LIEBERT CHALLENGER 3000 AIR
Transcription
LIEBERT CHALLENGER 3000 AIR
Liebert Products & Service World Headquarters United States 1050 Dearborn Drive, P.O. Box 29186 Columbus, Ohio 43229 Telephone: 614-888-0246 Facsimile: 614-841-6973 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco Italy Telephone: 39-049-9719-111 Facsimile: 39-049-5841-257 Asia 29/F, The Orient Square Building F. Ortigas Jr. Road, Ortigas Center Pasig City 1605 Philippines Telephone: 63 2 687 6615 Facsimile: 63 2 730 9572 LIEBERT CHALLENGER 3000 AIR-COOLED SYSTEM PG1 Job Name T-MOBILE - OFCI - DENVER, CO - AIR Model Quantity Date Invoice # Purchaser P.O. # Tag # Submitted By BU042ADADEI / MCS028E7AD 3 (Three) / 3 (Three) December 8, 2014 SWSG 114-068-H01-LIE-P2 Liebert Capitol Office – Jim Grant Rev 10/10 LIEBERT CHALLENGER ENGINEERING SPECIFICATION SHEET Air-Cooled Systems Project Name: Date: Reference No.: Submitted By: T-MOBILE - OFCI - DENVER, CO - AIR December 8, 2014 Q02212338 Liebert Capitol Office – Jim Grant Model Number: BU042ADADEI Quantity: 3 Condenser Model Number: MCS028E7AD Quantity: 3 ELECTRICAL SUPPLY REQUIREMENTS Liebert Room Unit: 460 Volts, 3 Phase, 60 Hertz, 19.8 Full Load Amps, 24.4 Wire Sizing Amps, 25.0 Over-Current Protection Device, 65,000 Amps Short Circuit Current Rating (SCCR) Air-Cooled Condenser: 460 Volts, 3 Phase, 60 Hertz, 1.4 Full Load Amps, 1.8 Wire Sizing Amps, 15.0 Over-Current Protection Device Liebert Lee-Temp Heater: 120 Volts, 1 Phase, 60 Hertz, 1.4 Full Load Amps, 1.8 Wire Sizing Amps, 15.0 Over-Current Protection Device CABINET SECTION · Upflow Unit · Front Return · Unit Color: Main: Z-0420 (IBM Charcoal) NET CAPACITY DATA · 75ºF (23.9ºC) DB – 61.1ºF (16.1ºC) WB · 45% RH · Total Capacity: 40,600 BTU/hr (11.9 kW) · Sensible Capacity: 35,300 BTU/hr (10.3 kW) EVAPORATOR FAN SECTION · Fan Motor: 0.75 HP (0.56 kW) · High Efficiency Motor · Air Volume: 1,800 CFM (3,060 CMH) · External Static Pressure: 0.3 Inches of Water (74.7 Pa) COMPRESSOR SECTION · One Digital Scroll Compressor with Unloading Solenoid Valve, R-407C Refrigerant · Crankcase Heater HUMIDIFIER SECTION · Infrared with Autoflush Humidification – Capacity: 11.0 lbs/hr (5.0 kg/hr) / 4.8 kW REHEAT SECTION · Electric Reheat – Capacity: 33,400 BTU/hr ( 9 kW) (Includes Fan Motor) · Number of Stages: 2 EVAPORATIVE COIL · Coil Face Area: 6.67 sq. ft. (0.62 sq. m.) · Rows of Coil: 3 FILTER SECTION (Disposable Type - Efficiency based on ASHRAE 52.2) · Size: 28.5 in.(724 mm) X 29.5 in.(749mm) · 4" MERV 8 Filter · Extra Filter Sets; Quantity: 1 (One) MICROPROCESSOR CONTROLER · Liebert iCOM microprocessor with Large Graphic Display · Display Language is English MC CONDENSER SECTION · Design Ambient: 95ºF (35ºC) · Platform Size: Small · Control Fan Type: Premium Control & EC Fan · Liebert Lee-Temp Receiver and Head Pressure Control · Domestic Packaging PG2 Rev 10/10 · · · Non-Coated Coil 18” High Aluminum Legs Standard Sound Level UNIT WEIGHT · Module: 615 lbs (279 kg) · Condenser (Net): 154 lbs (70 kg) ADDITIONAL EQUIPMENT · Dual Float Condensate Pump · Locking Disconnect Switch · Reheat and Humidifier Lockout · IS-UNITY-DP, Intellislot Dual Protocol Card; Quantity: 1 (One) Unit · Smoke Sensor · Remote Shutdown Terminals · Common Alarm Contacts · 9” (228 mm) High Floorstand · LT410, Point Leak Sensor; Quantity: 1 (One) Per Unit · Damper Motor Control Circuit. Quantity: 1 (One) Per Unit · 1 (One) Year Limited Labor Warranty · 2 (Two) Years Parts Only Warranty · 2 (Two) Years Compressor Warranty PG3 Rev 10/10 LIEBERT BLOWER SELECTION PROGRAM Page 1 of 1 Liebert Corporation 1050 Dearborn Drive, P.O. Box 29186 Columbus, OH 43229 USA Blower Selection Program Version 3.0 12/8/2014 Sales Person: Sales Office: Office Address: Office Phone Number: Project: Project Location: Unit Type System Type System Hertz Description Model ACFM SCFM Motor Efficiency Main Filter Pre-Filter Reheat Air Return Air Supply Plenum OK Unit System: English Upflow, Challenger Air Cooled 60 BU - DX Cooling 042A Standard : 1800 1800 Standard Merv 8 Std. - 4 inch (102 mm) None Electric Front Top None Blower Model Number of Fans Operating HP Motor HP RPM Static Efficiency TSP, in. H20 ESP, in. H20 A12-9AT 1 0.49 0.75 752 0.46 0.79 0.30 ASHRAE 127-2007 ___ Fan Curve _ _ Operating hp OK Save A Copy Copyright © 2014 Liebert Corporation. A division of Emerson Notice and Conditions | Contacts http://applications.liebert.com/BlowerWeb/frmBlower.asp 12/8/2014 AIR COOLED LIEBERT CHALLENGER 3000 MODELS STANDARD FEATURES 65,000 AMP SHORT CIRCUIT CURRENT RATING (SCCR) The 60Hz electrical panel provides 65kA SCCR. Certain features or combinations of features may reduce the rating; contact factory for limitations. COMPRESSOR WITH HOT GAS BYPASS Scroll with a suction gas cooled motor, internal centrifugal oil pump, vibration isolating mountings, internal thermal overloads, manual reset high pressure switch, and operates at 3500 RPM @ 60 HZ and 2900 RPM @ 50 HZ. Factory piped hot gas solenoid valve and externally equalized regulating valve in the refrigerant circuit. REFRIGERATION SYSTEM Single refrigeration circuit, includes a liquid line filter drier, refrigerant sight glass with moisture indicator, adjustable externally equalized expansion valve, and liquid line solenoid valve. COOLING COIL A-frame/V-frame coil design is constructed of copper tubes and aluminum fins. A stainless steel drain pan is provided. FAN Centrifugal type, double width, double inlet, with lifetime lubricating self aligning ball bearings rated at a minimum life of 100,000 hours. The motor operates at 1750 RPM for 60 HZ and 1450 RPM for 50 HZ. The drive package is variable speed, sized for 200% of the fan motor horsepower (the motor is on an adjustable base). The fan draws air through the coil. The fan assembly is located on an isolated fan deck. FILTER shall be deep pleated 2” ASHRAE 52.2 MERV 8 rating (40% ASHRAE 52.1) located within the cabinet, and accessible from the front of the unit. CABINET AND FRAME Custom powder painted steel panels with 1” (25.4mm), 1 1/2 lbs. (.68kg) insulation. A hinged