from the inside of the unit, are lined with 22mm
fiberglass insulation sealed in an aluminum foil.
The edges of the panels are fitted with seals to prevent air loss
and to keep noise levels to an absolute minimum.
The structure is fully in compliance with Class 0 (ISO
1182.2). All surfaces in contact with the air flow are
washable in order to reduce the formation of bacteria. All
materials used are CFC-free and may be recycled.
Figure 8 - Autotransformer and Fan
Figure 7 - Air Distribution
6
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Standard features - all systems (continued)
Filtration
The air filter is made of synthetic fiber cells in a cardboard
frame and is designed to minimise the air pressure drop while
main tain ing maxi mum fil ter ef fi ciency. It is eas ily
accessed/replaced by opening the front doors of the unit.
The guaranteed efficiency is EU4 (Eurovent EU4/5, 30%
efficiency), (G4, CEN standard). Optional filtration levels to
EU8 (G8) are available on request.
Prefilters are available on upflow models.
Electrical panel
The electric panel, located at the front of the unit in an airtight
compartment, contains the MCB’s, contactors, transformer,
controller PCB and overload relays etc. Each high voltage
system component is provided with a separate overcurrent
protective device. All high-voltage components are touch
protected by means of a plastic cover. The electric panel
complies with the EN 60204-1.
The following alarms are standard:
• High temperature
• Low temperature
• Fan failure
• High pressure alarm – (compressorised systems only)
• Low pressure alarm - (compressorised systems only)
• Electrical reheat high temperature
• Memory failure
• Common alarm
Other alarms are also available when the relevant option is
ordered with the unit (e.g. if a humidifier is ordered with the
unit, the High Humidity, Low Humidity etc. alarms are
enabled). For a full list of all the options and alarms available
with the Microface controller, refer to the Microface
Controller Operation Manual (P/N SLE MF OM).
The controller also incorporates a sequential auto-restart
timer, allowing field adjustable time delays to be applied to
unit restart after a power loss (or other shutdown). The timers
al low mul ti ple units to be re started while lim it ing
instantaneous inrush current.
All units are designed for operation at 400V/3ph/50 Hz ( +
10%) and are fitted with a mains disconnect switch.
Microprocessor controller Microface
T h e M i c r o f a c e e n v i r o n m e n t a l c o n t r o l s y s t e m is
microprocessor based and can be programmed to match the
unique needs of any application. The processor integrates the
sepa rate me chani cal and elec tri cal com po nents into a
‘state-of-the-art’ conditioned space support system that
controls and monitors temperature, humidity, air flow and air
cleanliness.
The control system offers a tailored and well proven advance
in reliability and control flexibility allowing the unit to
modify its performance in response to changing critical space
conditions.
The controller allows local monitoring and programming of
the following room conditions:
Temperature (oC)
Temperature setpoint (5.0oC – 40.0 oC in steps of 0.1 oC)
Temperature sensitivity (1.0oC - 10oC in steps of 0.1 oC)
Humidity (%RH)
Humidity setpoint (20%RH - 80%RH in steps of 1%)
Humidity sensitivity (5%RH - 20%RH in steps of 1%)
The parameters are enunciated using symbols and text on an
LCD display. Normal operating modes are indicated by
symbols on the display. Alarm conditions activate a visual
indicator.
SLE CP TDM E.1 (06/99)
7
Challenger Plus - Technical Data Manual
Standard features - all systems (continued)
Electric reheat
The three-stage reheat is of rigid design for extended
operational life. The reheat has ample capacity to maintain
room dry- bulb con di tions dur ing a sys tem call for
de hu midi fi ca tion. The low- watt den sity, elec tri cally
enclosed elements are made of aluminum surrounded by high
ef fi ciency fins, re duc ing sheath tem pera tures and
eliminating ionisation. The reheat is phase-balanced.
Reheat control is of the ON-OFF type. The reheat is provided
with a manual reset, reheat safety thermostat, to disable the
reheat in the event of high temperature.
The reheat safety stat. also incorporates a magneto-thermal
switch which protects the reheat from short circuits, should
the harness be damaged accidentally.
Electric reheat can be combined with hot gas or hot water
reheat activated in different stages.
Refer to the Technical Data Tables for reheat capacities,
FLA’s etc.
Humidifier
The unit is fitted with an electronic steam bottle humidifier
suitable for use with water of varying degrees of hardness,
provided that the water is not treated or demineralized. The
humidifier is complete with a water inlet valve, a water outlet
valve and a maximum water level sensor.
The steam cyl in der is in stalled in the unit’s air tight
compartment to avoid heat losses. Steam from the cylinder is
mixed with the discharge air from the evaporating coil by
means of a copper steam distributor.
The unit controller monitors the condition of the steam
cylinder, and generates an alarm when the cylinder needs to
be changed. Cylinder replacement is easy and quick.
The humidifier is complete with a self-adapting flow control
system which monitors water conductivity and controls the
electrical current passing through the cylinder. Output
adjustment is from 30 - 100% via the unit controller.
Humidification control may be of the proportional or of the
on-off type, according to the requirements of the installation:
On-off control is set as standard.
Refer to the Optional section of the Technical Data Tables for
humidifier capacities, FLA’s, etc.
8
Dehumidification
On air-cooled models, the unit dehumidifies the air by
reducing the airflow across the coil (the fan is switched to a
lower speed) and switching on the compressor.
In chilled water models, the unit dehumidifies by fully
opening the chilled water valve.
In Dual Source units, the unit dehumidifies using the
"Current" cooling source. If the current source is DX, the unit
dehumidifies the air by reducing the airflow across the coil
(the fan is switched to a lower speed) and switching on the
compressor. If the current source is chilled water, the unit
dehumidifies by fully opening the chilled water valve.
In Freecooling units, the unit disables freecooling on a call
for dehumidification and dehumidifies the air by reducing
the airflow across the coil (the fan is switched to a lower
speed) and switching on the compressor.
Packaging
As standard, the units are wrapped in bubble-wrap to protect
painted surfaces, enclosed in a cardboard box and mounted
on a wooden pallet.
On request, for sea transport etc., the units can be packed in
wooden crates or cases complete with silicon desiccant.
Warranty clauses
The warranty does not cover any damage or malfunction of
the unit which may occur during or as a result of operating
the unit outside of the specified application limits.
Liebert does not accept responsibility for any damage caused
by improper use of the product.
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Standard features - DX systems (continued)
Refrigerant circuit
• Rubber mounting to ensure reduced compressor noise and
vibration.
Units are available as single and dual circuit. The circuit(s)
consist of a compressor, a thermal expansion valve, a liquid
line sight glass, a filter dryer, an evaporator coil, a liquid
re ceiver (air cooled only) and high and low pres sure
switches.
For safety reasons, (especially during machine start-up), it is
recommended to install a non-return valve(s) (supplied as an
option, on request) on the liquid line from the condenser, to
pro tect the com pres sor from un ex pected re frig er ant
migrations. All low temperature parts of the refrigerant
circuit are insulated as standard.
• IP54 protection
Evaporator
Sight glass
The evaporator coils are designed to provide maximum coil
area for more precise control of temperature and humidity.
With this computer designed coil arrangement, low velocity
air passes through the coil providing the most effective
surface exposure with less turbulence and greater efficiency
in the cooling and dehumidification processes. The coil is
designed for the high sensible heat ratio required by critical
spaces. The coil is tested to 30 Bar.
The evaporator coil is made of copper tubes with treated
aluminum fins (to withstand corrosive atmospheres). A
corrosion resistant drain pan is provided with the coil on all
models.
Refrigerant line sight glasses serve as a means of quick visual
inspection to determine if there is moisture in the system and
if the system is properly charged.
Schraeder connections are fitted to the unit for service
access.
Refrigerant
R22 HCFC is the standard refrigerant used in the Challenger
Plus range. An optional “Green” refrigerant, R407C is also
available. In this case the compressor is supplied with ester
oil. Air cooled units are shipped with a nitrogen holding
charge, water, dual source water and freecooling units are
charged with refrigerant in the factory.
Filter-dryer
Liq uid line filter- dryers ensure a clean, moisture- free
refrigerant system for extended component life. The filter
drier is suitable for use with standard R22 and optional “Zero
ODP” refrigerant R407C.
Expansion valve
The externally equalised, adjustable, thermostatic expansion
valve smoothly controls refrigerant flow during varying
indoor heat loads and outdoor ambient temperatures by
controlling evaporator superheat.
Safety controls
Each compressor has a manual-reset high pressure switch for
high pressure protection and a high pressure alarm circuit to
warn of high system pressures, allowing corrective action to
be taken before a significant loss of temperature control
occurs.
The low pressure switch is auto-resetting and detects low
pressure conditions such as loss of refrigerant charge. The
pres sure switch cali bra tion val ues are shown in the
Installation, Operation & Maintenance Manual supplied
with the machine.
Figure 9 - Scroll Compressor
Compressors
The fully hermetic compliant scroll compressor incorporates
several safety features for protection during normal and the
occasional abnormal operating conditions. They are:
Crankcase heaters
Crankcase heaters are supplied with all compressorised
models. They maintain minimum refrigerant temperature
and are en er gised while the unit is pow ered and the
compressor is off.
• Self resetting overloads to sense excessive currents and
temperatures.
• An internal pressure relief valve which limits discharge
pressure to protect mechanical parts.
• Motor insulation that is resistant to chemical attack.
SLE CP TDM E.1 (06/99)
9
Challenger Plus - Technical Data Manual
Standard features - DX models (continued)
Air cooled only
Liquid receiver
A welded steel liquid receiver is provided to maintain
constant and even refrigerant flow to the expansion valve, in
all circumstances. Shut-off valves are installed as standard on
the inlet and outlet of the receiver to assist maintenance of the
circuit, if required.
A suitably rated pressure relief valve is installed on the liquid
receiver. The valve is equipped with a threaded connection to
al low the re frig er ant to be dis charged out side of the
conditioned space.
Air cooled condenser
A matching Liebert air cooled condenser with fan speed
control should be ordered with the unit. Details of the
condensers are provided in this manual, full details of all
condensers for all outdoor ambients are available in the
Condenser Technical Data Manual, (P/N SLE CD TDM).
Note: The suggested condenser selections/performances for
each outdoor ambient are based on calculated data. The
actual selection of a condenser should always be verified on
the basis of the specific working conditions on each site.
Water cooled/freecooling units only
Plate heat exchanger
All water cooled units (models W, H, F) are fitted with a
brazed plate heat exchangers made of stainless steel. This
type of condenser is designed for high efficiency heat
exchange. The condenser is intentionally oversized for the
application to reduce pressure drops (and the energy
consumption of the circulation pump) in the water supply and
thus allow the unit to operate with an external water cooler in
a closed circuit at high outdoor temperatures. Pressure relief
valves are fitted downstream of the condenser. The valve is
equipped with a threaded connection to allow the refrigerant
to be discharged outside of the conditioned space.
Drycooler
A drycooler can be supplied, if required. Full details of all
drycoolers are available in the Drycooler Technical Data
Manual, P/N SLE DC TDM.
Head pressure control valve
Head pressure operated regulating valves accurately control
the condensing temperature and system capacity for various
entering fluid temperatures. A 2-way head pressure control
valve is fitted as standard on water/glycol cooled, dual source
water cooled and freecooling units.
The valve controls the condensing pressure by regulating the
water flow to the plate condenser. It is installed at the
condenser outlet with the pressure probe positioned on the
refrigerant discharge line. It is automatically closed when the
compressor is not operating. It is sized for inlet water flow
temperatures lower than 17 0C resulting in low water-side
pressure drops.
For higher water inlet temperatures, higher water flowrates
are required and possibly special water regulating valves,
consult Liebert Applications Engineers for details.
Freecooling only
Freecooling coil
The Freecooling coil is located on the return air side of the
evaporator coil. Water/glycol flow to the coil is controlled by
a pre-piped 2-way modulating motorised valve. When
sup plied with a coolant so lu tion of suf fi ciently low
temperature, the coil is sufficiently sized to offer an equal
cooling capacity to that obtained using the refrigeration
circuit. The coil is tested to 30 Bar.
2-way control valve
As the out door am bi ent drops to a suf fi ciently low
temperature, the 2-way motorised valve modulates the flow
to the coil, as in a chilled water system. The valve includes an
operating linkage and electric motor.
Water cooled units can operate with mains water, cooling
tower water or water in a closed circuit with an external
drycooler. Freecooling units operate with water in a closed
circuit from an external drycooler only.
When operating in a closed circuit, it may be necessary
(depending on outside temperatures) to add monoethylene
glycol to prevent the water freezing in winter , refer to the unit
Installation Manual for applicable percentages.
A pump is used to circulate water (water/glycol) through the
unit (it is not supplied).
If mains water or tower water is used, it is recommended to fit
a mechanical filter on the water line to protect the condenser
against possible impurities contained in the water (for
condenser cleaning, refer to the Installation Manual).
10
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Standard features - DX models (continued)
Outdoor operating range (Air cooled - A, D)
Lower limit
-20°C with fan speed control installed in the condenser.
Upper limit
This is determined by the capacity of the condenser coupled
to the unit (at the relevant outdoor ambient). If the limit is
exceeded, the High Pressure Switch will shut the compressor
down. The switch must then be manually reset after the
problem has been rectified.
Condenser installation
Condenser above indoor unit
Figure 10 - Head Pressure Control Valve
Dual source only
Dual source units consist of the standard direct expansion
refrigeration circuit and an additional cooling coil with a
three-way motorised modulating valve.
The additional coil is located on the return air side of the
evaporator coil. Flow to the coil is controlled by a pre-piped
3-way equal percentage motorised valve.
The normal control strategy of the unit is to use the secondary
source (chiller supply, process water supply etc.) to maintain
the room load until a sensor detects that the secondary source
is no longer at the required temperature. Direct expansion
cooling is then switched on and maintains the load.
Maximum distance between indoor unit and external air
condenser: 30 meters equivalent length.
Condenser below indoor unit
Maximum geodetic height difference between condenser
and unit: 3 meters.
Air flow
The mini mum and maxi mum air flows and avail able
External Static Pressure are given in the Technical Data
section of this manual. The fan motor thermal overload
protects the unit from any damage which could result from
operating outside the specified values.
Voltage tolerance
All models 400 V ± 10%
Frequency tolerance
50 Hz ± 2 Hz.
Operating limits (DX models)
Challenger Plus direct expansion units are designed for
operation within the following working limits (the limits are
applicable to newly commissioned machines which have
been correctly installed and maintained).
Indoor operating range
All models from 18.0°C, 45% R.H. to 27.0°C, 55% R.H.
To minimise the possibility of water carry over, (i.e. too
much condensate on the evaporator coil leading to the
formation of water droplets), it is critical to ensure that the
latent load (difference between total and sensible load) does
not exceed 5.5 kW.
SLE CP TDM E.1 (06/99)
11
Challenger Plus - Technical Data Manual
Standard features - chilled water models
Cooling coil
The large face area/low face velocity, deep wave fin coil
allows precise control of temperature and humidity during
cooling and dehumidification, and is designed to optimize
fluid velocity and minimize pressure drop. The full face area
is active during cooling and dehumidification, resulting in
op era tional en ergy sav ing in the ap pli ca tion area. A
corrosion resistant drain pan is provided on all models. The
coil is tested to 30 Bar.
