Power Pedestals
Marina Power and Lighting Equipment
6.5
Contents
Marina Power and Lighting Equipment
Description
High-Quality, Weatherproof Electrical Equipment
Page
Power Pedestals
Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint . . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels. . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
6
6
336
338
342
346
349
353
357
363
364
365
366
367
370
373
374
Learn
Online
6
6
6
6
6
6
6
6
6
6
6
6
Power Pedestals
Product Overview
Known as a leader in
electrical control, power
distribution, and industrial
automation products and
services, Eaton is a quality
driven company that
constantly looks for ways to
provide enhanced product
and service solutions for their
customers. Eaton will be able
to provide Marina developers
a complete electrical solution.
For more information on
the other products available
from Eaton, visit us online
at www.eaton.com or
www.marinapower.com.
6
What Eaton has to Offer
●
Eaton has more marina
power outlets in service
than all other suppliers
combined
●
We offer complementary
comprehensive in-house
electrical designs for
your complete marina
development using all high
quality Eaton products
●
We can provide your
marina development with
complete remote wireless
digital electronic meter
reading
●
Not only can Eaton provide
your marina with the
highest quality power
pedestals and marine
distribution equipment, we
can also supply your entire
electrical needs for your
surrounding development
and beyond from safety
switches to loadcenters
and much more
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
335
6.5
6
6
Power Pedestals
Marina Power and Lighting Equipment
Product Selection Guide
Power Pedestal Quick Guide
6
Lighthouse
Newport
Lighthouse–SS Hatteras Light Harbor Mate
Admiral–SS
Firehouse
Mariner
Lookout
Power Point
6
Main housing
Engineered resin
Stainless steel
Engineered resin
Engineered resin
Stainless steel
Stainless steel
Engineered resin
Stainless steel
Stainless steel
Top
Engineered resin
Engineered resin
Engineered resin
Engineered resin
Stainless steel
Engineered resin
Engineered resin
Stainless steel
Stainless steel
6
Optional stand
—
—
—
Stainless steel
—
—
PVC
—
—
External hardware
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Standard lightwattage(s)
13W
13W
13W
7W
13W
13W
5W, 7W & 13W
—
13W
6
LED lighting option
Yes
Yes
Yes
No
Yes
Yes
No
No
Yes
Photocell
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
6
Lockable doors
Yes
Yes
Yes
Yes
Yes
—
—
—
Yes
Hose hangers
Yes
Yes
No
No
Yes
No
No
No
No
6
6
6
6
6
6
6
6
6
Electric meters
Yes—up to 4
Yes—up to 4
Yes—up to 2
Yes—up to 2
Yes—up to 4
No
No
No
Yes—up to 6
Remote meter reading
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Water
Two 3/4”
Two 3/4”
Two 1/2”
Two 3/4”
Two 3/4”
None
None
None
One 3/4” or more
Water meters
Yes
Yes
No
Yes
Yes
No
No
No
Yes
Telephone
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Cable TV
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Internet
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Fire extinguisher
No
No
No
No
No
Yes—up to 20 lbs
No
No
No
Life ring
No
No
No
No
No
Yes—24”
No
No
No
Alarm and strobe light
No
No
No
No
No
Yes
No
No
No
20A 110V GFI
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
30A 125V twist—lock
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
50A 125/250V twist—lock
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
6
100A 120/240V pin and sleeve
Yes
Yes
No
No
Yes
No
No
No
Yes
100A 120/208V pin and sleeve
Yes
Yes
No
No
Yes
No
No
No
Yes
6
100A 277/480V pin and sleeve
Yes
Yes
No
No
Yes
No
No
No
Yes
100A 480V pin and sleeve
Yes
Yes
No
No
Yes
No
No
No
Yes
200A 480V pin and sleeve
No
No
No
No
Yes
No
No
No
Yes
6
Hardwire compatible
No
No
No
No
No
No
No
No
Yes
TVSS compatible
Yes
Yes
No
No
Yes
No
No
No
Yes
6
Card swipe compatible
Yes
Yes
No
Yes
Yes
No
No
No
Yes
Security camera compatible
No
No
No
No
No
No
No
Yes
No
Bus bar rating
Up to 500A
Up to 500A
Up to 140A
Up to 140A
Up to 500A
—
—
—
Up to 800A
Maximum wire size—single feed
350 kcmil
350 kcmil
#2/0
#2/0
350 kcmil
—
—
—
(3) 500 kcmil
Maximum wire size—loop feed
#4/0
#4/0
#1
#1
350 kcmil
—
—
—
(3) 500 kcmil
Height
44”
40”
30”
36”
48”
43.5”
24” to 72”
72” to 96”
50”
Width
13.75”
9.875”
7.5”
10.5”
14”
9.875”
7”
9”
50”
Depth
13.75”
9.875”
7.5”
14.5”
14”
9.875”
7”
9”
36”
Housing
Limited lifetime
Limited lifetime
Limited lifetime
Limited lifetime
Limited lifetime Limited lifetime
Limited lifetime
Limited lifetime Limited lifetime
Receptacles and breakers
2 years
2 years
2 years
2 years
2 years
—
—
—
2 years
Lighting assembly
1 year
1 year
1 year
1 year
1 year
1 year
1 year
—
1 year
6
6
6
6
6
6
6
Warranty
6
6
6
336
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
Receptacles
6.5
Receptacle Configuration Availability
Side One
Lighthouse
Side Two
None
None
None
30A
None
30A
30A
30A
None
30A
30A
30A
50A
None
30A
None
30A
50A
50A
None
50A
50A
50A
None
50A
100A 120/240V
Lighthouse–SS
Admiral–SS
Hatteras Light
Newport
Harbor Mate
None
Receptacle Available with GFI Receptacles
None
None
Yes
Yes
Yes
Yes
Yes
None
None
Yes
Yes
Yes
Yes
Yes
30A
None
Yes
Yes
Yes
No
Yes
30A
30A
Yes
Yes
Yes
Yes
No
None
Yes
Yes
Yes
No
No
50A
None
Yes
Yes
Yes
No
Yes
30A
50A
Yes
Yes
Yes
Yes No
None
None
Yes
Yes
Yes
No
No
None
None
Yes
Yes
Yes
Yes
Yes
50A
None
Yes
Yes
Yes
No
Yes
50A
50A
50A
Yes
Yes
Yes
No
No
None
None
None
Yes
Yes
Yes
No
No
100A 120/240V
None
50A-50A
None
Yes
Yes
Yes
No
No
100A 120/240V
None
100A 120/240V
None
Yes
Yes
Yes
No
No
100A 120/240V
50A-50A
100A 120/240V
50A-50A
Yes
Yes
Yes
No
No
100A 120/208V
None
None
None
No
No
Yes
No
No
100A 120/208V
None
100A 120/240V
None
Yes
Yes
Yes
No
No
100A 120/240V
100A 120/240V
100A 120/240V
100A 120/240V
Yes
Yes
Yes
No
No
100A 120/208V
100A 120/208V
100A 120/208V
100A 120/208V
No
No
Yes
No
No
100A 120/240V
100A 120/240V
100A 120/208V
100A 120/208V
No
No
Yes
No
No
No
No
Yes
No
No
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Note
Configuration available with no additional GFI receptacles.
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
337
6.5
6
Power Pedestals
Marina Power and Lighting Equipment
Contents
Lighthouse
Description
6
Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse
Available Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters. . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint. . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
6
6
6
6
6
6
6
6
6
6
335
339
340
341
341
342
346
349
353
357
363
364
365
366
367
370
373
374
6
6
Lighthouse
6
Product Description
6
6
6
6
6
6
6
6
6
One of our most popular
units, the all-purpose
Lighthouse® pedestal has a
wide range of features. With
units in service around the
world, this stylish power
pedestal is recognized for its
practicality and exceptional
durability.
Engineered to withstand
the most severe weather
conditions, Lighthouse
power pedestals can be
found in marinas from
Alaska to the tropics.
Features, Benefits
and Functions
●
●
●
●
Note: Custom paint color.
●
Note: Wireless remote reading
of electronic kilowatt meters.
●
Note: Clear lens.
6
●
6
Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Lockable weatherproof
doors that protect breakers
and receptacles while in
use (a requirement of NFPA
303 and NEC Article 555)
Hose and cable brackets
Heavy resin housing with
a two-part polyurethane
coating for a UV-resistant,
long-lasting finish
Copper bus bar with
ratings from 250 to 500A
New “hingeless” base
providing easy access for
both installation and
maintenance
Backlit faceplate for easy
receptacle plug-in at night
6
6
6
6
338
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
Lighthouse
6.5
Available Options
●
360° controlled 13 watt fluorescent light
with amber lens for bug reduction
●
●
Digital electronic metering for each side
Lockable weatherproof doors that
protect breakers and receptacles
6
Digital electronic metering
(one, two or three element
meters available)
Built-in meter socket
20A/125V GFI receptacle
(max. of two GFI
receptacles per pedestal)
6
6
6
Note: 20A GFI receptacles are
not to be used for shore power.
Receptacle configuration available
30A, 50A, 30A/30A, 30A/50A,
50A/50A, 100A, Empty
Note: Custom configurations also available
●
●
Hose and cable brackets
●
1/4-inch Resin housing with a two-part
polyurethane coating for a UV resistant,
long-lasting finish
20A/125V GFI receptacle
●
Phone and cable TV connections
High-speed Internet connections (RJ45) for
each side
●
●
●
●
●
●
6
High-speed Internet
connections
Wireless remote metering
for electric and water
Transient voltage surge
suppressor (TVSS) to
protect from voltage
surges, spikes or lightning
on the AC power line
(extends warranty on
internal parts to three
years)
Stainless steel door hinge
on receptacle main doors
Single or dual steel 1/4-turn
ball valves with 3/4-inches
Hose bibs and stainless
steel handles
Single or dual phone and/or
cable TV connections
Base cap
Base extension
LED lighting
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Copper Bus Bar with Ratings
from 250 to 500A
Cable and Internet
Connections
6
6
6
6
New Hingeless Base
6
Optional Meter Socket
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
339
6.5
Marina Power and Lighting Equipment
Catalog Number Selection
L D U 4 7 0 0 0 0 0 0 1 2 K M
6
6
Type
L = Lighthouse
S = LHSS
6
6
6
6
Metering Type
U = Unmetered
D = Digital electronic meters
(side one)
T = Digital electronic meters
(side two)
B = Digital electronic meters
(both sides)
R = Receptacles metered
individually
M = One meter socket
(100A)
N = Two meter socket
(100A each)
V = 200A meter socket
6
6
6
6
6
6
6
6
6
6
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
= None
= 20A GFI duplex
= 30A, 125V
= 50A, 125V
= 50A, 125/250V
= 100A, 208V
= 100A, 250V
= 100A, 277/480V
= 100A, 480V
R4S2
6
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
R3S2
6
R2S2
6
Sides and Receptacles
R1S2
6
R4S1
6
R2S1
Lighting and Lens Color
A = 7W light
Amber
B = Dual 7W light Amber
C = 9W light
Amber
D = 13W light
Amber
E = Dual 13W light Amber
F = No lighting
Amber
G = 7W light
Clear
H = Dual 7W light Clear
I = 9W light
Clear
J = 13W light
Clear
K = Dual 13W light Clear
L = No lighting
Clear
M = 7W light
Special
N = Dual 7W light Special
O = 9W light
Special
P = 13W light
Special
Q = Dual 13W light Special
R = No lighting
Special
S = 350 MA LED
Amber
T = 700 MA LED
Amber
U = 350 MA LED
Clear
V = 700 MA LED
Clear
W = 350 MA LED
Special
Y = 700 MA LED
Special
6
R1S1
6
R3S1
6
Power Pedestals
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
Water Option =0
=1
=2
= Single water meter
= Dual water meter
= Single meter, 2V
= 1 frost free
= 2 frost free
Extra Unmetered GFI
Receptacles 0 = None
1 =1
2 =2
Phone Cable TV and Internet Options
Phone
Cable TV
Internet
Jack
Jack
Option
A = 1
0
0
B = 1
0
1
C = 1
0
2
D = 1
1
0
E = 1
1
1
F = 1
1
2
G = 1
2
0
H = 1
2
1
I = 1
2
2
J = 2
0
0
K = 2
0
1
L = 2
0
2
M= 2
1
0
N = 2
1
1
O = 2
1
2
P = 2
2
0
Q = 2
2
1
R = 2
2
2
S = 0
2
2
T = 0
0
1
U = 0
0
2
V = 0
1
0
W= 0
1
1
X = 0
1
2
Y = 0
2
0
Z = 0
2
1
0 = 0
0
0
Bus
S = Single-phase 3/8-inch copper bus bar
F = Three-phase 3/8-inch copper bus bar
C = Single-phase 3/8-inch Canadian bus bar
T = Three-phase 3/8-inch Canadian bus bar
M = Single-phase 300 kcmil mechanical lug bus
Z = Three-phase 300 kcmil mechanical lug bus
L = Single-phase 350 kcmil mechanical lug bus
P = Three-phase 350 kcmil mechanical lug bus
N = Single-phase 1/4-inch copper bus bar
Q = Single-phase 1/4-inch split mechanical bus bar
Receptacle: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
Notes
Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
Quantity of 20A GFI duplex receptacles.