control access panel opens to a second front panel which is a protection enclosure for high voltage components. The frame corner posts are constructed of 14 gauge MIG welded steel. The frame is painted with a powder coat finish to protect against corrosion. The unit is totally front accessible including any component removal. HUMIDIFIER High intensity infrared quartz lamps over a stainless steel humidifier pan. An automatic water supply system maintains water level in the pan and a timed flush system greatly reduces mineral precipitation, and is field adjustable to change the cycle time. ELECTRIC REHEAT Electric low watt density 304 stainless steel fin tubular electric reheat elements provide two stages of reheat to control room dry bulb temperature. DPN000347 REV 01/12 REV 3 AIR COOLED LIEBERT CHALLENGER 3000 MODELS OPTIONAL FEATURES (Refer to specification sheet for options supplied) DIGITAL COMPRESSOR Scroll with a suction gas cooled motor, internal centrifugal oil pump, vibration isolating mountings, internal thermal overloads, manual reset high pressure switch, unloading solenoid valve and piping and operates at 3500 RPM @ 60 Hz and 2900 RPM @ 50 Hz. CONDENSATE PUMP Has a minimum capacity of 100 GPH (379 l/h) at 20 ft. head (58 kPa). (Consult factory for 200V or 230V, 50Hz applications). Pump is complete with integral primary and secondary float switches, pump, motor assembly, and reservoir. (Shipped loose for field installation on Downflow (BF) Units). UNIT DISCONNECT SWITCH For 60Hz units: A “Locking-Type” fused disconnect switch is available. For 50Hz units: Two types of non-fused disconnect switches are available, the “Locking-Type” and a “Non-Locking Type”. The “Non-Locking Type” consists of a main unit switch operational from the outside of the unit. Access to the high voltage electric panel compartment can be obtained with the switch in either the “on” or “off” position. The “Locking-Type” is similar except access to the high voltage electric panel compartment can be obtained only with the switch in the “off” position. FIRESTAT Is mounted in the unit with the sensing element in the return air flow. Upon activation the high temperature stat will immediately shut down the entire unit. SMOKE DETECTOR The smoke detector senses the return air, shuts down the unit upon detection, and sends visual and audible alarm. Dry contacts are available for a remote customer alarm. This smoke detector is not intended to function as or replace any room smoke detection system that may be required by local or national codes. FILTERS The standard and optional filters are available with optional pre-filters. A 2” ASHRAE 52.2 MERV 8 (40% ASHRAE 52.1) prefilter, and 4” ASHRAE 52.2 MERV 8 (40% ASHRAE 52.1) or 4” ASHRAE 52.2 MERV 11 (60-65% ASHRAE 52.1) main filter may be specified. LIQUI-TECT SENSOR Is a solid state water sensor that has no moving parts and is hermetically sealed to keep out dust and dirt. When the sensor detects the presence of moisture the alarm system is activated. REMOTE TEMPERATURE AND HUMIDITY SENSORS Are provided in a vented case for mounting in the room to be conditioned. Includes 30 ft. (9m), 60 ft. (18m), 90 ft. (27m), 120 ft. (36m), or 150 ft. (45m) of cable supplied for connecting sensors to unit. FLOOR STAND Is constructed of MIG welded tubular steel and available in heights from 9” to 24” (229mm to 610mm) with vibration isolation pads provided on the adjustable legs. An optional factory supplied turning vane is available for field installation if desired. PLENUM(S) 4 plenums are available for upflow units: 2 way, 3 way, or 4 way discharge and top duct connection. Each plenum is 18” (457mm) high and constructed of steel with 1” (25.4mm), 1 1/2 Ib. (.68kg) insulation and is custom painted in unit matching colors. STEAM GENERATING CANISTER HUMIDIFIER This system is housed in a steel enclosure and includes a replaceable canister with integral fill cup, fill and drain valves, and high water indicator. System automatically fills and drains as well as maintains the required water level based on conductivity. HEAVY GAUGE INDUSTRIAL PANELS Are 16 ga. outside panels and heavy duty gaskets which replace the standard 20 ga. Panels and gaskets. REHEAT/HUMIDIFIER LOCKOUT Includes the necessary relays to disable the reheat and humidifier from an external 24 volt signal. SCR ELECTRIC REHEAT Is controlled by the unit microprocessor by pulsing the reheat elements for tight temperature control. Not available in 575 volts. HIGH EXTERNAL STATIC BLOWERS This blower/motor package is available only on upflow models where external static pressures are up to 2.0 inches/500 Pa (60Hz) or 1.5 inches/370 Pa (50Hz). These blowers are rigidly mounted for ducting directly to the blower housing. Heavy gauge panels are recommended with this option. 200K HOUR BEARINGS Lifetime lubricated self-aligning pillow-block ball bearings rated at a minimum L10 life of 200,000 hours; available on upflow units only. TWO (2) ADDITIONAL REMOTE SHUTDOWN TERMINALS Provides the customer with a total of three locations to remotely shut down the unit. TWO (2) EXTRA COMMON ALARM CONTACTS Provides the customer with a total of three sets of n/o contacts for remote indication of unit alarms. MAIN FAN AUXILIARY SWITCH Provides the unit with one n/o set of contacts to indicate that the motor/unit is on. REMOTE HUMIDIFIER CONTACTS allow the unit’s humidity controller to control a humidifier outside the unit. Power to operate the remote humidifier does not come from the Challenger unit. INTELLISLOT ISWEB-LBDS CARD Provides 10/100 baseT Ethernet connectivity for unit monitoring and management. The supported management interfaces include: SNMP for Network Management Systems and HTTP for web page viewing. INTELLISLOT OC485-LBDS CARD Provides RS-485 Modbus network connectivity to Building Management Systems for unit monitoring and management. DPN000348 REV 11/11 REV 5 Liebert iCOM® Control System Intelligent Communications & Monitoring Large Graphic Display (Unit or Wall-mounted) Large Graphic Display shown in unit bezel Large Graphic