HYDRAULIC FILTRATION FR-1 series Tank top return filters Technical Information Housing Pressure: Max working 8 bar (116 psi) (acc. to NFPA T 3.10.5.1) Burst 16 bar (232 psi) (acc. to NFPA T 3.10.5.1) Connection Ports: 3/8”÷2” BSP (other thread options on request) Materials: Cover: Head: Bowl: Seal: aluminium alloy aluminium alloy nylon (size 10 to 43) - zinc plated steel (size 50 to 64) NBR (FKM on request) By-pass: 1,7 bar (24.6 psi) Element Filter Media: Microglass fiber 4,5 - 7 - 12 - 27 µm(c) (acc. to ISO 16889) Cellulose 10 - 25 µm(c) (acc. to ISO 16889) Wire mesh 60 - 125 µm Differential collapse pressure: 10 bar (145 psi) (acc. to ISO 2941) Common Filtrec elements are tested also according to ISO 2942, ISO 23181 and ISO 3968 Working temperature: -25°C +100°C (-13°F +212°F) Fluid compatibility (acc. to ISO 2943): Full with HH-HL-HM-HV (acc. to ISO 6743/4). For use with other fluid applications please contact Filtrec Customer Service ([email protected]). w w w. f i l t r e c . c o m FR-1 series Ordering information MEDIA 000 G03 G06 G10 G25 C10 C25 T60 T125 Filter assembly FR-1 Filter element R-1 no element microglass fiber ß4,5 µm (C) >1000 microglass fiber ß7 µm (C) >1000 microglass fiber ß12 µm (C) >1000 microglass fiber ß27 µm (C) >1000 cellulose ß10 µm (C) >2 cellulose ß25 µm (C) >2 wire mesh 60 µm wire mesh 125 µm NOMINAL SIZE MEDIA 30 G10 B B 30 G10 B B SEALS CONNECTION FILLINGPLUG B4 0 INDICATOR POSITION INDICATOR C R10 SEALS B V NBR (omit for spare element) FKM CONNECTION B2 B3 B4 B5 B6 B7 B8 3/8” BSP 1/2” BSP 3/4” BSP 1” BSP 1 1/4” BSP 1 1/2” BSP 2” BSP For different thread options please check availability with Filtrec Customer Service. FILLING PLUG 0 T no filling plug with filling plug INDICATOR POSITION 0 C no indicator - no hole on the cover+plug INDICATOR 000 R2 R3 R6 R7 R9 R10 no indicator pressure switch N.O. 1,3 bar / 18,9 psi pressure switch N.C. 1,3 bar / 18,9 psi visual pressure 1,3 bar / 18,9 psi pressure vacuum gauge -1÷5 bar / -14,5÷72,5 psi pressure gauge 0÷4 bar / 0÷58 psi pressure gauge 0÷4 bar / 0÷58 psi Preferential option FR-1 series 2 Overall dimensions TANK MOUNTING PATTERN FR - 1 - 10 / 11 / 20 / 22 / 30 / 31 INDICATOR PORT B1 D1 ° 90 FILLING PLUG 3/8” M 2 HOLES Ø TANK MOUNTING PATTERN FR - 1 - 40 / 43 INDICATOR PORT R element removal B1 D1 A B2 0° 12 45° H2 H3 B3 FILLING PLUG 1” M 3 HOLES Ø TANK MOUNTING PATTERN FR - 1 - 50 / 51 / 60 / 64 90° H1 INDICATOR PORT D1 H4 B1 30° FILLING PLUG 1” D2 M 4 HOLES Ø D3 Nominal size CODE FR-1-10 FR-1-11 FR-1-20 FR-1-22 FR-1-30 FR-1-31 FR-1-40 FR-1-43 FR-1-50 FR-1-51 FR-1-60 FR-1-64 A B1 B2 B3 D1 3/8”-1/2” BSP 89 25 51 67,5 24 1/2”-3/4” BSP 3/4”-1” BSP D2 28 115 28,5 67 88,5 40 1”-1 1/4”-1 1/2” BSP 175 1 1/4”-1 1/2”-2” BSP 35 95 130 50 220 42 115 175 H1 H2 82 67 60 155 106 151 87 73 232 336 241 129 90 287 181 174 240 105 63 1 1/2” -2” BSP D3 289 H3 H4 8 22 24 24 11 30 50 M R 150 M6 220 190 230 M8 310 420 320 360 270 M10 340 WEIGHT 0,45 Kg 0,60 Kg 0,80 Kg 0,90 Kg 1,10 Kg 1,30 Kg 2,10 Kg 2,40 Kg 3,20 Kg 3,60 Kg 3,60 Kg 380 4,20 Kg FR-1 series 3 Pressure drop diagrams The total Pressure Drop (Dp) value is obtained by adding the Dp values of filter housing and filter element at the given flow rate. This ideally should not exceed 0,5 bar (7,3 psi) and should never exceed 1/3 of the set value of the by-pass valve. Housing FR-1-10/11 PRESSURE DROP THROUGH THE FILTER