6
6
6
6
6
6
340
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Accessories
See Page 359.
6
Dimensions
6
Approximate Dimensions in Inches (mm)
6
Lighthouse
6
6
6
6
6
6
6
Top
6
44.00
(1117.6)
6
6
6
6
6
6
6
Front View
Side View
6
6
6
6
6
6
6
6
6
13.75
(249.3)
6
Broken View
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
341
6.5
6
Power Pedestals
Marina Power and Lighting Equipment
Contents
Lighthouse–SS
Description
6
Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS
Available Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters. . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint. . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
6
6
6
6
6
6
6
6
6
6
335
338
343
344
345
345
346
349
353
357
363
364
365
366
367
370
373
374
6
6
Lighthouse–SS
6
Product Description
Features, Benefits
and Functions
6
The Lighthouse–SS offers
the same standard features
and available options as the
standard Lighthouse. But,
like all of the stainless steel
products manufactured here,
the Lighthouse–SS is made
with high-quality 316L
stainless steel for superior
quality and performance.
6
Note: 20/125A GFI receptacle.
6
Note: Wireless remote reading
of electronic kilowatt meters.
●
6
Note: Clear lens.
●
6
Note: Meter socket for each
side powered (to accept glass
style meter).
6
6
6
6
6
6
6
6
Note: Receptacle configurations
available:
30A
30A/30A
30A/50A
50A/50A
100A (single-phase) 120/240V
100A (three-phase) 120/208V
200A (three-phase) 480V
●
●
●
●
●
Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Available with lockable
weatherproof doors
Hose and cable brackets
Long-lasting maintenancefree 316L stainless steel
housing with limited
lifetime warranty
Copper bus bar with
ratings from 250 to 500A
Large removable
access panel for easy
maintenance and
installation
Backlit faceplate for easy
receptacle plug-in at night
6
6
342
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
Lighthouse–SS
6.5
Available Options
●
360° controlled 13 watt
fluorescent light with amber
lens for bug reduction
●
Digital electronic metering
for each side
Note: 20A GFI receptacles are
not to be used for shore power.
Powder-coated stainless steel
weatherproof doors that protect
receptacles and breakers
●
Lockable doors
●
Hose and cable bracket
Long-lasting maintenance-free
powder-coated stainless steel
housing with limited lifetime
warranty
●
High-speed Internet
connection (RJ-45)
for each side
●
Large removable access
panel for easy maintenance
and installation
●
●
6
Digital electronic metering
(one, two or three element
meters available)
20A/125V GFI receptacle
(max. of two GFI
receptacles per pedestal)
6
6
6
6
High-speed Internet
connection
Wireless remote metering
available for water and
electricity
Transient voltage surge
suppressor (TVSS) to
protect from voltage
surges, spikes or lightning
on the AC power line
(extends warranty on
internal parts to three
years)
Single or dual phone and/or
cable TV connections
Single or dual 3/4-inch
hose bibs with stainless
steel
Handles LED lighting
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Phone and Cable TV Connections
6
New Door
6
6
6
6
6
Copper Bus Bar with Ratings
from 250 to 500A
6
Backlit Faceplate to Aid
in Hooking Up at Night
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
343
6.5
Marina Power and Lighting Equipment
Catalog Number Selection
L D U 4 7 0 0 0 0 0 0 1 2 K M
6
6
Type
L = Lighthouse
S = LHSS
6
6
6
6
Metering Type
U = Unmetered
D = Digital electronic meters
(side one)
T = Digital electronic meters
(side two)
B = Digital electronic meters
(both sides)
R = Receptacles metered
individually
M = One meter socket
(100A)
N = Two meter socket
(100A each)
V = 200A meter socket
6
6
6
6
6
6
6
6
6
6
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
= None
= 20A GFI duplex
= 30A, 125V
= 50A, 125V
= 50A, 125/250V
= 100A, 208V
= 100A, 250V
= 100A, 277/480V
= 100A, 480V
R4S2
6
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
R3S2
6
R2S2
6
Sides and Receptacles
R1S2
6
R4S1
6
R2S1
Lighting and Lens Color
A = 7W light
Amber
B = Dual 7W light Amber
C = 9W light
Amber
D = 13W light
Amber
E = Dual 13W light Amber
F = No lighting
Amber
G = 7W light
Clear
H = Dual 7W light Clear
I = 9W light
Clear
J = 13W light
Clear
K = Dual 13W light Clear
L = No lighting
Clear
M = 7W light
Special
N = Dual 7W light Special
O = 9W light
Special
P = 13W light
Special
Q = Dual 13W light Special
R = No lighting
Special
S = 350 MA LED
Amber
T = 700 MA LED
Amber
U = 350 MA LED
Clear
V = 700 MA LED
Clear
W = 350 MA LED
Special
Y = 700 MA LED
Special
6
R1S1
6
R3S1
6
Power Pedestals
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
Water Option =0
=1
=2
= Single water meter
= Dual water meter
= Single meter, 2V
= 1 frost free
= 2 frost free
Extra Unmetered GFI
Receptacles 0 = None
1 =1
2 =2
Phone Cable TV and Internet Options
Phone
Cable TV
Internet
Jack
Jack
Option
A = 1
0
0
B = 1
0
1
C = 1
0
2
D = 1
1
0
E = 1
1
1
F = 1
1
2
G = 1
2
0
H = 1
2
1
I = 1
2
2
J = 2
0
0
K = 2
0
1
L = 2
0
2
M= 2
1
0
N = 2
1
1
O = 2
1
2
P = 2
2
0
Q = 2
2
1
R = 2
2
2
S = 0
2
2
T = 0
0
1
U = 0
0
2
V = 0
1
0
W= 0
1
1
X = 0
1
2
Y = 0
2
0
Z = 0
2
1
0 = 0
0
0
Bus
S = Single-phase 3/8-inch copper bus bar
F = Three-phase 3/8-inch copper bus bar
C = Single-phase 3/8-inch Canadian bus bar
T = Three-phase 3/8-inch Canadian bus bar
M = Single-phase 300 kcmil mechanical lug bus
Z = Three-phase 300 kcmil mechanical lug bus
L = Single-phase 350 kcmil mechanical lug bus
P = Three-phase 350 kcmil mechanical lug bus
N = Single-phase 1/4-inch copper bus bar
Q = Single-phase 1/4-inch split mechanical bus bar
Receptacle: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
Notes
Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
Quantity of 20A GFI duplex receptacles.
6
6
6
6
6
6
344
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Accessories
See Page 359.
6
Dimensions
6
Approximate Dimensions in Inches (mm)
6
Lighthouse–SS
6
6
6
6
6
6
6
6
6
6
40.00
(1016.0)
6
6
6
6
6
6
6
6
6
6
6
9.88
(251.0)
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
345
6.5
6
Power Pedestals
Marina Power and Lighting Equipment
Contents
Admiral–SS
Description
6
Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters. . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint. . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
6
6
6
6
6
6
6
6
6
335
338
342
347
348
348
349
353
357
363
364
365
366
367
370
373
374
6
6
6
Admiral–SS
6
Product Description
Features
Truly the flagship of our
unitized pedestal line, the
Admiral–SS possesses
amperage capabilities up to
500A and voltages of 480/277
three-phase, 120/240 singlephase and combinations of
these receptacles all in one
unit to serve nearly any size
Mega Yacht.
●
6
6
6
6
●
Heavy 316L stainless
steel housing that is
powder coated with a
polyester resin
Photocell controlled
13 watt fluorescent light
with clear lens that
provides 360 degrees
of lighting
Available Options
●
●
●
●
6
6
6
●
6
Dual phone and/or cable TV
connections
Four 100A receptacles
of any two voltage
combinations such as
277/480 three-phase,
120/208 three-phase or
120/240 single-phase
200A/480V receptacles
when the 100A 120/240V
receptacles are used, two
50A 120/240V receptacles
can also be provided for a
total of 500A
20A/125V GFI receptacle
(max. of two GFI
receptacles per pedestal)
Note: 20A GFI receptacles are not
to be used for shore power.
6
●
6
6
●
6
●
6
●
6
●
6
346
Single or dual Cat5
high-speed Internet
connections
Single or dual water
1/4-turn ball valves with
3/4-inch hose bibs and
stainless steel handles
Digital metering available
Wireless remote metering
available for water and
electricity
LED lighting
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Catalog Number Selection
6
A D U 4 7 0 0 0 0 0 0 1 2 K M
6
6
Type
A = Admiral–SS
Lighting and Lens Color
A = 7W light
Amber
B = Dual 7W light
Amber
C = 9W light
Amber
D = 13W light
Amber
E = Dual 13W light Amber
F = No lighting
Amber
G = 7W light
Clear
H = Dual 7W light
Clear
I = 9W light
Clear
J = 13W light
Clear
K = Dual 13W light Clear
L = No lighting
Clear
M = 7W light
Special
N = Dual 7W light
Special
O = 9W light
Special
P = 13W light
Special
Q = Dual 13W light Special
R = No lighting
Special
S = 350 MA LED
Amber
T = 700 MA LED
Amber
U = 350 MA LED
Clear
V = 700 MA LED
Clear
W = 350 MA LED
Special
Y = 700 MA LED
Special
R3S2
R4S2
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
None
20A GFI duplex
30A, 125V
50A, 125V
50A, 125/250V
100A, 208V
100A, 250V
100A, 277/480V
100A, 480V
R2S2
0
1
2
3
4
5
6
7
8
0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
R1S2
R4S1
R3S1
R2S1
Metering Type
U = Unmetered
D = Digital electronic meters
(side one)
T = Digital electronic meters
(side two)
B = Digital electronic meters
(both sides)
M = One meter socket
(100A)
N = Two meter socket
(100A each)
V = 200A meter socket
R1S1
Sides and Receptacles
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
Water Option =0
=1
=2
= Single water meter
= Dual water meter
= Single meter, 2V
Extra Unmetered GFI
Receptacles
0 = None
1 =1
2 =2
Phone Cable TV and Internet Options
Phone
Cable TV
Internet
Jack
Jack
Option A = 1
0
0
B = 1
0
1
C = 1
0
2
D = 1
1
0
E = 1
1
1
F = 1
1
2
G = 1
2
0
H = 1
2
1
I = 1
2
2
J = 2
0
0
K = 2
0
1
L = 2
0
2
M = 2
1
0
N = 2
1
1
O = 2
1
2
P = 2
2
0
Q = 2
2
1
R = 2
2
2
S = 0
2
2
T = 0
0
1
U = 0
0
2
V = 0
1
0
W= 0
1
1
X = 0
1
2
Y = 0
2
0
Z = 0
2
1
0 = 0
0
0
6
6
6
6
6
6
6
6
6
6
6
6
Bus
S = Single-phase 3/8-inch copper bus bar
F = Three-phase 3/8-inch copper bus bar
C = Single-phase 3/8-inch Canadian bus bar
T = Three-phase 3/8-inch Canadian bus bar
M = Single-phase 300 kcmil mechanical lug bus
Z = Three-phase 300 kcmil mechanical lug bus
L = Single-phase 350 kcmil mechanical lug bus
P = Three-phase 350 kcmil mechanical lug bus
N = Single-phase 1/4-inch copper bus bar
Q = Single-phase 1/4-inch split mechanical bus bar
D = Dual-phase bus bar
6
6
6
6
6
Receptacles: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R3S1 = Receptacle 3, Side 1
R4S1 = Receptacle 3, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
R3S2 = Receptacle 3, Side 2
R4S2 = Receptacle 3, Side 2
6
6
6
6
Notes
Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
Number represents the quantity of RJ-45 high-speed Internet jacks.
6
Internet option also available. Contact factory for details.
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
347
6.5
Power Pedestals
Marina Power and Lighting Equipment
6
Accessories
6
Dimensions
6
6
See Page 359.
Approximate Dimensions in Inches (mm)
Admiral–SS
Front
6
Side One
Back
Side Two
6
6
6
6
6
50.54
(1283.8)
6
6
6
6
6
6
6
6
6
2.00
(50.8)
Water
Access
6
6
6
14.00
(355.6)
6
240V
Electrical
Access
280V
Electrical
Access
10.00
(254.0)
6
CATV/INT.
Access
6
6
0.75
(19.1)
6
CATV/INT.
Access
12.50 (317.5)
Ø 0.62
(Ø 15.9)
14.00 (355.6)
6
Base Footprint
6
6
348
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Contents
Newport Harbor Mate
Description
Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate
Available Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection. . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint . . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels. . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
335
338
342
346
350
351
352
352
353
357
363
364
365
366
367
370
373
374
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Newport Harbor Mate
Product Description
Five years of development
and 30 prototype models
have yielded this unit the
most innovative mini-power
center available. Host to a
variety of electrical services,
contained in a compact yet
strong housing, the Newport
Harbor Mate is packed with
features.