Display for Wall-Mounting The Liebert iCOM® Large Graphic Display shall be microprocessor based with a 320x240 dot matrix graphic monitor with control keys for user inputs mounted in an ergonomic, aesthetically pleasing housing. The display and housing shall be viewable while the unit panels are open or closed. All parameter changes are password protected. Wall-Mounted Large Graphic Displays shall be capable of being mounted on a wall and are provided with a power supply. Wall-mounted displays can be added to a Unit-to-Unit network and remotely located from the cooling unit(s) to provide convenient monitoring and control capabilities. Large Graphic Display only features: The Large Graphic Display provides all of the same features of the Small Graphic Display, plus Large Graphic Display only features. Event Log – Automatically stores the last 400 unit and system (U2U communication required) events (messages, warnings, and alarms) Spare Parts List - shows a list of key spare parts, their quantity and respective parts numbers Unit Diary - A free field area where unit history may be stored for reference View Network – Shows a summarized view of all the cooling units connected on a U2U network Centralized Operation – View and configure any cooling unit on a U2U network from a Large Graphic Display System View – View the averages of all operations being performed on the U2U network Active Alarms on Status Screen – Last two unit/system events are displayed at the bottom of the Status Screen for rapid identification of critical events without having to enter submenus Full Text Descriptions – The large screen size eliminates the need for abbreviated text, simplifying user operation DPN000794 REV 4/09 REV 2 Liebert iCOM® Control System Intelligent Communications & Monitoring Small Graphic Display (Unit-mounted only) Small Graphic Display shown in unit bezel The Liebert iCOM® Small Graphic Display shall be microprocessor based with a 128x64 dot matrix graphic monitor with control keys for user inputs mounted in an ergonomic, aesthetically pleasing housing. The display and housing shall be viewable while the unit panels are open or closed. All parameter changes are password protected. Small Graphic Display Features (additional features available with Large Graphic Display): Temperature Control – Precision temperature control is maintained while maximizing efficiency based on a user entered setpoint and tolerance. Humidity Control – The dewpoint level of the room is monitored and controlled based on a user specified Relative Humidity setpoint and tolerance. Various Control Types – Selectable Proportional, PI (proportional-integral), PID (proportional-integral-derivative), Intelligent control types for supply or return temperature; Relative, Compensated, or Predictive humidity control types. These control types have been developed to maximize component life and maintain precise environmental control. Unit Alarms – All unit alarms are annunciated, displayed on the screen, automatically recorded in the event log, communicated to available IntelliSlot monitoring cards, and a red light flashes on the display Event Log – Automatically stores the last 400 unit-only events (messages, warnings, and alarms). Temperature and Humidity Graphs – Provides a graphical view of historical room conditions, selectable from 8 minutes to 16 days Automatic Component Sequencing – runtimes of multiple components within a unit are automatically balanced to extend component life Wellness / Maintenance – Monitors system components to warn of potential issues in advance (helps avoid unplanned downtime) and prolong component life Auto Restart – After a loss of power, a cooling unit will return to is previous operating status. Cooling units can be stagger started to minimize system current draw. IntelliSlot Cards – IntelliSlot cards allow for external unit communication and control Service Contact Information – Local service or sales contact information can be conveniently stored Upgradeable – Multiple units connected through a Unit-to-Unit network can be upgraded simultaneously or cascaded. Unit-to-Unit (U2U) Communication – Communication via private Ethernet network allows for advanced control functionality (Teamwork modes, sharing sensor data, Standby Rotation, Lead-Lag, and Cascade operation). Small Graphic Displays can only configure the cooling unit they are physically connected to, while Large Graphic Displays can configure any unit on the network. Cascade – Standby units on a U2U network are automatically activated if active unit(s) cannot control the environment Lead-Lag – A standby unit on a U2U network is automatically activated if an alarm occurs in an active unit Standby Rotation – Standby units are rotated through a U2U network to balance system run hours. Units can be set to automatically rotate daily, weekly, or monthly Teamwork modes • Mode No – Units share data but operate independently using local sensor readings • Mode 1 – All units perform the same operation with the same intensity based on sensor readings from the entire network; typically for rooms with balanced heat loads • Mode 2 – All units perform the same operation with varying intensity based on sensor readings from the entire network; typically for rooms with un-balanced heat loads DPN000793 REV 4/09 REV 1 CABINET AND FLOOR PLANNING DIMENSIONAL DATA LIEBERT CHALLENGER 3000 UPFLOW (BU) MODELS STD 3 & 5T Hi Static 3T Hi Static 5T UNIT TOP VIEW 32 1/2" (826mm) 30 1/2" (775mm) A A 11 3/4 (299mm) 8 5/8 (219mm) 11 3/4 (299mm) 8 1/2" (216mm) 9 5/8" (244mm) 10 1/4" (260mm) 13" (330mm) Standard Piping Location 12 1/2" (318mm) Projection of Display Bezel 5/8" (16mm) 5 1/2" (140mm) 32 1/2 " (826mm) Overall Dimension 7 1/2 " (191mm) Filter Access Through Top 18 " (457mm) 32 1/2 " (826mm) Overall Dimension 1 5/8" (41mm) 30 1/2" (775mm) 1 7/8" (48mm) 32 1/2" (826mm) Standard Electrical Outlet Location Through Unit 6 7/8 " (175mm) Standard Electrical Outlet Location Through Plenum Air Discharge Grille 29 3/4 " (756mm) Plenum available with: -2, 3 or 4 grilles. -Solid