Installation Accessories and Applications

Transcription

Installation Accessories and Applications
SECTION DIRECTORY
INSTALLATION
ACCESSORIES
Installation Accessories and Applications
Introduction...................................................................................................................................................W-IA-2
Window Attachment Options............................................................................................................W-IA-4
Subsill....................................................................................................................................................W-IA-6
Exterior Mullions..................................................................................................................................W-IA-8
Mullion Cover Application................................................................................................................W-IA-10
Mullion Reinforcements....................................................................................................................W-IA-12
Reinforcing Mullion Application......................................................................................................W-IA-13
Expansion Mullion Cover Application.............................................................................................W-IA-14
Mullion Considerations.....................................................................................................................W-IA-16
Commercial Structural Receptor Mullions......................................................................................W-IA-17
Exterior Trim Applications.................................................................................................................W-IA-22
Frame Expansion Application..........................................................................................................W-IA-25
EnduraClad® Exterior Trim...............................................................................................................W-IA-28
EnduraClad® Exterior Trim Applications........................................................................................W-IA-30
Commercial Replacement Accessories..........................................................................................W-IA-34
Break Metal.........................................................................................................................................W-IA-36
Wood Exterior Mullion Covers.........................................................................................................W-IA-39
Window and Door Subsills and Exterior Trim................................................................................W-IA-40
Interior Casings..................................................................................................................................W-IA-41
Interior Stools and Trim.....................................................................................................................W-IA-42
ReadyTrim...........................................................................................................................................W-IA-43
Interior Jamb Extensions..................................................................................................................W-IA-44
Interior Mullion Covers.....................................................................................................................W-IA-44
AZEK Trim Details
Custom Window Shapes..................................................................................................................W-IA-45
Exterior Surround Trim......................................................................................................................W-IA-46
Custom Door Shapes........................................................................................................................W-IA-47
2" Brickmould with Sill......................................................................................................................W-IA-48
Exterior Surround Trim......................................................................................................................W-IA-49
Flat Casing with Sill Nose and Crown.............................................................................................W-IA-50
Pocket Replacment
Exterior Pocket Installation...............................................................................................................W-IA-53
Interior Pocket Installation................................................................................................................W-IA-54
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-1
INTRODUCTION
INSTALLATION
ACCESSORIES
This section presents available installation accessories which, when used in conjunction with proper Pella installation procedures, will provide
for a robust installation for single or combination units. Window and door attachment accessories used for both clad and primed wood
exterior units are illustrated in this section.
Aside from attachment accessories, this section reviews accessories to meet the following requirements:
• Combination applications, such as mullion covers, expansion mullion covers, reinforcement mullions and bay and bow accessories.
• Interior casings and stools
• Subsills
• Traditional and flat trim
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-2
ATTACHMENT OPTIONS
INSTALLATION
ACCESSORIES
IN STALLAT IO N ACC E S S O R IE S
Indiv.
Part No.
Box
No.
Installation Fin
Head Drip Cap
Curved Head Drip Fin
Elliptical Head Drip Fin
Quarter Circle Head Drip Fin
Head Drip Flashing
Head Flashing
Receptor
Receptor Gasket
6" Installation Clip
8" Installation Clip
42G7
72GW
72Y5
72Y7
72Y6
72WA
72W8
72AK
—
5071
5071
0BLA
0BLB
—
—
—
0BMS
—
06Y1
0DA9
0635
0B51
T-Subframe Clip
3"-wide Smart Flash®
Installation Tape (150' rolls)
6"-wide Smart Flash®
Installation Tape (50' rolls)
5027
0DB0
850H0000
0CFV
850H0004
01FM
Accessory
72GW
72WA
72W8
72Y5
WO O D S I LL P LAT E S F O R C LAD W IND OWS
Indiv.
Part No.
Box
No.
2722
2772
0C79
—
Indiv.
Part No.
Box
No.
Clad / Wood Subsill
4049
0B13
Subsill Clip
7366
0B14
Replacement Sill Adaptor
70DK
—
Accessory
CM / AW Sill Plate
ProLine® Sill Plate
S U B S I LLS
Accessory
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-3
ATTACHMENT OPTIONS
INSTALLATION
ACCESSORIES
Installation Fin
Scale 6" = 1' 0"
Scale 3" = 1' 0"
H
SHIM AND LEVEL UNITS AS
REQUIRED
CONTINUOUS WOOD
BLOCKING, WOOD
TRIM, BACKER ROD AND
SEALANT BY OTHERS
J
S
Not to scale.
To determine window openings for typical installations, add 3/4" to frame
width and 3/4" to frame height.
• For large size units, out of plumb opening, and/or in masonry
construction, the need for additional jamb clearances should
be reviewed.
• Typical installation details and accessories are shown in the
Installation Details and Installation Accessories sections.
• Determine if unit performance meets design requirements. Unit
performance class and grade are in each product section.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-4
INSTALL ATION SYSTEMS
New Construc tion — Punched Opening
Clip Installation
FRAME
ROUGH OPENING
3/8"
[10]
INSTALLATION
ACCESSORIES
2 1/2"
[64]
FRAME
3/8"
[10]
ROUGH OPENING
HEAD
3/8"
[10]
FRAME
ROUGH OPENING
JAMB
SILL
H
To determine window openings for typical installations, add 3/4" to frame width and
3/4" to frame height.
• For large size units, out of plumb opening, and/or in masonry construction, the
need for additional jamb clearances should be reviewed.
• Typical installation details and accessories are shown in the Installation Details
and Installation Accessories sections.
• Determine if unit performance meets design requirements. Unit performance
class and grade are in each product section.
J
S
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-5
ATTACHMENT OPTION APPLICATIONS
Clad Wood Subsill
INSTALLATION
ACCESSORIES
Subsills are recommended for installations where recaulking
would be difficult or high weather exposure exists due to the
height or location of the building. The need for the subsill
weep system is increased where there are multiple units in a
given opening.
Note: The clad wood subsill is an open weep system. An interior air seal is
critical to the performance of this system. Also, DO NOT SEAL the exterior
frame expander to the opening.
Used with Pella clad windows.
Detail at right: Custom 0.05" (1.27) aluminum sill
flashing used with clad wood subsill.
Scale 3" = 1' 0"
• A continuous perimeter line of sealant is required on the interior with clad / wood subsill #4049.
• Where the aluminum comes into contact with the cement materials, apply protective coating to separate galvanically incompatible materials.
• The clad / wood subsill is a primed, preservative treated wood for use with Pella aluminum clad / wood windows.
• The aluminum frame expander covers the front edge of the subsill.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-6
ATTACHMENT OPTION APPLICATIONS
INSTALLATION
ACCESSORIES
L Receptor Application
Scale 6" = 1' 0"
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-7
EXTERIOR MULLIONS
INSTALLATION
ACCESSORIES
Bay/Bow Mullion Accessories
B AY AN D B O W M U LLIO N ACC E S S O RI ES
Bay Wedges
12° 45'
30°
45°
Mullion Covers
12° 45'
30°
45°
Jamb Covers
12° 45'/30º
45°
Indiv.
Part No.
Box
No.
33CX
33CW
34A3
0B19
0B20
0B21
Indiv. Part
No.
Box
No.
72A3
72A4
72A5
0B43
0B37
0C72
Indiv. Part
No.
