CalDAG REFERENCE SHEET
Transcription
CalDAG REFERENCE SHEET
11B – 215. Fire alarm systems 11 B – 215.2: alarms in public use areas in common use areas shall comply with Chapter 9, Section 90 7.5.2.3.1. Exception: In existing facilities, visible alarms shall not be required except where the existing fire alarm system is upgraded or replaced, or a new fire alarm system is installed. 11 B – 216. Signs 11 B – 216.1: Signs shall comply with Section 11 B – 703. See Exception: to 11 B – 216. 11 B – 217. Telephones 11 B – 217.1: Where pay telephones are provided, accessible telephones shall be provided in accordance with Section 11 B – 270. 11 B – 219. Assistive listening systems 11 B – 219.2: An assistive listening systems shall be provided in assembly areas, including conference and meeting rooms. 8/12/2015 9:33:30 AM N. 0 T E 10 - 3 1 - 2 R O F CA L I FO PROJECT NO: Project Number PROJECT ISSUE DATE: Issue Date 081-131-20 A.P.N.: 13230 CENTRAL AVENUE BOULDER CREEK, CA 95006 DESIGNED BY: Designer C-33938 D A R CH CE IT N E BARKE D I 12" = 1'-0" SCALE: CalDAG REFERENCE SHEET 13230 CENTRAL AVENUE BOULDER CREEK, CA 95006 OFFICE: 831 338-7222 SEISMIC UPGRADE & ACCESSIBILITY IMPROVEMENT CONTACT: KEVIN McCLISH PROJECT: FIGURE 11B-505.10.3 A-4 11 B – 214. Washing machines and clothes dryers: Where three or fewer washing machines and/or clothes dryers are provided, at least one shall comply with Section 11 B – 611. Where more than three are provided, at least two shall comply with section 11 B – 611. FIGURE 11B-404.2.4.1 Description 11B-213. Toilet rooms and bathing rooms. 11B-213.2: Where toilet rooms and bathing rooms are provided, each toilet room shall comply with section 11 B – 603. Exception to 11 B – 213.2: 1. In alterations where it is technically infeasible to comply, altering existing toilet or bathing rooms shall not be required where a single unisex toilet room or bathing room is provided and located in the same area and on the same floor as existing in accessible toilet or bathing rooms. 4. Where multiple single user toilet rooms are clustered in a single location, 50%, but no fewer than one of the single-user toilet rooms at each cluster shall be compliant. 11B-213.2.1: Unisex toilet and unisex baiting room. Unisex toilet rooms shall contain not more than one laboratory, and not more than two water closets without urinals or one water closet and one urinal. 11 B – 213.3: Plumbing fixtures and accessories. 11B-213.3.1: Toilet compartments. --Where less than 6 toilet compartments are provided, at least one toilet compartment shall comply with Section 11 B – 604.8 .1. -- Where six or more toilet compartments are provided, or where the combination of urinals and water closets total six or more, at least one compartment shall comply with Section 11 B – 604.8 .2. 11B-213.3.2: Water closets. Where water closets are provided at least one shall comply with section 11 B – 604. 11B-213.3.3: Urinals. Where one or more urinals are provided at least once shall comply with Section 11 B – 605. 11B-213.3.4: Lavatories. Where lavatories are provided at least 5% but no fewer than one shall comply with Section 11 B – 606. 11B-213.3.5: Mirrors. Where mirrors are provided at least one shall comply with Section 11 B – 603.3. 11B-213.3.6: Bathing facilities. 11B-213.3.7: Coathooks and shelves in toilet rooms. Date 11B-209. Passenger loading zones and bus stops 11B-209.2.1: Passenger loading zones. At least one compliant loading zone shall be provided in every continuous 100 linear feet of loading zone space, or fraction thereof. RE A ST Rev. 11B-208. Parking spaces 11B-208.2: Minimum number. Parking spaces shall be provided in accordance with table 11 B – 208.2. 11B-208.2.4: Van parking spaces. For every six or fraction of six parking spaces, at least one shall be a Van parking space. 11B-208.3.1: Location. Accessible parking spaces shall be on the shortest accessible route from parking to a compliant entrance. Where parking serves more than one accessible entrance, spaces shall be disbursed and located on the shortest accessible route to the accessible entrances. OWNER: 11 B – 207. Accessible means of egress. 11B-207.1: Means of egress shall comply with Chapter 10, Section 1007. SHEET TITLE: . Accessible Routes 11B-206.2.1: Site arrival points. At least one accessible route shall be provided from accessible parking spaces and accessible passenger loading zones: public streets and sidewalks; and public transportation stops to the accessible building entrance. 11B-206.2.2: At least one accessible route shall connect accessible buildings, accessible elements and accessible spaces that are on the same site. 11B-206.2.3: Multi-story buildings and facilities. At least one accessible route shall connect each story and mezzanine in multistory buildings. See Exceptions to 11B-206.2.3 (Accessible Routes): 11B-206.3: Location. Accessible Routes shall coincide with or be located in the same area as general circulation paths. An accessible route shall not pass through kitchens, storage rooms, restrooms, closets or other spaces for similar purposes. 11B-206.4: Entrances: Entrances shall be on an accessible route. 11B-206.1: All entrances and exterior ground-floor exits to buildings shall comply with section 11 B – 404. Exceptions to 11B-206.1: 1. Exterior ground-floor exits serving smoke proof enclosures, stairwells, and exit doors serving stairs only shall not be required to comply. 