Cylindrical fuse-link

Transcription

Cylindrical fuse-link
Technical data
Cylindrical fuse-link
Technical data
Rated voltage
Rated current
Rated frequency
Rated breaking capacity
Characteristics
Body material
Material of contact parts
400 V AC, 500 V AC, 690 V AC
CH 8
1-25 A/400 V
CH 10
0,5-16 A/500 V, 20-32 A/400 V
CH 14
2-25 A/690 V, 32-50 A/500 V
CH 22
16-40 A/690 V (50 A/690 V aM), 50-100 A/500 V
50 Hz
CH 8
50 kA
CH 10
100 kA
CH 14
2-25 A/80 kA, 32-50 A/120 kA
CH 22
16-40 A/80 kA (50 A/80 kA aM), 50-100 A/120 kA
gG, aM
ceramic
CuZn28, gal.Ag
d
size
e
f
14 x 51
22 x 58
3,8
3,8
7,5
7,5
øc
r
d
With striker pin
b
b
size
a
b max.
c
d min.
r
8 x 32
10 x 38
14 x 51
22 x 58
31,5±0,5
38,0±0,6
51,0+0,6/-1
58,0+0,1
6,7
10,5
13,8
16,2
8,5±0,1
10,3±0,1
14,3±0,1
22,2±0,1
4
6
7,5
11
1±0,5
1,5±0,5
±1
±1
a
tv (s)
10
Prearcing time (s)
Time current characteristics
I/t, gG
CH8
4
4A 6A 8A 10A 12A 16A 20A 25A
2A
6
4
2
10
3
6
4
2
2
C
10
6
4
2
10
1
6
4
2
10
0
6
4
2
-1
10
6
4
2
-2
10
4
6
10
1
2
4
6
10
2
2
4
6
10
Prospective current (A)
3
2
Ip (A)
471
Technical data
4
2I
2I
25
20
K
K
6
4
16
2
Io (A)
10
Maximum value of current (A)
Cut-off current
characteristics
CH8
12
10
8
6
4
2
10
3
2
6
1
4
10
In (A)
2
2
6
4
2
10
1
10
1
4
2
6
10
2
2
4
6
10
3
2
4
6
10
4
2
Prospective current (A)
10
I2t (A2s)
Melting energy
characteristics I2t
CH8
4
10
5
Ip (A)
5
6
4
2
10
4
6
4
2
10
25A
3
20A
6
4
C
16A
12A
2
10
2
10A
6
4
10
8A
6A
4A
-1
10
2
10
0
1
-2
10
6
4
2A
-3
10
2
10
1A
0
-4
10
6
4
2
-1
10
4
6
10
1
2
4
6
10
2
2
4
6
10
3
2
4
6
Prospective current (A)
472
4
10
Ip (A)
2
Technical data
10
25A
4A 6A 8A 10A 12A 16A 20A 32A
2A
4
6
4
I2t (A2t)
Prearcing time (s)
Time current characteristics
I/t, gG
CH10
2
10
3
6
4
2
10
2
6
4
2
10
1
6
4
2
10
0
6
4
2
-1
10
6
4
2
-2
10
4
6
10
1
2
4
10
6
2
4
2
10
6
3
Prospective current (A)
C
4
K
32
25
20
16
12
10
68
4
2I
2I
K
6
2
Io (A)
10
Maximum value of current (A)
Cut-off current
characteristics
CH10
2
Ip (A)
4
2
10
3
2
6
1
4
0,5
2
2
In (A)
10
6
4
2
10
1
10
1
2
4
6
10
2
2
4
6
10
3
2
4
6
10
4
2
Prospective current (A)
4
10
5
Ip (A)
473
Melting energy
characteristics I2t
CH10
I2t (A2s)
Technical data
Prospective current (A)
Time current characteristics
I/t, gG
CH14
4
t (s)
10
2A
4A
32A
16A 20A 25A 40A 50A
6A 8A 10A 12A
6
4
Prearcing time (s)
2
3
10
6
4
2
2
C
10
6
4
2
1
10
6
4
2
0
10
6
4
2
-1
10
6
4
2
-2
10
4
6
1
10
2
4
6
2
10
2
4
6
3
10
Prospective current (A)
474
2
Ip (A)
Ip (A)
Technical data
50
40
32
25
20
16
12
108
6
4
K
4
2I
K
2I
10
2
Io (A)
2
Maximum value of current (A)
Cut-off current
characteristics
CH14
