Freeze Dryers
Transcription
Freeze Dryers
KRYONIK Freeze Dryer Pharmalab has formed an alliance with SERAIL to acquire state-of-the -art technology and manufacture Freeze Dryers in India. The combined expertise of Pharmalab and Serail is now available to the pharmaceutical and biotechnology industry in India and worldwide. PHARMALAB Pharmalab, founded in 1962, has grown from a modest engineering company manufacturing stainless steel process and packaging equipments, to a world class company with a reputation for state-of-the-art technology that is trusted globally. Responsible for hundreds of prestigious installations worldwide in the pharmaceutical, biotech, food and beverages, cosmetics and agro chemical industries, Pharmalab is a name synonmous with purity and stringent quality standards. The company is supported by over 650 highly trained engineering professionals working across 4 manufacturing facilities in India (a total of 100000 sqft) and has tie ups with global leaders for various state-of-the art technologies. Pharmalab has a complete understanding of the pharmaceutical and other industries and offers a comprehensive package of products to increase the efficiency of its customers. Meeting challenges of speed and cost Freeze Dryers from Pharmalab - Serail SERAIL SERAIL, based in France, and a division of Charlem Holding, has established itself as a globally renowned company engaged in the design and manufacturing of high technology Freeze Dryers (lyophilizers) along with automatic loading and unloading systems. With more than 40 years of experience in Pharmaceutical Freeze Dryers, SERAIL has knowledge and track record to support customers globally and continually exceeds customer expectations. Serail is the pioneer of several innovations: • UNIFLUID TM refrigeration system ‘ • *Isolated Automatic Shelf Loading/Unloading system, • *Validated CIP system with 180° mechanically driven rotating spraying system and various others . Pharmalab India Private Ltd., Kasturi, 3rd floor, Sanghvi Estate, Govandi Station Rd, Govandi (E), Mumbai 400 088, INDIA. Tel.: +91-22-66 22 9900 • Fax: +91-22-66 22 9800 • E-mail: [email protected] • Website: www.pharmalab.com Serail lyophilizers are customized to exact application, designed for precise quality control, operator convenience, efficient production cycles, easy maintenance, best validation, shorter cycle times and speedier deliveries and bottom line- best return on investment. FREEZE DRYING PROCESS SCADA system for process control Stoppering system Vacuum system Ice Condenser collects sublimed ice vapours from product until it is completely dry Vacuum chamber; CIP & SIP’ able Isolation valve Mechanical refrigeration/liquid N2 cooling system TABLE SP Series 0.8 1.3 2 3 5 5 7.5 11 14 19 22 33 Kg 30 30 30 70 70 120 120 120 240 240 500 500 Ice capacity (per day) Kg 15 15 15 35 35 60 60 60 120 120 250 250 Shelf area m2 0.77 1.28 1.87 3.06 4.90 4.60 7.66 11.49 14.04 18.90 22.50 33 Shelf width mm 340 340 340 680 680 1030 1030 1030 1350 1350 1500 1500 Shelf length mm 750 750 1100 750 1200 750 1860 1860 1300 2000 1500 2200 Inter shelf spacing mm 165 90 90 100 100 100 160 100 90 110 90 90 Number of shelves Nos. 3+1 5+1 5+1 6+1 6+1 6+1 4+1 6+1 8+1 7+1 10+1 10+1 Ice capacity (max) Ice vapor Dried Product Glass Vial Stoppered Chamber type Dry Frozen Product Drying Freezing Liquid TYPICAL PRODUCT PROCESSING +40 +20 Time -20 -40 -60 Freezing 100 Primary Drying Secondary Drying 0 ice Frozen interstitial material Sublimation Desorption Adsorbed “bound “water 0 % ice formed RMI Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Condenser type Std. Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Condenser type Option External External External External External External External External External External External External Overall width mm 1650 1650 1650 2300 2300 2300 2300 2300 2300 2300 2600 2600 Overall length mm 3165 3165 3415 5150 5600 5240 6000 6000 5300 5800 5300 5800 Overall height mm 2400 2400 2400 2900 2900 3000 3000 3000 3200 3200 3200 3200 Vial capacity (16 mm Ø) Nos. 2600 4300 6500 10600 17300 16100 27200 51000 49700 67300 80300 117000 Vial capacity (22 mm Ø) Nos. 1300 2200 3300 5600 8900 8600 14200 21400 26300 35200 42100 62100 Vial capacity (24 mm Ø) Nos. 1100 1900 2800 4600 7500 7000 11900 17900 22000 29800 35700 52000 AFTER SALES SERVICE ADVANTAGE SERAIL-PHARMALABFREEZE When you partner with Pharmalab your goals become ours too… and helping you reach them