Installation Accessories and Applications
Transcription
Installation Accessories and Applications
SECTION DIRECTORY INSTALLATION ACCESSORIES Installation Accessories and Applications Introduction...................................................................................................................................................W-IA-2 Window Attachment Options............................................................................................................W-IA-4 Subsill....................................................................................................................................................W-IA-6 Exterior Mullions..................................................................................................................................W-IA-8 Mullion Cover Application................................................................................................................W-IA-10 Mullion Reinforcements....................................................................................................................W-IA-12 Reinforcing Mullion Application......................................................................................................W-IA-13 Expansion Mullion Cover Application.............................................................................................W-IA-14 Mullion Considerations.....................................................................................................................W-IA-16 Commercial Structural Receptor Mullions......................................................................................W-IA-17 Exterior Trim Applications.................................................................................................................W-IA-22 Frame Expansion Application..........................................................................................................W-IA-25 EnduraClad® Exterior Trim...............................................................................................................W-IA-28 EnduraClad® Exterior Trim Applications........................................................................................W-IA-30 Commercial Replacement Accessories..........................................................................................W-IA-34 Break Metal.........................................................................................................................................W-IA-36 Wood Exterior Mullion Covers.........................................................................................................W-IA-39 Window and Door Subsills and Exterior Trim................................................................................W-IA-40 Interior Casings..................................................................................................................................W-IA-41 Interior Stools and Trim.....................................................................................................................W-IA-42 ReadyTrim...........................................................................................................................................W-IA-43 Interior Jamb Extensions..................................................................................................................W-IA-44 Interior Mullion Covers.....................................................................................................................W-IA-44 AZEK Trim Details Custom Window Shapes..................................................................................................................W-IA-45 Exterior Surround Trim......................................................................................................................W-IA-46 Custom Door Shapes........................................................................................................................W-IA-47 2" Brickmould with Sill......................................................................................................................W-IA-48 Exterior Surround Trim......................................................................................................................W-IA-49 Flat Casing with Sill Nose and Crown.............................................................................................W-IA-50 Pocket Replacment Exterior Pocket Installation...............................................................................................................W-IA-53 Interior Pocket Installation................................................................................................................W-IA-54 Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-1 INTRODUCTION INSTALLATION ACCESSORIES This section presents available installation accessories which, when used in conjunction with proper Pella installation procedures, will provide for a robust installation for single or combination units. Window and door attachment accessories used for both clad and primed wood exterior units are illustrated in this section. Aside from attachment accessories, this section reviews accessories to meet the following requirements: • Combination applications, such as mullion covers, expansion mullion covers, reinforcement mullions and bay and bow accessories. • Interior casings and stools • Subsills • Traditional and flat trim Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-2 ATTACHMENT OPTIONS INSTALLATION ACCESSORIES IN STALLAT IO N ACC E S S O R IE S Indiv. Part No. Box No. Installation Fin Head Drip Cap Curved Head Drip Fin Elliptical Head Drip Fin Quarter Circle Head Drip Fin Head Drip Flashing Head Flashing Receptor Receptor Gasket 6" Installation Clip 8" Installation Clip 42G7 72GW 72Y5 72Y7 72Y6 72WA 72W8 72AK — 5071 5071 0BLA 0BLB — — — 0BMS — 06Y1 0DA9 0635 0B51 T-Subframe Clip 3"-wide Smart Flash® Installation Tape (150' rolls) 6"-wide Smart Flash® Installation Tape (50' rolls) 5027 