sides with a 7/8" (22mm) duct flange on top. 1" (25mm) FRONT & SIDES 3/4" (19mm) REAR 94 " (2388mm) 2 1/2 " (67mm) 29 " (737mm) UNIT DIMENSIONAL DATA REAR VIEW (rear return configuration) 50 HZ MODELS BU035E BU059E BU040A BU065A BU045W BU070W BU072C BU101C BK058G DPN000350 UNIT WEIGHT 60 HZ MODELS BU036E BU060E BU042A BU067A BU046W BU071W BU068C BU102C BK061G 76 " (1930mm) 1 3/4 " (44mm) LBS. (KG) 535 (243) 545 (247) 615 (279) 670 (304) 700 (318) 750 (340) 545 (247) 555 (252) 785 (356) Blower Outlet with 1" (25.4mm) Flange 7/8" (22.2mm) Flange for Duct or Plenum Connection Return Air Louvers Shaded area indicates a recommended clearance of 34" (864mm) be provided for component access. Right side access suggested for "GLYCOOL" units. UNIT DIMENSIONAL DATA FRONT VIEW (front return configuration) REV 4/09 REV 1 PIPING: AIR COOLED MODELS UPFLOW (BU) MODELS Piping outlet locations through the plenum are the same as the unit. See below for descriptions and connection sizes. Humidifier Water Supply Line 1/4" OD CU Hot Water Return 5/8" OD CU (optional) Hot Gas Refrigerant Line 5/8" OD CU on Models BU042A/BU040A 7/8" OD CU on Models BU067A/BU065A Condensate Pump Line 1/2" OD CU Used only if optional condensate pump is ordered. Liquid Refrigerant Line 3/8" OD CU on Models BU042A/BU040A 1/2" OD CU on Models BU067A/BU065A Hot Water Supply 5/8" OD CU (optional) iCOM Control Panel Condensate Drain 3/4" FPT Field pitch a min. of 1/8" (3.2mm) per ft. (305mm). Units without a condensate pump have a factory-supplied trap in the unit, so a field trap should not be added. Units with a condensate pump will require a field-supplied trap downstream from the pump. The drain line must comply with all applicable codes. (If condensate pump is ordered piping is out top of unit). DPN000352 PIPING OUTLET LOCATIONS (See Cabinet and Floor Planning Dimensional Data for Piping Opening Sizes.) REV 9/08 REV 1 LIEBERT® CHALLENGER ELECTRICAL FIELD CONNECTION DEFINITIONS AND LOCATIONS 1 1 2 50Hz Only 5 4 9 9 3 w/ MAIN DISCONNECT Terminal Block* (for customer connections) 14 75 76 94 95 96 97 w/o MAIN DISCONNECT 6 7 10 6 7 1 8 14 2 60Hz Only 1 8 10 11 37C38C37B 38B 37 38 24 50 51 55 56 13 91 92 93 1 12 2 3 16 4 Electrical Handy Box* (factory installed with cover) 15 17 18 82 83 84 85 88 89 73 72 71 70 1) Electric conduit knockouts on top and bottom of electric box. Knockout size 1 3/4” (44.5mm). 2) Three phase connection. Electric service connection terminals when factory disconnect is NOT supplied. 3) Three phase connection. Electric service connection terminals when factory disconnect switch is supplied. 4) Factory installed disconnect switch (Optional). Fused disconnect switch provided on 60Hz units, non-fused disconnect switch provided on 50Hz units. 5) Factory installed main fuse block (60Hz only). Factory installed when fused disconnect switch is NOT supplied. 6) Three phase electric service field supplied. 7) Earth ground connection (50/60Hz). Connection terminal for field supplied earth grounding wire. 8) Earth ground bar (50Hz only). Connection terminals with factory ground from each high voltage component for field supplied earth grounding wire. 9) Control and monitoring section of electric box. 10) Remote unit shutdown. Replace existing jumper between terminals 37 + 38 with normally closed switch having a minimum 75VA, 24VAC rating. Use field supplied Class 1 wiring. Two additional contact pairs available as an option (labeled as 37B & 38B, 37C & 38C). Replace existing jumper for appropriate pair as done for 37 & 38. 11) Remote Alarm Device (RAD) Connections. Field supplied 24V Class 1 wiring for special alarm. Connection made by adding normally open contacts. Special alarm connections may be factory wired or field wired. See schematic, RADS1-4, for factory wired special alarms. For field wired special alarms, use 24V Class 1 wiring to connect normally open contacts between terminals 24 & 50, 24 & 51, 24 & 55, or 24 & 56. 12) Remote condensing unit connection. Field supplied 24V Class 1 wiring to remote condensing unit terminals 1, 2, 3, & 4 from (R2) relay (split system only.) 13) Smoke detector alarm connections. Field supplied 24V Class 1 wiring to remote alarm circuits. Factory wired contacts from optional smoke detector are #91-comm., #92-NO, and #93-NC. 14) Common alarm connection. Field supplied 24V Class 1 wiring to common alarm terminals 75 + 76 (and optional 94 + 95, and 96 + 97), which are factory connected to common alarm relay (R3). 15) Heat rejection connection. Field supplied 24V Class 1 wiring to interlock heat rejection from pigtails 70 + 71 which are factory connected to compressor side switch (self contained units only) or to GLYCOOL relay (K11, GLYCOOL units only). On Dual Cool units only, pigtails 72 + 73 connect auxiliary cooling source to GLYCOOL relay K11. See indoor and outdoor electric schematic for more information. 16) Reheat and Humidifier Lockout. Optional emergency power lockout of reheat and/or humidifier: connections provided for remote 24V AC source. 17) Main Fan Auxiliary Switch. Optional main fan auxiliary side switch. Terminals located in field wiring compartment for remote indication that the evaporator fan motor/unit is on. Field to connect 24V maximum. 18) Optional Condensate Alarm (Dual Float Condensate Pump only). Relay terminals located in field wiring compartment for remote indication. *Located inside unit on top for Upflow and on base for Downflow. NOTE: Refer to specification sheet for full load amp and wire size amp ratings. DPN000354 REV 03/13 REV 4 ELECTRICAL FIELD CONNECTIONS - NETWORKING - U2U UPFLOW LIEBERT CHALLENGER MODELS WITH iCOM CONTROLS CAT5 Ethernet connections - field installed Avoid routing near high voltage wiring. Secure wiring to prevent damage and use bushing or edge guard to avoid sharp edges. 