Features, Benefits
and Functions
●
●
●
●
6
Tough and durable resin
housing with UV inhibitor
for lasting finish
Photocell controlled 7 and
9 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Designed to mount
on a dock box, piling or
stainless steel stand
Copper bus bar with a
maximum rating of 140A
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
349
6.5
6
6
6
6
6
Power Pedestals
Marina Power and Lighting Equipment
Newport Harbor Mate (Shown with Optional Stand)
●
Tough and durable resin housing
with UV inhibitor for lasting finish
●
Available with single, dual or
combo of 30 or 50A receptacles
20A/125V GFI receptacle
Phone, cable TV, high-speed
Internet connections
Digital electronic meter
6
6
Photocell controlled 7 watt
fluorescent light with amber
lens for bug reduction
●
6
6
6
6
Available with single, dual
or combination of 30A or
50A receptacles
20A/125V GFI receptacle
(max. of two GFI
receptacles per pedestal)
Note: 20A GFI receptacles are
not to be used for shore power.
●
Lockable weatherproof door that
protects receptacles and breakers
6
Available Options
●
●
Single or dual phone, cable
TV, high-speed Internet
connections
Electronic metering
(one or two element
meters available)
316L stainless steel stand
LED lighting
Single or dual 1/2-turn brass ball
valve with 3/4-inch hose bibs
Stainless steel stand
Designed to mount on a dock
box, piling, wall or optional
stand (shown in photo)
6
6
6
6
6
6
6
6
Mounting Option
Backlit Faceplate
6
6
6
6
6
6
6
6
6
6
350
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Catalog Number Selection
6
N A Y B U 4 3 0 1 1 2 W M
Type
N = NP Harbor Mate
C = NP Camp Mate
Lighting and Lens Color
A = 7W light
Amber
C = 9W light
Amber
F = No lighting
Amber
G = 7W light
Clear
I = 9W light
Clear
L = No lighting
Clear
M = 7W light
Special
O = 9W light
Special
R = No lighting
Special
S = 350 MA LED
Amber
T = 700 MA LED
Amber
U = 350 MA LED
Clear
V = 700 MA LED
Clear
W = 350 MA LED
Special
Y = 700 MA LED
Special
Photocell
Y = Yes
N = No
Lighting Protection
B = Breaker protected
F = Fuse protected
Metering Type U = Unmetered
D = Digital electronic meters
R = Receptacles metered
individually
Sides and
Receptacles
R1S1 R2S1 R3S1
0
0
0
1
1
1
2
2
3
3
4
4
0 = None
1 = 20A GFI duplex
2 = 30A, 125V
3 = 50A, 125V
4 = 50A, 125/250V
Stand
0 =0
1 =1
6
6
Bus
S = Single-phase 1/4-inch copper bus bar
F = Three-phase 1/4-inch copper bus bar
C = Single-phase 1/4-inch Canadian bus bar
M = Mechanical lug 2/0
Q = Single-phase 1/4-inch split mechanical
bus bar (with stand ONLY)
A = 1/4-inch Canadian mechanical
6
6
6
Water
Option 0 =0
1 =1
2 =2
6
6
Hard Wired
Breakers
6
S1
0 = None
2 = 20A, two-pole
3 = 30A
6
6
6
Phone Cable TV and Internet Options
Phone Jack
Cable TV Jack
Internet Option
A =
1
0
0
B =
1
0
1
C =
1
0
2
D =
1
1
0
E =
1
1
1 (Camp Mate only)
T =
0
0
1
V =
0
1
0
W=
0
1
1
0 =
0
0
0
6
6
6
6
Receptacles: R1 = Receptacle 1
R2 = Receptacle 2
6
Notes
20A GFIs not metered.
Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs (with stand only).
6
6
6
6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
351
6.5
6
Accessories
6
Dimensions
6
6
6
Power Pedestals
Marina Power and Lighting Equipment
See Page 359.
Approximate Dimensions in Inches (mm)
Newport Harbor Mate
0.12
(3.2)
0.12
(3.2)
9.18 (233.0)
9.18 (233.0)
6
6
10.38
(263.7)
10.38
(263.7)
6
6
7.44
(189.1)
10.52 (267.2)
6
7.44
(189.1)
10.52 (267.2)
6
15.28
(388.0)
6
14.53
(369.0)
6
14.53
(369.0)
13.63
(346.2)
12.88
(327.2)
6
6
6
4º
4º
10.38 (263.7)
10.38 (263.7)
9.59 (243.6)
6
6
6
6
1.54
(39.1) 4.02
(102.2)
2.37
(60.3)
6
1.68
(42.7)
6
6
1.68
(42.7)
3.40
(86.4)
6.70
(170.2)
1.54
(39.1) 4.02
(102.2)
2.37
(60.3)
3.40
(86.4)
6.70
(170.2)
Newport Redesign
Newport Redesign With Meters
6
6
6
6
6
6
6
352
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Contents
Hatteras Light
Description
Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light
Available Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection. . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint . . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels. . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
335
338
342
346
349
354
355
356
356
357
363
364
365
366
367
370
373
374
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Hatteras Light
Product Description
The Hatteras® Light is an
elegant and low cost
alternative to the Lighthouse.
It uses the same 360 degree
light assembly as the
Lighthouse, yet is only
30 inches tall. Thousands
of these attractive pedestals
are found not only in marinas,
but also around pools, deck
areas, boardwalks and
landscape areas. The housing
will never rust or corrode and
comes with a limited lifetime
warranty. This unit is popular
for smaller slips at marinas
with the Lighthouse and for
private docks.
Features, Benefits
and Functions
●
●
●
●
6
Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Circuit breakers
Heavy resin housing with
a two-part polyurethane
coating for a UV resistant,
long-lasting finish
Copper bus bar with a
maximum rating of 140A
6
6
6
6
6
6
6
6
Note: Wireless remote reading
of electronic kilowatt meters.
6
Note: Clear lens.
6
Note: Custom paint color.
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
353
6.5
6
Power Pedestals
Marina Power and Lighting Equipment
Available Options
Hatteras Light
360° controlled 13 watt
fluorescent light with amber
lens for bug reduction
6
6
Receptacle configurations
available:
Side 1: 30A, 50A
Side 2: 30A, N/A
Note: Custom configurations
also available
6
6
●
Note: 20A GFI receptacles are
not to be used for shore power.
●
●
Digital electronic metering
6
●
6
Circuit breakers
6
Phone, cable TV,
high-speed Internet
connections
6
20A/125V GFI receptacle
(max. of two GFI
receptacles per pedestal)
●
Digital electronic metering
(one or two element meter
available)
Single or dual phone, cable
TV, high-speed Internet
connections
Single or dual 1/2-inch or
3/4-inch silcock with
stainless steel handles
LED lighting
1/4-inch resin housing with a
two-part polyurethane coating
for a UV resistant, long-lasting
finish
6
6
6
1/2-turn brass ball valve and
3/4-inch hose bib
6
6
6
6
6
6
6
Copper Bus Bar with Ratings
up to 140A
6
20A/125A GFI Receptacle
6
6
6
6
6
6
Faceplate
6
6
6
6
354
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Catalog Number Selection
6
H D Y B D 4 7 0 1 2 A M
Type
H = Hatteras Light
R = Park Light
Lighting and Lens Color
A = 7W light
Amber
B = Dual 7W light Amber
C = 9W light
Amber
D = 13W light
Amber
E = Dual 13W light Amber
F = No lighting
Amber
G = 7W light
Clear
H = Dual 7W light Clear
I = 9W light
Clear
J = 13W light
Clear
K = Dual 13W light Clear
L = No lighting
Clear
M = 7W light
Special
N = Dual 7W light Special
O = 9W light
Special
P = 13W light
Special
Q = Dual 13W light Special
R = No lighting
Special
S = 350 MA LED
Amber
T = 700 MA LED
Amber
U = 350 MA LED
Clear
V = 700 MA LED
Clear
W = 350 MA LED
Special
Y = 700 MA LED
Special
6
Photocell
Y = Yes
N = No
Lighting Protection
B = Breaker protected
F = Fuse protected
Metering Type U = Unmetered
D = Digital electronic meters
R = Receptacles metered
individually
Sides and
Receptacles
R1S1 R2S1 R1S2
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
0 = None
1 = 20A GFI duplex
2 = 30A, 125V
3 = 50A, 125V
4 = 50A, 125/250V
6
Bus
S = Single-phase 1/4-inch copper bus bar
F = Three-phase 1/4-inch copper bus bar
C = Single-phase 1/4-inch Canadian bus bar
M = Mechanical lug 2/0 A = 1/4-inch Canadian mechanical
Water Option 0 =0
1 = 1 (1/2-inch)
2 = 2 (1/2-inch)
3 = 1 (3/4-inch)
4 = 2 (3/4-inch)
Hard Wired
Breakers
S1
0 = None
2 = 20A, two-pole
3 = 30A
6
6
6
Phone Cable TV and Internet Options
Phone
Cable TV
Internet
Jack
Jack
Option
A= 1
0
0
B= 1
0
1
C = 1
0
2
D= 1
1
0
E = 1
1
1
F = 1
1
2
G= 1
2
0
H= 1
2
1
I = 1
2
2
J = 2
0
0
M= 2
1
0
P = 2
2
0
S = 0
2
2
T = 0
0
1
U= 0
0
2
V = 0
1
0
W= 0
1
1
X = 0
1
2
Y = 0
2
0
Z = 0
2
1
6
6
6
6
6
6
6
6
6
Receptacles: R1 = Receptacle 1
R2 = Receptacle 2
6
Notes
20A GFIs not metered.
Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
Wire size #2/0 kcmil or less.
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
355
6.5
6
Accessories
6
Dimensions
6
6
Power Pedestals
Marina Power and Lighting Equipment
See Page 359.
Approximate Dimensions in Inches (mm)
Hatteras
6
6
6
6
6
6
Bus Bar Access Top Removed
6
Inside Top
6
13.39
(340.2)
6
6
6
6
6
6
6
6
30.98
(786.9)
6
6
6
6
6
6
6
6
6
6
356
7.90 (200.7)
7.90 (200.7)
Side View
Front View
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Contents
Firehouse
Description
Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse
Available Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection. . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint . . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels. . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
335
338
342
346
349
353
358
358
359
362
363
364
365
366
367
370
373
374
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Firehouse
Product Description
Created as a complete
solution for fire and rescue
needs, this pedestal features
fire extinguisher storage and
a mounted alarm strobe light
and siren, as well as an
optional life ring. This unit
is well equipped for any
marina emergency. The alarm
strobe light and siren can be
automatically activated when
the door is open or optional
life ring is removed.