47L2
47K4
See the Architectural Design Manual Bay/Bow section for cross sections of application.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-8
EXTERIOR MULLIONS
INSTALLATION
ACCESSORIES
Mullion Covers
MUL L ION COV E RS
Mullion Cover
A
(Frame to Frame)
B
(Overall Part
Dimension)
Part Number
Thickness (In.)
Standard (Direct)
0"
3/8
7217
0.047
1/2"
1/2"
7/8
736M
0.047
1"
1"
1-3/8
736N
0.047
1-1/2"
1-1/2"
1-7/8
736P
0.047
2"
2"
2-3/8
72A9
0.047
2-1/2"
2-1/2"
2-7/8
736T
0.047
3"
3"
3-3/8
736U
0.060
3-1/2"
3-1/2"
3-7/8
736V
0.060
4"
4"
4-3/8
736W
0.060
Custom
(Break Metal)
Min 5/8"
Max 12"
B = A + 3/8"
100 Mullion Cover
0.050
For all but direct mullion, dimension A is to inside of bends. Frame to Frame plus 1/4"
equals dimension to inside of bends.
A = B - 3/8"
3 1/2" Mullion Cover
3" Structure
Standard mull covers are extruded aluminum.
Standard EnduraClad
Mullion Covers
A
B
Break Metal
100 Mullion Cover
Structure
FRAME
RO
A = SPCL. 5/8" - 12"
[16 - 305]
A
FRAME
RO
B
B
1 1/2"
[38]
2"
[51]
2 1/2"
[64]
3/8"
[9]
7/8"
[22]
1 3/8"
[35]
1 7/8"
[47]
2 3/8"
[60]
2 7/8"
[73]
STANDARD
7217
1/2" Mullion Cover
736M
1" Mullion Cover
736N
1-1/2" Mullion Cover
736P
2" Mullion Cover
72A9
2-1/2" Mullion Cover
736T
3"
[76]
3 1/2"
[89]
4"
[102]
3 3/8"
[85]
3 7/8"
[98]
4 3/8"
[111]
3" Mullion Cover
736U
3-1/2" Mullion Cover
736V
4" Mullion Cover
736W
SPCL. 5/8" - 12"
[16 - 305]
5/16"
[8]
1"
[25]
1/2"
[13]
Break Metal
100 Mullion Cover
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-9
MULLION APPLICATIONS
Scale 6" = 1' 0"
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
SHIM AND
LEVEL UNITS AS
REQUIRED
CUSTOM BREAK METAL MULLION COVER
CONTINUOUS
WOOD
BLOCKING,
WOOD TRIM,
BACKER ROD
AND SEALANT BY
OTHERS
100 Mullion cover is fabricated from 0.050"
Aluminum for widths of 5/8" to 12" (16 305).
(Dimension A is to inside of bends. Frame to
Frame plus 1/4" equals dimension to inside
of bends.)
NOTE: APPLY CONTINUOUS BEAD OF SEALANT
TO INSIDE CORNERS OF MULLION COVER BEFORE
INSTALLING UNITS.
INSTALLATION
CLIPS #5071
@ 18" (457) O.
C. (REFER TO
PAGE (17) FOR
ADDITIONAL
SPACING
INFORMATION
90° MULLION COVER #4994
Use of installation fins #42G7 recommended
with 90° mullion.
CONTINUOUS
INSTALLATION
FINS #42G7
SHIM AND
LEVEL UNITS AS
REQUIRED
CONTINUOUS
WOOD
BLOCKING,
WOOD TRIM,
BACKER ROD
AND SEALANT BY
OTHERS
Mullion covers are not intended to create a completely waterproof seal.
See typical sealant details.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-10
MULLION APPLICATIONS
Scale 6" = 1' 0"
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
INTERIOR WOOD
MULLION COVER #2941
CORRUGATED
FASTENERS
@ 12" (305) O. C. BY
OTHERS
USED TO JOIN TWO CLAD
UNITS WHERE NO MULLION
REINFORCEMENT IS REQUIRED
MULLION
REINFORCEMENT
#2941
1" x 1/2" CROWN
STAPLE B.O.
CONTINUOUS
SEALANT BY
OTHERS
TYPICALLY USED WITH 1/2" (10)
MULLION REINFORCEMENT #0A6G
NOTE: Apply continuous bead of sealant to inside corners of mullion
cover before installing to units.
SHIM AND
LEVEL UNITS AS
REQUIRED
CONTINUOUS
WOOD
BLOCKING,
WOOD TRIM,
BACKER ROD
AND SEALANT BY
OTHERS
STANDARD SIZE MULLION COVERS
AVAILABLE IN 1/2" INCREMENTS
FROM 1" to 4" AS NEEDED.
2" (51) MULLION
COVER #72A9
NOTE: Apply continuous bead of sealant to inside corners of mullion
cover before installing to units.
INSTALLATION
CLIPS #5071
@ 18" (457)
O.C. (REFER TO
PAGE 17 FOR
ADDITIONAL
SPACING
INFORMATION)
Mullion covers are not intended to create a completely waterproof seal.
See typical sealant details.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-11
MULLION REINFORCEMENTS
Scale 3" = 1' 0"
INSTALLATION
ACCESSORIES
M U LLIO N R E IN F O R C E M E N T S
Accessory
Indiv.
Part No.
Box
No.
0A6G
0A6K
512C
000F
512A
72WQ
512B
512D
500P
0EUA
0EUL
00NN0003
0CSL0025
00NN0001
0CUH
00NN0002
00NN0004
0DKM0000
Mullion Reinforcement 1/2" x 3-9/16"
Mullion Reinforcement 1/2" x 4-9/16"
Clip Mullion Anchor
High Performance Mullion Anchor
Wood Mullion Anchor
Mullion End Splice - 96"
Subsill Mullion Anchor
Fin Mullion Anchor
20" Plate
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-12
REINFORCING MULLION APPLICATIONS
Scale 6" = 1' 0"
WOOD TRIM
BY OTHERS
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
1" x 1/2" Crown
Staple B.O.
CONTINUOUS
SEALANT BY OTHER
NOTE: Apply continuous bead of sealant to inside corners
of mullion cover before installing to units.
1. Attach 1/2" mullion reinforcements with clips #512C, 000F,
512B or 512D.
2. Can be used either horizontally or vertically for wind
load mullion reinforcement. Note: Recommended use is
vertically with subsill for large combination assemblies.
3. Do not use as part of building structure.
4. Refer to Combinations Section for wind load information,
(max. Length 144").
NOTE: Apply continuous bead of sealant to inside corners of
mullion cover before installing to units.
WOOD TRIM
BY OTHER
1" x 1/2" CROWN
STAPLE B.O.
CONTINUOUS
SEALANT BY OTHER
Example Assembly
Refer to the Combination Recomendations section and Combination size tables to determine required reinforcement method.
FACTORY ASSEMB L E D WO O D MU L L I O N E ND AN C H O R S
Rough Framing: Wood, Concrete,
CMU, etc.
Wood Mullion Anchor
Wood Reinforcing mullion
1" to 4" on 1/2" increments.
E nd A nc h o rs A tt ac h m e n t:
• For Wood Framing: Use 5 #10 x 3" Wood Screws.
• For Concrete/CMU: Use
5-3/16" Masonry Screw.
Screws have a 1" embedment into wood buck or concrete below subsill.
1 /2 " F IN M U LLI O N E N D AN C H O R S
Rough Framing: Wood,
Concrete, CMU, etc.
