Telescopic pillars PDF DOCUMENT
Transcription
Telescopic pillars PDF DOCUMENT
Telemag TGC Telescopic pillars AC versions Dimensional drawing PAM-1-130256 †6,5 ,3 †15 59 14 Connecting diagrams Electric L N PE ,3 59 10 59 0 0 ,3 †15 min. 10 76 Retracted length ±2 Telemag TGC †6,5 0 12 Stroke ±2 *Integrated control unit 12 0 0 10 0 ,3 59 min. 10 TGC pneumatic* Hand switch Foot switch Desk switch 12 0 12 Stroke ±2 PFP 1K Telescopic pillar PFP 1 PHC 0 14 76 85 4xM5x15 Retracted length ±2 Suitable control units and accessories 4xM5x15 85 97 2xT6,3 A max Benefits L1 Push or pull load LS L2 N Supporting plate Label position Supporting plate PE 4xM6x22 4xM5x20 Compact design 12 0 14 0 12 Quiet Pneumatic 72 72 0 12 0 86 86 10 0 0 †24,5 †24,5 min. 10 2xT6,3 A max Plug and play PE N min. 10 †6,5 †6,5 L1 2-section Standards 3-section Note: mounting plates are not included. To be ordered separately. Legend: S = stroke L = retracted length LS EN/IEC 60601–1 12 0 14 0 10 L N PE Robust Label position L3 UL 60601–1 Technical data Rated push load Rated pull load Bending load Speed (full load to no load) Telescopic pillar version Stroke Retracted length (push version) Retracted length (pull version) Voltage Power Current Duty cycle: intermittent operation Duty cycle: short-time operation Ambient temperature Type of protection Protection class Type of control Weight * For details, please see bending load diagrams Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 120 V AC 230 V AC 120 V AC 230 V AC 120 V AC 230 V AC 120 V AC 230 V AC 120 V AC 230 V AC Unit TGC 8AWAS TGC 8AWAK TGC 8AWDS TGC 8AWDK N N Nm mm/s mm/s # of section mm mm mm V AC W W A A min. min. min. min. °C IP – – kg 1 000 1 000 up to 130* 11 to 12 9 to 10 2-section 200 to 700 S + 145 S + 150 120 or 230 300 210 2,5 0,95 0,8 min./21 min. 1 min./19 min. 1,5 2 +10 to +40 20/30 I electrical 4,5 to 7,5 1 000 1 000 up to 130* 11 to 12 9 to 10 2-section 200 to 700 S + 145 S + 150 120 or 230 300 210 2,5 0,95 0,8 min./21 min. 1 min./19 min. 1,5 2 +10 to +40 20/30 I pneumatic 4,5 to 7,5 1 000 1 000 up to 450* 11 to 12 9 to 10 3-section 300 to 700 S + 45 S + 50 120 or 230 300 210 2,5 0,95 0,8 min./21 min. 1 min./19 min. 1,5 2 +10 to +40 20/30 I electrical 5,9 to 9,5 1 000 1 000 up to 450* 11 to 12 9 to 10 3-section 300 to 700 S + 45 S + 50 120 or 230 300 210 2,5 0,95 0,8 min./21 min. 1 min./19 min. 1,5 2 +10 to +40 20/30 I pneumatic 5,9 to 9,5 Telescopic pillars AC versions Telemag TGC Telemag TGC Ordering key Performance diagram Speed (mm/s) 40 T G C 8 A W 30 – 0 Type Tube set: Tube set 2™ Tube set 3™ 20 A D Control: Electrical control Pneumatic control Low-voltage control 10 0 0 1 000 2 000 3 000 4 000 Voltage: 230 V AC/50 Hz, IP 30 (no code) 120 V AC/60 Hz, IP 20 Special voltage Load (N) 120 V AC version 230 V AC version Speed-load diagram 2 9 Type of protection /test: Standard IP30 (no code) UL test Bending load diagrams 1 000 Overload range Overload range 800 800 600 600 Ideal range 400 200 Underload range 0 1 3 Stroke (S): 200 mm (only for tube set 2™) 300 mm 400 mm 500 mm 600 mm 700 mm Stroke 700 600 500 400 300 Ideal range 400 U Construction: Push load Customer-specific Pull load Load (N) Load (N) 1 000 200 S K N 2 3 4 5 6 7 Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs. Underload range 0 0 0 50 100 150 200 250 Load distance from center of pillar (mm) Bending load diagram 2-section 0 100 200 300 400 500 600 700 800 Load distance from center of pillar (mm) Accessories Bending load diagram 3-section Top mounting plate for 2 ™ tube set Bottom mounting plate for 2 ™ tube set Top mounting plate for 3 ™ tube set Bottom mounting plate for 3 ™ tube set Screw (4/plate), only for 2 ™ tube set, bottom plate Screw (4/plate), only for 3 ™ tube set, bottom plate Lock washer (4/plate) Plug AC Telemag 3–pin Plug AC Telemag 5–pin Safety factor load conditions Safety factor 20 Designation Order N° SPL–964280 SPL–964281 SPL–964280 SPL–965121 ZBE–510751 ZBE–510709 ZBE–510024 SEL–265518 SEL–265519 M/0125629 M/0125630 M/0125629 M/0125631 M/0125368 M/0125560 M/0125339 M/0124866 M/0124864 18 16 14 12 M9x1,25 10 8 6 *) 4 2 ® SKF is a registered trademark of the SKF Group 0 0 200 400 600 800 © SKF Group 2011 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. 1 000 Stroke (mm) * Safety factor = 4 Printed in Sweden on environmentally friendly paper. PUB L5322,1610 EN · February 2011 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Telemag THC Telescopic pillars AC versions Suitable control units and accessories Dimensional drawing 0 18 0 PAM-1-130256 PFP 1K Telescopic pillar PFP 1 PHC 16 86 86 15 13 0 10 †8,5 †20 †22 †15 min. 10 15 0 18 0 0 S THC pneumatic* Hand switch Foot switch Desk switch Stroke ±2 *Integrated control unit 97 97 Telemag THC 3 11 4xM6x20 Connecting diagrams Electric L 2xT6,3 A max Benefits L1 LS L2 PE N 11 L PE Push or pull load 3 Retracted length ±2 N L3 Label position Supporting plate Quiet 4xM6x25 Pneumatic L N PE Robust 0 16 ,5 2 10 min. 10 2xT6,3 A max Plug and play PE N 15 0 15 13 0 0 2,5 0 18 Powerful 0 18 10 10 †20,5 †8,5 L1 2-section Standards 3-section Note: mounting plates are not included. To be ordered separately. Legend: S = stroke L = retracted length LS EN/IEC 60601–1 9 12 UL 60601–1 Technical data Rated push load Rated pull load Bending load Speed (full load to no load) Telescopic pillar version Stroke Retracted length (push version) Retracted length (pull version) Voltage Power Current Duty cycle: intermittent operation Duty cycle: short-time operation Ambient temperature Type of protection Protection class Type of control Weight * For details, please see bending load diagrams Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 120 V AC 230 V AC 120 V AC 230 V AC 120 V AC 230 V AC 120 V AC 230 V AC 120 V AC 230 V AC Unit THC 8AWAS THC 8AWAK THC 8AWDS THC 8AWDK N N Nm mm/s mm/s # of section mm mm mm V AC W W A A min. min. min. min. °C IP – – kg 1 800 1 800 up to 250* 15 to 20 12 to 17 2-section 200 to 700 S+155 S+160 120 or 230 720 500 6 2,2 0,7 min./30 min. 1 min./27 min. 1 2 +10 to +40 20/30 I electrical 7,9 to 13,5 1 800 1 800 up to 250* 15 to 20 12 to 17 2-section 200 to 700 S+155 S+160 120 or 230 720 500 6 2,2 0,7 min./30 min. 1 min./27 min. 1 2 +10 to +40 20/30 I pneumatic 7,9 to 13,5 1 800 1 800 up to 900* 15 to 20 12 to 17 3-section 230 to 700 S+60 S+65 120 or 230 720 500 6 2,2 0,7 min./30 min. 1 min./27 min. 1 2 +10 to +40 20/30 I electrical 8,6 to 17,5 1 800 1 800 up to 900* 15 to 20 12 to 17 3-section 230 to 700 S+60 S+65 120 or 230 720 500 6 2,2 0,7 min./30 min. 1 min./27 min. 1 2 +10 to +40 20/30 I pneumatic 8,6 to 17,5 Telescopic pillars AC versions Telemag THC Telemag THC Ordering key Performance diagram Speed (mm/s) 40 TH C 8 W – 0 30 Type Load: 1 800 N 1 500 N 1 300 N 20 A B C 10 Tube set: Tube set 2™ Tube set 3™ 0 0 1 000 2 000 3 000 Load (N) Control: Electrical control Pneumatic control Low-voltage control 120 V AC version 230 V AC version Speed-load diagram A D 4 000 S K N Voltage: 230 V AC/50 Hz, IP 30 (no code) 120 V AC/60 Hz, IP 20 Special voltage Bending load diagrams Load (N) 2 9 Type of protection /test: Standard IP30 (no code) UL test Load (N) U 2 000 2 000 Construction: Push load Customer-specific Pull load Overload range Overload range 1 500 1 500 Stroke 0 1 3 700 Stroke (S): 200 mm (only for tube set 2™) 300 mm 400 mm 500 mm 600 mm 700 mm 1 000 1 000 Ideal range Ideal range 600 500 400 500 500 300 Underload range Underload range 0 0 0 50 100 150 200 250 300 Load distance from center of pillar (mm) 0 200 400 600 800 1 000 Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs. Load distance from center of pillar (mm) Bending load diagram 3-section Bending load diagram 2-section Safety factor load conditions Accessories Top mounting plate for 2 ™ tube set Bottom mounting plate for 2 ™ tube set Top mounting plate for 3 ™ tube set Bottom mounting plate for 3 ™ tube set Screw (4/plate) for top mounting plate Screw (4/plate) for bottom mounting plate Plug AC Telemag 3 pin Plug AC Telemag 5 pin Safety factor 20 18 16 14 12 2 3 4 5 6 7 Tr 12,5 x 1,6 10 Designation Order N° SPL–264265 SMT–264363 SPL–264265 SPL–264237 ZBE–510671 ZBE–510709 SEL–265518 SEL–265519 M/0125688 M/0124814 M/0125688 M/0125622 M/0125628 M/0125560 M/0124866 M/0124864 8 6 *) 4 2 ® SKF is a registered trademark of the SKF Group 0 0 200 400 600 800 © SKF Group 2010 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. 