is our commitment. Our philosophy is to synergize design, material, function and service to ensure our Freeze Dryers are GMP compliant and exceeding expectations of quality and performance.. Chambers, shelves, door closing systems, stoppering system, condensers and all interconnections are manufactured and quality controlled in-house to minimize risk and protect against any possible outer contamination. MAINTENANCE: DRYER When building systems we strictly follow instructions and all qualification tests are carried out in the presence of the buyer prior to delivery. To ensure your system maintains its optimal value, regular maintenance is a necessity and our team is always there to work with you. For system reliability, computer-controlled systems are preprogrammed to monitor the performance of all major components. When parameters deviate from acceptable levels, the control system notifies the user of the need for maintenance. Our engineers are ready to assist you on and look directly inside the process when problems occur. Our software delivers immediate on-line, step by-step troubleshooting and documentation for repair of manufacturing equipment and process documents with trending and multileveled security. CYLINDRICAL CHAMBER: • Following PED/ASME design code • SS316 L construction • Highest level of assurance maintaining sanitary conditions • Uniform temperature distribution during SIP TRAINING: • Highest resistance to pressure: Design pressure 2.8 Bar(g) Pharmalab offers training programmes for operators and maintenance personnel tailored to the customer’s requirements. Based on the customer’s freeze dryer configuration these trainings cover design and function of the main components, for example refrigeration skid, vacuum pumps and control system as well as fundamentals of the freeze drying process. • No corners and natural drain ensures easy drainability • Light in weight for easy installation • Full door & sub-door design OUR AFTER SALES SERVICES INCLUDE: • Maintenance Contracts • Preventive Maintenance Services • Recipe Development/Cycle Development SHELVES: • OperatorTraining On & Off Site • SS316 L construction • Spare Parts and Retrofits • Surface finish - 0.6 µm or lower MODEL SPXXS • Bench top unit • Ideal for research in clinical biotech & pharmaceutical labs • Flatness: < ± 1 mm per meter • Specific baffle design for uniform temp. • Helium leak tested • ± 1° C temperature accuracy • Compact design • Flexible • Top loading system • Chamber: AISI 316L • Ice condenser coil located in the chamber: AISI 316L • 12 port manifold • Stoppering device • In-built heating system • Air cooled refrigeration system ICE CONDENSER (INTERNAL): • R404A Eco friendly refrigerant • Following PED/ASME design code • PLC operation…option • SS316 L construction • 3 channel recorder…option • Coil externally electro-polished • Mobile system……option • Faster sublimation process • Defrosting by pure steam or hot water • Uniform ice thickness • External condenser (option) VALIDATION CLEANING IN PLACE (CIP): • 180° Rotating spray columns • Spraying columns and nozzles installed on the strategic areas • Fully validated cycle FREEZE DRYER Freeze drying is often an important stage in the purification of products. A lot of work, whether before or after drying, can be destroyed by uneven drying, and hence/validation of freeze dryers is important DOCUMENTATION • Product specific cycle validation • Over pressure spraying system (option) Experience shows, that correct documentation can shorten the validation time and simplify the validation process. For this reason, Pharmalab has developed tests and the corresponding documentation that can streamline your validation process. STERILIZATION IN PLACE (SIP): PROJECT MANAGEMENT • PLC controlled cycle Each project is handled by a project team consisting of a project manager that coordinates communication between the customer and the rest of the project team comprising a mechanical design engineer, a quality control engineer, a validation engineer, a manufacturing engineer and a logistics engineer. Our team partners with you through site supervisión and installation, providing you with after sales service and maintenance. • F0 sterilization value • Fully validated cycle • Uniform steam penetration due to corner-less chamber Site Supervision & Qualification Team Customer Project Manager REFRIGERATION SYSTEM: • Direct expansion system: reciprocating compressor 2 Assistant Project