adapter CB_KPL-040F

Transcription

adapter CB_KPL-040F
Test Report issued under the responsibility of:
TEST REPORT
IEC 60950-1
Information technology equipment – Safety –
Part 1: General requirements
Report Number. .............................. :
15057193 003
Date of issue..................................... :
2013-03-25
Total number of pages ......................
13
CB Testing Laboratory ................... :
TÜV Rheinland (Shanghai) Co., Ltd.
Address ............................................ :
B1-13/F, No.177, Lane 777, West Guangzhong Road, Zhabei
District, Shanghai 200072, P.R. China
Applicant’s name ............................ :
Channel Well Technology Co., Ltd.
Address ............................................ :
No.222, Sec. 2, Nankan Rd., Lujhu Township, Taoyuan Hsien,
33855 Taiwan
Manufacturer’s name……………….: Same as applicant
Address ............................................ :
Same as applicant
Test specification:
Standard ........................................... :
IEC 60950-1:2005 (Second Edition) + Am 1:2009
Test procedure ................................. :
CB Scheme
Non-standard test method…………..:
N/A
Test Report Form No. ..................... :
IEC60950_1C
Test Report Form(s) Originator ........ :
SGS Fimko Ltd
Master TRF....................................... :
Dated 2012-08
Copyright © 2012 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting
from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the
CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description .....................:
AC ADAPTER
Trade Mark ....................................... :
Manufacturer .................................... :
Same as applicant
Model/Type reference ...................... :
KPL-xy
(x can be 040, 050, 060 or 065, denotes for output power;
y can be F, G, V, H, I, W, J, K, L, N, Q, R or M, denotes for
output voltage)
Ratings ............................................. :
Refer to report No. 15057193 001
Page 2 of 13
Report No. 15057193 003
Testing procedure and testing location:
CB Testing Laboratory:
Testing location/ address ........................... :
TÜV Rheinland (Shanghai) Co., Ltd.
B1-13/F, No.177, Lane 777, West Guangzhong Road,
Zhabei District, Shanghai 200072, P.R. China
Associated CB Laboratory:
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Tobias Yang
Approved by (name + signature) ...... :
Mark Chen
Testing procedure: TMP
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Approved by (name + signature) ...... :
Testing procedure: WMT
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Witnessed by (name + signature) .... :
Approved by (name + signature) ...... :
Testing procedure: SMT
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Approved by (name + signature) ...... :
Supervised by (name + signature) ... :
Testing procedure: RMT
Testing location/ address ........................... :
Tested by (name + signature) .......... :
Approved by (name + signature) ...... :
Supervised by (name + signature) ... :
TRF No. IEC60950_1C
Page 3 of 13
Report No. 15057193 003
List of Attachments (including a total number of pages in each attachment):
N/A
Summary of testing:
Tests performed (name of test and test clause):
•
N/A
Testing location:
All tests as described in Test Case and
Measurement Sections were performed at the
laboratory described on page 2.
Summary of compliance with National Differences
List of countries addressed:
EU Group Differences, EU Special National Conditions, FI, DE, DK, IL, KR, SI, SE, GB, AU, CA, CH, ES,
IE, NO, US
Explanation of used codes:
AU=Australia, CA=Canada, CH=Switzerland, DE=Germany, DK=Denmark, FI=Finland, GB=United
Kingdom, IE=Ireland, IL = Israel, KR=Korea, NO=Norway, SE=Sweden, ES=Spain, US=United States of
America.
The product fulfils the requirements of EN 60950-1:2006+A11:2009+A1:2010+A12:2011
TRF No. IEC60950_1C
Page 4 of 13
Copy of marking plate
N/A
TRF No. IEC60950_1C
Report No. 15057193 003
Page 5 of 13
Report No. 15057193 003
Test item particulars .................................................. :
Equipment mobility .................................................... : [x] movable [] hand-held
[x] transportable
[] stationary [] for building-in [] direct plug-in
Connection to the mains............................................ : [x] pluggable equipment [x] type A [] type B
[] permanent connection
[x] detachable power supply cord
[] non-detachable power supply cord
[] not directly connected to the mains
Operating condition ................................................... : [x] continuous
[] rated operating / resting time:
Access location ......................................................... : [x] operator accessible
[] restricted access location
Over voltage category (OVC) ................................... : [] OVC I
[] other:
[x] OVC II
[] OVC III
[] OVC IV
Mains supply tolerance (%) or absolute mains supply ± 10%
values ....................................................................... :
Tested for IT power systems .................................... : [x] Yes
[] No
IT testing, phase-phase voltage (V) ......................... : For Norway, 230V
Class of equipment ................................................... : [x] Class I [] Class II
[] Not classified
[] Class III
Considered current rating of protective device as
part of the building installation (A) ............................ :
Pollution degree (PD) ............................................... : [] PD 1
[x] PD 2
[] PD 3
IP protection class .................................................... : IPX0
Altitude during operation (m) .................................... : Up to 2000
Altitude of test laboratory (m) ................................... : < 2000
Mass of equipment (kg) ............................................ : Approx. 0.24 kg for output power 40-50W models.
