INSTALLATION INSTRUCTIONS MicroMetl For 1682/4682/5682 Series CAUTION! Always disconnect power before changing filters. ILL. #2 (7.5-12.5 Ton Only) CAUTION! Exhaust fan can cause severe injury. Always disconnect power before servicing. ILL. #1 INSTRUCTIONS 1. Disconnect the power to HVAC unit. 2. Remove the bottom panel from the HVAC unit and discard. Remove top filter access door and set aside for later use. (ILL. 1) 3. Uncrate the MicroMetl economizer 4. Remove the discharge air sensor from the economizer and install in the supply air chamber/duct. See wiring diagram and ILL. 6A. 5. Install the power exhaust supports for 200 and 300 styles. Use #12 x 1” tek screws to secure the supports to the base of unit (3 each). Use #8 x 1/2” tek screws to secure the supports to the unit’s economizer post (2 each). (ILL. 2 and 2A) 6. Slide the economizer into the return chamber, being sure not to pinch the harness. (ILL. 3) The rear flange of the economizer slides under the tab on the duct flanges (see rear flange detail). Secure economizer in place through side and bottom mating flange holes. 7. Connect the 12 pin plug/harness form the economizer into the 12 pin plug in the HVAC unit. HVAC unit’s filter door Unit Save Disc ard #12 Screws HVAC unit’s bottom panel. Remove and discard. Factory Provided supports (2) Flush to unit side ILL. #2A ILL. #3 Power Exhaust Support Unit HVAC unit corner post #8 Screw Power Exhaust Support Detail (Top View) Economizer Power Exhaust Specifications MicroMetl Part No. External Static in. wg. (2) 1682-0103 208/230V 3PH 4682-0103 460V 3PH 5682-0103 575V 3PH 1682-0203 208/230V 3PH 4682-0203 460V 3PH CFM performance 0.1 0.2 0.25 0.3 Full Load Amps(1) 2375 2125 2000 1850 1.1 3300 3000 2700 1.7 575V 3PH 1.1 6.6/6.6 460V 3PH MMC 1/2 1725 1 3.3/3.4 3800 208/230V 3PH 575V 3PH 1725 .65 1682-0303 5682-0303 HP Economizer clip on HVAC unit 2.3/2.2 5682-0203 4682-0303 Motor RPM 4200 4075 4000 3850 3.3 Economizer Slide economizer rear flange into tab Unit base 1725 2 Rear Flange Detail 2.4 3035 N. Shadeland Ave, Suite 300 Indianapolis, IN. 46226 MMC WEST 202 South 18th. St. Sparks, NV. 89431 Manufacturer reserves the right to discontinue, or change at any time, specifications, designs and prices without notice and without incurring obligations. Form No. 6668-1P Copyright MicroMetl Corporation 2003 All rights reserved 1 ILL. #6A (Side View) ILL. #5 Filter access door Mount discharge sensor here Water entrainment filter Power exhaust hood ECONOMIZER WIRING INSTRUCTIONS ILL. #6 Thermostat Connection Board 1 2 Red NOTE: There are (4) loose wires available in the HVAC unit. Connect the pink and violet wires to the discharge sensor. Do not use the brown and white wires 3 4 5 Plug harness installed in HVAC units Maintains mixed air temperature between 50O-56O. If using a fixed dry bulb, the orange wire will house a 620 ohm resistor. To compressor lockout “2” on HVAC unit (if 2 stage is used) Do not use Brw Connect the pink and violet wires to the discharge sensor. Do not use brown or white wires Compressor lockout switch on some models. Lockouts out compressors at 35O F (+/- 5O) Field wire if desired. Remove this jumper / resistor when using differential enthalpy. To compressor lockout “1” on HVAC unit MicroMetl discharge sensor (mount in blower compartment) Pink 4 If using differential enthalpy, setpoint should be at “D”. Enthalpy or adj. dry bulb Actuator Logic Exhaust Fan Set Point MicroMetl economizer harness / plug 620 OHM Resister + SR Minimum Position Setting DCV / CO2 maximum setpoint Red DCV / CO2 activation setpoint Power exhaust fan connection To optional CO2 sensor 2 EF EF1 AQ AQ1 Black N 24V HOT Enthalpy changeover setpoint 1 MicroMetl Integrated Economizers The purpose of an economizer is to use outdoor air for cooling, whenever possible, to reduce compressor operation. The fully open actuator cannot satisfy the space demand, mechanical cooling is sequenced on. During the unoccupied period, the actuator will override minimum position setting and drive fully closed. On a loss of power, the actuator will spring return fully closed. The economizer system initially responds to a signal from the cooling thermostat and functions as a true first stage for cooling, while providing maximum fuel economy. The economizer automatically locked out during the heating mode and holds the outdoor air damper at the minimum position settings. When in heating operation, or when outdoor air temperature or enthalpy conditions are high, economizer operation is locked out, and actuator os held at minimum position. During the occupied period, on a call for cooling, when outdoor air temperature or enthalpy conditions are low, the economizer actuator will proportion to maintain between 50O F and 56O F at thermistor discharge sensor. The staging relay is used when the first stage compressors must provide mechanical cooling when assisting the economizer. The staging relay can be omitted when the second stage compressors can be used to assist the economizer with mechanical cooling. If the mixed or discharge temperature is above 56O F, actuator will open to admit additional outdoor air until the temperature return to the 50O to 56O F range. If the mixed or discharge air temperature is below 50O F, the actuator will proportion closed, shutting the outdoor air damper until the temperature returns to the 50O to 56O F range. During the occupied period, the actuator will not close past the minimum position. If the fully open actuator cannot satisfy the space demand, mechanical cooling is sequenced on. 3 Component Description 6 1 4C 3 4A 2 4B 5 1. Damper actuator ...9901-1865 provides 24v modulating control of economizer damper, 25 in. lb. of torque, (Honeywell M7215A-1008) 4A. Entahlpy sensor ...9901-0018 senses and combines temperature and humidity of outdoor air. And also provides the signal to the economizer logic. (Honeywell C7400A used on 1008-0100) 2. Discharge sensor ...9901-0001 provides a signal (3000 Ohms at 25O C or 77O F) to the actuator during free cooling or economizer mode. The signal opens the economizer damper until the discharge temperature drops below 55O. At this time the signal causes the motor to modulate the damper and mix outside air with return air to maintain a 50O F to 56O F discharge temperature. 4B. Adjustable dry bulb ...9901-2251 senses temperature of outside air and provides signal to the economizer logic. (Honeywell C7660) 4C. Fixed dry bulb ...9901-0183 senses temperature of outside air. If below 70O setpoint, allows for free cooling. 3. Economizer logic ...9901-1805 accepts input from discharge sensor and outside air sensor. Analyzes input to control actuator modulation and economizer switching. Logic also houses minimum position adjustment, enthalpy or adjustable dry bulb adjustment, power exhaust control, and CO2 demand control ventilation adjustment. When used with optional differential sensor in the return air, the logic is capable of selecting the most economical air available for cooling. (Honeywell W7212-A1009) 5. Wire harness color coded and pre-wired to actuator and economizer logic. 6. Compressor lockout ...9901-0252 locks out compressor when temperature falls below 35OF (+/- 5OF). Shipped with economizer, but must be field wired, if desired. NOTES: 4 • Refer to the following pages for economizer logic operation instructions at the end of the power exhaust instructions in this manual. • If your economizer model includes the adjustable dry bulb sensor option, refer to the operation instruction at the back of this manual. Power Exhaust Wiring ILL. #8 POWER EXHAUST WIRING INSTRUCTIONS Disconnect box 8. Set the power exhaust in front of the economizer. Attach the two wire low voltage harness from the power exhaust to its mating plug in the economizer side flange. (ILL. 8A) Attach the high voltage cable from the power exhaust to its mating plug in the economizer. Route the high voltage cable to the HVAC unit controls. (ILL. 8) Coil and filter rack 9. Install the power exhaust hood assembly over the economizer. NOTE: The hood hooks over the top of the economizer (See Hood Latch Detail). Use #12 x 1” screws to secure the power exhaust hood to the unit’s economizer posts and power exhaust supports. 10. Locate the exhaust setpoint potentiometer on the economizer controller logic. Adjust the potentiometer so that the exhaust fan is activated when the outside air dampers are completely open. Wire path determined by installer 1682 power exhaust 11. Wire power exhaust per diagram on next page. Secure wires in place away from all moving parts. 