2. Exits in excess of those required by chapter 10, and which are more than 24 inches above grade shall not be required to comply. Such doors shall have warning signs complying with section 11 B – 703.5, stating that they are not accessible. I wasn't I was working Revision Schedule 11B-206 11 B – 502 Parking spaces (See Figures 11B – 502.2 through 11B – 502.3 .3) Car parking spaces: Shall be 216" long by 108" wide min. 11B-302 Floor surfaces Van parking spaces: Shall be 216" wide by 144" wide. 11B-302.2: Carpet shall be securely attached. Carpet shall have the level Exception: Van parking spaces may be 108" wide minimum where the loop, textured loop, level cut pile, level cut/uncut pile texture. File height shall be one access file is 96"wide minimum. half inch maximum. Exposed edges shall be fastened to floor surfaces and shall have 11 B – 502.3: Access aisles shall adjoin an accessible route. Two parking trim on the entire length of the exposed edge. Carpet edge trim shall comply with spaces shall be permitted to share a common access aisle. Section 11 B – 303. 11 B – 502.3 .1: Width: Access files shall be 60" wide minimum 11 B – 302.3: Openings in floor or ground surfaces shall not allow passage 11 B – 502.3 .2: Length: Access aisles shall extend the full required of a sphere more than one half inch diameter except as allowed in Sections 11 B – length of the parking spaces they serve. 407.4 .3. (Platform to waste away your). 11 B – 502.3 .3: Markings: Access aisles shall be marked with a blue painted borderline around the perimeter. The area within the blue borderline shall be 11 B – 303 Changes in level marked with hatched lines a maximum of 36" on center in a color that contrasts with 11 B – 303.2: Vertical changes in level of 1/4 inch high maximum shall be that of the aisle surface preferably blue or white. The words " NO PARKING" shall permitted to be vertical and without edge treatment. be painted on the surface in each access aisle white letters a minimum of 12" high 11 B – 303.3: Changes in level between 1/4 inch high minimum and 1/2 inch and located be visible from the adjacent vehicular way. high maximum shall be beveled with the slope not steeper than 1:2. 11 B – 502.3 .4: Location: Access aisle shall not overlap the vehicular 11 B – 303.4: Changes in level greater than 1/2 inch high shall be ramped way. and shall comply with Section 11 B – 405 or more 11 B – 406. Van parking space aisles shall be located on the passenger side of the parking 11 B – 303.5: Abrupt changes in level exceeding 4 inches in a vertical space. dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces shall be identified by warning curbs at least 6 inches in height above the walk or 11 B – 504 Stairways sidewalk surface. Exception: 11 B – 504.2: Treads and risers. All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4" high minimum, 1) A warning curb is not required between a walk or sidewalk and the and 7" high maximum. Treads shall be 11" deep minimum. Open risers are not adjacent street or driveway. permitted. Exceptions: 11 B – 304 Turning space 1. On exterior stairways an opening of not more than 1/2" may be 11 B – 304.2: Turning spaces shall not be sloped greater than 1:48. permitted between the base of the riser and the tread. 11 B – 304.3 .1: Circular turning space shall be 60 inches diameter 2. On exterior stairways, risers constructed of grating containing openings minimum. The space shall be permitted to include knee and toe clearance complying and not more than 1/2" may be permitted. with Section 11 B – 306. 11 B – 504.4: Tread surface shall not have a slope steeper than 1:48. 11 B – 304.3 .2: T–Shaped turning space shall fit within a minimum 60 inch 11 B – 504.4 .1: Contrasting stripe. The upper approach to stairs and square with minumum 36 inch wide arms and leg. Arms shall extend the minimum of lower trade shall be marked by a stripe providing clear visual contrast. Exterior stairs 12 inches beyond the leg on each side, and the leg shall extend a minimum of 24 shall have all treads marked by a stripe providing clear visual contrast. inches below the arms. Ends of the arms and leg shall be permitted to include me and 11 B – 504.5: Nosings. The radius of curvature at the leading edge of the told clearance complying with Section 11 B – 306. tread shall be one half inch maximum. Nosings that project be on the risers shall 11 B – 304.4: Doors shall be permitted to swing into turning spaces. have the underside of the leading edge curve or beveled. Risers are permitted the slope under the tread at an angle of 30° maximum from vertical. The permitted 11 B – 306.2 Toe clearance projection of the nosing shall extend 1 1/4" maximum over the tread below. 11 B – 306.2 .1: Toe space shall extend a minimum of 9 inches above the 11 B – 504.8: Floor identification. In an enclosed stairway, each level shall finish floor. be identified with a sign adjacent to the door entering the enclosed stairway. Signs 11 B – 306.2 .2: Toe clearance shall extend 25 inches maximum under an shall be located adjacent to the latch side of the door. At the exit discharge level, element. the signs shall include a raised five pointed star located to the left of the identifying 11 B – 306.2.3: Toe clearance required as a part of clear floors pace shall lower-level. The outside diameter the start shall be the same as the height of the extend 17 inches minimum under the element. characters. See Exceptions to Section 11 B – 306.2 .3, and Figure 11B-306.3 11 – 306.2 .5: Told clearance shall be 30 inches wide minimum. 11 B – 505 Handrails 11 B – 505.2: Handrails shall be provided on both sides the stairs and 11 B – 306.3 Knee clearance: See CalDAG Figure 306.3 ramps. Exceptions: 11 B – 306.3 .5: Knee clearance shall be 30 inches wide minimum. 