tomorrow`s solutions today
Transcription
tomorrow`s solutions today
++++++++ ++++++++ ++++++++ ++++++++ ++++++++ ++++++++ ++++++++ ++++++++ TOMORROW’S SOLUTIONS TODAY www.faiveleytransport.com References trains – locomotives 2 Pegasus Integrated System CRH1-380 – Zefiro China – high speed train NTV – high speed train EMU V 250 CRH3-380 (380A) – high speed train EMU EJ 671 RGV2N2 – high speed train ÖBB1216 locomotive 109 E three-system locomotive EMU EJ 575 ES60U3 Eurosprinter KTX II – high speed train SEPTA EMU AGC EMU NAT EMU DMU 219 Bari AC6000 CW locomotive Pendolino 2ES6 Prima FRET locomotive FRET Diesel locomotive 3 6 7 8 9 10 12 13 14 16 17 18 19 20 21 22 23 24 25 26 27 trams 29 CITADIS tram Tram for St. Petersburg Vario LF tram Škoda 14T tram, Prague 30 31 32 33 metro 34 Metro Delhi MNG – Metro Milano M8 Tap Changer Metro Mexico 35 36 37 38 trolleybuses 39 Trolleybus Škoda TR 24 Pilsen Solaris Trolino 12 Škoda 24 TR, Škoda 25 TR Trolleybuses Riga, Latvia Trolleybuses Venezuela Solaris Trolino 18 40 41 42 44 45 46 1 we make the wheel go round trains – locomotives Pegasus Integrated System CRH1-380 – Zefiro China – high speed train NTV – high speed train EMU V 250 CRH3-380 (380A) – high speed train EMU EJ 671 RGV2N2 – high speed train ÖBB1216 locomotive 109 E three-system locomotive EMU EJ 575 ES60U3 Eurosprinter 2 KTX II – high speed train SEPTA EMU AGC EMU NAT EMU DMU 219 Bari AC6000 CW locomotive Pendolino 2ES6 Prima FRET locomotive FRET Diesel locomotive www.faiveleytransport.com Pegasus Integrated System trains – locomotives Faiveley Transport Classical layout Length 5m Pegasus layout Length 2,3m 3 we make the wheel go round Pegasus Integrated System Faiveley Transport switchonic: electronic part (under roof) pantograph auxiliary compressor easyswitch switchonic: pneumatic part AC protection AC roof line 4 trains – locomotives www.faiveleytransport.com 5 we make the wheel go round CRH1-380 – Zefiro China – high speed train Faiveley Transport Qingdao (QFS), China pantograph CX PG Purpose: supplies voltage to the vehicle from the traction system Operating temperature: 6 -25°C to +70°C Working speed: 380 km/h Rated current: 500 A (AC) Rated voltage: 25 kV www.faiveleytransport.com NTV – high speed train trains – locomotives Alstom Transport, France pantograph cX nG 3 kv Purpose: pantograph CX NG 25 kV supplies voltage to the vehicle from the traction system Operating temperature: Rated voltage: Rated current: Working speed: -25°C to +70°C DC 3 kV 2500 A 250 km/h Purpose: supplies voltage to the vehicle from the traction system Operating temperature: -25°C to +70°C Rated voltage: AC 25 kV Working speed: 300 km/h 7 we make the wheel go round EMU V 250 Ansaldobreda, Italy roof disconnector roof disconnector 5 OSAD 11 Purpose: disconnects the circuits of traction vehicles Operating temperature: Rated voltage: -30°C to +70°C 25 kV Maximum voltage: 29,5 kV AC 13 OSAD 7 Purpose: disconnects the circuits of traction vehicles Operating temperature: Rated voltage: 25 kV Maximum voltage: 29,5 kV AC pantograph pantograph AX NG Purpose: supplies voltage to the vehicle from the traction system Operating temperature: Rated voltage: Type: Rated current: Working speed: 8 -30°C to +45°C 3/1,5 kV DC 2900 A 140 km/h -30°C to +70°C AX NG Purpose: supplies voltage to the vehicle from the traction system Operating temperature: Rated voltage: Type: Rated current: Rated speed: -25°C to +70°C 25 kV AC 800 A 275 km/h www.faiveleytransport.com CRH3-380 (380A) – high speed train trains – locomotives Faiveley Transport Qingdao (QFS), China pantograph CX PG Purpose: supplies voltage to the vehicle from the traction system Operating temperature: Working speed: -25°C to +70°C 380 km/h Rated current: 1000 A (AC) Rated voltage: 25kV 9 we make the wheel go round EMU EJ 671 ŠKODA Transportation pantograph AX NG Purpose: supplies