Manager stage • Unifluid™ cooling system: single stage screw compressor Project Manager Engineering Team • Unifluid™: Patented energy efficient system Production Project Manager • Liquid Nitrogen (N2) expansion system • Hybrid system After Sales Team • CFC free refrigerants A) PRE SALES ACTIVITY ENQUIRY U.R.S. QUOTATION FORMAL ORDER VACUUM SYSTEM: • Roots blower • Dry vacuum pump (option) • Minimum vacuum: 10 µbar B) PROJECT MANAGEMENT F.A.T. PROTOCOLS DESIGN QUALIFICATION MANUFACTURING INTERNAL TESTING F.A.T. REVISION • Vane type high performance oil ring vacuum pump CHANGE CONTROL DEVIATION PRE I.Q. PRE O.Q. SITE ACCEPTANCE TEST I.Q. C) DOCUMENTATION • Design Qualification: Functional Specification, Piping & Instrumentation Diagram (P&ID), Layout Drawings, Nomenclature • Installation Qualification • Operational Qualification • Operation Mannual • Maintenance Mannual • Material Quality Test Certificates File O.Q. AUTOMATIC LOADING AND UNLOADING SYSTEMS (ALUS) ISOLATION VALVE: Unique trayless and operatorless loading • All contact parts SS316 L Serail - Pharmalab freeze dryer fully autoloading systems are engineered to maximize product handling efficiency, eliminate operator intervention and associated contamination risks and contribute to higher product quality. • Fully cleanable The tray-less shelf loaders with option of isolators for operator protection and product containment. can load all size of vials, ampoules or syringes under “built-in” HEPA filters or within isolated systems. Whether you need small or large chambers, Serail- Pharmalab has the system of choice for you. • Leak proof The CAL21 control system is 21CFR11 compliant, easy to program and contains accurate record keeping and Maintenance is an important issue for dependability : to achieve a high degree of assurance, the number and frequency ofpeople in the sterile area should be limited. On Serail Freeze Dryers, most maintenance operations can be performed from the non sterile side. THE BENEFIT OF ISOLATORS: Pharmaceutical customers who need to assure a superior degree of product protection because of high-value and expensive products or of operator protection because of toxic products (for example *cytotoxic) can rely on Serail- Pharmalab’s Isolator production systems. Integrating freeze dryers, ALUS (Automatic Loading and Unloading Systems) and isolators into one complete system delivers the best solution for the aseptic production. • King Valve • Butterfly valve • Ensures chamber condenser separation • Automatic open & close STOPPERING: Stoppering is done at the end of the drying process where vials loaded on shelves are stoppered under vacuum or under a controlled atmosphere of inert gas. • The shelf stoppering is achieved by stacking the shelves in the bottom of the chamber. • The ram device inside the chamber allows stoppering under partial or full vacuum. • The ram as well as all different attendant components are not connected to the product chamber. • A sterile bellow preventing any contamination from the ram to the chamber. SOME OF THE POSITIVES BEING: • High degree of sterility assurance • Only class “C” surrounding environment required SUB DOOR: Sub Door (Pizza Door) is designed for high vacuum and overpressure operation • Vertical sliding type meets cGMP requirements • Fully cleanable • Intelligently engineered to operate in Class A area SANITARY PIPING: uses SS 316L tubes to ensure toughness even down to cryogenic temperatures and offer high creep, stress to rupture and tensile strength. A sanitary piping specifications file will be provided that includes: - Certificate of degreasing; - Material certificate; - Hydrostatic test certificate; - Welding operator’s certificate; - Welding procedure specifications; ARCHITECTURE DETAILS CAL21 ALL SYSTEMS CAN BE VALIDATED TO THE LEVEL OFDRYER COMPLIANCE FREEZE THAT THE APPLICATION DEMANDS. SCADA (Supervisory Control And Data Acquisition) System This validatable and FDA–compliant system is developed especially for precise control and monitoring of processes for their smooth running and easy reproduction and documentation.. We utilise a colour touch-screen to select, edit and run recipes, and provide user friendly interface to monitor the events. Kryonik SCADA Systems feature fully computerizedPC supervisor and PLC controlling available with redundant backup of standard controls. Using Wonderware® or Intellution, our user-friendly system is ideal for pharmaceutical production, QA/QC