Fin Anchor #512D
1/2" x 3-9/16"
Reinforcing mullion
#0A6G
Fin Anchor #512D
E n d An chors
Atta c hm e n t:
• For Wood:
Use 5 - #10 x 3"
Wood Screws.
• For Concrete/
CMU: Use 3/16"
Masonry Screw.
The 1/2" mullion assembly with end anchors 512D (fin mullion anchor), 000F (high performance fin mullion anchor) or 512A (wood fin mullion anchor) allow for installation of
combinations that are assembled prior to being placed in the opening. Combinations assembled with this method should not exceed 144 square feet in total size. Always handle
combinations in vertical orientation.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-13
EXPANSION MULLION COVER APPLICATIONS
T-Expansion Mullion Application
Expansion Mullion Cover
Scale 6" = 1' 0"
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-14
EXPANSION MULLION COVER APPLICATIONS
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
Clip Installation
Fin Installation
FRAME
FRAME
VARIES
3/8"
[10]
FRAME
3/8"
[10]
3/8"
[10]
EXPANSION MULLION COVER
72HF
VARIES
FRAME
3/8"
[10]
SHIM AND LEVEL UNITS AS REQUIRED
CONTINUOUS WOOD BLOCKING, WOOD
TRIM, BACKER ROD AND SEALANT BY
OTHERS
1"
[25]
Clip Installation
Varies
FRAME
FRAME
3/8"
[10]
INSTALLATION CLIPS #5071 @ 18" (457) O. C.
2"
[51]
Fin Installation
FRAME
VARIES
3/8"
[10]
1/2"
[13]
EXPANSION MULLION COVER WITH
VINYL BULB GASKET
1AAF
FRAME
1/2"
[13]
INSTALLATION CLIPS #5071 @ 18" (457) O. C.
3/8"
[9]
CONTINUOUS WOOD BLOCKING, WOOD
TRIM, BACKER ROD AND SEALANT BY OTHERS
1 1/4"
[32]
1 5/8"
[42]
NOTE: APPLY CONTINUOUS BEAD OF SEALANT TO INSIDE
CORNERS OF MULLION COVER BEFORE INSTALLING UNITS.
Rev. 02/24/2016
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-15
INSTALL ATION SYSTEMS
New Construc tion — Punched Opening
Mulling Considerations
INSTALLATION
ACCESSORIES
M U LLI O N R E I N F O R C E M E NT
1 /2 " X 3 - 9 /1 6 "
Burlington Apartments, Portland, OR
Ankrom Moisan Associated Architects
These recommendations
apply to a typical
grouping of any
combination of window
units that form a fourway mullion intersection.
STAN DAR D M U LLI O N COVER
Refer to single-unit opening recommendations in addition to the following:
1 1/2" clearance is recommended at each jamb in masonry construction
and/or when window opening height or width is 10'
or greater.
2 All four-way mullion intersections require reinforcing mullion in one
direction (either vertically or horizontally). See mullion load chart pages
in the Installation section on PellaADM.com.
3 Check combination (joining) mullion limitation for specified wind
loading. Combination (joining) and reinforcing mullions are shown on
the mullion load chart pages in the Installation section on PellaADM.
com.
4 Subsill systems that weep incidental moisture to the exterior are
recommended for water management in openings where the potential
for water infiltration is increased and may not be adequately managed
by the building weather barrier, flashings and drainage system. Sample
conditions include, but are not limited to: increased level of exposure
due to multi-story construction, high weather exposure, recaulking
would be difficult or unlikely, non-standard installation methods, or
when there are multiple units joined within the opening.
M U LLI O N COV E R
( R AN GE : F R AM E TO F R AM E 1 " TO 4")
E X PAN S I O N M U LLIO N COVER
If lower unit is venting, horizontal reinforcing mullion may be required to carry
weight of upper units. See Weight Limitations Over Windows information in the
Installation and Performance section on PellaADM.com.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-16
INSTALL ATION SYSTEMS
New Construc tion — Punched Opening
L-Receptor and 2" Ver tical Struc tural Receptor
INSTALLATION
ACCESSORIES
L-Receptor
72AK
L-Receptor Clip 5027
Bulb Gasket
0SA9
HEAD
CLAD / WOOD SUBSILL 4049
& CLIP 7366
SILL
2" Structural Receptor Mullion 0APK
JAMB
VERTICAL MULLION
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-17
INSTALL ATION SYSTEMS
New Construc tion — Store Fronts
1 3/4"
[44]
INSTALLATION
ACCESSORIES
2"
[51]
Horizontal Receptor Mullion
1 3/4" Structure 50E3
Vertical Receptor Mullion
2" Structure 50E5
Burlington Apartments, Portland, OR
Ankrom Moisan Associated Architects
2"
[51]
1
1 1/2" Mullion Cover 736B
2
4
Vertical Mullion
Window Wall Channel 2" Structure 50E4
Horizontal Mullion
Expansion Cover with Gasket 1AAF
5
Standard Frame Expander
Elevation
6
3
Refer to single-unit opening recommendations in addition to the following:
• 1/2" clearance is recommended at each jamb in masonry construction and/or when window opening height or width is 10' or greater.
• All four-way mullion intersections require reinforcing mullion in one direction (either vertically or horizontally). See mullion load chart
pages in the Installation section on PellaADM.com.
• Check combination (joining) mullion limitation for specified wind loading. Combination (joining) and reinforcing mullions are shown
on the mullion load chart pages in the Installation section on PellaADM.com.
• Subsill systems that weep incidental moisture to the exterior are recommended for water management in openings where the potential
for water infiltration is increased and may not be adequately managed by the building weather barrier, flashings and drainage system.
Sample conditions include, but are not limited to: increased level of exposure due to multi-story construction, high weather exposure,
recaulking would be difficult or unlikely, non-standard installation methods, or when there are multiple units joined within the opening.
If lower unit is venting, horizontal reinforcing mullion may be required to carry weight of upper units. See Weight Limitations Over Windows
information in the Installation and Performance section on PellaADM.com.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-18
INSTALL ATION SYSTEMS
New Construc tion — Store Fronts
INSTALLATION
ACCESSORIES
4
1
HEAD
JAMB
5
2
HORIZONTAL MULLION
VERTICAL MULLION
6
3
SILL
SILL
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-19
INSTALL ATION SYSTEMS
New Construc tion — Window Walls
INSTALLATION
ACCESSORIES
1
1 3/4"
[44]
2
5
4
6
Horizontal Receptor Mullion
1 3/4" Structure 50E3
2"
[51]
3
E L E VAT I O N
Vertical Receptor Mullion
2" Structure 50E5
Environmental Nature Center, Newport Beach, CA; LPA Inc. LEED® Platinum
Photo © Costea Photography, Inc.
• 1/2" clearance is recommended at each jamb in masonry construction
and/or when window opening height or width is 10'
or greater.
• All four-way mullion intersections require reinforcing mullion in one
direction (either vertically or horizontally). See mullion load chart pages in
the Installation section on PellaADM.com.
• Check combination (joining) mullion limitation for specified wind loading.
Combination (joining) and reinforcing mullions are shown on the mullion
load chart pages in the Installation section on
PellaADM.com.
• Subsill systems that weep incidental moisture to the exterior are
recommended for water management in openings where the potential
for water infiltration is increased and may not be adequately managed
by the building weather barrier, flashings and drainage system. Sample
conditions include, but are not limited to: increased level of exposure due
to multi-story construction, high weather exposure, recaulking would be
difficult or unlikely, non-standard installation methods, or when there are
multiple units joined within the opening.
