ACCESSORIES...................................................................................................................................................................... 3-6
barb nylon fittings............................................................................................................................................. 3-6
condensor pads..................................................................................................................................................... 3-6
condensor wall bracket................................................................................................................................ 3-7
electricaL................................................................................................................................................................... 3-7
PIPE INSULATION........................................................................................................................................................ 3-7
REFRIGERATION SERVICE TUBING — COPPER................................................................................................ 3-7
COILS — INDOOR — RCFM.......................................................................................................................................... 3-5
CONDENSING UNITS
13AJM- SERIES — 1-1/2 TO 5 TONS...................................................................................................................... 3-3
RANL- JAZ SERIES — 1-1/2 TO 5 TONS................................................................................................................ 3-2
rapm- JAZ SERIES — 1-1/2 TO 5 TONS............................................................................................................... 3-4
TECHNICAL DATA................................................................................................................................................ 3-8 – 3-21
13.0
(IN CERTAIN
MATCHED
SYSTEMS)
13 SEER
MODELS
(IN CERTAIN MATCHED SYSTEMS)
Available in Northern Alberta, Saskatchewan and Manitoba.
ECCO is proud to be a member of:
HRAI
Heating, Refrigeration and
Air Conditioning
Institute of Canada
www.hrai.ca
ECCO Supply
HARDI
Heating, Air-conditioning
& Refrigeration
Distributors International
www.hardinet.org
SMACNA
Sheet Metal and Air
Conditioning Contractors’
National Association
www.smacna.org
SPIDA
Spiral Duct
Manufacturers
Association
www.spida.org
CIPH
Canadian Institute
of Plumbing &
Heating
www.ciph.com
www.eccosupply.ca 3-1
RANL- *AZ
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
earth friendly refrigerant
13 SEER Models
Nominal Sizes 11/2 to 5 Tons
[5.28 kW] to [17.6 kW]
The Rheem Classic ® Series High Efficiency RANL- Con-
densing Units were designed
with performance in mind.
RHEEM RESIDENTIAL
AIR CONDITIONING
These units offer comfort, energy conservation
and
www.rheem.com
dependability for single, multi-family and light commercial
Cooling Capacities
applications.
RANLJAZ SERIES
18,300
to 62,000
BTU/HR CONDENSING UNITS — 1-1/2 TO 5 TONS
These units also contain the most advanced alternate
[5.36
kW] to—
[18.17
kW]— 1 phase — 10 YEAR WARRANTY
13 seer
R410A
refrigerant which contains no chlorofluorocarbons (CFCs),
hydrochlorofluorocarbons
(HCFCs), or other comThe Rheem Classic® Series High Efficiency RANL- Condensing Unitsor
were
designed with
pounds
that
may
leak
from
air-conditioning
systems and
performance in mind. These units offer comfort, energy conservation and dependability for
potentially harm the protective ozone layer of the Earth’s
single, multi-family and light commercial applications.
atmosphere.
These units also contain the most advanced alternate refrigerant which
contains no
The Rheem Classic ® Series RANL- Condensing Units are
chlorofluorocarbons (CFCs), or hydrochlorofluorocarbons (HCFCs), the
or other
resultcompounds
of an ongoing development program for improved
that may leak from air-conditioning systems and potentially harm the
protective
ozoneunits are flexible enough to achieve up
efficiencies.
These
layer of the Earth’s atmosphere.
to 15.00 SEER in specific match-ups, continuing a tradition
high
efficiency.
The Rheem Classic® Series RANL- Condensing Units are the result ofofan
ongoing
development program
wrap-around
for improved efficiencies. These units are flexible enough to achieve Attractive,
up to 15.00louvered
SEER in specific
match-jacket protects the coil
from yard hazards and weather extremes. Top grille is
ups, continuing a tradition of high efficiency.
steel reinforced for extra strength. Cabinet is powder
• Attractive, louvered wrap-around jacket protects the
• painted
All controls
are accessible
by removing one service
for all-weather
protection.
coil from yard hazards and weather extremes. Top grille
panel.
Removableupward
top grille
provides
access to
theshrubs.
Air
is discharged
away
from bushes
and
is steel reinforced for extra strength. Cabinet is powder
condenser
fan pattern
motor and
condenser
The
discharge
of the
top grillecoil.
provides minimum
painted for all-weather protection.
restriction.
• air
Single
speed 8-pole fan motor designed for low speed,
Combination
Grille/Motor
Mount
the motor
to
• Air is discharged upward away from bushes and
quiet, energy-saving
operation.
Allsecures
models meet
or
the
underside
of thesalt
discharge
grille.
grille
protects
shrubs. The discharge pattern of the top grille provides
exceed
a 1000-hour
spray test
per The
ASTM
B117
the
motor Practice
windingsfor
and
bearingsSalt
from
rainTesting
and snow.
minimum air restriction.
Standard
Operating
Spray
All
controls
are
accessible
by
removing
one service
Apparatus.
• Combination Grille/Motor Mount secures the motor to
panel. Removable top grille provides access to the conthe underside of the discharge grille. The grille protects
denser fan motor and condenser coil.
the motor windings and bearings from rain and snow.
Single speed 8-pole fan motor designed for low speed,
quiet,
energy-saving operation.
Model Number
Identification
Model
Number
Identification
All models meet or exceed a 1000-hour salt spray test
R
A
N
L
—
018
J
A Practice for Operating
Z
per ASTM
B117 Standard
Salt
Spray Testing Apparatus.
Seven Models
RHEEM
REMOTE
N = 13 SEER
CONDENSING
UNIT
DESIGN
SERIES
COOLING
CAPACITY
L = R-410A
13.0
ELECTRICAL
DESIGNATION
VARIATIONS
J = 208/230V-1-60
C = 208/230V-3-60
(RANL MODELS
ONLY)
D = 460V-3-60
(RANL MODELS
ONLY)
Y = 575V-3-60
(RANL 4 & 5 TON
13 SEERMODELS
MODELS
ONLY)
018 = 18,000 BTU/HR [5.28 kW]
024 = 24,000 BTU/HR [7.03 kW]
031 = 30,000 BTU/HR [8.79 kW]
037 = 36,000 BTU/HR [10.55 kW]
043 = 42,000 BTU/HR [12.31 kW]
049 = 48,000 BTU/HR [14.07 kW]
060 = 60,000 BTU/HR [17.58 kW]
A-SERIES = FULL-FEATURED
(IN CERTAIN MATCHED SYSTEMS)
COOLING CONNECTION
FITTING
Z = SWEAT W/SCROLL
[ ] Designates Metric Conversions
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps
must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your local ECCO Sales Representative for details
or visit www.energystar.gov”
ITEM #
Model
885570
885572
885574
885576
885580
885582
RANL-018JAZ
RANL-024JAZ
RANL-031JAZ
RANL-036JAZ
RANL-048JAZ
RANL-060JAZ
COOLING
CAPACITY
(TONS)
ELECTRICAL
WEIGHT/
LBS
Price
1.5
2.0
2.5
3.0
4.0
5.0
208/230/1
208/230/1
208/230/1
208/230/1
208/230/1
208/230/1
140
150
153
203
214
250
P.O.A.
P.O.A.
P.O.A.
P.O.A.
P.O.A.
P.O.A.
NOTE: 3 Phase units are available — P.O.A.
For Technical Data see end of section.
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
3-2 www.eccosupply.ca
ECCO supply
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
13AjM- SERIES CONDENSING UNITS — 1-1/2 TO 5 TONS
13 seer — R410A — 1 PHASE — 10 YEAR WARRANTY
Features
• Painted louvered steel cabinet
• Easily accessible control box
• Condenser coils constructed with copper tubing and enhanced aluminum fins
• Grille/Motor mount for quiet fan operation
• Bi-Directional Filter Drier (shipped – not installed)
Applications
Outdoor condensing unit designed for ground level or rooftop installations. These units offer comfort
and dependability for single, multi-family and light commercial applications.
Model Number Identification
Model
Number Identification
13
A
13 SEER
A = AIR CONDITIONER
J
M
VOLTAGE
DESIGN
SERIES
J = 208-230
SINGLE PHASE
ITEM #
Model
885632
885634
885636
885638
885640
885642
885644
13AJM18A01
13AJM24A01
13AJM30A01
13AJM36A01
13AJM42A01
13AJM48A01
13AJM60A01
18
M = 2ND
DESIGN R-410A
A
01
NOMINAL COOLING CAPACITY
CABINET
18 = 18,000 BTU/HR [5.28 kW]
24 = 24,000 BTU/HR [7.03 kW]
30 = 30,000 BTU/HR [8.79 kW]
36 = 36,000 BTU/HR [10.55 kW]
42 = 42,000 BTU/HR [12.31 kW]
48 = 48,000 BTU/HR [14.07 kW]
60 = 60,000 BTU/HR [17.58 kW]
A = FULL METAL JACKET
RHEEM
VALUE
SERIES
COOLING
CAPACITY
(TONS)
ELECTRICAL
WEIGHT/
LBS
Price
1.5
2.0
2.5
3.0
3.5
4.0
5.0
208/230/1
208/230/1
208/230/1
208/230/1
208/230/1
208/230/1
208/230/1
135
135
154
198
195
233
234
P.O.A.