1 000 Stroke (mm) * Safety factor = 4 Printed in Sweden on environmentally friendly paper. PUB L5322,1620 EN · May 2010 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Telemag THG Telescopic pillars DC versions Suitable control units and accessories Dimensional drawing Telescopic pillar MCU BCU 8 BCU 5 VCU 9 VCU 8 VCU 5 SCU 9 SCU 5 SCU 1 Control units 8,5 180 160 THG EHA 1 15 0 18 0 13 15 0 0 86 86 10 10 EHA 3 22 STF 20 STJ Stroke ±2 STA STE Hand switch Foot switch Desk switch 20 S Telemag THG 20 97 97 3 11 Retracted length ±2 Connecting diagram* Compact design Robust 113 24 V DC + 5V+ Standards 4xM6/25 9Nm GND 1,5K EN/IEC 60601–1 DIN8 plug UL 60601–1 9 12 L Benefits 4xM6/25 9Nm 1+7 1,5K 15 0 Hall A Hall B 180 0 16 2,5 10 3 5 6 8 2+4 13 15 0 0 0 18 10 2,5 10 Blue Red 10 20,5 M 8,5 2 Hallsensors signal 2-section 3-section Actuator * Only valid with THG11. THG10 must be operated by a BCU, SCU or VCU control unit. Legend: S = stroke L = retracted length Note: mounting plates are not included. To be ordered separately. Technical data Rated push load Rated pull load Bending load Speed (full load to no load) Telescopic pillar version Stroke Retracted length Voltage Power Current Duty cycle: intermittent operation Ambient temperature Type of protection Protection class Type of control Weight * for details, please see bending load diagrams Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 Unit THG 10/11–BA THG 10/11–CA THG 10/11–BD THG 10/11–CD N N Nm mm/s # of section mm mm V DC W A min. °C IP – – kg 2 000 0 up to 250* 5 to 7 2-section 200 to 700 S+270 24 120 5 1 min./9 min. +10 to +40 30 SELV electrical 8 to 14 1 000 0 up to 120* 12 to 15 2-section 200 to 700 S+270 24 120 5 1 min./9 min +10 to +40 30 SELV electrical 8 to 14 2 000 0 up to 1 000* 5 to 7 3-section 200 to 700 S+180 24 120 5 1 min./9 min +10 to +40 30 SELV electrical 8 to 14 1 000 0 up to 450* 12 to 15 3-section 200 to 700 S+180 24 120 5 1 min./9 min +10 to +40 30 SELV electrical 8 to 14 Telescopic pillars DC versions Telemag THG Telemag THG Ordering key Performance diagrams Speed (mm/s) Current consumtion (A) 16 12 THG 1 – – 0 0 0 C 12 9 8 6 Type B 4 3 0 0 0 500 1 000 1 500 2 000 Voltage: 24 V DC 24 V DC with integrated current cut-off B C Load: 2 000 N 1 000 N 0 500 1 000 1 500 Load (N) Stroke (S): 200 mm 300 mm 400 mm 500 mm 600 mm 700 mm Load (N) Load (N) Overload range Overload range Overload range 800 1 500 1 500 Stroke 700 1 000 Ideal range 600 Ideal range 500 Stroke 700 600 600 400 500 300 Underload range 300 200 400 600 800 1 000 Bending load diagram THG...BD Ideal range 200 THG...CA Underload range Underload range 0 0 Load distance from center of pillar (mm) 500 0 100 200 300 400 500 600 700 800 Load distance from center of pillar (mm) Bending load diagram THG...CD 0 50 100 150 200 250 1 2 A 3 4 B Option: No option 1-Hall encoder, 8 pulses, cable with jack plug Potentiometer, 1 kΩ, 2 Watt, 0,25 % linearity, 10 turns (tube set 3™ only) Cable feedthrough, 5 ™ 0,75 mm2, top +160 mm, bottom +800 mm Cable feedthrough, 1-Hall encoder Cable feedthrough, potentiometer (tube set 3™ only) 2-Hall encoder, cable with DIN8 plug Cable feedthrough, 2-Hall encoder, cable with DIN8 plug THG...BA 400 200 0 Ideal range 1 000 500 400 2 3 4 5 6 7 Cable / connecting plug: Straight, 1,0 m / jack plug Straight, 2,3 m / jack plug Coiled, 0,6 m / jack plug Straight, 1,0 m / DIN8 plug Straight, 2,3 m / DIN8 plug Coiled, 0,6 m / DIN8 plug Load (N) 2 000 1 000 2 000 200 A D Current-load diagram Bending load diagrams 0 B C Tube set: Tube set 2™ Tube set 3™ 2 000 Load (N) Speed-load diagram 0 1 300 Load distance from center of pillar (mm) 0 A B C D E F G Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs. Bending load diagram THG...BA/CA Safety factor load conditions Accessories Safety factor Top mounting plate for 2 ™ tube set Bottom mounting plate for 2 ™ tube set Top mounting plate for 3 ™ tube set Bottom mounting plate for 3 ¥ tube set Screw (4/plate) for mounting plate (2 tube set) Screw (4/plate) for mounting plate (3 tube set) 24 18 B/Tr 15x5 Designation Order N° SPL–264265 SMT–264363 SPL–264265 SPL–264237 ZBE–510709 ZBE–510707 M/0125688 M/0124814 M/0125688 M/0125622 M/0125560 M/0125360 12 6 *) C/Tr 12,5x10 ® SKF is a registered trademark of the SKF Group 0 0 250 500 750 © SKF Group 2010 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. 1 000 Stroke (mm) * Safety factor = 4 Printed in Sweden on environmentally friendly paper. PUB L5322,1650 EN · May 2010 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Telemag TLC Telescopic pillars AC versions Suitable control units and accessories Dimensional drawing PAM-1-130256 PFP 1K Telescopic pillar PFP 1 PHC 22 0 0 19 10 1 1 10 20 0 17 0 0 22 15 †11 15 †20 †22 S TLC pneumatic* Hand switch Foot switch Desk switch Stroke ±2 *Integrated control unit 9 12 9 12 Telemag TLC 4xM10x30 Retracted length ±2 Electric L N PE 2xT6,3 A max 6 14 6 14 L Connecting diagrams Benefits 20 0 3 16 Label position L1 Push or pull load L2 PE N L3 Supporting plate 4xM10x30 LS High bending load 22 20 0 0 Quiet Pneumatic 9 12 L 15 0 †11 †22 2xT6,3 A max Plug and play PE N L1 2-section Standards 3-section Note: mounting plates are not included. To be ordered separately. Legend: S = stroke L = retracted length LS EN/IEC 60601–1 20 15 N PE Powerful 0 22 17 0 12 9 0 19 UL 60601–1 Technical data Rated push load Rated pull load Bending load Speed (full load to no load) Telescopic pillar version Stroke Retracted length (push version) Retracted length (pull version) Voltage Power Current Duty cycle: intermittent operation Duty cycle: short-time operation Ambient temperature Type of protection Protection class Type of control Weight * For details, please see bending load diagrams Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 120 V AC 230 V AC 120 V AC 230 V AC 120 V AC 230 V AC 120 V AC 230 V AC 120 V AC 230 V AC Unit TLC 12ZWAS TLC 12ZWAK TLC 12ZWDS TLC 12ZWDK N N Nm mm/s mm/s # of section mm mm mm V AC W W A A min. min. min. min. °C IP – – kg 4 000 4 000 up to 630* 15 to 22 11 to 17 2-section 100 to 700 S+175 S+185 120 or 230 1 200 890 10 4,1 0,8 min./37 min. 1 min./37 min. 1,2 2 +10 to +40 20/30 I electrical 15,2-24,5 4 000 4 000 up to 630* 15 to 22 11 to 17 2-section 100 to 700 S+175 S+185 120 or 230 1 200 890 10 4,1 0,8 min./37 min. 1 min./37 min. 1,2 2 +10 to +40 20/30 I pneumatic 15,2-24,5 4 000 4 000 up to 2 100* 15 to 22 11 to 17 3-section 255 to 700 S+60 S+70 120 or 230 1 200 890 10 4,1 0,8 min./37 min. 1 min./37 min. 1,2 2 +10 to +40 20/30 I electrical 18,3-30,5 4 000 4 000 up to 2 100* 15 to 22 11 to 17 3-section 255 to 700 S+60 S+70 120 or 230 1 200 890 10 4,1 0,8 min./37 min. 1 min./37 min. 1,2 2 +10 to +40 20/30 I pneumatic 18,3-30,5 Telescopic pillars AC versions Telemag TLC Telemag TLC Ordering key Performance diagram Speed (mm/s) 40 T L C 12 30 W – 0 Type Load: 4 000 N 3 000 N 2 000 N 20 Z X S 10 Tube set: Tube set 2™ Tube set 3™ 0 0 1 000 2 000 3 000 Control: Electrical control Pneumatic control Low-voltage control Load (N) 120 V AC version 230 V AC version Speed-load diagram A D 4 000 S K N Voltage: 230 V AC/50 Hz (no code) 120 V AC/60 Hz Special voltage Bending load diagrams Load (N) Type of protection/test: Standard IP30 (no code) UL approved Load (N) 4 000 2 9 U 4 000 Overload range Construction: Push load Customer-specific Pull load Overload range 3 000 3 000 0 1 3 Stroke 2 000 Stroke (S): 100 mm, only for tube set 2™, push 255 mm, only for tube set 3™, push 200 mm, only for tube set 2™ 300 mm 400 mm 500 mm 600 mm 700 mm 700 2 000 Ideal range Ideal range 600 500 1 000 1 000 400 300 Underload range 0 0 100 200 300 Underload range 0 400 Load distance from center of pillar (mm) 0 200 400 600 800 1 000 Load distance from center of pillar (mm) Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs. Bending load diagram 3-section Bending load diagram 2-section Safety factor load conditions Accessories Top mounting plate for 2 ™ tube set Bottom mounting plate for 2 ™ tube set Top mounting plate for 3 ™ tube set Bottom mounting plate for 3 ™ tube set Screw (4/plate) for mounting plate Plug AC Telemag 3 pin Plug AC Telemag 5 pin Safety factor (screw buckling) 20 18 16 Tr 16x2,5 14 1 1 2 3 4 5 6 7 12 Designation Order N° SPL–290268 SPL–290351 SPL–290268 SPL–290265 ZBE–510707 SEL–265518 SEL–265519 M/0125624 M/0125625 M/0125624 M/0125623 M/0125360 M/0124866 M/0124864 10 8 6 *) 4 2 ® SKF is a registered trademark of the SKF Group 0 0 200 400 600 800 © SKF Group 2011 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. 