industrial fans - Twin City Fan and Blower
Transcription
Turning Air Into Solutions. INDUSTRIAL FANS RBO | RBR | RBA | RBW | RBP - CLASS 22 & 32 Catalogue M902 November 2013 IndustrialFans Models - Class 22 & 32 RBO I RBR I RBA I RBW I RBP The Series 900 Industrial Fans manufactured by Twin City Fan & Blower are well suited for installations involving exhaust, material conveying, pollution control, air circulation, and a variety of other industrial applications. The typical performance characteristics for different impellers offered in Series 900 fans are illustrated on page 3. It should be noted that all impellers essentially have overloading characteristic type brake horsepower curves; however, type RBA impellers have this to a lesser degree than other types. RBO Arrangement 8 Twin City Fan & Blower certifies that the Series 900 Model RBO/RBR/RBA/RBW fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. While the general pressure characteristic curve is similar for all Series 900 impellers, the RBA type impeller is considerably more efficient than other Series 900 impellers. Therefore, the RBA impeller is the first choice where brake horsepower savings are important, but the RBA impeller is limited to handling relatively clean air or gases. Efficiency is critical in most applications, and it is important that the fan size is selected so that it will operate at or near its maximum efficiency point. This is particularly important with the units that have lower efficiency in general, such as the RBO and RBW impellers. Twin City Fan & Blower offers a complete series of impellers to meet the needs of most industrial process and material handling applications. Each impeller is statically and dynamically balanced on electronic equipment prior to being assembled in the fan. In addition, each unit is run at or near operating speed after assembly and the balance is fine-tuned as a complete assembly. RB Series Availability SIZE 905 907-909 911-921 923-926 929 933-949 954-960 IMPELLER TYPE RBO RBO RBA, RBW RBO RBA, RBW RBP RBO*, RBA, RBW RBP RBO*, RBA, RBW RBO*, RBA, RBW RBO, RBA, RBW ROTATABLE HOUSING DISCHARGE YES YES YES YES YES YES NO NO NO NO NO REVERSIBLE ROTATION YES YES NO YES NO NO NO NO NO NO NO CLASS 22 ARRANGEMENTS 1,8,9A,9B,10 1,4,8,9A,9B,9F,10 1,4,8,9A,9B,9F,10 1,4,8,9A,9B,9F,10 1,4,8,9A,9B,9F,10 — 1,8,9A,9B,9F,10 — 1,8,9A,9B,9F 1,8,9,9F 1,8,9,9F CLASS 32 ARRANGEMENTS — — — 1,4,8,9,9F 1,4,8,9,9F 1,9,9F 1,8,9,9F 1,9,9F 1,8,9,9F 1,8,9,9F — * Note: RBR is standard on size 926 and larger Class 32 fans. Series 900 fan housings are constructed in all usual arrangements and conform to AMCA Standard 2404-72 (Drive Arrangements for Centrifugal Fans). The fan sizes and impeller diameters conform to AMCA Standard 2402-66 (Sizes for Industrial Centrifugal Fans). AMCA does not have a standard for industrial fans designating class of operation. Twin City Fan & Blower offers three basic categories, based on performance, of industrial 2 fans. Two of the categories are shown in this catalogue: 1. Class 22 – suitable for applications involving performance to approximately 5470 Pa; and 2. Class 32 – for performance to 7950 Pa. A separate supplemental catalogue (Catalogue 911) shows the third category: Class 45 – high pressure fans capable of reaching performance of approximately 11190 Pa. Twin City Fan Catalogue M902 ImpellerTypes RBO Industrial Radial Paddle Impeller: The open type radial paddle impeller design is extremely rugged using heavy-gauge steel components which are jig assembled for accuracy and consistency. All impellers are welded with care to insure the maximum in strength and reliability. RBO impellers are suitable for general handling of coarse, sticky, heavy, and/or abrasive materials. RBR Industrial Radial Paddle Impeller: The RBR impeller is similar to the RBO, with the addition of end rings. RBR construction is standard on size 926 and larger Class 32 fans. RBR impellers are suitable for general handling of coarse, sticky, heavy, and/or abrasive materials. RBO / RBR RBA RBW RBP RBW Industrial Radial Backplate Wool Impeller: The RBW impeller is constructed to prevent paper shreddings, threads from buffing system exhaust, and other similar matter from hanging up on and wrapping around the spiders and blades. Applications include long, stringy or fibrous materials. RBA Industrial Radial Air Handling Impeller: The RBA impeller is a more efficient type of impeller and is used when handling relatively clean air, fumes, vapor exhaust, and air with a light contaminant. The impeller is constructed with heavy-gauge blades welded to both backplate and front ring. RBP Industrial Radial Paper Handling Impeller: This modified RBW impeller features trapezoidal gussets for the extra rugged construction necessary when handling corrugated paper trims, fibrous material, metal trim, and other high impact loading material. A paper deflector cone over the face of the hub helps prevent wrapping of paper around the hub or leading edge of the blades. Rotatable and Reversible Configuration The table on page 2 identifies fans that are rotatable or reversible. A fan available in a rotatable configuration indicates that the fan can be rotated in the field to any of the standard discharge locations. A fan available in a reversible configuration indicates that the impeller rotation can be changed in the field from a clockwise to a counterclockwise direction or vice versa. This is possible only on rotatable housings and requires the impeller housing to be removed and reversed. Consult the factory before reversing a fan. See the chart on page 5 for specific configurations and their designations. All RBP fans are supplied with bearing stop blocks and a relieved inlet transition. The relieved inlet transition smooths the flow of paper trim and similar material through the fan. Breaker tabs are offered as an option on the relieved inlet transition to assist in the breakup of material. Due to the nature of the applications, RBP Class 32 construction is limited to 5470 Pa and RBP Class 45 construction is limited to 7950 Pa. Use RBW performance curves for RBP fans. The RBP fan is not AMCA licensed. Typical Performance Characteristic Curves for Industrial Impellers 80 60 60 40 40 20 20 0 20 40 60 80 100 AIRFLOW IN % WOV 100 80 80 60 60 40 40 20 20 0 20 40 60 80 100 AIRFLOW IN % WOV www.tcf.com 100 100 80 80 60 60 40 40 20 20 0 20 40 60 80 % BRAKE KILOWATT 80 100 % STATIC PRESSURE 100 RBW % BRAKE KILOWATT 100 % STATIC PRESSURE RBA % BRAKE KILOWATT RBO, RBR % STATIC PRESSURE 100 AIRFLOW IN % WOV 3 Arrangements Arrangement 1 Arrangement 1 fans are available in either direct drive (see Arrangement 8 below), or belt driven installations. The belt driven configuration allows the motor to be mounted in any of the four standard motor positions shown on page 5. The choice of a belt driven installation provides greater performance flexibility with the use of belts and sheaves of differing sizes. Arrangement 8 Arrangement 8 fans use a fan shaft and motor direct coupled via a flexible coupling. The integral motor subbase is fabricated of heavy gauge steel and securely reinforced for rigidity. Twin City Fan & Blower can supply impellers in a variety of diameters and differing widths to give the greatest efficiency for any given application. If desired, an Arrangement 1 fan can be set up for direct drive. This requires a concrete motor pedestal to be built in the field. Arrangement 9 Arrangement 9 fans include a motor slide base mounted on the side of the motor pedestal. The motor and drive can be installed at the factory or field installed. Class 22 fans up to size 929 are offered in Arrangements 9A (shorter pedestal for small motors) and 9B (longer pedestals for larger motors). Maximum motor frame sizes for Arrangement 9A and 9B are listed in the table on page 5. Unless otherwise specified, the motor will be installed on the left (L) side of the pedestal on CW fans and on the right (R) side on CCW fans. Arrangement 9F Arrangement 9F (floor mount) fans are recommended when a packaged unit is desired, but required motors are too large to be mounted on the side of the bearing pedestal. In this arrangement, the base is extended to facilitate motor mounting in a horizontal position similar to an Arrangement 1 fan. This arrangement is preferred over Arrangement 9 when larger kilowatt motors are being employed. Unless otherwise specified, the motor will be installed on the left (L) side of the pedestal on CW fans and on the right (R) side on CCW fans. Arrangement 9F requires a separate subbase when vibration isolation is required. Arrangement 10 Arrangement 10 fans are suitable for roof or outdoor installations. A weather cover, as shown, provides complete weather protection for motor, shaft, bearings, and drives. This arrangement is limited to Class 22, sizes 905 through 919. Maximum motor sizes allowable in this arrangement are listed in the table on page 5. Larger fan sizes in this arrangement, or larger motor sizes for smaller fans, may be available on special request from the factory. All usual accessories are available in this arrangement. 4 Twin City Fan Catalogue M902 StandardConfigurations Designations for Rotation and Discharge Clockwise Upblast CW 360 Clockwise Downblast CW 180 Clockwise Top Angular Up CW45 Clockwise Top Horizontal CW90 Clockwise Top Angular Down CW135 Counterclockwise Upblast CCW360 Clockwise Bottom Angular Down CW225 Clockwise Bottom Horizontal CW270 Clockwise Bottom Angular Up CW315 Counterclockwise Downblast CCW180 Counterclockwise Top Angular Up CCW45 Counterclockwise Bottom Angular Down CCW225 Counterclockwise Top Horizontal CCW90 Counterclockwise Bottom Horizontal CCW270 Counterclockwise Top Angular Down CCW135 Counterclockwise Bottom Angular Up CCW315 Direction of rotation is determined from the drive side of the fan. On single inlet fans, the drive side is always considered the side opposite the fan inlet. Direction of discharge is determined in accordance with the diagrams shown above. Angle of discharge references the horizontal axis of the fan, and is designated in degrees above or below that reference axis. On fans inverted for ceiling suspension or side-wall mounting, the direction of rotation and discharge is determined when the fan is resting on the floor. Maximum Motor Frame Size SIZE 905 907 909 911 913 915 917 919 921 923 926 929 933 937 941 945 949 954 960 CLASS 22 9A — 112M 112M 132M 132M 160L 160L 180L 200L 200L 225M 225M — — — — — — — 9B — 132M 160L 160L 180L 180L 200L 225M 225M 225M 250M 250M — — — — — — — 9 — — — — — — — — — — — — 250M 250M 250M 250M 250M 250M 250M Motor Positions CLASS 32 9F — 132M 160L 180M 200M 200M 200L 225M 225M 225M 250M 280S 280M 280M 280M 280M 280M 280M 280M 10 90L 112M 132M 160L 160L 180L 180L 200L — — — — — — — — — — — 9 — — — 160L 180L 180L 200L 225M 225M 225M 250M 250M 250M 250M 250M 250M 250M — — 9F — — — 180L 200L 200L 225M 250M 250M 280M 280M 280M 280M 280M 280M 280M 280M — — The drawing above illustrates motor position standards for Arrangement 1 fans. The location of the motor is determined by facing the drive side of the fan and designating the motor position by letters W, X, Y, or Z. www.tcf.com 5 Accessories Access Doors Bolted and quick-opening access doors are available for easy access to the fan interior for inspection or cleaning. All access doors are gasketed and are constructed with either evenly-spaced studs or heavy duty hinges and handle-type nuts which require no tools to open. Raised bolted access doors are available for use where insulation is being