Impeller centrifugal pumps - type KS, KSM - Emet
Transcription
Impeller centrifugal pumps - type KS, KSM - Emet
Impeller centrifugal pumps - type KS, KSM GEN ER AL I N FOR M AT ION IMPELLER CENTRIFUGAL PUMPS TYPE KS Impeller centrifugal KS pumps have been designer to pump some acid, lye, hydrocarbon and other chemically active fluids, with hydrogen ionic concentration pH>3,5. With KS pumps it is possible to pump liquids with viscosity up to 200 mm2/s and density up to 1900 kg/m3. The temperature of the fluid cannot exceed 120 OC. Abrasive bodies content (grain size not bigger than 1 mm) should be limited to 50 mg/dm3. Gauge pressure of the fluid at the inlet to the pump most not exceed 1,0 Mpa. Basic technical data Output Q Lift Hmax Rotation Speer Temperature Shaft sealing max.72m3/h max.55 m 1450 rpm (50Hz) and 1800 rpm (60Hz) 2900 rpm (50 Hz) and 3600 rpm (60 Hz) max.120 OC, string and face seal IMPELLER CENTRIFUGAL UNI-BLOCK PUMPS TYPE KSM Impeller, centrifugal uni-block KS pumps have been designer to pump some acid, lye, hydrocarbon and other chemically active fluids, with hydrogen ionic concentration pH>3,5. With KS pumps it is possible to pump liquids with viscosity up to 200 mm2/s and density up to 1900 kg/m3. The temperature of the fluid cannot exceed 70 OC. Abrasive bodies content (grain size not bigger than 1 mm) should be limited to 50 mg/dm3. Gauge pressure of the fluid at the inlet to the pump most not exceed 1,0 Mpa. Basic technical data Output Q Lift Hmax Rotation Speer Temperature Shaft sealing max.72m3/h max.55 m 1450 rpm (50Hz) and 1800 rpm (60Hz) 2900 rpm (50 Hz) and 3600 rpm (60 Hz) max. 70 OC, face seal Construction materials of KS and KSM pumps Materials applied in KS and KSM pumps Part name Pump casing Bearing casing Impeller Shaft Packing bush* Shaft seal 1 grey cast iron grey cast iron chromium cast iron Carbon steel chromium cast iron Construction materials „d” 2 3 4 5 chromium cast iron tin bronze cast carbon steel asid resistant cast steel grey cast iron grey cast iron grey cast iron grey cast iron chromium cast iron tin bronze cast carbon steel asid resistant cast steel acid resistant steel acid resistant steel acid resistant steel acid resistant steel chromium cast iron acid resistant steel acid resistant steel acid resistant steel soft sealing cord ** - mechanical *** *) KSM pumps have no gland sleeve **) KSM pumps have only mechanical seals ***) The selection of the pump depends on the type of the liquid ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska tel. +48(56) 45 07 410; fax: +48(56) 46 25 955 2 www.hv.pl [email protected] GEN ER AL I N FOR M AT ION Design variants of KS and KSM pumps Variant no 1010 1020 1100 1110 1120 1130 1140 1140 1150 1130 1160 1170 1310 1400 1410 Variant name KS The pump with string seal for liquids with temp. -30 OC ÷ +70 OC The pump with string seal and cooling chamber for liquids with temp. +70 OC ÷ + 120 OC The pump with single, face seal type A1 The pump with single, face seal type V The pump with single, face seal type A10 The pump with single, face seal type UV The pump with single, face seal type US The pump with single, face seal type US2 The pump with single, face seal type A4 Pump with double end-face seal, in BACK TO BACK system of V + V type (barrier liquid required) Pump with single end-face seal of 2100 type Pump with single