P.O.A.
P.O.A.
P.O.A.
P.O.A.
P.O.A.
P.O.A.
Note: For Technical Data see end of section.
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
ECCO supply
www.eccosupply.ca 3-3
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
rapm- JAZ SERIES CONDENSING UNITS — 1-1/2 TO 5 TONS
14 seer — R410A — 1 PHASE — 10 YEAR WARRANTY
The Rheem Classic® Series High Efficiency RAPM- Condensing Units were designed with
performance in mind. These units offer comfort, energy conservation and dependability
for single, multi-family and light commercial applications.
These units also contain the most advanced alternate refrigerant which contains no
chlorofluorocarbons (CFCs), or hydrochlorofluorocarbons (HCFCs), or other compounds
that may leak from air-conditioning systems and potentially harm the protective ozone
layer of the Earth’s atmosphere.
The Rheem Classic® Series RAPM- Condensing Units are the result of an ongoing
development program for improved efficiencies. These units are flexible enough to
achieve up to 16.00 SEER in specific match-ups, continuing a tradition of high efficiency.
• A
ttractive, louvered wrap-around jacket protects the coil
from yard hazards and
weather extremes. Top grille is steel reinforced for extra
strength. Cabinet is powder painted for all-weather
protection.
• Air is discharged upward away from bushes and
shrubs. The discharge pattern of the top grille provides
minimum air restriction.
• Combination Grille/Motor Mount secures the motor to
the underside of the discharge grille. The grille protects
the motor windings and bearings from rain and snow.
• A
ll controls are accessible by removing one service
panel. Removable top grille provides access to the
condenser fan motor and condenser coil.
• Single speed 8-pole fan motor designed for low speed,
quiet, energy-saving operation.
• All models meet or exceed a 1000-hour salt spray test
per ASTM B117 Standard Practice for Operating Salt
Spray Testing Apparatus.
Model
Identification
ModelNumber
Number
Identification
R
RHEEM
A
P
REMOTE
P = 14 SEER
CONDENSING
UNIT
M
—
DESIGN
SERIES
M = R-410A
(2ND DESIGN
SERIES)
018
COOLING
CAPACITY
J
ELECTRICAL
DESIGNATION
018 = 18,000 BTU/HR [5.28 kW] J = 208/230V-1-60
024 = 24,000 BTU/HR [7.03 kW]
030 = 30,000 BTU/HR [8.79 kW]
036 = 36,000 BTU/HR [10.55 kW]
042 = 42,000 BTU/HR [12.31 kW]
048 = 48,000 BTU/HR [14.07 kW]
060 = 60,000 BTU/HR [17.58 kW]
A
Z
VARIATIONS
COOLING CONNECTION
FITTING
A-SERIES = FULL-FEATURED
IN CERTAIN MATCHED SYSTEMS
Z = SWEAT W/SCROLL
[ ] Designates Metric Conversions
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be
matched with appropriate coil components to meet ENERGY STAR criteria. Ask your local ECCO Sales Representative for details or
visit www.energystar.gov.”
ITEM #
Model
885480
885482
885484
885486
885488
885490
RAPM-018JAZ
RAPM-024JAZ
RAPM-030JAZ
RAPM-036JAZ
RAPM-048JAZ
RAPM-060JAZ
COOLING
CAPACITY
(TONS)
ELECTRICAL
WEIGHT/
LBS
Price
1.5
2.0
2.5
3.0
4.0
5.0
208/230/1
208/230/1
208/230/1
208/230/1
208/230/1
208/230/1
152
205
213
223
290
299
P.O.A.
P.O.A.
P.O.A.
P.O.A.
P.O.A.
P.O.A.
Note: Contact your local ECCO Sales Branch for coil pricing.
For Technical Data see end of section.
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
3-4 www.eccosupply.ca
ECCO supply
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
RCFM- INDOOR COILS
CASED/UNCASED COILS FOR GAS AND OIL FURNACES — R410A
AIRFLOW CAPACITIES
600-1,900 CFM [283-897 L/s]
Rheem® Indoor Coils are designed for use with Rheem outdoor units and are available
for vertical upflow or downflow, and horizontal left or horizontal right airflow. When
matched with Rheem outdoor units, the coils provide a nominal capacity range from
24,000 BTU/HR [7.03 kW] to 60,000 BTU/HR [17.58 kW].
• Constructed of aluminum fins bonded to internally grooved copper tubing. • C
oils are tested at the factory with an extensive
refrigerant leak check. Coils have sweat refrigerant
connections.
• Ideally suited for new installations or add on air
conditioning.
• Feature two sets of 3/4" [14.1 mm] N.P.T. Condensate
drain connections for ease of connection.
• Coils are A.R.I. certified for system application with
variety of Rheem outdoor units.
• Condensate drain pan is constructed of high grade, heat
resistant, corrosion free thermal-set material.
• C
ompatible with Germicidal Light System (UV resistant) .
• Bi-Directional airflow eliminates the need to switch any
internal components from horizontal left to right.
• Unique drain pan design maximizes application
flexibility and condensate removal.
MODEL
NUMBER
DATA
MODEL
NUMBER
IDENTIFICATION
R
C
F
M
— HM 24 14
A
C
Gas/Oil Furnace Coil
C = Cased
U = Uncased
Design Variation
A = 1st Design
C = 2nd Design
Coil Size
17 = 17.5" [431.8 mm]
21 = 21" [533.4 mm]
24 = 24.5" [609.6 mm]
Nominal Capacity
24 = 24,000 BTU/HR
[7.03 kW]
36 = 36,000 BTU/HR
[10.55 kW]
48 = 48,000 BTU/HR
[14.06 kW]
60 = 60,000 BTU/HR
[17.58 kW]
Available Models of RCFM Coils
RCFM-HM2417AC
RCFM-HU2417AU
RCFM-HM2421AC
RCFM-HU2421AU
RCFM-HM3617AC
RCFM-HU3617AU
RCFM-HM3617CC
RCFM-HU3617CU
RCFM-HM3621AC
RCFM-HU3621AU
RCFM-HM3621CC
RCFM-HM4821AC
RCFM-HM4824AC
RCFM-HM6024AC
RCFM-HU3621CU
RCFM-HU4821AU
RCFM-HU4824AU
RCFM-HU6024AU
Cased Coil Airflow:
HM = A/C or Heat Pump, Multi-Position
Uncased Coil Airflow:
HU = A/C or Heat Pump, Upflow/Downflow
Refrigerant
M = R-410A (16 SEER)
F = Product Generation
Classification
C = Coil
Rheem
Note: For Technical Data see end of section.
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
ECCO supply
www.eccosupply.ca 3-5
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
ACCESSORIES
ITEM #
Model
DESCRIPTION
709720
709821
709722
709724
709726
709817
709820
709804
709805
709809
709807
709808
709810
709813
BC-CB151TUL
BC-CB151UL
BC-CB151LSUL
CP-22
CP-22T
VCMA-15ULST
VCMA-15UL
3/8" × 1/2"
3/8" × 1/2" × 100'
3/4" × 1" × 100'
1/2" × 5/8" × 100'
1/2" × 5/8"
5/8" × 3/4"
5/8" × 3/4" × 100'
Condensate Pump with Switch and Tubing
Condensate Pump
Condensate Pump
Condensate Pump
Condensate Pump w/Tubing
Condensate Pump
Condensate Pump
Clear Plastic Tubing
Clear Plastic Tubing
Clear Plastic Tubing
Clear Plastic Tubing
Clear Plastic Tubing
Clear Plastic Tubing
Clear Plastic Tubing
Price
$155.00
149.00
138.00
109.00
106.00
149.00
130.00
.64/ft
44.00/roll
139.00/roll
56.00/roll
.85/ft
.75/ft
70.00/roll
condensor pads
ITEM #
Model
SIZE (")
DESCRIPTION
709700
709706
709710
709712
709714
709715
709716
709717
—
UltraLite
UltraLite
UltraLite
UltraLite
UltraLite
E-Lite
E-Lite
24 × 30
16 × 36 × 2
24 × 30 × 2
32 × 32 × 2
36 × 36 × 2
40 × 40 × 2
32 × 32 × 2
36 × 36 × 2
Cement Patio Block
Concrete Pad
Concrete Pad
Concrete Pad
Concrete Pad
Concrete Pad
Plastic Pad
Plastic Pad
Price
$30.00
50.00
53.00
79.00
99.00
117.00
89.00
107.00
barb nylon fittings
ITEM #
Model
DESCRIPTION
Price
709815
709814
709816
709812
709811
—
—
—
—
TEA-2416
3/4" MIP × 5/8" Barb 90° Elbow
3/4" MPT × 3/4" Barb 90° Elbow
3/4" FIP × 5/8" Barb 90° Elbow
3/4" MPT × 3/4" Barb Adapter
3/4" MPT × 1/2" Barb Adapter
$3.10
3.10
3.10
2.00
2.00
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
3-6 www.eccosupply.ca
ECCO supply
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
ACCESSORIES (cont’d)
electricaL
ITEM #
Model
DESCRIPTION
888000
887990
DDS-60U
B6-12-6NM
Air Conditioner Disconnect
A/C Electrical Whip
Price
$47.33
30.49
PIPE INSULATION
ITEM #
DESCRIPTION
Price
709229
709230
709231
709233
709235
709236
709237
5/8" × 3/8" × 6 ft. Generic
7/8" × 3/8" × 6 ft. Generic
3/4" × 3/8" × 6 ft. Generic
1-1/8" × 3/8" × 6 ft. Generic
3/4" × 3/8" × 6 ft. Armaflex
7/8" × 3/8" × 6 ft. Armaflex
1-1/8" × 3/8" × 6 ft. Armaflex
$6.20
8.88
8.88
11.06
8.88
8.88
11.06
Pipe Insulation
REFRIGERATION SERVICE TUBING — COPPER
ITEM #
DESCRIPTION
C709000
709220
709221
709222
709223
709224
709225
709226
709227
WALL THICKNESS
1/8" × 50 ft.