6
4
2
10
2
3
6
4
2
2
In (A)
10
6
4
2
10
1
10
1
2
4
6
10
2
2
4
6
10
3
2
4
6
10
4
2
5
Ip (A)
C
Melting energy
characteristics I2t
CH14
10
I2t (A2s)
Prospective current (A)
4
Prospective current (A)
Ip (A)
475
Technical data
tv (s)
10
Prearcing time (s)
Time current characteristics
I/t, gG
CH22
50A 80A
25A
16A 20A 32A 40A 63A 100A
4
6
4
2
10
3
6
4
2
10
2
6
4
2
10
1
6
4
2
10
0
6
4
2
-1
10
6
4
2
-2
10
4
6
10
1
2
4
10
6
2
4
2
10
6
3
Prospective current (A)
10
2
K
100
80
60
50
40
32
K
2I
10
4
2I
Io (A)
4
2
C
5
6
Maximum value of current (A)
Cut-off current
characteristics
CH22
2
Ip (A)
6
25
20
16
4
10
In (A)
2
3
6
4
2
10
2
10
1
2
4
6
10
2
2
4
6
10
3
2
4
6
10
4
2
Prospective current (A)
476
4
10
Ip (A)
5
Melting energy
characteristics I2t
CH22
I2t (A2s)
Technical data
Prospective current (A)
Time current characteristics
I/t, aM
CH10, 14, 22
Ip (A)
1000
0,5
1
2
4
6
50 80
12 20 32
8 10 16 25 40 63 100
C
100
Prearcing time (s)
10
1
0.1
0.01
0.001
1
10
100
1. 000
10. 000
Prospective current (A)
477
Technical data
Fuse disconnectors for cylindrical fuse-links EFD
Technical data EFD
Number of poles
EFD 8
EFD 10
EFD CC
CH 8x32
CH 10x38
Class CC
IEC
IEC
UL
UL
Without indicator/LED
indicator/NEON indicator
1p, 1p+N, 2p, 3p, 3p+N
1p, 2p, 3p
Rated operational voltage Ue
400V a.c.
690V a.c.
20A
32A
10A gG
Fuse type
Versions
Rated operational current Ie
Maximum rated current of fuselinks
690V
500V
400V
Rated frequency
Rated short-time withstand current Icw
Conventional free air thermal
current Ith
Rated conditional short-circuit
current
Rated insulation voltage Ui
Rated imp. withstand voltage Uimp
Overvoltage category (according to Table H.1
in IEC 60947-1 and according to IEC 60099-1)
Max power dissipation of the fuse-link (W)
LED indicator operating range
NEON indicator operating range
C
Utilization category
Operational performance (cycles
with current)
Operational performance (cycles without current)
Humidity
Operating ambient temperature
Store ambient temperature
Degree of protection (IEC 60529)
Terminal capacity
Screw
Torque
Mounting on EN 60715 rail
Sealing posibility
Standards - fuse links
Standards - fuse disconnectors/
fuse holders
Test reports
Certificates
478
600V
a.c./d.c.
30A
600V
a.c./d.c.
30A
25A gG
16A aM
32A gG
EFD 14
CH 14x51
IEC
1p, 1p+N, 2p,
3p, 3p+N
690V a.c.
50A
25A gG
25A aM
50A gG
EFD 22
CH 22x58
UL
IEC
Without indicator / LED indicator
1p, 2p, 3p
600V
a.c./d.c.
50A
50A aM
1p, 1p+N, 2p, 3p,
3p+N
690V a.c.
100A
50A gG
50A aM
100A gG
EFD J30
Class J, size J30
UL
UL
1p, 2p, 3p
600V a.c./d.c.
600V a.c./d.c.