Features, Benefits
and Functions
●
●
●
●
●
6
Firehouse
Alarm strobe light and
siren: automatically
activated when door is
open or optional life ring
is removed
Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
10 lb ABC Type fire
extinguisher
316L stainless steel
polyester powder-coated
housing
Polycarbonate top
assembly
6
High-visibility alarm
strobe light and
warning siren
6
Photocell controlled
energy efficient 13 watt
fluorescent light with
amber lens for bug
reduction
6
6
Stainless steel housing with
oven-baked enamel finish
with a polycarbonate base
and top
6
Remote control unit can
automatically call select
services via a four
channel transmitter:
Medical emergency
Fire emergency
Police emergency
Optional general
emergency
6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
357
6.5
6
Power Pedestals
Marina Power and Lighting Equipment
Available Options
●
24-inch life ring
20 lb ABC Type fire
extinguisher available
6
●
6
Catalog Number Selection
F A Y A E N
6
6
Type
F = Firehouse
6
Photocell
Y = Yes
N = No
6
24-Inch Life Ring
R = Include life ring
N = No life ring
Alarm/Strobe
A = Include alarm/strobe
N = No alarm/strobe
6
6
A
B
C
D
E
F
G
H
6
6
6
= 7W light
= Dual 7W light
= 9W light
= 13W light
= Dual 13W light
= No lighting
= 7W light
= Dual 7W light
Amber
Amber
Amber
Amber
Amber
Amber
Clear
Clear
Fire Extinguisher
E = Include 10 lb extinguisher
N = No extinguisher
X = Include 20 lb extinguisher
Lighting and Lens Color
I = 9W light
Clear
J = 13W light
Clear
K = Dual 13W light Clear
L = No lighting
Clear
M = 7W light
Special
N = Dual 7W light Special
O = 9W light
Special
P = 13W light
Special
Q = Dual 13W light
R = No lighting
S = 350 MA LED
T = 700 MA LED
U = 350 MA LED
V = 700 MA LED
W = 350 MA LED
Y = 700 MA LED
Special
Special
Amber
Amber
Clear
Clear
Special
Special
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
358
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
6.5
Power Pedestals
Marina Power and Lighting Equipment
Accessories
6
Accessories for Custom Design Marina Products, Resin and Stainless Steel Pedestals and Power Products
Replacement Parts Catalog Numbers
Catalog
Number
Description
6
Replacement Parts Catalog Numbers, continued
Receptacles
20A GFCI duplex
MPL3038
30A 125V twistlock
MPL3039
50A 125V twistlock
MPL3040
50A 125/250V twistlock
MPL3045
100A 120/240V pin and sleeve
MPL4100R12W
100A 120/208V pin and sleeve
MPL5100R9W
100A 480V four-wire pin and sleeve
MPL4100R7W
6
Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS, Hatteras, Park Light, continued
20A GFCI receptacle external cover set
MPL1101
30A receptacle external cover set
MPL1102
50A receptacle external cover set
MPL1105
Single-pole external breaker cover set
MPL11061
Two-pole external breaker cover set
MPL11062
Three-pole external breaker cover set
MPL11063
100 A 480V five-wire pin and sleeve
MPL5100R7W
Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS
200A 277/480V pin and sleeve (Russellstoll®)
MPL4200R7W
Lighthouse/Powerhouse pedestal main housing
MPL6006
30A 125V RV
RV3042
Lighthouse–SS/Powerhouse–SS pedestal main housing
MPL6006S
50A 125/250V RV
RV3043
Lighthouse/Powerhouse main door
MPL6007
Circuit Breakers
6
Catalog
Number
Description
6
6
6
6
6
6
6
Lighthouse–SS/Powerhouse–SS main door
MPL6007S
20A 125V single-pole
QCF1020
Lighthouse/Powerhouse spring closure
MPL1099
20A 125V single-pole GFCI
QCGF1020
Lighthouse Powerhouse top isolation plate
MPL6012
30A 125V single-pole
QCF1030
Lighthouse/Lighthouse–SS breaker plate
MPL1141
30A 125V single-pole GFCI
QCGF1030
Powerhouse/Powerhouse–SS breaker plate
RV1112
50A 125V single-pole
QCF1050
6
QCF2020
Lighthouse/Lighthouse–SS/Powerhouse/
Powerhouse–SS Hose and cable brackets
MPL1087
20A 125/250V two-pole
20A 125/250V two-pole GFCI
QCGF2020
Lighthouse/Powerhouse stainless steel hinge
MPL1088
6
30A 125/250V two-pole
QCF2030
Lighthouse/Powerhouse complete pedestal
base with bus bar assembly
MPL6004A
30A 125/250V two-pole GFCI
QCGF2030
MPL6004FA
50A 125/250V two-pole
QCF2050
Lighthouse/Powerhouse complete pedestal base with three-phase
bus bar assembly
50A 125/250V two-pole GFCI
QCGF2050
Lighthouse/Powerhouse pedestal base without bus bars
MPL6004
60A 125/250V two-pole
QCF2060
Lighthouse/Powerhouse aluminum blank access panel
MPL5500
100A 125/250V two-pole
GHC2100D
MPL1140A
100A 120/208V three-pole
GHC3100D
Lighthouse/Lighthouse–SS/Powerhouse/
Powerhouse–SS complete bus bar assembly
Lighthouse/Lighthouse–SS/Powerhouse/Powerhouse–SS complete
three-phase bus bar assembly
MPL1140FA
Copper bus bar with nuts and washers
MPL3471
20A GFCI—00 amber resin faceplate
MPL1120
30A—20 GFCI amber resin faceplate
MPL1121
30–50A amber resin faceplate
MPL1122
30–30A amber resin faceplate
MPL1127
30–00A amber resin faceplate
MPL1129
50–50A amber resin faceplate
MPL1123
50A—20 GFCI amber resin faceplate
MPL1124
20 GFCI—20 GFCI amber resin faceplate
MPL1125
00–00 amber resin faceplate
MPL1126
200A 277/480V three-pole
JT2200FA
Fluorescent Light Assembly
13 watt 120V 60 Hz ballast
MPL2400
7 watt 120V 60 Hz ballast
MPL2401
13 watt socket
MPL3079
7 watt socket
MPL3077
13 watt fluorescent bulb
MPL3018
7 watt fluorescent bulb
MPL3019
Photocell
MPL3044
Photocell nuts
MPL3034
Lighthouse in-line fuse
MPL3026
Lighthouse in-line fuse holder
MPL3027
6
6
6
50A—00 amber resin faceplate
MPL1128
Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS, Hatteras, Park Light
100A faceplate
MPL1142
Top with complete light and lens assembly
MPL6003A
20A GFCI—00 amber resin faceplate assembly with breakers
MPL1120A
Top with complete light and lens assembly—fused
MPL6003FA
30A—20 GFCI amber resin faceplate assembly with breakers
MPL1121A
Top only
MPL6003
30–50A amber resin faceplate assembly with breakers
MPL1122A
Amber lens
MPL6005
Clear lens
MPL6008
Volume 1—Residential and Light Commercial CA08100002E—December 2010
6
6
6
6
6
6
6
6
6
6
6
6
6
6
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
359
6.5
6
6
6
Power Pedestals
Marina Power and Lighting Equipment
Replacement Parts Catalog Numbers, continued
Catalog
Number
Description
MPL1127A
6
50–50A amber resin faceplate assembly with breakers
MPL1123A
50A—20 GFCI amber resin faceplate assembly with breakers
MPL1124A
6
20 GFCI—20 GFCI amber resin faceplate assembly with breakers
MPL1125A
50A—00 amber resin faceplate assembly with breakers
MPL1128A
30–00A faceplate assembly with breakers
MPL1129A
100A faceplate assembly with breakers
MPL1142A
Powerhouse 30–50 receptacle plate
RV1143
6
Powerhouse (30A—00) receptacle plate
RV11433
Powerhouse (50A—00) receptacle plate
RV11435
6
Powerhouse breaker plate
RV1112
6
6
6
6
6
6
6
6
Phone, Cable, Internet Assemblies
MPL17A2 Single element, 14-pin quick disconnect (with CTs)
MPL17A2 Dual element, 14-pin quick disconnect (no CTs)
MPL17B1
Dual element, 14-pin quick disconnect (with CTs)
MPL17B2 Dual element, 14-pin quick disconnect (with CTs)
MPL17B2 Three element, 14-pin quick disconnect (no CTs)
MPL17C1
Three element, 14-pin quick disconnect (with CTs)
MPL17C2 Three element, 14-pin quick disconnect (with CTs)
MPL17C2 Single element coil transformers (CTs)
MPL30321 Single element coil transformers (CTs)
MPL30321 Dual element coil transformers (CTs)
MPL30322 Dual element coil transformers (CTs)
MPL30322 Three element coil transformers (CTs)
MPL30323 Three element coil transformers (CTs)
MPL30323 Lighthouse–SS/Powerhouse–SS/Hatteras Light/Park Light complete
phone and cable assembly
MPL1119/RV1119
Hatteras Light/Park Light complete phone and cable assembly
MPL1119
Counter (large—old style)
MPL3022
Newport Harbor Mate/Camp Mate phone and cable insert assembly
MPL1115/RV1115
Counter (small—new style)
MPL3021
Lighthouse/Powerhouse access plates with dual Internet jacks
MPL5501
Hatteras Light (Marina) and Park Light (RV) Coax cable TV FCF female adpt. with lugnut and washer
MPL1086
Pedestal main housing
MPL6002
MPL3059
Copper bus bar with nuts and washers
MPL3468
MPL3037
Complete bus bar assembly
MPL1108A
RV3060
Complete three-phase bus bar assembly
MPL1108FA
20A GFCI external cover door
MPL1101
30A external cover door
MPL1102
50A external cover door
MPL1105
Light fuse
MPL3026
Fuse holder
MPL3027
Mounting feet (set of four)
MPL7004
RJ45 CAT5e high-speed internet jack
Marine phone receptacle
RJ12 CAT3 phone jack
Water Assemblies
Newport Harbor Mate/Newport Camp Mate water manifold
assembly (dual 3/4-inch hose bibs with 1/4-turn ball valves)
MPL11C
3/4-inch hose adapter
MPL7030
6
Lighthouse/Powerhouse water mounting plate
with mounting brackets
MPL1132
6
Hatteras Light/Park Light aluminum water mounting plate
MPL6584
1/2-inch brass silcock (hose bib)
MPL7014
6
3/4-inch stainless steel silcock (hose bib)
MPL5271
3/4-inch brass ball valve
MPL7021
Watts 3/4-inch backflow preventer
MPL7015
6
MPL17A1
Single element, 14-pin quick disconnect (with CTs)
MPL1114/RV1114
MPL11A
6
Single element, 14-pin quick disconnect (no CTs)
Lighthouse/Powerhouse complete phone and cable assembly
Lighthouse/Powerhouse complete water manifold assembly
(dual 3/4-inch hose bibs with 1/4-turn ball valves)
6
Catalog
Number
Description
Digital Electronic Meters
Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS, continued
30–30A amber resin faceplate assembly with breakers
6
Replacement Parts Catalog Numbers, continued
Notes
Lighthouse, Lighthouse–SS, Powerhouse, Powerhouse–SS.
Hatteras Light, Park Light, Newport Camp Mate, Newport Harbor Mate.
Please contact factory to determine configurations for replacement housing.
6
6
6
6
6
6
6
6
360
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Replacement Parts Catalog Numbers, continued
6
Catalog
Number
Description
6
Newport Harbor Mate (MARINA)
and Camp Mate (RV)
Amber lens—three-piece
MPL1117
Clear lens—three-piece
MPL1109
Main housing
MPL6000
Main door
MPL6001
30–30A faceplate MPL1135
30–50A faceplate MPL1136
50–50A faceplate MPL1137
50A–00 faceplate MPL1138
30A–00 faceplate MPL1139
30–30A faceplate assembly with breakers MPL1135A
30–30–20 GFI faceplate assembly MPL1135G/RV1135G
30–50A faceplate assembly with breakers MPL1136A
30–50–20 GFI faceplate assembly MPL1136G/RV1136G
50–50A faceplate assembly with breakers MPL1137A
50–50–20 GFI faceplate assembly MPL1137G/RV1137G
50A–00 faceplate assembly with breakers MPL1138A
50–20 GFI faceplate assembly MPL1138G/RV1138G
30A–00 faceplate assembly with breakers MPL1139A
30–20 GFI faceplate assembly
6
6
6
6
6
6
6
6
6
6
6
MPL1139G/RV1139G
Mounting brackets
MPL7005
36-inch stainless steel stand
MPL5506
Copper bus bar with nuts and washers
MPL3468
Complete bus bar assembly
MPL1108A
Complete three-phase bus bar assembly
MPL1108FA
6
6
6
6
Firehouse (Marina and RV)
Red strobe light/siren
MPL3020
Firehouse top with lighting assembly and strobe
MPLFH6003A
Light fuse
MPL3029
Fuse holder
MPL3028
Door
MPL6013
24-inch life ring
MPL4201
Life ring bracket
MPL4201B
Blank access panel
MPL6015
Door/life ring switch (pre-2004)
MPL3030
Door/life ring switch (new)
MPL3050
Door hasp
MPL3950
Bus bar (double barrel terminal block)
MPL3751
10-lb ABC Type fire extinguisher
MPL8025
20-lb ABC Type fire extinguisher
MPL8025X
6
6
6
6
6
6
6
6
6
Note
For custom faceplates to include phone/cable or other accessories,
please contact Eaton’s Marina Power & Lighting facility at 1-800-723-8009.
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
361
6.5
6
6
Power Pedestals
Marina Power and Lighting Equipment
Dimensions
Approximate Dimensions in Inches (mm)
Firehouse–SS
6
6
6
6
6
6
6
6
6
6
6
43.50
(1104.9)
6
6
6
6
6
6
6
6
6
6
6
9.87
(250.6)
6
6
6
6
6
6
362
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
6.5
Power Pedestals
Marina Power and Lighting Equipment
Contents
Smart Start
Description
Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint . . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels. . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
335
338
342
346
349
353
357
364
365
366
367
370
373
374
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Smart Start
Product Description
Features
If you have transient boat
slips, Eaton CorporationMarina Power and Lighting
has developed their newest
product for your situation.
●
The new “Smart Start”
pedestal is activated by the
swipe of a credit card. A kiosk
will be centrally located at the
marina and will control up to
32 power pedestals. When a
boater wants to use a slip,
they will enter the slip
number and amount of time
they would like and will then
be asked to swipe a card in
order to activate the pedestal.
Once the chosen time is up,
the pedestal will shut down.
No more free power!