1. In assembly areas, handrails are not required on both sides of aisle ramps where a handrail is provided at either side or within the aisle. 11 B – 307 Protruding objects: See CalDAG Figures 11B-307.2, .3, and .4 2. Curb ramps to require handrails. 3. At door landings, handrails are not required when the ramp is less than 11 B – 308 Reach ranges: See CalDAG Figure 308.2.2. 6" in rise or 72" in length. 11 B – 505.3: Continuity. Handrails be continuous within the full length of 11 B – 402 Accessible routes each pair flight or ramp run. Inside handrails on switch back or dogleg stairs and 11 B – 402.2: Accessible routes shall consist of one or more of the following ramps shall be continuous between flights or runs. Exception: components: walking surfaces with a running slope not steeper than 1:20, CalDAG In assembly areas, handrails are not required adjacent to seating or within compliant doorways, ramps, curb ramps (excluding the flared sides), elevators and the aisle width. platform lifts. 11 B – 505.4: Height. Top of gripping surfaces of handrails shall be between 34" minimum and 38" maximum above walking surfaces, stair nosings, and 11 B – 403 Walking surfaces ramp surfaces. Handrails shall be at a consistent height above walking surfaces, 11 B – 403.3: The running slope of walking surfaces shall not be steeper stair nosings, and ramp surfaces. than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48. 11 B – 505.5: Clearance between handrail gripping surfaces and adjacent Exception: the running slope of sidewalks shall not exceed the general grade surface shall be 1 1/2" minimum. Handrails may be located in a recess if the recesses is 3" deep and 18" minimum above the top of the handrail. established for the adjacent street or highway. 11 B – 403.5.1: Except as noted in section 11 B – 403.5 .2 and 5.3 (width at 11 B – 505.6: Handrail gripping surface shall be continuous along its length turns, and width of passing spaces), clear width of walking surfaces shall be 36 inches and shall not be obstructed along the top or sides. Where provided horizontal minimum. (See CalDAG Figure 403.5.1) projections shall occur 1 1/2" minimum below the bottom of the handrail gripping surface. Exceptions: 11 B – 505.7 .1: Circular cross section. Handrail gripping surface with a 1. The clear with may be reduced to 36 "minimum for any length of 24" circular cross-section shall have an outside dimension of 1 1/4" minimum and 2" maximum provided that reduced with segments are separated by at least 48 inches. 2. With four walking surfaces and core doors serving an occupant load of 10 maximum. 11 B – 505.7 .2: Noncircular cross sections shall have a perimeter or more shall be 44 inches minimum. dimension of between 4" minimum and 6 1/4" maximum and a cross-sectional 3. The clear with four sidewalks and walks shall be 48 inches minimum. If right-of-way restrictions, natural barriers, or other existing conditions, and the enforcing dimension of 2 1/4" maximum 11 B – 505.10: Handrail extensions. Exceptions: agency determines that compliance with the 48 inch clear sidewalk with would create an unreasonable hardship, the clear with may be reduced to 36 inches. 1. Extensions are not required for continuous to handrails at the inside turn 4. The clear with for aisles shall be 36 inches minimum if serving elements of switch back or dogleg stairs and ramps. on only one side, and 44 inches minimum if serving elements on both sides. 3. In alterations, where the extension of handrails would create a hazard, 11 B – 403.5 .3: An accessible route with a clear space less than 60" shall the extension may be turned 90° from the ramp run. provide passing spaces at intervals of 200 feet maximum. Passing spaces shall be 11 B – 505.10 .1: Ramp handrails shall extend horizontally for 12" beyond either a space 60 inches minimum by 60" minimum or an intersection of two walking the top and bottom of ramp runs. Extensions shall return to the wall, guard, or the surfaces providing a T-shaped space complying with section 11 B – 304.3 .2. landing surface, or shall be continuous to the handrail of of an adjacent ramp run. 11 B – 403.7: All walks with continuous gradient shall have resting areas 60" See Figure 11 B – 505.10.1 in length at intervals of 400 feet maximum resting areas shall be at least as wide as the 11 B – 505.10 .2: Stair handrails shall extend horizontally for 12" beyond lock the slope of the resting area in all directions shall be 1:48 maximum. the top step tread nosing. 11 B – 505.10 .3: Stair handrails shall extend horizontally for (12" plus the 11 B – 404 Doors, doorways, and Gates depth of one stair tread) beyond the bottom step tread nosing. Exception: Doors, doorways, and Gates designed to be operated only by 11 B – 602 Drinking fountains (See Section) security personnel shall not be required to comply. A sign visible from the approach 11B-211.2: No fewer than 2 drinking fountains shall be provided. site complying with section 11 B – 703.5 shall be posted stating '"Entry restricted and --One shall comply with 11B-602.1 thru 11B-602.6 for wheelcair accessibility: controlled by security personnel". 11B-602.2 -->11B-305.3: Provided 30"x48" clear space, centered. 11 B – 404.2 .1: Revolving doors, gates, and turnstiles shall not be part of an --Alcoves for perpendicular approach to be 36" wide if deeper than 24". accessible route. --Alcoves for parallel approach to be 60" if deeper than 15". 