Telescopic pillars PDF DOCUMENT

Transcription

Telescopic pillars PDF DOCUMENT
Telemag TGC
Telescopic pillars AC versions
Dimensional drawing
PAM-1-130256
†6,5
,3
†15
59
14
Connecting diagrams
Electric L
N
PE
,3
59
10
59
0
0
,3
†15
min. 10
76
Retracted length ±2
Telemag TGC
†6,5
0
12
Stroke ±2
*Integrated control unit
12
0
0
10
0
,3
59
min. 10
TGC pneumatic*
Hand switch
Foot switch
Desk switch
12
0
12
Stroke ±2
PFP 1K
Telescopic pillar
PFP 1
PHC
0
14
76
85
4xM5x15
Retracted length ±2
Suitable control units and accessories
4xM5x15
85
97
2xT6,3 A max
Benefits
L1
… Push or pull load
LS
L2
N
Supporting
plate
Label position
Supporting
plate
PE
4xM6x22
4xM5x20
… Compact design
12
0
14
0
12
… Quiet
Pneumatic
72
72
0
12
0
86
86
10
0
0
†24,5
†24,5
min. 10
2xT6,3 A max
… Plug and play
PE
N
min. 10
†6,5
†6,5
L1
2-section
Standards
3-section
Note: mounting plates are not included.
To be ordered separately.
Legend:
S = stroke
L = retracted length
LS
… EN/IEC 60601–1
12
0
14
0
10
L
N
PE
… Robust
Label position
L3
… UL 60601–1
Technical data
Rated push load
Rated pull load
Bending load
Speed (full load to no load)
Telescopic pillar version
Stroke
Retracted length (push version)
Retracted length (pull version)
Voltage
Power
Current
Duty cycle: intermittent operation
Duty cycle: short-time operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight
* For details, please see bending load diagrams
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
120 V AC
230 V AC
120 V AC
230 V AC
120 V AC
230 V AC
120 V AC
230 V AC
120 V AC
230 V AC
Unit
TGC 8AWAS
TGC 8AWAK
TGC 8AWDS
TGC 8AWDK
N
N
Nm
mm/s
mm/s
# of section
mm
mm
mm
V AC
W
W
A
A
min.
min.
min.
min.
°C
IP
–
–
kg
1 000
1 000
up to 130*
11 to 12
9 to 10
2-section
200 to 700
S + 145
S + 150
120 or 230
300
210
2,5
0,95
0,8 min./21 min.
1 min./19 min.
1,5
2
+10 to +40
20/30
I
electrical
4,5 to 7,5
1 000
1 000
up to 130*
11 to 12
9 to 10
2-section
200 to 700
S + 145
S + 150
120 or 230
300
210
2,5
0,95
0,8 min./21 min.
1 min./19 min.
1,5
2
+10 to +40
20/30
I
pneumatic
4,5 to 7,5
1 000
1 000
up to 450*
11 to 12
9 to 10
3-section
300 to 700
S + 45
S + 50
120 or 230
300
210
2,5
0,95
0,8 min./21 min.
1 min./19 min.
1,5
2
+10 to +40
20/30
I
electrical
5,9 to 9,5
1 000
1 000
up to 450*
11 to 12
9 to 10
3-section
300 to 700
S + 45
S + 50
120 or 230
300
210
2,5
0,95
0,8 min./21 min.
1 min./19 min.
1,5
2
+10 to +40
20/30
I
pneumatic
5,9 to 9,5
Telescopic pillars AC versions
Telemag TGC
Telemag TGC
Ordering key
Performance diagram
Speed (mm/s)
40
T G C 8 A W
30
–
0
Type
Tube set:
Tube set 2™
Tube set 3™
20
A
D
Control:
Electrical control
Pneumatic control
Low-voltage control
10
0
0
1 000
2 000
3 000
4 000
Voltage:
230 V AC/50 Hz, IP 30 (no code)
120 V AC/60 Hz, IP 20
Special voltage
Load (N)
120 V AC version
230 V AC version
Speed-load diagram
2
9
Type of protection /test:
Standard IP30 (no code)
UL test
Bending load diagrams
1 000
Overload range
Overload range
800
800
600
600
Ideal range
400
200
Underload range
0
1
3
Stroke (S):
200 mm (only for tube set 2™)
300 mm
400 mm
500 mm
600 mm
700 mm
Stroke
700
600
500
400
300
Ideal range
400
U
Construction:
Push load
Customer-specific
Pull load
Load (N)
Load (N)
1 000
200
S
K
N
2
3
4
5
6
7
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
Underload range
0
0
0
50
100
150
200
250
Load distance from center of pillar (mm)
Bending load diagram 2-section
0
100 200
300
400
500
600
700
800
Load distance from center of pillar (mm)
Accessories
Bending load diagram 3-section
Top mounting plate for 2 ™ tube set
Bottom mounting plate for 2 ™ tube set
Top mounting plate for 3 ™ tube set
Bottom mounting plate for 3 ™ tube set
Screw (4/plate), only for 2 ™ tube set, bottom plate
Screw (4/plate), only for 3 ™ tube set, bottom plate
Lock washer (4/plate)
Plug AC Telemag 3–pin
Plug AC Telemag 5–pin
Safety factor load conditions
Safety factor
20
Designation
Order N°
SPL–964280
SPL–964281
SPL–964280
SPL–965121
ZBE–510751
ZBE–510709
ZBE–510024
SEL–265518
SEL–265519
M/0125629
M/0125630
M/0125629
M/0125631
M/0125368
M/0125560
M/0125339
M/0124866
M/0124864
18
16
14
12
M9x1,25
10
8
6
*)
4
2
® SKF is a registered trademark of the SKF Group
0
0
200
400
600
800
© SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
1 000
Stroke (mm)
* Safety factor = 4
Printed in Sweden on environmentally friendly paper.
PUB L5322,1610 EN · February 2011
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Telemag THC
Telescopic pillars AC versions
Suitable control units and accessories
Dimensional drawing
0
18
0
PAM-1-130256
PFP 1K
Telescopic pillar
PFP 1
PHC
16
86
86
15
13
0
10
†8,5
†20
†22
†15
min. 10
15
0
18
0
0
S
THC pneumatic*
Hand switch
Foot switch
Desk switch
Stroke ±2
*Integrated control unit
97
97
Telemag THC
3
11
4xM6x20
Connecting diagrams
Electric L
2xT6,3 A max
Benefits
L1
LS
L2
PE
N
11
L
PE
… Push or pull load
3
Retracted length ±2
N
L3
Label position
Supporting plate
… Quiet
4xM6x25
Pneumatic
L
N
PE
… Robust
0
16 ,5
2
10
min. 10
2xT6,3 A max
… Plug and play
PE
N
15
0
15
13 0
0
2,5
0
18
… Powerful
0
18
10
10
†20,5
†8,5
L1
2-section
Standards
3-section
Note: mounting plates are not included.
To be ordered separately.
Legend:
S = stroke
L = retracted length
LS
… EN/IEC 60601–1
9
12
… UL 60601–1
Technical data
Rated push load
Rated pull load
Bending load
Speed (full load to no load)
Telescopic pillar version
Stroke
Retracted length (push version)
Retracted length (pull version)
Voltage
Power
Current
Duty cycle: intermittent operation
Duty cycle: short-time operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight
* For details, please see bending load diagrams
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
120 V AC
230 V AC
120 V AC
230 V AC
120 V AC
230 V AC
120 V AC
230 V AC
120 V AC
230 V AC
Unit
THC 8AWAS
THC 8AWAK
THC 8AWDS
THC 8AWDK
N
N
Nm
mm/s
mm/s
# of section
mm
mm
mm
V AC
W
W
A
A
min.
min.
min.
min.
°C
IP
–
–
kg
1 800
1 800
up to 250*
15 to 20
12 to 17
2-section
200 to 700
S+155
S+160
120 or 230
720
500
6
2,2
0,7 min./30 min.
1 min./27 min.
1
2
+10 to +40
20/30
I
electrical
7,9 to 13,5
1 800
1 800
up to 250*
15 to 20
12 to 17
2-section
200 to 700
S+155
S+160
120 or 230
720
500
6
2,2
0,7 min./30 min.
1 min./27 min.
1
2
+10 to +40
20/30
I
pneumatic
7,9 to 13,5
1 800
1 800
up to 900*
15 to 20
12 to 17
3-section
230 to 700
S+60
S+65
120 or 230
720
500
6
2,2
0,7 min./30 min.
1 min./27 min.
1
2
+10 to +40
20/30
I
electrical
8,6 to 17,5
1 800
1 800
up to 900*
15 to 20
12 to 17
3-section
230 to 700
S+60
S+65
120 or 230
720
500
6
2,2
0,7 min./30 min.
1 min./27 min.
1
2
+10 to +40
20/30
I
pneumatic
8,6 to 17,5
Telescopic pillars AC versions
Telemag THC
Telemag THC
Ordering key
Performance diagram
Speed (mm/s)
40
TH C 8
W
–
0
30
Type
Load:
1 800 N
1 500 N
1 300 N
20
A
B
C
10
Tube set:
Tube set 2™
Tube set 3™
0
0
1 000
2 000
3 000
Load (N)
Control:
Electrical control
Pneumatic control
Low-voltage control
120 V AC version
230 V AC version
Speed-load diagram
A
D
4 000
S
K
N
Voltage:
230 V AC/50 Hz, IP 30 (no code)
120 V AC/60 Hz, IP 20
Special voltage
Bending load diagrams
Load (N)
2
9
Type of protection /test:
Standard IP30 (no code)
UL test
Load (N)
U
2 000
2 000
Construction:
Push load
Customer-specific
Pull load
Overload range
Overload range
1 500
1 500
Stroke
0
1
3
700
Stroke (S):
200 mm (only for tube set 2™)
300 mm
400 mm
500 mm
600 mm
700 mm
1 000
1 000
Ideal range
Ideal range
600
500
400
500
500
300
Underload range
Underload range
0
0
0
50
100
150
200
250
300
Load distance from center of pillar (mm)
0
200
400
600
800
1 000
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
Load distance from center of pillar (mm)
Bending load diagram 3-section
Bending load diagram 2-section
Safety factor load conditions
Accessories
Top mounting plate for 2 ™ tube set
Bottom mounting plate for 2 ™ tube set
Top mounting plate for 3 ™ tube set
Bottom mounting plate for 3 ™ tube set
Screw (4/plate) for top mounting plate
Screw (4/plate) for bottom mounting plate
Plug AC Telemag 3 pin
Plug AC Telemag 5 pin
Safety factor
20
18
16
14
12
2
3
4
5
6
7
Tr 12,5 x 1,6
10
Designation
Order N°
SPL–264265
SMT–264363
SPL–264265
SPL–264237
ZBE–510671
ZBE–510709
SEL–265518
SEL–265519
M/0125688
M/0124814
M/0125688
M/0125622
M/0125628
M/0125560
M/0124866
M/0124864
8
6
*)
4
2
® SKF is a registered trademark of the SKF Group
0
0
200
400
600
800
© SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
1 000
Stroke (mm)
* Safety factor = 4
Printed in Sweden on environmentally friendly paper.