Approx. 0.26 kg for output power 60-65W models
except for model KPL-065F.
Approx. 0.27 kg for model KPL-065F.
Possible test case verdicts:
- test case does not apply to the test object .................: N/A (or N)
- test object does meet the requirement .......................: P (Pass)
- test object does not meet the requirement .................: F (Fail)
Testing ..........................................................................:
Date of receipt of test item ............................................: N/A
Date(s) of performance of tests ....................................: N/A
General remarks:
TRF No. IEC60950_1C
Page 6 of 13
Report No. 15057193 003
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ................................................................ :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies)...........................: 1) Ningbo Iso Electronic Co., Ltd.
10, Chuange-ye Rd., The West of Ningbo Free
Trade Zone, Ningbo, Zhejiang, P.R. China
2) Channel Well Technology (Guangzhou) Co., Ltd.
Bld. B, Eastern Hi-tech Industrial Base, Zengjiang
Street, Zengcheng, Guangzhou, Guangdong
511300, P.R. China
General product information:
Description of change(s):
1.
2.
3.
Add alternative source of varistor as below:
- Mfg: Thinking Electronic Industrial Co., Ltd.; Typ: TVR14681
- Mfg: Nanjing Jocol Electronics Technology Co., Ltd.; Typ:TUR14D681K
Correct typing error on technical data of varistor
Name the unspecified components as “interchangeable” components
For the above described change(s) the following was considered to be necessary:
Change
Testing
Comments
1.
N/A
Approved components, higher ratings used. See appended
table 1.5.1 in bold for details.
2.
N/A
See appended table 1.5.1 in bold for details.
3.
N/A
See appended table 1.5.1 in bold for details.
Definition of variable(s):
KPL-xy
Variable:
Range of variable:
Content:
x
Can be 040, 050, 060 or
065
Denotes for output power. 040 = 40W, 050 = 50W, 060 =
60W, 065 = 65W.
y
Can be F, G, V, H, I, W, J,
K, L, N, Q, R or M
Denotes for output voltage. F = 12V, G = 13V, V = 14V, H
= 15V, I = 16V, W = 17V, J = 18V, K = 19V, L = 20V, N =
TRF No. IEC60950_1C
Page 7 of 13
Report No. 15057193 003
21V, Q = 22V, R = 23V, M = 24V.
History of amendments and modifications:
Ref. No. 15057193 001, dated 19.12.2012
Ref. No. 15057193 002, dated 05.03.2013
Ref. No. 15057193 003, dated 25.03.2013
Abbreviations used in the report:
- normal conditions
- functional insulation
- double insulation
- between parts of opposite
polarity
N.C.
OP
DI
- single fault conditions
- basic insulation
- supplementary insulation
S.F.C
BI
SI
BOP
- reinforced insulation
RI
Indicate used abbreviations (if any)
TRF No. IEC60950_1C
Page 8 of 13
Report No. 15057193 003
IEC 60950-1/Am1
Clause
Requirement + Test
Result - Remark
1.5.1
TABLE: List of critical components
P
Object/part no.
Manufacturer/
trademark
Technical data
Standard
Mark(s) of
conformity 1.
Plastic
Enclosure
SABIC Innovative SE1X
Plastics Japan L
LC
V-1 or better,
105°C,
thickness 1.5
mm min.
UL 94
UL
<Alternative>
Teijin Chemicals
Plastic
Compounds
Shanghai Ltd
V-0 or better,
115°C,
thickness 1.5
mm min.
UL 94
UL
PCB
Interchangeable Interchangeable V-1 or better,
min. 130°C
UL 94, UL 796
UL
Appliance Inlet
(CON1)
Tecx-Unions
Technology
Corporation.