applied to the outside of the fan. Inlet Bell Quick-Open Access Door Bolted Access Door Raised Bolted Access Door On installations with an open inlet (no ductwork at the inlet of the fan), a streamlining inlet bell is required to achieve the catalogue performance. Outlet Dampers Due to the performance characteristics of industrial fans, a damper on the outlet of the fan is a very efficient way to control volume. Outlet Dampers Inlet Bell An outlet damper can be used to reduce the power consumption of a fan operating at high temperatures or a fan operating in low density gas streams. During a cold startup, the outlet damper begins in a closed position and is opened gradually as the fan reaches operating temperature. This allows for the use of a smaller motor sufficient to handle the duty at higher temperatures. Twin City Fan & Blower offers two basic styles of outlet dampers: Type 1 is made of single surface blades suitable for clean air applications, pressures to 620 Pa and temperatures to 148°C; Type 2 has double surface airfoil blades for abrasive type applications, pressures to 995 Pa and temperatures to 426°C. Both types of dampers are available with opposed or parallel blades and can be manually operated or set up for automatic operation. Inlet Vanes For reduced flow situations with relatively clean air, inlet vane type dampers are available to maintain fan efficiency. The inlet vanes are external type attached to the inlet of the fan. Standard construction inlet vanes are suitable in applications up to 148°C. High temperature inlet vanes are also available for temperatures up to 315°C. External Inlet Vanes ©2013 Twin City Fan Companies, Ltd., Minneapolis, MN. All rights reserved. Catalog illustrations cover the general appearance of Twin City Fan & Blower products at the time of publication and we reserve the right to make changes in design and construction at any time without notice. 6 Twin City Fan Catalogue M902 Accessories Inlet Boxes An inlet box is designed to minimize pressure drop and airflow losses. Inlet boxes are recommended for applications where uniform flow is difficult to obtain due to limited space or where the air must enter the fan at an angle. Inlet boxes can be either detachable or integral to the fan. This option is available with an inlet box damper to provide increased airflow control. Drains A pipe coupling can be welded to the lowest point in the housing scroll to allow wash water or condensation to drain. Inlet Box Drain Shaft Coolers Where high temperatures are encountered, the aluminum shaft cooler is recommended for dissipating heat and protecting bearings from the high temperature atmosphere. Shaft Seals The standard shaft seal is a non-asbestos type, sandwiched between two plates and the fan housing, providing a seal for most materials being handled. A variety of special seals, including mechanical type stuffing boxes, is available for gas-tight applications requiring more positive protection. Shaft Seal & Saft Cooler Spark Resistant Construction Three fan constructions are available for spark resistance. The materials used in the construction of these fans minimize the potential of sparks being generated by striking or rubbing components within the airstream. Type A –All parts of the fan in contact with the air or gas being handled are made of nonferrous material. (Aluminum impeller construction is limited to 120°C.) Type B –The fan has an entirely nonferrous impeller and nonferrous ring around the opening through which the shaft passes. (Aluminum impeller construction is limited to 120°C.) Type C –The fan is constructed so that a shift of the impeller or shaft will not permit two ferrous parts of the fan to rub or strike. In applications where aluminum is not suitable, impellers constructed of Monel can be furnished for temperatures up to 538°C. Other Accessories A large number of other appurtenances and accessories is available from Twin City Fan & Blower, including: • Belt guards – standard and OSHA type • Split housings • Shaft and bearing guards • Couplings and coupling guards • Impeller liners • Scroll liners • Weather covers • Inlet and outlet screen • Special material construction (stainless steel, Monel, etc.) • Special coatings and finishes • Insulation pins • Abrasion resistant construction • Common bases with and without isolation • Breaker tabs are offered on Series 900 RBP fans as an option on the relieved inlet transition. These tabs assist in the breakup of material as it enters the fan. Notes:1.The user must electrically ground the fan. 2.Standard spark resistant alloy is aluminum. 3.Bearings must not be placed in the air or gas stream. www.tcf.com 7 EngineeringData High Temperature Construction Requirements TEMPERATURE (°C) TYPE OF BEARING LUBRICATION OTHER REQUIREMENTS AVAILABLE ARRANGEMENTS –29° to 149° Ball or Roller Grease Standard Fan Arr. 1, 4, 8, 9 & 10; Arr. 4 limited to 82°C 149° to 260° Ball or Roller High Temp. Grease Shaft Cooler, Shaft Seal Expansion & Non-Expansion Bearings Arr. 1, 8, 9 and 10* 260° to 427° Ball or Roller High Temp. Grease High Temp. Aluminum Paint, Shaft Cooler, Shaft Seal, Expansion and Non-Expansion Bearings Arr. 1, 8, 9 & 10*; (Arr. 9 & 10 limited to 316°C unless fan is insulated.) 427° to 538° Ball or Roller High Temp. Grease Consult Factory *Arrangement 10 includes insulated pedestal Derating Factors for High Temperature TEMP. (ºC) 21 93 149 204 260 316 371 427 482 538 DERATING FACTOR RBO (22, 32); RBA (22); RBA (32); RBP (32) RBW (22, 32) STD STEEL STAINLESS 50 KSI STAINLESS 1.000 0.970 1.000 0.786 0.990 0.890 0.990 0.747 0.975 0.840 0.975 0.720 0.955 0.810 0.957 0.690 0.930 0.770 0.931 0.661 0.900 0.760 0.904 0.636 0.800 0.740 0.880 0.611 0.600 0.720 0.837 0.593 — 0.710 — 0.576 — 0.680 — 0.550 When elevated temperatures are encountered, maximum RPM allowable as shown below must be derated according to the values given in the table. Standard steel construction is suitable for use in gas temperatures up to 426°C. Aluminum impellers are suitable for temperatures up to 120°C only. For higher maximum RPM or elevated temperatures consult factory. Maximum RPM, Impeller Weights, & WR2 (Moment of Inertia) FAN SIZE 905 907 909 911 913 915 917 919 921 923 926 929 933 937 941 945 949 954 960 8 MODEL RBW MODEL RBA MODEL RBO/RBR MAX. IMPELLER WR2 MAX. IMPELLER WR2 MAX. IMPELLER WR2 (kg-m2) RPM WT. (kg) (kg-m2) RPM WT. (kg) (kg-m2) RPM WT. (kg) CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 3.6 — 0.02 — 5500 — — — — — — — — — — — — — 6.0 — 0.06 — 5296 — 8.2 — 0.10 — 5457 — 6.4 — 0.08 — 5273 — 7.5 — 0.10 — 4156 — 13.6 — 0.26 — 4192 — 11.8 — 0.29 — 4134 — 19.9 20 0.37 0.37 3283 3844 29.0 31.3 0.88 0.92 3495 4016 20.9 22.7 0.71 0.71 3373 4000 23.4 23 0.58 0.58 2822 3378 39.5 42.2 1.64 1.76 2922 3373 30.8 31.8 1.43 1.43 2812 3337 37.0 48 1.35 1.61 2485 2923 61.2 66.2 3.40 3.70 2531 2921 47.2 48.5 2.94 2.98 2521 2910 56.7 57 2.63 2.64 2191 2577 78.5 85.3 5.59 6.05 2232 2576 49.9 69.9 4.03 5.5 2147 2566 70.3 75 4.03 4.17 1951 2315 103 111 9.07 9.79 2004 2313 75.3 87 7.48 8.48 1928 2304 91.6 92 7.01 7.01 1778 2092 138 150 14.9 16.2 1791 2091 102 115 12.2 13.7 1733 2083 101 116 9.03 9.74 1623 1910 170 184 22.1 23.9 1635 1912 122 153 17.6 22.3 1581 1905 121 194 19.4 31.1 1439 1693 209 227 34.5 37.5 1449 1696 155 197 28.6 36.8 1402 1689 151 250 30.2 50.2 1286 1513 266 289 54.9 59.7 1295 1515 220 246 50.4 57.4 1253 1509 231 356 60.2 92.7 1129 1329 454 493 122 132 1137 1330 323 385 95.8 115 1100 1325 281 446 91.8 146 1009 1187 568 618 191 208 1015 1188 436 481 162 181 983 1184 361 551 144 220 911 1072 701 757 288 313 917 1024 534 598 243 275 888 1070 550 778 265 375 837 976 836 911 415 452 835 978 816 742 458 410 809 974 643 929 368 531 757 896 1014 1103 597 650 767 900 959 994 627 654 743 894 1249 — 865 — 692 — 1218 — 868 — 696 — 1170 — 924 — 674 1522 — 1303 — 622 — 1534 — 1351 — 627 — 1570 — 1530 — 607 Twin City Fan Catalogue M902 EngineeringData Bare Fan Weights (lb) ARRANGEMENTS FAN SIZE CLASS 22 1 45 60 79 151 191 278 339 428 738 887 1114 1353 1558 1965 2496 3065 4051 5368 6545 905 907 909 911 913 915 917 919 921 923 926 929 933 937 941 945 949 954 960 4 — 57 75 143 181 264 322 406 701 — — — — — — — — — — 8 59 78 103 196 248 361 440 556 959 1153 1448 1759 2026 2555 3245 3985 5267 — — 9 — — — — — — — — — — — — 1593 2013 2640 3215 4369 5746 6974 CLASS 32 9A, 9B 49 83 111 192 239 323 390 493 792 947 1183 1425 — — — — — — — 9F — 83 111 192 239 323 390 493 792 947 1183 1425 1593 2013 2640 3215 4369 5746 6974 10 49 83 111 192 239 323 390 493 792 947 1183 1425 — — — — — — — 1 — — — 172 227 325 397 501 788 1031 1258 1634 1876 2367 2871 3527 4164 — — 4 — — — 163 216 308 377 476 748 — — — — — — — — — — 8 — — — 224 295 422 517 651 1024 1340 1635 2124 2439 3078 3733 4585 5413 — — 9, 9F — — — 223 298 381 460 596 887 1168 1396 1797 1986 2490 3045 3704 4355 — — NOTE: Weights are less motor, drives and accessories Material Specifications HOUSING CLASS 22 FAN SIZE Sides 905 907 909 911 913 915 917 919 921 923 926 929 933 937 941 945 949 954 960 2.5 2.5 2.5 3 3 3 3 3 3 5 5 5 5 6 6 6 6 8 8 HOUSING CLASS 32 RBO/RBR IMPELLER (NOTE 2) RBW IMPELLER (NOTE 2) RBA IMPELLER (NOTE 2) Side Side CL 22 CL 32 Back CL 22 CL 32 Back Impeller CL 22 CL 32 Scroll Sides Scroll R Rim R Rim Plates Plates Blade Blade Plate Blade Blade Plate Cone Blade Blade 3 2.5 — — — 3 — — — — — — — — — — 3 2.5 — — — 3 — — — 6 5 — 5 3 2.5 — 3 2.5 — — — 3 — — — 6 5 — 5 3 3 — 3 3 5 5 5 5 — 5 — 6 6 6 6 3 5 5 3 3 5 5 5 5 — 6 — 6 6 6 6 5 5 5 3 3 5 5 5 6 — 6 — 8 8 8 8 5 5 5 3 3 5 5 5 6 — 6 — 8 8 8 8 5 5 6 3 3 5 5 5 8 — 8 — 8 8 8 8 5 5 6 5 3 5 5 5 8 — 8 — 10 10 10 10 5 5 6 5 5 6 6 5 8 — 8 — 10 10 10 10 5 5 8 5 5 6 6 6 8 — 8 6 10 10 10 10 5 5 8 5 5 6 6 6 8 — 8 6 10 10 10 10 5 6 8 6 5 6 6 6 10 — 10 6 12 12 12 12 5 6 8 6 5 6 6 6 10 — 10 6 12 12 12 12 5 8 10 6 5 6 6 6 10 — 10 6 12 12 12 12 5 8 10 10 6 5 6 6 6 12 — 12 6 12 12 — 16 6 10 6 6 6 6 6 12 — 12 6 12 12 — 16 6 10 10 8 8 — — — 20 — — — 12 12 — 16 6 10 — 8 8 — — — 20 — — — 12 12 — 20 6 10 — SHAFT DIAMTR CL 22 25 35 35 40 40 55 55 55 60 60 75 90 90 90 100 100 115 140 150 CL 32 — — — 50 50 60 60 75 75 90 90 100 100 125 125 125 140 — — BRG. CODE (NOTE 1) CL CL 22 32 HDB — HDB — HDB — HDB RB HDB RB HDB RB HDB RB RB RB RB RB RB RB RB RB RB RB RB RB RB SRB SRB SRB SRB SRB SRB SRB SRB — SRB — Dimensions are in mm unless otherwise noted. NOTES: 1. BEARINGS CODES: SDB — Standard-Duty Ball such as Dodge SCAH HDB — Heavy-Duty Ball such as Dodge SCMAH or Sealmaster MP Series RB — Roller Bearing such as Dodge S2000 or SKF SYR Series SRB — Split Roller Ball such as SKF SAF225 or Linkbelt PLB6800 Series 2. Gauges listed are for standard steel impeller; steel alloy will vary with size and class. 3. Bearing selection is made on the basis of L-10 bearing life to be in no case less than 40,000 hours minimum or L-50 life of 200,000 hours. www.tcf.com 9 InletBoxes Typical Inlet Box Dimensions A B F E D C C FAN SIZE A B 907 909 911 913 915 917 919 921 923 926 929 933 937 941 945 949 954 960 324 416 505 597 686 772 867 959 1051 1181 1321 1499 1689 1867 2048 2226 2457 2727 105 137 165 197 222 251 283 311 340 384 429 486 546 607 673 730 806 895 CL 22 CL 32 41 41 54 54 67 67 67 80 81 81 81 106 108 133 159 159 160 160 — — 56 56 68 68 68 81 83 83 83 108 108 133 159 159 — — D E INLET AREA (M2) 203 229 254 279 305 330 356 381 406 445 483 533 584 635 686 737 813 889 305 330 356 381 406 432 457 483 508 546 584 635 686 737 787 838 914 991 0.03 0.06 0.08 0.12 0.15 0.19 0.25 0.3 0.36 0.45 0.57 0.73 0.92 1.13 1.38 1.63 1.98 2.44 Dimensions are in millimeters unless otherwise noted. 