PUB L5322,1620 EN · May 2010
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Telemag THG
Telescopic pillars DC versions
Suitable control units and accessories
Dimensional drawing
Telescopic pillar
MCU
BCU 8
BCU 5
VCU 9
VCU 8
VCU 5
SCU 9
SCU 5
SCU 1
Control units
8,5
180
160
THG
EHA 1
15
0
18
0
13
15
0
0
86
86
10
10
EHA 3
22
STF
20
STJ
Stroke ±2
STA
STE
Hand switch
Foot switch
Desk switch
20
S
Telemag THG
20
97
97
3
11
Retracted length ±2
Connecting diagram*
… Compact design
… Robust
113
24 V DC
+
5V+
Standards
4xM6/25
9Nm
GND
1,5K
… EN/IEC 60601–1
DIN8 plug
… UL 60601–1
9
12
L
Benefits
4xM6/25
9Nm
1+7
1,5K
15
0
Hall A
Hall B
180
0
16
2,5
10
3 5 6 8
2+4
13
15
0
0
0
18
10
2,5
10
Blue
Red
10
20,5
M
8,5
2 Hallsensors signal
2-section
3-section
Actuator
* Only valid with THG11. THG10 must be operated by a
BCU, SCU or VCU control unit.
Legend:
S = stroke
L = retracted length
Note: mounting plates are not included.
To be ordered separately.
Technical data
Rated push load
Rated pull load
Bending load
Speed (full load to no load)
Telescopic pillar version
Stroke
Retracted length
Voltage
Power
Current
Duty cycle: intermittent operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight
* for details, please see bending load diagrams
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
Unit
THG 10/11–BA
THG 10/11–CA
THG 10/11–BD
THG 10/11–CD
N
N
Nm
mm/s
# of section
mm
mm
V DC
W
A
min.
°C
IP
–
–
kg
2 000
0
up to 250*
5 to 7
2-section
200 to 700
S+270
24
120
5
1 min./9 min.
+10 to +40
30
SELV
electrical
8 to 14
1 000
0
up to 120*
12 to 15
2-section
200 to 700
S+270
24
120
5
1 min./9 min
+10 to +40
30
SELV
electrical
8 to 14
2 000
0
up to 1 000*
5 to 7
3-section
200 to 700
S+180
24
120
5
1 min./9 min
+10 to +40
30
SELV
electrical
8 to 14
1 000
0
up to 450*
12 to 15
3-section
200 to 700
S+180
24
120
5
1 min./9 min
+10 to +40
30
SELV
electrical
8 to 14
Telescopic pillars DC versions
Telemag THG
Telemag THG
Ordering key
Performance diagrams
Speed (mm/s)
Current consumtion (A)
16
12
THG 1
–
– 0 0 0
C
12
9
8
6
Type
B
4
3
0
0
0
500
1 000
1 500
2 000
Voltage:
24 V DC
24 V DC with integrated current cut-off
B
C
Load:
2 000 N
1 000 N
0
500
1 000
1 500
Load (N)
Stroke (S):
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm
Load (N)
Load (N)
Overload range
Overload range
Overload range
800
1 500
1 500
Stroke
700
1 000
Ideal
range
600
Ideal
range
500
Stroke
700
600
600
400
500
300
Underload range
300
200
400
600
800
1 000
Bending load diagram THG...BD
Ideal range
200
THG...CA
Underload range
Underload range
0
0
Load distance from center of pillar (mm)
500
0
100
200
300
400
500
600
700
800
Load distance from center of pillar (mm)
Bending load diagram THG...CD
0
50
100
150
200
250
1
2
A
3
4
B
Option:
No option
1-Hall encoder, 8 pulses, cable with jack plug
Potentiometer, 1 kΩ, 2 Watt, 0,25 % linearity, 10 turns (tube set 3™ only)
Cable feedthrough, 5 ™ 0,75 mm2, top +160 mm, bottom +800 mm
Cable feedthrough, 1-Hall encoder
Cable feedthrough, potentiometer (tube set 3™ only)
2-Hall encoder, cable with DIN8 plug
Cable feedthrough, 2-Hall encoder, cable with DIN8 plug
THG...BA
400
200
0
Ideal range
1 000
500
400
2
3
4
5
6
7
Cable / connecting plug:
Straight, 1,0 m / jack plug
Straight, 2,3 m / jack plug
Coiled, 0,6 m / jack plug
Straight, 1,0 m / DIN8 plug
Straight, 2,3 m / DIN8 plug
Coiled, 0,6 m / DIN8 plug
Load (N)
2 000
1 000
2 000
200
A
D
Current-load diagram
Bending load diagrams
0
B
C
Tube set:
Tube set 2™
Tube set 3™
2 000
Load (N)
Speed-load diagram
0
1
300
Load distance from center of pillar (mm)
0
A
B
C
D
E
F
G
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
Bending load diagram THG...BA/CA
Safety factor load conditions
Accessories
Safety factor
Top mounting plate for 2 ™ tube set
Bottom mounting plate for 2 ™ tube set
Top mounting plate for 3 ™ tube set
Bottom mounting plate for 3 ¥ tube set
Screw (4/plate) for mounting plate (2 tube set)
Screw (4/plate) for mounting plate (3 tube set)
24
18
B/Tr 15x5
Designation
Order N°
SPL–264265
SMT–264363
SPL–264265
SPL–264237
ZBE–510709
ZBE–510707
M/0125688
M/0124814
M/0125688
M/0125622
M/0125560
M/0125360
12
6
*)
C/Tr 12,5x10
® SKF is a registered trademark of the SKF Group
0
0
250
500
750
© SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
1 000
Stroke (mm)
* Safety factor = 4
Printed in Sweden on environmentally friendly paper.
PUB L5322,1650 EN · May 2010
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Telemag TLC
Telescopic pillars AC versions
Suitable control units and accessories
Dimensional drawing
PAM-1-130256
PFP 1K
Telescopic pillar
PFP 1
PHC
22
0
0
19
10
1
1
10
20
0
17
0
0
22
15
†11
15
†20
†22
S
TLC pneumatic*
Hand switch
Foot switch
Desk switch
Stroke ±2
*Integrated control unit
9
12
9
12
Telemag TLC
4xM10x30
Retracted length ±2
Electric L
N
PE
2xT6,3 A max
6
14
6
14
L
Connecting diagrams
Benefits
20
0
3
16
Label position
L1
… Push or pull load
L2
PE
N
L3
Supporting plate
4xM10x30
LS
… High bending load
22
20
0
0
… Quiet
Pneumatic
9
12
L
15
0
†11
†22
2xT6,3 A max
… Plug and play
PE
N
L1
2-section
Standards
3-section
Note: mounting plates are not included.
To be ordered separately.
Legend:
S = stroke
L = retracted length
LS
… EN/IEC 60601–1
20
15
N
PE
… Powerful
0
22
17
0
12
9
0
19
… UL 60601–1
Technical data
Rated push load
Rated pull load
Bending load
Speed (full load to no load)
Telescopic pillar version
Stroke
Retracted length (push version)
Retracted length (pull version)
Voltage
Power
Current
Duty cycle: intermittent operation
Duty cycle: short-time operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight
* For details, please see bending load diagrams
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
120 V AC
230 V AC
120 V AC
230 V AC
120 V AC
230 V AC
120 V AC
230 V AC
120 V AC
230 V AC
Unit
TLC 12ZWAS
TLC 12ZWAK
TLC 12ZWDS
TLC 12ZWDK
N
N
Nm
mm/s
mm/s
# of section
mm
mm
mm
V AC
W
W
A
A
min.
min.
min.
min.
°C
IP
–
–
kg
4 000
4 000
up to 630*
15 to 22
11 to 17
2-section
100 to 700
S+175
S+185
120 or 230
1 200
890
10
4,1
0,8 min./37 min.
1 min./37 min.
1,2
2
+10 to +40
20/30
I
electrical
15,2-24,5
4 000
4 000
up to 630*
15 to 22
11 to 17
2-section
100 to 700
S+175
S+185
120 or 230
1 200
890
10
4,1
0,8 min./37 min.
1 min./37 min.
1,2
2
+10 to +40
20/30
I
pneumatic
15,2-24,5
4 000
4 000
up to 2 100*
15 to 22
11 to 17
3-section
255 to 700
S+60
S+70
120 or 230
1 200
890
10
4,1
0,8 min./37 min.
1 min./37 min.
1,2
2
+10 to +40
20/30
I
electrical
18,3-30,5
4 000
4 000
up to 2 100*
15 to 22
11 to 17
3-section
255 to 700
S+60
S+70
120 or 230
1 200
890
10
4,1
0,8 min./37 min.
1 min./37 min.