1 000 Stroke (mm) * Safety factor = 4 Printed in Sweden on environmentally friendly paper. PUB L5322,1630 EN · February 2011 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Telemag TLG Telescopic pillars DC versions Suitable control units and accessories Dimensional drawing Telescopic pillar MCU BCU 8 BCU 5 VCU 9 VCU 8 VCU 5 SCU 9 SCU 5 SCU 1 Control units †11 0 19 EHA1 EHA3 17 10 1 †20 1 10 †11 0 0 19 10 1 †20 01 1 15 17 0 0 †22 †22 STJ 20 0 22 0 15 STF Telemag TLG 20 0 22 TLG 25 25 Hand switch Foot switch Desk switch Stroke ±2 Stroke ±2 STA STE 25 25 9 12 9 12 4 x M10/30 40 Nm Connecting diagram* High bending load Powerful 6 14 Retracted length ±2 Retracted length ±2 4 x M10/30 40 Nm Benefits 6 14 3 16 24 V DC + 5V+ GND 1,5K EN/IEC 60601–1 DIN8 plug UL 60601–1 1+7 2+4 Blue Red M 4 x M10/30 40 Nm 4 x M10/30 40 Nm 1,5K Hall A Hall B 22 20 0 17 0 0 19 12 9 12 3 5 6 8 15 †22 0 20 0 22 9 17 †11 0 0 0 19 14 6 14 15 Standards 6 †22 †11 2 Hallsensors signal 2-section 3-section Actuator * Only valid with TLG11. TLG10 must be operated by a BCU, MCU, SCU or VCU control unit. Note: mounting plates are not included. To be ordered separately. Legend: S = stroke L = retracted length Technical data Rated push load Rated pull load Bending load Speed (full load to no load) Telescopic pillar version Stroke Retracted length Voltage Power Current Duty cycle: intermittent operation Ambient temperature Type of protection Protection class Type of control Weight * For details, please see bending load diagrams 2 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Unit TLG 10/11–A TLG 10/11–B TLG 10/11–C N N Nm mm/s # of section mm mm V DC W A min. °C IP – – kg 4 000 0 up to 2 800* 10 to 14 2 or 3-section 200 to 700 S+180 24 156 6,5 1 min./9 min +10 to +40 30 SELV electrical 15 to 30 2 500 0 up to 1 750* 13 to 17 2 or 3-section 200 to 700 S+180 24 156 6,5 1 min./9 min +10 to +40 30 SELV electrical 15 to 30 1 500 0 up to 950* 25 to 33 2 or 3-section 200 to 700 S+180 24 156 6,5 1 min./9 min +10 to +40 30 SELV electrical 15 to 30 Telescopic pillars DC versions Telemag TLG Telemag TLG Ordering key Performance diagrams T L G 1 Speed (mm/s) – – 0 0 0 Current consumtion (A) 40 12 Type C 30 Voltage: 24 V DC 24 V DC with integrated current cut-off 9 B C 20 A 0 1 6 Load: 4 000 N 2 500 N 1 500 N B 10 3 A 0 Tube set: Tube set 2™ Tube set 3™ 0 0 1 000 2 000 3 000 4 000 0 1 000 2 000 3 000 Load (N) 4 000 Load (N) Bending load diagrams Load (N) 2 500 Overload range Overload range 2 000 3 000 Stroke 700 Ideal range 600 700 Ideal range 1 000 600 500 1 000 400 500 400 500 300 Underload range 300 200 0 200 Underload range 0 0 200 400 600 800 1 000 1 200 1 400 0 Load distance from center of pillar (mm) 200 400 600 800 0 A B C D E F G 1 000 1 200 1 400 Load distance from center of pillar (mm) Bending load diagram TLG ...AD 1 2 A 3 4 B Option: No option 1-Hall encoder, 8 pulses, cable with jack plug Potentiometer, 1 kΩ, 2 Watt, 0,25 % linearity, 10 turns Cable feedthrough, 5 ™ 0,75 mm2, led out, top +160 mm, bottom +800 mm Cable feedthrough, 1-Hall encoder Cable feedthrough, potentiometer 2-Hall encoder, cable with DIN8 plug Cable feedthrough, 2-Hall encoder, cable with DIN8 plug 1 500 Stroke 2 000 2 3 4 5 6 7 Cable / connecting plug: Straight, 1,0 m / jack plug Straight, 2,3 m / jack plug Coiled, 0,6 m / jack plug Straight, 1,0 m / DIN8 plug Straight, 2,3 m / DIN8 plug Coiled, 0,6 m / DIN8 plug Load (N) 4 000 A D Stroke (S): 200 mm 300 mm 400 mm 500 mm 600 mm 700 mm Current-load diagram Speed-load diagram A B C Options written in italic fonts are only available on demand. Please contact SKF Bending load diagram TLG ...BD Safety factor load conditions Accessories Safety factor 20 C / Tr 12,5 x 10 15 Load (N) Load (N) 1 500 B / Tr 15 x 5 4 000 Overload range Overload range 3 500 Stroke 700 5 2 500 2 000 500 500 1 500 400 1 000 200 0 200 400 600 800 1 000 1 200 Load distance from center of pillar (mm) Bending load diagram TLG ...CD SPL–290268 SPL–290351 SPL–290268 SPL–290265 ZBE–510707 M/0125624 M/0125625 M/0125624 M/0125623 M/0125360 0 0 500 250 500 750 1 000 Stroke (mm) TLG1-AA TLG1-BA TLG1-CA * Safety factor = 4 Underload range ® SKF is a registered trademark of the SKF Group 0 0 Top mounting plate for 2 ™ tube set Bottom mounting plate for 2 ™ tube set Top mounting plate for 3 ™ tube set Bottom mounting plate for 3 ™ tube set Screw (4/plate) for mounting plate A / Kr 14 x 4 Ideal range 300 Underload range Order N° *) Ideal range 600 Ideal range Designation Ideal range 3 000 1 000 10 Description 0 50 100 150 200 250 300 350 400 © SKF Group 2010 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. Load distance from center of pillar (mm) Bending load diagram TLG...AA/BA/CA Printed in Sweden on environmentally friendly paper. PUB L5322,1660 EN · May 2010 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Telemag TLT Telescopic pillars DC versions Suitable control units and accessories Dimensional drawing Control units †22 BCU 8 10 0 19 01 1 EHA3 STJ 25 29 N1 4™M10 30 mm deep Retracted length ±4 Connecting diagram* (without mounting plates) Supporting plate Very small built-in dimension Powerful †11 25 STE Hand switch Foot switch Desk switch Benefits 20 0 0 17 1 15 TLT Telemag TLT †20 0 Stroke ±4 BCU 5 VCU 9 VCU 8 VCU 5 SCU 9 SCU 1 Telescopic pillar SCU 5 22 46 N1 63 N1 24 VDC + 5V+ Standards 4™M10 30 mm deep GND 1,5K EN/IEC 60601–1 1+7 2+4 Blue Red 1,5K Hall A Hall B DIN8 plug UL 60601–1 1,5K 3 5 6 8 2+4 Blue Red Supporting plate Hall A Hall B DIN8 plug 1+7 1,5K 22 0 0 19 3 5 6 8 17 0 14 20 0 6 6 14 †22 15 M 2 Hallsensors signal M Actuator 2 Hallsensors signal †11 Max. length 2 300 mm Actuator Legend: S = stroke L = retracted length * Only valid with TLT11. TLT10 must be operated by a BCU, SCU or VCU control unit. Note: mounting plates are not included. To be ordered separately. Technical data Rated push load Rated pull load Bending load Speed (full load to no load) Telescopic pillar version Stroke Retracted length Voltage Power Current Duty cycle: intermittent operation Ambient temperature Type of protection Protection class Type of control Weight * For details, please see bending load diagrams Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 Unit TLT10–A1 TLT10–A2 TLT10–B1 TLT10–C1 TLT10–C2 N N Nm mm/s # of section mm mm V DC W A min. °C IP – – kg 3 000 0 up to 400* 11 to 16 3-section 300 to 700 0,5 ™ S+170 24 168 2™3,5 1 min./9 min +10 to +40 40 SELV electrical 15 to 30 4 000 0 up to 1 000* 13 to 19 3-section 300 to 700 0,5 ™ S+240 24 168 2™3,5 1 min./9 min +10 to +40 40 SELV electrical 15 to 30 2 000 0 up to 250* 13 to 19 3-section 300 to 700 0,5 ™ S+170 24 192 2™4,0 1 min./9 min +10 to +40 40 SELV electrical 15 to 30 1 000 0 up to 110* 25 to 36 3-section 300 to 700 0,5 ™ S+170 24 192 2™4,0 1 min./9 min +10 to +40 40 SELV electrical 15 to 30 2 000 0 up to 480* 25 to 42 3-section 300 to 700 0,5 ™ S+240 24 216 2™4,5 1 min./9 min +10 to +40 40 SELV electrical 15 to 30 Telescopic pillars DC versions Telemag TLT Telemag TLT Ordering key Performance diagrams Speed (mm/s) Current consumption (A) 5,0 40 T L T 1 – – 0 0 0 4,5 36 32 4,0 C1 B1 28 3,5 24 3,0 C1 Type A1 Voltage: 24 V DC 24 V DC with integrated current cut-off (only for A2 and C2) 2,5 20 B1 16 2,0 A1 12 1,5 8 1,0 4 0,5 Load / Speed: 4 000 N 3 000 N 2 000 N / 19 to 13 mm/s 2 000 N / 42 to 25 mm/s 1 000 N 0 0 1 000 2 000 3 000 0 4 000 1 000 2 000 3 000 4 000 Load (N) Load (N) Speed-load diagram 5,0 45 4,5 40 4,0 35 C2 3,5 C2 3,0 25 2,5 20 2,0 A2 15 1,5 10 1,0 5 0 A C D F Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs. 0,5 0 1 2 A 3 4 B Option: No option 1-Hall encoder, 8 pulses, cable with jack plug Cable feedthrough, 3x1,5 mm2, top +160 mm, bottom +800 mm Cable feedthrough, 1-Hall encoder 2-Hall encoder, cable with DIN8 plug A2 30 3 4 5 6 7 Cable / connecting plug: Straight, 1,0 m / jack plug Straight, 2,3 m / jack plug Coiled, 0,6 m / jack plug Straight, 1,0 m / DIN8 plug Straight, 2,3 m / DIN8 plug Coiled, 0,6 m / DIN8 plug Current consumption (A) 50 A2 A1 B1 C2 C1 Stroke (S): 300 mm 400 mm 500 mm 600 mm* 700 mm* Current-load diagram Speed (mm/s) 0 1 0 0 1 000 2 000 3 000 4 000 0 1 000 2 000 3 000 4 000 Load (N) Load (N) Speed-load diagram Current-load diagram * Reduced safety factor Bending load diagrams Accessories Load (N) Top mounting plate Bottom mounting plate Screw (4/plate) for mounting plate 4 000 Overload range Overload range 3 500 2 600 Ideal range 2 200 M/0125624 M/0125623 M/0125360 Ideal range 2 500 1 800 1 600 2 000 Ideal range 1 200 SPL–290268 SPL–290265 ZBE–510707 3 000 2 000 1 400 Order N° Load (N) 3 000 2 800 2 400 Designation TLT1 A-1 TLT1 A-2 1 500 1 000 800 600 TLT1 B-1 Ideal range 400 TLT1 C-2 500 200 Underload range 0 0 Ideal range 1 000 50 100 150 200 250 TLT1 C-1 300 Load distance from center of pillar (mm) Bending load diagram A1, B1, C1 Underload range 0 0 100 200 300 400 ® SKF is a registered trademark of the SKF Group © SKF Group 2011 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. 500 Load distance from center of pillar (mm) Bending load diagram A2, C2 Printed in Sweden on environmentally friendly paper. PUB L5322,1670 EN · February 2011 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Telemag TFG Telescopic pillars Suitable control units and accessories Dimensional drawing Control units 72 17 TFG 90 Integrated control unit 0 11 N EHA3 STJ STE 1xM 35 N 10/16 m LD-034.000.004 Retracted length = stroke +130 mm LD-011.031.000 Hand switch Foot switch Desk switch Benefits Connecting diagrams Compact design Fast movement 25 4xM6/ 9 Nm 3 13 N PE 1,5K DIN8 plug Standards EN/IEC 60601–1 Limit switches UL 60601–1 1+7 2+4 Blue Red 1,5K Operating device Hall A Hall B 3 5 6 8 2 Hallsensors signal M Actuator Note: mounting plates are not included. To be ordered separately. % & Option & M Legend: S = stroke L = retracted length Technical data Rated push load Rated pull load Bending load Speed (full load to no load) Telescopic pillar version Stroke Retracted length Voltage Power Current Duty cycle: intermittent operation Duty cycle: short-time operation Ambient temperature Type of protection Protection class Type of control Weight * For details, please see bending load diagrams tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 0 13 5 /2 M6 4x Nm 9 N GND Plug and play N10 2,5 196 120/230 V AC L 24 V DC + 5V+ Powerful Electro Mechanical Systems Limited 1 12 10 Push or pull load N 250 Telemag TFG 7 20 2 Stroke Telescopic pillar Integrated control unit 180 160 72 4x†8, 5 TFG 10 TFG 50 20 Min. 10 STE STJ EHA3 LD 015 LD 014 BCU 8 BCU 5 VCU 9 VCU 8 VCU 5 SCU 9 SCU 5 SCU 1 0 15 130 2 7 17 Unit TFG 10 TFG 50 TFG 90 N N Nm mm/s # of section mm mm V AC W A min. min. °C IP – – kg 2 500 2 500 up to 500* 15 to 19 3-section 200 to 700 S+130 24 120 5 1 min./9 min. 3 +10 to +40 30 SELV electrical 8 to 19 2 500 2 500 up to 500* 15 to 19 3-section 200 to 700 S+130 120 160 1,8 1 min./9 min. 3 +10 to +40 30 1 electrical 8 to 19 2 500 2 500 up to 500* 15 to 19 3-section 200 to 700 S+130 230 160 1 1 min./9 min. 3 +10 to +40 30 1 electrical 8 to 19 Telescopic pillars Telemag TFG Telemag TFG Ordering key Performance diagrams Speed (mm/s) Current consumption (A) 20 T F G 0 – 2 3 – 0 0 0 6 19 5 Type 18 4 17 16 Voltage: 24 V DC 120 V AC (50/60 Hz) 230 V AC (50 Hz) 3 15 2 1 5 9 14 Stroke (S): 200 mm 250 mm 300 mm 350 mm 400 mm 500 mm 700 mm 1 13 12 0 500 0 1 000 1 500 2 000 2 500 0 500 1 000 1 500 2 000 Load (N) 2 500 Load (N) Speed-load diagram Current-load diagram TFG 10 TFG 50 TFG 90 200 250 300 350 400 500 700 Option: No option With 2-Hall encoder, 14 pulses per 9 mm travel With mains cable feedthrough (3xAWG16) With control cable feedthrough (10xAWG28) 000 E C H Bending load diagrams Load (N) Load (N) Load (N) 2 500 2 500 2 500 2 000 2 000 2 000 Accessories 1 500 1 500 1 500 Top mounting plate Bore 72 ™ 72 mm Bottom mounting plate Bore 102,5 ™ 102,5 mm Screw for top mounting plate M10 ™ 25 (1 screw required) Screw for top mounting plate M6 ™ 30 (4 screws required) Screw for bottom mounting plate M6 ™ 30 (4 screws required) Mains cable SEV plug 3 000 mm, black, 3 ™ 0.75 mm2 Mains cable Schuko plug 3 000 mm, black, 3 ™ 0.75 mm2 Mains cable US plug 3 000 mm, black, 3 ™ 0.75 mm2 Mains cable British Standard plug 3 000 mm, black, 3 ™ 0.75 mm2 Ideal load Ideal load 1 000 1 000 1 000 Slipstickarea Slipstickarea Ideal load 500 500 500 Ideal load 0 0 0 200 400 600 800 0 0 1 000 Load distance from center of pillar (mm) 200 400 600 800 1 000 Overload Ideal load 1 000 500 Ideal load 0 600 800 1 000 Load distance from center of pillar (mm) 500 mm stroke 1 000 Ideal load 1 000 500 Ideal load Ideal load ® SKF is a registered trademark of the SKF Group 0 0 400 800 Overload Ideal load 500 600 1 500 1 500 200 400 2 000 2 000 1 000 M/0124808 M/0124814 M/0125359 M/0125560 M/0125560 M/0125331 M/0121729 M/0121762 M/0121755 Load (N) Overload 1 500 SMT–333360 SMT–264363 ZBE–510978 ZBE–510709 ZBE–510709 ZKA–304345 ZKA–304346–3000 ZKA–304347–3000 ZKA–304355–3000 2 500 2 500 2 000 Order N° 400 mm stroke Load (N) Load (N) 200 Load distance from center of pillar (mm) 300 mm stroke 2 500 0 0 Load distance from center of pillar (mm) 200 mm stroke Designation Overload Overload Overload 0 200 400 600 800 1 000 Load distance from center of pillar (mm) 600 mm stroke 0 200 400 600 800 © SKF Group 2010 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. 1 000 Load distance from center of pillar (mm) 700 mm stroke Printed in Sweden on environmentally friendly paper. PUB L5322,1675 EN · August 2010 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Telesmart TXG Telescopic pillars Suitable control units and accessories Dimensional drawing Control units STA* STF* EHE1 LD 015 LD 014 BCU 8 BCU 5 VCU 9 VCU 8 VCU 5 0 15 0 12 55 14 0 12 0 10 †9 TXG 1 TXG 4 Integrated control unit 14 0 Stroke ±2 TXG 5 Integrated control unit Telescopic pillar 19 0 TXG 8 Integrated control unit TXG 9 Integrated control unit 18 0 Supporting plate EHA3 R 300 STJ Telesmart TXG 4¥M6¥40 DIN 7 500 included Benefits * only with FCC plug Retracted length ±2 LD-011.031.000 Hand switch Foot switch Desk switch (without mounting plates) STE LD-034.000.004 12 0 Connecting diagrams Powerful and fast lifting Supporting plate 0 15 0 12 Aesthetic design 120/230 V AC L 24 V DC + Standards 4¥M6¥40 DIN 7 500 included 19 0 10 N EN/IEC 60601–1 22 0 17 0 85 †9 PE UL 60601–1 Black Red Note: mounting plates are not included. To be ordered separately. Limit switches M Actuator M Legend: S = stroke L = retracted length Technical data Rated push load Rated pull load Bending load Speed (full load to no load) Telescopic pillar version Stroke Retracted length Voltage Power Current Duty cycle: intermittent operation Duty cycle: short-time operation Ambient temperature Type of protection Protection class Type of control Weight 1) For details, see bending load diagrams for cable feedthrough option 2) Mandatory Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 Unit TXG1 TXG4/5 TXG8/9 N N Nm mm/s # of section mm mm V AC W A min. min. °C IP – – kg 1 500 0 up to 2101) 17 to 23 2-section 200 to 600 S+180 24 – 5 1 min./9 min. – +10 to +40 30 SELV electrical 8 to 13 1 500 0 up to 2101) 17 to 23 2-section 200 to 600 S+180 120 N/A 1,8 1 min./9 min. N/A +10 to +40 30 II/(I)2) electrical 9 to 14 1 500 0 up to 2101) 17 to 23 2-section 200 to 600 S+180 