O`-SIALON THERMOCOUPLE PROTECTION TUBES (TCPT)
Transcription
O`-SIALON THERMOCOUPLE PROTECTION TUBES (TCPT)
O’-SIALON THERMOCOUPLE PROTECTION TUBES (TCPT) O’-SIALON / SILICON CARBIDE THERMOCOUPLES APPLICATIONS • Holding furnace dip well, launders and table tops • Bail-out crucibles • Gravity casting furnaces • Crucible holding furnaces • Low-pressure diecasting furnaces • Degassing crucibles BENEFITS • Good thermal shock properties • Non-wetting to aluminium • Less dross buildup at the metal line • High oxidation resistance • High chemical corrosion resistance O’-Sialon thermocouple protection tubes (TCPTs) are available in a range of standard lengths and diameters. Their aluminium non-wetting properties make them ideal for use in the aluminium industry. O’-Sialon TCPTs also have high levels of resistance towards oxidation, chemical corrosion and abrasion and have excellent thermal response properties. • High abrasion resistance SUPPLY OPTIONS O’-Sialon TCPTs can be supplied as standard ceramic tubes, or with a steel head and a fitted thermocouple. Contact your Pyrotek sales engineer or technical expert for information on complete TCPT assemblies. PHYSICAL PROPERTIES • Excellent response time • Narrow temperature control band for energy conservation Composition • SiC - 65% • O’-Sialon - 35% Bulk Density 2.6 g/cm3 (167.2 lb/ft3) Apparent Porosity 18.1% Modulus of Rupture 34 MPa (4931.3 psi) Coefficient of Expansion 4.4 x 10-6 /°C (2.44 x 10-6 /°F) Thermal Conductivity 8.9 W/m·K at 720°C (61.7 BTU·in/ft2·hr·°F at 1328°F) Continuous Maximum Temperature 1300°C (2372°F) O’-SIALON THERMOCOUPLE PROTECTION TUBES (TCPT) USE AND CLEANING • Before use, ensure the O’-Sialon TCPT is dry • If possible, preheat the TCPT to approximately 400°C (752°F) prior to use • The continuous maximum use temperature for the TCPT is 1300°C (2372°F) • O’-Sialon TCPT’s can be damaged by mechanical mishandling. To prevent damage, remove the TCPT from the furnace or crucible prior to skimming, stirring or using other tools in the metal bath. It is also important to avoid bumping or hitting the TCPT. • If possible, remove the TCPT when filling the crucible or furnace • Clean the TCPT while it is still hot (immediately after it is removed from the molten metal) using a wooden or calcium silicate tool AVAILABLE SIZES Small Diameter 17 mm (0.7 in) OD 9 mm (0.4 in) ID Series Part ID Length mm (in) OSITPT001 300 (11.8) OSITPT002 400 (15.7) OSITPT003 460 (18.1) OSITPT004 500 (19.7) OSITPT005 600 (23.6) OSITPT006 700 (27.6) OSITPT007 800 (31.5) OSITPT008 850 (33.5) OSITPT009 900 (35.4) OSITPT010 1200 (39.4) Medium Diameter 28 mm (1.1 in) OD 16 mm (0.6 in) ID Series Part ID Length mm (in) OSITPT022 400 (15.7) OSITPT023 460 (18.1) OSITPT024 500 (19.7) OSITPT025 600 (23.6) OSITPT026 700 (27.6) OSITPT026-1 750 (29.5) OSITPT027 800 (31.5) OSITPT028 850 (33.5) OSITPT029 900 (35.4) OSITPT030 1000 (39.4) OSITPT032 1200 (47.2) PYROTEK INC. Small Diameter Protection Tube Medium Diameter Protection Tube * * A 14.5 mm (0.6 in) groove is available as a special request. PAGE 2 O’-SIALON THERMOCOUPLE PROTECTION TUBES (TCPT) Large Diameter Protection Tube Large Diameter 45 mm (1.8 in) OD 25 mm (1 in) ID Series Part ID Length mm (in) OSITPT041 300 (11.8) OSITPT042 450 (17.7) OSITPT043 600 (23.6) OSITPT044 750 (29.5) OSITPT045 900 (35.4) OSITPT046 1050 (41.3) OSITPT047 1200 (47.2) PINNACLE THERMOCOUPLE PROTECTION TUBES Pyrotek’s Pinnacle thermocouple protection tubes are specially cast from O’-Sialon around a steel pipe enforcement for added strength and responsiveness. Pinnacle TCPTs are specifically designed for more sensitive temperature measurement, and to perform well in foundry and other high temperature applications where a balance of sensitivity and durability is required. With their long service life and O’-Sialon’s non-wetting properties, the robust, highly durable Pinnacle TCPTs are an excellent alternative to competitive tubes in temperature measurement, maintenance and product life. Threaded Length Part ID Length Part ID mm (in) 12.7 mm NPT 12.7 mm BSP (0.5 in) (0.5 in) mm (in) 19 mm NPT (0.75 in) 19 mm BSP (0.75 in) 152 (6) PPTP01 PPTP41 152 (6) PPTP21 PPTP61 254 (10) PPTP02 PPTP42 254 (10) PPTP22 PPTP62 305 (12) PPTP03 PPTP43 305 (12) PPTP23 PPTP63 457 (18) PPTP04 PPTP44 457 (18) PPTP24 PPTP64 559 (22) – PPTP40 559 (22) PPTP33 PPTP74 610 (24) PPTP05 PPTP45 610 (24) PPTP25 PPTP65 762 (30) PPTP06 PPTP46 762 (30) PPTP26 PPTP66 914 (36) PPTP07 PPTP47 914 (36) PPTP27 PPTP67 1067 (42) PPTP08 PPTP48 1067 (42) PPTP28 PPTP68 1219 (48) PPTP09 PPTP49 1219 (48) PPTP29 PPTP69 NPT (National Pipe Thread); BSP (British Standard Pipe) Note: The physical and chemical properties listed represent typical, average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. They are supplied as a technical service and are subject to change without notice. Contact Information: www.pyrotek.info/locations Pyrotek Corporate Office Telephone: +1 509-926-6212 www.pyrotek.info • email: [email protected] Product Type: 177 Commodity Code: 06002 NOV-15-E4-854