Cylindrical fuse-link
Transcription
Cylindrical fuse-link
Technical data Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics Body material Material of contact parts 400 V AC, 500 V AC, 690 V AC CH 8 1-25 A/400 V CH 10 0,5-16 A/500 V, 20-32 A/400 V CH 14 2-25 A/690 V, 32-50 A/500 V CH 22 16-40 A/690 V (50 A/690 V aM), 50-100 A/500 V 50 Hz CH 8 50 kA CH 10 100 kA CH 14 2-25 A/80 kA, 32-50 A/120 kA CH 22 16-40 A/80 kA (50 A/80 kA aM), 50-100 A/120 kA gG, aM ceramic CuZn28, gal.Ag d size e f 14 x 51 22 x 58 3,8 3,8 7,5 7,5 øc r d With striker pin b b size a b max. c d min. r 8 x 32 10 x 38 14 x 51 22 x 58 31,5±0,5 38,0±0,6 51,0+0,6/-1 58,0+0,1 6,7 10,5 13,8 16,2 8,5±0,1 10,3±0,1 14,3±0,1 22,2±0,1 4 6 7,5 11 1±0,5 1,5±0,5 ±1 ±1 a tv (s) 10 Prearcing time (s) Time current characteristics I/t, gG CH8 4 4A 6A 8A 10A 12A 16A 20A 25A 2A 6 4 2 10 3 6 4 2 2 C 10 6 4 2 10 1 6 4 2 10 0 6 4 2 -1 10 6 4 2 -2 10 4 6 10 1 2 4 6 10 2 2 4 6 10 Prospective current (A) 3 2 Ip (A) 471 Technical data 4 2I 2I 25 20 K K 6 4 16 2 Io (A) 10 Maximum value of current (A) Cut-off current characteristics CH8 12 10 8 6 4 2 10 3 2 6 1 4 10 In (A) 2 2 6 4 2 10 1 10 1 4 2 6 10 2 2 4 6 10 3 2 4 6 10 4 2 Prospective current (A) 10 I2t (A2s) Melting energy characteristics I2t CH8 4 10 5 Ip (A) 5 6 4 2 10 4 6 4 2 10 25A 3 20A 6 4 C 16A 12A 2 10 2 10A 6 4 10 8A 6A 4A -1 10 2 10 0 1 -2 10 6 4 2A -3 10 2 10 1A 0 -4 10 6 4 2 -1 10 4 6 10 1 2 4 6 10 2 2 4 6 10 3 2 4 6 Prospective current (A) 472 4 10 Ip (A) 2 Technical data 10 25A 4A 6A 8A 10A 12A 16A 20A 32A 2A 4 6 4 I2t (A2t) Prearcing time (s) Time current characteristics I/t, gG CH10 2 10 3 6 4 2 10 2 6 4 2 10 1 6 4 2 10 0 6 4 2 -1 10 6 4 2 -2 10 4 6 10 1 2 4 10 6 2 4 2 10 6 3 Prospective current (A) C 4 K 32 25 20 16 12 10 68 4 2I 2I K 6 2 Io (A) 10 Maximum value of current (A) Cut-off current characteristics CH10 2 Ip (A) 4 2 10 3 2 6 1 4 0,5 2 2 In (A) 10 6 4 2 10 1 10 1 2 4 6 10 2 2 4 6 10 3 2 4 6 10 4 2 Prospective current (A) 4 10 5 Ip (A) 473 Melting energy characteristics I2t CH10 I2t (A2s) Technical data Prospective current (A) Time current characteristics I/t, gG CH14 4 t (s) 10 2A 4A 32A 16A 20A 25A 40A 50A 6A 8A 10A 12A 6 4 Prearcing time (s) 2 3 10 6 4 2 2 C 10 6 4 2 1 10 6 4 2 0 10 6 4 2 -1 10 6 4 2 -2 10 4 6 1 10 2 4 6 2 10 2 4 6 3 10 Prospective current (A) 474 2 Ip (A) Ip (A) Technical data 50 40 32 25 20 16 12 108 6 4 K 4 2I K 2I 10 2 Io (A) 2 Maximum value of current (A) Cut-off current characteristics CH14 6 4 2 10 2 3 6 4 2 2 In (A) 10 