0DB0 850H0000 0CFV 850H0004 01FM Accessory 72GW 72WA 72W8 72Y5 WO O D S I LL P LAT E S F O R C LAD W IND OWS Indiv. Part No. Box No. 2722 2772 0C79 — Indiv. Part No. Box No. Clad / Wood Subsill 4049 0B13 Subsill Clip 7366 0B14 Replacement Sill Adaptor 70DK — Accessory CM / AW Sill Plate ProLine® Sill Plate S U B S I LLS Accessory Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-3 ATTACHMENT OPTIONS INSTALLATION ACCESSORIES Installation Fin Scale 6" = 1' 0" Scale 3" = 1' 0" H SHIM AND LEVEL UNITS AS REQUIRED CONTINUOUS WOOD BLOCKING, WOOD TRIM, BACKER ROD AND SEALANT BY OTHERS J S Not to scale. To determine window openings for typical installations, add 3/4" to frame width and 3/4" to frame height. • For large size units, out of plumb opening, and/or in masonry construction, the need for additional jamb clearances should be reviewed. • Typical installation details and accessories are shown in the Installation Details and Installation Accessories sections. • Determine if unit performance meets design requirements. Unit performance class and grade are in each product section. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-4 INSTALL ATION SYSTEMS New Construc tion — Punched Opening Clip Installation FRAME ROUGH OPENING 3/8" [10] INSTALLATION ACCESSORIES 2 1/2" [64] FRAME 3/8" [10] ROUGH OPENING HEAD 3/8" [10] FRAME ROUGH OPENING JAMB SILL H To determine window openings for typical installations, add 3/4" to frame width and 3/4" to frame height. • For large size units, out of plumb opening, and/or in masonry construction, the need for additional jamb clearances should be reviewed. • Typical installation details and accessories are shown in the Installation Details and Installation Accessories sections. • Determine if unit performance meets design requirements. Unit performance class and grade are in each product section. J S Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-5 ATTACHMENT OPTION APPLICATIONS Clad Wood Subsill INSTALLATION ACCESSORIES Subsills are recommended for installations where recaulking would be difficult or high weather exposure exists due to the height or location of the building. The need for the subsill weep system is increased where there are multiple units in a given opening. Note: The clad wood subsill is an open weep system. An interior air seal is critical to the performance of this system. Also, DO NOT SEAL the exterior frame expander to the opening. Used with Pella clad windows. Detail at right: Custom 0.05" (1.27) aluminum sill flashing used with clad wood subsill. Scale 3" = 1' 0" • A continuous perimeter line of sealant is required on the interior with clad / wood subsill #4049. • Where the aluminum comes into contact with the cement materials, apply protective coating to separate galvanically incompatible materials. • The clad / wood subsill is a primed, preservative treated wood for use with Pella aluminum clad / wood windows. • The aluminum frame expander covers the front edge of the subsill. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-6 ATTACHMENT OPTION APPLICATIONS INSTALLATION ACCESSORIES L Receptor Application Scale 6" = 1' 0" Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-7 EXTERIOR MULLIONS INSTALLATION ACCESSORIES Bay/Bow Mullion Accessories B AY AN D B O W M U LLIO N ACC E S S O RI ES Bay Wedges 12° 45' 30° 45° Mullion Covers 12° 45' 30° 45° Jamb Covers 12° 45'/30º 45° Indiv. Part No. Box No. 33CX 33CW 34A3 0B19 0B20 0B21 Indiv. Part No. Box No. 72A3 72A4 72A5 0B43 0B37 0C72 Indiv. Part No. 47L2 47K4 See the Architectural Design Manual Bay/Bow section for cross sections of application. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-8 EXTERIOR MULLIONS INSTALLATION ACCESSORIES Mullion Covers MUL L ION COV E RS Mullion Cover A (Frame to Frame) B (Overall Part Dimension) Part Number Thickness (In.) Standard (Direct) 0" 3/8 7217 0.047 1/2" 1/2" 7/8 736M 0.047 1" 1" 1-3/8 736N 0.047 1-1/2" 1-1/2" 1-7/8 736P 0.047 2" 2" 2-3/8 72A9 0.047 2-1/2" 2-1/2" 2-7/8 736T 0.047 3" 3" 3-3/8 736U 0.060 3-1/2" 3-1/2" 3-7/8 736V 0.060 4" 4" 4-3/8 736W 0.060 Custom (Break Metal) Min 5/8" Max 12" B = A + 3/8" 100 Mullion Cover 0.050 For all but direct mullion, dimension A is to inside of bends. Frame to Frame plus 1/4" equals dimension to inside of bends. A = B - 3/8" 3 1/2" Mullion Cover 3" Structure Standard mull covers are extruded aluminum. Standard EnduraClad Mullion Covers A B Break Metal 100 Mullion Cover Structure FRAME RO A = SPCL. 5/8" - 12" [16 - 305] A FRAME RO B B 1 1/2" [38] 2" [51] 2 1/2" [64] 3/8" [9] 7/8" [22] 1 3/8" [35] 1 7/8" [47] 2 3/8" [60] 2 7/8" [73] STANDARD 7217 1/2" Mullion Cover 736M 1" Mullion Cover 736N 1-1/2" Mullion Cover 736P 2" Mullion Cover 72A9 2-1/2" Mullion Cover 736T 3" [76] 3 1/2" [89] 4" [102] 3 3/8" [85] 3 7/8" [98] 4 3/8" [111] 3" Mullion Cover 736U 3-1/2" Mullion Cover 736V 4" Mullion Cover 736W SPCL. 5/8" - 12" [16 - 305] 5/16" [8] 1" [25] 1/2" [13] Break Metal 100 Mullion Cover Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-9 MULLION APPLICATIONS Scale 6" = 1' 0" INSTALLATION ACCESSORIES Scale 3" = 1' 0" SHIM AND LEVEL UNITS AS REQUIRED CUSTOM BREAK METAL MULLION COVER CONTINUOUS WOOD BLOCKING, WOOD TRIM, BACKER ROD AND SEALANT BY OTHERS 100 Mullion cover is fabricated from 0.050" Aluminum for widths of 5/8" to 12" (16 305). (Dimension A is to inside of bends. Frame to Frame plus 1/4" equals dimension to inside of bends.) NOTE: APPLY CONTINUOUS BEAD OF SEALANT TO INSIDE CORNERS OF MULLION COVER BEFORE INSTALLING UNITS. INSTALLATION CLIPS #5071 @ 18" (457) O. C. (REFER TO PAGE (17) FOR ADDITIONAL SPACING INFORMATION 90° MULLION COVER #4994 Use of installation fins #42G7 recommended with 90° mullion. CONTINUOUS INSTALLATION FINS #42G7 SHIM AND LEVEL UNITS AS REQUIRED CONTINUOUS WOOD BLOCKING, WOOD TRIM, BACKER ROD AND SEALANT BY OTHERS Mullion covers are not intended to create a completely waterproof seal. See typical sealant details. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-10 MULLION APPLICATIONS Scale 6" = 1' 0" INSTALLATION ACCESSORIES Scale 3" = 1' 0" INTERIOR WOOD MULLION COVER #2941 CORRUGATED FASTENERS @ 12" (305) O. C. BY OTHERS USED TO JOIN TWO CLAD UNITS WHERE NO MULLION REINFORCEMENT IS REQUIRED MULLION REINFORCEMENT #2941 1" x 1/2" CROWN STAPLE B.O. CONTINUOUS SEALANT BY OTHERS TYPICALLY USED WITH 1/2" (10) MULLION REINFORCEMENT #0A6G NOTE: Apply continuous bead of sealant to inside corners of mullion cover before installing to units. SHIM AND LEVEL UNITS AS REQUIRED CONTINUOUS WOOD BLOCKING, WOOD TRIM, BACKER ROD AND SEALANT BY OTHERS STANDARD SIZE MULLION COVERS AVAILABLE IN 1/2" INCREMENTS FROM 1" to 4" AS NEEDED. 2" (51) MULLION COVER #72A9 NOTE: Apply continuous bead of sealant to inside corners of mullion cover before installing to units. INSTALLATION CLIPS #5071 @ 18" (457) O.C. (REFER TO PAGE 17 FOR ADDITIONAL SPACING INFORMATION) Mullion covers are not intended to create a completely waterproof seal. See typical sealant details. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-11 MULLION REINFORCEMENTS Scale 3" = 1' 0" INSTALLATION ACCESSORIES M U LLIO N R E IN F O R C E M E N T S Accessory Indiv. Part No. Box No. 0A6G 0A6K 512C 000F 512A 72WQ 512B 512D 500P 0EUA 0EUL 00NN0003 0CSL0025 00NN0001 0CUH 00NN0002 00NN0004 0DKM0000 Mullion Reinforcement 1/2" x 3-9/16" Mullion Reinforcement 1/2" x 4-9/16" Clip Mullion Anchor High Performance Mullion Anchor Wood Mullion Anchor Mullion End Splice - 96" Subsill Mullion Anchor Fin Mullion Anchor 20" Plate Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-12 REINFORCING MULLION APPLICATIONS Scale 6" = 1' 0" WOOD TRIM BY OTHERS INSTALLATION ACCESSORIES Scale 3" = 1' 0" 1" x 1/2" Crown Staple B.O. CONTINUOUS SEALANT BY OTHER NOTE: Apply continuous bead of sealant to inside corners of mullion cover before installing to units. 1. Attach 1/2" mullion reinforcements with clips #512C, 000F, 512B or 512D. 2. Can be used either horizontally or vertically for wind load mullion reinforcement. Note: Recommended use is vertically with subsill for large combination assemblies. 3. Do not use as part of building structure. 4. Refer to Combinations Section for wind load information, (max. Length 144"). NOTE: Apply continuous bead of sealant to inside corners of mullion cover before installing to units. WOOD TRIM BY OTHER 1" x 1/2" CROWN STAPLE B.O. CONTINUOUS SEALANT BY OTHER Example Assembly Refer to the Combination Recomendations section and Combination size tables to determine required reinforcement method. FACTORY ASSEMB L E D WO O D MU L L I O N E ND AN C H O R S Rough Framing: Wood, Concrete, CMU, etc. Wood Mullion Anchor Wood Reinforcing mullion 1" to 4" on 1/2" increments. E nd A nc h o rs A tt ac h m e n t: • For Wood Framing: Use 5 #10 x 3" Wood Screws. • For Concrete/CMU: Use 5-3/16" Masonry Screw. Screws have a 1" embedment into wood buck or concrete below subsill. 1 /2 " F IN M U LLI O N E N D AN C H O R S Rough Framing: Wood, Concrete, CMU, etc. Fin Anchor #512D 1/2" x 3-9/16" Reinforcing mullion #0A6G Fin Anchor #512D E n d An chors Atta c hm e n t: • For Wood: Use 5 - #10 x 3" Wood Screws. • For Concrete/ CMU: Use 3/16" Masonry Screw. The 1/2" mullion assembly with end anchors 512D (fin mullion anchor), 000F (high performance fin mullion anchor) or 512A (wood fin mullion anchor) allow for installation of combinations that are assembled prior to being placed in the opening. Combinations assembled with this method should not exceed 144 square feet in total size. Always handle combinations in vertical orientation. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-13 EXPANSION MULLION COVER APPLICATIONS T-Expansion Mullion Application Expansion Mullion Cover Scale 6" = 1' 0" INSTALLATION ACCESSORIES Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-14 EXPANSION MULLION COVER APPLICATIONS INSTALLATION ACCESSORIES Scale 3" = 1' 0" Clip Installation Fin Installation FRAME FRAME VARIES 3/8" [10] FRAME 3/8" [10] 3/8" [10] EXPANSION MULLION COVER 72HF VARIES FRAME 3/8" [10] SHIM AND LEVEL UNITS AS REQUIRED CONTINUOUS WOOD BLOCKING, WOOD TRIM, BACKER ROD AND SEALANT BY OTHERS 1" [25] Clip Installation Varies FRAME FRAME 3/8" [10] INSTALLATION CLIPS #5071 @ 18" (457) O. C. 2" [51] Fin Installation FRAME VARIES 3/8" [10] 1/2" [13] EXPANSION MULLION COVER WITH VINYL BULB GASKET 1AAF FRAME 1/2" [13] INSTALLATION CLIPS #5071 @ 18" (457) O. C. 3/8" [9] CONTINUOUS WOOD BLOCKING, WOOD TRIM, BACKER ROD AND SEALANT BY OTHERS 1 1/4" [32] 1 5/8" [42] NOTE: APPLY CONTINUOUS BEAD OF SEALANT TO INSIDE CORNERS OF MULLION COVER BEFORE INSTALLING UNITS. Rev. 02/24/2016 Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-15 INSTALL ATION SYSTEMS New Construc tion — Punched Opening Mulling Considerations INSTALLATION ACCESSORIES M U LLI O N R E I N F O R C E M E NT 1 /2 " X 3 - 9 /1 6 " Burlington Apartments, Portland, OR Ankrom Moisan Associated Architects These recommendations apply to a typical grouping of any combination of window units that form a fourway mullion intersection. STAN DAR D M U LLI O N COVER Refer to single-unit opening recommendations in addition to the following: 1 1/2" clearance is recommended at each jamb in masonry construction and/or when window opening height or width is 10' or greater. 2 All four-way mullion intersections require reinforcing mullion in one direction (either vertically or horizontally). See mullion load chart pages in the Installation section on PellaADM.com. 3 Check combination (joining) mullion limitation for specified wind loading. Combination (joining) and reinforcing mullions are shown on the mullion load chart pages in the Installation section on PellaADM. com. 4 Subsill systems that weep incidental moisture to the exterior are recommended for water management in openings where the potential for water infiltration is increased and may not be adequately managed by the building weather barrier, flashings and drainage system. Sample conditions include, but are not limited to: increased level of exposure due to multi-story construction, high weather exposure, recaulking would be difficult or unlikely, non-standard installation methods, or when there are multiple units joined within the opening. M U LLI O N COV E R ( R AN GE : F R AM E TO F R AM E 1 " TO 4") E X PAN S I O N M U LLIO N COVER If lower unit is venting, horizontal reinforcing mullion may be required to carry weight of upper units. See Weight Limitations Over Windows information in the Installation and Performance section on PellaADM.com. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-16 INSTALL ATION SYSTEMS New Construc tion — Punched Opening L-Receptor and 2" Ver tical Struc tural Receptor INSTALLATION ACCESSORIES L-Receptor 72AK L-Receptor Clip 5027 Bulb Gasket 0SA9 HEAD CLAD / WOOD SUBSILL 4049 & CLIP 7366 SILL 2" Structural Receptor Mullion 0APK JAMB VERTICAL MULLION Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-17 INSTALL ATION SYSTEMS New Construc tion — Store Fronts 1 3/4" [44] INSTALLATION ACCESSORIES 2" [51] Horizontal Receptor Mullion 1 3/4" Structure 50E3 Vertical Receptor Mullion 2" Structure 50E5 Burlington Apartments, Portland, OR Ankrom Moisan Associated Architects 2" [51] 1 1 1/2" Mullion Cover 736B 2 4 Vertical Mullion Window Wall Channel 2" Structure 50E4 Horizontal Mullion Expansion Cover with Gasket 1AAF 5 Standard Frame Expander Elevation 6 3 Refer to single-unit opening recommendations in addition to the following: • 1/2" clearance is recommended at each jamb in masonry construction and/or when window opening height or width is 10' or greater. • All four-way mullion intersections require reinforcing mullion in one direction (either vertically or horizontally). See mullion load chart pages in the Installation section on PellaADM.com. • Check combination (joining) mullion limitation for specified wind loading. Combination (joining) and reinforcing mullions are shown on the mullion load chart pages in the Installation section on PellaADM.com. • Subsill systems that weep incidental moisture to the exterior are recommended for water management in openings where the potential for water infiltration is increased and may not be adequately managed by the building weather barrier, flashings and drainage system. Sample conditions include, but are not limited to: increased level of exposure due to multi-story construction, high weather exposure, recaulking would be difficult or unlikely, non-standard installation methods, or when there are multiple units joined within the opening. If lower unit is venting, horizontal reinforcing mullion may be required to carry weight of upper units. See Weight Limitations Over Windows information in the Installation and Performance section on PellaADM.com. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-18 INSTALL ATION SYSTEMS New Construc tion — Store Fronts INSTALLATION ACCESSORIES 4 1 HEAD JAMB 5 2 HORIZONTAL MULLION VERTICAL MULLION 6 3 SILL SILL Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-19 INSTALL ATION SYSTEMS New Construc tion — Window Walls INSTALLATION ACCESSORIES 1 1 3/4" [44] 2 5 4 6 Horizontal Receptor Mullion 1 3/4" Structure 50E3 2" [51] 3 E L E VAT I O N Vertical Receptor Mullion 2" Structure 50E5 Environmental Nature Center, Newport Beach, CA; LPA Inc. LEED® Platinum Photo © Costea Photography, Inc. • 1/2" clearance is recommended at each jamb in masonry construction and/or when window opening height or width is 10' or greater. • All four-way mullion intersections require reinforcing mullion in one direction (either vertically or horizontally). See mullion load chart pages in the Installation section on PellaADM.com. • Check combination (joining) mullion limitation for specified wind loading. Combination (joining) and reinforcing mullions are shown on the mullion load chart pages in the Installation section on PellaADM.com. • Subsill systems that weep incidental moisture to the exterior are recommended for water management in openings where the potential for water infiltration is increased and may not be adequately managed by the building weather barrier, flashings and drainage system. Sample conditions include, but are not limited to: increased level of exposure due to multi-story construction, high weather exposure, recaulking would be difficult or unlikely, non-standard installation methods, or when there are multiple units joined within the opening. 2" [51] Refer to single-unit opening recommendations in addition to the following: Vertical Mullion Window Wall Channel 2" Structure 50E4 1 1/2" Mullion Cover 736B Horizontal Mullion Expansion Cover with Gasket 1AAF Standard Frame Expander If lower unit is venting, horizontal reinforcing mullion may be required to carry weight of upper units. See Weight Limitations Over Windows information in the Installation and Performance section on PellaADM.com. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-20 INSTALL ATION SYSTEMS New Construc tion — Window Walls INSTALLATION ACCESSORIES 4 1 HEAD 2 JAMB 5 HORIZONTAL MULLION 3 VERTICAL MULLION - STEEL OPTION 6 SILL Scale 3" = 1' 0" VERTICAL MULLION Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-21 EXTERIOR TRIM - FIELD APPLIED APPLICATION Traditional Trim and Clad Sill Nose Siding Applications Scale 6" = 1' 0" INSTALLATION ACCESSORIES Scale 3" = 1' 0" SHIM AND LEVEL UNITS AS REQUIRED CONTINUOUS WOOD BLOCKING, WOOD TRIM, BACKER ROD AND SEALANT BY OTHERS Aluminum traditional flat trim is to be used in frame construction with standard installation fins only. Maximum length is 8'. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-22 EXTERIOR TRIM - FIELD APPLIED APPLICATION Traditional Trim and Clad Sill Nose Brick Veneer Applications INSTALLATION ACCESSORIES SHIM AND LEVEL UNITS AS REQUIRED CONTINUOUS WOOD BLOCKING, WOOD TRIM, BACKER ROD AND SEALANT BY OTHERS FIE L D APP L IED EXTE RI O R TRI M Accessory Traditional Trim 3-1/2" Flat Trim Head 3-1/2" Flat Trim Jamb 1/2" Clad Sill Nose Indiv. Part No. Box No. 72D6 72D4 72D5 72E0 72D8 0DC3 0DC4 0DC5 0DC6 Aluminum traditional flat trim is to be used in frame construction with standard installation fins only. Maximum length is 8'. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-23 EXTERIOR TRIM - FIELD APPLIED APPLICATION Flat Trim with Clad Sill Nose Siding Applications Scale 6" = 1' 0" INSTALLATION ACCESSORIES Scale 3" = 1' 0" Aluminum traditional flat trim is to be used in frame construction with standard installation fins only. Maximum length is 8'. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-24 EXTERIOR TRIM - FRAME EXPANDER Frame Expander Frame Expander Receptor Scale 6" = 1' 0" Scale 3" = 1' 0" PELLA Window and Door Installation Sealant. and Water Resistant Backer Rod and Sealant. by Others 1 1/16" [27] 5/16" [8] 1 1/4" [32] 1/2" [13] INSTALLATION ACCESSORIES Low Expansion, Low Pressure Polyurethane Insulating Window and Door Sealant. (do not use high pressure or latex foam.) INSTALLATION CLIPS @ 18" (457) O.C. Continuous Wood Blocking, Wood Trim Continuous Bead of Sealant by Others. 1" FRAME EXPANDER FRAME EXPANDER RECEPTOR FRAME EXPANDER RECEPTOR Used to receive and trim outside edge of frame expander as an alternate to face-screwing edge into blocking. Return leg can be field-trimmed as required. FRAME ROUGH OPENING MASONRY OPENING For use with aluminum-clad wood windows Provides the look of flat trim Receptor available for wide trims Paint finish that matches windows Available with or without brickmould Custom brickmould profiles available Straight or curved Trim to frame opening Factory Supplied Frame Expander Kits available, trim is processed and notched to length per unit configuration, saves time and scrap on the job site. 4 1/4" [108] HEAD 1 3/16" [30] 1 15/16" [49] 2 11/16" [68] Used at head, jamb and/or sill. 1" Frame Expander 4" Frame Expander MASONRY OPENING 2 1/2" Frame Expander FRAME 3/4" [19] 3/8" [10] 1 3/4" Frame Expander ROUGH OPENING 6" [152] • • • • • • • • • 3/8" [10] Application: New Construction or Renovation JAMB 6" Frame Expander Continuous Wood Blocking, Wood Trim Continuous Bead of Sealant by Others. INSTALLATION CLIPS @ 18" (457) O.C. PELLA Window and Door Installation Sealant. and Water Resistant Backer Rod and Sealant. by Others 1" FRAME EXPANDER FRAME EXPANDER RECEPTOR Low Expansion, Low Pressure Polyurethane Insulating Window and Door Sealant. (do not use high pressure or latex foam.) Shim Units Plumb and Level as Required Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-25 EXTERIOR TRIM - NEW CONSTRUCTION APPLICATION Aluminum Brickmould Aluminum Brickmould Clip INSTALLATION ACCESSORIES 1 3/16" [30] 1 15/16" [49] 2 1/2" 47D6 1 3/4" 47D5 1" 47D4 ROUGH OPENING 3/8" [10] FRAME 4" 47E3 MASONRY OPENING 6" 47D3 2 11/16" [68] 4 1/4" [108] 6" [152] 3 3/4" [95] 3/8" [10] Frame Expander HEAD 1 7/8" 7SBP - 0SBN FRAME 1 1/2" [37] 1 11/16" [43] 1 3/16" [30] 3/8" [10] 2 1/4" [57] 15/16" [23] ROUGH OPENING 1 7/8" 72AP - 72AQ MASONRY OPENING 1 1/2" [37] JAMB 1 7/8" [48] 1 7/8" [48] 1 1/16" [27] 1 7/16" [36] ROUGH OPENING 3/8" [10] FRAME 2 1/16" 72AN - 72AQ 5/8" [16] 1 5/16" [33] MASONRY OPENING 2 1/16" [52] 7/8" [22] 1 1/2" [38] 1 1/2" 7SB7 - 0SB8 1 5/16" 7SB1 - 0SBQ 1 1/16" [27] 1 5/8" [41] 1 1/2" [38] 3 3/4" [95] 3/8" [10] Custom Brickmould with Clip 1 11/16" 7SBX - 0SBN SILL Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-26 EXTERIOR TRIM - RENOVATION APPLICATION INSTALLATION ACCESSORIES Aluminum Brickmould Aluminum Brickmould Clip Existing Wall Construction 1 3/4" 47D5 1" 47D4 3/8" [10] FRAME 1 3/16" [30] 1 15/16" [49] 2 1/2" 47D6 ROUGH OPENING 4" 47E3 MASONRY OPENING 6" 47D3 2 11/16" [68] 4 1/4" [108] 6" [152] 1 1/2" [38] 3/8" [10] Frame Expander HEAD Existing Wall Construction 2 1/4" [57] FRAME Shim, Level & Plumb Units as Required 1 1/2" [37] 1 11/16" [43] 1 3/16" [30] 1 1/2" ROUGH OPENING [14] 3/8" [10] FRAME MASONRY OPENING 1 7/8" 7SBP - 0SBN 15/16" [23] Wood Blocking, Trim and Sealant by Others. JAMB 1 1/2" [37] 1 7/8" [48] 1 7/8" [48] 1 7/8" 72AP - 72AQ 1 5/16" [33] 3/8" [10] 1 7/16" [36] 1 1/16" [27] 5/8" [16] ROUGH OPENING 2 1/16" 72AN - 72AQ MASONRY OPENING 2 1/16" [52] 7/8" [22] 1 1/2" [38] 1 1/2" 7SB7 - 0SB8 1 5/16" 7SB1 - 0SBQ 1 1/16" [27] 1 5/8" [41] 1 1/2" [38] 1 1/2" [38] 3/8" [10] Custom Brickmould with Clip Existing Wall Construction 1 11/16" 7SBX - 0SBN SILL Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-27 ENDURACL AD® EXTERIOR TRIM - FACTORY APPLIED INSTALLATION ACCESSORIES Trim Profiles Factory Installed Guidelines • Maximum size is 138" x 101" 1/2" Sill Nose • Trim comes assembled and installed on unit and includes endcaps and fins as neccessary. 1" Sill Nose 2" Sill Nose 3-1/2" Flat Casing S I LL N O S E CO M PAT I B ILITY • Factory Applied Trim is available on all Aluminum Clad products, including curved and angled shapes, with the following exceptions: Architect Series® and Designer Series® four-panel patio doors ProLine® hinged and sliding doors Precision Fit® pocket replacement windows Bay / Bow windows 1-1/2" Brickmould ● ● ● 3-1/2" Brickmould ● ● ● 3-1/2"Flat Casing ● ● ● Jefferson ● ● Monroe ● ● ● Architect Series® Specialty windows HEAD DRIP CAP Monroe 50NN 1 9/16" [40] 1 7/16" [36] 11/16" [18] 11/16" [18] 3/8" [10] 11/16" [18] Standard 50GU 5/16" [8] 11/16" [18] 1/4" [6] 2 5/16" [58] 2" [50] Jefferson 50NL 3/8" [10] 1 11/16" [43] 2 1/4" [57] 3 1/2" Flat Casing 50NM 1 3/8" [34] Brickmould 70F5 Monroe 50GF 1/2" Nose 50GZ 2" [51] 1" Nose w/ Nose Extension 50H0, 50H8 NEW CONSTRUCTION FIN Standard Clad Trim Fin 70F2 2 5/8" [67] 1 3/16" [30] 1 3/16" [30] Standard Clad Trim Fin 50HB 3 1/2" Flat Casing 50GJ 13/16" [21] 1 3/16" [30] 1" 1 3/16" [25] [30] 1" [25] 5/16" [8] Jefferson 50GC 3 1/2" Brickmould 50G9 SILL NOSE 1/2" [13] 3 1/2" [89] 3 1/2" [89] 2 3/16" [55] 1 1/2" [37] 1 1/2" [37] 1 9/16" [40] 3 1/2" [89] TRIM PROFILES 2" Nose w/ Nose Extension 50H1, 50H8 3 1/2" Flat Casing 50MD RENOVATION REPLACEMENT FIN Standard Clad Trim Sill Fin 70F4 Standard Clad Trim Replacement Fin 50HE Clad Trim Replacement Fin 50H9 Standard Clad Trim Replacement Sill Fin 50HJ Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-28 ENDURACL AD® EXTERIOR TRIM - FACTORY APPLIED INSTALLATION ACCESSORIES Ordering Information Head to Jamb joints are mitered except for 3-1/2" Flat Casing, which uses butt joints and head end caps. All applied trim includes end caps as needed and installation fin as determined by your selections (new construction or replacement/renovation). 