12. First Calculate MCA New using the following formula: Economizer Installation hook on the hood MCA New = MCA unit only + MCA of Power Exhaust For example, using a 48HJD006 - 5 unit with MCA = 28.9 and MOCP = 35, with CRPWREXH030A00 power exhaust. MCA New = 28.9 amps + 1.6 amps = 30.5 amps. Rain Hood 13a. If MCA New < MOCP for the HVAC unit, you can tie the power wire to the HVAC contactor terminal strip. See Diagram 1, or follow 13b. If installed in unit, tap off terminal block capable of handling more than 1 wire. Hood Latch Detail **Route power exhaust wire to protect from damage (from impact, pull, sharp edges, hot surfaces, etc.) 13b. If MCA New > MOCP for the HVAC unit, you must run power wire for the power exhaust to an external disconnect. Make sure the disconnect is sized properly for the power from the power exhaust as well as the HVAC unit. ILL. #8A *Refer to Diagram 1 on Page 6 for more information. 13. If using modulating power exhaust option, refer to modulating options page. IMPORTANT NOTE: Follow all local codes when wiring system. CAUTION! Outside air blades must be completely open before exhaust fan is activated. Adjust end switch accordingly. CAUTION! Exhaust fan can cause severe injury. Always disconnect power before servicing. 5 13a 13b DIAGRAM 1 NOTES: 1. 575 V transformer No. HT01AH859 is ordered separately from power exhaust. 2. Economizer actuator and controller are shipped with the economizer - not with power exhaust. 3. Connections from End Switch plug to the economizer controller are made by installer. 4. If a single power source is to be used, size wire to include power exhaust MCA and MOCP. Check MCA and MOCP When power exhaust is powered through the unit. Determine the new MCA including the power exhaust using the following formula: MCA New = MCA unit only + MCA of Power Exhaust For example, using a 48HJD006 - 5 unit with MCA = 28.9 and MOCP = 35, with CRPWREXH030A00 power exhaust. MCA New = 28.9 amps + 1.6 amps = 30.5 amps. If the new MCA does not go over the MOCP published, then MOCP would not change. The MOCP in this example is 35 amps, the MCA New is below 35, therefore the MOCP is OK. If “MCA New” is larger than the published MOCP, raise the MOCP to the next larger size. For separate power, the MOCP for the power exhaust will be 15 amps per NEC. 6 Power Exhaust Wiring ILL. #10 24-Volt Transformer Color Code CONTROL BOX IN POWER EXHAUST Common Yellow Yellow Yellow Black Power Red - 208V Orange - 230V Black - 460V Grey - 575V NOTE: 1) Wire transformer according to it’s wiring description and the customer specifications. 2) Transformer, contactor and fuses are to be mounted in a NEMA type electrical box. 3) Use 14 AWG or larger conductor for wiring. 4) Follow all local codes. **Refer to Diagram 1. Use the formula on page 6 and 7 to determine electrical configuration. **Wire color can be substituted to Red, White, Black, and Green between the motors and power exhaust terminal block. PLUG #2 Wiring Diagram For 102S-0100 Two Speed Power Exhaust Controller Low Speed ELECTRICAL BOX R1 Low speed motor 1 LOW SPEED 7 Mounted on economizer actuator BLUE YELLOW BLACK BLUE YELLOW BLACK BLUE YELLOW BLACK Power Red - 208V Orange - 230V Black - 460V Grey - 575V T5 T6 motor COMMON Common Yellow Yellow Yellow Black NOTE: 1) Wire transformer according to it’s wiring description and the customer specifications. **Refer to Diagram 1. Use the formula on page 6 and 7 to 2) Transformer, contactor and determine electrical configuration fuses are to be mounted in a 25 ft. SE0W/ NEMA type electrical box. S0W Power 3) Use 14 AWG or larger Cord conductor for wiring. High speed 4) Follow all local codes. GROUND ORANGE BLUE YELLOW BLACK POWER GROUND YELLOW YELLOW T4 24-Volt Transformer Color Code A B R1 9 6 ORANGE High Speed 7 T1 T2 T3 Mounted on economizer actuator **Wire color can be substituted to Red, White, Black, and Green between the motors and power exhaust terminal block. Modulating Blower Power Exhaust (Option) Blower Modulation Installation Instructions (use this page only if the modulating exhaust option has been ordered) The 1682/4682/5682-0103-M*930, and 4682/1682-0303-M*930 Power Exhaust contains a motor controller that varies the blower speed in order to maintain an acceptable room pressure. The power exhaust is equipped with a pressure sensing transducer that compares room pressure to atmospheric. This transducer sends a signal to the motor controller which varies the motor voltage in order to provide pressure relief. Installation Instructions: 1. Install 1/8” i.d. or 3/16” i.d. pressure tubing to the room pressure sensor located within the building space. 2. Power exhaust is factory set at these CFM at .25”: 1682/4682/5682-0103 1682/4682/5682-0203 1682/4682/5682-0303 Note: If the power exhaust will not engage, check motor controller for fault light. If fault light is on, reverse phase sequence at the power cord (not in the motor box) 2000 CFM 3000 CFM 4000 CFM 3. Place the HVAC unit in continuous operation mode. 4. In order to determine system operation conditions, adjust the economizer minimum position to 100% outside air. At this time measure the room static pressure differential to insure that the space is balanced to an acceptable pressure difference (i.e. less than 0.05” w.g.). If the room pressure i above 0.05” w.g., increase the blower speed by adjusting the motor pulley. 5. Measure the power exhaust line amperage at the disconnect box. Compare the amperage to the table below to insure that the motor will not overload during modulation. 6. The amp draw must not exceed the values listed below. 7. If the amperage is too high, the blower must be lowed down by adjusting the pulleys. Repeat steps 3 to 6. If the room pressure is excessive at this point, call MicroMetl for further assistance. **If installed in unit, tap off terminal block capable for handling more than 1 wire. Factory installed tubing to atmospheric pressure port ILL. #13 Factory installed tubing to room pressure sensor 25 ft of tubing factory supplied Factory installed atmospheric pressure port. Covered by hood Transducer factory installed Return air duct. Field supplied Tubing for room pressure field installed Maximum Amp Draw Room pressure sensing port. Mount to ceiling or wall. Co-axial cable cover field provided. 8 HP 208 V 230 V 460 V 575 V 3-6 ton 1/2 2.3 2.2 1.1 .65 7 1/2-8 1/2 ton 1 3.3 3.4 1.7 1.1 10-12 1/2 ton 2 6.6 6.6 3.3 2.4 For Modulating Power Exhaust Only TUNING THE PI CONTROL Once the PI is set up correctly, it needs to be tuned in order to maintain the process setpoint. First, set the Integral Gain to zero, and increase the Proportional Gain (parameter 64) until the system becomes unstable, then lower the gain until the system stabilizes the system. If only Proportional Gain is used, and the system is operating in a steady-state condition (setpoint is fixed and process variable has settled to a fixed value), there will always be a certain about of error in the system. This is called the steady-state error. Integral Gain (Parameter 65) is used to force the steadystat error to zero by increasing the output speed command with respect to time. Over time, the error will be forced to zero because the Integral term will continue to change the speed command , even after the Proportional term reaches steady state and no longer affects the speed command. The Integral Gain affects the rate of rise of the output speed command from the Integral term. Small amounts of Integral Gain can cause large changes in PI performance, so car must be taken when adjusting Integral Gain. Too much Integral Gain will result in overshoots, especially if large step changes in error occur. The other parameter setting that affects the response of the PI control is Parameter 66 - PI ACC. This sets the acceleration (and deceleration) rate of the setpoint reference into the PI unit. When the setpoint changes, this function will “filter” the input to the PI unit by ramping the setpoint reference from the pervious value to the new value. This will help prevent overshoots that can setpoint, resulting in smoother operation. If PI ACC is set to 0.0 seconds, it is effectively disabled. Parameter 55 is also frequently used. P55 displays the level of the 0-10 VDC analog input signal (in percent) at TB-5. 