2 Loose Cable Ties To Display To P64 To Display Use cutout on the electric box to access control board. Crossover Coupler Crossover Coupler A DETAIL A Ethernet Wiring Notes: 1. On units with the standard Small Graphics Display, the customer connection point for unit to unit (U2U) networking is to P64 on the I/O Board. Channel Blower Blockoff Plate 2. On units with the optional Large Graphics Display, a crossover coupler is provided for unit to unit (U2U) networking. Unplug the red cable from P64 on the I/O Board and connect to one side of the crossover coupler. The first customer connection point is to P64 on the I/O Board. The second customer connection point is to the other side of the crossover coupler. This connects the I/O Board and display to the private U2U network. DPN001733 Cable Tie To Secure Wiring PAGE 1 OF 3 REV 12/12 REV 2 ELECTRICAL FIELD CONNECTIONS - NETWORKING - U2U UPFLOW LIEBERT CHALLENGER MODELS WITH iCOM CONTROLS 21 22 19 23 24 20 Terminal Blocks 19) Opening for field wiring. Suggested entry point for HV field wiring to unit. Hole size O 2.5" (63.5 mm) 20) Opening for field wiring. Suggested entry point for LV field wiring to unit. 21) Vacant Intellisot. May contain optional Intellislot cards. 22) Populated Intellislot. Optional Intellislot cards may be placed in either of two supplied Intellislot locations. 23) Remote Temperature / Humidity Sensor connection location. 6-wire CAN cable supplied with optional remote T/H sensor. 24) Loose cable ties. Use to secure field supplied network cables to Intellislot. DPN001733 PAGE 2 OF 3 REV 12/12 REV 2 ELECTRICAL FIELD CONNECTIONS - NETWORKING - U2U UPFLOW LIEBERT CHALLENGER MODELS WITH iCOM CONTROLS U2U NETWORKING CONNECTIONS - SMALL DISPLAY P66 P64 Customer Connection Point FIGURE 1 1. When Large Display is used, two cables are required. 2. To run both wires through the channel at the same time, bundle them together as Figure 1 shows. U2U NETWORKING CONNECTIONS - LARGE DISPLAY On units with the optional Large Graphics Display, a crossover coupler is provided for unit to unit (U2U) networking. Unplug the red cable from P64 on the I/O Board and connect to one side of the crossover coupler. The first customer connection point is to P64 on the I/O Board. The second customer connection point is to the other side of the crossover coupler. This connects the I/O Board and display to the private U2U network. When Large Display is used, two cables are required. P66 Customer Connection Points DPN001733 P64 PAGE 3 OF 3 REV 12/12 REV 2 LIEBERT LIQUI-TECT® 410 Point Leak Detection Sensor Product Specification Sheet Description The Liebert Liqui-tect 410 (LT410) provides a single-point detection of leaks. The point detection sensor has two gold-plated sensing probes to prevent corrosion resistance and to provide accurate readings. The LT410 constantly monitors points for leaks, internal faults and power failures and warns of any abnormal conditions. Mounting brackets allow for sensor height adjustment and leveling. The LT410 is the ideal solution for sensing leaks under a raised computer floor or air conditioning drip pans. Two independent outputs provide added flexibility with the capacity to signal both a local alarm panel and a remote building management system or external equipment, such as motorized water shut-off valves. The LT410 is also ideally suited for the following: Applications Locations • Glycol, Chilled Water Cooling • Large-Scale Network Control Centers • Mechanical Equipment Rooms • Data Centers • Sensitive Areas With Overhead Piping • Humidification Feed Water Piping • Condensate Pumps and Drains • Unit and Ceiling Auxiliary Drip Pans • Overhead Piping Troughs • Server Rooms - Closets • Unattended Remote Shelters • Industrial Process Control Rooms Dimensions - Top, Front & Side Views TOP VIEW FRONT VIEW SIDE VIEW 5.85" (148.5mm) 4.46" (113.2mm) Form-C relay outputs & power wiring connection 6.35" (161.2mm) Adjustable probe height 0.0–0.5" (0.0–12.7mm) Shipping weight: 2 Ibs (0.9 kg) Mounting holes: #8 screws 1 2.25" (57.2mm) Specifications Placement on Subfloor Under Cooling Support Equipment Liqui-tect 410 Sensor Power requirements 24 VAC 100 mA, 50/60 Hz, 3 VA (max.) Dimensions, in. (mm) 6.35" x 2.25" x 4.46" WxDxH (161.2 x 57.2 x 113.2) Weight (assembled) 2.0 lb. (0.9 kg) Metal enclosure NEMA 1, IP 30 To a Liebert environmental unit and an optional* monitoring panel Environmental Conditions Operating temperature 50°F to 104°F (10°C to 40°C) Operating humidity 10% to 95% relative humidity (non-condensing) Operating altitude 0 to 10,000 ft. (0 to 3,048 m) To external power supply or directly from unit (see Power Wiring on 3) Output Relays Contact rating 2 Form-C; 3 A rating at 24 VAC Agency Listings UL UL916 C-UL C22.2, No. 205-M1983 CE Yes FCC Compliance 47 CFR, Part 15 LT410 * Output connections to external alarm monitoring panels such as the Liebert contact closure alarm panels Wiring Interconnections (Circuits shown in powered, non-alarm state) 24 VAC @ 3A 24 VAC @ 3A Class 2 Circuit Only Class 2 Circuit Only Class 2 Circuit Only Gold-plated probes Height adjustable 0-0.5" (0-12.7mm) NOTE: All power and alarm connections Class 2 circuits only 2 2-COM @ 0.10A, 50-60 Hz, DC 2-NC Alarm Contact Rating 2-NO Alarm Contact Rating 1-COM 24 V, AC/DC 1-NC Yellow Wires 1-NO Orange Wires Power Red Wires Power Leak detection zone (directly beneath unit) Power Wiring The LT410 is rated for 24 VAC, 50/60 Hz and 0.10 amp. Figure 1 24V from Liebert environmental units to LT410 Challenger, Himod or Liebert Deluxe System/3, MM2DS, (8 Ton) Challenger, Himod or Mini-Mate2 (8 ton) TB1 TB1 LT460 LT410 Red wires TB1 T5 (24V) T5 (24V) Red TB1-1 G5 (Ground) (Ground) G5 Red TB1-2 Liebert MM2 (1 to 5 Ton) LT460 TB1 Power Wiring 4V transformer of (24V) here are no ated terminal 24V(Ground) from Liebert tions) TB1-1 Environmental Unit to LT460 Liebert Deluxe Sys/3, 24V fromHimod Transformer Challenger, or MM2 (8 Ton) T5 (24V) connection on main controller board of Liebert unit to LT460 Transformer LT460 LT460 TB1 TB1 TB1 T5 (24V) G5 TB1-2 Location of TB1-1 TB1-1 TB1-2 TB1-2 From 24V transformer (Ground) MM2 (1 to(15 to Ton) LiebertLiebert Mini-Mate2 5 ton) LT460 LT410 Red wires TB1 4V transformer of (24V) here are no From 24V ated terminal transformer* (Ground) tions) Red TB1-1 Red TB1-2 * Requires