HOUSING The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. Flow rate (gpm) 0 5 10 9 0.6 8 0.5 7 6 0.4 5 0.3 The Pressure Drop through the filter element is related both to the internal diameter of the filter element and to the filter media; this value is affected by the oil viscosity in a roughly proportional way: e.g. when the Dp value from the curve is 0,2 bar and a 46 cSt oil is used, the corresponding value is 0,31 (=0,2 x 46/30) bar. 4 ∆p (psi) PRESSURE DROP THROUGH THE CLEAN FILTER ELEMENT 3 0.2 2 0.1 1 0.1 0 10 20 30 40 50 0 Flow rate (l/min) Element R-1-10 Element R-1-11 ∆p (psi) Flow rate (gpm) ∆p (psi) Flow rate (gpm) T60-T125 T60-T125 Flow rate (l/min) Flow rate (l/min) FR-1 series 4 Pressure drop diagrams Housing FR-1-20/22 PRESSURE DROP THROUGH THE FILTER HOUSING The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. Flow rate (gpm) 0 5 10 15 20 25 9 0.6 8 0.5 7 6 0.4 5 0.3 The Pressure Drop through the filter element is related both to the internal diameter of the filter element and to the filter media; this value is affected by the oil viscosity in a roughly proportional way: e.g. when the Dp value from the curve is 0,2 bar and a 46 cSt oil is used, the corresponding value is 0,31 (=0,2 x 46/30) bar. 4 3 0.2 2 0.1 1 0 0 20 40 10 15 20 25 0 100 80 Element R-1-20 Flow rate (gpm) 5 60 Flow rate (l/min) Housing FR-1-30/31 0 ∆p (psi) PRESSURE DROP THROUGH THE CLEAN FILTER ELEMENT 30 35 Flow rate (gpm) 40 9 0.6 8 0.5 7 0.4 4 0.2 ∆p (psi) 5 0.3 ∆p (psi) 6 3 2 0.1 1 0.0 0 30 60 90 120 150 T60-T125 0 Flow rate (l/min) Flow rate (l/min) Element R-1-22 Element R-1-30 Flow rate (gpm) Flow rate (gpm) 10 15 20 25 30 35 40 ∆p (psi) 5 ∆p (psi) 0 T60-T125 0 Flow rate (l/min) 30 60 90 Flow rate (l/min) T60-T125 120 150 Element R-1-31 Flow rate (gpm) 5 10 15 20 25 30 35 40 ∆p (psi) 0 T60-T125 0 30 60 90 Flow rate (l/min) 120 150 FR-1 series 5 Pressure drop diagrams Housing FR-1-40/43 PRESSURE DROP THROUGH THE FILTER HOUSING The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. 0 20 10 Flow rate (gpm) 30 40 50 60 0.6 8 0.5 7 6 0.4 5 0.3 The Pressure Drop through the filter element is related both to the internal diameter of the filter element and to the filter media; this value is affected by the oil viscosity in a roughly proportional way: e.g. when the Dp value from the curve is 0,2 bar and a 46 cSt oil is used, the corresponding value is 0,31 (=0,2 x 46/30) bar. 4 0.2 3 2 0.1 1 0.0 0 50 20 150 0 250 200 Element R-1-43 Flow rate (gpm) 30 100 Flow rate (l/min) Element R-1-40 10 ∆p (psi) PRESSURE DROP THROUGH THE CLEAN FILTER ELEMENT 0 9 40 50 60 0 20 10 Flow rate (gpm) 30 40 50 60 1.2 1.2 15 1 15 1 ∆p (psi) 10 10 0.6 0.6 0.4 0.4 5 5 0.2 0.2 T60-T125 0.0 0 50 100 150 200 0 250 0.0 0 Flow rate (l/min) 50 100 T60-T125 150 Flow rate (l/min) FR-1 series 6 200 0 250 ∆p (psi) 0.8 0.8 Pressure drop diagrams Housing FR-1-50/51 PRESSURE DROP THROUGH THE FILTER HOUSING The Pressure Drop through the filter housing is governed by the port, not the bowl length and the oil viscosity. Flow rate (gpm) 0 20 40 60 80 100 120 140 160 0.6 9 8 0.5 7 6 0.4 5 0.3 The Pressure Drop through the filter element is related both to the internal diameter of the filter element and to the filter media; this value is affected by the oil viscosity in a roughly proportional way: e.g. when the Dp value from the curve is 0,2 bar and a 46 cSt oil is used, the