6 4 2 10 1 10 1 2 4 6 10 2 2 4 6 10 3 2 4 6 10 4 2 5 Ip (A) C Melting energy characteristics I2t CH14 10 I2t (A2s) Prospective current (A) 4 Prospective current (A) Ip (A) 475 Technical data tv (s) 10 Prearcing time (s) Time current characteristics I/t, gG CH22 50A 80A 25A 16A 20A 32A 40A 63A 100A 4 6 4 2 10 3 6 4 2 10 2 6 4 2 10 1 6 4 2 10 0 6 4 2 -1 10 6 4 2 -2 10 4 6 10 1 2 4 10 6 2 4 2 10 6 3 Prospective current (A) 10 2 K 100 80 60 50 40 32 K 2I 10 4 2I Io (A) 4 2 C 5 6 Maximum value of current (A) Cut-off current characteristics CH22 2 Ip (A) 6 25 20 16 4 10 In (A) 2 3 6 4 2 10 2 10 1 2 4 6 10 2 2 4 6 10 3 2 4 6 10 4 2 Prospective current (A) 476 4 10 Ip (A) 5 Melting energy characteristics I2t CH22 I2t (A2s) Technical data Prospective current (A) Time current characteristics I/t, aM CH10, 14, 22 Ip (A) 1000 0,5 1 2 4 6 50 80 12 20 32 8 10 16 25 40 63 100 C 100 Prearcing time (s) 10 1 0.1 0.01 0.001 1 10 100 1. 000 10. 000 Prospective current (A) 477 Technical data Fuse disconnectors for cylindrical fuse-links EFD Technical data EFD Number of poles EFD 8 EFD 10 EFD CC CH 8x32 CH 10x38 Class CC IEC IEC UL UL Without indicator/LED indicator/NEON indicator 1p, 1p+N, 2p, 3p, 3p+N 1p, 2p, 3p Rated operational voltage Ue 400V a.c. 690V a.c. 20A 32A 10A gG Fuse type Versions Rated operational current Ie Maximum rated current of fuselinks 690V 500V 400V Rated frequency Rated short-time withstand current Icw Conventional free air thermal current Ith Rated conditional short-circuit current Rated insulation voltage Ui Rated imp. withstand voltage Uimp Overvoltage category (according to Table H.1 in IEC 60947-1 and according to IEC 60099-1) Max power dissipation of the fuse-link (W) LED indicator operating range NEON indicator operating range C Utilization category Operational performance (cycles with current) Operational performance (cycles without current) Humidity Operating ambient temperature Store ambient temperature Degree of protection (IEC 60529) Terminal capacity Screw Torque Mounting on EN 60715 rail Sealing posibility Standards - fuse links Standards - fuse disconnectors/ fuse holders Test reports Certificates 478 600V a.c./d.c. 30A 600V a.c./d.c. 30A 25A gG 16A aM 32A gG EFD 14 CH 14x51 IEC 1p, 1p+N, 2p, 3p, 3p+N 690V a.c. 50A 25A gG 25A aM 50A gG EFD 22 CH 22x58 UL IEC Without indicator / LED indicator 1p, 2p, 3p 600V a.c./d.c. 50A 50A aM 1p, 1p+N, 2p, 3p, 3p+N 690V a.c. 100A 50A gG 50A aM 100A gG EFD J30 Class J, size J30 UL UL 1p, 2p, 3p 600V a.c./d.c. 600V