230 N/A 0,9 1 min./9 min. N/A +10 to +40 30 II/(I)2) electrical 9 to 14 Telescopic pillars Telesmart TXG Telesmart TXG Ordering key Performance diagram Speed (mm/s) 25 T X G 0 – 0 0 – 0 0 20 Type 15 Voltage: 24 V DC (slave actuator) 120 V AC, 50/60 Hz, class II 120 V AC, 50/60 Hz, class I (mandatory for cable feedthrough option) 230 V AC, 50 Hz, class II 230 V AC, 50 Hz, class I (mandatory for cable feedthrough option) 10 5 0 0 500 1 000 1 4 5 8 9 Color: Natural anodized coating Customer-specific Powder-coated white Powder-coated grey 1 500 Load (N) Speed-load diagram 5 K 2 3 Option: None Control connection feedthrough Mains cable feedthrough Control connection feedthrough, mains cable feedthrough Customer-specific Bending load diagram 000 EYX EYF 2AA KKK Stroke (S) / Retr. length (L=S+180 or L= S+160 mm) 200 mm 300 mm 400 mm 500 mm 600 mm Load (N) 1 600 1 400 L=S+180 200 300 400 500 600 L=S+160 4CY 4DY 4EY 4FY 4GY Overload range 1 200 Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs. 1 000 800 Ideal range 600 400 Underload range 200 Accessories 0 0 75 150 225 300 Load distance from center of pillar (mm) Safety factor load conditions Mains cable Plug Country Order number Comment Straight cable 3,5 Straight cable 3,5 Straight cable 3,5 Straight cable 3,5 Euro Schuko UL British standard General General USA UK M/0121730 M/0121760 M/0121757 M/0121761 2-pole 3-pole 2-pole/3-pole 2-pole/3-pole Top or bottom mounting plate M/0124874 Note: mounting screws are included in the TXG. Safety factor (screw buckling) 20 15 10 5 ® SKF is a registered trademark of the SKF Group © SKF Group 2010 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. 0 0 150 300 450 600 Stroke (mm) Printed in Sweden on environmentally friendly paper. PUB L5322,1680 EN · August 2010 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Telesmart TMA Telescopic pillars DC versions Suitable control units and accessories Dimensional drawing 911 1140 49 Control units 200 117 Telescopic pillar Telesmart TMA 30 16 LD 015 LD 014 134 TMA LD-034.000.004 LD-011.031.000 33 Connecting diagrams Benefits 85 Powerful and fast lifting TMA can only be operated with LD control units. Aesthetic design Standards EN 60335 UL 60950 60 Legend: S = stroke L = retracted length Technical data Rated push load Rated pull load Bending load Speed (full load to no load) Telescopic pillar version Stroke Retracted length Voltage Power Current Duty cycle: intermittent operation Duty cycle: short-time operation Ambient temperature Type of protection Protection class Type of control Weight * For details, please see bending load diagrams Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 Unit TMA N N Nm mm/s # of section mm mm V DC W A min. min. °C IP – – kg 1 000 0 up to 200* 35 to 55 3-section 500 640 24 168 7 1 min./9 min. N/A +5 to +40 20 SELV electrical 8,5 130 484 640 621 Hand switch Foot switch Desk switch Telescopic pillars DC versions Ordering key Performance diagrams Lifting speed (mm/s) Lifting speed (mm/s) 60 60 50 50 40 40 30 30 20 20 10 10 0 TMA 1 0 – 0 0 500 1 000 1 500 2 000 2 500 – 5 0 0 0 0 Type Color: Natural anodized coating Black anodized coating 5 6 Options: With flange for crossbar one side With flange for crossbar two sides No flange for crossbar 0 0 Telesmart TMA Telesmart TMA 0 500 1 000 1 500 2 000 Load (N) EWY 2CM 2CN 2 500 Load (N) Lifting speed 3-channel control Lifting speed 2-channel control Lifting speed (mm/s) Current consumption (A) 7 60 6 50 5 40 4 30 3 20 2 10 1 0 0 0 500 1 000 1 500 2 000 0 2 500 200 400 600 800 Load (N) 1 000 1 200 Accessories Load (N) Current-load diagram Lifting speed 4-channel control Cable 1,0 m with DIN8–plug Cable 1,5 m with DIN8–plug Cable 2,5 m with DIN8–plug Bending load diagrams Push load (N) Designation Order N° ZKA–306355–1000 ZKA–306355–1500 ZKA–306355–2500 M/0121741 M/0121726 M/0121742 Push load (N) 1 000 1 000 900 900 800 800 Overload range 700 Overload range 700 600 600 Ideal range Ideal range 500 500 400 400 300 300 200 200 100 100 0 0 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Load arm (mm) Load arm (mm) ® SKF is a registered trademark of the SKF Group Dynamic stress diagram on X axis with maximum lift* © SKF Group 2010 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. Dynamic stress diagram on Y axis with maximum lift* * The values given apply to single lifting pillars. With a stable table structure the ideal field of use can be enlarged. Printed in Sweden on environmentally friendly paper. PUB L5322,1691 EN · September 2010 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Telesmart TMD Telescopic pillars DC versions Suitable control units and accessories Dimensional drawing 911 1140 49 Control units 200 117 Telescopic pillar Telesmart TMD 30 16 LD 015 LD 014 134 TMD LD-034.000.004 33 LD-011.031.000 621 Hand switch Foot switch Desk switch 85 Powerful and fast lifting TMD can only be operated with LD control units. Aesthetic design Efficient retracted length ratio Standards EN 60335 60 UL 60950 Legend: S = stroke L = retracted length Technical data Rated push load Rated pull load Bending load Speed (full load to no load) Telescopic pillar version Stroke Retracted length Voltage Power Current Duty cycle: intermittent operation Duty cycle: short-time operation Ambient temperature Type of protection Protection class Type of control Weight * For details, please see bending load diagrams Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 Unit TMD N N Nm mm/s # of section mm mm V DC W A min. min. °C IP – – kg 800 0 up to 120* 35 to 60 3-section 700 550 24 168 7 1 min./9 min. N/A +5 to +40 20 SELV electrical 8,5 130 484 640 Benefits Telescopic pillars DC versions Ordering key Performance diagrams Lifting speed (mm/s) Lifting speed (mm/s) 60 60 50 50 40 40 30 30 20 20 10 10 0 TMD 1 0 – 0 0 500 1 000 1 500 2 000 2 500 – 7 0 0 0 0 Type Color: Natural anodized coating Black anodized coating 5 6 Options: With flange for crossbar one side With flange for crossbar two sides No flange for crossbar 0 0 Telesmart TMD Telesmart TMD 0 500 1 000 1 500 2 000 Load (N) EWY 2CM 2CN 2 500 Load (N) Lifting speed 3-channel control Lifting speed 2-channel control Current consumption (A) Lifting speed (mm/s) 7 60 6 50 5 40 4 30 3 20 2 10 1 0 0 0 500 1 000 1 500 2 000 2 500 0 200 400 600 800 1 000 1 200 Load (N) Load (N) Accessories Current-load diagram Lifting speed 4-channel control Cable 1,0 m with DIN8–plug Cable 1,5 m with DIN8–plug Cable 2,5 m with DIN8–plug Bending load diagrams Push load (N) Designation Order N° ZKA–306355–1000 ZKA–306355–1500 ZKA–306355–2500 M/0121741 M/0121726 M/0121742 Push load (N) 800 800 700 700 600 600 Overload range Overload range 500 500 Ideal range Ideal range 400 400 300 300 200 200 100 100 0 0 0 100 200 300 400 0 Load arm (mm) 100 200 300 400 Load arm (mm) ® SKF is a registered trademark of the SKF Group Dynamic stress diagram on X axis with maximum lift* © SKF Group 2010 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. Dynamic stress diagram on Y axis with maximum lift* Printed in Sweden on environmentally friendly paper. * The values given apply to single lifting pillars. With a stable table structure the ideal field of use can be enlarged. PUB L5322,1692 EN · September 2010 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Telemag CPI Telescopic pillars DC versions Dimensional drawing 4 x M8 S S 4 x M8 197 181,8 5 16 9,6 14 5 16 45 1 9,2 12 197 17 161,2 7 4 x M8 S Suitable control units and accessories 40 Telescopic pillar L=S + 150 L=S + 150 L=S + 150 80 BCU 8 BCU 5 VCU 9 VCU 8 VCU 5 SCU 9 LD SCU 1 Telemag CPI SCU 5 Control units 8 20 4 x M8 4 x M8 4 x M8 CPI 0,2 17 202,2 240 0,2 17 185 202,2 217 0,2 5 18 17 202,2 217 2-section 3-section 2- or 3-section with slots EHA 3 0 8,3 +0,3 STE 8™ LD-011.031.000 Legend: S = stroke L = retracted length Hand switch Foot switch Desk switch Push or pull load Connecting diagram T-slotted outer tube 24 V DC + 5V+ Standards GND 1,5K EN 60950–1 Limit switches UL 60950–1 1+7 2+4 Blue Red 1,5K Hall A Hall B DIN8 plug IEC 60950–1 3 5 6 8 2 Hallsensors signal M