●
●
Lighted 316L stainless
steel kiosk enclosure
Programmable slip
time blocks
Programmable slip rates
printable receipts
Standards and Certifications
●
UL listing pending
Dimensions
Approximate Dimensions in
Inches (mm)
Smart Start
Height
14.15 (359.4)
Depth
14.24 (361.9)
6
6
60.05 (1525.3)
Width
6
6
6
6
6
6
6
6
The “Smart Start” pedestal
will not only prevent transient
boaters from stealing power,
but it will also eliminate the
need for 24-hour monitoring
of the slips. Boaters will be
able to come in at any time
of the day and activate a
pedestal.
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
363
6.5
6
Power Pedestals
Marina Power and Lighting Equipment
Contents
Marina Power and Lighting Equipment
Description
6
6
6
6
6
6
6
6
Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner
Digital Electronic Kilowatthour Meters. . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint. . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
Mariner
335
338
342
346
349
353
357
363
365
366
367
370
373
374
6
6
6
6
6
Mariner
6
Product Description
Features
The Mariner is a lighting
bollard that can stand from
1.5 to 4 feet tall and can be
used in various applications
from marina docks, to
landscaped areas, golf
courses and beyond. The
Mariner will have a lifetime
warranty on the engineered
resin housing that will
withstand the harsh marine
and land environments from
Alaska to the tropics.
●
6
6
6
6
6
6
6
●
●
●
●
Dimensions
Can be configured with a
7 watt, 9 watt or 13 watt
fluorescent bulb
Mounting base and painted
pole supplied for desired
height
Limited lifetime warranty
on engineered resin
housing
Custom colors available
Side-mounted option
Approximate Dimensions in
Inches (mm)
Mariner
7 watt
14.15 (359.4)
9 watt/13 watt 14.24 (361.9)
Mounting Base and Pole
1.5 feet–4 feet
Catalog Number Selection
M 5 A R 18
6
6
Type
M = Mariner
6
6
Bulb Wattage
5 = 5W
7 = 7W
9 = 9W
3 = 13W
1 = 50 MA LED
Color Lens
A = Amber
C = Clear
S = Special
Color
W = White
R = Blue
B = Black
D = Dark green
S = Special
Stand Height
18 = 18-inch
24 = 24-inch
36 = 36-inch
48 = 48-inch
6
6
6
6
364
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
6.5
Power Pedestals
Marina Power and Lighting Equipment
Contents
Digital Electronic Kilowatt Hour Meters
Description
Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters
Distribution Equipment—Ground Fault Monitor . . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint . . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels. . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
335
338
342
346
349
353
357
363
364
366
367
370
373
374
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Digital Electronic Kilowatthour Meters
Product Description
Features
Available Options
Using the latest surface
mount technology, Eaton
manufactures a digital
electronic kilowatthour meter
that exceeds the +/– 2%
accuracy required by ANSI
(American National Standards
Institute) C-12.1 and is
approved by the state of
California at +/– 1% over the
full range of 0–100A from a
0.5–1 power factor and is
available for both single- and
three-phase applications.
Our meter is designed to
be user friendly in that all
connections from external
sources and the meter output
are through one 14-pin locking
connector. This feature
eliminates many common
problems, such as reverse
line polarity and improper coil
polarity. Simple LEDs, both
red and green, indicate line
and load condition and the
pulsed LED indicates the rate
of power consumption.
●
The meter drives an electromechanical counter that
requires a 12V pulse each
tenth of a kilowatthour,
providing 10 pulses per
kilowatt used. The meter
output can be hard wired or
connected to a transmitter
in the pedestal for wireless
transmission to a receiver
displaying the output on a
PC for direct billing of up to
1,000 individual customers.
Wireless System
All of our meters are “wireless
capable” to allow for wireless
meter reading. This technology
enables the marina or RV park
to get meter readings from
one central location rather
than visiting every site to
read the counters.
●
●
●
●
Product Selection
6
200A (SS only)
Lockable hasp
Ringless (SS only)
Five jaw
Seven jaw (SS only)
6
6
6
6
One Element Meter
6
6
6
6
Two Element Meter
6
6
6
Meter Socket Capabilities
Meter sockets are available
on the Lighthouse and
Lighthouse–SS.
Standard
●
Four jaw
●
Ring-type
●
100A
Volume 1—Residential and Light Commercial CA08100002E—December 2010
6
6
Three Element Meter
6
6
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
365
6.5
6
Power Pedestals
Marina Power and Lighting Equipment
Contents
Ground Fault Monitor
Description
6
Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters. . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor
Distribution Equipment—Mega Yacht Powerpoint. . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
6
6
6
6
6
6
6
335
338
342
346
349
353
357
363
364
365
367
370
373
374
6
6
6
6
6
Distribution Equipment—Ground Fault Monitor
6
Product Description
Features
Our ground fault monitoring
systems are designed to
detect fault currents in the
AC shore power system that
are too low to trip a circuit
breaker. The ground fault
monitor helps reduce the risk
of injury or property damage
that may result from stray
fault currents. Our ground
fault monitoring system
provides information to the
maintenance staff on the
overall condition of the AC
electrical system. The ground
fault monitoring system
operates 24 hours a day and
can be monitored by nontechnical personnel.
●
6
6
6
6
6
6
6
6
6
6
6
6
●
●
●
Adjustable trip level 10 mA
to 10A
Current transformers up to
8 1/4-inch diameter
Visual and/or audible alarm
Housing of fiberglass or
powder-coated stainless
steel available
Standards and Certifications
●
UL listed current
transformers
Power Guard
The ground fault monitor
detects ground fault currents
by means of current
transformers (CT), which are
placed around main or branch
circuits. If a ground fault
occurs, the CT will detect the
amount of fault current and
send a signal to the ground
fault monitoring device where
the amount of fault current is
displayed with the faulty
circuit identified. The
detected fault can either
activate an indicator alarm or
disconnect the faulted circuit.
6
6
6
366
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Contents
Marina Power and Lighting Equipment
Description
Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels. . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
335
338
342
346
349
353
357
363
364
365
366
368
369
370
373
374
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Distribution Equipment—Mega Yacht Powerpoint
Product Description
Features
From the company that is
known for its high-quality
innovations, Eaton is the only
company to offer a selfcontained dual-phase mega
yacht unit. Made out of longlasting stainless steel, this
mega yacht unit has a
copper-wound, low-noise
transformer that is double
insulated and epoxy
overcoated.The mega yacht
unit delivers both singlephase and three-phase power
to serve most mega yachts.
Helping to keep your marina
environment tranquil, the
mega yacht unit has a
low-noise, highly efficient
transformer that has isolation
mounts to ensure a very
quiet operation.
●
●
●
●
●
Thermostatically controlled
fans in transformer
compartment for cooling
Heavy stainless steel
(316L) cabinet with a
polyester powder coating
Ventilated sun shields to
help unit run cooler in
tropical climates
Limited lifetime warranty
on housing
Two or three light 13 watt
photocell controlled
fluorescent lights on
the sun shield for optimal
night lighting
Available Options
●
●
●
●
●
●
●
●
●
●
200A–480V three-phase
receptacles
100% rated breakers
Hard wiring bus bars for
all voltages with breaker
protection
Two 3/4 inch water outlets
with a water meter
Two phone, two CATV
and two CAT5 high-speed
Internet connections
Digital electronic meters
on all receptacles
Primary breaker
Two 480V delta or wye
125A three-phase
receptacles (IEC)
Two 120/208V 100A threephase receptacles (IEC)
Two 120/240V 100A singlephase receptacles (IEC)
●
●
●
●
●
●
●
●
Up to four 50A 120/240V
locking receptacles
(NEMA)
Up to four 30A 120V
locking receptacles
(NEMA)
Wireless remote metering
for electric and water
20A GFI receptacle
Primary side 480V
maximum 600A
Secondary side singlephase 120/240V maximum
100 kVA
Secondary side threephase 120/208V maximum
125 kVA
Fire extinguisher—10 or
20 lbs
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
367
6.5
Power Pedestals
Marina Power and Lighting Equipment
6
Wiring Diagram
6
Powerpoint
6
120/240 V Single-Phase Supply
120/240 V Three-Phase Supply
277/480 V Supply
from Utility
480 V
3Ø 3-Pole
Main
Breaker
1
6
Dual-Phase Primary
Transformer 480 V
6
A
6
A
6
O
B
A
6
B
N
N
6
N
120/240 V
100 A 1Ø
2-Pole
Breaker
120/240 V
100 A 1Ø
2-Pole
Breaker
2
3
B
To 480 V
Service
1 2 3
1 2 3
1 2 3
3 Ø, 277/480 V
Supply from
Main Breaker
3 Ø, 277/480 V
Supply from
Main Breaker
3 Ø, 277/480 V
Supply from
Main Breaker
120/208 V
100 A 3Ø
3-Pole
Breaker
120/208 V
100 A 3Ø
3-Pole
Breaker
120/208 V
100 A 3Ø
3-Pole
Breaker
480 V
100 A 3Ø
3-Pole
Breaker
480 V
100 A 3Ø
3-Pole
Breaker
480 V
100 A 3Ø
3-Pole
Breaker
N
N
CT for
Electronic
Meter (Typ.)
N
N
N
G
6
6
G
G
G
G
100 A Hard
Wire Buss
120/480 V
G
G
200 A Hard Wire Buss
277/480 V
(Ground & Neutral
from Utility Supply)
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
368
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Dimensions
6
Approximate Dimensions in Inches (mm)
6
Powerpoint Unit
6
6
6
6
6
6
Top With Solar Shield
6
31.00
(787.4)
46.00 (1168.4)
6
6
6
48.54
(1232.9)
6
6
6
6
Left Side
Front
6
Right Side
6
26.00
(660.4)
6
6
26.00
(660.4)
6
6
Ø 0.50
(Ø 12.7)
6
Base
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
369
6.5
6
Power Pedestals
Marina Power and Lighting Equipment
Contents
Substations
Description
6
6
6
6
6
6
6
6
Double Panel Substation
6
6
6
Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters. . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint. . . . . . . .
Distribution Equipment—Substations
Features, Benefits and Functions . . . . . . . . . . . . . . . . . .
Available Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
335
338
342
346
349
353
357
363
364
365
366
367
371
372
372
372
373
374
6
6
Distribution Equipment—Substations
6
Product Description
Application Description
The introduction of
substations into the marina
and recreational vehicle
market allows Eaton to be
your complete marina and RV
park electrical products
supplier. We are able to
assist in the design and
layout of your marina or RV
park electrical system from
the primary service provider,
to your power pedestal.
Our substations are designed
for any coastal or inland
environment and are
constructed of powdercoated stainless steel NEMA
3R housing cabinets. All
substation cabinets come
with our limited lifetime
warranty. All of our
substations use Eaton’s
panels and circuit breakers
providing our customers the
utmost in circuit protection
and quality.
The aluminum and Galvaneal
cabinets are recommended
for inland applications.
The substations can be
configured with 50–330 kVA
single-phase or three-phase
copper wound transformers
and up to 20 single-phase or
12 three-phase branch
breakers. An optional threesided double-wall cabinet is
available that provides air
flow between the panels. All
substations come standard
with temperature controlled
cooling fans.
6
6
6
6
6
6
6
6
6
6
6
Product Selection Guide
Panel and Transformer
Combinations
Panel
Transformer
Single-Phase
200A
50 kVA
300A
75 kVA
400A
100 kVA
600A
150 kVA
700A
167.5 kVA
800A
200 kVA
1000A
250 kVA
1200A
330 kVA
Three-Phase
100A
45 kVA
200A
75 kVA
300A
112.5 kVA
400A
150 kVA
600A
225 kVA
800A
300 kVA
6
6
6
6
370
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Features, Benefits
and Functions
●
●
●
●
Limited lifetime warranty
on the housing
All stainless steel
hardware
Temperature controlled
cooling fans in the
transformer and circuit
breaker compartments
Lockable door
Ventilation
The substation ventilation
is designed to optimize air
circulation over and around
the transformers and through
the panel compartment so
that the substation operates
at lower temperatures.
Substations come equipped
with temperature controlled
cooling fans for exhausting
hot air from the cabinet and
solar shield.
6
Substations
6
Temperature-controlled
fans for cooling
Stainless steel housing
with polyester
powder coating
6
6
6
6
6
6
Limited
lifetime
warranty
on the
housing
6
6
Stainless steel hardware
with locking doors
6
6
In addition, substations are
available with a doublewalled cabinet and solar
shield, which allow for
cooling of both the exterior
surface of the cabinet and
the internal components.
