Rheem Residential Air Conditioning
Transcription
Rheem Residential Air Conditioning
Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com INDEX ACCESSORIES...................................................................................................................................................................... 3-6 barb nylon fittings............................................................................................................................................. 3-6 condensor pads..................................................................................................................................................... 3-6 condensor wall bracket................................................................................................................................ 3-7 electricaL................................................................................................................................................................... 3-7 PIPE INSULATION........................................................................................................................................................ 3-7 REFRIGERATION SERVICE TUBING — COPPER................................................................................................ 3-7 COILS — INDOOR — RCFM.......................................................................................................................................... 3-5 CONDENSING UNITS 13AJM- SERIES — 1-1/2 TO 5 TONS...................................................................................................................... 3-3 RANL- JAZ SERIES — 1-1/2 TO 5 TONS................................................................................................................ 3-2 rapm- JAZ SERIES — 1-1/2 TO 5 TONS............................................................................................................... 3-4 TECHNICAL DATA................................................................................................................................................ 3-8 – 3-21 13.0 (IN CERTAIN MATCHED SYSTEMS) 13 SEER MODELS (IN CERTAIN MATCHED SYSTEMS) Available in Northern Alberta, Saskatchewan and Manitoba. ECCO is proud to be a member of: HRAI Heating, Refrigeration and Air Conditioning Institute of Canada www.hrai.ca ECCO Supply HARDI Heating, Air-conditioning & Refrigeration Distributors International www.hardinet.org SMACNA Sheet Metal and Air Conditioning Contractors’ National Association www.smacna.org SPIDA Spiral Duct Manufacturers Association www.spida.org CIPH Canadian Institute of Plumbing & Heating www.ciph.com www.eccosupply.ca 3-1 RANL- *AZ Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 earth friendly refrigerant 13 SEER Models Nominal Sizes 11/2 to 5 Tons [5.28 kW] to [17.6 kW] The Rheem Classic ® Series High Efficiency RANL- Con- densing Units were designed with performance in mind. RHEEM RESIDENTIAL AIR CONDITIONING These units offer comfort, energy conservation and www.rheem.com dependability for single, multi-family and light commercial Cooling Capacities applications. RANLJAZ SERIES 18,300 to 62,000 BTU/HR CONDENSING UNITS — 1-1/2 TO 5 TONS These units also contain the most advanced alternate [5.36 kW] to— [18.17 kW]— 1 phase — 10 YEAR WARRANTY 13 seer R410A refrigerant which contains no chlorofluorocarbons (CFCs), hydrochlorofluorocarbons (HCFCs), or other comThe Rheem Classic® Series High Efficiency RANL- Condensing Unitsor were designed with pounds that may leak from air-conditioning systems and performance in mind. These units offer comfort, energy conservation and dependability for potentially harm the protective ozone layer of the Earth’s single, multi-family and light commercial applications. atmosphere. These units also contain the most advanced alternate refrigerant which contains no The Rheem Classic ® Series RANL- Condensing Units are chlorofluorocarbons (CFCs), or hydrochlorofluorocarbons (HCFCs), the or other resultcompounds of an ongoing development program for improved that may leak from air-conditioning systems and potentially harm the protective ozoneunits are flexible enough to achieve up efficiencies. These layer of the Earth’s atmosphere. to 15.00 SEER in specific match-ups, continuing a tradition high efficiency. The Rheem Classic® Series RANL- Condensing Units are the result ofofan ongoing development program wrap-around for improved efficiencies. These units are flexible enough to achieve Attractive, up to 15.00louvered SEER in specific match-jacket protects the coil from yard hazards and weather extremes. Top grille is ups, continuing a tradition of high efficiency. steel reinforced for extra strength. Cabinet is powder • Attractive, louvered wrap-around jacket protects the • painted All controls are accessible by removing one service for all-weather protection. coil from yard hazards and weather extremes. Top grille panel. Removableupward top grille provides access to theshrubs. Air is discharged away from bushes and is steel reinforced for extra strength. Cabinet is powder condenser fan pattern motor and condenser The discharge of the top grillecoil. provides minimum painted for all-weather protection. restriction. • air Single speed 8-pole fan motor designed for low speed, Combination Grille/Motor Mount the motor to • Air is discharged upward away from bushes and quiet, energy-saving operation. Allsecures models meet or the underside of thesalt discharge grille. grille protects shrubs. The discharge pattern of the top grille provides exceed a 1000-hour spray test per The ASTM B117 the motor Practice windingsfor and bearingsSalt from rainTesting and snow. minimum air restriction. Standard Operating Spray All controls are accessible by removing one service Apparatus. • Combination Grille/Motor Mount secures the motor to panel. Removable top grille provides access to the conthe underside of the discharge grille. The grille protects denser fan motor and condenser coil. the motor windings and bearings from rain and snow. Single speed 8-pole fan motor designed for low speed, quiet, energy-saving operation. Model Number Identification Model Number Identification All models meet or exceed a 1000-hour salt spray test R A N L — 018 J A Practice for Operating Z per ASTM B117 Standard Salt Spray Testing Apparatus. Seven Models RHEEM REMOTE N = 13 SEER CONDENSING UNIT DESIGN SERIES COOLING CAPACITY L = R-410A 13.0 ELECTRICAL DESIGNATION VARIATIONS J = 208/230V-1-60 C = 208/230V-3-60 (RANL MODELS ONLY) D = 460V-3-60 (RANL MODELS ONLY) Y = 575V-3-60 (RANL 4 & 5 TON 13 SEERMODELS MODELS ONLY) 018 = 18,000 BTU/HR [5.28 kW] 024 = 24,000 BTU/HR [7.03 kW] 031 = 30,000 BTU/HR [8.79 kW] 037 = 36,000 BTU/HR [10.55 kW] 043 = 42,000 BTU/HR [12.31 kW] 049 = 48,000 BTU/HR [14.07 kW] 060 = 60,000 BTU/HR [17.58 kW] A-SERIES = FULL-FEATURED (IN CERTAIN MATCHED SYSTEMS) COOLING CONNECTION FITTING Z = SWEAT W/SCROLL [ ] Designates Metric Conversions “Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your local ECCO Sales Representative for details or visit www.energystar.gov” ITEM # Model 885570 885572 885574 885576 885580 885582 RANL-018JAZ RANL-024JAZ RANL-031JAZ RANL-036JAZ RANL-048JAZ RANL-060JAZ COOLING CAPACITY (TONS) ELECTRICAL WEIGHT/ LBS Price 1.5 2.0 2.5 3.0 4.0 5.0 208/230/1 208/230/1 208/230/1 208/230/1 208/230/1 208/230/1 140 150 153 203 214 250 P.O.A. P.O.A. P.O.A. P.O.A. P.O.A. P.O.A. NOTE: 3 Phase units are available — P.O.A. For Technical Data see end of section. – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – 3-2 www.eccosupply.ca ECCO supply Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com 13AjM- SERIES CONDENSING UNITS — 1-1/2 TO 5 TONS 13 seer — R410A — 1 PHASE — 10 YEAR WARRANTY Features • Painted louvered steel cabinet • Easily accessible control box • Condenser coils constructed with copper tubing and enhanced aluminum fins • Grille/Motor mount for quiet fan operation • Bi-Directional Filter Drier (shipped – not installed) Applications Outdoor condensing unit designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light commercial applications. Model Number Identification Model Number Identification 13 A 13 SEER A = AIR CONDITIONER J M VOLTAGE DESIGN SERIES J = 208-230 SINGLE PHASE ITEM # Model 885632 885634 885636 885638 885640 885642 885644 13AJM18A01 13AJM24A01 13AJM30A01 13AJM36A01 13AJM42A01 13AJM48A01 13AJM60A01 18 M = 2ND DESIGN R-410A A 01 NOMINAL COOLING CAPACITY CABINET 18 = 18,000 BTU/HR [5.28 kW] 24 = 24,000 BTU/HR [7.03 kW] 30 = 30,000 BTU/HR [8.79 kW] 36 = 36,000 BTU/HR [10.55 kW] 42 = 42,000 BTU/HR [12.31 kW] 48 = 48,000 BTU/HR [14.07 kW] 60 = 60,000 BTU/HR [17.58 kW] A = FULL METAL JACKET RHEEM VALUE SERIES COOLING CAPACITY (TONS) ELECTRICAL WEIGHT/ LBS Price 1.5 2.0 2.5 3.0 3.5 4.0 5.0 208/230/1 208/230/1 208/230/1 208/230/1 208/230/1 208/230/1 208/230/1 135 135 154 198 195 233 234 P.O.A. P.O.A. P.O.A. P.O.A. P.O.A. P.O.A. P.O.A. Note: For Technical Data see end of section. – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – ECCO supply www.eccosupply.ca 3-3 Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com rapm- JAZ SERIES CONDENSING UNITS — 1-1/2 TO 5 TONS 14 seer — R410A — 1 PHASE — 10 YEAR WARRANTY The Rheem Classic® Series High Efficiency RAPM- Condensing Units were designed with performance in mind. These units offer comfort, energy conservation and dependability for single, multi-family and light commercial applications. These units also contain the most advanced alternate refrigerant which contains no chlorofluorocarbons (CFCs), or hydrochlorofluorocarbons (HCFCs), or other compounds that may leak from air-conditioning systems and potentially harm the protective ozone layer of the Earth’s atmosphere. The Rheem Classic® Series RAPM- Condensing Units are the result of an ongoing development program for improved efficiencies. These units are flexible enough to achieve up to 16.00 SEER in specific match-ups, continuing a tradition of high efficiency. • A ttractive, louvered wrap-around jacket protects the coil from yard hazards and weather extremes. Top grille is steel reinforced for extra strength. Cabinet is powder painted for all-weather protection. • Air is discharged upward away from bushes and shrubs. The discharge pattern of the top grille provides minimum air restriction. • Combination Grille/Motor Mount secures the motor to the underside of the discharge grille. The grille protects the motor windings and bearings from rain and snow. • A ll controls are accessible by removing one service panel. Removable top grille provides access to the condenser fan motor and condenser coil. • Single speed 8-pole fan motor designed for low speed, quiet, energy-saving operation. • All models meet or exceed a 1000-hour salt spray test per ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus. Model Identification ModelNumber Number Identification R RHEEM A P REMOTE P = 14 SEER CONDENSING UNIT M — DESIGN SERIES M = R-410A (2ND DESIGN SERIES) 018 COOLING CAPACITY J ELECTRICAL DESIGNATION 018 = 18,000 BTU/HR [5.28 kW] J = 208/230V-1-60 024 = 24,000 BTU/HR [7.03 kW] 030 = 30,000 BTU/HR [8.79 kW] 036 = 36,000 BTU/HR [10.55 kW] 042 = 42,000 BTU/HR [12.31 kW] 048 = 48,000 BTU/HR [14.07 kW] 060 = 60,000 BTU/HR [17.58 kW] A Z VARIATIONS COOLING CONNECTION FITTING A-SERIES = FULL-FEATURED IN CERTAIN MATCHED SYSTEMS Z = SWEAT W/SCROLL [ ] Designates Metric Conversions “Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your local ECCO Sales Representative for details or visit www.energystar.gov.” ITEM # Model 885480 885482 885484 885486 885488 885490 RAPM-018JAZ RAPM-024JAZ RAPM-030JAZ RAPM-036JAZ RAPM-048JAZ RAPM-060JAZ COOLING CAPACITY (TONS) ELECTRICAL WEIGHT/ LBS Price 1.5 2.0 2.5 3.0 4.0 5.0 208/230/1 208/230/1 208/230/1 208/230/1 208/230/1 208/230/1 152 205 213 223 290 299 P.O.A. P.O.A. P.O.A. P.O.A. P.O.A. P.O.A. Note: Contact your local ECCO Sales Branch for coil pricing. For Technical Data see end of section. – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – 3-4 www.eccosupply.ca ECCO supply Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com RCFM- INDOOR COILS CASED/UNCASED COILS FOR GAS AND OIL FURNACES — R410A AIRFLOW CAPACITIES 600-1,900 CFM [283-897 L/s] Rheem® Indoor Coils are designed for use with Rheem outdoor units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow. When matched with Rheem outdoor units, the coils provide a nominal capacity range from 24,000 BTU/HR [7.03 kW] to 60,000 BTU/HR [17.58 kW]. • Constructed of aluminum fins bonded to internally grooved copper tubing. • C oils are tested at the factory with an extensive refrigerant leak check. Coils have sweat refrigerant connections. • Ideally suited for new installations or add on air conditioning. • Feature two sets of 3/4" [14.1 mm] N.P.T. Condensate drain connections for ease of connection. • Coils are A.R.I. certified for system application with variety of Rheem outdoor units. • Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal-set material. • C ompatible with Germicidal Light System (UV resistant) . • Bi-Directional airflow eliminates the need to switch any internal components from horizontal left to right. • Unique drain pan design maximizes application flexibility and condensate