11 B – 404.2 .2: Double leaf doors and gates. At least one of the activities --> 11B-305.4: Provide Knee & Toe Space per Figure 11B-306.3(a) of doorways with two leaves shall comply with Sections 11 B – 404.2 .3 and 11 B – --Spout to be 36" max above fin. floor, & 5" max. from front edge. 404.2 .4 --One shall comply with Section 11B-602.7 for standing access: Spout to be 11 B – 404.2 .3: Door openings shall provide a clear width of 32 inches minimum. Clear openings of doorways this doors shall be measured between the face between 38" & 43" above the finish floor. 11B-602.8: Depth: Between 18" min. & 19" max. of the door and the stop, with the door open 90°. Openings more than 24 inches deep 11B-602.9: Fixture to be located completely within alcove 32" wide x 18" shall provide a clear opening of 36 inches minimum. There shall be no projections into the required openings lower than 34 inches above the finish floor. Projections into the deep. Or similar wing walls as deep as the fixture & to within 6" of the flloor. clear opening with above 34 inches and less than 80 inches above the finish floor or 11 B – 603 Toilet and bathing rooms ground shall not exceed 4 inches. 11 B – 603.2 .1: Turning space complying with Section 11 B – 304 shall Exceptions: be provided within the room. 1. In alterations, a projection of 5/8 inch maximum into the required clear width shall be permitted for the latch side stop. 11 B – 603.2 .2: Overlap. Required clear floor spaces, clearances it 2. Door closers in doorstops shall be permitted to be 78 inches minimum fixtures, and turning space shall be permitted to overlap. above the finish floor or ground. 11 B – 404.2 .4: Maneuvering clearances. See CalDAG Figures 11 B – 11 B – 603.2 .3: Door swing shall not overlap the clear floor space or clearance required for any fixture. Other than the door to accessible water closet 404.2.3 through Figure 11 B – 404.2.6 11 B – 404.2 .9: Door and gate opening force. The force for pushing or compartment, a door in any position, may encroach into the turnings base by 12" maximum. (See Exceptions to 11 B – 603.2 .3) pulling open a door or gate other than fire doors shall be 5 pounds maximum. The 11 B – 603.3: Mirrors located above lavatories are countertops shall be force required to open fire doors shall not exceed 15 pounds. installed with the bottom edge of the reflecting surface 40 inches maximum above Exceptions: the finish floor. Mirrors not located above lavatories are countertops shall be installed 1. Exterior doors to machinery spaces. with the bottom edge of the reflecting surface 35 inches maximum above the finish 2. When it a single location, if one of every eight exterior door leaves is a floor. powered door, other exterior doors at the same location serving the same interior 11 B – 603.4: Coathooks, shelves and medicine cabinets. space may have a maximum opening force of 8.5 pounds. The powered leaf shall be 11 B – 603.5: Accessories. Where dispensers, waste receptacles, other located closest to the accessible route. 11 B – 404.2 .10: Swinging door and gate surfaces within 10 inches of the accessories are provided in toilet facilities at least one of each type shall be located finish floor vertically shall have a smooth surface on push side extending the full width on an accessible route. All operable parts shall be 40 inches maximum above the of the door. Parts creating horizontal or vertical joints in those services shall be within finish floor. 1/16 inch of the same plane and be free of sharp or abrasive edges. 11 B – 604 Water closets and toilet compartments. (See Figures 11 B – 11 B – 405 Ramps 604.2 through Figure 11 B – 605.2. 11 B – 604.2: The centerline of the water closets shall be between 17" min. 11 B – 405.2: Slope. Ramps shall have a slope not steeper than 1:12. and 18" max. From the sidewall or partition. 11 B – 405.3: Cross slope shall not be steeper than 1:48. 11 B – 604.3 .1: Clearance around the water closets shall be 60 inches 11 B – 405.5: The clear width of a ramp shall be 48 inches minimum. Handrails may project into the required width 3 1/2 inches on each side at the handrail minimum measured perpendicular to the sidewall and 56" minimum measured perpendicular to the rear wall. A minimum 60" wide and 48" deep maneuvering space height. Exception: The clear width of ramps in residential uses serving an occupant shall be provided in front of the water closet. 11B-604.8.1.2: Doors to toilet compartments shall provide a clear width of load of 50 or less shall be 36 inches minimum between handrails. 11 B – 405.6: The rise for any ramp run shall be 30 inches maximum. 32 inches minimum. SHEET NUMBER: 11B-203. General Exceptions 11B-203.2: Construction sites. Structures directly associated with the process of construction shall not be required to comply (eg: scaffolding, bridging, materials hoist, materials storage and construction trailers). 11B-203.4: Limited access spaces. Spaces not customarily occupied and accessed only by letters, catwalks, crawlspaces, or very narrow passageways shall not be required to comply. 11B-203.5: Machinery spaces. Spaces frequented only by service personnel for maintenance, repair or occasional monitoring of equipment shall not be required to comply. 11 B – 247 Detectable warnings 11B-247.1.2.1: Platform edges. Shall comply with Section 11B-705.1.1 and 11B-705.1.2.2 11B-247.1.2.2: Curb ramps. Shall comply with Section 11B-705.1.1 and 11B-705.1.2.2 11B-247.1.2.3: Islands or cut-through median's. Shall comply with Section 11B-705.1.1 and 11B-705.1.2.3 LI C DA V 11 B- 202: Existing buildings: 11 B- 202.3 .1: Reduction in access is prohibited. 11 B – 202.4: Provide an accessible path of travel to the specific area of alteration or addition. The primary accessible path of travel shall include: 1. A primary entrance to the building or facility. 