IMPELLER CENTRIFUGAL PUMPS TYPE KS
Impeller centrifugal KS pumps have been designer to pump some acid, lye, hydrocarbon
and other chemically active fluids, with hydrogen ionic concentration pH>3,5. With
KS pumps it is possible to pump liquids with viscosity up to 200 mm2/s and density
up to 1900 kg/m3.
The temperature of the fluid cannot exceed 120 OC. Abrasive bodies content (grain size
not bigger than 1 mm) should be limited to 50 mg/dm3. Gauge pressure of the fluid at
the inlet to the pump most not exceed 1,0 Mpa.
Basic technical data
Output Q Lift Hmax Rotation Speer Temperature Shaft sealing max.72m3/h
max.55 m
1450 rpm (50Hz) and 1800 rpm (60Hz)
2900 rpm (50 Hz) and 3600 rpm (60 Hz)
max.120 OC,
string and face seal
IMPELLER CENTRIFUGAL
UNI-BLOCK PUMPS TYPE KSM
Impeller, centrifugal uni-block KS pumps have been designer to pump some acid, lye, hydrocarbon and other chemically active fluids, with hydrogen ionic concentration pH>3,5.
With KS pumps it is possible to pump liquids with viscosity up to 200 mm2/s and density
up to 1900 kg/m3.
The temperature of the fluid cannot exceed 70 OC. Abrasive bodies content (grain size not
bigger than 1 mm) should be limited to 50 mg/dm3. Gauge pressure of the fluid at the
inlet to the pump most not exceed 1,0 Mpa.
Basic technical data
Output Q Lift Hmax Rotation Speer Temperature Shaft sealing max.72m3/h
max.55 m
1450 rpm (50Hz) and 1800 rpm (60Hz)
2900 rpm (50 Hz) and 3600 rpm (60 Hz)
max. 70 OC,
face seal
Construction materials of KS and KSM pumps
Materials applied in KS and KSM pumps
Part name
Pump casing
Bearing casing
Impeller
Shaft
Packing bush*
Shaft seal
1
grey cast iron
grey cast iron
chromium cast iron
Carbon steel
chromium cast iron
Construction materials „d”
2
3
4
5
chromium cast iron
tin bronze
cast carbon steel asid resistant cast steel
grey cast iron
grey cast iron
grey cast iron
grey cast iron
chromium cast iron
tin bronze
cast carbon steel asid resistant cast steel
acid resistant steel acid resistant steel acid resistant steel
acid resistant steel
chromium cast iron acid resistant steel acid resistant steel
acid resistant steel
soft sealing cord ** - mechanical ***
*) KSM pumps have no gland sleeve
**) KSM pumps have only mechanical seals
***) The selection of the pump depends on the type of the liquid
ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska
tel. +48(56) 45 07 410; fax: +48(56) 46 25 955
2
www.hv.pl
[email protected]
GEN ER AL I N FOR M AT ION
Design variants of KS and KSM pumps
Variant no
1010
1020
1100
1110
1120
1130
1140
1140
1150
1130
1160
1170
1310
1400
1410
Variant name
KS
The pump with string seal for liquids
with temp. -30 OC ÷ +70 OC
The pump with string seal and cooling chamber for liquids
with temp. +70 OC ÷ + 120 OC
The pump with single, face seal type A1
The pump with single, face seal type V
The pump with single, face seal type A10
The pump with single, face seal type UV
The pump with single, face seal type US
The pump with single, face seal type US2
The pump with single, face seal type A4
Pump with double end-face seal, in BACK TO BACK system
of V + V type (barrier liquid required)
Pump with single end-face seal of 2100 type
Pump with single end-face seal of 58U type
Pump with double end-face seal, in BACK TO BACK system
of 58U + 58U type (barrier liquid required)