2"
[51]
Refer to single-unit opening recommendations in addition
to the following:
Vertical Mullion
Window Wall Channel 2" Structure 50E4
1 1/2" Mullion Cover 736B
Horizontal Mullion
Expansion Cover with Gasket 1AAF
Standard Frame Expander
If lower unit is venting, horizontal reinforcing mullion may be required to carry
weight of upper units. See Weight Limitations Over Windows information in the
Installation and Performance section on PellaADM.com.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-20
INSTALL ATION SYSTEMS
New Construc tion — Window Walls
INSTALLATION
ACCESSORIES
4
1
HEAD
2
JAMB
5
HORIZONTAL MULLION
3
VERTICAL MULLION - STEEL OPTION
6
SILL
Scale 3" = 1' 0"
VERTICAL MULLION
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-21
EXTERIOR TRIM - FIELD APPLIED APPLICATION
Traditional Trim and Clad Sill Nose
Siding Applications
Scale 6" = 1' 0"
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
SHIM AND LEVEL UNITS AS REQUIRED
CONTINUOUS WOOD BLOCKING,
WOOD TRIM, BACKER ROD AND
SEALANT BY OTHERS
Aluminum traditional flat trim is to be used in frame construction with standard installation fins only.
Maximum length is 8'.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-22
EXTERIOR TRIM - FIELD APPLIED APPLICATION
Traditional Trim and Clad Sill Nose
Brick Veneer Applications
INSTALLATION
ACCESSORIES
SHIM AND LEVEL UNITS AS REQUIRED
CONTINUOUS WOOD BLOCKING,
WOOD TRIM, BACKER ROD AND
SEALANT BY OTHERS
FIE L D APP L IED EXTE RI O R TRI M
Accessory
Traditional Trim
3-1/2" Flat Trim Head
3-1/2" Flat Trim Jamb
1/2" Clad Sill Nose
Indiv.
Part No.
Box
No.
72D6
72D4
72D5
72E0
72D8
0DC3
0DC4
0DC5
0DC6
Aluminum traditional flat trim is to be used in frame construction with standard installation fins only.
Maximum length is 8'.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-23
EXTERIOR TRIM - FIELD APPLIED APPLICATION
Flat Trim with Clad Sill Nose
Siding Applications
Scale 6" = 1' 0"
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
Aluminum traditional flat trim is to be used in frame construction with standard installation fins only.
Maximum length is 8'.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-24
EXTERIOR TRIM - FRAME EXPANDER
Frame Expander
Frame Expander Receptor
Scale 6" = 1' 0"
Scale 3" = 1' 0"
PELLA Window and Door Installation Sealant. and
Water Resistant Backer Rod and Sealant. by Others
1 1/16"
[27]
5/16"
[8]
1 1/4"
[32]
1/2"
[13]
INSTALLATION
ACCESSORIES
Low Expansion, Low Pressure Polyurethane
Insulating Window and Door Sealant.
(do not use high pressure or latex foam.)
INSTALLATION CLIPS
@ 18" (457) O.C.
Continuous Wood Blocking, Wood Trim
Continuous Bead of Sealant by Others.
1" FRAME EXPANDER
FRAME EXPANDER RECEPTOR
FRAME EXPANDER RECEPTOR
Used to receive and trim outside edge of frame
expander as an alternate to face-screwing edge
into blocking. Return leg can be field-trimmed as
required.
FRAME
ROUGH OPENING
MASONRY OPENING
For use with aluminum-clad wood windows
Provides the look of flat trim
Receptor available for wide trims
Paint finish that matches windows
Available with or without brickmould
Custom brickmould profiles available
Straight or curved
Trim to frame opening
Factory Supplied Frame Expander Kits available,
trim is processed and notched to length per unit
configuration, saves time and scrap on the job site.
4 1/4"
[108]
HEAD
1 3/16"
[30]
1 15/16"
[49]
2 11/16"
[68]
Used at head, jamb and/or sill.
1" Frame Expander
4" Frame Expander
MASONRY OPENING
2 1/2" Frame Expander
FRAME
3/4"
[19]
3/8"
[10]
1 3/4" Frame Expander
ROUGH OPENING
6"
[152]
•
•
•
•
•
•
•
•
•
3/8"
[10]
Application: New Construction or Renovation
JAMB
6" Frame Expander
Continuous Wood Blocking, Wood Trim
Continuous Bead of Sealant by Others.
INSTALLATION CLIPS
@ 18" (457) O.C.
PELLA Window and Door Installation Sealant. and
Water Resistant Backer Rod and Sealant. by Others
1" FRAME EXPANDER
FRAME EXPANDER RECEPTOR
Low Expansion, Low Pressure Polyurethane
Insulating Window and Door Sealant.
(do not use high pressure or latex foam.)
Shim Units Plumb and Level as Required
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-25
EXTERIOR TRIM - NEW CONSTRUCTION APPLICATION
Aluminum Brickmould
Aluminum Brickmould Clip
INSTALLATION
ACCESSORIES
1 3/16"
[30]
1 15/16"
[49]
2 1/2"
47D6
1 3/4"
47D5
1"
47D4
ROUGH OPENING
3/8"
[10]
FRAME
4"
47E3
MASONRY OPENING
6"
47D3
2 11/16"
[68]
4 1/4"
[108]
6"
[152]
3 3/4"
[95]
3/8"
[10]
Frame Expander
HEAD
1 7/8"
7SBP - 0SBN
FRAME
1 1/2"
[37]
1 11/16"
[43]
1 3/16"
[30]
3/8"
[10]
2 1/4"
[57]
15/16"
[23]
ROUGH OPENING
1 7/8"
72AP - 72AQ
MASONRY OPENING
1 1/2"
[37]
JAMB
1 7/8"
[48]
1 7/8"
[48]
1 1/16"
[27]
1 7/16"
[36]
ROUGH OPENING
3/8"
[10]
FRAME
2 1/16"
72AN - 72AQ
5/8"
[16]
1 5/16"
[33]
MASONRY OPENING
2 1/16"
[52]
7/8"
[22]
1 1/2"
[38]
1 1/2"
7SB7 - 0SB8
1 5/16"
7SB1 - 0SBQ
1 1/16"
[27]
1 5/8"
[41]
1 1/2"
[38]
3 3/4"
[95]
3/8"
[10]
Custom Brickmould with Clip
1 11/16"
7SBX - 0SBN
SILL
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-26
EXTERIOR TRIM - RENOVATION APPLICATION
INSTALLATION
ACCESSORIES
Aluminum Brickmould
Aluminum Brickmould Clip
Existing Wall
Construction
1 3/4"
47D5
1"
47D4
3/8"
[10]
FRAME
1 3/16"
[30]
1 15/16"
[49]
2 1/2"
47D6
ROUGH OPENING
4"
47E3
MASONRY OPENING
6"
47D3
2 11/16"
[68]
4 1/4"
[108]
6"
[152]
1 1/2"
[38]
3/8"
[10]
Frame Expander
HEAD
Existing Wall
Construction
2 1/4"
[57]
FRAME
Shim, Level & Plumb
Units as Required
1 1/2"
[37]
1 11/16"
[43]
1 3/16"
[30]
1 1/2"
ROUGH OPENING
[14] 3/8"
[10]
FRAME
MASONRY OPENING
1 7/8"
7SBP - 0SBN
15/16"
[23]
Wood Blocking, Trim and
Sealant by Others.