9 Modulating Power Exhaust Motor Connections Low Voltage HIGH 460 V LOW 230 V 200-240 V L1 L2 G L3 High Voltage **Wire color can be substituted to Red, White, Black, and Green between the motors and VFD. HIGH 460 V LOW 230 V 460 V G L1 L2 L3 575 V **Refer to Diagram 1. Use the formula on page 6 and 7 to determine electrical configuration. L1 L2 G Power Exhaust Static Data X denotes factory settings 10 L3 Power Exhaust Static Data X denotes factory settings X denotes factory settings 11 W7212, W7213, W7214 Economizer Logic Modules FOR VENTILATION CONTROL PRODUCT DATA FEATURES • Operates from thermostat and DCV sensor to provide a totally integrated control system. • Solid state control package provides accurate, reliable and stable control. • Mounts on M7215 Motor or ductwork. • Control can be tempered by DCV and fan cycling. • Used with Honeywell actuators. • Combines minimum and DCV maximum damper position potentiometers with compressor staging. • Solid state enthalpy or dry bulb changeover control. • Terminals included for switching between Occupied and Unoccupied operation. • Terminals included for connecting optional S963B1128 Remote Potentiometer for remote minimum damper position control. • LED indicates when free cooling is available. APPLICATION W7212, W7213, and W7214 Economizer Logic Modules are used with C7232 Demand Control Ventilation (DCV) Sensors, and solid state C7400 Enthalpy Sensors or C7660 Dry Bulb Temperature Sensors. All models proportion outdoor and return air dampers for control of free cooling in commercial HVAC equipment. • LED indicates when module is in DCV mode. • LED indicates when exhaust fan contact is closed. • W7213 is used with heat pump B terminal. • W7214 is used with heat pump O terminal. Contents Application ........................................................................ 1 Features ........................................................................... 1 Specifications ................................................................... 2 Ordering Information ........................................................ 2 Installation ........................................................................ 3 Operation .......................................................................... 5 Settings and Adjustments ................................................. 7 Checkout and Troubleshooting ......................................... 17 63-2596-05 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES SPECIFICATIONS Models: W7212A, W7213A, W7214A Logic Modules: for use with any Honeywell 2-10 Vdc actuator; includes DCV input; adjustable exhaust fan setpoint. NOTES: — — All models include a minimum damper position potentiometer, and setpoints for: enthalpy or dry-bulb, occupied/unoccupied control, DCV operation, and DCV maximum. Occupied/Unoccupied overrides minimum damper position setting when building is unoccupied. Dimensions: See Fig. 1. Electrical Ratings: Input Voltage: 24 Vac ±20%; 50/60 Hz (Class 2). Nominal Power Consumption (at 24 Vac, 60 Hz): 11.5 VA. Relay Contact Rating at 30 Vac (maximum power from class 2 input only): 1.5A run, 3.5A inrush. Approvals: Underwriters Laboratories Inc.: UL873 listed. Flammability Rating: UL94-5VB. Plenum Rated. CE. C-tick. Accessories: 4074EJM Bag Assembly. Consists of: Checkout jumper, 620 ohm, 1.2K ohm, 5.6K ohm, and 6.8K ohm checkout resistors. C7046A Discharge Air Temperature Sensor. C7150B Mixed Air Temperature Sensor. C7232A,B Carbon Dioxide Sensors. C7400 Solid State Enthalpy Sensor. C7660 Dry Bulb Temperature Sensor. S963B1128 Remote Potentiometer to provide remote control of damper minimum position. ST6008 Energy Management Timer for occupied/unoccupied control. IMPORTANT All inputs and outputs must be 24 Vac Class 2. 4-3/8 (112) Ambient Ratings: Temperature: -40°F to +149°F (-40°C to +65°C). Humidity: 5 to 95 percent RH (noncondensing). 1-5/8 (41) Inputs: Enthalpy (C7400): 2-wire (18,20,22 AWG) connection. Dry Bulb Temperature (C7660): 2-wire (18,20,22 AWG) connection. Discharge Air (C7046): 2-wire (18,20,22 AWG) connection. Mixed Air (C7150): 2-wire (18,20,22 AWG) connection. DCV Sensor (C7232): 0/2-10 Vdc control signal; 100K ohm input impedance. 2-1/16 (53) 1-15/16 (49) 4-1/8 (104) Outputs: Actuator Signal: 2-10 Vdc. Minimum Actuator Impedance: 1K ohm. Exhaust Fan: Contact closure. 24 Vac Out: 25 VA maximum. 1/8 (4) 2-5/8 (66) M20578A Fig. 1. Logic module dimensions in in. (mm). ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 63-2596—05 2 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES INSTALLATION When Installing this Product... 1. 2. 3. 4. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. Installer must be a trained, experienced service technician. After installation is complete, check out product operation as provided in these instructions. Location and Mounting The logic modules mount on an M7215 or a sheet metal duct or panel. When planning the installation, allow enough clearance for maintenance and service (see Fig. 1 for dimensions). Mount device in a location protected from rain, snow, and direct sunlight. Secure device to sheet metal using the two supplied mounting screws, see Fig. 3. CAUTION Equipment Damage Hazard. Mounting screws longer than 5/8 in. can damage internal motor components. When mounting the module to an M7215 use only the included #6 5/8 in. thread-forming screw. NOTE: See Fig. 4 for representative locations of connected system devices. M7215 DAMPER MOTOR M20601 Fig. 3. Mounting the module on sheet metal. C7400 Enthalpy Sensor and C7660 Dry Bulb Temperature Sensor W7212, W7213, W7214 Logic Modules accept signals from either the C7400 Enthalpy Sensor or the C7660 Dry Bulb Temperature Sensor. The wiring is the same for either sensor. IMPORTANT When using differential sensing, both sensors must be of the same type (enthalpy or dry bulb). OUTDOOR AIR SENSING 1. Mount sensor in any orientation exposing it to freely circulating air while protecting it from rain, snow, and direct sunlight. 2. Connect it to the SO and SO+ terminals of the device. RETURN AIR SENSING 1. Ensure differential enthalpy control has a second enthalpy sensor in the return air duct. 2. Connect this sensor to the SR and SR+ terminals. 3. Ensure sensor is mounted in the return air duct for proper operation. ECONOMIZER LOGIC MODULE Demand Control Ventilation The DCV can be any sensor that provides a 0/2-10 Vdc output. The DCV modulates the outdoor damper to provide ventilation based on occupancy. The designer determines contaminants to monitor, selects appropriate sensor, determines the sensor threshold, and adjusts the DCV potentiometer accordingly. The DCV LED lights when the DCV signal is above setpoint. EXAMPLE: 5/8 INCH SCREW INCLUDED WITH LOGIC MODULE. M20717B Fig. 2. Direct mounting of module. 3 CO2 sensor with 0 to 10 Vdc output range 0 to 2000 ppm. Zero (0) Vdc is equal to 0 ppm, 10 Vdc is equal to 2000 ppm, threshold is determined to be 800 ppm. DCV potentiometer to be set at 4 Vdc. 63-2596—05 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES Mount the sensor according to the manufacturer specifications. If not available, use the following guidelines: 1. Mount sensor in an area with unobstructed air circulation. 2. 3. Connect it to the AQ and AQ1 terminals of the W7212 (see Wiring section for details). Adjust the DCV potentiometer setpoint to correspond to DCV voltage output at the threshold. SPACE THERMOSTAT DISCHARGE AIR SENSOR C7046A DIRECT EXPANSION COIL 2 C7232 C7150B W7212, W7213, W7214 DISCHARGE AIR 2 1 MIXED AIR SENSOR INDOOR FAN DCV SENSOR ENTHALPY SENSOR C7400 HONEYWELL ACTUATOR OUTDOOR AIR 1 C7400 1 2 ENTHALPY SENSOR FOR DIFFERENTIAL ENTHALPY, THE TWO C7400 ENTHALPY SENSORS ARE CONNECTED TO THE ECONOMIZER LOGIC MODULE—ONE IS MOUNTED IN RETURN AIR, AND THE OTHER IS MOUNTED IN OUTDOOR AIR. EXHAUST FAN USE EITHER MIXED AIR SENSOR OR DISCHARGE AIR SENSOR, NOT BOTH. RETURN AIR EXHAUST AIR M19547B Fig. 4. Representative locations of connected economizer system devices. Wiring connection to the logic module O/B terminal. This terminal alerts the logic module as to when the system operates in cooling (the only time the economizer is used). During heating applications with defrost make sure to break the connection to the economizer using an isolation relay. CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. W7213 (CHANGEOVER TERMINAL B) Connect the B terminal according to the following details: — 24V power to B: System is in heating mode. — No power to B: System is in cooling mode. IMPORTANT 1. All wiring must comply with applicable local codes, ordinances and regulations. 2. Refer to Table 1 for a list of the wiring diagrams and corresponding Figure numbers in this document. 3. All device inputs and outputs must be 24 Vac Class 2. 