100A
30A
20A gG
10A aM
50Hz
240A
50Hz
300A/1s
60Hz
60Hz
50Hz
600A/1s
50A
60Hz
50Hz
1200A/1s
100A
60Hz
60Hz
50kA
100kA/400V
100kA
200kA
100kA
200kA
690V
8kV
III
gG: 120kA/500V
(100A gG)
aM: 50kA/400V
(100A aM)
690V
8kV
III
100kA
400V
8kV
III
gG: 120kA/500V
(50A gG)
aM: 50kA/400V
(50A aM)
690V
8kV
III
3W
gG: 5W
aM: 3W
50V-690V a.c.
gG: 2,5W
gG: 3W
aM: 0,9W
aM: 1,2W
50V-690V a.c.
50V - 600V a.c.
80V - 600V d.c.
100V-750V
a.c.
AC-22B
100V-750V
a.c.
AC-22B
300
300
AC-22B at
690V/50A
300
1700
1700
1700
-5°C ... +40°C
-25°C ... +55°C
IP 20
IP 20
1-25mm2
1-25mm2
PZ M5
2Nm
PZ M5
2Nm
IEC/EN
60269-2
IEC/EN
60269-2
Do not operate under
load
AWG 18-8
solid&stranded
Cu only
PZ M5
PZ M5
2Nm; 17,7 lb-in
IEC/EN
60269-2
UL 248-4
IEC/EN
60269-2
UL 4248-1
UL 4248-4
UL 486E
CSA C22.2 No.65
IEC 60947-1
IEC 60947-3
CCA/CB
CCA/CB
UL
URUS
C
UL
ULUS
C
100A aM
50V - 600V a.c.
80V - 600V d.c.
Do not operate AC-21B at 690V/100A
under load
300
CCA/CB
6W
50V - 600V a.c.
80V - 600V d.c.
Do not operate under load
1700
-5°C ... +40°C
-25°C ... +55°C
IP 20
1,5-35mm2
AWG 16-6
rigid or flexible solid&stranded
Cu only
PZ M5
PZ M5
2,5-3Nm
2Nm; 17,7
lb-in
35mm rail
ON and OFF
IEC/EN 60269-2
IEC/EN
60269-2
IEC 60947-1
IEC 60947-3
gG: 9,5W
aM: 7W
50V-690V a.c.
-5°C ... +40°C
-25°C ... +55°C
IP 20
4-50mm2
rigid or flexible
AWG 12-2 solid&stranded
Cu only
PZ M6
3Nm
PZ M6
PZ M6
3Nm; 26,6 lb-in
IEC/EN 60269-2
IEC/EN 60269-2
UL 248-8
IEC/EN 60269-2
UL 4248-1
UL 486E
IEC 60947-1
IEC 60947-3
UL 4248-1
UL 486E
CSA C22.2 No. 65
CSA C22.2 No. 14
UL
URUS
CCA/CB
UL 4248-1
UL 4248-8
UL 486E
CSA C22.2 No. 65
CSA C22.2 No. 14
UL
UL
C US
C
UL
URUS
C
Technical data
Technical data EFD
EFD 8
CH 8x32
IEC
Fuse type
Derating factor of current In for
different ambient temperatures
Derating factor of current In for side
by side mounting fuse holders (nr.
of poles)
EFD 10
CH 10x38
IEC
UL
EFD CC
Class CC
UL
EFD 14
CH 14x51
IEC
EFD 22
CH 22x58
UL
200
300
1
0,95
400
500
600
700
1-4
5-6
7-9
≥10
0,9
0,8
0,7
0,5
1
0,8
0,7
0,6
IEC
UL
EFD J30
Class J, size J30
UL
Fuse disconnector EFD 8, EFD 10
type
dimension
B
EFD 8, 10 1p
17,5
EFD 8, 10 1p+N
35
EFD 8, 10 2p
35
EFD 8, 10 3p
52,5
EFD 8, 10 3p+N
70
Fuse disconnector EFD CC
type
dimension
B
EFD CC 1p
17,5
EFD CC 2p
35
EFD CC 3p
52,5
Version with adapter
Fuse disconnector EFD 22 & EFD J30
type
dimension
B
EFD 22, J30 1p
35,6
EFD 22 1p+N
71,2
EFD 22, J30 2p
71,2
EFD 22, J30 3p
106,8
EFD 22 3p+N
142,4
C
Fuse disconnector EFD 14
type
dimension
B
EFD 14 1p
27
EFD 14 1p+N
54
EFD 14 2p
54
EFD 14 3p
81
EFD 14 3p+N
108
479
Technical data
Auxiliary switch EFD
PS VLC 14
PS VLC 22
65.2
10.6
65.2
56.8
10.6
56.8
9
5
9
90
45
45
90
5
43.4
43.4
49.7
49.7
54.7
54.7
PS EFD 14
PS EFD 22
Fuse disconnectors for cylindrical fuse-links PCF
Technical data PCF
PCF 8
CH 8x32
IEC
Fuse type
Versions
Number of poles
400V a.c.