2. Toilet and beating facilities serving the area. 3. Drinking fountains serving the area. 4. Public telephones serving the area. Note Section 11 B – 217, ... Not required if public telephones are not provided. 5. Signs. Exceptions to 11B-202.4 (Accessible Path): 1. Residential dwelling units shall comply with Section 11 B-233.4.2. 2. Path of travel elements constructed in compliance with the immediate preceding edition of CBC shall not be required to be retrofitted to reflect the incremental changes in the code solely because of an alteration to an area served by those elements. 3(a). Altering one building entrance. 3(b). Altering one existing toilet facility. 3(c). Altering existing elevators. 3(d). Altering the existing steps. 3(e). Altering existing handrails. 4. Alterations solely for the purpose of barrier removal pursuant to the requirements of ADA or CalDAG shall be limited to the scope of work. (See 11B-204.4 for itemized list) 5. Resurfacing or restriping of (E) parking lot. 6. The addition or replacement of signs and/or identification devices. 7. Projects consisting only of HVAC, reroofing, electrical work not involving placement of switches and receptacles, cosmetic work (eg. painting etc.) 8. (See 11B-202.4 Hardship Exception) 11 B – 229. Windows 11 B – 229.1: Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with Section 11 B – 309. 15 11B-201.4: These requirements shall apply to temporary or permanent construction support facilities for uses in activities not directly associated with actual process of construction… When provided, toilet and bathing facilities serving construction support facilities shall comply with section 11 B – 213. Exception: During construction and accessible route shall not be required between site arrival points or the boundary of the area construction in the entrance to the construction support facilities if the only means of access between them is a vehicular way not providing pedestrian access. 11 B – 405.7: Except where the ramp changes direction or the top and bottom of the ramp the landing width shall be at least as wide as the widest ramp run leading to the landing 11 B – 405.7.2.1: The Top landing shall be 60" wide by 60" long min. 11 B – 40 5.7.3.1: Bottom landings shall extend 72" minimum in the direction of the ramp run 11 B – 405.7.4: Changes in direction. Landings between ramp runs that change direction shall have a clear landing width of 60" minimum, and shall extend 72" minimum in the direction of downward travel from the upper ramp run. 11 B – 405.7 .5: Where doorways are located adjacent to a ramp, doorway maneuvering clearances may overlap the required landing area, however: 1. Doors, when fully open, shall not reduce the required ramp and equipped by more than 3". 2. Doors, and any position, shall not reduce the minimum dimension of the ramp landing to less than 42". 11 B – 405.9 .2: A curb 2" high minimum, or a barrier that prevents the passage of a 4" diameter sphere shall be provided, uninterrupted, along the length of the ramp. IA 11B-103: Nothing in these requirements prevents the use of designs, products, or technologies has alternatives to those prescribed, provide a result in substantially equivalent or greater accessibility and usability. 11 B – 219.3: The minimum number of receivers shall be equal to 4% of the total number of seats, but in no case less than two. 25% minimum of receivers provided, but no fewer than two, and shall be hearing aid compatible. 11 B – 221. Assembly area seating 11 B – 221.1: Assembly areas shall provide wheelchair spaces, companion seats, designated aisle seats, and semi-ambulant seats complying with Section 11 B – 221 and 11 B – 802 N CBC CHAPTER 11B - ACCESSIBILITY TO PUBLIC BUILDINGS T EC W LE DETAIL 15-A6, ACCESSIBLE ROUTE SIGN (E) AWNING H E PAT G A N I DRA UP BOLLARD STOR. STOR. 2' - 2" 5' - 0" 3 COVERED PATIO (E) ROLL-UP DOOR A-5 TRAINING ROOM #2 SIGNAGE - ACCESSIBLE PARKING SPACE 3" = 1'-0" GARAGE FIRE GEAR DN KITCHEN OFFICE PANTRY OFFICE SHEET TITLE: OFFICE (E) BOLLARD RAMP OFFICE DETECTABLE WARNING 4' - 0" 3' - 0" PATH OF TRAVEL FROM BUS STOP AND SIDEWALK 1 SITE ACCESSIBILITY PLAN 1" = 10'-0" STATE HIGHWAY 9 SHEET NUMBER: (E) CONC. DRIVEWAY A-5 Rev. DN DETAIL 15-A6, ACCESSIBLE ROUTE SIGN EXISTING BUS STOP Date 7 A-6 Revision Schedule DN Description TRAINING ROOM #1 DN 8/12/2015 9:33:40 AM N. 0 T E 10 - 3 1 - 2 R O F CA L I FO (E) As indicated APPARATUS BAY EXISTING WALKWAY 4' - 2" SCALE: NOTE: AN ADDITIONAL SIGN SHALL BE POSTED IN A CONSPICUOUS PLACE AT THE ENTRANCE TO THE OFFSTREET PARKINFG FACILITY, OR ADJACENT TO AND VISIBLE FROM EACH ACCESSIBLE PARKING SPACE. --THE SIGN SHALL BE 17"X 22" MINIMUM SIZE, --WITH 1" MINIMUM LETTERING THAT STATES THE FOLLOWING: "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or special license plates issued for persons with disabilities will be towed away at the owner's expense. Towed vehicles may be reclaimed at_______or by telephoning________." OWNER: LAUNDRY WALL-MOUNTED SIGNAGE AS REQUIRED FOR VAN-ACCESSIBLE PARKING SPACE, SEE DETAIL (E) 80" MINIMUM TO TOP OF WALKING SURFACE. 3 BATH (E) SOLAR POWER CONTROL PANEL SITE ACCESSIBILITY PLAN ADDITIONAL SIGNAGE REQ'D. @ VAN ACCESSIBLE PARKING SPACE 13230 CENTRAL AVENUE BOULDER CREEK, CA 95006 OFFICE: 831 338-7222 ADDITIONAL SIGNAGE REQ'D. @ ACCESSIBLE PARKING SPACE CONTACT: KEVIN McCLISH EMERGENCY VEHICLE STAGING ZONE (N) VAN ACCESSIBLE PARKING SPACE 1/2" RADIUS, TYP. PROJECT NO: Project Number CROSSWALK MARKING: WHITE, 1' x 8' @ 2' O.C. PROJECT: ACCESSIBLE PATH OF TRAVEL TO ALTERED AREAS (E) ACCESSIBLE PARKING SPACE INTERNATIONAL SYMBOL OF ACCESSIBILITY AND ALL LETTERING TO BE WHITE ON BLUE BACKGROUND 3' - 0" PROJECT ISSUE DATE: Issue Date SIGN TO BE CENTERED AT INTERIOR END OF PARKING SPACE. 