1,2
2
+10 to +40
20/30
I
pneumatic
18,3-30,5
Telescopic pillars AC versions
Telemag TLC
Telemag TLC
Ordering key
Performance diagram
Speed (mm/s)
40
T L C 12
30
W
–
0
Type
Load:
4 000 N
3 000 N
2 000 N
20
Z
X
S
10
Tube set:
Tube set 2™
Tube set 3™
0
0
1 000
2 000
3 000
Control:
Electrical control
Pneumatic control
Low-voltage control
Load (N)
120 V AC version
230 V AC version
Speed-load diagram
A
D
4 000
S
K
N
Voltage:
230 V AC/50 Hz (no code)
120 V AC/60 Hz
Special voltage
Bending load diagrams
Load (N)
Type of protection/test:
Standard IP30 (no code)
UL approved
Load (N)
4 000
2
9
U
4 000
Overload range
Construction:
Push load
Customer-specific
Pull load
Overload range
3 000
3 000
0
1
3
Stroke
2 000
Stroke (S):
100 mm, only for tube set 2™, push
255 mm, only for tube set 3™, push
200 mm, only for tube set 2™
300 mm
400 mm
500 mm
600 mm
700 mm
700
2 000
Ideal range
Ideal range
600
500
1 000
1 000
400
300
Underload range
0
0
100
200
300
Underload range
0
400
Load distance from center of pillar (mm)
0
200
400
600
800
1 000
Load distance from center of pillar (mm)
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
Bending load diagram 3-section
Bending load diagram 2-section
Safety factor load conditions
Accessories
Top mounting plate for 2 ™ tube set
Bottom mounting plate for 2 ™ tube set
Top mounting plate for 3 ™ tube set
Bottom mounting plate for 3 ™ tube set
Screw (4/plate) for mounting plate
Plug AC Telemag 3 pin
Plug AC Telemag 5 pin
Safety factor (screw buckling)
20
18
16
Tr 16x2,5
14
1
1
2
3
4
5
6
7
12
Designation
Order N°
SPL–290268
SPL–290351
SPL–290268
SPL–290265
ZBE–510707
SEL–265518
SEL–265519
M/0125624
M/0125625
M/0125624
M/0125623
M/0125360
M/0124866
M/0124864
10
8
6
*)
4
2
® SKF is a registered trademark of the SKF Group
0
0
200
400
600
800
© SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
1 000
Stroke (mm)
* Safety factor = 4
Printed in Sweden on environmentally friendly paper.
PUB L5322,1630 EN · February 2011
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Telemag TLG
Telescopic pillars DC versions
Suitable control units and accessories
Dimensional drawing
Telescopic pillar
MCU
BCU 8
BCU 5
VCU 9
VCU 8
VCU 5
SCU 9
SCU 5
SCU 1
Control units
†11
0
19
EHA1
EHA3
17
10
1
†20
1
10
†11
0
0
19
10
1
†20
01
1
15
17
0
0
†22
†22
STJ
20
0
22
0
15
STF
Telemag TLG
20
0
22
TLG
25
25
Hand switch
Foot switch
Desk switch
Stroke ±2
Stroke ±2
STA
STE
25
25
9
12
9
12
4 x M10/30
40 Nm
Connecting diagram*
… High bending load
… Powerful
6
14
Retracted length ±2
Retracted length ±2
4 x M10/30
40 Nm
Benefits
6
14
3
16
24 V DC
+
5V+
GND
1,5K
… EN/IEC 60601–1
DIN8 plug
… UL 60601–1
1+7
2+4
Blue
Red
M
4 x M10/30
40 Nm
4 x M10/30
40 Nm
1,5K
Hall A
Hall B
22
20
0
17
0
0
19
12
9
12
3 5 6 8
15
†22
0
20
0
22
9
17
†11
0
0
0
19
14
6
14
15
Standards
6
†22
†11
2 Hallsensors signal
2-section
3-section
Actuator
* Only valid with TLG11. TLG10 must be operated by a BCU,
MCU, SCU or VCU control unit.
Note: mounting plates are not included.
To be ordered separately.
Legend:
S = stroke
L = retracted length
Technical data
Rated push load
Rated pull load
Bending load
Speed (full load to no load)
Telescopic pillar version
Stroke
Retracted length
Voltage
Power
Current
Duty cycle: intermittent operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight
* For details, please see bending load diagrams
2
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Unit
TLG 10/11–A
TLG 10/11–B
TLG 10/11–C
N
N
Nm
mm/s
# of section
mm
mm
V DC
W
A
min.
°C
IP
–
–
kg
4 000
0
up to 2 800*
10 to 14
2 or 3-section
200 to 700
S+180
24
156
6,5
1 min./9 min
+10 to +40
30
SELV
electrical
15 to 30
2 500
0
up to 1 750*
13 to 17
2 or 3-section
200 to 700
S+180
24
156
6,5
1 min./9 min
+10 to +40
30
SELV
electrical
15 to 30
1 500
0
up to 950*
25 to 33
2 or 3-section
200 to 700
S+180
24
156
6,5
1 min./9 min
+10 to +40
30
SELV
electrical
15 to 30
Telescopic pillars DC versions
Telemag TLG
Telemag TLG
Ordering key
Performance diagrams
T L G 1
Speed (mm/s)
–
– 0 0 0
Current consumtion (A)
40
12
Type
C
30
Voltage:
24 V DC
24 V DC with integrated current cut-off
9
B
C
20
A
0
1
6
Load:
4 000 N
2 500 N
1 500 N
B
10
3
A
0
Tube set:
Tube set 2™
Tube set 3™
0
0
1 000
2 000
3 000
4 000
0
1 000
2 000
3 000
Load (N)
4 000
Load (N)
Bending load diagrams
Load (N)
2 500
Overload range
Overload range
2 000
3 000
Stroke
700
Ideal range
600
700
Ideal range
1 000
600
500
1 000
400
500
400
500
300
Underload range
300
200
0
200
Underload range
0
0
200
400
600
800
1 000 1 200 1 400
0
Load distance from center of pillar (mm)
200
400
600
800
0
A
B
C
D
E
F
G
1 000 1 200 1 400
Load distance from center of pillar (mm)
Bending load diagram TLG ...AD
1
2
A
3
4
B
Option:
No option
1-Hall encoder, 8 pulses, cable with jack plug
Potentiometer, 1 kΩ, 2 Watt, 0,25 % linearity, 10 turns
Cable feedthrough, 5 ™ 0,75 mm2, led out, top +160 mm, bottom +800 mm
Cable feedthrough, 1-Hall encoder
Cable feedthrough, potentiometer
2-Hall encoder, cable with DIN8 plug
Cable feedthrough, 2-Hall encoder, cable with DIN8 plug
1 500
Stroke
2 000
2
3
4
5
6
7
Cable / connecting plug:
Straight, 1,0 m / jack plug
Straight, 2,3 m / jack plug
Coiled, 0,6 m / jack plug
Straight, 1,0 m / DIN8 plug
Straight, 2,3 m / DIN8 plug
Coiled, 0,6 m / DIN8 plug
Load (N)
4 000
A
D
Stroke (S):
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm
Current-load diagram
Speed-load diagram
A
B
C
Options written in italic fonts are only available on demand. Please contact SKF
Bending load diagram TLG ...BD
Safety factor load conditions
Accessories
Safety factor
20
C / Tr 12,5 x 10
15
Load (N)
Load (N)
1 500
B / Tr 15 x 5
4 000
Overload range
Overload range
3 500
Stroke
700
5
2 500
2 000
500
500
1 500
400
1 000
200
0
200
400
600
800
1 000
1 200
Load distance from center of pillar (mm)
Bending load diagram TLG ...CD
SPL–290268
SPL–290351
SPL–290268
SPL–290265
ZBE–510707
M/0125624
M/0125625
M/0125624
M/0125623
M/0125360
0
0
500
250
500
750
1 000
Stroke (mm)
TLG1-AA
TLG1-BA
TLG1-CA
* Safety factor = 4
Underload range
® SKF is a registered trademark of the SKF Group
0
0
Top mounting plate for 2 ™ tube set
Bottom mounting plate for 2 ™ tube set
Top mounting plate for 3 ™ tube set
Bottom mounting plate for 3 ™ tube set
Screw (4/plate) for mounting plate
A / Kr 14 x 4
Ideal
range
300
Underload range
Order N°
*)
Ideal
range
600
Ideal range
Designation
Ideal
range
3 000
1 000
10
Description
0
50
100
150
200
250
300
350
400
© SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Load distance from center of pillar (mm)
Bending load diagram TLG...AA/BA/CA
Printed in Sweden on environmentally friendly paper.
PUB L5322,1660 EN · May 2010
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Telemag TLT
Telescopic pillars DC versions
Suitable control units and accessories
Dimensional drawing
Control units
†22
BCU 8
10
0
19 01
1
EHA3
STJ
25
29
N1
4™M10
30 mm deep
Retracted length ±4
Connecting diagram*
(without mounting plates)
Supporting
plate
… Very small built-in dimension
… Powerful
†11
25
STE
Hand switch
Foot switch
Desk switch
Benefits
20
0
0
17
1
15
TLT
Telemag TLT
†20
0
Stroke ±4
BCU 5
VCU 9
VCU 8
VCU 5
SCU 9
SCU 1
Telescopic pillar
SCU 5
22
46
N1
63
N1
24 VDC
+
5V+
Standards
4™M10
30 mm deep
GND
1,5K
… EN/IEC 60601–1
1+7
2+4
Blue
Red
1,5K
Hall A
Hall B
DIN8
plug
… UL 60601–1
1,5K
3 5 6 8
2+4
Blue
Red
Supporting
plate
Hall A
Hall B
DIN8
plug
1+7
1,5K
22
0
0
19
3 5 6 8
17
0
14
20
0
6
6
14
†22
15
M
2 Hallsensors signal
M
Actuator
2 Hallsensors signal
†11
Max. length
2 300 mm
Actuator
Legend:
S = stroke
L = retracted length
* Only valid with TLT11. TLT10 must be operated by a
BCU, SCU or VCU control unit.
Note: mounting plates are not included.
To be ordered separately.
Technical data
Rated push load
Rated pull load
Bending load
Speed (full load to no load)
Telescopic pillar version
Stroke
Retracted length
Voltage
Power
Current
Duty cycle: intermittent operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight
* For details, please see bending load diagrams
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
Unit
TLT10–A1
TLT10–A2
TLT10–B1
TLT10–C1
TLT10–C2
N
N
Nm
mm/s
# of section
mm
mm
V DC
W
A
min.