TU-301-SP
10 A, 250 Vac,
70°C
IEC/EN 603201+A1, ANSI/UL
498
VDE, UL
<Alternative>
Tecx-Unions
Technology
Corporation.
TU-333
2.5 A, 250 Vac, IEC/EN 6032070°C
1+A1, ANSI/UL
498
VDE, UL
<Alternative>
RF-190
Rong Feng
Industrial Co., Ltd.
2.5 A, 250 Vac, IEC/EN 6032070°C
1+A1, ANSI/UL
498
VDE, UL
<Alternative>
SS-120
Rong Feng
Industrial Co., Ltd.
10A, 250 Vac,
70°C
IEC/EN 603201+A1, ANSI/UL
498
VDE, UL
<Alternative>
Rich Bay Co., Ltd. R-30790
2.5A, 250 Vac,
70°C
IEC/EN 603201+A1, ANSI/UL
498
VDE, UL
<Alternative>
Rich Bay Co., Ltd. R-301SN
10A, 250 Vac,
70°C
IEC/EN 603201+A1, ANSI/UL
498
VDE, UL
<Alternative>
Zhe Jiang Bei Er ST-A01-003J
Jia Electronic Co.,
Ltd.
10A, 250 Vac,
70°C
IEC/EN 603201+A1, ANSI/UL
498
VDE, UL
<Alternative>
Zhe Jiang Bei Er ST-A04-002
Jia Electronic Co.,
Ltd.
2.5A, 250 Vac,
70°C
IEC/EN 603201+A1, ANSI/UL
498
VDE, UL
<Alternative>
Supercom
Electronics Co.,
Ltd.
SC-8R
10A, 250 Vac,
70°C
IEC/EN 603201+A1, ANSI/UL
498
VDE, UL
<Alternative>
Supercom
Electronics Co.,
Ltd.
SC-14
2.5A, 250 Vac,
70°C
IEC/EN 603201+A1, ANSI/UL
498
VDE, UL
TRF No. IEC60950_1C
Type/model
Verdict
LN-1250G
Page 9 of 13
Report No. 15057193 003
IEC 60950-1/Am1
Clause
Requirement + Test
Result - Remark
Verdict
Fuse (Fuse1)
4T
XC Electronics
(Shenzhen) Corp.
Ltd.
T4.0AL, 250
Vac
IEC/EN 60127- VDE, UL
1, IEC/EN
60127-3,
ANSI/UL 248-1,
ANSI/UL 248-14
<Alternative>
5TE
XC Electronics
(Shenzhen) Corp.
Ltd.
T4.0AL, 250
Vac
IEC/EN 60127- VDE, UL
1, IEC/EN
60127-3,
ANSI/UL 248-1,
ANSI/UL 248-14
<Alternative>
Ever Island
Electric Co., Ltd.
and Walter
Electric
2010
T4.0AL, 250
Vac
IEC/EN 60127- VDE, UL
1, IEC/EN
60127-3,
ANSI/UL 248-1,
ANSI/UL 248-14
<Alternative>
Conquer
Electronics Co.,
Ltd.
PTU
T4.0AL, 250
Vac
IEC/EN 60127- VDE, UL
1, IEC/EN
60127-3,
ANSI/UL 248-1,
ANSI/UL 248-14
<Alternative>
Conquer
Electronics Co.,
Ltd.
MST
T4.0AL, 250
Vac
IEC/EN 60127- VDE, UL
1, IEC/EN
60127-3,
ANSI/UL 248-1,
ANSI/UL 248-14
<Alternative>
Littelfuse, Inc.
WickmannWerke
392
T4.0AL, 250
Vac
IEC/EN 60127- VDE, UL
1, IEC/EN
60127-3,
ANSI/UL 248-1,
ANSI/UL 248-14
Varistor (TVS1)
(after fuse and
not connected
to PE))
(Optional)
Thinking
Electronic
Industrial Co.,
Ltd.
TVR14471
300Vac/385Vdc,
Max 4500A,
85°C
IEC 61051-1,
IEC 61051-2,
IEC 61051-2-2,
ANSI/UL 1449
3rd, Annex Q of
IEC 60950-1
<Alternative>
Thinking
Electronic
Industrial Co.,
Ltd.
TVR14681
420Vac/560Vd
c, Max 4500A,
85°C
VDE, UL
IEC 61051-1,
IEC 61051-2,
IEC 61051-2-2,
ANSI/UL 1449
3rd, Annex Q of
IEC 60950-1
<Alternative>
Nanjing Jocol
Electronics
Technology Co.,
Ltd.