4. Ensure proper polarity of sensor connections. Incorrect polarity negates the sensor signal. Optional Applications Heat Pump Changeover (W7213, W7214 only) In heat pump applications, the controller must have control of the changeover valve. To provide the logic module with the information necessary for proper information, there must be a 63-2596—05 4 W7214 (CHANGEOVER TERMINAL O) Connect the O terminal according to the following details: — 24V power to O: System is in cooling mode. — No power to O: System is in heating mode. Remote Minimum Position Control Remote control of outdoor air dampers is desirable when requiring temporary additional ventilation. The addition of a S963B1128 Remote Potentiometer allows occupants to open or close the dampers beyond minimum position for modified ventilation. Connect the potentiometer as shown in Fig. 5. W7212, W7213, W7214 ECONOMIZER LOGIC MODULES IMPORTANT — The minimum position signal takes priority over the DCV maximum position signal. With DCV maximum set below the minimum, the logic module signals the actuator to maintain the minimum position. — Freeze protection logic takes priority over all signals. For details, see the notes in the Adjusting Minimum and Maximum Positions section. NOTE: For additional wiring applications, refer to the Design and Application Guide for Honeywell Economizers (form 63-8594). Table 1. Applicable Wiring Diagrams. Actuator Honeywell MS7XXX Honeywell M7215 n/a Honeywell Series 72 Enthalpy Changeover Single Single or Differential Comments Single-stage cooling system. Two-stage cooling system. Single n/a Single or Differential Two-stage heat pump system. Direct mount Logic Module to Motor. S963 remote damper control. Honeywell Series 72. OPERATION The purpose of the economizer is to use outdoor air for cooling, whenever possible, to reduce compressor operation. Power at the N terminal determines the Occupied/Unoccupied setting: — W7212: • 24 Vac (Occupied). • No power (Unoccupied). — W7213,W7214: • 24 Vac (Unoccupied). • No power (Occupied). — See Fig. 8 through 14 for controller hookup. NOTE: When module is operating in Occupied mode, the minimum position is defined by the potentiometer. When the module is operating in Unoccupied mode, and there is no call for cooling, the damper drives fully closed. When wired as shown in Fig. 8 through 14, the logic module responds to the cooling thermostat signal. The system uses C7400 Solid State Enthalpy Changeover Sensor(s) or C7660 Dry Bulb Temperature Sensor(s). The C7400 responds to both dry bulb temperature and humidity, allowing use of outdoor air 5 Figure 11 12 12 14 8 5 13 Economizer W7212 W7213, W7214 W7212 W7212 at higher temperatures for free cooling when humidity is low. The C7660 responds only to dry bulb temperature; use only in dry, arid climates and only in single dry bulb changeover. Do not use the C7660 in differential dry bulb applications. The logic module functions as a true first stage of cooling providing maximum energy economy during the cooling cycle. It automatically locks out free cooling during heating; holding the outdoor air damper at the minimum position setting. The logic module can operate as either a basic free cooling controller, or it can incorporate additional functions. Table 2 details the input/output (I/O) logic of the module. S963B1128 REMOTE POTENTIOMETER CW CLOSE W R MINIMUM POSITION ADJUSTMENT P1 B P CW ECONOMIZER M20603A Fig. 5. S963B1128 Remote Potentiometer used with logic module for remote damper control. 63-2596—05 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES Table 2. W7212 Economizer I/O Logic. INPUTS Enthalpy OUTPUTS a Demand Control Outdoor Ventilation (DCV) Below set High (DCV LED Off) (Free Cooling LED Off) Low (Free Cooling LED On) Above set (DCV LED On) N Terminalb Compressor Stage Return Y1 Y2 1 Low On On On On Off On Off Off Off High On On On On Off Off High (Free Cooling LED Off) Low Low (Free Cooling LED On) High Off On On Off On On Off Off On Off Off On Off Off Off On On Off On Off Off Occupiedb Unoccupiedb Stage 2 Damper On Minimum position Closed Off Off Off Modulatingc Modulatingc (between min. position (between closed and Off and full-open) full-open) Off Minimum position Closed On Modulatingd Modulatingd (between min. position (between closed and Off and DCV maximum) DCV maximum) Off Off Off Off Modulatinge Modulatingf a For single enthalpy control, the module compares outdoor enthalpy to the ABCD setpoint. Power at N terminal determines Occupied/Unoccupied setting: • W7212: 24 Vac (Occupied), no power (Unoccupied). • W7213,W7214: No power (Occupied), 24 Vac (Unoccupied). c Modulation is based on the mixed air sensor signal. d Modulation is based on the DCV signal. e Modulation is based on the greater of DCV and mixed air sensor signals, between minimum position and either maximum position (DCV) or fully open (mixed air signal). f Modulation is based on the greater of DCV and mixed air sensor signals, between closed and either maximum position (DCV) or fully open (mixed air signal). b NOTES: — — — 63-2596—05 DCV and Free Cooling have setpoints and LED indications. For models with a B terminal (W7213): No power to B: cooling mode, free cool enabled. Module follows logic detailed above. 24V power to B: heating mode, free cool disabled. Actuator drives to minimum position (closed when Unoccupied). For models with an O terminal (W7214): 24V power to O: cooling mode, free cool enabled. Module follows logic detailed above. No power to O: heating mode, free cool disabled. Actuator drives to minimum position (closed when Unoccupied). 6 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES SETTINGS AND ADJUSTMENTS NOTES: — CAUTION — Equipment Damage Hazard. Excessive force can damage potentiometer controls. Use a small screwdriver when adjusting enthalpy changeover and minimum damper position controls. Potentiometers with screwdriver adjustment slots, located on device face, provide adjustments for several parameters (see Fig. 6 for locations on device): — DCV setpoint. — Minimum damper position. — DCV maximum damper position. — Enthalpy changeover. — Exhaust setpoint. EXHAUST FAN SETPOINT LED LIGHTS WHEN EXHAUST CONTACT IS MADE MINIMUM DAMPER POSITION SETTING MAXIMUM DAMPER DEMAND CONTROL VENTILATION SETPOINT LED LIGHTS WHEN DEMAND CONTROL VENTILAION INPUT IS ABOVE SETPOINT N1 N EXH Set 10V EXH P1 P Min Pos T1 2V AQ1 2V SO SR+ SR LED LIGHTS WHEN OUTDOOR AIR IS SUITABLE FOR FREE COOLING DCV Max 10V For detailed assistance in minimum position selection reference the Economizer Application Guide (form 63-8594) Ventilation section. The following provides basic guidelines for minimum position selection and adjustment: IMPORTANT • Adjust the minimum position potentiometer to allow the minimum amount of outdoor air for building effluents, as required by local codes, to enter the building. • This procedure requires use of a quality thermometer capable of reading to 0.5°F [0.25°C]. 1. DCV AQ Minimum Position Adjustment NOTE: Make minimum position adjustments with at least a 10°F [6°C] temperature difference between outdoor and return air. Open T SO+ DEMAND CONTROL VENTILAION SETPOINT 2V DCV Set 10V 2. 3. 4. Free Cool B C A D ENTHALPY CHANGEOVER SETPOINT When the mixed air sensor takes control based on an increased requirement for cooling, it overrides the DCV maximum position potentiometer and can drive the damper full-open. If the mixed air temperature drops to 45°F, the mixed air sensor overrides the DCV and closes the damper to protect from freezing the hot or chilled water coils. Control returns to normal once the mixed air temperature rises to 48°F. Some models of the W7212 close the damper fully and others close the damper to minimum position position. 5. 6. M20604 Fig. 6. Potentiometer and LED locations (W7212 shown). Demand Control Ventilation Setpoint Calculate the appropriate mixed air temperature, see Equation 1. Disconnect mixed air sensor from terminals T and T1. Place a jumper across terminals T and T1. Ensure that either the factory-installed jumper is in place across terminals P and P1 or, if remote damper position is required, that it is wired according to Fig. 5 and turned fully clockwise. Connect 24 Vac across terminals TR and TR1. Carefully adjust the potentiometer on the face of the device with a small screwdriver until the mixed air temperature reaches the calculated value. NOTE: Ensure that the sensed air is well mixed. The logic module modulates the outdoor damper to provide ventilation based on the 0/2-10 Vdc DCV. With no cooling signal, the DCV overrides the outdoor air damper when ventilation requires additional outdoor air. 7. Adjusting Minimum and Maximum Positions The minimum position potentiometer maintains the minimum outdoor air flow into the building during the occupied period. The minimum position allows for the building effluents. The DCV maximum position potentiometer allows the installer to limit the amount of outdoor air flow into the building when the DCV overrides the mixed air sensor and allows the proper ventilation based on occupancy. Setting the DCV maximum position of the damper prevents the introduction of large amounts of hot or cold air into the space by preventing the dampers from opening 100%. Set the DCV maximum position at the maximum design occupancy. IMPORTANT With the DCV maximum position set below the minimum position, the minimum position overrides the maximum position (negating most DCV functions of the logic module, as the damper cannot move). 