a 24V external transformer (there are no designated terminal connections on the unit) 24V from Transformer to LT460 Figure 2 24V from transformer to LT410 Transformer Transformer LT460 LT410 Red wires TB1 From 24V24V From transformer transformer Red TB1-1 Red TB1-2 3 Wiring to Auxiliary Alarm Panels The LT410 has two Form-C dry contact alarm output contacts: orange wires (1) and yellow wires (2). Each contact is rated for 24 VAC at 3 amp. Figure 3 LT410 to Liebert environmental units Liebert Deluxe Sys/3, Challenger, Himod or MM2Liebert (8 Ton) DS LT460 LT410 Orange TB2wires Environmental Env.unit Unit TB2-3 1-NC (N.C.) TB2-2 1-COM(C) 24 (24V) (24V) TB2-1 1-NO (N.O.) 51 50, 51, 55 or 56 LT410 Liebert Deluxe System/3, Liebert MM2 (1 to 5 Ton)or Challenger, Himod Mini-Mate2 (8 ton) LT460 Orange TB2wires Environmental Env.unit Unit TB2-3 1-NC (N.C.) TB2-2 1-COM(C) TB1-1 (24V) 24 (24V) TB2-1 1-NO (N.O.) TB1-2 51, 55 or 56 OR LT410 LT460 Orange TB2wires Liebert Mini-Mate2 Liebert MM2 (1 to 5 Ton) (1 to 5 ton) Environmental Env.unit Unit 1-NC (N.C.) TB2-3 1-COM(C) TB2-2 (24V) TB1-1 (24V) 1-NO (N.O.) TB2-1 TB1-2 or TB1-3 TB1-3 Figure 4 LT410 to Liebert contact monitor panel Liebert Contact Liebert contact Monitor Panel monitor panel LT460 LT410 Yellow TB2wires 2-NC (N.C.) TB2-3 Alarm panel Panel Input contact Contact (N.O.) (N.O.) 2-COM(C) TB2-2 2-NO (N.O.) TB2-1 Ordering Information Product Number Quantity LT410 3 Description Point Leak Detection Sensor Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Telephone: 1-800-877-9222 Facsimile: 1-614-841-6022 www.liebert.com © 2007 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-31050_REV0_06-07 4 LIEBERT® INTELLISLOT® UNITY PLATFORM CARDS Product Specification/Installation Sheet Liebert Intellislot Unity cards are a form, fit and function replacement for several existing Liebert Intellislot Web and 485 cards. RS-485 - Modbus RTU, BACnet MSTP, YDN23; Building Management System RJ-45-Ethernet—Trellis; Modbus TCP; BACnet IP; SNMPv1, v2c, v3; Liebert Protocol; HTTP; Building Management System; Network Management System Micro-USB AB (future release) IS-UNITY-DP Reset Button (Reboot or reset to factory defaults) Link 485 Activity Liebert Sensor Network (future release) Description The Liebert IntelliSlot Unity Platform brings SNMP, BACnet IP, BACnet MSTP, Modbus TCP, Modbus RTU, YDN23 and Web management capability to many models of Emerson Network Power’s power and cooling equipment. The cards employ Ethernet and RS-485 networks to monitor and manage a wide range of operating parameters, alarms and notifications. See Table 1 for equipment supported and Table 2 for communication protocols supported. Additional Features • SNMPv1, SNMPv2c and SNMPv3 with MIB-II support • DHCP per RFC2131/2132 • HTTP/HTTPS 1.1 • Remote firmware updates via a Web browser • BootP • IPv4 and IPv6 Compatibility With Other Emerson Products and Communication Protocols Table 1 Compatibility with Liebert equipment Compatible with: Liebert IntelliSlot Card ™ Liebert APM , Liebert APS , Liebert CRV™, Liebert CW™, Liebert Challenger 3000™ Liebert DCP™, Liebert Deluxe System/3™, Liebert DS™, Liebert DSE™, Liebert HPC™ Liebert HPC-S/M/R/W/Generic™, Liebert HPM™, Liebert NXC™, Liebert NXL™ *, Liebert NXR™, Liebert PCW™/PDX™, Liebert PeX™ *, Liebert XDC™, Liebert XDP™, Liebert XDP-Cray™ Liebert IS-UNITY-DP Liebert IS-UNITY-LIFE Table 2 ™ Liebert IntelliSlot card communication protocols Communication Protocol HTTP HTTPS Emerson Protocol Remote Service Delivery Protocol Liebert IS-UNITY-DP (IS-UNITY-DP) ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Liebert IS-UNITY-LIFE (IS-UNITY-LIFE) ✔ ✔ ✔ — — — — — — Liebert IntelliSlot Card (Part #) * Email SMS SNMP v1, v2c, v3 BACnet IP BACnet MSTP Modbus TCP Modbus RTU YDN23 * YDN23 supported only for Liebert PeX and Liebert NXL. 1 Dimensions 1/2" (11mm) Top of Liebert IntelliSlot Unity Card 3" (76mm) 1- 1/2" (38mm) 2-3/8" (60.3mm) Front of Liebert IntelliSlot Unity Card 4-3/4" (121mm) Specifications DC Inputs Power Requirements Power Consumption Dimensions - W x D x H: in. (mm) Shipping, lb. (kg) Ambient Operating Environment, °F (°C) • 7 (0.2) • 1.3 (0.6) • 32 to 104 (0 to 40); 10% to 90% RH (non-condensing) Ambient Storage Temperature, °F (°C) Communication Ports • 3.6W maximum • 2.97 x 5.2 x 1.45 (75.5 x 15 x 37) Net, oz. (kg) Weight • 7 to 12VDC • -4 to 140 (-20 to 60) Ethernet Communications RS-485 • RJ-45 • RJ-45 (RJ-45 to 2-Position Terminal Block Adapter) Wiring Specifications Maximum Wire Length Connection Supported Wire Type 10/100Mb/s Ethernet Connector Standard Category 5E Cable 328 ft. (100m) RJ-45 - One-Wire Connector Liebert® Integrated One-Wire Sensor Cable or 2m Cat 5E to Modular 1-Wire Sensor. 65.6 ft. (20m) RJ-45 - RS-485 Connector ADAPTER RJ45-2POS TERMINAL BLOCK EIA485 to 18-22 AWG Stranded & Shielded 18 AWG recommended Non Plenum - Belden 9461 Plenum - Belden 88761 3000 ft. (914m) Micro-USB AB Standard Micro-USB AB 16.4 ft. (5m) Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Telephone: 1-800-877-9222 Facsimile: 1-614-841-6022 www.liebert.com © 2012 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-52646_REV4_06-14 2 LIEBERT MC PREMIUM EFFICIENCY CONTROL STANDARD FEATURES COIL Liebert microchannel coils are all‐aluminum construction. Tubes are created by extruding small parallel refrigerant flow paths into aluminum. Full‐depth louvered aluminum fins fill spaces between the tubes. Tubes, fins and aluminum headers are oven‐brazed to form a complete refrigerant‐to‐air heat exchange coil. Baffles are used in the headers to separate one coil slab into multiple passes as needed. Coils are factory leak tested at a minimum of 300 PSIG and dehydrated. Copper stub pipes are electric resistance welded to aluminum coils and joints are protected with polyolefin to seal joint from environmental corrosive elements. Hot gas and liquid lines are brazed to the stub pipes with spun closed ends for customer piping connections. Coil pipe assembles are filled and sealed with a nitrogen holding charge for shipment. One coil is