voltage to the vehicle from the traction system Operating temperature: Working speed: resistor Rated voltage: 10 1800A (DC) / 1000A (AC) Rated voltage: 25kV AC / 3kV DC 28 SMD 15 functions as the charging resistor of the capacitor filter of traction vehicles Operating temperature: 160 km/h Rated current: contactor ORP 47 Purpose: -30°C to +40°C Purpose: Operating temperature: designed to make and break DC and AC circuits -33°C to +45°C -35°C to + 45°C Rated current: 400A 3000 V DC Rated voltage: 3000 V DC www.faiveleytransport.com roof disconnector indicator relay 15 OSAD 7 3 RND 6 functions as the indicator of current system in the traction vehicles Operating temperature: -35°C to + 45°C Rated DC voltage: 3000V DC Maximum voltage: 4200V DC disconnecting switch Purpose: Operating temperature: SPO 1M4-6L24S6 disconnects the circuits of traction vehicles -33°C to +45°C Rated voltage: 25kV AC/3000 V DC Purpose: Maximum voltage: 29kV AC/4200 V DC Operating temperature: contactor Purpose: Operating temperature: 3000 V Maximum voltage: 4200 V 11 SMD 32 -33°C to +45°C 800A Rated voltage: 3000 V DC Purpose: controller Operating temperature: KRD 75 Operating temperature: Rated voltage: 1000 V Maximum voltage: 1200 V contactor 2 SMD 34 Purpose: Operating temperature: functions as the charging resistor of the capacitor filter of traction vehicles Rated voltage: 400 A -35°C to +45°C 24V DC (+25%; -30%) 1 ORS 26 Operating temperature: -30°C to +40°C controls the traction vehicle resistor Purpose: designed to make and break DC and AC circuits Rated voltage: Rated current: Purpose: 600 A contactor designed to make and break DC and AC circuits Rated current: -33 °C to +45 °C Rated voltage: Rated current: 4 SVD 14 reverses the circuits of the locomotive trains – locomotives Purpose: designed to make and break DC and AC circuits -30°C to +40°C Rated current: 300A Rated voltage: 3000 V AC / 50 Hz Maximum voltage: 3600 V AC -35°C to +45°C 3000 V DC contactor 7 SMD 30 resistor 2 ORS 13 Purpose: functions as the charging resistor of the capacitor filter of traction vehicles Operating temperature: Rated DC voltage: Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature: -30°C to +40°C -35°C to +45°C Rated voltage: 1000 V 3000 V DC Rated current: 800 A 11 we make the wheel go round RGV2N2 – high speed train Alstom Transport, France pantograph CX PG Operating temperature: Rated voltage: Type: Rated current: Working speed: 12 roof disconnector OSAD 14 -25°C to +70°C 1,5 kV DC 2900 A 275 km/h Purpose: Operating temperature: disconnects the circuits of traction vehicles -40 °C to +70 °C Rated voltage: 25 kV AC Maximum voltage: 29 kV AC www.faiveleytransport.com ÖBB1216 locomotive trains – locomotives Siemens, Germany reverser disconnecting switch 7 PPAD 24 SPO 2+1 Purpose: reverses the circuits of the locomotive Rated voltage: 3000 V Rated current: 1200 A Control voltage: 110 V reverser 2 PPAD 23 Purpose: grounds the circuits Purpose: Operating temperature: Control voltage: reverses the circuits of traction vehicles -30°C to +75°C 110V DC +25% -30% of traction vehicles Operating temperature: Control voltage: -30°C to +75°C 110V DC +25% -30% 13 we make the wheel go round 109 E three-system locomotive ŠKODA Transportation, ŠKODA Electric roof disconnector reverser 10 OSAD 7 1 PPAD 44 Purpose: performs the off-load reversing of the electric circuits of traction vehicles Operating temperature: Purpose: disconnects and grounds the electric circuits of traction vehicles Operating temperature: Rated voltage: 14 -35°C to +45°C 25 kV Rated DC voltage: Rated current: Control voltage: -30°C to +45°C 3000V DC 1000A 24V DC www.faiveleytransport.com resistor earthing switch RU 7 Purpose: Purpose: functions as the charging resistor of the capacitor filter of traction vehicles Operating temperature: controller -35°C to +45°C Rated voltage: 3 000 