1/4" × 50 ft.
5/16" × 50 ft.
3/8" × 50 ft.
1/2" × 50 ft.
5/8" × 50 ft.
3/4" × 50 ft.
7/8" × 50 ft.
1-1/8" × 50 ft.
.030
.030
.032
.032
.032
.032
.035
.035
.050
Price/ROll
P.O.A.
$86.00
92.00
140.00
175.00
240.00
305.00
465.00
695.00
Copper Tubing
condensor wall bracket
ITEM #
SIZE
599740
599730
599736
599742
599738
30
18 × 30
18 × 36
18 × 38
18 × 42
WALL THICKNESS
Condensor Wall Bracket (MB & ON only)
Condensor Bracket 1-1/2 – 3 Ton
Condensor Bracket 3 – 5 Ton
Condensor Wall Bracket
Condensor Wall Bracket with Cross Brace
Price/PAIR
$87.35
112.32
127.53
100.98
335.38
Not exactly as
illustrated.
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
ECCO supply
www.eccosupply.ca 3-7
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
TECHNICAL DATA
RANL*AZ*AZ
RANL-
FORM NO. A11-184 REV. 8
Supersedes Form No. A11-184 Rev. 7
13 SEER Models
Nominal Sizes 11/2 to 5 Tons
[5.28 kW] to [17.6 kW]
CONDENSING UNITS
earth friendly refrigerant
Seven Models
Cooling Capacities
18,300 to 62,000 BTU/HR
[5.36 kW] to [18.17 kW]
FORM NO. A11-184 REV. 8
Supersedes Form No. A11-184 Rev. 7
Engineering Features
RANL- Series Condensing Units
RANL- *AZ
earth friendly refrigerant
13 SEER Models
Nominal Sizes 11/2 to 5 Tons
[5.28 kW] to [17.6 kW]
Seven Models
Cooling Capacities
18,300 to 62,000 BTU/HR
[5.36 kW] to [18.17 kW]
All controls and compressor are accessible
for servicing by removal of the service panel.
Combination Grille/Motor Mount secures the motor to
the underside of the discharge grille. The grille protects
the motor windings and bearings from rain and snow.
All controls are accessible by removing one service
panel. Removable top grille provides access to the condenser fan motor and condenser coil.
Single speed 8-pole fan motor designed for low speed,
quiet, energy-saving operation.
All models meet or exceed a 1000-hour salt spray test
(cont’dSalt
on next page)
per ASTM B117 Standard Practice for Operating
Spray Testing Apparatus.
Drawn Painted Base Pan.
Model Number Identification
R
A
RHEEM
N
REMOTE
N = 13 SEER
CONDENSING
UNIT
L
DESIGN
SERIES
—
13.0
1. This unit contains a special scroll compressor that is
designed specifically to operate with R-410A refrigerants
and polyolester (POE) oils. The compressor is hermetically
sealed and incorporates internal high temperature motor
overload protection and durable insulation on the motor
windings. It is externally mounted on rubber grommets to
reduce vibration and noise.
2. Compressors have an internal pressure relief assembly to
protect against excessive pressure differential.
The Rheem Classic ® Series High Efficiency RANL- Con3. All refrigerant connections are on the exterior of the unit,
densing Units were designed with performance in mind.
located
the ground
for neat
appearing
installations.
These
units close
offer to
comfort,
energy
conservation
and
dependability
single, multi-family
and light
commercial
4. Cabinet for
is constructed
of powder
painted
galvanized
applications.
steel. The full wraparound louvered grille protects the coil
These
units
also contain the most advanced alternate
from
damage.
refrigerant which contains no chlorofluorocarbons (CFCs),
5.
Copper
tube—aluminum fin coils are used on all models.
or hydrochlorofluorocarbons (HCFCs), or other com6. Thethat
control
located
in the top systems
corner ofand
the cabinet
pounds
may box
leak is
from
air-conditioning
potentially
harmfor
theeasy
protective
ozone
layeraofservice
the Earth’s
providing
access
through
panel.
atmosphere.
7. Service valves are standard on all models.
The Rheem Classic ® Series RANL- Condensing Units are
8. result
Power
and
control
wiring are program
kept separate.
the
of an
ongoing
development
for improved
efficiencies.
These
arecharged
flexible enough
to achieve up
9. Every unit
is units
factory
and tested.
to 15.00 SEER in specific match-ups, continuing a tradition
10.high
Separate
compressor compartment for easy service access.
of
efficiency.
11.
Drawn,louvered
painted wrap-around
base pan forjacket
extraprotects
corrosion
and
Attractive,
the resistance
coil
from
yard reduction.
hazards and weather extremes. Top grille is
sound
steel reinforced for extra strength. Cabinet is powder
12.
Automatic reset high and low pressure controls are standard
painted for all-weather protection.
on all models.
Air is discharged upward away from bushes and shrubs.
13.
liquid linepattern
filter drier
standard
on all models
TheAdischarge
of theistop
grille provides
minimum(shipped –
not installed).
air restriction.
018
COOLING
CAPACITY
J
ELECTRICAL
DESIGNATION
A
Z
VARIATIONS
COOLING CONNECTION
FITTING
A-SERIES = FULL-FEATURED
018 = 18,000 BTU/HR [5.28 kW] J = 208/230V-1-60
Z = SWEAT W/SCROLL
C = 208/230V-3-60
024 = 24,000 BTU/HR [7.03 kW]
13 SEER MODELS
(RANL
MODELS
031 = 30,000 BTU/HR [8.79
kW] MATCHED
(IN CERTAIN
SYSTEMS)
ONLY)
037 = 36,000 BTU/HR [10.55 kW]
“Proper sizing and installation of equipment is critical to achieve optimal performance.
Split system air conditioners and heat pumps
D = 460V-3-60
043
= 42,000 BTU/HR
[12.31 kW]
must be matched with appropriate coil
components
to meet ENERGY
STAR criteria. Ask your local ECCO Sales Representative for details
(RANL
MODELS
049 = 48,000 BTU/HR
[14.07
kW]
or visit www.energystar.gov”
ONLY)
060 = 60,000 BTU/HR [17.58 kW]
Y = 575V-3-60
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice
–­ All4 Taxes
Extra – May not be Available at All Branches –
(RANL
& 5 TON
[ ] Designates Metric Conversions
MODELS ONLY)
3-8 www.eccosupply.ca
L = R-410A
ECCO supply
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
TECHNICAL DATA (cont’d)
RANL- *AZ (cont‘d)
Electrical and Physical Data: RANLELECTRICAL
Model
No.
RANL-
Phase
Frequency
(Hz)
Voltage
(Volts)
018JAZ
024JAZ
031JAZ
037CAZ
037DAZ
037JAZ
043CAZ
043DAZ
043JAZ
049CAZ
049DAZ
049JAZ
049YAZ
060CAZ
060DAZ
060JAZ
060YAZ
1-60-208/230
1-60-208/230
1-60-208/230
3-60-208/230
3-60-460
1-60-208/230
3-60-208/230
3-60-460
1-60-208/230
3-60-208/230
3-60-460
1-60-208/230
3-60-575
3-60-208/230
3-60-460
1-60-208/230
3-60-575
PHYSICAL
Compressor
Outdoor Coil
Fan
Fuse or HACR
Motor Min. Circuit Circuit Breaker
Rated
Locked
Full
Load
Ampacity
Load
Rotor
Face Area
No.
Amperes Amperes Amperes Amperes
Sq. Ft. [m2] Rows
Min.
Max.