and validation. Serail's IQ and OQ documentation makes validation easy and fast. The CAL21 control system is 21CFR11 compliant, easy to program and contains accurate recordkeeping documents with trending and multileveled security. All of which enhance your product quality and reproducibility. P.L.C. and PC software are in house developed by SERAIL Automation Engineering department for our Freeze dryers and all our Automatic Loading Unloading Systems. One (1) SCADA CAL 21 Control System made of a PC supervisor associated to a PLC offering automated report generation, all programmed following latest GAMP guidelines. This system allows for completely automatic Lyophilization (including freeze holding) Cleaning in Place, Sterilisation in Place and Vacuum Leak Test. Microcomputer supervision is customised package including recipe management, automatic report generation and data trending and logging. Trouble shooting is in line will be available from the SCADA level. The system includes a PLC with power supply and analogue and discrete Input and Output boards PMS level Ethernet PC Supervisor SCADA level Deskjet Printer OVERVIEW: The CAL 21 HMI/SCADA (Human Machine Interface / Supervisory Control and Data Acquisition) is a highly specialised and customised batch management system designed to meet the integrated control, information and documentation of industrial freeze dryers. CAL 21 offers three possible levels including several options as listed below. Dot matrix Printer Controlnet Modbus RS 232 Local I/O PLC level Remote I/O ( Lyophilizer ) From lower level to higher level: - PLC's level (Process control) Drive I/O ( Brushless notor / Stepper notor ) ( Loading / Unloading ) - SCADA level (Supervisory Control And Data Acquisition) - PMS level (Process Management system) CAL 21 LIFE CYCLE Cal 21 master description CAL 21 MASTER Client spec/ Cal 21 Customized version FUNCTIONAL SPECIFICATION PID/ I/O list Segments list Step list HARDWARE DESIGN SPECIFICATION Flow charts -I/Omatrix Segment list Step list SOFTWARE DESIGN SPECIFICATION I/O matrix networks SOFTWARE MODULE SPECIFICATION Sources codes Analysis Team review Master historic report Team review & Analysis Customized historic report CAL 21 DEVELOPMENTS &MODIFICATIONS SYSTEM ACCEPTANCE TESTING ( OQ ) OQ book HARDWARE ACCEPTANCE TESTING ( IQ ) IQ book SOFTWARE INTEGRATION TESTING Steps/cycles testing cycle report SOFTWARE MODULES TESTING CODE MODULES Modification or development demand Sources codes Specific networks testing (stamped) ARCHITECTURE DETAILS CAL21 ALL SYSTEMS CAN BE VALIDATED TO THE LEVEL OFDRYER COMPLIANCE FREEZE THAT THE APPLICATION DEMANDS. SCADA (Supervisory Control And Data Acquisition) System This validatable and FDA–compliant system is developed especially for precise control and monitoring of processes for their smooth running and easy reproduction and documentation.. We utilise a colour touch-screen to select, edit and run recipes, and provide user friendly interface to monitor the events. Kryonik SCADA Systems feature fully computerizedPC supervisor and PLC controlling available with redundant backup of standard controls. Using Wonderware® or Intellution, our user-friendly system is ideal for pharmaceutical production, QA/QC and validation. Serail's IQ and OQ documentation makes validation easy and fast. The CAL21 control system is 21CFR11 compliant, easy to program and contains accurate recordkeeping documents with trending and multileveled security. All of which enhance your product quality and reproducibility. P.L.C. and PC software are in house developed by SERAIL Automation Engineering department for our Freeze dryers and all our Automatic Loading Unloading Systems. One (1) SCADA CAL 21 Control System made of a PC supervisor associated to a PLC offering automated report generation, all programmed following latest GAMP guidelines. This system allows for completely automatic Lyophilization (including freeze holding) Cleaning in Place, Sterilisation in Place and Vacuum Leak Test. Microcomputer supervision is customised package including recipe management, automatic report generation and data trending and logging. Trouble shooting is in line will be available from the SCADA level. The system includes a PLC with power supply and analogue and discrete Input and Output boards PMS level Ethernet PC Supervisor SCADA level Deskjet Printer OVERVIEW: The CAL 21 HMI/SCADA (Human Machine Interface / Supervisory Control and Data Acquisition) is