3-way control valve
The motorised chilled water valve provides equal percentage
control action in response to room temperature and humidity
as sensed by the mi cro proc es sor. This re sults in a
proportional ratio of capacity to stem travel. The valve
includes an operating linkage and electric motor. The valve
can be manually adjusted to the closed position (on the
coil-side of the valve) using the tool provided.
Operating limits
Challenger Plus chilled water units are designed for
operation within the following working limits (the limits are
applicable to newly commissioned machines which have
been correctly installed and maintained).
Indoor operating range
All models from 18.0°C, 45% R.H. to 27.0°C, 55% R.H.
To minimise the possibility of water carry over, (i.e. too
much condensate on the evaporator coil leading to the
formation of water droplets), it is critical to ensure that the
latent load (difference between total and sensible load) does
not exceed 5.5 kW
Air flow
The mini mum and maxi mum air flows and avail able
External Static Pressure are given in the Technical Data
section of this manual. The fan motor thermal overload
protects the unit from any damage which could result from
operating outside the specified values.
Voltage tolerance
All models 400 V ± 10%
Frequency tolerance
50 Hz ± 2 Hz.
Figure 11 - Equal Percentage Valve Characteristic
12
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Optional features - all models
Hot gas reheat
Challenger Plus can be supplied with a hot gas reheat coil if
required. This type of reheat uses the heat which is normally
rejected in the condenser to heat the air in the conditioned
space, thus saving energy. A control valve prevents the
refrigerant from flowing to the reheating coil when reheat is
not required. The reheat coil is single or double row
depending on the model, and constructed of copper tubes
with aluminum fins.
When hot gas reheat is requested, it is supplied in conjunction
with electrical reheat in two stages as follows:
Stage 1: Hot gas reheat
Stage 2: Hot gas reheat + electrical reheat
Note: The capacity of the electrical reheat in stage 2 is equal
to two thirds of the total capacity of the standard electrical
reheat for a given model.
Refer to the Optional section of the Technical Data Tables for
reheat capacities etc.
Hot water reheat
The economical hot water reheats are controlled by a 3-way
(on/off) valve from the microprocessor control panel. The
system is completely pre-piped and includes an air bleed
valve. The reheat coil is single or double row depending on
the model, and constructed of copper tubes with aluminum
fins. The coil is tested to a pressure of 30 bar.
A hot water thermostat (provided by the customer) is used in
the valve control sequence to determine the availability of
reheat capacity.
When hot water reheat is requested, it is sup plied in
conjunction with electrical reheat in two stages as follows:
Stage 1: Hot water reheat
Stage 2: Hot water reheat + electrical reheat
Note: The capacity of the electrical reheat in stage 2 is equal
to two thirds of the total capacity of the standard electrical
reheat for a given model.
Refer to the Optional section of the Technical Data Tables for
reheat capacities etc.
Non-return valves (models A and D)
Re frig er ant non- return valves for air-cooled units are
available as an option.
The valve is installed on the liquid line, close to the
condenser and mounted vertically.
Liebert recommend that the valve be installed when the total
system charge exceeds the specified values given in the
Optional section of the Technical Data Tables.
High efficiency filters
EU5 filters
Optional 100mm EU5 high efficiency filters are available for
all models. The high efficiency filters are interchangeable
with the standard filters. The filters are EU5 (Eurovent 4/5),
filtration class G4 (CEN standards).
EU6, EU7 and EU8 filters
Optional 290mm high efficiency filters, class EU6, EU7 and
EU8 (Eurovent 4/5), are available on request. The filters are
made of fi ber glass fil ter me dia. The fil ter me dia is
constructed in ”V” sections with a rigid external frame to
withstand high pressure drops and flow variations.
If these filters are ordered, a 600mm filter plenum is required
to house them. The plenum is of the same colour as the unit
and installed on the top of the unit. (Refer to Options section
of the Technical Data Tables for details).
Figure 12 - EU6, EU7, EU8 Filters
SLE CP TDM E.1 (06/99)
13
Challenger Plus - Technical Data Manual
Optional features - all models (continued)
Filter clog switch
An adjustable differential pressure switch can be fitted to
initiate a change filter alarm when a pre-selected pressure
drop across the filter bank is exceeded.
Water detection sensors
A water detection sensor, containing an isolated switch that
closes when water (or other conductive liquid) is detected by
the sensor probes may be ordered as an option. The sensor is
hermetically sealed, robust and should be fitted in the
location where water problems might occur.
Smoke alarm
Fresh air kit
The fresh air intake kit is recommended for use where the
conditioned space is continuously occupied. The kit consists
of a cylindrical EU3 filter mounted in the unit which
connects to a 100mm diameter duct (the flexible duct can
also be supplied if the length is specified).
The fresh air is then mixed with the discharge air from the
unit through a slot on the intake side of the fan.
Floorstand
Floorstands are available in a range of heights, 300mm,
500mm and 800mm. Each height of floorstand is fitted with
adjustable legs (± 25mm). The floorstands permit installation
and connection of the system prior to installation of the raised
floor.
Turning vane
A smoke detector/alarm is available as an option. The smoke
detector will activate the alarm and stop the unit if smoke is
detected in the return air. The sensor is an optic smoke
detector (Tyndall effect) which is insensitive to light or air
movement.
A factory installed turning vane may be specified to direct the
air as required within the floorstand.
Firestat
A firestat/alarm is available as an option. The firestat
deactivates the unit when the return air temperature is too
high. The firestat can be mounted in the unit or remotely,
consult Applications Engineers for details. The detector is
complete with an NTC thermistor.
Environmental Alarm Package
The Electronic Environmental Alarm Package (EEAP) is a
remote temperature and relative humidity sensor (additional
to the internal sensor) connected to the unit controller.
Figure 13 - Floorstand
The sensor can be installed up to 20m from the unit and
generates an alarm if the temperature or the relative humidity
exceeds one of the 4 user-set limits:
• HighTemperature Limit
(Adjustable from 10°C to 50°C)
• Low Temperature Limit
(Adjustable from 0°C to 30°C)
• High Humidity Limit
(Adjustable from 30% to 99%)
• Low Humidity Limit
(Adjustable from 10% to 70%).
14
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Optional features - all models (continued)
Base module - upflow units only
A 200mm base module can be supplied on request to support
upflow Challenger Plus units. The module is used when
customer connections must be made through the base of the
unit, but no false floor is available.
Alternatively the base module can be used for bottom air
return where there is no raised floor.
Figure 15 - Sound Attenuation Cartridge
Special packaging
Figure 14 - Base Module
Sound attenuation package
In applications where sound emission from the unit is of
critical importance, a special sound attenuating cartridge,
attached to the top of the unit, is available to reduce sound
levels to an absolute minimum.
The cartridges, made of a self-extinguishing material with a
high at tenua tion ca pac ity are guar an teed against
disintegration and release of particles due to friction within
the duct.
It is possible to install one or two rows of cartridges in the
plenum depending on the sound attenuation required. A
single row requires a 600 mm high plenum, two rows require
a 1200 mm high plenum.
A single cartridge in a 600mm high plenum provides a noise
reduction of -8.5 dB(A) at 2 m in front of the unit and 1.5 m
from the ground. A single cartridge in a 1200mm high
plenum provides a noise reduction of -13 dB(A) at 1 m in
front of the unit and at an angle of 45o to the unit top.
A double cartridge in a 1200mm plenum will provides a noise
reduction of -9.5 dB(A) at 2 m in front of the unit and 1.5 m
from the ground. It will provide a noise reduction of -14
dB(A) at 1 m in front of the unit and at an angle of 45o to the
unit top.
Refer to the Options section of the Technical Data Tables for
further details.
SLE CP TDM E.1 (06/99)
Where the unit is to be transported by sea or in other cases
where heavy duty packaging is required, special crating is
available.
This can consist of either a wooden crate over the standard
carboard/bubble wrap packaging or the entire unit can be
encased in a wooden box.
Special packing for sea transport, consisting of a wooden box
or crate in addition to normal cardboard, can be supplied on
request.
Figure 16 - Special Packaging
15
Challenger Plus - Technical Data Manual
Optional features - all models (continued)
Plenum
Condensate pump
An intake/supply plenum is available for connection between
the unit and a false ceiling. The plenum is manufactured from
the same material and in the same colour as the unit.
The plenum consists of sandwich panels lined with class 0
(ISO 1182.2), 30 kg/m3 density, non-flammable insulation.
Available heights range from 600 mm to 1200 mm.
Plenum with fixed grille (upflow)
A condensate drain pump can be supplied if required. The
pump is complete with a flow cutout switch allowing the
pump to stop and reset automatically. Depending on the unit
type, it can be supplied fitted or loose for field fitting, consult
Liebert Applications Engineers for details. The following
table lists pump capacity vs. available head.
Flow (l/s)
Available Head (kPa)
A supply air plenum with fixed horizontal air flow can be
installed on top of the unit. The 900 mm high plenum is
manufactured from the same material and in the same colour
as the unit.
The plenum consists of sandwich panels lined with class 0
(ISO 1182.2), 30 kg/m3 density, non-flammable insulation.
Plenum with adjustable louvered grille
(upflow)
A supply air plenum with adjustable (up and down) air flow
can be installed on top of the unit. The 900 mm high plenum is
manufactured from the same material and in the same colour
as the unit.
The plenum consists of sandwich panels lined with class 0
(ISO 1182.2), 30 kg/m3 density, non-flammable insulation.
Caution is advised against extreme deflection of the louvers
as this can obstruct the air flow and reduce the unit’s cooling
capacity.
0.083
0.167
0.250
0.333
20
19
18
14
Air intake from the bottom (upflow
models)
Upflow models are normally front return. If required, they
can be supplied as bottom return. Bottom return models are
fitted with a blank front panel (this reduces the sound level of
the unit).
Dampers
Challenger Plus units can be provided with motorised
shut-off dampers for downflow models and gravity-fed
dampers for upflow models.
Alternative refrigerant R407C
An optional “green” refrigerant, R407C can be supplied with
all compressorised models.
The compressor is filled with a special ester oil required for
R407C. Air cooled units are filled ex-factory with a holding
charge of dry nitrogen. Water, Dual Source Water and
Freecooling units are charged with R407C.
Figure 17 - Plenum with grille
16
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Optional features - all models (continued)
Hiromatic graphic
The Hiromatic Graphic is a purpose-designed control system
for precision air-conditioning. It simultaneously monitors
the critical space and signals alarms either locally or
re motely. The graph ics screen dis plays all the ma jor
pa rame ters, in clud ing sym bolic rep re sen ta tion of unit
func tions, such as heat ing, cool ing etc.; in ad di tion
temperature and humidity variations with time can be
pre sented graphi cally on the screen. All di ag nos tic
procedures, including the checking and calibration of input
and output signals, and of the microprocessor itself, can be
run from the front panel. The con troller al lows local
moni tor ing and pro gram ming of the fol low ing room
conditions:
Temperature (oC)
Temperature setpoint (5.0– 40.0oC in steps of 0.1oC)
Temperature sensitivity (1.0 - 10oC in steps of 0.1 oC)
Humidity (%RH)
Humidity setpoint (20%RH - 80%RH in steps of 1%)
Humidity sensitivity (5%RH - 20%RH in steps of 1%)
The Hiromatic Graphic can be supplied installed in a unit, or
in kit form for installation in a remote control panel.
BEMS Interface
The Hiromatic Graphic allows units on a network to be
integrated with the Hirolink Communications Bus when an
RS422 card is installed at the back of Hiromatic. Hiromatic
can control up to 8 Microface units in this configuration and
communicate the relevant data to Hirolink.
Hirolink works as a communications manager between the
Hi ro matic Graphic and Mi cro face units and in dus try
stan dard field bus ses and pro to cols used in Build ing
Management Systems such as Mod-Bus, J-Bus, Satchwell,
etc.
Note: For full details of the Hiromatic Graphic, refer to the
Hiromatic Graphic Operations Manual, (P/N SLE HG OM).
A full range of alarms, High and Low Temperature, High and
Low Humidity, Fan Failure, High and Low Pressure etc. are
standard with the controller.
Features
• Backlit LCD graphics display
• User interface via pushkeys
• Battery-backed clock for date/time and real time functions
• Password control for setpoints, unit/control setup and
service functions
• Graphics display of temperature and humidity over a 24
hour period
The Hiromatic Graphic is menu-driven and user menu’s are
available in 10 languages. The Hiromatic Graphic records the
last 120 “events” (Alarms, Warnings etc.) occurring in the
system along with a “Graphic Data Record” for the unit. The
Graphic Data Record displays the temperature and humidity
readings for the last 24 hours (stored since the last start-up of
the unit).
The Hiromatic Graphic controls date and time functions
using them as operating information for the customer and as a
reference whenever a status change occurs, logging the status
change in the “Status Report”. Details of the event which
occurred, the date and time at which the event occurred are
also stored. Using buffered RAM, the Hiromatic also stores
the operating hours of each component (compressor, fan,
electric heaters, humidifier etc.) for each connected unit.
A further feature of the Hiromatic Graphic is “Sleep Mode”.
Sleep Mode allows units to be programmed to switch on and
off at different times of the day, and on different days of the
week.
SLE CP TDM E.1 (06/99)
17
Challenger Plus - Technical Data Manual
Air cooled data - downflow units (R407C)+
MODEL
CP20AD CP24AD CP28AD CP34AD CP40AD CP26AD CP32AD
Refrigerant Circuit
-
Single
CP42AD
CP46AD
Double
PERFORMANCE DATA (1)
m3/h
5800
6600
9980
11040
12510
9980
11040
12510
Pa
450
380
430
400
370
430
400
370
320
Total Capacity
kW
19.6
24.9
32.7
36.1
47.3
29.2
34.7
41.9
54.0
Sensible Capacity
kW
18.8
23.2
29.5
33.5
42.6
28.0
33.3
41.1
47.0
Air Flow
Available ESP
(2)
13500
Sensible Heat Ratio
-
0.96
0.93
0.90
0.93
0.90
0.96
0.96
0.98
0.87
Energy Output/Input
-
3.39
3.25
3.37
3.20
3.49
3.24
3.25
3.42
3.44
Sound Pressure Level (3)
dB(A)
51.1
54.4
56.4
57.5
59.0
56.4
57.5
59.0
60.8
Comp.Power Absorbed
kW
4.80
6.37
7.53
8.91
10.93
6.84
8.32
9.60
12.76
2 x 11.8
A
11.1
11.8
14.7
16.2
18.9
2 x 6.5
2 x 8.0
2 x 11.1
Fan Power Absorbed
Comp.Current Absorbed
kW
0.98
1.31
2.17
2.34
2.65
2.17
2.34
2.65
2.96
Fan Current Absorbed
A
3.9
4.2
2 x 4.1
2 x 4.1
2 x 4.2
2 x 4.1
2 x 4.1
2 x 4.2
2 x 4.3
Total Power Absorbed
kW
5.8
7.7
9.7
11.3
13.6
9.0
10.7
12.3
15.7
2x6
2 x 7.8
FAN SECTION
Quantity
Type
1
2
-
Single inlet, backward curved, radial centrifugal fan (plug fan)
COMPRESSOR SECTION
Quantity
1
2
Type
Rated power
Scroll compressor
HP
6
7.8
9
10
13
2x4
2x5
EVAPORATOR COIL
Quantity
n.