JAMB
1 1/2"
[37]
1 7/8"
[48]
1 7/8"
[48]
1 7/8"
72AP - 72AQ
1 5/16"
[33]
3/8"
[10]
1 7/16"
[36]
1 1/16"
[27]
5/8"
[16]
ROUGH OPENING
2 1/16"
72AN - 72AQ
MASONRY OPENING
2 1/16"
[52]
7/8"
[22]
1 1/2"
[38]
1 1/2"
7SB7 - 0SB8
1 5/16"
7SB1 - 0SBQ
1 1/16"
[27]
1 5/8"
[41]
1 1/2"
[38]
1 1/2"
[38]
3/8"
[10]
Custom Brickmould with Clip
Existing Wall
Construction
1 11/16"
7SBX - 0SBN
SILL
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-27
ENDURACL AD® EXTERIOR TRIM - FACTORY APPLIED
INSTALLATION
ACCESSORIES
Trim Profiles
Factory Installed Guidelines
• Maximum size is 138" x 101"
1/2" Sill
Nose
• Trim comes assembled and installed on unit and includes endcaps and
fins as neccessary.
1" Sill Nose 2" Sill Nose
3-1/2"
Flat Casing
S I LL N O S E CO M PAT I B ILITY
• Factory Applied Trim is available on all Aluminum Clad products,
including curved and angled shapes, with the following exceptions:
ƒƒ Architect Series® and Designer Series® four-panel patio doors
ƒƒ ProLine® hinged and sliding doors
ƒƒ Precision Fit® pocket replacement windows
ƒƒ Bay / Bow windows
1-1/2" Brickmould
●
●
●
3-1/2" Brickmould
●
●
●
3-1/2"Flat Casing
●
●
●
Jefferson
●
●
Monroe
●
●
●
ƒƒ Architect Series® Specialty windows
HEAD DRIP CAP
Monroe
50NN
1 9/16"
[40]
1 7/16"
[36]
11/16"
[18]
11/16"
[18]
3/8"
[10]
11/16"
[18]
Standard
50GU
5/16"
[8]
11/16"
[18]
1/4"
[6]
2 5/16"
[58]
2"
[50]
Jefferson
50NL
3/8"
[10]
1 11/16"
[43]
2 1/4"
[57]
3 1/2" Flat Casing
50NM
1 3/8"
[34]
Brickmould
70F5
Monroe
50GF
1/2" Nose
50GZ
2"
[51]
1" Nose
w/ Nose Extension
50H0, 50H8
NEW CONSTRUCTION FIN
Standard Clad
Trim Fin
70F2
2 5/8"
[67]
1 3/16"
[30]
1 3/16"
[30]
Standard Clad
Trim Fin
50HB
3 1/2" Flat Casing
50GJ
13/16"
[21]
1 3/16"
[30]
1" 1 3/16"
[25] [30]
1"
[25]
5/16"
[8]
Jefferson
50GC
3 1/2" Brickmould
50G9
SILL NOSE
1/2"
[13]
3 1/2"
[89]
3 1/2"
[89]
2 3/16"
[55]
1 1/2"
[37]
1 1/2"
[37]
1 9/16"
[40]
3 1/2"
[89]
TRIM PROFILES
2" Nose
w/ Nose Extension
50H1, 50H8
3 1/2" Flat Casing
50MD
RENOVATION REPLACEMENT FIN
Standard Clad
Trim Sill Fin
70F4
Standard Clad Trim
Replacement Fin
50HE
Clad Trim
Replacement Fin
50H9
Standard Clad Trim
Replacement Sill Fin
50HJ
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-28
ENDURACL AD® EXTERIOR TRIM - FACTORY APPLIED
INSTALLATION
ACCESSORIES
Ordering Information
Head to Jamb joints are
mitered except for 3-1/2"
Flat Casing, which uses
butt joints and head end
caps.
All applied trim includes end caps as needed and
installation fin as determined by your selections (new
construction or replacement/renovation).
3-1/2" Trim fins are used for flashing purposes only, and
are not intended for anchoring/attachement of the unit.
Performing whole unit field application of EnduraClad
Exterior Trim in the field may result in voiding product
warranties.
MO.
FR.
A
C
FR.
MO.
B
A
A&B
Jamb pieces are
mitered to the slope
of the sill. The sill is
notched where the
jambs meet the sill.
Sill nose extensions
are included where
needed. Sill end caps
are included..
B
Head
3-1/2" Flat
Casing Sill
+ 1.18"
+ 3.21"
+ 3.21"
+ 3.21"
+ 1.18"
—
—
+ 3.21"
—
—
FRAME TO EXTE RI O R TRI M
1-1/2" Brickmould
+ 1.18"
3-1/2" Brickmould
+ 3.21"
3-1/2" Flat Casing
+ 3.21"
Jefferson
+ 3.21"
Monroe
+ 1.18"
C
1/2" Sill Nose 1" Sill Nose
+ 1.18"
+ 1.18"
+ 1.18"
—
—
+ 1.892"
+ 1.892"
+ 1.892"
+ 1.892"
+ 1.892"
2" Sill Nose
+ 2.892"
+ 2.892"
+ 2.892"
+ 2.892"
+ 2.892"
C
A
Jamb (single)
These dimensions do NOT include 3/8" per side for sealant, foam and backer rod, only the dimension of the trim
beyond the unit frame.
All example images on this page use 1-1/2" Brickmould with 1/2" Sill nose
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-29
ENDURACL AD® EXTERIOR TRIM - FACTORY APPLIED APPLICATION
INSTALLATION
Brickmould with 1/2" Sill Nose
ACCESSORIES
Siding Applications
Scale 6" = 1' 0"
Scale 3" = 1' 0"
FRAME
HEAD
BRICKMOULD
ROUGH OPENING
SHIM AND LEVEL UNITS AS
REQUIRED
CONTINUOUS WOOD
BLOCKING, WOOD
TRIM, BACKER ROD AND
SEALANT BY OTHERS
FRAME
15/16"
[23]
3/8"
[10]
1/8"
[3]
5/16"
[8]
1 1/2"
[37]
1 3/16"
[30]
ROUGH OPENING
1 5/16"
[34]
15/16"
[24]
3/8"
[10]
1/8"
[3]
1 5/8"
[42]
FRAME
15/16"
[23]
3/8"
[10]
9/16"
[15]
1/16"
[2]
1 3/16"
[29]
15/16"
[25]
1/8"
[3]
15/16"
[25]
1/2"
[13]
5/16"
[8]
1/2" SILL NOSE
ROUGH OPENING
JAMB
7/8"
[23]
13/16"
[21]
SILL
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-30
ENDURACL AD® EXTERIOR TRIM - FACTORY APPLIED APPLICATION
INSTALLATION
Brickmould with 1/2" Sill Nose
ACCESSORIES
Brick Veneer Applications
Scale 6" = 1' 0"
Scale 3" = 1' 0"
FRAME
3/8"
[10]
1 3/16"
[30]
ROUGH OPENING
Standard
MASONRY OPENING
1/4"
[6]
11/16"
[18]
3/8"
[10]
1 11/16"
[43]
HEAD
3/8"
[10]
1 3/16"
[30]
Protect units and trim from
excess mortar when placing
brick around opening.