used per fan assembly. FAN/MOTOR ASSEMBLY The fan/motor assembly is complete with external rotor motor, fan blades and fan/finger guard. Fan blades are constructed of stamped aluminum or steel extrusion coated with PP plastic. Fan guards are heavy gauge, close meshed, steel wire, coated with a black corrosion resistant finish. Fan terminal blocks located on the top of the fan guard with IP54 protection class. Fans are factory balanced and tested before shipment. Fan Motors Fan motors are specifically designed for variable speed and have ball bearings. The EC fans provide internal overload protection through the built‐in electronics. Each EC fan motor has built‐in controller and communication module, linked via RS485 communication wire to each fan and the Premium Control Board. This allows each fan to receive and respond to precise fan speed inputs from the Premium control board.. PREMIUM EFFICIENCY FAN CONTROL The Liebert premium efficiency condenser control system is complete with control board, EC fan motor(s),refrigerant‐pressure transducer(s), refrigerant‐temperature thermistor(s), ambient‐temperature thermistor, and motor overload protection in the factory wired control panel. The control board maintains EC fans on the same circuit to the same speed in order to maintain refrigerant head pressure. The control board receives a run signal from the compressor of the indoor unit via field‐supplied low voltage interlock wires or with optional, field‐supplied CANBUS communication wires from the indoor unit iCOM. The system head pressure can be maintained to a minimum ambient temperature of 0 °F (‐18 °C). HOUSING The condenser housing is constructed of bright aluminum sheet and divided into individual fan sections by full width baffles. Internal structural support members, including coil support frame, are galvanized steel for strength and corrosion resistance. Panel doors are provided on two sides of each coil/fan section to provide for coil cleaning. Aluminum legs are provided with rigging holes for hoisting the unit into position. UNIT DISCONNECT SWITCH Locking unit disconnect switch is factory installed and wired in attached condenser control section. OPTIONAL FEATURES LIEBERT LEE‐TEMP LOW AMBIENT CONTROL Lee‐Temp receiver kits can be added to achieve head pressure control down to minimum ambient temperatures of ‐30 °F (‐34 °C). The premium efficiency fan control when used with the Liebert Lee‐Temp receiver kits runs the fan(s) at lower speeds during cold temperatures saving fan energy. COMMUNICATION The Premium Efficiency Control system provides future communication links with the iCOM control of the indoor Liebert precision air conditioner. The communication link allows for condenser alarm condition communication to iCOM, communication of other measurable items on the condenser, and future condenser/fan control features to improve efficiency, sound and wintertime operation based on iCOM programming. DPN002155 REV 06/11 REV 0 LIEBERT MC CABINET & ANCHOR DIMENSIONAL DATA MCS028 & MCS056 WITH LEE-TEMP RECEIVER 42 3/4" (1085m m ) Emerson recommends a clearance of 36” (915mm) on each side for proper operation and component access. E* HEIGHT TO TOP OF FAN GUARD C E B A 575V TRANSFORMER ENCLOSURE OPTION 15 1/4" (387m m ) D 42 1/2" (1080m m ) FOR DUAL CIRCUIT ONLY 15 1/4" (387m m ) ANCHOR PLAN LEG HEIGHT 42 1/2" (1079mm) B C IN. (MM.) IN. (MM.) IN. (MM.) 18 (457) 31 5/8 (803) 39 5/8 (1006) 36 (914) 49 5/8 (1260) 57 5/8 (1464) 48 (1219) 61 5/8 (1565) 69 5/8 (1768) 60 (1524) 73 5/8 (1870) 81 5/8 (2073) A* PROVIDED ON 2-FAN MODEL Electric Box End F 35 7/8" 40 7/8" (910mm) (1038mm) Typical condenser footprint dimensions *Cross bracing required for legs longer than 18”. Quantity varies per 13/16" (21mm) 2 1/2" (64mm) model and options selected. 3 5/8" (93mm) 1 7/8" (48mm) 2 1/2" (64mm) D E E*(575V) F FANS IN. (MM.) IN. (MM.) IN. (MM.) IN. (MM.) MCS028 1 44 1/8 (1120) 50 5/8 (1287) 58 7/8 (1495) -- MCS056 2 88 3/8 (2245) 94 7/8 (2411) 103 1/8 (2619) 44 1/4 (1124) LIEBERT MODEL NO. 1/2"(12.7mm) x 1"(2 5.4mm) OBROUND 3 5/8" (93mm) NO. 1 7/8" (48mm) DPN002373 REV 5/14 REV 5 LIEBERT MC PIPING: DIMENSIONAL DATA WITH LEE-TEMP SINGLE CIRCUIT CONDENSERS METAL CLAMP ISOLATOR DETAIL A-A HOT GAS LINE TO CONDENSER ENTERING HOT GAS LINE FIELD PIPING COVER * B VIEW B VIEW POSITION ELBOW TO DIRECT RELIEF VALVE DOWNWARD LIQUID LINE FROM CONDENSER GENERAL ARRANGEMENT LEAVING LIQUID LINE FASTEN HOT GAS LINE TO CABINET USING FLAT SURFACE CLAMPS WITH ISOLATORS(FIELD SUPPLIED) SEE DETAIL A-A LIEBERT SUPPLIED PIPING ASSEMBLY WILL INCLUDE 1 TO 3 VALVE AND CHECK VALVES DEPENDENT ON CONDENSER CAPACITY AND REFRIGERANT. NOTE: 1.THE FOLLOWING MATERIALS ARE SUPPLIED BY LIEBERT,SHIPPED LOOSE FOR EACH CIRCUIT AND FOR FIELD INSTALLATION: INSULATED LEE-TEMP RECEIVER TANK WITH ELECTRIC HEATER PADS AND SIGHT GLASSES, PIPING ASSEMBLY WITH HEAD PRESSURE CONTROL VALVE AND CHECK VALVE, ROTO-LOCK VALVE AND PRESSURE RELIEF VALVE. ALL OTHER PIPING AND ELECTRICAL WIRING TO BE SUPPLIED AND INSTALLED BY OTHERS. ADDITIONAL CONDENSER LEG PER CIRCUIT WHEN REQUIRED, SHIPS WITH THE CONDENSER. 2.FOR RUNS LONGER, THAN 150FT.(45.7M)EQUIV. LENGTH, CONSULT FACTORY FOR PROPER LINE SIZING. CONDENSER PIPING CONNECTION SIZES LEE-TEMP CONNECTIONS CONDENSER CONNECTIONS(ODS-INCHES) MODEL NO. CONDENSER CIRCUITS HOT GAS LIQUID MCS028 1 7/8 5/8 HOT GAS TEE LIQ TO L-T VALVE (IDS-INCHES) (ODS-INCHES) 7/8 5/8 RECEIVER OUT ROTO LOCK (IDS-INCHES) 5/8 MCM040 1 7/8 5/8 7/8 5/8 5/8 MCM080 1 1-1/8 7/8 1-1/8 7/8 1-1/8 MCL055 1 1-1/8 7/8 1-1/8 7/8 7/8 MCL110 1 1-3/8 1-1/8 1-3/8 1-1/8 1-1/8 MCL165 1 1-3/8 1-1/8 1-3/8 1-1/8 1-1/8 MCL220 1 1-5/8 1-3/8 1-5/8 1-3/8 1-3/8 * SHIPPING COVER IS NOT NECESSARY FOR PROPER CONDENSER OPERATION AND MAY BE RECYCLED IF FIELD PIPING INTERFERES WITH PROPER REATTACHMENT. DPN002167 REV 08/14 REV 5 LIEBERT MC PIPING SCHEMATIC CONDENSER WITH AND WITHOUT LIEBERT LEE-TEMP Check Valve Service Valve Relief Valve LIQUID RETURN Head Pressure Control Valve LEE-TEMP RECEIVER Check Valve CONDENSER COIL CONDENSER COIL OPTIONAL FIELD INSTALLED FUSIBLE PLUG