(FLA)
(RLA)
(LRA)
Amperes Amperes
9/9
12.8/12.8
14.1/14.1
13.2/13.2
6
17.9/17.9
13.6/13.6
6.1
19.9/19.9
13.7/13.7
6.2
21.8/21.8
4.8
15.6/15.6
7.8
26.3/26.3
5.8
48
58.3
73
88
44
112
83.1
41
109
83.1
41
117
33
110
52
134
38.9
[ ] Designates Metric Conversions
0.6
0.6
0.6
1.2
0.6
1.2
1.2
0.6
1.2
1.2
0.6
1.2
0.5
1.2
0.6
1.2
0.5
12/12
17/17
19/19
18/18
9
24/24
19/19
9
27/27
19/19
9
29/29
7
21/21
11
35/35
8
15/15
20/20
25/25
25/25
15
30/30
25/25
15
35/35
25/25
15
35/35
15
25/25
15
45/45
15
20/20
25/25
30/30
30/30
15
40/40
30/30
15
45/45
30/30
15
50/50
15
35/35
15
60/60
15
9.07 [0.84]
11.00 [1.02]
11.06 [1.03]
16.10 [1.50]
16.10 [1.50]
16.10 [1.50]
16.10 [1.50]
16.10 [1.50]
16.10 [1.50]
20.13 [1.87]
23.13 [2.15]
20.13 [1.87]
20.13 [1.87]
23.01 [2.14]
23.01 [2.14]
23.01 [2.14]
23.01 [2.14]
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
CFM [L/s]
1775 [838]
1920 [906]
1920 [906]
3200 [1510]
3200 [1510]
3200 [1510]
3200 [1510]
3200 [1510]
3200 [1510]
3500 [1652]
3500 [1652]
3500 [1652]
3500 [1652]
3500 [1652]
3500 [1652]
3500 [1652]
3500 [1652]
Weight
Refrig.
Per
Circuit
Oz. [g]
Net
Lbs. [kg]
Shipping
Lbs. [kg]
70 [1984]
72 [2041]
83 [2353]
106 [3005]
106 [3005]
106 [3005]
115 [3260]
115 [3260]
115 [3260]
132 [3742]
132 [3742]
132 [3742]
132 [3742]
180 [5103]
180 [5103]
180 [5103]
180 [5103]
130 [59.0]
140 [63.5]
143 [64.9]
193 [87.5]
193 [87.5]
193 [87.5]
202 [91.6]
202 [91.6]
202 [91.6]
214 [97.1]
214 [97.1]
214 [97.1]
214 [97.1]
250 [113.4]
250 [113.4]
250 [113.4]
250 [113.4]
140 [63.5]
150 [68.0]
153 [69.4]
203 [92.1]
203 [92.1]
203 [92.1]
212 [96.2]
212 [96.2]
212 [96.2]
224 [101.6]
224 [101.6]
224 [101.6]
224 [101.6]
260 [117.9]
260 [117.9]
260 [117.9]
260 [117.9]
(cont’d on next page)
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
ECCO supply
www.eccosupply.ca 3-9
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
TECHNICAL DATA (cont’d)
RANL- *AZ (cont‘d)
Unit Dimensions
AIR DISCHARGE
ALLOW 60 [1524 mm] CLEARANCE
LOW VOLTAGE
CONNECTION
7/80 [22 mm]
W
SERVICE
FITTINGS
L
HIGH VOLTAGE
CONNECTION
111/320 [34 mm]
ACCESS
PANEL
H
003
A-00
AIR INLETS
(LOUVERS)
ALLOW 6 [152 mm]
MIN. CLEARANCE
3 SIDES
A-00
001
VAPOR LINE
CONNECTION
HIGH PRESSURE
CONTROL
MANUAL RESET
(FIELD INSTALLED
ACCESSORY)
ALLOW 24 [610 mm]
ACCESS CLEARANCE
LIQUID LINE
CONNECTION
SERVICE ACCESS
TO ELECTRICAL &
27/80 [73 mm] DIA. VALVES ALLOW
ACCESSORY
240 [610 mm]
KNOCKOUTS
CLEARANCE
ONE SIDE
Model Number
RANL018
Height “H”
(Inches) [mm]
19 [483]
Length “L”
(Inches) [mm]
351/2 [902]
Width “W”
(Inches) [mm]
233/4 [603]
024/031
19 [483]
401/2 [1029]
275/8 [702]
037/043
23 [584]
443/8 [1127]
311/2 [800]
049
060
29 [737]
33 [838]
443/8 [1127]
443/8 [1127]
311/2 [800]
311/2 [800]
[ ] Designates Metric Conversions
(cont’d on next page)
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.
Condenser Coil leaks caused by
factory defects ........................................Five (5) Years
Compressor—
JAZ ......................................................Ten (10) Years
CAZ, DAZ, YAZ..............................................Five (5) Years
*All Other Parts
JAZ ................................................................Five (5) Years
CAZ, DAZ, YAZ ........................................One (1) Year
*This five year limited warranty is applicable only to single-phase products
installed in residential applications on or after January 1, 2001.
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
3-10 www.eccosupply.ca
ECCO supply
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
TECHNICAL DATA (cont’d)
RANL- *AZ (cont‘d)
Condensing Unit Refrigerant Line Size Information
Liquid Line Sizing (R-410A)
Liquid Line Size – Outdoor Unit Above Indoor Coil
Liquid Line Size – Outdoor Unit Below Indoor Coil
(Cooling Only – Does not apply to Heat Pumps)
Line Size Line Size
Total Equivalent Length—Feet [m]
Total Equivalent Length—Feet [m]
System
Connection (Inch O.D.)
Capacity
25
50
75
100
125
150
25
50
75
100
125
150
(Inch I.D.)
[mm]
[7.62] [15.24] [22.86] [30.48] [38.10]
[45.72]
[7.62]
[15.24] [22.86] [30.48] [38.10] [45.72]
Minimum Vertical Separation—Feet [m]
Maximum Vertical Separation—Feet [m]
1/4* [6.35]
0
0
0
0
8 [2.44] 24 [7.32] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74]
N/A
N/A
3/8″
11/2 Ton
5/16 [7.94]
0
0
0
0
0
0
25 [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14.94]
3/8* [9.53]
1/4* [6.35]
0
0
3/8″
5/16 [7.94]
0
21/2 Ton
3/8″
3/8* [9.53]
1/4* [6.35]
5/16 [7.94]
0
0
0
3 Ton
3/8″
3/8* [9.53]
5/16* [7.94]
3/8* [9.53]
0
0
0
0
0
0
0
0
0
31/2 Ton
3/8″
5/16* [7.94]
0
0
0
4 Ton
3/8″
5 Ton
3/8″
3/8* [9.53]
3/8* [9.53]
1/2 [12.57]
3/8* [9.53]
1/2 [12.57]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2 Ton
0
0
0
0
0
25 [7.62] 50 [15.24] 75 [22.86] 72 [21.95] 70 [21.34] 68 [20.73]
3 [0.91] 29 [8.84] 55 [16.76] 81 [24.69] 108 [32.92] 23 [7.01]
N/A
N/A
N/A
N/A
N/A
0
0
0
0
0
0
14 [4.27] 56 [17.07] 98 [29.87]
0
0
0
0
0
0
0
0
25 [7.62] 36 [10.97] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74]
0
N/A
0
0
N/A
0
25 [7.62] 50 [15.24] 72 [21.95] 70 [21.34] 68 [20.73] 65 [19.81]
25 [7.62]
N/A
N/A
N/A
N/A
N/A
25 [7.62] 49 [14.94] 38 [11.58] 27 [8.23] 17 [5.18] 6 [1.83]
0
0
0
0
25 [7.62] 50 [15.24] 68 [20.73] 65 [19.81] 62 [18.90] 58 [17.68]
9 [2.74] 25 [7.62] 50 [15.24] 37 [11.28] 22 [6.71] 7 [2.13]
N/A
0
25 [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15]
16 [4.88] 35 [10.67] 54 [16.46] 25 [7.62] 23 [7.01] 4 [1.22]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
25 [7.62]
25 [7.62]
25 [7.62]
25 [7.62]
25 [7.62]
50 [15.24]
46 [14.02]
50 [15.24]
50 [15.24]
50 [15.24]
43 [13.11]
38 [11.58]
56 [17.07]
56 [17.07]
75 [22.86]
N/A
N/A
36 [10.97]
30 [9.14]
55 [16.76]
44 [13.41]
81 [24.69]
N/A
30 [9.14] 24 [7.32]
22 [6.71] 15 [4.57]
53 [16.15] 52 [15.85]
32 [9.75] 20 [6.10]
79 [24.08] 76 [23.16]
NOTES: *Standard line size
N/A = Application not recommended.
Suction Line Length/Size versus Capacity Multiplier (R-410A)
Unit Size
11/2 Ton
Suction Line
Connection Size
Suction Line Run—
Feet [m]
Optional
Standard
Optional
Optional
50' [15.24] Standard
Optional
Optional
100' [30.48] Standard
Optional
Optional
150' [45.72] Standard
Optional
25' [7.62]
2 Ton
3/4"
1.00
1.00
N/A
.98
.99
N/A
.95
.96
N/A
.92
.94
N/A
3 Ton
[19.05 mm] I.D.