C
Rated frequency
Rated short-time withstand current Icw
Rated conditional short-circuit current
Rated insulation voltage Ui
Rated imp. withstand voltage Uimp
Overvoltage category
Max power dissipation of the fuse-link (W)
LED indicator operating range
Utilization category
Operational performance (cycles with current)
Operational performance (cycles without current)
Humidity
Operating ambient temperature
Store ambient temperature
Degree of protection (IEC 60529)
Terminal capacity
Screw
Torque
Mounting on EN 60715 rail
Sealing posibility
Standards - fuse links
Standards - fuse disconnectors/fuse holders
Test reports
Certificates
480
690V a.c.
20A
690V
500V
400V
PCF CC
Class CC
UL
IEC
UL
Without indicator / LED indicator
1p, 1p+N, 2p, 3p, 3p+N
Rated operational voltage Ue
Rated operational current Ie
Maximum rated current of fuselinks
PCF 10
CH 10x38
32A
10A gG
25A gG, 16A aM
20A gG, 10A aM
32A gG
50Hz
50Hz
240A
300A
50kA
100kA
400V
690V
4kV
4kV
III
III
gG: 2,5W / aM: 0,9W
gG: 3W / aM: 1,2W
50V-690V a.c.
AC-22B
AC-22B
300
300
1700
1700
90% at 20°C
-5°C ... +40°C
-25°C ... +55°C
IP 20
IP 20
0,5-10mm2, Double connection
PZ M4
PZ M4
1,2Nm
1,2Nm
IEC/EN 60269-2
IEC 60947-1, IEC 60947-3
Int.
CCA/CB
1p, 2p, 3p
600V a.c./d.c.
600V a.c./d.c.
30A
30A
60Hz
60Hz
200kA
200kA
50V-600V a.c., 80V-600V d.c.
Do not operate under load
20-10 stranded, Cu only 20-10 solid&stranded, Cu only
PZ M4
PZ M4
1,2Nm
1,2Nm
35mm rail
ON and OFF
UL 248-4, IEC/EN 60269-2
UL 4248-1
UL 4248-1, UL 4248-4
UL
Int
UR
C US
Technical data
Technical data PCF
PCF 8
CH 8x32
IEC
Fuse type
Derating factor of current In for
different ambient temperatures
Derating factor of current In for side
by side mounting fuse holders (nr.
of poles)
PCF 10
CH 10x38
IEC
UL
200
300
1
0,95
400
500
600
700
1-4
5-6
7-9
≥10
0,9
0,8
0,7
0,5
1
0,8
0,7
0,6
PCF CC
Class CC
UL
64
B
43,8
B
83,3
64,4
64,4
45,1
45,1
43,8
Fuse disconnector PCF 8, PCF 10, PCF CC
type
dimension
B
PCF 8, 10, CC 1p
17,8
PCF 8, 10 1p+N
17,8
PCF 8, 10, CC 2p
35,6
PCF 8, 10, CC 3p
53,4
PCF 8, 10 3p+N
53,4
83,3
64
6,8
C
6,8
Auxiliary switch PS PCF
78.7
64.4
83.3
52
12.1
9
43.7
45
43.7
52
49.6
78.7
64.4
83.3
45
6
49.6
6
10.3
9
12.1
10.3
481
C
Technical data
482