V DC 3000 V DC Max. voltage: 4 000 V DC disconnecting switch KRD 75 resistor SPO5 M4 Purpose: 2 ORS 13 reverses the circuits of the locomotive Operating temperature: Purpose: of traction vehicles Operating temperature: -35°C to +45°C Rated voltage: Purpose: -40°C to +70°C functions as the charging resistor of the capacitor filter of traction vehicles Rated voltage: 3000 V Operating temperature: Maximum voltage: 4000 V Rated DC voltage: -35°C to +45°C 3000 V DC controls the traction vehicle Operating temperature: Rated voltage: -35°C to +45°C +24V DC (+25%; -30%) lock system resistor indicator relay ORP 50 Purpose: ZS R 3 RND 6 functions as the charging resistor Purpose: functions as the indicator of current of the capacitor filter of traction vehicles Operating temperature: Purpose: performs safety earthing of the electric circuits trains – locomotives ORS 33 forms part of the safety interlocking system of traction vehicles Operating temperature: Rated voltage: Maximum voltage: - 35°C to + 45°C system in the traction vehicles Operating temperature: -35°C to + 45°C 3000 V DC Rated DC voltage: 3000V DC 4,2 kV DC Maximum voltage: 4200V DC -35°C to +45°C Rated voltage: 24 V Rated current: 150 mA pantograph CX NG Purpose: supplies voltage to the vehicle from the traction system Operating temperature: Rated voltage: Type: Nominal current: Working speed: -30°C to +50°C 3/15/25 kV AC/DC 2700 A (3 kV) 220 km/h 15 we make the wheel go round EMU EJ 575 ŠKODA Transportation contactor pantograph AX NG 11 SMD 32 Purpose: Purpose: supplies voltage to the vehicle from the traction system Operating temperature: 16 -30°C to +40°C Operating temperature: designed to make and break DC and AC circuits -30°C to +40°C Rated voltage: 1000 V 1200 V Rated voltage: AC 25 kV Maximum voltage: Working speed: 160 km/h Rated current: 400 A www.faiveleytransport.com ES60U3 Eurosprinter trains – locomotives Siemens, Germany reverser 10 PPAD 24 Purpose: Operating temperature: Rated voltage: Control voltage: reverses the circuits of the traction vehicle -35°C to + 45°C 3000 V DC 110 V DC 17 we make the wheel go round KTX II – high speed train Hyundai Rotem, Korea controller KRD 99 controller 2 KRD 69 Purpose: controls the braking of traction vehicles Purpose: Operating temperature: Operating temperature: Rated voltage: 18 -35°C to +55°C 72 V DC Rated voltage: controls the traction, braking and reversing of traction vehicles -35°C to +55°C 72 V DC www.faiveleytransport.com SEPTA EMU trains – locomotives Mitsubishi Electric, Japan controller 1 KRD 100 Purpose: Operating temperature: Rated voltage: controls the traction mode of the vehicle -25°C to +40°C 37,5 V DC 19 we make the wheel go round AGC EMU Bombardier Transportation, France controller KRD 69 pantograph AX Purpose: designed to control the traction, braking and reversing of traction vehicles Operating temperature: Rated voltage: Purpose: -25°C to +70°C 72 V DC +25% -30% from the traction system Operating temperature: Rated voltage: controller KRD 70 Purpose: designed to control the pantographs of traction vehicles Operating temperature: Rated voltage: 20 -25°C to +70°C 72 V DC +25%, -30% supplies voltage to the vehicle -25°C to +70°C 25/1,5 kV www.faiveleytransport.com NAT EMU trains – locomotives Bombardier Transportation, France pantograph AX Purpose: supplies voltage to the vehicle from the traction system Operating temperature: Rated voltage: Type: Rated current: Working speed: -25°C to +70°C 1,5/25 kV AC/DC 1800 A/250 A 140 km/h +10% 21 we make the wheel go round DMU 219 Bari PESA, Poland controller KRD 34 Purpose: controls the traction mode of the traction vehicle Operating temperature: controller KRD 75 Purpose: controls the traction vehicle Operating temperature: Rated voltage: 22 -35°C to +45°C 24V DC (+25%; -30%) -30°C to +40°C Rated voltage: 24 V ss Rated current: 1A