Actuator % & Option & Technical data Max. push force Max. pull force Dynamic bending moment (2-section) Dynamic bending moment (3-section) Speed (full load) Speed (no load) Stroke Retracted length Voltage Power Current Duty cycle: intermittent operation Ambient temperature Type of protection Protection class Type of control Weight (2-section) (3-section) Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 ,5 R0 (4.15) 0 16,5 +0,5 Fast movement Robust and stable design (11) 15,5±0,3 LD-034.000.004 Benefits 0 6,9 +0,4 R0,5 R0,5 Unit CPI10-D CPI10-E CPI10-F N N Nm Nm mm/s mm/s mm mm V DC W A min. °C IP – – kg 1 000 1 000 250 max. 1 000 31 38 200 to 700 S+150 24 91,2 3,8 2 min./8 min. +10 to +40 30 III/SELV electrical 13 to 30 14 to 34 1 500 1 500 250 max. 1 000 22 28 200 to 700 S+150 24 96 4 2 min./8 min. +10 to +40 30 III/SELV electrical 13 to 30 14 to 34 4 000 4 000 250 max. 1 000 11 17 200 to 700 S+150 24 144 6 1 min./9 min. +10 to +40 30 III/SELV electrical 13 to 30 14 to 34 0 7,5 +0,3 STJ Telescopic pillars DC versions Telemag CPI Telemag CPI Ordering key Performance diagrams C P I 1 0 – T 0 – 0 0 0 Type 60 6 50 5 40 4 30 3 20 2 10 1 Voltage: 24 V DC Load: Push (N) 1 000 1 500 4 000 0 500 1 000 1 500 2 000 2 500 3 000 3 500 4 000 Speed-load diagram 0 500 1 000 1 500 2 000 2 500 3 000 3 500 4 000 Current-load diagram CPI10-D CPI10-E CPI10-F D E F 2 3 4 5 Stroke (S): 200 mm 250 mm 300 mm 350 mm 400 mm 450 mm 500 mm 550 mm 600 mm 650 mm 700 mm Other stroke lengths CPI10-D CPI10-E CPI10-F Bending load diagrams 200 250 300 350 400 450 500 550 600 650 700 XXX Electrical options: None 2-Hall encoder Lifetime monitoring 2-Hall encoder and lifetime monitoring 1 000 4 000 Speed (mm/s) 31 22 11 Tube set: 2-section 3-section 2-section T-slotted outer tube 3-section T-slotted outer tube 0 0 Pull (N) 1 000 1 500 4 000 0 F M N Cable through option: None Mains cable feedthrough, protection class I (retracted length +30 mm) max 250 V AC, max 10 A 3 000 Special: None Back-up nut (only for 4 000 N version) 500 2 000 0 C CPI 10-F CPI 10-E 0 B CPI 10-D 1 000 Options shown in italics are only available on demand. Contact SKF for more information on minimum quantities and additional costs. 0 0 0 100 200 300 400 0 500 100 200 300 400 500 600 700 800 900 1 000 Accessories Load diagram 2-section Load diagram 3-section CPI10-D 1 500 4 000 Top mounting plate (without T-slot), Bore 202,2™170,2 mm Top mounting plate (with T-slot), Bore 202,2™170,2 Bottom mounting plate 3-section, Bore 161,2™129,2 mm Bottom mounting plate 2-section, Bore 181,8™149,6 mm Screw for bottom mounting plates M10™25 (1 screw required) Screw for top mounting plates M8™35 (4 screws required) Screws for bottom mounting plates M8™35 (4 screws required) Motor cable 2xDIN8, 1 000 mm, black Motor cable 2xDIN8, 1 500 mm, black Motor cable 2xDIN8, 2 500 mm, black 3 000 1 000 2 000 500 1 000 0 0 0 100 200 300 400 500 600 700 800 900 1 000 0 100 200 300 400 500 600 700 800 Designation Order N° ZBE–333426 ZBE–333434 ZBE–333428 ZBE–333427 ZBE–510978 ZBE–530564 ZBE–530564 ZKA–306009–1000 ZKA–306009–1500 ZKA–306009–2500 M/0126542 M/0126543 M/0126541 M/0126540 M/0125359 M/0126539 M/0126539 M/0105471 M/0105472 M/0105473 ® SKF and Telemag are registered trademarks of the SKF Group 900 1 000 © SKF Group 2011 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. Load diagram 3-section CPI10-E Load diagram 3-section CPI10-F Printed in Sweden on environmentally friendly paper. PUB MT/P8 10236 EN · Febryary 2011 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk For ophthalmic equipment CPMA Telescopic pillars Dimensional drawing Suitable operating devices STK01-UW3000-X100 215 CPMA1-1 (4x) †9 16 180 0 CPMA2-2 4 13 18 160 8 0 CPMA1-2 4 Telescopic pillar 140 120 140 120 52 STK01-SW3000-X100 STL01-GW1000-X100 The outlet socket box can be used as a mounting plate. EHA41-13N00N-000 External power supply 24 V DC Operating device (4x) †9 Stroke ±2 Hand switch Foot switch Desk switch For ophthalmic equipment CPMA Benefits 24 V DC + 100-240 V AC L - N PE Retracted length ±2 Connecting diagrams PE Operating device Universal power supply Operating device Plug and play (4x) †9 16 18 0 16 Soft start and stop control 1 13 120 140 8 205,5 4 44 Multiple outlet socket accessories Cable through pillar M M The 2 socket boxes and the mounting plate could be used Standards on the inner and outer tube. IEC 60601-1:2005 (3rd edition) compliant Technical data Unit CPMA1-1 CPMA1-2 CPMA2-2 Rated push load (with self locking) Rated pull load Bending moment (dynamic) N N Nm 1 000 0 up to 115* 2 000 0 up to 250* 2 000 0 up to 250* Speed (full load to no load) Telescopic pillar version Stroke mm/s # of section mm 14 to 15 2-section 230 to 400 11 to 15 2-section 230 to 400 11 to 15 2-section 200 to 400 Retracted length Static Load (Max) in push way Static bending moment (Max) mm N Nm S+160 8 000 500 S+160 8 000 500 S+160 8 000 500 Voltage (rated) Input current (rated) Duty cycle: intermittent operation V A on/off 100–240 AC 50/60 Hz 1,5 1 min./9 min. 100–240 AC 50/60 Hz 1,6 1 min./9 min. 24 DC 5 1 min./9 min. Ambient temperature Type of protection Protection class °C IP – +10 to +40 30 I +10 to +40 30 I +10 to +40 30 – Type of control Noise level (Max) Weight Stand by power (Max) – dB(A) kg W electrical 45 8 to 11 1 electrical 45 9 to 12 1 electrical 45 8 to 11 – * For details, see offset load diagrams Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 0 Telescopic pillars For ophthalmic equipment CPMA Offset load diagram CPMA1-1 Offset load diagram CPMA1-2 and CPMA2-2 Speed-load diagram Load [N] Load [N] Speed [mm/s] 1 000 2 000 20 900 1 800 18 800 1 600 16 700 12 1 000 10 400 800 8 Underload n rrange 400 100 100 200 300 100 200 1 000 0 300 Load distance from the center of the pillar [mm] Offset load at full extension in the best axis Only for AC version 1 2 2 Stroke length (mm) Only for DC version 200 230 250 300 400 Other per 10 mm from 200 mm or 230 mm for AC version up to 400 mm 0 0 Load distance from the center of the pillar [mm] – 000 1 2 Tube set 2-section 2 0 0 2 4 200 0 Load: Push (N) 1 000 2 000 CPMA1-2 CPMA2-2 6 600 Underload d range g 200 Voltage 100–240 V AC 50/60 Hz 24 V DC 14 Overload range Ideal range g 500 300 – Type CPMA1-1 1 200 Ideal range g Ordering key C PMA 1 400 Overload range 600 For ophthalmic equipment CPMA 2 000 Load [N] Offset load at full extension in the best axis Motor orientation* Motor in inner tube Motor in outer tube More flexibility with Series CPMA design options Built-in with outer tube on top Built-in with outer tube on bottom More hygienic and easy-to-clean design More aesthetic design M A B Operating device orientation Operating device socket as the motor Operating device socket at both sides LAN cable through No LAN cable through M A B 0 1 Not compatible with op. device socket at both sides *Pillar can be placed with outer tube on the top or bottom (please refer to page 3) M M Motor orientation B Motor orientation A Accessories Description Plug Country Part number Mains cable straight 2,5 m Schuko Typ-L British standard NEMA SEV AS 3112 Germany, France, ... Italy UK USA, Japan, … CH PRC, Australia, ... ZKA-140449-2500 ZKA-140450-2500 ZKA-140451-2500 ZKA-140452-2500 ZKA-140458-2500 ZKA-140460-2500 Detachable mains cord straight 2,5 m (to plug in socket box Inlet) Schuko Typ-L British standard NEMA SEV AS 3112 Germany, France, ... Italy UK USA, Japan, … CH PRC, Australia, ... ZKA-140453-2500 ZKA-140454-2500 ZKA-140455-2500 ZKA-140456-2500 ZKA-140459-2500 ZKA-140461-2500 M Fixing armatures available as accessory 11 C-C 2:1 ) ax M h) h gt pt ) de len in M -in ead h ew Thr pt cr ( de 5 7. -in ew cr (S 6 Stroke ±2 (S 133 (4× M6 ) × 4× 93 M 6 C C RJ45 Operating device location Retracted length = (Stroke + 160) ±2 Mains power connection (Terminal block) RJ 45 LAN location (S ) ax M h) h gt pt ) de len in M -in ead h ew Thr pt cr ( de 5 7. -in ew cr (S 6 121 Mains power connection (Terminal block) M6 ) M 6 81 (4× Mounting plate ZPL-348382 Socket box inlet: IEC, RJ45 LAN, RJ45 op. device Socket box outlet: 3xIEC, RJ45 LAN, RJ45 op. device ZDV-348220-002 ZDV-348221-002 © SKF Group 2013 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. × D 109,5 124,5 STK01-SW3000-X100 STK01-UW3000-X100 EHA41-13N00N-000 STL01-GW1000-X100 ® SKF is a registered trademark of the SKF Group. 