FRAME
BRICKMOULD
ROUGH OPENING
MASONRY OPENING
1 3/16"
[30]
5/16"
[8]
1 1/2"
[37]
3/8"
[10]
1 5/16"
[34]
1 5/8"
[42]
FRAME
ROUGH OPENING
3/8"
[10]
3/8"
[10]
1 3/16"
[29]
MASONRY OPENING
9/16"
[15]
1/16"
[2]
1 3/16"
[29]
15/16"
[25]
15/16"
[25]
1/2"
[13]
5/16"
[8]
JAMB
7/8"
[23]
13/16"
[21]
1/2" SILL NOSE
SHIM AND LEVEL UNITS AS REQUIRED
CONTINUOUS WOOD BLOCKING, WOOD TRIM,
BACKER ROD AND SEALANT BY OTHERS
SILL
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-31
ENDURACL AD® EXTERIOR TRIM - FACTORY APPLIED APPLICATION
INSTALLATION
Brickmould with 1/2" Sill Nose
ACCESSORIES
Replacement Brick Veneer Applications
Scale 6" = 1' 0"
3/8"
[10]
FRAME
MASONRY OPENING
1 3/16"
[30]
HEAD
BRICKMOULD
3/8"
[10]
FRAME
ROUGH OPENING
MASONRY OPENING
1 3/16"
[30]
3/8"
[10]
5/16"
[8]
1 1/2"
[37]
1 5/8"
[42]
ROUGH OPENING
1 3/16"
[30]
3/8"
[10]
Scale 3" = 1' 0"
13/16"
[21]
FRAME
ROUGH OPENING
3/8"
[10]
3/8"
[10]
7/8"
[23]
1 3/16"
[29]
9/16"
[15]
1/16"
[2]
1 3/16"
[29]
15/16"
[25]
1/2"
[13]
5/16"
[8]
1/2" SILL NOSE
MASONRY OPENING
JAMB
SHIM AND LEVEL UNITS AS REQUIRED
CONTINUOUS WOOD BLOCKING, WOOD TRIM,
BACKER ROD AND SEALANT BY OTHERS
SILL
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-32
ATTACHMENT OPTIONS
INSTALLATION
ACCESSORIES
Receptor and Subframe Systems
T-Subframe Application
2 7/8"
[73] MAX.
5/8"
[16]
3/8"
[10]
HEAD
FRAME
SUBFRAME
3 1/2"
[89]
T-SUBFRAME HEAD
#72F6
MASONRY OPENING
CLIP #7363
EXISTING OPENING
3 1/2"
[89]
Existing Wall Construction and
Steel Frame.
CLIP #7363
6 1/2"
[165]
Existing Wall Construction
and Steel Frame.
FRAME
FRAME
JAMB
SILL
*NOTE: Subframe leg may be
field-cut as required.
T-SUBFRAME SILL
#73H8
2 1/4"
[58] MAX.
3"
[76]
3/4"
[19]
SUBFRAME
SUBFRAME
2 7/8"
[73] MAX.
5/8"
[16]
3/8"
[10]
EXISTING OPENING
EXISTING OPENING
PACKAGE #0DB00000:
WINDOW CLIP #5027 AND
#8x5/8" PAN HEAD PHILLIPS SCREW
MASONRY OPENING
SUBFRAME CLIP
#7363
MASONRY OPENING
T-SUBFRAME JAMB
#73H9
Existing Wall Construction and
Steel Frame.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-33
ATTACHMENT OPTIONS
INSTALLATION
ACCESSORIES
Receptor and Subframe Systems
Standard Subframe Application
Continuous Perimeter Sealant (See
installation instructions)
*NOTE: Subframe leg may
be field-cut as required.
8"
[204]
HEAD
FRAME
SUBFRAME
EXISTING OPENING
SUBFRAME CLIP #7363
MASONRY OPENING
3 1/2"
[89]
2 7/8"
[73] MAX.
5/8"
[16]
3/8"
[10]
EXISTING WALL CONSTRUCTION
AND WOOD WINDOW FRAME
SUBFRAME HEAD #7355
FRAME
FRAME
SUBFRAME
SUBFRAME
EXISTING OPENING
EXISTING OPENING
JAMB
SILL
3 9/16"
[91] MAX.
3 9/16"
[90]
PACKAGE #0B050000: WINDOW
CLIP #5087 AND #8x5/8" PAN HEAD
PHILLIPS SCREW
MASONRY OPENING
SUBFRAME JAMB #7357
MASONRY OPENING
3 1/2"
[89]
2 7/8"
[73] MAX.
5/8"
[16]
3/8"
[10]
EXISTING WALL CONSTRUCTION
AND WOOD WINDOW FRAME
SUBFRAME SILL #7360
EXISTING WALL CONSTRUCTION
AND WOOD WINDOW FRAME
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-34
ATTACHMENT OPTIONS
Receptor and Subframe Systems
Expander and Trim Application
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-35
BREAK METAL
INSTALLATION
ACCESSORIES
Covers and Trim
The Pella accessory system includes all of the most-often-specified standard items shown in this Architectural Design Manual as well as
other specials shown here.
In addition, completely custom / special installation, panning, and trim systems can be designed and fabricated by Pella for specific
project requirements. Shapes shown on the next two pages can be ordered to various dimensions needed. Consult your local Pella
sales representative.
MUL L ION COVERS
MUL L ION TRIM
S ILL T R IM
H EAD JAMB TRIM
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-36
BREAK METAL
Sill Flashing
INSTALLATION
ACCESSORIES
S ILL FL ASHIN G
AT TACHMEN T CL IP
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-37
BREAK METAL
Sill Flashing Application
INSTALLATION
ACCESSORIES
Custom A luminum Sill F las h ing
•Custom 0.050" (1.27) aluminum sill flashings can
be fabricated to specifications as required. Detail
shows typical conditions where custom aluminum sill
flashing might be used.
•The use of this sill flashing is recommended only in
climates where thermal conductance is not likely to
occur.
•Where aluminum comes into contact with cement
materials or steel, apply protective coating to
separate galvanically incompatible materials.
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-38
WOOD EXTERIOR
INSTALLATION
ACCESSORIES
Exterior Mullion Covers
I N T E R I O R M U LLI O N COV E R S
Accessory
Casement Interior
Double-Hung Interior
Bay Interior
Indiv.
Part No.
Box
No.
26A9
2600
3015
09GK
0BMU
0B42
Indiv.
Part No.
Box
No.
2903
2942
29T0
3046
3149
0B97
0921
—
06M2
0B44
E X T E R I O R M U LLI O N COV E R S
Accessory
Casement Exterior–Horizontal
Casement Exterior–Vertical
Double-Hung Exterior–Horizontal
Double-Hung Exterior–Vertical
Bow Casement Exterior
See the Bay/Bow Section in the Architectural Design Manual for
application details.
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-39
WOOD EXTERIOR
Brickmould and Subsill
INSTALLATION
ACCESSORIES
SUBSIL L S AND E XTE RI O R TRI M
Accessory
3-1/2" with Rabbet
3-1/2 " without Rabbet
3-1/2" Flat Casing with Rabbet
1-7/8" Curved with Rabbet
1-7/8" Curved without Rabbet
1-7/8" with Rabbet
1-7/8" without Rabbet
Accessory
1-1/8" Subsill
1-7/8" Subsill
Double-Hung Sill Nose
Sill Flashing
Indiv.
Part No.
Box
No.
38L6
38L5
380R
33M4
33P2
3443
3419
0F08
0F07
0DAZ
—
—
0B96
0BB0
Indiv.