removal. MODEL NUMBER DATA MODEL NUMBER IDENTIFICATION R C F M — HM 24 14 A C Gas/Oil Furnace Coil C = Cased U = Uncased Design Variation A = 1st Design C = 2nd Design Coil Size 17 = 17.5" [431.8 mm] 21 = 21" [533.4 mm] 24 = 24.5" [609.6 mm] Nominal Capacity 24 = 24,000 BTU/HR [7.03 kW] 36 = 36,000 BTU/HR [10.55 kW] 48 = 48,000 BTU/HR [14.06 kW] 60 = 60,000 BTU/HR [17.58 kW] Available Models of RCFM Coils RCFM-HM2417AC RCFM-HU2417AU RCFM-HM2421AC RCFM-HU2421AU RCFM-HM3617AC RCFM-HU3617AU RCFM-HM3617CC RCFM-HU3617CU RCFM-HM3621AC RCFM-HU3621AU RCFM-HM3621CC RCFM-HM4821AC RCFM-HM4824AC RCFM-HM6024AC RCFM-HU3621CU RCFM-HU4821AU RCFM-HU4824AU RCFM-HU6024AU Cased Coil Airflow: HM = A/C or Heat Pump, Multi-Position Uncased Coil Airflow: HU = A/C or Heat Pump, Upflow/Downflow Refrigerant M = R-410A (16 SEER) F = Product Generation Classification C = Coil Rheem Note: For Technical Data see end of section. – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – ECCO supply www.eccosupply.ca 3-5 Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com ACCESSORIES ITEM # Model DESCRIPTION 709720 709821 709722 709724 709726 709817 709820 709804 709805 709809 709807 709808 709810 709813 BC-CB151TUL BC-CB151UL BC-CB151LSUL CP-22 CP-22T VCMA-15ULST VCMA-15UL 3/8" × 1/2" 3/8" × 1/2" × 100' 3/4" × 1" × 100' 1/2" × 5/8" × 100' 1/2" × 5/8" 5/8" × 3/4" 5/8" × 3/4" × 100' Condensate Pump with Switch and Tubing Condensate Pump Condensate Pump Condensate Pump Condensate Pump w/Tubing Condensate Pump Condensate Pump Clear Plastic Tubing Clear Plastic Tubing Clear Plastic Tubing Clear Plastic Tubing Clear Plastic Tubing Clear Plastic Tubing Clear Plastic Tubing Price $155.00 149.00 138.00 109.00 106.00 149.00 130.00 .64/ft 44.00/roll 139.00/roll 56.00/roll .85/ft .75/ft 70.00/roll condensor pads ITEM # Model SIZE (") DESCRIPTION 709700 709706 709710 709712 709714 709715 709716 709717 — UltraLite UltraLite UltraLite UltraLite UltraLite E-Lite E-Lite 24 × 30 16 × 36 × 2 24 × 30 × 2 32 × 32 × 2 36 × 36 × 2 40 × 40 × 2 32 × 32 × 2 36 × 36 × 2 Cement Patio Block Concrete Pad Concrete Pad Concrete Pad Concrete Pad Concrete Pad Plastic Pad Plastic Pad Price $30.00 50.00 53.00 79.00 99.00 117.00 89.00 107.00 barb nylon fittings ITEM # Model DESCRIPTION Price 709815 709814 709816 709812 709811 — — — — TEA-2416 3/4" MIP × 5/8" Barb 90° Elbow 3/4" MPT × 3/4" Barb 90° Elbow 3/4" FIP × 5/8" Barb 90° Elbow 3/4" MPT × 3/4" Barb Adapter 3/4" MPT × 1/2" Barb Adapter $3.10 3.10 3.10 2.00 2.00 – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – 3-6 www.eccosupply.ca ECCO supply Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com ACCESSORIES (cont’d) electricaL ITEM # Model DESCRIPTION 888000 887990 DDS-60U B6-12-6NM Air Conditioner Disconnect A/C Electrical Whip Price $47.33 30.49 PIPE INSULATION ITEM # DESCRIPTION Price 709229 709230 709231 709233 709235 709236 709237 5/8" × 3/8" × 6 ft. Generic 7/8" × 3/8" × 6 ft. Generic 3/4" × 3/8" × 6 ft. Generic 1-1/8" × 3/8" × 6 ft. Generic 3/4" × 3/8" × 6 ft. Armaflex 7/8" × 3/8" × 6 ft. Armaflex 1-1/8" × 3/8" × 6 ft. Armaflex $6.20 8.88 8.88 11.06 8.88 8.88 11.06 Pipe Insulation REFRIGERATION SERVICE TUBING — COPPER ITEM # DESCRIPTION C709000 709220 709221 709222 709223 709224 709225 709226 709227 WALL THICKNESS 1/8" × 50 ft. 1/4" × 50 ft. 5/16" × 50 ft. 3/8" × 50 ft. 1/2" × 50 ft. 5/8" × 50 ft. 3/4" × 50 ft. 7/8" × 50 ft. 1-1/8" × 50 ft. .030 .030 .032 .032 .032 .032 .035 .035 .050 Price/ROll P.O.A. $86.00 92.00 140.00 175.00 240.00 305.00 465.00 695.00 Copper Tubing condensor wall bracket ITEM # SIZE 599740 599730 599736 599742 599738 30 18 × 30 18 × 36 18 × 38 18 × 42 WALL THICKNESS Condensor Wall Bracket (MB & ON only) Condensor Bracket 1-1/2 – 3 Ton Condensor Bracket 3 – 5 Ton Condensor Wall Bracket Condensor Wall Bracket with Cross Brace Price/PAIR $87.35 112.32 127.53 100.98 335.38 Not exactly as illustrated. – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – ECCO supply www.eccosupply.ca 3-7 Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com TECHNICAL DATA RANL*AZ*AZ RANL- FORM NO. A11-184 REV. 8 Supersedes Form No. A11-184 Rev. 7 13 SEER Models Nominal Sizes 11/2 to 5 Tons [5.28 kW] to [17.6 kW] CONDENSING UNITS earth friendly refrigerant Seven Models Cooling Capacities 18,300 to 62,000 BTU/HR [5.36 kW] to [18.17 kW] FORM NO. A11-184 REV. 8 Supersedes Form No. A11-184 Rev. 7 Engineering Features RANL- Series Condensing Units RANL- *AZ earth friendly refrigerant 13 SEER Models Nominal Sizes 11/2 to 5 Tons [5.28 kW] to [17.6 kW] Seven Models Cooling Capacities 18,300 to 62,000 BTU/HR [5.36 kW] to [18.17 kW] All controls and compressor are accessible for servicing by removal of the service panel. Combination Grille/Motor Mount secures the motor to the underside of the discharge grille. The grille protects the motor windings and bearings from rain and snow. All controls are accessible by removing one service panel. Removable top grille provides access to the condenser fan motor and condenser coil. Single speed 8-pole fan motor designed for low speed, quiet, energy-saving operation. All models meet or exceed a 1000-hour salt spray test (cont’dSalt on next page) per ASTM B117 Standard Practice for Operating Spray Testing Apparatus. Drawn Painted Base Pan. Model Number Identification R A RHEEM N REMOTE N = 13 SEER CONDENSING UNIT L DESIGN SERIES — 13.0 1. This unit contains a special scroll compressor that is designed specifically to operate with R-410A refrigerants and polyolester (POE) oils. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise. 2. Compressors have an internal pressure relief assembly to protect against excessive pressure differential. The Rheem Classic ® Series High Efficiency RANL- Con3. All refrigerant connections are on the exterior of the unit, densing Units were designed with performance in mind. located the ground for neat appearing installations. These units close offer to comfort, energy conservation and dependability single, multi-family and light commercial 4. Cabinet for is constructed of powder painted galvanized applications. steel. The full wraparound louvered grille protects the coil These units also contain the most advanced alternate from damage. refrigerant which contains no chlorofluorocarbons (CFCs), 5. Copper tube—aluminum fin coils are used on all models. or hydrochlorofluorocarbons (HCFCs), or other com6. Thethat control located in the top systems corner ofand the cabinet pounds may box leak is from air-conditioning potentially harmfor theeasy protective ozone layeraofservice the Earth’s providing access through panel. atmosphere. 