5/8" [15.88 mm] O.D. Opt.
3/4" [19.05 mm] O.D. Std.*
1.00
1.00
N/A
.98
.99
N/A
.95
.96
N/A
.92
.93
N/A
21/2 Ton
5/8" [15.88 mm] O.D. Opt.
3/4" [19.05 mm] O.D. Std.*
7/8"
[22.23 mm] O.D. Opt.
1.00
1.00
1.00
.96
.98
.99
.94
.96
.97
.91
.93
.95
7/8"
1.00
1.00
N/A
.98
.99
N/A
.96
.97
N/A
.94
.95
N/A
1.00
1.00
N/A
.99
.99
N/A
.96
.98
N/A
.94
.96
N/A
4 Ton
5 Ton
[22.23 mm] I.D.
3/4" [19.05 mm] O.D. Opt.
7/8" [22.23 mm] O.D. Std.*
NOTES: *Standard line size
Using suction line larger than shown in chart will result in poor oil return and is not recommended.
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
31/2 Ton
7/8" [22.23 mm] O.D. Opt.
11/8" [28.58 mm] O.D. Std.*
1.00
1.00
N/A
.99
.99
N/A
.96
.98
N/A
.95
.96
N/A
1.00
1.00
N/A
.99
.99
N/A
.97
.98
N/A
.94
.97
N/A
[ ] Designates Metric Conversions
Rheem Heating,
Cooling and
Water Heating
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without no tice.”
PRINTED IN U.S.A.
11-08 DC
FORM NO. A11-184 REV. 8
Supersedes Form No. A11-184 Rev. 7
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
ECCO supply
www.eccosupply.ca 3-11
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
TECHNICAL DATA
13AJM- SERIES
FORM NO. A11-202 REV. 1
Supersedes Form No. A11-202
Electrical and Physical Data
ELECTRICAL
PHYSICAL
Fuse or HACR
Compressor
Model
Fan Motor Minimum
Refrigerant
Outdoor Coil
Phase
Circuit Breaker
Number
Full Load Circuit
Per
Rated
Load
Locked
Rotor
Frequency
[HZ]
13AJM
Amperes Ampacity Minimum Maximum Face Area No.
Circuit
Amperes
Voltage [Volts] Amperes
CFM
[L/s]
(FLA) Amperes Amperes Amperes Sq. Ft. [m2] Rows
Oz. [g]
(RLA)
(LRA)
Rev. 7/29/09
Weight
Net
Lbs. [kg]
Shipping
Lbs. [kg]
18
1-60-208/230
9/9
48
0.6
12/12
15/15
20/20
8.43 [0.78]
1
1675 [790] 75.2 [2132] 120 [54.4] 128 [58.1]
24
1-60-208/230
13.5/13.5
58.3
0.6
18/18
25/25
30/30
8.43 [0.78]
1
1665 [786] 73.8 [2092] 121 [54.9] 129 [58.5]
30
36
1-60-208/230
1-60-208/230
12.8/12.8
16.7/16.7
73
79
0.6
0.8
17/17
22/22
20/20
30/30
25/25
35/35
10.29 [0.96]
12.43 [1.15]
1
1
2075 [979] 86.8 [2440] 139 [63.1] 147 [66.7]
2805 [1324] 96 [2722] 159 [72.1] 167 [75.8]
42
1-60-208/230
17.9/17.9
112
0.8
24/24
30/30
40/40
16.39 [1.52]
1
3295 [1555] 126.4 [3583] 188 [85.3] 192 [87.1]
48
60
1-60-208/230
1-60-208/230
21.8/21.8
26.4/26.4
117
134
0.8
1.2
29/29
35/35
35/35
45/45
45/45
60/60
21.85 [2.03]
21.85 [2.03]
1
1
3295 [1555] 144 [4082] 207 [93.9] 218 [98.9]
3570 [1685] 176 [4990] 223 [101.2] 234 [106.1]
NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set.
Unit Dimensions
Model No.
13AJL
18, 24
30
36, 42
48, 60
Unit Dimensions
Width “W”
Inches
Length “L”
Inches
Height “H”
Inches
235/8 [600]
275/8 [702]
315/8 [803]
315/8 [803]
235/8 [600]
275/8 [702]
315/8 [803]
315/8 [803]
241/4 [616]
241/4 [616]
2715/16 [710]
3515/16 [913]
[ ] Designates Metric Conversions
w
detail a
LOW VOLTAge
7/8" [22 mm] HOLE DIAMETER
HIGH VOLTAge
1-11/32" [34 mm]
HOLE DIAMETER
L
SERVICE
FITTING
H
SERVICE
FITTING
2" [50.8 mm]
SEE DETAIL A
BASERAIL
LIQUID line
connection
vapor line
connection
(cont’d on next page)
13.0
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
3-12 www.eccosupply.ca
ECCO supply
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
TECHNICAL DATA (cont’d)
13AJM- SERIES (cont’d)
Condensing Unit Refrigerant Line Size Information
Liquid Line Sizing (R-410A)
Liquid Line Size – Outdoor Unit Above Indoor Coil
Liquid Line Size – Outdoor Unit Below Indoor Coil
(Cooling Only—Does not apply to Heat Pumps)
Liquid Line
Line Size
Total Equivalent Length—Feet [m]
Total Equivalent Length—Feet [m]
System Connection
(Inch O.D.)
Size
Capacity
25
50
75
100
125
150
25
50
75
100
125
150
[mm]
(Inch I.D.)
[7.62]
[15.24]
[22.86]
[30.48] [38.10]
[45.72]
[7.62]
[15.24] [22.86] [30.48] [38.10] [45.72]
Minimum Vertical Separation—Feet [m]
Maximum Vertical Separation—Feet [m]
1/4 [6.35]
0
0
0
0
8 [2.44] 24 [7.32] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74]
N/A
N/A
″
3/8
11/2 Ton
5/16* [7.94]
0
0
0
0
0
0
25 [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14.94]
[9.53]
3/8* [9.53]
0
0
0
0
0
0
25 [7.62] 50 [15.24] 75 [22.86] 72 [21.95] 70 [21.34] 68 [20.73]
1/4 [6.35]
0
3 [0.91] 29 [8.84] 55 [16.76] 81 [24.69] 108 [32.92] 23 [7.01]
N/A
N/A
N/A
N/A
N/A
″
3/8
2 Ton
5/16* [7.94]
0
0
0
0
0
0
25 [7.62] 36 [10.97] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74]
[9.53]
21/2 Ton
3/8″
[9.53]
3 Ton
3/8″
[9.53]
31/2
Ton
3/8″
[9.53]
4 Ton
3/8″
[9.53]
5 Ton
3/8″
[9.53]
3/8* [9.53]
1/4 [6.35]
5/16* [7.94]
3/8* [9.53]
5/16 [7.94]
0
0
0
0
0
0
0
0
14 [4.27] 56 [17.07] 98 [29.87]
0
0
0
0
0
0
0
0
0
0
0
N/A
0
0
0
0
25 [7.62]
N/A
25 [7.62]
0
25 [7.62]
0
25 [7.62]
9 [2.74] 25 [7.62]
0
0
50 [15.24]
N/A
49 [14.94]
50 [15.24]
50 [15.24]
72 [21.95]
N/A
38 [11.58]
68 [20.73]
37 [11.28]
70 [21.34] 68 [20.73] 65 [19.81]
N/A
N/A
N/A
27 [8.23] 17 [5.18] 6 [1.83]
65 [19.81] 62 [18.90] 58 [17.68]
22 [6.71] 7 [2.13]
N/A
3/8* [9.53]
0
0
0
5/16 [7.94]
0
0
0
25 [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15]
3/8* [9.53]
3/8* [9.53]
1/2 [12.57]
3/8* [9.53]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
25 [7.62]
25 [7.62]
25 [7.62]
25 [7.62]
1/2 [12.57]
0
0
0
0
0
0
25 [7.62] 50 [15.24] 75 [22.86] 81 [24.69] 79 [24.08] 76 [23.16]
16 [4.88] 35 [10.67] 54 [16.46] 25 [7.62] 23 [7.01] 4 [1.22]
50 [15.24]
46 [14.02]
50 [15.24]
50 [15.24]
43 [13.11]
38 [11.58]
56 [17.07]
56 [17.07]
N/A
N/A
N/A
36 [10.97] 30 [9.14] 24 [7.32]
30 [9.14] 22 [6.71] 15 [4.57]
55 [16.76] 53 [16.15] 52 [15.85]
44 [13.41] 32 [9.75] 20 [6.10]
NOTES: *Standard line size
N/A = Application not recommended.
Unit Size
Suction Line Connection Size
Suction Line Run—Feet [m]
25' [7.62]
50' [15.24]
100' [30.48]
150' [45.72]
Optional
Standard
Optional
Optional
Standard
Optional
Optional
Standard
Optional
Optional
Standard
Optional
11/2 Ton
Suction Line Length/Size versus Capacity Multiplier (R-410A)
2 Ton
21/2 Ton
3 Ton
3/4" [19.05] I.D.