a highly specialised and customised batch management system designed to meet the integrated control, information and documentation of industrial freeze dryers. CAL 21 offers three possible levels including several options as listed below. Dot matrix Printer Controlnet Modbus RS 232 Local I/O PLC level Remote I/O ( Lyophilizer ) From lower level to higher level: - PLC's level (Process control) Drive I/O ( Brushless notor / Stepper notor ) ( Loading / Unloading ) - SCADA level (Supervisory Control And Data Acquisition) - PMS level (Process Management system) CAL 21 LIFE CYCLE Cal 21 master description CAL 21 MASTER Client spec/ Cal 21 Customized version FUNCTIONAL SPECIFICATION PID/ I/O list Segments list Step list HARDWARE DESIGN SPECIFICATION Flow charts -I/Omatrix Segment list Step list SOFTWARE DESIGN SPECIFICATION I/O matrix networks SOFTWARE MODULE SPECIFICATION Sources codes Analysis Team review Master historic report Team review & Analysis Customized historic report CAL 21 DEVELOPMENTS &MODIFICATIONS SYSTEM ACCEPTANCE TESTING ( OQ ) OQ book HARDWARE ACCEPTANCE TESTING ( IQ ) IQ book SOFTWARE INTEGRATION TESTING Steps/cycles testing cycle report SOFTWARE MODULES TESTING CODE MODULES Modification or development demand Sources codes Specific networks testing (stamped) AUTOMATIC LOADING AND UNLOADING SYSTEMS (ALUS) ISOLATION VALVE: Unique trayless and operatorless loading • All contact parts SS316 L Serail - Pharmalab freeze dryer fully autoloading systems are engineered to maximize product handling efficiency, eliminate operator intervention and associated contamination risks and contribute to higher product quality. • Fully cleanable The tray-less shelf loaders with option of isolators for operator protection and product containment. can load all size of vials, ampoules or syringes under “built-in” HEPA filters or within isolated systems. Whether you need small or large chambers, Serail- Pharmalab has the system of choice for you. • Leak proof The CAL21 control system is 21CFR11 compliant, easy to program and contains accurate record keeping and Maintenance is an important issue for dependability : to achieve a high degree of assurance, the number and frequency ofpeople in the sterile area should be limited. On Serail Freeze Dryers, most maintenance operations can be performed from the non sterile side. THE BENEFIT OF ISOLATORS: Pharmaceutical customers who need to assure a superior degree of product protection because of high-value and expensive products or of operator protection because of toxic products (for example *cytotoxic) can rely on Serail- Pharmalab’s Isolator production systems. Integrating freeze dryers, ALUS (Automatic Loading and Unloading Systems) and isolators into one complete system delivers the best solution for the aseptic production. • King Valve • Butterfly valve • Ensures chamber condenser separation • Automatic open & close STOPPERING: Stoppering is done at the end of the drying process where vials loaded on shelves are stoppered under vacuum or under a controlled atmosphere of inert gas. • The shelf stoppering is achieved by stacking the shelves in the bottom of the chamber. • The ram device inside the chamber allows stoppering under partial or full vacuum. • The ram as well as all different attendant components are not connected to the product chamber. • A sterile bellow preventing any contamination from the ram to the chamber. SOME OF THE POSITIVES BEING: • High degree of sterility assurance • Only class “C” surrounding environment required SUB DOOR: Sub Door (Pizza Door) is designed for high vacuum and overpressure operation • Vertical sliding type meets cGMP requirements • Fully cleanable • Intelligently engineered to operate in Class A area SANITARY PIPING: uses SS 316L tubes to ensure toughness even down to cryogenic temperatures and offer high creep, stress to rupture and tensile strength. A sanitary piping specifications file will be provided that includes: - Certificate of degreasing; - Material certificate; - Hydrostatic test certificate; - Welding operator’s certificate; - Welding procedure specifications; VALIDATION CLEANING IN PLACE (CIP): • 180° Rotating spray columns • Spraying columns and nozzles installed on the strategic areas • Fully validated cycle FREEZE DRYER Freeze drying is often an important stage in the purification of products. A lot of work, whether before or after drying, can be destroyed by uneven drying, and hence/validation of freeze dryers