HOT GAS DISCHARGE LEE-TEMP LIQUID Sensing Bulb For rises over 25ft. (7.6m), trap every 20ft. (6m) or evenly divided* EVAPORATOR COIL SUCTION Service Valve Service Check Valve Valve COMPRESSOR Field installed relief valve(s) required for 50Hz EU CE units. External Equalizer *Isolation Valve HOT GAS DISCHARGE Expansion Valve Solenoid Valve Sight Glass Filter Drier LIQUID LINE *Isolation Valve Trap at base of risers over 5ft. (1.5m)* NOTE: SINGLE REFRIGERATION CIRCUIT SHOWN FOR CLARITY. REFRIGERANT PIPING *Components are not supplied by Liebert but are required for proper circuit operation and maintenance FIELD PIPING SERVICE/SCHRADER (ACCESS) CONNECTION NO VALVE CORE SERVICE/SCHRADER (ACCESS) CONNECTION WITH VALVE CORE NOTE: SCHEMATIC REPRESENTATION SHOWN. DO NOT USE FOR SPECIFIC CONNECTION LOCATIONS. DPN002188 REV 6/14 REV 3 LIEBERT MC ELECTRICAL FIELD CONNECTIONS PREMIUM EFFICIENCY CONTROL WITH LEE-TEMP Electrical Connections for Lee-Temp Receiver Lee-Temp receiver tank (1 per circuit). NOTE: Heater pad voltage available for 120V/1 phase/60 Hz or 230V/1 phase/60Hz 150 or 300 Watt, varies by condenser. FAN2 FAN1 Electrical connection box with cover. (Cover removed for clarity.) Electrical service connection. Pigtails in electric handy box are factory wired to Lee-Temp heater pads for field connection of separate continuous electric source, wire not by Liebert. KEY ELECTRICAL DETAILS: 1) Three phase electrical service – Terminals are on top of disconnect switch for one and two fan units. Terminals are on bottom of disconnect switch for three and four fan units. Three phase service not by Liebert. See Note 5 (below). 2) Earth ground – Field lug terminal for earth ground connection. Ground terminal strip for fan motor ground connection. 3) Primary high voltage entrance – Two 7/8” (22.2mm) diameter knockouts located at the bottom of the enclosure. 4) SPD field connection terminals – High voltage surge protective device (SPD) terminals. SPD is an optional device. DPN002374 Page 1 of 3 REV 4 REV 05/14 LIEBERT MC ELECTRICAL FIELD CONNECTIONS PREMIUM EFFICIENCY CONTROL WITH LEE-TEMP 5) CANbus terminal connections – Field terminals for CANbus cable connection. 5A is the CANbus connectors. o TB49-1 is the input terminal for CANbus high. o TB49-3 is the input terminal for CANbus low. o TB50-1 is output terminal for CANbus high. o TB50-3 is the output terminal for CANbus low. o Each CANbus cable shield is connected to terminal “SH”, item 9. 5B is the “END OF LINE” jumper. 5C is the CANbus “DEVICE ADDRESS DIP SWITCH”. CANbus cable not by Liebert. See Note 2 (below). 6) Remote unit shutdown – Replace exiting jumper between terminals TB38-1 and TB38-2 with field supplied normally closed switch having a minimum 75VA 24VAC rating. Use field supplied Class 1 wiring. (This is an optional feature that may be owner specified.) 7) Alarm terminal connections – a. Common Alarm Relay indicates when any type of alarm occurs. TB74-1 is common, TB74-2 is normally open, and TB74-3 is normally closed. 1 Amp 24VAC is the maximum load. Use Class 1 field supplied wiring. b. Shutdown Alarm Relay indicates when condenser loses power, or when a critical alarm has occurred that shuts down the condenser unit. TB74-4 is common, TB74-5 is normally open, and TB74-6 is normally closed. 1 Amp 24VAC is the maximum load. Use Class 1 field supplied wiring. 8) Indoor unit interlock and SPD alarm terminals – a. On any call for compressor operation, normally open contact is closed across terminals 70 & 71 for Circuit 1, and normally open contact is closed across terminals 70 & 230 for Circuit 2 from indoor room unit. b. During SPD alarm, normally open contact is closed across terminals 12 & 13. SPD is an optional device. 9) CANbus shield terminal – Terminal for field connection of the CANbus field supplied cables. Shield of CANbus field supplied cables must not be connected to ground. 10) Primary low voltage entrance – One 7/8” (22.2mm) diameter knockout that is free for customer low voltage wiring. 11) SPD entrance – One 7/8” (22.2mm) diameter knockout hole located at the bottom of the enclosure. High voltage surge protective device (SPD) is optional. NOTES: 1. Refer to specification sheet for unit voltage rating, full load amp, and wire size amp ratings. 2. The CANbus wiring is field supplied and must be: a) shielded b) 22-18AWG stranded tinned copper, c) twisted pair (minimum 8 twists per foot), d) low capacitance (15pf/ft or less), e) plenum rated(NEC type CMP) if required by local codes, f) UV and moisture resistant or run within conduit once in an outdoor environment, and g) must be temperature and voltage rated for conditions present. h) Examples: Belden part number 89207(plenum rated) or Alpha Wire part number 6454 (UV resistant outdoor rated) category 5, 5e or higher. 3. Do not run the CANbus cable in the same conduit, raceway, or chase as high voltage. 4. For CANbus network lengths greater than 350ft(107m), contact Liebert factory. 5. All wiring must be sized and selected for insulation case per NEC and other local codes. DPN002374 Page 2 of 3 REV 4 REV 05/14 LIEBERT MC ELECTRICAL FIELD CONNECTIONS PREMIUM EFFICIENCY CONTROL WITH LEE-TEMP 6. The electrically commutated (EC) motors included in the Liebert MC Condenser are suitable for connection to power supplies with a solidly grounded neutral. (Some platforms can accept power supplies listed under item b below. Contact the factory for more information.) a) Acceptable power supplies for 208 to 575V nominal unitsi. 208V wye with solidly grounded neutral and 120V line to ground; ii. 380V wye with solidly grounded neutral and 220V line to ground; iii. 480V wye with solidly grounded neutral and 277V line to ground. iv. 575V wye with solidly grounded neutral and 332V line to ground. (uses step-down transformer) b) Non-acceptable power supplies for 208V to 575V nominal units – i. wye with high resistance (or impedance) ground; ii. delta without ground or with floating ground; iii. delta with corner ground; or iv. delta with grounded center tap. DPN002374 Page 3 of 3 REV 4 REV 05/14