°C
IP
–
–
kg
3 000
0
up to 400*
11 to 16
3-section
300 to 700
0,5 ™ S+170
24
168
2™3,5
1 min./9 min
+10 to +40
40
SELV
electrical
15 to 30
4 000
0
up to 1 000*
13 to 19
3-section
300 to 700
0,5 ™ S+240
24
168
2™3,5
1 min./9 min
+10 to +40
40
SELV
electrical
15 to 30
2 000
0
up to 250*
13 to 19
3-section
300 to 700
0,5 ™ S+170
24
192
2™4,0
1 min./9 min
+10 to +40
40
SELV
electrical
15 to 30
1 000
0
up to 110*
25 to 36
3-section
300 to 700
0,5 ™ S+170
24
192
2™4,0
1 min./9 min
+10 to +40
40
SELV
electrical
15 to 30
2 000
0
up to 480*
25 to 42
3-section
300 to 700
0,5 ™ S+240
24
216
2™4,5
1 min./9 min
+10 to +40
40
SELV
electrical
15 to 30
Telescopic pillars DC versions
Telemag TLT
Telemag TLT
Ordering key
Performance diagrams
Speed (mm/s)
Current consumption (A)
5,0
40
T L T 1
–
– 0 0 0
4,5
36
32
4,0
C1
B1
28
3,5
24
3,0
C1
Type
A1
Voltage:
24 V DC
24 V DC with integrated current cut-off (only for A2 and C2)
2,5
20
B1
16
2,0
A1
12
1,5
8
1,0
4
0,5
Load / Speed:
4 000 N
3 000 N
2 000 N / 19 to 13 mm/s
2 000 N / 42 to 25 mm/s
1 000 N
0
0
1 000
2 000
3 000
0
4 000
1 000
2 000
3 000
4 000
Load (N)
Load (N)
Speed-load diagram
5,0
45
4,5
40
4,0
35
C2
3,5
C2
3,0
25
2,5
20
2,0
A2
15
1,5
10
1,0
5
0
A
C
D
F
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
0,5
0
1
2
A
3
4
B
Option:
No option
1-Hall encoder, 8 pulses, cable with jack plug
Cable feedthrough, 3x1,5 mm2, top +160 mm, bottom +800 mm
Cable feedthrough, 1-Hall encoder
2-Hall encoder, cable with DIN8 plug
A2
30
3
4
5
6
7
Cable / connecting plug:
Straight, 1,0 m / jack plug
Straight, 2,3 m / jack plug
Coiled, 0,6 m / jack plug
Straight, 1,0 m / DIN8 plug
Straight, 2,3 m / DIN8 plug
Coiled, 0,6 m / DIN8 plug
Current consumption (A)
50
A2
A1
B1
C2
C1
Stroke (S):
300 mm
400 mm
500 mm
600 mm*
700 mm*
Current-load diagram
Speed (mm/s)
0
1
0
0
1 000
2 000
3 000
4 000
0
1 000
2 000
3 000
4 000
Load (N)
Load (N)
Speed-load diagram
Current-load diagram
* Reduced safety factor
Bending load diagrams
Accessories
Load (N)
Top mounting plate
Bottom mounting plate
Screw (4/plate) for mounting plate
4 000
Overload range
Overload range
3 500
2 600
Ideal
range
2 200
M/0125624
M/0125623
M/0125360
Ideal
range
2 500
1 800
1 600
2 000
Ideal
range
1 200
SPL–290268
SPL–290265
ZBE–510707
3 000
2 000
1 400
Order N°
Load (N)
3 000
2 800
2 400
Designation
TLT1 A-1
TLT1 A-2
1 500
1 000
800
600
TLT1 B-1
Ideal
range
400
TLT1 C-2
500
200
Underload range
0
0
Ideal
range
1 000
50
100
150
200
250
TLT1 C-1
300
Load distance from center of pillar (mm)
Bending load diagram A1, B1, C1
Underload range
0
0
100
200
300
400
® SKF is a registered trademark of the SKF Group
© SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
500
Load distance from center of pillar (mm)
Bending load diagram A2, C2
Printed in Sweden on environmentally friendly paper.
PUB L5322,1670 EN · February 2011
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Telemag TFG
Telescopic pillars
Suitable control units and accessories
Dimensional drawing
Control units
72 17
TFG 90
Integrated control unit
0
11
N
EHA3
STJ
STE
1xM
35 N 10/16
m
LD-034.000.004
Retracted length = stroke +130 mm
LD-011.031.000
Hand switch
Foot switch
Desk switch
Benefits
Connecting diagrams
… Compact design
… Fast movement
25
4xM6/
9 Nm
3
13
N
PE
1,5K
DIN8 plug
Standards
… EN/IEC 60601–1
Limit switches
… UL 60601–1
1+7
2+4
Blue
Red
1,5K
Operating
device
Hall A
Hall B
3 5 6 8
2 Hallsensors signal
M
Actuator
Note: mounting plates are not included.
To be ordered separately.
%
&
Option
&
M
Legend:
S = stroke
L = retracted length
Technical data
Rated push load
Rated pull load
Bending load
Speed (full load to no load)
Telescopic pillar version
Stroke
Retracted length
Voltage
Power
Current
Duty cycle: intermittent operation
Duty cycle: short-time operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight
* For details, please see bending load diagrams
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
0
13
5
/2
M6
4x Nm
9
N
GND
… Plug and play
N10
2,5
196
120/230 V AC
L
24 V DC
+
5V+
… Powerful
Electro Mechanical Systems Limited
1
12
10
… Push or pull load
N
250
Telemag TFG
7
20 2
Stroke
Telescopic pillar
Integrated control unit
180
160
72
4x†8,
5
TFG 10
TFG 50
20
Min. 10
STE
STJ
EHA3
LD 015
LD 014
BCU 8
BCU 5
VCU 9
VCU 8
VCU 5
SCU 9
SCU 5
SCU 1
0
15 130 2
7 17
Unit
TFG 10
TFG 50
TFG 90
N
N
Nm
mm/s
# of section
mm
mm
V AC
W
A
min.
min.
°C
IP
–
–
kg
2 500
2 500
up to 500*
15 to 19
3-section
200 to 700
S+130
24
120
5
1 min./9 min.
3
+10 to +40
30
SELV
electrical
8 to 19
2 500
2 500
up to 500*
15 to 19
3-section
200 to 700
S+130
120
160
1,8
1 min./9 min.
3
+10 to +40
30
1
electrical
8 to 19
2 500
2 500
up to 500*
15 to 19
3-section
200 to 700
S+130
230
160
1
1 min./9 min.
3
+10 to +40
30
1
electrical
8 to 19
Telescopic pillars
Telemag TFG
Telemag TFG
Ordering key
Performance diagrams
Speed (mm/s)
Current consumption (A)
20
T F G
0 – 2 3
– 0 0 0
6
19
5
Type
18
4
17
16
Voltage:
24 V DC
120 V AC (50/60 Hz)
230 V AC (50 Hz)
3
15
2
1
5
9
14
Stroke (S):
200 mm
250 mm
300 mm
350 mm
400 mm
500 mm
700 mm
1
13
12
0
500
0
1 000
1 500
2 000
2 500
0
500
1 000
1 500
2 000
Load (N)
2 500
Load (N)
Speed-load diagram
Current-load diagram
TFG 10
TFG 50
TFG 90
200
250
300
350
400
500
700
Option:
No option
With 2-Hall encoder, 14 pulses per 9 mm travel
With mains cable feedthrough (3xAWG16)
With control cable feedthrough (10xAWG28)
000
E
C
H
Bending load diagrams
Load (N)
Load (N)
Load (N)
2 500
2 500
2 500
2 000
2 000
2 000
Accessories
1 500
1 500
1 500
Top mounting plate Bore 72 ™ 72 mm
Bottom mounting plate Bore 102,5 ™ 102,5 mm
Screw for top mounting plate M10 ™ 25 (1 screw required)
Screw for top mounting plate M6 ™ 30 (4 screws required)
Screw for bottom mounting plate M6 ™ 30 (4 screws required)
Mains cable SEV plug 3 000 mm, black, 3 ™ 0.75 mm2
Mains cable Schuko plug 3 000 mm, black, 3 ™ 0.75 mm2
Mains cable US plug 3 000 mm, black, 3 ™ 0.75 mm2
Mains cable British Standard plug 3 000 mm, black, 3 ™ 0.75 mm2
Ideal
load
Ideal
load
1 000
1 000
1 000
Slipstickarea
Slipstickarea
Ideal
load
500
500
500
Ideal
load
0
0
0
200
400
600
800
0
0
1 000
Load distance from center of pillar (mm)
200
400
600
800
1 000
Overload
Ideal
load
1 000
500
Ideal
load
0
600
800
1 000
Load distance from center of pillar (mm)
500 mm stroke
1 000
Ideal
load
1 000
500
Ideal
load
Ideal
load
® SKF is a registered trademark of the SKF Group
0
0
400
800
Overload
Ideal
load
500
600
1 500
1 500
200
400
2 000
2 000
1 000
M/0124808
M/0124814
M/0125359
M/0125560
M/0125560
M/0125331
M/0121729
M/0121762
M/0121755
Load (N)
Overload
1 500
SMT–333360
SMT–264363
ZBE–510978
ZBE–510709
ZBE–510709
ZKA–304345
ZKA–304346–3000
ZKA–304347–3000
ZKA–304355–3000
2 500
2 500
2 000
Order N°
400 mm stroke
Load (N)
Load (N)
200
Load distance from center of pillar (mm)
300 mm stroke
2 500
0
0
Load distance from center of pillar (mm)
200 mm stroke
Designation
Overload
Overload
Overload
0
200
400
600
800
1 000
Load distance from center of pillar (mm)
600 mm stroke
0
200
400
600
800
© SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
1 000
Load distance from center of pillar (mm)
700 mm stroke
Printed in Sweden on environmentally friendly paper.
PUB L5322,1675 EN · August 2010
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Telesmart TXG
Telescopic pillars
Suitable control units and accessories
Dimensional drawing
Control units
STA*
STF*
EHE1
LD 015
LD 014
BCU 8
BCU 5
VCU 9
VCU 8
VCU 5
0
15
0
12
55
14
0
12
0
10
†9
TXG 1
TXG 4 Integrated control unit
14
0
Stroke ±2
TXG 5 Integrated control unit
Telescopic pillar
19
0
TXG 8 Integrated control unit
TXG 9 Integrated control unit
18
0
Supporting
plate
EHA3
R 300
STJ
Telesmart TXG
4¥M6¥40 DIN 7 500
included
Benefits
* only with FCC plug
Retracted length ±2
LD-011.031.000
Hand switch
Foot switch
Desk switch
(without mounting plates)
STE
LD-034.000.004
12
0
Connecting diagrams
… Powerful and fast lifting
Supporting
plate
0
15
0
12
… Aesthetic design
120/230 V AC
L
24 V DC
+
Standards
4¥M6¥40 DIN 7 500
included
19
0
10
N
… EN/IEC 60601–1
22
0
17
0
85
†9
PE
… UL 60601–1
Black
Red
Note: mounting plates are not included.
To be ordered separately.