6
6
6
6
6
6
Custom made to your specifications:
Single-phase or three-phase copper
wound transformers
50 to 330 kVA
Up to 1200A main circuit breaker with
20 single-phase or 12 three-phase
branch circuit breakers
6
6
Sun Heat
6
6
6
Air
Transformers
6
Double-Walled
Stainless
6
6
6
6
Cool Air
6
Double-Walled Construction
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
371
6.5
6
●
●
6
6
●
6
6
●
6
●
6
●
6
●
6
●
6
●
6
6
6
6
6
6
Marina Power and Lighting Equipment
Available Options
6
6
Power Pedestals
●
●
Powder-coated cabinets
made of stainless steel
or fiberglass
Limited lifetime warranty
on housing. Transformer
and secondary distribution
panel in a single enclosure
have a one-year limited
warranty
Stainless steel housing
and hardware with
locking doors
Single-phase and threephase models
Overload capacity meets
ANSI L57.96–01.250
Optional double-walled
construction
Temperature controlled
fans for cooling
Custom-made copper
wound single-phase or
three-phase transformers
from 50–330 kVA
Up to 1200A main circuit
breaker with 15 singlephase branch circuit
breakers or 10 three-phase
branch circuit breakers
Substations can be
equipped with photocells
to turn on and off lights
A 20A GFI can be installed
in the cabinet, as well as
a ground fault monitoring
system
Standards and Certifications
●
cULus listed
Dimensions
Approximate Dimensions in
Inches (mm)
Substations
Standard Substation
Height
53.00 (1346.2)
Width
51.00 (1295.4)
Depth
33.00 (838.2)
Side-by-Side Substation
Height
53.00 (1346.2)
Width
66.00 (1676.4)
Depth
30.00 (762.0)
Double Panel Substation
Height
53.00 (1346.2)
Width
63.00 (1600.2)
Depth
33.00 (838.2)
6
6
6
6
6
6
6
6
6
6
6
6
372
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Power Pedestals
Marina Power and Lighting Equipment
6.5
Contents
Panels
Description
Panel (Stainless Steel Shown)
Page
Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint . . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels
Distribution Equipment—Transformers . . . . . . . . . . . . . . . .
335
338
342
346
349
353
357
363
364
365
366
367
370
374
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Distribution Equipment—Panels
Product Description
Features
Two of the many products
we can offer our customers
are Eaton’s PRL-3A and
PRL-4 panels as standalone
units or in one of our
substations. All of our busses
are made of copper and are
load rated; breakers are
bolt-on type. Distribution
panels can be 120/240V
single-phase, 120/208V threephase, 277/480V three-phase
or 220Y/127V three-phase
based on your system
requirements. Distribution
panels can also have a main
breaker or a main lug. Branch
circuit breakers are provided
based on customer
requirements.
●
●
●
All internal wiring is
fine stranded 1000V
insulated copper
Copper bus bars
All exterior hardware
is stainless steel
Available Options
●
●
●
●
●
●
NEMA 3R or 4X
Powder-coated
stainless steel
Main breaker up to 1200A
Branch breaker 20–1200A
Main lug only
We also offer 480V
models—single-phase
and three-phase
Standards and Certifications
●
●
UL listed
cULus listed
6
6
6
6
6
6
Single-Phase
Up to 1200A main
circuit breakers
●
Up to 42 branch
circuit breakers
●
6
6
6
Three-Phase
Up to 1200A main
circuit breakers
●
Up to 42 branch
circuit breakers
●
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
373
6.5
6
Power Pedestals
Marina Power and Lighting Equipment
Contents
Transformers
Description
6
6
6
6
6
6
6
6
Three-Phase Transformer
Page
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters. . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint. . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers
335
338
342
346
349
353
357
363
364
365
366
367
370
373
6
6
6
6
6
Distribution Equipment—Transformers
6
Product Description
Features
Because of the high humidity
and corrosive conditions of
coastal environments, our
transformers are wound with
Class H heavily insulated
copper bar and are double
dipped in tough insulating
varnish that protects the
copper, as well as reduces
the hum that is typical in
a transformer that is not
double dipped. We provide
a second overcoat of high
temperature epoxy to protect
against the severe saltwater
environment. We can provide
this transformer in singlephase, from 50–500 kVA,
and three-phase, from
45–300 kVA.
●
6
6
6
6
6
6
6
6
6
●
●
●
●
Copper wound transformer
coils double dipped in high
temperature baking varnish
All internal wiring is
fine stranded 2000V
insulated copper
Copper bus bars
Marine transformers
with epoxy overcoat
All copper-to-copper
connections
Available Options
●
●
●
Single-phase: 50–500 kVA
Three-phase: 45–300 kVA
Epoxy overcoat for nonmarine applications
Standards and Certifications
●
cULus listed
Primary Voltages
480 wye three-phase
●
480V three-phase delta
three-wire + ground
●
480V single-phase
two-wire + ground
●
Secondary Voltages
127/220V three-phase
wye four-wire
●
120/208V three-phase
wye four-wire
●
120/240V single-phase
three-wire
●
Marina Power Distribution
Transformer kVA Availabilities
●
Single-phase: 50, 75, 100,
150, 167.5, 200, 250, 330,
500 kVA
●
Three-phase: 45, 75,
112.5, 150, 225, 300 kVA
6
6
6
6
6
6
374
Volume 1—Residential and Light Commercial CA08100002E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Index
A
Abase, 25
ABC, 23-24, 27
able, 1, 29, 36
AC, 5, 9, 32
accept, 8
Access, 14, 22
access, 4, 8-9, 25-27
Accessories, 4, 7-8, 11-12, 15, 19, 23, 25
accessories, 27
AccessoriesSee, 14, 18, 22
accuracy, 31
activate, 29, 32
activated, 23, 29
adapter, 26
addition, 37
additional, 3
Adjustable, 32
Admiral, 1-4, 8, 12-15, 19, 23, 29-33, 36, 39-40
adpt, 26
against, 40
Aid, 9
Air, 37
air, 36-37
Alarm, 2, 23-24
alarm, 23-24, 32
Alaska, 4, 30
All, 31, 36-37, 39-40
all, 1, 4, 8, 12, 31, 33
allow, 31, 37
allows, 36
also, 1, 5, 12-13, 19-20, 29, 39
alternative, 19
aluminum, 25-26, 36
Amber, 6, 10, 13, 17, 21, 24-25, 27, 30
amber, 4-5, 8-9, 15-16, 19-20, 23, 25-26
AmberC, 6
AmberE, 24
AmberF, 6, 10
American, 31
amount, 29, 32
amperage, 12
An, 36
an, 19, 23, 31-32
anadian, 17
and, 1-40
ANote, 4
ANSI, 31, 38
any, 12, 23, 29, 36
Application, 36
applications, 30-31, 36
applicationsfine, 40
approved, 31
Approximate, 7, 11, 14, 18, 22, 29-30, 35, 38
are, 5, 9, 12, 16, 19-20, 31-32, 36-37, 39-40
areas, 19, 30
around, 4, 19, 32, 37
Article, 4
as, 1, 8, 12, 19, 23, 31, 38-40
asked, 29
Assemblies, 26
AssembliesLighthouse, 26
Assembly, 25
assembly, 2, 19, 23, 25-27
assist, 36
Index
at, 1-40
attractive, 19
audible, 32
automatically, 23
automation, 1
Availabilities, 40
Availability, 3
Available, 4-5, 8-9, 12, 15-16, 19-20, 23-24, 31, 33, 36,
38-40
available, 1, 3, 5, 8-9, 12-13, 15-16, 20, 24, 30-31, 36-37
availablefault, 32
B
Back, 14
backflow, 26
Backlit, 4, 8-9, 16
baked, 23
baking, 40
ball, 5-6, 10, 12-13, 16-17, 20-21, 26
ballast, 25
Bar, 5, 9, 20, 22
bar, 2, 4, 6, 8, 10, 13, 15, 17, 19, 21, 25-27, 40
barN, 6, 10
barrel, 27
bars, 25, 33, 39-40
barT, 6, 10
Base, 5, 14, 30, 35
base, 4, 23, 25, 30
based, 39
be, 1, 4-5, 9, 12, 16, 20, 23, 29-32, 36, 38-39
Benefits, 4, 8, 15, 19, 23, 36-37
between, 36
beyond, 1, 30
bib, 20, 26
bibs, 5-6, 9-10, 12-13, 16-17, 21, 26
billing, 31
Black, 30
Blank, 27
blank, 25
block, 27
blocks, 29
Blue, 30
boardwalks, 19
boat, 29
boater, 29
Boaters, 29
boaters, 29
bollard, 30
bolt, 39
both, 4, 6, 10, 13, 31, 33, 37
box, 15-16
bracket, 9, 27
brackets, 4-5, 25-27
bracketsquality, 8
Branch, 39
branch, 32, 36-39
brass, 16, 20, 26
Breaker, 17, 21, 34
breaker, 25-26, 32-33, 37-39
Breakers, 17, 21, 25
breakers, 2, 4-5, 9, 16, 19-20, 25-27, 33, 36-39
Broken, 7
bug, 4-5, 8-9, 15-16, 19-20, 23
Built, 5
Bulb, 30
bulb, 25, 30
Bus, 2, 5-6, 9-10, 13, 17, 20-22, 27
bus, 4, 6, 8, 10, 13, 15, 17, 19, 21, 25-27, 33, 39-40
Buss, 34
busses, 39
But, 8
but, 19, 29
by, 29, 31-32, 38
C
CA, 1-40
cabinet, 33, 36-38
cabinets, 36, 38
Cable, 2, 5-6, 9-10, 13, 17, 21, 26
cable, 4-5, 8-9, 12, 16, 20, 25-27
California, 31
call, 1-40
camera, 2
Camp, 17, 26-27
Can, 30
can, 1, 4, 12, 23, 30-32, 36, 38-40
Canadian, 6, 10, 13, 17, 21
cap, 5
Capabilities, 31
capabilities, 12
capable, 31
capacity, 38
Card, 2
card, 29
Index
CAT, 26, 33
Cat, 12
Catalog, 4, 6, 8, 10, 13, 15, 17, 19, 21, 23-27, 30
CATV, 14, 33
center, 15
central, 31
centrally, 29
Certifications, 29, 36, 38-39
CertificationsBecause, 40
CertificationsOur, 32
channel, 23
chosen, 29
Circuit, 19-20, 25
circuit, 32, 36-39
circuits, 32
circulation, 37
ckable, 9
cket, 13
Class, 40
Clear, 4, 6, 8, 10, 13, 17, 19, 21, 24-25, 27, 30
clear, 4, 8, 12, 15, 19, 23
climates, 33
closure, 25
coastal, 36
coated, 9, 12, 23, 32, 36, 38-39
coating, 4-5, 19-20, 33, 37
Coax, 26
coil, 26, 31
coils, 40
Color, 6, 10, 13, 17, 21, 24, 30
color, 4, 19
colors, 30
com, 1-40
combination, 16
Combinations, 36
combinations, 12
combined, 1
combo, 16
come, 29, 36-37
comes, 19
Commercial, 1-40
common, 31
compact, 15
company, 1, 33
compartment, 33, 37
compartments, 37
compatible, 2
complementary, 1
Complete, 26-27
complete, 1, 23, 25-26, 36
components, 37
comprehensive, 1
condition, 31-32
conditions, 4, 40