10 Twin City Fan Catalogue M902 F 38 38 38 38 38 38 51 51 51 64 64 64 64 64 64 89 89 89 x x x x x x x x x x x x x x x x x x 38 38 38 38 38 38 51 51 51 64 64 64 64 64 64 89 89 89 7 3500 RPM 5 85 Lw 1,000 A 2850 RPM 800 0.55kW A 2000 RPM 400 0.18kW A PF - Fan Total Pressure (Pa) A Lw 0.25kW Lw 65 A Lw 1 Eff . 1450 RPM % 200 .E ff. 39 . % Pk 0.7 43 % Eff 48 PF - Fan Total Pressure (in W.G.) Lw 0.37kW 600 70 1.5 2500 RPM 75 2 80 3 PerformanceCurves RBO/R 905 2,000 0.5 100 0.02 0.04 0.06 0.08 0.1 0.2 qv - Flow (m³ / sec) 2 3 5 7 10 20 30 50 70 100 200 Pd - Fan Velocity Pressure (Pa) 50 70 100 200 300 500 qv - Flow (CFM) Fan Efficiency Grade = FEG 63 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 11 PerformanceCurves RBO/R 907 3500 RPM 10 95 2,000 Lw A 2850 RPM 7 2.2kW 90 2500 RPM Lw A 5 1.5kW 0.75kW 80 Lw A 600 0.55kW 1450 RPM 0.37kW A PF - Fan Total Pressure (Pa) 800 400 0.25kW 70 A Lw PF - Fan Total Pressure (in W.G.) A 1.1kW Lw 1.5 2000 RPM 75 2 Lw 3 85 1,000 0.18kW 65 1 A Lw 960 RPM Eff . 200 51 % 56 Eff . % Pk .E 50 ff. % 0.7 0.5 100 0.04 0.06 1 2 70 100 3 5 0.08 0.1 7 10 0.2 0.4 qv - Flow (m³ / sec) 20 30 50 70 Pd - Fan Velocity Pressure (Pa) 200 300 qv - Flow (CFM) 500 0.6 100 200 700 1000 300 0.8 500 1500 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 12 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 PerformanceCurves RBO/R 909 20 3500 RPM Lw A 15 5 10 4,000 0 10 2850 RPM Lw A 10 Lw A 7 4kW 85 Lw A 800 1.5kW 1450 RPM 1.1kW 80 Lw 600 A 0.75kW A PF - Fan Total Pressure (Pa) A 2.2kW 1,000 Lw 1.5 3kW Lw 5 75 PF - Fan Total Pressure (in W.G.) 90 2000 RPM 2 5.5kW 95 2,000 3 7.5kW 2500 RPM 0.55kW 400 70 0.37kW A Lw 960 RPM 0.25kW 65 1 A Lw 200 % Eff . Pk 51 % .E ff. Eff . 0.7 0.18kW 720 RPM 52 % 56 0.5 100 0.06 1 0.08 2 0.1 3 0.2 0.2 0.4 qv - Flow (m³ / sec) 5 7 0.3 10 20 30 0.6 50 70 100 Pd - Fan Velocity Pressure (Pa) 0.5 0.7 1 qv - Flow (CFM) (in Thousands) 0.8 1 200 300 1.5 2 2 500 700 1000 3 Fan Efficiency Grade = FEG 63 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 13 PerformanceCurves RBO/R 911 3500 RPM 0 11 6,000 Lw A 20 2850 RPM 22kW Lw 15 5 10 4,000 18.5kW A 2500 RPM 15kW 0 10 Lw 10 A 95 2,000 A 1,000 3kW Lw A 800 2.2kW 1.5kW Lw A 600 960 RPM 1.1kW A Lw PF - Fan Total Pressure (Pa) Lw 4kW 80 PF - Fan Total Pressure (in W.G.) A 90 1450 RPM 75 2 5.5kW 85 3 7.5kW Lw 7 5 11kW 2000 RPM 1.5 400 0.75kW 70 A Lw 0.55kW 720 RPM . 1 Eff 0.25kW 52 0.7 % 57 % 200 . Pk 51 .E % ff. Eff 0.37kW 0.18kW 0.5 100 0.1 0.2 2 3 5 0.3 7 0.4 0.6 0.8 qv - Flow (m³ / sec) 10 0.5 20 30 50 70 100 1 2 200 300 Pd - Fan Velocity Pressure (Pa) 0.7 1 1.5 2 qv - Flow (CFM) (in Thousands) 3 4 500 700 1000 5 2000 7 Fan Efficiency Grade = FEG 60 Notes: 1. 2. 3. 4. 5. 6. 7. 14 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 3350 RPM Lw 30 5 11 8,000 A 2850 RPM 6,000 0 11 55kW Lw 20 37kW 5 10 4,000 30kW Lw 15 45kW A 2500 RPM A Lw A Lw A 85 1,000 A Lw 4kW 800 960 RPM 3kW A Lw PF - Fan Total Pressure (Pa) 95 90 5.5kW 2.2kW 600 A 1.5kW 400 720 RPM 1.1kW 70 A Lw 1.5 7.5kW Lw 2 1450 RPM 80 3 11kW 75 PF - Fan Total Pressure (in W.G.) A 15kW 2,000 5 18.5kW Lw 10 7 22kW 0 10 2000 RPM PerformanceCurves RBO/R 913 10,000 0.75kW 65 0.55kW A Lw 1 0.37kW 60 500 RPM 100 0.1 . 0.2 1 2 3 0.3 0.4 5 0.5 7 0.25kW 0.18kW 57 0.5 % 63 % 58 Pk . % Eff . Eff . A Lw 0.7 Eff 200 10 0.6 0.8 1 2 qv - Flow (m³ / sec) 20 30 50 70 100 200 300 Pd - Fan Velocity Pressure (Pa) 0.7 1 1.5 2 3 qv - Flow (CFM) (in Thousands) 4 6 500 7001000 2000 5 10 7 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 15 2900 RPM 30 5 11 8,000 Lw 2500 RPM 6,000 A PerformanceCurves RBO/R 915 10,000 0 11 Lw 20 A Lw 15 55kW 45kW 5 10 2000 RPM 4,000 A 37kW 0 10 30kW Lw A A A 800 4kW 3kW A PF - Fan Total Pressure (Pa) Lw 5.5kW Lw 960 RPM 600 720 RPM 2.2kW 75 A Lw PF - Fan Total Pressure (in W.G.) 95 Lw 85 1,000 1.5kW 400 70 Lw 1.5 7.5kW Lw 2 11kW 80 3 15kW 90 5 18.5kW 1450 RPM 2,000 7 A 1.1kW 65 500 RPM A 0.25kW .E ff. Eff . 0.18kW . 0.37kW 57 % 63 0.7 0.55kW Eff % 58 Pk % 200 0.75kW Lw 1 22kW A 10 0.5 100 0.2 0.4 2 3 0.5 5 0.7 7 0.6 10 1 0.8 1 qv - Flow (m³ / sec) 20 30 50 70 100 2 4 200 300 Pd - Fan Velocity Pressure (Pa) 1.5 2 3 5 qv - Flow (CFM) (in Thousands) 6 500 700 1000 7 2000 10 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 16 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 2550 RPM 30 5 11 8,000 Lw A 6,000 90kW 0 11 Lw 2000 RPM 75kW A 20 55kW 5 10 4,000 Lw 15 A 37kW Lw A 15kW Lw A 11kW 960 RPM 85 1,000 7.5kW A Lw PF - Fan Total Pressure (Pa) A 95 18.5kW 5.5kW 800 Lw 3 22kW 2,000 90 5 30kW Lw 10 80 PF - Fan Total Pressure (in W.G.) 0 10 1450 RPM 7 45kW PerformanceCurves RBO/R 917 10,000 4kW A 720 RPM 600 3kW 75 A Lw 2 2.2kW 400 70 Lw 1.5kW A 500 RPM Eff 0.55kW % . Pk . % 58 1 1.1kW . Eff . 0.37kW % 63 Eff 1.5 0.75kW 57 200 0.4 3 0.7 0.6 5 7 1 0.8 10 1 20 2 4 qv - Flow (m³ / sec) 30 50 70 100 200 300 Pd - Fan Velocity Pressure (Pa) 1.5 2 3 5 7 qv - Flow (CFM) (in Thousands) 6 8 500 700 1000 10 10 2000 15 20 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 17 2300 RPM Lw 30 5 11 8,000 A PerformanceCurves RBO/R 919 10,000 2000 RPM 6,000 110kW 0 11 Lw 20 A 75kW 5 10 4,000 Lw 15 A 1450 RPM 55kW Lw A 30kW 2,000 Lw A 22kW 18.5kW 960 RPM 90 15kW A Lw 5 37kW 95 7 0 10 10 PF - Fan Total Pressure (Pa) 45kW 11kW 1,000 85 A Lw PF - Fan Total Pressure (in W.G.) 90kW 800 80 3 7.5kW 720 RPM A Lw 5.5kW 600 4kW 75 3kW A 500 RPM 400 .E ff. Eff . 2.2kW 0.75kW 0.003 0.005 1 0.01 1.5 Eff . 0.8 1 % 0.6 57 0.4 63 % Pk 58 % 1.5 Lw 2 1.1kW 2 1.5kW 4 6 qv - Flow (m³ / sec) 0.02 0.03 0.05 0.1 0.2 0.3 0.5 8 10 1 2 Pd - Fan Velocity Pressure (Pa) (in Thousands) 2 3 5 7 10 qv - Flow (CFM) (in Thousands) 15 20 20 3 5 30 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 18 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 0 12 2050 RPM Lw A 5 11 8,000 Lw 30 PerformanceCurves RBO/R 921 10,000 A 6,000 0 11 132kW Lw 20 110kW A 75kW 5 10 Lw 15 90kW 1450 RPM 4,000 A A Lw A 11kW 85 A Lw 720 RPM 1,000 7.5kW 800 5.5kW A 600 4kW Lw PF - Fan Total Pressure (Pa) A 90 15kW Lw 500 RPM A PF - Fan Total Pressure (in W.G.) Lw Lw 22kW 18.5kW 3kW 70 400 A Lw 1.5 960 RPM 75 2 30kW 80 3 2.2kW 65 A Lw 1.5kW 1 1.1kW 60 200 300 RPM A Lw . . 0.75kW 0.25kW 100 0.4 0.6 . Eff 0.8 0.0020.003 0.005 1 1.5 0.55kW 61 68 0.5 0.37kW % % 65 Pk . % Eff Eff 0.7 37kW 95 2,000 5 45kW 0 10 10 7 55kW 1 0.01 2 4 6 qv - Flow (m³ / sec) 0.02 0.03 0.05 0.1 0.2 0.3 8 0.5 Pd - Fan Velocity Pressure (Pa) (in Thousands) 2 3 5 7 10 qv - Flow (CFM) (in Thousands) 15 10 1 20 20 2 3 30 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 19 1900 RPM A 5 11 Lw 30 Lw 8,000 0 12 PerformanceCurves RBO/R 923 10,000 A 6,000 160kW 0 11 132kW Lw 1450 RPM A 20 90kW 5 10 4,000 15 110kW Lw 75kW A 0 10 55kW Lw 800 11kW 7.5kW A Lw 500 RPM 600 5.5kW A PF - Fan Total Pressure (Pa) A A A Lw 1,000 Lw PF - Fan Total Pressure (in W.G.) Lw Lw 85 15kW 4kW 70 400 3kW A Lw 1.5 720 RPM 75 2 22kW 18.5kW 80 3 30kW 90 5 37kW 95 960 RPM 2,000 7 45kW A 10 2.2kW 65 A Lw 1.5kW 1 60 300 RPM 200 Lw . . Eff 0.55kW 0.75kW 61 68 % % 65 Pk % .E Eff ff. A 0.7 1.1kW 0.37kW 0.5 100 0.6 0.8 1 2 0.003 0.0050.0070.01 4 qv - Flow (m³ / sec) 0.02 0.03 0.050.07 0.1 0.2 6 0.3 8 10 0.5 0.7 Pd - Fan Velocity Pressure (Pa) (in Thousands) 1.5 2 3 5 7 10 qv - Flow (CFM) (in Thousands) 15 20 20 1 2 3 30 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. 20 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 Lw A 30 0 12 1650 RPM 8,000 5 11 Lw 1450 RPM A 6,000 20 160kW 0 11 132kW Lw A 4,000 110kW 5 10 15 Lw 90kW A 75kW 0 10 A 720 RPM 30kW Lw A 22kW 18.5kW 1,000 15kW A Lw PF - Fan Total Pressure (Pa) A Lw 37kW 85 800 11kW 500 RPM A Lw 3 45kW 2,000 90 5 55kW 95 7 Lw 10 80 PF - Fan Total Pressure (in W.G.) 960 RPM PerformanceCurves RBO/R 926 10,000 7.5kW 75 600 Lw 400 4kW 70 A Lw 1.5 5.5kW A 2 3kW 65 2.2kW A Lw 300 RPM 2 1.5 0.8 1 3 5 2 7 10 3 Eff . 2 20 % 200 0.6 68 % 64 Pk % .E ff. Eff . 1 0.75kW 1.1kW 1.5kW 4 61 0.55kW qv - Flow (m³ / sec) 30 50 70 100 6 8 200 300 Pd - Fan Velocity Pressure (Pa) 5 7 10 15 qv - Flow (CFM) (in Thousands) 10 20 500 700 1000 20 2000 30 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 21 PerformanceCurves RBO/R 929 10,000 0 12 1500 RPM A 30 Lw 8,000 5 11 Lw 6,000 A 0 11 20 Lw A 160kW 4,000 132kW 5 10 15 Lw 960 RPM A 110kW Lw A 45kW 37kW A Lw 30kW 22kW 85 1,000 18.5kW Lw 500 RPM A PF - Fan Total Pressure (Pa) A 55kW 15kW 800 Lw 3 720 RPM 90 5 2,000 95 7 Lw 10 80 PF - Fan Total Pressure (in W.G.) 0 10 90kW 75kW A 11kW 75 600 7.5kW Lw A 2 5.5kW 70 A Lw 4kW 300 RPM 1.1kW 1.5kW 200 1 . % 68 1 7 10 3 2.2kW 61 2 5 3kW Eff % 65 Pk . % Eff . Eff . 1.5 400 4 6 8 qv - Flow (m³ / sec) 20 5 30 50 70 100 10 200 300 Pd - Fan Velocity Pressure (Pa) 7 10 15 20 qv - Flow (CFM) (in Thousands) 20 500 700 1000 30 2000 50 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. 22 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 Lw A 30 0 12 1300 RPM 8,000 5 11 Lw 6,000 A 0 11 20 Lw 960 RPM A 5 10 4,000 160kW Lw 15 A 132kW Lw A A A 85 Lw 1,000 A 22kW 800 18.5kW Lw A 15kW 600 11kW A PF - Fan Total Pressure (Pa) Lw Lw 30kW 7.5kW 300 RPM 400 70 5.5kW A Lw 1.5 500 RPM Lw 2 45kW 37kW 80 3 55kW 90 5 95 2,000 7 90kW 75kW 75 PF - Fan Total Pressure (in W.G.) 0 10 720 RPM 10 110kW PerformanceCurves RBO/R 933 10,000 65 4kW Lw 3kW A 1 200RPM 200 2.2kW .E ff. Eff 1 2 2 3 5 3 7 1.5kW 61 68 100 1.1kW % % Eff . Pk % 64 0.5 0.75kW A Lw . 60 0.7 0.55kW 4 6 8 qv - Flow (m³ / sec) 10 5 20 30 50 70 100 10 20 200 300 500 700 1000 Pd - Fan Velocity Pressure (Pa) 7 10 15 20 qv - Flow (CFM) (in Thousands) 30 50 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 23 0 12 1150 RPM Lw 8,000 A 30 5 11 6,000 Lw 960 RPM A PerformanceCurves RBO/R 937 10,000 0 11 Lw 20 A 5 10 4,000 Lw 15 A 720 RPM 160kW 0 10 A A 30kW 22kW 80 800 Lw A 18.5kW 15kW 600 300 RPM 11kW A PF - Fan Total Pressure (Pa) A Lw Lw 1,000 Lw PF - Fan Total Pressure (in W.G.) A Lw 45kW 37kW 400 70 7.5kW A Lw 1.5 55kW 75 2 500 RPM 85 3 90kW 75kW 90 5 110kW 95 2,000 7 132kW Lw 10 5.5kW 65 Lw 4kW A 200 RPM 1.1kW 3kW . .E Eff 2.2kW 61 68 % % 0.7 1.5kW Pk 64 % 200 ff. Eff . 1 0.5 100 1 2 2 3 3 5 4 7 5 10 6 8 10 20 qv - Flow (m³ / sec) 20 30 50 70 100 200 300 Pd - Fan Velocity Pressure (Pa) 7 10 15 20 qv - Flow (CFM) (in Thousands) 30 500 700 1000 50 70 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. 24 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 0 12 1050 RPM Lw 8,000 A 30 PerformanceCurves RBO/R 941 10,000 5 11 960 RPM Lw A 6,000 0 11 Lw 20 A 4,000 720 RPM 5 10 Lw 15 A Lw Lw A 90kW 75kW A Lw 55kW 45kW 85 Lw 1,000 37kW A PF - Fan Total Pressure (Pa) A 110kW 30kW 800 A Lw 3 500 RPM 90 5 2,000 132kW 95 7 160kW 80 PF - Fan Total Pressure (in W.G.) 0 10 10 22kW 300 RPM 18.5kW 75 600 15kW A Lw 2 11kW 70 A Lw 1.5 400 7.5kW 200 RPM . 2 Eff . 4 5 5 7 10 7 4kW 61 200 3kW % 68 % 65 Pk . Eff . Eff % 1 5.5kW 2.2kW 6 20 10 8 10 20 qv - Flow (m³ / sec) 30 50 70 100 200 300 Pd - Fan Velocity Pressure (Pa) 15 20 30 qv - Flow (CFM) (in Thousands) 40 500 700 1000 50 70 2000 100 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 25 PerformanceCurves RBO/R 945 10,000 960 RPM Lw 30 5 11 8,000 A 0 11 6,000 Lw 20 A 720 RPM 5 10 4,000 Lw A 15 0 10 Lw A 500 RPM 160kW 95 A Lw A 45kW 37kW 300 RPM 800 30kW A Lw PF - Fan Total Pressure (Pa) Lw 85 1,000 22kW 600 18.5kW A 15kW 400 11kW 70 200 RPM A Lw 1.5 55kW Lw 2 90kW 75kW 80 3 110kW 90 5 A 7 132kW Lw 2,000 75 PF - Fan Total Pressure (in W.G.) 10 7.5kW 65 5.5kW A Lw 1 150 RPM 3kW 2.2kW 6 8 61 68 % Eff . % Pk . Eff Eff 65 % 0.7 4kW 1.5kW . . 