Limit switches
M
Actuator
M
Legend:
S = stroke
L = retracted length
Technical data
Rated push load
Rated pull load
Bending load
Speed (full load to no load)
Telescopic pillar version
Stroke
Retracted length
Voltage
Power
Current
Duty cycle: intermittent operation
Duty cycle: short-time operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight
1) For
details, see bending load diagrams
for cable feedthrough option
2) Mandatory
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
Unit
TXG1
TXG4/5
TXG8/9
N
N
Nm
mm/s
# of section
mm
mm
V AC
W
A
min.
min.
°C
IP
–
–
kg
1 500
0
up to 2101)
17 to 23
2-section
200 to 600
S+180
24
–
5
1 min./9 min.
–
+10 to +40
30
SELV
electrical
8 to 13
1 500
0
up to 2101)
17 to 23
2-section
200 to 600
S+180
120
N/A
1,8
1 min./9 min.
N/A
+10 to +40
30
II/(I)2)
electrical
9 to 14
1 500
0
up to 2101)
17 to 23
2-section
200 to 600
S+180
230
N/A
0,9
1 min./9 min.
N/A
+10 to +40
30
II/(I)2)
electrical
9 to 14
Telescopic pillars
Telesmart TXG
Telesmart TXG
Ordering key
Performance diagram
Speed (mm/s)
25
T X G
0 – 0 0
–
0 0
20
Type
15
Voltage:
24 V DC (slave actuator)
120 V AC, 50/60 Hz, class II
120 V AC, 50/60 Hz, class I (mandatory for cable feedthrough option)
230 V AC, 50 Hz, class II
230 V AC, 50 Hz, class I (mandatory for cable feedthrough option)
10
5
0
0
500
1 000
1
4
5
8
9
Color:
Natural anodized coating
Customer-specific
Powder-coated white
Powder-coated grey
1 500
Load (N)
Speed-load diagram
5
K
2
3
Option:
None
Control connection feedthrough
Mains cable feedthrough
Control connection feedthrough, mains cable feedthrough
Customer-specific
Bending load diagram
000
EYX
EYF
2AA
KKK
Stroke (S) / Retr. length (L=S+180 or L= S+160 mm)
200 mm
300 mm
400 mm
500 mm
600 mm
Load (N)
1 600
1 400
L=S+180
200
300
400
500
600
L=S+160
4CY
4DY
4EY
4FY
4GY
Overload range
1 200
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
1 000
800
Ideal range
600
400
Underload range
200
Accessories
0
0
75
150
225
300
Load distance from center of pillar (mm)
Safety factor load conditions
Mains cable
Plug
Country
Order number
Comment
Straight cable 3,5
Straight cable 3,5
Straight cable 3,5
Straight cable 3,5
Euro
Schuko
UL
British standard
General
General
USA
UK
M/0121730
M/0121760
M/0121757
M/0121761
2-pole
3-pole
2-pole/3-pole
2-pole/3-pole
Top or bottom mounting plate
M/0124874
Note: mounting screws are included in the TXG.
Safety factor (screw buckling)
20
15
10
5
® SKF is a registered trademark of the SKF Group
© SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
0
0
150
300
450
600
Stroke (mm)
Printed in Sweden on environmentally friendly paper.
PUB L5322,1680 EN · August 2010
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Telesmart TMA
Telescopic pillars DC versions
Suitable control units and accessories
Dimensional drawing
911
1140
49
Control units
200
117
Telescopic pillar
Telesmart TMA
30
16
LD 015
LD 014
134
TMA
LD-034.000.004
LD-011.031.000
33
Connecting diagrams
Benefits
85
… Powerful and fast lifting
TMA can only be
operated with LD
control units.
… Aesthetic design
Standards
… EN 60335
… UL 60950
60
Legend:
S = stroke
L = retracted length
Technical data
Rated push load
Rated pull load
Bending load
Speed (full load to no load)
Telescopic pillar version
Stroke
Retracted length
Voltage
Power
Current
Duty cycle: intermittent operation
Duty cycle: short-time operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight
* For details, please see bending load diagrams
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
Unit
TMA
N
N
Nm
mm/s
# of section
mm
mm
V DC
W
A
min.
min.
°C
IP
–
–
kg
1 000
0
up to 200*
35 to 55
3-section
500
640
24
168
7
1 min./9 min.
N/A
+5 to +40
20
SELV
electrical
8,5
130
484
640
621
Hand switch
Foot switch
Desk switch
Telescopic pillars DC versions
Ordering key
Performance diagrams
Lifting speed (mm/s)
Lifting speed (mm/s)
60
60
50
50
40
40
30
30
20
20
10
10
0
TMA 1 0 – 0 0
500
1 000
1 500
2 000
2 500
– 5 0 0 0 0
Type
Color:
Natural anodized coating
Black anodized coating
5
6
Options:
With flange for crossbar one side
With flange for crossbar two sides
No flange for crossbar
0
0
Telesmart TMA
Telesmart TMA
0
500
1 000
1 500
2 000
Load (N)
EWY
2CM
2CN
2 500
Load (N)
Lifting speed 3-channel control
Lifting speed 2-channel control
Lifting speed (mm/s)
Current consumption (A)
7
60
6
50
5
40
4
30
3
20
2
10
1
0
0
0
500
1 000
1 500
2 000
0
2 500
200
400
600
800
Load (N)
1 000
1 200
Accessories
Load (N)
Current-load diagram
Lifting speed 4-channel control
Cable 1,0 m with DIN8–plug
Cable 1,5 m with DIN8–plug
Cable 2,5 m with DIN8–plug
Bending load diagrams
Push load (N)
Designation
Order N°
ZKA–306355–1000
ZKA–306355–1500
ZKA–306355–2500
M/0121741
M/0121726
M/0121742
Push load (N)
1 000
1 000
900
900
800
800
Overload range
700
Overload range
700
600
600
Ideal range
Ideal range
500
500
400
400
300
300
200
200
100
100
0
0
0
100
200
300
400
500
600
0
100
200
300
400
500
600
Load arm (mm)
Load arm (mm)
® SKF is a registered trademark of the SKF Group
Dynamic stress diagram on X axis
with maximum lift*
© SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Dynamic stress diagram on Y axis
with maximum lift*
* The values given apply to single lifting pillars. With a stable table structure the ideal field of use can be enlarged.
Printed in Sweden on environmentally friendly paper.
PUB L5322,1691 EN · September 2010
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Telesmart TMD
Telescopic pillars DC versions
Suitable control units and accessories
Dimensional drawing
911
1140
49
Control units
200
117
Telescopic pillar
Telesmart TMD
30
16
LD 015
LD 014
134
TMD
LD-034.000.004
33
LD-011.031.000
621
Hand switch
Foot switch
Desk switch
85
… Powerful and fast lifting
TMD can only be
operated with LD
control units.
… Aesthetic design
… Efficient retracted length ratio
Standards
… EN 60335
60
… UL 60950
Legend:
S = stroke
L = retracted length
Technical data
Rated push load
Rated pull load
Bending load
Speed (full load to no load)
Telescopic pillar version
Stroke
Retracted length
Voltage
Power
Current
Duty cycle: intermittent operation
Duty cycle: short-time operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight
* For details, please see bending load diagrams
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
Unit
TMD
N
N
Nm
mm/s
# of section
mm
mm
V DC
W
A
min.
min.
°C
IP
–
–
kg
800
0
up to 120*
35 to 60
3-section
700
550
24
168
7
1 min./9 min.
N/A
+5 to +40
20
SELV
electrical
8,5
130
484
640
Benefits
Telescopic pillars DC versions
Ordering key
Performance diagrams
Lifting speed (mm/s)
Lifting speed (mm/s)
60
60
50
50
40
40
30
30
20
20
10
10
0
TMD 1 0 – 0 0
500
1 000
1 500
2 000
2 500
– 7 0 0 0 0
Type
Color:
Natural anodized coating
Black anodized coating
5
6
Options:
With flange for crossbar one side
With flange for crossbar two sides
No flange for crossbar
0
0
Telesmart TMD
Telesmart TMD
0
500
1 000
1 500
2 000
Load (N)
EWY
2CM
2CN
2 500
Load (N)
Lifting speed 3-channel control
Lifting speed 2-channel control
Current consumption (A)
Lifting speed (mm/s)
7
60
6
50
5
40
4
30
3
20
2
10
1
0
0
0
500
1 000
1 500
2 000
2 500
0
200
400
600
800
1 000
1 200
Load (N)
Load (N)
Accessories
Current-load diagram
Lifting speed 4-channel control
Cable 1,0 m with DIN8–plug
Cable 1,5 m with DIN8–plug
Cable 2,5 m with DIN8–plug
Bending load diagrams
Push load (N)
Designation
Order N°
ZKA–306355–1000
ZKA–306355–1500
ZKA–306355–2500
M/0121741
M/0121726
M/0121742
Push load (N)
800
800
700
700
600
600
Overload range
Overload range
500
500
Ideal range
Ideal range
400
400
300
300
200
200
100
100
0
0
0
100
200
300
400
0
Load arm (mm)
100
200
300
400
Load arm (mm)
® SKF is a registered trademark of the SKF Group
Dynamic stress diagram on X axis
with maximum lift*
© SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Dynamic stress diagram on Y axis
with maximum lift*
Printed in Sweden on environmentally friendly paper.
* The values given apply to single lifting pillars. With a stable table structure the ideal field of use can be enlarged.
PUB L5322,1692 EN · September 2010
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Telemag CPI
Telescopic pillars DC versions
Dimensional drawing
4 x M8
S
S
4 x M8
197
181,8
5
16 9,6
14
5
16 45
1
9,2
12
197
17
161,2 7
4 x M8
S
Suitable control units and accessories
40
Telescopic pillar
L=S + 150
L=S + 150
L=S + 150
80
BCU 8
BCU 5
VCU 9
VCU 8
VCU 5
SCU 9
LD
SCU 1
Telemag CPI
SCU 5
Control units
8
20
4 x M8
4 x M8
4 x M8
CPI
0,2
17
202,2
240
0,2
17 185
202,2
217
0,2 5
18
17
202,2
217
2-section
3-section
2- or 3-section with slots
EHA 3
0
8,3 +0,3
STE
8™
LD-011.031.000
Legend:
S = stroke
L = retracted length
Hand switch
Foot switch
Desk switch
… Push or pull load
Connecting diagram
… T-slotted outer tube
24 V DC
+
5V+
Standards
GND
1,5K
… EN 60950–1
Limit switches
… UL 60950–1
1+7
2+4
Blue
Red
1,5K
Hall A
Hall B
DIN8 plug
… IEC 60950–1
3 5 6 8
2 Hallsensors signal
M
Actuator
%
&
Option
&
Technical data
Max. push force
Max. pull force
Dynamic bending moment (2-section)
Dynamic bending moment (3-section)
Speed
(full load)
Speed
(no load)
Stroke
Retracted length
Voltage
Power
Current
Duty cycle: intermittent operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight (2-section)
(3-section)
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
,5
R0
(4.15)
0
16,5 +0,5
… Fast movement
… Robust and stable design
(11)
15,5±0,3
LD-034.000.004
Benefits
0
6,9 +0,4
R0,5 R0,5
Unit
CPI10-D
CPI10-E
CPI10-F
N
N
Nm
Nm
mm/s
mm/s
mm
mm
V DC
W
A
min.