www.faiveleytransport.com AC6000 CW locomotive trains – locomotives GE Transportation, USA reverser 3 PPAD 28 Purpose: Operating temperature: Rated voltage: Control voltage: reverses the circuits of traction vehicles -40°C to +90°C 1500 V DC 64 V DC, 76 V DC 23 we make the wheel go round Pendolino controller Alstom Ferroviaria KRD 48 Purpose: designed to control the speed of traction vehicles Operating temperature: -40 °C to +60 °C Rated voltage: 24 Vss Rated current: 10 A termický controller KRD 49 Purpose: designed to set the traction force and reverse the direction of travel roof disconnector of the traction vehicle 7 OSAD 11 Operating temperature: -40 °C to +60 °C Rated voltage: 24 Vss Rated current: 10 A thermal earthing switch RUM 5 Purpose: provides safety earthing of the electric Purpose: Operating temperature: Rated voltage: Maximum voltage: 24 disconnects the circuits of traction vehicles -30°C to +70°C 25 kV 29,5 kV AC power circuits of traction vehicles Operating temperature: -25 °C to +70 °C Nominal voltage: 3000 V DC Maximum operating voltage: 4000 V DC www.faiveleytransport.com 2ES6 trains – locomotives Sinara, Russia pantograph SX 2100 Purpose: supplies voltage to the vehicle from the traction system Operating temperature: Rated voltage: Maximum voltage: Working speed: -50°C to +60°C 3000 V 4000 V 140 km/h 25 we make the wheel go round Prima FRET locomotive controller Alstom Transportn,France KRD 55 Purpose: controls the traction and braking modes of traction vehicles Operating temperature: -25 °C to +75 °C Rated voltage: 110 V DC Rated current: 10 A controller KRD 46 Purpose: controls the traction and braking modes of traction vehicles Operating temperature: roof disconnector OSAD 14 -40 °C to +70 °C battery containers FRET Purpose: disconnects the circuits of traction vehicles Operating temperature: -40 °C to +70 °C Rated voltage: 25 kV AC Maximum voltage: 29 kV AC pantograph SX NG Purpose: supplies voltage to the vehicle from the traction system Operating temperature: -25°C to +45°C Rated voltage: Working speed: 26 15/25 kV 140 km/h www.faiveleytransport.com FRET Diesel locomotive trains – locomotives Alstom Transportn,France controller controller KRD 72 Purpose: controller KRD 55 designed to control the traction and Purpose: KRD 73 designed to control the braking braking modes of traction vehicles Operating temperature: -25°C to +75°C Rated voltage: 24V DC Rated current: 10A thermal of traction vehicles Operating temperature: Rated voltage: Rated current: : -25°C to +75°C Purpose: designed to control the horn Operating temperature: -25°C to +75°C 110 V DC Rated voltage: 24V DC 10 A thermal Rated current: 10A thermal 27 we make the wheel go round 28 www.faiveleytransport.com trams CITADIS tram Tram for St. Petersburg Vario LF tram Škoda 14T tram, Prague 29 we make the wheel go round CITADIS tram Alstom Transportation, France controller controller 1 KRD 57 2 KRD 57 5 KRD 57 Purpose: designed to control the traction, braking Purpose: designed to control the traction, braking Purpose: designed to control the traction, braking and emergency braking modes of the tram and emergency braking modes of the tram and emergency braking modes of the tram Operating temperature: Rated voltage: 30 controller -25°C to +70°C 24 Vss Operating temperature: Rated voltage: -25°C to +70°C Rated voltage: 24 V DC 24 V DC Rated current: 10 A www.faiveleytransport.com Tram for St. Petersburg trams PTMZ, Russia controller KRD 115 Purpose: Operating temperature: controls the traction vehicle -30°C to + 60°C Rated voltage: 750 Vss Rated current: 450 A main switch VPD 14 pantograph EPDE 16-2600 Purpose: Purpose: the EPDE 16–2600 current collectors are designed for trams Operating temperature: provides overcurrent protection of the vehicle -30°C to + 60°C Rated voltage: 600 V DC / 750 V DC Rated voltage: 750 VSS Rated