1
Tubes/Fins
Coil Surface Area
Configuration
Copper tubes / Treated aluminium fins
m2
0.74
1.49
-
Inclined
REFRIGERANT CONNECTIONS (Brazed, O.D.)
Hot Gas Line
mm
18
22
28
16
18
22
Liquid Line
mm
16
18
22
14
16
18
DIMENSIONS
Width
mm
Depth
mm
Height
mm
Footprint
m2
1000
1750
890
1950
0.89
1.56
WEIGHTS
+
Net
kg
380
385
580
585
590
590
595
600
605
Gross
kg
385
390
585
590
595
595
600
605
610
R22 Capacities are approximately the same as R407C capacities + 5%. Consult Liebert Applications Engineers for specific details.
1
At the following standard conditions: 24°C db; 50% R.H. (17°C wb) - condensing temperature: 49°C.
Power Supply Voltage 400/3/50, 20Pa ESP (External Static Pressure)
2
Max available ESP at quoted airflow
3
Measured in front of the unit at 1m height, 2 m distance, in the free field, fan and compressor running, 20Pa ESP.
Note: Quoted capacities are gross capacities, for nett capacities, deduct fan motor kW. EER is based on indoor unit only. Unit air flow is quoted for standard
configuration, with a clean EU4 filter.
18
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Air cooled data - upflow units (R407C)+
MODEL
CP20AU
CP24AU
Refrigerant Circuit
CP28AU
CP34AU CP40AU CP26AU CP32AU CP42AU CP46AU
Single
Double
PERFORMANCE DATA (1)
Air Flow
Available ESP
(2)
m3/h
5785
6690
9820
10790
12465
9820
10790
12465
13201
Pa
450
380
430
370
330
430
370
330
280
Total Capacity
kW
19.4
24.7
32.5
36.3
47.0
29.3
34.4
40.8
53.0
Sensible Capacity
kW
18.6
22.7
28.9
33.4
42.8
27.8
33.0
40.8
46.2
Sensible Heat Ratio
-
0.96
0.92
0.89
0.92
0.91
0.95
0.96
1.0
0.87
Energy Output/Input
-
3.28
3.17
3.28
3.09
3.35
3.18
3.08
3.21
3.28
Sound Pressure Level (3)
dB(A)
52.7
55.8
57.8
60.0
61.6
57.8
60.0
61.6
62.9
Comp. Power Absorbed
kW
4.80
6.37
7.53
8.91
10.92
6.84
8.32
9.60
12.74
Comp. Current Absorbed
kW
11.1
11.8
14.7
16.2
18.9
2 x 6.5
2 x 8.0
2 x 11.1
2 x 11.8
Fan Power Absorbed
kW
1.12
1.42
2.37
2.85
3.11
2.37
2.85
3.11
3.41
Fan Current Absorbed
A
4.1
4.3
2 x 4.1
2 x 4.3
2 x 4.4
2 x 4.1
2 x 4.3
2 x 4.4
2 x 4.4
Total Power Absorbed
kW
5.9
7.8
9.9
11.8
14.0
9.2
11.2
12.7
16.2
2x6
2 x 7.8
FAN SECTION
Quantity
1
2
Type
Single inlet, backward curved, radial centrifugal fan (plug fan)
COMPRESSOR SECTION
Quantity
1
2
Type
Rated power
Scroll compressor
HP
6
7.8
9
10
13
2x4
2x5
EVAPORATOR COIL
Quantity
1
Tubes/Fins
Coil Surface Area
Configuration
Copper tubes / Treated aluminium fins
m2
0.74
1.49
-
Inclined
REFRIGERANT CONNECTIONS (Brazed, O.D.)
Hot Gas Line
mm
22
28
18
22
Liquid Line
mm
18
22
16
18
DIMENSIONS
Width
mm
Depth
mm
890
Height
mm
1950
Footprint
1000
2
m
1750
0.89
1.56
WEIGHTS
+
Net
kg
390
395
590
595
600
600
605
610
615
Gross
kg
395
400
595
600
605
605
610
615
620
R22 Capacities are approximately the same as R407C capacities + 5%. Consult Liebert Applications Engineers for specific details.
1
At the following standard conditions: 24°C db; 50% R.H. (17°C wb) - condensing temperature: 49°C.
Power Supply Voltage 400/3/50, 50Pa ESP (External Static Pressure)
2
Max available ESP at quoted airflow
3
Measured in front of the unit at 1m height, 2 m distance, in the free field, fan and compressor running, 50Pa ESP.
Note: Quoted capacities are gross capacities, for nett capacities, deduct fan motor kW. EER is based on indoor unit only. Unit air flow is quoted for standard
configuration, with a clean EU4 filter.
SLE CP TDM E.1 (06/99)
19
Challenger Plus - Technical Data Manual
Water cooled data - downflow units (R407C)+
MODEL
CP20WD CP24WD CP28WD CP34WD CP40WD CP26WD CP32WD CP42WD CP46WD
Refrigerant Circuit
Single
Double
PERFORMANCE DATA (1)
Air Flow
m3/h
5800
6600
9980
11040
12510
9980
11040
12510
13500
Available ESP (2)
Pa
450
380
430
400
370
430
400
370
320
Fan Power Absorbed
kW
0.98
1.31
2.17
2.34
2.65
2.17
2.34
2.65
2.96
Fan Current Absorbed
A
3.9
4.2
2 x 4.5
2 x 4.1
2 x 4.2
2 x 4.1
2 x 4.1
2 x 4.2
2 x 4.3
Sound Pressure Level (3)
dB(A)
51.1
54.4
56.4
57.5
59.0
56.4
57.5
59.0
60.8
Water inlet temperature: 24°C - Condensing Temperature: 40.5°C (0% glycol)
Total Cooling Capacity
kW
21.5
28.2
35.6
40.5
51.0
32.3
38.0
45.3
58.1
Sensible Cooling Capacity
kW
19.6
24.3
30.2
35.2
43.9
29.1
34.5
42.2
48.2
SHR Sensible Heat Ratio
0.91
0.86
0.85
0.87
0.86
0.90
0.91
0.93
0.83
EER (Energy Out/Input)
4.35
4.28
4.23
4.19
4.31
4.15
4.09
4.28
4.28
Water Flow Rate
l/s
0.40
0.66
0.79
0.87
1.16
0.62
0.79
0.87
1.39
Total Water Pressure Drop (4)
kPa
7+5
18 + 13
7 + 11
8+8
14 + 11
3+8
4 + 14
2+6
5 + 15
Comp. Power Absorbed
kW
3.97
5.30
6.22
7.31
9.18
5.60
6.92
7.94
10.60
Comp. Current Absorbed
A
10.3
10.4
12.81
14.3
16.4
2 x 5.8
2 x 7.2
2 x 10.3
2 x 10.4
Total Power Absorbed
kW
4.95
6.60
8.40
9.66
11.82
7.78
9.27
10.59
13.57
Water inlet temperature: 30°C - Condensing Temperature: 45°C (0% glycol)
Total Cooling Capacity
kW
20.7
27.1
34.0
38.3
49.5
31.0
36.6
43.5
56.7
Sensible Cooling Capacity
kW
19.5
24.1
29.9
34.5
43.5
28.8
34.0
41.8
48.2
SHR (Sensible Heat Ratio)
0.94
0.89
0.88
0.90
0.88
0.93
0.93
0.96
0.85
EER (Energy Out/Input)
3.85
3.79
3.74
3.66
3.87
3.70
3.67
3.78
3.86
Water Flow Rate
l/s
0.49
0.82
0.98
1.03
1.41
0.73
0.95
1.05
1.74
Total Water Pressure Drop (4)
kPa
7+26
20+73
16+40
12+45
16+83
12+15
19+25
8+16
23+31
Comp. Power Absorbed
kW
4.4
5.8
6.9
8.1
10.1
6.2
7.6
8.8
11.7
Comp. Current Absorbed
A
10.7
11.1
13.7
15.3
17.6
2 x 6.1
2 x 7.6
2 x 10.7
2 x 11.1
Total Power Absorbed
kW
5.4
7.1
9.1
10.5
12.8
8.4
10.0
11.5
14.7
FAN SECTION
Quantity
n.
1
2
Type
Single inlet, backward curved, radial centrifugal fan (plug fan)
COMPRESSOR SECTION
Quantity
n.
1
2
Type
Scroll compressor
Rated power
HP
6
7.8
9
10
13
2x4
2x5
2x6
2 x 7.8
EVAPORATOR COIL
Quantity
1
Tubes/Fins
Copper tubes / Treated aluminium fins
Coil Surface Area
m2
0.74
1.49
Orientation
Inclined
CONDENSER
Type
Plate-heat exchanger in stainless steel (AISI 316)
Quantity
1
2
Water Connections
inch
1”
1¼“
1/2"
1”
DIMENSIONS
Length
mm
1000
1750
Depth
mm
890
Height
mm
1950
Footprint
m2
0.89
1.56
WEIGHTS
Net
kg
390
395
590
595
600
600
605
610
615
Gross
kg
395
400
595
600
605
605
610
615
620
+
R22 Capacities are approximately the same as R407C capacities + 5%. Consult Liebert Applications Engineers for specific details.
At the following standard conditions: 24°C db; 50% R.H. (17°C wb), Power Supply Voltage 400/3/50, 20Pa ESP (External Static Pressure).
2
Max available ESP at quoted airflow
3
Measured in front of the unit at 1m height, 2 m distance, in the free field, fan and compressor running, 20Pa ESP.
4
Valve pressure drop + condenser pressure drop.
5
Valve pressure drop + coil pressure drop.
Note: Quoted capacities are gross capacities, for nett capacities, deduct fan motor kW. EER is based on indoor unit only. Unit air flow is quoted for standard
configuration, with a clean EU4 filter.
1
20
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Water cooled data - upflow units (R407C)+
MODEL
CP20WU CP24WU CP28WU CP34WU CP40WU CP26WU CP32WU CP42WU CP46WU
Refrigerant Circuit
Single
Double
PERFORMANCE DATA (1)
Air Flow
m3/h
5785
6690
9820
10790
12465
9820
10790
12465
13200
Available ESP (2)
Pa
450
380
430
370
330
430
370
330
280
Fan Power Absorbed
kW
1.12
1.42
2.37
2.85
3.11
2.37
2.85
3.11
3.41
Fan Current Absorbed
A
4.1
4.3
2 x 4.1
2 x 4.3
2 x 4.4
2 x 4.1
2 x 4.3
2 x 4.4
2 x 4.4
Sound Pressure Level (3)
dB(A)
52.7
55.8
57.8
60.0
61.6
57.8
60.0
61.6
62.9
Water inlet temperature: 24°C - Condensing Temperature: 40.5°C (0% glycol)
Total Cooling Capacity
kW
21.1
27.3
35.3
40.0
50.7
31.5
36.9
44.8
57.9
Sensible Cooling Capacity
kW
19.2
24.0
30.0
34.8
44.1
28.6
34.0
42.1
48.0
SHR Sensible Heat Ratio
0.91
0.88
0.85
0.87
0.87
0.91
0.92
0.94
0.83
EER (Energy Out/Input)
4.14
4.06
4.11
3.93
4.13
3.95
3.78
4.05
4.13
Water Flow Rate
l/s
0.39
0.62
0.78
0.85
1.15
0.62
0.78
0.85
1.36
Total Water Pressure Drop (4)
kPa
6+5
16 + 11
6 + 10
8+8
14 + 11
3+8
4 + 13
2+5
5 + 14
Comp. Power Absorbed
kW
3.97
5.29
6.22
7.31
9.17
5.60
6.92
7.94
10.60
Comp. Current Absorbed
A
10.3
10.4
12.8
14.3
16.4
2 x 5.8
2 x 7.2
2 x 10.3
2 x 10.4
Total Power Absorbed
kW
5.09
6.71
8.60
10.16
12.28
7.98
9.77
11.05
14.01
Water inlet temperature: 30°C - Condensing Temperature: 45°C (0% glycol)
Total Cooling Capacity
kW
20.3
26.2
33.6
38.0
49.0
30.5
36.1
43.1
55.4
Sensible Cooling Capacity
kW
19.1
23.9
29.6
34.2
43.7
28.4
33.6
41.4
47.1
SHR (Sensible Heat Ratio)
0.94
0.91
0.88
0.90
0.89
0.93
0.93
0.96
0.85
EER (Energy Out/Input)
3.08
3.03
3.63
3.46
3.68
3.56
3.45
3.59
3.65
Water Flow Rate
l/s
0.48
0.78
1.00
1.02
1.40
0.72
0.94
1.03
1.70
Total Water Pressure Drop (4)
kPa
7+25
18+65
16+39
12+43
16+81
11+14
19+24
9+11
21+30
Comp. Power Absorbed
kW
4.4
5.8
6.9
8.1
10.1
6.2
7.6
8.8
11.7
Comp. Current Absorbed
A
10.7
11.1
13.7
15.3
17.6
2 x 6.1
2 x 7.6
2 x 10.7
2 x 11.1
Total Power Absorbed
kW
6.6
8.6
9.3
11.0
13.3
8.6
10.5
12.0
15.2
FAN SECTION
Quantity
1
2
Type
Single inlet, backward curved, radial centrifugal fan (plug fan)
COMPRESSOR
Quantity
1
2
Type
Scroll compressor
Rated power
HP
6
7.8
9
10
13
2x4
2x5
2x6
2 x 7.8
EVAPORATOR COIL
Quantity
1
Tubes/Fins
Copper tubes / Treated aluminium fins
Coil Surface Area
m2
0.74
1.49
Orientation
Inclined
CONDENSER
Type
Plate-heat exchanger in stainless steel (AISI 316)
Quantity
1
2
Water Connections
inch
1”
1¼“
1/2"
1”
DIMENSIONS
Length
mm
1000
1750
Depth
mm
890
Height
mm
1950
Footprint
m2
0.89
1.56
WEIGHTS
Net
kg
400
405
600
605
610
610
615
620
625
Gross
kg
405
410
605
610
615
615
620
625
630
+
R22 Capacities are approximately the same as R407C capacities + 5%. Consult Liebert Applications Engineers for specific details.
At the following standard conditions: 24°C db; 50% R.H. (17°C wb), Power Supply Voltage 400/3/50, 50Pa ESP (External Static Pressure)
2
Max available ESP at quoted airflow
3
Measured in front of the unit at 1m height, 2 m distance, in the free field, fan and compressor running, 50Pa ESP.
4
Valve pressure drop + condenser pressure drop.
5
Valve pressure drop + coil pressure drop.
Note: Quoted capacities are gross capacities, for nett capacities, deduct fan motor kW. EER is based on indoor unit only. Unit air flow is quoted for standard
configuration, with a clean EU4 filter.