°C
IP
–
–
kg
1 000
1 000
250
max. 1 000
31
38
200 to 700
S+150
24
91,2
3,8
2 min./8 min.
+10 to +40
30
III/SELV
electrical
13 to 30
14 to 34
1 500
1 500
250
max. 1 000
22
28
200 to 700
S+150
24
96
4
2 min./8 min.
+10 to +40
30
III/SELV
electrical
13 to 30
14 to 34
4 000
4 000
250
max. 1 000
11
17
200 to 700
S+150
24
144
6
1 min./9 min.
+10 to +40
30
III/SELV
electrical
13 to 30
14 to 34
0
7,5 +0,3
STJ
Telescopic pillars DC versions
Telemag CPI
Telemag CPI
Ordering key
Performance diagrams
C P I 1 0 –
T
0
– 0 0 0
Type
60
6
50
5
40
4
30
3
20
2
10
1
Voltage:
24 V DC
Load:
Push (N)
1 000
1 500
4 000
0
500
1 000 1 500 2 000
2 500 3 000 3 500 4 000
Speed-load diagram
0
500
1 000 1 500 2 000
2 500 3 000 3 500 4 000
Current-load diagram
CPI10-D
CPI10-E
CPI10-F
D
E
F
2
3
4
5
Stroke (S):
200 mm
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
550 mm
600 mm
650 mm
700 mm
Other stroke lengths
CPI10-D
CPI10-E
CPI10-F
Bending load diagrams
200
250
300
350
400
450
500
550
600
650
700
XXX
Electrical options:
None
2-Hall encoder
Lifetime monitoring
2-Hall encoder and lifetime monitoring
1 000
4 000
Speed (mm/s)
31
22
11
Tube set:
2-section
3-section
2-section T-slotted outer tube
3-section T-slotted outer tube
0
0
Pull (N)
1 000
1 500
4 000
0
F
M
N
Cable through option:
None
Mains cable feedthrough, protection class I (retracted length +30 mm) max 250 V AC, max 10 A
3 000
Special:
None
Back-up nut (only for 4 000 N version)
500
2 000
0
C
CPI 10-F
CPI 10-E
0
B
CPI 10-D
1 000
Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs.
0
0
0
100
200
300
400
0
500
100
200
300
400
500
600
700
800
900 1 000
Accessories
Load diagram 2-section
Load diagram 3-section CPI10-D
1 500
4 000
Top mounting plate (without T-slot), Bore 202,2™170,2 mm
Top mounting plate (with T-slot), Bore 202,2™170,2
Bottom mounting plate 3-section, Bore 161,2™129,2 mm
Bottom mounting plate 2-section, Bore 181,8™149,6 mm
Screw for bottom mounting plates M10™25 (1 screw required)
Screw for top mounting plates M8™35 (4 screws required)
Screws for bottom mounting plates M8™35 (4 screws required)
Motor cable 2xDIN8, 1 000 mm, black
Motor cable 2xDIN8, 1 500 mm, black
Motor cable 2xDIN8, 2 500 mm, black
3 000
1 000
2 000
500
1 000
0
0
0
100
200
300
400
500
600
700
800
900 1 000
0
100
200
300
400
500
600
700
800
Designation
Order N°
ZBE–333426
ZBE–333434
ZBE–333428
ZBE–333427
ZBE–510978
ZBE–530564
ZBE–530564
ZKA–306009–1000
ZKA–306009–1500
ZKA–306009–2500
M/0126542
M/0126543
M/0126541
M/0126540
M/0125359
M/0126539
M/0126539
M/0105471
M/0105472
M/0105473
® SKF and Telemag are registered trademarks of the SKF Group
900 1 000
© SKF Group 2011
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Load diagram 3-section CPI10-E
Load diagram 3-section CPI10-F
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10236 EN · Febryary 2011
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
For ophthalmic equipment CPMA
Telescopic pillars
Dimensional drawing
Suitable operating devices
STK01-UW3000-X100
215
CPMA1-1
(4x) †9
16 180
0
CPMA2-2
4
13
18 160 8
0
CPMA1-2
4
Telescopic pillar
140
120
140
120
52
STK01-SW3000-X100
STL01-GW1000-X100
The outlet socket box can be used as a mounting plate.
EHA41-13N00N-000
External power supply 24 V DC
Operating device
(4x) †9
Stroke ±2
Hand switch
Foot switch
Desk switch
For ophthalmic equipment CPMA
Benefits
24 V DC
+
100-240 V AC
L
-
N
PE
Retracted length ±2
Connecting diagrams
PE
Operating
device
… Universal power supply
Operating
device
… Plug and play
(4x) †9
16
18
0
16
… Soft start and stop control
1
13
120
140
8
205,5
4
44
… Multiple outlet socket accessories
… Cable through pillar
M
M
The 2 socket boxes and the mounting plate could be used
Standards
on the inner and outer tube.
… IEC 60601-1:2005
(3rd edition) compliant
Technical data
Unit
CPMA1-1
CPMA1-2
CPMA2-2
Rated push load (with self locking)
Rated pull load
Bending moment (dynamic)
N
N
Nm
1 000
0
up to 115*
2 000
0
up to 250*
2 000
0
up to 250*
Speed (full load to no load)
Telescopic pillar version
Stroke
mm/s
# of section
mm
14 to 15
2-section
230 to 400
11 to 15
2-section
230 to 400
11 to 15
2-section
200 to 400
Retracted length
Static Load (Max) in push way
Static bending moment (Max)
mm
N
Nm
S+160
8 000
500
S+160
8 000
500
S+160
8 000
500
Voltage (rated)
Input current (rated)
Duty cycle: intermittent operation
V
A
on/off
100–240 AC 50/60 Hz
1,5
1 min./9 min.
100–240 AC 50/60 Hz
1,6
1 min./9 min.
24 DC
5
1 min./9 min.
Ambient temperature
Type of protection
Protection class
°C
IP
–
+10 to +40
30
I
+10 to +40
30
I
+10 to +40
30
–
Type of control
Noise level (Max)
Weight
Stand by power (Max)
–
dB(A)
kg
W
electrical
45
8 to 11
1
electrical
45
9 to 12
1
electrical
45
8 to 11
–
* For details, see offset load diagrams
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
0
Telescopic pillars
For ophthalmic equipment CPMA
Offset load diagram
CPMA1-1
Offset load diagram
CPMA1-2 and CPMA2-2
Speed-load diagram
Load [N]
Load [N]
Speed [mm/s]
1 000
2 000
20
900
1 800
18
800
1 600
16
700
12
1 000
10
400
800
8
Underload
n
rrange
400
100
100
200
300
100
200
1 000
0
300
Load distance from the center of the pillar [mm]
Offset load at full extension in the best axis
Only for AC version
1
2
2
Stroke length (mm)
Only for DC version
200
230
250
300
400
Other per 10 mm from 200 mm or 230 mm for AC version up to 400 mm
0
0
Load distance from the center of the pillar [mm]
– 000
1
2
Tube set
2-section
2
0
0
2
4
200
0
Load:
Push (N)
1 000
2 000
CPMA1-2
CPMA2-2
6
600
Underload
d range
g
200
Voltage
100–240 V AC 50/60 Hz
24 V DC
14
Overload range
Ideal range
g
500
300
–
Type
CPMA1-1
1 200
Ideal range
g
Ordering key
C PMA
1 400
Overload range
600
For ophthalmic equipment CPMA
2 000
Load [N]
Offset load at full extension in the best axis
Motor orientation*
Motor in inner tube
Motor in outer tube
More flexibility with Series CPMA design options
Built-in with outer tube on top
Built-in with outer tube on bottom
… More hygienic and easy-to-clean design
… More aesthetic design
M
A
B
Operating device orientation
Operating device socket as the motor
Operating device socket at both sides
LAN cable through
No
LAN cable through
M
A
B
0
1
Not compatible with op. device socket at both sides
*Pillar can be placed with outer tube on the top or bottom (please refer to page 3)
M
M
Motor orientation B Motor orientation A
Accessories
Description
Plug
Country
Part number
Mains cable straight 2,5 m
Schuko
Typ-L
British standard
NEMA
SEV
AS 3112
Germany, France, ...
Italy
UK
USA, Japan, …
CH
PRC, Australia, ...
ZKA-140449-2500
ZKA-140450-2500
ZKA-140451-2500
ZKA-140452-2500
ZKA-140458-2500
ZKA-140460-2500
Detachable mains cord straight 2,5 m
(to plug in socket box Inlet)
Schuko
Typ-L
British standard
NEMA
SEV
AS 3112
Germany, France, ...
Italy
UK
USA, Japan, …
CH
PRC, Australia, ...
ZKA-140453-2500
ZKA-140454-2500
ZKA-140455-2500
ZKA-140456-2500
ZKA-140459-2500
ZKA-140461-2500
M
Fixing armatures available as accessory
11
C-C 2:1
)
ax
M
h)
h
gt
pt
)
de
len
in
M
-in ead
h
ew Thr
pt
cr
(
de
5
7.
-in
ew
cr
(S
6
Stroke ±2
(S
133
(4×
M6
)
×
4×
93
M
6
C
C
RJ45 Operating device location
Retracted length = (Stroke + 160) ±2
Mains power connection
(Terminal block)
RJ 45 LAN location
(S
)
ax
M h)
h
gt
pt
)
de
len
in
M
-in ead
h
ew Thr
pt
cr
(
de
5
7.