081-131-20 70 SQUARE INCHES MINIMUM. A.P.N.: (N) DETECTABLE WARNING CBC 11B-705.1.1.3 CBC 11B-705.1.2.5 DESIGNED BY: Designer UTILITY/ STORAGE RE A ST 13230 CENTRAL AVENUE BOULDER CREEK, CA 95006 4' - 0" 3' - 0" REFLECTORIZED SIGN CONSTRUCTED OF PORCELAIN STEEL WITH BEADED TEXT. C-33938 D A R CH CE IT N E BARKE D I OVERVIEW 10' - 0" 4' - 5" 2 SEISMIC UPGRADE & ACCESSIBILITY IMPROVEMENT LI C DA V 47' - 11" 15 CBC 11B-705.1.2.5 Keynote Contrast: Detectable warnings shall contrast with adjacent walking surfaces either light-on-dark or dark-on-light. Detectable warnings in hazardous vehicular areas shall be 36" wide. IA Key CBC 11B-705.1.1.3 T EC W LE N SHEET KEY NOTES 0' - 1 1/16" / 1' - 0" 4' - 9" 1' - 1 1/4" A-6 F.F. -4.0 in 3' - 8" DN 4' - 0" F.F. -3.9 in F.F. -4.0 in CBC 11B-505.7 72" X 48" LANDING AREA AT BOTTOM OF RAMP See CBC 11B-405.7.3 & 11B-405.7.3.1 PERVIOUS CONC. CBC 11B-405.9.2 CBC 11B-505.2 CBC 11B-505.3 CBC 11B-505.4 CBC 11B-505.7 CBC 11B-505.9 CBC 11B-505.10.1 4 A-6 2 NEW CONCRETE WALKWAY @ (E) STUCCO-FINISH WALL 1 1/2" = 1'-0" CBC 11B-505.9 CBC 11B-505.10 (E) BOLLARD F.F. -32.1 in 5 A-6 CBC 11B-505.10.1 CBC 11B-505.10.2 -30.50 RAMP SLOPE: 1 Inch / Foot (DOWN) per CBC 11B-405.2 (CROSS SLOPE NOT MORE THAN 1:48) -31.50 2' - 0" 6 0' - 0 1/4" / 1' - 0" 5' - 4" F.F. -2.8 in BETWEEN RAILINGS F.F. -2.6 in NOTE: SPOT ELEVATIONS ARE APPROXIMATE AND REFERENCED TO THE INTERIOR FIN. FLOOR. ACTUAL SPOT-ELEVATION VALUES AND RUN-LENGTHS ARE GOVERNED BY THE ANNOTTED SLOPE VALUES, ANNOTATED MANUEVERING CLEARANCES, AND ACTUAL SITE CONDITIONS. DN CBC 11B-505.10.3 30' - 0" +/- CBC 11B-505.2 CBC 11B-405.5 60"x60" UPPER LANDING (RAMP) per 11B-405.7.2.1 & 11B-405.7.3 3' - 0" REPLACE (E) LANDSCAPE WALL SEGMENT TO PROVIDE 44" WIDE PATHWAY TO RAMP. PROVIDE NEW PERVIOUS CONC. WALKWAY w/ SLOPE NOT GREATER THAN 1:20 4' - 0" 3' - 0" 4' - 0" 48"X48" LANDING @ TOP, BOTTOM, & MID-LANDING PER CBC 1009 3' - 0" 4' - 0" 2' - 8" 4' - 0" 3' - 0" 4' - 0" 4' - 0" CBC 1009.7.4 8 CBC 1009.8 4' - 6" (E) CONCRETE SIDEWALK A-6 (N) PERVIOUS CONCRETE WALKWAY Compacted Crushed Gravel Sub-Base, ASTM D448 #57 (N) DETACTABLE WARNING ACCESSIBLE RAMP & STAIR PLAN 7 1/4" = 1'-0" Concrete Slab w/ #4 R.B. @ 12" o.c. each way 4" Bedding, ASTM D448 #8 0' - 2" CBC 1009.7.5 1/2" X 5 1/2" CORK EXPANSION JOINT MATERIAL. JOINT SEALER FLUSH W/ SURFACE 1' - 0" MAINTAIN FINISH GRADE BEYOND WITHIN 24" OF WALKING SURFACE NEW CONCRETE STAIRS, CalDAG COMPLIANT CBC 11B-505.10.2 1 3/4" DIAMETER CIRCULAR PIPE HANDRAIL (1 1/2" - 2" PER CBC 11B-505.7) CBC 11B-505.2: TOP OF HANDRAIL @ 36" (34" - 38", CONSTANT HT.) 2 A-6 CBC 11B-505.4 CBC 11B-505.3 1/2" RADIUS AT NOSING. SLOPE RISER 1 1/2' (E) CONC. PORCH SURFACE 1 A-6 0' - 4" 6" HIGH CURB 0' - 6 3/8" CBC 11B-505.10.3 CBC 11B-505.2 CBC 1009.2 CBC 11B-505.3 CBC 1009.7.4 CBC 11B-505.4 CBC 1009.7.5 CBC 11B-505.7 CBC 1009.7.5.1 CBC 11B-505.9 CBC 1009.8 CBC 11B-505.10 CBC 1009.9.1 CBC 11B-505.10.2 CBC 1009.9.2 Nosing and riser profile radius of curvature or beveling shall not exceed 9/16". The riser shall be solid, and vertical or sloped at an angle not exceeding 30 degrees from vertical. EXCEPTION 3) Solid risers are not required for spiral stairways that comply with Section 1009.12 4" Compacted Crushed Gravel Base, ASTM D448 #57. 2" Bedding, ASTM D448 #8 CBC 1009.9.1 6" Concrete Edge CBC 1009.9.2 Stairway treads and landings shall not be sloped steeper than 1 unit vertical in 48 units horizontal. Outdoor Stairways and approaches shall be designed so that water will not accumulate on walking surfaces. 5 PERVIOUS CONCRETE WALKWAY - CROSS SECTION 1" = 1'-0" 8/12/2015 9:33:42 AM N. 0 T E 10 - 3 1 - 2 R O F CA L I FO C-33938 D A R CH CE IT N E BARKE D I 4" EQ 4' - 3" Sim CBC 11B-405.9.2 Stair Riser shall be 7" max, 4" min. Rectangular Tread depth shall be 11" min., measured nosing-to-nosing. Rectangular shaped Stair Tread depth and Riser heights, within any flight of stairs, shall not vary by more than 3/8". Where the bottom or top riser adjoins a public way, walkway, or driveway, the bottom or top riser is permitted to be reduced along the slope to less than 4" in height. The height variation where the riser adjoins the walkway or driveway shall not exceed 1 unit in 12 units. At risers of such non-uniform height, the tread nosing shall have a distinctive marking stripe, different from any other marking on the stair flight. The stripe width shall be between 1" min. and 2" max. It shall have a slip-resistant surface and shall be visible in descent of the stair. CBC 1009.7.5.1 The Nosing projection shall not exceed 1 1/4" CBC 1009.8 Stairway Landings shall not be narrower than the stairway they serve. The minimum landing length in the direction of travel shall equal the stairway width, BUT need not exceed 48". Doors opening onto a landing shall not swing through more than 1/2 of the required landing width, and when fully open shall not project more than 7" into the landing. Pervious Concrete Walkway 3 A-7 ACCESSIBLE STAIR SECTION 1/2" = 1'-0" RAMP CROSS SECTION 1" = 1'-0" 12" Min. Compacted Crushed Gravel Sub-Base, ASTM D448 #2. EQ 0' - 6 3/8" 2' - 0" 2' - 4" LINE OF (E) CONC. STAIRS 4 CBC 11B-505.10.3 0' - 11" 8 Sim COMPACTED FILL 3' - 0" RETURN HANDRAIL TO WALL (N) CONCRETE SURFACE WITHIN 1/2" OF INSIDE FIN. FLOOR. SLOPE 1/4" PER 1 Ft. SALT FINISH OR EQUIV. SLIP RESISTANCE. 