1
SLE CP TDM E.1 (06/99)
21
Challenger Plus - Technical Data Manual
Air cooled dual source data - downflow units (R407C)+
MODEL
CP20DD CP24DD CP28DD CP34DD CP40DD CP26DD CP32DD CP42DD CP46DD
Refrigerant circuit
Single
Double
PERFORMANCE (1)
Air Flow
m3/h
5570
6280
9980
10960
11910
9980
10960
11910
13100
Available ESP (2)
Pa
435
325
410
390
340
410
390
340
280
Fan Power Absorbed
kW
1.15
1.57
2.46
2.78
3.00
2.45
2.67
2.99
3.47
Fan Current Absorbed
A
4.11
4.41
2 x 4.16
2 x 4.25
2 x 4.35
2 x 4.16
2 x 4.25
2 x 4.35 2 x 4.423
PERFORMANCE WITH MECHANICAL COOLING
Total Cooling Capacity
kW
19.5
25.7
32.7
36.4
47.5
29.2
34.4
41.1
54.4
Sensible Cooling Capacity
kW
18.9
23.2
29.5
33.5
42.7
28.0
33.1
41.1
47.9
SHR (Sensible Heat Ratio)
0.97
0.90
0.90
0.92
0.90
0.96
0.96
1.0
0.88
EER(Energy Out/Input)
3.28
3.24
3.28
3.15
3.41
3.15
3.13
3.26
3.35
Sound Pressure Level (3)
dB(A)
51.3
55.4
55.8
57.6
59.1
55.8
57.6
59.1
61.2
Comp. Power Absorbed
kW
4.8
6.37
7.53
8.91
10.93
6.84
8.32
9.6
12.8
Comp.Current Absorbed
A
11.1
11.8
14.7
16.19
18.9
2 x 6.5
2 x 7.98 2 x 11.11 2 x 11.83
Total Power Absorbed
kW
5.95
7.94
9.98
11.6
13.92
9.3
11.0
12.6
16.22
PERFORMANCE WITH CHILLED WATER COOLING
Total Cooling Capacity
kW
24.5
29.6
51.7
63.5
67.3
51.7
63.5
67.3
71.9
Sensible Cooling Capacity
kW
21.8
25.5
42.4
48.9
52.5
42.4
48.9
52.5
56.8
Sound Pressure Level (3)
dB(A)
50.8
54.9
55.3
57.1
58.6
55.3
57.1
58.6
60.7
Inlet/Outlet Water Temp.
°C
7/12
7/12
7/12
7/12
7/12
7/12
7/12
7/12
7/12
Water Flow Rate
l/s
1.17
1.41
2.5
3.03
3.21
2.5
3.03
3.21
3.43
Total Water Pressure Drop (4)
kPa
18 + 15
10 + 16
31 + 48
46 + 52
21 + 58
31 + 48
46 + 52
21 + 58
24 + 64
FAN SECTION
Quantity
1
2
Type
Single inlet, backward curved, radial centrifugal fan (plug fan)
COMPRESSOR
Quantity
1
2
Type
Scroll
Rated Power
HP
6
7.8
9
10
13
2x4
2x5
2x6
2 x 7.8
EVAPORATING COIL
Quantity
1
Tubes/fins
Copper tubes / Treated aluminium fins
Coil Surface Area
m2
0.74
1.49
Orientation
Inclined
CHILLED WATER CONNECTIONS (MALE THREADED)
Water Connections
inch
1”
1¼“
1½“
1¼“
1½“
REFRIGERANT CONNECTIONS (Brazed, O.D.)
Hot Gas Line
mm
18
22
28
16
18
22
Liquid Line
mm
16
18
22
14
16
18
DIMENSIONS
Length
mm
1000
1750
Depth
mm
890
Height
mm
1950
Footprint
m2
0.89
1.56
WEIGHTS
Net
kg
500
510
790
795
800
805
810
815
820
Gross
kg
505
515
795
800
805
810
815
820
825
+
R22 Capacities are approximately the same as R407C capacities + 5%. Consult Liebert Applications Engineers for specific details.
At the following standard conditions: 24°C db; 50% R.H. (17°C wb) - condensing temperature: 49°C, Power Supply Voltage 400/3/50, 20Pa ESP (External
Static Pressure)
2
Max available ESP at quoted airflow
3
Measured in front of the unit at 1m height, 2 m distance, in the free field, fan and compressor running, 20Pa ESP.
4
Valve pressure drop + coil pressure drop.
5
Valve pressure drop + condenser pressure drop.
Note: Quoted capacities are gross capacities, for nett capacities, deduct fan motor kW. EER is based on indoor unit only. Unit air flow is quoted for standard
configuration, with a clean EU4 filter.
1
22
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Air cooled dual source data - upflow units (R407C)+
MODEL
CP20DU CP24DU CP28DU CP34DU CP40DU CP26DU CP32DU CP42DU CP46DU
Refrigerant circuit
Single
Double
PERFORMANCE (1)
Air Flow
m3/h
5640
6350
9880
10480
11860
9880
10480
11860
12850
(2)
Available ESP
Pa
435
325
410
350
305
410
350
305
240
Fan Power Absorbed
kW
1.24
1.66
2.62
2.94
3.46
2.62
2.94
3.46
3.87
Fan Current Absorbed
A
4.173
4.41
2 x 4.21 2 x 4.307
2 x 4.4
2 x 4.21
2 x 4.31
2 x 4.4
2 x 4.44
PERFORMANCE WITH MECHANICAL COOLING
Total Cooling Capacity
kW
18.8
24.3
32.7
35.9
46.7
29.4
33.5
40.3
53.0
Sensible Cooling Capacity
kW
18.1
22.6
29.5
32.7
42.1
28.3
32.2
40.3
46.1
SHR (Sensible Heat Ratio)
0.96
0.93
0.90
0.91
0.90
0.96
0.96
1.00
0.87
EER(Energy In/Output)
3.12
3.02
3.22
3.03
3.25
3.11
2.97
3.09
3.19
Sound Pressure Level (3)
dB(A)
52.9
57.1
57.8
58.10
61.6
57.8
58.1
61.6
63.4
Comp. Power Absorbed
kW
4.80
6.4
7.53
8.90
10.92
6.84
8.32
9.60
12.74
Comp. Current Absorbed
A
11.09
11.83
14.7
16.17
18.88
2 x 6.48
2 x 7.99
2 x 11.1 2 x 11.83
Total Power Absorbed
kW
6.04
8.03
10.15
11.84
14.38
9.45
11.26
13.06
16.62
PERFORMANCE WITH CHILLED WATER COOLING
Total Cooling Capacity
kW
24.6
29.8
50.8
58.6
63.9
50.8
58.6
63.9
67.4
Sensible Cooling Capacity
kW
21.9
25.6
41.7
46.3
51.1
41.7
46.3
51.1
54.6
Sound Pressure Level (3)
dB(A)
52.4
56.6
57.3
57.6
61.1
57.3
57.6
61.1
62.9
Inlet/Outlet Water
°C
7/12
7/12
7/12
7/12
7/12
7/12
7/12
7/12
7/12
Temperature
Water Flow Rate
l/s
1.2
1.42
2.42
2.8
3.04
2.42
2.8
3.04
3.21
Total Water Pressure Drop (4)
kPa
18 + 15
10 + 16
30 + 47
40 + 46
19 + 53
30 + 47
40 + 46
19 + 53
21 + 58
FAN SECTION
Quantity
1
2
Type
Single inlet, backward curved, radial centrifugal fan (plug fan)
COMPRESSOR
Quantity
1
2
Type
Scroll compressor
Rated Power
HP
6
7.8
9
10
13
2x4
2x5
2x6
2 x 7.8
EVAPORATOR COIL
Quantity
1
Tubes/Fins
Copper tubes / Treated aluminium fins
Coil Surface Area
m2
0.74
1.49
Orientation
Inclined
CHILLED WATER CONNECTIONS (MALE THREADED)
Water Connections
inch
1”
1¼“
1½“
1¼“
1½“
REFRIGERANT CONNECTIONS (Brazed, O.D.)
Hot Gas Line
mm
18
22
28
16
18
22
Liquid line
mm
16
18
22
14
16
18
DIMENSIONS
Length
mm
1000
1750
Depth
mm
890
Height
mm
1950
Footprint
m2
0.89
1.56
WEIGHTS
Net
kg
500
510
790
795
800
815
820
825
830
Gross
kg
505
515
795
800
805
820
825
830
835
+
R22 Capacities are approximately the same as R407C capacities + 5%. Consult Liebert Applications Engineers for specific details.
At the following standard conditions: 24°C db; 50% R.H. (17°C wb) - condensing temperature: 49°C.
Power Supply Voltage 400/3/50, 50Pa ESP (External Static Pressure)
2
Max available ESP at quoted airflow
3
Measured in front of the unit at 1m height, 2 m distance, in the free field, fan and compressor running, 50Pa ESP.
4
Valve pressure drop + coil pressure drop.
5
Valve pressure drop + condenser pressure drop.
Note: Quoted capacities are gross capacities, for nett capacities, deduct fan motor kW. EER is based on indoor unit only. Unit air flow is quoted for standard
configuration, with a clean EU4 filter.
1
SLE CP TDM E.1 (06/99)
23
Challenger Plus - Technical Data Manual
Water cooled dual source data - downflow units (R407C)+
MODEL
CP20HD
CP24HD
CP28HD
CP34HD
CP40HD
CP26HD
CP32HD
CP42HD
CP46HD
Refrigerant Circuit
Single
Double
PERFORMANCE WITH MECHANICAL COOLING(1)
Air Flow
m3/h
5570
6280
9980
10960
11910
9980
10960
11910
13100
(2)
Available ESP
Pa
435
325
410
390
340
410
390
340
280
Fan Power Absorbed
kW
1.15
1.57
2.46
2.68
3.00
2.45
2.67
2.99
3.47
Fan Current Absorbed
A
4.11
4.41
2 x 4.16
2 x 4.25
2 x 4.35
2 x 4.16
2 x 4.23
2 x 4.35 2 x 4.423
Sound Pressure Level (3)
dB(A)
51.3
55.4
55.8
57.6
59.1
55.8
57.6
59.1
61.2
Water inlet temperature: 24°C - Condensing Temperature: 40.5°C (0% glycol)
Total Cooling Capacity
kW
21.0
27.9
35.6
40.0
51.1
32.3
37.6
45.2
58.6
Sensible Cooling Capacity
kW
19.3
24.0
30.2
34.8
44.0
29.1
34.3
42.0
49.2
SHR (Sensible Heat Ratio)
0.92
0.86
0.85
0.87
0.86
0.90
0.91
0.93
0.84
EER(Energy Out/Input)
4.11
4.06
4.10
4.01
4.20
4.00
3.92
4.13
4.16
Water Flow Rate
l/s
0.392
0.653
0.791
0.853
1.158
0.621
0.792
0.875
1.404
Total Water Pressure Drop(5)
kPa
6+5
18 + 13
7 + 11
8+8
14 + 11
3+8
4 + 14
2+6
5 + 15
Comp. Power Absorbed
kW
3.97
5.29
6.22
7.31
9.18
5.60
6.92
7.94
10.60
Comp. Current Absorbed
A
10.33
10.40
12.81
14.34
16.38
2 x 5.78
2 x 7.24 2 x 10.32 2 x 10.4
Total Power Absorbed
kW
5.12
6.86
8.67
9.99
12.17
8.06
9.60
10.94
14.07
Water inlet temperature: 30°C - Condensing Temperature: 45°C (0% glycol)
Total Cooling Capacity
kW
20.3
27.0
34.0
38.2
49.6
31.0
36.3
43.3
56.7
Sensible Cooling Capacity
kW
19.3
23.8
29.9
34.4
43.6
28.8
33.7
41.6
48.7
Total Power Absorbed
kW
5.5
7.3
8.3
10.7
13.0
7.6
10.2
11.7
15.0
Comp. Power Absorbed
kW
4.4
5.8
6.9
8.1
10.1
6.2
7.6
8.8
11.7
Comp. Current Absorbed
A
10.7
11.1
13.7
15.3
17.6
2 x 6.1
2 x 7.6
2 x 10.7
2 x 11.1
SHR (Sensible Heat Ratio)
0.95
0.88
0.88
0.90
0.88
0.93
0.93
0.96
0.86
EER (Energy Out/Input)
3.52
3.26
3.61
3.22
3.36
3.79
3.31
3.56
3.24
Water Flow Rate
l/s
0.47
0.82
0.98
1.03
1.41
0.73
0.95
1.06
1.75
Total Water Pressure Drop(5)
kPa
7+9
20 + 28
16 +10
12 + 11
16 + 21
12 + 15
19 + 24
8 + 12
23 + 32
PERFORMANCE WITH CHILLED WATER COOLING
Total Cooling Capacity
kW
24.5
29.6
51.7
63.5
67.3
51.7
63.5
67.3
71.9
Sensible Cooling Capacity
kW
21.8
25.5
42.4
48.9
52.5
42.4
48.9
52.5
56.8
Sound Pressure Level
dB(A)
51.0
55.1
55.5
57.3
58.8
55.5
57.1
58.6
60.7
Water Inlet/Outlet
°C
7/12
7/12
7/12
7/12
7/12
7/12
7/12
7/12
7/12
Water Flow Rate
l/s
1.17
1.41
2.46
3.03
3.21
2.46
3.03
3.21
3.430
Total Water Pressure Drop (4)
kPa
18 + 15
10 + 16
31 + 48
46 + 52
21 + 58
31 + 48
46 + 52
21 + 58
24 + 64
FANS SECTION
Quantity
1
2
Type
Single inlet, backward curved, radial centrifugal fan (plug fan)
COMPRESSOR
Quantity
1
2
Type
Scroll compressor
Rated Power
HP
6
7.8
9
10
13
2x4
2x5
2x6
2 x 7.8
EVAPORATOR COIL/CHILLED WATER
Quantity
2
Tubes/Fins
Copper tubes / Treated aluminium fins
Coil Surface Area
m2
0.74
1.49
Orientation
Inclined
CONDENSER
Type
Plate-heat exchanger in stainless steel (AISI 316)
Quantity
1
2
Water Connections
inch
1”
1¼“
1/2"
1"
CHILLED WATER CONNECTIONS (MALE THREADED)
Water Connections
inch
1”
1¼“
1½“
1¼“
1½“
DIMENSIONS
Length
mm
1000
1750
Depth
mm
890
Height
mm
1950
Footprint
m2
0.89
1.56
WEIGHTS
Net
kg
500
510
790
795
800
810
815
820
825
Gross
kg
505
515
795
800
805
815
820
825
830
See Page 22 for applicable notes.