TUR14D471K
300Vac/385Vdc,
Max 4500A,
85°C
IEC 61051-1,
IEC 61051-2,
IEC 61051-2-2,
ANSI/UL 1449
rd
3 , Annex Q of
IEC 60950-1
TRF No. IEC60950_1C
VDE, UL
TUV, UL
Page 10 of 13
Report No. 15057193 003
IEC 60950-1/Am1
Clause
Requirement + Test
Result - Remark
Verdict
420Vac/560Vd
c, Max 4500A,
85°C
TUV, UL
IEC 61051-1,
IEC 61051-2,
IEC 61051-2-2,
ANSI/UL 1449
3rd, Annex Q of
IEC 60950-1
LE
Max. 0.47 µF,
min. 250 Vac,
100°C
IEC/EN 6038414: 2005, UL
1414
ENEC, UL
Jenn Fu
Electronics
Corporation
MPX
Max. 0.47 µF,
min. 250 Vac,
100°C
IEC/EN 6038414: 2005, UL
1414
VDE, UL
<Alternative>
Europtronic
(Taiwan) Ind.
Corp.
MPX2
Max. 0.47 µF,
min. 250 Vac,
110°C
IEC/EN 6038414: 2005, UL
1414
VDE, UL
<Alternative>
Ultra Tech Xiphi
Enterprise Co.,
Ltd.
HQX
Max. 0.47 µF,
min. 250 Vac,
100°C
IEC/EN 6038414: 2005, UL
1414
VDE, UL
<Alternative>
MKP
Hua Jung
Components Co.,
Ltd.
Max. 0.47 µF,
min. 250 Vac,
100°C
IEC/EN 6038414: 2005, UL
1414
ENEC, UL
<Alternative>
Arcotronics Italia
S.P.A
R.46
Max. 0.47 µF,
min. 250 Vac,
100°C
IEC/EN 6038414: 2005, UL
1414
ENEC, UL
Bleeder
Resistor (R2,
R3, R4, R5)
Interchangeable Interchangeable SMD type, 2.2
MΩ, 1/4 W,
Four in series
after fuse
<Alternative>
TUR14D681K
Nanjing Jocol
Electronics
Technology Co.,
Ltd.
X-Capacitor
(CX1) (X1 or
X2 type)
(Optional)
Okaya Electric
Industries Co.,
Ltd.
<Alternative>
IEC/EN 60950-1 Test within the
unit
TDK Corporation
Bridging
Capacitor
(CY1) (Y1 type)
(Optional)
CD
Max. 2200 pF,
min. 250 Vac,
125°C
IEC/EN 6038414: 2005, UL
1414
VDE, UL
<Alternative>
Murata Mfg. Co.,
Ltd.
KX
Max. 2200 pF,
min. 250 Vac,
125°C
IEC/EN 6038414: 2005, UL
1414
VDE, UL
<Alternative>
Walsin
Technology
Corp.,
AH
Max. 2200 pF,
min. 250 Vac,
125°C
IEC/EN 6038414: 2005, UL
1414
VDE, UL
<Alternative>
JYA-NAY Co.,
Ltd.
JN
Max. 2200 pF,
min. 250 Vac,
125°C
IEC/EN 6038414: 2005, UL
1414
VDE, UL
<Alternative>
Success
Electronics Co.,
Ltd.
SB, SE
Max. 2200 pF,
min. 250 Vac,
125°C
IEC/EN 6038414: 2005, UL
1414
VDE, UL
TRF No. IEC60950_1C
Page 11 of 13
Report No. 15057193 003
IEC 60950-1/Am1
Clause
Requirement + Test
Result - Remark
Verdict
Bridge Diode
(BD1)
Interchangeable Interchangeable Min. 2 A, min.
600 V
--
Test within the
unit
Ripple
Capacitor (C2)
Interchangeable Interchangeable 68-120 µF, min. -400 V, min.
105°C
Test within the
unit
Transistor (Q1)
Interchangeable Interchangeable Min. 4.5 A,
min. 600 V
--
Test within the
unit
--
Test within the
unit
Current Sensor Interchangeable Interchangeable Min. 1.8 Ω,
Resistor (R9,
min. 1/4 W,
R15, R16, R18,
SMD type
R23)
Line Choke
Sunycore
(LF1) (Optional) Electronics Co.,
Ltd.