4× RJ45 operating device location 149,5 164,5 11 D-D 2:1 RJ 45 LAN location Desk switch with LED, cable 0,5 m Desk switch with LED, cable 1,0 m Handset with LED, cable coiled 1,3 m Foot switch, cable coiled 1,3 m D Pillar mustt be attached on plane and rigid surface by 4 screws M6 with a depth of 6 to 11 mm in the pillar. The total length of the screw mustt be adjusted to the height of the fixture. PUB MT/P8 13274 EN · March 2013 3 skf.com Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk For infant care CPMB Telescopic pillars Dimensional drawing drawing Suitable operating devices STK01-UW3000-X100 215 CPMB1-1 (4x) †9 16 180 0 CPMB2-2 4 13 18 160 8 0 CPMB1-2 4 Telescopic pillar 140 120 140 120 52 STK01-SW3000-X100 STL01-GW1000-X100 The outlet socket box can be used as a mounting plate. EHA41-13N00N-000 External power supply 24 V DC Operating device (4x) †9 Stroke ±2 Hand switch Foot switch Desk switch For infant care CPMB Benefits 24 V DC + 100-240 V AC L - N PE Retracted length ±2 Connecting diagrams PE Operating device Universal power supply Operating device Plug and play (4x) †9 16 18 0 16 Soft start and stop control 1 13 120 140 8 205,5 4 44 Low noise level Cable through pillar M M Grounding continuity The 2 socket boxes and the mounting plate could be used on the inner and outer tube. Standards IEC 60601-1:2005 (3rd edition) compliant Technical data Unit CPMB1-1 CPMB1-2 CPMB2-2 Rated push load (with self locking) Rated pull load Bending moment (dynamic) N N Nm 1 000 0 up to 115* 2 000 0 up to 250* 2 000 0 up to 250* Speed (full load to no load) Telescopic pillar version Stroke mm/s # of section mm 14 to 15 2-section 230 to 400 11 to 15 2-section 230 to 400 11 to 15 2-section 200 to 400 Retracted length Static Load (Max) in push way Static bending moment (Max) mm N Nm S+160 8 000 500 S+160 8 000 500 S+160 8 000 500 Voltage (rated) Input current (rated) Duty cycle: intermittent operation V A on/off 100–240 AC 50/60 Hz 1,5 1 min./9 min. 100–240 AC 50/60 Hz 1,6 1 min./9 min. 24 DC 5 1 min./9 min. Ambient temperature Type of protection Protection class °C IP – +10 to +40 30 I +10 to +40 30 I +10 to +40 30 – Type of control Noise level (Max) Weight Stand by power (Max) – dB(A) kg W electrical 45 8 to 11 1 electrical 45 9 to 12 1 electrical 45 8 to 11 – * For details, see offset load diagrams Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 0 Telescopic pillars For infant care CPMB Offset load diagram CPMB1-1 Offset load diagram CPMB1-2 and CPMB2-2 Speed-load diagram Load [N] Load [N] Speed [mm/s] 1 000 2 000 20 900 1 800 18 800 1 600 16 700 12 1 000 10 400 800 8 Underload n rrange 400 100 100 200 300 100 200 1 000 0 300 Load distance from the center of the pillar [mm] Offset load at full extension in the best axis Only for AC version 1 2 2 Stroke length (mm) Only for DC version 200 230 250 300 400 Other per 10 mm from 200 mm or 230 mm for AC version up to 400 mm 0 0 Load distance from the center of the pillar [mm] 0 – 000 1 2 Tube set 2-section 2 0 0 2 4 200 0 Load: Push (N) 1 000 2 000 CPMB1-2 CPMB2-2 6 600 Underload d range g 200 Voltage 100–240 V AC 50/60 Hz 24 V DC 14 Overload range Ideal range g 500 300 – Type CPMB1-1 1 200 Ideal range g Ordering key C PMB 1 400 Overload range 600 For infant care CPMB 2 000 Load [N] Offset load at full extension in the best axis Motor orientation* Motor in inner tube Motor in outer tube More flexibility with Series CPMB design options Built-in with outer tube on top Built-in with outer tube on bottom More hygienic and easy-to-clean design More aesthetic design M A B Operating device orientation Operating device socket as the motor Operating device socket at both sides A B M *Pillar can be placed with outer tube on the top or bottom (please refer to page 3) M M Motor orientation B Motor orientation A Accessories Description Plug Country Part number Mains cable straight 2,5 m Schuko Typ-L British standard NEMA SEV AS 3112 Germany, France, ... Italy UK USA, Japan, … CH PRC, Australia, ... ZKA-140449-2500 ZKA-140450-2500 ZKA-140451-2500 ZKA-140452-2500 ZKA-140458-2500 ZKA-140460-2500 Detachable mains cord straight 2,5 m (to plug in socket box Inlet) Schuko Typ-L British standard NEMA SEV AS 3112 Germany, France, ... Italy UK USA, Japan, … CH PRC, Australia, ... ZKA-140453-2500 ZKA-140454-2500 ZKA-140455-2500 ZKA-140456-2500 ZKA-140459-2500 ZKA-140461-2500 M Fixing armatures available as accessory 11 C-C 2:1 ) ax M h) h gt pt ) de len in d M - in ea h ew Thr pt cr ( de 5 7. - in ew cr (S 6 Stroke ±2 (S 133 (4× M6 ) × 4× 93 M 6 C C RJ45 Operating device location D-D 2:1 (S ew cr ) ax M h) h gt pt ) de len in d M h ea pt hr (T de -in ew cr (S Mains power connection (Terminal block) M 6 81 M6 ) STK01-SW3000-X100 STK01-UW3000-X100 EHA41-13N00N-000 STL01-GW1000-X100 Mounting plate ZPL-348382 Socket box inlet: IEC, RJ45 LAN, RJ45 op. device Socket box outlet: 3xIEC, RJ45 LAN, RJ45 op. device ZDV-348220-002 ZDV-348221-002 4× ® SKF is a registered trademark of the SKF Group. © SKF Group 2013 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. × D 109,5 124,5 Desk switch with LED, cable 0,5 m Desk switch with LED, cable 1,0 m Handset with LED, cable coiled 1,3 m Foot switch, cable coiled 1,3 m - in 5 6 7. 121 (4× RJ45 operating device location 149,5 164,5 11 Retracted length = (Stroke + 160) ±2 Mains power connection (Terminal block) D Pillar mustt be attached on plane and rigid surface by 4 screws M6 with a depth of 6 to 11 mm in the pillar. The total length of the screw mustt be adjusted to the height of the fixture. PUB MT/P8 13275 EN · March 2013 3 skf.com Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk For medical procedure equipment CPMT Telescopic pillar Suitable control units and operating devices SCU 5 SCU 9 VCU 5 VCU 8 VCU 9 BCU 5* BCU 8* CPMT l l l l l l l l EHA l l l l l l l l STJ l l l l l l l l 220 200 1 101 70 190 01 1 15 SCU 1 SKF Telescopic pillar Dimensional drawing †10,5 †22 †20 †15 Hand switch Foot switch For medical procedure equipment – series CPMT 4x M10/30 40 Nm Stroke ±2 EHA is hand switch STJ is foot switch STE is desk switch * Reduced load capacity: CPMT1-1 up tofor 3 000 N See old one symbols CPMT1-2 up to 4 000 N Connecting diagram 24–30 V DC + 5 V+ GND High stroke High load capacity High safety and reliability 1,5K Design flexibility Standards 1+7 2+4 Limit Blue switches Red 3 5 6 8 Pink Grey IEC 60601-1:2005 Max. Length 2 300 mm †22 1,5K Hall A Hall B DIN8 connector pins 4× M10/30 40 Nm 146 1 200 70 15 Low retracted height 129 6 14 3 16 Retracted length ±2 Benefits †11 †10,5 †11 146 90 1 220 Green Yellow 2-Hall sensor signal M ANSI/AAMI ES60601-1:2005 Actuator IEC 60601-1-2:2007 Technical data Unit CPMT1-1S CPMT1-1M CPMT1-2S CPMT1-2M Rated push load Rated pull load Static load (push)1) Safety factor on rated load2) Dynamic bending moment Static bending moment (max.) N N N 5 000 4 000 15 000 4 up to 4503) 1 000 5 000 4 000 15 000 4 up to 1 2003) 3 000 6 000 4 000 15 000 4 up to 5503) 1 000 6 000 4 000 15 000 4 up to 1 4003) 3 000 Retracted length Stroke (S) Speed Voltage Current (push, max.) Current (pull, max.) Duty cycle Ambient temperature IP protection Weight mm mm mm/s V DC A A on/off °C stroke/2 + 120 mm 400 to 600 14 to 34 24 to 30 12 10 1 min./9 min. +10 to +40 40 16,5 to 20 stroke/2 + 240 mm 300 to 600 14 to 34 24 to 30 12 10 1 min./9 min. +10 to +40 40 19 to 23,5 stroke/2 + 120 mm 400 to 600 12 to 26 24 to 30 10 7 1 min./9 min. +10 to +40 40 16,5 to 20 stroke/2 + 240 mm 300 to 600 12 to 26 24 to 30 10 7 1 min./9 min. +10 to +40 40 19 to 23,5 1) 2) 3) 2 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Nm Nm kg Compliant with static load according to IEC 60601-2-46:2010 Static tensile safety factor to prevent mechanical hazard according to IEC 60601-1:2005 For details, see offset load diagrams