24
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Water cooled dual source data - upflow units (R407C)+
MODEL
CP20HU
CP24HU
CP28HU
CP34HU
CP40HU
CP26HU
CP32HU
CP42HU
CP46HU
Refrigerant Circuit
Single
Double
PERFORMANCE WITH MECHANICAL COOLING(1)
Air Flow
m3/h
5640
6350
9880
10480
11860
9880
10480
11860
12850
Available ESP (2)
Pa
435
325
410
350
305
410
350
305
240
Fan Power Absorbed
kW
1.24
1.66
2.62
2.94
3.46
2.62
2.94
3.46
3.87
Fan Current Absorbed
A
4.173
4.408
2 x 4.21 2 x 4.307 2 x 4.398 2 x 4.21 2 x 4.307
2 x 4.4
2 x 4.44
Sound Pressure Level (3)
dB(A)
52.9
57.1
57.8
58.1
61.6
57.8
58.1
61.6
63.4
Water inlet temperature: 24°C - Condensing Temperature: 40.5°C (0% glycol)
Total Cooling Capacity
kW
20.3
26.5
35.2
39.5
50.8
31.7
35.7
44.4
57.3
Sensible Cooling Capacity
kW
18.7
23.3
30.3
33.9
43.7
28.9
32.8
41.3
48.1
SHR (Sensible Heat Ratio)
0.92
0.88
0.86
0.86
0.86
0.91
0.92
0.93
0.84
EER(Energy Out/Input)
3.90
3.81
3.98
3.85
4.03
3.86
3.62
3.89
3.96
Water Flow Rate
l/s
0.371
0.593
0.791
0.826
1.138
0.621
0.749
0.851
1.364
Total Water Pressure Drop(5)
kPa
6+4
15 + 11
7 + 11
7+8
14 + 10
3+8
4 + 12
2+5
5 + 14
Comp. Power Absorbed
kW
3.96
5.29
6.22
7.31
9.17
5.60
6.92
7.94
10.60
Comp. Current Absorbed
A
10.34
10.38
12.81
14.33
16.38
2 x 5.78
2 x 7.24 2 x 10.32 2 x 10.4
Total Power Absorbed
kW
5.2
6.95
8.84
10.25
12.62
8.23
9.86
11.40
14.47
Water inlet temperature: 30°C - Condensing Temperature: 45°C (0% glycol)
Total Cooling Capacity
kW
19.8
25.5
34.2
37.7
49.1
30.5
34.5
42.7
55.9
Sensible Cooling Capacity
kW
18.5
23.2
30.1
33.6
42.7
28.6
32.4
41.0
47.5
SHR (Sensible Heat Ratio)
0.93
0.91
0.88
0.89
0.87
0.94
0.94
0.96
0.85
EER(Energy Out/Input)
3.56
3.45
3.65
3.40
3.69
3.49
3.26
3.52
3.62
Water Flow Rate
l/s
0.45
0.75
0.97
1.00
1.39
0.73
0.90
1.03
1.70
Total Water Pressure Drop(5)
kPa
6+8
17+23
16+10
11+10
15+20
12+15
17+22
9+11
21+30
Comp. Power Absorbed
kW
4.4
5.8
6.9
8.1
10.0
6.2
7.6
8.8
11.7
Comp. Current Absorbed
A
10.7
11.1
13.7
15.3
17.6
2 x 6.1
2 x 7.6
2 x 10.7
2 x 11.1
Total Power Absorbed
kW
5.6
7.4
9.4
11.1
13.3
8.7
10.6
12.1
15.5
PERFORMANCE WITH CHILLED WATER COOLING
Total Cooling Capacity
kW
24.6
29.8
50.8
58.6
63.9
50.8
58.6
63.9
67.4
Sensible Cooling Capacity
kW
21.9
25.6
41.7
46.3
51.1
41.7
46.3
51.1
54.6
Sound Pressure Level
dB(A)
52.4
56.6
57.3
57.6
61.1
57.3
57.6
61.1
62.9
Water Inlet/Outlet
°C
7/12
7/12
7/12
7/12
7/12
7/12
7/12
7/12
7/12
Water Flow Rate
l/s
1.170
1.420
2.420
2.80
3.040
2.42
2.80
3.040
3.210
Total Water Pressure Drop (4)
kPa
18 + 15
10 + 16
30 + 47
40 + 46
19 + 53
30 + 47
40 + 46
19 + 53
21 + 58
FAN SECTION
Quantity
1
2
Type
Single inlet, backward curved, radial centrifugal fan (plug fan)
COMPRESSOR
Quantity
1
2
Type
Scroll compressor
Rated Power
HP
6
7.8
9
10
13
2x4
2x5
2x6
2 x 7.8
EVAPORATOR COIL/CHILLED WATER
Quantity
2
Tubes/Fins
Copper tubes / Treated aluminium fins
Coil Surface Area
m2
0.74
1.49
Orientation
Inclined
CONDENSER
Type
Plate-heat exchanger in stainless steel (AISI 316)
Quantity
1
2
Water Connections
inch
1”
1¼“
1/2"
1"
CHILLED WATER CONNECTIONS (MALE THREADED)
Water Connections
inch
1”
1¼“
1½“
1¼“
1½“
DIMENSIONS
Length
mm
1000
1750
Depth
mm
890
Height
mm
1950
Footprint
m2
0.89
1.56
WEIGHTS
Net
kg
500
510
790
795
800
820
825
830
835
Gross
kg
505
515
795
800
805
825
830
835
840
See Page 22 for applicable notes.
SLE CP TDM E.1 (06/99)
25
Challenger Plus - Technical Data Manual
Freecooling data - downflow units (R407C)+
MODEL
CP20FD CP24FD CP28FD CP34FD CP40FD CP26FD CP32FD CP42FD
Refrigerant Circuit
Single
Double
PERFORMANCE (1)
Air Flow
m3/h
5570
6280
9980
10960
11910
9980
10960
11910
(2)
Available ESP
Pa
435
325
410
390
340
410
390
340
Fan Power Absorbed
kW
1.15
1.48
2.45
2.67
2.99
2.45
2.67
2.99
Fan Current Absorbed
A
4.11
4.34
2 x 4.2
2 x 4.3
2 x 4.4
4.12
2 x 4.3
2 x 4.4
Glycol Concentration
%
25
25
25
25
25
25
25
25
PERFORMANCE WITH MECHANICAL COOLING
Total Cooling Capacity
kW
19.3
24.6
30.9
34.2
45.1
28.5
33.5
40.6
Sensible Cooling Capacity
kW
18.7
22.9
28.8
32.9
41.9
27.9
32.5
40.6
SHR (Sensible Heat Ratio)
0.97
0.93
0.93
0.96
0.93
0.98
0.97
1.00
EER (Energy Out/Input)
3.14
2.92
2.83
2.75
3.03
2.89
2.84
3.13
Sound Pressure Level (3)
dB(A)
51.3
54.9
55.8
57.6
59.1
55.8
57.6
59.1
0
Water Inlet Temperature
C
39.4
39.1
41.8
40.8
39.6
40.4
39.7
38.8
Condenser Water PD
kPa
37
37
55
43
38
38
38
37
Valve Water PD
kPa
53
53
35
41
52
13
13
13
Comp. Power Absorbed
kW
5.00
6.96
8.48
9.76
11.87
7.38
9.12
9.98
Comp. Current Absorbed
A
11.3
12.68
16.25
17.13
20.32
2 x 6.8
2 x 8.4
2 x 11.3
Total Power Absorbed
kW
6.16
8.44
10.93
12.44
14.87
9.84
11.8
12.98
PERFORMANCE IN FREECOOLING MODE
Total Cooling Capacity
kW
24.1
31.7
39.4
44.0
57.3
35.7
42.3
50.9
Sensible Cooling Capacity
kW
24.1
31.7
39.4
44.0
57.3
35.7
42.3
50.9
Sound Pressure Level
dB(A)
50.7
54.3
55.2
57.1
58.5
55.2
57.1
58.6
ZET
°C
2.8
0.8
4.1
5.1
3.5
4.3
3.3
5.1
Water Inlet Temp. (@ZET)
°C
8.9
6.4
11.5
11.8
9.3
11.0
9.7
10.5
Water FlowRate
l/s
1.06
1.06
1.73
1.88
2.10
1.29
1.29
2.13
Total Unit PD
kPa
30
27
71
46
56
42
24
58
Drycooler Model
DSL018 DSL018 DSL022 DSL028 DSL040 DSL022 DSL028 DSL040
Drycooler PD
kPa
7
11
25
29
17
15
15
17
FAN SECTION
Quantity
n.
1
2
Type
Single inlet, backward curved, radial centrifugal fan (plug fan)
COMPRESSOR
Quantity
n.
1
2
Type
Scroll compressor
Rated Power
HP
6
7.8
9
10
13
2x4
2x5
2x6
EVAPORATOR COIL
Quantity
1
Tubes/Fins
Copper tubes / Treated aluminium fins
Coil Surface Area
m2
0.74
1.49
Orientation
Inclined
CONDENSER
Type
Plate-heat exchanger in stainless steel (AISI 316)
Quantity
1
2
Water Connections
inch
1”
1¼“
DIMENSIONS
Length
mm
1000
1750
Depth
mm
890
Height
mm
1950
Footprint
m2
0.89
1.56
WEIGHTS
Net
kg
500
510
790
795
800
810
815
820
Gross
kg
505
515
795
800
805
815
820
825
CP46FD
13100
280
3.47
2 x 4.4
25
50.5
45.9
0.91
2.81
61.2
40.7
37
13
14.52
2 x 13.1
17.98
65.2
65.2
60.6
2.3
8.7
2.13
58
DSL040
17
2 x 7.8
825
830
+
R22 Capacities are approximately the same as R407C capacities + 5%. Consult Liebert Applications Engineers for specific details.
At the following standard conditions: 24°C db; 50% R.H. (17°C wb), Power Supply Voltage 400/3/50, 20Pa ESP (External Static Pressure).
o
External Ambient 32 C.
2
Max available ESP at quoted airflow
3
Measured in front of the unit at 1m height, 2 m distance, in the free field, fan and compressor running, 20Pa ESP.
Note: Quoted capacities are gross capacities, for nett capacities, deduct fan motor kW. EER is based on indoor unit only. Unit air flow is quoted for standard
configuration, with a clean EU4 filter.
ZET = Zero Energy Temperature. PD = Pressure Drop
1
26
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Freecooling data - upflow units (R407C)+
MODEL
CP20FU CP24FU CP28FU CP34FU CP40FU CP26FU CP32FU CP42FU
Refrigerant Circuit
Single
Double
PERFORMANCES (1)
Air Flow
m3/h
5640
6350
9880
10480
11860
9880
10480
11860
(2)
Available ESP
Pa
435
325
410
350
305
410
350
305
Fan Power Absorbed
kW
1.24
1.66
2.62
2.94
3.46
2.62
2.94
3.46
Fan Current Absorbed
A
4.12
4.41
2 x 4.2
2 x 4.31
2 x 4.4
2 x 4.21
2 x 4.31
2 x 4.4
Glycol Concentration
%
25
25
25
25
25
25
25
25
PERFORMANCE WITH MECHANICAL COOLING
Total Cooling Capacity
kW
18.6
23.5
30.9
33.7
45.0
28.5
31.6
40.0
Sensible Cooling Capacity
kW
18.1
22.3
28.8
32.0
41.4
27.9
31.6
40.0
SHR (Sensible Heat Ratio)
0.97
0.95
0.97
0.95
0.92
0.98
1.00
1.00
EER (Energy Out/Input)
3.01
2.76
2.79
2.66
2.94
2.85
2.65
2.98
Sound Pressure Level (3)
dB(A)
52.9
57.1
57.8
58.1
61.6
57.8
58.1
61.6
0
Water Inlet Temperature
C
39.2
38.8
41.8
40.7
39.6
40.4
39.5
38.7
Condenser Water PD
kPa
37
37
55
45
38
39
38
37
Valve Water PD
kPa
53
53
35
43
52
13
13
13
Comp. Power Absorbed
kW
4.96
6.85
8.48
9.7
11.83
7.38
9.02
9.94
Comp. Current Absorbed
A
11.26
12.53
16.22
17.06
20.25
2 x 6.8
2 x 8.4
2 x 11.3
Total Power Absorbed
kW
6.20
8.51
11.10
12.65
15.29
10.00
11.96
13.40
PERFORMANCE IN FREECOOLING MODE
Total Cooling Capacity
kW
23.5
30.3
39.4
43.6
56.8
35.6
41.0
50.2
Sensible Cooling Capacity
kW
23.5
30.3
39.4
43.6
56.8
35.6
41.0
50.2
Sound Pressure Level
dB(A)
52.4
56.5
57.2
57.5
60.9
57.2
57.6
61.1
ZET
°C
3.5
1.7
3.9
4.7
3.5
3.9
3.4
5.1
Water Inlet Temp. (@ZET)
°C
9.4
7.1
11.3
11.4
9.1
10.7
9.5
10.4
Water Flow Rate
l/s
1.06
1.06
1.72
1.92
2.10
1.29
1.29
2.13
Total Unit PD
kPa
30
27
71
48
56
42
24
58
Drycooler Model
DSL018 DSL018 DSL022 DSL028 DSL040 DSL022 DSL028 DSL040
Drycooler PD
kPa
7
11
25
31
17
15
15
17
FAN SECTION
Quantity
1
2
Type
Single inlet, backward curved, radial centrifugal fan (plug fan)
COMPRESSOR
Quantity
1
2
Type
Scroll compressor
Rated Power
HP
6
7.8
9
10
13
2x4
2x5
2x6
EVAPORATOR COIL
Quantity
1
Tubes/Fins
Copper tubes / Aluminium lanced fins
Coil Surface Area
m2
0.74
1.49
Orientation
Inclined
CONDENSER
Type
Plate-heat exchanger in stainless steel (AISI 316)
Quantity
1
2
Water Connections
inch
1”
1¼“
DIMENSIONS
Length
mm
1000
1750
Depth
mm
890
Height
mm
1950
Footprint
m2
0.89
1.56
WEIGHTS
Net
kg
500
510
790
795
800
810
Gross
kg
505
515
795
800
805
815
CP46FU
12850
240
3.87
2 x 4.4
25
50.1
45.0
0.90
2.73
63.4
40.3
37
13
14.44
2 x 13.0
18.31
64.3
64.3
62.9
2.2
8.5
2.13
58
DSL040
17
2 x 7.8
+
R22 Capacities are approximately the same as R407C capacities + 5%. Consult Liebert Applications Engineers for specific details.
1 At the following standard conditions: 24°C db; 50% R.H. (17°C wb), Power Supply Voltage 400/3/50, 50Pa ESP (External Static Pressure).
o
External Ambient 32 C.
2
Max available ESP at quoted airflow
3
Measured in front of the unit at 1m height, 2 m distance, in the free field, fan and compressor running, 50Pa ESP.
Note: Quoted capacities are gross capacities, for nett capacities, deduct fan motor kW. EER is based on indoor unit only. Unit air flow is quoted for standard
configuration, with a clean EU4 filter.