7. Service valves are standard on all models. The Rheem Classic ® Series RANL- Condensing Units are 8. result Power and control wiring are program kept separate. the of an ongoing development for improved efficiencies. These arecharged flexible enough to achieve up 9. Every unit is units factory and tested. to 15.00 SEER in specific match-ups, continuing a tradition 10.high Separate compressor compartment for easy service access. of efficiency. 11. Drawn,louvered painted wrap-around base pan forjacket extraprotects corrosion and Attractive, the resistance coil from yard reduction. hazards and weather extremes. Top grille is sound steel reinforced for extra strength. Cabinet is powder 12. Automatic reset high and low pressure controls are standard painted for all-weather protection. on all models. Air is discharged upward away from bushes and shrubs. 13. liquid linepattern filter drier standard on all models TheAdischarge of theistop grille provides minimum(shipped – not installed). air restriction. 018 COOLING CAPACITY J ELECTRICAL DESIGNATION A Z VARIATIONS COOLING CONNECTION FITTING A-SERIES = FULL-FEATURED 018 = 18,000 BTU/HR [5.28 kW] J = 208/230V-1-60 Z = SWEAT W/SCROLL C = 208/230V-3-60 024 = 24,000 BTU/HR [7.03 kW] 13 SEER MODELS (RANL MODELS 031 = 30,000 BTU/HR [8.79 kW] MATCHED (IN CERTAIN SYSTEMS) ONLY) 037 = 36,000 BTU/HR [10.55 kW] “Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps D = 460V-3-60 043 = 42,000 BTU/HR [12.31 kW] must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your local ECCO Sales Representative for details (RANL MODELS 049 = 48,000 BTU/HR [14.07 kW] or visit www.energystar.gov” ONLY) 060 = 60,000 BTU/HR [17.58 kW] Y = 575V-3-60 – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All4 Taxes Extra – May not be Available at All Branches – (RANL & 5 TON [ ] Designates Metric Conversions MODELS ONLY) 3-8 www.eccosupply.ca L = R-410A ECCO supply Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com TECHNICAL DATA (cont’d) RANL- *AZ (cont‘d) Electrical and Physical Data: RANLELECTRICAL Model No. RANL- Phase Frequency (Hz) Voltage (Volts) 018JAZ 024JAZ 031JAZ 037CAZ 037DAZ 037JAZ 043CAZ 043DAZ 043JAZ 049CAZ 049DAZ 049JAZ 049YAZ 060CAZ 060DAZ 060JAZ 060YAZ 1-60-208/230 1-60-208/230 1-60-208/230 3-60-208/230 3-60-460 1-60-208/230 3-60-208/230 3-60-460 1-60-208/230 3-60-208/230 3-60-460 1-60-208/230 3-60-575 3-60-208/230 3-60-460 1-60-208/230 3-60-575 PHYSICAL Compressor Outdoor Coil Fan Fuse or HACR Motor Min. Circuit Circuit Breaker Rated Locked Full Load Ampacity Load Rotor Face Area No. Amperes Amperes Amperes Amperes Sq. Ft. [m2] Rows Min. Max. (FLA) (RLA) (LRA) Amperes Amperes 9/9 12.8/12.8 14.1/14.1 13.2/13.2 6 17.9/17.9 13.6/13.6 6.1 19.9/19.9 13.7/13.7 6.2 21.8/21.8 4.8 15.6/15.6 7.8 26.3/26.3 5.8 48 58.3 73 88 44 112 83.1 41 109 83.1 41 117 33 110 52 134 38.9 [ ] Designates Metric Conversions 0.6 0.6 0.6 1.2 0.6 1.2 1.2 0.6 1.2 1.2 0.6 1.2 0.5 1.2 0.6 1.2 0.5 12/12 17/17 19/19 18/18 9 24/24 19/19 9 27/27 19/19 9 29/29 7 21/21 11 35/35 8 15/15 20/20 25/25 25/25 15 30/30 25/25 15 35/35 25/25 15 35/35 15 25/25 15 45/45 15 20/20 25/25 30/30 30/30 15 40/40 30/30 15 45/45 30/30 15 50/50 15 35/35 15 60/60 15 9.07 [0.84] 11.00 [1.02] 11.06 [1.03] 16.10 [1.50] 16.10 [1.50] 16.10 [1.50] 16.10 [1.50] 16.10 [1.50] 16.10 [1.50] 20.13 [1.87] 23.13 [2.15] 20.13 [1.87] 20.13 [1.87] 23.01 [2.14] 23.01 [2.14] 23.01 [2.14] 23.01 [2.14] 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CFM [L/s] 1775 [838] 1920 [906] 1920 [906] 3200 [1510] 3200 [1510] 3200 [1510] 3200 [1510] 3200 [1510] 3200 [1510] 3500 [1652] 3500 [1652] 3500 [1652] 3500 [1652] 3500 [1652] 3500 [1652] 3500 [1652] 3500 [1652] Weight Refrig. Per Circuit Oz. [g] Net Lbs. [kg] Shipping Lbs. [kg] 70 [1984] 72 [2041] 83 [2353] 106 [3005] 106 [3005] 106 [3005] 115 [3260] 115 [3260] 115 [3260] 132 [3742] 132 [3742] 132 [3742] 132 [3742] 180 [5103] 180 [5103] 180 [5103] 180 [5103] 130 [59.0] 140 [63.5] 143 [64.9] 193 [87.5] 193 [87.5] 193 [87.5] 202 [91.6] 202 [91.6] 202 [91.6] 214 [97.1] 214 [97.1] 214 [97.1] 214 [97.1] 250 [113.4] 250 [113.4] 250 [113.4] 250 [113.4] 140 [63.5] 150 [68.0] 153 [69.4] 203 [92.1] 203 [92.1] 203 [92.1] 212 [96.2] 212 [96.2] 212 [96.2] 224 [101.6] 224 [101.6] 224 [101.6] 224 [101.6] 260 [117.9] 260 [117.9] 260 [117.9] 260 [117.9] (cont’d on next page) – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – ECCO supply www.eccosupply.ca 3-9 Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com TECHNICAL DATA (cont’d) RANL- *AZ (cont‘d) Unit Dimensions AIR DISCHARGE ALLOW 60 [1524 mm] CLEARANCE LOW VOLTAGE CONNECTION 7/80 [22 mm] W SERVICE FITTINGS L HIGH VOLTAGE CONNECTION 111/320 [34 mm] ACCESS PANEL H 003 A-00 AIR INLETS (LOUVERS) ALLOW 6 [152 mm] MIN. CLEARANCE 3 SIDES A-00 001 VAPOR LINE CONNECTION HIGH PRESSURE CONTROL MANUAL RESET (FIELD INSTALLED ACCESSORY) ALLOW 24 [610 mm] ACCESS CLEARANCE LIQUID LINE CONNECTION SERVICE ACCESS TO ELECTRICAL & 27/80 [73 mm] DIA. VALVES ALLOW ACCESSORY 240 [610 mm] KNOCKOUTS CLEARANCE ONE SIDE Model Number RANL018 Height “H” (Inches) [mm] 19 [483] Length “L” (Inches) [mm] 351/2 [902] Width “W” (Inches) [mm] 233/4 [603] 024/031 19 [483] 401/2 [1029] 275/8 [702] 037/043 23 [584] 443/8 [1127] 311/2 [800] 049 060 29 [737] 33 [838] 443/8 [1127] 443/8 [1127] 311/2 [800] 311/2 [800] [ ] Designates Metric Conversions (cont’d on next page) BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. Condenser Coil leaks caused by factory defects ........................................Five (5) Years Compressor— JAZ ......................................................Ten (10) Years CAZ, DAZ, YAZ..............................................Five (5) Years *All Other Parts JAZ ................................................................Five (5) Years CAZ, DAZ, YAZ ........................................One (1) Year *This five year limited warranty is applicable only to single-phase products installed in residential applications on or after January 1, 2001. – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – 3-10 www.eccosupply.ca ECCO supply Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com TECHNICAL DATA (cont’d) RANL- *AZ (cont‘d) Condensing Unit Refrigerant Line Size Information Liquid Line Sizing (R-410A) Liquid Line Size – Outdoor Unit Above Indoor Coil Liquid Line Size – Outdoor Unit Below Indoor Coil (Cooling Only – Does not apply to Heat Pumps) Line Size Line Size Total Equivalent Length—Feet [m] Total Equivalent Length—Feet [m] System Connection (Inch O.D.) Capacity 25 50 75 100 125 150 25 50 75 100 125 150 (Inch I.D.) [mm] [7.62] [15.24] [22.86] [30.48] [38.10] [45.72] [7.62] [15.24] [22.86] [30.48] [38.10] [45.72] Minimum