3-1/2" Trim fins are used for flashing purposes only, and are not intended for anchoring/attachement of the unit. Performing whole unit field application of EnduraClad Exterior Trim in the field may result in voiding product warranties. MO. FR. A C FR. MO. B A A&B Jamb pieces are mitered to the slope of the sill. The sill is notched where the jambs meet the sill. Sill nose extensions are included where needed. Sill end caps are included.. B Head 3-1/2" Flat Casing Sill + 1.18" + 3.21" + 3.21" + 3.21" + 1.18" — — + 3.21" — — FRAME TO EXTE RI O R TRI M 1-1/2" Brickmould + 1.18" 3-1/2" Brickmould + 3.21" 3-1/2" Flat Casing + 3.21" Jefferson + 3.21" Monroe + 1.18" C 1/2" Sill Nose 1" Sill Nose + 1.18" + 1.18" + 1.18" — — + 1.892" + 1.892" + 1.892" + 1.892" + 1.892" 2" Sill Nose + 2.892" + 2.892" + 2.892" + 2.892" + 2.892" C A Jamb (single) These dimensions do NOT include 3/8" per side for sealant, foam and backer rod, only the dimension of the trim beyond the unit frame. All example images on this page use 1-1/2" Brickmould with 1/2" Sill nose Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-29 ENDURACL AD® EXTERIOR TRIM - FACTORY APPLIED APPLICATION INSTALLATION Brickmould with 1/2" Sill Nose ACCESSORIES Siding Applications Scale 6" = 1' 0" Scale 3" = 1' 0" FRAME HEAD BRICKMOULD ROUGH OPENING SHIM AND LEVEL UNITS AS REQUIRED CONTINUOUS WOOD BLOCKING, WOOD TRIM, BACKER ROD AND SEALANT BY OTHERS FRAME 15/16" [23] 3/8" [10] 1/8" [3] 5/16" [8] 1 1/2" [37] 1 3/16" [30] ROUGH OPENING 1 5/16" [34] 15/16" [24] 3/8" [10] 1/8" [3] 1 5/8" [42] FRAME 15/16" [23] 3/8" [10] 9/16" [15] 1/16" [2] 1 3/16" [29] 15/16" [25] 1/8" [3] 15/16" [25] 1/2" [13] 5/16" [8] 1/2" SILL NOSE ROUGH OPENING JAMB 7/8" [23] 13/16" [21] SILL Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-30 ENDURACL AD® EXTERIOR TRIM - FACTORY APPLIED APPLICATION INSTALLATION Brickmould with 1/2" Sill Nose ACCESSORIES Brick Veneer Applications Scale 6" = 1' 0" Scale 3" = 1' 0" FRAME 3/8" [10] 1 3/16" [30] ROUGH OPENING Standard MASONRY OPENING 1/4" [6] 11/16" [18] 3/8" [10] 1 11/16" [43] HEAD 3/8" [10] 1 3/16" [30] Protect units and trim from excess mortar when placing brick around opening. FRAME BRICKMOULD ROUGH OPENING MASONRY OPENING 1 3/16" [30] 5/16" [8] 1 1/2" [37] 3/8" [10] 1 5/16" [34] 1 5/8" [42] FRAME ROUGH OPENING 3/8" [10] 3/8" [10] 1 3/16" [29] MASONRY OPENING 9/16" [15] 1/16" [2] 1 3/16" [29] 15/16" [25] 15/16" [25] 1/2" [13] 5/16" [8] JAMB 7/8" [23] 13/16" [21] 1/2" SILL NOSE SHIM AND LEVEL UNITS AS REQUIRED CONTINUOUS WOOD BLOCKING, WOOD TRIM, BACKER ROD AND SEALANT BY OTHERS SILL Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-31 ENDURACL AD® EXTERIOR TRIM - FACTORY APPLIED APPLICATION INSTALLATION Brickmould with 1/2" Sill Nose ACCESSORIES Replacement Brick Veneer Applications Scale 6" = 1' 0" 3/8" [10] FRAME MASONRY OPENING 1 3/16" [30] HEAD BRICKMOULD 3/8" [10] FRAME ROUGH OPENING MASONRY OPENING 1 3/16" [30] 3/8" [10] 5/16" [8] 1 1/2" [37] 1 5/8" [42] ROUGH OPENING 1 3/16" [30] 3/8" [10] Scale 3" = 1' 0" 13/16" [21] FRAME ROUGH OPENING 3/8" [10] 3/8" [10] 7/8" [23] 1 3/16" [29] 9/16" [15] 1/16" [2] 1 3/16" [29] 15/16" [25] 1/2" [13] 5/16" [8] 1/2" SILL NOSE MASONRY OPENING JAMB SHIM AND LEVEL UNITS AS REQUIRED CONTINUOUS WOOD BLOCKING, WOOD TRIM, BACKER ROD AND SEALANT BY OTHERS SILL Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-32 ATTACHMENT OPTIONS INSTALLATION ACCESSORIES Receptor and Subframe Systems T-Subframe Application 2 7/8" [73] MAX. 5/8" [16] 3/8" [10] HEAD FRAME SUBFRAME 3 1/2" [89] T-SUBFRAME HEAD #72F6 MASONRY OPENING CLIP #7363 EXISTING OPENING 3 1/2" [89] Existing Wall Construction and Steel Frame. CLIP #7363 6 1/2" [165] Existing Wall Construction and Steel Frame. FRAME FRAME JAMB SILL *NOTE: Subframe leg may be field-cut as required. T-SUBFRAME SILL #73H8 2 1/4" [58] MAX. 3" [76] 3/4" [19] SUBFRAME SUBFRAME 2 7/8" [73] MAX. 5/8" [16] 3/8" [10] EXISTING OPENING EXISTING OPENING PACKAGE #0DB00000: WINDOW CLIP #5027 AND #8x5/8" PAN HEAD PHILLIPS SCREW MASONRY OPENING SUBFRAME CLIP #7363 MASONRY OPENING T-SUBFRAME JAMB #73H9 Existing Wall Construction and Steel Frame. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-33 ATTACHMENT OPTIONS INSTALLATION ACCESSORIES Receptor and Subframe Systems Standard Subframe Application Continuous Perimeter Sealant (See installation instructions) *NOTE: Subframe leg may be field-cut as required. 8" [204] HEAD FRAME SUBFRAME EXISTING OPENING SUBFRAME CLIP #7363 MASONRY OPENING 3 1/2" [89] 2 7/8" [73] MAX. 5/8" [16] 3/8" [10] EXISTING WALL CONSTRUCTION AND WOOD WINDOW FRAME SUBFRAME HEAD #7355 FRAME FRAME SUBFRAME SUBFRAME EXISTING OPENING EXISTING OPENING JAMB SILL 3 9/16" [91] MAX. 3 9/16" [90] PACKAGE #0B050000: WINDOW CLIP #5087 AND #8x5/8" PAN HEAD PHILLIPS SCREW MASONRY OPENING SUBFRAME JAMB #7357 MASONRY OPENING 3 1/2" [89] 2 7/8" [73] MAX. 5/8" [16] 3/8" [10] EXISTING WALL CONSTRUCTION AND WOOD WINDOW FRAME SUBFRAME SILL #7360 EXISTING WALL CONSTRUCTION AND WOOD WINDOW FRAME Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-34 ATTACHMENT OPTIONS Receptor and Subframe Systems Expander and Trim Application INSTALLATION ACCESSORIES Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-35 BREAK METAL INSTALLATION ACCESSORIES Covers and Trim The Pella accessory system includes all of the most-often-specified standard items shown in this Architectural Design Manual as well as other specials shown here. In addition, completely custom / special installation, panning, and trim systems can be designed and fabricated by Pella for specific project requirements. Shapes shown on the next two pages can be ordered to various dimensions needed. Consult your local Pella sales representative. MUL L ION COVERS MUL L ION TRIM S ILL T R IM H EAD JAMB TRIM Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-36 BREAK METAL Sill Flashing INSTALLATION ACCESSORIES S ILL FL ASHIN G AT TACHMEN T CL IP Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-37 BREAK METAL Sill Flashing Application INSTALLATION ACCESSORIES Custom A luminum Sill F las h ing •Custom 0.050" (1.27) aluminum sill flashings can be fabricated to specifications as required. Detail shows typical conditions where custom aluminum sill flashing might be used. •The use of this sill flashing is recommended only in climates where thermal conductance is not likely to occur. •Where aluminum comes into contact with cement materials or steel, apply protective coating to separate galvanically incompatible materials. Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-38 WOOD EXTERIOR INSTALLATION ACCESSORIES Exterior Mullion Covers I N T E R I O R M U LLI O N COV E R S Accessory Casement Interior Double-Hung Interior Bay Interior Indiv. Part No. Box No. 26A9 2600 3015 09GK 0BMU 0B42 Indiv. Part No. Box No. 2903 2942 29T0 3046 3149 0B97 0921 — 06M2 0B44 E X T E R I O R M U LLI O N COV E R S Accessory Casement Exterior–Horizontal Casement Exterior–Vertical Double-Hung Exterior–Horizontal Double-Hung Exterior–Vertical Bow Casement Exterior See the Bay/Bow Section in the Architectural Design Manual for application details. Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-39 WOOD EXTERIOR Brickmould and Subsill INSTALLATION ACCESSORIES SUBSIL L S AND E XTE RI O R TRI M Accessory 3-1/2" with Rabbet 3-1/2 " without Rabbet 3-1/2" Flat Casing with Rabbet 1-7/8" Curved with Rabbet 1-7/8" Curved without Rabbet 1-7/8" with Rabbet 1-7/8" without Rabbet Accessory 1-1/8" Subsill 1-7/8" Subsill Double-Hung Sill Nose Sill Flashing Indiv. Part No. Box No. 38L6 38L5 380R 33M4 33P2 3443 3419 0F08 0F07 0DAZ — — 0B96 0BB0 Indiv. Part No. Box No. 3544 250H 3315 — 0920 093H 0C29 0D98 Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-40 INTERIOR TRIM INSTALLATION ACCESSORIES 2 1/2" [64] 2 1/2" [64] 2 1/2" 1 30AY, 30BD 2 1/2" 2 31U7 2 1/2" 3 31UF 3" 1 31UA 5/8" [16] 5/8" [16] 3 1/2" [89] 5/8" [16] 3 1/4" [83] 5/8" [16] 5/8" [16] 7/16" [11] 3" [76] 5/8" [16] 2 1/2" [64] RANCH 3 1/2" [89] Casing 3 1/4" 1 31U9 3 1/2" 1 30U7, 30UA 3 1/2" 2 31U8 5/8" [16] 3 1/4" [83] 3 1/4" [83] 3 1/4" 1 31UB 3 1/4" 2 31UC 5/8" [16] 5/8" [16] 3 1/2" [89] 5/8" [16] 3 1/2" [89] 5/8" [16] 3 1/4" [83] CRAFTSMAN 3 1/4" 3 31UD 3 1/2" 1 30BA 3 1/2" 2 31UE 5/8" [16] 5/8" [16] 5/8" [16] 5/8" [16] 5/8" [16] 5/8" [16] 2 1/2" [64] 2 1/2" [64] 2 1/2" [64] 2 1/2" [64] 2 1/2" [64] 2 1/2" [64] COLONIAL 2 1/2" 1 30AX, 30BB 5/8" [16] 2 1/2" 3 30NY 5/8" [16] 2 1/2" 5 31TZ 3/4" [19] 3/4" [19] 5/8" [16] 3 1/2" 1 30AZ, 312R 3 1/2" 2 30NW, 312S 3 1/2" 3 31U4 2 1/2" [64] 2 1/2" [64] 2 1/2" 1 31UJ 3/4" [19] 3/4" [19] 2 1/2" 2 31UK 2 3/4" 1 31UL 3 1/2" 4 31U5 5/8" [16] 3 1/2" 5 31U6 3/4" [19] 5/8" [16] 3" [76] 5/8" [16] 2 3/4" [70] 5/8" [16] 2 3/4" [70] 5/8" [16] 2 1/4" [57] PROVINCIAL 2 3/4" 2 31U1 2 1/2" 6 31U0 3 1/2" [89] 3 1/4" [83] 3 1/4" 1 31U2 2 1/4" 1 31UP 2 1/2" 4 31TY 3 1/2" [89] 5/8" [16] 2 1/2" 2 30NX, 312Q 3" 1 31UG 3" 2 31UH 5/8" [16] 4 1/4" [108] 2 1/4" 1 31U3 3 1/2" [89] 2 1/4" [57] 5/8" [16] 3 1/2" 1 31UM 4 1/4" 1 31UN Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-41 INTERIOR TRIM INSTALLATION ACCESSORIES Trim Accessories Cove Trim 1 60U6 / 60U9 Lattice 1 31VP Lattice 2 31VV 5 1/8" [129] 3 5/8" [91] Lattice 3 260A Lattice 4 260P Lattice 5 261C 1/2" [13] 1/2" [13] STOOL 1/4" [6] 1 3/8" [36] 2 1/2" [64] Quarter Round 2 31VQ Quarter Round 1 30U5 / 30U8 1/2" [12] 3/4" [19] 3/4" [19] 3/4" [19] 3/4" [19] 3/4" [19] 1/2" [13] 1/4" [6] COVE MOULD 5 1/4" [133] BASE TRIM 1/4" [6] 5/8" [16] LATTICE 1 5/8" [41] Round 1 32WH 5/8" [16] 1 5/8" [41] Ogee 1 32WJ 1/2" [13] 5/8" [16] 1/8" [3] 2 7/16" [62] Ogee 1 31VR 1/2" [13] 2 7/16" [62] Round 1 3146 1/8" [3] 5/8" [16] 5/8" [16] 4 9/16" Jamb 6 9/16" Jamb Ogee 2 31VS Round 2 30LC Colonial 3 31VF Colonial 2 31VL Colonial 4 30VG 1 5/8" [41] Ranch 1 31VK 1 5/8" [41] 5/8" [16] 1 3/8" [35] 1 1/4" [32] 1 13/16" [47] 5/8" [16] 1 3/4" [44] 5/8" [16] 3/8" [10] 3/8" [10] 5/8" [16] Colonial 1 30VM 7/8" [22] 1 5/8" [41] Ogee 2 31VW STOP 7/8" [22] 2 5/8" [67] 1/8" [3] 1 5/8" [41] Round 1 30VJ Round 2 31VH 3/4" [19] 1/2" [12] Round 2 3204 2 5/8" [67] 1/8" [3] 4 7/16" [113] 5/8" [16] 5/8" [16] 4 7/16" [113] Square 1 31VN SPREAD MULLION COVER 5/16" [9] 1/2" Mullion 1 260A 1" Mullion 1 260B 1 1/2" Mullion 1 260D 2" Mullion 1 260N 2 1/2" Mullion 1 260P 3" Mullion 1 260V 3 1/2" Mullion 1 261B 1/4" [6] 5 1/8" [129] 1/4" [6] 4 5/8" [117] 1/4" [6] 4 1/8" [104] 1/4" [6] 1/4" [6] 3 5/8" [91] 1/4" [6] 1/4" [6] 2 5/8" [66] 1 3/8" [36] 1/4" [6] DOUBLE-HUNG #2600 2 1/8" [53] CASEMENT #26A9 3 1/8" [79] 1 5/32" [29] 1 25/32" [45] 1/4" [6] 4" Mullion 1 261C Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-42 INTERIOR TRIM INSTALLATION ACCESSORIES ReadyTrim READY TRIM RE A DY TRI M P LU S Pine For use with or without Jamb Extensions Save time when Jamb Extensions are needed 4 pieces of trim, PreAssembled 4 pieces of trim, 4 Jamb Extensions, 4 Cover Strips, Pre-Assembled Packaged by unit, max 3 per carton R E ADY T R IM P R O F ILE O PT IO N S Packaged by unit, max 1 per carton 30AY 2-1/2” Ranch 1 31U7 2-1/2” Ranch 2 2-1/2” Ranch 3 3” Ranch 1 31U9 3-1/4” Ranch 1 RE A DY TRI M P LU S K NO CK D O W N 30U7 3-1/2” Ranch 1 31U8 3-1/2” Ranch 2 Pre-measured and kitted to save time Pre-measured and kitted to save time 31UB 3-1/4” Craftsman 1 31UC 3-1/4” Craftsman 2 4 pieces of trim with 10” excess, Unassembled, Unmitered 4 pieces of trim and 4 Jamb Extensions with 10” excess, Unassembled, Unmitered 31UD 3-1/4” Craftsman 3 30BA 3-1/2” Craftsman 1 31UE 3-1/2” Craftsman 2 Kitted by Order Optional Stool (with 14" excess) and Apron available. 