ZET = Zero Energy Temperature. PD = Pressure Drop
SLE CP TDM E.1 (06/99)
27
Challenger Plus - Technical Data Manual
Chilled water cooled data - downflow units
MODEL
Cooling Circuit
PERFORMANCE (1)
Air Flow
m3/h
(2)
Available ESP
Pa
Fan Power Absorbed
kW
Fan Current Absorbed
A
Sound Pressure Level(3) dB(A)
CP25CD
Single
CP35CD
Single
CP50CD
Single
CP60CD
Single
CP70CD
Single
CP75CD
Single
8000 7200 6400 7900 7110 6180 15000 13500 11800 14800 13300 11500 14540 13040 11300 14200 12700 11000
150 250 350 150 250 350 150 250 350 150 250 350 150 250 350 150 250 350
2.0 1.8 1.4 2.1 1.8 1.4 4.2 3.5 2.9 4.2 3.5 2.9 4.2 3.5 2.9 4.2 3.5 2.9
4.5 4.4 4.3 4.4 4.5 4.3 9.0 8.9 8.7 9.0 8.9 8.7 9.0 8.9 8.7 9.0 8.9 8.6
55.5
54.1
60.1
59.8
58.3
58.2
Inlet water temperature: 7°C - outlet water temperature: 12°C
Total Cooling Capacity
Sensible Capacity
Water Flow Rate
Water Pressure Drop
kW
kW
l/s
kPa
30.9 28.6 26.2 46.4 42.6 37.9 68.8 63.7 57.8 82.2 75.3 67.2 94.3 85.8 75.9 99.6 90.3 79.3
28.8 26.6 24.3 38.2 34.8 30.7 57.9 53.5 48.5 67.7 62.0 55.3 76.0 69.1 61.1 78.2 70.9 62.2
1.48 1.36 1.25 2.21 2.03 1.81 3.28 3.04 2.75 3.92 3.59 3.21 4.50 4.09 3.62 4.75 4.30 3.78
45
39
33
63
55
46 123 106 95 100 85
70
65
55
46
65
56
46
Inlet water temperature: 10°C - outlet water temperature: 15°C
Total Cooling Capacity kW 22.2 20.5 18.8 28.8 26.7 23.9 42.8 39.7 35.8 52.6 48.3 42.9 63.7 58.0 51.2 69.3 62.6 54.9
Sensible Capacity
kW 22.2 20.5 18.8 28.8 26.7 23.9 42.8 39.7 35.8 52.6 48.3 42.9 61.6 56.1 49.5 63.5 57.4 50.4
Water Flow Rate
l/s 1.06 0.98 0.90 1.38 1.27 1.14 2.04 1.90 1.71 2.51 2.31 2.05 3.04 2.77 2.44 3.31 2.99 2.62
Water Pressure Drop
kPa 33
29
25
28
24
19
65
49
41
50
43
36
28
23
28
30
26
22
FAN SECTION
Quantity
1
2
Type
Single inlet, backward curved, radial centrifugal fan (plug fan)
CHILLED WATER COIL
Quantity
1
2
1
2
Tubes/Fins
Copper tubes / Treated aluminium fins
Coil Surface Area
m2
0.74
1.49
Orientation
Inclined
CHILLED WATER CONNECTIONS
Water Connections
inch
1”
1¼“
1½“
DIMENSIONS
Length
mm
1000
1750
Depth
mm
890
Height
mm
1950
Footprint
m2
0.89
1.56
WEIGHTS
Net
kg
290
490
495
500
550
560
Gross
kg
295
495
500
505
555
565
1
At the following standard conditions: 24°C db; 50% R.H. (17°C wb), Power Supply Voltage 400/3/50, 20Pa ESP (External Static Pressure).
Max available ESP at quoted airflow
3
Measured in front of the unit at 1m height, 2 m distance, in the free field, fan and compressor running, 20Pa ESP.
Note: Quoted capacities are gross capacities, for nett capacities, deduct fan motor kW. Unit air flow is quoted for standard configuratio n, with a clean EU4
filter.
2
ESP = External Static Pressure
28
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Chilled water cooled data - upflow units
MODEL
Cooling Circuit
PERFORMANCES (1)
Air Flow
m3/h
Available ESP (2)
Pa
Fan Power Absorbed
kW
Fan Current Absorbed
A
Sound Pressure Level(3) dB(A)
CP25CU
Single
CP35CU
Single
CP50CU
Single
CP60CU
Single
CP70CU
Single
CP75CU
Single
8500 8000 7000 8100 7300 6350 14400 12900 11200 14000 12600 10900 14000 12600 10900 13300 12000 10360
150 250 350 150 250 350 150 250 350 150 250 350 150 250 350 150 250 350
2.1 1.9 1.5 2.2 1.9 1.5 4.4 3.8 3.0 4.4 3.8 3.0 4.4 3.8 3.0 4.3 3.8 3.0
4.5
4.4
4.4 4.5 4.4 8.8 8.9 8.7 8.8 8.9 8.7 8.8 8.9 8.7 8.7 8.8 8.6
58.2
55.2
60.6
60.4
Inlet water temperature: 7°C - outlet water temperature: 12°C
Total Cooling Capacity kW
Sensible Capacity
kW
Water Flow Rate
l/s
Water Pressure Drop
kPa
32.4 31.1 28.0 47.3 43.4 38.9 66.8 62.0 55.8 78.8 72.2 64.4 91.5 83.3 73.5 94.4 85.4 74.8
30.1 28.9 26.1 39.0 35.5 31.4 56.2 52.1 46.9 64.8 59.4 53.0 73.7 67.1 59.2 74.1 67.0 58.7
1.54 1.48 1.34 2.25 2.07 1.85 3.18 2.96 2.66 3.75 3.44 3.07 4.36 3.97 3.50 4.50 4.07 3.57
49
46
38
64
57
48 116 101 90
92
79
65
62
53
44
60
51
42
Inlet water temperature:10°C - outlet water temperature: 15°C
Total Cooling Capacity kW 23.2 22.3 20.1 29.4 27.2 24.4 41.5 38.5 34.6 50.6 46.4 41.3 62.0 56.2 49.5 65.5 59.3 51.9
Sensible Capacity
kW 23.2 22.3 20.1 29.4 27.2 24.4 41.5 38.5 34.6 50.6 46.4 41.3 60.0 54.4 48.0 60.1 54.4 47.7
Water Flow Rate
l/s 1.11 1.06 0.96 1.40 1.30 1.16 1.98 1.84 1.65 2.41 2.21 1.97 2.96 2.68 2.36 3.13 2.83 2.48
Water Pressure Drop
kPa 35
33
28
29
25
20
53
46
38
47
40
34
26
31
28
28
24
29
FANS SECTION
Quantity
1
2
Type
Single inlet, backward curved, radial centrifugal fan (plug fan)
CHILLED WATER COIL
Quantity
1
2
1
2
Tubes/Fins
Copper tubes / Treated aluminium fins
Coil Surface Area
m2
0.74
1.49
Orientation
Inclined
CHILLED WATER CONNECTIONS
Water Connections
inch
1”
1¼“
1½“
DIMENSIONS
Length
mm
1000
1750
Depth
mm
890
Height
mm
1950
Footprint
m2
0.89
1.56
WEIGHTS
Net
kg
290
490
495
500
550
560
Gross
kg
295
495
500
505
555
565
1
At the following standard conditions: 24°C db; 50% R.H. (17°C wb), Power Supply Voltage 400/3/50, 50Pa ESP (External Static Pressure).
Max available ESP at quoted airflow
3
Measured in front of the unit at 1m height, 2 m distance, in the free field, fan and compressor running, 50Pa ESP.
Note: Quoted capacities are gross capacities, for nett capacities, deduct fan motor kW. Unit air flow is quoted at standard configuration, with a clean EU4 filter.
2
SLE CP TDM E.1 (06/99)
29
Challenger Plus - Technical Data Manual
Condenser matching tables (all models)
Single circuit condensers
Ambient
32oC
35oC
CP20AU/D & CP20DU/D
HCA24
41oC
46oC
49oC
HCA42
HCA42
Challenger Plus (1 condenser per indoor unit)
HCA29
HCA33
CP24AU/D & CP24DU/D
HCA29
HCA33
HCA42
HCA58
HCA58
CP28AU/D & CP28DU/D
HCA42
HCA42
HCA58
HCA74
HCA74
CP34AU/D & CP34DU/D
HCA42
HCA49
HCA74
HCA74
HCA74
CP40AU/D & CP40DU/D
HCA49
HCA74
HCA87
HCA95
HCA95
Challenger Plus (2 condensers per indoor unit)
CP26AU/D & CP26DU/D
HCA17
HCA24
HCA24
HCA29
HCA29
CP32AU/D & CP32DU/D
HCA24
HCA24
HCA29
HCA42
HCA42
CP42AU/D & CP42DU/D
HCA24
HCA29
HCA33
HCA42
HCA42
CP46AU/D & CP46DU/D
HCA29
HCA42
HCA49
HCA58
HCA58
Ambient
32oC
35oC
41oC
46oC
49oC
CP26AU/D & CP26DU/D
HBA33
HBA49
HBA49
HBA74
HBA74
CP32AU/D & CP32DU/D
HBA49
HBA49
HBA74
HBA74
HBA74
CP42AU/D & CP42DU/D
HBA49
HBA74
HBA74
HBA87
HBA87
CP46AU/D & CP46DU/D
HBA74
HBA74
HBA87
Dual circuit condensers
Challenger Plus (1 condensers per indoor unit)
Selections are based on a maximum condensing temperature of 49oC in ambients of 32 to 35 oC, a maximum condensing temperature of 52oC
in ambients of 36 to 41oC, a maximum condensing temperature of 55oC in ambients of 42 to 46oC and a maximum condensing temperature of
58oC in ambients of 47 to 49oC. Indoor unit conditions 24oC/50%RH, standard airflow.
Indoor unit capacity decreases with increasing condensing temperature, consult Liebert Applications Engineers for specific capacity details.
Note : For higher ambient applications, please consult your local Liebert representative.
30
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Chilled Water data - all units
Influence of glycol concentration on the cooling capacity of Challenger Plus units
The presence of glycol mixed with water, as the thermal carrier fluid, reduces the cooling capacity of the unit. This capacity
reduction differs depending on the glycol percentage and the return air temperature.
The average reductions for the Total Capacity and the Sensible Capacity are given in the following charts.
SLE CP TDM E.1 (06/99)
31
Challenger Plus - Technical Data Manual
Electrical data - all models
Fan
400V/3ph/50Hz
Model
CP20A D
CP24A D
CP28A D
CP34A D
CP40A D
CP26A D
CP32A D
CP42A D
CP46A D
CP20A U
CP24A U
CP28A U
CP34A U
CP40A U
CP26A U
CP32A U
CP42A U
CP46A U
CP20D D
CP24D D
CP28D D
CP34D D
CP40D D
CP26D D
CP32D D
CP42D D
CP46D D
CP20D U
CP24D U
CP28D U
CP34D U
CP40D U
CP26D U
CP32D U
CP42D U
CP46D U
OA
FLA
LRA
3.9
4.2
2 x 4.1
2 x 4.1
2 x 4.2
2 x 4.1
2 x 4.1
2 x 4.2
2 x 4.3
4.1
4.3
2 x 4.1
2 x 4.3
2 x 4.4
2 x 4.1
2 x 4.3
2 x 4.4
2 x 4.4
4.1
4.4
2 x 4.2
2 x 4.3
2 x 4.4
2 x 4.2
2 x 4.3
2 x 4.4
2 x 4.4
4.2
4.4
2 x 4.2
2 x 4.3
2 x 4.4
2 x 4.2
2 x 4.3
2 x 4.4
2 x 4.4
4.5
4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
4.8
4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
4.8
4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
4.8
4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
Compressor (R407C)
400V/3ph/50Hz
Power
kW
0.98
1.3
2.2
2.3
2.7
2.2
2.3
2.7
3.0
1.1
1.42
2.4
2.9
3.1
2.4
2.9
3.1
3.4
1.2
1.6
2.5
2.8
3.0
2.45
2.7
3.0
3.5
1.2
1.7
2.6
3.0
3.5
2.6
3.0
3.5
3.9
OA
FLA
LRA
11.1
11.8
14.7
16.2
18.9
2 x 6.5
2 x 8.0
2 x 11.1
2 x 11.8
11.1
11.8
14.7
16.2
18.9
2 x 6.5
2 x 8.0
2 x 11.1
2 x 11.8
11.1
11.8
14.7
16.2
18.9
2 x 6.5
2 x 8.0
2 x 11.1
2 x 11.8
11.1
11.8
14.7
16.2
18.9
2 x 6.5
2 x 8.0
2 x 11.1
2 x 11.8
10.8
15
18.5
21.2
26
2 x 7.5
2 x 9.6
2 x 10.8
2 x 15.0
10.8
15
18.5
21.2
26
2 x 7.5
2 x 9.6
2 x 10.8
2 x 15.0
10.8
15
18.5
21.2
26
2 x 7.5
2 x 9.6
2 x 10.8
2 x 15.0
10.8
15
18.5
21.2
26
2 x 7.5
2 x 9.6
2 x 10.8
2 x 15.0
70.5
94
116
127
159
2 x 51
2 x 59.5
2 x 70.5
2 x 94
70.5
94
116
127
159
2 x 51
2 x 59.5
2 x 70.5
2 x 94
70.5
94
116
127
159
2 x 51
2 x 59.5
2 x 70.5
2 x 94
70.5
94
116
127
159
2 x 51
2 x 59.5
2 x 70.5
2 x 94
Power
kW
4.8
6.4
7.5
8.9
10.9
6.84
8.32
9.6
12.76
4.8
6.4
7.5
8.9
10.9
6.84
8.32
9.6
12.74
4.8
6.4
7.5
8.9
10.9
6.84
8.32
9.6
12.8
4.8
6.4
7.5
8.9
10.9
6.84
8.32
9.6
12.7
OA = Operating Amps, FLA = Full Load Amps, LRA = Locked Rotor Amps.
Fan OA is for standard unit operating at standard ESP.
Compressor OA is quoted at room conditions: 24 deg C, 50% RH; condensing temperature:49 deg C.
Compressor FLA is quoted at maximum evaporating and condensing pressures (manufacturers data).
32
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Electrical data - all models (continued)
Fan
400V/3ph/50Hz
Model
CP20W D
CP24W D
CP28W D
CP34W D
CP40W D
CP26W D
CP32W D
CP42W D
CP46W D
CP20W U
CP24W U
CP28W U
CP34W U
CP40W U
CP26W U
CP32W U
CP42W U
CP46W U
CP20H D
CP24H D
CP28H D
CP34H D
CP40H D
CP26H D
CP32H D
CP42H D
CP46H D
CP20H U
CP24H U
CP28H U
CP34H U
CP40H U
CP26H U
CP32H U
CP42H U
CP46H U
OA
FLA
LRA
3.9
4.2
2 x 4.5
2 x 4.1
2 x 4.2
2 x 4.1
2 x 4.1
2 x 4.2
2 x 4.3
4.1
4.3
2 x 4.1
2 x 4.3
2 x 4.4
2 x 4.1
2 x 4.3
2 x 4.4
2 x 4.4
4.1
4.4
2 x 4.2
2 x 4.3
2 x 4.4
2 x 4.2
2 x 4.2
2 x 4.4
2 x 4.4
4.2
4.4
2 x 4.2
2 x 4.3
2 x 4.4
2 x 4.2
2 x 4.3
2 x 4.4
2 x 4.5
4.8
4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
4.8
4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
4.8
4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
4.8
4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
Compressor (R407C)
400V/3ph/50Hz
Power
kW
0.98
1.3
2.2
2.3
2.7
2.2
2.3
2.7
3.0
1.1
1.4
2.4
2.9
3.1
2.4
2.9
3.1
3.4
1.2
1.6
2.5
2.7
3.0
2.5
2.7
3.0
3.5
1.2
1.7
2.6
3.0
3.5
2.6
3.0
3.5
3.9
OA
FLA
LRA
10.3
10.4
12.8
14.3
16.4
2 x 5.8
2 x 7.2
2 x 10.3
2 x 10.4
10.3
10.4
12.8
14.3
16.4
2 x 5.8
2 x 7.2
2 x 10.3
2 x 10.4
10.3
10.4
12.8
14.3
16.4
2 x 5.8
2 x 7.2
2 x 10.3
2 x 10.4
10.3
10.4
12.8
14.3
16.4
2 x 5.8
2 x 7.3
2 x 10.3
2 x 10.4
10.8
15
18.5
21.2
26
2 x 7.5
2 x 9.6
2 x 10.8
2 x 15.0
10.8
15
18.5
21.2
26
2 x 7.5
2 x 9.6
2 x 10.8
2 x 15.0
10.8
15
18.5
21.2
26
2 x 7.5
2 x 9.6
2 x 10.8
2 x 15.0
10.8
15
18.5
21.2
26
2 x 7.5
2 x 9.6
2 x 10.8
2 x 15.0
70.5
94
116
127
159
2 x 51
2 x 59.5
2 x 70.5
2 x 94
70.5
94
116
127
159
2 x 51
2 x 59.5
2 x 70.5
2 x 94
70.5
94
116
127
159
2 x 51
2 x 59.5
2 x 70.5
2 x 94
70.5
94
116
127
159
2 x 51
2 x 59.5
2 x 70.5
2 x 94
Power
kW
4.0
5.3
6.2
7.3
9.2
5.6
6.92
7.94
10.6
4.0
5.3
6.2
7.3
9.2
5.6
6.9
7.9
10.6
4.0
5.3
6.2
7.3
9.2
5.6
6.9
7.9
10.6
4.0
5.3
6.2
7.3
9.2
5.6
6.9
7.9
10.6
OA = Operating Amps, FLA = Full Load Amps, LRA = Locked Rotor Amps.
