Laparoscopic Hysterectomy Morcellator
Transcription
Laparoscopic Hysterectomy Morcellator
67273 EN V40/14 • NOUVAG AG©, all rights reserved • Subject to change Laparoscopic Hysterectomy Morcellator Laparoscopic Hysterectomy Nowadays newly developed medical devices make hysterectomy possible by a laparoscopic intervention. The advantage for the patient of the laparoscopic method is less pain and a much faster recovery. Patients appreciate much the minimal invasive character of this operation because it leaves almost no scars on the patient’s skin, reduces the healing of the wounds and safes money and time for all involved parties. Incision If the uterus requires complete removal (up to the outer cervix), the incision is made at the ceramic cap and then it is sutured. The severed uterus is excised from the abdominal cavity piece by piece with the morcellator and aspirated. In the case of a supracervical hysterectomy the uterus is severed above the inner cervix. Depending upon the diagnostic findings the physician opts either to remove the uterus through the vagina or by laparoscopic means. In the event of a higher risk, for example, due to an enlarged uterus and 2 thus reduced visibility and constricted space, the surgery can be concluded by means of an abdominal incision. The uterus can, however, invariably be removed using morcellation in all the variants on a hysterectomy. al vic y y er m om ac to ct l pr ec ta re Su ster To yste hy h Laparoscopic access A manipulator (guide instrument) is inserted into the uterus via the vagina to enable it to be moved during the operation. A ceramic cap over the cervix later allows it to be safely withdrawn from the vagina. The abdominal cavity is filled with gas (CO2) through a thin cannula in order to elevate the abdominal wall and provide an unobstructed view of the abdominal organs. The camera optics is inserted in the umbilical area through a percutaneous access route. The required surgical instruments (e.g. electric scissors, morcellator, haemostatic clamps, etc.) are inserted in the lower abdomen through small (5 – 10 mm) incisions. The camera passes the image to a large monitor. The modern optics and instruments provide an unobstructed view and so ensure safe surgery. Uterus Inner Cervix Cervicalchannel Outer Cervix Vagina Morcellation with Protection Sleeve At the Hysterectomy in laparoscopic surgery the Morcellator is inserted into the abdominal cavity with the Obturator inserted in the Protection Sleeve. After removing the Obturator, the Cutting Tube can be inserted. To expose the Cutting Tube to the tissue that has to be removed, the Protection Sleeve has to be unlocked from the Non-cutposition by holding the Transmission Unit with one hand and performing a counter movement of the Protection Sleeve with the other hand. Morcellation with Trocar Sleeve When morcellating with a Trocar Sleeve the abdominal wall is kept in save distance from the operation area by inflating the abdominal cavity. This gives also safe clearance for the surgical operation. The Trocar Sleeve stays flexible while operating, means it can be rotated against the organ or tissue to be protected. Only than the Obturator is removed and the Cutting Tube can be inserted. The configuration of instruments needed for this procedure are shown on the System chart under option 2. Under option 1 the configuration with the Cutting Tube is shown. TCM 3000 BL - Morcellator The compact control unit TCM 3000 BL - Morcellator with its simple and intuitive operation panel controls the speeds of the attached instruments. For the morcellation of tissue speeds of up to 1000 rpm are appropriate. • Compact and practical unit • Variable speed in Vario mode, continuously controllable by pedal • Choose between 3 Vario programs with specific speed ranges, alternatively to free callable speed ranges • Simple, intuitive operation • Valuable, sturdy architecture • Pedal with precise control Technical data Type: TCM 3000 BL – MORCELLATOR Mains voltage: 100/115/230 Volt at 50 – 60 Hz Power consumption: 60 VA Max. torque: 80 Ncm Motor cable length: 3m Speed range, Morcellator: up to 1000 rpm Dimensions, control unit (Width/depth/height): 120/180/107 mm Weight, control unit: 1.8 kg Controls: Vario pedal 3 Cutting Tubes, Protection Sleeves, Obturators To suit the needs of every procedure the model range of the Morcellator consist of instruments with three different diameters. They are available in 12, 15 and 20 mm versions. By carefully composed and aligned instruments and accessories the system as a whole delivers excellent results at morcellation and guarantees for