7 If all minimum and maximum position adjustments are complete, remove the T-T1 jumper and reconnect the mixed air sensor. Equation 1.Formula to aid minimum position adjustment. T O OA + T R RA = T M Where: TO = Outdoor air temperature OA = Percent of outdoor air TR = Return air temperature RA = Percent of return air TM = Resulting mixed air temperature NOTE: The following sample calculation uses only Fahrenheit temperature. EXAMPLE: Assume local codes require 10% outdoor air during occupied conditions, outdoor air is 60°F and return air is 75°F. Under these conditions, what is the temperature of the mixed air? 0.1 60°F + 0.9 75°F = 6.0°F + 67.5°F = 73.5°F 63-2596—05 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES Mixed air will be 73.5°F when OA is 60°F and RA is 75°F with 10 percent outdoor air entering the building. NOTE: Turn the enthalpy setpoint potentiometer fully clockwise to the D setting. DCV Maximum Position Adjustment The logic module selects the lower enthalpy air (return or outdoor) for cooling. For example, when outdoor air has lower enthalpy than return air, the module calls to open the outdoor air damper to bring in outdoor air for free cooling. 1. 2. 3. 4. 5. Disconnect mixed air sensor from terminals T and T1 and short terminals T and T1. Connect a jumper between terminals AQ and SO+. Connect 24 Vac across terminals TR and TR1. Adjust the potentiometer on the face of the device with a screwdriver for desired maximum position. If all minimum and maximum position adjustments are complete, remove the T-T1 jumper and reconnect the mixed air sensor. Enthalpy Changeover Setpoint The exhaust setpoint determines when the exhaust fan runs based on damper position. When the exhaust fan call is made, the module provides a 60 ±30 second delay before exhaust fan activation. This delay allows the damper to reach the appropriate position to avoid unnecessary fan overload. NOTES: — Outdoor Enthalpy Changeover Setpoint (Single Enthalpy) The outdoor enthalpy changeover setpoint returns the outdoor air damper to minimum position when enthalpy rises above its setpoint. Enthalpy setpoint scale markings, located in the device, are A, B, C, and D. See Fig. 7 for the corresponding control point. The factory-installed 620-ohm jumper must be in place across terminals SR and SR+. Temperature and humidity points to the left of the selected curve will allow the dampers to open for free cooling. Differential Enthalpy Changeover Setting Differential enthalpy control uses two C7400 Enthalpy Sensors connected to one logic module. The logic module compares outdoor air to return air. 63-2596—05 Exhaust Setpoint 8 — EF and EF1 are 24V dry contacts only. An external line voltage contactor is required to operate the exhaust fan. When the exhaust fan is deactivated the EF and EF1 contacts open immediately. Adjustable Exhaust Setpoint These logic modules have an adjustable exhaust setpoint. This potentiometer allows the installer to adjust the damper position at which the EF and EF1 exhaust fan contacts are made. NOTE: The 60 ±30 second delay allows the outdoor damper to reach the exhaust setpoint prior to the EF and EF1 contacts being made. W7212, W7213, W7214 ECONOMIZER LOGIC MODULES 46 85 90 95 100 105 110 (29) (32) (35) (38) (41) (43) 44 CONTROL CONTROL POINT APPROX. °F (°C) CURVE AT 50% RH 73 (23) A 70 (21) B 67 (19) C 63 (17) D IDI UM 32 PE R 30 U 70 (21) 16 18 55 (13) B 12 14 50 (10) 40 (4) 45 (7) 50 A 30 20 60 (16) 40 22 60 70 80 26 65 (18) 24 EN T HA 10 0 90 28 LP Y— BT RE LA TIV EH 36 75 (24) PO UN 34 D D RY TY 38 AI R (% ) 40 42 80 (27) C 20 D 10 35 (2) B A D C 35 (2) 40 (4) 45 (7) 50 (10) 1 55 60 65 70 75 80 85 90 95 100 105 110 (13) (16) (18) (21) (24) (27) (29) (32) (35) (38) (41) (43) APPROXIMATE DRY BULB TEMPERATURE— °F (°C) 1 HIGH LIMIT CURVE FOR W7210D, W7212, W7213, W7214, W7340B. M11160C Fig. 7. W7212, W7213, W7214 performance characteristics for enthalpy changeover settings. 9 63-2596—05 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES TR TR1 24 Vac HOT 24 Vac COM N1 N MINIMUM POSITION ADJUSTMENT P1 C7150B MIXED AIR OR C7046A DISCHARGE AIR SENSOR P 24 VAC HOT T1 + – T 2 AQ1 – 2-10 VDC CONTROL SIGNAL INPUT 1 0/2-10 VDC INDOOR AIR SENSOR 24 VAC COM 5 AQ + SO+ 3 4 EF EF1 SO SR+ M7215 SR C7400 OUTDOOR AIR ENTHALPY SENSOR + S W7212 3 5 620 OHM RESISTOR L1 (HOT) L2 EXHAUST FAN Y1 C Y2 Y1 COOL 1 W2 Y2 COOL 2 W2 HEAT 2 W1 HEAT 1 W1 A2 A1 4 A2 G A1 RH G FAN RC R X HVAC EQUIPMENT TERMINAL STRIP T7300/Q7300 THERMOSTAT 1 L1 (HOT) 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 ENSURE THAT TRANSFORMER IS SIZED TO HANDLE THE EXTRA LOAD OF THE ECONOMIZER AND ACTUATOR. USE THE SAME TRANSFORMER FOR T7300 AND ECONOMIZER. 3 FACTORY INSTALLED 620 OHM, 1 WATT, 5% RESISTOR SHOULD NOT BE REMOVED. DIFFERENTIAL ENTHALPY NOT RECOMMENDED FOR USE WITH SINGLE-STAGE COOLING SYSTEMS OR SINGLE-STAGE COOLING THERMOSTATS. 4 T7300 TERMINALS A1 AND A2 ARE CONNECTED WHEN THERMOSTAT IS IN THE OCCUPIED MODE. 5 EF AND EF1 ARE DRY CONTACTS IN THE LOGIC MODULE. Fig. 8. W7212 used with M7215 Damper Motor and T7300 Thermostat. 63-2596—05 2 L2 10 M20716D W7212, W7213, W7214 ECONOMIZER LOGIC MODULES TR TR1 24 Vac HOT 24 Vac COM N1 N MINIMUM POSITION ADJUSTMENT P1 C7150B MIXED AIR OR C7046A DISCHARGE AIR SENSOR P 24 VAC HOT T1 + – T 2 AQ1 – 2-10 VDC CONTROL SIGNAL INPUT 1 0/2-10 VDC INDOOR AIR SENSOR 24 VAC COM 5 AQ + SO+ 3 4 EF EF1 SO SR+ M7215 SR C7400 OUTDOOR AIR ENTHALPY SENSOR + S W7212 4 5 620 OHM RESISTOR L1 (HOT) L2 EXHAUST FAN Y1 C Y2 Y1 COOL 1 W2 Y2 COOL 2 W2 HEAT 2 W1 HEAT 1 W1 AUX 3 A2 G RH G FAN RC R X HVAC EQUIPMENT TERMINAL STRIP T7350 THERMOSTAT 2 L2 1 L1 (HOT) 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 ENSURE THAT TRANSFORMER IS SIZED TO HANDLE THE EXTRA LOAD OF THE ECONOMIZER AND ACTUATOR. THE SAME TRANSFORMER CAN BE USED FOR THE THERMOSTAT AND ACTUATOR. 3 IF SEPARATE HEATING AND COOLING TRANSFORMERS ARE USED, REMOVE JUMPER AT THERMOSTAT. T7350 - TERMINAL “AUX” IS POWERED BY THE HEATING TRANSFORMER (RH). IF POWERING THE ECONOMIZER TERMINAL “N” WITH THE THERMOSTAT TERMINAL “AUX”, BE SURE THE ECONOMIZER IS POWERED BY THE SAME TRANSFORMER AS TERMINAL “AUX”. IF NOT, USE AN ISOLATION RELAY TO POWER “N”. 4 FACTORY INSTALLED 620 OHM, 1 WATT, 5% RESISTOR SHOULD NOT BE REMOVED. DIFFERENTIAL ENTHALPY NOT RECOMMENDED FOR USE WITH SINGLE-STAGE COOLING SYSTEMS OR SINGLE-STAGE COOLING THERMOSTATS. 5 EF AND EF1 ARE DRY CONTACTS IN THE LOGIC MODULE. M13657 Fig. 9. W7212 used with M7215 Damper Motor and T7350 Thermostat. 11 63-2596—05 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES TR TR1 24 Vac HOT 24 Vac COM N1 N MINIMUM POSITION ADJUSTMENT P1 C7150B MIXED AIR OR C7046A DISCHARGE AIR SENSOR P 24 VAC HOT T1 + – T 2 AQ1 – 2-10 VDC CONTROL SIGNAL INPUT 1 0/2-10 VDC INDOOR AIR SENSOR 24 VAC COM 5 AQ + SO+ 3 4 EF EF1 SO SR+ M7215 SR C7400 OUTDOOR AIR ENTHALPY SENSOR + S W7212 4 5 620 OHM RESISTOR L1 (HOT) L2 EXHAUST FAN Y1 C Y2 Y1 COOL 1 W2 Y2 COOL 2 W2 HEAT 2 W1 HEAT 1 W1 A 3 A G R G FAN RC R X HVAC EQUIPMENT TERMINAL STRIP TB7220 OR TB8220 THERMOSTAT 1 L1 (HOT) 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 ENSURE THAT TRANSFORMER IS SIZED TO HANDLE THE EXTRA LOAD OF THE ECONOMIZER AND ACTUATOR. THE SAME TRANSFORMER CAN BE USED FOR THE THERMOSTAT AND ACTUATOR. 3 IF SEPARATE HEATING AND COOLING TRANSFORMERS ARE USED, REMOVE JUMPER AT THERMOSTAT. TB7220 - TERMINAL “A” IS POWERED BY THE COOLING TRANSFORMER (RC). TB8220 - TERMINAL “A” IS POWERED BY THE HEATING TRANSFORMER (R). IF POWERING THE ECONOMIZER TERMINAL “N” WITH THE THERMOSTAT TERMINAL “A”, BE SURE THE ECONOMIZER IS POWERED BY THE SAME TRANSFORMER AS TERMINAL “A”. IF NOT, USE AN ISOLATION RELAY TO POWER “N”. 4 FACTORY INSTALLED 620 OHM, 1 WATT, 5% RESISTOR SHOULD NOT BE REMOVED. DIFFERENTIAL ENTHALPY NOT RECOMMENDED FOR USE WITH SINGLE-STAGE COOLING SYSTEMS OR SINGLE-STAGE COOLING THERMOSTATS. M13658 5 EF AND EF1 ARE DRY CONTACTS IN THE LOGIC MODULE. Fig. 10. W7212 used with M7215 Damper Motor and TB7220 or TB8220 Thermostats. 