T18*10*7
130°C
--
Test within the
unit
<Alternative>
T18*10*7
130°C
--
Test within the
unit
Line Choke
Sunycore
(LF2) (Optional) Electronics Co.,
Ltd.
T10*6*5+C
130°C
--
Test within the
unit
<Alternative>
T10*6*5+C
130°C
--
Test within the
unit
Transformer
Channel Well
(T1)
Technology Co.,
Ltd.
(for output
voltage 12-16V
used)
PQ-2620-12
Class B (GH130)
Applicable parts Accepted by
of IEC 60950-1 TÜV
and according to Rheinland
IEC 60085
(for output
Channel Well
voltage 17-24V Technology Co.,
used)
Ltd.
PQ-2620-17
Class B (GH130)
Applicable parts Accepted by
of IEC 60950-1 TÜV
and according to Rheinland
IEC 60085
Bobbin (for T1) Chang Chun
Palstics Co., Ltd.
T375J
Phenolics,
150°C,
V-0
UL 94
TRW(B)
Triple insulated Great Leoflon
wire (for T1
Industrial Co., Ltd.
secondary
winding)
130°C
IEC/EN 60950-1, VDE, UL
UL 2353
Sleeving (for
T1)
200°C, VW-1
UL 224
Channel Well
Technology Co.,
Ltd.
Channel Well
Technology Co.,
Ltd.
Great Holding
TFL
Industrial Co., Ltd.
TRF No. IEC60950_1C
UL
UL
Page 12 of 13
Report No. 15057193 003
IEC 60950-1/Am1
Clause
Requirement + Test
Result - Remark
Verdict
Optocoupler
(IC1)
Lite-On
Technology
Corporation
LTV-817
Dti ≥ 0.4 mm,
Int. cr > 4.0
mm,
Ext. cr = 8.0
mm,
110°C
DIN EN 607475-2, IEC/EN
60950-1,
UL 1577
VDE, Fimko,
UL
<Alternative>
Cosmo
Electronics
Corporation
K1010
Dti = 0.5 mm,
Int. cr = 5.3
mm,
Ext. cr = 8.0
mm, 110°C
DIN EN 607475-2, IEC/EN
60950-1,
UL 1577
VDE, Fimko,
UL
<Alternative>
Toshib Corp.
Semiconductor
TLP781/TL781F
Dti = 0.5 mm,
Int. cr = 6.0
mm,
Ext. cr = 7.7
mm, 110°C
DIN EN 607475-2, IEC/EN
60950-1,
UL 1577
VDE, Fimko,
UL
<Alternative>
Everlight
Electronics Co
Ltd
EL817
Dti = 0.5 mm,
Int. cr = 6.0
mm,
Ext. cr = 7.7
mm, 110°C
DIN EN 607475-2, IEC/EN
60950-1,
UL 1577
VDE, Fimko,
UL
<Alternative>
Fairchild
Semiconductor
FOD817
Dti ≥ 0.4 mm,
Int. cr ≥ 5.0
mm,
Ext. cr ≥ 7.0
mm, 110°C
DIN EN 607475-2, IEC/EN
60950-1,
UL 1577
VDE, Fimko,
UL
Insulator sheet
ITW Electronics
Components/Pro
ducts (Shanghai)
Co., Ltd.
FORMEX GK-17
V-1 or better,
thickness 0.43
mm min.
UL 510
UL
<Alternative>
YI-HSN Plastech
Co Ltd.
YIMEX PP-17
V-1 or better,
thickness 0.43
mm min.
UL 510
UL
Output cable
Interchangeable Interchangeable 16 or 18AWG,
300V, 80°C,
FEP, PTFE,
PVC, TFE,
neoprene,
polyimide or
marked VW-1
UL 758
UL
Thermal pad for Interchangeable Interchangeable V-2 or better
C2 (for 60W
and 65W
models)
UL 94
UL
Interchangeable Interchangeable V-2 or better
UL 94
UL
Rubber pad
(under PCB)
TRF No. IEC60950_1C
Page 13 of 13
Report No. 15057193 003
IEC 60950-1/Am1
Clause
Requirement + Test
Result - Remark
Verdict
Supplementary information:
1. An asterisk indicates a mark that assures the agreed level of surveillance.
2. In Optocoupler technical data column, where “di” means distance through insulation, “int.” means internal
creepage distance, “ext.” means external creepage distance.