current: 1000 A Rated current: 450 A 31 we make the wheel go round Vario LF tram PRAGOIMEX controller reverser KRD 56 2 PPAD 37 pantograph EPDE 11-2600 Purpose: reverses the circuits of traction vehicles Purpose: designed to control traction vehicles 32 Operating temperature: -30°C to +40°C Rated voltage: Rated voltage: 24 V DC Rated current: Rated current: 1A Operating temperature: Control voltage: -25°C to +50°C Purpose: designed for vehicles supplied from the 1000 V traction system 1000 A Rated voltage: 600 V DC / 750 V DC 24 V DC Rated current: 1 500 A www.faiveleytransport.com Škoda 14T tram, Prague trams ŠKODA Transportation reverser PPAD 51 Purpose: designed to connect/disconnect and to ground the main supply from the current collector of the tram and to ground the auxiliary drives supply Operating temperature: Rated voltage: Rated current: Control voltage: -25°C to +50°C 1000 V 1000 A 24 V DC 33 we make the wheel go round metro Metro Delhi MNG – Metro Milano M8 Tap Changer Metro Mexico 34 www.faiveleytransport.com Metro Delhi metro Bombardier Transportation, India pantograph LX 1800 Purpose: supplies voltage to the vehicle from the traction system Operating temperature: Rated voltage: Type: Working speed: 0°C to +50°C 25 kV AC 85 km/h 35 we make the wheel go round MNG – Metro Milano FIREMA Transporti, Italy pantograph LX 1100 FIREMA Purpose: supplies voltage to the vehicle from the traction system Operating temperature: -25°C to +45°C (cat. T3) Rated voltage: Rated current: Maximum current: 36 750V DC to 1500V DC 800 A to 1600 A 1450 A to 2850 A www.faiveleytransport.com M8 Tap Changer metro Mitsubishi Electric, Japan container 1 BPS 27 Purpose: contains a reverser designed to reverse the circuits of traction vehicles Operating temperature: Rated voltage: -40°C to +55°C 12,5 kV / 25 kv 37 we make the wheel go round Metro Mexico CAF, S.A., Spain controller 2 KRD 108 Purpose: designed to control the traction and braking modes of traction vehicles Operating temperature: Rated voltage: 38 -10°C to +45°C 72 V DC www.faiveleytransport.com trolleybuses Trolleybus Škoda TR 24 Pilsen Solaris Trolino 12 Škoda 24 TR, Škoda 25 TR Trolleybuses Riga, Latvia Trolleybuses Venezuela Solaris Trolino 18 39 we make the wheel go round Trolleybus Škoda TR 24 Pilsen ŠKODA Electric contactor contactor 7 SMD 30 5 SMD 33 Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature: Rated voltage: 1000 V Rated current: 800 A trolleybus current collector TSS 2.5 Purpose: supplies voltage to the vehicle from the traction system Operating temperature: 40 -30°C to +60°C Rated voltage: 750 Vss Rated current: 600 A -30°C to +40°C Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature: -30°C to +65°C Rated voltage: 750 V DC Rated current: 40 A www.faiveleytransport.com Solaris Trolino 12 trolleybuses Trolleybuses for municipal transport companies trolleybus current collector TSS 2.1 Purpose: supplies voltage to the vehicle from the traction system Operating temperature: -30°C to +40°C Rated voltage: 750 V ss Rated current: 600 A main switch VPD 14 Purpose: provides overcurrent protection of the vehicle Operating temperature: -30°C to +60°C Rated voltage: 750 V ss Rated current: 450 A contactor contactor 7 SMD 30 5 SMD 33 Purpose: designed to make and break DC and AC circuits in traction vehicles Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature: Operating temperature: -30°C to +40°C -30°C to +65°C Rated voltage: 1000 V Rated voltage: 750 V DC Rated current: 800 A Rated current: 40 A 41 we make the wheel go round Škoda 24 TR, Škoda 25 TR Škoda Electric contactor 10 SMD 32 Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature: -30°C to +60°C Rated voltage: 750 V DC Rated current: 400 A Maximum vypínací proud: 800 A trolleybus current collector TSS 2.1 resistor ORS 30 Purpose: supplies voltage to the vehicle from the