63-2596—05 2 L2 12 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES ~ 3 4 F TR1 24 Vac HOT 24 Vac COM N 2 + TR N1 1 5 MINIMUM POSITION ADJUSTMENT P1 C7150B MIXED AIR OR C7046A DISCHARGE AIR SENSOR P T1 + 1 0/2-10 VDC INDOOR AIR SENSOR MS7XXX HONEYWELL ACTUATOR – T AQ1 – 2 5 AQ + SO+ 3 4 EF EF1 SO SR+ SR C7400 OUTDOOR AIR ENTHALPY SENSOR + 4 W7212 3 620 OHM RESISTOR S C L1 (HOT) L2 COOL 1 Y1 Y1 EXHAUST FAN Y2 5 W2 W1 W2 HEAT 2 W1 HEAT 1 FAN DELAY RELAY G RH UNOCCUPIED ST6008 TIMER 6 OCCUPIED FDR G RC FAN FDR R X HVAC EQUIPMENT TERMINAL STRIP THERMOSTAT 2 L2 1 L1 (HOT) 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 ENSURE THAT TRANSFORMER IS SIZED TO HANDLE THE EXTRA LOAD OF THE ECONOMIZER AND ACTUATOR. 3 FACTORY INSTALLED 620 OHM, 1 WATT, 5% RESISTOR SHOULD NOT BE REMOVED. DIFFERENTIAL ENTHALPY NOT RECOMMENDED FOR USE WITH SINGLE-STAGE COOLING SYSTEMS OR SINGLE-STAGE COOLING THERMOSTATS. 4 EF AND EF1 ARE DRY CONTACTS IN THE LOGIC MODULE. 5 SEE WIRING DIAGRAMS FIGS 9 AND 10 FOR T7350 AND TB7220/TB8220. 6 TIME CLOCK IS AN OPTION TO USING OCCUPIED CONTACTS ON THE THERMOSTAT. M13659 Fig. 11. W7212A used in single-stage cooling system with single enthalpy changeover and Honeywell actuator and time clock for occupancy. 13 63-2596—05 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES TR TR1 24 Vac HOT 24 Vac COM N1 ~ N 1 2 + 3 4 F 5 MINIMUM POSITION ADJUSTMENT P1 C7150B MIXED AIR OR C7046A DISCHARGE AIR SENSOR P T1 + 1S 0/2-10 VDC INDOOR AIR SENSOR MS7XXX HONEYWELL ACTUATOR – T 3 AQ1 – 1K 1 2K 2 5 AQ + SO+ 3 4 EF EF1 1S1 SO SR+ SR C7400 OUTDOOR AIR ENTHALPY SENSOR + W7212 5 7 620 OHM RESISTOR S C Y1 COOL 1 Y2 COOL 2 W2 W2 HEAT 2 W1 W1 HEAT 1 Y1 W Y2 R T6031 AMBIENT LOCKOUT CONTROL 50 F SETPOINT 8 RH RC R HVAC EQUIPMENT TERMINAL STRIP T7300 OR T874 THERMOSTAT 2 ENSURE THAT TRANSFORMER IS SIZED TO HANDLE THE EXTRA LOAD OF THE ECONOMIZER AND ACTUATOR. 3 1S IS AN ELECTRONIC SWITCH THAT CLOSES WHEN POWERED BY A 24 VAC INPUT. 4 FOR T7300 ONLY 5 FACTORY INSTALLED 620 OHM, 1 WATT, 5% RESISTOR SHOULD BE REMOVED ONLY WHEN A C7400 ENTHALPY SENSOR IS ADDED TO SR AND SR+ FOR DIFFERENTIAL ENTHALPY. FAN FDR X POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. UNOCCUPIED 6 ST6008 TIMER 9 OCCUPIED FDR G 1 EXHAUST FAN FAN DELAY RELAY G 4 L1 (HOT) L2 6 2 L2 1 L1 (HOT) USE THE FOLLOWING CONTACTS INSTEAD OF TIMER FOR T7300, USE A1 AND A2 TERMINALS. FOR T7350 USE AUX TERMINAL. FOR TB7220 OR TB8220 USE A TERMINAL THE TERMINALS ARE CONNECTED WHEN THERMOSTAT IS IN THE OCCUPIED MODE. 7 EF AND EF1 ARE DRY CONTACTS IN THE LOGIC MODULE. 8 SEE WIRING DIAGRAMS FIGS 9 AND 10 FOR T7350 AND TB7220/TB8220. 9 TIME CLOCK IS AN OPTION TO USING OCCUPIED CONTACTS ON THE THERMOSTAT. M13660 Fig. 12. W7212A used in two-stage cooling system with Honeywell Series 72 Actuator and time clock for occupancy. 63-2596—05 14 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES 1 L2 2 L1 (HOT) ~ 1 2 + N1 3 4 F 5 C7150B MIXED AIR OR C7046A DISCHARGE AIR SENSOR 0/2-10 VDC INDOOR AIR SENSOR 3 T1 + – – 2 5 AQ + SO+ 3 4 EF EF1 SO SR+ SR W7212 4 1 24 Vac COM AQ1 MS7XXX HONEYWELL ACTUATOR L1 (HOT) 24 Vac HOT T 5 UNOCCUPIED 3 ST6008 7 TIMER TR1 1 4 F P 1 2 + MINIMUM POSITION ADJUSTMENT P1 MS7XXX HONEYWELL ACTUATOR ~ TR N C7400 OUTDOOR AIR ENTHALPY SENSOR + 620 OHM RESISTOR 5 S OCCUPIED L2 C 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 ENSURE THAT TRANSFORMER IS SIZED TO HANDLE THE LOAD OF ALL ACTUATORS. 3 USE THE FOLLOWING CONTACTS INSTEAD OF TIMER FOR T7300, USE A1 AND A2 TERMINALS. FOR T7350 USE AUX TERMINAL. FOR TB7220 OR TB8220 USE A TERMINAL THE TERMINALS ARE CONNECTED WHEN THERMOSTAT IS IN THE OCCUPIED MODE. 4 FACTORY INSTALLED 620 OHM, 1 WATT, 5% RESISTOR SHOULD BE REMOVED ONLY WHEN A C7400 ENTHALPY SENSOR IS ADDED TO SR AND SR+ FOR DIFFERENTIAL ENTHALPY. Y1 Y1 COOL 1 Y2 Y2 COOL 2 W2 W2 HEAT 2 W1 W1 HEAT 1 RH FDR G FAN FDR X R THERMOSTAT HVAC EQUIPMENT TERMINAL STRIP 5 EF AND EF1 ARE DRY CONTACTS IN THE LOGIC MODULE. 6 SEE WIRING DIAGRAMS FIGS 9 AND 10 FOR T7350 AND TB7220/TB8220. 7 TIME CLOCK IS AN OPTION TO USING OCCUPIED CONTACTS ON THE THERMOSTAT. 6 EXHAUST FAN FAN DELAY RELAY G RC L1 (HOT) L2 L2 1 L1 (HOT) M13661 Fig. 13. W7212 controlling parallel-wired Honeywell Series 72 Actuators and time clock for occupancy. 15 63-2596—05 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES ~ 1 2 + 5 3 O 4 F TR TR1 24 Vac HOT 24 Vac COM N MINIMUM POSITION ADJUSTMENT P1 5 P T1 C7150B DISCHARGE AIR SENSOR MS7XXX HONEYWELL ACTUATOR 0/2-10 VDC INDOOR AIR SENSOR + – T 1 2 AQ1 – 4 AQ + SO+ 3 5 EF EF1 SO SR+ SR W7214 3 C7400 OUTDOOR AIR ENTHALPY SENSOR 2 620 OHM RESISTOR + S A3 4 C A2 Y1 Y1 COOL 1 Y2 Y2 COOL 2 W2 W2 HEAT 2 W1 W1 HEAT 1 G G FAN RH L1 (HOT) L2 EXHAUST FAN L2 R RC 1 L1 (HOT) X O T7300 THERMOSTAT 5 O HVAC EQUIPMENT TERMINAL STRIP 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 EF AND EF1 ARE DRY CONTACTS IN THE LOGIC MODULE. 3 FACTORY INSTALLED 620 OHM, 1 WATT, 5% RESISTOR SHOULD BE REMOVED ONLY WHEN A C7400 ENTHALPY SENSOR IS ADDED TO SR AND SR+ FOR DIFFERENTIAL ENTHALPY. 4 T7300 TERMINALS A2 AND A3 ARE CONNECTED WHEN THERMOSTAT IS IN THE UNOCCUPIED MODE. SEE FIGS. 9 AND 10 FOR T7350 AND TB7220/TB8220 WIRING. 5 W7213: B TERMINAL W7214: O TERMINAL M19618C Fig. 14. W7213, W7214 controlling heat pump system. 63-2596—05 16 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES CHECKOUT AND TROUBLESHOOTING W7212 Checkout requires a 9V battery, 620 ohm, 1.2K ohm, 5.6K ohm, and 6.8K ohm resistors. Use Table 3 and Fig. 15 for checkout. N1 N 2V EXH Set 10V EXH P1 P Min Pos T1 1 DC VOLTMETER CAUTION Equipment Damage Hazard. Excessive force can damage potentiometer controls. Use a small screwdriver when adjusting enthalpy changeover and minimum damper position controls. Open T DCV + 2V AQ1 DCV AQ SO+ C7400 S 2V SO + SR+ SR Max 10V DCV Set 10V Free Cool B C A D 2 620 OHM RESISTOR 1 INSERT DC VOLTMETER BETWEEN AQ AND AQ1 FOR CHECKOUT AND TROUBLESHOOTING. 2 JUMPER USED FOR SINGLE ENTHALPY CONTROL. M20612 Fig. 15. Meter location for checkout and troubleshooting (W7212 shown). Table 3. Checkout for W7212, W7213, W7214 Economizers Connected to Honeywell Actuator. Step 1. Checkout Procedure Proper Response CHECKOUT PREPARATION Disconnect power at TR and TR1. All LED are off; Exhaust Fan contacts are open. Disconnect devices at P and P1. Jumper P to P1. Place 5.6K ohm resistor across T and T1. Jumper TR to 1. W7212 only: Jumper TR to N. If connected, remove C7400 Enthalpy Sensor from terminals SO and +. Connect 1.2K ohm 4074EJM Checkout Resistor across terminals SO and +. Put 620 ohm resistor across SR and +. Set minimum position, DCV setpoint, and Exhaust potentiometers fully CCW. Turn DCV maximum position potentiometer fully CW. Set enthalpy potentiometer to D. W7214 only: Jumper TR to O. Apply power (24 Vac) to terminals TR and TR1. 2. 3. DIFFERENTIAL ENTHALPY Execute step one, Checkout Preparation. — Place 620 ohm resistor across SO and +. — Place 1.2K ohm resistor across SR and +. Free cool LED turns on. Remove 620 ohm resistor from SO and +. Free cool LED turns off. SINGLE ENTHALPY Execute step one, Checkout Preparation. — Set enthalpy potentiometer to A (fully CCW). Free cool LED turns on. Set enthalpy potentiometer to D (fully CW). Free cool LED turns off. 17 63-2596—05 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES Table 3. Checkout for W7212, W7213, W7214 Economizers Connected to Honeywell Actuator. (Continued) Step 4. 5. Checkout Procedure Proper Response DCV AND EXHAUST Execute step one, Checkout Preparation. — Ensure terminals AQ and AQ1 are open. LED for both DCV and Exhaust should be off. Actuator drives fully closed. Connect 9V battery positive to AQ and negative to AQ1. LED for both DCV and Exhaust turn on. Actuator drives to between 81 and 85 degrees open. Turn Exhaust potentiometer CW until Exhaust LED turns off. Exhaust LED turns off with potentiometer approximately 90 percent CW. Actuator remains in position. Turn DCV setpoint potentiometer CW. DCV LED turns off with potentiometer at approximately 9V. Actuator drives fully closed. Turn DCV setpoint potentiometer CCW until Exhaust LED turns on. Exhaust contacts close 30-90 seconds after Exhaust LED turns on. Turn DCV setpoint potentiometer CW. Exhaust LED turns off with potentiometer indication at approximately 9V. Turn Exhaust potentiometer CCW until Exhaust LED turns on. Exhaust contacts close 30-90 seconds after Exhaust LED turns on. MINIMUM AND MAXIMUM POSITION Execute step one, Checkout Preparation. — Connect 9V battery positive to AQ and negative to AQ1. DCV LED turns on. Actuator drives to between 81 and 85 degrees open. Turn DCV maximum position potentiometer to midpoint. Actuator drives to between 18 and 72 degrees open. Turn DCV maximum position potentiometer to fully CCW. Actuator drives fully closed. Turn minimum position potentiometer to midpoint. Actuator drives to between 18 and 72 degrees open. Turn minimum position potentiometer fully CW. Actuator drives fully open. W7212: Remove jumper from TR and N. Actuator drives fully closed. W7213, W7214: Jumper TR to N. 6. 