Part No.
Box
No.
3544
250H
3315
—
0920
093H
0C29
0D98
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-40
INTERIOR TRIM
INSTALLATION
ACCESSORIES
2 1/2"
[64]
2 1/2"
[64]
2 1/2" 1
30AY, 30BD
2 1/2" 2
31U7
2 1/2" 3
31UF
3" 1
31UA
5/8"
[16]
5/8"
[16]
3 1/2"
[89]
5/8"
[16]
3 1/4"
[83]
5/8"
[16]
5/8"
[16]
7/16"
[11]
3"
[76]
5/8"
[16]
2 1/2"
[64]
RANCH
3 1/2"
[89]
Casing
3 1/4" 1
31U9
3 1/2" 1
30U7, 30UA
3 1/2" 2
31U8
5/8"
[16]
3 1/4"
[83]
3 1/4"
[83]
3 1/4" 1
31UB
3 1/4" 2
31UC
5/8"
[16]
5/8"
[16]
3 1/2"
[89]
5/8"
[16]
3 1/2"
[89]
5/8"
[16]
3 1/4"
[83]
CRAFTSMAN
3 1/4" 3
31UD
3 1/2" 1
30BA
3 1/2" 2
31UE
5/8"
[16]
5/8"
[16]
5/8"
[16]
5/8"
[16]
5/8"
[16]
5/8"
[16]
2 1/2"
[64]
2 1/2"
[64]
2 1/2"
[64]
2 1/2"
[64]
2 1/2"
[64]
2 1/2"
[64]
COLONIAL
2 1/2" 1
30AX, 30BB
5/8"
[16]
2 1/2" 3
30NY
5/8"
[16]
2 1/2" 5
31TZ
3/4"
[19]
3/4"
[19]
5/8"
[16]
3 1/2" 1
30AZ, 312R
3 1/2" 2
30NW, 312S
3 1/2" 3
31U4
2 1/2"
[64]
2 1/2"
[64]
2 1/2" 1
31UJ
3/4"
[19]
3/4"
[19]
2 1/2" 2
31UK
2 3/4" 1
31UL
3 1/2" 4
31U5
5/8"
[16]
3 1/2" 5
31U6
3/4"
[19]
5/8"
[16]
3"
[76]
5/8"
[16]
2 3/4"
[70]
5/8"
[16]
2 3/4"
[70]
5/8"
[16]
2 1/4"
[57]
PROVINCIAL
2 3/4" 2
31U1
2 1/2" 6
31U0
3 1/2"
[89]
3 1/4"
[83]
3 1/4" 1
31U2
2 1/4" 1
31UP
2 1/2" 4
31TY
3 1/2"
[89]
5/8"
[16]
2 1/2" 2
30NX, 312Q
3" 1
31UG
3" 2
31UH
5/8"
[16]
4 1/4"
[108]
2 1/4" 1
31U3
3 1/2"
[89]
2 1/4"
[57]
5/8"
[16]
3 1/2" 1
31UM
4 1/4" 1
31UN
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-41
INTERIOR TRIM
INSTALLATION
ACCESSORIES
Trim Accessories
Cove Trim 1
60U6 / 60U9
Lattice 1
31VP
Lattice 2
31VV
5 1/8"
[129]
3 5/8"
[91]
Lattice 3
260A
Lattice 4
260P
Lattice 5
261C
1/2"
[13]
1/2"
[13]
STOOL
1/4"
[6]
1 3/8"
[36]
2 1/2"
[64]
Quarter Round 2
31VQ
Quarter Round 1
30U5 / 30U8
1/2"
[12]
3/4"
[19]
3/4"
[19]
3/4"
[19]
3/4"
[19]
3/4"
[19]
1/2"
[13]
1/4"
[6]
COVE MOULD
5 1/4"
[133]
BASE TRIM
1/4"
[6]
5/8"
[16]
LATTICE
1 5/8"
[41]
Round 1
32WH
5/8"
[16]
1 5/8"
[41]
Ogee 1
32WJ
1/2"
[13]
5/8"
[16]
1/8"
[3]
2 7/16"
[62]
Ogee 1
31VR
1/2"
[13]
2 7/16"
[62]
Round 1
3146
1/8"
[3]
5/8"
[16]
5/8"
[16]
4 9/16"
Jamb
6 9/16"
Jamb
Ogee 2
31VS
Round 2
30LC
Colonial 3
31VF
Colonial 2
31VL
Colonial 4
30VG
1 5/8"
[41]
Ranch 1
31VK
1 5/8"
[41]
5/8"
[16]
1 3/8"
[35]
1 1/4"
[32]
1 13/16"
[47]
5/8"
[16]
1 3/4"
[44]
5/8"
[16]
3/8"
[10]
3/8"
[10]
5/8"
[16]
Colonial 1
30VM
7/8"
[22]
1 5/8"
[41]
Ogee 2
31VW
STOP
7/8"
[22]
2 5/8"
[67]
1/8"
[3]
1 5/8"
[41]
Round 1
30VJ
Round 2
31VH
3/4"
[19]
1/2"
[12]
Round 2
3204
2 5/8"
[67]
1/8"
[3]
4 7/16"
[113]
5/8"
[16]
5/8"
[16]
4 7/16"
[113]
Square 1
31VN
SPREAD MULLION COVER
5/16"
[9]
1/2" Mullion 1
260A
1" Mullion 1
260B
1 1/2" Mullion 1
260D
2" Mullion 1
260N
2 1/2" Mullion 1
260P
3" Mullion 1
260V
3 1/2" Mullion 1
261B
1/4"
[6]
5 1/8"
[129]
1/4"
[6]
4 5/8"
[117]
1/4"
[6]
4 1/8"
[104]
1/4"
[6]
1/4"
[6]
3 5/8"
[91]
1/4"
[6]
1/4"
[6]
2 5/8"
[66]
1 3/8"
[36]
1/4"
[6]
DOUBLE-HUNG
#2600
2 1/8"
[53]
CASEMENT
#26A9
3 1/8"
[79]
1 5/32"
[29]
1 25/32"
[45]
1/4"
[6]
4" Mullion 1
261C
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-42
INTERIOR TRIM
INSTALLATION
ACCESSORIES
ReadyTrim
READY TRIM
RE A DY TRI M P LU S
Pine
For use with or without Jamb
Extensions
Save time when Jamb Extensions
are needed
4 pieces of trim, PreAssembled
4 pieces of trim, 4 Jamb
Extensions,
4 Cover Strips, Pre-Assembled
Packaged by unit, max 3 per
carton
R E ADY T R IM P R O F ILE O PT IO N S
Packaged by unit, max 1 per
carton
30AY
2-1/2” Ranch 1
31U7
2-1/2” Ranch 2
2-1/2” Ranch 3
3” Ranch 1
31U9
3-1/4” Ranch 1
RE A DY TRI M P LU S
K NO CK D O W N
30U7
3-1/2” Ranch 1
31U8
3-1/2” Ranch 2
Pre-measured and kitted to
save time
Pre-measured and kitted to save
time
31UB
3-1/4” Craftsman 1
31UC
3-1/4” Craftsman 2
4 pieces of trim with 10”
excess, Unassembled,
Unmitered
4 pieces of trim and 4 Jamb
Extensions with 10” excess,
Unassembled, Unmitered
31UD
3-1/4” Craftsman 3
30BA
3-1/2” Craftsman 1
31UE
3-1/2” Craftsman 2
Kitted by Order
Optional Stool (with 14" excess)
and Apron available.