31U3 2-1/4” Colonial 1 30AX 2-1/2” Colonial 1 Kitted by Order 30NX 2-1/2” Colonial 2 30NY 2-1/2” Colonial 3 31TY 2-1/2” Colonial 4 31TZ 2-1/2” Colonial 5 31UO 2-1/2” Colonial 6 31U2 3-1/4” Colonial 1 30NW 3-1/2” Colonial 2 31U4 3-1/2” Colonial 3 31U5 3-1/2” Colonial 4 31U6 3-1/2” Colonial 5 31UP 2-1/4” Provincial 1 31UJ 2-1/2” Provincial 1 31UK 2-1/2” Provincial 2 31UL 2-3/4” Provincial 1 31U1 2-3/4” Provincial 2 31UG 3” Provincial 1 RANCH 31UF 31UA PROVINCIAL COLONIAL CRAFTSMAN Optional Stool and Apron available. READY TRIM KN OCKD OW N Oak Ready Trim Ready Trim Ready Ready Knockdown Knockdown Trim Trim (lineals) (lineals) 31UH 3” Provincial 2 31UM 3-1/2” Provincial 1 31UN 4-1/4” Provincial 1 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Pine profiles available prefinished primed, painted or stained. Oak profiles available prefinished with stain. Ready Trim Plus Ready Trim Ready Trim Plus with optional Stool and Apron A A FORMULAS READY TRIM: A = FRAME WIDTH + (2 x TRIM WIDTH - .905”) B = FRAME HEIGHT + (2 x TRIM WIDTH - .874”) A READY TRIM PLUS: A = FRAME WIDTH + (2 x TRIM WIDTH - .625”) B = FRAME HEIGHT + (2 x TRIM WIDTH - .625”) B B B READY TRIM PLUS WITH STOOL & APRON: A = FRAME WIDTH + (2 x TRIM WIDTH - .625”) B = FRAME HEIGHT + (2 x TRIM WIDTH - .187”) MINIMUM FRAME DIMENSION ALLOWED IS: 12.000” x 12.000” MAXIMUM FRAME DIMENSION ALLOWED IS: 62.500” x 74.500” OR 74.500” x 62.500 Ready Trim (INTERIOR VIEW SHOWN) Ready Trim Plus (EXTERIOR VIEW SHOWN) Ready Trim Plus w/Stool & Apron (EXTERIOR VIEW SHOWN) Rev. 3/16/2015 Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-43 INTERIOR TRIM INSTALLATION ACCESSORIES Jamb Extensions Scale 3" = 1' 0" IN T E R IO R JAM B E X T E N S IO N S Accessory Indiv. Box Indiv. Box Part No. No. Part No. No. (Straight) (Straight) (Curved) (Curved) 3/8" Jamb Extension 250R 0654 — — 3/4" Jamb Extension — — 28CU 0BM7 27/32" Jamb Extension 283G 0930 28EA 0BUL 1-1/2" Jamb Extension 301E 0648 30K7 0BUK 2" Jamb Extension with Holes 31J1 — — — 2" Jamb Extension 311M 06EN — — 2-3/8" Jamb Extension 311Q 06EP — — 2-27/32" Jamb Extension 311J 06ER 31A9 0BUJ 3-1/2" Jamb Extension 324A 06ET 32EK 0BUH 3-1/2" Jamb Extension with Holes 3268 0C83 32EL 0BM6 5-1/2" Jamb Extension 30NR 00YX — — Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-44 CUSTOM AZEK® EXTERIOR SURROUND TRIM SHAPES Window Shapes INSTALLATION ACCESSORIES AZEK® exterior composite trim is available for window applications in 1/16" increments provided factory pre-assembled, pre-cut knock-down (when either or both frame height or width > 75") and in lineal (9') lengths for field assembly. Order pre-assembled and pre-cut by actual window frame size. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-45 AZEK® EXTERIOR SURROUND TRIM SHAPES INSTALLATION ACCESSORIES AZEK® exterior composite trim is available for window applications in 1/16" increments provided factory pre-assembled, pre-cut knock-down (when either or both frame height or width > 75") and in lineal (9') lengths for field assembly. Order pre-assembled and pre-cut by actual window frame size. Not all shapes are available on every unit. See your local sales representative for availability. Scale 3" = 1' 0" Description 2" Brickmould AZEK® trim 9 ft 3-3/8" Flat casing AZEK® Trim 9 ft 4-3/8" Flat casing AZEK® Trim 9 ft Sill nose AZEK® Trim 9 ft Crown mould AZEK® Trim 9 ft Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com Part # 0E5B 0E5U 0E5U0001 0E6S 0E5Z W-IA-46 CUSTOM AZEK® EXTERIOR SURROUND TRIM SHAPES Entr y and Patio Door Shapes INSTALLATION ACCESSORIES AZEK® exterior composite trim is available for door applications in 1/16" increments provided factory pre-cut in three knock-down pieces (no sill needed) and in lineal (9’) lengths for field assembly. Order by actual door frame size. Not all shapes are available on every unit. See your local sales representative for availability. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-47 2" AZEK® BRICKMOULD WITH SILL NOSE Installation Details Double-Hung with Brick Veneer INSTALLATION ACCESSORIES Scale 3" = 1' 0" • Refer to the appropriate Pella installation instruction for step by step instructions. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-48 2" AZEK® BRICKMOULD WITH SILL NOSE Installation Details Casement with Stucco INSTALLATION ACCESSORIES Scale 3" = 1' 0" • Refer to the appropriate Pella installation instruction for step by step instructions. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-49 3-3/8" FL AT CASING WITH SILL NOSE AND CROWN Installation Details Double-Hung with Wood Siding INSTALLATION ACCESSORIES Scale 3" = 1' 0" • Refer to the appropriate Pella installation instruction for step by step instructions. Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-50 3-3/8" FL AT CASING WITH SILL NOSE AND CROWN Installation Details Casement with Stucco INSTALLATION ACCESSORIES Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-51 3-3/8" FL AT CASING WITH SILL NOSE AND CROWN Installation Details Double-Hung with Brick Veneer INSTALLATION ACCESSORIES Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-52 INSTALL ATION SYSTEMS Renovation — Exterior Pocket Installation INSTALLATION ACCESSORIES H E AD • • • • • Fully assembled standard double-hung window Slides easily into existing pocket from the exterior Trim, wall coverings, paint and plaster are usually not disturbed Eliminates cost and inconvenience of a complete tear-out Installs from the exterior JAM B S ILL Scale 3" = 1' 0" Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-53 INSTALL ATION SYSTEMS Renovation — Precision Fit® Interior Pocket Installation MAKE HEIGHT 1/4" [6] INSTALLATION ACCESSORIES HEAD MAKE HEIGHT H E AD 1/4" [6] • Fully assembled Precision Fit® double-hung, awning or casement window • Slides easily into existing pocket from the interior • Trim, wall coverings, paint and plaster are usually not disturbed • Eliminates cost and inconvenience of a complete tear-out • Installs from the interior SILL JAM B JAMB 1/4" [6] MAKE WIDTH Scale 3" = 1' 0" S I LL Pella 2016 Architectural Design Manual | Division 08 – Openings | Windows and Doors | www.PellaADM.com W-IA-54