Vertical Separation—Feet [m] Maximum Vertical Separation—Feet [m] 1/4* [6.35] 0 0 0 0 8 [2.44] 24 [7.32] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74] N/A N/A 3/8″ 11/2 Ton 5/16 [7.94] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14.94] 3/8* [9.53] 1/4* [6.35] 0 0 3/8″ 5/16 [7.94] 0 21/2 Ton 3/8″ 3/8* [9.53] 1/4* [6.35] 5/16 [7.94] 0 0 0 3 Ton 3/8″ 3/8* [9.53] 5/16* [7.94] 3/8* [9.53] 0 0 0 0 0 0 0 0 0 31/2 Ton 3/8″ 5/16* [7.94] 0 0 0 4 Ton 3/8″ 5 Ton 3/8″ 3/8* [9.53] 3/8* [9.53] 1/2 [12.57] 3/8* [9.53] 1/2 [12.57] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 Ton 0 0 0 0 0 25 [7.62] 50 [15.24] 75 [22.86] 72 [21.95] 70 [21.34] 68 [20.73] 3 [0.91] 29 [8.84] 55 [16.76] 81 [24.69] 108 [32.92] 23 [7.01] N/A N/A N/A N/A N/A 0 0 0 0 0 0 14 [4.27] 56 [17.07] 98 [29.87] 0 0 0 0 0 0 0 0 25 [7.62] 36 [10.97] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74] 0 N/A 0 0 N/A 0 25 [7.62] 50 [15.24] 72 [21.95] 70 [21.34] 68 [20.73] 65 [19.81] 25 [7.62] N/A N/A N/A N/A N/A 25 [7.62] 49 [14.94] 38 [11.58] 27 [8.23] 17 [5.18] 6 [1.83] 0 0 0 0 25 [7.62] 50 [15.24] 68 [20.73] 65 [19.81] 62 [18.90] 58 [17.68] 9 [2.74] 25 [7.62] 50 [15.24] 37 [11.28] 22 [6.71] 7 [2.13] N/A 0 25 [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15] 16 [4.88] 35 [10.67] 54 [16.46] 25 [7.62] 23 [7.01] 4 [1.22] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 25 [7.62] 25 [7.62] 25 [7.62] 25 [7.62] 25 [7.62] 50 [15.24] 46 [14.02] 50 [15.24] 50 [15.24] 50 [15.24] 43 [13.11] 38 [11.58] 56 [17.07] 56 [17.07] 75 [22.86] N/A N/A 36 [10.97] 30 [9.14] 55 [16.76] 44 [13.41] 81 [24.69] N/A 30 [9.14] 24 [7.32] 22 [6.71] 15 [4.57] 53 [16.15] 52 [15.85] 32 [9.75] 20 [6.10] 79 [24.08] 76 [23.16] NOTES: *Standard line size N/A = Application not recommended. Suction Line Length/Size versus Capacity Multiplier (R-410A) Unit Size 11/2 Ton Suction Line Connection Size Suction Line Run— Feet [m] Optional Standard Optional Optional 50' [15.24] Standard Optional Optional 100' [30.48] Standard Optional Optional 150' [45.72] Standard Optional 25' [7.62] 2 Ton 3/4" 1.00 1.00 N/A .98 .99 N/A .95 .96 N/A .92 .94 N/A 3 Ton [19.05 mm] I.D. 5/8" [15.88 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Std.* 1.00 1.00 N/A .98 .99 N/A .95 .96 N/A .92 .93 N/A 21/2 Ton 5/8" [15.88 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Std.* 7/8" [22.23 mm] O.D. Opt. 1.00 1.00 1.00 .96 .98 .99 .94 .96 .97 .91 .93 .95 7/8" 1.00 1.00 N/A .98 .99 N/A .96 .97 N/A .94 .95 N/A 1.00 1.00 N/A .99 .99 N/A .96 .98 N/A .94 .96 N/A 4 Ton 5 Ton [22.23 mm] I.D. 3/4" [19.05 mm] O.D. Opt. 7/8" [22.23 mm] O.D. Std.* NOTES: *Standard line size Using suction line larger than shown in chart will result in poor oil return and is not recommended. Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. 31/2 Ton 7/8" [22.23 mm] O.D. Opt. 11/8" [28.58 mm] O.D. Std.* 1.00 1.00 N/A .99 .99 N/A .96 .98 N/A .95 .96 N/A 1.00 1.00 N/A .99 .99 N/A .97 .98 N/A .94 .97 N/A [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating P.O. Box 17010, Fort Smith, AR 72917 “In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without no tice.” PRINTED IN U.S.A. 11-08 DC FORM NO. A11-184 REV. 8 Supersedes Form No. A11-184 Rev. 7 – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – ECCO supply www.eccosupply.ca 3-11 Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com TECHNICAL DATA 13AJM- SERIES FORM NO. A11-202 REV. 1 Supersedes Form No. A11-202 Electrical and Physical Data ELECTRICAL PHYSICAL Fuse or HACR Compressor Model Fan Motor Minimum Refrigerant Outdoor Coil Phase Circuit Breaker Number Full Load Circuit Per Rated Load Locked Rotor Frequency [HZ] 13AJM Amperes Ampacity Minimum Maximum Face Area No. Circuit Amperes Voltage [Volts] Amperes CFM [L/s] (FLA) Amperes Amperes Amperes Sq. Ft. [m2] Rows Oz. [g] (RLA) (LRA) Rev. 7/29/09 Weight Net Lbs. [kg] Shipping Lbs. [kg] 18 1-60-208/230 9/9 48 0.6 12/12 15/15 20/20 8.43 [0.78] 1 1675 [790] 75.2 [2132] 120 [54.4] 128 [58.1] 24 1-60-208/230 13.5/13.5 58.3 0.6 18/18 25/25 30/30 8.43 [0.78] 1 1665 [786] 73.8 [2092] 121 [54.9] 129 [58.5] 30 36 1-60-208/230 1-60-208/230 12.8/12.8 16.7/16.7 73 79 0.6 0.8 17/17 22/22 20/20 30/30 25/25 35/35 10.29 [0.96] 12.43 [1.15] 1 1 2075 [979] 86.8 [2440] 139 [63.1] 147 [66.7] 2805 [1324] 96 [2722] 159 [72.1] 167 [75.8] 42 1-60-208/230 17.9/17.9 112 0.8 24/24 30/30 40/40 16.39 [1.52] 1 3295 [1555] 126.4 [3583] 188 [85.3] 192 [87.1] 48 60 1-60-208/230 1-60-208/230 21.8/21.8 26.4/26.4 117 134 0.8 1.2 29/29 35/35 35/35 45/45 45/45 60/60 21.85 [2.03] 21.85 [2.03] 1 1 3295 [1555] 144 [4082] 207 [93.9] 218 [98.9] 3570 [1685] 176 [4990] 223 [101.2] 234 [106.1] NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set. Unit Dimensions Model No. 13AJL 18, 24 30 36, 42 48, 60 Unit Dimensions Width “W” Inches Length “L” Inches Height “H” Inches 235/8 [600] 275/8 [702] 315/8 [803] 315/8 [803] 235/8 [600] 275/8 [702] 315/8 [803] 315/8 [803] 241/4 [616] 241/4 [616] 2715/16 [710] 3515/16 [913] [ ] Designates Metric Conversions w detail a LOW VOLTAge 7/8" [22 mm] HOLE DIAMETER HIGH VOLTAge 1-11/32" [34 mm] HOLE DIAMETER L SERVICE FITTING H SERVICE FITTING 2" [50.8 mm] SEE DETAIL A BASERAIL LIQUID line connection vapor line connection (cont’d on next page) 13.0 – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – 3-12 www.eccosupply.ca ECCO supply Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com TECHNICAL DATA (cont’d) 13AJM- SERIES (cont’d) Condensing Unit Refrigerant Line Size Information Liquid Line Sizing (R-410A) Liquid Line Size – Outdoor Unit Above Indoor Coil Liquid Line Size – Outdoor Unit Below Indoor Coil (Cooling Only—Does not apply to Heat Pumps) Liquid Line Line Size Total Equivalent Length—Feet [m] Total Equivalent Length—Feet [m] System Connection (Inch O.D.) Size Capacity 25 50 75 100 125 150 25 50 75 100 125 150 [mm] (Inch I.D.) [7.62] [15.24] [22.86] [30.48] [38.10] [45.72] [7.62] [15.24] [22.86] [30.48] [38.10] [45.72] Minimum Vertical Separation—Feet [m] Maximum Vertical Separation—Feet [m] 1/4 [6.35] 0 0 0 0 8 [2.44] 24 [7.32] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74] N/A N/A ″ 3/8 11/2 Ton 5/16* [7.94] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14.94] [9.53] 3/8* [9.53] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 75 [22.86] 72 [21.95] 70 [21.34] 68 [20.73] 1/4 [6.35] 0 3 [0.91] 29 [8.84] 55 [16.76] 81 [24.69] 108 [32.92] 23 [7.01] N/A N/A N/A N/A N/A ″ 3/8 2 Ton 5/16* [7.94] 0 0 0 0 0 0 25 [7.62] 36 [10.97] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74] [9.53] 21/2 Ton 3/8″ [9.53] 3 Ton 3/8″ [9.53] 31/2 Ton 3/8″ [9.53] 4 Ton 3/8″ [9.53] 5 Ton 