Pump with double compact seal of BED type
(barrier/buffer liquid required)
Pump with double compact seal of BED type
with barrier/buffer liquid installation
X
KSM
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Pump section, type KS
1 - Jointing member
2 - Sealing cover
3 - Bearing casing
4 - Pump housing
5 - Impeller
6 - Sealing casing
7 - Shaft sealing
8 - Sealing bush
9 - Shaft
Pump section, type KSM
1 - Sealing cover
2 - Shaft
3 - Motor
4 - Pump sealing
5 - Impeller
6 - Sealing casing
7 - Shaft sealing
8 - Jointing member
www.hv.pl
[email protected]
ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska
tel. +48(56) 45 07 410; fax: +48(56) 46 25 955
3
CH AR ACTER IST ICS
The characteristics of the KS.5, KSM.5 pumps
f = 50 Hz
n= 2 900 rpm
Q Output [m3/h]
P - Power [kW]
P - Power [kW]
Q Output [m3/h]
Q Output [m3/h]
NPSHr [m]
NPSHr [m]
Q Output [m3/h]
Q Output [m3/h]
Q Output [m3/h]
The characteristics of the KS.7, KSM.7 pumps
f = 50 Hz
n= 2 900 rpm
f = 50 Hz
n= 1 450 rpm
H Lift [m]
H Lift [m]
The characteristics of the KS.7, KSM.7 pumps
Q Output [m3/h]
P - Power [kW]
P - Power [kW]
Q Output [m3/h]
Q Output [m3/h]
NPSHr [m]
NPSHr [m]
Q Output [m3/h]
Q Output [m3/h]
Description of the characteristic:
H[m] - H the lift
NPSHr[m] - net positive suction head
Q Output [m3/h]
P[kW] - Power of one stage
Q[m3/h] - Q Output
ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska
tel. +48(56) 45 07 410; fax: +48(56) 46 25 955
4
f = 50 Hz
n= 1 450 rpm
H Lift [m]
H Lift [m]
The characteristics of the KS.5, KSM.5 pumps
www.hv.pl
[email protected]
PUMP DIMENSIONS
Dimensions of KS pumps
Dimensions of fundation plates
Part No
60.36.01.1
60.37.01.1
60.37.02.1
60.38.01.1
60.39.01.1
60.40.01.1
60.40.03.1
Pump
DN1 DN2 e1 e2 f 1 f 2 N1 N2 g1 g2 h i
k m
type
KS.5. 65 50 145 125 185 165 8 4
100 180 513
18 18 160
KS.7. 80 65 160 145 200 185 8 8
125 200 516
N1,N2 - number of holes in the connection flanges (suction discharge)
A
615
657
657
743
802
910
910
B
190
205
205
205
205
205
205
B1
217
279
279
310
342
417
417
C
145
150
150
150
150
150
150
C2
430
460
460
550
520
460
460
D
140
160
160
160
160
160
160
D1
290
390
390
F
14
14
14
14
14
14
14
I
3
3
3
3
4
4
4
l - number of holes for foundation bolt
* - C2 dimension for 4 holes
** - C2 dimension for 3 holes
*** - The 1020 constructional execution only concerns
Selection and dimension of KS pumping units
Selection and dimensions of KS pumps (1450 rpm)
Completeness
Pump
size
KS5.1
KS7.1
1
2
3
5
Pump weight
free
shaft
end
with
coupling
58
58
58
58
58
62
62
62
62
62
62
59,5
59,5
59,5
59,5
61
63,5
63,5
63,5
63,5
65
65
with
coupling
and plate
with coupling, plate
and motor
84,5
84,5
82
82
82
88,5
88,5
86
86
86
86
102
103,5
107,5
112
119
105,5
107,5
11,5
116,5
123
130
kg
Motor
Foundation plate
Assembly outline dimension
Coupling
type
E3
E3
E3
E7
E7
E3
E3
E3
E7
E7
E7
Mechanical
size
Power
plate
block
KW
number
804B
90S4
90L4
100L4A
100L4B
804B
90S4
90L4
100L4A
100L4B
112M4
0,75
1,1
1,5
2,2
3,0
0,75
1,1
1,5
2,2
3,0
4,0
60.36.01.1 68.40.03.1
60.36.01.1
60.36.01.1
60.37.01.1
60.37.01.1
60.36.01.1 68.40.03.1
60.36.01.1
60.36.01.1
60.37.01.1
60.37.01.1
60.37.02.1
-
P
H
278
278
278
278
278
306
306
306
306
306
306
400
400
400
400
400
420
420
420
420
420
420
M
L
220
220
220
280
280
220
220
220
280
280
280
930
945
975
1005
1015
955
970
1000
1030
1040
1070
mm