200 0.5 100 1 2 0.8 4 2 3 4 5 10 20 qv - Flow (m³ / sec) 8 20 40 80 Pd - Fan Velocity Pressure (Pa) 7 10 15 20 30 qv - Flow (CFM) (in Thousands) 200 40 400 50 60 800 70 2000 100 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. 26 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 PerformanceCurves RBO/R 949 0 11 720 RPM Lw A 20 5 10 4,000 Lw A 15 0 10 Lw 500 RPM A 10 95 160kW Lw 2,000 A 132kW 7 Lw 5 85 Lw A 55kW 45kW 800 37kW A Lw 30kW 600 22kW A 18.5kW 200 RPM 400 15kW 70 Lw 11kW A 1.5 300 RPM Lw 2 1,000 80 3 PF - Fan Total Pressure (Pa) A 90kW 75kW 75 PF - Fan Total Pressure (in W.G.) 90 110kW 7.5kW 65 1 2.2kW .E 5.5kW 3kW . 61 % 67 0.7 4kW Eff % 64 Pk % 200 ff. Eff . A Lw 150 RPM 0.5 100 2 4 2 4 5 6 8 7 10 8 10 qv - Flow (m³ / sec) 20 40 80 20 40 200 Pd - Fan Velocity Pressure (Pa) 15 20 30 qv - Flow (CFM) (in Thousands) 50 400 70 60 800 100 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 27 PerformanceCurves RBO/R 954 4,000 15 500 RPM 0 10 Lw A 10 95 Lw A 2,000 160kW 7 132kW 90 Lw 90kW 300 RPM 85 75kW Lw A 1,000 55kW 800 45kW 80 A Lw 3 PF - Fan Total Pressure (Pa) 5 37kW 30kW 600 75 PF - Fan Total Pressure (in W.G.) A 110kW A Lw 200 RPM 2 22kW 18.5kW 400 15kW 70 A Lw 1.5 11kW 150 RPM Eff Pk . % 7.5kW 200 5.5kW 60 % 67 Eff . % 64 1 4kW . Eff . 3kW 2 4 2 5 6 4 7 8 10 8 10 20 qv - Flow (m³ / sec) 20 40 40 80 200 Pd - Fan Velocity Pressure (Pa) 15 20 30 qv - Flow (CFM) (in Thousands) 50 60 400 70 800 100 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. 28 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 PerformanceCurves RBO/R 960 20 5 10 500 RPM Lw 4,000 A 15 0 10 Lw A 10 95 Lw A 2,000 A 132kW 110kW 90kW 85 Lw A 1,000 75kW 800 55kW A PF - Fan Total Pressure (Pa) Lw 300 RPM Lw 3 90 5 160kW 80 PF - Fan Total Pressure (in W.G.) 7 45kW 200 RPM 37kW 600 75 30kW Lw A 2 22kW 18.5kW 70 150 RPM Lw 1.5 400 15kW 7.5kW . % 64 Pk . % Eff . Eff . A 5.5kW Eff 11kW % 67 60 1 200 4 6 3 5 8 7 10 10 10 15 20 40 qv - Flow (m³ / sec) 20 30 50 70 100 200 50 70 Pd - Fan Velocity Pressure (Pa) 20 30 qv - Flow (CFM) (in Thousands) 300 60 80 100 500 700 1000 100 150 200 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 29 PerformanceCurves RBA 907 3500 RPM 95 10 Lw A 2,000 90 Lw 2850 RPM 2.2kW A 7 1.5kW 85 2500 RPM Lw 5 A 1.1kW Lw A 0.55kW Lw A 600 0.37kW 1450 RPM 70 A Lw 1.5 0.75kW 75 2 PF - Fan Total Pressure (Pa) 80 3 2000 RPM 800 400 0.25kW 65 0.18kW A Lw PF - Fan Total Pressure (in W.G.) 1,000 60 1 A Lw Eff . 960 RPM 200 64 % 67 % Eff . Pk .E ff. 62 % 0.7 0.5 100 0.06 0.08 4 0.1 8 200 0.2 qv - Flow (m³ / sec) 20 40 80 0.4 Pd - Fan Velocity Pressure (Pa) 300 500 qv - Flow (CFM) 700 0.6 200 1000 0.8 400 1500 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. 30 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 PerformanceCurves RBA 909 20 3500 RPM 15 0 10 4,000 Lw A 2850 RPM 7.5kW 95 10 Lw 5.5kW A 2500 RPM 2,000 4kW 90 Lw 7 A 3kW A Lw 800 1.1kW A 1450 RPM 600 0.75kW A Lw 0.55kW 400 A PF - Fan Total Pressure (Pa) Lw 1.5kW Lw 1.5 1,000 75 2 2.2kW 80 3 85 5 70 PF - Fan Total Pressure (in W.G.) 2000 RPM 0.37kW 65 960 RPM Lw A 0.25kW 1 60 0.18kW A Lw Eff . 100 0.1 4 Eff 65 % 67 % 0.5 . Pk 63 .E ff. % 0.7 200 720 RPM 0.2 8 0.3 0.4 0.6 0.8 qv - Flow (m³ / sec) 20 0.5 40 80 0.7 1 1 200 400 Pd - Fan Velocity Pressure (Pa) 1.5 qv - Flow (CFM) (in Thousands) 2 2 800 3 Fan Efficiency Grade = FEG 75 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 31 PerformanceCurves RBA 911 3500 RPM 6,000 0 11 Lw 5 10 A Lw 20 18.5kW 0 10 15 A 2850 RPM 4,000 15kW Lw 2500 RPM A 11kW 95 10 Lw A 2000 RPM 2,000 7.5kW Lw A 2.2kW A Lw 800 600 1.5kW 1.1kW A Lw 960 RPM 0.75kW 400 A 0.55kW 65 0.37kW A Lw 720 RPM Eff % 0.18kW 65 68 0.7 0.25kW . Pk 200 .E 63 ff. % Eff . 1 % PF - Fan Total Pressure (Pa) A Lw 1,000 Lw 1.5 3kW 75 2 1450 RPM 80 3 85 5 4kW 70 PF - Fan Total Pressure (in W.G.) 5.5kW 90 7 0.5 100 0.1 0.2 2 4 0.3 0.4 0.6 0.8 qv - Flow (m³ / sec) 8 0.5 20 40 80 1 2 200 400 Pd - Fan Velocity Pressure (Pa) 0.7 1 1.5 2 qv - Flow (CFM) (in Thousands) 3 4 800 5 2000 7 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. 32 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 0 12 3300 RPM Lw 8,000 A 30 2850 RPM 5 11 6,000 Lw 20 A 2500 RPM 37kW 30kW 0 11 Lw 4,000 A 15 22kW 18.5kW 5 10 2000 RPM Lw Lw A 4kW 90 A Lw 1,000 3kW 800 Lw 2.2kW A 960 RPM 600 1.5kW A PF - Fan Total Pressure (Pa) A 95 5.5kW Lw PF - Fan Total Pressure (in W.G.) Lw 7.5kW 80 2 1450 RPM 85 3 11kW 0 10 2,000 5 15kW A 10 7 PerformanceCurves RBA 913 10,000 1.1kW 720 RPM 75 A Lw 1.5 400 0.75kW 70 Lw A 0.55kW 1 65 0.37kW Lw Eff % 100 0.2 0.4 4 0.5 8 0.7 0.18kW 70 74 0.5 % % Eff . Pk . 70 0.25kW . Eff . A 0.7 200 500 RPM 0.6 20 1 0.8 1 qv - Flow (m³ / sec) 40 80 200 2 4 400 800 5 7 Pd - Fan Velocity Pressure (Pa) 1.5 2 3 qv - Flow (CFM) (in Thousands) 6 2000 10 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 33 2850 RPM 8,000 Lw 30 0 12 PerformanceCurves RBA 915 10,000 A 2500 RPM 5 11 6,000 55kW Lw A 20 0 11 37kW Lw A 15 45kW 2000 RPM 4,000 30kW 5 10 22kW Lw A 18.5kW A Lw A 960 RPM 4kW 800 Lw A 3kW 600 720 RPM 2.2kW A PF - Fan Total Pressure (Pa) A Lw 90 5.5kW 1.5kW 75 400 Lw 1.1kW A 1.5 1,000 Lw 2 7.5kW 85 3 11kW 95 5 Lw 7 15kW 0 10 1450 RPM 2,000 80 PF - Fan Total Pressure (in W.G.) 10 70 Lw A 0.75kW 500 RPM 0.55kW . 0.37kW 70 74 % % 0.7 Eff Pk 70 200 0.25kW .E % ff. Eff . 1 0.5 100 0.4 0.6 8 0.7 0.8 20 1 1.5 1 2 4 qv - Flow (m³ / sec) 40 80 200 Pd - Fan Velocity Pressure (Pa) 2 3 5 qv - Flow (CFM) (in Thousands) 400 6 800 7 2000 10 Fan Efficiency Grade = FEG 75 Notes: 1. 2. 3. 4. 5. 6. 7. 34 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 0 12 2500 RPM 8,000 Lw 30 A 5 11 6,000 Lw 2000 RPM A 20 55kW 0 11 45kW A 15 Lw 4,000 37kW A Lw A Lw 11kW A 960 RPM 7.5kW Lw 1,000 A PF - Fan Total Pressure (Pa) 0 10 15kW 90 5.5kW 800 Lw 4kW A 3 2,000 95 5 22kW 18.5kW 85 PF - Fan Total Pressure (in W.G.) Lw 10 7 30kW 5 10 1450 RPM PerformanceCurves RBA 917 720 RPM 3kW 80 600 A Lw 2 2.2kW 75 400 Lw 1.5kW A 1.5 500 RPM 0.6 0.8 8 Eff . 1 20 1.5 0.55kW 70 74 200 0.75kW % % 1 Pk . 70 % Eff . Eff . 1.1kW 2 4 qv - Flow (m³ / sec) 40 80 200 6 400 800 Pd - Fan Velocity Pressure (Pa) 2 3 5 7 qv - Flow (CFM) (in Thousands) 8 10 2000 15 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 35 PerformanceCurves RBA 919 10,000 2300 RPM Lw 30 0 12 8,000 A 2000 RPM 5 11 6,000 90kW Lw A 20 75kW 0 11 4,000 55kW Lw A 15 1450 RPM 45kW Lw A 960 RPM 18.5kW 15kW A Lw 11kW Lw 1,000 7.5kW A PF - Fan Total Pressure (Pa) Lw 22kW 90 720 RPM 800 5.5kW A Lw 3 2,000 95 5 0 10 7 30kW A 10 85 PF - Fan Total Pressure (in W.G.) 5 10 37kW 4kW 80 600 Lw A 3kW 2 2.2kW 75 Lw 0.75kW 1.5kW 1.1kW 70 74 % % Eff . Pk 70 .E % ff. Eff . A 1.5 500400 RPM 1 200 0.8 1 0.02 1.5 2 2 0.04 4 qv - Flow (m³ / sec) 0.08 0.2 0.4 7 10 6 8 10 0.8 Pd - Fan Velocity Pressure (Pa) (in Thousands) 3 5 15 qv - Flow (CFM) (in Thousands) 20 2 20 4 30 Fan Efficiency Grade = FEG 75 Notes: 1. 2. 3. 4. 5. 6. 7. 36 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 2000 RPM 8,000 30 5 11 Lw 6,000 A 20 90kW 0 11 75kW Lw 1450 RPM A 4,000 15 PerformanceCurves RBA 921 10,000 55kW 5 10 Lw 45kW A 37kW Lw Lw A 11kW Lw A 720 RPM 1,000 7.5kW Lw A 800 5.5kW 600 4kW A PF - Fan Total Pressure (Pa) 95 15kW Lw 500 RPM 3kW 75 2 22kW 18.5kW 85 3 960 RPM 90 5 A 2,000 7 30kW 80 A Lw PF - Fan Total Pressure (in W.G.) 0 10 10 400 2.2kW 70 A Lw 1.5 1.5kW 65 A 200 300 RPM 0.75kW 60 A Lw 0.55kW 100 0.6 0.8 . 1 0.008 1.5 0.37kW 72 76 % % 0.5 Eff Pk . Eff . 0.7 1.1kW Lw 1 2 0.02 0.04 4 qv - Flow (m³ / sec) 0.08 0.2 6 8 0.4 10 0.8 Pd - Fan Velocity Pressure (Pa) (in Thousands) 2 3 5 7 10 15 qv - Flow (CFM) (in Thousands) 20 20 2 4 30 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 37 PerformanceCurves RBA 923 10,000 1900 RPM 8,000 30 5 11 Lw 6,000 A 132kW 1450 RPM 20 110kW 0 11 Lw A 4,000 15 90kW 75kW 5 10 Lw 55kW A 45kW A 95 Lw A 720 RPM Lw A 11kW 1,000 Lw 7.5kW A 800 80 5.5kW Lw A 500 RPM 600 4kW A 3kW 400 70 1.5 18.5kW 15kW Lw 2 22kW 85 3 30kW 90 5 PF - Fan Total Pressure (Pa) 2,000 7 37kW Lw 960 RPM 75 PF - Fan Total Pressure (in W.G.) 0 10 10 A Lw 2.2kW 1.5kW 65 A Lw 1 1.1kW ff. 300 RPM 200 Eff . 0.75kW 76 72 % % Pk .E 0.7 0.55kW 0.5 100 0.8 1 2 0.008 2 0.02 4 qv - Flow (m³ / sec) 0.04 0.08 5 7 0.2 6 8 0.4 10 20 0.8 2 Pd - Fan Velocity Pressure (Pa) (in Thousands) 3 10 15 qv - Flow (CFM) (in Thousands) 20 30 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. 38 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 1650 RPM 8,000 30 5 11 1450 RPM Lw 6,000 A 160kW 20 132kW 0 11 110kW Lw A 4,000 15 90kW 5 10 Lw 55kW Lw A 37kW 30kW 95 Lw 720 RPM A 22kW 18.5kW A Lw 15kW 1,000 11kW A Lw PF - Fan Total Pressure (Pa) 0 2,000 800 500 RPM 7.5kW 80 3 45kW 90 5 10 10 85 A Lw 600 5.5kW 75 A Lw 2 4kW 400 3kW 70 A Lw 1.5 2.2kW 65 300 RPM 8 % 2 72 1 4 6 8 qv - Flow (m³ / sec) 20 3 1.5kW Eff . Eff . Pk . % 200 A Lw 1 76 PF - Fan Total Pressure (in W.G.) A 960 RPM 7 75kW PerformanceCurves RBA 926 10,000 40 80 200 Pd - Fan Velocity Pressure (Pa) 5 7 10 15 qv - Flow (CFM) (in Thousands) 10 400 20 20 800 2000 30 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 39 PerformanceCurves RBA 929 10,000 1500 RPM 8,000 30 5 11 Lw 6,000 A 20 0 11 160kW Lw 132kW A 4,000 15 960 RPM 110kW 5 10 Lw 90kW A Lw A Lw A 30kW 22kW A Lw 18.5kW 1,000 500 RPM 15kW A PF - Fan Total Pressure (Pa) 0 10 37kW Lw 3 45kW 90 5 720 RPM 2,000 95 7 55kW 85 PF - Fan Total Pressure (in W.G.) 75kW 10 800 11kW 80 A Lw 600 7.5kW 75 2 A Lw 5.5kW 400 4kW 70 Lw A 300 RPM 3kW 200 1 Eff . 2 4 8 3 2.2kW % 76 1 1.5kW 72 % Pk . Eff . 1.5 4 6 8 qv - Flow (m³ / sec) 20 5 40 80 10 200 400 Pd - Fan Velocity Pressure (Pa) 7 10 15 20 qv - Flow (CFM) (in Thousands) 20 800 30 2000 50 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. 40 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 1300 RPM 8,000 30 5 11 Lw 6,000 A 20 0 11 960 RPM Lw A 4,000 15 160kW 5 10 132kW Lw 110kW A 720 RPM 0 10 10 90kW A 95 Lw A Lw 30kW A 22kW 85 1,000 A Lw 18.5kW 800 15kW Lw A 11kW 600 7.5kW A 300 RPM 5.5kW 400 70 A Lw 1.5 500 RPM Lw 2 45kW 37kW 80 3 55kW 90 5 PF - Fan Total Pressure (Pa) 2,000 7 75 PF - Fan Total Pressure (in W.G.) Lw 75kW PerformanceCurves RBA 933 10,000 4kW 65 3kW Lw A 1 2.2kW 60 200 RPM 200 . 1 2 Eff . Eff % 2 4 3 1.1kW 72 Pk . % 76 100 1.5kW A 0.5 Lw 0.7 4 6 8 qv - Flow (m³ / sec) 8 20 40 80 10 200 Pd - Fan Velocity Pressure (Pa) 5 7 10 15 20 qv - Flow (CFM) (in Thousands) 20 400 30 800 50 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 41 1150 RPM 8,000 0 12 30 A Lw 960 RPM Lw 6,000 5 11 A PerformanceCurves RBA 937 10,000 0 11 20 Lw A 4,000 15 5 10 160kW Lw 720 RPM A 132kW 0 10 10 110kW Lw 90kW Lw A A 85 Lw A 22kW 800 18.5kW 15kW A Lw PF - Fan Total Pressure (Pa) 95 Lw 30kW 1,000 600 300 RPM 11kW A 7.5kW 400 70 5.5kW A Lw 1.5 37kW Lw 2 55kW 45kW 80 3 500 RPM 90 5 75kW 75 PF - Fan Total Pressure (in W.G.) A 2,000 7 4kW 65 Lw A 200 RPM 3kW 1.5kW 2.2kW 72 76 % % 0.7 Eff Pk 200 . .E ff. 1 0.5 100 2 4 8 5 6 20 7 8 10 20 qv - Flow (m³ / sec) 40 80 200 Pd - Fan Velocity Pressure (Pa) 10 15 20 30 qv - Flow (CFM) (in Thousands) 400 800 50 70 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. 42 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 1050 RPM 8,000 30 PerformanceCurves RBA 941 10,000 0 12 960 RPM Lw A 5 11 Lw 6,000 A 0 11 20 Lw A 720 RPM 4,000 15 5 10 Lw A 55kW Lw A 45kW 37kW 1,000 30kW A Lw PF - Fan Total Pressure (Pa) A Lw 75kW 85 PF - Fan Total Pressure (in W.G.) A Lw 90kW 500 RPM 800 22kW 300 RPM 80 3 2,000 90 5 110kW 95 7 132kW 0 10 10 160kW A Lw 18.5kW 600 15kW 75 A 400 7.5kW 70 A Lw 1.5 11kW Lw 2 200 RPM .E ff. 5.5kW 2.2kW 200 4 Eff . % 3kW 6 8 20 7 4kW 72 76 % Pk 1 10 8 40 10 qv - Flow (m³ / sec) 80 200 20 40 400 Pd - Fan Velocity Pressure (Pa) 15 20 30 qv - Flow (CFM) (in Thousands) 50 800 70 2000 100 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 43 PerformanceCurves RBA 945 10,000 960 RPM 8,000 30 5 11 Lw A 6,000 20 0 11 720 RPM Lw A 4,000 5 10 15 Lw A 0 10 A A 800 30kW Lw 22kW A PF - Fan Total Pressure (Pa) Lw A Lw 37kW 300 RPM 600 18.5kW 15kW A Lw PF - Fan Total Pressure (in W.G.) 95 Lw 85 1,000 11kW 400 200 RPM 70 Lw 1.5 55kW 45kW 75 2 90kW 75kW 80 3 110kW 90 5 132kW A 500 RPM 2,000 7 160kW Lw 10 A 7.5kW 5.5kW 65 A Lw 1 4kW 150 RPM 3kW Eff . 