3/8″ [9.53] 3/8* [9.53] 1/4 [6.35] 5/16* [7.94] 3/8* [9.53] 5/16 [7.94] 0 0 0 0 0 0 0 0 14 [4.27] 56 [17.07] 98 [29.87] 0 0 0 0 0 0 0 0 0 0 0 N/A 0 0 0 0 25 [7.62] N/A 25 [7.62] 0 25 [7.62] 0 25 [7.62] 9 [2.74] 25 [7.62] 0 0 50 [15.24] N/A 49 [14.94] 50 [15.24] 50 [15.24] 72 [21.95] N/A 38 [11.58] 68 [20.73] 37 [11.28] 70 [21.34] 68 [20.73] 65 [19.81] N/A N/A N/A 27 [8.23] 17 [5.18] 6 [1.83] 65 [19.81] 62 [18.90] 58 [17.68] 22 [6.71] 7 [2.13] N/A 3/8* [9.53] 0 0 0 5/16 [7.94] 0 0 0 25 [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15] 3/8* [9.53] 3/8* [9.53] 1/2 [12.57] 3/8* [9.53] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 25 [7.62] 25 [7.62] 25 [7.62] 25 [7.62] 1/2 [12.57] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 75 [22.86] 81 [24.69] 79 [24.08] 76 [23.16] 16 [4.88] 35 [10.67] 54 [16.46] 25 [7.62] 23 [7.01] 4 [1.22] 50 [15.24] 46 [14.02] 50 [15.24] 50 [15.24] 43 [13.11] 38 [11.58] 56 [17.07] 56 [17.07] N/A N/A N/A 36 [10.97] 30 [9.14] 24 [7.32] 30 [9.14] 22 [6.71] 15 [4.57] 55 [16.76] 53 [16.15] 52 [15.85] 44 [13.41] 32 [9.75] 20 [6.10] NOTES: *Standard line size N/A = Application not recommended. Unit Size Suction Line Connection Size Suction Line Run—Feet [m] 25' [7.62] 50' [15.24] 100' [30.48] 150' [45.72] Optional Standard Optional Optional Standard Optional Optional Standard Optional Optional Standard Optional 11/2 Ton Suction Line Length/Size versus Capacity Multiplier (R-410A) 2 Ton 21/2 Ton 3 Ton 3/4" [19.05] I.D. 5/8" [15.88 mm] O.D. Optional 3/4" [19.05 mm] O.D. Standard* 1.00 1.00 — .98 .99 — .95 .96 — .92 .93 — 5/8" [15.88 mm] O.D. Optional 3/4" [19.05 mm] O.D. Standard* 7/8" [22.23 mm] O.D. Optional 1.00 1.00 — .98 .99 — .95 .96 — .92 .94 — 1.00 1.00 1.00 .96 .98 .99 .94 .96 .97 .91 .93 .95 31/2 Ton 4 Ton 7/8" [22.23] I.D. 3/4" [19.05 mm] O.D. Optional 7/8" [22.23 mm] O.D. Standard* 1.00 1.00 — .98 .99 — .96 .97 — .94 .95 — 1.00 1.00 — .99 .99 — .96 .98 — .94 .96 — 5 Ton 7/8" [22.23 mm] O.D. Optional 11/8" [28.58 mm] O.D. Standard* 1.00 1.00 — .99 .99 — .96 .98 — .95 .96 — 1.00 1.00 — .99 .99 — .97 .98 — .94 .97 — NOTES: *Standard line size Using suction line larger than shown in chart will result in poor oil return and is not recommended. [ ] Designates Metric Conversions BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or visit www.Rheem.com. Condenser Coil leaks caused by factory defects ........................................Five (5) Years Conditional Compressor* ............................Ten (10) Years Any Other Part............................................Five (5) Years *See Product Warranty Card for Details. – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Heating, Taxes Extra – Mayand notWater be Available – Rheem Cooling Heatingat All Branches 5 ECCO supply www.eccosupply.ca 3-13 Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com technical data (cont’d) RAPMJAZ RAPMJAZ 14.5 SEER Models Efficiencies up to 16.00 SEER Nominal Sizes 11/2 to 5 Tons [5.28 kW] to [17.6 kW] Seven Models Cooling Capacities 18,600 to 62,500 BTU/HR [5.45 kW] to [18.32 kW] FORM NO. A11-199 REV. 1 Supersedes Form No. A11-199 Engineering Features RAPM- Series Condensing Units All controls and compressor are accessible for servicing by removal of the service panel. 1. This unit contains a special scroll compressor that is designed specifically to operate with R-410A refrigerants and polyolester (POE) oils. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise. 2. Compressors have an internal pressure relief assembly to protect against excessive pressure differential. 3. All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations. 4. Cabinet is constructed of powder painted galvanized steel. The full wraparound louvered grille protects the coil from damage. 5. Copper tube—aluminum fin coils are used on all models. 6. The control box is located in the top corner of the cabinet providing for easy access through a service panel. 7. Service valves are standard on all models. 8. Power and control wiring are kept separate. 9. Every unit is factory charged and tested. 10. Separate compressor compartment for easy service access. 11. Drawn, painted base pan for extra corrosion resistance and sound reduction. 12. Automatic reset high and low pressure controls are standard on all models. 13. A liquid line filter drier is standard on all models (shipped – not installed). Drawn Painted Base Pan. (cont’d on next page) IN CERTAIN MATCHED SYSTEMS “Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your local ECCO Sales Representative for details or visit www.energystar.gov.” – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – 3-14 www.eccosupply.ca ECCO supply Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com technical data (cont’d) RAPM- JAZ (cont’d) Electrical and Physical Data: RAPMELECTRICAL Compressor Model Fan Motor Phase Number Rated Load Locked Rotor Full Load Frequency (Hz) RAPMAmperes Amperes Voltage (Volts) Amperes (FLA) (RLA) (LRA) Rev. 11/18/09 018JAZ 1-60-208/230 024JAZ 1-60-208/230 030JAZ 1-60-208/230 9/9 13.5/13.5 12.8/12.8 PHYSICAL Fuse or HACR Minimum Refrig. Outdoor Coil Circuit Breaker Circuit Per Ampacity Minimum Maximum Face Area No. Circuit CFM [L/s] Amperes Amperes Amperes Sq. Ft. [m2] Rows Oz. [g] Weight Net Lbs. [kg] Shipping Lbs. [kg] 48 58.3 64 1.9 1.1 1.9 14/14 18/18 18/18 20/20 25/25 25/25 20/20 30/30 30/30 11.00 [1.02] 20.00 [1.86] 20.00 [1.86] 1 1 1 2300 [1085] 82 [2325] 138.5 [62.8] 160.5 [72.8] 3300 [1557] 128 [3629] 192.5 [87.3] 214.5 [97.3] 3300 [1557] 129 [3657] 193 [87.5] 214 [97.1] 036JAZ 1-60-208/230 16/16 79 1.9 22/22 30/30 35/35 23.01 [2.14] 1 3300 [1557] 146 [4139] 197.5 [89.6] 227 042JAZ 1-60-208/230 048JAZ 1-60-208/230 060JAZ 1-60-208/230 17.9/17.9 21.8/21.8 26.4/26.4 112 117 134 2.8 2.8 2.8 26/26 31/31 36/36 30/30 40/40 45/45 40/40 50/50 60/60 23.01 [2.14] 23.01 [2.14] 23.00 [2.14] 1 2 2 3300 [1557] 152 [4309] 223 [101.2] 256 [116.1] 3300 [1557] 203 [5755] 264 [119.8] 298 [135.2] 3300 [1557] 262 [7428] 269.5 [122.2] 306.5 [139] [103] Unit Dimensions AIR DISCHARGE ALLOW 60 [1524 mm] CLEARANCE LOW VOLTAGE CONNECTION 7/80 [22 mm] W SERVICE FITTINGS L HIGH VOLTAGE CONNECTION 111/320 [34 mm] ACCESS PANEL H 003 A-00 AIR INLETS (LOUVERS) ALLOW 6 [152 mm] MIN. CLEARANCE 3 SIDES ALLOW 24 [610 mm] ACCESS CLEARANCE 001 A-00 Model Number RAPM018 Height “H” (Inches) [mm] 19 [483] Length “L” (Inches) [mm] 401/2 [1029] Width “W” (Inches) [mm] 275/8 [702] 024/030 29 [737] 443/8 [1127] 311/2 [800] 036/042/ 048/060 33 [838] 443/8 [1127] 311/2 [800] VAPOR LINE CONNECTION HIGH PRESSURE CONTROL MANUAL RESET (FIELD INSTALLED ACCESSORY) LIQUID LINE CONNECTION SERVICE