is important DOCUMENTATION • Product specific cycle validation • Over pressure spraying system (option) Experience shows, that correct documentation can shorten the validation time and simplify the validation process. For this reason, Pharmalab has developed tests and the corresponding documentation that can streamline your validation process. STERILIZATION IN PLACE (SIP): PROJECT MANAGEMENT • PLC controlled cycle Each project is handled by a project team consisting of a project manager that coordinates communication between the customer and the rest of the project team comprising a mechanical design engineer, a quality control engineer, a validation engineer, a manufacturing engineer and a logistics engineer. Our team partners with you through site supervisión and installation, providing you with after sales service and maintenance. • F0 sterilization value • Fully validated cycle • Uniform steam penetration due to corner-less chamber Site Supervision & Qualification Team Customer Project Manager REFRIGERATION SYSTEM: • Direct expansion system: reciprocating compressor 2 Assistant Project Manager stage • Unifluid™ cooling system: single stage screw compressor Project Manager Engineering Team • Unifluid™: Patented energy efficient system Production Project Manager • Liquid Nitrogen (N2) expansion system • Hybrid system After Sales Team • CFC free refrigerants A) PRE SALES ACTIVITY ENQUIRY U.R.S. QUOTATION FORMAL ORDER VACUUM SYSTEM: • Roots blower • Dry vacuum pump (option) • Minimum vacuum: 10 µbar B) PROJECT MANAGEMENT F.A.T. PROTOCOLS DESIGN QUALIFICATION MANUFACTURING INTERNAL TESTING F.A.T. REVISION • Vane type high performance oil ring vacuum pump CHANGE CONTROL DEVIATION PRE I.Q. PRE O.Q. SITE ACCEPTANCE TEST I.Q. C) DOCUMENTATION • Design Qualification: Functional Specification, Piping & Instrumentation Diagram (P&ID), Layout Drawings, Nomenclature • Installation Qualification • Operational Qualification • Operation Mannual • Maintenance Mannual • Material Quality Test Certificates File O.Q. AFTER SALES SERVICE ADVANTAGE SERAIL-PHARMALABFREEZE When you partner with Pharmalab your goals become ours too… and helping you reach them is our commitment. Our philosophy is to synergize design, material, function and service to ensure our Freeze Dryers are GMP compliant and exceeding expectations of quality and performance.. Chambers, shelves, door closing systems, stoppering system, condensers and all interconnections are manufactured and quality controlled in-house to minimize risk and protect against any possible outer contamination. MAINTENANCE: DRYER When building systems we strictly follow instructions and all qualification tests are carried out in the presence of the buyer prior to delivery. To ensure your system maintains its optimal value, regular maintenance is a necessity and our team is always there to work with you. For system reliability, computer-controlled systems are preprogrammed to monitor the performance of all major components. When parameters deviate from acceptable levels, the control system notifies the user of the need for maintenance. Our engineers are ready to assist you on and look directly inside the process when problems occur. Our software delivers immediate on-line, step by-step troubleshooting and documentation for repair of manufacturing equipment and process documents with trending and multileveled security. CYLINDRICAL CHAMBER: • Following PED/ASME design code • SS316 L construction • Highest level of assurance maintaining sanitary conditions • Uniform temperature distribution during SIP TRAINING: • Highest resistance to pressure: Design pressure 2.8 Bar(g) Pharmalab offers training programmes for operators and maintenance personnel tailored to the customer’s requirements. Based on the customer’s freeze dryer configuration these trainings cover design and function of the main components, for example refrigeration skid, vacuum pumps and control system as well as fundamentals of the freeze drying process. • No corners and natural drain ensures easy drainability • Light in weight for easy installation • Full door & sub-door design OUR AFTER SALES SERVICES INCLUDE: • Maintenance Contracts • Preventive Maintenance Services • Recipe Development/Cycle Development SHELVES: • OperatorTraining On & Off Site • SS316 L construction • Spare Parts and Retrofits • Surface finish - 0.6 µm or lower MODEL SPXXS • Bench top unit • Ideal for research in clinical biotech & pharmaceutical