7. MIXED AIR INPUT Execute step one, Checkout Preparation. — Set enthalpy potentiometer to A. Free cool LED turns on. Actuator drives to between 18 and 72 degrees open. Remove 5.6K ohm resistor and jumper from T and T1. Actuator drives fully open. Remove jumper from T and T1 and leave open. Actuator drives fully closed. HEAT PUMP INPUT - W7213, W7214 ONLY Execute step one, Checkout Preparation. — Set enthalpy potentiometer to A. Free cool LED turns on. Actuator drives to between 18 and 72 degrees open. W7213: Jumper TR to B. W7214: Remove jumper from TR and O. Free cool LED turns off. Actuator drives fully closed. 63-2596—05 18 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES 19 63-2596—05 W7212, W7213, W7214 ECONOMIZER LOGIC MODULES Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Registered Trademark © 2009 Honeywell International Inc. 63-2596—05 M.S. Rev. 01-09 ll C7660 Selectable Temperature Sensor FOR ECONOMIZERS FEATURES Senses temperature of outdoor air and provides a signal to economizer control with OK or not OK to economize. Selectable dip switch provides 8 change over temperature options. When temperature of outdoor air is below change over temperature, the outdoor air damper is opened to reduce the cooling load in the building. Provides 4 OR 20 mA output signal to economizer control; At 4 mA not OK to economize, 20 mA OK to economize. Highly accurate microprocessor control. Sensor is enclosed in a rugged, corrosion-resistant plastic case. Replaces C7650 temperature sensors and the control function of temperature change over in the economizer control. GENERAL C7660 Selectable Temperature Sensor is used with the W7459, W7215, W7212, W7213 and W7214 Economizer Controls. The economizer controls are mounted on an M7415/ M7215 Actuator. They permit the use of outdoor air as the first stage of cooling in heating, ventilating and air conditioning (HVAC) systems. The C7660 Selectable Temperature Sensor is only to be used with single temperature change over with the sensor located in the outdoor air. Contents General ............................................................................1 Features............................................................................1 Specifications ...................................................................1 Ordering Information ........................................................2 Installation ........................................................................2 Operation .........................................................................3 63-2670EF-01 SPECIFICATIONS 5/16 (8) Model: C7660 Selectable Temperature Sensor Case: Duct mount Temperature Sensing Element: Thermistor Output Signal: 4mA not OK to economize, 20 mA OK to economize Operating Ambient Temperature Range: -40° to 149° F (-40° to 65° C). Shipping Temperature Range: -40° to 149° F (-40° to 65° C). Supply Voltage: Power to sensor is supplied through economizer or if not used with an economizer, logic power input is 21.6 vdc ± 1.5 vdc. Electrical Connections: Two 1/4 in. (6.4 mm) quick connect terminals. Approval: Underwriters Laboratories Inc. Flammability Rating UL94-5V M27634 1 (25) Fig. 1. C7660 Selectable Temperature Sensor Dimensions in in. (mm). INSTALLATION When installing this Product... 1. Dimensions: See Fig. 1 Hysteresis: Hysteresis +/- 1F; Economizer Cut-in 1F below setpoint, Cut-out 1F above setpoint 3. 4. 4. Accuracy: ± 1° F 5. 6. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. Installer must be a trained experienced service technician. After installation is complete, check out product operation as provided in these instruction. Verify dip switch settings match desired changeover outside air temperature. Verify polarity of wiring connections from sensor to controller is correct. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada–Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 63-2670EF–01 2 C7660 SELECTABLE TEMPERATURE SENSOR W7459 ECONOMIZER PACKAGE MOUNTED ON ACTUATOR 1 SEE W7459 SPECIFICATIONS FOR ADDITIONAL WIRING INFORMATION. 2 POLARITY OF SENSOR IS REQUIRED TO CONNECT + ON SENSOR TO + ON ECONOMIZER AND - ON SENSOR TO SO ON ECONOMIZER 3 ONLY ONE C7660 SENSOR CAN BE USED WITH AN ECONOMIZER FOR SINGLE DRY-BULB CHANGEOVER. DO NOT USE A SECOND C7660 SENSOR ON THE SR AND SR+ TERMINALS. Fig. 2. Wiring Connections for C7660 Temperature Sensor. CAUTION 1. Before beginning installation, disconnect power supply to prevent electrical shock or equipment damage. 2. When selecting the location, make sure the sensor is not exposed to rain, snow or direct sunlight. Location The C7660 Temperature Sensor can be mounted in any position; however, the sensor must be installed where it is exposed to freely circulating air but protected from rain and direct sunlight. Wiring Disconnect power supply before beginning installation to prevent electrical shock or equipment damage. All wiring must comply with applicable codes and ordinances. Follow the wiring information furnished by the equipment manufacturer or see Fig. 2 for typical wiring hookups. OPERATION Temperature Change Over Control Setting The temperature change over setpoint is made by changing the setting on a 3-position dip switch through the cover of the sensor. See Fig. 3 for temperature change over settings. Operation The C7660 Selectable Temperature Sensor is used with an economizer control and damper actuator to proportion an outdoor air damper in a ventilation system. When outdoor air temperature is below the change over setpoint, the sensor will provide a 20 mA signal to the economizer with translate to OK to economize positioning the damper open on a call for cooling. When the outdoor air is above the change over setpoint, the sensor provides a 4 mA signal to the economizer which translates to not OK to economize and the outdoor damper drives to minimum position. The C7660 temperature sensors replace the control function of the temperature changeover in the economizer control. The A, B, C, D potentiometer on the economizer does not control the changeover point when a C7660 sensor is used in place of an enthalpy sensor. This potentiometer is only adjusted when using a C7400 enthalpy sensor for single enthalpy changeover. For single dry-bulb and differential enthalpy set the potentiometer to —D“. 3 63-2670EF–01 The changeover temperature switch settings for the C7660 are shown in Fig. 3. Default and factory setpoint is 63° F. Changeover on an economizer can operate in two basic modes: 1) exclusive operation where either the economizer or the mechanical cooling function, but not both OR 2) integrated operation where the economizer and mechanical cooling operate at the same time. Integrated operation requires a two stage cooling thermostat. The integrated control will provide the most energy savings. For exclusive operation, the changeover set point needs to allow mechanical cooling when the economizer can no longer meet the cooling load requirement. The 63 degree F setting is the most typical changeover set point for this type of control but is dependent on the building and climate. For integrated operation, the changeover should be just at or just below the typical cooling setpoint expected in the zone served. For example, if the cooling setpoint is 74 degrees F or 75 degrees F, the changeover setpoint should be set at 73 degrees F. DIP SWITCH CHANGEOVER TEMPERATURE POSITION ON OFF 123 ON OFF 123 48ºF 53ºF ON OFF 123 55ºF ON OFF 123 58ºF ON OFF 123 ON OFF 123 ON OFF 123 ON OFF 123 63ºF 68ºF 73ºF 78ºF M27636 Fig. 3. C7660 Temperature Sensor Dip Switch Settings. Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Golden Valley, MN 55422 customer.honeywell.com Toronto, Ontario M1V 4Z9 ® U.S. Registered Trademark © 2008 Honeywell International Inc. 63-2670EF–01 M.S. 09-08 ll ll I&M011-10130_CXLdp:Layout 1 2/26/09 9:23 AM Page 1 MODEL CXLdp DIFFERENTIAL PRESSURE TRANSDUCER INSTALLATION & MAINTENANCE SHEET WARNING! READ BEFORE INSTALLATION 1. GENERAL: A failure resulting in injury or damage may be caused by excessive overpressure, excessive vibration or pressure pulsation, excessive instrument temperature, corrosion of the pressure containing parts, or other misuse. Consult Ashcroft Inc., Stratford, Connecticut, USA before installing if there are any questions or concerns. 