Configuration, 3
configuration, 5
configurations, 5, 8, 20, 26
configured, 30, 36
connected, 31
connection, 9
Connections, 5, 9
connections, 5, 12, 16, 20, 31, 33, 40
connectionsAdmiral, 12
connectionsrge, 9
connector, 31
constantly, 1
constructed, 36
Construction, 37
construction, 38
consumption, 31
Contact, 13
contact, 26-27
contained, 15, 33
Contents, 1, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
continued, 25-27
continuedCatalog, 26
control, 1, 23, 29
controlled, 4-5, 8-9, 12, 15-16, 19, 23, 33, 36-38
Cool, 37
cooler, 33
cooling, 33, 36-38
Copper, 4-5, 8-9, 15, 19-20, 25-27, 39-40
copper, 6, 10, 13, 17, 21, 33, 36-40
copperdipped, 40
Corporation, 29
corrode, 19
corrosive, 40
cost, 19
Counter, 26
counter, 31
counters, 31
cover, 25-26
Created, 23
credit, 29
CT, 32, 34
CTs, 26
cULus, 38-40
Current, 32
current, 32
currents, 32
Custom, 4-5, 19-20, 25, 30, 37-38
custom, 27
customer, 39
customers, 1, 31, 36, 39
Index
D
damage, 32
Dark, 30
day, 29, 32
December, 1-40
deck, 19
degree, 19
degrees, 12
delivers, 33
Delivery, 1-40
delta, 33, 40
Depth, 2, 29, 38
Description, 1, 4, 8, 12, 15, 19, 23, 25-27, 29-33, 36,
39-40
Design, 25
design, 36
Designed, 15-16
designed, 31-32, 36-37
designs, 1
desired, 30
details, 13
detect, 32
detected, 32
detects, 32
determine, 26
developed, 29
developers, 1
development, 1, 15
device, 32
Di, 17
Diagram, 33-34
diameterare, 32
Digital, 1, 4-6, 8-10, 12-13, 15-16, 19-21, 23, 26, 29-33,
36, 39-40
digital, 1, 31
Dimensions, 4, 7-8, 11-12, 14-15, 18-19, 22-23, 28-30,
33, 35-36, 38
DimensionsApproximate, 28
DimensionsThe, 30
dipped, 40
direct, 31
disconnect, 26, 32
displayed, 32
displaying, 31
Distribution, 1, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
distribution, 1, 38
dock, 15-16
docks, 19, 30
Door, 9, 27
door, 5, 16, 23, 25-27, 37
doors, 2, 4-5, 8-9, 37-38
Double, 36-38
double, 27, 33, 36-38, 40
down, 29
driven, 1
drives, 31
Dual, 6, 10, 12-13, 21, 24, 26
dual, 5, 9, 12, 16, 20, 26, 33
duplex, 6, 10, 13, 17, 21, 25
durability, 4
durable, 15-16
E
each, 5-6, 8-10, 13, 31
easy, 4, 8-9
Eaton, 1, 27, 29, 31, 33, 36, 39
eaton, 1-40
ed, 13
efficient, 23, 33
either, 32
Electric, 2
electric, 5, 33
Electrical, 1, 14
electrical, 1, 15, 32, 36
electricity, 9, 12
electro, 31
Electronic, 1, 4, 8, 12, 15-16, 19, 23, 26, 29-33, 36,
39-40
electronic, 1, 4-6, 8-10, 13, 16-17, 19-21, 31, 33
elegant, 19
Element, 31
element, 5, 9, 16, 20, 26
eliminate, 29
eliminates, 31
emergency, 23
Empty, 5
enables, 31
enamel, 23
enclosure, 29, 38
energy, 23
Engineered, 2, 4
engineered, 30
enhanced, 1
ensure, 33
enter, 29
entire, 1
Index
environment, 33, 36, 40
environments, 30, 40
Epoxy, 40
epoxy, 33, 40
eptacles, 10
Equipment, 1-40
equipment, 1
equipped, 23, 37-38
every, 31
exceeds, 31
exceptional, 4
exhausting, 37
extends, 5, 9
extension, 5
exterior, 37, 39
External, 2
external, 25-26, 31
Extinguisher, 24
extinguisher, 2, 23-24, 27, 33
extinguisherX, 24
Extra, 6, 10, 13
F
FA, 25-27
Faceplate, 9, 16, 20
faceplate, 4, 8, 25-27
faceplates, 27
facility, 27
factor, 31
factory, 13, 26
fans, 33, 36-38
FAthree, 25
Fault, 1, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
fault, 32, 38
faulted, 32
faulty, 32
FCF, 26
feature, 31
Features, 4, 8, 12, 15, 19, 23, 29-33, 36-37, 39-40
features, 4, 8, 15, 23
feed, 2
feet, 26, 30
female, 26
fiberglass, 32, 38
fine, 39
finish, 4-5, 15-16, 19-20, 23
Fire, 23-24, 33
fire, 23-24, 27
Firehouse, 1-2, 4, 8, 12, 15, 19, 23-24, 27-33, 36, 39-40
Five, 15, 31
five, 25
flagship, 12
flow, 36
fluo, 9
Fluorescent, 25
fluorescent, 4-5, 8, 12, 15-16, 19-20, 23, 25, 30, 33
Footprint, 14
For, 1-40
for, 1, 4-5, 8-9, 12-13, 15-16, 19-20, 23, 25-26, 29-31,
33, 36-38, 40
forElectronic, 34
found, 4, 19
Four, 12, 31
four, 23, 25-26, 33, 40
free, 6, 8-10, 29
friendly, 31
From, 33
from, 1, 4-5, 8-9, 29-32, 34, 36-38, 40
fromA, 34
Front, 7, 14, 22, 35
frost, 6, 10
full, 31
Functions, 4, 8, 15, 19, 23, 36-37
Fuse, 17, 21, 26-27
fuse, 25-27
fused, 25
G
Galvaneal, 36
general, 23
get, 31
GFCI, 25-26
GFI, 2-3, 5-6, 8-10, 12-13, 16-17, 20-21, 27, 33, 38
GFIs, 17, 21
GHC, 25
gital, 17
glass, 8
golf, 30
green, 30-31
Ground, 1, 4, 8, 12, 15, 19, 23, 29-34, 36, 39-40
ground, 32, 38, 40
Guard, 32
Guide, 1-2
GuideThe, 36
Index
H
I
Handles, 9
handles, 5, 12, 20
hangers, 2
Harbor, 1-4, 8, 12, 15-19, 23, 26-27, 29-33, 36, 39-40
Hard, 17, 21, 33-34
hard, 31
hardware, 2, 37-39
Hardwire, 2
harsh, 30
has, 1, 4, 29, 33
hasp, 27, 31
Hatteras, 1-4, 8, 12, 15, 19-23, 25-26, 29-33, 36, 39-40
have, 15, 29-30, 38-39
Heat, 37
heavily, 40
Heavy, 4, 12, 19, 33
Height, 2, 29-30, 38
heightcourses, 30
help, 33
Helping, 33
helps, 32
here, 8
High, 1, 5, 9, 23
high, 1, 8, 12-13, 16, 20, 26, 33, 40
highest, 1
highly, 33
hinge, 5, 25
Hingeless, 5
hingeless, 4
holder, 25-27
Hooking, 9
Hose, 2, 4-5, 8-9, 25
hose, 6, 9-10, 12-13, 16-17, 20-21, 26
Host, 15
hot, 37
Hour, 31
hour, 29
hours, 32
house, 1
Housing, 32
housing, 2, 4-5, 8-9, 12, 15-16, 19-20, 23, 25-27, 30, 33,
36-38
hum, 40
humidity, 40
Hz, 25
identified, 32
IEC, 33
If, 29, 32
Immediate, 1-40
improper, 31
In, 37
in, 1, 4-5, 7-9, 11-12, 14-16, 18-19, 22, 25, 28-33, 35-40
Inch, 24
inch, 6, 9-10, 12-13, 16-17, 20-21, 24, 26-27, 30, 32-33
Inches, 7, 11, 14, 18, 22, 28-30, 35, 38
inches, 5, 19
Include, 24
include, 27
indicate, 31
indicates, 31
indicator, 32
individual, 31
individually, 6, 17, 21
industrial, 1
information, 1, 32
inhibitor, 15-16
injury, 32
inland, 36
innovations, 33
innovative, 15
insert, 26
Inside, 22
installation, 4, 8-9
installed, 38
Institute, 31
insulated, 33, 39-40
insulating, 40
INT, 14
internal, 5, 9, 37, 39-40
Internet, 2, 5-6, 9-10, 12-13, 16-17, 20-21, 26, 33
internet, 26
into, 36
introduction, 36
is, 1, 4, 8, 12, 15, 19, 23, 29-33, 36-37, 39-40
isolation, 25, 33
It, 19
it, 29
its, 4, 33
Index
J
Jack, 6, 10, 13, 17, 21
jack, 26
jacks, 13, 26
jaw, 31
JT, 25
K
kcmil, 2, 6, 10, 13, 21
kcmilMaximum, 2
keep, 33
Kilowatt, 31
kilowatt, 4, 8, 19, 31
Kilowatthour, 1, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
kilowatthour, 31
kiosk, 29
KMParts, 1-40
Known, 1
known, 33
kVA, 33, 36-38, 40
kVAcoastal, 40
kVAto, 36
kVAwarranty, 36
L
La, 9
land, 30
landscape, 19
landscaped, 30
Large, 8
large, 26
lasting, 4-5, 8-9, 15-16, 19-20, 33
latest, 31
layout, 36
lb, 23-24, 27
lbs, 2, 33
le, 9
leader, 1
Learn, 1
LED, 2, 5-6, 9-10, 12-13, 16-17, 20-21, 24, 30-31
LEDs, 31
Left, 35
Lens, 6, 10, 13, 17, 21, 24, 30
lens, 4-5, 8, 12, 15-16, 19-20, 23, 25, 27
less, 21
level, 32
LHSS, 6, 10
Life, 2, 24, 27
life, 23-24, 27
lifetime, 2, 8-9, 19, 30, 33, 36-38
Light, 1-40
light, 2, 4-6, 8-10, 12-13, 15-17, 19-21, 23-25, 27, 33
Lighted, 29
Lighthouse, 1-12, 15, 19, 23, 25-26, 29-33, 36, 39-40
Lighting, 1-40
lighting, 2, 5-6, 9-10, 12-13, 17, 20-21, 24, 27, 30, 33
lightingSingle, 16
lightning, 5, 9
lights, 33, 38
lightwattage, 2
like, 8, 29
Limited, 2, 30, 33, 37-38
limited, 8-9, 19, 36, 38
line, 5, 9, 12, 25, 31
listed, 32, 38-40
listing, 29
Lo, 9
load, 31, 39
loadcenters, 1
located, 29
location, 31
lock, 2
Lockable, 2, 4-5, 16, 31, 37
lockable, 8
locking, 31, 33, 37
Long, 8-9
long, 4-5, 19-20, 33
Lookout, 2
looks, 1
loop, 2
low, 19, 32-33
lower, 37
lug, 6, 10, 13, 17, 21, 39
lugnut, 26
Index
M
MA, 6, 10, 13, 17, 21, 24, 30
mA, 32
Made, 33
made, 8, 37-39
Main, 2, 27, 34, 39
main, 5, 25-26, 32, 37-39
MainBreakerDual, 34
maintenance, 4, 8-9, 32
manifold, 26
manufactured, 8
manufactures, 31
many, 31, 39
MARINA, 27
Marina, 1-40
marina, 1, 23, 29-31, 33, 36
marinapower, 1
marinas, 4, 19
Marine, 26, 40
marine, 1, 30, 40
Mariner, 1-2, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
market, 36
Mate, 1-4, 8, 12, 15-19, 23, 26-27, 29-33, 36, 39-40
max, 5, 9, 12, 16, 20
Maximum, 2
maximum, 15, 19, 33
may, 32
means, 32
Mechanical, 17, 21
mechanical, 6, 10, 13, 17, 21, 31
Medical, 23
meets, 38
Mega, 1, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
mega, 33
Meter, 5, 8, 31, 34
meter, 1-2, 5-6, 8, 10, 13, 16, 20, 31, 33
metered, 6, 10, 17, 21
Metering, 6, 10, 13, 17, 21
metering, 5, 9, 12, 16, 20, 33
Meterred, 31
Meters, 1, 4, 8, 12, 15, 18-19, 23, 26, 29-33, 36, 39-40
meters, 2, 4-6, 8-10, 13, 16-17, 19, 21, 31, 33
mini, 15
mm, 7, 11, 14, 18, 22, 28-30, 35, 38
models, 15, 38-39
Monitor, 1, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
monitor, 32
monitored, 32
monitoring, 29, 32, 38
more, 1-2, 29
most, 4, 15, 33
mount, 15-16, 31
mounted, 23, 30
Mounting, 16, 26-27, 30
mounting, 26
mounts, 33
MPL, 25-27
MPLFH, 27
much, 1
N
National, 31
nch, 5
nearly, 12
NEC, 4
need, 29
needs, 1, 23
NEMA, 33, 36, 39
Neutral, 34
never, 19
New, 4-5, 9
new, 26-27, 29
newest, 29
Newport, 1-4, 8, 12, 15-16, 18-19, 23, 26-27, 29-33, 36,
39-40
NFPA, 4
Night, 9
night, 4, 8, 33
No, 2-3, 6, 10, 13, 17, 21, 24, 29
no, 3, 26
noise, 33
non, 32, 40
None, 2-3, 6, 10, 13, 17, 21
Not, 1
not, 5, 9, 12, 16-17, 19-21, 29, 40
Note, 3-5, 8-9, 12, 16, 19-20, 27
Notes, 6, 10, 13, 17, 21, 26
NP, 17
ns, 9
Number, 4, 6, 8, 10, 12-13, 15, 17, 19, 21, 23-27, 30
number, 29
NumberLighthouse, 26
Numbers, 25-27
nuts, 25-27