31U3
2-1/4” Colonial 1
30AX
2-1/2” Colonial 1
Kitted by Order
30NX
2-1/2” Colonial 2
30NY
2-1/2” Colonial 3
31TY
2-1/2” Colonial 4
31TZ
2-1/2” Colonial 5
31UO
2-1/2” Colonial 6
31U2
3-1/4” Colonial 1
30NW
3-1/2” Colonial 2
31U4
3-1/2” Colonial 3
31U5
3-1/2” Colonial 4
31U6
3-1/2” Colonial 5
31UP
2-1/4” Provincial 1
31UJ
2-1/2” Provincial 1
31UK
2-1/2” Provincial 2
31UL
2-3/4” Provincial 1
31U1
2-3/4” Provincial 2
31UG
3” Provincial 1
RANCH
31UF
31UA
PROVINCIAL
COLONIAL
CRAFTSMAN
Optional Stool and Apron
available.
READY TRIM
KN OCKD OW N
Oak
Ready Trim
Ready Trim
Ready
Ready
Knockdown
Knockdown
Trim
Trim
(lineals)
(lineals)
31UH
3” Provincial 2
31UM
3-1/2” Provincial 1
31UN
4-1/4” Provincial 1
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Pine profiles available prefinished primed, painted or stained.
Oak profiles available prefinished with stain.
Ready Trim Plus
Ready Trim
Ready Trim Plus
with optional Stool
and Apron
A
A
FORMULAS
READY TRIM:
A = FRAME WIDTH + (2 x TRIM WIDTH - .905”)
B = FRAME HEIGHT + (2 x TRIM WIDTH - .874”)
A
READY TRIM PLUS:
A = FRAME WIDTH + (2 x TRIM WIDTH - .625”)
B = FRAME HEIGHT + (2 x TRIM WIDTH - .625”)
B
B
B
READY TRIM PLUS WITH STOOL & APRON:
A = FRAME WIDTH + (2 x TRIM WIDTH - .625”)
B = FRAME HEIGHT + (2 x TRIM WIDTH - .187”)
MINIMUM FRAME DIMENSION ALLOWED IS:
12.000” x 12.000”
MAXIMUM FRAME DIMENSION ALLOWED IS:
62.500” x 74.500” OR 74.500” x 62.500
Ready Trim
(INTERIOR VIEW SHOWN)
Ready Trim Plus
(EXTERIOR VIEW SHOWN)
Ready Trim Plus
w/Stool & Apron
(EXTERIOR VIEW SHOWN)
Rev. 3/16/2015
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-43
INTERIOR TRIM
INSTALLATION
ACCESSORIES
Jamb Extensions
Scale 3" = 1' 0"
IN T E R IO R JAM B E X T E N S IO N S
Accessory
Indiv.
Box
Indiv.
Box
Part No.
No.
Part No.
No.
(Straight) (Straight) (Curved) (Curved)
3/8" Jamb Extension
250R
0654
—
—
3/4" Jamb Extension
—
—
28CU
0BM7
27/32" Jamb Extension
283G
0930
28EA
0BUL
1-1/2" Jamb Extension
301E
0648
30K7
0BUK
2" Jamb Extension with Holes
31J1
—
—
—
2" Jamb Extension
311M
06EN
—
—
2-3/8" Jamb Extension
311Q
06EP
—
—
2-27/32" Jamb Extension
311J
06ER
31A9
0BUJ
3-1/2" Jamb Extension
324A
06ET
32EK
0BUH
3-1/2" Jamb Extension with Holes
3268
0C83
32EL
0BM6
5-1/2" Jamb Extension
30NR
00YX
—
—
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-44
CUSTOM AZEK® EXTERIOR SURROUND TRIM SHAPES
Window Shapes
INSTALLATION
ACCESSORIES
AZEK® exterior composite trim is available for window applications in 1/16" increments provided factory pre-assembled, pre-cut knock-down
(when either or both frame height or width > 75") and in lineal (9') lengths for field assembly. Order pre-assembled and pre-cut by actual
window frame size.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-45
AZEK® EXTERIOR SURROUND TRIM SHAPES
INSTALLATION
ACCESSORIES
AZEK® exterior composite trim is available for window applications in 1/16" increments provided factory pre-assembled, pre-cut knock-down
(when either or both frame height or width > 75") and in lineal (9') lengths for field assembly. Order pre-assembled and pre-cut by actual
window frame size.
Not all shapes are available on every unit. See your local sales representative for availability.
Scale 3" = 1' 0"
Description
2" Brickmould AZEK® trim 9 ft
3-3/8" Flat casing AZEK® Trim 9 ft
4-3/8" Flat casing AZEK® Trim 9 ft
Sill nose AZEK® Trim 9 ft
Crown mould AZEK® Trim 9 ft
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
Part #
0E5B
0E5U
0E5U0001
0E6S
0E5Z
W-IA-46
CUSTOM AZEK® EXTERIOR SURROUND TRIM SHAPES
Entr y and Patio Door Shapes
INSTALLATION
ACCESSORIES
AZEK® exterior composite trim is available for door applications in 1/16" increments provided factory pre-cut in three knock-down pieces (no
sill needed) and in lineal (9’) lengths for field assembly. Order by actual door frame size.
Not all shapes are available on every unit. See your local sales representative for availability.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-47
2" AZEK® BRICKMOULD WITH SILL NOSE
Installation Details
Double-Hung with Brick Veneer
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
• Refer to the appropriate Pella installation instruction for step by step instructions.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-48
2" AZEK® BRICKMOULD WITH SILL NOSE
Installation Details
Casement with Stucco
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
• Refer to the appropriate Pella installation instruction for step by step instructions.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-49
3-3/8" FL AT CASING WITH SILL NOSE AND CROWN
Installation Details
Double-Hung with Wood Siding
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
• Refer to the appropriate Pella installation instruction for step by step instructions.
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-50
3-3/8" FL AT CASING WITH SILL NOSE AND CROWN
Installation Details
Casement with Stucco
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-51
3-3/8" FL AT CASING WITH SILL NOSE AND CROWN
Installation Details
Double-Hung with Brick Veneer
INSTALLATION
ACCESSORIES
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-52
INSTALL ATION SYSTEMS
Renovation — Exterior Pocket Installation
INSTALLATION
ACCESSORIES
H E AD
•
•
•
•
•
Fully assembled standard double-hung window
Slides easily into existing pocket from the exterior
Trim, wall coverings, paint and plaster are usually not disturbed
Eliminates cost and inconvenience of a complete tear-out
Installs from the exterior
JAM B
S ILL
Scale 3" = 1' 0"
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-53
INSTALL ATION SYSTEMS
Renovation — Precision Fit® Interior Pocket Installation
MAKE HEIGHT
1/4"
[6]
INSTALLATION
ACCESSORIES
HEAD
MAKE HEIGHT
H E AD
1/4"
[6]
• Fully assembled Precision Fit® double-hung, awning or
casement window
• Slides easily into existing pocket from the interior
• Trim, wall coverings, paint and plaster are usually not
disturbed
• Eliminates cost and inconvenience of a complete tear-out
• Installs from the interior
SILL
JAM B
JAMB
1/4"
[6]
MAKE WIDTH
Scale 3" = 1' 0"
S I LL
Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com
W-IA-54