5/8" [15.88 mm] O.D. Optional
3/4" [19.05 mm] O.D. Standard*
1.00
1.00
—
.98
.99
—
.95
.96
—
.92
.93
—
5/8" [15.88 mm] O.D. Optional
3/4" [19.05 mm] O.D. Standard*
7/8"
[22.23 mm] O.D. Optional
1.00
1.00
—
.98
.99
—
.95
.96
—
.92
.94
—
1.00
1.00
1.00
.96
.98
.99
.94
.96
.97
.91
.93
.95
31/2 Ton
4 Ton
7/8" [22.23] I.D.
3/4" [19.05 mm] O.D. Optional
7/8" [22.23 mm] O.D. Standard*
1.00
1.00
—
.98
.99
—
.96
.97
—
.94
.95
—
1.00
1.00
—
.99
.99
—
.96
.98
—
.94
.96
—
5 Ton
7/8" [22.23 mm] O.D. Optional
11/8" [28.58 mm] O.D. Standard*
1.00
1.00
—
.99
.99
—
.96
.98
—
.95
.96
—
1.00
1.00
—
.99
.99
—
.97
.98
—
.94
.97
—
NOTES: *Standard line size
Using suction line larger than shown in chart will result in poor oil return and is not recommended.
[ ] Designates Metric Conversions
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or visit www.Rheem.com.
Condenser Coil leaks caused by
factory defects ........................................Five (5) Years
Conditional Compressor* ............................Ten (10) Years
Any Other Part............................................Five (5) Years
*See Product Warranty Card for Details.
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice
–­ All Heating,
Taxes Extra
– Mayand
notWater
be Available
–
Rheem
Cooling
Heatingat All Branches
5
ECCO supply
www.eccosupply.ca 3-13
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
technical data (cont’d)
RAPMJAZ
RAPMJAZ
14.5 SEER Models
Efficiencies up to 16.00 SEER
Nominal Sizes 11/2 to 5 Tons
[5.28 kW] to [17.6 kW]
Seven Models
Cooling Capacities
18,600 to 62,500 BTU/HR
[5.45 kW] to [18.32 kW]
FORM NO. A11-199 REV. 1
Supersedes Form No. A11-199
Engineering Features
RAPM- Series Condensing Units
All controls and compressor are accessible
for servicing by removal of the service panel.
1. This unit contains a special scroll compressor that is
designed specifically to operate with R-410A refrigerants
and polyolester (POE) oils. The compressor is hermetically
sealed and incorporates internal high temperature motor
overload protection and durable insulation on the motor
windings. It is externally mounted on rubber grommets to
reduce vibration and noise.
2. Compressors have an internal pressure relief assembly to
protect against excessive pressure differential.
3. All refrigerant connections are on the exterior of the unit,
located close to the ground for neat appearing installations.
4. Cabinet is constructed of powder painted galvanized
steel. The full wraparound louvered grille protects the coil
from damage.
5. Copper tube—aluminum fin coils are used on all models.
6. The control box is located in the top corner of the cabinet
providing for easy access through a service panel.
7. Service valves are standard on all models.
8. Power and control wiring are kept separate.
9. Every unit is factory charged and tested.
10. Separate compressor compartment for easy service access.
11. Drawn, painted base pan for extra corrosion resistance and
sound reduction.
12. Automatic reset high and low pressure controls are standard
on all models.
13. A liquid line filter drier is standard on all models (shipped –
not installed).
Drawn Painted Base Pan.
(cont’d on next page)
IN CERTAIN MATCHED SYSTEMS
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be
matched with appropriate coil components to meet ENERGY STAR criteria. Ask your local ECCO Sales Representative for details or
visit www.energystar.gov.”
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
3-14 www.eccosupply.ca
ECCO supply
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
technical data (cont’d)
RAPM- JAZ (cont’d)
Electrical and Physical Data: RAPMELECTRICAL
Compressor
Model
Fan Motor
Phase
Number
Rated Load Locked Rotor Full Load
Frequency
(Hz)
RAPMAmperes
Amperes
Voltage (Volts) Amperes
(FLA)
(RLA)
(LRA)
Rev. 11/18/09
018JAZ 1-60-208/230
024JAZ 1-60-208/230
030JAZ 1-60-208/230
9/9
13.5/13.5
12.8/12.8
PHYSICAL
Fuse or HACR
Minimum
Refrig.
Outdoor Coil
Circuit Breaker
Circuit
Per
Ampacity Minimum Maximum Face Area No.
Circuit
CFM
[L/s]
Amperes Amperes Amperes Sq. Ft. [m2] Rows
Oz. [g]
Weight
Net
Lbs. [kg]
Shipping
Lbs. [kg]
48
58.3
64
1.9
1.1
1.9
14/14
18/18
18/18
20/20
25/25
25/25
20/20
30/30
30/30
11.00 [1.02]
20.00 [1.86]
20.00 [1.86]
1
1
1
2300 [1085] 82 [2325] 138.5 [62.8] 160.5 [72.8]
3300 [1557] 128 [3629] 192.5 [87.3] 214.5 [97.3]
3300 [1557] 129 [3657] 193
[87.5] 214 [97.1]
036JAZ 1-60-208/230
16/16
79
1.9
22/22
30/30
35/35
23.01 [2.14]
1
3300 [1557] 146 [4139] 197.5 [89.6] 227
042JAZ 1-60-208/230
048JAZ 1-60-208/230
060JAZ 1-60-208/230
17.9/17.9
21.8/21.8
26.4/26.4
112
117
134
2.8
2.8
2.8
26/26
31/31
36/36
30/30
40/40
45/45
40/40
50/50
60/60
23.01 [2.14]
23.01 [2.14]
23.00 [2.14]
1
2
2
3300 [1557] 152 [4309] 223 [101.2] 256 [116.1]
3300 [1557] 203 [5755] 264 [119.8] 298 [135.2]
3300 [1557] 262 [7428] 269.5 [122.2] 306.5 [139]
[103]
Unit Dimensions
AIR DISCHARGE
ALLOW 60 [1524 mm] CLEARANCE
LOW VOLTAGE
CONNECTION
7/80 [22 mm]
W
SERVICE
FITTINGS
L
HIGH VOLTAGE
CONNECTION
111/320 [34 mm]
ACCESS
PANEL
H
003
A-00
AIR INLETS
(LOUVERS)
ALLOW 6 [152 mm]
MIN. CLEARANCE
3 SIDES
ALLOW 24 [610 mm]
ACCESS CLEARANCE
001
A-00
Model Number
RAPM018
Height “H”
(Inches) [mm]
19 [483]
Length “L”
(Inches) [mm]
401/2 [1029]
Width “W”
(Inches) [mm]
275/8 [702]
024/030
29 [737]
443/8 [1127]
311/2 [800]
036/042/
048/060
33 [838]
443/8 [1127]
311/2 [800]
VAPOR LINE
CONNECTION
HIGH PRESSURE
CONTROL
MANUAL RESET
(FIELD INSTALLED
ACCESSORY)
LIQUID LINE
CONNECTION
SERVICE ACCESS
TO ELECTRICAL &
27/80 [73 mm] DIA. VALVES ALLOW
ACCESSORY
240 [610 mm]
KNOCKOUTS
CLEARANCE
ONE SIDE
[ ] Designates Metric Conversions
(cont’d on next page)
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited
warranty.
*For Complete Details of the Limited Warranty, Including Applicable
Terms and Conditions, See Your Local Installer or Contact the
Manufacturer for a Copy.
Condenser Coil leaks caused by
factory defects ........................................Five (5) Years
Compressor—
JAZ ......................................................Ten (10) Years
Conditional Parts*
(Registration Required) ................................Ten (10) Years
*This five year limited warranty is applicable only to single-phase products
installed Notice
in residential
afternot
January
1, 2001. at All Branches –
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without
–­ All applications
Taxes Extraon– or
May
be Available
ECCO supply
20
Rheem Heating, Cooling and Water Heating
www.eccosupply.ca 3-15
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
technical data (cont’d)
RAPM- JAZ (cont’d)
Condensing Unit Refrigerant Line Size Information
Liquid Line Sizing (R-410A)
Liquid Line Size – Outdoor Unit Above Indoor Coil
Liquid Line Size – Outdoor Unit Below Indoor Coil
(Cooling Only – Does not apply to Heat Pumps)
Line Size Line Size
Total Equivalent Length—Feet [m]
Total Equivalent Length—Feet [m]
System
Connection (Inch O.D.)
Capacity
25
50
75
100
125
150
25
50
75
100
125
150
(Inch I.D.)