2. OVERPRESSURE: Pressure spikes in excess of the rated overpressure capability of the transducer may cause irreversible electrical and/or mechanical damage to the pressure measuring and containing elements. 3. STATIC ELECTRICAL CHARGES: Any electrical device may be susceptible to damage when exposed to static electrical charges. To avoid damage to the transducer the operator/installer should follow proper ESD (electrostatic discharge) protection procedures before handling the pressure transducer. 4. USE IN LIFE SUPPORT DEVICES: Ashcroft Inc. products are not authorized for use as critical components in life support devices or systems without the express written approval of the General Manager, Stratford Operations of Ashcroft Inc. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. SPECIFICATIONS INSTALLATION Accuracy: (2) options,specified at time of order. • ±0.8% span - (±0.128ma for 4-20ma output units) - (±0.08V for 0-10Vdc output units) • ±0.4% Span - (±0.064ma for 4-20ma units) - (±0.04V for 0-10Vdc output units) Mounting: Output Signal: Specified at time of order. • 4-20ma (For symmetric bidirectional ranges 0IW= 12ma) • 0-10Vdc; 0-5Vdc User selectable option (For symmetric bidirectional ranges 0IW= 5 or 2.5Vdc respectively). Supply Voltage: • 4-20ma: 12-36 Vdc (no regulation required) (see Figure 1) • 0-10Vdc (0-5Vdc User selectable option): 1436 Vdc or 24 Vac (+/- 20%) Figure 1 Load Limitations 4-20mA Output The transmitter can be mounted on a 35 mm DIN rail or with #8 or #10 screws using the 4 mounting holes provided. Torque limits on the mounting holes provided is 6 inch-pounds. (see Figure 3) Figure 3 Use #10 screw or Use #8 screw Green LED Zero Pot Electrical Wiring: 1. Remove the terminal block on the front of the transmitter. 2. Follow the terminal block label markings on the CXLdp to identify the terminals; • 4-20ma Ouput: The left, negative (-), and right, positive (+) terminals are used, ignore the center terminal which is not used. Connect the power supply positive lead to the CXLdp positive terminal, connect the negative power supply lead to the negative terminal of the BCS 4-20ma input. Last, connect the (-) negative terminal on the CXLdp to the (+) positive BCS input. Loop Resistance (Ω) TING Vmin = 12V+ [.022A*(RL)] *includes a 10% safety factor RL = RS + RW RL = Loop Resistance (ohms) RS = Sense Resistance (ohms) RW = Wire Resistance (ohms) ZERO SPAN – + Loop Supply Voltage (Vdc) * F.S. pressure is equivalnt to the span of the transmitter (16mA). Zero adjust potentiometer Span adjust potentiometer + Reverse Wiring Protected + BCS – POWER – SUPPLY Electrical Connection: unpluggable terminal block accepts 12-26 AWG Operating Temperature: 0-160°F Enclosure: NEMA 1 Fire-retardant ABS Meets UL 94-5VA DESCRIPTION Weight: Approx. 2.5 oz. The Ashcroft® Model CXLdp is a low differential pressure transmitter to be used on clean, dry, non-corrosive gases. It is available in two accuracy classes and its performance is traceable to the U. S. National Institute of Standards and Technology (NIST). The 8 or 4 located in the third position of the product code distinguishes a 0.8% from a 0.4% accuracy transmitter. Both unidirectional (e.g. 0 to +1.0 IW) or bi-directional (e.g. ±2.0 IW) models are available. A green LED located on the front of the transmitter indicates power and operational status. The LED light intensity increases as pressure increases. Pressure Connection Options: 1⁄4˝ Brass Barbs or 1⁄8 NPT Female Brass Optional: 1⁄2˝ conduit or plenum mounting bracket and cover available as separately ordered kit – part number 101A213-01. (see Figure 2) • 0-10Vdc; 0-5Vdc Output: Follow label markings for terminal assignments; COM is for Common (supply and output negative), VIN is for supply positive and VOUT is for output signal. The CXLdp Voltage Output unit is supplied as standard with 0-10 V output, to convert to 0-5 V output see following instructions. Figure 2 Ashcroft Inc. 250 East Main Street 06614, Tel: 203-378-8281 • Fax: 203-378-0499, All specifications are subject to change without notice. © Copyright 2009. All sales subject to standard terms and conditions. www.ashcroft.com All rights reserved. I&M011-10130 AMR 1M 02/09 ZERO Zero adjust potentiometer SPAN Span adjust potentiometer COM VOUT VIN I&M011-10130_CXLdp:Layout 1 2/26/09 9:23 AM Page 2 MODEL CXLdp DIFFERENTIAL PRESSURE TRANSDUCER INSTALLATION & MAINTENANCE SHEET - 0-10 Vdc Output: Product is supplied as standard with 0-10 V output, see instruction below to access the Voltage Output jumper. - 0-5 Vdc Output: See below for proper jumper selection. To convert the unit from a 0-10 V output to a 0-5 V output unit note the following. Access the jumper by simultaneously pushing both housing tabs away from the housing, see drawings under “General Dimensions” for details. Change Figure 4 Jumper jumper (orange) (orange) into position as 0-10 Vdc shown below, carefully reattach housing cover. When finished mark check box on front label in0-5 Vdc dicating that the unit now provides a 0 – 5Vdc output. Label Part No. 238A713-01 3. Firmly reinstall the terminal block plug to its mating connector. Set Up: The transmitters are calibrated at the factory in the vertical position. Mounting in the horizontal position can cause a zero shift of as much as ±1% F.S. in ranges below 1 IW dp. Any minor zero offset can be minimized using the zero adjust potentiometer located on the front, left side of the instrument. To find true zero differential pressure, pneumatically connect the high and low pressure connections together using the tubing provided with the transmitter. The Figure 5 barbed connection accept 1⁄4˝ O.D. 1⁄8˝ I.D. tubing. (see Figure 5) When 1⁄8 NPT female brass fittings are used, do not exceed 60 inchpound torque force on female NPT fitting. When connecting to the NPT fittings, do not apply torque to the CXLdp fitting. Use a 9⁄16˝ wrench to hold the CXLdp. (see Figure 6) Figure 6 Zero potentiometer adjustment requires using a 3⁄32˝ or 2.5 mm slotted or phillips screwdriver. The tubing should remain in place until the transmitter is to be connected to the BCS tubing system. (see Figure 7) GENERAL DIMENSIONS FOR MODEL CXLdp (in inches) MB2 1⁄4˝ BARB FITTINGS "B2" 1/4 BARB FITTINGS 1.45 Zero and Span Potentiometers .37 1.32 ÿ .20 Figure 7 ZERO POWER SPAN Zero adjust potentiometer Span adjust potentiometer HI LO ZERO SPAN 2.90 3.33 ÿ .16 HOUSING TABS (2) Routine Maintenance: 1.89 The CXLdp is a very stable and reliable transmitter incorporating a proven, micro-machined silicon capacitive sensor and a new, state-of-the-art application specific integrated circuit (ASIC). All calibration and temperature compensation functions are done with a microprocessor and digital routines. To troubleshoot or verify performance, it is recommended to pneumatically connect the pressure ports to each other and establish a zero offset reading in the as-installed position. Adjusting zero will not affect span calibration. F01 1⁄8 NPT FEMALE FITTINGS "01" 1/8 FEMALE NPT FITTINGS 1.45 .37 1.32 POWER .56 Adjusting span should only be attempted when a high accuracy pressure standard and high quality electrical meter are able to be used. HI LO ZERO SPAN 2.90 3.33 1.89 DIN Rail Transmitter Removal: In order to remove the transmitter when it is installed on a DIN rail, it is necessary to first unplug the wiring terminal block from the transmitter. Insert a small slotted screwdriver into the black plastic clip extending slightly below the transmitter case. (see Figure 8) ASSEMBLED WITH 101A213-01 CONDUIT KIT ASSEMBLED WITH 101A213-01 CONDUIT KIT Figure 8 4.85 Next, raise the screwdriver handle up thereby forcing the spring clip down. If questions or concerns need to be addressed, our Low Pressure Product Manager or Engineering Personnel can be contacted at (203) 378-8281 or visit our website at www.ashcroft.com. 2.06 R .88 .78 Ashcroft Inc. 250 East Main Street 06614, Tel: 203-378-8281 • Fax: 203-378-0499, All specifications are subject to change without notice. © Copyright 2009. All sales subject to standard terms and conditions. www.ashcroft.com All rights reserved. I&M011-10130 AMR 1M 02/09
Similar documents
In stal la tion In struc tions Pack age Unit Mod u lat ing Economizer
screwdriver until the mixed air temperature reaches the calculated value. Ensure both sets of damper blades operate properly. 9. Once minimum position adjustments are completed, turn off power to t...
More information