end-face seal of 58U type Pump with double end-face seal, in BACK TO BACK system of 58U + 58U type (barrier liquid required) Pump with double compact seal of BED type (barrier/buffer liquid required) Pump with double compact seal of BED type with barrier/buffer liquid installation X KSM X X X X X X X X X X X X X X X X X X X Pump section, type KS 1 - Jointing member 2 - Sealing cover 3 - Bearing casing 4 - Pump housing 5 - Impeller 6 - Sealing casing 7 - Shaft sealing 8 - Sealing bush 9 - Shaft Pump section, type KSM 1 - Sealing cover 2 - Shaft 3 - Motor 4 - Pump sealing 5 - Impeller 6 - Sealing casing 7 - Shaft sealing 8 - Jointing member www.hv.pl [email protected] ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska tel. +48(56) 45 07 410; fax: +48(56) 46 25 955 3 CH AR ACTER IST ICS The characteristics of the KS.5, KSM.5 pumps f = 50 Hz n= 2 900 rpm Q Output [m3/h] P - Power [kW] P - Power [kW] Q Output [m3/h] Q Output [m3/h] NPSHr [m] NPSHr [m] Q Output [m3/h] Q Output [m3/h] Q Output [m3/h] The characteristics of the KS.7, KSM.7 pumps f = 50 Hz n= 2 900 rpm f = 50 Hz n= 1 450 rpm H Lift [m] H Lift [m] The characteristics of the KS.7, KSM.7 pumps Q Output [m3/h] P - Power [kW] P - Power [kW] Q Output [m3/h] Q Output [m3/h] NPSHr [m] NPSHr [m] Q Output [m3/h] Q Output [m3/h] Description of the characteristic: H[m] - H the lift NPSHr[m] - net positive suction head Q Output [m3/h] P[kW] - Power of one stage Q[m3/h] - Q Output ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska tel. +48(56) 45 07 410; fax: +48(56) 46 25 955 4 f = 50 Hz n= 1 450 rpm H Lift [m] H Lift [m] The characteristics of the KS.5, KSM.5 pumps www.hv.pl [email protected] PUMP DIMENSIONS Dimensions of KS pumps Dimensions of fundation plates Part No 60.36.01.1 60.37.01.1 60.37.02.1 60.38.01.1 60.39.01.1 60.40.01.1 60.40.03.1 Pump DN1 DN2 e1 e2 f 1 f 2 N1 N2 g1 g2 h i k m type KS.5. 65 50 145 125 185 165 8 4 100 180 513 18 18 160 KS.7. 80 65 160 145 200 185 8 8 125 200 516 N1,N2 - number of holes in the connection flanges (suction discharge) A 615 657 657 743 802 910 910 B 190 205 205 205 205 205 205 B1 217 279 279 310 342 417 417 C 145 150 150 150 150 150 150 C2 430 460 460 550 520 460 460 D 140 160 160 160 160 160 160 D1 290 390 390 F 14 14 14 14 14 14 14 I 3 3 3 3 4 4 4 l - number of holes for foundation bolt * - C2 dimension for 4 holes ** - C2 dimension for 3 holes *** - The 1020 constructional execution only concerns Selection and dimension of KS pumping units Selection and dimensions of KS pumps (1450 rpm) Completeness Pump size KS5.1 KS7.1 1 2 3 5 Pump weight free shaft end with coupling 58 58 58 58 58 62 62 62 62 62 62 59,5 59,5 59,5 59,5 61 63,5 63,5 63,5 63,5 65 65 with coupling and plate with coupling, plate and motor 84,5 84,5 82 82 82 88,5 88,5 86 86 86 86 102 103,5 107,5 112 119 105,5 107,5 11,5 116,5 123 130 kg Motor Foundation plate Assembly outline dimension Coupling type E3 E3 E3 E7 E7 E3 E3 E3 E7 E7 E7 Mechanical size Power plate block KW number 804B 90S4 90L4 100L4A 100L4B 804B 90S4 90L4 100L4A 100L4B 112M4 0,75 1,1 1,5 2,2 3,0 0,75 1,1 1,5 2,2 3,0 4,0 60.36.01.1 68.40.03.1 60.36.01.1 60.36.01.1 60.37.01.1 60.37.01.1 60.36.01.1 68.40.03.1 60.36.01.1 60.36.01.1 60.37.01.1 60.37.01.1 60.37.02.1 - P H 278 278 278 278 278 306 306 306 306 306 306 400 400 400 400 400 420 420 420 420 420 420 M L 220 220 220 280 280 220 220 