[mm]
[7.62] [15.24] [22.86] [30.48] [38.10]
[45.72]
[7.62]
[15.24] [22.86] [30.48] [38.10] [45.72]
Minimum Vertical Separation—Feet [m]
Maximum Vertical Separation—Feet [m]
1/4* [6.35]
0
0
0
0
8 [2.44] 24 [7.32] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74]
N/A
N/A
3/8″
11/2 Ton
5/16 [7.94]
0
0
0
0
0
0
25 [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14.94]
2 Ton
21/2 Ton
3/8* [9.53]
1/4* [6.35]
0
0
3/8″
5/16 [7.94]
0
3/8″
3/8* [9.53]
1/4* [6.35]
5/16 [7.94]
0
0
0
3/8* [9.53]
5/16* [7.94]
3/8* [9.53]
0
0
0
0
0
0
0
0
0
5/16* [7.94]
0
0
0
3/8* [9.53]
3/8* [9.53]
1/2 [12.57]
3/8* [9.53]
1/2 [12.57]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
3 Ton
3/8″
31/2 Ton
3/8″
4 Ton
3/8″
5 Ton
3/8″
0
0
0
0
0
25 [7.62] 50 [15.24] 75 [22.86] 72 [21.95] 70 [21.34] 68 [20.73]
3 [0.91] 29 [8.84] 55 [16.76] 81 [24.69] 108 [32.92] 23 [7.01]
N/A
N/A
N/A
N/A
N/A
0
0
0
0
0
0
14 [4.27] 56 [17.07] 98 [29.87]
0
0
0
0
0
0
0
0
25 [7.62] 36 [10.97] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74]
0
N/A
0
0
N/A
0
25 [7.62] 50 [15.24] 72 [21.95] 70 [21.34] 68 [20.73] 65 [19.81]
25 [7.62]
N/A
N/A
N/A
N/A
N/A
25 [7.62] 49 [14.94] 38 [11.58] 27 [8.23] 17 [5.18] 6 [1.83]
0
0
0
0
25 [7.62] 50 [15.24] 68 [20.73] 65 [19.81] 62 [18.90] 58 [17.68]
9 [2.74] 25 [7.62] 50 [15.24] 37 [11.28] 22 [6.71] 7 [2.13]
N/A
0
25 [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15]
16 [4.88] 35 [10.67] 54 [16.46] 25 [7.62] 23 [7.01] 4 [1.22]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
25 [7.62]
25 [7.62]
25 [7.62]
25 [7.62]
25 [7.62]
50 [15.24]
46 [14.02]
50 [15.24]
50 [15.24]
50 [15.24]
43 [13.11]
38 [11.58]
56 [17.07]
56 [17.07]
75 [22.86]
N/A
36 [10.97]
30 [9.14]
55 [16.76]
44 [13.41]
81 [24.69]
N/A
N/A
30 [9.14] 24 [7.32]
22 [6.71] 15 [4.57]
53 [16.15] 52 [15.85]
32 [9.75] 20 [6.10]
79 [24.08] 76 [23.16]
NOTES: *Standard line size
N/A = Application not recommended.
Suction Line Length/Size versus Capacity Multiplier (R-410A)
Unit Size
11/2 Ton
Suction Line
Connection Size
Suction Line Run—
Feet [m]
25' [7.62]
Optional
Standard
Optional
Optional
50' [15.24] Standard
Optional
Optional
100' [30.48] Standard
Optional
Optional
150' [45.72] Standard
Optional
2 Ton
3/4"
1.00
1.00
N/A
.98
.99
N/A
.95
.96
N/A
.92
.94
N/A
3 Ton
[19.05 mm] I.D.
5/8" [15.88 mm] O.D. Opt.
3/4" [19.05 mm] O.D. Std.*
1.00
1.00
N/A
.98
.99
N/A
.95
.96
N/A
.92
.93
N/A
21/2 Ton
5/8"
3/4"
7/8"
[15.88 mm] O.D. Opt.
[19.05 mm] O.D. Std.*
[22.23 mm] O.D. Opt.
1.00
1.00
1.00
.96
.98
.99
.94
.96
.97
.91
.93
.95
31/2 Ton
7/8"
1.00
1.00
N/A
.99
.99
N/A
.96
.98
N/A
.94
.96
N/A
5 Ton
[22.23 mm] I.D.
3/4" [19.05 mm] O.D. Opt.
7/8" [22.23 mm] O.D. Std.*
1.00
1.00
N/A
.98
.99
N/A
.96
.97
N/A
.94
.95
N/A
4 Ton
7/8" [22.23 mm] O.D. Opt.
11/8" [28.58 mm] O.D. Std.*
1.00
1.00
N/A
.99
.99
N/A
.96
.98
N/A
.95
.96
N/A
1.00
1.00
N/A
.99
.99
N/A
.97
.98
N/A
.94
.97
N/A
NOTES: *Standard line size
[ ] Designates Metric Conversions
Using suction line larger than shown in chart will result in poor oil return and is not recommended.
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
3-16 www.eccosupply.ca
ECCO supply
[14.06 kW]
60 = 60,000 BTU/HR
[17.58 kW]
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
Cased Coil Airflow:
HM = A/C or Heat Pump, Multi-Position
Uncased Coil Airflow:
HU = A/C or Heat Pump, Upflow/Downflow
Refrigerant
M = R-410A (16 SEER)
RHEEM RESIDENTIAL AIR CONDITIONING
F = Product Generation
www.rheem.com
Classification
C = Coil
technical data (cont’d)
Rheem
INDOOR COILS — RCFM-
FORM NO. C11-212 REV. 3
Supersedes Form No. C11-212 Rev. 2
Table 1: Coil Specifications/Airflow Pressure Drop
Coil
Model
Number
Approx.
Design
Air Flow
CFM [L/s]
Range
Face
Area
Sq. Ft.
[m2]
Fins-in.
Rows
Deep
Static Pressure Drop Through Wet Cooling Coil [kPa] (Inches W.C.) CFM [L/s]
600
[283]
700
[330]
800
[378]
900
[425]
1000
[472]
1100
[519]
.12
[.029]
.10
[.025]
.17
[.042]
.15
[.037]
.17
[.042]
.15
[.037]
.21
[.052]
.18
[.045]
.21
[.052]
.18
[.045]
.26
[.065]
.23
[.057]
.31
[.077]
.27
[.067]
1200
[566]
1300
[614]
1400
[661]
1500
[708]
1600
[756]
1700
[802]
1800
[850]
1900
[897]
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
.36
[.09]
.31
[.077]
.22
[.055]
.22
[.055]
.41
[.102]
.37
[.092]
.25
[.062]
.25
[.062]
.17
[.042]
—
—
—
—
—
—
—
—
—
—
—
—
.28
[.07]
.28
[.07]
.20
[.05]
.32
[.08]
.32
[.08]
.024
[.058]
.36
[.09]
.36
[.09]
.27
[.067]
.41
[.102]
.41
[.102]
.30
[.075]
—
—
HIGH EFFICIENCY COOLING COILS
600/800
[283/376]
600/800
[283/376]
900/1200
[424/566]
900/1200
[424/566]
1200/1600
[566/755]
1200/1600
[566/755]
1300/1700
[614/802]
2417
2421
3617
3621
4821
4824
6024
5.70
[0.53]
5.70
[0.53]
5.70
[0.53]
5.70
[0.53]
8.55
[0.79]
8.55
[0.79]
9.98
[0.93]
.07
[.017]
.05
[.014]
16/2
16/2
16/2
—
—
16/2
—
—
16/2
—
—
—
—
—
—
16/2
—
—
—
—
—
—
14/3
—
—
—
—
—
—
—
—
—
.34
[.085]
.37
[.092]
NOTE: Represents Coil-Only Airflow Ratings
[ ] Designates Metric Conversions
Table 2: Coil Dimensions and Weights
Coil
Model
Number
2
Connections
Sweat (in.) [mm]
Liquid I.D.
2417
3/8
2421
3/8
3617
Cased Coil Dimensions
(in) [mm]
Suction I.D.
C
Coil Weight
(lbs.) [Kg.]
Shipping Weight
(lbs.) [Kg.]
[454]
20 [508]
52 [24]
57 [26]
171/2 [445]
20 [508]
52 [24]
60 [27]
171/2 [445]
20 [508]
52 [24]
57 [26]
21 1/2[533]
171/2 [445]
20 [508]
54 [24]
60 [27]
21 1/2[533]
257/8 [657]
28 [711]
76 [34]
83 [38]
241/2 [622]
Heating
241/2 [622]
253/8 [645]
301/4 [768]
32 [812]
32 [812]
89 [40]
108 [49]
99 [45]
118 [54]
A
[9.53]
3/4
[19.05]
171/2
[9.53]
3/4
[19.05]
21 1/2[533]
3/8
[9.53]
3/4
[19.05]
171/2 [445]
3621
3/8
[9.53]
3/4
[19.05]
4821
3/8
[9.53]
7/8
[22.23]
4824
Rheem
6024
3/8
[9.53]
3/8 [9.53]
Heating,
Cooling
7/8
[22.23]
7/8 [22.23]
and
Water
Weight
[445]
B
177/8
(cont’d on next page)
FIGURE 1: DIMENSIONS
A MINUS ONE INCH
PLENUM WIDTH
197/8
[505 mm]
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
FRONT VIEW
ECCO supply
www.eccosupply.ca 3-17
NOTE:
FLANGES ARE
PROVIDED
Table 2: Coil Dimensions and Weights
Coil
Model
Number
Connections
Sweat (in.) [mm]
Liquid I.D.