a.c./d.c. 100A 30A 20A gG 10A aM 50Hz 240A 50Hz 300A/1s 60Hz 60Hz 50Hz 600A/1s 50A 60Hz 50Hz 1200A/1s 100A 60Hz 60Hz 50kA 100kA/400V 100kA 200kA 100kA 200kA 690V 8kV III gG: 120kA/500V (100A gG) aM: 50kA/400V (100A aM) 690V 8kV III 100kA 400V 8kV III gG: 120kA/500V (50A gG) aM: 50kA/400V (50A aM) 690V 8kV III 3W gG: 5W aM: 3W 50V-690V a.c. gG: 2,5W gG: 3W aM: 0,9W aM: 1,2W 50V-690V a.c. 50V - 600V a.c. 80V - 600V d.c. 100V-750V a.c. AC-22B 100V-750V a.c. AC-22B 300 300 AC-22B at 690V/50A 300 1700 1700 1700 -5°C ... +40°C -25°C ... +55°C IP 20 IP 20 1-25mm2 1-25mm2 PZ M5 2Nm PZ M5 2Nm IEC/EN 60269-2 IEC/EN 60269-2 Do not operate under load AWG 18-8 solid&stranded Cu only PZ M5 PZ M5 2Nm; 17,7 lb-in IEC/EN 60269-2 UL 248-4 IEC/EN 60269-2 UL 4248-1 UL 4248-4 UL 486E CSA C22.2 No.65 IEC 60947-1 IEC 60947-3 CCA/CB CCA/CB UL URUS C UL ULUS C 100A aM 50V - 600V a.c. 80V - 600V d.c. Do not operate AC-21B at 690V/100A under load 300 CCA/CB 6W 50V - 600V a.c. 80V - 600V d.c. Do not operate under load 1700 -5°C ... +40°C -25°C ... +55°C IP 20 1,5-35mm2 AWG 16-6 rigid or flexible solid&stranded Cu only PZ M5 PZ M5 2,5-3Nm 2Nm; 17,7 lb-in 35mm rail ON and OFF IEC/EN 60269-2 IEC/EN 60269-2 IEC 60947-1 IEC 60947-3 gG: 9,5W aM: 7W 50V-690V a.c. -5°C ... +40°C -25°C ... +55°C IP 20 4-50mm2 rigid or flexible AWG 12-2 solid&stranded Cu only PZ M6 3Nm PZ M6 PZ M6 3Nm; 26,6 lb-in IEC/EN 60269-2 IEC/EN 60269-2 UL 248-8 IEC/EN 60269-2 UL 4248-1 UL 486E IEC 60947-1 IEC 60947-3 UL 4248-1 UL 486E CSA C22.2 No. 65 CSA C22.2 No. 14 UL URUS CCA/CB UL 4248-1 UL 4248-8 UL 486E CSA C22.2 No. 65 CSA C22.2 No. 14 UL UL C US C UL URUS C Technical data Technical data EFD EFD 8 CH 8x32 IEC Fuse type Derating factor of current In for different ambient temperatures Derating factor of current In for side by side mounting fuse holders (nr. of poles) EFD 10 CH 10x38 IEC UL EFD CC Class CC UL EFD 14 CH 14x51 IEC EFD 22 CH 22x58 UL 200 300 1 0,95 400 500 600 700 1-4 5-6 7-9 ≥10 0,9 0,8 0,7 0,5 1 0,8 0,7 0,6 IEC UL EFD J30 Class J, size J30 UL Fuse disconnector EFD 8, EFD 10 type dimension B EFD 8, 10 1p 17,5 EFD 8, 10 1p+N 35 EFD 8, 10 2p 35 EFD 8, 10 3p 52,5 EFD 8, 10 3p+N 70 Fuse disconnector EFD CC type dimension B EFD CC 1p 17,5 EFD CC 2p 35 EFD CC 3p 52,5 Version with adapter Fuse disconnector EFD 22 & EFD J30 type dimension B EFD 22, J30 1p 35,6 EFD 22 1p+N 71,2 EFD 22, J30 2p 71,2 EFD 22, J30 3p 106,8 EFD 22 3p+N 142,4 C Fuse disconnector EFD 14 type dimension B EFD 14 1p 27 EFD 14 1p+N 54 EFD 14 2p 54 EFD 