Fan OA is for standard unit operating at standard ESP.
Compressor OA is quoted at room conditions: 24oC, 50% RH; condensing temperature: 40.5 oC.
Compressor FLA is quoted at maximum evaporating and condensing pressures (manufacturers data).
SLE CP TDM E.1 (06/99)
33
Challenger Plus - Technical Data Manual
Electrical data - all models (continued)
Fan
400V/3ph/50Hz
Model
CP20F D
CP24F D
CP28F D
CP34F D
CP40F D
CP26F D
CP32F D
CP42F D
CP46F D
CP20F U
CP24F U
CP28F U
CP34F U
CP40F U
CP26F U
CP32F U
CP42F U
CP46F U
OA
FLA
LRA
4.1
4.3
2 x 4.2
2 x 4.3
2 x 4.4
2 x 4.1
2 x 4.3
2 x 4.4
2 x 4.4
4.1
4.4
2 x 4.2
2 x 4.3
2 x 4.4
2 x 4.2
2 x 4.3
2 x 4.4
2 x 4.4
4.8
4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
4.8
4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
Compressor (R407C)
400V/3ph/50Hz
Power
kW
1.2
1.5
2.5
2.7
3.0
2.5
2.7
3.0
3.5
1.2
1.7
2.6
3.0
3.5
2.6
3.0
3.5
3.9
OA
FLA
LRA
11.3
12.7
16.3
17.1
20.3
2 x 6.8
2 x 8.4
2 x 11.3
2 x 13.1
11.3
12.5
16.2
17.1
20.3
2 x 6.8
2 x 8.4
2 x 11.3
2 x 13.0
10.8
15
18.5
21.2
26
2 x 7.5
2 x 9.6
2 x 10.8
2 x 15.0
10.8
15
18.5
21.2
26
2 x 7.5
2 x 9.6
2 x 10.8
2 x 15.0
70.5
94
116
127
159
2 x 51
2 x 59.5
2 x 70.5
2 x 94
70.5
94
116
127
159
2 x 51
2 x 59.5
2 x 70.5
2 x 94
Power
kW
5.0
7.0
8.5
9.8
11.9
7.4
9.1
10.0
14.5
5.0
6.9
8.5
9.7
11.8
7.4
9.0
9.9
14.4
OA = Operating Amps, FLA = Full Load Amps, LRA = Locked Rotor Amps.
Fan OA is for standard unit operating at standard ESP.
Compressor OA is quoted at room conditions: 24oC, 50% RH;
Compressor FLA is quoted at maximum evaporating and condensing pressures (manufacturers data).
34
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Electrical data - all models (continued)
Model
(ESP*)
CP25C D 150Pa
CP25C D 250Pa
CP25C D 350Pa
CP35C D 150Pa
CP35C D 250Pa
CP35C D 350Pa
CP50C D 150Pa
CP50C D 250Pa
CP50C D 350Pa
CP60C D 150Pa
CP60C D 250Pa
CP60C D 350Pa
CP70C D 150Pa
CP70C D 250Pa
CP70C D 350Pa
CP75C D 150Pa
CP75C D 250Pa
CP75C D 350Pa
CP25C U 150Pa
CP25C U 250Pa
CP25C U 350Pa
CP35C U 150Pa
CP35C U 250Pa
CP35C U 350Pa
CP50C U 150Pa
CP50C U 250Pa
CP50C U 350Pa
CP60C U 150Pa
CP60C U 250Pa
CP60C U 350Pa
CP70C U 150Pa
CP70C U 250Pa
CP70C U 350Pa
CP75C U 150Pa
CP75C U 250Pa
CP75C U 350Pa
FAN
400V/3ph/50Hz
OA
FLA
LRA
4.5
4.4
4.3
4.4
4.4
4.3
9.0
8.9
8.7
9.0
8.9
8.7
9.0
8.9
8.7
9.0
8.9
8.6
4.5
4.4
4.3
4.4
4.5
4.4
8.8
8.9
8.7
8.8
8.9
8.7
8.8
8.9
8.7
8.7
8.8
8.6
4.8
4.8
4.8
4.8
4.8
4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
4.5
4.5
4.5
4.5
4.5
4.5
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
2 x 4.8
17.5
17.5
17.5
17.5
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
17.5
17.5
17.5
17.5
17.5
17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
2 x 17.5
Nominal Power
kW
2.0
1.7
1.4
2.1
1.8
1.4
4.2
3.5
2.9
4.2
3.5
5.9
4.2
3.5
5.9
4.2
3.5
5.9
2.1
1.9
1.5
2.2
1.9
1.5
4.4
3.8
3.0
4.4
3.8
3.0
4.4
3.8
3.0
4.3
3.8
3.0
OA = Operating Amps, FLA = Full Load Amps, LRA = Locked Rotor Amps.
*: ESP = External Static Pressure
SLE CP TDM E.1 (06/99)
35
Challenger Plus - Technical Data Manual
Electrical data - all models (continued)
MODEL
COMPONENT
NOMINAL POWER (kW)
(400/3/50)
FLA
5.85
8.5
7.3
15.5
5.85
8.5
7.3
15.5
11.7
17
7.3
15.5
11.7
17
7.3
15.5
Models
CP20A/W/F/D/H
CP24A/W/F/D/H
CP25C
CP35C
Upflow & Downflow
All other Models
3 steps, Total Capacity (kW)
5.85
11.7
2 steps (kW)
3.9
7.8
1 step (kW)
1.95
3.9
Electric Heating
CP20A/W/F/D/H
CP24A/W/F/D/H
Upflow & Downflow
Humidifier
Electric Heating
CP25C
CP35C
Upflow & Downflow
Humidifier
CP26A/W/F/D/H
CP28A/W/F/D/H
CP32A/W/F/D/H
CP34A/W/F/D/H
CP40A/W/F/D/H
CP42A/W/F/D/H
CP46A/W/F/D/H
Upflow & Downflow
CP50C
CP60C
CP70C
CP75C
Upflow & Downflow
Electric Heating
Humidifier
Electric Heating
Humidifier
Electrical heating data is quoted for maximum heating capacity (3 steps).
Electric reheat stages
Capacity (400V/3ph/50Hz)
36
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Sound data - all models
OCTAVE BAND FREQUENCY (Hz) - DOWNFLOW MODELS
Model
CP20
A/W
CP24
A/W
CP26/28
A/W
CP32/34
A/W
CP40/42
A/W
CP46
A/W
CP20
F/D/H
CP24
F/D/H
CP26/28
F/D/H
CP32/34
F/D/H
CP40/42
F/D/H
CP46
A/W
CP25C
CP35C
CP50C
CP60C
CP70C
CP75C
Mode
Level
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(4)
(1)
(4)
(1)
(4)
(1)
(4)
(1)
(4)
(1)
(4)
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
PWL
SPL
PWL
SPL
PWL
SPL
PWL
SPL
PWL
SPL
PWL
SLE CP TDM E.1 (06/99)
31.5
63
125
250
500
1000
2000
4000
8000
57.3
58.0
70.1
59.1
59.8
72.2
55.6
56.3
69.5
56.7
57.4
71.1
57.8
58.5
73.7
59.8
60.5
75.7
56.0
56.7
68.4
58.7
59.4
71.0
54.4
55.1
69.0
55.6
56.3
70.8
57.0
57.7
72.8
58.5
59.2
74.3
60.9
72.0
59.1
70.3
59.2
72.6
58.7
71.9
56.8
71.7
56.4
71.2
57.3
58.0
70.1
59.1
59.8
72.2
55.6
56.3
69.5
56.7
57.4
71.1
57.8
58.0
73.7
59.8
60.5
75.7
56.0
56.7
68.4
58.7
59.4
71.0
54.4
55.1
69.0
55.6
56.3
70.8
57.0
57.7
72.8
58.5
59.2
74.3
60.9
72.0
59.1
70.3
59.2
72.6
58.7
71.9
56.8
71.7
56.4
71.2
61.1
61.4
79.0
65.5
65.5
83.1
64.3
64.6
81.7
65.9
66.2
83.5
67.6
67.9
85.6
68.7
69.0
86.7
62.2
62.5
80.3
65.3
65.6
83.2
64.1
64.4
83.7
66.3
66.6
84.8
66.9
67.2
85.6
68.1
68.4
86.8
66.3
83.3
65.0
82.6
70.0
85.4
69.8
85.2
66.8
85.1
66.7
85.0
54.7
54.9
75.1
57
57.2
77.5
59.1
59.3
76.7
59.9
60.1
77.8
61.0
61.2
79.8
62.9
63.1
81.7
54.2
54.4
74.9
58.2
58.4
78.3
58.2
58.4
77.1
59.5
59.0
78.4
61.1
61.4
80.3
63.3
63.5
82.4
58.6
78.0
57.1
77.0
62.8
79.8
62.5
79.3
60.7
79.2
60.5
78.9
45
45.1
70.9
48.4
48.5
74.3
53.0
53.1
73.0
54.2
54.3
74.4
55.8
55.9
76.0
57.6
57.7
78.5
45.1
45.2
71.4
49.4
49.5
75.1
52.4
52.5
74.1
54.3
54.4
75.5
55.8
55.9
77.2
57.9
58.0
79.3
48.9
74.8
47.4
73.9
55.5
76.7
55.2
76.3
54.4
76.2
54.3
76.0
42.1
42.5
69.8
45.2
45.6
53.0
48.9
49.3
71.5
50.1
50.5
73.0
51.5
51.9
75.2
53.6
54.0
77.3
42.2
42.6
70.0
46.7
47.1
73.9
48.2
48.6
72.4
50.0
50.4
73.9
51.7
52.1
75.8
54.2
54.6
78.3
46.9
73.5
45.4
72.5
52.3
75.3
52.1
74.9
51.3
74.7
51.5
74.5
40.4
41.0
63.4
43.8
44.4
66.7
45.7
46.3
65.6
46.8
47.4
66.9
48.4
49.0
69.2
50.6
51.2
71.4
40.6
41.2
63.9
45.8
46.4
68.3
45.1
45.7
66.8
47.1
47.7
68.2
48.9
49.5
70.2
51.5
52.1
72.8
45.5
67.6
44.1
66.7
49.0
69.5
48.8
69.1
48.3
69.0
48.1
68.8
30.9
31.2
55.5
35.1
35.4
59.4
37.2
37.5
58.0
38.5
38.8
59.5
40.6
41.2
62.0
42.9
43.5
64.3
31.6
31.9
56.4
37.9
38.2
61.6
36.8
37.1
59.8
39.4
39.7
61.4
41.4
41.7
63.5
43.9
44.2
66.0
36.9
60.5
35.6
59.7
41.3
62.6
41.2
62.3
40.7
62.2
40.6
62.1
18.9
20.7
45.1
22.8
24.6
48.8
22.7
24.5
48.7
23.7
25.5
49.7
25.7
27.5
51.7
27.9
29.7
53.9
19.7
21.5
46.5
26.5
28.3
51.9
22.3
24.1
50.4
24.8
26.6
51.8
27.0
28.8
53.9
29.6
31.4
56.5
24.5
50.1
23.4
49.7
28.3
52.9
28.3
52.7
26.1
52.7
26.1
52.7
Sound
Pressure
Levels
dB (A)
50.8
51.1
74.0
54.2
54.4
77.2
56.1
56.4
76.0
57.3
57.5
77.4
58.7
59.0
79.6
60.5
60.8
81.5
51.0
51.3
74.4
55.1
55.4
78.2
55.5
55.8
77.0
57.3
57.6
78.4
58.7
59.1
80.2
60.9
61.2
82.4
55.4
77.8
54.0
76.8
59.9
79.6
59.6
79.3
58.1
79.1
58.1
78.9
37
Challenger Plus - Technical Data Manual
Sound data - all models (continued)
OCTAVE BAND FREQUENCY (Hz) - UPFLOW MODELS
Model
CP20
A/W
CP24
A/W
CP26/28
A/W
CP32/34
A/W
CP40/42
A/W
CP46
A/W
CP20
F/D/H
CP24
F/D/H
CP26/28
F/D/H
CP32/34
F/D/H
CP40/42
F/D/H
CP46
F/D/H
CP25C
CP35C
CP50C
CP60C
CP70C
CP75C
38
Mode
Levels
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(2)
(3)
(1)
(4)
(1)
(4)
(1)
(4)
(1)
(4)
(1)
(4)
(1)
(4)
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
SPL
PWL
SPL
PWL
SPL
PWL
SPL
PWL
SPL
PWL
SPL
PWL
SPL
PWL
31.5
63
125
250
500
1000
2000
4000
8000
57.8
58.6
69.4
61.0
60.2
72.5
55.1
55.9
68.9
56.7
57.5
70.9
57.0
57.8
72.5
59.5
60.3
74.7
56.4
57.2
68.3
58.9
59.7
71.0
54.2
55.0
69.1
54.8
55.6
70.8
57.0
57.8
72.5
58.0
58.8
73.5
63.8
73.8
60.2
71.0
57.9
71.8
57.6
71.5
56.6
71.3
56.1
70.9
57.8
58.6
69.4
61.0
60.2
72.5
55.1
55.9
68.9
56.7
57.5
70.9
57.0
57.8
72.5
59.5
60.3
74.7
56.4
57.2
68.3
58.9
59.7
71.0
54.2
55.0
69.1
54.8
55.6
70.8
57.0
57.8
72.5
58.0
58.8
73.5
63.8
73.8
60.2
71.0
57.9
71.8
57.6
71.5
56.6
71.3
56.1
70.9
55.5
56.2
80.4
60.2
59.5
83.5
62.8
63.5
83.1
64.6
65.3
84.9
64.6
65.3
86.1
66.0
66.7
86.8
57.1
57.8
81.4
59.3
60.0
83.4
63.2
63.9
84.3
63.4
64.1
84.9
64.6
65.3
86.1
65.6
66.3
87.1
61.2
84.2
59.2
83.1
65.1
85.2
65.0
85.2
64.0
85.1
63.8
84.9
56.4
56.7
75.3
59.3
59.0
78.3
57.7
58.0
76.9
59.5
59.8
78.9
61.0
61.3
81.5
62.5
62.8
82.4
56.0
56.3
75.2
59.9
60.2
78.8
57.3
57.6
77.5
57.6
57.9
79.1
61.0
61.3
81.5
62.8
63.1
83.3
61.8
79.5
59.4
78.0
60.6
79.7
60.4
79.6
5.4
79.5
59.2
79.3
48.1
48.6
71.6
52.0
51.5
75.0
54.3
54.8
73.8
56.6
57.1
76.1
57.8
58.3
78.5
59.3
59.8
79.3
48.8
49.3
72.0
52.7
53.2
75.7
54.4
54.9
74.8
54.7
55.2
76.3
57.8
58.3
78.5
59.6
60.1
80.3
54.2
76.2
50.9
74.9
56.6
76.8
56.4
76.7
55.4
76.6
55.2
76.5
46.2
46.7
70.3
50.0
49.5
73.8
51.5
52.0
72.1
53.8
54.3
74.5
55.5
56.0
77.4
56.9
57.4
78.2
46.4
46.9
70.5
51.0
51.5
74.5
51.5
52.0
73.1
51.7
52.2
74.8
55.5
56.0
77.4
57.4
57.9
79.3
52.5
75.1
50.1
73.6
54.9
75.4
54.7
75.3
53.7
75.2
53.5
75.0
42.1
42.5
64.1
46.1
45.7
67.8
49.1
49.5
66.4
51.5
51.9
68.9
53.6
54.0
72.1
54.7
55.1
72.7
42.8
43.2
64.5
47.8
448.2
69.1
49.3
49.7
67.6
49.4
49.8
69.2
53.6
54.0
72.1
55.5
55.9
74.0
48.9
69.3
46.6
67.9
52.6
69.8
52.5
69.8
51.5
69.6
51.3
69.5
32.4
32.9
56.5
37.2
36.7
60.7
43.6
44.1
59.3
46.6
47.1
62.4
48.9
49.4
65.6
49.9
50.4
65.9
33.8
34.3
57.3
39.5
40.0
62.4
44.2
44.7
61.0
44.3
44.8
62.9
48.9
49.4
65.6
50.8
51.3
67.5
39.9
62.3
37.8
61.1
47.8
63.3
47.7
63.4
46.7
63.2
46.6
63.2
22.3
22.8
46.4
26.6
26.1
50.2
30.9
31.4
50.0
34.1
34.6
53.1
36.8
37.3
56.6
37.3
37.8
56.2
23.6
24.1
47.4
29.8
30.3
52.8
31.6
32.1
51.7
31.6
32.1
53.9
36.8
37.3
56.6
38.8
39.3
58.6
28.7
51.7
27.4
51.3
35.3
54.1
35.3
54.3
34.3
54.2
34.3
54.3
Sound
Pressure
Levels
dB(A)
52.2
52.7
74.6
55.8
55.4
78.0
57.3
57.8
76.7
59.5
60.0
79.0
61.1
61.6
81.6
62.5
62.9
82.4
52.5
52.9
74.9
56.7
57.1
78.7
57.4
57.8
77.7
57.6
58.1
79.2
61.1
61.6
81.6
62.9
63.4
83.4
58.2
79.3
55.7
77.9
60.3
79.7
60.2
79.7
59.2
79.5
59.0
79.4
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Technical Data - optional components
Hot gas reheat for models A/W/F/D/H
Models
No. of Rows
2
Surface Area m
Capacity kW*
CP20
CP24
CP26
CP28
CP32
CP34
CP40
CP42
CP46
2
2
1
1
1
1
1
1
1
0.432
0.432
0.882
0.882
0.882
0.882
0.882
0.882
0.882
11.4
14.1
10
17.1
12
20.0
24.8
11.4
14.1
0
0
* Quoted at room conditions: 24 C, 50% rH, condensing temperature 45 C.