Index
O
P
occurs, 32
of, 4-6, 8-10, 12-13, 15-17, 19-21, 26, 29, 31-33, 36-40
off, 38
Offer, 1
offer, 1, 33, 39
offers, 8
old, 26
on, 1, 5, 9, 15-16, 30-33, 37-39
Once, 29
One, 2-4, 6, 10, 13-14, 31
one, 5-6, 9-10, 12-13, 16, 20, 31, 38-39
Online, 1
online, 1
ONLY, 17
only, 1, 17, 19, 25, 29, 31, 33, 39
ontrolled, 20
open, 23
operates, 32, 37
operation, 33
optimal, 33
optimize, 37
Option, 6, 10, 13, 16-17, 21
option, 2, 13, 30
Optional, 2, 5, 16, 23, 38
optional, 16, 23, 36
Options, 4-6, 8-10, 13, 15-17, 19-21, 23-24, 31, 33, 36,
38-40
options, 8
OptionsTruly, 12
or, 1-40
order, 29
other, 1, 27
Our, 31-32, 36
our, 4, 12, 31, 36, 39-40
out, 33
outlets, 1, 33
output, 31
oven, 23
over, 31, 37
overall, 32
overcoat, 40
overcoated, 33
Overload, 38
Overview, 1
packed, 15
Page, 1, 4, 7-8, 11-12, 14-15, 18-19, 22-23, 29-33, 36,
39-40
paint, 4, 19
painted, 30
Panel, 36, 38-39
panel, 8-9, 25, 27, 37-38
Panels, 1, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
panels, 36, 39
Panelyour, 36
Park, 21, 25-26
park, 31, 36
part, 4-5, 19-20
Parts, 25-27
parts, 5, 9
PC, 31
Pedestal, 2, 26
pedestal, 4-5, 9, 12, 16, 20, 23, 25, 29, 31, 36
Pedestals, 1-40
pedestals, 1, 4, 19, 29
pending, 29
per, 5, 9, 12, 16, 20, 31
performance, 8
personnel, 32
Ph, 5
Phase, 34, 36, 39-40
phase, 6, 8, 10, 12-13, 17, 21, 25-27, 31, 33, 36-40
Phasesubstation, 36
Phone, 6, 9-10, 13, 17, 20-21, 26
phone, 5, 9, 12, 16, 20, 26-27, 33
photo, 16
Photocell, 2, 4, 8, 12, 15-17, 19, 21, 23, 25
photocell, 33
photocells, 38
piece, 27
piling, 15-16
pin, 2, 25-26, 31
placed, 32
plate, 25-26
plates, 26
Please, 26
please, 27
plug, 4, 8
po, 37
Point, 2
polarity, 31
Pole, 30, 34
pole, 17, 21, 25, 30
Index
Police, 23
Polycarbonate, 23
polycarbonate, 23
polyester, 12, 23, 33, 37
polyurethane, 4-5, 19-20
pools, 19
popular, 4, 19
possesses, 12
Powder, 9, 38-39
powder, 9, 12, 23, 32-33, 36
Power, 1-40
power, 1, 4-5, 9, 12, 15-16, 20, 29, 31-33, 36
powered, 8
Powerhouse, 25-26
Powerpoint, 1, 4, 8, 12, 15, 19, 23, 29-36, 39-40
practicality, 4
pre, 27
prevent, 29
preventer, 26
Primary, 33-34, 40
primary, 36
printable, 29
private, 19
PRL, 39
problems, 31
Product, 1-2, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
product, 1, 29
Products, 25
products, 1, 8, 36, 39
Programmable, 29
property, 32
protect, 4-5, 9, 40
protected, 17, 21
Protection, 17, 21
protection, 33, 36
protects, 16, 40
prototype, 15
provide, 1, 40
provided, 12, 39
provider, 36
provides, 12, 32, 36
providing, 4, 31, 36
pulse, 31
pulsed, 31
pulses, 31
purpose, 4
PVC, 2
Q
QCF, 25
QCGF, 25
Quality, 1
quality, 1, 8, 33, 36
Quantity, 6, 10
quantity, 6, 10, 13, 17, 21
Quick, 2
quick, 26
quiet, 33
R
range, 4, 31
rate, 31
rated, 33, 39
rates, 29
rather, 31
rating, 2, 15, 19
Ratings, 5, 9, 20
ratings, 4, 8
read, 31
reading, 1-2, 4, 8, 19, 31
readings, 31
receipts, 29
receiver, 31
Receptacle, 3, 5-6, 8, 10, 13, 17, 20-21
receptacle, 4-5, 8-9, 12, 16, 20, 25-26, 33
receptaclePhone, 16
Receptacles, 2-3, 6, 10, 13, 17, 21, 25
receptacles, 3-6, 9-10, 12, 16, 20, 33
Receptacleup, 20
Recindividually, 10
recognized, 4
recommended, 36
recreational, 36
Red, 27
Redesign, 18
reduce, 32
reduces, 40
reduction, 4-5, 8-9, 15-16, 19-20, 23
Remote, 2, 23
remote, 1, 4-5, 8-9, 12, 19, 33
removable, 8-9
Removed, 22
Index
removed, 23
Replacement, 25-27
replacement, 26
represents, 6, 10, 13, 17, 21
required, 31
requirement, 4
requirements, 39
requires, 31
rescent, 9
rescue, 23
Residential, 1-40
Resin, 5, 25
resin, 2, 4, 12, 15-16, 19-20, 25-26, 30
resistant, 4-5, 19-20
result, 32
reverse, 31
Right, 35
Ring, 24, 31
ring, 2, 23-24, 27
Ringless, 31
ringPhotocell, 24
risk, 32
RJ, 5, 9, 13, 26
rotect, 5
run, 33
Russellstoll, 25
rust, 19
RV, 25-27, 31, 36
S
safety, 1
saltwater, 40
same, 8, 19
second, 40
Secondary, 33, 40
secondary, 38
Security, 2
See, 7, 11
select, 23
Selection, 1-2, 4, 6, 8, 10, 12-13, 15, 17, 19, 21, 23-24,
30-31, 36
self, 33
send, 32
serve, 12, 33
service, 1, 4, 36
ServiceA, 34
services, 1, 15, 23
set, 25-26
Seven, 31
severe, 4, 40
Shield, 35
shield, 33, 37
shields, 33
shore, 5, 9, 12, 16, 20, 32
Shown, 16, 39
shown, 16
shut, 29
Side, 3, 6-7, 10, 13-14, 20, 22, 30, 35, 38
side, 5-6, 8-10, 13, 33
sided, 36
Sides, 6, 10, 13, 17, 21
sides, 6, 10, 13
signal, 32
silcock, 20, 26
Simple, 31
Single, 5-6, 9-10, 12-13, 16-17, 20-21, 25-26, 34, 36-40
single, 2, 8, 12, 16, 25, 31, 33, 36-40
singlephase, 33, 38
siren, 23, 27
site, 31
situation, 29
size, 2, 12, 21
sleeve, 2, 25
slip, 29
slips, 19, 29
small, 26
smaller, 19
Smart, 1, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
so, 13, 37
Socket, 5, 31
socket, 5-6, 8, 10, 13, 25
sockets, 31
Solar, 35
solar, 37
solution, 1, 23
solutions, 1
sources, 31
Special, 6, 10, 13, 17, 21, 24, 30
SpecialB, 24
SpecialH, 24
specifications, 37
speed, 5, 9, 12-13, 16, 20, 26, 33
spikes, 5, 9
split, 6, 10, 13, 17
spring, 25
SS, 1-4, 8-9, 11-15, 19, 23, 25-26, 28-33, 36, 39-40
SSCatalog, 12
staff, 32
Stainless, 2, 5, 16, 23, 25, 37-39
stainless, 5, 8-9, 12, 15-16, 20, 23, 25-27, 29, 32-33,
36-39
Index
Stand, 16-17, 30
stand, 2, 15-17, 27, 30
standalone, 39
Standard, 2, 31, 38
standard, 8, 36
Standards, 29, 31-32, 36, 38-40
Start, 1, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
state, 31
stealing, 29
Steel, 25, 39
steel, 2, 5, 8-9, 12, 15-16, 20, 23, 25-27, 29, 32-33, 36-39
storage, 23
stranded, 39-40
stray, 32
strobe, 2, 23-24, 27
StrobeN, 24
strong, 15
style, 8, 26
stylish, 4
Substation, 36, 38
substation, 37
Substationlocking, 38
Substations, 1, 4, 8, 12, 15, 19, 23, 29-33, 36-40
substations, 36-37, 39
Substationson, 38
such, 12, 31
Sun, 37
sun, 33
superior, 8
supplied, 30
supplier, 36
suppliers, 1
Supply, 34
supply, 1
Support, 1-40
suppressor, 5, 9
surface, 31, 37
surge, 5, 9
surges, 5, 9
surrounding, 1
swipe, 2, 29
switch, 27
switches, 1
System, 31
system, 32, 36, 38-39
systems, 32
T
tall, 19, 30
Tech, 1-40
technical, 32
technology, 31
Telephone, 2
Temperature, 37-38
temperature, 36-37, 40
temperatures, 37
tenth, 31
terminal, 27
than, 1, 31
that, 1, 4-5, 9, 12, 16, 30-33, 36-37, 40
The, 8, 19, 23, 29-33, 36-37
the, 1, 4-6, 8-10, 12-13, 15, 17, 19, 21, 23, 29-33, 36-40
their, 1, 29
then, 29
Thermostatically, 33
these, 12, 19
they, 29
This, 19, 23, 31
this, 4, 15, 23, 33, 40
Thousands, 19
Three, 6, 10, 13, 17, 21, 25-26, 31, 34, 36, 39-40
three, 5, 8-9, 12, 25-27, 31, 33, 36-40
threephase, 39
through, 31, 37
time, 29
To, 34
to, 1-2, 4-5, 8-9, 12, 15-16, 19-20, 26-27, 29-33, 36-40
too, 32
Top, 2, 7, 22, 25, 35
top, 23, 25, 27
total, 12
Tough, 15-16
tough, 40
tranquil, 33
Transformer, 34, 36, 38, 40
transformer, 33, 37, 40
Transformers, 1, 4, 8, 12, 15, 19, 23, 29-33, 36-37, 39-40
transformers, 26, 32, 36-38, 40
transformersdetect, 32
Transient, 5, 9
transient, 29
transmission, 31
transmitter, 23, 31
trip, 32
tropical, 33
tropics, 4, 30
Index
turn, 5-6, 10, 12-13, 16-17, 20-21, 26, 38
TV, 2, 5-6, 9-10, 12-13, 16-17, 20-21, 26
TVSS, 2, 5, 9
twist, 2
twistlock, 25
Two, 2-3, 6, 10, 13-14, 25, 31, 33, 39
two, 4-6, 9-10, 12-13, 16-17, 19-21, 25, 33, 40
Typ, 34
Type, 6, 10, 13, 17, 21, 23-24, 27, 30
type, 31, 39
typical, 40
Ventilation, 37
ventilation, 37
very, 33
via, 23
View, 7, 22
visibility, 23
visit, 1
visiting, 31
Visual, 32
voltage, 5, 9, 12
Voltages, 40
voltages, 12, 33
Volume, 1-40
VU, 6
U
UL, 29, 32, 39
Unit, 35
unit, 12, 15, 19, 23, 33
unitized, 12
units, 4, 39
Unmeter, 13
Unmetered, 6, 10, 13, 17, 21
Up, 2, 9, 33, 37-39
up, 2, 12, 29, 31-32, 36, 39
us, 1
use, 4, 29, 36
used, 5, 9, 12, 16, 20, 30-31
user, 31
uses, 19
Using, 31
using, 1
Utility, 34
utmost, 36
UV, 4-5, 15-16, 19-20
V
vailable, 3
valve, 16, 20, 26
valves, 5-6, 10, 12-13, 17, 21, 26
variety, 15
various, 30
varnish, 40
vehicle, 36
Ventilated, 33
W
wall, 16, 36
Walled, 37
walled, 37-38
wants, 29
warning, 23
warranty, 5, 8-9, 19, 30, 33, 37-38
WarrantyHousing, 2
washer, 26
washers, 25-27
Water, 2, 6, 10, 13-14, 17, 21, 26
water, 5-6, 9-10, 12-13, 26, 33
watt, 4-5, 8-9, 12, 15-16, 19-20, 23, 25, 30, 33
Wattage, 30
Watts, 26
ways, 1
wder, 37
We, 1, 36, 39-40
we, 1, 39
weather, 4
Weatherproof, 1
weatherproof, 4-5, 8-9, 16
well, 23, 38, 40
What, 1
When, 29
when, 12, 23
where, 32
which, 32, 37
while, 4
White, 30
wide, 4
Width, 2, 29, 38
Index
will, 1, 19, 29-30, 32
Wire, 21, 34
wire, 2, 25, 40
Wired, 17, 21
wired, 31
Wireless, 4-5, 8-9, 12, 19, 31, 33
wireless, 1, 31
Wiring, 33-34
wiring, 33, 39-40
With, 4, 18, 35
with, 1, 3-6, 8-10, 12-13, 15-17, 19-21, 23, 25-27, 30,
32-33, 36-38, 40
without, 25
withstand, 4, 30
world, 4
would, 29
wound, 33, 36-38, 40
www, 1-40
wye, 33, 40
Y
Yacht, 1, 4, 8, 12, 15, 19, 23, 29-33, 36, 39-40
yacht, 33
yachts, 33
Ye, 3
year, 2, 38
years, 2, 5, 9, 15
Yes, 2-3, 17, 21, 24
YesFire, 2
YesWater, 2
yet, 15, 19
yielded, 15
you, 29
your, 1, 29, 33, 36-37, 39

Similar documents

Power Outlet Panels - Carlton

Power Outlet Panels - Carlton Temporary Power Product and Application Description. . . . . . . . . . . . . . . . . . . . . . . . . . 2 Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 U...

More information