Selection and dimensions of KS pumps (2900 rpm)
Completeness
Pump
size
KS5.1
KS7.2
www.hv.pl
[email protected]
1
2
3
5
Pump weight
free
shaft
end
with
coupling
58
58
58
58
58
58
58
62
62
62
62
62
62
62
62
59,5
61
61
61
62
67
67
65
65
65
66
71
71
73,3
73,3
with
coupling
and plate
with coupling, plate
and motor
82
82
82
87
88
104
104
86
86
91
92
108
108
118,3
120,3
108
116,5
122
144
149
197
212
117,5
126
145
153
201
216
235,3
261,3
kg
Motor
Foundation plate
Assembly outline dimension
Coupling
type
E3
E7
E7
E9
E9
E10
E10
E7
E7
E9
E9
E10
E10
E10
140A
Mechanical
size
Power
90L2
100L2
112M2
132S2A
132S2B
160M2A
160M2B
100L2
112M2
132S2A
132S2B
160M2A
160M2B
160L2
180M2
2,2
3,0
4,0
5,5
7,5
11,0
15,0
3,0
4,0
5,5
7,5
11,0
15,0
18,5
22,0
KW
plate
block
P
H
278
278
278
278
278
278
278
306
306
306
306
306
306
306
306
400
400
400
400
400
400
400
420
420
420
420
420
420
450
470
number
60.36.01.1
60.37.01.1
60.37.02.1
60.38.01.1
60.38.01.1
60.40.03.1
60.40.03.1
60.37.01.1
60.37.02.1
60.38.01.1
60.38.01.1
60.40.03.1
60.40.03.1
60.40.03.1
60.40.01.1
M
L
220
280
280
310
310
345
345
280
280
310
310
345
345
420
420
1005
1005
1045
1084
1124
1096
1116
1040
1070
1109
1144
1116
1189
1264
1312
mm
-
ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska
tel. +48(56) 45 07 410; fax: +48(56) 46 25 955
5
PUMP DIMENSIONS
Dimension of KSM pumps
The pumping units
with motor power up to 3 kW
SKg90L-4/FF165
SKg80-4A/FT165
SKg90L-2/FF165
SKg100L-2/FT165
SLg112M-2/FT165
SKg132S-2A/FT165
SLg1132-2B/FT165
SLg160M-2A/FF300
SLg160M-2B/FF300
SKg80-4A/FF165
SKg80-4B/FF165
SKg90S-4/FF165
SKg90L-4/FF165
SKg100l-4A/FT165
SKg100L-2/FT165
SLg112m-2/FT165
SKg132S-2A/FT165
SLg132S-2B/FT165
SLg160M-2A/FF300
SLG160M-2B/FF300
KSM7.2
SKg90S-4/FF165
KSM7.1
SKg80-4B/FF165
Power (kW)
rpm min-1
DN1**
DN 2**
a**
b1**
b 2**
b 3**
d1**
d2**
d3**
d4**
d5**
d 6**
d7**
d8**
N1**
N 2**
h1**
h 2**
h 3**
h 4**
i**
l1**
l2**
m1**
m2**
n 3**
n 4**
s**
w**
Weight (kg)
KSM5.1
SKg80-4A/FF165
Motor type
KSM5.1
The pumping units
with motor power over 4 kW
0,55
1450
65
50
100
140
142
200
157
145
125
185
165
18
8
4
160
180
135
106
533
362
200
51,0
0,75
1450
65
50
100
140
142
200
157
145
125
185
165
18
8
4
160
180
135
106
533
362
200
52,0
1,10
1450
65
50
100
140
142
200
175
145
125
185
165
18
8
4
160
180
135
106
556
385
200
58,0
1,50
1450
65
50
100
140
142
200
175
145
125
185
165
18
8
4
160
180
135
106
581
410
200
61,5
2,20
1450
65
50
100
140
142
200
205
145
125
185
165
18
8
4
160
180
135
106
614
443
200
70,5
2,20
2900
65
50
100
140
142
200
175
145
125
185
165
18
8
4
160
180
135
106
581
410
200
62,5
3,00
2900
65
50
100
140
142
200
205
145
125
185
165
18
8
4
160
180
135
106
614
443
200
72,0
4,00
2900
65
50
100
54
140
142
12
200
231
145
125
185
165
18
8
4
180
135
112
270
624
172
140
246
190
15
200
75,0
5,50
2900
65
50
100
71
140
142
12
200
263
145
125
185
165
18
8
4
180
135
132
289
683
180
140
274
216
18
200
98,5
7,50
2900
65
50
100
71
140
142
12
20
263
145
125
185
165
18
8
4
180
135
132
289
721
180
140
274
216
18
200
106,5
11,00
2900
65
50
100
60
140
142
15
350
323
145
125
185
165
18
8
4
180
135
160
338
832
250
210
300
254
20
230
148,5
15,00
2900
65
50
100
60
140
142
15
350
323
145
125
185
165
18
8
4
180
135
160
338
832
250
210
300
254
20
230
164,5
0,55
1450
80
65
125
140
152
200
157
160
145
200
185
18
8
8
160
200
145
109
543
344
203
64,5
0,75
1450
80
65
125
140