1.5kW 2.2kW % 76 % Pk .E ff. 0.7 72 200 0.5 100 2 4 3 5 5 7 7 6 10 20 8 10 qv - Flow (m³ / sec) 30 50 70 100 20 40 200 300 Pd - Fan Velocity Pressure (Pa) 10 15 20 30 qv - Flow (CFM) (in Thousands) 50 60 500 700 1000 70 2000 100 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. 44 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 PerformanceCurves RBA 949 720 RPM 0 11 20 Lw A 4,000 5 10 15 Lw A 0 10 500 RPM Lw 10 A 132kW 95 2,000 160kW Lw A 7 110kW Lw A 85 45kW Lw 300 RPM A 37kW 800 30kW A Lw 600 22kW 18.5kW A 15kW 200 RPM 400 11kW 70 A Lw 1.5 55kW 1,000 Lw 2 75kW 80 3 PF - Fan Total Pressure (Pa) 90 5 75 PF - Fan Total Pressure (in W.G.) 90kW 7.5kW 65 150 RPM Lw 5.5kW .E ff. A 1 Eff 72 % % 75 0.7 4kW . Pk 200 2.2kW 3kW 0.5 100 4 6 7 10 10 8 20 15 10 30 20 40 qv - Flow (m³ / sec) 50 70 100 200 300 Pd - Fan Velocity Pressure (Pa) 20 30 50 qv - Flow (CFM) (in Thousands) 500 70 60 700 1000 100 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 45 PerformanceCurves RBA 954 4,000 15 500 RPM 0 10 Lw 10 A 160kW 95 2,000 Lw 132kW A 7 Lw A Lw 1,000 A 55kW 45kW 800 37kW A Lw 30kW 600 22kW 75 200 RPM A Lw 2 18.5kW 15kW 400 70 A Lw 1.5 75kW 300 RPM 80 3 PF - Fan Total Pressure (Pa) 90 5 90kW 85 PF - Fan Total Pressure (in W.G.) 110kW 11kW .E ff. 150 RPM 7.5kW 4kW 5.5kW 71 % 75 Eff . % Pk 1 200 6 7 8 10 10 20 15 20 40 qv - Flow (m³ / sec) 30 50 70 100 200 Pd - Fan Velocity Pressure (Pa) 20 30 50 qv - Flow (CFM) (in Thousands) 300 70 500 60 700 100 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. 46 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 PerformanceCurves RBA 960 20 500 RPM 4,000 5 10 15 Lw A 0 10 Lw 10 A 2,000 95 Lw A 1,000 75kW 85 A Lw 55kW 800 45kW 200 RPM 37kW A PF - Fan Total Pressure (Pa) Lw 90kW Lw PF - Fan Total Pressure (in W.G.) 110kW 80 3 132kW 300 RPM 90 5 600 30kW 75 2 Lw 22kW A 18.5kW 400 15kW 70 150 RPM Lw 11kW 7.5kW 71 % 75 Eff . % Pk .E A ff. 1.5 160kW A 7 1 200 6 8 7 10 10 15 20 20 20 40 qv - Flow (m³ / sec) 30 50 70 100 200 50 70 Pd - Fan Velocity Pressure (Pa) 30 qv - Flow (CFM) (in Thousands) 60 300 500 100 700 80 1000 150 Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 47 PerformanceCurves RBW 905 2,000 7 3500 RPM 90 5 Lw A 1,000 85 2850 RPM Lw Lw A 0.25kW A Lw 2000 RPM 400 0.18kW A Lw 1450 RPM % Pk 54 .E % 200 ff. Eff . 1 600 75 1.5 0.37kW 80 2 PF - Fan Total Pressure (Pa) 2500 RPM 70 PF - Fan Total Pressure (in W.G.) A 800 3 51 % Eff . 59 0.7 0.5 100 0.02 0.04 2 3 50 5 70 0.06 0.08 0.1 20 30 0.2 qv - Flow (m³ / sec) 7 10 50 Pd - Fan Velocity Pressure (Pa) 100 200 qv - Flow (CFM) 70 300 100 200 500 Fan Efficiency Grade = FEG ?? Notes: 1. 2. 3. 4. 5. 6. 7. 48 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 3500 RPM 0 10 10 Lw A 2,000 95 2850 RPM Lw 7 A 2.2kW 2500 RPM 90 5 Lw A 1.5kW A A 0.55kW 1450 RPM 0.37kW A Lw PF - Fan Total Pressure (Pa) Lw Lw 600 75 1.5 0.75kW 80 2 1.1kW 85 3 2000 RPM 800 400 0.25kW 70 A Lw PF - Fan Total Pressure (in W.G.) 1,000 PerformanceCurves RBW 907 0.18kW 65 1 A Lw 960 RPM Eff . 59 % Pk 55 .E % 0.7 ff. Eff . 200 52 % 0.5 100 0.04 0.06 1 2 70 100 3 5 0.08 0.1 7 10 0.2 0.4 qv - Flow (m³ / sec) 20 30 50 70 Pd - Fan Velocity Pressure (Pa) 200 300 qv - Flow (CFM) 500 0.6 100 200 700 1000 300 0.8 500 1500 Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 49 PerformanceCurves RBW 909 20 3500 RPM 4,000 15 5 10 Lw A 2850 RPM 0 10 10 7.5kW Lw 2500 RPM A 2,000 5.5kW 95 7 Lw A 4kW A 1.5kW A 1450 RPM 600 1.1kW A Lw 0.75kW 400 A PF - Fan Total Pressure (Pa) Lw Lw 800 Lw 1.5 2.2kW 80 2 1,000 85 3 3kW 90 5 75 PF - Fan Total Pressure (in W.G.) 2000 RPM 70 960 RPM 0.55kW Lw A 0.37kW 0.25kW 65 1 A Lw 200 0.18kW 720 RPM 52 % 0.5 Eff . 59 % Pk 55 % .E ff. Eff . 0.7 100 0.06 1 0.08 2 0.1 3 0.2 0.2 0.4 qv - Flow (m³ / sec) 5 7 0.3 10 20 30 0.6 50 70 100 Pd - Fan Velocity Pressure (Pa) 0.5 0.7 1 qv - Flow (CFM) (in Thousands) 0.8 1 200 300 1.5 2 2 500 700 1000 3 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 50 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 30 5 11 3500 RPM Lw 6,000 A 0 11 20 Lw 2850 RPM A 4,000 15 PerformanceCurves RBW 911 8,000 22kW 5 10 2500 RPM Lw 18.5kW A 15kW 0 10 10 A A 1,000 3kW Lw 800 A 2.2kW 600 1.5kW A Lw PF - Fan Total Pressure (Pa) Lw Lw 4kW 80 2 1450 RPM 85 3 5.5kW 90 5 7.5kW 95 7 960 RPM 1.1kW 75 400 A 1.5 Lw PF - Fan Total Pressure (in W.G.) A 2,000 11kW Lw 2000 RPM 0.75kW 70 Lw A 0.55kW 720 RPM .E % Eff 0.18kW 0.25kW 53 % 0.7 . 60 % Pk 55 200 0.37kW ff. Eff . 1 0.5 100 0.1 0.2 2 3 5 0.3 7 0.4 0.6 0.8 qv - Flow (m³ / sec) 10 0.5 20 30 50 70 100 1 2 200 300 Pd - Fan Velocity Pressure (Pa) 0.7 1 1.5 2 qv - Flow (CFM) (in Thousands) 3 4 500 700 1000 5 2000 7 Fan Efficiency Grade = FEG 63 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 51 PerformanceCurves RBW 913 2850 RPM 5 11 6,000 Lw A 20 2500 RPM 0 11 4,000 30kW Lw 15 A 22kW 5 10 2000 RPM Lw A 10 Lw A Lw A 90 Lw 1,000 A 4kW 3kW 85 800 Lw A 960 RPM 600 2.2kW A PF - Fan Total Pressure (Pa) 95 5.5kW 1.5kW 75 400 720 RPM Lw 1.1kW A 1.5 7.5kW Lw 2 1450 RPM 11kW 80 PF - Fan Total Pressure (in W.G.) 7 3 15kW 0 10 2,000 5 18.5kW 70 0.75kW A Lw 1 0.55kW 65 A Lw 200 500 RPM 0.37kW 0.25kW % Eff . Pk . 59 % Eff . Eff . 0.7 0.18kW 57 % 63 0.5 100 0.1 0.2 1 2 3 0.3 0.4 5 0.5 7 10 0.6 0.8 1 2 qv - Flow (m³ / sec) 20 30 50 70 100 200 300 Pd - Fan Velocity Pressure (Pa) 0.7 1 1.5 2 3 qv - Flow (CFM) (in Thousands) 4 500 7001000 2000 5 10 7 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 52 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 0 12 2850 RPM 8,000 Lw 30 A 2500 RPM 6,000 5 11 Lw 20 A 0 11 45kW Lw A 15 55kW 2000 RPM 4,000 37kW 5 10 Lw 30kW A 22kW A Lw 5.5kW A 960 RPM 800 4kW A Lw 3kW 600 720 RPM A PF - Fan Total Pressure (Pa) A Lw 90 1,000 2.2kW 75 400 1.5kW A Lw 1.5 7.5kW Lw 2 11kW 85 3 15kW 95 5 Lw 2,000 7 18.5kW 0 10 1450 RPM 80 PF - Fan Total Pressure (in W.G.) 10 PerformanceCurves RBW 915 70 1.1kW A Lw 500 RPM 0.75kW 0.37kW 57 % 64 % Eff . Pk 59 0.7 0.55kW 0.25kW .E % 200 ff. Eff . 1 0.5 100 0.2 0.4 2 3 0.5 5 0.7 7 0.6 10 1 0.8 1 qv - Flow (m³ / sec) 20 30 50 70 100 2 4 200 300 Pd - Fan Velocity Pressure (Pa) 1.5 2 3 5 qv - Flow (CFM) (in Thousands) 6 500 700 1000 7 2000 10 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 53 PerformanceCurves RBW 917 2500 RPM 8,000 0 12 30 Lw A 6,000 5 11 Lw 2000 RPM A 20 75kW 0 11 Lw 4,000 55kW A 15 45kW 5 10 A 10 A 15kW Lw A 11kW 960 RPM 90 Lw 1,000 A PF - Fan Total Pressure (Pa) Lw 18.5kW 800 7.5kW 5.5kW A Lw 3 22kW 95 5 2,000 0 10 7 30kW 85 PF - Fan Total Pressure (in W.G.) 37kW Lw 1450 RPM 720 RPM 4kW 80 600 Lw A 3kW 2 2.2kW 75 A Lw 1.5kW % Pk . 59 1 1.1kW Eff Eff A Lw . 70 500 RPM . 1.5 400 0.75kW 57 200 % 64 Eff . % 0.55kW 0.4 3 0.7 0.6 5 7 1 0.8 10 1 20 30 2 4 qv - Flow (m³ / sec) 50 70 100 200 300 Pd - Fan Velocity Pressure (Pa) 1.5 2 3 5 7 qv - Flow (CFM) (in Thousands) 6 8 500 700 1000 10 10 2000 15 20 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 54 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 2000 RPM 5 11 6,000 Lw A 20 0 11 75kW Lw 4,000 A 15 1450 RPM 55kW 5 10 45kW Lw A A A 15kW 90 A Lw 11kW 1,000 7.5kW 720 RPM 800 A PF - Fan Total Pressure (Pa) Lw 18.5kW Lw 960 RPM Lw 3 22kW 95 5 30kW 0 10 2,000 7 37kW 85 PF - Fan Total Pressure (in W.G.) 10 PerformanceCurves RBW 919 5.5kW 80 600 A Lw 4kW 2 75 400500 RPM A Lw . 2.2kW ff. Eff 0.75kW 1.5kW 1.1kW % 63 Eff . % 59 Pk .E % 1.5 3kW 57 1 200 0.4 0.6 3 5 1 0.8 7 1 10 1.5 2 4 qv - Flow (m³ / sec) 20 30 50 70 100 200 5 7 Pd - Fan Velocity Pressure (Pa) 2 3 qv - Flow (CFM) (in Thousands) 6 300 8 10 500 700 1000 10 15 20 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 55 PerformanceCurves RBW 921 0 12 2000 RPM 8,000 Lw 30 A 5 11 Lw 6,000 A 20 Lw 90kW A 4,000 15 110kW 0 11 1450 RPM 75kW 5 10 Lw 55kW A 45kW A Lw A 720 RPM 1,000 11kW Lw A 800 7.5kW 600 5.5kW A Lw PF - Fan Total Pressure (Pa) A Lw 15kW 80 2 22kW 18.5kW 85 3 960 RPM 90 5 30kW 95 7 37kW Lw 2,000 500 RPM 4kW 75 1.5 A Lw PF - Fan Total Pressure (in W.G.) 0 10 10 400 3kW 70 A Lw 2.2kW 1.5kW 65 1 A Lw 1.1kW 60 0.75kW 0.25kW 0.37kW 0.55kW 60 % 67 % 0.5 Eff . 62 Pk . % Eff . Eff . A Lw 0.7 200 300 RPM 100 0.4 0.6 0.002 0.7 0.004 1 0.8 1 0.01 2 4 6 qv - Flow (m³ / sec) 0.02 0.04 0.1 0.2 8 0.4 Pd - Fan Velocity Pressure (Pa) (in Thousands) 1.5 2 3 5 7 10 qv - Flow (CFM) (in Thousands) 15 10 1 20 20 2 4 30 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 56 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 PerformanceCurves RBW 923 1450 RPM 20 0 11 Lw A 4,000 15 5 10 75kW Lw A 55kW 0 10 10 45kW Lw 960 RPM A 2,000 37kW 30kW 95 7 Lw A A 7.5kW A Lw 500 RPM 600 5.5kW 4kW A PF - Fan Total Pressure (Pa) Lw 11kW Lw 800 Lw 1.5 15kW 1,000 80 2 18.5kW 85 3 720 RPM 90 5 75 PF - Fan Total Pressure (in W.G.) A 22kW 400 3kW 70 A Lw 65 1 2.2kW Lw 1.5kW A . 1.1kW 0.37kW 0.55kW 0.75kW 59 % 66 % Eff . Pk 61 .E % 0.7 ff. Eff 200 300 RPM 0.5 100 0.4 0.6 0.8 1 0.0020.003 0.005 0.0070.01 2 4 6 qv - Flow (m³ / sec) 0.02 0.03 0.050.07 0.1 0.2 0.3 8 10 0.5 0.7 Pd - Fan Velocity Pressure (Pa) (in Thousands) 1 1.5 2 3 5 7 10 qv - Flow (CFM) (in Thousands) 15 20 20 1 2 3 30 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 57 PerformanceCurves RBW 926 1450 RPM 6,000 20 0 11 Lw 4,000 132kW A 15 110kW 5 10 90kW Lw A 960 RPM 75kW 0 10 10 55kW Lw A 2,000 45kW A 1,000 15kW A Lw 800 500 RPM 11kW Lw A 600 7.5kW 5.5kW A Lw PF - Fan Total Pressure (Pa) A Lw 22kW 18.5kW 80 PF - Fan Total Pressure (in W.G.) Lw 30kW 75 2 37kW 85 3 720 RPM 90 5 95 7 1.5 400 4kW 70 Lw A 3kW 300 RPM 2.2kW . 59 0.7 1.1kW 1.5kW % 66 Eff % 200 0.75kW Pk 61 % .E ff. Eff . 1 0.5 100 0.6 2 1.5 0.8 1 3 5 2 2 7 10 3 20 4 qv - Flow (m³ / sec) 30 50 70 100 6 8 200 300 Pd - Fan Velocity Pressure (Pa) 5 7 10 15 qv - Flow (CFM) (in Thousands) 10 20 500 700 1000 20 2000 30 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 58 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 1450 RPM 8,000 30 5 11 6,000 Lw A 20 0 11 Lw A 4,000 15 160kW 960 RPM 5 10 132kW Lw 90kW A 55kW Lw 45kW A 37kW 30kW A Lw 1,000 22kW 500 RPM 18.5kW 800 A PF - Fan Total Pressure (Pa) Lw 720 RPM Lw 3 2,000 90 5 75kW 95 7 0 10 10 85 PF - Fan Total Pressure (in W.G.) A 110kW PerformanceCurves RBW 929 10,000 15kW 80 11kW Lw A 600 7.5kW 75 2 A Lw 5.5kW 400 70 300 RPM .E ff. Eff % 1.5kW 3kW % 67 Eff % . Pk 62 1 4kW A Lw . 1.5 2.2kW 60 200 1 2 5 7 10 3 4 6 8 qv - Flow (m³ / sec) 20 5 30 50 70 100 10 200 300 Pd - Fan Velocity Pressure (Pa) 7 10 15 20 qv - Flow (CFM) (in Thousands) 20 500 700 1000 30 2000 50 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 59 960 RPM 0 11 PerformanceCurves RBW 933 20 Lw A 4,000 15 5 10 Lw A 132kW 720 RPM 110kW 0 10 10 Lw 90kW A 2,000 75kW 95 7 Lw A 55kW Lw A A 18.5kW 15kW Lw A 600 11kW 300 RPM A PF - Fan Total Pressure (Pa) 90 22kW Lw 800 Lw 1.5 30kW 1,000 80 2 37kW 85 3 500 RPM 75 PF - Fan Total Pressure (in W.G.) 45kW 5 7.5kW 400 70 5.5kW A Lw 4kW 65 1 A Lw 3kW 0.75kW .E % ff. Eff . 