14 3p 81 EFD 14 3p+N 108 479 Technical data Auxiliary switch EFD PS VLC 14 PS VLC 22 65.2 10.6 65.2 56.8 10.6 56.8 9 5 9 90 45 45 90 5 43.4 43.4 49.7 49.7 54.7 54.7 PS EFD 14 PS EFD 22 Fuse disconnectors for cylindrical fuse-links PCF Technical data PCF PCF 8 CH 8x32 IEC Fuse type Versions Number of poles 400V a.c. C Rated frequency Rated short-time withstand current Icw Rated conditional short-circuit current Rated insulation voltage Ui Rated imp. withstand voltage Uimp Overvoltage category Max power dissipation of the fuse-link (W) LED indicator operating range Utilization category Operational performance (cycles with current) Operational performance (cycles without current) Humidity Operating ambient temperature Store ambient temperature Degree of protection (IEC 60529) Terminal capacity Screw Torque Mounting on EN 60715 rail Sealing posibility Standards - fuse links Standards - fuse disconnectors/fuse holders Test reports Certificates 480 690V a.c. 20A 690V 500V 400V PCF CC Class CC UL IEC UL Without indicator / LED indicator 1p, 1p+N, 2p, 3p, 3p+N Rated operational voltage Ue Rated operational current Ie Maximum rated current of fuselinks PCF 10 CH 10x38 32A 10A gG 25A gG, 16A aM 20A gG, 10A aM 32A gG 50Hz 50Hz 240A 300A 50kA 100kA 400V 690V 4kV 4kV III III gG: 2,5W / aM: 0,9W gG: 3W / aM: 1,2W 50V-690V a.c. AC-22B AC-22B 300 300 1700 1700 90% at 20°C -5°C ... +40°C -25°C ... +55°C IP 20 IP 20 0,5-10mm2, Double connection PZ M4 PZ M4 1,2Nm 1,2Nm IEC/EN 60269-2 IEC 60947-1, IEC 60947-3 Int. CCA/CB 1p, 2p, 3p 600V a.c./d.c. 600V a.c./d.c. 30A 30A 60Hz 60Hz 200kA 200kA 50V-600V a.c., 80V-600V d.c. Do not operate under load 20-10 stranded, Cu only 20-10 solid&stranded, Cu only PZ M4 PZ M4 1,2Nm 1,2Nm 35mm rail ON and OFF UL 248-4, IEC/EN 60269-2 UL 4248-1 UL 4248-1, UL 4248-4 UL Int UR C US Technical data Technical data PCF PCF 8 CH 8x32 IEC Fuse type Derating factor of current In for different ambient temperatures Derating factor of current In for side by side mounting fuse holders (nr. of poles) PCF 10 CH 10x38 IEC UL 200 300 1 0,95 400 500 600 700 1-4 5-6 7-9 ≥10 0,9 0,8 0,7 0,5 1 0,8 0,7 0,6 PCF CC Class CC UL 64 B 43,8 B 83,3 64,4 64,4 45,1 45,1 43,8 Fuse disconnector PCF 8, PCF 10, PCF CC type dimension B PCF 8, 10, CC 1p 17,8 PCF 8, 10 1p+N 17,8 PCF 8, 10, CC 2p 35,6 PCF 8, 10, CC 3p 53,4 PCF 8, 10 3p+N 53,4 83,3 64 6,8 C 6,8 Auxiliary switch PS PCF 78.7 64.4 83.3 52 12.1 9 43.7 45 43.7 52 49.6 78.7 64.4 83.3 45 6 49.6 6 10.3 9 12.1 10.3 481 C Technical data 482