corresponding value is 0,31 (=0,2 x 46/30) bar. 4 0.2 3 2 0.1 1 0 0 120 240 40 60 80 100 600 Flow rate (gpm) 120 140 160 9 1.2 0 20 40 60 80 100 120 140 160 8 0.5 6 5 0.3 4 0.8 ∆p (psi) 0.4 10 0.6 0.4 3 0.2 2 0.1 15 1 7 5 0.2 T60-T125 1 0 120 240 360 480 0.0 0 600 0 0 120 240 Flow rate (l/min) 40 60 80 100 600 Element R-1-60 Flow rate (gpm) 20 480 Flow rate (l/min) Element R-1-51 0 360 Flow rate (gpm) 120 140 160 0 1.2 20 40 60 80 100 120 140 160 1.2 15 1 15 1 0.8 10 0.6 0.4 ∆p (psi) 0.8 10 0.6 0.4 5 0.2 ∆p (psi) 0.0 0 ∆p (psi) 20 480 Element R-1-50 Flow rate (gpm) 0 360 Flow rate (l/min) Housing FR-1-60/64 0.6 ∆p (psi) PRESSURE DROP THROUGH THE CLEAN FILTER ELEMENT 5 0.2 T60-T125 0.0 120 240 360 480 T60-T125 0 0 0.0 600 0 Flow rate (l/min) 120 240 360 480 600 Flow rate (l/min) Element R-1-64 Flow rate (gpm) 0 20 40 60 80 100 120 140 160 1.2 15 1 10 0.6 0.4 ∆p (psi) 0.8 5 0.2 T60-T125 0.0 0 120 240 360 480 0 600 Flow rate (l/min) FR-1 series 7 Pressure drop diagrams By-pass FR-1-10/31 PRESSURE DROP THROUGH THE BY-PASS VALVE Flow rate (gpm) The by-pass valve is a safety device to prevent element collapse in case of differential pressure peaks due to flow peaks, cold start conditions or when the clogged element is not replaced in a timely manor. 3.6 3.0 ∆p (psi) 2.4 1.8 1.2 0.6 30 60 90 120 150 Flow rate (l/min) By-pass FR-1-40/64 Flow rate (gpm) 3.6 3.0 ∆p (psi) 2.4 1.8 1.2 0.6 120 240 360 480 600 Flow rate (l/min) The above diagrams have been obtained at the FILTREC laboratory, according to the ISO 3968 specification, with mineral oil having 30 cSt viscosity and 0,86 Kg/dm3 density. In case of discrepancy, please check contamination level, viscosity and features of the oil in use and the sampling points of the differential pressure. FR-1 series 8 Clogging indicator The Pressure Drop (Dp) through the filter increases during the system operation due to the contaminant retained by the filter element. The filter element must be replaced when the indicator shows and before the Dp reaches the by-pass value setting. N.B. in cold start conditions a false alarm can be caused by higher oil viscosity due to low temperature; the indicator alarm must be considered at normal working temperature only. The clogging indicator registers the pressure upstream the filter element: •in the VISUAL indicator the red area shows the need for element replacement. •in the ELECTRIC indicator an electrical switch is activated. PRESSURE SWITCH SYMBOL - R2 FASTON SYMBOL - R3 2 42 1 CODE SETTING R2 1,3 bar (18,9 psi) N.O. R3 1,3 bar (18,9 psi) N.C. • Current: 0,5 A resistive/ 0,2 A inductive • Max voltage: 30-48 V DC • Protection: IP54 as per DIN 40050 24 1/8” BSP VISUAL PRESSURE GAUGE CODE SETTING R6 1,3 bar (18,9 psi) 9 71 SYMBOL 1/8” BSP 30 30 1/8” BSP PRESSURE/ VACUUM GAUGE 12 Ø 40 SYMBOL CODE SCALE 0 ÷1,4 bar (0 ÷20 psi) green sector R7 1,4÷5 bar (20 ÷72,5 psi) red sector Housing in black ABS material N.B. Multipurpose product: this gauge can also be used as vacuum gauge on suction filters. PRESSURE GAUGE SYMBOL CODE SCALE 0 ÷1 bar (0 ÷14,5 psi) green sector R9 1 ÷1,5 bar (14,5 ÷22 psi) yellow sector 1,5÷4 bar (22 ÷58 psi) red sector Housing in black ABS material CODE SYMBOL SCALE 0 ÷1 bar (0 ÷14,5 psi) green sector R10 1 ÷1,5 bar (14,5 ÷22 psi) yellow sector 1,5÷4 bar (22 ÷58 psi) red sector Housing in black ABS material Preferential option FR-1 series 9 