12" 2' - 9" CBC 1009.2 Ramp handrails shall extend 12" min., horizontally, beyond the top and bottom of ramp run. Stairway Top Extension: Stairway handrails shall extend 12" horizontally beyond the top-tread nosing, and shall return to a wall, guard, landing surface, or shall be continuous to the handrail of an adjacent stair flight. Stairway Bottom Extension: Stairway shall extend beyond the bottom-tread nosing, at the slope of the handrail, a distance equal to one tread depth, and then another 12" horizontally at a height equal to that of the sloping portion of the handrail, as measured at the tread nosing. (See Fig. 11B-505.10.3). Handrail extension shall return to a wall, guard, landing surface, or shall be continuous to the handrail of an adjacent stair flight. A-6 A-6 CBC 11B-505.4 SHEET NUMBER: 2 0' - 2 1/2" CLEAR, BEHIND RAILING 0' - 0 1/4" / 1' - 0" F.F. -0.5 in 0' - 1 1/16" / 1' - 0" 1/2"x 5 1/2" CORK EXPANSION JOINT MATERIAL --CONCRETE SLAB OVERLAY TO RAISE FINISH SURFACE FOR CalDAG COMPLIANCE. --CONCRETE per ENGINEERS SPEC. F.F. 0.0 in PROJECT NO: Project Number CBC 11B-404 CBC 11B-505.3 PROJECT ISSUE DATE: Issue Date A-6 081-131-20 1 CBC 11B-505.2 0' - 1 1/2" NEW CONCRETE WALKWAY SEE " ACCESSIBLE RAMP & STAIR PLAN" A.P.N.: EXPANSION JOINT CAULKING/SEALER DESIGNED BY: Designer 0' - 6" NEW 26 Ga. GALV. SHT. MTL. STUCCO DRIP EDGE. ACCESSIBLE RAMP SECTION AT ENTRY 6 1/4" = 1'-0" As indicated CBC 11B-405.9.2 SCALE: 26 Ga GALVANIZED SHT. MTL. FLASHING O/ BITUTHENE MEMBRANE.ZEOVERLAP FOUNDATION 3" MIN. 13230 CENTRAL AVENUE BOULDER CREEK, CA 95006 CBC 11B-405.5 13230 CENTRAL AVENUE BOULDER CREEK, CA 95006 OFFICE: 831 338-7222 REMOVE (E) STUCCO BOTTOM EDGE ENOUGH TO FOLLOW THE LINE OF THE (N) CONC. SURFACE. INSTALL (N) FLASHINGS, PATCH & FINISH STUCCO Thresholds shall be 1/2" max. and shall be beveled 1:2 rise:run. Swinging door & gate surfaces within 10" above the finish floor shall have a smooth hard surface on the push side extending the full width of the door. Clear WIDTH of a ramp shall be 48" min. EXCEPTION 2: Handrails may project into the req'd. width 3 1/2" max. at the rail height. To prevent wheel entrapment, provide a 2" min. high curb or barrier that prevents passage of a 4" dia. sphere. Handrails shall be provided on both sides of stairs and ramps. Handrails shall be continuous within full length of each stair flight or ramp run. Inside handrail on switchback or dogleg shall be continuous. The top of handrails shall be at a consistent height, 34" min. and 38" max. above walking surfaces, stair nosing, and ramp surface. A handrail with circular cross section shall have an outside diameter of at least 1 1/2" min. and 2" maximum. Handrails shall not rotate within their fittings. Handrails shall extend beyond, and in the same direction of stair flights and ramps in accordance with all subsections of 11B-505.10. EXCEPTIONS: 1) Extensions ar not required at the inside turn of a switchback or dogleg. ACCESSIBLE MAIN ENTRY, STAIRS & RAMP CBC 11B-404.2.5 CBC 11B-404.2.10 SEISMIC UPGRADE & ACCESSIBILITY IMPROVEMENT CalDAG/ADA THRESHOLD @ MAIN ENTRY 1 1/2" = 1'-0" CONTACT: KEVIN McCLISH 1 Description POWER DRIVEN FASTENERS Date EXPANSION JOINT CAULKING/SEALER RE A ST Rev. 16 Ga. GALV. SHT. MTL. CURB. PROVIDE 1/2" WEEP HOLES @ EA. CORNER PROJECT: EDGE-BARRIER @ 2" ABOVE FIN. SURFACE per CBC 11B-405.9.2 CBC 11B-404.2.10 OWNER: NEW PORCH SURFACE SMOOTH KICK-SURFACE EXTENDING FULL WIDTH OF DOOR. 0' - 0 1/2" max. 1/2"x 4" CORK EXPANSION JOINT O/ 26 Ga. GALV. SHT. MTL. FLASHING O/ BITUTHENE MEMBRANE HANDRAIL PER CBC 11B-505: CBC 11B-505.2: TOP OF HANDRAIL @ 36" (34" - 38", CONSTANT HT.) CBC 11B-505.10.1: 12" EXTENSION BEYOND TOP @ BOTTOM. SHEET TITLE: 0' - 0 1/8" max. CBC 11B-404.2.5 Revision Schedule NEW CalDAG COMPLIANT THRESHOLD. SEE CBC FIG. 11B-303.3 Keynote (309.4): Operable parts of door shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5 lbs. max. Operable parts shall be between 34" and 44" A.F.F. (404.2.3): Doors shall provide 32" min. clear width with doors open 90 degrees. There shall be no projections into the required width below 34". Above 34", projections shall not exceed 4". (404.2.5): Thresholds shall be 1/2" max. and shall be beveled 1:2 rise:run. (404.2.7): Door pulls shall be between 34" min. & 44" max. A.F.F. (404.2.9): The force required for pushing or pulling open a door or gate shall be 5 lbs. max. (404.2.10): Swinging door & gate surfaces within 10" above the finish floor shall have a smooth hard surface on the push side extending the full width of the door. LI C DA V --NEW CONCRETE RAMP, w/ #4 R.B. @ 12" O.C. EA. WAY --2500 PSI MIN. @ 28 DAYS. 3/4" MAX. AGG., 4" NAX. SLUMP --RAMP SLOPE NOT STEEPER THAN 1 INCH PER FOOT --SEE "ACCESSIBLE RAMP PLAN Key CBC 11B-404 15 CalDAG COMPLIANT DBL. ENTRY DOOR T EC W LE IA COMPACTED CRUSHED GRAVEL SUB-BASE, ASTM D448 #57 SHEET KEY NOTES N 4" Bedding, ASTM D448 #8 2 CalDAG REQUIREMENTS @ LAVATORY 3/4" = 1'-0" 3 STAIR SECTION N.T.S. MIRROR, MATCH LAV. WIDTH CBC 11B-603.3 1' - 0" 0' - 6" 1' - 0" 3' - 6" 2' - 10" 0' - 8" SHEET NUMBER: 12 " Rev. 6" 3/8" 5/8" 12" 11 Womens Restroom - Wall Mount 6" = 1'-0" 12 Womens Restroom - Door Mount 3" = 1'-0" 13 Mens Restroom - Wall Mount 6" = 1'-0" 14 8/12/2015 9:33:43 AM N. 0 T E 10 - 3 1 - 2 R O F CA L I FO WOMEN'S WEST WALL 1/2" = 1'-0" Revision Schedule 9 1' - 8" 1' - 9" Tissue Dispenser CBC 11B-604.7 CBC 11B-604.4 C-33938 D A R CH CE IT N E BARKE D I CBC 11B-604.5.1 CBC 11B-604.5.2 WOMEN'S SOUTH WALL 1/2" = 1'-0" 6" 8 2' - 0" 1' - 8" Toilet Seat ht. CBC 11B-604.8.1.4 MEN'S SOUTH WALL 7 1/2" = 1'-0" 1' - 6" 2' - 10" Grab Bar ht. CBC 11B-604.7 CBC 11B-604.4 1' - 6" 0' - 9" Toe