2.2kW 1.1kW 1.5kW % 66 Eff . % Pk 61 0.7 200 200 RPM 59 0.5 100 1 2 2 3 5 3 7 4 6 8 qv - Flow (m³ / sec) 10 5 20 30 50 70 100 10 20 200 300 500 700 1000 Pd - Fan Velocity Pressure (Pa) 7 10 15 20 qv - Flow (CFM) (in Thousands) 30 50 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 60 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 960 RPM 20 0 11 Lw A 4,000 15 5 10 Lw 720 RPM A 160kW 132kW 0 10 10 Lw A 2,000 90kW 95 7 A 30kW Lw A 800 22kW 18.5kW 80 Lw 600 A PF - Fan Total Pressure (Pa) Lw 37kW 1,000 15kW 300 RPM 11kW A Lw PF - Fan Total Pressure (in W.G.) A 90 45kW 75 2 55kW 85 3 75kW Lw 500 RPM 5 110kW PerformanceCurves RBW 937 1.5 400 7.5kW 70 A Lw Eff 1.5kW 2.2kW 59 % 66 Eff % 0.7 3kW . Pk 61 .E % A 200 4kW Lw . 65 200 RPM ff. 1 5.5kW 0.5 100 1 2 2 3 3 5 4 7 5 10 6 8 10 20 qv - Flow (m³ / sec) 20 30 50 70 100 200 300 Pd - Fan Velocity Pressure (Pa) 7 10 15 20 qv - Flow (CFM) (in Thousands) 30 500 700 1000 50 70 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 61 30 960 RPM 5 11 PerformanceCurves RBW 941 8,000 Lw 6,000 A 20 0 11 Lw A 4,000 15 720 RPM 5 10 Lw A Lw 110kW Lw 90kW A 75kW A Lw 55kW 45kW 1,000 37kW A Lw 3 500 RPM 90 5 PF - Fan Total Pressure (Pa) A 132kW 95 7 2,000 85 PF - Fan Total Pressure (in W.G.) 160kW 0 10 10 800 22kW 80 300 RPM 30kW Lw A 600 2 18.5kW 15kW 75 A Lw 1.5 11kW 400 70 Eff . Eff . Eff . % 3kW 4kW 2 4 5 5 7 10 7 6 20 10 60 % 67 200 5.5kW 2.2kW Pk . 62 % 1 7.5kW A Lw 200 RPM 8 10 20 qv - Flow (m³ / sec) 30 50 70 100 200 300 Pd - Fan Velocity Pressure (Pa) 15 20 30 qv - Flow (CFM) (in Thousands) 40 500 700 1000 50 70 2000 100 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 62 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 0 12 960 RPM Lw 8,000 A 30 PerformanceCurves RBW 945 10,000 5 11 Lw 6,000 A 20 0 11 720 RPM Lw A 4,000 15 5 10 Lw A 0 10 10 Lw 500 RPM A A 45kW Lw A 300 RPM 800 37kW 30kW Lw 600 A PF - Fan Total Pressure (Pa) Lw Lw 55kW 1,000 80 2 90kW 75kW 85 3 110kW 90 5 95 7 132kW 22kW 18.5kW 75 PF - Fan Total Pressure (in W.G.) A 160kW 2,000 15kW A Lw 1.5 400 200 RPM 70 11kW A Lw 7.5kW 65 1 5.5kW Lw A 150200 RPM 4kW . . Eff Eff 1.5kW Eff . 2.2kW 3kW 60 % 67 % 62 Pk . % 0.7 0.5 100 2 4 3 5 5 7 7 6 10 20 8 10 qv - Flow (m³ / sec) 30 50 70 100 20 40 200 300 Pd - Fan Velocity Pressure (Pa) 10 15 20 30 qv - Flow (CFM) (in Thousands) 50 60 500 700 1000 70 2000 100 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 63 PerformanceCurves RBW 949 720 RPM 0 11 20 Lw A 4,000 15 5 10 Lw A 500 RPM 0 10 10 Lw A 2,000 160kW 95 7 Lw 132kW A 55kW Lw 45kW A 800 37kW 30kW Lw 600 A PF - Fan Total Pressure (Pa) Lw 300 RPM 22kW 200 RPM A 400 18.5kW Lw 1.5 1,000 80 2 75kW 85 3 90kW 90 5 75 PF - Fan Total Pressure (in W.G.) A 110kW 15kW 70 A Lw 11kW 2.2kW 5.5kW 3kW 4kW 59 % 66 Eff % 0.7 . Pk 61 .E % A Eff . Lw 200 7.5kW 65 150 RPM ff. 1 0.5 100 2 4 2 3 5 5 7 6 7 10 10 8 10 qv - Flow (m³ / sec) 20 30 50 70 100 20 40 200 300 Pd - Fan Velocity Pressure (Pa) 15 20 30 qv - Flow (CFM) (in Thousands) 50 60 500 700 1000 70 100 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 64 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 15 PerformanceCurves RBW 954 4,000 5 10 500 RPM Lw A 0 10 10 Lw A 2,000 95 7 Lw 160kW A A 90kW 75kW 1,000 Lw A 55kW 800 45kW 37kW Lw 600 A PF - Fan Total Pressure (Pa) Lw 300 RPM 85 3 110kW 90 5 80 PF - Fan Total Pressure (in W.G.) 132kW 30kW 200 RPM 2 75 A Lw 22kW 1.5 18.5kW 400 15kW 70 A Lw 150 RPM 4kW Eff 5.5kW 4 3 7 6 5 7 10 8 10 10 7.5kW 59 % 200 . 66 % Pk 61 % 1 .E ff. Eff . 11kW 3kW qv - Flow (m³ / sec) 20 30 50 70 20 40 100 Pd - Fan Velocity Pressure (Pa) 15 20 30 50 qv - Flow (CFM) (in Thousands) 200 60 300 500 700 70 100 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. www.tcf.com 65 PerformanceCurves RBW 960 20 500 RPM 4,000 15 5 10 Lw A 0 10 10 Lw A 2,000 Lw Lw A 110kW 1,000 90kW 75kW A Lw PF - Fan Total Pressure (Pa) A 132kW 85 3 160kW 90 5 300 RPM 800 55kW 200 RPM 45kW A Lw 600 80 PF - Fan Total Pressure (in W.G.) 95 7 37kW 2 75 30kW A Lw 400 22kW 150 RPM 18.5kW 5.5kW Pk . 61 % Eff . Eff . 1.5 15kW Eff . 66 % 7.5kW 11kW 59 % 1 200 4 6 3 5 8 7 10 10 10 15 20 20 40 qv - Flow (m³ / sec) 30 50 70 100 200 50 70 Pd - Fan Velocity Pressure (Pa) 20 30 qv - Flow (CFM) (in Thousands) 300 60 80 500 700 1000 100 150 Fan Efficiency Grade = FEG 67 Notes: 1. 2. 3. 4. 5. 6. 7. 66 Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Twin City Fan Catalogue M902 DimensionalData RBO, RBA, & RBW, Arr. 9A & 9B, Class 22 HA NOTE 1 P HJ J JA NOTE 5 DX OUTSIDE DISCH FLANGE NOTE 1 Q NOTE 4 B KL SD D DISCH CL HC HN DISCH CL A HOUSING KS KWY SIZE SE C O.D. INLET GA GA. SIDES CL DISCH HE GB DIA. SHAFT GA. SCROLL BA BASE ANGLE GC CW THD ROTATABLE G HB HK HF HD HH HB HK HD D CW TAU M K CL FAN SHAFT SIX ‘BH’ DIA. BASE HOLES L FAN SIZE 907 909 911 913 915 917 919 A B 173 219 268 316 363 413 459 154 195 240 283 325 368 410 FAN SIZE 907 909 911 913 915 917 919 9A 630 672 833 876 1068 1111 1213 9B 722 887 957 1060 1129 1235 1314 K KL 103 124 152 173 202 222 243 114 127 127 140 140 152 178 H BA 38 38 51 51 64 64 64 x x x x x x x 38 38 51 51 64 64 64 HA HJ HF HK HH HG D D CW BHD CW BAU CW UBD HE NOTES: 1. Outlet flanges are optional. Flanges are punched per drawing AC15146. 2. CW rotation is shown. CCW rotation is similar but opposite. 3. For 'DBD' (downblast) see drawing AC15071. 4. Motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. Dimension 'FR' is Max. Motor Frame. 5. Optional flanged inlet per drawing AC15143. M FAN C HSG L K HB D D FOUNDATION PLAN HG HA HJ CW TAD FAN SIZE 907 909 911 913 915 917 919 HC HN WITH OPTIONAL FLANGED INLET N H BH C 11 11 14 14 14 14 14 178 229 279 330 381 432 483 D 9A 470 470 546 552 641 718 794 9B 546 622 635 705 718 813 902 FR DX 9A 112M 112M 132M 132M 160L 160L 180L 32 32 38 38 38 38 51 9B 132M 160L 160L 180L 180L 200L 225M G GA GB GC 362 451 514 591 667 749 794 2.5 2.5 3 3 3 3 3 2.5 2.5 3 3 3 3 3 181 226 257 295 334 375 397 HA HB HC HD HE HF HG HH HJ HK HN J JA 224 283 343 403 464 524 583 372 465 565 662 757 854 956 300 375 456 532 607 683 768 257 329 400 473 545 617 687 246 314 383 452 521 591 657 235 300 365 432 497 564 627 224 286 348 411 473 537 597 213 272 330 391 449 510 567 211 270 330 391 451 511 570 340 433 530 626 721 818 911 268 343 418 494 568 645 718 119 140 175 195 230 251 272 145 165 213 233 256 276 297 M N Q SD SE 162 207 232 270 302 343 365 16 16 22 22 29 29 29 183 233 284 337 387 438 489 35 35 40 40 55 55 55 121 140 140 152 152 178 191 L KS 10 10 10 10 13 13 13 x x x x x x x 5 5 5 5 6 6 6 9A 386 386 478 480 602 603 664 9B 478 602 602 664 662 727 765 P 9A 632 672 799 833 991 1038 1132 9B 724 887 922 1018 1051 1162 1233 IMPELLER DIAMETER 311 397 486 575 664 753 838 AC15074 Dimensions are not to be used for construction. Dimensions are in millimeters unless otherwise noted. Certified drawings are available upon request. www.tcf.com 67 GA HE HA J P JA NOTE 4 GA. SIDES HC NOTE 3 SD A HOUSING CL DISCH KWY SIZE C SE O.D. INLET KS KL D MOTOR ARR 9 ONLY OUTSIDE DISCH FLANGE NOTE 1 Q DISCH CL B DX DISCH CL GB DIA. SHAFT GA. SCROLL BA BASE ANGLE GC CW THD NON-ROTATABLE G HF HP HG HE NOTE 5 KA KB CL L HF HB HA HE HH HG D D D CW TAU CW BAU CW UBD CW BHD AH HSG C L FAN SHAFT FAN HG HA CW TAD M HC D D CW DBD M HH WITH OPTIONAL FLANGED INLET N H HB HD D NOTE 1 HD HB NOTES: 1. Outlet flanges punched per drawing AC15146 except 'DBD' is punched per foundation plan. 'DBD' "punched" outlet is per drawing AC15392. 2. CW rotation is shown. CCW rotation is similar but opposite. 3. Arrangement 9 motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. Dimension 'FR' is Max. Motor Frame on Arr. 9A. 4. Optional flanged inlet per drawing AC15143. 5. Use dimension 'KB' for 'DBD'. DBD ONLY DimensionalData RBO, RBA, & RBW, Arr.1 & 9A, Class 22 SIX ‘BH’ DIA. BASE HOLES (EIGHT HOLES ON ‘DBD’) FOUNDATION PLAN FAN SIZE 921 923 926 929 A AH B 508 559 630 703 400 440 492 548 452 499 562 626 FAN SIZE 921 923 926 929 GC H HA HB HC HD HE HF HG HH HP J JA 473 511 568 632 1343 1389 1491 1554 597 673 737 806 1021 1129 1261 1394 845 922 1045 1164 759 833 938 1051 724 794 895 1003 689 756 852 954 654 716 810 907 619 678 767 857 870 948 1057 1176 308 330 362 394 334 356 387 419 KA KB KL KS L M N P Q SD SE 273 295 327 359 268 291 322 354 178 178 203 203 16 x 8 16 x 8 19 x 10 22 x 11 725 727 765 765 435 473 530 594 35 35 35 35 1238 1262 1357 1402 540 592 667 749 60 60 75 80 203 203 229 241 FAN SIZE 921 923 926 929 BA 76 76 76 76 x x x x 76 76 76 76 BH C D DX 21 21 21 21 533 584 660 737 876 953 1060 1181 51 51 64 64 FR (9A) 200L 200L 225M 225M G GA GB 946 1022 1137 1264 3 5 5 5 3 5 5 5 IMPELLER DIAMETER 927 1016 1146 1283 AC15063 Dimensions are not to be used for construction. Dimensions are in millimeters unless otherwise noted. Certified drawings are available upon request. 68 Twin City Fan Catalogue M902 DimensionalData RBO, RBA, & RBW, Arr. 9B, Class 22 HA HE GA J P JA NOTE 4 DX KS KL SD D A HOUSING KWY SIZE C SE O.D. INLET Q NOTE 3 B OUTSIDE DISCH FLANGE NOTE 1 HC CL DISCH DISCH CL DISCH CL GA. SIDES GB DIA. SHAFT GA. SCROLL BA BASE ANGLE GC CW THD NON-ROTATABLE G HP HG HF HE D NOTE 1 M L HA HE HH HG D D CW BAU CW BHD HA CW TAU CW TAD CW UBD AH DBD ONLY HSG C L FAN SHAFT KB HF HB D M CL HG HC D D KA FAN HH HB HD CW DBD NOTE 5 HD HB WITH OPTIONAL FLANGED INLET N H NOTES: 1. Outlet flanges punched per drawing AC15146 except angles on 'DBD' punched per foundation plan. 2. CW rotation is shown. CCW rotation is similar but opposite. 3. Motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. Dimension 'FR' is Max. Motor Frame on Arr. 9B. 4. Optional flanged inlet per drawing AC15143. 5. Use dimension 'KB' for 'DBD'. SIX ‘BH’ DIA. BASE HOLES (EIGHT HOLES ON ‘DBD’) FOUNDATION PLAN FAN SIZE 921 923 926 929 A AH B 508 559 630 703 400 440 492 548 452 499 562 626 FAN SIZE 921 923 926 929 GC H HA HB HC HD HE HF HG HH HP J JA 473 511.00 568 632 1381 1427 1618 1681 597 673 737 806 1021 1129 1261 1394 845 922 1045 1164 759 833 938 1051 724 794 895 1003 689 756 852 954 654 716 810 907 619 678 767 857 870 948 1057 1176 308 330 362 394 334 356 387 419 KA KB KL KS L M N P Q SD SE 273 295 327 359 268 291 322 354 178 178 203 203 16 x 8 16 x 8 19 x 10 22 x 11 764 765 892 892 435 473 530 594 35 35 35 35 1276 1300 1484 1529 540 592 667 749 60 60 75 80 203 203 229 241 FAN SIZE 921 923 926 929 BA 76 76 76 76 x x x x 76 76 76 76 BH C D DX 21 21 21 21 533 584 660 737 1048 1048 1060 1181 51 51 64 64 FR (9B) 225M 225M 250M 250M G GA GB 946 1022 1137 1264 3 5 5 5 3 5 5 5 IMPELLER DIAMETER 927 1016 1146 1283 AC15075A Dimensions are not to be used for construction. Dimensions are in millimeters unless otherwise noted. Certified drawings are available upon request. www.tcf.com 69 HE HA GA J P JA NOTE 4 GA. SIDES DX DC NOTE 3 SD DISCH CL KS KWY SIZE SE C GB GA. SCROLL DIA. SHAFT BA BASE ANGLE GC HG CW THD NON-ROTATABLE G NOTE 1 HB HD DA DB DD CW TAD CW DBD M KA KB CL L WITH OPTIONAL FLANGED INLET HG HA HF HB HA HH DE DF CW TAU HG DG CW BAU CW UBD HE CW BHD AH HSG C L FAN SHAFT FAN M HC HB HF N H HH HD HP HE NOTE 5 KL A HOUSING O.D. INLET HC Q MOTOR ARR 9 ONLY B OUTSIDE DISCH FLANGE NOTE 1 C L DISCH DISCH CL DBD ONLY DimensionalData RBO, RBA, & RBW, Arr. 1 & 9, Class 22 NOTES: 1. Outlet flanges punched per drawing AC15146 except 'DBD' is punched per foundation plan. 'DBD' "punched" outlet is per drawing AC15392. 2. CW rotation is shown. CCW rotation is similar but opposite. 3. Arrg. 9 motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. Dimension 'FR' is Max. Motor Frame on Arr. 9. 4. Optional flanged inlet per drawing AC15143. 