User Tips INDICATOR PORT FILLING PLUG FILTER HEAD SPARE SEAL KIT PART NUMBER NBR FKM FR-1-10/11 06.021.00170 06.021.00174 FR-1-20/22/30/31 06.021.00171 06.021.00175 06.021.00172 06.021.00176 FR-1-40/43 FR-1-50/51/60/64 06.021.00173 06.021.00177 IN FILTER BOWL FILTER ELEMENT M6 M8 M10 FIXING BOLTS TIGHTENING TORQUE 10 Nm 25 Nm 50 Nm OUT Installation Maintenance Make sure that the filter flange is well secured on the tank lid through the fixing holes and that the hose is properly connected to the IN port; verify that the OUT port is clear (in this port an extension tube can be fitted, so that the outlet is below the oil level). After mounting verify that no tension is present on the filter. Make sure that enough space is available for filter element replacement and that the clogging indicator is in a easily viewable position. If an electrical indicator is used, make sure that it is properly wired. We recommend the stocking of a spare FILTREC filter element for timely replacement when required. Before removing the top cover, ensure that the system is switched off and there is no residual pressure in the filter.Unscrew the fixing bolts of the top cover and remove it . Remove the spring first and then the dirty filter element pulling it carefully . Clean the bowl and fit a new FILTREC element, verifying the part number, particularly concerning the micron rating. When fitting the new element, open the plastic protection on the top and insert the element over the spigot in the filter bowl, then remove completely the plastic protection. Check the top cover gasket conditions and replace if necessary; put the spring in its position over the filter element and then mount the top cover and fix it screwing the fixing bolts. N.B. The used filter elements cannot be cleaned and re-used. Operation PED Compliance Make sure that the filter works within the conditions of pressure, temperature and fluid compatibility given in the first page of this data sheet. The filter element must be replaced as soon as the clogging indicator signals at working temperature (in cold start conditions, oil temperature lower than 30°C, a false alarm can be given due to oil viscosity). If no clogging indicator is mounted, make sure that the cartridge is replaced according to the system manufacturer’s recommendations. FR-1 filters conform to PED 97/23/CE norm, article 3 section 3, and so they can be used with fluids of group 2 ( liquids with steam pressure < 0,5 bar at the maximum allowable temperature, article 3, section 1.1(b) – sub-section II). WARNING Make sure that Personal Protective Equipment (PPE) is worn during installation and maintenance operation. Disposal of filter elements The used filter elements and the filter parts dirty of oil are classified as “Dangerous waste material”: they must be disposed according to the local laws by authorized Companies. FR-1 series 10 CT10-rev.01-09/15 FR-1 series w w w. f i l t r e c . c o m Technical information may change without notice
Similar documents
FA-1 series
Housing in black ABS material N.B. Multipurpose product: this gauge can also be used as vacuum gauge on suction filters.
More informationF420-D1 series
The differential clogging indicator registers the pressure upstream and downstream the filter element and activates a signal when the differential pressure reaches the set value: •in the VISUAL ind...
More information