Space, CBC 11B-604.8.1.4 1' - 8" Toilet seat ht. 2' - 10" Grab bar ht. 1' - 5" max. 0' - 9" Toe space CBC 1210.2 CBC 11B-605 1' - 9" min. Tissue dispenser CBC 11B-604.5.2 0' - 4" 1' - 0" 0' - 6" CBC 1210.2 2' - 0" 4' - 0" Height of smooth, hard, non-absorbant surface 1' - 6" CBC 11B-604.7 1' - 6" 3/8" 5/8" MEN'S EAST WALL 6 1/2" = 1'-0" 1' - 6" 0' - 4" CBC 11B-606.5 CBC 1210.2 CBC 11B-606.6 4' - 0" Height of smooth, hard, non-absorbant surface 6' - 8" CBC 11B-606.4 4' - 0" 2' - 10" Max. ht. @ leading edge CBC 11B-606.3 CBC 11B-604.4 CBC 11B-606.5 Exposed water supply and drain pipes under lavatories shall be insulated or otherwise protected. CBC 11B-606.6 The centerline of lavatories shall be at least 18" from an adjacent wall. Mens Restroom - Door Mount 3" = 1'-0" 15 Accessible Route 6" = 1'-0" 081-131-20 PROJECT NO: Project Number BATHROOM UPGRADE TO CalDAG STANDARDS 3/8" = 1'-0" PROJECT ISSUE DATE: Issue Date 5 A.P.N.: FIGURE 11B-306.3 DESIGNED BY: Designer 1' - 0" A-7 CBC 11B-604.7 As indicated 9" Min. 27" Min. NOTE: DIMENSIONS ARE INTENDED TO REPRESENT ACCESSIBILITY CODE CLEARANCE REQUIREMENTS. AS SUCH THEY ARE KEYED FACE-TO-FACE OF WALLS AND PARTITIONS. 29" Min. 2' - 0" 1' - 0" CBC 11B-604.5.1 1' - 6" 5' - 0" Clear WOMEN'S RESTROOM CBC 11B-604 34" Max. CBC 11B-604.5.2 CBC 11B-604.8.1.2 SCALE: 9 13230 CENTRAL AVENUE BOULDER CREEK, CA 95006 CBC 11B-604 13230 CENTRAL AVENUE BOULDER CREEK, CA 95006 OFFICE: 831 338-7222 8" Min. ACCESSIBILITY UPGRADE PLANS & DETAILS 1' - 2" 1' - 6" 11" Min. SEISMIC UPGRADE & ACCESSIBILITY IMPROVEMENT Drinking Fountains. e.g. Elkay hi lo model EDFPBM117RAC, EDFPB117RAC, or EDFP217FC CBC 11B-603.3 Mirrors above lavatories shall be installed with bottom edge at 40" max. A.F.F. Mirrors not located above lav. shall be installed with bottom edge 35" max. A.F.F. CBC 11B-604 Water closets & toilet compartments. See Fig.604.8.1.1.2 "Manuevering Space with Side Opening Door". CBC 11B-604.4 Toilet & seat height. Seat to be mounted @ 17" A.F.F. e.g. Toto CT708E Commercial wall-mounted flushometer toilet, 1.28 GPF, automatic flush. CBC Grab Bars @ side wall: 42" min. long, located 11B-604.5.1 12" max. from rear wall, extending 24" min. in front of toilet. Between 33" min. & 36" max. A.F.F. CBC Grab Bars @ rear wall: 36" long min., 12" min. 11B-604.5.2 from centerline of toilet on one side, 24" min. on the other side. Between 33" min. & 36: max. A.F.F. CBC 11B-604.7 Toilet Tissue Dispenser shall be 7" min & 9" max. in front of the toilet. The outlet shall be below the grab bar & 19" min. A.F.F. CBC Toilet Compartment Doors to be 34" wide clear 11B-604.8.1.2 CBC Side partition shall provide Toe Clearance of 9" 11B-604.8.1.4 A.F.F. CBC 11B-605 Urinals, See Figure 605.2. CBC 11B-606 Lavatories & Sinks. e.g. Toto LT307 ADA Compliant wall-hung lavatory CBC 11B-606.4 Lavatory faucets shall comply with CBC 11B-309(.4): Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required shall be 5 lbs. max. Hand operated metering faucets shall remain open for 10 seconds min. CONTACT: KEVIN McCLISH 8 A-7 CBC 11B-602 BUILDING ACCESSABILITY PLAN 1/8" = 1'-0" 1 1' - 6" A-7 3' - 0" Clear 6 Sim CBC 11B-304.3.2 1 5 A-7 DETAIL 11-A9, SIGN: Women's W.C.-Wall Mounted 5' - 3" 1/500 DN Description 4' - 0" DETAIL 12-A9, SIGN: Women's W.C.-Door Mounted # Req'd. 1 1 2 1 1 6 1/2" Max. 1' - 6" 34" x 80" Single Flush Metal Door with Baked Enamel Finish. CBC 11B-404.2.3 Factor 1/(2x125) 1/(2x125) 1/(2x65) 1/(2x200) 1/(2x200) RE A ST Date 6' - 9" 4' - 9 1/2" 1.5 gpm@60psi Fixture W.C.-M: Urinals W.C.-F: Lav.-M Lav.-F: DrinkingFountain MENS BATH 3' - 10" NEW 2x6 WOOD FRAME WALL CBC 11B-606 EXISTING BATHROOM WALLS & FIXTURES TO BE DEMOLISHED AS SHOWN CLOS.: 73 sf LOAD FACTOR: 300 OCC: 0.24 CBC 11B-604.5.1 OFFICE BUSINESS: 41 sf LOAD FACTOR: 100 OCC: 1 PLUMBING FIXTURED REQ'D. (CPC) Occ. Load Assembly: 106 Other:: 5 Total: 111 1' - 6" 0' - 4" 1' - 6" MEN'S RESTROOM 2' - 0" 9 Sim CBC 11B-604 1' - 0" 5' - 0" Clear A-7 TRAINING RM. #1 ASSEMBLY: 1083 sf LOAD FACTOR: 15 OCC: 72 PROJECT: CBC 11B-602 CBC 11B-604.5.2 CBC 11B-604.8.1.2 CBC 11B-404 1' - 6" 1' - 6" WOMENS BATH 1' - 6" 3' - 0" Clear 7 A-7 STO: 69 sf LOAD FACTOR: 300 OCC.s: 0.23 OWNER: 3' - 11 1/2" NEW 2x6 Wood Frame Plumbing Wall 4' - 0" CBC 11B-605 0' - 1" STO: 77 sf LOAD FACTOR: 300 OCC.s: 0.25 SHEET TITLE: 0' - 4" 34" x 80" Single Flush Metal Door with Baked Enamel Finish. CBC-11B-404.3.2 DETAIL 13-A9, SIGN: Men's W.C.-Wall Mounted. 6 CBC 11B-404 LI C DA V DETAIL 14-A9, SIGN: Men's W.C.-Door Mounted 1.5 gpm@60psi 1' - 6" DN Keynote T-Shaped Turning Space: Shall fit within a 60" square, min. "Arms" & "Leg" shall be 36" wide min. and may include knee & toe clearance space. See Fig. 304.3.2 (309.4): Operable parts of door shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5 lbs. max. Operable parts shall be between 34" and 44" A.F.F. (404.2.3): Doors shall provide 32" min. clear width with doors open 90 degrees. There shall be no projections into the required width below 34". Above 34", projections shall not exceed 4". (404.2.5): Thresholds shall be 1/2" max. and shall be beveled 1:2 rise:run. (404.2.7): Door pulls shall be between 34" min. & 44" max. A.F.F. (404.2.9): The force required for pushing or pulling open a door or gate shall be 5 lbs. max. (404.2.10): Swinging door & gate surfaces within 10" above the finish floor shall have a smooth hard surface on the push side extending the full width of the door. 15 CBC 11B-606 Key CBC 11B-304.3.2 KITCHEN: 349 sf LOAD FACTOR: 200 OCC. LOAD: 2 IA GARAGE TRAINING RM. #2 ASSEMBLY: 503 sf LOAD FACTOR: 15 OCC: 34 T EC W LE N SHEET KEY NOTES