ACCESS TO ELECTRICAL & 27/80 [73 mm] DIA. VALVES ALLOW ACCESSORY 240 [610 mm] KNOCKOUTS CLEARANCE ONE SIDE [ ] Designates Metric Conversions (cont’d on next page) BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. Condenser Coil leaks caused by factory defects ........................................Five (5) Years Compressor— JAZ ......................................................Ten (10) Years Conditional Parts* (Registration Required) ................................Ten (10) Years *This five year limited warranty is applicable only to single-phase products installed Notice in residential afternot January 1, 2001. at All Branches – – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without – All applications Taxes Extraon– or May be Available ECCO supply 20 Rheem Heating, Cooling and Water Heating www.eccosupply.ca 3-15 Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com technical data (cont’d) RAPM- JAZ (cont’d) Condensing Unit Refrigerant Line Size Information Liquid Line Sizing (R-410A) Liquid Line Size – Outdoor Unit Above Indoor Coil Liquid Line Size – Outdoor Unit Below Indoor Coil (Cooling Only – Does not apply to Heat Pumps) Line Size Line Size Total Equivalent Length—Feet [m] Total Equivalent Length—Feet [m] System Connection (Inch O.D.) Capacity 25 50 75 100 125 150 25 50 75 100 125 150 (Inch I.D.) [mm] [7.62] [15.24] [22.86] [30.48] [38.10] [45.72] [7.62] [15.24] [22.86] [30.48] [38.10] [45.72] Minimum Vertical Separation—Feet [m] Maximum Vertical Separation—Feet [m] 1/4* [6.35] 0 0 0 0 8 [2.44] 24 [7.32] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74] N/A N/A 3/8″ 11/2 Ton 5/16 [7.94] 0 0 0 0 0 0 25 [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14.94] 2 Ton 21/2 Ton 3/8* [9.53] 1/4* [6.35] 0 0 3/8″ 5/16 [7.94] 0 3/8″ 3/8* [9.53] 1/4* [6.35] 5/16 [7.94] 0 0 0 3/8* [9.53] 5/16* [7.94] 3/8* [9.53] 0 0 0 0 0 0 0 0 0 5/16* [7.94] 0 0 0 3/8* [9.53] 3/8* [9.53] 1/2 [12.57] 3/8* [9.53] 1/2 [12.57] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 Ton 3/8″ 31/2 Ton 3/8″ 4 Ton 3/8″ 5 Ton 3/8″ 0 0 0 0 0 25 [7.62] 50 [15.24] 75 [22.86] 72 [21.95] 70 [21.34] 68 [20.73] 3 [0.91] 29 [8.84] 55 [16.76] 81 [24.69] 108 [32.92] 23 [7.01] N/A N/A N/A N/A N/A 0 0 0 0 0 0 14 [4.27] 56 [17.07] 98 [29.87] 0 0 0 0 0 0 0 0 25 [7.62] 36 [10.97] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74] 0 N/A 0 0 N/A 0 25 [7.62] 50 [15.24] 72 [21.95] 70 [21.34] 68 [20.73] 65 [19.81] 25 [7.62] N/A N/A N/A N/A N/A 25 [7.62] 49 [14.94] 38 [11.58] 27 [8.23] 17 [5.18] 6 [1.83] 0 0 0 0 25 [7.62] 50 [15.24] 68 [20.73] 65 [19.81] 62 [18.90] 58 [17.68] 9 [2.74] 25 [7.62] 50 [15.24] 37 [11.28] 22 [6.71] 7 [2.13] N/A 0 25 [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15] 16 [4.88] 35 [10.67] 54 [16.46] 25 [7.62] 23 [7.01] 4 [1.22] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 25 [7.62] 25 [7.62] 25 [7.62] 25 [7.62] 25 [7.62] 50 [15.24] 46 [14.02] 50 [15.24] 50 [15.24] 50 [15.24] 43 [13.11] 38 [11.58] 56 [17.07] 56 [17.07] 75 [22.86] N/A 36 [10.97] 30 [9.14] 55 [16.76] 44 [13.41] 81 [24.69] N/A N/A 30 [9.14] 24 [7.32] 22 [6.71] 15 [4.57] 53 [16.15] 52 [15.85] 32 [9.75] 20 [6.10] 79 [24.08] 76 [23.16] NOTES: *Standard line size N/A = Application not recommended. Suction Line Length/Size versus Capacity Multiplier (R-410A) Unit Size 11/2 Ton Suction Line Connection Size Suction Line Run— Feet [m] 25' [7.62] Optional Standard Optional Optional 50' [15.24] Standard Optional Optional 100' [30.48] Standard Optional Optional 150' [45.72] Standard Optional 2 Ton 3/4" 1.00 1.00 N/A .98 .99 N/A .95 .96 N/A .92 .94 N/A 3 Ton [19.05 mm] I.D. 5/8" [15.88 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Std.* 1.00 1.00 N/A .98 .99 N/A .95 .96 N/A .92 .93 N/A 21/2 Ton 5/8" 3/4" 7/8" [15.88 mm] O.D. Opt. [19.05 mm] O.D. Std.* [22.23 mm] O.D. Opt. 1.00 1.00 1.00 .96 .98 .99 .94 .96 .97 .91 .93 .95 31/2 Ton 7/8" 1.00 1.00 N/A .99 .99 N/A .96 .98 N/A .94 .96 N/A 5 Ton [22.23 mm] I.D. 3/4" [19.05 mm] O.D. Opt. 7/8" [22.23 mm] O.D. Std.* 1.00 1.00 N/A .98 .99 N/A .96 .97 N/A .94 .95 N/A 4 Ton 7/8" [22.23 mm] O.D. Opt. 11/8" [28.58 mm] O.D. Std.* 1.00 1.00 N/A .99 .99 N/A .96 .98 N/A .95 .96 N/A 1.00 1.00 N/A .99 .99 N/A .97 .98 N/A .94 .97 N/A NOTES: *Standard line size [ ] Designates Metric Conversions Using suction line larger than shown in chart will result in poor oil return and is not recommended. – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – 3-16 www.eccosupply.ca ECCO supply [14.06 kW] 60 = 60,000 BTU/HR [17.58 kW] Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 Cased Coil Airflow: HM = A/C or Heat Pump, Multi-Position Uncased Coil Airflow: HU = A/C or Heat Pump, Upflow/Downflow Refrigerant M = R-410A (16 SEER) RHEEM RESIDENTIAL AIR CONDITIONING F = Product Generation www.rheem.com Classification C = Coil technical data (cont’d) Rheem INDOOR COILS — RCFM- FORM NO. C11-212 REV. 3 Supersedes Form No. C11-212 Rev. 2 Table 1: Coil Specifications/Airflow Pressure Drop Coil Model Number Approx. Design Air Flow CFM [L/s] Range Face Area Sq. Ft. [m2] Fins-in. Rows Deep Static Pressure Drop Through Wet Cooling Coil [kPa] (Inches W.C.) CFM [L/s] 600 [283] 700 [330] 800 [378] 900 [425] 1000 [472] 1100 [519] .12 [.029] .10 [.025] .17 [.042] .15 [.037] .17 [.042] .15 [.037] .21 [.052] .18 [.045] .21 [.052] .18 [.045] .26 [.065] .23 [.057] .31 [.077] .27 [.067] 1200 [566] 1300 [614] 1400 [661] 1500 [708] 1600 [756] 1700 [802] 1800 [850] 1900 [897] — — — — — — — — — — — — — — — — .36 [.09] .31 [.077] .22 [.055] .22 [.055] .41 [.102] .37 [.092] .25 [.062] .25 [.062] .17 [.042] — — — — — — — — — — — — .28 [.07] .28 [.07] .20 [.05] .32 [.08] .32 [.08] .024 [.058] .36 [.09] .36 [.09] .27 [.067] .41 [.102] .41 [.102] .30 [.075] — — HIGH EFFICIENCY COOLING COILS 600/800 [283/376] 600/800 [283/376] 900/1200 [424/566] 900/1200 [424/566] 1200/1600 [566/755] 1200/1600 [566/755] 1300/1700 [614/802] 2417 2421 3617 3621 4821 4824 6024 5.70 [0.53] 5.70 [0.53] 5.70 [0.53] 5.70 [0.53] 8.55 [0.79] 8.55 [0.79] 9.98 [0.93] .07 [.017] .05 [.014] 16/2 16/2 16/2 — — 16/2 — — 16/2 — — — — — — 16/2 — — — — — — 14/3 — — — — — — — — — .34 [.085] .37 [.092] NOTE: Represents Coil-Only Airflow Ratings [ ] Designates Metric Conversions Table 2: Coil Dimensions and Weights Coil Model Number 2 Connections Sweat (in.) [mm] Liquid I.D. 2417 3/8 2421 3/8 3617 Cased Coil Dimensions (in) [mm] Suction I.D. C Coil Weight (lbs.) [Kg.] Shipping Weight (lbs.) [Kg.] [454] 20 [508] 52 [24] 57 [26] 171/2 [445] 20 [508] 52 [24] 60 [27] 171/2 [445] 20 [508] 52 [24] 57 [26] 21 1/2[533] 171/2 [445] 20 [508] 54 [24] 60 [27] 21 1/2[533] 257/8 [657] 28 [711] 76 [34] 83 [38] 241/2 [622] Heating 241/2 [622] 253/8 [645] 301/4 [768] 32 [812] 32 [812] 89 [40] 108 [49] 99 [45] 118 [54] A [9.53] 3/4 [19.05] 171/2 [9.53] 3/4 [19.05] 21 1/2[533] 3/8 [9.53] 3/4 [19.05] 171/2 [445] 3621 3/8 [9.53] 3/4 [19.05] 4821 3/8 [9.53] 7/8 [22.23] 4824 Rheem 6024 3/8 [9.53] 3/8 [9.53] Heating, Cooling 7/8 [22.23] 7/8 [22.23] and Water Weight [445] B 177/8 (cont’d on next page) FIGURE 1: DIMENSIONS A MINUS ONE INCH PLENUM WIDTH 197/8 [505 mm] – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – FRONT VIEW ECCO supply www.eccosupply.ca 3-17 NOTE: FLANGES ARE PROVIDED Table 2: Coil Dimensions and Weights Coil Model Number Connections Sweat (in.) [mm] Liquid I.D. Cased Coil Dimensions (in) [mm] Suction I.D. Weight Pricing Effective: June 2011 Shipping Weight Coil Weight Revised: June 2011 • Replaces: October 2006 (lbs.) [Kg.] (lbs.) [Kg.] A B C 20 [508] 20 [508] 52 [24] 57 [26] 52 [24] 60 [27] 2417 2421 3/8 [9.53] 3/4 [19.05] 171/2 [445] 177/8 [454] 3/8 [9.53] 3/4 [19.05] 21 1/2[533] 171/2 [445] 3617 3/8 [9.53] 3/4 [19.05] 171/2 [445] 3621 4821 3/8 [9.53] 3/8 [9.53] 3/4 [19.05] 7/8 [22.23] 21 1/2[533] 21 1/2[533] 257/8 [657] 28 [711] 76 [34] 83 [38] 4824 6024 3/8 7/8 241/2 [622] 241/2 [622] 253/8 [645] 301/4 [768] 32 [812] 32 [812] 89 [40] 108 [49] 99 [45] 118 [54] [9.53] 3/8 [9.53] 17 / [445] 20 [508] 52 [24] 57 [26] RHEEM RESIDENTIAL AIR CONDITIONING 17 / [445] 20 [508] 54 [24] 60 [27] [22.23] 7/8 [22.23] technical data (cont’d) 12 12 www.rheem.com INDOOR COILS — RCFM- (cont’d) FIGURE 1: DIMENSIONS A MINUS ONE INCH 197/8 [505 mm] PLENUM WIDTH FRONT VIEW SIDE VIEW 1/2 NOTE: FLANGES ARE PROVIDED FOR FIELD INSTALLATION [12.7 mm] 17/16 [36.5 mm] SUCTION LINE 7/16 [11.1 mm] LIQUID LINE 515/16 [150.8 mm] 53/8 [136.5 mm] PRIMARY DRAIN 3/4 N.P.T. (VERTICAL & HORIZONTAL) 113/16 [46 mm] 11/4 [31.7 mm] 41/8 [104.7 mm] 2111/16 [550.8 mm] 21/4 [57.1 mm] SECONDARY DRAIN 3/4 N.P.T. (VERTICAL) [ ] Designates Metric Conversions PRIMARY DRAIN 3/4 N.P.T. (VERTICAL) Casing top and bottom openings are the same dimensions. (cont’d on next page) Rheem Heating, Cooling and Water Heating 3 – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – 3-18 www.eccosupply.ca ECCO supply Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com technical data (cont’d) INDOOR COILS — RCFM- (cont’d) Table 3: Coil Application Coils can be matched to heating products as listed in table below. Furnace Width (In.) (mm) Coil Model Oil* 2417 3617 Gas — 14 2417 3617 21 [533] 2421 3621 4821 21 [533] 4824 6024 [356] 171/2 [444] 14 [356] 21 [533] 171/2 [444] 241/2 [622] 21 [533] 241/2 [622] *Note: Due to the proximity of the drain pan to the high temperature oil furnace drum, horizontal left application is NOT permitted on all oil furnaces. Accessories • PLENUM ADAPTER ACCESSORY RXBA-AE This plenum adapter accessory is for use with the 24 1/2" wide cased indoor cooling and heat pump coils. This allows a 241/2" wide cased coil to be installed on a 28" wide oil furnace. This is a field-installed accessory only. • RXBA-AC (Upflow/Horizontal) These plenum adapter accessories are for use when a cooling coil is matched with a gas furnace of one smaller size. • HORIZONTAL ADAPTER KIT RXHH (See Figure 2) This horizontal adapter kit is used to convert a upflow or downflow coil for a horizontal application. See Table 4 to order the proper horizontal adapter kit. • INDOOR COIL CASING- RXBC (See Table 5) R X B C — D 17 I INSULATION I = Insulated Blank = Uninsulated CABINET WIDTH 17 = 17.5" [444 mm] 21 = 21" [533 mm] 24 = 24.5" [622 mm] DESIGN SERIES COIL CASING BLOWER UNIT ACCESSORY RHEEM [ ] Designates Metric Conversions (cont’d on next page) – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – ECCO supply www.eccosupply.ca 3-19 Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com technical data (cont’d) INDOOR COILS — RCFM- (cont’d) Accessories (cont’d) Table 4: Horizontal Adapter Kit Model No. Coil Model 2417/3617/3621 4821/4824 6024 Horizontal Adapter Kit Model No. RXHH-A03 RXHH-A04 RXHH-A05 FIGURE 2: HORIZONTAL ADAPTER KIT ILLUSTRATION Table 5: Unit Dimensions and Weights- RXBC Indoor Coil Casings Model Number Depth Width Height (in.) (in.) [mm] (in.) [mm] [mm] Supply Air/Return Air Openings Unit Weight Weight Ship. Wt. Width (lbs.) [Kg.] (lbs.) [Kg.] (in.) [mm] Depth (in.) [mm] RXBC-D17AI 171/2 [445] 20 [508] 18 [8] 23 [10] 161/2 [419] RXBC-D21AI 21 [533] 20 [508] 215/8 RXBC-D21BI 21 [533] 28 [711] [549] RXBC-D24AI 241/2 [622] 321/2 [826] 20 [9] 27 [12] 34 [16] 26 [12] 36 [17] 44 [20] 20 [508] 1931/32 20 [508] [508] 231/2 [597] • TXV REPLACEMENT KITS – RXCT AIR FLOW HORIZONTAL-DUAL DIRECTION Coil Model RC*M-H*24* RC*M-H*36* RC*M-H*48* RC*M-H*60* R-410A TXV Kit RXCT-FBA RXCT-FBB RXCT-FBD RXCT-FBE Obsolete Kit Part No. 611020 611021 611023 None NOTE: Valve can be R-22 or R-410A if date code is M2308 or later. • TXV CONVERSION KITS – RXCT HORIZONTAL ADAPTER KIT (RXHH-) Coil Model RC*A-H*36* RC*A-H*36* RC*A-H*48* RC*A-H*60* R-22 to R-410A TXV Kit RXCT-FBA RXCT-FBB RXCT-FBD RXCT-FBE Makes Coil RC*M-H*24* RC*M-H*36* RC*M-H*48* RC*M-H*60* Coil Model RC*M-H*24* RC*M-H*36* RC*M-H*48* RC*M-H*60* R-410A to R-22 TXV Kit RXCT-EBB RXCT-EBB RXCT-EBC RXCT-EBD Makes Coil RC*A-H*36* RC*A-H*36* RC*A-H*48* RC*A-H*60* NOTE: Valve can be R-22 or R-410A if date code is M2308 or later. [ ] Designates Metric Conversions (cont’d on next page) – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – 3-20 www.eccosupply.ca ECCO supply Pricing Effective: June 2011 Revised: June 2011 • Replaces: October 2006 RHEEM RESIDENTIAL AIR CONDITIONING www.rheem.com technical data (cont’d) INDOOR COILS — RCFM- (cont’d) Accessories (cont’d) • UNCASED COIL ADAPTER KIT RXBA- (See Figure 3 & 4) This uncased coil adapter kit is used to adapt the coil to a furnace or ductwork. See Table 6 to order the proper adapter kit. Each kit contains a quantity of 20 adapters. FIGURE 3: UNCASED COIL ADAPTER KIT ILLUSTRATION Table 6: Uncased Coil Adapter Kit Uncased Coil Adapter Model Number RXBA A Width (in.) [mm] Uncased Coil Model RCFA/L B14x20 B17x20 131/8 [333] 165/8 [422] -HUxx14 -HUxx17 B21x20 B24x20 201/8 [511] 235/8 [599] -HUxx21 -HUxx24 [ ] Designates Metric Conversions 11/2 [41 mm] 711/16 [196 mm] A 205/16 [516 mm] FIGURE 4: UNCASED COIL ADAPTER KIT ASSEMBLED Note: Sliding the coil into the coil rail before attaching coil rack front. – E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches – ECCO supply www.eccosupply.ca 3-21
Similar documents
Rheem Classic® Series Upflow/Horizontal Gas Furnace
For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, direct spark ignition is 100% safety lockout type.
More information