Hot water reheat performance (DX Units)
Downflow Models
CP20
CP24
CP26
CP28
CP32
A/W/F/D/H
No. of Rows
2
Surface Area m2
0.432
Ambient temp. 24°C, 50% R.H., water inlet/outlet temperature 80/65°C
Capacity
kW
16.3
17.7
24.2
24.2
25.2
Water Flow Rate
l/s
0.26
0.26
0.39
0.39
0.41
Coil Pressure
kPa
2
2
4
4
4
Drop
Total Pressure
kPa
3
3
7
7
7
Drop
Ambient temp. 20°C, 50% R.H., water inlet/outlet temperature 80/65°C
Capacity
kW
18.2
19.8
26.5
26.5
27.6
Water Flow Rate
l/s
0.30
0.32
0.43
0.43
0.45
Coil Pressure
kPa
2
2
4
4
5
Drop
Total Pressure
kPa
4
4
8
8
8
Drop
SLE CP TDM E.1 (06/99)
CP34
1
0.882
CP40
CP42
CP46
25.2
0.41
26.1
0.43
26.1
0.43
26.5
0.45
4
4
4
4
7
7
7
7
27.6
0.45
28.6
0.47
28.6
0.47
29
0.49
5
5
5
5
8
8
8
8
39
Challenger Plus - Technical Data Manual
Technical Data - optional components (continued)
Hot water reheat performance (DX Units)
Upflow Models
CP20
CP24
CP26
CP28
CP32
A/W/F/D/H
No. of Rows
2
Surface Area m2
0.432
Ambient temp. 24°C, 50% R.H., water inlet/outlet temperature 80/65°C
Capacity
kW
16.3
18.0
23.9
23.9
24.9
Water Flow Rate
l/s
0.27
0.29
0.39
0.39
0.41
Coil Pressure
kPa
2
2
4
4
4
Drop
Total Pressure
kPa
3
4
6
6
7
Drop
Ambient temp. 20°C, 50% R.H., water inlet/outlet temperature 80/65°C
Capacity
kW
18.3
20.4
26.2
26.2
27.3
Water Flow Rate
l/s
0.30
0.33
0.43
0.43
0.44
Coil Pressure
kPa
2
2
4
4
4
Drop
Total Pressure
kPa
4
5
7
7
8
Drop
CP34
1
0.882
CP40
CP42
CP46
24.9
0.41
26.2
0.43
26.2
0.43
26.5
0.45
4
4
4
4
7
7
7
1
27.3
0.44
28.7
0.47
28.7
0.47
29
0.49
4
5
5
5
8
9
9
9
Hot water reheat performance (Chilled Water Units)
Downflow
CP25C
CP35C
CP50C
CP60C
CP70C
CP75C
Models
Max. ESP (Pa)
150 250 350 150 250 350 150 250 350 150 250 350 150 250 350 150 250 350
Flow Rate (m3/s)
2.2222.0001.7782.1971.9751.7174.1763.7503.2784.1113.6943.1944.0393.6223.1443.9443.5333.067
No. of Rows
2
1
2
Surface Area m
0.432
0.882
Ambient temp. 24°C, 50% R.H., water inlet/outlet temperature 80/65°C
Capacity
kW
21.2 19.9 18.5 21.6 19.7 18.1 30.4 28.6 26.5 30.1 28.4 26.1 29.8 28.1 25.9 29.4 27.7 25.6
Water Flow Rate
l/s
0.35 0.33 0.30 0.34 0.32 0.29 0.50 0.47 0.43 0.49 0.46 0.43 0.49 0.46 0.42 0.48 0.45 0.42
Coil Pressure Drop
kPa
2
2
2
2
2
2
5
5
4
5
5
4
5
5
4
5
5
4
Total Pressure Drop
kPa
5
4
4
5
4
4
10
9
8
9
9
7
9
8
7
9
8
7
Ambient temp. 20°C, 50% R.H., water inlet/outlet temperature 80/65°C
Capacity
kW
23.6 22.2 20.6 23.4 22.0 20.1 33.6 34.1 29.3 33.1 31.1 28.7 32.7 30.1 28.4 32.3 30.3 28.1
Water Flow Rate
l/s
0.39 0.36 0.34 0.38 0.36 0.33 0.54 0.51 0.47 0.54 0.51 0.47 0.53 0.50 0.46 0.53 0.50 0.46
Coil Pressure Drop
kPa
3
2
2
3
2
2
6
6
5
6
5
5
6
5
5
6
5
5
Total Pressure Drop
kPa
6
5
5
6
5
5
11 10
9
11 10
9
11 10
9
11
9
8
40
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Technical Data - optional components (continued)
Hot water reheat performance (Chilled Water Units)
Upflow
CP25C
CP35C
CP50C
CP60C
CP70C
CP75C
Models
Max ESP (Pa)
150 250 350 150 250 350 150 250 350 150 250 350 150 250 350 150 250 350
Flow Rate (m3/s)
2.3612.233 1.95 2.25 2.0251.7614.0063.5943.117 3.9 3.4943.033 3.9 3.4943.033 3.71 3.3222.878
No. of Rows
2
1
Surface Area m2
0.432
0.882
Ambient temp. 24°C, 50% R.H., water inlet/outlet temperature 80/65°C
Capacity
kW
22.0 21.2 19.5 21.3 20.0 18.3 29.7 27.9 25.8 29.3 27.5 25.4 29.3 27.5 25.4 28.5 26.7 24.6
Water Flow Rate
l/s
0.36 0.35 0.32 0.35 0.33 0.30 0.48 0.46 0.42 0.48 0.45 0.41 0.48 0.45 0.41 0.46 0.44 0.40
Coil Pressure Drop
kPa
2
2
2
2
2
2
5
5
4
5
5
4
5
5
4
5
5
4
Total Pressure Drop
kPa
5
5
4
5
4
4
9
8
7
9
8
7
9
8
7
8
8
7
Ambient temp. 20°C, 50% R.H., water inlet/outlet temperature 80/65°C
Capacity
kW
24.5 23.7 21.8 23.8 22.3 20.5 32.5 30.6 28.3 32.1 30.1 27.8 32.1 30.1 27.8 31.2 29.3 27.1
Water Flow Rate
l/s
0.40 0.39 0.36 0.39 0.36 0.33 0.53 0.50 0.46 0.52 0.49 0.45 0.52 0.49 0.45 0.51 0.48 0.44
Coil Pressure Drop
kPa
3
3
2
3
2
2
6
5
5
6
5
5
6
5
5
5
5
4
Total Pressure Drop
kPa
6
6
5
6
5
5
11 10
8
10
9
8
10
9
8
10
9
8
Additional pressure drops due to reheat coils
The pressure drops shown in the graphs below must be deducted from the available heads.
HOT WATER AND HOT GAS REHEAT COILS FOR MODELS CP20/CP24A/W/F/D/H & CP25/35C
SLE CP TDM E.1 (06/99)
41
Challenger Plus - Technical Data Manual
Technical Data - optional components (continued)
Additional pressure drops due to reheat coils
The pressure drops shown in the graphs below must be deducted from the available heads.
HOT WATER AND HOT GAS REHEAT COILS FOR MODELS CP 26 TO CP46A/W/F/D/H & CP50 TO CP75C
Humidifier
Power Supply
400 VY/3 ph/50- Hz
Adjustment
Range [kg/h]
2.7-9.0
Rated current
[A]
10.3
Rated power
[KW]
7.3
Refrigerant non-return valves (models A and D)
MODELS
MAX. RECOMMENDED REFRIGERANT CHARGE
WITHOUT NON-RETURN VALVE (kg)
CP20 A/D
4.5
CP24 to CP40 A/D
10
CP26 A/D (*)
4.5
CP32 A/D (*)
4.5
CP42 A/D (*)
4.5
CP46 A/D (*)
10
(*) Denotes models with dual refrigeration circuit
42
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Technical Data - optional components (continued)
High efficiency filters EU5
Eurovent 4/5 Class
(CEN Filter Class CEN EN 779)
Filter quantity per unit
CP20/CP24 A/W/F/D/H
CP 25/CP35C
Filter quantity per unit
All other models
Height (mm)
EU5
(G5)
2
4
100
Additional Pressure Drop: EU4 Filters Substituted By EU5 Filters
The pressure drops shown in the tables below must be deducted from the available ESP.
Models CP20/CP24A/W/F/D/H & CP25C/CP35C
All other Models
SLE CP TDM E.1 (06/99)
43
Challenger Plus - Technical Data Manual
Technical Data - optional components (continued)
High efficiency filters EU6, EU7 and EU8
Eurovent 4/5 Class
(CEN Filter Class CEN EN 779)
EU6
(G6)
EU7
(G7)
EU8
(G8)
Filter quantity per unit
CP20/CP24 A/W/F/D/H
CP 25/CP35C
1+1
1+1
1+1
Filter quantity per unit
All other models
2+1
2+1
2+1
Height (mm)
290
290
290
Additional Pressure Drop: EU4 Filters Substituted By EU6/EU7/EU8 Filters
The pressure drops shown in the tables below must be deducted from the available ESP.
Models CP20/CP24A/W/F/D/H & CP25C/CP35C
All other Models
44
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Technical Data - optional components (continued)
Filter holding duct (for models with 290mm filters)
CP20/CP24 A/W/F/D/H
CP25/CP35C
All other Models
Length (mm)
1000
1750
Depth (mm)
890
890
Height (mm)
600
600
Models
Base Modules
Width
(mm)
Depth
(mm)
Height
(mm)
CP20/CP24 A/W/F/D/H
CP25/CP35C
990
885
200
All other Models
1740
885
200
Models
Sound Attenuating Cartridges
Models
CP20/CP24 A/W/F/D/H
CP25/CP35C
All other Models
Row no.
1
2
Dimensions
[mm]
Free section
[mm]
500 x 195 x 500
400 x 100
4
8
500 x 195 x 500
400 x 100
9
18
63
1
1
Row no.
1
2
SLE CP TDM E.1 (06/99)
125
4
6
0.2
1
3
Number of cartridges
1 row
2 rows
Attenuation in dB at octave band frequencies (Hz)
250
500
1000
2000
7
15
26
28
12
27
49
53
4000
27
49
Pressure drops (Pa) for each module at different air flows (m3/s)
0.3
0.4
0.5
2
4
7
6
11
18
8000
14
23
0.6
9
26
45
Challenger Plus - Technical Data Manual
Technical Data - optional components (continued)
Combination of accessories
46
SLE CP TDM E.1 (06/99)
Challenger Plus - Technical Data Manual
Dimensional Data - all models
SLE CP TDM E.1 (06/99)
47
Liebert
European Headquarters
Liebert
Globe Park, Marlow,
Buckinghamshire, SL7 1YG, England.
Tel: 44-1628-403200
Fax: 44-1628-403203
International Headquarters
Liebert Corporation
1050 Dearborn Drive, P.O. Box 29186
Columbus, Ohio 43229 USA
Tel: 1-614-888-0246
While every precaution has been taken to ensure accuracy and completeness in this manual, Liebert
assumes no responsibility and disclaims all liability for damages resulting from the use of the
information contained herein or any errors or omissions.
© Liebert
® All rights reserved throughout the world. Specifications
subject to change without notice. Liebert and the logo, are
registered trademarks of Liebert Corporation.
Printed in England.
LPN: SLE CP TDM E.1
HPN: 272030 (17/6/99)

Similar documents