labs • Flatness: < ± 1 mm per meter • Specific baffle design for uniform temp. • Helium leak tested • ± 1° C temperature accuracy • Compact design • Flexible • Top loading system • Chamber: AISI 316L • Ice condenser coil located in the chamber: AISI 316L • 12 port manifold • Stoppering device • In-built heating system • Air cooled refrigeration system ICE CONDENSER (INTERNAL): • R404A Eco friendly refrigerant • Following PED/ASME design code • PLC operation…option • SS316 L construction • 3 channel recorder…option • Coil externally electro-polished • Mobile system……option • Faster sublimation process • Defrosting by pure steam or hot water • Uniform ice thickness • External condenser (option) FREEZE DRYING PROCESS SCADA system for process control Stoppering system Vacuum system Ice Condenser collects sublimed ice vapours from product until it is completely dry Vacuum chamber; CIP & SIP’ able Isolation valve Mechanical refrigeration/liquid N2 cooling system TABLE SP Series 0.8 1.3 2 3 5 5 7.5 11 14 19 22 33 Kg 30 30 30 70 70 120 120 120 240 240 500 500 Ice capacity (per day) Kg 15 15 15 35 35 60 60 60 120 120 250 250 Shelf area m2 0.77 1.28 1.87 3.06 4.90 4.60 7.66 11.49 14.04 18.90 22.50 33 Shelf width mm 340 340 340 680 680 1030 1030 1030 1350 1350 1500 1500 Shelf length mm 750 750 1100 750 1200 750 1860 1860 1300 2000 1500 2200 Inter shelf spacing mm 165 90 90 100 100 100 160 100 90 110 90 90 Number of shelves Nos. 3+1 5+1 5+1 6+1 6+1 6+1 4+1 6+1 8+1 7+1 10+1 10+1 Ice capacity (max) Ice vapor Dried Product Glass Vial Stoppered Chamber type Dry Frozen Product Drying Freezing Liquid TYPICAL PRODUCT PROCESSING +40 +20 Time -20 -40 -60 Freezing 100 Primary Drying Secondary Drying 0 ice Frozen interstitial material Sublimation Desorption Adsorbed “bound “water 0 % ice formed RMI Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Condenser type Std. Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Condenser type Option External External External External External External External External External External External External Overall width mm 1650 1650 1650 2300 2300 2300 2300 2300 2300 2300 2600 2600 Overall length mm 3165 3165 3415 5150 5600 5240 6000 6000 5300 5800 5300 5800 Overall height mm 2400 2400 2400 2900 2900 3000 3000 3000 3200 3200 3200 3200 Vial capacity (16 mm Ø) Nos. 2600 4300 6500 10600 17300 16100 27200 51000 49700 67300 80300 117000 Vial capacity (22 mm Ø) Nos. 1300 2200 3300 5600 8900 8600 14200 21400 26300 35200 42100 62100 Vial capacity (24 mm Ø) Nos. 1100 1900 2800 4600 7500 7000 11900 17900 22000 29800 35700 52000 FREEZE DRYING PROCESS SCADA system for process control Stoppering system Vacuum system Ice Condenser collects sublimed ice vapours from product until it is completely dry Vacuum chamber; CIP & SIP’ able Isolation valve Mechanical refrigeration/liquid N2 cooling system TABLE SP Series 0.8 1.3 2 3 5 5 7.5 11 14 19 22 33 Kg 30 30 30 70 70 120 120 120 240 240 500 500 Ice capacity (per day) Kg 15 15 15 35 35 60 60 60 120 120 250 250 Shelf area m2 0.77 1.28 1.87 3.06 4.90 4.60 7.66 11.49 14.04 18.90 22.50 33 Shelf width mm 340 340 340 680 680 1030 1030 1030 1350 1350 1500 1500 Shelf length mm 750 750 1100 750 1200 750 1860 1860 1300 2000 1500 2200 Inter shelf spacing mm 165 90 90 100 100 100 160 100 90 110 90 90 Number of shelves Nos. 3+1 5+1 5+1 6+1 6+1 6+1 4+1 6+1 8+1 7+1 10+1 10+1 Ice capacity (max) Ice vapor Dried Product Glass Vial Stoppered Chamber type Dry Frozen Product Drying Freezing Liquid TYPICAL PRODUCT PROCESSING +40 +20 Time -20 -40 -60 Freezing 100 Primary Drying Secondary Drying 0 ice Frozen interstitial material Sublimation Desorption Adsorbed “bound “water 0 % ice formed RMI Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Cylindrical Condenser type Std. Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Internal Condenser type Option External External External External External External External External External External External External Overall width mm 1650 1650 1650 2300 2300 2300 2300 2300 2300 2300 2600 2600 Overall length mm 3165 3165 3415 5150 5600 5240 6000 6000 5300 5800 5300 5800 Overall height mm 2400 2400 2400 2900 2900 3000 3000 3000 3200 3200 3200 3200 Vial capacity (16 mm Ø) Nos. 2600 4300 6500 10600 17300 16100 27200 51000 49700 67300 80300 117000 Vial capacity (22 mm Ø) Nos. 1300 2200 3300 5600 8900 8600 14200 21400 26300 35200 42100 62100 Vial capacity (24 mm Ø) Nos. 1100 1900 2800 4600 7500 7000 11900 17900 22000 29800 35700 52000