traction system Purpose: Operating temperature: Rated voltage: 42 series, charging and discharging resitors Operating temperature: -30°C to +40°C -35°C to +45°C Rated voltage: 750 V ss 3000 V DC Rated current: 600 A trolleybuses www.faiveleytransport.com contactor 5 SMD 33 Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature: -30°C to +65°C Rated voltage: 750 V DC Rated current: 40 A contactor 7 SMD 30 Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature: -30°C to +40°C Rated voltage: 1000 V Rated current: 800 A 43 we make the wheel go round Trolleybuses Riga, Latvia ŠKODA Electric contactor 7 SMD 30 Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature: -30°C to +40°C Rated voltage: 1000 V Rated current: 800 A contactor 5 SMD 33 trolleybus current collector TSS 2.6 Purpose: supplies voltage to the vehicle Purpose: designed to make and break DC and AC from the traction system Operating temperature: 44 circuits in traction vehicles -40°C to +60°C Operating temperature: -30°C to +65°C Rated voltage: 750 V ss Rated voltage: 750 V DC Rated current: 600 A Rated current: 40 A www.faiveleytransport.com Trolleybuses Venezuela trolleybuses Bombardier Transportation, Spain trolleybus current collector TSS 9.1 Purpose: supplies voltage to the vehicle from the traction system Operating temperature: -30°C to +50°C Rated voltage: 750 V ss Rated current: 600 A 45 we make the wheel go round Solaris Trolino 18 Municipal transport Salzburg, Austria trolleybus current collector TSS 10.2 main switch VPD 14 Purpose: Operating temperature: Purpose: supplies voltage to the vehicle from the traction system Operating temperature: -40°C to +40°C Rated voltage: 750 V ss Rated current: 600 A provides overcurrent protection of the vehicle contactor -30°C to +60°C Rated voltage: 750 V ss Rated current: 450 A 2 SMD 33 contactor SMD 32 Purpose: Operating temperature: 46 designed to make and break DC circuits -30°C to +60°C Purpose: designed to make and break DC circuits in traction vehicles Operating temperature: -30°C to +65°C Rated voltage: 750 V ss Rated voltage: 750 V DC Rated current: 400 A Rated current: 40 A Faiveley Transport Australia Ltd • Rosehill • +61 288 6347 00 • Australia + Faiveley Transport Do Brasil S/A • São Paulo • +55 (11) 6889-6001 • Brazil + Faiveley Transport Canada • Châteauguay • +18 64 27 75 00 0 • Canada + Shanghai Faiveley Railway Technology Co. Ltd. • Shanghai • +86 21 33718866 • China + Faiveley Transport Lekov • Blovice • +420 379 207 111 • Czech Republic + Faiveley Transport Pilsen • Nyrany • +420 379 411 520 540 • Czech Republic + Faiveley Transport Tours • Tours • +33 2 47 32 55 55 • France + Faiveley Transport NSF • Neuville-en-Ferrain • +33 (0)3 20 45 65 46 • France + Faiveley Transport Leipzig GmbH & Co. KG • Schkeuditz • +49 34204 85 300 • Germany + Faiveley Transport India Ltd. • Harita, Hosur • +91 4344 276 761 • India + Faiveley Transport Italia S.p.A. • Piossasco • +39 (0)11 90 44 1 • Italy + Faiveley Transport Polska • Poznan • +48 61 653 64 11 • Poland + Faiveley Transport Russia • Vsevolozhsk City • +7 812 676 59 80 • Russia + Faiveley Transport Korea • Seoul • +82 2564 03 25 • South Korea + Faiveley Transport Ibérica S.A. • Tarragona • +34 977 011000 • Spain + Faiveley Transport Nordic • Landskrona • +46 418 544 00 • Sweden + Faiveley Transport Switzerland – Urs Dolder AG • Hägendorf • +41(0) 62 216 33 88 • Switzerland + Faiveley Transport Tamworth • Tamworth • +44 1 827 308430 • UK + Faiveley Transport Ellcon National • Greenville • +1 864 277 5000 • USA + ++++++++ ++++++++ ++++++++ ++++++++ ++++++++ ++++++++ ++++++++ ++++++++ TOMORROW’S SOLUTIONS TODAY Head office: Faiveley Transport Immeuble Le Delage - Hall Parc - Bat. 6A - 6th floor 3, rue du 19 mars 1962 - 92230 Gennevilliers - France Tel: +33 (0) 1 48 13 65 00 - Fax: +33 (0) 1 48 13 65 54 www.faiveleytransport.com