-in
ew
cr
(S
6
121
Mains power connection
(Terminal block)
M6
)
M
6
81
(4×
Mounting plate
ZPL-348382
Socket box inlet: IEC, RJ45 LAN, RJ45 op. device
Socket box outlet: 3xIEC, RJ45 LAN, RJ45 op. device
ZDV-348220-002
ZDV-348221-002
© SKF Group 2013
The contents of this publication are the copyright of the publisher and may not be reproduced (even
extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy
of the information contained in this publication but no liability can be accepted for any loss or damage
whether direct, indirect or consequential arising out of the use of the information contained herein.
× D
109,5
124,5
STK01-SW3000-X100
STK01-UW3000-X100
EHA41-13N00N-000
STL01-GW1000-X100
® SKF is a registered trademark of the SKF Group.
4×
RJ45 operating device location
149,5
164,5
11
D-D 2:1
RJ 45 LAN location
Desk switch with LED, cable 0,5 m
Desk switch with LED, cable 1,0 m
Handset with LED, cable coiled 1,3 m
Foot switch, cable coiled 1,3 m
D
Pillar mustt be attached on plane and rigid surface by 4 screws M6 with a depth of 6 to 11 mm in the pillar. The total length of the screw mustt be adjusted to the height of the fixture.
PUB MT/P8 13274 EN · March 2013
3
skf.com
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
For infant care CPMB
Telescopic pillars
Dimensional drawing
drawing
Suitable operating devices
STK01-UW3000-X100
215
CPMB1-1
(4x) †9
16 180
0
CPMB2-2
4
13
18 160 8
0
CPMB1-2
4
Telescopic pillar
140
120
140
120
52
STK01-SW3000-X100
STL01-GW1000-X100
The outlet socket box can be used as a mounting plate.
EHA41-13N00N-000
External power supply 24 V DC
Operating device
(4x) †9
Stroke ±2
Hand switch
Foot switch
Desk switch
For infant care CPMB
Benefits
24 V DC
+
100-240 V AC
L
-
N
PE
Retracted length ±2
Connecting diagrams
PE
Operating
device
… Universal power supply
Operating
device
… Plug and play
(4x) †9
16
18
0
16
… Soft start and stop control
1
13
120
140
8
205,5
4
44
… Low noise level
… Cable through pillar
M
M
… Grounding continuity
The 2 socket boxes and the mounting plate could be used
on the inner and outer tube.
Standards
… IEC 60601-1:2005
(3rd edition) compliant
Technical data
Unit
CPMB1-1
CPMB1-2
CPMB2-2
Rated push load (with self locking)
Rated pull load
Bending moment (dynamic)
N
N
Nm
1 000
0
up to 115*
2 000
0
up to 250*
2 000
0
up to 250*
Speed (full load to no load)
Telescopic pillar version
Stroke
mm/s
# of section
mm
14 to 15
2-section
230 to 400
11 to 15
2-section
230 to 400
11 to 15
2-section
200 to 400
Retracted length
Static Load (Max) in push way
Static bending moment (Max)
mm
N
Nm
S+160
8 000
500
S+160
8 000
500
S+160
8 000
500
Voltage (rated)
Input current (rated)
Duty cycle: intermittent operation
V
A
on/off
100–240 AC 50/60 Hz
1,5
1 min./9 min.
100–240 AC 50/60 Hz
1,6
1 min./9 min.
24 DC
5
1 min./9 min.
Ambient temperature
Type of protection
Protection class
°C
IP
–
+10 to +40
30
I
+10 to +40
30
I
+10 to +40
30
–
Type of control
Noise level (Max)
Weight
Stand by power (Max)
–
dB(A)
kg
W
electrical
45
8 to 11
1
electrical
45
9 to 12
1
electrical
45
8 to 11
–
* For details, see offset load diagrams
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
0
Telescopic pillars
For infant care CPMB
Offset load diagram
CPMB1-1
Offset load diagram
CPMB1-2 and CPMB2-2
Speed-load diagram
Load [N]
Load [N]
Speed [mm/s]
1 000
2 000
20
900
1 800
18
800
1 600
16
700
12
1 000
10
400
800
8
Underload
n
rrange
400
100
100
200
300
100
200
1 000
0
300
Load distance from the center of the pillar [mm]
Offset load at full extension in the best axis
Only for AC version
1
2
2
Stroke length (mm)
Only for DC version
200
230
250
300
400
Other per 10 mm from 200 mm or 230 mm for AC version up to 400 mm
0
0
Load distance from the center of the pillar [mm]
0 – 000
1
2
Tube set
2-section
2
0
0
2
4
200
0
Load:
Push (N)
1 000
2 000
CPMB1-2
CPMB2-2
6
600
Underload
d range
g
200
Voltage
100–240 V AC 50/60 Hz
24 V DC
14
Overload range
Ideal range
g
500
300
–
Type
CPMB1-1
1 200
Ideal range
g
Ordering key
C PMB
1 400
Overload range
600
For infant care CPMB
2 000
Load [N]
Offset load at full extension in the best axis
Motor orientation*
Motor in inner tube
Motor in outer tube
More flexibility with Series CPMB design options
Built-in with outer tube on top
Built-in with outer tube on bottom
… More hygienic and easy-to-clean design
… More aesthetic design
M
A
B
Operating device orientation
Operating device socket as the motor
Operating device socket at both sides
A
B
M
*Pillar can be placed with outer tube on the top or bottom (please refer to page 3)
M
M
Motor orientation B Motor orientation A
Accessories
Description
Plug
Country
Part number
Mains cable straight 2,5 m
Schuko
Typ-L
British standard
NEMA
SEV
AS 3112
Germany, France, ...
Italy
UK
USA, Japan, …
CH
PRC, Australia, ...
ZKA-140449-2500
ZKA-140450-2500
ZKA-140451-2500
ZKA-140452-2500
ZKA-140458-2500
ZKA-140460-2500
Detachable mains cord straight 2,5 m
(to plug in socket box Inlet)
Schuko
Typ-L
British standard
NEMA
SEV
AS 3112
Germany, France, ...
Italy
UK
USA, Japan, …
CH
PRC, Australia, ...
ZKA-140453-2500
ZKA-140454-2500
ZKA-140455-2500
ZKA-140456-2500
ZKA-140459-2500
ZKA-140461-2500
M
Fixing armatures available as accessory
11
C-C 2:1
)
ax
M
h)
h
gt
pt
)
de
len
in
d
M
- in
ea
h
ew Thr
pt
cr
(
de
5
7.
- in
ew
cr
(S
6
Stroke ±2
(S
133
(4×
M6
)
×
4×
93
M
6
C
C
RJ45 Operating device location
D-D 2:1
(S
ew
cr
)
ax
M
h)
h
gt
pt
)
de
len
in
d
M
h
ea
pt
hr
(T
de
-in
ew
cr
(S
Mains power connection
(Terminal block)
M
6
81
M6
)
STK01-SW3000-X100
STK01-UW3000-X100
EHA41-13N00N-000
STL01-GW1000-X100
Mounting plate
ZPL-348382
Socket box inlet: IEC, RJ45 LAN, RJ45 op. device
Socket box outlet: 3xIEC, RJ45 LAN, RJ45 op. device
ZDV-348220-002
ZDV-348221-002
4×
® SKF is a registered trademark of the SKF Group.
© SKF Group 2013
The contents of this publication are the copyright of the publisher and may not be reproduced (even
extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy
of the information contained in this publication but no liability can be accepted for any loss or damage
whether direct, indirect or consequential arising out of the use of the information contained herein.
× D
109,5
124,5
Desk switch with LED, cable 0,5 m
Desk switch with LED, cable 1,0 m
Handset with LED, cable coiled 1,3 m
Foot switch, cable coiled 1,3 m
- in
5
6
7.
121
(4×
RJ45 operating device location
149,5
164,5
11
Retracted length = (Stroke + 160) ±2
Mains power connection
(Terminal block)
D
Pillar mustt be attached on plane and rigid surface by 4 screws M6 with a depth of 6 to 11 mm in the pillar. The total length of the screw mustt be adjusted to the height of the fixture.
PUB MT/P8 13275 EN · March 2013
3
skf.com
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
For medical procedure equipment CPMT
Telescopic pillar
Suitable control units and operating
devices
SCU 5
SCU 9
VCU 5
VCU 8
VCU 9
BCU 5*
BCU 8*
CPMT
l
l
l
l
l
l
l
l
EHA
l
l
l
l
l
l
l
l
STJ
l
l
l
l
l
l
l
l
220
200
1
101 70
190 01
1
15
SCU 1
SKF Telescopic pillar
Dimensional drawing
†10,5
†22 †20
†15
Hand switch
Foot switch
For medical procedure equipment
– series CPMT
4x M10/30
40 Nm
Stroke ±2
EHA is hand switch
STJ is foot switch
STE is desk switch
* Reduced load capacity:
CPMT1-1
up tofor
3 000
N
See
old one
symbols
CPMT1-2 up to 4 000 N
Connecting diagram
24–30 V DC
+
5 V+
GND
… High stroke
… High load capacity
… High safety and reliability
1,5K
… Design flexibility
Standards
1+7
2+4
Limit
Blue
switches
Red
3 5 6 8
Pink
Grey
… IEC 60601-1:2005
Max. Length
2 300 mm
†22
1,5K
Hall A
Hall B
DIN8 connector pins
4× M10/30
40 Nm
146
1
200 70
15
… Low retracted height
129 6
14 3
16
Retracted length ±2
Benefits
†11
†10,5
†11
146 90
1
220
Green
Yellow
2-Hall sensor signal
M
… ANSI/AAMI ES60601-1:2005
Actuator
… IEC 60601-1-2:2007
Technical data
Unit
CPMT1-1S
CPMT1-1M
CPMT1-2S
CPMT1-2M
Rated push load
Rated pull load
Static load (push)1)
Safety factor on rated load2)
Dynamic bending moment
Static bending moment (max.)
N
N
N
5 000
4 000
15 000
4
up to 4503)
1 000
5 000
4 000
15 000
4
up to 1 2003)
3 000
6 000
4 000
15 000
4
up to 5503)
1 000
6 000
4 000
15 000
4
up to 1 4003)
3 000
Retracted length
Stroke (S)
Speed
Voltage
Current (push, max.)
Current (pull, max.)
Duty cycle
Ambient temperature
IP protection
Weight
mm
mm
mm/s
V DC
A
A
on/off
°C
stroke/2 + 120 mm
400 to 600
14 to 34
24 to 30
12
10
1 min./9 min.
+10 to +40
40
16,5 to 20
stroke/2 + 240 mm
300 to 600
14 to 34
24 to 30
12
10
1 min./9 min.