152
200
157
160
145
200
185
18
8
8
160
200
145
109
560
361
203
65,5
1,10
1450
80
65
125
140
152
200
175
160
145
200
185
18
8
8
160
200
145
109
583
384
203
71,0
1,50
1450
80
65
125
140
152
200
175
160
145
200
185
18
8
8
160
200
145
109
608
409
203
72,5
2,20
1450
80
65
125
140
152
200
205
160
145
200
185
18
8
8
160
200
145
109
644
445
203
80,5
3,00
2900
80
65
125
140
152
200
205
160
145
200
185
18
8
8
160
200
145
109
644
445
203
82,0
4,00
2900
80
65
125
54
140
152
12
200
231
160
145
200
185
18
8
8
200
145
112
273
652
172
140
246
190
15
203
90,0
5,50
2900
80
65
125
71
140
152
12
200
263
160
145
200
185
18
8
8
200
145
132
292
688
180
140
274
216
18
203
113,0
7,50
2900
80
65
125
71
140
152
13
200
263
160
145
200
185
18
8
8
200
145
132
292
728
180
140
274
216
18
203
121,0
11,00
2900
80
65
125
60
140
152
15
350
323
160
145
200
185
18
8
8
200
145
160
341
868
250
210
300
254
20
233
156,0
15,00
2900
80
65
125
60
140
152
15
350
323
160
145
200
185
18
8
8
200
145
160
341
868
250
210
300
254
20
233
171,0
*) - the above dimensions have been taken from the catalogue of „Tamel” (the manufacturer of motors).
Data for motors of other manufacturers may differ.
**) - number of holes in the connection flanges (suction discharge)
ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska
tel. +48(56) 45 07 410; fax: +48(56) 46 25 955
6
www.hv.pl
[email protected]
GEN ER AL I N FOR M AT ION
Product symbol structure
The pump symbol consists the following elements:
where:
a a a
b
c c
d e e1 e1 e2
h
h
1
2
3
4
5
- produkt name (KS or KSM)
- pump size
- pump dimension (concerning the diameter of the impeller)
- material selection
- pump design
- delivery completeness, according to internal documents of the manufacturer
Variant name
The pump with free haf end
The pump with complete coupling
The pump with complete coupling, foundation bolts
and coupling cover on he foundation plate
Uni-block
Completeness 3 + motor
KS
X
X
KSM
X
X
X
Motor protection
To ensure smooth failure-free motor operation, it is necessary to install devices securing from:
w
w
w
w
poverload,
phase decay and feeding asymmetry,
symmetric decline of supply voltage,
excessive number of switches, dry run.
These functions are fulfilled by protection-control device of UZS type produced by Hydro-Vacuum S.A.
Single-phase motor pumping units are serially equipped
with a staring switch with built-in:
w unipolar switch,
w WEBER thermistor,
w start-work capacitor.
To ensure long life of the motor, it is recommended not to switch it more han 20 times an hour.
The switching on cycle should be not shorter than every 3 minutes.
Attestations and certificates
Attest no W/683/95 obtained from State Institute of Hygiene.
„Power Engineering Attest” obtained from the Ministry of Industry and Trade.
„B” safety mark, obtained from PCBC.
www.hv.pl
[email protected]
ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska
tel. +48(56) 45 07 410; fax: +48(56) 46 25 955
7
Hydro-Vacuum S.A.
w thousands of satisfied clients in Poland and abroad
w almost 150 years of experience
w designed, manufactured and sold millions of pumps
ul. Droga Jeziorna 8, 86-303 Grudziądz, Poland
tel. +48(56) 45 07 410, fax +48(56) 45 25 955
Export Department: tel. +48(56) 45 07 554 ; fax. +48(56) 45 07 346
www.hv.pl • [email protected]
Guaranteed satisfaction with the use of our products!