Cased Coil Dimensions
(in) [mm]
Suction I.D.
Weight
Pricing Effective: June 2011
Shipping
Weight
Coil Weight
Revised:
June
2011 • Replaces:
October 2006
(lbs.) [Kg.]
(lbs.) [Kg.]
A
B
C
20 [508]
20 [508]
52 [24]
57 [26]
52 [24]
60 [27]
2417
2421
3/8
[9.53]
3/4
[19.05]
171/2 [445]
177/8 [454]
3/8
[9.53]
3/4
[19.05]
21 1/2[533]
171/2 [445]
3617
3/8
[9.53]
3/4
[19.05]
171/2 [445]
3621
4821
3/8
[9.53]
3/8 [9.53]
3/4
[19.05]
7/8 [22.23]
21 1/2[533]
21 1/2[533]
257/8 [657]
28 [711]
76 [34]
83 [38]
4824
6024
3/8
7/8
241/2 [622]
241/2 [622]
253/8 [645]
301/4 [768]
32 [812]
32 [812]
89 [40]
108 [49]
99 [45]
118 [54]
[9.53]
3/8 [9.53]
17 / [445]
20 [508]
52 [24]
57 [26]
RHEEM
RESIDENTIAL
AIR
CONDITIONING
17 / [445]
20 [508]
54 [24]
60 [27]
[22.23]
7/8 [22.23]
technical data (cont’d)
12
12
www.rheem.com
INDOOR COILS — RCFM- (cont’d)
FIGURE 1: DIMENSIONS
A MINUS ONE INCH
197/8
[505 mm]
PLENUM WIDTH
FRONT VIEW
SIDE VIEW
1/2
NOTE:
FLANGES ARE
PROVIDED
FOR FIELD
INSTALLATION
[12.7 mm]
17/16
[36.5 mm]
SUCTION LINE
7/16
[11.1 mm]
LIQUID LINE
515/16
[150.8 mm]
53/8
[136.5 mm]
PRIMARY DRAIN
3/4 N.P.T.
(VERTICAL &
HORIZONTAL)
113/16 [46 mm]
11/4
[31.7 mm]
41/8
[104.7 mm]
2111/16
[550.8 mm]
21/4 [57.1 mm]
SECONDARY DRAIN
3/4 N.P.T. (VERTICAL)
[ ] Designates Metric Conversions
PRIMARY DRAIN
3/4 N.P.T. (VERTICAL)
Casing top and bottom openings are the same dimensions.
(cont’d on next page)
Rheem Heating, Cooling and Water Heating
3
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
3-18 www.eccosupply.ca
ECCO supply
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
technical data (cont’d)
INDOOR COILS — RCFM- (cont’d)
Table 3: Coil Application
Coils can be matched to heating products as listed in table below.
Furnace Width
(In.) (mm)
Coil Model
Oil*
2417
3617
Gas
—
14
2417
3617
21
[533]
2421
3621
4821
21
[533]
4824
6024
[356]
171/2 [444]
14 [356]
21
[533]
171/2
[444]
241/2 [622]
21 [533]
241/2 [622]
*Note: Due to the proximity of the drain pan to the high temperature oil furnace drum, horizontal left application is NOT permitted on all oil furnaces.
Accessories
• PLENUM ADAPTER ACCESSORY
RXBA-AE
This plenum adapter accessory is for use with the 24 1/2" wide
cased indoor cooling and heat pump coils. This allows a 241/2"
wide cased coil to be installed on a 28" wide oil furnace. This is a
field-installed accessory only.
• RXBA-AC (Upflow/Horizontal)
These plenum adapter accessories are for use when a cooling
coil is matched with a gas furnace of one smaller size.
• HORIZONTAL ADAPTER KIT RXHH (See Figure 2)
This horizontal adapter kit is used to convert a upflow or downflow
coil for a horizontal application. See Table 4 to order the proper
horizontal adapter kit.
• INDOOR COIL CASING- RXBC (See Table 5)
R
X
B
C
—
D
17
I
INSULATION
I = Insulated
Blank = Uninsulated
CABINET WIDTH
17 = 17.5" [444 mm]
21 = 21" [533 mm]
24 = 24.5" [622 mm]
DESIGN SERIES
COIL CASING
BLOWER UNIT
ACCESSORY
RHEEM
[ ] Designates Metric Conversions
(cont’d on next page)
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
ECCO supply
www.eccosupply.ca 3-19
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
technical data (cont’d)
INDOOR COILS — RCFM- (cont’d)
Accessories (cont’d)
Table 4: Horizontal Adapter Kit Model No.
Coil Model
2417/3617/3621
4821/4824
6024
Horizontal Adapter Kit Model No.
RXHH-A03
RXHH-A04
RXHH-A05
FIGURE 2: HORIZONTAL ADAPTER KIT ILLUSTRATION
Table 5: Unit Dimensions and Weights- RXBC Indoor Coil Casings
Model
Number
Depth
Width
Height
(in.)
(in.) [mm] (in.) [mm]
[mm]
Supply Air/Return
Air Openings
Unit Weight
Weight
Ship. Wt.
Width
(lbs.) [Kg.] (lbs.) [Kg.] (in.) [mm]
Depth
(in.)
[mm]
RXBC-D17AI 171/2 [445] 20 [508]
18 [8]
23 [10]
161/2 [419]
RXBC-D21AI 21 [533] 20 [508] 215/8
RXBC-D21BI 21 [533] 28 [711] [549]
RXBC-D24AI 241/2 [622] 321/2 [826]
20 [9]
27 [12]
34 [16]
26 [12]
36 [17]
44 [20]
20 [508] 1931/32
20 [508] [508]
231/2 [597]
• TXV REPLACEMENT KITS – RXCT
AIR FLOW
HORIZONTAL-DUAL
DIRECTION
Coil Model
RC*M-H*24*
RC*M-H*36*
RC*M-H*48*
RC*M-H*60*
R-410A
TXV Kit
RXCT-FBA
RXCT-FBB
RXCT-FBD
RXCT-FBE
Obsolete Kit Part No.
611020
611021
611023
None
NOTE: Valve can be R-22 or R-410A if date code is M2308 or later.
• TXV CONVERSION KITS – RXCT
HORIZONTAL ADAPTER KIT (RXHH-)
Coil Model
RC*A-H*36*
RC*A-H*36*
RC*A-H*48*
RC*A-H*60*
R-22 to R-410A
TXV Kit
RXCT-FBA
RXCT-FBB
RXCT-FBD
RXCT-FBE
Makes Coil
RC*M-H*24*
RC*M-H*36*
RC*M-H*48*
RC*M-H*60*
Coil Model
RC*M-H*24*
RC*M-H*36*
RC*M-H*48*
RC*M-H*60*
R-410A to R-22
TXV Kit
RXCT-EBB
RXCT-EBB
RXCT-EBC
RXCT-EBD
Makes Coil
RC*A-H*36*
RC*A-H*36*
RC*A-H*48*
RC*A-H*60*
NOTE: Valve can be R-22 or R-410A if date code is M2308 or later.
[ ] Designates Metric Conversions
(cont’d on next page)
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
3-20 www.eccosupply.ca
ECCO supply
Pricing Effective: June 2011
Revised: June 2011 • Replaces: October 2006
RHEEM RESIDENTIAL AIR CONDITIONING
www.rheem.com
technical data (cont’d)
INDOOR COILS — RCFM- (cont’d)
Accessories (cont’d)
• UNCASED COIL ADAPTER KIT
RXBA- (See Figure 3 & 4)
This uncased coil adapter kit is used to adapt the coil to a furnace
or ductwork. See Table 6 to order the proper adapter kit. Each kit
contains a quantity of 20 adapters.
FIGURE 3: UNCASED COIL ADAPTER KIT ILLUSTRATION
Table 6: Uncased Coil Adapter Kit
Uncased Coil Adapter
Model Number RXBA
A
Width (in.) [mm]
Uncased Coil
Model RCFA/L
B14x20
B17x20
131/8 [333]
165/8 [422]
-HUxx14
-HUxx17
B21x20
B24x20
201/8 [511]
235/8 [599]
-HUxx21
-HUxx24
[ ] Designates Metric Conversions
11/2
[41 mm]
711/16
[196 mm]
A
205/16
[516 mm]
FIGURE 4: UNCASED COIL ADAPTER KIT ASSEMBLED
Note: Sliding the coil into the coil rail before attaching coil rack front.
– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice –­ All Taxes Extra – May not be Available at All Branches –
ECCO supply
www.eccosupply.ca 3-21

Similar documents

Rheem Classic® Series Upflow/Horizontal Gas Furnace

Rheem Classic® Series Upflow/Horizontal Gas Furnace For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, direct spark ignition is 100% safety lockout type.

More information