5. Use dimension 'KB' for 'DBD'. SIX ‘BH’ DIA. BASE HOLES (EIGHT HOLES ON ‘DBD’) FOUNDATION PLAN FAN SIZE 933 937 941 945 949 954 960 A AH B BA BH C DA DB DC DD DE DF DG DX 800 894 989 1086 1184 1299 1448 657 730 829 902 886 957 1065 711 800 884 970 1054 1156 1289 76 x 102 76 x 102 89 x 127 102 x 152 102 x 152 102 x 152 102 x 152 21 21 21 21 21 21 21 838 940 1041 1143 1245 1388 1540 1092 1216 1340 1499 1626 1784 1981 1092 1216 1340 1499 1626 1784 1981 1092 1216 1340 1499 1626 1784 1981 1143 1283 1403 1575 1702 1867 2076 1194 1346 1480 1651 1772 1956 2172 1257 1416 1549 1727 1880 2057 2286 1334 1486 1632 1829 2032 2184 2438 64 64 64 76 76 76 76 FAN SIZE 933 937 941 945 949 954 960 FR (ARR. 9) 250M 250M 250M 250M 250M 250M 250M G GA GB GC H HA HB HC HD HE HF HG HH HP 1372 1524 1664 1854 2197 2400 2664 5 6 6 6 6 8 8 5 5 5 5 6 8 8 686 762 832 927 1099 1200 1332 1819 1908 2043 2180 2264 2367 2500 927 1035 1232 1265 1378 1505 1681 1586 1767 2013 2151 2340 2553 2846 1314 1464 1613 1775 1930 2103 2343 1195 1338 1481 1624 1772 1938 2167 1140 1276 1413 1549 1691 1849 2067 1084 1214 1345 1475 1608 1760 1967 1029 1153 1276 1400 1527 1672 1867 973 1091 1208 1326 1445 1583 1767 1353 1502 1676 1851 2007 2180 2419 J JA KA KB KL L M N P Q SD SE 464 508 576 645 686 738 805 489 533 602 670 711 764 830 416 461 516 572 613 665 732 410 454 510 565 607 657 724 8 8 8 8 8 8 8 892 892 891 891 892 892 892 648 724 787 876 1048 1149 1281 48 48 60 73 73 73 73 1604 1648 1715 1783 1826 1878 1945 851 954 1056 1157 1262 1378 1543 87 87 100 100 113 138 151 241 241 241 241 241 241 241 FAN SIZE 933 937 941 945 949 954 960 KS 22 22 25 25 25 32 38 x x x x x x x 11 11 13 13 13 16 19 IMPELLER DIAMETER 1461 1635 1810 1988 2165 2381 2648 AC15064A Dimensions are not to be used for construction. Dimensions are in millimeters unless otherwise noted. Certified drawings are available upon request. 70 Twin City Fan Catalogue M902 DimensionalData RBO, RBA, & RBW, Arr. 1 & 9, Class 32 HA HE NOTE 1 J P HJ GA JA NOTE 4 GA. SIDES DX HN MOTOR ARR 9 ONLY SD KWY SIZE C SE O.D. INLET KS KL D A OUTSIDE HOUSING CL DISCH Q NOTE 3 B DISCH FLANGE NOTE 1 DISCH CL HC DISCH CL GB DIA. SHAFT GA. SCROLL BA BASE ANGLE GC CW THD NON-ROTATABLE G HD HB HK HF HH HB HD CW TAU CW TAD KA KB HG D D CW BHD M CL L HH CW BAU CW UBD NOTES: 1. Outlet flanges are optional. Flanges are punched per drawing AC15147. 2. CW rotation is shown. CCW rotation is similar but opposite. 3. Arrg. 9 motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. Dimension 'FR' is Max. Motor Frame on Arr. 9. 4. Optional flanged inlet per drawing AC15143. 5. For 'DBD' (downblast) see drawing AC15072. HSG C L FAN SHAFT FAN HE HA HJ HF HK D D M HB HA HJ HK D HG HC HN WITH OPTIONAL FLANGED INLET N H SIX ‘BH’ DIA. BASE HOLES (EIGHT HOLES ON ‘DBD’) FOUNDATION PLAN FAN SIZE 911 913 915 917 919 A B 272 319 367 416 462 243 286 329 372 413 FAN SIZE 911 913 915 917 919 ARR. 1 722 797 973 1067 1172 ARR. 9 1024 1111 1199 1280 1461 K KL KS 156 176 205 226 246 137 152 152 168 203 13 x 6 13 x 6 16 x 8 16 x 8 19 x 10 FAN SIZE 911 913 915 917 919 H BA 51 51 64 64 64 x x x x x 51 51 64 64 64 BH C 14 14 14 21 21 279 330 381 432 483 D ARR. 1 476 552 641 718 794 ARR. 9 705 813 813 914 1048 DX 38 38 38 38 51 FR (ARR. 9) 160L 180L 180L 200L 225M G GA GB GC 514 591 667 749 794 5 5 5 5 5 5 5 5 5 5 257 295 334 375 397 HA HB HC HD HE HF HG HH HJ HK HN J JA 343 403 464 524 583 567 664 759 856 957 457 533 608 684 770 402 475 546 619 689 384 454 522 592 659 367 433 499 565 629 349 413 475 538 598 332 392 451 511 568 330 391 451 511 570 530 627 722 819 913 419 495 570 646 719 178 198 233 254 275 216 236 259 279 300 M N Q SD SE 232 270 302 343 365 22 22 29 29 29 284 337 387 438 489 50 50 60 60 75 152 171 171 194 232 L ARR. 1 360 394 500 552 616 ARR. 9 662 708 725 765 905 P ARR. 1 697 770 911 1007 1129 ARR. 9 998 1084 1137 1219 1418 IMPELLER DIAMETER 486 575 664 753 838 AC15065 Dimensions are not to be used for construction. Dimensions are in millimeters unless otherwise noted. Certified drawings are available upon request. www.tcf.com 71 GA HA HE P J JA NOTE 4 B DX DISCH FLANGE NOTE 1 HC Q NOTE 3 MOTOR ARR 9 ONLY KS KL SD D A OUTSIDE HOUSING KWY SIZE C SE O.D. INLET DISCH CL DISCH CL GA. SIDES CL DISCH DimensionalData RBA, RBO, RBP, & RBW, Arr. 1 & 9, Class 32 GB DIA. SHAFT GA. SCROLL BA BASE ANGLE GC HG HP CW THD NON-ROTATABLE G HF HE HD HB HC HB HD D HH WITH OPTIONAL FLANGED INLET N H HG HF HB HE HH HA HG D D D HA D D NOTE 1 CW DBD M KA FAN HSG C L FAN SHAFT KB CL L CW BHD CW BAU CW UBD AH M DBD ONLY NOTE 5 CW TAU CW TAD NOTES: 1. Outlet flanges punched per drawing AC15147 except 'DBD' is punched per foundation plan. 'DBD' "punched" outlet is per drawing AC15393. 2. CW rotation is shown. CCW rotation is similar but opposite. 3. Arrg. 9 motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. Dimension 'FR' is Max. Motor Frame on Arr. 9. 4. Optional flanged inlet per drawing AC15143. 5. Use dimension 'KB' for 'DBD'. SIX ‘BH’ DIA. BASE HOLES (EIGHT HOLES ON ‘DBD’) FOUNDATION PLAN FAN SIZE 921 923 926 929 FAN SIZE 921 923 926 929 FAN SIZE 921 923 926 929 A AH B 511 559 633 706 402 440 494 549 456 502 565 629 GC BA 76 76 76 76 H 473 511 568 632 ARR. 1 1261 1346 1435 1524 K KL 270 292 324 356 203 203 203 203 ARR. 9 1524 1572 1635 1699 x x x x 76 76 76 76 C 21 21 21 21 533 584 660 737 D ARR. 1 876 953 1060 1181 DX ARR. 9 1048 1048 1060 1181 51 51 64 64 FR (ARR. 9) 225M 225M 250M 250M G GA GB 946 1022 1137 1264 5 6 6 6 5 5 6 6 HA HB HC HD HE HF HG HH HP J JA KA 597 673 737 806 1021 1129 1262 1395 846 922 1046 1165 760 833 940 1053 725 794 897 1005 691 756 854 956 656 716 811 908 621 678 768 859 871 948 1059 1178 310 334 365 397 335 359 391 422 275 298 330 362 M N Q SD SE 435 473 530 594 35 35 35 35 540 592 665 749 75 90 90 100 232 235 235 238 L KS 19 22 22 25 x x x x BH 10 11 11 13 ARR. 1 640 679 705 730 ARR. 9 903 905 905 905 P ARR. 1 1183 1248 1305 1365 ARR. 9 1446 1473 1505 1540 IMPELLER DIAMETER 927 1016 1146 1283 AC15066 Dimensions are not to be used for construction. Dimensions are in millimeters unless otherwise noted. Certified drawings are available upon request. 72 Twin City Fan Catalogue M902 DimensionalData RBA, RBR, & RBW, Arr. 1 & 9, Class 32 HA HE J P GA JA NOTE 4 DX SD HF HE HD DA DB L CL HH DE DF CW UBD HE HG DG CW BHD CW BAU AH HSG C L FAN SHAFT FAN HA HF HB HA CW TAU DBD ONLY M M WITH OPTIONAL FLANGED INLET HG HC CW TAD N H HH DD CW DBD KB BA HB HB NOTE 1 KA GB GA. SCROLL CW THD NON-ROTATABLE G HD HP NOTE 5 SE C BASE ANGLE GC HG KWY SIZE DIA. SHAFT MOTOR ARR 9 ONLY OUTSIDE HOUSING KS KL DC A O.D. INLET Q NOTE 3 B DISCH FLANGE NOTE 1 HC CL DISCH DISCH CL DISCH CL GA. SIDES NOTES: 1. Outlet flanges punched per drawing AC15147 except 'DBD' is punched per foundation plan. 'DBD' "punched" outlet is per drawing AC15393. 2. CW rotation is shown. CCW rotation is similar but opposite. 3. Arrg. 9 motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. Dimension 'FR' is Max. Motor Frame on Arr. 9 4. Optional flanged inlet per drawing AC15143. 5. Use dimension 'KB' for 'DBD'. SIX ‘BH’ DIA. BASE HOLES (EIGHT HOLES ON ‘DBD’) FOUNDATION PLAN FAN SIZE 933 937 941 945 949 A AH B BA BH C DA DB DC DD DE DF DG DX 803 897 992 1089 1184 659 732 830 903 886 715 800 884 970 1054 76 x 102 76 x 102 89 x 127 102 x 152 102 x 152 21 21 21 21 21 838 940 1041 1143 1245 1092 1216 1340 1499 1626 1092 1216 1340 1499 1626 1092 1216 1340 1499 1626 1143 1283 1403 1575 1702 1194 1346 1480 1651 1772 1257 1416 1549 1727 1880 1334 1486 1632 1829 2032 64 64 64 76 76 FAN SIZE 933 937 941 945 949 FR (ARR. 9) 250M 250M 250M 250M 250M G GA GB H HA HB HC HD HE HF HG HH HP 1372 1524 1664 1854 2197 6 6 6 6 6 6 6 6 6 6 1822 1908 2045 2181 2264 927 1035 1232 1265 1378 1588 1769 2013 2151 2340 1316 1465 1614 1776 1930 1197 1340 1483 1626 1772 1141 1278 1415 1551 1691 1086 1216 1346 1477 1608 1030 1154 1278 1402 1527 975 1092 1210 1327 1445 1354 1503 1678 1853 2007 J JA KA KB L M N P Q SD SE 465 508 578 646 687 490 533 603 672 713 418 461 516 572 613 411 454 510 565 607 892 892 892 892 892 648 724 787 876 1048 48 48 60 73 73 1595 1642 1710 1778 1819 851 954 1056 1157 1262 100 125 125 125 140 238 241 241 241 241 FAN SIZE 933 937 941 945 949 KS 25 32 32 32 32 x x x x x 13 16 16 16 16 IMPELLER DIAMETER 1461 1635 1810 1988 2165 AC15067A Dimensions are not to be used for construction. Dimensions are in millimeters unless otherwise noted. Certified drawings are available upon request. www.tcf.com 73 J JA B A HF HP HE OUTSIDE HOUSING HD DA DB KS KL KWY SIZE CL DISCH. Q SE HB CL HC HG DISCH. P CW DBD C CW TAD HH HD O.D. INLET HC HB SD HG HA DIA. SHAFT DC DE DD CW TAU N G HB WITH OPTIONAL FLANGED INLET H NOTE 6 KA CL T M KB KB L L T CL CL FAN SHAFT M S "BH" DIA. BASE HOLES CL CL T FAN HSG. CL KB FAN HSG. MOTOR MOTOR L CL S FAN SIZE 911 913 915 917 919 921 923 926 929 933 937 941 945 949 FAN SIZE 911 913 915 917 919 921 923 926 929 933 937 941 945 949 M AH AH M M DBD ONLY "BH" DIA. BASE HOLES M S FAN SIZE 911 913 915 917 919 921 923 926 929 933 937 941 945 949 CW BHD SIZES 921 – 949 (ALL DISCHARGES) FAN HSG. K DG CW BAU SIZES 911 – 919 (DBD ONLY) "BH" DIA. BASE HOLES K HG DF MOTOR SIZES 911 – 919 (ALL DISCHARGES EXCEPT DBD) HE HA HH NOTES: 1. Clockwise (CW) rotation shown. Counterclockwise (CCW) rotation is similar but opposite. 2. Sizes 911 through 919 are rotatable. Sizes 921 through 949 are non-rotatable. 3. Optional flanged inlet is shown. See page 38 for dimensional data. 4. Punched outlet flange is optional on sizes 911 through 919 and standard on sizes 921 through 949. See page 38 for dimensional data. 5. Standard Arr. 9F motor location is on the left for CW rotation units, and on the right for CCW rotation units (unless otherwise specified.) 6. Use dimension KB in place of KA for DBD. CW UBD HF FAN SHAFT CW THD CW THD /2 G CL 1 V CL FAN SHAFT DimensionalData Arr. 9F, Class 32 HA HE A AH B BH C DA DB DC DD DE DF DG G 272 319 367 416 462 511 559 633 706 803 897 992 1089 1184 216 254 303 338 389 402 440 494 549 659 732 830 903 886 243 286 329 372 413 456 502 565 629 715 800 884 970 1054 14 14 14 21 21 21 21 21 21 21 21 21 21 21 279 330 381 432 483 533 584 660 737 838 940 1041 1143 1245 476 552 641 718 794 876 953 1060 1181 1092 1216 1340 1499 1626 476 552 641 718 794 876 953 1060 1181 1092 1216 1340 1499 1626 476 552 641 718 794 876 953 1060 1181 1092 1216 1340 1499 1626 476 552 641 718 794 876 953 1060 1181 1143 1283 1403 1575 1702 476 552 641 718 794 876 953 1060 1181 1194 1346 1480 1651 1772 476 552 641 718 794 876 953 1060 1181 1257 1416 1549 1727 1880 476 552 641 718 794 876 953 1060 1181 1334 1486 1632 1829 2032 514 591 667 749 794 946 1022 1137 1264 1372 1524 1664 1854 2197 DBD 979 1084 1154 1237 1462 1537 1726 1789 1853 1989 2075 2297 2408 2491 H OTHERS 989 1094 1164 1246 1472 1537 1726 1789 1853 1989 2075 2297 2408 2491 HA 343 403 464 524 583 597 673 737 806 927 1035 1232 1265 1378 HB HC HD HE HF HG HH HP J JA K KA KB KL KS 567 664 759 856 957 1021 1129 1261 1394 1586 1769 2013 2153 2340 457 533 608 684 770 846 922 1046 1165 1316 1465 1614 1778 1930 402 475 546 619 689 760 833 940 1053 1197 1340 1483 1626 1772 384 454 522 592 659 725 794 897 1005 1141 1278 1415 1551 1691 367 433 499 565 629 691 756 854 956 1086 1216 1346 1477 1608 349 413 475 538 598 656 716 811 908 1030 1154 1276 1402 1527 332 392 451 511 568 621 678 768 859 975 1092 1210 1327 1445 470 546 633 710 783 871 948 1059 1178 1354 1503 1678 1854 2007 178 198 233 254 275 310 334 365 397 465 508 578 646 687 216 236 259 279 300 335 359 391 422 490 533 603 672 713 156 176 205 226 246 — — — — — — — — — — — — — — 275 298 330 362 418 461 516 572 613 — — — — — 270 292 324 356 411 454 510 565 607 137 152 152 168 203 203 235 235 235 235 235 235 235 235 13 x 6 13 x 6 16 x 8 16 x 8 19 x 10 19 x 10 22 x 11 22 x 11 25 x 13 25 x 13 32 x 16 32 x 16 32 x 16 32 x 16 DBD 591 654 654 695 876 876 1019 1019 1019 1019 1019 1105 1080 1080 L OTHERS 594 654 654 695 876 876 1019 1019 1019 1019 1019 1105 1080 1080 M N 232 270 302 343 365 435 473 530 594 648 724 787 876 1048 22 22 29 29 29 35 35 35 35 48 48 60 73 73 DBD 926 1026 1060 1145 1384 1419 1619 1651 1686 1754 1800 1954 1997 2038 P OTHERS 930 1030 1065 1149 1389 1419 1619 1651 1686 1754 1800 1954 1997 2038 Q S SD SE 284 337 387 438 489 540 592 667 749 851 954 1056 1156 1261 775 883 889 994 1124 1130 1219 1219 1219 1219 1219 1226 1232 1232 49 49 62 62 75 75 87 87 100 100 125 125 125 138 152 171 171 194 232 232 267 267 270 270 273 273 273 273 DBD 533 597 591 632 813 806 949 949 949 937 937 1010 972 972 T OTHERS 537 597 591 632 813 806 949 949 949 937 937 1010 972 972 DBD 1041 1187 1226 1372 1524 1600 1727 1784 1848 1902 1978 2048 2143 2315 V MAX. MOTOR OTHERS FRAME SIZE 1041 180L 1187 200L 1226 200L 1372 225M 1524 250M 1600 250M 1727 280M 1784 280M 1848 280M 1902 280M 1978 280M 2048 280M 2143 280M 2315 280M AC15072F AC15136A AC15137A AC15138B Dimensions are not to be used for construction. Dimensions are in millimeters unless otherwise noted. Certified drawings are available upon request. 