maximum safety at operation. Ref.5139 Protection Sleeve, Ø 20 mm Ref.5138 Protection Sleeve, Ø 15 mm Ref.5137 Protection Sleeve, Ø 12 mm Ref.5153 Obturator, Ø 20 mm Tissue Positioner To prevent tissue pieces from rotating at morcellation, the Protection Sleeves are equipped with a so called Tissue Positioner. The Tissue Positioner acts also as a guiding element at morcellation. Ref.5152 Obturator, Ø 15 mm Ref.5151 Obturator, Ø 12 mm Ref.5156 Cutting tube Ø 20 mm Ref.5155 Cutting tube Ø 15 mm Ref.5154 Cutting tube Ø 12 mm 4 Cutting tube (Blade) The high-tech cutting tube manufactured by Nouvag AG, fulfills all requirements of Laparoscopic Hysterectomy as well as Myomenukleation. A high class refinement of the blade of the cutting tube enables multiple use with consistent cutting effect, without having to resharpen the blade. Drive train and seals + Seal holder + + Ref.:5135 Ref.:5166 Cross seal for all cutting tube diameters. 10 piece per packaging unit Membrane seal for all cutting tube diameters. 10 piece per packaging unit Membrane screw = Ref.5163 Gear unit with seal unit incl. seals and locking wrench. The motor speed is transmitted through the gear unit to the cutting tube at the appropriate ratio. ◄ Seal unit Ref.5183 The ergonomic handle that is slipped onto the gear unit protects the operator from excess heat of the motor and the gear unit. Ref.2090 Electronic motor 21 Autoclavable brushless electronic motor with a 3 meter cord delivers adequate torque, while running smooth and consistent. 5 Morcellator system chart Option 1 Obturator Protection Sleeve Gear unit Seal unit Cutting tube Control unit Handle Motor Pedal Option 2 Trocar Sleeve Motor plug Pedal plug to pedal to motor Gear unit Cutting tube Seal unit Obturator Handle Motor Option 3 Myoma drill Trocar Sleeve 6 Grasping forcep Extensions Trocars Ref.5142 Trocar Sleeve Ø 15 mm Ref.5141 Trocar Sleeve Ø 12 mm Myoma removals Ref.5193 Myoma drill Ø 10 mm Grasping forceps Claw forceps, Ø 10 mm/420 mm Tenaculum forceps, Ø 10 mm/420 mm Tenaculum forceps, Ø 5 mm/420 mm Ref. 5195 Ref. 5196 Ref. 5194 Flush opening Ø 13.5 mm Ø 15.0 mm Tenaculum forceps, Ø 13.5 mm, Ø 15.0 mm/420 mm Ref. 5192 Sterilization tray Stericase, 465 x 280 x 100 mm Ref. 4113 For the steilization and the storage of sterilizable instruments and accessories. Silicone mat, 450 x 270 mm Ref. 4126 Nonslip nubby mat to prevent sterilizable items from rolling around. 7 Scope of delivery, extensions and spare parts TCM 3000 BL Morcellator set, Ref. 3287 Ref. Description 3281 TCM 3000 BL MORCELLATOR control unit, power cord (Cord is supplied country specific) PU * 1 1507 Vario pedal, IPX8, 3 m of connecting cable 1 2090 Electronic motor 21, motor cable 3 m 1 5163 Transmission unit 1 5183 Handle 1 31946 Operation manual on CD-ROM 1 1974 Spray nozzle for NouClean Spray for maintenance and care of electronic motor 21 1 1928 Spray nozzle for NouClean Spray for maintenance and care of Transmission Unit 1 * PU: Packaging unit Extensions Ref. Description PU * 5137 Protection Sleeve, Ø 12 mm 1 5138 Protection Sleeve, Ø 15 mm 1 5139 Protection Sleeve, Ø 20 mm 1 5151 Obturator, Ø 12 mm 1 5152 Obturator, Ø 15 mm 1 5153 Obturator, Ø 20 mm 1 5154 Cutting Tube, Ø 12 mm 1 5155 Cutting Tube, Ø 15 mm 1 5156 Cutting Tube, Ø 20 mm 1 5141 Trocar Sleeve for instruments Ø 12 mm 1 5142 Trocar Sleeve for instruments Ø 15 mm 1 5193 Myoma Drill Ø 10 mm 1 5192 Grasping forceps, Tenaculum forceps, Ø 13.5 mm/Ø 15.0 mm, length 420 mm 1 5194 Grasping forceps, Tenaculum forceps, Ø 5 mm, length 420 mm 1 5195 Grasping forceps, Claw forceps, Ø 10 mm, length 420 mm 1 5196 Grasping forceps, Tenaculum forceps, Ø 10 mm, length 420 mm 1 4113 Stericase, Aluminium, 465 x 280 x 100 mm 1 4126 Non slip silicone mat with nubs for Stericase, 450 x 270 mm 1 1984 In line with regulations pertaining to hazardous materials, NouClean Spray may not be delivered together with the control unit and must be ordered separately. It can be ordered in every Service Center worldwide. 1 * PU: Packaging unit Spare parts Ref. Description PU * 5136 Spare Seal Unit 5135 Cross seal for all diameters of Cutting Tubes 10 5166 Membrane Seal for all diameters of Cutting Tubes 10 5177 Gaskets for Trocar Sleeve for instruments Ø 12 mm and 15 mm 10 5180 O-Ring for Trocar Sleeves Ø 12 mm and 15 mm 1 10 * PU: Packaging unit Nouvag AG · Postfach 180 · St.Gallerstr. 23–25 · CH-9403 Goldach Tel +41 (0)71 846 66 00 · Fax +41 (0)71 846 66 70 [email protected] · www.nouvag.com 8 Nouvag GmbH · Schulthaißstr. 15 · D-78462 Konstanz Tel +49 (0)7531 1290-0 · Fax +49 (0)7531 1290-12 [email protected] · www.nouvag.com