Telescopic pillar For medical procedure equipment CPMT Current diagram Mounting details Type key M10 101 Current [A] 14 12 12 101 35 Inner tube section base plate Base plate M10 Mounting plate (accessory) 10 MT 50 Outer tube section base plate 146 24–30 V DC CPM 30 1 000 2 000 3 000 4 000 5 000 6 000 Load [N] Stroke length (mm) 300 350 400 450 500 550 600 Other per 10 mm from 300 mm (or 400 mm for retracted length S) to 600 mm 2-Hall encoder, end limit switches SCU/VC 25 24 V U 15 15 10 10 5 5 0 0 1 000 2 000 3 000 4 000 5 000 6 000 Load [N] F Cable options 30 V 20 1 m DIN8 cable 2,3 m DIN8 cable 2,3 m flying leads cable 24 V 1 2 3 Additional attachment options Configuration options 0 1 000 2 000 3 000 4 000 5 000 Optional threads on outer tube section can be configured for additional attachment options. Please contact SKF for more details 6 000 Load [N] Choice in size and position High strength to support attached actuators Offset load diagram CPMT1-1S, -2S CPMT1-1M, -2M Load [N] 7 000 Load [N] 7 000 6 000 6 000 5 000 Only for retracted length M Only for retracted length M 30 30 V 0 S M Electrical options 25 20 0 1 2 Stroke/2 + 120 mm Stroke/2 + 240 mm 0 CPMT1-2 SCU / VCU 0 Retracted length 2 Speed [mm/s] 35 35 0 1 Push (N) Pull (N) 5 000 4 000 6 000 4 000 The pillar must be mounted on a plane and rigid surface by 4 screws M10 (accessory) with a screw in depth of 25 to 35 mm in the pillar. Speed [mm/s] – 0 Load 2 T1- 0 Speed-load diagram CPMT1-1 – CP 8 4 15 1 Voltage 1 1- 10 6 146 CPMT Type Option S Option M DIN8 or flying leads cable for connectorr flexibility Accessories Accessories Description Part number Description Part number Control Unit SCU (3 or 6 ports) Control Unit VCU (3 or 5 ports) Control Unit BCU (3 ports) SCUXX-003XXX-000 VCUXX-003XX0-000 BCUX3-XX3100-0000 Top mounting plate Bottom mounting plate Screw (4/plate) for mounting plate SPL-290268 SPL-290265 ZBE-510707 Foot switch STJ (1-3 channels) Hand switch EHA3 (1-5 channels) STJ0X-XXXXXX-XX00 EHA3X-23MXXN-000 5 000 overload overload 4 000 4 000 3 000 2 000 ideal CPM T12 3 000 S 2 000 S CPM T11 CPMT1-2 M CPMT1-1 M ideal 1 000 1 000 underload underload 0 ® SKF is a registered trademark of the SKF Group. 0 0 100 200 300 400 500 600 Load distance from the center of the pillar [mm] 0 100 © SKF Group 2014 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. 200 300 400 500 600 Load distance from the center of the pillar [mm] Offset load at full extension Offset load at full extension PUB MT/I4 13960 EN · February 2014 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk skf.com CAWA Telescopic pillars DC versions Dimensional drawing Connecting diagram 15 4 85 78 24 V DC + - 11 Telescopic pillar LS (provided by the customer) CAWA linear drive profile M Actuator 30 Benefits S+V+113 32 39 134 V Lubricated for service life High operating reliability Selection of front attachments Powerful Min. = V+50 / Max. = S+50 †12 65,5 Compact Legend: S = stroke L = retracted length V = carriage (295, 395 or 495 mm) Technical data Rated push load Rated pull load Speed (full load to no load) Telescopic pillar version Stroke Retracted length Voltage Power Current Duty cycle: intermittent operation Ambient temperature Type of protection Protection class Type of control Weight Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 Unit CAWA N N mm/s #of section mm mm V DC W A min. °C IP – – kg 1 650 0 14 to 22 N/A 500 to 1 000 S+V+113+75 24 132 5,5 1 min./9 min. +5 to +40 20 SELV electrical 10 to 15 75 1 11 116 5 19 21 Telescopic pillars DC versions CAWA CAWA Ordering key Performance diagrams Current consumption (A) Speed (mm/s) 30 7 C AWA X 2 4 0 0 0 6 5 Type 4 Stroke (S): 50 mm 600 mm 700 mm 800 mm 900 mm 1 000 mm 20 3 10 2 1 0 0500 0600 0700 0800 0900 1000 0 0 500 1 000 1 650 0 500 Speed-load diagram 1 000 Carriage (V): 295 mm 395 mm 495 mm 1 650 Load (N) Load (N) 295 395 495 Current-load diagram Motor bracket: Yes No K 0 Cover: Yes No F 0 Voltage (V DC): 24 ® SKF is a registered trademark of the SKF Group © SKF Group 2010 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. Printed in Sweden on environmentally friendly paper. PUB MT/P8 10824 EN · May 2010 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk TMS Telescopic pillars no motor 0,5 x stroke + 176 Dimensional drawing Telescopic pillar 1,5 x stroke + 176 TMS 670 0 20 Benefits H Sta 670 E 20 U Legend: S = stroke L = retracted length Technical data Push load Pull load Speed Stroke Retracted length Duty cycle: intermittent operation Duty cycle: short-time operation Ambient temperature Weight Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk Unit TMS 00 N N mm/s mm mm min. min. °C kg 4 000 4 000 N/A 250 to 700 S ™ 0,5 + 176 1 min./9 min. N/A +10 to +40 61 to 82 0 Telescopic pillars no motor TMS TMS Ordering key Performance diagrams Speed (mm/s) Motor torque (Nm) 20 0,4 15 0,3 10 0,2 5 0,1 TMS 0 0 – 0 0 0 0 0 0 – 0 0 Type 0 0 0 1 500 3 000 4 500 6 000 0 1 000 2 000 Rotation (rpm) Speed-rotational diagram 3 000 4 000 Load (N) Stroke (S): 250 mm 300 mm 350 mm 400 mm 450 mm 500 mm 550 mm 600 mm 650 mm 700 mm 250 300 350 400 450 500 550 600 650 700 Torque-load diagram Options written in italic fonts are only available on demand. Please contact SKF Bending load diagram Push load (N) 5 000 4 500 In main load direction X 4 000 3 500 3 000 Ideal range 2 500 2 000 1 500 1 000 Minimum load 500 0 0 500 1 000 1 500 2 000 Loading arm (mm) ® SKF is a registered trademark of the SKF Group © SKF Group 2009 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. Printed in Sweden on environmentally friendly paper. PUB L5322,4100 EN · October 2009 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk FRE Telescopic pillars no motor Dimensional drawings B B Telescopic pillar 8 22 B 20 22 +10 B FRE 22 +10 20 30 Benefits Attractive design A 86±0,3 85±0,2 A A 4xM6 129 146±0,45 Universal use A 163±0,4 M5 72±0,3 A 97±0,2 Stable M10 M5 146 59,3±0,2 M10 A 146±0,2 76±0,2 4xM5 76±0,2 123,7±0,4 B 102,5 59±0,2 A A 69 M6 B 113 M6 FRE–A085 FRE–A113 FRE–A146 FRE–D097 FRE–D129 FRE–D163 FRE–B097 FRE–B129 FRE–B163 FRE–E113 FRE–E146 Options written in italic fonts are only available on demand. Please contact SKF Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk 2 163 ™ 163 146 ™ 146 129 ™ 129 113 ™ 113 Retracted length in mm 97 ™ 97 85 ™ 85 76 ™ 76 Profile dimensions in mm 3 sections Sections 2 sections Type B B Stroke + 138 Stroke + 148 Stroke + 168 Stroke + 38 Stroke + 53 Stroke + 53 N/A N/A N/A N/A N/A Telescopic pillars no motor FRE The Power of Knowledge Engineering Seals Ordering key Bearings and units Mechatronics F R E – – Lubrication systems Services Drawing on five areas of competence and application-specific expertise amassed over more than 100 years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics (combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D computer modelling to advanced condition monitoring and reliability and asset management systems. A global presence provides SKF customers uniform quality standards and worldwide product availability. – 0 0 0 Type Combination: 2 sections tube-set /Largest tube size 85™85 mm 113™113 mm 146™146 mm 97™97 mm 129™129 mm 163™163 mm 3 sections tube-set /Largest tube size 97™97 mm 129™129 mm 163™163 mm 113™113 mm 146™146 mm 4 sections tube-set (on request) 5 sections tube-set (on request) 6 sections tube-set (on request) 7 sections tube-set (on request) Color: Natural anodized Black anodized Option: No option Cover Pull version Pull version, with cover Stroke: 200 mm 300 mm 400 mm 500 mm 600 mm 700 mm Other stroke lengths A085 A113 A146 B097 B129 B163 D097 D129 D163 E113 E146 V_ F_ S_ Z_ 5 6 000 MCM MCN 2EA 20 30 40 50 60 70 --- Options written in italic fonts are only available on demand. Please contact SKF ® SKF is a registered trademark of the SKF Group © SKF Group 2010 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein. PUB MT/P8 10982 EN · August 2010 Printed in Sweden on environmentally friendly paper. 3 Electro Mechanical Systems Limited tel: 0118 981 7391 [email protected] www.ems-limited.co.uk