74 Twin City Fan Catalogue M902 DimensionalData Arrangement 10 Size 905 HE HA P 1.75 TYP. J B HD OUTS. HSG. A DISCH. CL HC CL SHAFT OUTS. HSG. Q HC SE KL KS KWY SIZE C CL HSG. FOUNDATION PLAN TOP VIEW KA SD DIA. SHAFT D D CL SHAFT CL SHAFT D HB HA O.D. INLET (4) BH DIA. BASE HOLES KB CW TAU HG HE 3.13 M M CL SHAFT CW UBD HA CL HSG. HH HG HN HG HE GC G H D D CL SHAFT CL SHAFT CW BHD CW DBD Sizes 907 – 919 HG HF HP HA HE HE NOTE 1 P HJ GA JA J HB HD NOTE 3 GA. SIDES HC HN DX B DISCH. FLANGE NOTE 1 OPTIONAL WEATHER COVER KL Q DISCH. C D L OUTSIDE HOUSING M A D M CW DBD KS KWY SIZE KA CW TAD HH HD FAN HSG. HC C O.D. INLET MOTOR "FR" MAX. FRAME SE 1.00 TYP. D CL FAN SHAFT CL KB SD DIA. SHAFT GB L GA. SCROLL HB N CW THD ROTATABLE G HA D D BA BASE ANGLE GC HG FOUNDATION PLAN (6) "BH" DIA. BASE HOLES WITH OPTIONAL FLANGED INLET H CW TAU HB CW UBD HF HA HE HH HG D D CW BAU CW BHD NOTES: 1. Clockwise (CW) rotation shown, counterclockwise (CCW) rotation is similar but opposite. 2. All sizes are rotatable. 3. Optional flanged inlet shown on sizes 907 through 919. An optional flanged inlet is available on all Arrangement 10 sizes, including size 905. See page 38 for dimensional data. 4. Punched outlet flange is optional on all sizes. See page 38 for dimensional data. 5. Weather cover is optional. 6. All Arrangement 10 fans are available as Class 22 only. FAN SIZE 905 907 909 911 913 915 917 919 FAN SIZE 905 907 909 911 913 915 917 919 A B BH C D G GC H HA HB HC HD HE HF HG HH 124 173 219 268 316 363 413 459 114 154 195 240 283 325 368 410 11 11 11 14 14 14 14 14 127 178 229 279 337 387 438 489 368 448 492 556 648 775 699 762 406 406 483 635 692 838 918 988 203 203 241 318 346 419 459 494 340 727 813 991 1034 1146 1189 1319 229 243 283 362 403 464 524 583 298 384 465 578 662 757 854 956 203 300 375 456 532 607 683 768 203 257 329 400 473 546 617 687 203 246 314 383 452 521 591 657 — 235 300 365 432 497 564 627 203 224 286 348 411 473 537 597 203 213 272 330 391 449 510 567 HN J JA KA KB KL KS L M N P Q SD SE 203 268 343 418 494 568 645 718 99 119 140 175 195 230 251 272 — 145 165 213 233 256 276 297 171 103 124 152 173 202 222 243 171 125 146 171 208 230 265 286 51 51 67 83 83 92 92 114 6 x 3 10 x 5 10 x 5 10 x 5 10 x 5 13 x 6 13 x 6 13 x 6 — 470 514 629 607 664 645 734 152 186 224 276 283 308 314 359 — 16 16 22 22 29 29 29 435 630 713 870 892 988 1011 1137 130 183 233 284 337 387 438 489 25 35 35 40 40 55 55 55 70 70 86 102 102 118 118 133 MAX. MTR. 90L 112M 132M 160L 160L 180L 180L 200L AC10726D Dimensions are not to be used for construction. Dimensions are in millimeters unless otherwise noted. Certified drawings are available upon request. www.tcf.com 75 DimensionalData Inlet & Outlet Flanges Inlet Flange C FAN SIZE 905 907 909 911 913 915 917 919 921 923 O.D. B A B.C. I.D. (D) "E" DIA. HOLES EQUALLY SPACED A B C D E 129 181 232 283 334 384 435 486 537 588 160 216 270 324 376 427 478 529 579 630 179 238 295 353 408 459 513 564 614 665 6 6 6 6 12 12 12 12 16 16 7 10 11 11 11 11 11 11 14 14 FAN SIZE 926 929 933 937 941 945 949 954 960 A B C D E 664 740 842 943 1045 1146 1248 1388 1540 724 800 902 1003 1105 1207 1308 1457 1610 765 842 943 1045 1146 1248 1350 1515 1667 16 16 24 24 32 32 32 32 32 14 14 14 14 14 14 14 21 21 AC15143B Outlet Flange A C A C J E "K" SP @ "L" B E (N) "M" DIA. HOLES D C B (N) "M" DIA. HOLES J D C "G" SP @ "H" F C SIZES 905 – 917 F C SIZES 919 – 960 Class 22 FAN SIZE 905 907 909 911 913 915 917 919 921 923 926 929 933 937 941 945 949 954 960 A B C D E F G H J K L M N 178 217 259 316 359 402 445 511 554 600 689 753 838 927 1011 1122 1207 1308 1441 187 236 283 344 392 440 489 560 610 660 757 830 927 1021 1116 1238 1337 1451 1600 13 13 13 16 16 16 16 22 22 22 29 29 29 29 29 35 35 35 35 — — 117 142 164 185 207 — — — — — — — — — — — — — — 129 156 180 204 229 — — — — — — — — — — — — — — — — — — — 156 170 186 211 232 195 217 239 212 226 248 276 — — — — — — — 1 1 1 1 1 2 2 2 3 3 3 3 — — — — — — — 156 170 184 210 232 195 217 238 210 229 248 273 — — — — — — — 169 189 205 176 193 219 241 282 260 272 233 257 — — — — — — — 1 1 1 2 2 2 2 2 3 3 4 4 — — — — — — — 178 187 207 175 194 216 241 248 216 241 229 254 10 10 10 11 11 11 11 14 14 14 14 14 14 14 14 14 14 14 14 4 4 8 8 8 8 8 12 12 12 14 14 16 16 16 20 20 22 22 AC15146C Class 32 FAN SIZE 911 913 915 917 919 921 923 926 929 933 937 941 945 949 ANGLE SIZE 32 x 32 32 x 32 32 x 32 38 x 38 38 x 38 38 x 38 38 x 38 51 x 51 51 x 51 51 x 51 64 x 64 64 x 64 64 x 64 64 x 64 64 x 64 76 x 76 76 x 76 76 x 76 76 x 76 A B C D E F G H J K L M N 319 362 405 448 514 557 603 692 756 842 927 1011 1122 1207 348 395 443 492 564 613 660 760 833 930 1024 1119 1241 1337 16 16 16 16 22 22 22 29 29 29 29 29 35 35 144 165 186 208 — — — — — — — — — — 158 182 205 230 — — — — — — — — — — — — — — 157 171 186 211 232 195 217 236 210 225 — — — — 1 1 1 1 1 2 2 2 3 3 — — — — 156 171 187 213 235 197 217 241 211 229 — — — — 169 189 205 176 195 219 242 283 252 252 — — — — 1 1 1 2 2 2 2 2 3 3 — — — — 181 191 207 176 194 217 241 248 222 254 11 11 11 11 14 14 14 14 14 14 14 14 14 14 8 8 8 8 12 12 12 14 14 16 16 16 20 20 ANGLE SIZE 38 x 38 38 x 38 38 x 38 38 x 38 51 x 51 51 x 51 51 x 51 64 x 64 64 x 64 64 x 64 64 x 64 64 x 64 76 x 76 76 x 76 AC15147 Dimensions are not to be used for construction. Dimensions are in millimeters unless otherwise noted. Certified drawings are available upon request. 76 Twin City Fan Catalogue M902 PERFORMANCE — Fans shall be tested in accordance with AMCA 210 test code for air moving devices and shall be guaranteed by the manufacturer to deliver rated published performance levels. RBO, RBR, RBW and RBA fans shall be licensed to bear the AMCA certified ratings seal for air and fan efficiency grade (FEG). HOUSING — Housings shall be continuously welded heavy gauge steel, suitably braced to prevent pulsation. Housings with lock seams or partially welded construction are not acceptable. Class 22 housings shall be constructed of a minimum 3 mm through 8 mm steel. Class 32 housings shall be constructed of at least 5 mm through 8 mm steel. Units having impeller diameters of 838 mm (size 919) and smaller shall be built with adjustable discharge housings which can be field rotated to any of the eight standard positions. Fans with impeller diameters larger than 838 mm shall be built with a fixed discharge housing and have a flanged type discharge to provide unit rigidity. TypicalSpecifications Fans shall be Model RBO/RBR/RBW/RBA/RBP Industrial Fans, as manufactured by Twin City Fan & Blower, Minneapolis, Minnesota. IMPELLER — All class 22 fan impellers shall be constructed of a minimum 3 mm through 19 mm thick steel. Class 32 fan impellers shall be constructed of a minimum 5 mm through 19 mm steel. The spider hubs for RBO impellers shall be fabricated steel or cast steel material. All industrial fan impellers shall be continuously welded. SHAFT — Shafts shall be AISI 1040 or 1045 hot rolled steel, accurately turned, ground, polished, and ring gauged for accuracy. Shafts shall be sized for the first critical speed of at least 1.43 times the maximum speed. BEARINGS — Bearings shall be heavy duty, grease lubricated, anti-friction ball or roller, self-aligning, pillow block type and selected for a minimum average bearing life (AFBMA L-50) in excess of 200,000 hours at the maximum fan RPM. V-BELT DRIVE — Fan and motor sheaves shall be cast iron fixed pitched drives for service over 7.5 kW. Small drives may use variable pitch cast iron motor sheaves. The minimum belt service factor is 120% for drives through 18.5 kW and 150% over 18.5 kW. FINISH AND COATING — The entire fan assembly, excluding the shaft, shall be thoroughly degreased and deburred before application of a rust-preventative primer. After the fan is completely assembled, a finish coat of paint shall be applied to the entire assembly. The fan shaft shall be coated with a petroleum-based rust protectant. Aluminum components shall be unpainted. ACCESSORIES — When specified, accessories such as inlet vanes, outlet dampers, companion inlet and outlet flanges, inlet bells, inlet boxes, shaft guards, and impeller and scroll liners shall be provided by Twin City Fan & Blower to maintain one source responsibility. FACTORY RUN TEST — All fans prior to shipment shall be completely assembled and test run as a unit at the specified operating speed or maximum RPM allowed for the particular construction type. Each impeller shall be statically and dynamically balanced in accordance with ANSI/AMCA 204-96 “Balance Quality and Vibration Levels for Fans” to Fan Application Category BV-3, Balance Quality Grade G6.3. Balance readings shall be taken by electronic type equipment in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy shall be available upon request. GUARANTEE — The manufacturer shall guarantee the workmanship and materials for its fans for at least one (1) year from startup or eighteen (18) months from shipment, whichever occurs first. www.tcf.com 77 INDUSTRIAL & COMMERCIAL FANS Centrifugal Fans | Utility Sets | Plenum & Plug Fans | Inline Centrifugal Fans Mixed Flow Fans | Tubeaxial & Vaneaxial Fans | Propeller Wall Fans | Propeller Roof Ventilators Centrifugal Roof & Wall Exhausters | Ceiling Ventilators | Gravity Ventilators | Duct Blowers Radial Bladed Fans | Radial Tip Fans | High Efficiency Industrial Fans | Pressure Blowers Laboratory Exhaust Fans | Filtered Supply Fans | Mancoolers | Fiberglass Fans | Custom Fans TWIN CITY FAN & BLOWER | WWW.TCF.COM A Twin City Fan Company .75MWG04/13 Twin City Fan Companies, Ltd. 5959 Trenton Lane N | Minneapolis, MN 55442 | Phone: 763-551-7600 | Fax: 763-551-7601
Similar documents
industrial fans - Twin City Fan and Blower
A large number of other appurtenances and accessories is available from Twin City Fan & Blower, including: • Belt guards – standard and OSHA type • Split housings • Shaft and bearing guards • C...
More informationdouble inlet centrifugal fan
Kruger Ventilation Industries certifies that the BDB series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA pub...
More informationsingle inlet centrifugal fan
series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the ...
More informationbackward curved high pressure fans
An inlet box is designed to minimize pressure drop and is recommended for applications where uniform flow is difficult to obtain due to limited space. Inlet boxes can be designed to be either detac...
More information