220 280 280 280 930 945 975 1005 1015 955 970 1000 1030 1040 1070 mm Selection and dimensions of KS pumps (2900 rpm) Completeness Pump size KS5.1 KS7.2 www.hv.pl [email protected] 1 2 3 5 Pump weight free shaft end with coupling 58 58 58 58 58 58 58 62 62 62 62 62 62 62 62 59,5 61 61 61 62 67 67 65 65 65 66 71 71 73,3 73,3 with coupling and plate with coupling, plate and motor 82 82 82 87 88 104 104 86 86 91 92 108 108 118,3 120,3 108 116,5 122 144 149 197 212 117,5 126 145 153 201 216 235,3 261,3 kg Motor Foundation plate Assembly outline dimension Coupling type E3 E7 E7 E9 E9 E10 E10 E7 E7 E9 E9 E10 E10 E10 140A Mechanical size Power 90L2 100L2 112M2 132S2A 132S2B 160M2A 160M2B 100L2 112M2 132S2A 132S2B 160M2A 160M2B 160L2 180M2 2,2 3,0 4,0 5,5 7,5 11,0 15,0 3,0 4,0 5,5 7,5 11,0 15,0 18,5 22,0 KW plate block P H 278 278 278 278 278 278 278 306 306 306 306 306 306 306 306 400 400 400 400 400 400 400 420 420 420 420 420 420 450 470 number 60.36.01.1 60.37.01.1 60.37.02.1 60.38.01.1 60.38.01.1 60.40.03.1 60.40.03.1 60.37.01.1 60.37.02.1 60.38.01.1 60.38.01.1 60.40.03.1 60.40.03.1 60.40.03.1 60.40.01.1 M L 220 280 280 310 310 345 345 280 280 310 310 345 345 420 420 1005 1005 1045 1084 1124 1096 1116 1040 1070 1109 1144 1116 1189 1264 1312 mm - ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska tel. +48(56) 45 07 410; fax: +48(56) 46 25 955 5 PUMP DIMENSIONS Dimension of KSM pumps The pumping units with motor power up to 3 kW SKg90L-4/FF165 SKg80-4A/FT165 SKg90L-2/FF165 SKg100L-2/FT165 SLg112M-2/FT165 SKg132S-2A/FT165 SLg1132-2B/FT165 SLg160M-2A/FF300 SLg160M-2B/FF300 SKg80-4A/FF165 SKg80-4B/FF165 SKg90S-4/FF165 SKg90L-4/FF165 SKg100l-4A/FT165 SKg100L-2/FT165 SLg112m-2/FT165 SKg132S-2A/FT165 SLg132S-2B/FT165 SLg160M-2A/FF300 SLG160M-2B/FF300 KSM7.2 SKg90S-4/FF165 KSM7.1 SKg80-4B/FF165 Power (kW) rpm min-1 DN1** DN 2** a** b1** b 2** b 3** d1** d2** d3** d4** d5** d 6** d7** d8** N1** N 2** h1** h 2** h 3** h 4** i** l1** l2** m1** m2** n 3** n 4** s** w** Weight (kg) KSM5.1 SKg80-4A/FF165 Motor type KSM5.1 The pumping units with motor power over 4 kW 0,55 1450 65 50 100 140 142 200 157 145 125 185 165 18 8 4 160 180 135 106 533 362 200 51,0 0,75 1450 65 50 100 140 142 200 157 145 125 185 165 18 8 4 160 180 135 106 533 362 200 52,0 1,10 1450 65 50 100 140 142 200 175 145 125 185 165 18 8 4 160 180 135 106 556 385 200 58,0 1,50 1450 65 50 100 140 142 200 175 145 125 185 165 18 8 4 160 180 135 106 581 410 200 61,5 2,20 1450 65 50 100 140 142 200 205 145 125 185 165 18 8 4 160 180 135 106 614 443 200 70,5 2,20 2900 65 50 100 140 142 200 175 145 125 185 165 18 8 4 160 180 135 106 581 410 200 62,5 3,00 2900 65 50 100 140 142 200 205 145 125 185 165 18 8 4 160 180 135 106 614 443 200 72,0 4,00 2900 65 50 100 54 140 142 12 200 231 145 125 185 165 18 8 4 180 135 112 270 624 172 140 246 190 15 200 75,0 5,50 2900 65 50 100 71 140 142 12 200 263 145 125 185 165 18 8 4 180 135 132 289 683 180 140 274 216 18 200 98,5 7,50 2900 65 50 100 71 140 142 12 20 263 145 125 185 165 18 8 4 180 135 132 289 721 180 140 274 216 18 200 106,5 11,00 2900 65 50 100 60 140 142 15 350 323 145 125 185 165 18 8 4 180 135 160 338 832 250 210 300 254 20 230 148,5 15,00 2900 65 50 100 60 140 142 15 350 323 145 125 185 165 18 8 4 180 135 160 338 832 250 210 300 254 20 230 164,5 0,55 1450 80 65 125 140 152 200 157 160 145 200 185 18 8 8 160 200 