RSLogix Systems
Transcription
RSLogix Systems
General information / preparation Setting up the network configuration and parameters Quick Guide for EDS available at www.festo.com/sp/cpx EDS allows basic configuration in the host-system CPX-FB36 EtherNet/IP with Allen Bradley controllers Documentations with detailed descriptions are available at the Festo Support Portal. Go to www.festo.com/sp/cpx Search for: CPX-FB36 (manual): CPX-SYS (CPX-System System manual): EN – 8024075 EN – 526446 Additional information about EtherNet/IP can be found on: • www.odva.org Start--up up hardware settings 1 1 Operating mode: 2 Additional Diagnostic Bits: Using RSLogix 5000 for EtherNet/IP 1. Add the CPX CPX-FB36 as new module above the Ethernet/IP bridge - deactivated Default Remote I/O When FEC or CEC is integrated 2. Use the profile “Generic Ethernet Device” within RSLogix Status LEDs (see 4) From RSLogix Rev20 You can also use the EDS EDS-File for configuration. In this case “CPX “CPX-FB36” Can be selected instead Of “Generic Ethernet Module” 1. Dynamic addressing BOOTP/DHCP 2. Manual IP addressing M12 D-coded D Ethernet connection See manual: Chapter 1.2 3 See manual: Chapter 3.1 Using RSLogix 5000 for EtherNet/IP 4 3. Enter the following in the window “Module Properties” - Name for field bus node - Instances for inputs (101 101) and outputs (100) with according sizes - Instance for Configuration Assembly ((102)) with size: 0 - Data Format: SINT - Insert IP address Device status Using LED’s for the device status identification Modul status Network status TP1/TP2 Device status normal Device not ready Device has connection to PLC Network ok, no connection Address problem or bus off No Ethernet connection Network ok Data traffic CPX hardware status System failure Terminal with only outputs: Activate Diagnose Interface (+ 2 Byte I/O) or the Statusbits (+ 2 Bytes I) For the input/output sizes see the Tip “CPX “CPX-FB36 I/O mapping” Festo AG & Co KG Power system/load Terminal with only inputs: Activate Diagnose Interface (+ 2 ByteI/O) Modify status OK Information Diagnostic Hardware defect Power ok Outside tolerance Ok Saved parameters Forced active See manual: Chapter 3.2 Quick Guide for CPX-FB36 FB36 Version A1 CPX-FB36 I/O mapping Tip Input data order Tip Output data order The ‘Boot DHCP SERVER’ tool recognizes BOOTP devices and enables an easy configuration of a static IP address for the CPX. I/O Diagnostic Bits (Deactivated by default) 1 I/O Diagnostic Bits (Deactivated by default) Analogue modules, each channel 16 Bit 2 Analogue modules, each channel 16 Bit 3 Technologies modules (e.g. CPI Interface, CPX-FEC) 4 Digital and valve modules (I/O, MPA, Pneu. Interface) Technologies modules (e.g. CPI Interface, CPX-FEC) Using Boot DHCP SERVER to set the IP address 1. First start the Boot DHCP SERVER 2. Configure the network. 3. - In the window “Request History” you find all devices in the network - Via the MAC ID the Festo EtherNet/IP can be identified (MAC ID also on label) - Mark the node and press button “Add to relation list” Note: The internal CPX mapping cannot be changed by the configuration tools! In addition read appendix B of the CPX-FB36 manual Tip Changing parameters of the CPX via L5K option Note: If you want that the settings available after power off/on then you must in the “Relation List” press “Disable BOOTP/DHCP” Tip Changing parameters of the CPX via L5K option 1. Change the parameters in FMT as needed (all parameters can also be changed in RSLogix after the export/import procedure) 4. Open now your current project and copy the CPX configuration from your opened project inside the current one via drop & drag. 2. Select File->Export->RSLogix (.L5K) and save file to disk Short Summary: At least 1 input and 1 output byte is necessary 3. Importing the L5K file (File -> Open -> “...”.L5K The benefits are: • Correct data format and I/O size at Generic Ethernet Device • Integration of all CPX start up parameters at the Controller-Tags Tip Mapping in RSLogix 5000 Tip After the right I/O mapping (see Point 3) you’ll find the process data inside the RSLogix project at the Controller-Tags fields. Changing parameters of the CPX without L5K option • Use CPX-MMI or FMT (Festo Maintenance Tool) with Ethernet connection to change parameters. • In “ System parameter “ choose for the Start-UP parameter the option -> “Saved parameter” Example for Input 3 Byte and output 3 Byte: On click Controller-Tags -> Input data Output data data format: SINT Note: The configuration data “Festo:C” can be used for setting CPXParameters Festo AG & Co KG Be carefully if you change the node. You might lose saved parameters. A lighting M-LED indicates stored parameter changes See manual: Chapter 3.2 Quick Guide for CPX-FB36 Version A1
Similar documents
BR Belted Series Electrical Manual Rev 21 Date 11-12-12
carousel 20 pocket ATC with 24 pocket. 1-17-05 Rev 11 Update schematics, power connection alert, parts lists, axis and spindle parameter listings 1-31-05 Rev 11 Update schematics and parts list to ...
More informationgateway nx100
the German versions are being prepared and will be available soon • For more, go to my versiondog (http://my.versiondog.com) and visit versiondog info data management for automation Copyright by AU...
More information