+10 to +40
40
19 to 23,5
stroke/2 + 120 mm
400 to 600
12 to 26
24 to 30
10
7
1 min./9 min.
+10 to +40
40
16,5 to 20
stroke/2 + 240 mm
300 to 600
12 to 26
24 to 30
10
7
1 min./9 min.
+10 to +40
40
19 to 23,5
1)
2)
3)
2
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Nm
Nm
kg
Compliant with static load according to IEC 60601-2-46:2010
Static tensile safety factor to prevent mechanical hazard according to IEC 60601-1:2005
For details, see offset load diagrams
Telescopic pillar
For medical procedure equipment CPMT
Current diagram
Mounting details
Type key
M10
101
Current [A]
14
12
12
101
35
Inner tube
section base
plate
Base plate
M10
Mounting plate
(accessory)
10
MT
50
Outer tube
section base
plate
146
24–30 V DC
CPM
30
1 000
2 000
3 000
4 000
5 000
6 000
Load [N]
Stroke length (mm)
300
350
400
450
500
550
600
Other
per 10 mm from 300 mm (or 400 mm for retracted length S) to 600 mm
2-Hall encoder, end limit switches
SCU/VC
25
24 V
U
15
15
10
10
5
5
0
0
1 000
2 000
3 000
4 000
5 000
6 000
Load [N]
F
Cable options
30 V
20
1 m DIN8 cable
2,3 m DIN8 cable
2,3 m flying leads cable
24 V
1
2
3
Additional attachment options
Configuration options
0
1 000
2 000
3 000
4 000
5 000
Optional threads on outer tube section can
be configured for additional attachment
options. Please contact SKF for more details
6 000
Load [N]
… Choice in size and position
… High strength to support attached
actuators
Offset load diagram
CPMT1-1S, -2S
CPMT1-1M, -2M
Load [N]
7 000
Load [N]
7 000
6 000
6 000
5 000
Only for retracted length M
Only for retracted length M
30
30 V
0
S
M
Electrical options
25
20
0
1
2
Stroke/2 + 120 mm
Stroke/2 + 240 mm
0
CPMT1-2
SCU
/ VCU
0
Retracted length
2
Speed [mm/s]
35
35
0
1
Push (N) Pull (N)
5 000
4 000
6 000
4 000
The pillar must be mounted on a plane and rigid surface by 4 screws
M10 (accessory) with a screw in depth of 25 to 35 mm in the pillar.
Speed [mm/s]
–
0
Load
2
T1-
0
Speed-load diagram
CPMT1-1
–
CP
8
4
15
1
Voltage
1
1-
10
6
146
CPMT
Type
Option S
Option M
DIN8 or flying leads cable for
connectorr flexibility
Accessories
Accessories
Description
Part number
Description
Part number
Control Unit SCU (3 or 6 ports)
Control Unit VCU (3 or 5 ports)
Control Unit BCU (3 ports)
SCUXX-003XXX-000
VCUXX-003XX0-000
BCUX3-XX3100-0000
Top mounting plate
Bottom mounting plate
Screw (4/plate) for mounting plate
SPL-290268
SPL-290265
ZBE-510707
Foot switch STJ (1-3 channels)
Hand switch EHA3 (1-5 channels)
STJ0X-XXXXXX-XX00
EHA3X-23MXXN-000
5 000
overload
overload
4 000
4 000
3 000
2 000
ideal
CPM
T12
3 000
S
2 000
S
CPM
T11
CPMT1-2
M
CPMT1-1
M
ideal
1 000
1 000
underload
underload
0
® SKF is a registered trademark of the SKF Group.
0
0
100
200
300
400
500
600
Load distance from the center of the pillar [mm]
0
100
© SKF Group 2014
The contents of this publication are the copyright of the publisher and may not be reproduced (even
extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy
of the information contained in this publication but no liability can be accepted for any loss or damage
whether direct, indirect or consequential arising out of the use of the information contained herein.
200
300
400
500
600
Load distance from the center of the pillar [mm]
Offset load at full extension
Offset load at full extension
PUB MT/I4 13960 EN · February 2014
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
skf.com
CAWA
Telescopic pillars DC versions
Dimensional drawing
Connecting diagram
15
4
85
78
24 V DC
+
-
11
Telescopic pillar
LS (provided by the customer)
CAWA linear drive profile
M
Actuator
30
Benefits
S+V+113
32
39
134
V
… Lubricated for service life
… High operating reliability
… Selection of front attachments
… Powerful
Min. = V+50 / Max. = S+50
†12
65,5
… Compact
Legend:
S = stroke
L = retracted length
V = carriage (295, 395 or 495 mm)
Technical data
Rated push load
Rated pull load
Speed (full load to no load)
Telescopic pillar version
Stroke
Retracted length
Voltage
Power
Current
Duty cycle: intermittent operation
Ambient temperature
Type of protection
Protection class
Type of control
Weight
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
Unit
CAWA
N
N
mm/s
#of section
mm
mm
V DC
W
A
min.
°C
IP
–
–
kg
1 650
0
14 to 22
N/A
500 to 1 000
S+V+113+75
24
132
5,5
1 min./9 min.
+5 to +40
20
SELV
electrical
10 to 15
75
1
11
116
5
19
21
Telescopic pillars DC versions
CAWA
CAWA
Ordering key
Performance diagrams
Current consumption (A)
Speed (mm/s)
30
7
C AWA
X
2 4 0 0 0
6
5
Type
4
Stroke (S):
50 mm
600 mm
700 mm
800 mm
900 mm
1 000 mm
20
3
10
2
1
0
0500
0600
0700
0800
0900
1000
0
0
500
1 000
1 650
0
500
Speed-load diagram
1 000
Carriage (V):
295 mm
395 mm
495 mm
1 650
Load (N)
Load (N)
295
395
495
Current-load diagram
Motor bracket:
Yes
No
K
0
Cover:
Yes
No
F
0
Voltage (V DC):
24
® SKF is a registered trademark of the SKF Group
© SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB MT/P8 10824 EN · May 2010
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
TMS
Telescopic pillars no motor
0,5 x stroke + 176
Dimensional drawing
Telescopic pillar
1,5 x stroke + 176
TMS
670
0
20
Benefits
… H
Sta
670
… E
20
… U
Legend:
S = stroke
L = retracted length
Technical data
Push load
Pull load
Speed
Stroke
Retracted length
Duty cycle: intermittent operation
Duty cycle: short-time operation
Ambient temperature
Weight
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
Unit
TMS 00
N
N
mm/s
mm
mm
min.
min.
°C
kg
4 000
4 000
N/A
250 to 700
S ™ 0,5 + 176
1 min./9 min.
N/A
+10 to +40
61 to 82
0
Telescopic pillars no motor
TMS
TMS
Ordering key
Performance diagrams
Speed (mm/s)
Motor torque (Nm)
20
0,4
15
0,3
10
0,2
5
0,1
TMS 0 0 – 0 0 0 0 0 0 –
0 0
Type
0
0
0
1 500
3 000
4 500
6 000
0
1 000
2 000
Rotation (rpm)
Speed-rotational diagram
3 000
4 000
Load (N)
Stroke (S):
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
550 mm
600 mm
650 mm
700 mm
250
300
350
400
450
500
550
600
650
700
Torque-load diagram
Options written in italic fonts are only available on demand. Please contact SKF
Bending load diagram
Push load (N)
5 000
4 500
In main load direction X
4 000
3 500
3 000
Ideal range
2 500
2 000
1 500
1 000
Minimum load
500
0
0
500
1 000
1 500
2 000
Loading arm (mm)
® SKF is a registered trademark of the SKF Group
© SKF Group 2009
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
Printed in Sweden on environmentally friendly paper.
PUB L5322,4100 EN · October 2009
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
FRE
Telescopic pillars no motor
Dimensional drawings
B
B
Telescopic pillar
8
22
B
20
22 +10
B
FRE
22 +10
20
30
Benefits
… Attractive design
A
86±0,3
85±0,2
A
A
4xM6
129
146±0,45
… Universal use
A
163±0,4
M5
72±0,3
A
97±0,2
… Stable
M10
M5
146
59,3±0,2
M10
A
146±0,2
76±0,2
4xM5
76±0,2
123,7±0,4
B
102,5
59±0,2
A
A
69
M6
B
113
M6
FRE–A085
FRE–A113
FRE–A146
FRE–D097
FRE–D129
FRE–D163
FRE–B097
FRE–B129
FRE–B163
FRE–E113
FRE–E146
Options written in italic fonts are only available on demand. Please contact SKF
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk
2
163 ™ 163
146 ™ 146
129 ™ 129
113 ™ 113
Retracted length in mm
97 ™ 97
85 ™ 85
76 ™ 76
Profile dimensions in mm
3 sections
Sections
2 sections
Type
B
B
Stroke + 138
Stroke + 148
Stroke + 168
Stroke + 38
Stroke + 53
Stroke + 53
N/A
N/A
N/A
N/A
N/A
Telescopic pillars no motor
FRE
The Power of Knowledge Engineering
Seals
Ordering key
Bearings
and units
Mechatronics
F R E –
–
Lubrication
systems
Services
Drawing on five areas of competence and application-specific expertise amassed over more than 100
years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.
– 0 0 0
Type
Combination:
2 sections tube-set /Largest tube size
85™85 mm
113™113 mm
146™146 mm
97™97 mm
129™129 mm
163™163 mm
3 sections tube-set /Largest tube size
97™97 mm
129™129 mm
163™163 mm
113™113 mm
146™146 mm
4 sections tube-set (on request)
5 sections tube-set (on request)
6 sections tube-set (on request)
7 sections tube-set (on request)
Color:
Natural anodized
Black anodized
Option:
No option
Cover
Pull version
Pull version, with cover
Stroke:
200 mm
300 mm
400 mm
500 mm
600 mm
700 mm
Other stroke lengths
A085
A113
A146
B097
B129
B163
D097
D129
D163
E113
E146
V_
F_
S_
Z_
5
6
000
MCM
MCN
2EA
20
30
40
50
60
70
---
Options written in italic fonts are only available on demand. Please contact SKF
® SKF is a registered trademark of the SKF Group
© SKF Group 2010
The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be
accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB MT/P8 10982 EN · August 2010
Printed in Sweden on environmentally friendly paper.
3
Electro Mechanical Systems Limited
tel: 0118 981 7391
[email protected]
www.ems-limited.co.uk