145 109 543 344 203 64,5 0,75 1450 80 65 125 140 152 200 157 160 145 200 185 18 8 8 160 200 145 109 560 361 203 65,5 1,10 1450 80 65 125 140 152 200 175 160 145 200 185 18 8 8 160 200 145 109 583 384 203 71,0 1,50 1450 80 65 125 140 152 200 175 160 145 200 185 18 8 8 160 200 145 109 608 409 203 72,5 2,20 1450 80 65 125 140 152 200 205 160 145 200 185 18 8 8 160 200 145 109 644 445 203 80,5 3,00 2900 80 65 125 140 152 200 205 160 145 200 185 18 8 8 160 200 145 109 644 445 203 82,0 4,00 2900 80 65 125 54 140 152 12 200 231 160 145 200 185 18 8 8 200 145 112 273 652 172 140 246 190 15 203 90,0 5,50 2900 80 65 125 71 140 152 12 200 263 160 145 200 185 18 8 8 200 145 132 292 688 180 140 274 216 18 203 113,0 7,50 2900 80 65 125 71 140 152 13 200 263 160 145 200 185 18 8 8 200 145 132 292 728 180 140 274 216 18 203 121,0 11,00 2900 80 65 125 60 140 152 15 350 323 160 145 200 185 18 8 8 200 145 160 341 868 250 210 300 254 20 233 156,0 15,00 2900 80 65 125 60 140 152 15 350 323 160 145 200 185 18 8 8 200 145 160 341 868 250 210 300 254 20 233 171,0 *) - the above dimensions have been taken from the catalogue of „Tamel” (the manufacturer of motors). Data for motors of other manufacturers may differ. **) - number of holes in the connection flanges (suction discharge) ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska tel. +48(56) 45 07 410; fax: +48(56) 46 25 955 6 www.hv.pl [email protected] GEN ER AL I N FOR M AT ION Product symbol structure The pump symbol consists the following elements: where: a a a b c c d e e1 e1 e2 h h 1 2 3 4 5 - produkt name (KS or KSM) - pump size - pump dimension (concerning the diameter of the impeller) - material selection - pump design - delivery completeness, according to internal documents of the manufacturer Variant name The pump with free haf end The pump with complete coupling The pump with complete coupling, foundation bolts and coupling cover on he foundation plate Uni-block Completeness 3 + motor KS X X KSM X X X Motor protection To ensure smooth failure-free motor operation, it is necessary to install devices securing from: w w w w poverload, phase decay and feeding asymmetry, symmetric decline of supply voltage, excessive number of switches, dry run. These functions are fulfilled by protection-control device of UZS type produced by Hydro-Vacuum S.A. Single-phase motor pumping units are serially equipped with a staring switch with built-in: w unipolar switch, w WEBER thermistor, w start-work capacitor. To ensure long life of the motor, it is recommended not to switch it more han 20 times an hour. The switching on cycle should be not shorter than every 3 minutes. Attestations and certificates Attest no W/683/95 obtained from State Institute of Hygiene. „Power Engineering Attest” obtained from the Ministry of Industry and Trade. „B” safety mark, obtained from PCBC. www.hv.pl [email protected] ul. Droga Jeziorna 8, 86-303 Grudziądz, Polska tel. +48(56) 45 07 410; fax: +48(56) 46 25 955 7 Hydro-Vacuum S.A. w thousands of satisfied clients in Poland and abroad w almost 150 years of experience w designed, manufactured and sold millions of pumps ul. Droga Jeziorna 8, 86-303 Grudziądz, Poland tel. +48(56) 45 07 410, fax +48(56) 45 25 955 Export Department: tel. +48(56) 45 07 554 ; fax. +48(56) 45 07 346 www.hv.pl • [email protected] Guaranteed satisfaction with the use of our products!